FW-19-1066Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Permit No.: FW -09-19-1066 Permit Type: Fence/Wall Work Classification: Ornamental/Metal Permit status: Approved Issue Date:08/15/2019 Expiration: 02/11/2020 Location Address Parcel Number 1071 NE 95TH ST, Miami Shores, FL 33138 1132060143610 Contacts Description: 107 LF OF 5' ORNAMENTAL ALUMINUM WITH 18' Valuation: $ 4,000.00 Inspection Requests: V.TRACK ROLLING GATE 305-762-494-- Total Sq Feet: 0.00 Fees ERNESTO CAMBO Owner 1071 NE 95 ST, MIAMI SHORES, FL 33138 Home: 3053039894 SOUTHERN FENCE & DESIGN INC Contractor PAUL CASAS 7911 NW 175 ST, HIALEAH, FL 33015 ECAM@CPFINV.COM $50.00 CCF $2.40 Description: 107 LF OF 5' ORNAMENTAL ALUMINUM WITH 18' Valuation: $ 4,000.00 Inspection Requests: V.TRACK ROLLING GATE 305-762-494-- Total Sq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $2.40 DBPR Fee $2.00 DCA Fee $2.00 Education Surcharge $0.80 Planning and Zoning Review Fee $35.00 Scanning Fee $9.00 Technology Fee $3.13 Wire and Wood Fence Fee $75.00 Total: $179.33 Payments Date Paid Amt Paid Total Fees $179.33 Credit Card 05/13/2019 $50.00 Credit Card 08/15/2019 $129.33 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. re: Owner / Applicant / Agent Date August 15, 2019 Page 2 of 2 -, \� FZECEIVED Mlaml Shores Vlllage M Y 13 2019 Bullding Department BY. 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972—� INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 201 BUILDING Master Permit No. U5- PERMIT APPLICATION Sub Permit No. ZBUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLICWORKS [:]CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: j() 7 ( , I 5 -E - City: Miami Shores County: Miami Dade Zip: 3 3 ( 3R Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FIFE: OWNER: Name (Fee Simple Titleholder): Fnn eab(�a✓ nb o Phone#: 20S _WUq cf Address: 10 7 t ,eJ'C a 5 t -t; C,+ - city: •.t t t'o rr► i 6 �-?ov'+� State: F � Zip: -� � t 3 2 Tenant/Lessee Name: Phone#: —�Emal I: Wil' A _M QV dl r► J �° 01rY� CONTRACTOR: Company Name: 5p,1-f'k or v1(::! -G1 Ckon c! 0 S t c)I•r Phone#: 303 qa q OSB Address: 7a l ( City: 1enk State: Zip: Qualifier Name: 211,) ,nSG1S Phone#: Q qqc) SO'sg State Certification or Registration #: 91�(00 (3 7 Certificate of Competency #: DESIGNER: Architect/Engineer: City: n e#: State: Zip: Value of Work for this Permit: $, 4f.0000„ 19 Square/Linear Footage of Work: (= Type of Work: ❑ Addition ❑ Alteration �] New ❑ Repair/Replace ❑ Demolition Description of Work: 107 L F QC SL w 1, -t-o QP n n VW yr f- j v-+0go- roll; Specify color of color thru tile: Submittal Fee $ � • � Permit Fee $ Scanning Fee $ Technology Fee Structural Reviews $ (Revised02/24/2014) Radon Fee $ Training/Education Fee $ CCF $ DBPR $ CO/CC $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State n Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition t the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of he notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachmE rj't. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved Xd °I reinspection fee will be charged. Signature OWNER or AGENT The foregoing instrument was acknoI ledged before me this Q� I day of 20 , by ,� (�}",,,,t L72n/ t-01 29 ,who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: 7Pr,int: Cijn/iY L�2G�rY1A Seal Signature CONTRACTOR The foregoing instrument was acknowledged before me this day of r i lit n _,20 ►-1 by PM1 Lasq.i— , who is personally known to me or who has produced It Prl ye f; 1� ce,f i� as identification and who did take an oath. NOTARY PUBLIC: Seal ILIANA LEZCANO M cOMNESSION # FF919551 * APPROVED BY (Revised02/24/2014) Plans Examiner Structural Review ADRIANA C. PEREZ Notary Public - State of Florida Commission # FF980353 Zoning Clerk 4/10/2019 Property Search Application - Miami -Dade County OfFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3206-014-3610 Property Address: 1071 NE 95 ST Miami Shores, FL 33138-2547 Owner ERNESTO CAMBO ANA MARIA PRIU CAMBO Mailing Address 4255 LAKE RD MIAMI, FL 33137 USA PA Primary Zone 1400 SGL FAMILY - 3001-3250 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 4/3/0 Floors 2 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 2,806 Sq. Ft Lot Size 17,125 Sq.Ft Year Built Multiple (See Building Info.) Assessment Information Year 2018 2017 2016 Land Value $616,680 $616,680 $633,382 Building Value $198,444 $198,794 $199,144 XF Value $29,460 $29,702 $29,946 Market Value $844,584 $845,176 $862,472 Assessed Value 1 $363,398 $355,924 $348,604 Benefits Information Benefit Type 2018 2017 2016 Save Our Homes Assessment Cap Reduction $481,186 $489,252 $513,868 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 3 PB 10-37 E1/2 OF LOT 25 & LOT 26 & 27 BLK 81 LOT SIZE IRREGULAR OR 18367-769 1198 1 Generated On : 4/10/2019 Taxable Value Information 2018 2017 2016 County Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $313,398 $305,924 $298,604 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value $338,398 $330,924 $323,604 City Exemption Value 1 $50,000 $50,000 $50,000 Taxable Value 1 $313,398 $305,924 $298,604 Regional Exemption Value 1 $50,000 $50,000 $50,000 Taxable Value $313,398 $305,924 $298,604 Sales Information Previous Sale Price OR Book -Page Qualification Description 09/13/2018 $1,100,000 31143-4774 Qual by exam of deed 11/01/1998 $275,000 18367-769 Sales which are qualified 01/01/1982 $250,000 11382-0122 Other disqualified 08/01/1976 1 $81,000 00000-00000 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: Southern Fence and Design Inc. 7911 NW 1751h St Hialeah FI, 33015. 303-949-5058 Paul.casas@icloud.com Date: 5110119 State of County of .s.{ ,,.,,; aJe Before me this day personally appeared e_Q,-� who, being duly sworn, deposes and says That he or she will be the only person working on the project located at: Sworn to (or affirmed) and subscribed before me this LA-- ay of .20&_, by Paul A( a&o s Personally know / Or Produced Identification V Type of Identification Produced r nW11c s ADRIANA C. PEREZ Notary Public - State of Florida o` Commission # FF980353 My Comm. Expires Apr 7, 2020 'A&- "n' C, Print, Type or Stamp Name of Nota Notice to Owner — Workers' Com Miami shores Vffillage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 nsation Insurance Exemption Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. lila. Stat. § 440.05 allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to obtaining a building permit. Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure: An employer in the construction industry who employs one or more part-time or full-time employees, including the owner, must obtain workers" compensation coverage. Corporate officers or members of a limited liability company (LLC) in the construction industry may elect to be exempt if: 1. The officer owns at least 10 percent of the stock of the corporation, or in the case of an LLC, a statement attesting to the minimum 10 percent ownership; 2. The officer is listed as an officer of the corporation in the records of the Florida Department of. State, Division of Corporations; and 3. The corporation is registered and listed as active with the Florida Department of State, Division of Corporations. No more than three corporate officers per corporation or limited liability company members are allowed to be exempt. Construction exemptions are valid for a period of two years or until a voluntary revocation is filed or the exemption is revoked by the Division. Your contractor is requesting a permit under this workers" compensation exemption and has acknowledge that he or she will not use day labor, part-time employ r subcontractors for your project. The contractor has provided an affidavit stating that he or site will be the only person allowed t + rk on your project. In these circumstances, Miami Shores Village does not require verification of workers' compensationinsur coverage from the contractor's company for day labor, part-time employees or subcontractors. BY SIGNING BELOW Y ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS CONTENTS. X Signature: State of Florida County of Miami -Dade -14 The foregoing was acknowledge before me this s 1 day of A4A_e2_C# By C(6_�Q �Vq Jt3, 0 who is personally known to me or has produced _...... ___........_.�___.._._._ as identification. SEAL ILIANA LEZCANO MY COMMISSION # pp919S31 U L 13 i+. oppv-- SKETCH OF c" i I I q3;10 14 r .. I �es om°n I i I I I I I I I I I I I I I I I II I I I �a 17 1 `LOTI11619 I OCK 81 `i 9s I I I Pa I I I I I — — •Sar 59' m'w (c sso•�1 1/ SBB' Op' tSW N 350_ (M) ♦25(P N E 9 5 T H S i R E E i ----------- BOUNDARY SURVEY GRAPHIC SCALE t=ear ) 1 ch 20 K 57/- u ,,,1k rid' O i C;1!1�G1 7 oil v» 9h (_#ivy) a I I I I .. ... I � . . . . . . . J z • • • • • • • • • • a c � w M qm r ""' • • • — V �' sm am • • •o • `cc • s 0 0 ic�oa• .:e 5•�r • • • • m w d L ..r^ n Mq.lm em °p � vn.x:m ver E m.Unrt • • ••• O ••• • W Llj� 05 Z E5 d CC I J } �- F— � � G CL c LL w a o o LL! f z G z a - o - ._ _N I I I Pa I I I I I — — •Sar 59' m'w (c sso•�1 1/ SBB' Op' tSW N 350_ (M) ♦25(P N E 9 5 T H S i R E E i ----------- BOUNDARY SURVEY GRAPHIC SCALE t=ear ) 1 ch 20 K 57/- u ,,,1k rid' O i C;1!1�G1 7 oil v» 9h (_#ivy) a I I I I • • • • • • • • • • ••• •• • • • •• •• ••• • • • ••• • • urveyed Site t E .. _ 0�...�..a,.. I LOCATION MAP —' 0t two Scare em.... u° raE..„�nr,. m.r arm-r.w.�r.mwm.r. 29 M:�, �'..,.r..w. •r., m rr.e r .rmr,�r, rr.4 ✓✓ �t., saov. 5.e awr w nwnn r..a. ra e w .r. a..aaw rr.n�tx muuua mmlmm.�wa.nsa �. t°mw �..d maaoawn°.erm�uu�n.. r•....o °rrnwrre. wn mr m r.w.ra n w anorn... r.r...a r auy'�'�'ap....aa ey w awry mi..nr m m w a.a v a rr�MY4� wmvna TM Sw.eN �u. Po�ormMro.•uu..i. _- _ _ wWgmva kwn. a.Inib r •.uf.n �ve „ye�uuer n .memos 'moi n r�rN r u+w �.r.: q u°uce a.n°.e trove weatvwnw rm�uw r,rt wm. vm.w to.r, ue.. Ao.a. sem.ruse,r„twrw�..m.r�...rmmw�:�.,ba y:. e�.on�w'Hbos.m'e. Sea pw.eeu n w darn r .xeret anNtrof cyw 5 �. irim �M aura E w+ru�mW� �r'rs mfr a+l .err• w.m...r-m.ar.r.•r. (&, 9�/�f� es oO;wJ M Wim .. ... . . . . . . . • • • • • • • • • • • M qm r ""' • • • • • �' sm am • • •o • • • s 0 ic�oa• .:e 5•�r • • • • m w d ..r^ n Mq.lm em °p � vn.x:m ver E m.Unrt • • ••• • ••• • • • • • • • • • • • ••• •• • • • •• •• ••• • • • ••• • • urveyed Site t E .. _ 0�...�..a,.. I LOCATION MAP —' 0t two Scare em.... u° raE..„�nr,. m.r arm-r.w.�r.mwm.r. 29 M:�, �'..,.r..w. •r., m rr.e r .rmr,�r, rr.4 ✓✓ �t., saov. 5.e awr w nwnn r..a. ra e w .r. a..aaw rr.n�tx muuua mmlmm.�wa.nsa �. t°mw �..d maaoawn°.erm�uu�n.. r•....o °rrnwrre. wn mr m r.w.ra n w anorn... r.r...a r auy'�'�'ap....aa ey w awry mi..nr m m w a.a v a rr�MY4� wmvna TM Sw.eN �u. Po�ormMro.•uu..i. _- _ _ wWgmva kwn. a.Inib r •.uf.n �ve „ye�uuer n .memos 'moi n r�rN r u+w �.r.: q u°uce a.n°.e trove weatvwnw rm�uw r,rt wm. vm.w to.r, ue.. Ao.a. sem.ruse,r„twrw�..m.r�...rmmw�:�.,ba y:. e�.on�w'Hbos.m'e. Sea pw.eeu n w darn r .xeret anNtrof cyw 5 �. irim �M aura E w+ru�mW� �r'rs mfr a+l .err• w.m...r-m.ar.r.•r. (&, 9�/�f� es oO;wJ M Wim rft�i�. I-)N_X__k_ --- -� Overall Gate Length —' n 14 b' k •• ••• • • • • • •• `G q •• ••• ••i ••• • • •• • • • { • • • • • • • • • •• • • • i • • • • • • ! • • .... ....... . ESE, QED . ..... . ... MAY 21 209 . ...... . .... .... . . .... . TYPICAL ALUMINUM FENCE DETAIL Please indicate dimensions in highlighted spaces beloA••••, F-igk= SUPPORT POST SPACING """ • F-igk= dric-instNIAtton Details Scale: 374 `—'I` -Q" • • (Typical) vale veLaii5 Scale: 3/8" = 1'-0" Hardware Details (Typical - Single or Double) I L I Scale: 1" = 1'-0" ID GENERAL NOTES (Design): 1. LOCATION: This design is for AT GRADE railing installations ONLYH Installations above grade shall be designed for specific conditions for the location. 2. COMPLIANCE: Design complies with the requirements of the FBC 2017, 6th Edition & ASCE 7-10, 115 MPH (Category I, 3 second gust), Exposure C. 3. CONNECTION METHODS: Fencing panels (Pickets & Rails) may be either mechanically (screw) connected using #12 1-1/4" Tek screws or tack welded. Gate frames shall be fully welded by a certified welder in the shop using 5183 or 4043 filler metal with 1/4" weld all around. 4. GATES: Gate leaf (single or double) widths can be installed up to the allowable size as shown in Gate Details. Should a double leaf gate be installed then the Latch and Drop Bolt shall be installed (per the local requirements). 5. SOIL: All soil around footings shall be 98% optimum density (2,500 psf minimum capacity). 6. OPENINGS & ENDS: All openings shall be able to reject a 4" sphere. All exposed visible ends shall be provided with caps or covers. 7. THREE RAIL STYLE: May allow for opening between top and intermediate horizontal rail or be filled with pickets and optional decorative rings or scrolls without affecting engineering design. GENERAL NOTES (Installation): 1. POST CONNECTIONS: a. POST @ CONCRETE DECK PLATE / SHOE: Pre -manufactured Aluminum post shoe or 4"W0/16" aluminum plate anchored with (4) 1/4"0 x 3-1/2" tapcons (minimum 3" embed). Attach shoe to post using (2) #14 x 3/4" SMS. b. POST @ CONCRETE DECK CORE DRILL: Core concrete deck 3"0 x 3-1/2" and install post with high strength epoxy grout (10,000 psi minimum). c. POST @ GRADE: Anchored in 10" x 24" (2,500 psi) concrete. 2. WALL CLIP CONNECTION: (Pre -Manufactured or 2"x2"x1/8" aluminum bent plate) Aluminum to concrete connections shall be 1/4"0 x 2-1/4" tapcons (min. 1-3/4" embed). Aluminum to aluminum connections shall be made using (2) #8 x 1" Tek screws per receiver. 3. RAIL / POST CONNECTION: (1) # 8 x 1" Tek screws or fully welded. 4. RAIL / PICKET CONNECTION: (1) # 8 x 1" Tek screw or fully welded. 5. PLEXIGLASS PANEL / FRAME, POST, PICKET: Affix at centerline of latch to Post, Frame & Pickets #12 Tek @ 8"o.c. GENERAL NOTES (Materials): 1. All aluminum extrusions shall be made of alloy 6063-T6 Alloy (35,000 psi yield) unless noted otherwise. All fence panels and gates shall be powder coated or factory finished for corrosion resistance. Aluminum shall NOT be in direct contact with concrete. 2. POOL FENCING ENCLOSURES: 2.1. All gates shall open outward and shall be 48" high and have no opening more than 1/2" within 18" of the latch. 2.2. All hardware used shall be automatically, self-closing and self -latching. Magna Latch and Lokk bolt shall be used in a pool fencing application with latch location 54" AFF minimum. See Component Items / Manufacturers List Item: D&D Technologies Part # Hinges: True Close TCA1 WTL2-Mk2 Latches: Lokk Latch MGHDD1019 Magna Latch MLTPS2BGA Drop Rods: 24" Metal Drop Bolt NW38305N-24SSW 24" Lokk Bolt MGHDR1061 WT Drawing # component 5cneauie and u DESCRIPTION SIZE Adjustable self-closing REMARKSCN BR Bottom Rail hinge attached with HR -3 or HR12 Pickets may punch through or stop @D rail CF #12 x 3/4" Tek screws HI o m per manufacturer Core Drill a- ° ° CD requirements Hinge Detail g Drop Rod 318"0 x 24" Magna Standard Drop Bolt G F Gate frame Latch 19-63-209 All corners fully welded H I Automatic latch NIA NIA Standard 4" Self -Closing Hinges with #12 x 3/4" Horizontal Rail 1" x 2" x 0.062" HR -3 or HR12 Tek screws LA ofo per manufacturer o Pickets may punch through or stop @rail D CD requirements (D a Latch Detail Coordinate with Local Fire Department LA NOTE: NIA NIA Standard Self -Locking Latch Orily One Drop DR 2" x 2" x 0.066" HR -4 Rod is Required !!! G P Gate Post 2" x 2" x 0.125" 19-63-209 - PI Picket 3/3"0 center drop HR -5 Alternate: HR -13 (314" x 314" x 0.040") cM rod & guide 18" x 18" x 0.25" NIA 0 o with (4) #12 Tek Top Rail 1.6" x 2.6" x 0.06" 0 o sci,ews Drop Rod Detail Wall Clip 1-318"x 1-114" 21-00-186 Alternate: 21-00-185 LLJ Hardware Details (Typical - Single or Double) I L I Scale: 1" = 1'-0" ID GENERAL NOTES (Design): 1. LOCATION: This design is for AT GRADE railing installations ONLYH Installations above grade shall be designed for specific conditions for the location. 2. COMPLIANCE: Design complies with the requirements of the FBC 2017, 6th Edition & ASCE 7-10, 115 MPH (Category I, 3 second gust), Exposure C. 3. CONNECTION METHODS: Fencing panels (Pickets & Rails) may be either mechanically (screw) connected using #12 1-1/4" Tek screws or tack welded. Gate frames shall be fully welded by a certified welder in the shop using 5183 or 4043 filler metal with 1/4" weld all around. 4. GATES: Gate leaf (single or double) widths can be installed up to the allowable size as shown in Gate Details. Should a double leaf gate be installed then the Latch and Drop Bolt shall be installed (per the local requirements). 5. SOIL: All soil around footings shall be 98% optimum density (2,500 psf minimum capacity). 6. OPENINGS & ENDS: All openings shall be able to reject a 4" sphere. All exposed visible ends shall be provided with caps or covers. 7. THREE RAIL STYLE: May allow for opening between top and intermediate horizontal rail or be filled with pickets and optional decorative rings or scrolls without affecting engineering design. GENERAL NOTES (Installation): 1. POST CONNECTIONS: a. POST @ CONCRETE DECK PLATE / SHOE: Pre -manufactured Aluminum post shoe or 4"W0/16" aluminum plate anchored with (4) 1/4"0 x 3-1/2" tapcons (minimum 3" embed). Attach shoe to post using (2) #14 x 3/4" SMS. b. POST @ CONCRETE DECK CORE DRILL: Core concrete deck 3"0 x 3-1/2" and install post with high strength epoxy grout (10,000 psi minimum). c. POST @ GRADE: Anchored in 10" x 24" (2,500 psi) concrete. 2. WALL CLIP CONNECTION: (Pre -Manufactured or 2"x2"x1/8" aluminum bent plate) Aluminum to concrete connections shall be 1/4"0 x 2-1/4" tapcons (min. 1-3/4" embed). Aluminum to aluminum connections shall be made using (2) #8 x 1" Tek screws per receiver. 3. RAIL / POST CONNECTION: (1) # 8 x 1" Tek screws or fully welded. 4. RAIL / PICKET CONNECTION: (1) # 8 x 1" Tek screw or fully welded. 5. PLEXIGLASS PANEL / FRAME, POST, PICKET: Affix at centerline of latch to Post, Frame & Pickets #12 Tek @ 8"o.c. GENERAL NOTES (Materials): 1. All aluminum extrusions shall be made of alloy 6063-T6 Alloy (35,000 psi yield) unless noted otherwise. All fence panels and gates shall be powder coated or factory finished for corrosion resistance. Aluminum shall NOT be in direct contact with concrete. 2. POOL FENCING ENCLOSURES: 2.1. All gates shall open outward and shall be 48" high and have no opening more than 1/2" within 18" of the latch. 2.2. All hardware used shall be automatically, self-closing and self -latching. Magna Latch and Lokk bolt shall be used in a pool fencing application with latch location 54" AFF minimum. See Component Items / Manufacturers List Item: D&D Technologies Part # Hinges: True Close TCA1 WTL2-Mk2 Latches: Lokk Latch MGHDD1019 Magna Latch MLTPS2BGA Drop Rods: 24" Metal Drop Bolt NW38305N-24SSW 24" Lokk Bolt MGHDR1061 WT Drawing # component 5cneauie and u DESCRIPTION SIZE EMS # REMARKSCN BR Bottom Rail 1" x 2" x 0.062" HR -3 or HR12 Pickets may punch through or stop @D rail CF Concrete Footing See Schedule NIA 3,000 psi (Minimum) CD Core Drill 3"0 x 3-112" NIA 10ksi, fill epoxy or high strength grout DR Drop Rod 318"0 x 24" NIA Standard Drop Bolt G F Gate frame 2" x 2" x 0.125" 19-63-209 All corners fully welded H I Hinge NIA NIA Standard 4" Self -Closing Hinges H R Horizontal Rail 1" x 2" x 0.062" HR -3 or HR12 Pickets may punch through or stop @rail I R Intermediate Rail 1" x 2" x 0.062" HR -3 or HR12 Pickets may punch through or stop @rail KB Knox Box TBD NIA Coordinate with Local Fire Department LA Latch NIA NIA Standard Self -Locking Latch LP Line Post 2" x 2" x 0.066" HR -4 with HR -2 Snap plate or solid post G P Gate Post 2" x 2" x 0.125" 19-63-209 - PI Picket 1" x 1" x 0.044" HR -5 Alternate: HR -13 (314" x 314" x 0.040") P P Plexiglass Panel 18" x 18" x 0.25" NIA Use where required TR Top Rail 1.6" x 2.6" x 0.06" HR -1 Alternate: HR -10 812 (1.2" x 2.5" x 0.06") WC Wall Clip 1-318"x 1-114" 21-00-186 Alternate: 21-00-185 (Typical) Scale: Not to Scale enerai Notes (Typical) 0 0� ^moo 'O 20 � Q N LO�Q V 0 �I oM r. �o� �. Q o 6 p O :�E o U T O V N lV T � o U a t>3 a +r L i a z 3 w o 0 a C 3 o M o En 3 +T C `o -U o � 3 a� � N ai d a� Cn c Q O in U H a a d (n v U � � a � C;) a Q U_ m 0 A1.0