RF-19-2179Location Address Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date:.09/23/2019 Parcel Number 424 NE 103RD ST, Miami Shores, FL 33138 1132060170750 Contacts Permit No.: RF -09-19-2479 Permit Type: Roof Work Classi}icatiorr: Repair Roof Permit Status. Approved Expiration: 03/17/2020 OMAR HERRERA Owner HOME OWNER Contractor 424 NE 103RD ST, Miami Shores, FL 33138 HOME OWNER Mobile: 3057107071 Description: PAINTING ROOF WHITE TO WHITE Valuation: $ 500.0Inspection Requests: r2-4949 Total Sq Feet: 0.00 0 Fees Amount Application Fee - Other $50.00 CCF $0.60 DBPR Fee $3.75 DCA Fee $2.50 Education Surcharge $0.20 Notary Fee $5.00 Roofing Fee $200.00 Scanning Fee $9.00 Technology Fee $6.25 Total: $277.30 Payments Date Paid Amt Paid Total Fees $277.30 Credit Card 09/23/2019 $227.30 Credit Card 09/19/2019 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit 1 assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWN E- FIDAVIT: ify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws reg4leling construction and zonihg. Futhermore, I authorize the above named contractor to do the work stated. / Applicant / Contractor / Agent Date September 23, 2019 Page 2 of 2 o��a31►� Miami Shores Village RECEIVED SE 1 019 Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 $ Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 BUILDING Master Permit No. PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS �570�_ JOB ADDRESS: T� `f �� City: Miami Shores County: Miami Dade Zip: - 3� Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): >> -- Phone#:S-%0'it�/ Address: City: 11 C= State: Zip: �3��►% Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: J J � © /��� Phone# - -?./0- 3�o9% Address: City: State: Zip: Qualifier Name: Phone#: State Certification or Registration #: Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: <30 Value of Work for this Permit: $." Square/Linear Footage of Work: Type of Work: ❑ Addition❑ Alteration ❑ New Repair/Replace ElDemolition s❑ Description of Work: �&A/TZWC5 /cam i L Specify color of color til`u tile: Submittal Fee $ Q Permit Fee $ 95y. 00 CCF $ .0. L� 0 CO/CC $ Scanning Fee $ �. �� Radon Fee $ d. 50 DBPR $ 3 . *_4 S Notary $ 5.00 Technology Fee $ LD Training/Education Fee $ 'o• O�.0 Double Fee $ Structural Reviews $ (Revised02/24/2014) Bond $ TOTAL FEE NOW DUE $� 3() Bonding Company's Name (if applicable) Bonding Company's Address z: City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approv . s ection fee will be charged. Signature Signature E CONTRACTOR The foregoing instrument was acknowledged before me this 1C� + day of 20 ( C by L.'FS1tJoP�U�w o is personally known to me or who has produced -- (04 COIL 'as identification and who did take an oath. NOTARY PUBL Sign: Print: °•SINDIA ALVAREZ Seal: ; - -N, MY COMMISSION # GG 238273 Pa: EXPIRES: September 3, 2022 Bonded Thru Notary Public Underwriters ********************* The foregoing instrument was acknowledged before me this day of me or who has produced 20, by who is personally known to identification and who did take an oath. NOTARY PUBLIC: Sign: Print: as ******************************************* APPROVED BY f !7 Plans Examiner Zoning f -S4=w al Review Clerk (Revised02/24/2014) Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNER BUILDER DISCLOSURE STATEMENT NAME: 0141'A707 DATE: D5?'l9 ADDRESS: 7 � 5 /L/C— La_-� 5X- 3a/.3 Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have read and understood the following disclosure statement, which entitles me to work as my own contractor; I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one -family or two-family residence. You may also build or improve a commercial building at a cost of $25,000.00 or less (The new form states 75,000). The building must be for your own use and occupancy. It may not be built for sale or lease. If you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and with -holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, buildings codes and zoning regulations. Please read and initial each paragraph. 1. 1 understand that state law requires construction to be done by a licensed contractor and have applied for an owner -builder permit under an exemption from the law. The exemption specifies that 1, as the owner of the property listed, may act as my own contractor with certain restrictions even though I do not have a license. Initial 2. 1 understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. Initial 3. 1 understand that, as an owner builder, I am the responsible party of record on a permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that the contractor is required by law to be licensed in Florida and to list his or license numbers on permits and contracts. Initial 4. I understand that I may build or improve a one family or two-family residence or a farm outbuilding. I may also build or improve a commercial building if the costs do not exceed $75,000. The building or residence must be for my use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within 1 year after the construction is complete, the law will presume that I built or substantially improved it for sale or lease, which violates the exemption. Initial 5. 1 understand that, as the owner -builder, I must provide direct, onsite supervision of the construction. Initial . 6. 1 understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure that the persons whom I employ have the license required by law and by county or municipal ordinance. Initial__�('�� I understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner -builder permit that erroneously implies that the property owner is providing his or her own labor and materials. I, as an owner -builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner -builder and am aware of the limits of my insurance coverage for injuries to workers on my property. Initial S. I understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the work being done. Any person working on my building who is not licensed must work under my direct supervision and must be employed by me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act (FICA) and must provide workers compensation for the employee. I understand that my failure to follow these may subject to serious financial risk. Initial 9. 1 agree that, as the party legally and financially responsible for this proposed Construction activity, I will abide by all applicable laws and requirement that govern owner -builders as well as employers. I also understand that the Construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. Initial - 10. 1 understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service, the United States Small Business Administration, and the Florida Department of Revenues. I also understand that I may contact the Florida Construction Industry Licensing Board at 850.487.1395 or http://www.mvfloridalicense.com/dbpr/pro/cilb/index html Initial 11. 1 am aware of, and consent to; an owner -builder building permit applied for in my name and understands that I am the party legally and financially responsible for the proposed construction activity at the following address: Initial --ca 12. i agree to notify Miami Shores Village immediately of any additions, deletions, or changes to any of the information that I have provided on this disclosure. Initial Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of contractor may be in civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an individual or firm is injured while working on your property, you may be held liable for damages. If you obtain an owner -builder permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is properly licensed and the status of the contractor's workers compensation coverage. Before a building permit can be issued, this disclosure statement must be completed and signed by the property owner and returned to the local permitting agency responsible for issuing the permit. A copy of the property owner's driver license, the notarized signature of the property owner, or other type of verification acceptable to the local permitting agency is required when the permit is issued. Was acknowledged before me this day of M'20 LGl By 6M tZ. 1F�NAS�,T0 who was personally known to me or who has Produced as identification. NOY "� SINDIA ALVAREZ MY COMMISSION # GG 238273 p : EXPIRES: September 3, 2022 '••Foi> Ft° Bonded Thru Notary Public Undenvritr:, BUILDING REVIEW OVED TECHNICAL DATA SHEET Heni5 �� 887 Tropi-Cool° �' 100% Silicone White Roof Coating Typical Physical Properties Appearance Glossy white liquid Solar Reflectance per CRRC 0.88 initial and 0.83 Rapid Rating Solids Content by Volume 91%+/-3 Thermal Emittance per CRRC 0.88 initial and 0.88 Rapid Rating voc 10 g/I maximum Solar Reflectance Index (SRI) per CRRC 111 initial and 104 Rapid Rating Tensile Strength 275 psi minimum Permeability 4.6 nominal Elongation at Break 150% minimum Flash Point 140.9° F (60.9° C� • Durometer Hardness, Shore A 42 +/- 5 points Shelf Life (Unopened) • • • • • • 24 months000000 Tack -Free Time 1 to 2 hours Application Temperature (Ambient) • • • • •36•F to 120 ° F (21C to 49° C) • Cure Time 2to6hours • • •••••• • • • • • • • • Approvals and Certifications • • • • • • • • • • • • ; • • ENERGY STAR®certified • • ;•.•;. •••••• • Cool Roof Rating Council (CRRC) rated product: Product ID# 0620-0038 ; • • • : •. • •; • Meets the requirements of California Energy Commission (CEC) Title 24 Section 118(1)3 • • • : . • • • • • • Florida Product Approval: FL# 17412.1, 17431.3, and 17431.4 • • • • • Miami -Dade County Product Control Approved: NOA# 14-1217.01, 14-1217.02, and 14-1217.03 • UL Classified: Cements and coatings for roofing systems as to external fire exposure <74LM> • FM Approved: Subject to the conditions of approval as a roof coating when installed as described in the current edition of the FMRC approval guide. • Tested and certified by NSF International in accordance with NSF Protocol P151: Health Effects from Rainwater Catchment System Components • Meets or exceeds ASTM D7281 Standard Test Method for Determining Water Migration Resistance Through Roof Membranes. • Meets or exceeds ASTM D6694 Standard Specification for Liquid -Applied Silicone Coating Used in Spray Polyurethane Foam Roofing Systems. Description HENRY® 887 TROPI-COOL® 100% SILICONE WHITE ROOF COATING is a premium, 100% silicone, moisture -cure coating designed to reflect the sun's heat and UV rays as well as protect many types of roofs. While suitable for use in all climates, the 100% silicone chemistry is especially suited for extreme tropical environments, which are exposed to some of the hottest and wettest weather with intense UV exposure. It is specially designed to maintain maximum reflectivity of heat and UV rays as it ages. Its moisture -cure chemistry creates a very aggressive chemical bond with the roof, which allows for permanent ponding water resistance, extreme durability, and superior capabilities of sealing and protection. Features • 100% waterproof • Excellent adhesion and flexibility • Rain -safe in 15-mintues • Permanent ponding water resistant • 1 -coat application 4 Am • Superior UV resistance and weathering characteristics • Wide application temperature ra 12 • VOCcompliant— solvent -free (2° C to 49° C) • Mold and mildew resistant • Lifetime limited warranty • Chemically bonds with roof substrates as it cures • Saves energy by reflecting heat • Easv to aDDly by sorav, roller, or brush RECEIVED SE 18019 BY: Henry Company 999 N. Sepulveda Blvd., Ste. 800, EI Segundo, CA 90245 Technical Services - Phone: 800-486-1278 E-mail: techservices@henrv.com www.Henry.com Rev. Date: 04/06/2017 Henry® 887 TROPI-COOL®100% SILICONE WHITE ROOF COATING Product Size 1 GALLON, 5 GALLON, 55 GALLON Shelf Life Unopened, 24 months from date of manufacture when stored in a cool, dry, and shaded location. Usage Coating can be used on many different commercial or residential roof substrates to reflect the sun's heat and UV rays, as well as to help seal and protect the surface. It works well on low slope roofs and is suitable for pitched roofs. Acceptable roof types include: CLEAN: Before coating the roof, use a pressure washer or high pressure nozzle and water hose to wash the roof with a nori-fliNing detergent, such as TSP or TSP substitute. Use appropriate pressure and take caution not to inject water into the roof substrate during washing. In areas with stubborn dirt, grease, or other contaminants, use a stiff bristle brush or broom to scrub the areas clean with additional water and non - filming detergent. Treat algae or moss. The most effective method of cleaning algae and moss from a roof is with a 50:50 mix of laundry strength liquid chlorine bleach and water. Apply with a sprayer and allow the solution to dwell on the roof surface for 15 to 20 minutes, and then rinse thoroughly with low pressure water. Extended dwell times may be necessary, however, avoid letting the solution dry completely as this may. prevent complete rinsing. Take proper precautions to protect landscaping and surrounding areas from the chlorine bleach solution. Use appropriate personal protective equipment when working with chlorine bleach. In severe cases, it may take more than one bleach treatment to kill all of the moss. Give the roof a final rinse to ensure it is free of all detergent or anything else that could affect adhesion. Allow roof to dry completely before application. Using a leaf blower or broom, clear any remaining dust, dirt, debris, and foreign material that may prevent proper adhesion. Apply a test area of coating over the existing membrane to verify absence of bleed -through and proper adhesion to membrane prior to start of application. PREP: Repair defects, such as splits, cracks, blisters, deteriorated flashing, cracked metal edging, and any other defects affecting the watertightness of the roof. As a preventative measure, seal all roof penetrations, curbs, flashings, transition areas, areas where dissimilar materials intersect, and other areas that could leak with Henry® 884 Tropi-Cool® 100•A Silicone Roof Sealant or Henry® 885 Tropi-Cool® 100% Silicone Seam & Repair Roof Sealant. Ensure all roof drains and gutters are clean and clear, and cut back any vegetation that is growing above the roof which may cause debris to fall on the roof and clog drains and gutters in the future. On metal roofs, remove rust by wire brushing. MIXING: Coating may settle during storage. Mix well prior to and during use with a drill and mixing paddle. For 1 and 5 gallon pails, use a minimum 3" diameter mixing paddle or hand mix with a suitable paddle until consistent viscosity is achieved. In drums, use a minimum 6" diameter mixing paddle. RV, Trailer, and Mobile Home Roofs: Check the manufacturer's recommendations for walking on the roof. Park on a level surface. Ensure vehicle is turned off with the parking brake set. Secure keys to ensure someone else does not move the vehicle while you are on the roof. Henry Company 999 N. Sepulveda Blvd., Ste. 800, EI Segundo, CA 90245 Technical Services- Phone: 800-486-1278 E-mail: techservices@henry.com www.Henry.com Rev. Date: 04/06/2017 • • • Aged including Built Roofing : �; asphalt roofs— -Up (BUR) and Modified Bitumen (MB) • • • Aged single -ply and rubber roofs, including TPO, EPDM, PVC, and Hypalon® roofs : • • �. • Spray Polyurethane Foam (SPF) roofs • Metal roofs • • • • • • • Concrete roofs • • •. •. • • • Recoating previously coated roofs •••• • ••••• •••••• • •• ••••• • RV, trailer, and mobile home roofs • • . • .• .• ..•• .•...• • Not recommended over shingles of any kind. : •: �: •. • • . . •••... Application • • • • • • •.. CLEAN: Before coating the roof, use a pressure washer or high pressure nozzle and water hose to wash the roof with a nori-fliNing detergent, such as TSP or TSP substitute. Use appropriate pressure and take caution not to inject water into the roof substrate during washing. In areas with stubborn dirt, grease, or other contaminants, use a stiff bristle brush or broom to scrub the areas clean with additional water and non - filming detergent. Treat algae or moss. The most effective method of cleaning algae and moss from a roof is with a 50:50 mix of laundry strength liquid chlorine bleach and water. Apply with a sprayer and allow the solution to dwell on the roof surface for 15 to 20 minutes, and then rinse thoroughly with low pressure water. Extended dwell times may be necessary, however, avoid letting the solution dry completely as this may. prevent complete rinsing. Take proper precautions to protect landscaping and surrounding areas from the chlorine bleach solution. Use appropriate personal protective equipment when working with chlorine bleach. In severe cases, it may take more than one bleach treatment to kill all of the moss. Give the roof a final rinse to ensure it is free of all detergent or anything else that could affect adhesion. Allow roof to dry completely before application. Using a leaf blower or broom, clear any remaining dust, dirt, debris, and foreign material that may prevent proper adhesion. Apply a test area of coating over the existing membrane to verify absence of bleed -through and proper adhesion to membrane prior to start of application. PREP: Repair defects, such as splits, cracks, blisters, deteriorated flashing, cracked metal edging, and any other defects affecting the watertightness of the roof. As a preventative measure, seal all roof penetrations, curbs, flashings, transition areas, areas where dissimilar materials intersect, and other areas that could leak with Henry® 884 Tropi-Cool® 100•A Silicone Roof Sealant or Henry® 885 Tropi-Cool® 100% Silicone Seam & Repair Roof Sealant. Ensure all roof drains and gutters are clean and clear, and cut back any vegetation that is growing above the roof which may cause debris to fall on the roof and clog drains and gutters in the future. On metal roofs, remove rust by wire brushing. MIXING: Coating may settle during storage. Mix well prior to and during use with a drill and mixing paddle. For 1 and 5 gallon pails, use a minimum 3" diameter mixing paddle or hand mix with a suitable paddle until consistent viscosity is achieved. In drums, use a minimum 6" diameter mixing paddle. RV, Trailer, and Mobile Home Roofs: Check the manufacturer's recommendations for walking on the roof. Park on a level surface. Ensure vehicle is turned off with the parking brake set. Secure keys to ensure someone else does not move the vehicle while you are on the roof. Henry Company 999 N. Sepulveda Blvd., Ste. 800, EI Segundo, CA 90245 Technical Services- Phone: 800-486-1278 E-mail: techservices@henry.com www.Henry.com Rev. Date: 04/06/2017 Henry® 887 TROPI-COOL®100% SILICONE WHITE ROOF COATING APPLY: Coating should only be applied to a clean, dry, frost -free, and fully prepared roof substrate as described above. It may be applied with a 1/2" to 1" nap lint -free roller, brush, or commercial airless spray rig. Containers are packaged to keep latent moisture from prematurely starting the curing process. After opening the container, try to use it up as soon as possible. Keep containers covered and sealed at all times during use, when practical. If a skin forms in the container, simply remove the skin, mix the product, and use the rest. It should be applied in one coat smoothly and evenly over the entire roof surface, including parapet walls at a minimum 1.5 gallons per 100 square feet. Dry film thickness (DFT) should be a minimum of 22 mils. Coating must be evenly applied and pin-hole free. On steep -slopes, rough or aged surfaces, additional coats may be required to obtain a uniform, consistent thickness. Ensure coating is fully cured prior to additional coating installations. Cure times generally require a minimum of 2 to 6 hours depending on weather conditions. Complete additional coats within 48 hours. Waiting longer than 48 hours may require initial coat to have to be washed prior to application of additional coats. Apply subsequent coats perpendicular in fashion to the previous coat. For example, apply 1st coat north and south; apply 2nd coat east and west. Polyurethane foam should be coated within 24 hours of application. New concrete roofs must be allowed to cure for a minimum 28 days before coating. Commercial Airless Spray Rig: If spraying, a commercial airless spray rig capable of producing a minimum of 3500 psi at the spray gun tip is required. The pump should have a minimum of 3 gallons per minute output and be fed by a 5:1 transfer pump to prevent cavitation. Always use components rated for pump pressure. Hoses should be Buna-N jacketed for prevention of moisture contamination. nosoiehould hav%4 • • minimum I.D. of 3/4" and an adequate working pressure. The spray gun should be high pressure (5000 psa Atha reve%e-a,c�an spray tip•' having a minimum orifice of 0.030 and a 50° fan tip. Do not use hoses that have been used for acrylics because tba liners $bsl"rhoistura aRa:. initiate the silicone cure process. . • •:. • • „ • 0000•• 0000 • • • NSF PROTOCOL P151: Number of coats: 1-3. Maximum Field Use Dry Film Thickness (mils): 30 (maScjr41"015 per;&%f)0Recoat.Cy4e.. Time/Temperature: 24 hours at 100° F (38° C). Final Cure Time/Temperature: 48 hours at 100' F (38° C). ..0.0. 0 • • 0 •:0 0' • • 100% • •• •• 0 6000•• Please consult Henry® Product Support for any specific questions regarding the application of this product....... 0 0 • • • . • Coverage 0 0 0 00. ' 0 . • • 0 00 • •0600• Approximately 320 square feet per 5 gallon size pail (approximately 100 square feet per 1.5 gallons). Dry film thickne?s.(:)")'should be a minimum of 22 mils. Coverage varies depending on surface texture and porosity. Clean -Up Clean-up of tools and spray equipment containing uncured material may be accomplished by cleaning or flushing with VM&P Naphtha or mineral spirits. Spray Equipment: This product cures by reacting with moisture and should not be left in spray guns, pump equipment, and hoses for prolonged periods unless equipment contains moisture lock hoses, fittings, and seals. Equipment without these components will transmit sufficient moisture vapor to gradually form cured material on hose walls and at unsealed connections potentially causing an increase in operating pressure and material flow restriction. Precautions DO NOT THIN. Use extreme caution when applying and walking on silicone coated surfaces. Silicone coated surfaces are extremely slippery and can create a fall hazard resulting in death or injury. Keep away from food. Not recommended for application at temperatures below 35° F (2° C) or if rain is expected in less than 15 minutes of application. Lower temperatures and/or less humidity will typically result in slower cure times. When transporting, make sure the pail is secured and the lid is tight to prevent spills. Store in a cool, dry, and shaded location. Ensure lid is completely sealed. Henry Company 999 N. Sepulveda Blvd., Ste. 800, EI Segundo, CA 90245 Technical Services- Phone: 800-486-1278 E-mail: techservices@henrv.com www.Henry.com Rev. Date: 04/06/2017 Henry® 887 TROPI-COOL• 100% SILICONE WHITE ROOF COATING Causes skin irritation. Causes serious eye irritation. Suspected of damaging fertility or the unborn child. May cause respiratory irritation. Prevention: Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Wear protective gloves, protective clothing and eye protection. Wash thoroughly after handling. Avoid breathing vapors, mists and sprays. Use only outdoors or in a well -ventilated area. Response: IF EXPOSED OR CONCERNED: Get medical advice or attention. IF ON SKIN: Wash with plenty of soap and water. If skin irritation occurs; Get medical advice or attention. Take off contaminated clothing and wash it before reuse. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice or attention. IF INHALED: Remove person to fresh air and keep comfortable for breathing. Storage: Store in a well -ventilated place. Keep container tightly closed. Store locked up. • • • • • • 0000 0000•• `• ` ` Disposal: Dispose of contents/containers to an approved waste disposal plant. • : • • • • 000.00 0000 Soso% See safety data sheet for further details regarding the safe use of this product. *so*** • S • 00so0• 0000 • • • • KEEP OUT OF REACH OF CHILDREN. 0000` 0.000 0000•• • •• 0000• FOR EXTERIOR USE ONLY. '•�••' 00'00' 0000•. • 0000•• • • Limited Product Warrant ' ' Y • • • • 0,000• We, the manufacturer, warrant only that this product is free of defects, since many factors which affect ther(wl4obtain:d frpr this priciucl'; - such as weather, workmanship, equipment utilized and prior condition of the substrate - are all beyond our contrb6-}b%rtfore, Henry Company cannot guarantee results of the application of the coating including, but not limited to: appearance, watertightness, and suitability of the substrate. The substrate to be coated must be structurally sound and have reasonable life expectancy prior to being coated. We will replace at no charge any product proved to have a material defect during the life of the existing roof, provided it has been applied in accordance with our written directions for uses we recommended as suitable for this product. Proof of purchase must be provided. This warranty is void if the coating is coated over, patched, painted, or covered in any way with any product other than this coating or approved products. DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY: THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. MANUFACTURER SHALL HAVE NO LIABILITY OF ANY KIND BEYOND PRODUCT REPLACEMENT, INCLUDING FOR CONSEQUENTIAL, EXEMPLARY OR INCIDENTAL DAMAGES RESULTING FROM ANY DEFECTS OR ANY DELAYS CAUSED BY REPLACEMENT OR OTHERWISE. IF PURCHASER DOES NOT ACCEPT THESE TERMS OF HENRY'S LIMITED WARRANTY, PURCHASER MAY RETURN WITHIN 30 -DAYS OF PURCHASE ALL CONTAINERS OR PACKAGES OF PRODUCT PURCHASED FOR A FULL REFUND (PROVIDED THE CONTAINERS OR PACKAGING IS UNOPENED AND LESS SHIPPING CHARGES IF ANY). RETENTION OF PRODUCT BEYOND 30 -DAYS FROM PURCHASE, OR USE OF PRODUCT SHALL CONSTITUTE ACCEPTANCE OF HENRY'S LIMITED WARRANTY TERMS, CONDITIONS AND DISCLAIMERS. THIS LIMITED WARRANTY PROVIDES THE PURCHASER'S EXCLUSIVE REMEDY FOR ANY DEFECT IN THE PRODUCT. To the extent that any part of this LIMITED PRODUCT WARRANTY AND LIABILITY DISCLAIMER is determined unenforceable under the law of the place of purchase of the product, that part is severed and the remainder of these terms remain in full force and effect. To the extent permitted by law, the duration of any implied warranties is limited to the duration of Henry's express warranty. STATEMENT OF RESPONSIBILITY The technical and application information herein is based on the present state of our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability, or completeness either expressed or implied is given other than those required by law. The user is responsible for checking the suitability of products for their intended use. Data sheets are updated on a regular basis; it is the user's responsibility to obtain and to confirm the most recent version. Information contained in this data sheet may change without notice. Henry Company 999 N. Sepulveda Blvd., Ste. 800, EI Segundo, CA 90245 Technical Services - Phone: 800-486-1278 E-mail: techservices@henrv.com www.Henry.com Rev. Date: 04/06/2017 M IAM 1-DADE * MIAMI -DADS COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) .-,-ww.miamidade.2ov/econom Henry Company LLC 999 N. Sepulveda Boulevard, Suite 800 El Segundo, CA 90245 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Prodgct.Contro+Stetion togbv-• • used in Miami Dade County and other areas where allowed by the Authority Having Jurisdictlbn CAHJ)y •. • • 060..0 0000 0000.. This NOA shall not be valid after the expiration date stated below. The Miami -Dade Counj'PrMtltict Control SectiorC (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve th'e PiUt to h1Ye tdis product • or material tested for quality assurance purposes. If this product or material fails to perform in tete accepted manner, Me: manufacturer will incur the expense of such testing and the AHJ may immediately revoke, "RF or susp; ndthe us* of such product or material within their jurisdiction. RER reserves the right to revoke this mance, if it is • • determined by Miami -Dade County Product Control Section that this product or material fads fo dieet the requirements..;. 0000.. of the applicable building code. 6 This product is approved as described herein, and has been designed to comply with the Florida Huildin; (;ode : • • •: including the High Velocity Hurricane Zone of the Florida Building Code. •' • • DESCRIPTION: Henry Company Spray Polyurethane Foam Systems over Concrete Deck LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 10-0419.04 and consists of pages 1 through 4 The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 14-1217.01 Expiration Date: 03/03/21 Approval Date: 04/02/15 Page 1 of 4 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Spray Applied Polyurethane Roof System Materials: Polyurethane Dect Type Concrete Maximum Design Pressure -575 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Dimensions Specifications Product Description 3009-03 Spray 2.5 to 3.0 lbs./ft3 TAS 110 Polyurethane spray applied foam4W Polyurethane Foam density utilizes an HFC blQwingj gent irotended for roofing applicatitms. • • • • • HSS 535 Solvent -Free 1, 2, 5 and 55 ASTM D6694 A one component,"moi*tu*re-curing• Silicone Roof Coating gallon containers silicone rubber roof coating. • SmartRoof M Premium 1, 2, 5 and 55 ASTM D6694 A one component,•Mo+sture-cueing• • • 1 -Coat High Solids gallon containers silicone rubber rouirol ing. • • • • Silicone Roof Coating .. •• •••• Henry 887HS 1, 2, 5 and 55 ASTM D6694 A one component:moRstpIre-curing • Tropi-Coop 100% gallon containers silicone rubber roof co4ting. ; • • • • • Silicone White Roof • Coating — High Solids • Pro -Grade® Elite 988HS 1, 2, 5 and 55 ASTM D6694 A one component, moisture -curing 100% Silicone White gallon containers silicone rubber roof coating. Roof Coating — High Solids Henry 887HS 1, 2, 5 and 55 ASTM D6694 A one component, moisture -curing Tropi-Cool®100% gallon containers silicone rubber roof coating. Silicone Gray Roof Coating — High Solids Pro -Grade® Elite 988HS 1, 2, 5 and 55 ASTM D6694 A one component, moisture -curing 100% Silicone Gray gallon containers silicone rubber roof coating. Roof Coating — High Solids EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Radco RAD -4832 ASTM D1622 11/10/10 RAD -4864 ASTM D1622 01/03/11 Momentum Technologies, Inc. RX26H9A TAS 110 12/28/09 AX23G913 ASTM D6694 03/22/10 AX23G9A ASTM D6694 03/22/10 Underwriters Laboratories Inc. R19143 UL 790/ASTM E 108 08/05/09 Wingerter Laboratories MT109-0998 TAS 114-D 12/03/10 NOA No.: 14-1217.01 MIAMI•DADE COUNTY Expiration Date: 03/03/21 Approval Date: 04/02/15 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 3: Concrete Deck Description: 2500 psi structural concrete or concrete plank System Type A: Sprayed polyurethane foam applied directly to concrete deck and covered with specified Miami -Dade Approved roof coating. All General and System Limitations apply. Surface Preparation: Deck shall be primed if required; in accordance with Henry Company recommendations, and shall be free of loose dirt, grease, oil 9f08ftr contaminants prior to priming or foam application. RemoNre loose dirt oF'd�bris by use of compressed air, vacuum or brooming. No washigi' haft be p;rngitTed. Oil, grease, release agents or other contaminants shall be rg**-fid with proper • • cleaning solutions. .... •. ..... .... . ..... Primers shall be applied if required; in accordance with**eii•manufiacttrrer's ..:..' instructions. All primers must be thoroughly dry and ttired prior to: feam • • • • • • application. ':': . . . . ...... All joint openings in concrete decks that exceed 1/4 inc; sfmU be groute or �....� caulked. • ... Polyurethane Foam Application: The polyurethane foam shall be applied uniformly over the entire surface at the specified thickness in compliance with the requirements set forth in Roofing Application Standard RAS 109 but in no case shall it be less than I" thick. The sprayed polyurethane foam shall be feathered at the edges to produce a smooth transition. Protective Coating HSS 535 Solvent -Free Silicone Roof Coating, SmartRoofTM Premium 1 -Coat Application: High Solids Silicone Roof Coating, Henry 887HS Tropi-Cool® 100% Silicone (Choose One) White Roof Coating — High Solids, Pro -Grade 40 Elite 988HS 100% Silicone White Roof Coating — High Solids, Henry 887HS Tropi-Cool®100% Silicone Gray Roof Coating — High Solids or Pro -Grade a) Elite 988HS 100% Silicone Gray Roof Coating — High Solids shall be applied to achieve a minimum dry thickness of 15 mils. Polyurethane foam surface shall be free of moisture, dust, debris, oils, tars, grease or other materials that will as recommended by Henry Company impair adhesion of the protective coverings. Any damage or defects to the polyurethane foam surface shall be repaired prior to the coating application. The coating shall be applied the same day as the foam when possible. If more than 72 hours elapse prior to the application of the coatings, the polyurethane foam shall be inspected for UV degradation. Maximum Design Pressure: -575 psf. NOA No.: 14-1217.01 Expiration Date: 03/03/21 Approval Date: 04/02/15 Page 3 of 4 TABLE 1 AMBIENT HUMIDITY APPLICATION LIMITS SPRAYED POLYURETHANE FOAM 00600 90000 • ■ ♦ ' * Dei 40.5 45.5 50.5 55.5 60.5 65.5 70 73.5 77 79.5 82 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. Spray polyurethane foam shall not be sprayed when ambient temperature is within 5 degrees of the dew point. Ambient humidity applications limits shall be as listed in Table 1 herein. Contractor shall monitor and record environmental conditions in the Job Log in compliance with RAS 109. Job Log shall be maintained at the job site and accessible to The Building Official. 3. Flashings and waterproof coverings for expansion joints shall be of compatible materials and in accordance with Henry Company published literature. 4. Miscellaneous materials such as adhesives, elastomeric caulking compounds, metal, vents and drains shall be a composite part of the roof system and shall be compatible with the foam and coating. 5. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and the wind load requirements of applicable building code. 6. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). END OF THIS ACCEPTANCE 00!00• • • • 0000•• NOA No.: 14-1217.01 Expiration Date: 03/03/21 Approval Date: 04/02/15 Page 4 of 4 Henry Compa=Guideline Air Temp/ Humidity/ De 110 100 90 80 • 70 • • • • f ••• of • • • 60 • • If• 50 000.0. • 40 0000 • • 1••• • 0000 • 30 1 1 1 1 1 1 1 1 1 •00009 • .• • • • . 45 67 40.5 50 70 45.5 55 72 50.5 6Q 7:5 X5.5 AW 45 50 55 60 65 70 75 80 85 909 -0 5Hui -400 • 67 70 72 75 78 80 78 75 70 64 38 ;5Q' 87 Dew point and relative humidity forgiven dry bulb temperature. 00600 90000 • ■ ♦ ' * Dei 40.5 45.5 50.5 55.5 60.5 65.5 70 73.5 77 79.5 82 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. Spray polyurethane foam shall not be sprayed when ambient temperature is within 5 degrees of the dew point. Ambient humidity applications limits shall be as listed in Table 1 herein. Contractor shall monitor and record environmental conditions in the Job Log in compliance with RAS 109. Job Log shall be maintained at the job site and accessible to The Building Official. 3. Flashings and waterproof coverings for expansion joints shall be of compatible materials and in accordance with Henry Company published literature. 4. Miscellaneous materials such as adhesives, elastomeric caulking compounds, metal, vents and drains shall be a composite part of the roof system and shall be compatible with the foam and coating. 5. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and the wind load requirements of applicable building code. 6. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). END OF THIS ACCEPTANCE 00!00• • • • 0000•• NOA No.: 14-1217.01 Expiration Date: 03/03/21 Approval Date: 04/02/15 Page 4 of 4 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. Spray polyurethane foam shall not be sprayed when ambient temperature is within 5 degrees of the dew point. Ambient humidity applications limits shall be as listed in Table 1 herein. Contractor shall monitor and record environmental conditions in the Job Log in compliance with RAS 109. Job Log shall be maintained at the job site and accessible to The Building Official. 3. Flashings and waterproof coverings for expansion joints shall be of compatible materials and in accordance with Henry Company published literature. 4. Miscellaneous materials such as adhesives, elastomeric caulking compounds, metal, vents and drains shall be a composite part of the roof system and shall be compatible with the foam and coating. 5. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and the wind load requirements of applicable building code. 6. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). END OF THIS ACCEPTANCE 00!00• • • • 0000•• NOA No.: 14-1217.01 Expiration Date: 03/03/21 Approval Date: 04/02/15 Page 4 of 4 NIMM MIAMI•DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE+ OF ACCEPTANCE (NOA) www.miamidade.2ov/economy Henry Company LLC 999 N. Sepulveda Boulevard, Suite 800 El Segundo, CA 90245 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of cgnstrgction rltate, Wts. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Pfodi 4Contrpl Section to be used in Miami Dade County and other areas where allowed by the Authority Having JurisdkAip"FAHJ) o • : • • • foe*:* This NOA shall not be valid after the expiration date stated below. The Miami -Dade Count�Rroduct Control.Sectiork: (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve th&right to hnve this prodelo • • • or material tested for quality assurance purposes. If this product or material fails to perfornri%tf1e; ccepjec ftVner, th4 • • manufacturer will incur the expense of such testing and the AHJ may immediately revoke, Mbdlty, or susp2flQ the us0 of such product or material within their jurisdiction. RER reserves the right to revoke this acc411ice, if it is '. determined by Miami -Dade County Product Control Section that this product or material fails to tneet t16""remei ts• 0 • of the applicable building code.00. • • • • • • .. • • • • This product is approved as described herein, and has been designed to comply with the Florida BuildingggV including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Henry Company Spray Polyurethane Foam Systems over Steel Deck LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 10-11 l 2.09 and consists of pages I through 4. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 14-1217.02 Expiration Date: 03/03/21 Approval Date: 04/02/15 Page 1 of 4 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Spray Applied Polyurethane Roof System Materials: Polyurethane Deck Tyne Steel Maximum Design Pressure -397.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product 3009-03 Spray Polyurethane Foam HSS 535 Solvent -Free Silicone Roof Coating SmartRoof M Premium 1 -Coat High Solids Silicone Roof Coating Henry 887HS Tropi-Cool®100% Silicone White Roof Coating — High Solids Pro-Grade0 Elite 988HS 100% Silicone White Roof Coating — High Solids Henry 887HS Tropi-Cool®100% Silicone Gray Roof Coating —High Solids Pro -Grade® Elite 988HS 100% Silicone Gray Roof Coating — High Solids 1, 2, 5 and 55 ASTM D6694 A one component, moisture -curing gallon containers silicone rubber roof coating. 1, 2, 5 and 55 ASTM D6694 A one component, moisture -curing gallon containers silicone rubber roof coating. 1, 2, 5 and 55 ASTM D6694 A one component, moisture -curing gallon containers silicone rubber roof coating. EVIDENCE SUBMITTED: Test Agency Test Test Name/Report Dimensiods Specifications Product Description 2.5 to 3.0 lbs./ft3 TAS 110 Polyurethane spray applied foam 144t• density ASTM D1622 utilizes an HFC blUWy nghgent jnteV&d Momentum Technologies, Inc. RX26H9A for roofing applicatiw&%. %%.' 1, 2, 5 and 55 ASTM D6694 A one componentombf3ture-curing gallon containers 03/22/10 silicone rubber roQf6diting. :... :. 1, 2, 5 and 55 ASTM D6694 A one component,wNtpre-cu ing, gallon containers R19143 silicone rubber roQtCQattng. •.;.. • 1, 2, 5 and 55 ASTM D6694 A one component,•moisttire-cu=ip&:. gallon containers 12/03/10 silicone rubber roof coating. 1, 2, 5 and 55 ASTM D6694 A one component, moisture -curing gallon containers silicone rubber roof coating. 1, 2, 5 and 55 ASTM D6694 A one component, moisture -curing gallon containers silicone rubber roof coating. 1, 2, 5 and 55 ASTM D6694 A one component, moisture -curing gallon containers silicone rubber roof coating. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Radco RAD -4832 ASTM D1622 11/10/10 RAD -4864 ASTM D1622 01/03/11 Momentum Technologies, Inc. RX26H9A TAS 110 12/28/09 AX23G913 ASTM D6694 03/22/10 AX23G9A ASTM D6694 03/22/10 Underwriters Laboratories Inc. R19143 UL 790/ASTM E 108 08/05/09 Wingerter Laboratories MTI09-0998 TAS 114-D 12/03/10 NOA No.: 14-1217.02 Expiration Date: 03/03/21 Approval Date: 04/02/15 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 2: Steel Deck Description: Minimum 20 gage, 1.5" Type -13 Steel Deck System Type A: Sprayed polyurethane foam applied directly to steel deck and covered with specified Miami -Dade Approved roof coating. All General and System Limitations apply. Surface Preparation: Metal surfaces should be primed according to Henry Cpmpany and "ing ...... manufacturers' recommendations. Primer shall be thorouglaAy :�ured.prip; to application of foam. ...... .... ...... .fees. . e . For ferrous metal, remove loose rust and unsound primer frOrfi•s'1{pp-pried jrpn • and steel surfaces by scraping, wire brushing or sandblasting ' Prime according ".". to Henry Company and coating manufacturer's recommenaatians. toy *non- .. .. .esG ...... ferrous metals, clean and prime aluminum, copper and staiples�eel surfaces as •• recommended by Henry Company. • . . . . ...... ..Gess 000 Primers shall be applied in accordance with their manufaatt.�rer s instructions. • All primers must be thoroughly dry and cured prior to foam application. • • • • Polyurethane Foam Application: The polyurethane foam shall be applied uniformly over the entire surface at the specified thickness in compliance with the requirements set forth in Roofing Application Standard RAS 109 but in no case shall it be less than 1" thick. The sprayed polyurethane foam shall be feathered at the edges to produce a smooth transition. Protective Coating HSS 535 Solvent -Free Silicone Roof Coating, SmartRoof— Premium 1 -Coat Application: High Solids Silicone Roof Coating, Henry 887HS Tropi-Cool®100% Silicone (Choose One) White Roof Coating — High Solids, Pro -Grade® Elite 988HS 100% Silicone White Roof Coating — High Solids, Henry 887HS Tropi-Cool®100% Silicone Gray Roof Coating — High Solids or Pro -Grade® Elite 988HS 100% Silicone Gray Roof Coating — High Solids shall be applied to achieve a minimum dry thickness of 15 mils. Polyurethane foam surface shall be free of moisture, dust, debris, oils, tars, grease or other materials that will as recommended by Henry Company impair adhesion of the protective coverings. Any damage or defects to the polyurethane foam surface shall be repaired prior to the coating application. The coating shall be applied the same day as the foam when possible. If more than 72 hours elapse prior to the application of the coatings, the polyurethane foam shall be inspected for UV degradation. Maximum Design Pressure: -397.5 psf. NOA No.: 14-1217.02 Expiration Date: 03/03/21 Approval Date: 04/02/15 Page 3 of 4 TABLE 1 AMBIENT HUMIDITY APPLICATION LIMITS SPRAYED POLYURETHANE FOAM GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. Spray polyurethane foam shall not be sprayed when ambient temperature is within 5 degrees of the dew point. Ambient humidity applications limits shall be as listed in Table 1 herein. Contractor shall monitor and record environmental conditions in the Job Log in compliance with RAS 109. Job Log shall be maintained at the job site and accessible to The Building Official. 3. Flashings and waterproof coverings for expansion joints shall be of compatible materials and in accordance with Henry Company published literature. 4. Miscellaneous materials such as adhesives, elastomeric caulking compounds, metal, vents and drains shall be a composite part of the roof system and shall be compatible with the foam and coating. 5. All attachment and sizing of perimeter nailers, metal profile, and/or flas • .6666• • • 6666•• 6666•• 6666• • • •••9• • • 0666•• 00••.• •6009• r hing termination designs shall conform to Roofing Application Standard RAS 111 and the wind load requirements of applicable building code. 6. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). END OF THIS ACCEPTANCE NOA No.: 14-1217.02 Expiration Date: 03/03/21 Approval Date: 04/02/15 Page 4 of 4 45 67 40.5 50 Henry Company LLC 45.5 55 72 50.5 60 •6 55. . EAirTemp/ Humidity/ Dew point Guideline 55 60 65 70 110 80 85 90 •'�3; 100 ♦ Hui 67 70 72 75 78 80 78 75 70 64 58 5T** t Dei 40.5 45.5 50.5 55.5 60.5 65.5 70 73.5 100 79.59,P2: 8 90 80 70 .' 60 • • 50 66.66• ' • 40 • 6666.• 30 • • r9• 6666•• • •�• Dew point and relative humidity forgiven dry bulb temperature. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. Spray polyurethane foam shall not be sprayed when ambient temperature is within 5 degrees of the dew point. Ambient humidity applications limits shall be as listed in Table 1 herein. Contractor shall monitor and record environmental conditions in the Job Log in compliance with RAS 109. Job Log shall be maintained at the job site and accessible to The Building Official. 3. Flashings and waterproof coverings for expansion joints shall be of compatible materials and in accordance with Henry Company published literature. 4. Miscellaneous materials such as adhesives, elastomeric caulking compounds, metal, vents and drains shall be a composite part of the roof system and shall be compatible with the foam and coating. 5. All attachment and sizing of perimeter nailers, metal profile, and/or flas • .6666• • • 6666•• 6666•• 6666• • • •••9• • • 0666•• 00••.• •6009• r hing termination designs shall conform to Roofing Application Standard RAS 111 and the wind load requirements of applicable building code. 6. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). END OF THIS ACCEPTANCE NOA No.: 14-1217.02 Expiration Date: 03/03/21 Approval Date: 04/02/15 Page 4 of 4 45 67 40.5 50 70 45.5 55 72 50.5 60 •6 55. . f Airl 45 50 55 60 65 70 75 80 85 90 •'�3; 100 ♦ Hui 67 70 72 75 78 80 78 75 70 64 58 5T** t Dei 40.5 45.5 50.5 55.5 60.5 65.5 70 73.5 77 79.59,P2: 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. Spray polyurethane foam shall not be sprayed when ambient temperature is within 5 degrees of the dew point. Ambient humidity applications limits shall be as listed in Table 1 herein. Contractor shall monitor and record environmental conditions in the Job Log in compliance with RAS 109. Job Log shall be maintained at the job site and accessible to The Building Official. 3. Flashings and waterproof coverings for expansion joints shall be of compatible materials and in accordance with Henry Company published literature. 4. Miscellaneous materials such as adhesives, elastomeric caulking compounds, metal, vents and drains shall be a composite part of the roof system and shall be compatible with the foam and coating. 5. All attachment and sizing of perimeter nailers, metal profile, and/or flas • .6666• • • 6666•• 6666•• 6666• • • •••9• • • 0666•• 00••.• •6009• r hing termination designs shall conform to Roofing Application Standard RAS 111 and the wind load requirements of applicable building code. 6. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). END OF THIS ACCEPTANCE NOA No.: 14-1217.02 Expiration Date: 03/03/21 Approval Date: 04/02/15 Page 4 of 4 M IAM 1 -DADS MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Henry Company LLC 999 N. Sepulveda Boulevard, Suite 800 El Segundo, CA 90245 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction niate'rials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - 4odecsoControl Ve* tion to be • used in Miami Dade County and other areas where allowed by the Authority Having Jurisdic,�?(•AHJ)! •; • • • • • • •; • This NOA shall not be valid after the expiration date stated below. The Miami -Dade County�fgliuct CoJltrol Sectioi • • • • (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve t}le jigflt to 141telC115 prodjWY•• or material tested for quality assurance purposes. If this product or material fails to perfornii," w accepted manner, the;..' manufacturer will incur the expense of such testing and the AHJ may immediately revoke, ", or suspelad the use..... of such product or material within their jurisdiction. RER reserves the right to revoke this Ic•c Vince, if it is • determined by Miami -Dade County Product Control Section that this product or material frills to dleet tl%;q44remeAtS00'0 of the applicable building code. .'. :....: This product is approved as described herein, and has been designed to comply with the Florida Building God& • including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Henry Company Silicone Roof Coatings LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 14-0122.04 and consists of pages 1 through 3 The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 14-1217.03 Expiration Date: 02/21/18 Approval Date: 04/02/15 Page 1 of 3 ROOFING COMPONENT APPROVAL Category' Roofing Sub -Category: Cements, Coatings & Adhesives Materials: Silicone 0000 SCOPE: •••••• This approves "Henry Company Silicone Roof Coatings" as a roof maintenance coating, as'desctibed it t� "t4otice of Acceptance, designed to comply with the Florida Building Code, High Velocity Hurricanes Rorie. 0000.. . MANUFACTURING LOCATION: ' • • • 0000 1. LaGrange, OH. 0000.. EVIDENCE SUBMITTED: • 0000.. Test Agency Test Identifier Test Snecifica4on. Momentum Technologies, Inc. AX23G9A ASTM D 6694/ TT'Cs355B PHYSICAL PROPERTIES OF COMPONENTS 0000.. 0000 • • Date 0000.. • 0000.. 0000.. 0000. . . 0000. 000000 0000.. .0.6/21/11••••: 0000 Trade names: HSS 535 SOLVENT -FREE SILICONE COATING, SMARTROOFn PREMIUM 1 -COAT HIGH SOLIDS SILICONE ROOF COATING, HENRY 887HS TROPI-COOL® 100% SILICONE WHITE ROOF COATING - HIGH SOLIDS, PRO -GRADE® ELITE 988HS 100% SILICONE WHITE ROOF COATING - HIGH SOLIDS, HENRY 887HS TROPI-COOL® 100% SILICONE GRAY ROOF COATING - HIGH SOLIDS, PRO -GRADE® ELITE 988HS 100% SILICONE GRAY ROOF COATING - HIGH SOLIDS Application Rate: See approved scope of use below. Specifications: ASTM D 6694 Description: A one component, moisture curing silicone rubber roof coating used at an application rate of, • Aluminum: Prime surface with Pro -Grade® Elite 211 Primer or Henry® Tropi-Cool® Roof Primer at 500 ft2/gal; Apply coating at minimum 2 gal/100ft2. • Concrete: Prime surface with Pro -Grade® Elite 211 Primer or Henry® Tropi-Cool® Roof Primer at 500 ft2/gal; Apply coating at minimum 2.5 gal/100ft2. • Coated Steel: Prime surface with Pro -Grade® Elite 211 Primer or Henry® Tropi-Cool® Roof Primer at 500 ft2/gal; Apply coating at minimum 2 gal/100ft2. • Galvanized Steel: Prime surface with Pro -Grade® Elite 211 Primer or Henry® Tropi- Cool® Roof Primer at 500 ft2/gal; Apply coating at minimum 2 gal/100ft2. • Granule Surfaced SBS: Prime surface with Pro -Grade® Elite 211 Primer or Henry® Tropi-Cool® Roof Primer at 500 ft2/gal; Apply coating at minimum 2.5 gal/100ft2. • PVC: Prime surface with Pro -Grade® Elite 211 Primer or Henry® Tropi-Cool® Roof Primer at 500 ft2/gal; Apply coating at minimum 2 gal/100ft2. • Smooth Surfaced BUR: Apply coating at minimum 2 gal/l00ft2. • EPDM: Apply coating at minimum 2 gal/ 100ft2. • Smooth Surfaced APP: Apply coating at minimum 2 gal/ 100ft2. Container Size: Primer available in: 1, 2, 5 gallon pails, 55 drums. Note all precautions on container. Coating available in: 1, 2, 5 gallon pails, 55 drums, 275 gallon totes. Note all precautions on container. Systems Approvals: Methods of application and quantities shall comply specific Roof Assembly, Product Control Notice of Acceptance. NOA No.: 14-1217.03 MIAMI•DADECOUNW Expiration Date: 02/21/18 IIS A U � �erigli Approval Date: 04/02/15 Page 2 of 3 LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire rating of this product. 2. Henry Company Silicone Roof Coatings shall not be applied in inclement weather conditions. 3. The products listed herein are components of roof assemblies and are approved for use wily roof a5sg>`rlies that .ee%* list any of the products listed herein as part of their roof assemblies Notice of Acceptaxod.: 900 • • 4. All products listed herein shall have an unannounced follow-up quality control program from an apjiWed listing • • • agency. Follow up test results shall be made available to Miami -Dade Product Control*.pon request. ;....; 5. Change in materials, use, or manufacture of any of the products listed herein shall be came for tAm"In ion of ..,., • this Notice of Acceptance ...... .. • • •.. .. .. 6. Henry Company Silicone Roof Coatings shall be applied in accordance with manufa�LWe.C'S published •.. ....... application instructions and as specified herein. ....• • .. 000 ?00 7. The use of a reinforcing fabric in a maintenance coating is only to enhance the coatin&�s ability to deliver :60 • • efficient and long term performance through the protection of the underlying roof system and in thissticulaf • use does not become a roof system itself , • • 8. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 9. All approved products listed herein shall be labeled in compliance with TAS 121 and shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. END OF THIS ACCEPTANCE NOA No.: 14-1217.03 Expiration Date: 02/21/18 Approval Date: 04/02/15 Page 3 of 3