Loading...
REV-18-1146h/ E -OOV-1 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION BUILDING ELECTRIC E0 /ROOFING zkDk118— itg6FBC201- 1 Master Permit No. 1- C H97— Sub Permit No. 91-x.3 REVISION 0 EXTENSION RENEWAL PLUMBING MECHANICAL PUBLIC WORKS CHANGE OF CANCELLATION SHOP CONTRACTOR DRAWINGS JOB ADDRESS: A'L 40 City: Miami Shores 'County: Miami Dade Zip: Folio/Parcel#: l 32-06 --0 17014-10 Is the Building Historically Designated: Yes NO r Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Address /'Ono l City: /W! Q.,(- I t Tenant/Lessee Name: 14/ ,Ail e i- State: one#: ne#: Email: CONTRACTOR: Company Name: U Phone#: Address: l i'zx '4%F 4---e- City: f iuw( SpIt!/ e eS Stater Zip: 3 3 % - Qualifier Name:a44s e l (, , 0 V Phone#: 3c4 - State Certification or Registration #:< C' G / / j 6 C Certificate of Competency # P", ek— V DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ Square/Linear Footage of Work: 8 'C z— Type of Work: Addition Alteration New Repair/Replace ElDemolition Description of Work: UAP lLi O b l FI E 0% t 1 1 M `t r J d Q /i K,," l ,rr 7-,oA4,t/ G[ V Specify color of color thru tile: Submittal Fee $ Permit Fee $ Scanning Fee $ l Radon Fee $ Technology Fee Structural Reviews $ Revised02/24/2014) c CCF $_ DBPR $ Training/Education Fee $ CO/CC $ _ Notary $ Double Fee $ _ Bond $ TOTAL FEE NOW DUE $ g-4. C53 OBENOUR ROOF 1 NG, SHEET METAL Sc SUPPLY CO. OFFICES: 159 N.E. 97"' STREET MIAMI SHORES, FLORIDA 33138 305) 757-2612 - (305) 757-7861 FAX (305) 758-8484 Family owned and operated since 1929" WAREHOUSE: 7357 N.W. MIAMI COURT MIAMI, FLORIDA 33150 Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In th absence of such posted notice, the inspectio .1 not be approv and a reinspection fee will be charged. natur Signat OWNER or AGENT The foregoing instrument was acknowledged before me this X7 of 20 % by Nf tc k e who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: CONTRACTOR Th4toregoing instrument was acknowledged before me this ppC> (> c27 day of (( 20 /F by 1A M d k enc' oy who is personally known to as me or who has produced identification and who did take an oath. NOTARY Sign: Sign:--li'` nn' Print: Print: N " CATHERINE A. DUF I Seal: i Zg,`; NotaryPublic- StateofFlorida Seal: t'o"aY;, CATHER!NEA.DUFFIN Commission k GG 104296 = .+ ^ Notary Public - State of Florida My Comm. Expires May 14, 2021 Commission p GG 104296 FOFr`` •• BondedthroughNational No ryAssn. ';9, rR Y;• My Comm. Expires May 14,2021 cndsd1112= aq Ag;, APPROVED BY Revised02/24/2014) Plans Examiner Structural Review as Zoning Clerk OBENOUR ROOF I NG, SHEET METAL Sc SUPPLY CO. OFFICES: 159 N.E. 97"' STREET MIAMI SHORES, FLORIDA 33138 305) 757-2612 • (305) 757-7861 FAX (305) 758-8484 WAREHOUSE: 7357 N.W. MIAMI COURT MIAMI, FLORIDA 33150 Family owned and operated since 1929" 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1525 000* HIGH -VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION . 0000' Florida Building Code 5th Edition (2014) . • ... • High -Velocity Hurricane Zone Uniform Permit Application Form*:::: 0000 0000 INSTRUCTION PAGE • • • • • • 0000 0000.. COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PER1M 0 • APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Attachments Required 0. • 0 • 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 00 0 ATTACHMENTS RFOUIRFn• 1. Permit Application Form See List Below pplicationEPresEcriptiveBUR-RAS A,B,C 1,2,3,4,5,6,7 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 6. Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS RFOUIRFn• 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Miami Shores vi-oage APPROVED I BY 0000.. 0000.. 0000.. 0000. 0000. 0000.. 0000.. 0000.. ke - i (qr,,,; DATE 701NI iG DEPT V11TH Al L FFnF'iZAL 15.36 FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) i Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to Licenscgm Agreement. No further reproductions authorized. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) ' .... High -Velocity Hurricane Zone Uniform Permit Application fte 0 r Section A (General Information) • • • • "" Master Permit No. ...... Process Na ' ' D O •••••• Contractor's Name . • • Job Address d N S d k f S: 0696: .. . ROOF CATEGORY 1 Low Slope Mechanically Fastened Tile Mortar/Adhesive Set Tiles 1 Asphaltic Shingles Metal Panel/Shingles Wood Shingles/Shakes 1 1 Prescriptive BUR -RAS 150 1 ROOF TYPE 1XNewroof Repair Maintenance Reroofing Recovering 1 ROOF SYSTEM INFORMATION 1 Low Slope Roof Area (SF)Steep Sloped Roof AREA (SSF) Total (SF) 7 1 1 i Section B (Roof Plan) 1 Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1 1 1 1 1 1 1 1 1 i F 1 1 1 I i 1 1 Le 3 EV i 1 FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.37 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun g, 2015 10:32:12 AM pursuant to LicenseAgreement. No further reproductions authorized. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) ."". 0000.. High -Velocity Hurricane Zone Uniform Permit Application Forlb. "' • • 1 ' 1 .00.00 00 6 00000 6600.. • 1 0000.. Section C (Low Slope Application) Top Ply F ener/Banding Materiaj:• • • • . ."". S ' 1 F 1... • Fill in specific roof assembly components and identify • • • • 6 • 1 manufacturer 00000 0000.. • 1 (If a component is not used, identify as "NA") Surfacing: • • ; • • • " ; ..: . Fastener Spacing for Anchor/Base.$tyea Attachment:* 1 System Manufacturer. G/ • 6 ' . 6 Fosse* 1 — Field: t_" oc @ Lap, # Rows @ .0i. 0 " oc "" • r. .. r , 1 Product Approval No.: / l0)_ Q • D' Perimeter: _" oc @ Lap, # Rows' aGS _ b • • 1 1 Design Wind Pressures, From RAS 128 or Calculations: Corner: " oc @ Lap, # Rows @ " oc 11 1 P1: P2:— %/ ' P3— /88. a Number of Fasteners Per I ' lation Board: 1 11 Max. Design Pressure, from t),ie eafic product Field Perimeter Corner 1 1 approval system:_ rill, Illustrate Components Noted and Details as Applicable: 11 1Deck: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, 1Continuous Cleat, Cant Strip, Base Flashing, CounterFlashing, W 19 11 Type: 1 I 1 0 !r Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base 11Gauge/Thickness: ` Flashing, Component Material, Material Thickness, Fastener 1 1 Slope: { k Ff Type, Fastener Spacing or Submit Manufacturers Details that 1 Z--- mply with RAS 111 and Chapter 16. 1 1 Anchor/Base Sheet & No. of Ply(s): J,r< t t m . SQ 11T Anchor/Base Sheet Fasten r/Bondin Mat ial: 9 dY6dir r " t'Q 6Rl / Insulation Base Layer. ISa C tiQ Nt Yar 1 N ti! Y S a 1 Base Insulation Size and Thickness: Par pet 1 d Height YVooA 1 Base InsulationFastene /Bonding Material: I mZ F f 131Y X11_ T.l A t t Asn- A .l f -- yam" i 1 1 v T a - e ` ip•iC4 yfer 1 1 Top Insulation Layer: NIA. — FT. 1 1 1 Top Insulation Size and Thickness: ;P4 YI 004 1 Mean 1 1 Top Insulation Fastener/Bonding Material: Roof 1 1 Height 1 1 Base Sheet(s) & No. of Ply(s)-& Yt S vP.rr 1 1 1 1 Base Sheet Fa tener/Bonding Material: 1 1 Lot)u Ia td 1 1 Ply Sheet(s) & No. of Ply(s): P %a, a Z G 1 1 1 1 Ply heet Fastener/Bofi din Material: 1 j_ 1 Top Ply: _ P A I a 1 1 15.38 FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 1 1 1 I 1 1 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); acecssed by Eliezer Palacio on !un g, 2015 10:32:12 AM pursuant to UcenseAgreement. No further reproductions authorized. MIAMF E MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, R40" 1% DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miagi, Fjt%da 33171-t414 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F f786) 311-2:n NOTICE OF ACCEPTANCE (NOA) WWW. IID'alntaade.Eov/economy CAF 0000 0000 I Campus Drive ' 0000 ` `. • • • ` Parsippany, NJ 07054 • • • • • 0000 SCOPE: • • • 0000.. • This NOA is being issued under the applicable rules and regulations governing the use;of co;struc4Q1l .:. materials. The documentation submitted has been reviewed and accepted by Miami-D4le Mnty ITER - Product Control Section to be used in Miami Dade County and other areas where allowed bythe • ` • • • Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAFr-. Ruberoid® Modified Bitumen Roof System for Wood Decks., LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 14-1030.02 and consists of pages 1 through 67. The submitted documentation was reviewed by Jorge L. Acebo., J M ALMI•DADE COU mI NOA No.: 15-1020.01 Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 1 of 67 0000•. 0000•• 0000•• 0000. V••• 0000. 0000.. OBENOUR ROOF 1 NO, SHEET METAL Sc SUPPLY CO. OFFICES: 1594J.E. 97th STREET MIAMrSHORES,^OFVDA 33138 309)7SI-26120757-7861 fAX (305)•751-%84 Family owned and operated since 1929" WAREHOUSE: 7357 N.W. MIAMI COURT MIAMI, FLORIDA 33150 e APPROVED ASSEMBLIES Membrane Type: SBS Deck Type II: Wood, Insulated Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type A(1): All insulation layers are adhered to a mechanically attached anctorsheet. ' • • • •' Membrane is subsequently fully adhered to insulation. • • • • • •. All General and System Limitations shall apply. Fire Barrier: FireOut— Fire Barrier Coating, VersaShield Fire -Resistant Roetty&4 Protetribfl• optional) or or VersaShield' Solo" Fire -Resistant Slip Sheet. 666* "" Anchor sheet: GAFGLAS' #80 Ultima"' Base Sheet, GAFGLAS® Stratavent` Na11'able Venting Base Sheet, Ruberoid® 20 Smooth, Ruberoid® HW Smooth or3esfNeid® HW 25 Smooth base sheet mechanically fastened to deck as described belo'W • •.:. Fastening GAFGLAS® Ply 4, Tri -Ply® Ply 4 Ply Sheet, GAFGLAS® Flex Ay"" 6, . ".' • Option #1: GAFGLAS' #75 Base Sheet, Tri -Ply® #75 Base Sheet or any of above anchor ' sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. Maximum Design Pressure —45 psf. See General Limitation #7) Fastening GAFGLAS® Ply 4, Tri -Ply® Ply 4 Ply Sheet, GAFGLAS' F1exPly' 6, Option #2: GAFGLAS' #75 Base Sheet, Tri -Ply' #75 Base Sheet or any of above anchor sheets attached to deck with Drill-TecT" #12 Fastener, Drill- TecT" # 14 Fastener or Drill -Tec" XHD Fastener and Drill -Tec' 3" Steel Plate, Drill -Tec" AccuTrac' Flat Plate or Drill- TecT" AccuTrac® Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. Maximum Design Pressure —45 psf. See General Limitation #7) Fastening GAFGLAS® F1exP1yT" 6, GAFGLAS® #75 Base Sheet, Tri -Ply' #75 Base Sheet or Option #3: any of above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. Maximum Design Pressure —52.5 psf. See General Limitation #7) Fastening GAFGLAS' #80 UltimaT Base Sheet, Ruberoid® 20 Smooth, Ruberoid' Mop Option #4: Smooth base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. Maximum Design Pressure —60 psf. See General Limitation #7) Fastening GAFGLAS® #75 Base Sheet, Tri -Ply® #75 Base Sheet or any of above anchor Option #5: sheets attached to deck with Drill -Tec' #12 Fastener, Drill -Tec' #14 Fastener or Drill-TecT" XHD Fastener and Drill -Tec' 3" Steel Plate, Drill -Tec— AccuTrac' Flat Plate or Drill -Tec" AccuTrac® Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. Maximum Design Pressure —60 psf. See General Limitation #7) Mwrti•m ne couNrir NOA No.: 15-1020.01 Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 9 of 67 Fastening Any of above anchor sheets attached to deck approved annular ring shank nails Option #6: and 3" inverted Drill -Tec' insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. Maximum Design Pressure —60 psf. See General Limitation #7) Fastening GAFGLAS' #75 Base Sheet, Tri -Ply' #75 Base Sheet or any of above anchor Option #7: sheets attached to deck with Drill -Tec'" #12 Fastener, Drill -Tec— #14 Fastener or Drill -Tec" XHD Fastener and Drill -Tec' 3" Steel Plate, Drill-'Jec'.AccuTrac"". 666 Flat Plate or Drill -Tec" AccuTrac' Recessed Plate installed 8`6,c *44 rows.* One row is in the 2" side lap. The other rows are equally spaced•atproximatel'9 ; o.c. in the field of the sheet. • • • • • • Maximum Design Pressure —75 psf. See General Limitation #7J' • • 6666 6666 6666 One or more layers of any of the following insulations.666 6669. 6. Insulation Layer Insulation Fastened' • • Fastener666. 6. Table 3) :":': Density/ft' 6 EnergyGuard" Polyiso Insulation, EnergyGuard" Polyiso RA Insulation, :... :. EnergyGuard`" Polyiso RN Insulation, EnergyGuard" RA Composite Polyiso Iifwht4)n * 6 6 6 Minimumxl:'_' thickN/A PQ/A • 6 Structodek' High Density Fiber Board, EnergyGuardT" Perlite Recover Board Minimum 1/2" thick N/A N/A EnergyGuard'" Perlite Roof Insulation Minimum 3/" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF,requires either.-a•ply of GAFGLAS'Stratavene Perforated VentingmBase Sheet laid,dry-or_a-layer..of EnergyGuard'" Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Base Sheet: (Optional) Install one ply of GAFGLAS' #75 Base Sheet, Tri -Ply' #75 Base Sheet, GAFGLAS® #80 Ultima" Base Sheet, GAFGLAS® Ply 4, Tri -Ply® Ply 4 Ply Sheet GAFGLAS® F1exPly'" 6, Ruberoid' Mop Smooth, Ruberoid' Mop Smooth 1.5, Ruberoid® Mop Plus Smooth, Ruberoid® 20 Smooth, Ruberoid® HW Smooth or Ruberoid® HW 25 Smooth directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. (See General Limitation #4). OR GAFGLAS Stratavent® Perforated Venting Base Sheet loose -laid dry. Ply Sheet: (Optional, required over GAFGLAS° Stratavent® Perforated Venting Base Sheet loose -laid dry.)One or more plies GAFGLAS® Ply 4, GAFGLAS® FlexPly`" 6, GAFGLAS® #80 Ultima" Base Sheet, Ruberoid' Mop Smooth, Ruberoid' Mop Smooth 1.5, Ruberoid' Mop Plus Smoot4,.Ruberoid' 20'Smooth adhered.ina full. mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. NOA No.: 15-1020.01 Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 10 of 67 Membrane: One or more plies of Ruberoid® 20 Smooth, Ruberoid® 30 Granule, Ruberoid` EnergyCap'" 30 Granule FR, Ruberoid' 30 Granule FR, Ruberoid 30 Plus Granule FR, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid® Mop Plus Smooth, Ruberoid Mop Granule FR, Ruberoid Mop Granule, Tri -Ply' SBS Granule Cap Sheet, Intec Flex PRF , Ruberoid® Mop Plus Granule, Ruberoid® Mop Plus Granule FR fully adhered in a full mopping of approved asphalt applied within the EVT range and at a rate -of 20110 lbs./sq. .... Surfacing: Optional on granular surfaced membranes; required for sn?outb Membrgngt.. Chosen components must be applied according to manufacttwei 6applitatibn, instructions. All coatings must be listed within a current N&A : • • 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively iiia flood%Q4.' 2. of Approved asphalt at 60 lbs./sq. *0:00: GAFGLAS® Mineral -Surfaced Cap Sheet, Tri -Ply® BUR Grand p Sheets lb or GAFGLAS® EnergyCapT" Mineral -Surfaced Cap Sheet adhefed in a full • mopping of approved asphalt applied within the EVT range an at -rate of?&40. lbs./sq. . • • 3. TOPCOAT' Surface Seal SB or United Coatings— Surface Seal SB Roof C'"AV applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT® MB Plus or United Coatings" Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by TOPCOAT' Membrane or United Coatings'' Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. 4. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 15-1020.01 MIAMI•DAD; COUNTY Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 11 of 67 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® F1exPly' 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 1/4" DensDeck® Roof Board or Y2" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: • • • • 1. Fire classification is not part of this acceptance; refer to a current Approved Roofipg4terials• • • Directory for fire ratings of this product. • 2. Insulation may be installed in multiple layers. The first layer shall be attached irroorpliance with Product Control Approval guidelines. All other layers shall be adhered in a full Qg of • • 0 * approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or rALelianically• • • • attached using the fastening pattern of the top layer * 0:00: • 3. All standard panel sizes are acceptable for mechanical attachment. When applie*i*ip•proved asphalt, panel size shall be 4'x 4' maximum. • 4. An overlay and/or recovery board insulation panel is required on all applications-oveib closedVetl" • foam insulations when the base sheet is fully mopped. If no recovery board is usetl the•base sheet. shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip• mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 IV., as tested in compliance with Testing Application Standard TAS 1.05. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 15-1020.01 MwMi•naDr 0YA11 Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 67 of 67 9/14/2017 Page Bottom See General Information for Roofing Systems TGFU.R1306 - Roofing Systems TGFU.R13®C Roofing Systems Roofing Systems sees 0•e 0009:0 e0 0 • 9000.9 e • . • 0900"" GAF e9see11306 1CAMPUS DR •e•e sees•• 0099 • • PARSIPPANY, N7 07054 USA see* s ' • • e •' 00900• • • RUBEROID@ 20 Smooth" or "RUBEROID@ Mop Smooth" or "RUBEROID@ Mop Smooth 1.5" may be utilized as aneltema s tgfl{pe G2 ..... GAFGLAS@ #75 Base Sheet' or "Tri -Ply® #75 Base Sheet" or "GAFGLAS@ #80 UltimaTM' Base Sheet" base sheets in anyof the following • • • • 0.0.00 • • Classifications. • e • • 1/2 -in. thick (minimum) gypsum board or 1/4 -in. thick (minimum) Georgia-Pacific Gypsum LLC "DensDeck,@ RogQfboard" sp%)ensDeck(6"n"4* Roofboard" or "DensDeck@ DuraGuardTM Roofboard" or 1/4 -in. thick (minimum) United States Gypsum Cor"S6CUR0CK,@fRoof Board" (:fYQ% FRX-G) or"SECUROCK@ Glass -Mat Roof Board" (Type SGMRX) maybe used in any existing noncombustible decktlassifioMne. When this is e done, the resulting roofing system is acceptable for use over combustible (15/32 -in. thick minimum) roof decks. However,tbe butt joints in the gypsum board and Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck@) Prime Roofboard" or "DensDeck@ DuraGuard— Roofboard" are to offset a minimum of 6 -in. with the butt joints in the roof deck. If polystyrene is part of the roof system, it must be placed below the overlayment board. 1/4 -in. thick (minimum) "SECUROCK@ Roof Board" (Type FRX-G) and "SECUROCK@ Glass -Mat Roof Board" Type SGMRX) are limited to a maximum 3:12 slope when used over a combustible deck in a system with any UL Classified insulation except polystyrene. Multiple plies of Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Flex Ply 6" or "Tri -Ply@ Ultra -Flexible Ply 6" may be adhered to Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuard " Roofboard" in hot roofing asphalt. GAFGLAS@ FlexPly" 6 5L" and "GAFGLAS@ F1exPIyTM 6" may be used interchangeably in any roof covering system listed below. EnergyGuardTM' Ultra" is an acceptable alternate to "EnergyGuardTM'" in any applicable Classification. GAFGLAS@ Stratavent@ Nailable Venting Base Sheet" may be mechanically fastened or fully adhered with hot roofing asphalt over noncombustible decks and as a recover over existing roof systems. EnergyGuardu4 Perlite Insulation" may be utilized as a cover board over "EnergyGuardTM'" in any of the following systems. Unless otherwise indicated, the roof insulation is mechanically fastened, fully adhered with hot roofing asphalt or UL Classified urethane insulation adhesive. Polystyrene referenced in any of the following Classifications include insulation. Unless otherwise indicated, all insulations may be adhered with any UL Classified Insulation Adhesive per the manufacturer's installation instructions (excluding "LRF Adhesive O") in any applicable Non -Combustible Roof Deck Classifications. EnergyGuardTM Tapered" is an acceptable alternate to "EnergyGuardTM" in any applicable Classification. EnergyGuardTM" Ultra Tapered" is an acceptable alternate to "EnergyGuardTM" Ultra" in any applicable Classification. EnergyGuardTM" NH Tapered" is an acceptable alternate to "EnergyGuardTM" NH" in any applicable Classification. EnergyGuardTM NH Ultra Tapered" is an acceptable alternate to "EnergyGuardTM' NH Ultra" in any applicable Classification. EnergyGuardTM' Barrier Tapered" is an acceptable alternate to "EnergyGuardTM' Barrier". EnergyGuardTM' NH Barrier Tapered" is an acceptable alternate to "EnergyGuardTM" NH Barrier". Minimum 1 -in. thick "EnergyGuardTM' Barrier" is an acceptable alternate to "EnergyGuardTM' Ultra" in any applicable Classification. Minimum 1 -in. thick "EnergyGuardTM" NH Barrier" is an acceptable alternate to "EnergyGuardTM' NH Ultra" in any applicable Classification. ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet ("GAFGLAS@ #75 Base Sheet" or'Tri-Ply@ #75 Base Sheet" or "GAFGLAS@ #80 UltimaTM' Base Sheet") is a suitable alternate for Type G1. asphalt glass fiber ply sheet ("GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Flex Ply 6" or "Tri -Ply® Ultra -Flexible Ply 6") in the Class A, B or C roof systems indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet "GAFGLAS@ Stratavent@ Nailable Venting Base Sheet" or "GAFGLAS@ Stratavent® Perforated Venting Base Sheet". Perforated base sheets to be loose laid or fully adhered with hot roofing asphalt and nailable base sheets are to be mechanically fastened granule side down. As an option Type G2 asphalt glass mat base sheet ("GAFGLAS@ #75 Base Sheet" or "Tri -Ply® #75 Base Sheet" or "GAFGLAS@ #80 UltimaTM Base Sheet" or "GAFGLAS@ Stratavent@ Nailable Venting Base Sheet") may be substituted for Type G1 asphalt glass fiber ply sheet httpJ/database.ul.mm/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=TGFU.R1306&ccnshorttiUe=Roofing+Systems&objid=1074351... 1/48 4/27/2018 TGFU.R1306 - Roofing Systems SECUROCK@ Roof Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or perlite/polyisocyanu rate composite or wood fiber/polyisocyanurate composite, any thickness, mechanically fastened or adhered with "LRF Adhesive M" or "TPO LRF Adhesive M Low Temp" or OMG Inc. "Olybond Fastening System", applied as a nominal 3/4 -in. bead or "GAF 2 -Part Roofing Adhesive", applied as a nominal 2-1/2 in. bead with a maximum on -center spacing of 12 -in. or any UL Classified insulation adhesive, applied per the manufacturer's installation instructions. Base Sheet: — One ply Type G2 "GAFGLAS@ #75 Base Sheet"or "Tri -Ply® #75 Base Sheet" or "GAFGLAS@ #80 UltimaTM Base Sheet" or "GAFGLAS@ Stratavent@ Nailable Venting Base Sheet", fully adhered with hot roofing asphalt. Ply Sheet (Optional): — Three or more plies Type GI "GAFGLAS@ Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS@ Flex Ply 6" or "Tri -Ply@ Ultra -Flexible Ply 6", fully adhered with hot roofing asphalt. Membrane (Optional): — "RUBEROID@ Mop Granule" or "Intec Flex PRF" or "Tri -Ply@ SBS Granule" or "RUBEROID@ 30 Granule" or RUBEROID@ 30 Granule FR" or "RUBEROID@ Mop Smooth" or "RUBEROID@ Mop Smooth 1.5" or "RUBEROID@ Mop Plus Smooth" or RUBEROID@ Mop Granule FR" fully adhered with hot roofing asphalt or "RUBEROID@ HW Granule FR" or "RUBEROID@ HW Plus Granule" or "RUBEROID@ HW Plus Granule FR" or "RUBEROID@ HW Granule" or "RUBEROID@ HW Smooth", torch applied. Surfacing: — Roofing gravel, applied at a rate of 400-lbs./100-ft.2 embedded into a flood coat of hot roofing asphalt or As. 10 White Aggregate, applied at a rate of 200-lbs./100-ft.2 embedded into "United Coatings" FireShield MB Rosf Coating" applied Aa rate Eft-•; • 1/2 t0 3-gal./100-ft.2. •' • • • • Coating: — 'TOPCOAT@ EnergyCote•" Elastomeric Coating", applied at a rate of 1/2 to 1-gal./1004 = : • • • • • • • • • • • 12. Deck: C-15/ 32a Incline: 2 • • • • • • • • • • • • • • • Barrier Board (Optional): — Minimum 1/4 -in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roo1;:Qe0; pr "DerisDec;@ Primp • • • 6*640 Roofboard" or "DensDeck@ DuraGuardTM Roofboard" or minimum 1/4 -in. thick United States Gypsur0 P.;9ECUR0CK" Roof Boa;" Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX), mechanically fastened with butt joints In the* barrier board • • • •;' products staggered a minimum of 6 -in. from plywood deck joints. s • ; • Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanuratle or petlite/potyisocranurates • • e e • composite or wood fiber/polyisocyanurate composite, any thickness, mechanically fastened or adhered with any UV assified insulation • adhesive. • • • • • • • • • Base Sheet: — One ply Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet" or "GAFGLAS@ #80•131timea" Base Sheet"'s or "GAFGLAS@ Stratavent@ Nailable Venting Base Sheet", fully adhered with hot roofing asphalt. • • • Ply Sheet (Optional): — Two or more plies Type GI "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Flex Ply 6" or 'Tri -Ply@ Ultra -Flexible Ply 6", fully adhered with hot roofing asphalt. Membrane (Optional): — "RUBEROID@ Mop Granule" or "Intec Flex PRF" or "Tri -Ply@ SBS Granule" or "RUBEROID@ 30 Granule" or RUBEROID@ 30 Granule FR" or "RUBEROID@ Mop Smooth" or "RUBEROID@ Mop Smooth 1.5" or "RUBEROID@ Mop Plus Smooth" or RUBEROID@ Mop Granule FR" fully adhered with hot roofing asphalt or "RUBEROID@ HW Granule FR" or "RUBEROID@ HW Plus Granule" or "RUBEROID@ HW Plus Granule FR" or "RUBEROID@ HW Granule" or "RUBEROID@ HW Smooth", torch applied. Surfacing: — Roofing gravel, applied at 400-lbs./100-ft.2 embedded into a flood coat of hot roofing asphalt or No. 10 White Aggregate, applied at a rate of 200-lbs./100-ft.2 embedded into "United Coatings""' FireShield MB Roof Coating" applied at a rate of 2-1/2 to 3- gal./100-ft.2. Coating: — "TOPCOAT@ EnergyCoteTM Elastomeric Coating", applied at a rate of 1/2 to 1-gal./100-ft.2. 13. Deck: NC Incline: 1/2 Membrane: — One or more plies "RUBEROID@ Torch Smooth" or "Tri -Ply@ APP Smooth" torch applied. Surfacing: — Minimum 1/2 -in. thick exterior grade ceramic plaza deck walking tile, adhered in thin -set and grouted per the manufacturer's installation instructions. 1. Deck: C-15/32 Class B - Ballasted Incline: 1/2 Insulation (Optional): — Minimum 2 -in. thick polyisocyanu rate mechanically fastened with the butt joints in the insulation staggered a minimum of 6 -in. from plywood deck joints. Base Sheet: — One ply Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet" or "GAFGLAS@ #80 Ultima TM Base Sheet" or "GAFGLAS@ Stratavent@ Nailable Venting Base Sheet" or "GAFGLAS@ Stratavent@ Perforated Venting Base Sheet" or "GAFGLAS@ Flex Ply 6" or "Tri -Ply@ Ultra -Flexible Ply 6", mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet: — Two or more plies Type GI "GAFGLAS@ Ply 4" or'Tri-Ply@ Ply 4" or "GAFGLAS@ Flex Ply 6" or "Tri -Ply@ Ultra -Flexible Ply 6", fully adhered with hot roofing asphalt. Membrane (Optional): — "RUBEROID@ Mop Granule" or "Intec Flex PRF' or "Tri -Ply@ SBS Granule" or "RUBEROID@ 30 Granule" or RUBEROID@ 30 Granule FR" or "RUBEROID@ Mop Smooth" or "RUBEROID@ Mop Smooth 1.5" or "RUBEROID@ Mop Plus Smooth" or RUBEROID@ Mop Granule FR" fully adhered with hot roofing asphalt or "RUBEROID@ HW Granule" or "RUBEROID@ HW Plus Granule" or "RUBEROID@ HW Granule FR" or "RUBEROID@ HW Plus Granule FR" or "RUBEROID@ HW Smooth% torch applied. Surfacing: — Roofing gravel, applied at a rate of 400-lbs./100-ft.2 embedded into a flood coat of hot roofing asphalt or No. 10 White Aggregate, applied at a rate of 200-Ibs./100-ft.2 embedded into 'TOPCOAT@ Fireshield MB", applied at a rate of 2-1/2 to 3-gal./100- ft.2. Coating: — "United CoatingsTM FireShield MB Roof Coating" applied at a rate of 1/2 to 1-gal./100-ft.2. Gass°A'= Fully Adhered 1. Deleted. 2. Deleted. 3. Deleted. 4. Deleted. 5. Deleted. 6. Deleted. 7. Deleted. httpJ/database.ul.com/cgi-bin/XYV/tempiate/LISEXT/1 FRAME/showpage.html?name=TGFU.R1306&ccnshonttitle=Roofing+Systems&objid=1074351933&cfgid=10 4/27/2018 8. Deleted. 9. Deck: C-15/32 TGFU.R1306 - Roofing Systems Incline: 1/2 Barrier Board (Optional): — One or more layers minimum 1/4 -in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuardT" Roofboard" or minimum 1/4 -in. thick United States Gypsum Co. SECUROCKO Roof Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — One or more layers perlite or glass fiber or 3/4 -in. minimum or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or phenolic, 1-1/2 in. minimum. Base Sheet: — One or more plies Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply® #75 Base Sheet" or "GAFGLASO #80 Ultima'" Base Sheet" or "GAFGLASO Stratavent@ Nailable Venting Base Sheet" or "GAFGLAS@ Stratavent@ Perforated Venting Base Sheet" mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet: — One or more plies Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLASO Flex Ply 6" or "Tri -Ply® Ultra -Flexible Ply 6" fully adhered with hot roofing asphalt. Membrane: — "RUBEROID@ Mop Granule FR" or "RUBEROID@ Mop Plus Granule FR" or "RUBEROID@ EnergyCapTM Mop Plus Granule FR" fully adhered with hot roofing asphalt. 00600" Coating (Optional): — "GAF Fibered Aluminum Coating" applied at a rate of 1-1/2 gat./100-ft.2. ; • • • • • •,.., 10: Deck: C-15/32 Incline: 1/2 Barrier BoardO".q ptional): —One or more layers minimum 1/4 -in. thick Georgia-Pacific Gypsum LLC %Deck@ Roofboard" or DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuardTM Roofboard" or minimum 1/4-1n. thick Unitedates Gypfdth*(-% • • SECUROCKO Roof Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX). 6600 0000 Insulation (Optional): — Perlite or fiber glass or polyisocyanurate or urethane or perlite/polyisocyarffftcemposiie. at • • Base Sheet: —One or more layers Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply@ #75 Base Sheaf! Ultima— Base Sheet" or "GAFGLASO Stratavent@ Nailable Venting Base Sheet" or "GAFGLASO Stratavent@ PgrMW Venting Base Sheet" air';' Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri -Ply@ BUR Granule Cap Sheet" mechanicallyofastened or fully adhered with hdt,, roofing asphalt. 0• • 000000 PI Sheet(Optional): — One or more lies T * * * * %Tri -PIPlypTypeGl "GAFGLASO Ply 4" or 'Tri -Pty@ Ply 4" or "GAF(AS t lex Ply6" or yp 0 Ultra -Flexible Ply 6" fully adhered with hot roofing asphalt. • • • ., • • • • • • Membrane: — "RUBEROIDO Mop Granule FR" or "RUBEROID@ Mop Plus Granule FR" or "RUBEROID@ EnergyCapT1* VqP ius Granule FR" fully adhered with hot roofing asphalt. 11. Deck: C-15/32 Incline: 1/2 Barrier Board (Optional): — One or more layers minimum 1/4 -in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuardTM Roofboard" or minimum 1/4 -in. thick United States Gypsum Co. SECUROCKO Roof Board` (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — Perlite or fiber glass or polyisocyanurate or urethane or perlite/polylsocyanurate composite, butt joints offset a minimum of 6 -in. from plywood deck joints. Base Sheet: — One or more plies Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet" or "GAFGLASO #80 Ultima TM Base Sheet" or "GAFGLASO Stratavent@ Nailable Venting Base Sheet" or "GAFGLASO Stratavent@ Perforated Venting Base Sheet" or Type G3 "GAFGLASO Mineral Surfaced Cap Sheet" or 'Tri -Ply@ BUR Granule Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet (Optional): — One or more plies Type G1 "GAFGLAS@ Ply 4" or'Tri-Ply@ Ply 4" or "GAFGLASO Flex Ply 6" or'Tri-Ply@ Ultra -Flexible Ply 6" fully adhered with hot roofing asphalt. Membrane: — One ply "RUBEROID@ Torch Smooth" or "Tri -Ply@ APP Smooth", torch applied or "RUBEROID@ Mop Smooth" or RUBEROIDO Mop Smooth 1.5" or "RUBEROIDO Mop Plus Smooth" fully adhered with hot roofing asphalt. Membrane: — "RUBEROIDO Mop Granule FR" or "RUBEROIDO Mop Plus Granule FR" or "RUBEROID@ EnergyCapTM Mop Plus Granule FR" fully adhered with hot roofing asphalt. 12. Deck: NC Incline: 1 Barrier Board (Optional): — One or more layers minimum 1/4 -in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuardTM Roofboard" or minimum 1/4 -in. thick United States Gypsum Co. SECUROCK@ Roof Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — Perlite or fiber glass or wood fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite. Base Sheet: — One or more layers Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Pty@ #75 Base Sheet" or "GAFGLAS@ #80 UltimaT" Base Sheet" or "GAFGLASO Stratavent@ Nailable Venting Base Sheet" or "GAFGLAS@ Stratavent@ Perforated Venting Base Sheet" or Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or 'Tri -Ply@ BUR Granule Cap Sheet" mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet (Optional): — One or more plies Type GI "GAFGLASO Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Flex Ply 6" or "Tri-Plye Ultra -Flexible Ply 6" fully adhered with hot roofing asphalt. Membrane: — "RUBEROIDO Mop Granule FR" or "RUBEROID@ Mop Plus Granule FR" or "RUBEROID@ EnergyCapTM Mop Plus Granule FR" mechanically fastened or fully adhered with hot roofing asphalt. 13. Deck: NC Incline: 1/2 Barrier Board (Optional): — One or more layers minimum 1/4 -in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or DensDeckO Prime Roofboard" or "DensDeck@ DuraGuardTM Roofboard" or minimum 1/4 -in. thick United States Gypsum Co. SECUROCK@ Roof Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — Perlite or fiber glass or wood fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite. Base Sheet (Optional): — One or more plies Type G2 "GAFGLASO #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet" or "GAFGLAS@ 80 Ultimal " Base Sheet" or "GAFGLASO Stratavent@ Nailable Venting Base Sheet" or "GAFGLAS@ Stratavent@ Perforated Venting Base Sheet" or Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri -Ply@ BUR Granule Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet (Optional): — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri -Ply® Ply 4" or "GAFGLAS@ Flex Ply 6" or "Tri -Ply@ Ultra -Flexible Ply 6" fully adhered with hot roofing asphalt. Membrane: — One ply "RUBEROIDO Torch Smooth" " or "Tri -Pty@ APP Smooth", torch applied or "RUBEROIDe Mop Smooth" or RUBEROID@ Mop Smooth 1.5" or "RUBEROIDO Mop Plus Smooth" fully adhered with hot roofing asphalt. Membrane: — One ply "RUBEROID@ Mop Granule FR" or "RUBEROID@ Mop Plus Granule FR" or "RUBEROID@ EnergyCapm Mop Plus Granule FR" fully adhered with hot roofing asphalt. http://database.ul.comlogi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=TGFU.RI306&ccnshortbge=Roofing+Systems&objid=1074351933&cfgid=10