MC-19-1487Permit NO.: MC -06-19-1457
Miami Shores Village Permit Type: Mechanical - Residential
10050 NE 2 Ave
Miami Shores FL 33138 I Work Classification: A/C Replacement
305-795-2204 1 Permit status: Approved
issueoatei,07/16/2019I Expiration: 01/13/2020
Location Address Parcel Number
10550 NE 3RD CT, Miami Shores, FL 33138 1122310130320
Contacts
NICOLAS PISANO Owner AIR SYSTEMS A/C LLC Contractor
10550 NE 3 CT, MIAMI SHORES, FL 331382010 ROY VASQUEZ
2345 W 80 ST 1, HIALEAH, FL 33016
Business: 7862083484
Ins ection
Description: A/C CHANGE OUT Valuation: $ 4,151.00 Requests:
4949
Total Scl Feet: 0.00
Fees
Amount
Application Fee - Other
$50.00
CCF
$3.00
DBPR Fee
$2.18
DCA Fee
$2.00
Education Surcharge
$1.00
Permit Fee
$95.29
Scanning Fee
$3.00
Technology Fee
$3.63
Total:
$160.10
Building Department Copy
Payments
Date Paid Amt Paid
Total Fees
$160.10
Check # 10490
07/16/2019 $110.10
Check # 10482
06/27/2019 $50.00
Amount Due:
$0.00
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNER AF IDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
regulatio cons uction and zoning. Futhermore, I authorize the above named contractor to do the work stated.
/ Applicant / Contractor / Agent
July 16, 2019
Date
Page 2 of 2
Miami Shores Village
Cod Building Department
artment
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
BUILDING
PERMIT APPLICATION
F7, BUILDING ❑ ELECTRIC ❑ ROOFING
❑PLUMBING ® MECHANICAL F—] PUBLIC WORKS
BY�JUNI2 7)019
FBC 201
Master Permit NJA& ` l& n
Sub Permit No.
❑ REVISION ❑ EXTENSION ❑ RENEWAL
❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: /6550 A16 ,3 d
City: Miami Shores County: Miami Dade Zip: 83138
Folio/Parcel#:d/�1�3 - 0320 Is the Building Historically Designated: Yes NO
Occupancy Type4&S; dA: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): /V / alm A. 7;6&" Phone#: 3os - 4� —SpSp
Address:_jZ$2 5 AaMi A/,L A 402- 2
City: _�wtz State: TL Zip: 33 -30
Tenant/Lessee Name: Phone#: 305-5,q6-38360
Email: �j
CONTRACTOR: Company Name: _Ak Svsfe 8 /`�ic� wl� Phone#: 3�J'4o$(- ID .a_
Address: _�W8 I�iW l33 S7-
City: a State: �� Zip: 330,5`7
Qualifier Name: �_j/ f Phone#:
State Certification or Registration #:
DESIGNER: Architect/Engineer:
Address:
Value of Work for this Permit:
Type of Work: ❑ Additior
Description of Work:
❑ Alteration
Specify color of color thru We:
Submittal Fee
$_ �1APermit Fee $
Scanning Fee $
Technology Fee
Structural Reviews $
(Revised02/24/2014)
Radon Fee $
Certificate of Competency #:
one#:
City: State
4 Square/Linear Footage of Work:.
New ,Repair/Replace
Training/Education Fee $
CCF $
DBPR $
Zip:
❑ Demolition
CO/CC $ _
Notary $.
Double Fee $ _
Bond $
TOTAL FEE NOW DUE $.L0y
,90
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature \ 0�,�
OW ER or AGENT
The foregoing instrument was acknowledged before me this
day of , 20 �� by
who is personally known to
llor who has produced as
identification and who did take an oath.
NOTARY
Signature 7p, 4
7CONTRACTOR
The foregoing instrument was acknowledged before me this
_ day of 20 11 by
who is personally known to _
m�,or who has produced as
identification and who did take an oath.
NOTARY P
Sign: Sign:
Print: Print:
Seal: Seal:
DANAY MOISES
sNOtery Public -State of Florida
Commission ft GG 003831
My Com'rutm' ig0�
APPROVED BY Rla Examiner
Structural Review
(Revised02/24/2014)
DANAY MOISES
:Notary Public -State of Florida
Commissionp GG 003831
My Commission Ex area
****
Zoning
Clerk
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax:(305) 756.8972
AIR CONDITIONING REPLACEMENT DATA
PERMIT NUMBER: MC
This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must
be on its own data sheet. Multiple units on single sheets are not acceptable.
Job Address (where the work is being done): o!r 0 AIC 3 GT
City: Miami Shores Village County: Miami Dade Zip Code:
ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB
ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION
A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS
AHRI DATA SHEET REQUIRED
Change disconnecting means: YES ❑ NO 5j] ARHI Sheet Attached: YES ® NO ❑ Contract Attached: YES
1. Minimum Circuit Ampacity (Wire Size): — 19. � 9
2. Maximum Overcurrent Protection (Fuse/Breaker Size): 30 kM hS
3. Voltage of Circuit (208/240/480):7/ 7,
4. Size Disconnecting Means: 30 _
Contractor's Company Name: A& &Vt Phone: 3V5'--�a$f -1Diia
State Certificate or Re ' tration No.'s"55W Certificate of Competency No.
Signature Date: b�zy�q
(Qualifi is signature)
(Revised02/24/2014)
UNIT BEING REPLACED
DATA
NEW UNIT
Z44 4 P X
MANUFACTURER
. ;A
(!830"-
�ZE
AHU or PKG. UNIT MODEL #
/ 1/,5 14 D
3 (o
SZ(o -036 —ZP
COND. UNIT MODEL#
V493
pre
/
og 4t/
KW HEAT
Q
3 o- ^
NOM TONS
3 7
-on
AHU
CU PKG
1) M.C.A
AHU
CU
PKG
AHU
CU PKG
2) M.O.P
AHU
CU
PKG
AHU
CU PKG
3) VOLTS
AHU
CU
PKG
PKG UNIT / /
PKG UNIT
EER/SEER
YES
NO
REPLACING DUCTS
YES
NO
YES
NO
REPLACING THERMOSTAT
NO
YES
NO
NEW 4"CONCRETE SLAB
YES
elroD
YES
NO
NEW ROOF STAND
YES
N
YES
NO
NEW RETURN PLENUM BOX
YES
NO
1. Minimum Circuit Ampacity (Wire Size): — 19. � 9
2. Maximum Overcurrent Protection (Fuse/Breaker Size): 30 kM hS
3. Voltage of Circuit (208/240/480):7/ 7,
4. Size Disconnecting Means: 30 _
Contractor's Company Name: A& &Vt Phone: 3V5'--�a$f -1Diia
State Certificate or Re ' tration No.'s"55W Certificate of Competency No.
Signature Date: b�zy�q
(Qualifi is signature)
(Revised02/24/2014)
i
ACORL® CERTIFICATE OF LIABILITY INSURANCE
DATE (MMIDD/YYYY)
`...�"
06127/2019
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED
REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(les) must have ADDITIONAL INSURED provisions or be endorsed.
If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on
this certificate does not confer rights to the certificate holder in lieu of such endorsement(s).
PRODUCER
Safe Insurance Group
CONTACT
Soraya Hernandez
PHONE FAX
N e ; (305)264-8964 (acro): (305)267-1576
7901 NW 2nd St.
E-MAIL
ADDRESS:__ soraya@safeinsgroup.com --
Miami, FL 33126
_---
License #: A161532
INSURERS AFFORDING COVERAGE NAIC #
INSURER A: United Specialty
CLAIMS -MADE a OCCUR
INSURED AIR SYSTEMS A/C, LLC
INSURER B:
DBA AIR SYSTEMS A/C
INSURER C:
DAMAGE TO RENTED
PREMISES Ea occurrence $ 100,000
4698 NW 133 ST
INSURER D:
Opa Locka, FL 33054
INSURER E:
INSURER F:
COVERAGES CERTIFICATE NUMBER: 00000000-0 REVISION NUMBER: 114
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
INSR
LTR
OF INSURANCE
ADDLTYPE
IVSD
SUER
POLICY NUMBER
EFF
MMIDDPOLICY/YYYY
LICY EXP
MIDD1YYYY
M
LIMITS
A
X COMMERCIAL GENERAL LIABILITY
DCG07257-01
06/27/2019
06/27/2020
EACH OCCURRENCE $ 1,000,000
CLAIMS -MADE a OCCUR
DAMAGE TO RENTED
PREMISES Ea occurrence $ 100,000
MED EXP (Any one person) $ 5,000
PERSONAL & ADV INJURY $ 1,000,000
GENT AGGREGATE LIMIT APPLIES PER:
GENERAL AGGREGATE $ 2,000,000
X POLICY JE0 F7LOC
PRODUCTS - COMP/OP AGG $ 2,000,000
$
OTHER:
AUTOMOBILE LIABILITY
COMBINED SINGLE LIMIT $
Ea accident
lANY AUTO
BODILY INJURY (Per person) $
OWNED SCHEDULED
AUTOS ONLY AUTOS
I HIRED NON -OWNED
_ AUTOS ONLY AUTOS ONLY
BODILY INJURY (Per accident) $
PROPERTY DAMAGE $
Per accident
$
(_
UMBRELLA LIAB OCCUR
EACH OCCURRENCE $
AGGREGATE $
EXCESS LIAB CLAIMS -MADE
DED RETENTION $
$
WORKERS COMPENSATION
AND EMPLOYERS' LIABILITY Y / N
PER OTH-
STATUTE ER
ANY PROPRIETOR/PARTNER/EXECUTIVEE.L.
EACH ACCIDENT $
OFFICER/MEMBER EXCLUDED? ❑
N / A
(Mandatory in NH)
E.L. DISEASE - EA EMPLOYE $
If yes, describe under
DESCRIPTION OF OPERATIONS below
E.L. DISEASE - POLICY LIMIT $
DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required)
Subject to policy form, conditions, endorsements, limitations and exclusions
air conditioner sub contractor
JOB REFERENCE: MECHANICAL CONTRACTOR QUALIFIER ROY VAZQUEZ CAC033544
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
VILLAGE OF MIAMI SHORES THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS.
10050 NE 2ND AVE
Miami Shores, FL 33138 AUTHORIZED REPRESENTATIVE
SDH
988-2015 A RD C ORATION. All rights reserved.
ACORD 25 (2016/03) The ACORD name and logo are re Bred marks of ACORD
'Printed by SDH on June 27, 2019 at 11:02AM
6/24/201,9
Insurance Services
ACORD® CERTIFICATE OF LIABILITY INSURANCE
DATE (MM,DD1rOY)
0684/2019
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED
REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed.
If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement A statement on
this certificate does not confer rights to the certificate holder in lieu of such endorsement(s).
PRODUCER
CUNIALI
NAME:
Automatic Data Processing Insurance Agency, Inc.
PHONE IExt: (AIC, Noy
ADDRESS:
INSURER(S) AFFORDING COVERAGE NAK n
1 Adp Boulevard
Roseland NJ 07068
INSURER A: NorGUARD insurarxe Company 31470
INSURED
INSURER B
AIR SYSTEMS AC LLC
INSURER C:
4698 NW 133RD ST
INSURER D:
INSURER E:
AUTOMOBILE LIABILITY
ANY AUTO
OWNED SCHEDULED
AUTOS ONLY AUTOS
HIRED NONOWNED--
AUTOS ONLY AUTOS ONLY
Opa Locka FL 33054
INSURER F:
COVERAGES CERTIFICATE NUMBER: 1196320 REVISION NUMBER:
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT. TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAYBE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJ ECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES, LIMITS SHOWN MAY HAVE BEEN RE DUCED BY PAID CLAIMS.
LTR
TYPE OF INSURANCE
INSD
WVD
POLICY NUMBER
(MMIDD;YYYY)
(MM)DDIYYYY)
LIMITS
COMMERCIAL GENERAL LIABILITY
CLAIMS+IADE 1-1 OCCUR
�!.�� I I� •••.
EACH OCCURRENCE S
KLN
PREMISES tEa occurrence) S
MED EXP (Anyone persona S
PERSONAL &ADV INJURY S
GEN'L AGGREGATE LIMIT APPLIES PER.
POLICYr-1 I P€GI' RQ LOG
OTHER.
GE NERAL AGGREGATE S
PRODUCTS-COMPCP AGG S
S
AUTOMOBILE LIABILITY
ANY AUTO
OWNED SCHEDULED
AUTOS ONLY AUTOS
HIRED NONOWNED--
AUTOS ONLY AUTOS ONLY
LUaccident) I S
BODILY IN) URY (Per person) S
BODILY INJURY (Per accident) S
S
(Per accidenU
5
UMBRELLA LIAR
EXCESS LIAR
HCLAIMS-MADE
OCCUR
EACH OCCURRENCE s
AGGREGATE S
DED I I RETENTIONS
S
A
WORKERS COMPENSATION
ANDEMPLOYERS'LIABILITY
ANY OFFICER lEMBEEREXCLUDEpiECUTIVE YIN
(Mandatory in NH)
II yes. descritte under
DESCRIPTION OF OPERATIONS below
N
AIWC070340
05/16/2019
05/16/2020
-
STATUTE ER
E.L.EACHACCIOENT S 1.000,000
E.L. DISEASE -EA EMPLOYEE S 1,000,000
E.L. DISEASE -POLICY LIMIT S 1 I)�
DESCRIPTION OF OPERATIONS 1LOCATIONS (VEHICLES (ACORD 101. Additional Remarks Schedule, may be attached it more space Is required)
JobReference. Building Department
Contractor License: QUALIFIER ROY VAZQUEZ CAC033544
CERTIFICATE HOLDER CANCELLATION
031988-2015 ACORD CORPORATION. All rights reserved.
ACORD 25 (2016,03) The ACORD name and logo are registered marks of ACORD
https://adpia.adp.com/ISExternal/app/index.html?clientid=2965733&requestFrom=run#/pc 1/1
SHOULDANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
Village Of Mianti Shores
ACCORDANCE WITH THE POLICY PROVISIONS.
10050 NE 2nd AVE
AUTHORIZED REPRESENTATIVE
Mianr S hores FL 33138
�!.�� I I� •••.
031988-2015 ACORD CORPORATION. All rights reserved.
ACORD 25 (2016,03) The ACORD name and logo are registered marks of ACORD
https://adpia.adp.com/ISExternal/app/index.html?clientid=2965733&requestFrom=run#/pc 1/1
MI! 14411 11 7
AHRI Certified Reference Number : 10221129 Date : 06-21-2019
AHRI Type: RCU-A-CB
Series: DX14SA
Outdoor Unit Brand Name : DAIKIN
Outdoor Unit Model Number (Condenser or Single Package) : DX14SA0361A*
Indoor Unit Model Number (Evaporator and/or Air Handler) : DV39PTCC14A*
Region : Southeast and North (AL, AR, DC, DE, FL, GA, HI, KY, LA, MD, MS, INC, OK, SC, TN, TX, VA, AK, CO, CT, ID, IL,
IA, IN, KS, MA, ME, MI, MN, MO, MT, ND, NE, NH, NJ, NY, OH, OR, PA, RI, SD, UT, VT, WA, WV, WI, WY, U.S.
Territories)
Region Note : Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions
until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for00
..
which they meet the regional efficiency requirement. 0.0 0000
The manufacturer of this DAIKIN product is responsible for the rating of this system combination. 00 : 0 0
•••• •• •
• • • • •
Rated as follows in accordance with the latest edition of ANSI/AHRI 210/240 with Addenda 1;and 2, Performance Va$ng of UMtary000006'
Air -Conditioning & Air -Source Heat Pump.Equipment and subject to rating accuracy by AHRI-sponsored, indegeo2 nt!ttiird party te�ting:
Cooling Capacity(A2)- Single or High Stage (95F), btuh 34200 ;'';'; •
.. •: • • •
SEER: 14.50
EER (A2) - Single or High )3tatge (95F) : 11.50
uN � 7 zQI4
$Y:
t r --- - r'�� �_ (fib � 1 � � J •
9`711 1t" rCS Vi 1,-9
BY DATE
91 JG C)FPT
5Ut3,tCT IO CGNIPLIANCE WI A ALL FEUERAL
STA: E ANj U(,I.)N 'f riUL._S AND REGULATIONS
t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being
marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still
selling or offering for sale.
Ratinas that are accompanied by WAS indicate an involuntary re -rate. The new Dublished ratina is shown alona with the Drevious (i.e. WAS) ratino.
DISCLAIMER
AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the
unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the
directory at www.ahridlrectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and
confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated;
entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, ma -11
personal and confidential reference. AIR-CONDITIONING, HEATING,
CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE
The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link we mal,o IH 1,ejwr
and enter the AHRI Certified Reference Number and the date on which the certificate was issued,
which is listed above, and the Certificate No., which is listed at bottom right.
132056058947624115
©2019Air-Conditioning, Heating, and Refrigeration Institute ! CERTIFICATE NO.:
E�*�,iGfNEER1t`�.IC-
EXPREE'� c'
E.x.P.E.R.T.. (Engineering Express Product Evaluation Report)
160 SW 12TH AvE SUITE 106, DEERFIELD BEACH, FL 33442
(954) 354-0660 1 ENGINEERINGEXPRESS.COM
Technical Evaluation Report
DIVISION: 23 08 00—COMMISSIONING OF HVAC
THIS DOCUMENT CONTAINS (5) PAGES: THE FIRST PAGE MUST BEAR AN
ORIGINAL SIGNATURE & SEAL OF THE CERTIFYING PE TO BE VALID FOR USE
(Issued March 1616, 2016 Subject to Renew March 15tH, 2017)
REPORT HOLDER:
DAIKIN MANUFACTURING COMPANY, L.P.
5151 SAN FELIPE STREET re-DAIKIN
HOUSTON, TX 77056, USA
877-254-4729 1 DAIKINCOMFORT.COM
SCOPE OF EVALUATION (compliance with the following codes):
THIS IS A STRUCTURAL (WIND) PERFORMANCE EVALUATION
ONLY. NO ELECTRICAL OR TEMPERATURE PERFORMANCE
RATINGS OR CERTIFICATIONS ARE OFFERED OR', IMPLIED HEREIN.
This Product Evaluation Report is being issued in accordance with the
requirements of the 5th Edition Florida Building Code (2014) per FBC
Section 104.11, FMC 301.15, FBC Building Ch. 16, ASCE-7-10, FBG
Existing Building sections 701.1, 706.6.1. FBC Building 1522.2, and FBC
Residential M1202.1, M1301.1, FS 471.025, including Broward County
Administrative Provisions 107.3.4. The product noted on this report has
been tested and/or evaluated as summarized herein.
IN ACCORDANCE WITH THESE CODES EACH OF THESE
REPORTS MUST BEAR THE ORIGINAL SIGNATURE & RAISED
SEAL OF THE EVALUATING ENGINEER.
SUBSTANTIATING DATA:
• Product Evaluation Documents
Substantiating documentation has been submitted to provide this TER and
is summarized in the sections below.
• Structural Engineering Calculations
Structural engineering calculations have been prepared which evaluate the
product based on comparative and/or rational analysis to qualify the
following design criteria:
• Maximum allowable unit panel wind pressire connection
integrity
• Maximum allowable uplift, sliding, & overturning moment
for ground and roof applications
Calculation summary is included in this TER and appears below.
NOTE: No 33% increase in allowable stress has been used in the
design of this product. Microsoft Excel was used to carry out the
calculations present in this report.
INSTALLATION:
The product(s) listed above shall be installed in strict compliance with this
TER & manufacturer -provided model specifications.
The product components shall be of the material specified in the
manufacturer -provided product specifications. All screws must be installed
in accordance with the applicable provisions & anchor manufacturer's
published installation instructions.
LIMITATIONS & CONDITIONS OF USE:
Use of this product shall be in strict accordance with this TER as noted
herein. See final page for complete limitations and conditions of use,
OPTIONS:
This evaluation is valid for all DAIKIN models present in the table located
on the final page.
FINISH:
Baked enamel.
NOTE: GRAPHICAL DEPICTIONS IN THIS REPORT ARE FOR
ILLUSTRATIVE PURPOSES ONLY AND MAY DIFFER IN APPEARANCE
UNIT CASING MATERIAL:
26ga galvanized sheet steel ASTM A653 CS coldrolled'sieels for side
covers. 22ga galvanized sheet st4l A$TW A653 Cb'd killed steLl•"• •
bottom base pan. 209a galvanized sh2bfste2l ASTM A663 @old rolled steal "
for top panel. Removable top & sidesw*ew secured 11 :10-12 •
metal screws. 0940,90 • •
Knockouts provided for utility & contra jor1pections.. • 0 • • • • • .
INSTALLATION: "" ' • • • • • •
Shall follow manufacturer specificatiMft."V II as the „nfonn•tion prc»rk :v.'
• •
herein. •• •• •• 0000..
0000•• .
STRUCTURAL PERFORMANCE:*
• '.
Models referenced herein are subject to the followh,;.V:iQn IimitMfblM11• •
ASCE-710 Exposure Categories C ; • • • • • •
•.....
Up to and including 175mph (Vult) foI•Kp to000' MRH`".h1VHZ`"`
Up to and including 170mph (Vult) for up to 260' M1IJ*g,4\?HZ`"
Up to and including 200mph (Vult) for up to 200' MRH**. Non-HVHZ`**
Ground or Roof Application per installation instructions
"Mean Roof Height **'High Velocity Hurricane Zone
Maximum Rated Wind Pressure:
193psf Lateral 93psf Uplift (le. Dead Load)
Site specific wind analysis may produce alternate limitations provided
maximum rated wind pressure is not exceeded.
ORIGINAL SIGNATURE AND RAISED SEAL
REQUIRED TO BE VALID PER CODE:
Frank L. Bennardo, P.F.;
ENGINEERING EXPRE556
PE #0046549 CA #9885
The FBC 14 defines APPROVED SOURCE (Section 2:2) as: `Anindependent person. 5rm or corporation, approved by the boiidmg official, who is competent and experienced in the appiica6en o' eng:neBcng
principles to matena{s. methods or systems analyses," Engineering Express"` professionals meet the competency requirements as defined in the FEC and can sea? their w,,,rk. Eogineedag Express+', regulany
enga,led in conducting and providing engineering evaluations of single element and full-scale building systems tests.
DAIKIN SPLIT SYSTEMS Engineering Express° I TER -16-3146.2
SECTION 2 PRODUCT INSTALLATION
Condens
Roof or ground
structure / subs
(concrete, steel
schedule below)
TIE -DOWN STRAP & CLIP SCHEDULE
in clips. See
>elow for
ations
Cabinet
*
Roof Height
lie -down Strap WLL
Straps {lbs)
Tie -down
Clips per
Side
Al
Ground
0
NA
1
Up to 60' (80') 2 300
1
Up to 220' (150') 2 300
1
Up to 200'(250') 2 400
1
81, 62
Ground
0
NA
1
_
Up to 60'(80') 2 400
1
Up to 120'(150') 2 400
2
Up to 200'(250') 2 400
2
Cl, C2, C3,
C4, CS
Ground
0
NA
1
Up to 60'(80') 2 400
2
Up to 120' (150') 2 500
2
Up to 200'(250') 2 600
2
Dl, D2, D3,
D4, DS, D6
Ground
0
NA
1
Up to 60'(80') 2 800
2
Up to 120'(150') 2 1000-�—
2
Up to 200'(250') 2 1000
B
ANCHOR TO HOST STRUCTURE SCHEDULE
Cabinet
Ground or Roof
Height*
Concrete
3,000 Psi
Anchor Type
1/fr{ Min
1/8" Min 6061-T6
A36 Steel Atuminu
m
Al
Ground
A
N/A
N A
U to 60' 80' B
B
U to 120' 150' NIA B
B
U to 200' 250' N/A 8
8
81, 62
Ground
A
NIA
N A
U to 60' 80' N/A B
8
to 120 150' N/A 8
B
UP to 20V50' N/A
C1, C2, C3,
C4, C5
Ground
N/A
N A
U to 60' 80' N A B
8
U to 120' 150' N A B
Uo to 200'(2`01) N B
B
Dl, D2, D3,
D4, D5, D6
U to 60' 80' N A B
U0 to 120'(15011 B
1 Uv to 200'[250')
B
TIE -DOWN CLIP
(GROUND APPLICATION)
ASTM A653 G60 galvanized cold
rolled steel 0.072" thick for all
cabinets tied down at ground
(Goodman Bracket); fasten cabinet
using (2) anchors per clip from
Anchor to Host Structure Schedule
Table. Clip integrates into base pan
slot.
TIE- DOWN CLIP
(GROUND AND ROOF APPLICATION)
Miami Tech CUTD 1" wide and any
length ASTM A653 galvanized steel
0.07" thick for all cabinets tied down to a
roof structure; fasten clip to structure
using anchor from Anchor Schedule to
Host Structure Table and (2) #10 x 318"
SS 410 self -drilling screw to fasten clip
to unit base pan. See Tie -down Strap &
Clip Schedule Table for clip amount. For
ground appiicationess Iiie-down clip
schedule, correspbp4iagtb 60' he,4$. • • .
Tie -down Strap& Clip Type: (for roof appIlc%tic(h:)• • • • • • • • • • •
Working Load Limit (WILL) is strap's manufactuigfg Specified qej strap. A mini T err • •
strap width of 1" and minimum length of 15 ftPiss req uiftd for all ca*inets.
%as
Clips heights shall be adequate to fit SMS withine pan heitht. Verify heigh"*iRr' •
Clips shall be placed at center on each side Anti�Qny spac". •• 0 Goo**
Cross member shall be added and fixed to robist*wl see detail A. .. • • • •..
• • • • • •
•
•
•
The value shown in•parenthese9 iaicaies the*
allowable roof height in 170mph conditions NO. 60'(80')
indicates an allowable roof height of 60' for 175mph or
80' for 170mph Vult.
Note:
Tie -down straps shall be wrapped around unit and roof stand rail, and shall be
tightened using the buckle. Provide two straps per unit.
Strap material shall be high strength webbing and shall be compliant for exterior
grade use if they contain plastic components, per FBC chapter 26. Select strap
from table based on WLL requirements. For Non-HVHZ, use (2) straps with
minimum WILL of 500lbs each, up to 200' MRH.
Anchor Types to Host Structure:
A. – 1/4" ELCO ULTRACON SS4 Anchor embedded 3" in 3,000 psi
concrete. 2 112" from edge minimum. NOA No. 15-0226.11
B. – 1/4' -20 UNC SAE Grade 5 screw min. 1/2" from edges with nut and
washer OD 0.75"
NA. - No anchors apply.
IN ALL CONDITIONS IT IS THE RESPONSIBILITY OF THE PERMIT HOLDER TO ENSURE THE HOST STRUCTURE 1$ CAPABLE OF
WITHSTANDING THE RATED GRAVITY, LATERAL, AND UPLIFT FORCES BY SITE-SPECIFIC DESIGN. NO WARRANTY OF ANY KIND,
EXPRESSED OR IMPLIED, IS OFFERED BY ENGINEERING EXPRESS AS TO THE INTEGRITY OF THE HOST STRUCTURE TO CARRY
DESIGN FORCE LOADS INCURRED BY THIS UNIT.
ENGINEERING EXPRE>So 160 SW 12`11 AVE, SUITE 106 DEERFIELD BEACH, FL 33442 Page 2
(5354 354-0660 ENGINEERING EXPRESS.COM
DAIKIN SPLIT SYSTEMS Engineering Express' I TER -16-3146.2
STRAP AND CLIP LAYOUT
YPICAL ?CLIP
ONFIGURATION
�/ '
SIE ANCHOR TO HOST
STRUCTURE SCHEDULE
\ OR SEE DETAIL A
/
STRAPS SEE TIE -DOWN
--- -
STRAP & CLIP SCHEDULE
MIAMI TECH CUTD
SEE TIE -DOWN
STRAP & CLIP SCHEDULE
CROSS MEMBER
6061-T6 ALUMINUM
2" X 2' Y4"
ROOF STAND RAIL
_ IPER
B
SEPARATE
ENGINEERING
�A
/';' STRAP AND CLIP LAYOUT
SCALE: N.1.5.
FLM VIEW
UNIT
ROOF STAND RAIL
PER SEPARATE
ENGINEERING
UNIT
ROOF STAND RAIL
PER SEPARATE
ENGINEERING
'A*N 1 AND 2 CLIP CONFIGURATIONS
SCALE: N.T.S. DETAIL VIEW
3"
c CROSS MEMBER FRONT VIEW
SCALE: N.T.S. A:C 7 VIEW
MIAMI TECH CUTD SEE
TIE -DOWN STRAP
& CLIP SCHEDULE
BASE PAN
(2) #10 x %' SS 410 SMS
(2) #14.18 SS 410 SMS
e" SS 410 WITH
WASHER & NUT
CROSS MEMBER
6061-T6 ALUMINUM
2'X2"XY"
2 STRAP AND CLIP LAYOUT
SCALE: N.T.S. ELEVATION KIEV.'
STRAPS SEE TIE -DOWN
STRAP & CLIP SCHEDULE
HORIZONTAL STRAP SEE
PANEL INTEGRITY FOR
STRAP SPECIFICATION
MIAMI TECH CUTD SEE
TIE -DOWN STRAP & CLIP
SCHEDULE
ROOF STAND RAIL
PER SEPARATE
ENGINEERING
C&RQVMEMBER.....
• • • 6061-T6 ALUMINUM •
•
0000••
UN•• • 0000••
-. "�-- — IT
0000•• • • •
0000••
I 0000 i*%#1'%18STAIKLESS •
` ir, a 4 ��•� • STW3i410SHEF=•••
�_ 0000•• •jolk7ALOSCREW•
00:0 •
• • Ts • — ROOF STAND F&1L• • • •
0 0 0 0 0• PER SEPARATE ••
0 '• 0 • ENGkVEERING • • • • •
•0000•
B SCREWS AT CROW MEMBER . • • • • •
SCALE: N.T.S. DETAIL VIEW • •
D CROSS MEMBER SIDE VIEW
SCALE: N.T.S. SECTION NEW
BASE PAN
(2) #10 x N8"
SS 410 SMS
(2) #14-18
SS 410 SMS
'!4" SS 410 WITH
WASHER & NUT
CROSS MEMBER
6061-T6 ALUMINUM
2"X 21XY"
ROOF STAND RAIL
PER SEPARATE
ENGINEERING
Note: Installers must ensure that screws used to fasten the tie -.down clips with the unit base pan do not touch the coil preventing any damage.
ENGINEERING EXPRESSe 160 SW 12111 AVE. SUITE 106 DEERFIELD BEACH, FL 33442 Page 3
(954) 354-0660 ENGINEE RING EXPRESS.COM
DAIKIN SPLIT SYSTEMS Engineering Express° I TER -16-3146.2
see
SECTION 4 SUPPORTING CALCULATIONS & SUMMARY
FORCES SUMMARY
Cabinet
Outside Dimensions
Weight
Range
(lbs)
Ground
or Roof
Height*
Lateral
Pressure
(Psf)
Uplift
Pressure
(Psf)
Max
Force
(Ibs)
Max
Overturn
(lbs -in)
Max
Tension
(lbs)
Uplift
Force
(Ibs)
D (in) (in) (in)
W H
Al
23.0
210
25.7
102
Ground
42.7
0
175.6
2261.5
83
0
23.0 23.0 25.7
60' (80') 151.0 73 621.2 7998.0 503.2
268.5
23.0 23.0 25.7
120 (150') 173.7 84.0 714.4 9197.8 585.6
308.8
23.0 23.0 25.7
200' (250') 192.9 93.4 793.5 10216.4 655.5
343.0
B1, B2
26.0
26.0
32.5
103-131
Ground
42.7
0
250.6
4072.4
137
0
26.0 26.0 32.5
60' (80') 151.0 73 886.3 14402.6 752.3
343.1
26.0 26.0 32.5
120' (150') 173.7 84.0 1019.3 16563.2 1 874.0
394.6
26.0 26.0 32.5
200' (250') 192.9 93.4 1132.2 18397.5 977.3
438.3
Cl, C2, C3, C4, C5
29.0
29.0
40.0
142-184
Ground
42.7
0
344.0
6880.7
209.7
0.0
29'0 29.0 40.0
60'(80-) 151.0 73 1216.7 24334.3 1076.4
426.8
29.0 29.0 40.0
120' (150') 173.7 84.0 1399.2 27984.8 1250.3
490.9
29.0 29.0 40.0
200' (250') 192.9 93.4 1554.2 31083.9 1398.0
545.2
D1, D2, D3,
D4, D5, D6
35.5
35.5
41.8
206-306
Ground
42.7
0
439.6
9176.0
218.3
0.0
35.5 35.5 41.8
60'(80') 151.0 73 1554.6 32452.0 1273.3
639.6
35.5 35.5 41.8
120' (150') 173.7 84.0 1787.8 37320.3 1482.3
735.6
35.5 1 35.5 1 41.8 1
120W (250') 192.9 93.4 1985.8 41453.3 16:03.9
617.0
Note:
Calculations performed according to the information provided by the client. Cabinets were assumed solid (0% Ors iitX) for shear a 0d
tension calculation purposes. •
0000•• •
PANEL INTEGRITY SUMMARY
0000
0000
0000••
Cabinet
Roof
Height*
Horizontal
Strapping
Required
Strap WLL
(Ibs)
Chassis
Roof
Height
Horizontal
Strapping
Required
• • •
-VWVyLL
(fbsj
Al
60'(80')
No
81
60' (80')
No
• •
120'(150') No
120'(150') No
200'(250') No
200' (250') No
B2
60'(80')
No
Cl
60'(80')
No
120'(150') No
120' (150') No
200' (250') No
200'(250') No
C2
60' (80')
No
C3
60'(80')
No
120' (150') No
120'(150') No
200' (250') No -
200'(250') No
C4
60' (80')
Yes
700
C5
60'(80')
No
120'(150') Yes 700
120' (150') No
_
200' (250') Yes 700
200' (250') No-
-
Dl
60' (80')
Yes
700
D2
60' (80')
Yes
700
120' (150') Yes 700
120'(150') Yes
700
200' (250') Yes 700
200' (250') Yes
700
D3
60' (80')
Yes
700
D4
60-(80-)
Yes
700
120' (150') Yes 700
120'(150-) Yes
700
200'(250') Yes 700
200'(250') Yes
700
DS
60'(80')
Yes
700
D6
60'(80')
Yes
700
120'(150') Yes 700
120'(150') Yes
700
200' (2501) Yes 800
200' (250') Yes
800
•
• •
6666..
0000
0000••
•
0000••
•
•0000•
•••••
•0000
00.000
•
•
6000••
0
0000••
• •
ENGINEERING EXPRESS('160 SW 12'" AVE. SUITE 106 DEERFIELD BEACH, FL 33442 Page 4
(554) 354-0660 ENGINEERINGEXPRESS.COM
DAIKIN SPLIT SYSTEMS Engineering Express° TER -16-3146.2
sas
CABINETS & DIMENSIONS
Daikin Model No.
W / D (in)
H (in)
Weight
Cabinet
DX13S(A,N)0181
23
25.75
102
Al
DX13S(A,N)0241
26
27.5
103
B1
DX13S(A,N)0301
26 1
27.5
115
B1
DX13S(A,N)0361
26
27.5
118
B1
DX13S(A,N)0421
29
36.25
171
C2
DX13S(A,N)0481
29
36.25
175
C2
6X13S(A,N)0601
29
40
184
C3
DX13S(A,N)0611
35.5
38.25
211
D2
DX14S(A, N)0181
26
27.5
126
Ell
DX14S(A,N)0191
26
27.5
1:31
B1
DX14S(A,N)0241
26
27.5
126
61
DX14S(A,N)0251
26
32.5
131
B1
6X14S(A,N)0301
29
32.5
162
C1
DX14S(A,N)0311
29
32.5
162
C1
6X14S(A,N)0361
29
32.5
162
C1
DX14S(A,N)0371
29
32.5
162
C1
DX14S(A,N)0421
29
36.25
189
C2
DX14S(A,N)0431
29
36.25
189
C2
DX14S(A,N)0481
35.5
36.25
220
D1
DX14S(A,N)0601
35.5
38.25
260
D2
DX16TCO241
29
32.25
181
C1
DX16TC0361
29
38.25
184
C3
6X16TC0481
35.5
36.25
219
D1
DX16TC0601
35.5
38.25
279
D2
DX16SA0181
29
32.25
145
C1
DX16SA0241
29
32.25
142
C1
DX16SA0301
29
36.25
149
C2
DX16SA0361
29
38.25
162
C3
DX16SA0421
35.5
36.25
206
D1
DX16SA0481
35.5
36.25
219
D1
DX16SA0601
35.5
38.25
279
D2
DX16SA0611
35.5
38.25
291
D2
DX18TC0361
35.5
38.25
206
D2
DX18TC0481
35.5
38.25
268
D2
DX18TC0601
35.5 1
38.25
274
D2
Note: Illustration selected for dimensional purposes
Daikin Model No.
W / D (in)
H (in)
Weight
Cabinet:
DX20VCO241
35.5
38.25
208
D2
DX20VC0361
35.5
38.25
216
D2
DX20VC0481
35.5
41.75
1 268
D3
DX20VC0601
35.5
41.75
310
D3
DZ14S(A,N)0181
29
34.5
143
C4
DZ14S(A,N)0241
29
34.5
143
C4
DZ14S(A,N)0301
29
36.25
171
C3
DZ14S(A,N)0361
29
36.25
173
C3
DZ14S(A,N)0421
35.5
39.75
191
D5
DZ14S(A,N)0481
29
36.25
226
C3
DZ14S(A,N)0491
35.5
34.5
273
D4
DZ14S(A,N)0601
35.5
34.5
277
D4
DZ16SA0181
29
36.38
174
C3
DZ16SA0241
35.5
34.63
180
D4
DZ16SA0301
35,5
34.63
186
D4
DZ16SA0361
35.5
40
20
D6
DZ16SA0421
29
36.38
226
C3
DZ16SA0481
35.5
34.63
D4
DZ16SA0601
35.5
. 49
-,"e 6 6
Q 4
DZ16TCO241
29
61 .2
1A06.
C5 '
DZ16TC0361
35.5
•88.426
33.3
DZ16TC0481
35.5
- 66.-K
305•
DQ
DZ16TC0601
35.5
6 SS.
•309 •Di
DZ18TC0361
35.5
' Ii 25
•246' •
D6• • • 4
DZ18TC0481
35.5
29.11
•31% ;
D3.6 •'
DZ18TC0601
35.5
3 K25
ww
314
Elite 6 •
6Z20VCO241
35.5
38.25
220
D2
DZ20VC0361
35.5
41,25
•239 • •
D3
DZ20VC0481
35.5
6 41.1 .45
628y.
Cr" •
DZ20VC0601
35.5
41.25
04!� 6 •
D3
DZ14S(A,N)14019
29
34.5
143
C4
DZ14S(A,N)14025
29
34.5
143
C4
DZ14S(A,N)14031
35.5
34.63
186
D4
DZ14S(A,N)14037
35.5
40
20
D6
LIMITATIONS & CONDITIONS OF USE:
Use of this product shall be in strict accordance with this TER as noted
herein.
The supporting host structure shall be designed to resist all
superimposed loads as determined by others on a site specific basis as
may be required by the Authority Having Jurisdiction. Host structure
conditions which are not accounted for in this product's respective
anchor schedule shall be designed for on a site-specific basis by a
registered professional engineer. No evaluation is offered for the host
supporting structure by use of this document. Adjustment factors noted
herein and the applicable codes must be considered, where applicable.
All supporting components which are permanently installed shall be
protected against corrosion. contamination, and other such damage at
all times.
Fasteners must penetrate the supporting members such that the full
length of the threaded portion is embedded within the main member,
This evaluation does not offer any evaluation to meet large missile
impact debris requirements which typically are not required for this type.
of product.
ENGINEERING EXPRE.SS'�' 160 SW 12'" AVE. SUITE 106 DEERFIELD BEACH, FL 33442 Page 5
(954) 354-0660 ENGINEERINGEXPRESS.COM