Loading...
RF-19-1549Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 ftlTn-n,Iq Issue Date: Location Address Parcel Number 5 NE 102ND ST, Miami Shores, FL 33138 1132060131640 Contacts Permit No.: RF -07-19-1549 Permit Type. Roof Work Classification: rite/flat Permit Status: Approved' Expiration: 01/13/2020 ROBERT SAKZ Owner DEL SOL ROOFING ENTERPRISE INC Contractor 5 NE 102 ST, MIAMI SHORES, FL 331382322 LISSETTE PACHECO Business: 3052295722 Inspection Requests: Description: RE -ROOF TILE & FLAT Valuation: $ 29,900.00 305-762-4949 Total Sq Feet: 3,315.00 Fees Amount Application Fee - Other $50.00 CCF $18.00 DBPR Fee $4.88 DCA Fee $3.25 Education Surcharge $6.00 Roofing Fee $275.00 Scanning Fee $12.00 Technology Fee $8.13 Total: $377.26 Payments Date Paid AmtlPaid Total Fees $377.26 Credit Card 07/16/2019 $327.26 Credit Card 07/08/2019 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorizfothe above named contractor to do the work stated. Authorized Signature: Owner / Applicant Contractor / Agent Date July 16, 2019 Page 2 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (30S) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC CK ROOFING RECEIVED JUL 8 2019 BY: FBC 201 Master Permit No. 1 u�� �� (�`I Sub Permit No. ❑ REVISION ❑ EXTENSION ❑ RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: S M E 102 S f City: Miami Shores County: Miami Dade Zip: 33 13 S Folio/Parcel#: 11 '37-0 (0 o 13 hsKo Is the Building Historically Designated: Yes NO _V Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Po&:C72r &Ar7- Phone#: law—?-- � Y� Address: 5 N E 107, gr City: I anees State: (-I . Zip: 331:5S_ Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: DeC56 L eOcifiL!c Phone#: 305 2-Z6 02113 Address: 1510 NW 14 W City: Qualifier Name: IC -1 Zip: 33124 Phone#: 395-- 27*014 9_ State Certification or Registration #: to Certificate of Competency #: DESIGNER: Architect/Engineer: Address: City: State: Zip: Value of Work for this Permit: $__`Zqfqg% Square/Linear Footage of Work: 331sf Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ElDemolition Description of Work: PC-- f0d r— -Alle- /e Specify color of color thru the: b'ie� PALW CIgnM44 Submittal Fee $ Scanning Fee $ Technology Fee $ Structural Reviews $ Permit Fee $ Radon Fee $ Training/Education Fee $ CCF $ CO/CC $ DBPR $ Notary $ Double Fee $ Bond $ SOO • co TOTAL FEE NOW DUE $ S 2 '� • ?-0O (Revised02/24/2014) G2 —4,1 2-6 Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued in the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signatu ER or AGENT The foregoing instrufnent was acknowledged before me this —� dayf '2019 by 1)(0C'� , who is personally known to me or who has produced F&L' as Signature CONTRACTOR The foregoing instrument was acknowledged before me this day of It 20 by lA. Sti ho is sopa ow to me or who has produced identification and who did take an oath. identification and who did take an oath. as NOTARY PUBLIC: NOTARY PUBLIC: Sign: I Sign: Print: v� Print: JAVIER PUIG Pun PU Seal: NOTARY PUBLIC Seal: tAR NOTARY PUBLIC STATE OF FLORIDA Comm# (360785 STATE c _ STATE OF FLORIDA ? Comm# GG078559 1� APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) t Florida Building Code 6th Edition 2017 ' HIGH VELOCITY HURRICANE ZONE UNIFORM ROOFING PERMIT APPLICATION Section A (General Information) Master Permit No. Process No. Contractor's Name --)d r I Job Address Roof Category ` 1P Low slope _ Mechanically Fastened Tile Mortar/Adhesive Set Tile Asphaltic Shingles Metal Panel/Shingles _ Wood Shingles/Shakes Prescriptive BUR -RAS ISO Are there RECE�V� Gas Vent Stacks? # .1 0 8 019 Yes 0 N09D Type: Natural O LPGX O BY: Roof Type New Roof Re -roofing _ Recovering _ Repair T Maintenance Roof System Information • • • • Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) • •: •„• • • -t -0 00 Section B (Roof Plan) • • • • • • • • • ... 0000 Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scLa'ers and • • . )verflow drains. Include dimensions of sections and levels; clearly identify dimenQi;Af elevate4 3ressure zones and location of parapets. • t. -_ - _ l t t ( ' i { . • • ..l.. • .I LLL T 1 � T _A i 1 j y i _ , E r. r t' aua I �J fl I � E t 0bd ( V IF r < Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section Clow Sloped Roof System) Fill in Specific Roof Assembly Components and Identify Manufacturer (If a component is not used, identify as'NAJ System Manufacturer. NOA No.:1!2 Fastener Spacing for Anchor/Base Sheet Attachment Field: 6 ' oc @ Lap. # Rows _�t_ @120C Perimeter -(e—' oc @ Lap, # Rows —4 @ _k' oc Comer. -' oc @ Lap, # Rows — Design Wind Pressures, From RAS 126 or Calculations: •Q Number of Fasteners Per Insulation Pmax1: -f rr� � 6 Pmax2:- Pmax3:� (�� Board Max Design Pressure Tgpe Specific NOA System: 'S L• 5 Deck: Type: \,Ow A . Gauge/Thickness: Slope: Anchor/Base Sheet & No. of Ply(s): ... Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer., Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Field Perimeter r Comer •__ Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Indicate : Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that C7Comply with RQ S, 111 and Chapter 16. ply 0000 C III, Fr. 00000 C.Q � is �d ��i•• •• • N VI00•• • H IX 0 -V, CA 0 Parboet d'44. 461 • • • Heipht W Vl Q- 0.•.•. b- EVjjSheqLfqstenerjBondling Material: Ply Sheet(s).& No, of Ply(s): Ply Sheet Fastener/Bondin M erial: - Top Pty.gl SS Top Ply Fastener/ Bonding Material: Surfacing: l9 Mean Roof Height 3X 3 (na(u 2fv 0000•• • • 0000•• 0000. • 0000• 0000. 0000.• • 0000.. • • •000•. • 0 Tile Roof System A MIAMIDDADE Miami -Dade County HVHZ Electronic Roof Permit Form Section D Tile Roof System "Oelivering Excellence Every Day" Roof System Manufacturer: IBORAL ROOFING, LLC Notice of Acceptance Number (NOA): E� Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): P 1: 39.1 P 2: 68.1 P 3: 100.7 Maximum Design Wind Pressures, (From the NOA Specific system): 31.3 psf Fill in the specific roof assembly components. If a component is not required, insert not applicable (n/a) in the text box. Roof Slope: "/12" Roof Mean Height: 13 ft. Method of Tile Attachment: --Adhesive, 2 Small Paddy Polyfoam Polypro-0 Alternate Method of Tile Attachment per NOA: Polyfoam Drip Edge Size & Gauge: —3" face 26 ga.— Drip Edge Material Type:I --Galvinized Metal - ........... Deck Type: --5/8" Plywood— Optional Insulation: Optional Nailable Substrate: _090*_ Optional Nailable Substrafe*Att ldhment: + . • •. .090 **1&*-- • 60.04• •i • ••••• • • . . . •• •• •• • Basesheet Type: •!Y•!• • 30 LB ASTM D-226 • ....:. • • • Fastener Type for Basesheet Attachment: • • 1 1/4 Ringshank nails 12 oc field 6 oc laps Tile Underiayment (Cap Sheet ) Type: Boral tile seal Tile Undedayment Attachment Method: self adhered Drip Edge Fastener Type: 11/4 ringshank nails 4 oc Tile Profile: Boral saxony 900 flat tile Hook Strip/Cleat gauge or weight: --n/a- MIAMIDE Miami -Dade County HVHZ Electronic Roof Permit Form so ' •DA� �.. °Deliver"Ing :Excellence Evei-y Day" Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127' For Moment based tile systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. P 1: 39.1 x x .315 = 12.31 - Mg: 7.62 = Mrl: 4.69 5 31.3 NOA Mf P 2: 68.1 x x .315 = 21.45 - Mg: 7.62 = Mr2: 13.83 c 31.3 NOA Mf .... Mg P3:' 00.7 315 = 31.72 -M 7.62 =Mr3: 24.10 5 31.3 NO,AIAf xx ••�� •�••:• .. ... 000:09 . 0 Method 3 "Uplift Based Tile Calculations Per RAS 127"...... • 0000.. 0000 0000 . . 0000 0000 0000. 'or Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are gre4gr togn or egtA tgthe Fr vp4T§,•fer !ach area of the roof, then the tile attachment method is acceptable. • P .. .. .. 0000.. 0000.. 0000.. '1: xxw:W:xCos 0:El=Fr1: • 5 •NOA F'•0 • 000.. 32:x1:�=� xw:�= -W:�=� xCos 0:El=Fr2:�<_' •• •NOAF' 33:x1:�=�xw:�= -W:�=� xCos 0:El=Fr3:�<_�NOA F' Description Design Pressure Where to Obtain Information to complete tile calculations Symbol P1 or P2 or P3 Mean Roof Height H Roof Slope 1 9 Aerodynamic Multiplier Restoring Moment due to Gravity 'I ~ Mg 00.0_0.:._r..n.�,e_.,....� ..............�...T.....m..,�,. �.....J,.. r�.,..,.,...... Attachment Resistance ..Mf Required Moment Resistance Mr Minimum Attachment Resistance Required Uplift Resistance Average Tile Weight Tile Dimensions F' Fr Where to Find Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional engineer based on ASCE 7. Job Site Job Site Product Approval (NOA) W { Product Approval (NOA) = length w =width Product Approval (NOA) .-a 0:0:00 ... s.. 3+:.. . :.._._.. . :'0000_. .. •sn.. ....e.: ,:v x;. ;.-_. .. ... To Miami shores Vh"ilfage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. Miami Shores Village Building Department Date: (7-4 )191 lej 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: Property Addres Roofing Permit Number: 9999 . . 9999 9999.. Dear Building Official: *0 • 9 • •• • 990.90 .. 9000•6 1A J S certify that I am not required to retrofit the rogf tQ,wall conpiplions of -."my- - building because: • • • • • 90999. 9. 0 9999. )&e just valuation for the structure for purpose of ad valorem taxation is less than $300,0M,00. PleasEr5ttAch probf bf a8 valorem taxation. 9999.. 9999.. ❑ The building was constructed in compliance with the provisions of the Florida Building Cod's (FBC) or 4h the provisions 9999 of 1994 edif f e South Florida Building Code (1994 SFBC) TFO 0� X51��t/G� SignatW— — ' Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this day of JAVIER PUIG NOTARY PUBLIC Notary Public, Sate of Florida at Lar ix -+STATE OF FLORIDA CCFooYmrrv# GG078559 • When the just valuation of the structure for purpose of ad valore ation is equal to or more an9$300,000'Ubea d4f!he��uilding was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigatior. Revised on 5/21/2009 F�ORTW' SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 2.Xnailed enailing wood decks: When replacing roofing, the existing wood roof deck may have to b ccordance with the current provisions of Section R4403. (The roof deck is usually c ncealed prior to removing the existing roof system). 4. -Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking ed from below. The owner may wish to maintain the architectural appearance; therefore, penetration of the underside of the decking may not be acceptable. This provides tA.e option of . • • • maintaining the appearance. .. . •.• • 6:9000 660verflow scuppers (wall outlets): It is required that rainwater lee 0S Off so thafthbOripof is • • ed from a buildup of water. Perimeter/edge wall or other roof extension may block iRis • •: •'. discharge if overflow scuppers (wall outlets) are not provided. It may be nece .; *o *tinstall • •glow • • scuppers in accordance with the requirements of Sections R4402, R4403 and x„13. �Y• • •, . . . . ...... Owner/ ature Date Contra Q r Signature • 005te S NE 162 Sr Property Address Permit Number Revised on 7!9/2009 LD;0710112015; MIAMI•DADE . <.�` MIAMI-DADE COUNTY L�l1�W PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315=2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - rrodyct Control 6 fiction to �. • • used in Miami -Dade County and other areas where allowed by the Authority Having Jurish ttott (AHI).. . ...... .. ...... This NOA shall not be valid after the expiration date stated below. The Miami -Dade County-Pmduct Control Section • (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve M! fight toJMVthis . • product or material tested for quality assurance purposes. If this product or material fails toFer%rm in the accepted • .... . ..... manner, the manufacturer will incur the expense of such testing and the AHJ may immedi;Wy, revoke *tY{Afy, or • suspend the use of such product or material within their jurisdiction. RER reserves the right -to -revoke this, acceptance,' if it is determined by Miami -Dade County Product Control Section that this product or material fails tq lqoe$ $ he ...... requirements of the applicable building code. 0 0 0:....0 This product is approved as described herein, and has been designed to comply with the Florid&ildi'nqCode 00 including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Saxony 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 18-0509.17 and consists of pages 1 through 9. The submitted documentation was reviewed by Freddy Sentino 0 ' NOA No.: 19-0408.01 MIAMI -DAD; Co; NTY Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete Deck Type: Wood SCOPE This NOA approves a system using Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL and described this'Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation. section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions Saxony 900 -Slate Saxony 900 Split Shake Saxony 900 -Shake Trim Pieces Length = 17" Width = 13" thickness = 1-5/32" Length = 17" Width = 13" thickness = 1-9/32" Length = 17" Width = 13" thickness = 1-9/32" Length: varies Width: varies varying thickness 2.1 MANUFACTURING LOCATION 2.1.1 Lake Wales, FL NOA No.: 19-0408.01 MIAMI•DAD, COUNTY 1411 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 2 of 9 . . .... ...... Test ...... .. ...... Specifications Descrwtlon .�.. ...... TAS 112 Flat profile, interlocking, lhi*h'ressure Htruded deck] concrete roof tile with two n..Cles .;or.direct batten, mortar set or adhesive sgt applica4ons. , • TAS 112 Flat profile, interlocking,'high-pressula exlwded concrete roof tile with tw;.0ai :f►oles.: Fol direct 4wk-,- batten, mortar set or adhesive set apphr,449fls. Top surface produced with 4 different configurations: 1. Complete tile brushed 2. Right half brushed (shown in drawing) 3. Left half brushed 4. No brush TAS 112 Flat profile, interlocking, high-pressure extruded concrete roof tile with two nail holes. For direct deck, batten, mortar set or adhesive set applications. TAS -112 Accessory trim, boosted Barcelona, concrete roof pieces for use at hips, ridges and rakes. NOA No.: 19-0408.01 MIAMI•DAD, COUNTY 1411 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 2 of 9 2.2 EVIDENCE SUBMITTED: Test Agency Test Identifier The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies Atlanta Testing & Engineering, Inc. Celotex Corporation Testing Service Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. American Test Lab of South Florida PRI Construction Material 94-084 94-060A 25-7183-6 25-7183-5 25-7214-1 25-7214-5 Project No. 307025 Test #MDC -77 7161-03 Appendix II & III Letter Dated Aug. 1, 1994 P0631-01 P0402 R 1.894/R2.894/R3.894 Test Name/Report Static Uplift Testing TAS 101 (Mortar Set) Static Uplift Testing TAS 101 (Adhesive Set) Static Uplift Testing TAS 102 (2 Quik -Drive Screws, Direct Deck) Static Uplift Testing TAS 102 (2 Quik -Drive Screws, Battens) Static Uplift Testing TAS 102 (1 Quik -Drive Screw, Direct Deck) Static Uplift Testing TAS 102 (1 Quik -Drive Screw, Battens) • • Wind Driven Rain " TAS 100 Wind Tunnel Testing ." TAS 108 (Nail -On) ...... Wind Tunnel Testing TAS 108 (Nail -On) • • • • • • Wind Tunnel Testing • • TAS 108 (Mortar Set) Withdrawal Resistance Testing of • screw vs. smooth shank nails Physical Properties TAS 112 520109-1 Static Uplift Testing 5201114 TAS 101 520191-1 Static Uplift Testing TAS 101 Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Calculations Evaluation Calculations RT0617.04-16 COPO-002-02-12 COPO-002-02-06 COPO-002-02-05 25-7094 25-7496 25-7584/25-7804b-8/25-78044 & 5 25-7848-6 25-7183 Aerodynamic Multipliers Two Patty Adhesive Set System Restoring Moments Due to Gravity TAS 112 TAS 101 TAS 101 TAS 101 Date May 1994 March, 1994 Feb. 1995 Feb. 1995 March, 1995 March, 1995 .... ...... *Oct: 1994 c. 19910 1994o:::: . . :. jujy.1994• • • • • • .Jeer. 1993• Aug. 1994 Dec. 1998 March 1999 February 1996 April 1996 December 1996 March 1995 09/01/16 April 1999 09/01/16 06/29/16 10/12/2016 10/12/2016 10/12/2016 NOA No.: 19-0408.01 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 3 of 9 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. goose, .. . .Y. 4. INSTALLATION • • • : • • • .....Y 4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its componei t§%fiall be jf1Ah?l�d in Strict • compliance with Roofing Application Standard RAS 118, RAS 119, and RAS M.' "" 4.2 Data For Attachment Calculations• .. Y. .. . .....Y Table 1: Average Weight (W) and Dimensions (I x w) sees: Tile Profile Weight -W (lbf) Length -I (ft) '.. VQtb.w (ft): Batten Application Direct Deck Application Saxony 900 0.291 Saxony 900 10.9 1.417 1. 8 Slate, Shake & Split Shake Direct Deck Battens Direct Deck Table 2: Aerodynamic Multipliers - X (ft3) Tile ;L (ft3) X (ft3) Profile Batten Application Direct Deck Application Saxony 900 0.291 0.315 Slate, Shake & Split Shake Battens Direct Deck Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Saxony 900 Slate, Shake & Split Shake Direct Deck Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7.70 7.62 6.61 7.50 6.48 7.34 6.31 7.16 6.13 6.95 NOA No.: 19-0408.01 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 4 of 9 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Fastened Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile •••• Resislance (min 15/32" (min. 19/32" 31.3 z s 3 5 Large paddy DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per plywood) plywood) 2 The Dow Chemical Company TileBondn' one -component foam minimum weight per paddy 13.9 grams. Saxony 900 2-10d Ring Shank Nails 30.9 38.1 17.2 Slate, Shake & Split 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 Shake 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 .#8 Screw 30.8 30.8 18.2 2 .#8 Screws 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail (Field 24.3 24.3 24.2 Clip) 1-10d Smooth or Screw Shank Nail (Eave 19.0 19.0 22.1 Cli •• • • 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 .003;:5 • • • 34.9"0:: 2-10d Smooth or Screw Shank Nails (Eave 31.9 ...39� 32.Z Clip) 0000 fffff ffff fffi ffffY Table 5: Attachment Resistance Expressed as a Moment Mvf(t•lbf) '.f'.' toff. for Two Paddy Adhesive Set Systems :so:*: • f Tile Application Tile Tile Application . Minimur�=tt9Chmept Profile 93 5 •••• Resislance Saxony 900 Slate, Shake & Split Shake Adhesive' 31.3 z s 3 5 Large paddy DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per 594 1 See foam adhesive manufacturer's component approval for installation requirements. 2 The Dow Chemical Company TileBondn' one -component foam minimum weight per paddy 13.9 grams. 3. ICP Adhesives Polyset® AH -160 two -component foam, minimum weight per paddy 8 grams. 4. DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Saxony 900 Slate, Shake & Split Shake ICP Adhesives Polyset® AH -160 Two -component foam DAP Products Touch N' Seal Storm Bond 2 two -component foam 118.93 40.4 4 93 5 45 6 3 Large paddy placement of 45 grams of Polyset® AH -160. 4 Medium paddy placement of 24 grams of Polyset® AH -160. 5 Large paddy DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 45 grams. 6 Medium paddy DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 24 grams. NOA No.: 19-0408.01 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 5 of 9 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft.-lbf) for Mortar Set Systems Tile Profile Tile Application Minimum Attachment Resistance Saxony 900 Slate, Shake & Split Shake Mortar Set' 43.96 7 Tile-Tite Roof Tile Mortar 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". ORrt�f yy • • • •••••• •• • ••••• • • • • • • • • • • • • • LABEL FOR BORAL SAXONY 900 TILES LAKE WALES•Fh PLANT• • • • • • LOCATED UNDERNEATH TILE • • •. • • 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MIAMI•DADE COUNTY NOA No.: 19-0408.01 �Fj• • • Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 6 of 9 NAIL HOLES V PROFILE DRAWINGS UNDERLOCK I SAXONY 900 - SLATE 5/82" (Slate) s s COVERLOCK. • • MIAMI•DADE COUNTY NOA No.: 19-0408.01 • Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 7 of 9 NAIL HOLES PROFILE DRAWINGS 1-9/32" (Shake) Note: Available Top Surface Finishes 5. Complete tile brushed 6. Right half brushed (shown in drawing) 7. Left half brushed 8. No brush SAXONY 900 - SPLIT SHAKE NOA No.: 19-0408.01 Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 8 of 9 NAIL HOLES V PROFILE DRAWINGS 1-9/32" (Shake) 7 SAXONY 900- SHAKE END OF THIS ACCEPTANCE MIAMI•DADECOUNTY NOA No.: 19-0408.01 . • • • • I Expiration Date: 04/26/22 Approval Date: 05/16/19 Page 9 of 9 MIAMI -DARED • DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA Boral Roofing LLC. 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economv This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to mq%t J1e requirements of the applicable building code. • .... ...... This product is approved as described herein, and has been designed to comply with the Florida Building G da .' including the High Velocity Hurricane Zone of the Florida Building Code. "•: • • • •..:. DESCRIPTION: BORAL TileSeal . "". • .... .... ..... LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,eitgostate a Modowing..... statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein • • • • • RENEWAL of this NOA shall be considered after a renewal application has been filed and jberPhas bpenao chanio...: in the applicable building code negatively affecting the performance of this product. • • • • TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This new NOA consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS PRODUCTS DESCRIPTION: MANUFACTURIGN LOCATION: 1. Brentwood, NH. 2. Houston, TX. EVIDENCE SUBMITTED: Test Agency PRI Construction Materials Technologies, LLC. Trinity ERD Test Identifier OCF-356-02-04 OCF-356-02-02 OCF-356-02-01 OCF-424-02-04 OCF424-02-01 OCF424-02-03 BRLRF-SC 16810.11.17 .:::Soo ...00 ...... Test Name/Repor� • • • 0000 ASTM D 1623. • • • , • TAS 103 ..'..' ASTM D 197(Q • • ASTM D 1623 ' ASTM D 1974 • • • TAS 103 ASTM D 1876 0000 0000 0000.. .. 0000.. 0000 Date : ""' • •67/25/1$•: .. 00 ' D11/24/1.8.:::. • 07/26/18 .' :... A�/25/* •.:. 07/25/ W/25/f8 11/28/17 NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 2 of 4 Test Product Product Dimensions Specification Description BORAL TileSeal 36" x 36' rolls TAS 103 SBS self -adhering asphalt sheet material with a 36" x 72' rolls ASTM D1970 white glass re -enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. Boral Citadel Plus 36" x 72' rolls ASTM D1970 SBS self -adhering asphalt sheet material with a poly film -facer; for use as a mid -ply underlayment in sloped roof assemblies. MANUFACTURIGN LOCATION: 1. Brentwood, NH. 2. Houston, TX. EVIDENCE SUBMITTED: Test Agency PRI Construction Materials Technologies, LLC. Trinity ERD Test Identifier OCF-356-02-04 OCF-356-02-02 OCF-356-02-01 OCF-424-02-04 OCF424-02-01 OCF424-02-03 BRLRF-SC 16810.11.17 .:::Soo ...00 ...... Test Name/Repor� • • • 0000 ASTM D 1623. • • • , • TAS 103 ..'..' ASTM D 197(Q • • ASTM D 1623 ' ASTM D 1974 • • • TAS 103 ASTM D 1876 0000 0000 0000.. .. 0000.. 0000 Date : ""' • •67/25/1$•: .. 00 ' D11/24/1.8.:::. • 07/26/18 .' :... A�/25/* •.:. 07/25/ W/25/f8 11/28/17 NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated Deck Description: 15/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. Base Sheet: One or more plies of ASTM D226 Type H or ASTM D2626 with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Ply Sheet Apply one layer of Boral Citadel Plus over Base sheet as per current approval. (Optional): Membrane: One or more plies of BORAL TileSeal Underlayment with a minimum 3" head lap and minimum 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps without black selvage area shall be sealed under lap using an SBS modified mastic. Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be b"nailed to deck with approved annular ring shank nails and tin caps at a maxitrun3 4;" o.c' to tire` side • .. • .. .. . . laps. No nails or tin caps shall be exposed. ••. •• 000000 Surfacing: Approved for Adhered Roof Tile using TILE BOND or AH -160, M 4wically FKjj ned .. Roof•..: Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingleasc8mbliet..• • • • . NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 3 of 4 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. .4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Tiles shall be stored on battens on roof pitches greater than 6:12". 9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Acceptance listing BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate docu + • . 4 6 mentat h1g. provided to detail compatibility of the products, wind uplift resistance, and fire testing r;ji4ks - • • 10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loo"do0king panel9. Sweep.. the deck thoroughly to remove any dust and debris prior to application. • 00:00 6 6 . 06.49. 11. When applying the membrane in the valley, start at the low point and work to the high pt j.*mlling4t ; *M* embrane. from the center outward in both directions. For ridge applications, center the membrana aiW wll frory ihz cente ; �.. • outward In both directions. *00000 ••. • • • • . • 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface3 giviri� special Attention to •, • 0 overlap areas. 0000.. . 0.0 4 0 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly eurrent Product- Control:"••; Notice of Acceptance and applicable Building Code. • • 4 • 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment shall be applied over the underlayment, and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below END OF THIS ACCEPTANCE NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 4 of 4 c �jr r IMI DE MIAMI-DADE COUNTY M. PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy ICP Adhesives and Sealants, Inc. 12505 NW 44' Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida.BAfltling Code including the High Velocity Hurricane Zone of the Florida Building Code. "" • • • • • • .. . 909 . DESCRIPTION: ICP Adhesives Polyset' AH -160. 0000 . 9000 0900 ....� LABELING: Each unit shall bear a permanent label with the manufacturer's name or log 4ity, state. and folloviVK• statement: "Miami -Dade County Product Control Approved", unless otherwise noted hereiff • • • • 9' 000090 0 RENEWAL of this NOA shall be considered after a renewal application has been filed and there has:aeeAjio change:* in the applicable building code negatively affecting the performance of this product. • • 0 • • • 0 bass; 9 . • .999 TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives' Polyset' AH -160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset® AH -160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications ICP Adhesives N/A TAS 101 Two component polyurethane foam adhesive Polyset®AH-160 ICP Adhesives Foam N/A Dispensing Equipment 0000 Dispenser RTF1000 *00000 0 0.0 0. ICP Adhesives ProPack® N/A Dispensing Equipment 0 0. 0 000006 •• 0000.. 30 & 100 ""' • • 0 .000. 0000 0000 . 0 0000 0000 0000. PRODUCTS MANUFACTURED BY OTHERS: *9:**: .. .. .. . 0000.. Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current t40&Ivhich list -attachment .' resistance values with the use of ICP Adhesives Polyset® AH -160 roof tile adhesive. ; • • • • • ; 0 0 0 6 . 0000 000 . .. . MANUFACTURING LOCATION: • •• ' 0000 1. Tomball, TX. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 1.6 lbs./ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change @ -40'F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier Test Name/Report Date #94-060 TAS 101 04/08/94 257818 -IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 NB -589-631 ASTM D 1623 02/01/94 9637-92 ASTM E 108 04/30/93 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 01/16/95 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 "19/12 P39740.02.12 TAS 101 • • • b0Y2012 • • 9 6: - 6TAS TAS 123 "• ' • 0000.. 6 0 *00000 0 0 0 0 0 528454-2-1 TAS 101 096..6 1u: /98 • • • •; 528454-9-10000 • • 0 6 6 000 0 ; 00 0000. 528454-10-1 0000.. 6. 6 00:00' 520109-1 TAS 101 •••••6 •i•2- 798 •••••• 520109-2 " • • •' • 520109-3 0000.. ""•' 520109-6 0000.. 520109-7 • 0000 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset' AH -160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset' AH -160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. MIAMI•DADE COUNTY ...• ynlj NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset' AH -160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset, AH -160. 2. ICP Adhesives Polyset' AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH -160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset' AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. ICP Adhesives Polyset® AH -160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP 0000 Adhesives ProPack' 30 & 100 dispensing equipment only. • • • • • • • • • • 7. ICP Adhesives Polyset® AH -160 shall not be exposed permanently to sunlight. •' • • • • .0000. .. 0000.. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives . • 0000.. Polyset AH -160 has been dispensed. • • • • 0•.. 9. ICP Adhesives Polyset' AH -160 placement and minimum a weight shall be in ac • • ce wit • • •e : • • Y P patty � FPi��� 11 �. 0000. 'Placement Details' herein. Each generic tile profile requires the specific placement nWd J*rein.0..' . • • 0.0.0 0000.. 0000.. .. . . . .. . NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram • • • • • • • • LABELING: • Area Weight Eave Course - Flat, Low, High All approved listed herein be labeled • products shall and shall bear the imprint or identifiable*jV*�*;king of �� • Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 gr;tttsuijder pan BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 • • • • • • • • LABELING: • • • • • • • All approved listed herein be labeled • products shall and shall bear the imprint or identifiable*jV*�*;king of �� • • • manufacturer's name or logo and following statement: "Miami -Dade County Product Control A1113roved"Ar t0 a Mia• •"; • Dade County Product Control Seal as shown below. • • • • • • • .. .. • • • • • • • • • tom_ AMI cou(�t rr ; • : • . . BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # I Mau thfough plastic c msnt Paddy Sfmoaih Td.) 1when t•quir•d:, "JndPdLgrnrnt 2 if Baat•rrS apttorlal 2. Eev Cluaurr ._— Nail through phsstk cement (when repaired) a _ Paddy ISenedth Talrl tRrldv.eldynxmE '� �-'`'..,e ' ''•. � i z i X, `* 'tea ,. 19in:r'' Battens opaional Wit•=�.� - -J � f•Fv Lave Clusure Eric Course - — Fascia 1Nal thmugih pld%1ic c.n, •nt--.. *hen requitotl' Padd-F 1RPnrdth:Tilrl Vnd•rl,ynernt titin.: 2 in.wida ..` . Battens 1' o{suxrnal - r Ei.+r Course • __:;�.w: � �:: .R�-,• ' Fiscia loin, lin. �' ~ Eavr dosu►e a: * F•f" Doipedge Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 ram) x 1" (25'.4 mit) foarq„• paddy onto the underlaypnentpositionad as shown under the pan portion oftht the closest to the • • • . . overlock of the tile bei$4 %8f.' • 2. Continue in same manger, jij$ure apljr * mately f 909 . (109.7 cm2) — 23 (148.40ti.)'square jyjebladhes�ve . • • contact with the underside of -the tile. . High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL ## 2 AR through FUNlic rpmrnO PAddy iBNnralh T&I ,;nh ltn required) ► in ea¢taris OotionaI F)"Coueia. _ Nail through plastic cernenA 'when requiredl Paddy16ane4d%tile? UmderlAynrne- ���`. �•,.-- `0.00 �j._.-_- 2,n �• t Battens oivnal ha 10tH;,•`_ <.,,;.._2 ~2�.� o . •?'ham --. �: Ewa CLowm - .-0::000 ;•�_•: ,�.�.,. Flat/Low Profile Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2) - 12 (77.4 cm2) square inch adhesive contact with the underside of the tile. • • • • . . 0000 0000.. 0000.. Medium Profile/ Double PA&TK • •00•0000 :0000: 0 1. Starting at the eave coursepappry a mii ra i 2" (548•,. mm) x 10" (254 mm) x I I (J5 at mm) jeam paddy • •: • onto the underlayment poSttidtied as shbt T? under the % • 000 pan portion of the tile clog* UNI.. the overlock of the 0. tile being set. Insure apprpxirrVtely 1 E100#7 cm2 ="" 23 (148.4 cm2) square ind%#dhesive cpntajt with 1" • • underside of the tile. **:**a 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Nail ihrough ptauk ceolertt _ , M'fiCle required) _ PAddy i3.rs-Oh Til., In. Hallen, "tianai (. ' i [aye CouTSt---.,.T.-�.!�+.-,�,--^+':'-frK171 >- 's:w..Phai* r 14 an,'--.-_ 2 N1.-�'r>+t -,:'`� - - Emx ci3•osun� High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure appr9ximajely 17" (109.7 cm2) - 19 (122.6 cibl) s4uare inchWhesive " • contact with the underside off' the tile. 0000.. .. 0000.. 0000.. 0000.. 0000 0000 . . 0000 0000 0000. .. .. .. . 0000.. 0000.. . . . . 0000.0 0000.. . . 000000 00 0 0 00 0 0 . . NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 Nail th rough plastic cement Paddy rbetweentilesl [when required; % y Battens optional '~ Paddy lundertile) Single paddy ! on top of file ��' Singlepadd andertil� Single paddy ' on undedayment 2 x 4 in. �2 in. i f f Fascia ----Eaveclosure Flat/Low Proflle Tile Nail through plastic cement Single paddy under the I.when required) / r"•., Paddy (between tiled r i - Battens � �� f Paddylundertflel optional V Singlepaddy` on top oftile �''. x 4 in. ` glepaddyon ` 2x4in. X sind '•> un ertayment�f—� \ ..IOm ' tin f/ Eave Closure Eave Course y— Fascia Medium Profile Tile 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the Overlock of the tile being set. Leave approximately 4" (10 1.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 int (109.7-148.4 cm2) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tije„gr under the pan portion of the tile, closest to thS i>edeflock fqr.... the second course tile to -be installedr -Insare • • approximately 8-9 int C.I?.62-58.1 cm2) of adhesio • • contact with the underside of the tile. ' :....: •••••• •• • ••••• (Instructions continued onobAtfvage) • • • • • • • • •.. • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nail through plastic cegiem." Single paddy under tile (when required) / X Paddy Ibetween tiles) Battens X optional '�'`. Paddy (under tile:: ,sin le pddy`�. ounderlaym n Single 23c4in/\`', Paddy on top o file— Ea ile Eave Course s tel' -Fascia 'Wee hole 0 n., 2 in,, ' f``` f Eave closure •1,F /` Drip edge High ProfileTlle 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x %" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9 (58.1 cm2) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough adhesive to achieve 65 to 70 sq. in. Steep pitch applications In contact with the pan tile. (when required) 2) Turn covers upside down. Place adhesive in to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25 sq. in. contact area. o IUnderlayment-'-�,- "i o _ o Sheathing Eave closure (motar shown) Weephole Fascia Board Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm2) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing Munderside of the tile. Apply a minimum 1" (U.44m) x jD;'. • (254 mm) bead of adheaive:directlyon the inner .' edge of each side of dwCdver tile. Lealae 0000:0 approximately 3/4" (19•rhM) to 1" (25.4 mm);....; from the outside edge orthe tile, �nwaid, free of ..... .... ..... foam to allow for exp>lpp. • • • 4. Turn cover tile over aitep team is applied and place onto pan tile course. Insured Vipjmum-of• • • • 20 (129 cm2) - 25 (161.3.dm2) sgdare inch ;.... contact area on each side otthe cover dile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 MIAM1,�D DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or mattrial fails to 6006the .... . requirements of the applicable building code. • • • . • • This product is approved as described herein, and has been designed to comply with the FlonMeguilding Codb including the High Velocity Hurricane Zone of the Florida Building Code. • • • • • • .... .... . . .... .... ..... DESCRIPTION: Polyglass Self -Adhered Roof System over Wood Decks • • • • • • • • • • • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or log(, city,,state and f9llowing. statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. - .. • . • • • • RENEWAL of this NOA shall be considered after a renewal application has been fled and there has bees no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 17-1016.01 and consists of pages 1 through 38. The submitted documentation was reviewed by Alex Tigera. V � M NOA No.: 19-0311.04 Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 1 of 38 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Modified Bitumen Materials SBS/APP/TPO Deck Type: Wood Maximum Design Pressure -112.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Polyanchor Polyglass G2 Base Elastoshield HT XtraFlex SBS HT Base 650 Elastobase Elastoflex SA V Elastoflex SA V FR Test Dimensions Specification Product Description 250' x 48" ASTM D 4601, A polymer woven, high performance, synthetic base Type II sheet. 108'x 36" ASTM D 4601, Asphalt -coated fiberglass reinforced base sheet Type II 65' 8" x 3' 3-3/8" ASTM D 6162 SBS modified asphalt coated fiberglass/p&pster reinforced base sheet. 4444 4444.. 65' 8" x 3' 3-3/8" ASTM D 6162 65' 2" x 3' 3-3/8" 66' 8" x 3' 33/8,1 66' 8" x 3' 3-3/8" ASTM D 6163, Type I ASTM D 6163, Type I ASTM D 6163, Type I 6 0 • SBS modified asphalt coated-fiberglass7pUyaster 46%9 60 4444.. reinforced base sheet. • 4444.. 4444.. SBS modified asphalt coat0l*ffbgrglassMrif4rced • • base sheet. 4444 4444 4444. Self -adhered, fiberglass reinforced, SB&.1mmed bitumen membrane with aMtt adhering b;fck face and • a smooth top surface. �' 444:4 **see* Self -adhered, fire -rated, derglass reilroodJ SBS: modified bitumen membrane with a selikadhering back face and a smooth top surface. Elastoflex SA V 66' 8" x 3' 33/8" ASTM D 6163, Self -adhered, fiberglass reinforced, SBS modified PLUS Type I bitumen membrane with a self -adhering back face and a smooth top surface. Elastoflex SA V 66' 8" x 3' 3-3/8" ASTM D 6163, Self -adhered, fire -rated, fiberglass reinforced, SBS PLUS FR Type I modified bitumen membrane with a self -adhering back face and a smooth top surface. XtraFlex SBS Base 66' 8" x 3' 33/8" ASTM D 6163, Self -adhered, fiberglass reinforced, SBS modified SA Type I bitumen membrane with a self -adhering back face and a smooth top surface. XtraFlex SBS Glass 65' 8" x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced Base Type I base sheet. Elastobase P 65' 8" x 3' 3-3/8" ASTM D 6164, SBS modified asphalt coated polyester reinforced base Type I sheet. Elastoflex SA P 32' 10" x 3' 3-3/8" ASTM D 6164, Self -adhered, fiberglass reinforced, SBS modified Type I bitumen membrane with a self -adhering back face and a granule top surface. NOA No.: 19-0311.04 MIAMI•DAD, COUNTY Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 2 of 38 Elastoflex SA P FR 32'10"x3'3-3/8" ASTM D 6164, Type I Polyfresko G SBS SA 32' 10" x 3' 33/8" ASTM D 6164, Type I Polyfresko G SBS SA 32' 10" x 3' 33/8" ASTM D 6164, FR Polyreflect XtraFlex SBS G SA Polybond Polyflex XtraFlex APP S PolyKool XtraFlex Kool APP S SA Polyflex SA P Polyflex SA P FR Type I Self -adhered, fire -rated, polyester reinforced, SBS modified bitumen membrane with a self -adhering back face and a granule top surface. Self -adhered, fiberglass reinforced, SBS modified bitumen membrane with a self -adhering back face and a granule top surface. Self -adhered, fire -rated, fiberglass reinforced, SBS modified bitumen membrane with a self -adhering back face and a granule top surface. 32' 10" x 3' 33/8" ASTM D 6164, Self -adhered, polymer, SBS modified bitumen Type I membrane with a self -adhering back face and a smooth top surface. 32' 10" x 3' 3-3/8" ASTM D 6164, Self -adhered, fire -rated, polyester reinforced, SBS Type I modified bitumen membrane with a self -adhering back face and a granule top surface. 32' 10" x 3' 3-3/8" ASTM D 6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. 32' 10" x 3' 3-3/8" ASTM D 6222 Torch applied, polyester reisrl'oroed, APP•modified .' bitumen membrane with a*Mj:'8ff polyethylene bank • • face and a smooth or sandeca0t0 * surfac e.0 * � .... 32' 10" x 3' 3-3/8" ASTM D 6222 Torch applied, polyester reivfiorced, Ab&w dified..... bitumen membrane with a'54M pff poj}"byjene bm; • • . .. .. ...... face and a smooth or san; a �o��surface.. 32' 10" x 3' 33/8" ASTM D 6222, Self -adhered, polyester reinforced, APP modified....:. Type I bitumen membrane with � self-gdherithg back face;j;d a white film laminate on the top surface.'*. ' .... 32' 10" x 3' 33/8" ASTM D 6222, Self -adhered, polyester reinforced, APP modified Type I bitumen membrane with a self -adhering back face and a white film laminate on the top surface. 32' 10" x 3' 33/8" ASTM D 6222, Self -adhered, polyester reinforced, APP modified Type I bitumen membrane with a self -adhering back face and a granule top surface. 32' 10" x 3' V/8" ASTM D 6222, Self -adhered, fire -rated, polyester reinforced, APP Type I modified bitumen membrane with a self -adhering back face and a granule top surface. Polyfresko G APP SA 32' 10" x 3' V/8" ASTM D 6222, Self -adhered, polyester reinforced, APP modified Type I bitumen membrane with a self -adhering back face and a granule top surface. Polyfresko G APP SA 32' 10" x 3' 33/8" ASTM D 6222, Self -adhered, fire -rated, polyester reinforced, APP FR Type I modified bitumen membrane with a self -adhering back face and a granule top surface XtraFlex APP G SA 32' 10" x 3' 33/8" ASTM D 6222, Self -adhered, fire -rated, polyester reinforced, APP Type I modified bitumen membrane with a self -adhering back face and a granule top surface. NOA No.: 19-0311.04 Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 3 of 38 Polyglass APP Base PG 100 65' 8" x 3' 3-'/8" 1, 3, 5, 50, 55 gal, tube or 17 oz. spray can ASTM D 6509, APP modified asphalt coated fiberglass reinforced Type I base sheet. ASTM D41 A penetrating solution of solvent and a blend of selected asphalts used to promote adhesion. PG 350 1, 3, 5, 50, 55 gal. or ASTM D3019 ASTM D41 tube Type III PG 400 1, 3, 5, 50, 55 gal. or ASTM D4586 ASTM D3019 tube ASTM D3409 PG 425 1, 3, 5, 50, 55 gal. or ASTM D4586 tube ASTM D3409 PG 450 1, 3, 5, 50, 55 gal. or ASTM D4586 tube PG 500 POLYPLUS 35 POLYPLUS 45 POLYPLUS 50 XtraFlex 10 XtraFlex 35 XtraFlex 50 Premium Modified Wet/Dry Cement WB -3000 A fibered rubberized adhesive designed for use with modified bitumen membranes. A thick, fibered, rubberized flashing cement for use in dry or damp conditions. A thick, fibered, rubberized flashing cement for use in dry or damp conditions. A thick, fibered, rubberized flashing cement. 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement for use tube with modified bitumen membranes. 1, 3, 5, 50, 55 gal. or ASTM D3019 tube Type III 1, 3, 5, 50, 55 gal. or ASTM D4586 tube 1, 3, 5, 50, 55 gal. or ASTM D4586 tube 1, 3, 5, 50, 55 gal, ASTM D41 tube or 17 oz. spray can 1, 3, 5, 50, 55 gal. or ASTM D3019 tube Type III 1, 3, 5, 50, 55 gal. or ASTM D4586 tube 5 gallon pail Proprietary A fibered rubberized adhesive designed for use with modified bitumen membranes. YY"• A thick, fibered, rubberized flashing cmeilt` ...... YYYYYY 'YY YYYYYY A thick, fibered, rubberizgd:Qiing cemgnt for use with modified bitumen membranes. : "": A penetrating solution of solvent and a'b'lend of 0***** Y. Y ..... selected asphalts used to pr6"&e adlnjcq.• ....: ••.YY•Y Y Y . A fibered rubberized adhesive aesignedd'otuse with" • modified bitumen membfWqd5. Y • • • • • • A thick, fibered, rubberized flashing ceftht for use with modified bitumen membranes. A low-VOC, water-based acrylic primer to enhance adhesion of self -adhered membranes. NOA No.: 19-0311,04 Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 4 of 38 APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) Polytherm-H Polyisocyanurate foam insulation Polyglass USA, Inc. Polytherm Polyisocyanurate foam insulation Polyglass USA, Inc. Polytherm G Polyisocyanurate foam insulation Polyglass USA, Inc. XtraFlex Polyiso Polyisocyanurate foam insulation Polyglass USA, Inc. XtraFlex Polyiso G Polyisocyanurate foam insulation Polyglass USA, Inc. ACFoam-II Polyisocyanurate foam insulation Atlas Roofing Corp ACFoam-III Polyisocyanurate foam insulation Atlas Roofing Corp Structodek High Density Fiberboard Roof Wood fiber insulation board Blue Ridge Fiberboard, Inc. Insulation DensDeck, DensDeck Prime Gypsum insulation board Georgia-Pacific Gypsum LLC H -Shield Polyisocyanurate foam insulation Hunter Panels, LLC H -Shield CG Polyisocyanurate/perlite composite insulation ; HVnter )!anal;:LLC ...... ENRGY-3 Polyisocyanurate foam insulation ...Jgl�s Manvi4le*.:Corp.,,,'-, Fesco Board Expanded mineral fiber "';drins Manville Corp •.... • .. Multi -Max FA -3 Polyisocyanurate foam insulation .... .... . . • 4 ax Operating, LLCr.... SECUROCK Gypsum -Fiber Roof Board Fiber reinforced coverboard .. •::jVj;ted Stales- �,ypsunl ....... ...... Corpor.at.ion • . . . . ...... .....• .. . . .. . . NOA No.: 19-0311.04 pIIAMMADE COUNTYJG Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 5 of 38 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Dekfast DF-# 12-PH3 Insulation fastener for wood, SFS Group USA, Inc. steel and concrete decks 2. Dekfast DF-#14-PH3 Insulation fastener for wood, Various SFS Group USA, Inc. steel and concrete decks 3. Dekfast DF-#15-PH3 Insulation fastener for wood, Various SFS Group USA, Inc. steel and concrete decks 4. Dekfast PLT -H-2-7/8 Galvalume hex stress plate. 2'/8" x SFS Group USA, Inc. 31/4" 5. #14 Roofgrip Insulation and membrane Various OMG, Inc. fastener 6. Flat Bottom Metal Plate A2 -SS aluminized steel plate 3" square OMG, Inc. 7. Trufast #14 HD Fastener Insulation fastener for steel and .... A'1tenlo9,.UriAk & (;Q.... wood decks • • t3.�!�In�c. ` 8. Trufast 3" Metal Insulation Round Galvalume AZ50 steel 3.23 round .....). ...;Qltenloh, B;inck &o. Plate plate 3" round •••. U'.'Sjnc. ;"'•; 9. Polygrip Fasteners #12 Insulation fastener for wood Various •:••�olyglas '0SA Inc'':•'. , steel and concrete decks 0000. 0. 0 00000 • .. .. .. 000080 10. Polygrip Fastener # 14 Insulation fastener for wood, Various :'':' Polyglass'fUSA, Inc. •, steel and concrete decks 0 • • •.. • .. 0000.. gogo 11. Polygrip Fastener #15 Insulation fastener for wood, Various Polygia+sWSA, Inc. steel and concrete decks 12. Polygrip Hex Plates Galvalume hex stress plate. 2'/s" x Polyglass USA, Inc 31/4" 13. OMG 3 in. Ribbed Galvalume stress plate. 3" round OMG, Inc. Galvalume Plate (Flat) 14. OMG 3" Galvalume Steel Galvalume stress plate. 3" round OMG, Inc. Plate 15. Dekfast PLT -R-3 Galvalume stress plate. 3" round SFS Group USA, Inc. 16. Millennium One -Step A two component, low rise, Adco Products, Inc. dba Foarnable Adhesive polyurethane foam adhesive Royal Adhesives & Sealants 17. Millennium One Step Green A two component, low rise, Adco Products, Inc. dba Foamable Insulation polyurethane foam adhesive Royal Adhesives & Adhesive Sealants 18. Millennium PG -1 Pump A two component, low rise, Adco Products, Inc. dba Grade Adhesive polyurethane foam adhesive Royal Adhesives & Sealants NOA No.: 19-0311.04 Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 6 of 38 NOA No.: 19-0311.04 Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 7 of 38 APPROVED SURFACING: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Number Product Product Application Specification Manufacturer Name Description Rate 1. Gravel To be installed in a flood coat 400 lbs/sq N/A Generic of approved asphalt at 60 lbs/sq 2. Slag To be installed in a flood coat 300 lbs/sq N/A Generic of approved asphalt at 60 lbs/sq 3. KM Acryl 15 A premium white or tinted 1-1'/z gaUsq ASTM D6083 Polyglass USA, elastomeric acrylic based roof Inc. coating (water-based). A polyester fabric may be used for reinforcement with this coating. 4. KM Acryl 15 QS A premium white or tinted 1-1'/z gaUsq ASTM D6083 Polyglass USA, quick setting, elastomeric Inc. acrylic based roof coating . . • .... ...... (water-based). A polyester •..' ... .' fabric may be used for ...... • .. ...... reinforcement with this """ .... • 5. KM Acryl 25 coating. A premium white or tinted, 1-1'/z gal/sq .... ASTM ID1083 .... . . • .... ..... • Pojyglass i39As • • elastomeric acrylic based roof .. .. .. . ...... Inc. coating (water-based). A . . • polyester fabric may be used . . ...... "•' •' for reinforcement with this • • • • • coating. • • • • 6. KM Acryl 25 QS A premium white or tinted 1-1'/z gaUsq ASTM D6083 Polyglass USA, quick setting, elastomeric Inc. acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 7. KM -PS #220 A single component, solvent, 1.25 gal/sq ASTM D6694 Polyglass USA, white or tinted, silicone Inc. coating. 8. KM -PS #250 A premium grade high solids, 1.25 gal/sq ASTM D6694 Polyglass USA, white or tinted, single Inc. component, moisture cure, fluid applied silicone coating NOA No.: 19-0311.04 Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 7 of 38 APPROVED SURFACING: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Number Product Product Application Specification Manufacturer Name Description Rate 9. PG 300 An asphalt cutback fibered roof 1 %i-2 gal/sq ASTM D4479 Polyglass USA, coating. May be applied by Inc. brush or spray equipment to rejuvenate aged BUR 10. PG 600 Non-fibered aluminum roof %z-1 gal/sq ASTM D2824 Polyglass USA; coating. Type I Inc. 11. PG 650 12. PG 700 13. PG 700 QS 14. PG 800 15. PolyBrite 70 16. PolyBrite 70 QS 17. PolyBrite 90 Fibered aluminum roof coating. 1'/2-2 gal/sq A premium white or tinted elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. A premium white or tinted quick setting, elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. An asphalt based, non-fibered clay emulsion A premium white or tinted elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. A premium white or tinted quick setting, elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. A premium grade high solids, white or tinted, single component, moisture cure, fluid applied silicone coating 1-1'/z gaUsq 1-1'h gaUsq 3 gal/sq in two coats 1-1% gaUsq 1-1 %Z gal/sq 1.25 gal/sq ASTM D2824 Polyglass USA, Type III Inc. ASTM D6083 Polyglass USA, Inc. ASTI.pb083 ASTM D 1227 .... ...... P-491ass U$ -A' • .***Inc. ..... .... % 'FAyglass USA, Inc. ASTM D6083 Polyglass USA, Inc. ASTM D6083 Polyglass USA, Inc. ASTM D6694 Polyglass USA, Inc. NOA No.: 19-0311.04 Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 8 of 38 APPROVED SURFACING: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Number Product Product Application Specification Manufacturer Name Description Rate 18. PolyBrite 95 A single component, white or 1.25 gal/sq ASTM D6694 Polyglass USA, tinted, solvent, moisture cure Inc. silicone coating. 19. POLYPLUS 60 Non-fibered aluminum roof %-1 gal/sq ASTM D2824 Polyglass USA, coating. Type I Inc. 20. POLYPLUS 65 Fibered aluminum roof coating. 1'/z-2 gal/sq ASTM D2824 Polyglass USA, Type III Inc. 21. XtraFlex 60 Aluminum Non-fibered aluminum roof %z-1 gal/sq ASTM D2824 Polyglass USA, Roof Coating coating. Type I Inc. 22. XtraFlex 65 Aluminum Fibered aluminum roof coating. 1'/2-2 gal/sq ASTM D2824 ?&;glass USA, Roof Coating Fibered Type iII '....'Inc. ...... 23. XtraFlex 70 Premium A premium white or tinted 1-1'/z gaUsq ASTMD6083 ...... Wly�ass USA,'. Acrylic FR Roof elastomeric acrylic based roof „� . ...... Inc. Coating coating (water-based). A .... .... ...... polyester fabric may be used .... .... ..... for reinforcement with this ' • " • • • • • • • • • coating. .. .. .. . ...... . 24. XtraFlex 80 Emulsion An asphalt based, non-fibered 3 gal/sq in two ASTM N227 . Po.l}c ... .lass ilSia,:. Roof Coating clay emulsion coats Inc. 25. XtraFlex 30 An asphalt cutback fibered roof 1'/2-2 gal/sq ASTM D4479 rplyglass LISA, Bituminous Roof coating. May be applied by Inc. Coating Fibered brush or spray equipment to rejuvenate aged BUR 26. XtraFlex SRC 8000 A single component, white or 1.25 gal/sq ASTM D6694 Polyglass USA, tinted, solvent, moisture cure Inc. silicone coating. 27. XtraFlex SRC 9600 A premium grade high solids, 1.25 gal/sq ASTM D6694 Polyglass USA, white or tinted, single Inc. component, moisture cure, fluid applied silicone coating NOA No.: 19-0311.04 Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 9 of 38 EVIDENCE SUBMITTED: Test Agency Test Name/Report Factory Mutual Research 4470 Corporation 4450 4470 4470 4470 4470 4450 4450 4470 4470 4470 4470 Trinity ERD TAS 114 TAS 114 TAS 117(B) -ASTM D903 TAS 114 TAS 114 TAS 114 TAS 114 TAS 117(B) -ASTM D6862 TAS 114 & FM 4470 TAS 114(D) — ASTM D 1876 TAS 114 (H) FM 4470 & TAS 114 ASTM D6163 / ASTM D 4601 ASTM D6163 ASTM D6164 TAS 114 TAS 114 & TAS 117 (B) ASTM D6509 ASTM D6222 ASTM D6164 TAS 114 & FM 4474 ASTM D4601 / TAS 117 ASTM D6222 ASTM D4601 / TAS 117 ASTM D6162 ASTM D6162 TAS 114 & FM 4474 TAS 114 & TAS 117 (B) PRI Construction Materials ASTM D6222 Technologies ASTM D6163 ASTM D6222 ASTM D6694 Report No. 2W7A7.AM 2D5A9.AM 3000857 3004091 3001334 3014692 3014751 3019317 3024311 3012321 3036182 RR202591 11752.09.99-1 11751.05.03 020841.06.04 02762.03.05; • • 02764.09.05 " P 1739.01.07"': " P1734.07.06 -RI . • C8500SC.I L(n...' P7860SC. I l bre : • • P10070.10.08* " P 13760.09.09'':' P33970.03.11 • P33960.03.11.9' P37590.03.13 -2-R1 P37590.03.13 -3A P1738.02.07 -R2 11757.04.01-1-R1 P37590.03.13 -1-R1 P37590.03.13 -5-R1 P37590.07.13-1 P41630.08.13 P45940.09.13 P37590.09.13 P45970.05.14 SC5170.05.15 SC5170.12.15-1 PLYG-SC8905.05.16-1 11757.12.00-1-R2 PUSA-061-02-02 PUSA-064-02-02 PUSA-062-02-02 PUSA-134-02-01 Date 08.04.94 06.22.99 01.12.00 01.12.00 02.15.00 08.05.03 08.27.03 06.30.04 11.01.06 07.29.07 07.31.09 10.22.15 02.08.00 05.30.03 .06.02.04 "0940.05 •••••• ..02.(19.05 • 01'73.07 Q%27.07 ;•••• '.1 .30.07 ..... •41.30.07 ••.••' '•10'09.08 ••••;• 0t).10.09 '. �•fl•3!}5.11 • • . 03,15.11 ;""••; ' • WA5.13 03.06.13 04.29.13 04.30.13 06.26.13 07.01.13 07.02.13 08.06.13 09.04.13 09.12.13 05.12.14 05.08.15 12.29.15 05.17.16 04.05.17 01.28.08 02.27.08 12.04.08 05.16.14 NOA No.: 19-0311.04 Mi,aMi•o�e COUNTY', Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 10 of 38 r EVIDENCE SUBMITTED: Test Agency Test Name/Report Report No. Date ASTM D6694 PUSA-135-02-01 05.16.14 TAS 117(B) PUSA-202-02-01 05.08.17 FMA470 & TAS 114 PUSA-202-02-02 05.23.17 NOA No.: 19-0311.04 Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 11 of 38 sees . sees 0.98.0 .9 . •e• . . sees.. seessees . . 0000 sees 00.46 .. .. 0000 0000.9 sees.. 9 . . . . ,:909. sees .. .. sees.. .0 . . .. 9.9. NOA No.: 19-0311.04 Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 11 of 38 4 S, % Membrane Type: SBS/APP Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24" spans with 8d common nails at 4" o.c. or #8 wood screws at 6" o.c. System Type E(1): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Elastobase, Elastobase P, Elastoshield HT, Polyanchor, XtraFlex SBS Glass Base or XtraFlex SBS HT Base 650 fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8" diameter tin caps spaced 8" o.c. in a 4" lap and 8" o.c. in three equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V PLUS, Elastoflex SA V PLUS FR or XtraFlex SBS Base SA self -adhered. Membrane: One ply of Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, Polyflex SA P FV. P.Olyfresko G APP SA, Polyfresko G APP SA FR, Polyfresko G SBS SA, Poly jtes%(g G SB5 SA FR, 000000 PolyKool, Polyreflect, XtraFlex APP G SA, XtraFlex Kool APP S SA'or KtraFlex•SBS G SA .' self -adhered. • 0 : 0 0 . •• 6666.9 6666.. Surfacing: 6666 66660. 6666 Install one of the approved surfacing products listed in Table 4 to obtai"desired ZQjjftg or (Optional) • • required fire classification. 000000 6 9 0 • 6 6 66 • • 90 60 •9 . 6666.. Maximum Design :60:0: • • Pressure: -52.5 psf; (See General limitation #7.). • 6666.. ""• • • 0 0 . 0 :6090 6. 0 NOA No.: 19-0311.04 Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 30 of 38 r WOOD DECK SYSTEM LIMITATIONS: A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. 0000 Note: Spot attached systems shall be limited to a maximum design pressure of 4fi psf. 00#090 0000 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force. (F) value of 275 lbf., as • tested in compliance with Testing Application Standard TAS 105. If the fastener valut,•Al fitld-tested a;e below..:. 275 Ibf. insulation attachment shall not be acceptable. • ....... ...... 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attach ftV4 l.g based on a minimum • fastener resistance value in conjunction with the maximum design value listed within &.Sffific sys�In.• Shoula*: • •. the fastener resistance be less than that required, as determined by the Building Officio}, a revised Tzsthu2r • • • spacing, prepared, signed and sealed by a Florida registered Professional Engineer, R4gitt2*d Architect, or . • Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the witblkavW • • • • : • resistance value taken from Testing Application Standards TAS 105 and calculations'Ilip;rppliance with Rool%g• .; Application Standard RAS 117. • 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 19-0311.04 MIAMI•DADE COUNTY • Expiration Date: 10/11/22 Approval Date: 03/21/19 Page 38 of 38 POLYGLASS E -.S A.. lac. Corporate OI'tice. I I I I West Nev,. port Center Dri ve Deerfield reach. Honda ;3)..1,47 10. o�A)'.13 13.0- (9`i)T18--14 3 I;rnail: technicalirlpokilass.coi» Technical Bulletin 2018-01 To: All POLYGLASS Users CC: POLYGLASS Sales & Technical Services Personnel Date: January 2, 2018 From: James E. Akins, CSI National Technical Services Manager RE: NEWLY Revised Polyglass Self -Adhered UL Listing for Class A assemblies • • • This Notice is to inform all parties that Polyglass USA, Inc. recently receiv{g4 AEWLY•. REVISED Class A, Combustible Fire Rating within Polyglass TGFU.R1475t�f4-slopes , • • up to 2:12. The NEW UL, Class A assembly, System #49, is listed below. •"••• ,'••• •••• • 49. Deck: C-15/32 Incline: 2 Insulation (Optional): — Polyisocyanurate, perlite, wood fiber or :•':•: • polyisocyanurate/perlite board, any thickness. y : •..;, Base Sheet: — "ELASTOBASE", mechanically fastened or "ELASTAPLrX Sd V FR", self -adhered. • • Ply Sheet (Optional): — "ELASTOFLEX SA V PLUS FR", "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT", self -adhered. Membrane: — "POLYFLEX SA P FR", "POLYFRESKO G APP SA P FR", "ELASTOFLEX SA P FR", "POLYFRESKO G SBS SA P FR", self -adhered or "DUFLEX G FR", "XtraFlex APP Dual", "POLYFLEX G FR", "XtraFlex APP G HP", "Xtraflex APP G FR", "ELASTOFLEX S6 G FR", "POLYFRESKO G SBS FR", "ELASTOFLEX VG FR", "XtraFlex SBS POLY G", "XtraFlex SBS POLY G T", "XtraFlex SBS GLASS G", "XtraFlex SBS GLASS GT" or "ELASTOSHIELD TS G FR", heat fused. The newly populated assembly allows our users to adhere directly to combustible substrates, without the overburden of extra glass base plies, as previously listed. Should a project have a specific or special circumstance, please direct all questions to the POLYGLASS Technical Services Department or a Code and Compliance Representatives. JEA,1/2/2018 1100FINC; AND tV.AJEJITROOFING SYSTEMS .MAPf1