RC-17-1482t
s .
a. ,
Miami Shores Village RECEIVED
Building Department
10050 NE 2"d Ave. 9 1017
o p Miami Shores, FL 33138
305-795-2204 / Fax 305-756-8972
NOTICE TO MIAMI SHORES BUILDING DEPARTMENT OF EMPLOYMENT AS SPECIAL
INSPECTOR UNDER THE FLORIDA BUILDING CODE.
I (We) have been retained by Imburgia Construction Co. to perform special inspector services under the Florida
Building Code 5th Edition (2014) and Miami Dade County Administrative Code at the Butler Residence: 10007 NE 4th Avenue Miami Shores, FL
project on the below listed structure as of October 23, 2017 (date). I am a registered
architect/professional engineer licensed in the State of Florida.
Process Number; RC17-1482
Special Inspector for Reinforced Masonry, Section 2122.4 of the FBC 5th Edition (2014)
Miami Dade County Administrative Code, Article II Section B-22 Special Inspector for
Trusses > 35 ft. long or 6 ft. high
Steel Framing and Connections welded or bolted
X Soil Compaction
Precast Attachments
Roofing Applications, Lt. Weight. Insul. Conc.
Other
Note: Only the marked boxes apply.
The following individual(s) employed by this firm or me is authorized representative to perform
inspection*
I. Dave Walker 2. Thurston Lovett
3. Daemion Black 4. Luis Rodriguez
Special inspectors utilizing authorized representatives shall insure the authorized representative is qualified by
education or licensure to perform the duties assign by Special Inspector. The qualifications shall include licensure as a
professional engineer or architect: graduation from an engineering education program in civil or structural engineering;
graduation from an architectural education program; successful completion of the NCEES Fundamentals Examination;
or registration as building inspector or general contractor.
I (we) will notify the Miami Shores Building Department of any changes regarding authorized personnel
performing inspection services.
I (we), understand that a Special Inspector inspection log for each building must be displayed in a
convenient location on the site for reference by the Miami Shores Building Department Inspector. All
mandatory inspections, as required by the Florida Building Code, must be performed by the Miami Shores
SC-
Building Department .Inspections performed by the Special Inspector hired by the owner are in addition to
andatory inspections performed by the department. Further, upon completion of work under each
Bgng Permit, I will submit to the Building Inspector at the time of the final inspection the completed
Qj •'•G•NS inspbgtion l'og form and a sealed statement indicating that, to the best of my knowledge, belief and
fes'sio*l judgment those portions of the project outlined above meet the intent of the Florida Building
Code acid are -in substantial accordance with the approval plans.
Engineer/Architect
SZPName Robert H. Schuler, P.E.
C,Q'•. F LI olL99ance d eale Print
Si0',I ate. 111/06/17 Address 1820 NE 144th Street, N. Miami, FL 33181
10 00
Oh Miami Shores Village
Building Department
10050 NE 2"d Ave.
R Miami Shores, FL 33138
305-795-2204 / Fax 305-756-8972
NOTICE TO MIAMI SHORES BUILDING DEPARTMENT OF EMPLOYMENT AS SPECIAL
INSPECTOR UNDER THE FLORIDA BUILDING CODE.
I (We) have been retained by Imburgia Construction Co. to perform special inspector services under the Florida
Building Code 5th Edition (2014) and Miami Dade County Administrative Code at the Butler Residence: 10007 NE 4th Avenue Miami Shores, FL
project on the below listed structure as of October 23, 2017 (date). I am a registered
w architect/professional engineer licensed in the State of Florida.
Process'Number: RC17-1482
Special Inspector for Reinforced Masonry, Section 2122.4 of the FBC 5th Edition (2014)
Miami Dade County Administrative Code, Article II Section 8.22 Special Inspector for
Trusses > 35 ft. long or 6 ft. high
Steel Framing and Connections welded or bolted
X Soil Compaction
Precast Attachments
Roofing Applications, Lt. Weight. Insul. Conc.
Other
Note: Only the marked boxes apply.
The following individual(s) employed by this firm or me is authorized representative to perform
inspection*
I. Dave Walker 2. Thurston Lovett
3. Daemion Black 4. Luis Rodriguez
Special inspectors utilizing authorized representatives shall insure the authorized representative is qualified by
education or licensure to perform the duties assign by Special Inspector. The qualifications shall include licensure as a
professional engineer or architect: graduation from an engineering education program in civil or structural engineering;
graduation from an architectural education program; successful completion of the NCEES Fundamentals Examination;
or registration as building inspector or general contractor.
I (we) will notify the Miami Shores Building Department of any changes regarding authorized personnel
performing inspection services.
I (we); understand that a Special Inspector inspection log for each building must be displayed in a
convenient location on the site for reference by the Miami Shores Building Department Inspector. All
mandatory inspections, as required by the Florida Building Code, must be performed by the Miami Shores
Building Department .Inspections performed by the Special Inspector hired by the owner are in addition to
datory inspections performed by the department. Further, upon completion of work under each
A
Sc 39PI Permit, l will submit to the Building Inspector at the time of the final inspection the completed
oMpecitop log form and a sealed statement indicating that, to the best of my knowledge, belief and
Oprosiorial jlgtnent those portions of the project outlined above meet the intent of the Florida Building
CC : b and ark substantial accordance with the approval plans.
Engineer/Architect
F
Natne Robert H. Schuler, P.E.
t led Print
AiQ•' ate,. /06/17 Address 1820 NE 144th Street, N. Miami, FL 33181
QFES S14
a
MIAMI-
Department of Regulatory and Economic Resources
DADE
Impact Fee Assessment
Process Number: M2017013230-0
Folio: 1132060170490
Fee Payer:
f
Batch: Collection Number:
Site Address: 10007 NE 4 AVE`
i
Assessment Date: 06/19/2017
Disclaimer Note: ROAD/F/RE/POUPKS impact fees
will increase on 101112017
Online Payment available at:
https.lAvww8.miamidade.gov/apps/rerlimpactFeesPayments/default.aspx •
Payment can be made by Credit Card, Cash, Check or Cashiers's Check
Payable to Miami Dade County
Fee Type iDist Id!Category $Cat Category Description Units Fee IExtended Amount Deferred
S Code 'Sufix = __• ...-,.__.__.. :Amount
AREA i $0.00
1.0 X5002 100 1UNIT SIZE (SQ FT) 608 $0.9180 i $558.14
Assessment Total Amount: $558.14
Deferral Amount: $0.00
Current Balance Due: $558.14
Report run on: June 19, 2017 12:36 PM Page 1 of 1
FC.".., .w,•,K,o f,P --
engineering inc
September 18, 2017
Florida Department of Health
in DADE COUNTY
1725 NW 167 St, Opa Locka, FL 33056
Re: Butler Residence
10007 NE 4th Ave Miami Shores Florida
Application Document No: 1300327
Attn: Plan Reviewer
Dear Sir or Madam,
Please find building comments below:
Plumbing:
www.ari)e-enci.com
1. On the plumbing site plan (Sheet P-100), correct the following:
Drainlines cannot have greater than 10' difference in length.
R: Please see revised drawing, now drain field corrected.
If you may'have furthkr questions, please contact us at your earliest convenience.
Sincerely,
Am itis R ri
ARPE Ene' ee
P.E
Inc.
0:\17-0407 CRISTINA BUTLER RESIDENCE RENOVATION ADDITION (MRS. BUTLER)\DOCS\RTC- 09-18-17.doc —
2655 Le Jeune Road Suite 1109, Coral Gables, Florida 33134 Ph 305.444.9809 Fax 305.444.9827
Wechanical >Electrical >Plumbing > Fire Protection >C.A. >LEED Certification
0*0:0
0000..
0..
0000
0
000
0000 000.0
0000.
0000..
0000
0000
0
0 •
0000 0000.
0000
o::::0
0::::
0 0
00 •0 000000
000000
00.0• 0
0000
0000..
00
0 h
0 . 000
00
0:\17-0407 CRISTINA BUTLER RESIDENCE RENOVATION ADDITION (MRS. BUTLER)\DOCS\RTC- 09-18-17.doc —
2655 Le Jeune Road Suite 1109, Coral Gables, Florida 33134 Ph 305.444.9809 Fax 305.444.9827
Wechanical >Electrical >Plumbing > Fire Protection >C.A. >LEED Certification
GD KL'IEGER, INC.
1909 Harrison St. #204
Hollywood, FL
954)923-2111
GERSHON KLIEGER, PE #36109
Concrete Beam
Project Title:
Engineer:
Project Descr:
Project ID:
Printed: 18 JUL 2017, 8:22AM
File - CMJsersIG 0QCUME-11ENERCALC Data Files6xamp1es.ec6
ENERCALC, INC. 1983-2.017, Quil,J 10.17.6.29, Ver:10.17.6.29
Description BUTLER RESIDENCE- 2 STORY ADDITION - ROOF 8"x36" CONC BEAM (L=10FT) EAST & WEST SIDES
CODE REFERENCES
Calculations per ACI 318-05, IBC 2006, CBC 2007, ASCE 7-05
Load Combination Set : ASCE 7-10
Material Properties
fc
112 =
3.0 ksi Phi Values Flexure 0.90
fr = fC 7.50 = 410.792 psi Shear : 0.750
y) Density = 145.0 pcf Ili = 0.850
LIWt Factor = 1.0
Elastic Modulus = 3,122.0 ksi Fy - Stirrups 60.0 ksi
fy - Main Rebar = 60.0 ksi E - Stirrups = 29,000.0 ksi
E - Main Rebar = 29,000.0 ksi Stirrup Bar Size # 3
Number of Resisting Legs Per Stirrup = 2
D(2 5) L(3.5)
I
I
8 in
00000
Cross Section & Reinforcing Details
Rectangular Section, Width = 8.0 in, Height = 36.0 in
Span #1 Reinforcing....
245 at 3.750 in from Bottom, from 0.0 to 13.330 ft in this span
Applied Loads
Beam self weight calculated and added to loads
Load for Span Number 1
Uniform Load : D = 0.020, L = 0.030 ksf, Tribulary Widlh = 10.50 ft, (ROOF)
Point Load : D = 2.50, L = 3.50 k Q 8.0 ft, (COL)
DESIGN SUMMARY
MaxinlUn-I Bending Stress Ratio =
Ratio =
0.272 : 1 Maxirnurn Deflection
Section used for this span Typical Section Max Downward Transient Deflection
Mu Applied
37977-18 .
23 740 k -ft Max Upward 'Transient Deflection
Mn ' Phi Allowable
Location of maximum on span 6.557 fl
Max lJpward Total Deflection
Span # where maximum occurs Span # 1
Vertical Reactions
Service loads entered Load Factors will be fo'r calculatdris:;'
Support notation Far left is #1
Load Combination
appliel
Support 2
Overall MAXIMUM 5.275
1.800 2.700
D Only 3.000 4.500
t +D+L 5.275
MaxinlUn-I Bending Stress Ratio =
Ratio =
0.272 : 1 Maxirnurn Deflection
Section used for this span Typical Section Max Downward Transient Deflection
Mu Applied
37977-18 .
23 740 k -ft Max Upward 'Transient Deflection
Mn ' Phi Allowable 87.434 k. -ft Max Downward Total Deflection
Location of maximum on span 6.557 fl
Max lJpward Total Deflection
Span # where maximum occurs Span # 1
Vertical Reactions Support notation Far left is #1
Load Combination Support 1 Support 2
Overall MAXIMUM 5.275 8.875
Overall MINinlum 1.800 2.700
D Only 3.000 4.500
t +D+L 5.275 8 875
IR +Da0.7501- 4.706 7 781
r 0 60D 1,800 2 700
L Only 2.275 4 375
Shear Stirrup Requirements
Between 0.00 to 8,40 ft. Vu < PhiVc/2, Req'd Vs = Not Reqd 11.5 6 ?, use stirrups spaced at 0.000 in
r
Between 8.42 to 9.98 ft. PhiVc/2 < Vu <= PhiVc. Req'd 'Vs = Min 11 5 6.1 use stirrups spaced at 16 000 In
0.001 in Ratio = 81437 -36
0.000 in Ratio = 0 <360
0.003 in Ratio = 37977-18 .
0.000 in Ratio= 999-18
w GD KLIEGER, INC. Project Title.
1909 Harrison St. #204 Engineer
1 Hollywood, FL Project Descr
P:(954)923-2111
GERSHON KLIEGER, PE 436109
Steel Column File=C:ItlserslGID000ME-11ENEI
i; ENERCALC, INC. 1J83-2017,
Description: BUTLER RESIDENCE- 2 STORY ADDITION - ROOF 8"06" CONC. BEAM SUPPORTING STEEL COLLI
Code References
Calculations per AISC 360-05, IBC 2006, CBC 2007, ASCE 7-05
Load Combinations Used : ASCE 7-10
General Information
Steel Section Narne : HSS6x6x114
Analysis Method Allowable Strength
Steel Stress Grade
Fy : Steel Yield 46.0 ksi
E : Elastic Bending Modulus 29,000.0 ksi
Project ID:
No. 36109
STATE OF
Overall Column Hecht ,g'O,SfN ON•A 11*: ,
Top & Bottom Fixil "Fop & Bottom PinriPdofrrfIll rt 0
Brace condition for deflection (buckling) along columns:
X -X (width) axis :
Fully braced against buckling along X -X Axis
Y -Y (depth) axis :
Fully braced against buckling along Y -Y Axis
Applied Loads
Column self weight included 171 180 lbs ' Dead Load Factor
AXIAL LOADS.
ROOF. Axial Load at 9.0 ft, Xecc = 2.0 in, Yecc = 2.0 in, D = 8.0, L = 8.0 k
DESIGN SUMMARY
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio = 0.2621 : 1
Load Combination D+L
Location of max.above base 8.940 ft
At maximum location values are
Pa . Axial 16.171 k
Pn I Omega Allowable 144.335
Ma -x : Applied 2.649 k ft
Mn -x / Omega: Allowable 25.709 k -ft
Ma -y: Applied 2.649 k -ft
Mn -y / Omega Allowable 25.709 k -ft
PASS Maximum Shear Stress Ratio = 0.007258 1
Load Combination i D i L
Location of max above base 0.0 ft
At maximum location values are
Va : Applied 02963 k
Vn!Omega Allowable 40.82.6 k
Service loads entered. Load Factors will be applied for calculations.
Maximum Load Reactions . .
Top along X -X
Bottom along X -X
Top along Y -Y
Bottom along Y -Y
Maximum Load Deflections ..
Along Y -Y -0.02912 i1n• eal
for load combination : a-D.r4.• • • •
Along X -X -0.02912 m *ai"
for load combination :+De L• • • •
0.2.963 k
0.2963 k
0 2963 k.
0.2963 k
5-ZW5 above base.'
5.259 f1 abovepjV. .