WS-19-2057Location Address
Perm .:WS -09 19 2057
Miami Shores Village Permit Tw, 1Afindows/Sht rs
10050 NE 2 Ave +
Miami Shores FL 33138ork�Classif3cation: Window/moor Replacement
305-795-2204 Permit Status: Approved
Issue Date: 09/17/2019 Expiration: 03/16/2020
Parcel Number
350 NE 107TH ST, Miami Shores, FL 33138 1122310130330
:ontacts
WOLFGANGE HERZ Owner FHIA LLC Contractor
350 NE 107 ST, MIAMI SHORES, FL 331617106 WAYNE BURNETT
Business: 9547924415210 PERMITS@FHAPRODUCTS.COM
Description: REPLACING 8 WINDOWS & 1 DOOR Valuation: Inspection Requests:
p $ 36,881.00
X05-762-494
Total Sq Feet: 0.00
Fees
Amount
Application Fee - Other
$50.00
CCF
$22.20
DBPR Fee
$2.85
DCA Fee
$2.00
Education Surcharge
$7.40
Scanning Fee
$9.00
Technology Fee
$4.75
Windows/Shutters Fee
$140.00
Tota I :
$238.20
Building Department Copy
In consideration of the issuance to me of this e
pertaining thereto and in strict conformity wit t
Village. In accepting this permit I assumer spdi
permits are required for ELECTRICAL, PLUIEtlli
1i I, `!
OWNERS AFFIDAVIT: I certify that all_ihe-for
regulating construction and zoning. uther;
Payments
Date Paid Amt Paid
Total Fees
$238.20
Credit Card
09/04/2019 $50.00
Credit Card
09/17/2019 $188.20
Amount Due:
$0.00
dt, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
5ity for all work done by either myself, my agent, servants, or employes. I understand that separate
MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
omg information is accurate and that all work will be done in compliance with all applicable laws
e e above named contractor to do the work stated.
Authorized Signature: Owner / Applicant / Contractor / Agent
Date
September 17, 2019 Page 2 of 2
BUILDING
PERMIT APPLICATION
���a�jED
Miami Shores Village EP 42d19
Building Department
BY
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
j BUILDING ❑ ELECTRIC ❑ ROOFING
❑PLUMBING ❑ MECHANICAL ❑PUBLICWORKS
FBC 20
Master Permit No. �— b I q 1`71
- —zoS
Sub Permit No.
❑ REVISION ❑ EXTENSION ❑RENEWAL
❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS:, N [C) 5
City: Miami Shores County: Miami Dade Zip: 3 r
Folio/Parcel#: 1 - u__� i - 6 ► 3 p C�) Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): (APhone#:.-7 Z(c,-3c)2—C/q 5 S
Address: -2 NJ�E 1O__� 5�-
City: k_Al CA Slr,n"_ J State: L Zip: SP,
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR: Company Name: fi �A ! 4-\ Phone#: Cl S2i - :) `i Z-11 Ll\ S
Address: 3,0 4�-( Sw 4 Z,nc` S
City: �� .� G. c�� G'c1 State: L Zip: 3 3 i
Qualifier Name: �a k i `[y\_.Q l 17�U��P Phone#:
State Certification or Registration #: Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address: City: State:
Value of Work for this Permit: $ (a , 7 t Square/Linear Footage of Work:
Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace
Description of Work:
Specify color of color t ru tile:
Submittal Fee $ SO Permit Fee $
Scanning Fee $
Radon Fee $
Technology Fee $ Training/Education Fee $
Structural Reviews $
(Revised02/24/2014)
Zip:
❑ Demolition
CCF $ CO/CC $
DBPR $ Notary $
Double Fee $
Bond $
TOTAL FEE NOW DUE $ 1&&,, 2-0
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded tic of co mencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permi i is d. the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged. p, I \
Signature
OW R or AGENT
The foregoing instrument was acknowledged before me this
day\ of
yS � 201, by
whois personally kn n to
me or who has produced as
identification and who did take an oath.
NOTARY
Sign:
ZAf �G�lt7
Prin
Seal:
':a�•.,
ABDIELR.CASTILLO
r =
MY COMMISSION # GG 019600
a
EXPIRES: March 6, 2021
• JF OF
APPROVED BY
(Revised02/24/2014)
Signatu
CONTRACTOR
The foregoing instrument was acknowledged before me this
day of ori 20 by
10' who is a wn to
me or who has produced as
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
�"'•' MIGUEL A MERCADO
Print: I�`"k•:
EXPIRES April 19, 2021
*********************************************************
Plans Examiner
Structural Review
Zoning
Clerk
Property Search Application - Miami -Dade County Page 1 of 1
OFFICE OF
HE PROPERTY
APPRAISER
Summary Report
Property Information
Folio:
11-2231-013-0330
Property Address:
350 NE 107 ST
Miami Shores, FL 33138-7106
Owner
WOLFGANG HERZ
Mailing Address
350 NE 107 ST
MIAMI SHORES, FL 33161-7106
PA Primary Zone
1000 SGL FAMILY - 2101-2300 SQ
Primary Land Use
0101 RESIDENTIAL -SINGLE
FAMILY: 1 UNIT
Beds / Baths / Half
2/2/0
Floors
1
Living Units
1
Actual Area
2,150 Sq.Ft
Living Area
1,293 Sq.Ft
Adjusted Area
1,725 Sq.Ft
Lot Size
14,375 Sq.Ft
Year Built
1947
Assessment Information
Year
2019
2018
2017
Land Value
$339,308
$323,150
$359,950
Building Value
$120,060
$120,060
$120,060
XF Value
$29,402
$29,482A$322,855
Cap
Market Value
$488,770
$472,692
Exemption Value $50,000 $50,000
Assessed Value
$335,897
$329,634
$25,000
Benefits Information
Benefit
Type
2019
2018
2017
Save Our Homes
Assessment
Taxable Value 1 $285,8971 $279,6341
$272,855
School Board
Exemption Value
$25,000
$152,873
$143,058
$186,717
Cap
Reduction
$297,855
City
Exemption Value $50,000 $50,000
Homestead
Exemption
$25,000
$25,000
$25,000
Second
Taxable Value $285,8971
$279,6341 $272,855
07/01/2001
$216,500
Exemption
$25,000
$25,000
$25,000
Homestead
18650-
Sales which are disqualified as a result
Note: Not all benefits are applicable to all Taxable Values (i.e. County,
School Board, City, Regional).
Short Legal Description
31 52 42 PB 6-82
FIRST ADD TO PASADENA PARK
LOT 8&9BLK12
LOT SIZE 115.000 X 125
OR 19833-2281 07 2001 1
Generated On : 8/21/2019
Taxable Value Information
Previous
2019
2018
2017
County
Exemption Value $50,000 $50,000
$50,000
Taxable Value 1 $285,8971 $279,6341
$272,855
School Board
Exemption Value
$25,000
$25,000
$25,000
Taxable Value
$310,897
$304,634
$297,855
City
Exemption Value $50,000 $50,000
$50,000
Taxable Value $285,897 $279,634
$272,855
Regional
Exemption Value $50,000
$50,000 $50,000
Taxable Value $285,8971
$279,6341 $272,855
Sales Information
Previous
OR Book -
Price
Description
Sale
PageQualification
22065-
02/01/2004
$410,000
Sales which are qualified
1539
19833-
07/01/2001
$216,500
Sales which are qualified
2281
18650-
Sales which are disqualified as a result
12/01/1998
$0
3985
of examination of the deed
14558-
05/01/1990
$100,000
Sales which are qualified
2611
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
https://www8.miamidade.gov/Apps/PA/propertysearch/ 8/21/2019
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756,8972
Inspection requirements for.
Windows, Doors. Skylights or Fixed Glass (cladding) Permits
Upon issuance of permits for the scope of work involving the removal, changing and/or
replacement of any type of windows, doors, sidelites, skylights or fixed glass (cladding)
the permit holder or qualifier bearing his signature on the permit application shall abide
by the requirements of this department and comply with the following statement:
Upon obtaining window and/or door permits for the installation of same, it is the
responsibility of the permit holder to request window/door framing in -progress
inspection, prior to concealment of any horizontal or vertical clip mullion, bucks, shims,
etc. Inspector will also verify anchor type, edge distance, embedment and spacing. The
purpose for this inspection, is for the verification of conformance with Product
Approval (NOA).
Acknowledgement:
Date Print Name
%towardToE 9S4,7924415
Miami Dade 305 595990
Fa, 959,192-7170
Wet wtiww fhap ndairts form
(malt InfnaaRtaprodtrtts rom
Home trt1prot-re7mGe�nt [ontracr
®,�f"C ter! .. F� ! ,_, Home Ph; LII v
�) Alt
{mOwW ei _-- •,� Email'
ares i1w2le—L'�L _ a:?I G►
:.udieas Crty County state 7ik
J I,., i ontract is mane ane entered Into this �y d,iy of - ztz/ -__. rq/-ty and brtween fflorid r Home improvement Associates, Inc, a
tionda Corporation known as ('Contractor' or vFHIA`), and Owittfi'{s) named above of the property located at the address listed above known as
i"Owner , 'the Contractor agrees to perform the work described below at the property listed above obsol— .wvaem®mam.
Remove .'x"nng unas to be replaced (Nnte: Ferrio—c ,terns are fikaiv it he Aamaartl.) saar6x+. aw
Prepare odenetg i KP»any to receive replacement unds
-'1 vvmdow, nvl Energy Storm saver aluminum innulatrd _ Aluminum Non-insulatetl as �m°°v
.ie.aa®a
51 Door, Z,! I neriry Storm SW1 Mummum m triatrcl _. Aluminum Non.lnsuiatro
Glass:y/,v 4WA (t}wnPact 4 B Non•Impact I Frame Color: Pf hite: _ Rronae: _ 8/ihf __ Tan: _,_ Grey: _ Mill:
GrWs Double Hune �1ti $j® Hurl! Cisement •_--v---__--•--+ �"�
j Yes ( ) No {) �Qttl•_ OtY —_ OtY Qilr:_ tat,; APA
i Standar•�"'"
B —�� i/9-1/2 i/a
Custom Active 9 Fixed AF LH RM
"
1/3.1/3.1/3
I Sliding ss Door Sinal, French Doubk French Getametrk QrY:._
AA F F FAAF tenor Qty: _ Doors: Otv:
Qt,
:_ I IRH { ) TAI { ) RA ( ) to { )
L S. lvoa to be compirted as stated on the accompanying worksheet Work NOT to be complitied 61h,r '
---- - _ Initial Herr:
6, it ppl cable remcv-cot`'---r- s der �/aJls� and/ _ _ Initial re:
diel mtru[ti^ns/LJ1C Q✓-_1=1��r�:�:!-_L.sZtG�-.F�1. .I a•'Yt.'-''�of •`p�,
-•_6�2u..,.. rt,. .._--
Cleanup job oe6ns and provide necessary permits and m r. re. d applicable, in Me event that Con r orfs unable for whatever reason to obtain proper
oermds pilot to commencement of any work. Contractor shall refund any previous payment a his transaction shay be automatkally cancelled
>uddibhar wmke?rlo hr,nn w i er th2w,ngf*naI mstalw s to bddone u oted b -
�.6'
a_arrancy Contrectu• w -It provide warranty information er within 30 daysl h r completion and fine payments
Y_hetiulr nntraaor shad rommence the wgik within ays after execution of the Contract Rhe "Commencement Date) and shall endeavor
to tnmolete 311 work he+eunder within 'i/ days after the Commencement Date
,e ect,ng me +rciance option tot the partial or full payment of this project The Owner agrees to sign all finance completion forms the final day
.�' :rsta.iauori Tne scnFduucg and completion of the final inspection will be scheduled for the next available day and 6U checklist Items, parts,
•eplacement or damaged p•oduct reorders will be completed in a timely manner as part of our service policy Initial Here
Notice to the owner, H financing a being obtained by owner,
a) Do not sign this Contract or any financing document In blank. You are entitled to a copy of the contract at the time You 2130
b) The financial documents provided by the lender to this home improvement contract may create a lien on your property
c) Be sure you understand all provisions of the Contract and financial documents before you sign
t OrALPRICQ 5 ... OLtsDepositto Order, 5
sales tan Payment uay Job Starts. S
total Project 5-� :.iiAL 00 tnstaliation Completion $ � r
Mnr�llaneou Tta (01,Uact Win file accompanying worksheet contain the entire agreement netween the parties By signing this Contract, Owner
aerr-F sand arkrnwiedges that a Las received the accompanying worksheet. This Contract may not be changed orally but only by a Change Order or
r^er yr •tten amennrc"_t stencil by h.rth parties_ The waiver by any party of a breach of any provisions of this Contract shall not operate or be
,p^owed as d waiver or any wntten amendment or waiver of any subsequent breach by any party You the buyer may cancel this Contract at any
time prior to midnight on the third business day after the date of this Contract-
wrtne;s wnrrrpf. the dad
partles hereto have read, understand and agree to nosh sides of this Contrart. Se me a explicado el contras le totes
,- rnoendo tocia, �as-o^dinonek de este contrato. Both parties execute this Contract and the owner(s) agree to II balance e u d!r his
:onract : ndei •rd• as of the day and year first above written. /
t --
Owner Print/ --71 r +� Co-owner Print Contra�Re/
pre, _' e�Vve Prin
L
----- — Co-owner Signature ContraceRePresaUve $%nta'
tu-r'e
OwnV Signature �
I
Phone
ROME OdtfNER ASSOCII Name' e
!ij 1 i NO ( Property Name.._ -- — ---
n
Scanned with CamScanner
Florida Home Improvement Associates
Ekence No. CGC 061890 /QU418
F101i10
HOME
Ik�JspOFMFNT
Job. ---1l -
ASSOCIATES .•_
%towardToE 9S4,7924415
Miami Dade 305 595990
Fa, 959,192-7170
Wet wtiww fhap ndairts form
(malt InfnaaRtaprodtrtts rom
Home trt1prot-re7mGe�nt [ontracr
®,�f"C ter! .. F� ! ,_, Home Ph; LII v
�) Alt
{mOwW ei _-- •,� Email'
ares i1w2le—L'�L _ a:?I G►
:.udieas Crty County state 7ik
J I,., i ontract is mane ane entered Into this �y d,iy of - ztz/ -__. rq/-ty and brtween fflorid r Home improvement Associates, Inc, a
tionda Corporation known as ('Contractor' or vFHIA`), and Owittfi'{s) named above of the property located at the address listed above known as
i"Owner , 'the Contractor agrees to perform the work described below at the property listed above obsol— .wvaem®mam.
Remove .'x"nng unas to be replaced (Nnte: Ferrio—c ,terns are fikaiv it he Aamaartl.) saar6x+. aw
Prepare odenetg i KP»any to receive replacement unds
-'1 vvmdow, nvl Energy Storm saver aluminum innulatrd _ Aluminum Non-insulatetl as �m°°v
.ie.aa®a
51 Door, Z,! I neriry Storm SW1 Mummum m triatrcl _. Aluminum Non.lnsuiatro
Glass:y/,v 4WA (t}wnPact 4 B Non•Impact I Frame Color: Pf hite: _ Rronae: _ 8/ihf __ Tan: _,_ Grey: _ Mill:
GrWs Double Hune �1ti $j® Hurl! Cisement •_--v---__--•--+ �"�
j Yes ( ) No {) �Qttl•_ OtY —_ OtY Qilr:_ tat,; APA
i Standar•�"'"
B —�� i/9-1/2 i/a
Custom Active 9 Fixed AF LH RM
"
1/3.1/3.1/3
I Sliding ss Door Sinal, French Doubk French Getametrk QrY:._
AA F F FAAF tenor Qty: _ Doors: Otv:
Qt,
:_ I IRH { ) TAI { ) RA ( ) to { )
L S. lvoa to be compirted as stated on the accompanying worksheet Work NOT to be complitied 61h,r '
---- - _ Initial Herr:
6, it ppl cable remcv-cot`'---r- s der �/aJls� and/ _ _ Initial re:
diel mtru[ti^ns/LJ1C Q✓-_1=1��r�:�:!-_L.sZtG�-.F�1. .I a•'Yt.'-''�of •`p�,
-•_6�2u..,.. rt,. .._--
Cleanup job oe6ns and provide necessary permits and m r. re. d applicable, in Me event that Con r orfs unable for whatever reason to obtain proper
oermds pilot to commencement of any work. Contractor shall refund any previous payment a his transaction shay be automatkally cancelled
>uddibhar wmke?rlo hr,nn w i er th2w,ngf*naI mstalw s to bddone u oted b -
�.6'
a_arrancy Contrectu• w -It provide warranty information er within 30 daysl h r completion and fine payments
Y_hetiulr nntraaor shad rommence the wgik within ays after execution of the Contract Rhe "Commencement Date) and shall endeavor
to tnmolete 311 work he+eunder within 'i/ days after the Commencement Date
,e ect,ng me +rciance option tot the partial or full payment of this project The Owner agrees to sign all finance completion forms the final day
.�' :rsta.iauori Tne scnFduucg and completion of the final inspection will be scheduled for the next available day and 6U checklist Items, parts,
•eplacement or damaged p•oduct reorders will be completed in a timely manner as part of our service policy Initial Here
Notice to the owner, H financing a being obtained by owner,
a) Do not sign this Contract or any financing document In blank. You are entitled to a copy of the contract at the time You 2130
b) The financial documents provided by the lender to this home improvement contract may create a lien on your property
c) Be sure you understand all provisions of the Contract and financial documents before you sign
t OrALPRICQ 5 ... OLtsDepositto Order, 5
sales tan Payment uay Job Starts. S
total Project 5-� :.iiAL 00 tnstaliation Completion $ � r
Mnr�llaneou Tta (01,Uact Win file accompanying worksheet contain the entire agreement netween the parties By signing this Contract, Owner
aerr-F sand arkrnwiedges that a Las received the accompanying worksheet. This Contract may not be changed orally but only by a Change Order or
r^er yr •tten amennrc"_t stencil by h.rth parties_ The waiver by any party of a breach of any provisions of this Contract shall not operate or be
,p^owed as d waiver or any wntten amendment or waiver of any subsequent breach by any party You the buyer may cancel this Contract at any
time prior to midnight on the third business day after the date of this Contract-
wrtne;s wnrrrpf. the dad
partles hereto have read, understand and agree to nosh sides of this Contrart. Se me a explicado el contras le totes
,- rnoendo tocia, �as-o^dinonek de este contrato. Both parties execute this Contract and the owner(s) agree to II balance e u d!r his
:onract : ndei •rd• as of the day and year first above written. /
t --
Owner Print/ --71 r +� Co-owner Print Contra�Re/
pre, _' e�Vve Prin
L
----- — Co-owner Signature ContraceRePresaUve $%nta'
tu-r'e
OwnV Signature �
I
Phone
ROME OdtfNER ASSOCII Name' e
!ij 1 i NO ( Property Name.._ -- — ---
n
Scanned with CamScanner
Armofwm nett
Mrd f
Ana .1-ronont
150 sf
%--
C1j
Ana ofwm nmt
250 sf
L4)l. 14)
Arm ofwm mt
in
35.0 sf
Arca ofwm neat
40.0 sf
Specia8y Eng neenng Consultants Inc
Ana ofwm nett
50.0 sf
Wind Velocites in South Florida
1599 SW 30 Avenue, Suite #20 `s Dadc Broward Palm Bnch
�
ei t Zone 4 Zone 5
Boynton Beach, 334326 � Risk Cat. I 165 156 156
Zone 4 Zone 5
A Ww risk to humans farms, shads
FL CA # 009217
Jay Risk Cat. 2 175 170 170 Sin le Fano Rcsidrnccs
Zone 4 Zone 5
Risk Cat. 3&4 186 180 18U Essential Facilities
1
P - q h �p - GCp i)
Intstuclions and limitations of Usa
Zone 4 Zone 5
i Charts provide wind pressures based on the mean roof height. And shall not exceed 60'-0".
Of 40.1 40.1
15 -43.4 .6
2 Des" npressures are for an enclosed builindi shu,%n or other im ct resistance Protection required .
V (mph) 175 1620 FBC for HVHZ, or Fig. 26.5-1a
3 User shall determine the mean roof h ht, Eave he' M +Roof Peak 2.
Risk Category 11 Table l 5-1, page 2
4 End zone distance is the lessor of 10% of length, 10% of width, or 40% of the mean roof he" M and net less than 3'-0"
Exposure C tion
Se 26.7
5 If 50% of a component is in a particular zone then that component is considered to be in zone with the ma nt of the area. If eluesbonable then lace in Zone 5
Kd 11.85 Table 26.6-1, page 250
6 Each component, wirxlow, door, mullion has a tribute area that is area to be used. Arae of components to rounded down but shell not be less than 10 sf.
KAI Figure 26A-1, page 252
7 For NOA's that require a Kd=1.0 then mu8i 1 the values listed herein b 1.18.
GCpi 0.18 -U.18 0.55
BWaable stress des n.
pikhofruof 3112 14 U degrees
9 ein are valid for Ex sures B and C and sure D. max roof height 59'
theta 14A dog eeS
10 Charts and values luted herein are only valid when sinned. dated. and sealed by Gaty Mcl7ounle PF CS691 or Mnrk I nRmn, PF x-uaaa
Armofwm nett
Mrd f
Ana .1-ronont
150 sf
Arra ol coropormt
20.0 sf
Ana ofwm nmt
250 sf
Arsaofcom mt
30.0 sf
Arm ofwm mt
in
35.0 sf
Arca ofwm neat
40.0 sf
Arm ofwm neat
45.0 sf
Ana ofwm nett
50.0 sf
Arra ofwm wm
snt Arm ofnml
55.0 sf 60.0 sf
ei t Zone 4 Zone 5
Zone 4 Zone 5
Zone 4 Zone 5
Zone 4 Zone 5
Zone 4 Zone 5
Zone 4 Zone 5
Zone 4 Zone 5
Zone 4 Zone 5
Zone 4 Zone 5
Zone 4 Zone 5 Zone 4 Zone 5
Of 40.1 40.1
15 -43.4 .6
38.8
-42.2
38.8
-51.3
38.4
-41.8
38.4
-50.6
37.9
-41.4
37.9
-09.8
37..5
-41.0
37.5
-49.0
37.1
-40.6
37.1
-48.3
36.7
-40.2
36.7
-47.5
36.2
-39.8
36.2
-46.8
35.8
-39.4
35.8
-46.0
35.4 35.4 35.0 35.0
-39.0 -45.2 -38.6 -44.5
1.6 41.6
18 -45.1 -55.7
40.3
-43.9
40.3
-53.3
39.9
-43.5
39.9
-52.6
39.4
-43.0
39.4
-51.8
39.0
-42.6
39.0
-51.0
38.5
-42.2
38.5
-50.2
38.1
-41.8
38.137.7
-49.4
-41.3
37.7
-48.6
37.2
-40.9
37.2
-47.8
36.8 36.8 36.3 36.3
-40.5 47.0 -40.1 -46.2
43.0 43.0
21 -46.6 -57.6
41.6
-45.3
41.6
-55.1
41.241.2
44.9
-54.3
40.7
-44.4
40.7
-53.5
40.3
-44.0
40.3
-52.6
39.8
-43.6
39.8
-51.8
39.3
-43.1
39.3
-51.0
38.9
-42.7
38.9
-50.2
38.4
42.3
38.4
-49.4
38.0 38.0 37.5 37.5
-41.8 -48.5 -41.4 -47.7
44.2 44.2
24 -48.0 -59.2
42.8
-46.6
42.8
-56.7
42.3
-46.2
42.3
-55.8
41.9
-05.7
41.9
-55.0
41.4
-45.3
41.4
-54.1
40.9
-44.8
40.9
-53.3
40.5
-44.4
40.5
-52.5
40.0
-43.9
40.0
-51.6
39.5
-43.5
39.5
-50.8
39.1 39.1 38.6 38.6
-43.0 -49.9 -42.6 -49.1
45.3 45.3
27 -49.2 -60.7
43.9
-47.8
43.9
-58.1
43.4
-47.3
43.4
-57.2
42.9
-46.9
42.9
-56.4
42.4
-46.4
42.4
-55.5
42.0
-45.9
42.0
-54.6
41.5
-45.5
41.5
-53.8
41.0
-45.0
41.0
-52.9
40.5
-44.6
40.5
-52.0
40.0 40.0 39.6 39.6
-44.1 -51.2 -43.6 -50.3
46.3 46.3
30 -50.3 -62.1
44.9
-48.9
44.9
-59.4
44.4
-48.4
44.4
-58.5
43.9
-47.9
43.9
-57.6
43.4
-47.4
43.4
-56.8
42.9
-47.0
42.9
-55.9
42.4
-46.5
42.4
-55.0
41.9
-46.0
41.9
-54.1
41.4
-45.6
41.4
-53.2
40.9 40.9 40.5 40.5
-45.1 -52.3 -44.6 -51.4
47.3 47.3
33 -51.3 -63.3
45.8
-49.8
45.8
-60.6
45.3
-49.4
45.3
-59.7
44.8
-48.9
44.8
-58.8
44.3
-48.4
44.3
-57.9
43.8
-47.9
43.8
-57.0
43.3
-47.4
43.3
-56.1
42.8
-47.0
42.8
-55.2
42.3
-46.5
42.3
-54.3
41.8 41.8 41.3 41.3
-46.0 -53.4 -45.5 -52.5
48.2 48.2
36 -52.2 -64.5
46.6
-50.8
46.6
-61.7
46.1
-50.3
46.1
-60.8
45.6
-49.8
4.5.6
-59.9
45.1
49.3
45.1
-59.0
44.6
-48.6
44.6
-58.1
44.1
-48.3
44.1
-57.1
43.6
-47.8
43.6
-56.2
43.1
-47.3
43.1
-55.3
42.5 42.5 42.0 42.0
-46.9 -54.4 -46.4 -53.5
49.0 49.0
39 -53.1 -65.6
47.4
-51.6
47.4
-62.8
46.9
-51.1
46.9
1 -61.8
46.4
-50.6
46.4
-60.9
45.9
-50.1
45.9
-60.0
45.3
-49.6
45.3
-59.0
44.8
-49.1
44.81
-58.1
44.344.3
-48.6
-57.2
43.8
-48.1
43.8
-56.2
43.3 43.3 42.7 42.7
-47.6 -55.3 -47.1 -54.4
49.7 49.7
42 -54.0 -66.6
48.2
-52.4
48.2
-63.8
47.6
-51.9
47.6
-62.8
47.1
-51.4
47.1
-61.9
46.6
-50.9
46.6
-60.9
46.1
-50.4
46.1
-60.0
45.5
-49.9
45.5
-59.0
45.0
1 -49.4
45.0
-58.1
44.5
-48.9
44.5
-57.1
43.9 43.9 43.4 43.4
-48.4 -56.2 -47.9 -55.2
50.5 50.5
45 -54.8 -67.6
48.9
-53.2
48.9
-64.7
48.3
-52.7
48.3
-63.7
47.8
-52.2
47.8
-62.8
47.3
-51.7
47.3
-61.8
46.7
-51.2
46.7
-60.8
46.2
-50.6
46.2
-59.9
45.7
-50.1
45.7
-58.9
45.1
-49.6
45.1
-58.0
44.6 44.6 44.1 44.1
-49.1 -57.0 -48.6 -56.0
51.2 51.2
48 -5.5.5 -68.5
49.5
-53.9
49.5
-65.6
49.0
-53.4
49.0
-64.6
48.5
-52.9
48.5
-63.6
47.9
-52.4
47.9
-62.7
47.4
-51.9
47.4
-61.7
46.8
-51.3
46.8
-60.7
46.3
-50.8
46.3
-59.7
45.7
-50.3
45.7
-58.8
45.2 45.2 44.7 44.7
-49.8 -57.8 -49.3 -56.8
51.8 51.8
51 -56.2 -69.4
50.2
-54.6
50.2
-66.4
49.6
-54.1
49.6
-65.4
49.1
-53.6
49.1
-64.4
48.5
-53.1
48.5
-63.5
48.0
-52.5
48.0
-62.5
47.4
-52.0
47.4
-61.5
46,9
-51.5
46.9
-60.5
46.3
-50.9
46.3
-59.5
45.8 45.8 45.2 45.2
-50.4 -58.5 -49.9 -57.5
52.4 52.4
54 1 -56.9 1 -70.2 1
50.8
-55.3 1-67.2
50.8
50.2
-54.8
50.2
-66.2-54.2
49.7
49.7
-65.2
49.1
-53.7
49.1
-64.2
48.6
-53.2
48.6
-63.2
48.0
-52.6 1
48.0
-62.2
47.4
-52.1
47.4
-61.2
46.9
-51.6
46.9
-60.2
46.3 46.3 45.8 45.8
-59.2 -50.5 -58.2
• • 53.0L53.0
•57
•53.1
•-58
51.451.4
-55.9
519
-56.5
-68.0
519
-68.7
50.8
-55.4
514
-56.0
50.8
-67.0
514
-67.7
50.2
-548
508
-SS.4
50.2
-66.0
508
-66.7
49.7
-54.3-58.9
502
-54.9
49.7
50.2
-65.7
49.1
496
-54.4
49.1
496
-64.6
48.6
491
-53.8
48.6
491
-63.6
48.0
485
-53.3
48.0
485
-62.6
47.4
479
-52.7
474
47�46.8
-6
4�lt 11111�!4itf f,46.3 46.3
-(!0 - ,59.
• • . •
•••
;;....
PERMIT No. 77012
_
Miami Shcres Village
8Y DATE STAT F c�
APFRO'ED ? -o
ZONING DEPT
BLDG DEPT
SUBJECT fo CCMPLIA.NCE WITH ALL FEDERAL^ `
v
W,
W
w
�r
W
LI
72 7/4 X 49 3/8 73 1 /2 X 80
FL 16736.1 FL 11103.1 •
0 00
• . ••. ..'
110 X 49 3/8
(+/-60) 0 • • • . • •
FL 16736.2 : • . • . • • • .
•
FAMILY �" .••
35 3/4 X 36 3/4
(+/-60)
FL 16736.1
�s
E
v
A BATH�
T
H BATH o
KIT
ws
72 7/8 X 49 3/8
(+/-60)
FL 16736.1
6 >
LIVING
C� ENTRY
3L& 0>
110 X 49 3/8
(+/-60)
FL 16736.2
GARAGE
J Z•
Q1
U
00
41
ai
z
ry
r
>-
cc
G
�,.
f.,..
72 7/8 X 49 3/8
(+/-60)
FL 16736.1
l7
,a
V-4
b
W. Lt:
fr.
uj
f+�
D
72 7/8 X 49 3/8
B E D 2-
(+/-60) (+/-60)
W Q
1L
FL 16736.1
W 00
[Y.
iii
t
n
�
+K
�
N
Q
1,
72 7/8 X 49 3/8
(+/-60)
16736.1
rFL
O
u,
`r
N s
r.r
L
LI
72 7/4 X 49 3/8 73 1 /2 X 80
FL 16736.1 FL 11103.1 •
0 00
• . ••. ..'
110 X 49 3/8
(+/-60) 0 • • • . • •
FL 16736.2 : • . • . • • • .
•
FAMILY �" .••
35 3/4 X 36 3/4
(+/-60)
FL 16736.1
�s
E
v
A BATH�
T
H BATH o
KIT
ws
72 7/8 X 49 3/8
(+/-60)
FL 16736.1
6 >
LIVING
C� ENTRY
3L& 0>
110 X 49 3/8
(+/-60)
FL 16736.2
GARAGE
J Z•
BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge It Stats B Facts I Publications I Contact Us I BCIS Site Map I Links Search
Ft rich p _
.,. Product Approval
r
� USER: Public User
a kp� ..KK "
Product Annroval Mend > Product nr Annliration
Cearrh > Annlira Inn I Nt > Application Detail
FL #
FL16736-R2
Application Type
Revision
Code Version
•
2017
Application Status
Approved
Comments
• 26M
Archived
( 1
Product Manufacturer
Custom Window Systems Inc.
Address/Phone/Email
1900 SW 44th Avenue
Ocala, FL 34474
• • • 0 • •
(352) 368-6922 Ext 291
•
•
jlathrop@cws.cc
Authorized Signature
Kevin Pine
14994
kpine@cws.cc
Technical Representative ]ay Lathrop
Address/Phone/Email 1900 SW 44th Ave
Ocala, FL 34474
(352) 368-6922 Ext 291
jlathrop@cws.cc
Quality Assurance Representative Arturo Monteverde
Address/Phone/Email 1900 SW 44th Ave
Ocala, FL 34474
(352) 368-6922 Ext 221
amonteverde@cws.cc
Category Windows
Subcategory Horizontal Slider
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Lucas A. Turner
the Evaluation Report
Florida License PE -58201
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 07/21/2020
Validated By Steven M. Urich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
FL16736 R2 COI EvalReoort871C.Ddf
Referenced Standard and Year (of Standard)
Standard
•
• -Mae
AAMA/WDMA/CSA/101/I.S.2/A440-08
• • • •
• 26M
• • • •
ASTM E1886-05
• •
� 806
• •
•
ASTM E1996-09
• • • 0 • •
• -polis•
•
•
PA/TAS 201/202/203
000.00
14994
0000••
0••0••
0000
•
•0••0:
0000
• •
• •
Equivalence of Product Standards
••�•••
0000
• • • •
Certified By
e•••
•
• •
•• •••
•
0000•
0000••
0000
0000••
• •
•
%•
00%
0
00.0000
• •
0
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
09/28/2017
Date Validated
09/29/2017
Date Pending FBC Approval
10/03/2017
Date Approved
12/12/2017
Summary of Products
FL # Model, Number or Name
Description
16736.1 HS -8200 PVC Horizontal Slider
HS -8200 PVC Horizontal Slider, IMPACT, 74" x 63", XO or OX.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16736 R2 II CWS-871C.Ddf
Approved for use outside HVHZ: Yes
Verified By: Lucas A. Turner 58201
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: +60/-60
Evaluation Reports
Other: Large Missile, 74" x 63", DP +/- 60 psf. Outer lite in
FL16736 R2 AE EvalReoort871C.Ddf
I.G. must be safety glazed when used above 30 ft. in HVHZ.
Created by Independent Third Party: Yes
Glass complies to ASTM E1300-04.
16736.2
HS -8200 PVC Horizontal Slider
HS -8200 PVC Horizontal Slider, IMPACT, 111" x 63", XOX.
Lim is of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16736 R2 II CWS-86cC.Ddf
Approved for use outside HVHZ: Yes
Verified By: Lucas A. Turner 58201
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: +60/-60
Evaluation Reports
Other: Large Missile, 111" x 63", DP +/- 60 psf. Outer lite in
FL16736 R2 AE EvalReDOrt869C.Ddf
I.G. must be safety glazed when used above 30 ft. in HVHZ.
Created by Independent Third Party: Yes
Glass complies to ASTM E1300-04.
Back Next
rontad Ls :: 7601 Blair Stnna Road Tallahassee 199 Phon • as�487-]R24
The State of Florida is an AA/EEO employer, Copyright 2007-2013 State of Florida.:: Privary Statement :: Arr—sihili�Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click here_.
Product Approval Accepts:
®
Credit Card
Safe
...-
0 0•• see*
00 • 000000
• 00 0
000606 • e • 0
00000 00*0 •0060 e
0000 • 0 • e
.00000 00000
• 000. • 6
:00 00 0000:0
0 -
0 ..... 6000:0
• • .
00 0 0e ••••0:
• • . 0
0000
0
TURNER
ENGINEERING &
CONSULTING, INC.
1239 Jabara Ave.
North Port, FL 34288
Ph. 941-380-1574
FBPE C.O.A. #29779
Evaluation Report 869C
September 7, 2017
Product Description: Series 8200 PVC Horizontal Slider Window, Large Missile Impact (HVHZ),
XOX 111 "x63" unit size with design pressures of +/-60 psf (Fin or Flange window)
Manufacturer: Custom Window Systems, Inc. 1900 SW 44`h Ave, Ocala, FL 34474
Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC
Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 6th
Edition (2017) Florida Building Code including the High Velocity Hurricane Zone. The product testing
standards performed are outlined below.
Technical Documentation:
1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL
2) Approval drawing CWS -869C, signed and sealed by Lucas A. Turner, P.E.
3) Test Reports NCTL-210-3887-3, -3A, -4, and 4A, by National Certified Testing Laboratories,
Orlando, FL, signed and sealed by Gerard J. Ferrara, with testing performed: TAS 201, 202, 203
`94, ASTM E 1886'02/04/05, ASTM E 1996'04/06/09, and AAMA/WDMA/CSA
101/I.S.2/A440 `08
4) Supplemental Calculations to support CWS -869C, signed and sealed by Lucas A. Turner, P.E.
Installation: Units must be installed according to approval document CWS -869C.
Limitations of Use: This product:
• May be used up to the sizes and daylight openings indicated in CWS -869C
• Achieves design pressures of +/-60 psf
• Is Large Missile impact resistant and does not require the use of shutters
• May be used in the High Velocity Hurricane Zone
• In the operable sash, requires Kuraray (Dupont) PVB Interlayer per Miami -Dade N.O.A. 16-
1117.021, and in the fixed glass requires Kuraray (Dupont) SentryGlas Interlayer per Miami -Dade
N.O.A. 14-0916.11 t
• Requires Quanex (Mikron) white rigid PVC framing per Miami -Dade N.O.A. 17-0206.1Ot
t I have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and find
that they comply with the requirements of the 6`h Ed. (2017) Florida Building Code for use in this
product.
Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial
interest in Custom Window Systems or in any company manufacturing or distributing products for which
this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest
in any other entity involved in the testing or approval process of this product.
Lucas
Turner
2017-09-16
09:27+20:00
�VAORE by
No 58201
STATE OF �►:
0'�SSrdNAk-
0000
.•, •0000'
999999 • . .
0
. 000
... 0000..
0090 •0000.
.999' • • •
.9.PJ97/201I••. 0000.
Lueas•A' Turq;3.�. • • • • •
:'FVrE #58201 000.: •
• 0000:. •000:0
.. 0 •• 0000.:
HORIZONTAL SLIDER - LARGE MISSILE IMPACT
64 114"
MAX.
OVERALL
FLANGE p
HEIGHT v
63"
MAX.
UNIT
HEIGHT
59 9/16"
MAX.
SASH
HEIGHT
i
27 15/16"
MAX. SASH WIDTH
TABLE OF CONTENTS
112 1/4" MAX. OVERALL FLANGE WIDTH
111" MAX. UNIT WIDTH
49 15/16"
GLASS DLO
A�
561 O GLASS
DLO
A
24 5/8"
GLASS DLO
X561/4"
D GLASS
D
DLO
B
6
C
I 6
1 < I 6
. .
...
.
.
.
...
.. ..
.
. .
..
..
.
. . .
.
. .
. .
.
.
3. CONFIGU:AyOV.'PX;''SCQ". ; • • • •
•
4. DESI E SURE RA1R IS:
TI SOLO S�ASF•�ON TESTED PRESSURE AND
HORZ. SLIDER
IMPACT
GLASS TABLES A TM 13 a /0.•
GLA'
-POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER
_j
ON TEST PRESSURE AND GLASS TABLES
INFILTTASTM
U)Lu¢
. .
...
. .
.
.
...
GENERAL NOTES:VIy=UU(f
�z-
2017-09-22
1.1'1-1)~ PgaQUCT SdCVj(N EREIN IS Q IGN D AND MANUFACTURED
�OFjID4BNI�ING�OtE
WINDOW SYSTEMS
j] jjr'],T
I� / I
•TORCOIMPbY WITW TF{E (FBC), CURRENT
FL PE # 58201
•ED HOWINCLUDINGQH91NGH VELOCITY HWICANE ZONE (HVHZ) AND
1900 SW 44TH AVE.
•
I� RAT�ptOR W *ZONE #MISSILPLE V E LDNMPACT USE AS DEFINED
%
OCALA, FLORIDA 34474
W CWS.CC
IN E 1996 PEW THE FEib.
PH. 941-380-1574
2. GLAZING OPTIONS: (SEE SHEET 2)
8200 PVC
3. CONFIGU:AyOV.'PX;''SCQ". ; • • • •
•
4. DESI E SURE RA1R IS:
TI SOLO S�ASF•�ON TESTED PRESSURE AND
HORZ. SLIDER
IMPACT
GLASS TABLES A TM 13 a /0.•
GLA'
-POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER
_j
ON TEST PRESSURE AND GLASS TABLES
INFILTTASTM
U)Lu¢
E-1300-0401/09.
3 0-04e0 %09.
Z
w J o Z w
LU
ZOZ 0-'--H
00 3:
5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED
0
F w 3 Z X
IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR
Z
O
Z 2 2 ¢ D_ w OO
O
DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD
0
F O V ¢ = F D:
z Z
ANCHOR CALCULATIONS.
z F j N
6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT
THE
Z
a
>_
0CD 70-
-o l z O LL Z
� 3 O M
Z -
REQUIRED. IMPACT ROTARY LOCKS ARE INTENDED TO BE LEFT
REQUIRED.
O
UNLATCHED DURING NORMAL OPERATION OF THIS PRODUCT, BUT
F
WO} j 0
MUST BE ENGAGED PRIOR TO EXPOSURE TO HURRICANE WINDS AND
w
w w U) 00 w � F
FLYING DEBRIS.
wz
= a Of O co
7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT
0
It
wH0 (Lx >
U)
a w 3 w
USED AT FIXED MEETING RAIL AND HEAD/SILL.
a
8. SERIES / MODEL DESIGNATION HS-8200.„`��
%"P,,VSORE W /'14
Q2.;
9. THE DESIGNATION X AND 0 STAND FOR THE FOLLOWING:
OP. ��CENg�."
v
X = OPERABLE SASH, 0 = FIXED SASH
t” No 58201 :�9 L
10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR
- b
LOCATION.
'90 . STATE OF
11. EXTERNAL WEEP SLOT= 1/4" x 1" LOCATED 4" FROM BOTH ENDS.
:'Sc:'FC n
LucasTurne
r
�z-
2017-09-22
9/22/2017
13:54-04:00
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
GENERAL NOTES AND
ELEVATIONS
GENERAL NOTES & ELEVATIONS ........... 1
GLAZING DETAILS.....................................2 TEF 10/11/13
SECTION VIEWS& GLAZING DETAILS....3 MAM63"
ESIGN PRESSURE RATING IMPACT RATING DWG #: REV.:
EXTRUSIONS & B.O.M...............................4 CWS -869C
ANCHOR SCHEDULE& NOTES................5 +/- 60 PSF LARGE MISSILE IMPACT
INSTALLATION DETAILS ...........................6 SCALE: SHEET
1.20 1 OF 6
OUANEX OL
IG SPACER
7/8" OVERALL
3/16" ANNEALED OR TEMPERED
1/4" AIR SPACE
7/16" LAMI
—J-3/16" ANNEALED
.090 SENTRY GLASS IONOPLAST INTERLAYER
3/16" ANNEALED
GLASS TYPE A
FIXED GLASS
.
.
...
.
.
.
...
..
..
.
. .
..
..
.
. .
.
.
. .
.
. .
.
.
.
...
. .
.
.
.. .
.... ... .. ..
• • • • • • • • • • • • •
• • •• • • ••• • ••
• •• • • ••• ••
OUANEX DURASEAL
IG SPACER
.. . . . ..
... ..
. ... . . . .
.. .
f/8"4OVERALL • •
• • • • •
1/8" ANNEALED OR TEMPERED
3/8" AIRSPACE
5/16" LAM
1/8" ANNEALED
-090 DUPONT PVB INTERLAYER
t-
1/8" ANNEALED
GLASS TYPE B
SASH GLASS
PURFECT GLAZE"H"
SIKAFLEX 552
1/2" GLASS BITE
WINDOW SYSTEMS Q-
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CW S.CC
8200 PVC
HORZ. SLIDER
IMPACT
i 3 <,r3:
w Zpz ff ME
0 ~WZO3:�=
ZZ=mafYW00
O OI-0a=FW
U Urn~za-Prn a.
z~—�
Q �jU-
a ZUWZO0
}0wOyZ
w¢3FO
+
OOItai0u�imw
LLUnw OJmI-
aw _
0 w0
m:~ 2 W a m
a F- a ��'Wa
P0REW'TG
CGP�•�-�C E N SF•.'Py
No 58201 "•":m7:5
O; STATE OF ;4/`
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SHEET DESCRIPTION:
GLAZING DETAILS
TEF 10/11/13
VG #: REV.:
CWS -869 C
ALE SHEET
1:1 2 OF 6
. . ... . . . ...
.. .. . . . .. .. .
. . . . . . . . . .
. . ... . . . . ...
INTERIOR
•
INTERIOR
SECTION VIEW A -A
SECTION VIEW B -B
SECTION VIEW C -C
ALTERNATE FIN FRAME
HEAD IMPACT HOOK (TYP.)
MIDSPAN OF SASHES
(ITEMS 44 & 46)
SECTION VIEW D -D
JAMB ROTARY LOCKS
JAMB ROTARY LOCKS:
MAY BE SUBSTITUTED FOR JAMB
IMPACT LOCKS ON FLANGE UNITS.
REQUIRED ON FIN UNITS.
JAMB IMPACT HOOKS (REM 42)
OR ROTARY LOCKS (REM 23)
LOCATED AT THIRD POINTS.
X
i NOTES:
EITHER IMPACT HOOKS OR ROTARY LOCKS
MUST BE USED IN BOTH JAMBS OF FLANGE UNITS.
ONLY ROTARY LOCKS MUST BE USED IN BOTH
JAMBS OF FIN UNITS.
HEAD IMPACT HOOK AND
JAMB IMPACT HOOK/ROTARY LOCK LOCATIONS
1:20
®0 *ffl
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CW S.CC
8200 PVC
HORZ. SLIDER
IMPACT
z 3 az3
I-ow0 OW06
o zivO�Oz
}wm
w �w3z�32x
z zxM¢xwp0
O OFO QxFw
0 Z-D-ZH-n A
Z 00' UVj Do-
HZLLmZowo
>- aOwFm:O-
w w wwowmw
wNa -j
p w1 --O a=�a}i
Of a a wawa
Zv �• No 58201 •:�1� 5
zz
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
SECTION VIEWS
TEF 10/11/13
VG #: REV.:
CWS -869 C
ALE SHEET
1.2 3 OF 6
18 P-3429 jWstp., 0.270 x .187 back FinSeal, Gr,
PARTS LIST
19 P-3783 Lock, Impact, PVC
ITEM PART # DESCRIPTION
VENDOR
1
H-6049 Main Frame, SH/HS, Flange, PVC
Mikron
2
H-1681 Fixed Rail, Heavy Duty, Aluminum
Keymark
3
S-6077 Cover, HD Fixed Rail, PVC
Mikron
5
P-4638 #8 x 2 1/2" Ph Mod Truss Type A TEK
Ajax
6
P-3342 Seam Sealer, SM -5504
Schnee
7
S-1776 Roller Track
Keymark
8
S-6013 Screen Adapter, Jamb, PVC
Mikron
9
S-6014 Screen Adapter, Head & Sill, PVC
Mikron
10
P-4479 Weep Cover w/ Flap
M&M
11
S-6064 lGlazing Bead
Mikron
12
H-6050 Sash Meeting Rail, PVC
Mikron
13
H-6051 ISash Pull Rail, PVC
Mikron
14
H-6052 Sash Top/Bot. Rail, PVC
Mikron
15
H-1497 Reinf. Sash Meet. Rail
Keymark
16
H-1498 Reinforcement, Sash, Side Rail
Keymark
17
H-1699 Reinforcement. Sash Pull Rail
Kevmark
18 P-3429 jWstp., 0.270 x .187 back FinSeal, Gr,
Ultrafab
19 P-3783 Lock, Impact, PVC
Interlock
20 P-4051 #8 x 1 1/4" Ph Flat Tek, Wht.
Fastenal
21 P-4069 Keeper, Impact, PVC
Interlock
22 P-3539 #8 x 3/4" Square PH Tek, Wht.
Fastenal
23 P-4958 Rotary Lock
Interlock
24 P-4633 832 x 1/2" Barrel Fastener
Interlock
25 P-4952 Keeper, Rotary Lock
Interlock
26 P-4779 Roller, Tandem
M&M
27 P-3541 #8 x 1/2' Quad PH TEK 2 Zinc
Fastenal
28 GLASS SEE SHEET
CARDINAL
29 Purfect Glaze "H" or Sikaflex 552
Henkel/Sika
30 P-3028 Set. Blk., 85 Our., 1/8" x 7/8" x 2" Lg.
Frank Lowe
31 P-3218 Screen Frame
Allmetal
32 P-4754 Screen Comer Key
Allmetal
33 P-4755 Screen Comer Key w/Safety Tab
Allmetal
34 P-3029 Screen Pull tab
Summit
35 P-3033 Screen Spring
Fla. Spring
36 P-3228 Screen Spline
Dapa
37 P-4772 Screen Cloth, Fiberglass
40 P-3113 Screw Support, PVC
Team Plastics
41 P-3752 Cap Plug, 1/2" Hole
M&M
42 S-1577 Impact Hook, Frame, Jamb
Keymark
43 S-1112 Reinforcement, Head, Jamb
Keymark
44 S-2000 Impact Channel, Sash
Keymark
45 P-3748 #6 X 5/8 Ph FH TEK, Zinc, Painted
Ajax
46 S-1999 Impact Hook, Frame, Head
Keymark
47 H-6048 Main Frame, SH/HS, Fin, PVC
Mikron
48 S-6055 Roller Track, PVC, (Anti4ift)
Mikron
49 P-5250 Lock, Impact, PVC, w/Flipper
Interlock
50 P-4730 #8 x 1/2" Ph Mod Truss TEK
Fastenal
PVC
Alum ,
PVC
Steel 2 11/16" 3
1/16'
ilicane Lr
Alum
PVC
PVC PVC FRAME FLANGE -6049
PVC
PVC
PVC
PVC
Alum
Alum
. . ... . . . ...
.. .. . . . .. .. .
. . . . . . . . . .
. ....... ....
31/8"-1 CORNER CONSTRUCTION
• • 3 M8" •
ins". � •
�O fij 6 1116" •
LCORNER WELD
• • • • • • • • • • • (ALL SIDES)
1" • • 'lib" • • • • • 1:8
• • : • : �D @TC:V11 t •
PVC FRAME FIN -6048 • • • • • • • •
•• • • • • • ••• ••
6
2 3116" 1 15/16" -1 3/16"-{ 5
2 3/16"
^ 13
5/8" 1 5/8" `� 1 5/8" 1 5/16"
1/16' 1/16" q 1/16" 1/16
1 I q ' 2
PVC SASH MTG. RAIL -6050 PVC SASH SIDE RAIL -6051 PVC SASH TOPIBTM RAIL -6052 PVC HD MTG RAIL COVER- 6077 FIXED MEETING RAIL
0 3/16• SCREWED TOGETHER WITH
OUTERFRAME
1:8
Steel 0
I 7l8" 5/1Lr""Steel 6" �5116 ya
,5n" •
"
SASH MTG. RAIL -1497 L
Nylon PLAN VIEW -1999 SASH REINF. - 1699
HEAD IMPACT HOOK - 1999 Steel 0 �{I
GLASS 3/16" 3/16"� 3/4" 7/16"
O 7
Silicone
Rubber 1/16^
16
6" 5/8" S.B.R./S.S.R.- 1498 1116'
2ollFom1 T 44 ROLLER TRACK -1776
Nylon 5/L 1/16"
Nylon PLAN VIEW -2000 1/4"
PANEL IMPACT CATCH -2000 11r7/8"1
7/8'
SS 0 3/16" L 9116 43
O 6 PVC GLAZEBEAD - 6064
GLAZE BEAD - 1112
Rubber � ,/2" , 1/8^
Nylon 5116* 3/8' 3l6"�5/16Alum 41/16Alum 7/1/16" PVC SCREEN CATCH • 6013
Alum PLAN VIEW - 1577 ALUM SASH IMPACT HOOK - 1577 PVC ANTI -LIFT - 6005
Steel 5/16"�11/8"-iI
Alum 3/16—t 3' �1/2" . i
PVC I 40 Tlp-L1//11(66"")
PVC T
SCREW SUPPORT - 3113 PVC SCREEN SUPPORT • 6014
Steel LINE ITED:MS NOT USE
4, 38-39 NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED.
Qm
WINDOW SYSTEMSffl
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
8200 PVC
HORZ. SLIDER
IMPACT
ZaZ3
P 0w0 WwFO p
w Zpz XFZF
o Pw�ZI-3gx
O OHO
¢=IfoU Uy?aI-tqa
zQ_n-
j0-
>- zDOu-Z
v
W O0O }
W �Nwtg0 Jtnw
a
W =~W W�W(n
a a
%01,11111111",
���1NORE W ����i
JGgSP. S
.�CEN�:�•Qyt�:
58201 11 L
390: STATE OF :4utt/
F
;
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
BOM AND EXTRUSIONS
TEF 1 10/11/13
CWS -869 C
:ALE: SHEET
1:2 40F6
6" MAX. (TY]
6" MAX. (TYI
17"
MAX O.C.
(TYP.)
f
ANCHOR LAYOUT - (FLANGE)
IOTE 2 4" MAX. (TYF
4" MAX. (TYF
INSTALLATION
ANCHOR (TYP.)
e"
MAX. O.C.
(TYP.)
.
.
...
.
.
.
...
..
..
.
. .
..
..
.
.
. .
.
. .
. .
.
.
.
.......
....
.... ... .. ..
. . . . . . . . . . . . .
ANCHOR LAYOUT - (FIN)
NOTES:
1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD.
2. SHIM AS REO AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE
CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED.
3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6.
4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST
BE PROTECTED TO PREVENT REACTION.
5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM
SPECIFIED IN TABLE 1, SHEET 6.
6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE.
INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.
INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.
7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD AND METAL
8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE.
SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLE1, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED.
9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS:
FMA/AAMA100(FINWINDOWS),FMA/AAMA200(FLANGEWINDOWS), FMANVDMA250(BOXWINDOWS),FMA/AAMA/WDMA300(EXTERIORDOORS)
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
8200 PVC
HORZ. SLIDER
IMPACT
Z �: <Z3
Z w J❑ U w Ow
❑ Z0Z OD'Zm_
u- Hw3ZF-��S
Z zmm<wwoo
0 0I-0cj¢=�-it
' ❑ ZOZI-Dy
Z OU'j 7U-
P-'�OoLL
>-¢:OwFmOZ
¢
UJ OOwv}i0wv�w
2 zea 0-1Ln-
co
O wFZ-0 W=If>-
w s H a mea
0"Pp1ORE W I
0lo
CENSFG'P2L
No 58201 :kNN11
=ros
STATE OF
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
ANCHOR SCHEDULE AND
NOTES
TEF 10/11/13
VG #: REV.:
CWS -869 C
:ALE: SHEET
1.25 5 OF 6
INSTALLATION ANCHOR
SEE TABLE 1
1/4' MAX. SHIM
SEALANT BEHIND
FLANGE BY INSTALLER X770
PERIMETER SEALANT 9 MIN. EMBEDMENT
BY INSTALLER SEE TABLE 1
INSIDE AND OUT VA i
SUBSTRATE BY OTHERS r / i
SEE TABLE 1 MIN. EDGE DIST.
SEE TABLE 1
r(�A) VERTICAL SECTION
TYPICAL SILL ANCHORAGE
CHOR TYPE
6" ITW TAPCON
. . ... . . . ...
.. .. . . . .. .. .
. . . . . . . . . .
. . ... . . . . .. .
TYPICAL HEAD ANCHORAGE
MIN. EDGE DIST.
OPERIMETER SEALANT
SEE TABLE 1
SUBSTRATE BY OTHERS
BYINSTALLER
INSIDE AND OUT
SEE TABLE 1
Z O Z
Q In 3 } O 0_ 3: m
INSTALLATION ANCHOR
MIN. EMBEDMENT
PERIMETER SEALANT
SEE TABLE 1
BY INSTALLER
• •
INSIDE AND OUT
�/(f1U•N/(Yll//UL/U' n('��
O O � U m
? O Z
BY OTHER6 • •
SEALANT BEHIND
• • • • •
FLANGE BY INSTALLER
1/4' MAX. SHIM
INSTALLATION ANCHOR
SEE TABLE 1
1/4' MAX. SHIM
SEALANT BEHIND
FLANGE BY INSTALLER X770
PERIMETER SEALANT 9 MIN. EMBEDMENT
BY INSTALLER SEE TABLE 1
INSIDE AND OUT VA i
SUBSTRATE BY OTHERS r / i
SEE TABLE 1 MIN. EDGE DIST.
SEE TABLE 1
r(�A) VERTICAL SECTION
TYPICAL SILL ANCHORAGE
CHOR TYPE
6" ITW TAPCON
. . ... . . . ...
.. .. . . . .. .. .
. . . . . . . . . .
. . ... . . . . .. .
PERIMETER SEALANT
BY INSTALLER
INSIDE AND OUT
SEALANT BEHIND
FLANGE BY INSTALLER
B HORIZONTAL SECTION
6 TYPICAL JAMB ANCHORAGE
FLANGE GROUT -FILLED CMU (ASTM C-90) 3/16" ELCO ULTRACON 1-1/4" 2-1/2"
FLANGE 2X MIN. SOUTHERN PINE (G=0.55) 3/16" ITW TAPCON 1-3/8" 7/8"
OR ELCO ULTRACON
16 GAUGE (0.060-) MN. STEEL STUD #10-16 HLTI KWIK-FLEX OR ITW FULL THREAD
FLANGE (33 KSI YIELD MIN) TEKS SELF-DRLLING SCREW THRU 0.060" 7/16"
1/8" ALUM. (W631 -T5 MN.) OR #10 GRADE 5 SELF -TAPPING/ FULL THREAD
FLANGE 1/8" STEEL (33 KSI MN.) DRILLING SCREW THRU 0.125" 7/16"
z 3 aza
OPERIMETER SEALANT
W
MIN. EMBEDMENT
BYINSTALLER
INSIDE AND OUT
O
Z O Z
Q In 3 } O 0_ 3: m
INSTALLATION ANCHOR
Z
SEE TABLE 1
SUBSTRATE•
•
• •
FIN BY INSTALLER
�/(f1U•N/(Yll//UL/U' n('��
O O � U m
? O Z
BY OTHER6 • •
•
• • • • •
• • •
WINDOW SYSTEMS I\ �/I
1/4" MAX SHIM
SEE TABLE 1 • •
• •
•
• •
• MW. E!GT•DIST. •
SINE T{.BLi 6 • •
• • SUBSTRATE
• • BY OTHERS
1900 SW 44TH AVE.
Wa J
�• •
• •
•
•
• • • •
1/4 4MAX. SHI41 •
• SEE TABLE 1
• •
OCALA, FLORIDA 34474
WWW.CWS.CC
a
MIN. EDGE DIST.
'L�9
SEE TABLE 1
No 58201
. •
8200 PVC
INSTALLATION ANCHOR
SEE TABLE 1
G
• •
N AL
O
HORZ. SLIDER
/ • •
•
: • : 0 0 • • •
MIN. EMBEDMENT
IMPACT
/ ••
•
•
• • • •
• •
SEE TABLE 1
PERIMETER SEALANT
BY INSTALLER
INSIDE AND OUT
SEALANT BEHIND
FLANGE BY INSTALLER
B HORIZONTAL SECTION
6 TYPICAL JAMB ANCHORAGE
FLANGE GROUT -FILLED CMU (ASTM C-90) 3/16" ELCO ULTRACON 1-1/4" 2-1/2"
FLANGE 2X MIN. SOUTHERN PINE (G=0.55) 3/16" ITW TAPCON 1-3/8" 7/8"
OR ELCO ULTRACON
16 GAUGE (0.060-) MN. STEEL STUD #10-16 HLTI KWIK-FLEX OR ITW FULL THREAD
FLANGE (33 KSI YIELD MIN) TEKS SELF-DRLLING SCREW THRU 0.060" 7/16"
1/8" ALUM. (W631 -T5 MN.) OR #10 GRADE 5 SELF -TAPPING/ FULL THREAD
FLANGE 1/8" STEEL (33 KSI MN.) DRILLING SCREW THRU 0.125" 7/16"
/PERIMETER SEALANT— \
BY INSTALLER
INSIDE AND OUT ^
L l HORIZONTAL SECTION
6 BOX FRAME INSTALLATION
HEAD AND SILL SIMILAR FOR BOX INSTALLATION
FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE,
UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED:
MIN. 1/4" FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED
INSIDE AND OUT, FULL PERIMETER, BY INSTALLER.
PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS
SHOWN FOR FLANGE WINDOWS.
X:�_-
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
INSTALLATION DETAILS I
TEF 10/11/13
JG #: REV.:
CWS -869 C
ALE: SHEET
1:2 6OF6
z 3 aza
OPERIMETER SEALANT
W
owo
W
Z X=
BYINSTALLER
INSIDE AND OUT
O
Z O Z
Q In 3 } O 0_ 3: m
INSTALLATION ANCHOR
Z
Z= Q~ 3 2_
SEE TABLET
SEALANT BEHIND
O
U~OV =Om
F- z F- CO (L
z -
FIN BY INSTALLER
Z0
O O � U m
? O Z
! C� HORIZONTAL SECTION
6
ao
>_
O O
Q = O
TYPICAL FIN ANCHORAGE
HEAD AND SILL SIMILAR FOR FIN INSTALLATION
Q
Ow
y U F-
Z N
F-
w
D O_(n 0 W y W
(n
o
Wa J
w�a �3wco
(L
a
01DRE W ('16
'L�9
No 58201
STATE OF
G
N AL
O
/PERIMETER SEALANT— \
BY INSTALLER
INSIDE AND OUT ^
L l HORIZONTAL SECTION
6 BOX FRAME INSTALLATION
HEAD AND SILL SIMILAR FOR BOX INSTALLATION
FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE,
UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED:
MIN. 1/4" FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED
INSIDE AND OUT, FULL PERIMETER, BY INSTALLER.
PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS
SHOWN FOR FLANGE WINDOWS.
X:�_-
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
INSTALLATION DETAILS I
TEF 10/11/13
JG #: REV.:
CWS -869 C
ALE: SHEET
1:2 6OF6
L1a11LL�7 Ca ' = Aw,——
�L X4 1
SCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications Contact Us I BCIS Site Map I Links I Search
Florida
P m1 Product Approval ra
..trr�-eree �� USER: Public User
SP-�t 1-44' r
Equivalence of Product Standards
Certified By
Product Annrnval Menti > Product or Annliratlnn CParrh > Annllratlnn LN > Application Detail
FL # FL16736-R2
Application Type
Revision
Code Version
CApproved
2017
Application Status
Comments
Archived
�7
Product Manufacturer
Custom Window Systems Inc.
Address/Phone/Email
1900 SW 44th Avenue
Ocala, FL 34474
(352) 368-6922 Ext 291
jlathrop@cws.cc
Authorized Signature
Kevin Pine
kpine@cws.cc
Technical Representative
Jay Lathrop
Address/Phone/Email
1900 SW 44th Ave
Ocala, FL 34474
(352) 368-6922 Ext 291
jlathrop@cws.cc
Quality Assurance Representative
Arturo Monteverde
Address/Phone/Email
1900 SW 44th Ave
Ocala, FL 34474
(352) 368-6922 Ext 221
amonteverde@cws.cc
Category
Windows
0000
Subcategory
Horizontal Slider • •
• • • •
• • • • • •
•• •
• ••
•
Compliance Method
Evaluation Report from a Florida Registere& ri lti& t or Licer"el
• • • • i •
Florida Professional Engineer • • • • • •
•
•
0 Evaluation Report - Hardcopy Received • • • •
•
• • • •
• • • •
••••
••••
•••••
Florida Engineer or Architect Name who developed
Lucas A. Turner • • • • • •
• • • •
• • • • •
the Evaluation Report
• •
•
Florida License
•• ••
PE -58201
••••
••••••
•
Quality Assurance Entity
Keystone Certifications, Inc. i • • i e i
'
•
Quality Assurance Contrail Expiration Date
• •
07/21/2020
• •
• • • • • •
•
• • • • • •
Validated By
•
Steven M. Urich, PE • •• •
•
• •
I Validation Checklist - Hardcopy Receive(?* •
• •
• • • • • •
• •
• •
Certificate of Independence
FL16736 R2 COI EvalReoort871C.Ddf
Referenced Standard and Year (of Standard)
Standard
Year
AAMA/ W D MA/CSA/ 101/I. S. 2/A440-08
2008
ASTM E1886-05
2005
ASTM E1996-09
2009
PA/TAS 201/202/203
1994
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
09/28/2017
Date Validated
09/29/2017
Date Pending FBC Approval
10/03/2017
Date Approved
12/12/2017
Summary of Products
r i
FL # Model, Number or Name
Description
16736.1 HS -8200 PVC Horizontal Slider
HS -8200 PVC Horizontal Slider, IMPACT, 74" x 63", XO or OX.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16736 R2 II CWS-871C.pdf
Approved for use outside HVHZ: Yes
Verified By: Lucas A. Turner 58201
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: +60/-60
Evaluation Reports
Other: Large Missile, 74" x 63", DP +/- 60 psf. Outer lite in
FL16736 R2 AE EvaIReDOrt871C.Ddf
I.G. must be safety glazed when used above 30 ft. in HVHZ.
Created by Independent Third Party: Yes
Glass complies to ASTM E1300-04.
16736.2
HS -8200 PVC Horizontal Slider
HS -8200 PVC Horizontal Slider, IMPACT, 111" x 63", XOX.
LimitsofUse
Installation Instructions --
Approved for use in HVHZ: Yes
FL16736 R2 II CWS-869C.Ddf
Approved for use outside HVHZ: Yes
Verified By: Lucas A. Turner 58201
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: +60/-60
Evaluation Reports
Other: Large Missile, 111" x 63", DP +/- 60 psf. Outer lite in
FL16736 R2 AE EvalReDort869C.Ddf
I.G. must be safety glazed when used above 30 ft. in HVHZ.
Created by Independent Third Party: Yes
Glass complies to ASTM E1300-04.
Back Next
Contact U ;: 2601 Blair Stonp Road. Tallahass FL 171gq Phone- R50 -4874R24
The State of Florida is an AA/EEO employer. Coovrioht 2007-2013 State of Florida.:: Privary Statement :: Arressihility Statement :: Refund qGtem, nit
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a ppeft"41ddress,
please provide the Department with an email address which can be made available to the public. To determine if you are a licWsee unger Chapter 4SSr F.S.,,^ase
click here . • • • • •
Product Approval Accepts: • • • • • •
MW 0j H M • • •
eCta:k •••••• •.••
•
Credit Card • • • • • • • •
Safe •••• ••••
...... ....
••••••
• .
TURNER
ENGINEERING &
CONSULTING, INC.
1239 Jabara Ave.
North Port, FL 34288
Ph. 941-380-1574
FBPE C.O.A. #29779
Evaluation Report 871C
August 29, 2017
Product Description: Series 8200 PVC Horizontal Slider Window, Large Missile Impact (HVHZ), XO
or OX 74"x63" unit size with design pressures of +/-60 psf (Fin or Flange window)
Manufacturer: Custom Window Systems, Inc. 1900 SW 44"' Ave, Ocala, FL 34474
Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC
Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 6"'
Edition (2017) Florida Building Code including the High Velocity Hurricane Zone. The product testing
standards performed are outlined below.
Technical Documentation:
1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL 090000
2) Approval drawing CWS -871C, signed and sealed by Lucas A. Turner, P.E. ; 0.0 • • • •
3) Test Reports NCTL-210-3887=1, -IA, -2, and -2A, by National Certified Testing LtboraGoride,
Orlando, FL, signed and sealed by Gerard J. Ferrara, with testing performed-�'1.W201, 2620203
`94, ASTM E 1886'02/04/05, ASTM E 1996'04/06/09, and AAMA/WDMNO.8
101/I.S.2/A440 `08 0.000' '....'
4) Supplemental Calculations to support CWS -871C, signed and sealed by LucasI4.•Turner, Fk&
000000 •0:0
Installation: Units must be installed according to approval document CWS -871C.
Limitations of Use: This product: •
• May be used up to the sizes and daylight openings indicated in CWS -871C
• Achieves design pressures of +/-60 psf
• Is Large Missile impact resistant and does not require the use of shutters
• May be used in the High Velocity Hurricane Zone
• Requires Kuraray (Dupont) PVB Interlayer per Miami -Dade N.O.A. 16-1117.021
• Requires Quanex (Mikron) white rigid PVC framing per Miami -Dade N.O.A. 17-0206.101
1 I have evaluated the materials in these NOAs and find that they comply with the requirements of the
6'h Ed. (2017) Florida Building Code for use in this product.
Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial
interest in Custom Window Systems or in any company manufacturing or distributing products for which
this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest
in any other entity involved in the testing or approval process of this product.
Lucas
Turner
2017-08-30
16:09+20:00
��11uu11rri�
jCRE W T�'f.
,000..
�r :� • No 58 01 : fi
Q %� STATE OF
.�
' '•�.° �`'��.`�
,��''
8/29/2017
`��,
Lucas A. Turner P.E.
1.41
FL PE #58201
. . ... . . . ...
.. .. . . . .. .. .
. . . . . . . . . .
. . ... . . . . .. .
751/4" MAX. OVERALL FLANGE WIDTH
.. . . . .. ... ..
74" MAX UNIT WIDTH • • • •
• ••• • • • •• •
33" GLASS DLO • • • • • • • •
A ... . .
I I I
I � I
64 1/4"
MAX.
FLANGE B I B
HEIGHT
I
I
63"
MAX
UNIT
HEIGHT O X 599/16"
SA GHT
5813/1
GLASS
DLO
TABLE OF CONTENTS
GENERAL NOTES & ELEVATIONS ........... 1
SECTION VIEWS & GLAZING DETAILS....2
EXTRUSIONS & B.O.M...............................3
ANCHOR SCHEDULE & NOTES................4
INSTALLATION DETAILS ...........................5
A
33" GLASS DLO -
36 5/16" MAX. SASH WIDTH
2. GLAZING OPTIONS: (SEE SHEET 2)
3. CONFIGURATIONS: "OX", "XO".
4. DESIGN PRESSURE RATING:
-NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND
GLASS TABLES ASTM E -1300-04e01/09.
-POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER
INFILTRATION TEST PRESSURE AND GLASS TABLES
ASTM E -1300-04e01109.
5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED
IN THE DESIGN OF THIS PRODUCT. SEE SHEET 5 FOR ANCHOR
DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD
ANCHOR CALCULATIONS.
6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT
REQUIRED. THE IMPACT ROTARY LOCKS ARE INTENDED TO BE LEFT
UNLATCHED DURING NORMAL OPERATION OF THIS PRODUCT, BUT
MUST BE ENGAGED PRIOR TO EXPOSURE TO HURRICANE WINDS AND
FLYING DEBRIS.
7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT
USED AT FIXED MEETING RAIL AND HEAD/SILL.
8. SERIES / MODEL DESIGNATION HS -8200
9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING:
X = OPERABLE SASH, O = FIXED SASH
10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR
LOCATION.
11. EXTERNAL WEEP SLOT = 1/4"x 1" LOCATED 4" FROM BOTH ENDS.
I MAX. UNIT SIZE I DESIGN PRESSURE RATING I IMPACT RATING
L 74" x 63" 1 +/- 60 PSF I LARGE MISSILE IMPACT
LucasTurne
r
2017-09-22
13:58-04:00
8200 PVC
HORZ. SLIDER
IMPACT
g z 3 azp
W zOz WM-
LL O FW7d3}0�m=
z zx2
O Ce -0 �_�M
U Uy�ZaFya
zOza0ozOVZa H-IL2Ooa
�30FFF0-
ZU
mw OJInF
a.
CL
O w�-0 W=�>_
a F a w�a
GpS:�`GENs�;��Q,y
Z-.- No 58201 ":�71
Q: STATE OF 144/'
.,oss,alVA
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
GENERAL NOTES AND
ELEVATIONS
ADE 1 10/10/13
CWS -871 C
ALE: SHEET
1:15 1 OF 5
GENERAL NOTES:
HORIZONTAL SLIDER - LARGE MISSILE IMPACT
QV&
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED
• • • • • • • • • •
•••
• • •
TO COMPLY WITH THE FLORIDA BUILDING CODE( FBC) . CURRENT
• • • • • • • • •
• • •
EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND
1900 SW 44TH AVE.
• • • • • •
• •
IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED
OCALA, FLORIDA 34474
• • • • •
• • • • •
IN ASTM E 1996 PER THE FBC.
WWW.CWS.CC
751/4" MAX. OVERALL FLANGE WIDTH
.. . . . .. ... ..
74" MAX UNIT WIDTH • • • •
• ••• • • • •• •
33" GLASS DLO • • • • • • • •
A ... . .
I I I
I � I
64 1/4"
MAX.
FLANGE B I B
HEIGHT
I
I
63"
MAX
UNIT
HEIGHT O X 599/16"
SA GHT
5813/1
GLASS
DLO
TABLE OF CONTENTS
GENERAL NOTES & ELEVATIONS ........... 1
SECTION VIEWS & GLAZING DETAILS....2
EXTRUSIONS & B.O.M...............................3
ANCHOR SCHEDULE & NOTES................4
INSTALLATION DETAILS ...........................5
A
33" GLASS DLO -
36 5/16" MAX. SASH WIDTH
2. GLAZING OPTIONS: (SEE SHEET 2)
3. CONFIGURATIONS: "OX", "XO".
4. DESIGN PRESSURE RATING:
-NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND
GLASS TABLES ASTM E -1300-04e01/09.
-POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER
INFILTRATION TEST PRESSURE AND GLASS TABLES
ASTM E -1300-04e01109.
5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED
IN THE DESIGN OF THIS PRODUCT. SEE SHEET 5 FOR ANCHOR
DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD
ANCHOR CALCULATIONS.
6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT
REQUIRED. THE IMPACT ROTARY LOCKS ARE INTENDED TO BE LEFT
UNLATCHED DURING NORMAL OPERATION OF THIS PRODUCT, BUT
MUST BE ENGAGED PRIOR TO EXPOSURE TO HURRICANE WINDS AND
FLYING DEBRIS.
7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT
USED AT FIXED MEETING RAIL AND HEAD/SILL.
8. SERIES / MODEL DESIGNATION HS -8200
9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING:
X = OPERABLE SASH, O = FIXED SASH
10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR
LOCATION.
11. EXTERNAL WEEP SLOT = 1/4"x 1" LOCATED 4" FROM BOTH ENDS.
I MAX. UNIT SIZE I DESIGN PRESSURE RATING I IMPACT RATING
L 74" x 63" 1 +/- 60 PSF I LARGE MISSILE IMPACT
LucasTurne
r
2017-09-22
13:58-04:00
8200 PVC
HORZ. SLIDER
IMPACT
g z 3 azp
W zOz WM-
LL O FW7d3}0�m=
z zx2
O Ce -0 �_�M
U Uy�ZaFya
zOza0ozOVZa H-IL2Ooa
�30FFF0-
ZU
mw OJInF
a.
CL
O w�-0 W=�>_
a F a w�a
GpS:�`GENs�;��Q,y
Z-.- No 58201 ":�71
Q: STATE OF 144/'
.,oss,alVA
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
GENERAL NOTES AND
ELEVATIONS
ADE 1 10/10/13
CWS -871 C
ALE: SHEET
1:15 1 OF 5
INTERIOR
SECTION C -C
ALTERNATE FIN FRAME
.
.
...
.
.
.
...
..
..
.
. .
..
..
.
. .
.
.
. .
. .
.
.
.
.
...
. .
.
.
.. .
e • • • • i I)iTERIOR
• • •• • • ••• •
•
s •
X
SAD
vAND SILL IS SIMILAR.
HEAD IMPACT HOOK (TYP.)
MDSPAN OF SASH
(ITEMS 35 & 36)
HEAD IMPACT HOOK AND
JAMB ROTARY LOCK LOCATIONS
1:20
ROTARY LOCK (TYP.)
ONLY ENGAGED PRIOR
TO HURRICANE FORCE WINDS.
LOCATED AT THIRD POINTS
(ITEM 27)
GLASS TYPE A
1:1
7/8' OVERALL
1/8" ANNEALED or TEMPERED
7/16" AIRSPACE
5/16' LAMI
1/8' ANNEALED
.4.24 DUPONT PVB INTERLAYER
1/8" ANNEALED
PURFECT GLAZE"H"
SIKAFLEX 552
—1/2" GLASS BITE
OUANEX DURASEAL
IG SPACER
WINDOW SYSTEMS
ffl
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
8200 PVC
HORZ. SLIDER
IMPACT
g z 3 azo
h ;-Duo 086
w z0? wL9w
0 zw1 >-OW3,m
LL I -w �32x
z z�zd
o ox7o Oyu
I-- a. o_
m
Z O�Uryj�7V�
a p: zo0u-
a WI} -, Zai
z_Wcow
mwm0-)mF-
a MM
a m a W: :w
VIORE W
P T �i+
P5'�CENg•G,p+++
0 -'� �' Z
N. 58201 .'tn215
n - ; cc
OF WS
'+LO�c�`S'�'�
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
IEET DESCRIPTION:
SECTION VIEWS AND
GLAZING DETAIL
LAWN BY: DATE:
ADE 10/10/13
VG #: REV.:
CWS -871 C
:ALE: SHEET
1.2 2OF5
• • • • • • • • • •
• • ••• • • • • •••
31
31 "
-{
• • 1 1/2'
• • • • 8 • 5
• • • • • • • 1/16"
211/16" 1/16' 39/16' O 21/� 1/16'
L O
• • • • • • • • • • • FIXED RAIL - 1836
PVC PRA111E MAIlGE60M • • •
•• • •
• • • • • • • • ••• VC FRAME FIN -6048
• • •••
23/16' /Fr" —19/1 s"
6 I 4
7 r L)
40
15/8" 15I/8" `-J 15/8" q 15/16"
1/16' I q 1/16' q 1/16" ,/16"
PVC SASH MTG. RAIL -6050 PVC SASH SIDE RAIL -6051 PVC SASH TOP/BTM RAIL -6052 PVC FOXED RAIL COVER - 6063
0 3/16"
O
6" 15/16"
35
7/8" 1/16"
PLAN VIEW -1999 HEAD ACT HOOK- 1999
0 3/16"
O
6"
5/8"
T— 36
5/8' 1116-
1
PLAN VIEW -2000 PANEL IMPACT CATCH - 2000
3/16•
3- 1/2 -
SCREW
1/2"
SCREW SUPPORT -3113
LINE ITEMS NOT USED: 1 NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED.
33
5/8
" �----I
I," '
L ,n6"
SASH MTG. RAIL -1497
3/16" --1-1
3
3/4' j—
T I
1/16'
S.B.R./S.S.R. - 1498
va°
PVC GBEAD - 6064
CORNER CONSTRUCTION
�q
WINDOWSYSTEMS KO
PARTS LIST
ITEM
PART #
DESCRIPTION
VENDOR
MATERIAL
1
H-1497
Reinf. Sash Meet. Rail
Keymark
Alum
2
H-1699
Reinf. S.B.R./S.S.R,
Keymark
Alum
3
H-1836
Meet. Rail, Fxd.
Keymark
Alum
4
H-6052
Sash Top/Bot. Rail
Mikron
PVC
5
H-6048
Main Fr., SH, w/ Fin., PVC
Mikron
PVC
6
H-6050
Sash Meet. Rail, PVC
Mikron
PVC
7
H-6051
Sash Side Rail, PVC
Mikron
PVC
8
H-6049
Main Fr., SH, w/Flg., PVC
Mikron
PVC
9
P3029
Screen Pull Tab
Summit
10
P3033
Screen Spring, SS
Hurley
11
P3113
Screw Support, PVC
Team Plastic
Rubber
12
P-3218
Screen Frame
Allmetal
RoI"'or"
13
P3228
Screen Spline, .155 Dia., Bilk.
Dapa
14
P-4754
Screen Frame Comer Key
Allmetal
Nylon
15
P-3342
Seam Sealer, SM -5504
Schnee
Silicone
16
P3352
Set. Blk., 85 Dur., 1/8" x 5/8" x 2" Lg.
FrankLowe
Rubber
17
P3429
Wstp., 0.270 x .187 back FinSeal, Gn
Uftrafab
18
P-3539
#8 x 3/4" Square TEK 2 21nc
Fastenal
Steel
19
P-4730
#8 tF 1/2• Truss PH TEK 2 Zinc
Fastenal
Steel
20
P-3752
Cap Plug, 1/2" Hole
M&M
Nylon
21
7-7=0
P-5250
Spring Lock, Impact, PVC
Interlock
22
P-4779
Roller, Tandem
M&M
Nylon
23
P-4051
#8 x 1 1/4 Ph FH TEK, Wht.
Fastenal
Steel
24
P-4069
Keeper, Impact, PVC
Interlock
25
P-4479
Weep Coker w/ Flap
M&M
Nylon
26
P-4638
#8 x 2 1/2 Ph Truss SMS
Ajax
Steel
27
P-4958
Rotary Lock
Sullivan
Zinc
28
P-4952
Keeper, Rotary Lock
Sullivan
Zinc
29
P-4959
Wstp., 0.420 x.187 back FinSeal, Gn
Ultrafab
30
P-4633
Barrel Fastener
Fastenal
Steel
31
S-1112
Reinforcement, Head
Keymark
Alum
32
S-1498
Reinf. S.B.R./S.S.R,
Keymark
Alum
34
S-1776
Roller Track
Keymark
Alum
35
S-1999
Frame Hook, Head, Impact
Keymark
Alum
36
S-2000
Panel Catch, Head, Impact
Keymark
Alum
37
5-6005
Anti Lift
Mikron
PVC
38
S-6013
Scm. Adapt., w/ Nib, PVC
Mikron
PVC
39
S-6014
Scm. Adapt., PVC
Mikron
PVC
40
S-6063
Fixed Rail Cover
Mikron
PVC
41
S-6064
lGlazing Bead
Mikron
PVC
42
GLASS
ISEE SHEET
CARDINAL
GLASS
43
IPurfect Glaze "H". SikaFlex 552
1 Henkel / Sika
Silicone
• • • • • • • • • •
• • ••• • • • • •••
31
31 "
-{
• • 1 1/2'
• • • • 8 • 5
• • • • • • • 1/16"
211/16" 1/16' 39/16' O 21/� 1/16'
L O
• • • • • • • • • • • FIXED RAIL - 1836
PVC PRA111E MAIlGE60M • • •
•• • •
• • • • • • • • ••• VC FRAME FIN -6048
• • •••
23/16' /Fr" —19/1 s"
6 I 4
7 r L)
40
15/8" 15I/8" `-J 15/8" q 15/16"
1/16' I q 1/16' q 1/16" ,/16"
PVC SASH MTG. RAIL -6050 PVC SASH SIDE RAIL -6051 PVC SASH TOP/BTM RAIL -6052 PVC FOXED RAIL COVER - 6063
0 3/16"
O
6" 15/16"
35
7/8" 1/16"
PLAN VIEW -1999 HEAD ACT HOOK- 1999
0 3/16"
O
6"
5/8"
T— 36
5/8' 1116-
1
PLAN VIEW -2000 PANEL IMPACT CATCH - 2000
3/16•
3- 1/2 -
SCREW
1/2"
SCREW SUPPORT -3113
LINE ITEMS NOT USED: 1 NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED.
33
5/8
" �----I
I," '
L ,n6"
SASH MTG. RAIL -1497
3/16" --1-1
3
3/4' j—
T I
1/16'
S.B.R./S.S.R. - 1498
va°
PVC GBEAD - 6064
CORNER CONSTRUCTION
�q
WINDOWSYSTEMS KO
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
CORNER WELD
8200 PVC
(ALL SIDES)
1:8
I15
6
R:
FIXED MEETING RAIL
SCREWED TOGETHER WITH
OUTERFRAME
1:8
s'6"�
/16-
i—
SASHSASH
REINF.-1699
7/16" 1j;1 1/4"
34
1/16"
ROLLER TRACK -1776
I 7/8•�
T-
9/16" 31
1/16"
GLAZE BEAD - 1112
1/2" 1 1/8.1 3/8" � r�1
vL
1/16"6" a.j Ins"
PVC SCREEN CATCH - 6013 PVC ANTI -LIFT - 6005
5/16" 1 1/8" 1
39
1/16•
PVC SCREEN SUPPORT - 6014
HORZ. SLIDER
IMPACT
g Z 3 aZ3
F auto Qw00O
Z ZOOZ mk?w
u- Fw3ZZ0�m=
Z Z S M Q
O OHO �_�M
U 0001--ZaFrna.
�
Z O� �U-
Q -OZit-0u
M�OF�Fo—
in I�LXLww 0Uv
en
o LUPO W=,>-
It
F a 1,3a
`0 "pSIORE riirr��pi
Wr
No 58201 :�-A S
0
1 STATE OF ;<+/`
c
z�-
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
BOM AND EXTRUSIONS
ADE 10/10/13
VG #: REV.:
CWS -871 C
ALE: SHEET
1.2 30F5
121/2" MAX. O.
6"MAX. (TYP.)
6" MAX (TYP.)
17"
MAX. O.C.
(TYP.)
.
.
...
.
.
.
...
..
..
.
. .
..
..
.
•• • ••
04" MAX F*P.)
4" MAX (TYP.)
• 000 • .
• 5A1c.'o.c• •
(TYP.)
—
8" MAX. O.C. (TYP.)
I
1
I
I O
I
I
I
I
I
1
I
I
I v
I ^
I
ANCHOR LAYOUT - (FIN)
WINDOW SYSTEMS
ffl
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
EE NOTE 2 W W W.0 W S.CC
8200 PVC
INSTALLATION HORZ. SLIDER
ANCHOR (TYP.) IMPACT
NOTES:
1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD.
2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE
CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED.
3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 5.
4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST
BE PROTECTED TO PREVENT REACTION.
5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURERS INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM
SPECIFIED IN TABLE 1, SHEET 5.
6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE.
INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQURE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.
INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE.
7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD AND METAL.
8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE.
SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 5. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED.
9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS:
FMA/AAMA 100(FIN WINDOWS), FMA/AAMA200(FLANGEWINDOWS), FMANVDMA250(BOXWINDOWS),FMA/AAMA/WDMA300(EXTERIORDOORS)
S Z 3 QZ3:
F ❑ W O Q W Op
O Z0Z 0W3:M
LLL I- Lu
Z ZO=9Q
LL
O HO _v)(L
U U�HZaL..�a
5
Z p—�jU�
Q F?uwZOOco
L, U
�Q�QO�FFOZ
W Lu d'(A0WlnW
LL�a. O_ju>CL Zr
O WHA w=hy
a a w3:Wa
ORE W
P�•�CENS.G,Q.L
C� FL
'v No 58201'P
.a:= L
;K=
9 STATE OF :W'
z�
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
ANCHOR SCHEDULE AND
NOTES
ADE 1 10/10/13
CWS -871 C
ALE: SHEET
1:20 4 OF 5
.
.
...
.
.
.
...
SEETABLE I
WW
1/4" MAX SHIM
CWS.CCA34474
8200 PVC
HORZ. SLIDER
IMPACT
.
.
...
. .
.
.
.. .
TYPICAL HEAD ANCHORAGE • • MIN. E BEDA`ENT
• • • • SEE =A ISE 1• • • :F --SUBSTRATE•
• • • • BY OTHERS
MIN. EDGE DIST.• • • • 114" OA4S • I SEE TABLE 1
SEE TABLE 1 • • • • •
• •• • •
SUBSTRATE BY OTHERS
SEE TABLE 1 MIN. EDGE DIST.
MIN. EMBEDMENT o0 SEE TABLE 1
PERIMETER SEALANT SEE TABLE 1 • • • • • • • •
BY INSTALLER INSTALLATIC1V CHpR
INSIDE AND OUT SEE T✓hI•E 1 • • • • • •
SEALANT BEHIND O • • •
FLANGE BY INSTALLER 1/4" MAX. SHIM • • • • • •
INSTALLATION
SEE TABLE 1
1/4" MAX. SHIM
SEALANT BEHIND
FLANGE BY INSTALLER O
PERIMETER SEALANT MIN. EMBEDME
BYINSTALLER SEE TABLE t
IN AND OUT
SUBSTRATE BY OTHERS � r / z I�I
SEE TABLE 1 -i MIN. EDGE DIST.
/� SEE TABLE 1
LA VERTICAL SECTION
5 TYPICAL SILL ANCHORAGE
PERIMETER SEALANT
BY INSTALLER
INSIDE AND OUT
SEALANT BEHIND
FLANGE BY INS TALLER
�� HOR¢ONTAL SECTION
5 TYPICAL JAMB ANCHORAGE
PERIMETER SEALANT� \
BY INSTALLER
INSIDE AND OUT
HORIZONTAL SECTION
5 BOX FRAME INSTALLATION
HEAD AND SILL SIMILAR FOR BOX INSTALLATION
FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE,
UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED:
MIN. 1/4" FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED
INSIDE AND OUT, FULL PERIMETER, BY INSTALLER.
PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS
SHOWN FOR FLANGE WINDOWS.
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
INSTALLATION DETAILS I
ADE 10/10/13
✓G #: REV.:
CWS -871 C
ALE: SHEET
1:2 5 OF 5
WINDOW SYSTEMS L_—�1900
MIN. EDGE DIST.
SEE TABLE 1
SUBSTRATE
BY OTHERS
SW 44TH AVE.
SEETABLE I
WW
1/4" MAX SHIM
CWS.CCA34474
8200 PVC
HORZ. SLIDER
IMPACT
S ETABLEDMENT
g
z 3 ¢Z3
W
PERIMETER SEALANT
Z
W J O ¢ o W
BY INSTALLER
INSIDE AND OUT
W
Q
Z O Z
Q N 3 0 Of 3 m
INSTALLATION ANCHOR
Q~
Z
O
ZZ w o_
Z 2 m
�=0-M
SEE TABLE I
BEHIND
v
OF -O
O U) 1-- Z(L I— O G.
SEALANT
–
OO
FIN BY INSTALLER
Z
(0 � j U
�C1 HORIZONTAL SECTION
5
Q
-–Z LL 7 0 O LLZ
O H O_
TYPICAL FIN ANCHORAGE
HEAD AND SILL SIMILAR FOR FIN INSTALLATION
F
m g F I-
O > L)
W
Z(n Lu 0JfnF
CL co
O
WF0 wo>_
H Lu
a
a O3a.
%�``0111111118"
p1I)RE W ✓��4,
TL �
JQ9.•�CENg .'Q���i
L�9'
'tet No 59201
PERIMETER SEALANT� \
BY INSTALLER
INSIDE AND OUT
HORIZONTAL SECTION
5 BOX FRAME INSTALLATION
HEAD AND SILL SIMILAR FOR BOX INSTALLATION
FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE,
UP TO AND INCLUDING A BOX -FRAME APPLICATION IS ACCEPTABLE PROVIDED:
MIN. 1/4" FILLET OF CONSTRUCTION -GRADE ADHESIVE CAULK IS APPLIED
INSIDE AND OUT, FULL PERIMETER, BY INSTALLER.
PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS
SHOWN FOR FLANGE WINDOWS.
9/22/2017
LUCAS A. TURNER, P.E.
FL PE # 58201
1239 JABARA AVE.
NORTH PORT, FL 34288
PH. 941-380-1574
INSTALLATION DETAILS I
ADE 10/10/13
✓G #: REV.:
CWS -871 C
ALE: SHEET
1:2 5 OF 5
BCIS Home I Log In User Registration I Hot Topics Submit Surcharge I Stats & Facts Publications Contact Us I BCIS Site Map Links Search
Florida
4 ',; *.�' Product Approval
re ..rrt�aatt++tt ��yy�� � �°� USER: Public User
Produrt Annrnvrl Menu >
tarch > Annliratinn I ict > Application Detail
GS_ FL *
FL11103-R4
Application Type
Revision
Code Version
2017
Application Status
Approved
*Approved by DBPR. Approvals by DBPR
shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
n
Product Manufacturer
Custom Window Systems Inc.
' • • •
•
Address/Phone/Email
1900 SW 44th Avenue
• •
*000
•' •
Ocala, FL 34474
• • •
• •
•
(352) 368-6922 Ext 291
• • •
• •
i
jlathrop@cws.cc
• • •' • •
• i
• • • •
Authorized Signature
Jay Lathrop
• •' •
••••••
• •
• •
jlathrop@cws.cc
• 0000
• •' •
••••••
••••
•••••
Technical Representative
Jay Lathrop
• • • •
• • • •
�' • ;
Address/Phone/Email
1900 SW 44th Ave
•
'
Ocala, FL 34474
• ' •
(352) 368-6922 Ext 291
• • • •
lathro
] P@cws.cc
• •
•
•
• ••
• • • • • •
Quality Assurance Representative
Jay Lathrop
••
0069
Address/Phone/Email
1900 SW 44th Ave.
Ocala, FL 34474
(352) 368-6922 Ext 291
jlathrop@cws.cc
Category
Exterior Doors
Subcategory
Sliding Exterior Door Assemblies
Compliance Method
Certification Mark or Listing
Certification Agency Keystone Certifications, Inc.
Validated By Steven M. Urich, PE
R Validation Checklist - Hardcopy Received
Referenced Standard and Year (of Standard) Standard Year
AAMA/WDMA/CSA 101/I.S.2/A440-05 2005
ASTM E1886-05 2005
ASTM E1996-05 2005
TAS 201/202/203 1994
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Date Submitted 04/09/2019
Date Validated 04/11/2019
Date Pending FBC Approval
Date Approved 04/18/2019
EL R Model, Number or Name I Description
11103.1 SGD-8900 PVC Sliding Glass Door. I SGD-8900 PVC Sliding Glass Door.
Limits of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +60/-60
Other: Large Missile, DP = +/- 60 psf, Max. panel size 4'x
8'. Config. include OXXO, OXO, OX, XO. Glass complies to
ASTM E1300-04.
Certification Agency Certificate
FL11103 R4 C CAC CAR 138-1096.12df
FL11103 R4 C CAC CAR 138-1327.Ddf
FL11103 R4 C CAC CAR 738-1612.Ddf
FL11103 R4 C CAC CAR 138-537.odf
Quality Assurance Contract Expiration Date
05/29/2021
Installation Instructions
FL11103 R4 II CWS -298D (SGD-8900. IMP. HVHZ).odf
Verified By: Lucas A. Turner 58201
Created by Independent Third Party: Yes
Evaluation Reports
FL11103 R4 AE EvalReport298D.Ddf
Created by Independent Third Party: Yes
Back Next • • • • • •
•••••• ••••
• •
rnntarr llc phone, 8ef1-487-1A24 • • • • • •
The State of Florida is an AA/EEO employer. Qnvriehr Jnn7am Starve of Florida_ :: pdvary Statement :: Arrwccihility Stae•,w,•:: Refund &11lA •
•
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-recaFd4?eMuest, do not sena electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395.p rsuant to Sectiyyij 11
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with aR iea8 ess if they haW one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do ryot wis4 W supply a p•rweebaddress,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S. please
click hwre. •••••• •
Product Approval Accepts: • • • • •
ONEt M • • • • • •
Credit Card
Safe
TURNER
ENGINEERING &
CONSULTING, INC.
2428 Old Natchez Trace Trl.
Camden, TN 38320
Ph. 941-380-1574
FBPE C.O.A. #29779
Evaluation Report 298D
April 8, 2019
Product Description: Series 8900 PVC Sliding Glass Door, LM Impact, 4'x8' nominal panel size max.
with SG Interlayer, 4'x6'8" nominal panel size max. with PVB Interlayer
Manufacturer: Custom Window Systems, Inc. 1900 SW 44`h Ave, Ocala, FL 34474
Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC
Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 6`h
Edition (2017) Florida Building Code including the High Velocity Hurricane Zone. The product testing
standards performed are outlined below.
Technical Documentation:
%t�Nturtttrryr
T
0000
i
1)
This report, prepared by Lucas A. Turner, P.E., at 2428 Old Natchez Trc Trl, Qamden, TN' .... •
• • • • • •
2)
Approval drawing CWS -298D, signed and scaled by Lucas A. Turner, P.E. '..' ••
•�
3)
Test Reports NCTL-2i0=3956-1 and =1A, from National -Certified -Testing Labioralouies, Orhafitlt,
—
Lucas A. Turner, P.E.
FL, signed and sealed by Gerard J. Ferrara, P.E., and Test Report CWS-021-02-01:,01tom PRI '
:••••
FL PE #58201
Construction Materials Technologies, Tampa, FL, signed and sealed by ZachaX� lVariest, P.to• •
a. Testing Performed: TAS 201/202/203 1994, AAMA/WDMA/CSA 101•/M'.Z/A440�
�'••'
0000.
00.00 0000
2009, and ASTM F 1 986/1 996 2005 '
0000
0000..
4)
.. ..
Supplemental calculations to support CWS -298D, signed and sealed by Lucas A..Turner, P.E. •
•,
•
0000..
0000..
Installation: Units must be installed according to approval document CWS -298D. • • • • • •
0000
Limitations of Use: This product:
• May be used in up to 48 7/8" x 93 1/2" panel sizes (96" max. door height) with Glass Type A
(SG), and up to 48 7/8" x 77 1/2" panel sizes (80" max. door height) with Glass Type B (PVB),
with max. glass daylight sizes as shown in CWS -298D
• Achieves design pressures of +/-60 psf
• Is Large Missile Impact Resistant and does not require the use of shutters
• May be used in the High Velocity Hurricane Zone
• Glass Type A requires Kuraray (Dupont) SentryGlas Interlayer per Miami -Dade NOA #17-0808.02
• Glass Type B requires Kuraray (Dupont) PVB Interlayer per Miami -Dade NOA #17-1114.14
• Requires Quanex (Mikron) white rigid PVC framing per NOA #17-0206.10. I have evaluated the
material in this NOA and find that it complies with the requirements of the 6th Ed. (2017) Florida
Building Code for use in this product.
Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial
interest in Custom Window Systems or in any company manufacturing or distributing products for which
this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest
in any other entity involved in the testing or approval process of this product.
%t�Nturtttrryr
T
i
y �l • No 582€ 1 • � r
Lucas
R ~
4/8/2019
Turner
9 : ; �:
Lucas A. Turner, P.E.
2019-04-08
= `. srATE of ,= fir:
FL PE #58201
13:08+19:00
MA:
MA
HEI
SEE
SLIDING GLASS 000R•:IKf A- :T:•••: •:•
•• • • • • • •
• • • • • • • • • 000
TABLE OF CONTENTS
GENERAL NOTES & ELEVATIONS .....................1
SECTION VIEWS OXXO & GLAZING DETAIL.....2
SECTION VIEWS OXO & XO................................3
EXTRUSIONS & B.O.M.........................................4
ANCHOR SCHEDULE & NOTES ............................5
INSTALLATION DETAILS.....................................6
MA:
HEI
SEE
D
A A
`6J
191 1;8"
48 7/8" MAX UNIT WIDTH
MAX •
PANEL WIDTH
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO
41314"
GLASS
COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION AND
48 7/8"
�•
ly • •�II�
• • I •
UNIT
DLO
n n
X 96 x96
WWW.CWS.CC
41 3/4"
3HT
--
--
SLIDING GLASS
--
--
HART
+/-60 PSF
:UNIT
— DLO
—
I)
B
MAX PANEL
HEIGHT
SEE CHART
O
GLASSDLO
SEE CHART
X
p w 0 w o a
X
L`,
•• 0: •I
••• •!
• • • •I
•• • •
I
O
X
MAXUNIT
h w ?i Z
�
GLASS
Z
D
O
TABLE OF CONTENTS
GENERAL NOTES & ELEVATIONS .....................1
SECTION VIEWS OXXO & GLAZING DETAIL.....2
SECTION VIEWS OXO & XO................................3
EXTRUSIONS & B.O.M.........................................4
ANCHOR SCHEDULE & NOTES ............................5
INSTALLATION DETAILS.....................................6
MA:
HEI
SEE
D
A A
`6J
145 13116"
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO
MAX UNIT WIDTF
COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION AND
48 7/8"
IS RATED FOR IMPACT USE IN WIND ZONE 4 AND HIGH VELOCITY
MAX
HURRICANE ZONE (HVHZ) AREAS AS DEFINED IN ASTM E 1996 PER THE FBC.
PANEL WIDTH
n n
X 96 x96
WWW.CWS.CC
41 3/4"
-41314--
1314"GLASS
8900 PVC
GLASS
SLIDING GLASS
UNIT
GLASS
DLO
+/-60 PSF
:UNIT
— DLO
—
— —
HART
ASTM E -1300-04e01/09.
1-
p w 0 w o a
:;HART
E
O
X
MAXUNIT
h w ?i Z
�
GLASS
Z
D
O
X
O
MAX PANEL
HEIGHT
SEE
GLASS
DLO
SEE CHART
SEE HART
RFOIIIRFD.
CHART
L
I
7. ALL FRAMES ARE PROCESSED AND SCREWED TOGETHER. VENTS FULLY
It
F
g50w -�
It H > L) O
---C
TABLE OF CONTENTS
GENERAL NOTES & ELEVATIONS .....................1
SECTION VIEWS OXXO & GLAZING DETAIL.....2
SECTION VIEWS OXO & XO................................3
EXTRUSIONS & B.O.M.........................................4
ANCHOR SCHEDULE & NOTES ............................5
INSTALLATION DETAILS.....................................6
MA:
HEI
SEE
D
A A
`6J
GENERAL NOTES:
96'
MAX UNIT WIDTH
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO
48 7/8'
COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION AND
MAX
IS RATED FOR IMPACT USE IN WIND ZONE 4 AND HIGH VELOCITY
PANEL WDTH
HURRICANE ZONE (HVHZ) AREAS AS DEFINED IN ASTM E 1996 PER THE FBC.
OCALA, FLORIDA 34474
n n
X 96 x96
WWW.CWS.CC
41 3/4"
3. APPROVED CONFIGURATIONS: "OXXO", "OXO", "XO" "OX"
8900 PVC
GLASS
SLIDING GLASS
UNIT
DOOR - IMPACT
DLO
+/-60 PSF
'HT
LARGE MISSILE
IMPACT
INFILTRATION TEST PRESSURE, AND GLASS TABLES
J
HART
ASTM E -1300-04e01/09.
1-
p w 0 w o a
5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN THE
E
O
X
MAXUNIT
h w ?i Z
�
GLASS
Z
HEIGHT
CALCULATIONS.
OLD
L)O O ai 0 V a F u- a
yZ
SEE CHART
¢
SEE HART
RFOIIIRFD.
>
Q_ w W p 0 LL_
7. ALL FRAMES ARE PROCESSED AND SCREWED TOGETHER. VENTS FULLY
It
F
g50w -�
It H > L) O
WELDED.w
GENERAL NOTES:
I
MAX. PANEL SIZE
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO
WINDOW SYSTEMS IL�I�/I IIL�%J
COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION AND
IS RATED FOR IMPACT USE IN WIND ZONE 4 AND HIGH VELOCITY
1900 SW 44TH AVE.
HURRICANE ZONE (HVHZ) AREAS AS DEFINED IN ASTM E 1996 PER THE FBC.
OCALA, FLORIDA 34474
n n
X 96 x96
WWW.CWS.CC
2. GLAZING DETAIL: (SEE SHEET 2)
3. APPROVED CONFIGURATIONS: "OXXO", "OXO", "XO" "OX"
8900 PVC
4. DESIGN PRESSURES:
SLIDING GLASS
-NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS
DOOR - IMPACT
TABLES ASTM E -1300-04e01/09.
+/-60 PSF
-POSITIVE DESIGN LOADS BASED ON TESTED PRESSURE, WATER
LARGE MISSILE
IMPACT
INFILTRATION TEST PRESSURE, AND GLASS TABLES
J
�
ASTM E -1300-04e01/09.
1-
p w 0 w o a
5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN THE
w
?OK Z M
00
DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR INSTALLATION DETAIL
9
h w ?i Z
�
WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR
Z
z x 2 a = w O O
CALCULATIONS.
0
L)O O ai 0 V a F u- a
yZ
6. PRODUCTS APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT
¢
000 uj — Z) U -
RFOIIIRFD.
>
Q_ w W p 0 LL_
7. ALL FRAMES ARE PROCESSED AND SCREWED TOGETHER. VENTS FULLY
It
F
g50w -�
It H > L) O
WELDED.w
a
OprrU)pwinw
w J
0�
SERIES
8. /MODEL DESIGNATION: SGD 8900.
0
=a Ou~i
w F- O 0- x cr
9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING:
CL
3: 111
~ a W a
X=OPERABLE SASH, O=FIXED SASH.
11,
10. SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS.
`````,,��OR101",
`� g ; • C F N ••., G
•� SF Py.
11. EXTERNAL WEEP SLOT = 1/4) 1" LOCATED 4" FROM BOTH ENDS.
.` VP;
zl :- ••
No 58241 t�9
Lucas
Turner
2019-04-08
E 13:23+19:00
CONFIG. MAX. UNIT SIZE
I
MAX. PANEL SIZE
DESIGN PRESSURE
GLAZING
IMPACT RATING
RATING
TYPE (Sht.2)
n n
X 96 x96
` 48-7/8" x93-1/2"
LO 41-3/4" x 86-3/8"
+/-60 PSF
ARGE MISSIL
IMPACT
96�
A
OXXO 191-1/8"x96"
A
X 96 x 80
48-7/8" x 77-1/2"
IDLO 41-3/4" x 70-1/4"
+/-60 PSF
B
LARGE MISSILE
IMPACT
OXO 145-13/16' x 80'
B
OXXO 191-1/8" 80"
x
B
4/812019
LUCAS A. TURNER, P.E.
FL PE 9 58201
2428 Old Natchez Trace Trl
Camden. TN 38320
PH. 941-380-1574
GENERAL NOTES AND
ELEVATIONS
ADE 1 06/03/08
CWS -298 D
'GALE: SHEET
1.33.33 1 OF 6
. ••• • • • •••
1231 • 21 J • f2(b (2Zi • •
• � I
•
•
•
00
• • .. •
**C2#11: 7,:::** 000
SECTION BBo---
PAIR OF ANrHORS AT EACH
2 SPACING
NOTE:
INSTALLATION WITH NO SILL RISER ALLOWED ONLY WHERE
WATER INFILTRATION RESISTANCE IS NOT REQUIRED.
SECTION C -C
FIXED PANEL ATTACHMENT
QUANEX DURASEAL
IG SPACER
1' OVERALL
3116" TEMPERED
3'8" AIRSPACE
716" LAMINATED GLAS,
3116' ANNEALED GLASS
090 KURARAY SENTRY
GLASSINTERLAYER
3116" ANNEALED GLASS
1:1.33
LASS TYPE
XL EDGEING SPA
PURFECT GLAZE "H"
SIKAFLEX 552
I
13/16" GLASS BITE
V OVERALL
3116" TEMPERED
318" AIRSPACE
7/16" LAMINATED GLASS
3116" ANNEALED GLASS
105 KURARAY PVB
INTERLAYER
3/16" ANNEALED GLASS
1:1.33
GLASS TYPE B
_E "H"
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
8900 PVC
SLIDING GLASS
DOOR - IMPACT
z i:`cz3:
E
F wO wwob
z w 10
ow
w zpz w—?F
Z z=2awwoo
O OF-odQwF zG-FwcL
Z p 0-ZI.-Z1�
Q HZLL20OtLU
2SO�I-FO—
Z
w I It (f) w (/) w
z J
a
0) �
O wr0 wCOw>-
a M W L
,,�` pAORE W,
TG,���
VP5•�.CE Ng�.•�yy
v : No 58201 •: �'1
�90i STAIE OF
BITE �fZ
4/812019
LUCAS A. TURNER, P.E.
FL PE # 58201
2428 Old Natchez Trace Trl
Camden, TN 38320
PH. 941.380-1574
SHEET DESCRIPT ON:
SECTION VIEWS - OXXO
AND GLAZJNG DETAIL
DRAWN BY: DATE:
ADE 06/03/08
DWG REV.:
CWS -298 D
SCALE: SHEET
1:2.63 2 OF 6
SECTION D -D
SECTION E -E
NOTES;
1. ITEMS NOT SHOWN FOR CLARITY: 10, 26-32
2. VERTICAL SECTION CAN BE SEEN ON SHEET 2.
bm
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORDA 34474
WWW.CWS.CC
8900 PVC
SLIDING GLASS
DOOR - IMPACT
<
Z <Z3:
oWo W<Wod
Z
o
T82 Q�Mw-
a0�}OW!m
•
•
...
...........
Z
(A
Q u-zjU�
<
P=-�OOOLLZ
<50w -mo-
<
.
........:
Oln Wu)OJtnw
a
O WHA
w=SU)
�a
:
v :
No 59201
•
•
•
• •
•
•
•••
SECTION D -D
SECTION E -E
NOTES;
1. ITEMS NOT SHOWN FOR CLARITY: 10, 26-32
2. VERTICAL SECTION CAN BE SEEN ON SHEET 2.
bm
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORDA 34474
WWW.CWS.CC
8900 PVC
SLIDING GLASS
DOOR - IMPACT
<
Z <Z3:
oWo W<Wod
Z
o
T82 Q�Mw-
a0�}OW!m
u-
Z
F -W Z�-3:21
Z=M<WWOO
O
OmOd<mvfa
Z
Z
(A
Q u-zjU�
<
P=-�OOOLLZ
<50w -mo-
<
X2121 1}-Cn0
W
Oln Wu)OJtnw
a
O WHA
w=SU)
�a
v :
No 59201
STATE OF ;1V`U
0
11
s/ONA,�N,��.
zz
4/812019
LUCAS A. TURNER, P.E.
FLIP # 58201
2428 Old Natchez Trace Trl
Camden, IN
38320
941-380-1574
SECTION VIEWS - OXO
AND XO/OX
ADE 1 06/03/08
CWS -298 D
TALE: SHEET
1:2.63 3 OF 6
P-4218
39 1 P-3302
JEL TOP/BOTTOM RAIL, SGD
JEL SIDE RAIL, SGD
JEL, INTERLOCK, FIXED
JEL, INTERLOCK, OPERABLE
RLOCK, SNAP-ON
RAGAL, SGD.
.LER, TANDEM
IM SEALER, SM -5504
BLOCK, 85 DUR. 1/8" X 7/8"
4FLEX 552 OR PURFECT GLA,
TP., 0.270 X.187, BACK FINSE
;3/4" QUAD PHILIPS, TEK
x 2, HEXHEAD, TEK
I PLUG, 1/2" HOLE
X 1" HEX WASHER HEAD, TE
:K 8 HANDLE KR, PVC, SGD
KEEPER
RTISE LOCK
x 2, PAN HEAD PHIL, SMS
VFORCEMENT, ALUM., PANE
VFORCEMENT, ALUM., PANE
:D PANEL CLP
/ER, FIXED PANEL CLIP
515/1x'
VENDOR MATERIAL y
MIKRON PVC •— —•—r♦ • • • • '{ _ F-
MIKRON PVC • • • • q J 1
4)
KEYMARK PLUM h • • • • • 211/16"
MICRON PVC 17/8- 0 • • • • • • • • • 1/8" L
MICRON PVC 'o�1��Ej❑�� 1/8"
MIKRON PVC I�
MIKRON PVC • •
MIKRON PVC JIVC OU� FAME - 6041 • • • REINF. - 1993
• • •
MIKRON PVC • • • • • • • • • • • • •
• • •• • • ••• • ••
SULLIVAN STEEL • • 1'17/8 �i • • • • 1 M7I'—y 1 7/8" -
SCHNEE • • • •
RANK LOWE RUBBER 4
KA/HENKEL
ULTRAFAB 7• • • • * 5
FASTENAL ZINC • • • • • • •
FASTENAL JNC 3 9/18• • • • • • • g 9/36" 3 9/16"
M&M NYLON • • • • • •
FASTENAL JNC • • • • • • • • • • 1/8"
1MFSRIIRY STFFI .. 1/8'
1/8"
KEYMARKI PVC PNL INTERLOCK - 6060 PVC PNL LOCKSTILE - 6059 PVC PNL INTERLOCK - 6033
NUM, SGD, SILL KEYMARK ALUM 1/2 2" j--21/16"
TRAGAL, SGD KEYMARK PLUM
NUM KEYMARK PLUM e 25
61
SGD MIKRON PVC
MIKRON PVC
I MIKRON PVC 3 N16" 1/16" 31/16" 2 5/8"
MIKRON PVC 1/8"-1116"
MIKRON
1116"
MIKRON PVC MI
0.2" X 1.25" DUST PLUG ULTRAFAB
RESHOLD COVER (8900) KEYMARK PLUM —
1" X7.1" X0.7" DUST PLUG ULTRAFAB PVC INTERLOCK SNAP - 6061 FIXED PNL CLIP -4295 FIXED PNL COVER - 1597
0.330" X0.187" BACK FIN ULTRAFAB 2 11/16"
PVC ASTRAGAL - 6043
SULLIVAN PVC1/8"
1116,
518" 1/Z" -"I i J J35 1�� r
73!16"" ROLLER TRACK - 1930
,.-- 3/4" 1116"
— 28) 1
SILL THRESH COVER -1764
PVC SCREEN ADAPTOR - 6045
7/W�
—23/16--
1
3116'
FRAME CONSTRUCTION
-M
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
www.cws.cc
-4
8900 PVC
FRAME CORNERS
SCREWED TOGETHER
1:10
VENT CONSTRUCTION
VENTS FULLY WELDED
1:10
1 5/8"--{ c)
213/16
1 15/16"
118" 1116'
L
REINF. - 1775 HIGHRISE - 1737
2" —
3Z
1 314"
1/16"
L PVC WELD SUPPORT - 6046
43/8" i 311/2" U` -� 1HM
11/4" 30) 9115"
8.
L 1/16" 1 1116" 1 1/
PVC SCREEN CHANNEL - 6044 DVC TRACK FILLER - 6040 FIXED PNL SUPPORT - 1722
PVC SCREEN TRACK - 6C41
REINF. - 1726 NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063•T6 UNLESS OTHERWISE SPECIFIED. PVC GLAZING BEAD - 6037
SLIDING GLASS
DOOR - IMPACT
a
z � <Z3
Z
W-10<wI-1W
W
u-
ZOZ G_L-ZL-
F-w�ZOF�M2
Z
z=2awwp0
0
Z—O—ZFDN
4
OZOOZO 0
�- u--
X20
W
of
u�wo>owcnw
Cn
a
_ wy
_~�
cr
w
DREW
` JVPS•��GENgF GQy.
v .
No 58201 : 9
STATE OF :•�/�
:
'�iO�F'•. C opt 10 P� Nom
Z
4/8i2019
LUCAS A. TURNER, P.E.
FL PE # 58201
2428 Old Natchez Trace Trl
Camden, TN 38320
PH. 941-380-1574
BOM AND EXTRUSIONS I
ADE 1 06/03/08
1Gk: REV.:
CWS -298 D
ALE' SHEET
1:2 1 401`6
6" MAX. —
(TYP)
18" MAX O.C.
GLASS TYPE
13" MAX O.C.
GLASS TYPE
• • ••• • • ••• 8" (TYP)
(TMP).,..
(TYP)••,•.,..,. I • ••• a
• • •1. • •
-.-v �irrl I
ANCHOR SCHEDULE At
BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED.
NOTES
3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6.
4!8;2019
4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RES STANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE
LUCAS A. TURNER, P.E.
PROTECTED TO PREVENT REACTION.
FL PE # 58201
5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM
2428 Old Nathez Trace TO
Camden, TN 38320
SPECIFIED IN TABLE 1, SHEET 6.
PH. 941.380-1574
9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS
CWS -298
D
FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX'NINDOWS), FMA/AAMA/WDMA 300(EXTERIOR DOORS).
CALE:
• • • • • • • •
.
• •
•
5 OF 6
• . •
00 00
1
• • • • • • •
•
I
• • • • • • •
•
i
I I I
ANCHOR LAYOUT
NOTES:
cuoibm
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
WWW.CWS.CC
8900 PVC
SLIDING GLASS
DOOR - IMPACT
Q 3Q
H OWQ tow8O
u- H W Z H3:� 2
Z Z= m Q w W O O
O Ov1OQaFu~ia
(n Z
_ Z Q o-ZF-UN
Q F §z 22t-
w �SO�FFO-
Il Q0�aiow�w
of
u- (n
W QJ(nH
a
p uj 0 w=�>-
a a W�a
'ORE W
`VP�• O E N S�.• �Qti.�
v : No 58201 •t`r-P
o:iz-
STATE OF:�(4
1. INSTALL TWO ANCHORS AT EACH LOCATION. SILL ANCHOR SPACING SAME AS HEAD.
SHEET DESCRIPTON:
2. SHIM AS REQ'D AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 114". USE SHIMS WHERE SPACE GREATER THAN 1116" 13 PRESENT. LOAD BEARING SHIMS SHALL
ANCHOR SCHEDULE At
BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED.
NOTES
3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6.
4!8;2019
4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RES STANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE
LUCAS A. TURNER, P.E.
PROTECTED TO PREVENT REACTION.
FL PE # 58201
5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM
2428 Old Nathez Trace TO
Camden, TN 38320
SPECIFIED IN TABLE 1, SHEET 6.
PH. 941.380-1574
6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS
TO SOLID CONCRETE OR GROUT-FILLED.CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS
SHEET DESCRIPTON:
BETWEEN THE PRODUCT AND SUBSTRATE.
ANCHOR SCHEDULE At
NOTES
7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 2" FOR MASONRY, 1" FOR WOOD AND METAL.
DRAWN 9Y:
DATE-7-
ATE:8.
8.WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE.
ADE
06/03/08
SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLE 1, SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED.
DWG#
REV.:
9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS
CWS -298
D
FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX'NINDOWS), FMA/AAMA/WDMA 300(EXTERIOR DOORS).
CALE:
SHEET
1.20
5 OF 6
TYPICAL HEAD ANCHORAGE
USSTRATE TYPE
ANCHOR TYPE
MIN. EMBEDMENT MIN. EDGE DIST.
2 7/16" MIN. MIN. EDGE DIST. •
•
• • •
•
•
•
• • •
•
• •
• • •
•
SEE TABLE 1 • •
• •
• •
•
•
•
•
• •
• •
•
3/16" ITW TAPCON
1"
"
•
INTERIOR
•
•
•••
•
• •
•
•••
SUBSTRATE BY OTHERS
SEE TABLE 1
PERIMETER SEALANT
BYINSTALLER
INSIDE AND OUT
INSTALLATION ANCHOR
SEE TABLE 1
PERIMETER SEALANT
BY INSTALLER
INSIDE AND OUT
DO NOT CCVER
WEEP HOLES
SUBSTRATE BY OTHE
SEE TABLE 1
MIN. EMBEDMENT
SEE TABLE 1
• • • • • •
.......... . ..
-1/4"MAX. SISIM� •� • • ••• • ••
• •• • • ••• ••
1/4" MAX. SHIM
-+ MIN. EMBEDMENT
SEE TABLE 1
27/16" MIN.
•• • • • •• ••• ••
INTERIOR • ••••• •• • • • • • ��
• • • • •• ••
•� • • • • ••
•• e
\ • • • • • • • 41141,110 • • MIN. EDGE DIST.
SEALANT BETWEEN an SEE TABLE 1
\ SILL RISER AND FRAME i
Q BYINSTALLER I / L
PERIMETER SEALANT BY INSTALLER —'
INSIDE AND OUT
0 � SUBSTRATE BY OTHERS —�
� SEE TABLE 1
i
B HORIZONTAL SECTION
EMBEDMENT TYPICAL JAMB ANCHORAGE
SEE TABLE 1
SEALANT UNDER SCREW `" F--2 7:16" 1 -I MIN. EDGE DIST.
HEAD BY INSTALLER MN. SEE TABLE 1
A VERTICAL SECTION
6 TYPICAL SILL ANCHORAGE
TABLE I: APPROVED INSTALLATION FASTENERS
USSTRATE TYPE
ANCHOR TYPE
MIN. EMBEDMENT MIN. EDGE DIST.
12"
2.0 KSI MIN.)
3/16" RW TAPCON
1"
CONCRETE (2.85 K
-
V
HOLLOW OR GROUT -FILLED CMU (117 PCF MIN.)
3/16" ITW TAPCON
1"
"
HOLLOW
HOLLOW OR GROUT -FILLED CMU (ASTM C-90)
3/16" ELCO ULTRACON
1-1/4"
2-1/2"
MMAX. 8"
2X MIN. SOUTHERN PINE (G=0.55)
3/16" ITW TAPCON
1-3/8"
1"
-
2XMIN. SOUTHERN PINE (G=0.55)
#10 WOOD SCREW
1-3/8"
1"
16 GAUGE (D.060") MIN. STEEL STUD
#10-16 HILTI KWIK-FLEX OR INV
FULL THREAD
FIXED PANEL CLIP
(33 KSI YIELD MIN)
TEKS SELF -DRILLING SCREW
THRU 0.060"
7/16"
CLIP ANCHORS MUST
1/8" ALUM. (6063-T5 MIN.) OR
#10 GRADE 5 SELF -TAPPING /
FULL THREAD
BE LOCATED A MINIMUM
DISTANCE OF 3" AWAY
1/8" STEEL 133 KSI MIN.)
DRILLING SCREW
THRU 0.125"
7/16
FROM AN" MAIN FRAME
L
FIXED PANEL CLIP ANCHORS INTO:
ANCHOR.
CONCRETE (2.0 KSI MIN.) OR
3/16" ITW TAPCON
INSTALLATION
HOLLOW OR GROUT -FILLED CMU (117 PCF MIN.)
ANCHOR(TYP)
FIXED PANEL CLIP ANCHORS INTO:
FIXED PANEL CLIP DETAIL
CONCRETE (2.85 KSI MIN.) OR
3/16" ELCO ULTRACON
1-1/4"
2 -
HOLLOW OR GROUT -FILLED CMU (ASTM C-90)
NOTE: FIXED PANEL CLIP ANCHORS INTO WOOD
OR METAL SHALL FOLLOW THE ANCHOR TYPE, MIN.
EMBEDMENT AND MIN. EDGE DISTANCE LISTED IN TABLE 1.
4
INSTALLATION ANCHOR
SEE TABLE 1
TWO ANCHORS PER
FIXED CLIP THROUGH
PRE -DRILLED HOLES
1/4' MAX. SHIM
FIXED PANEL
MIN, EMBEDMENT
SEE TABLE 1
FIXED
PANEL
EDGE DIST.
SEE TABLE 1
C HORIZONTAL SECTION
� 6 / FIXED PANEL ANCHORAGE
(omobym-
We
WINDOW SYSTEMS
1900 SW 44TH AVE.
OCALA, FLORIDA 34474
W W W.CW S.CC
8900 PVC
SLIDING GLASS
DOOR - IMPACT
Q Z aZowo�
Z W J❑ < Wob
oz W
0 HWZ
ZOFW�2
Q 3
Z Zm2<m'OOO
O Z-OZZF7w
ZOOUtn �U-
F=Z ;RoOu-
<SOw-FO-
Z
W ODtrwOWfnW
LL D W J
a
R WFo w=m>-
M WSW
a a
%%
o`"olkE W �T'�,.
JVpy��Gg�
EN
No 58201 t 3
�0: STATE OF
4/812019
LUCAS A. TURNER, P.E.
FL PE1
58201
2428 Old Natchez Trace TH
Camden, TN 38320
PH. 941-380-1574
GENERAL NOTES AND
ELEVATIONS
ADE I 06/03/08
CWS -298 D
ALE: SHEET
1.2.67 6 OF 6