RF-19-2117Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
i
Issue Date: 09/20/2019
Location Address Parcel Number
285 NE 100TH ST, Miami Shores, FL 33138 1132060134700
Contacts
Permit No.: EF -09-19-2117
Permit Type: Roof
Work Gtassificatiorr: Tile
Permit Status: Approved
Expiration: 03/18/2020
Description: RE -ROOF TILE Valuation: $ 25,500.00 Inspection Requests:
305-762-4049
Total Sq Feet: 4,000.00
Fees
William Wolk Owner
285 100
VOLTA ROOFING, INC Contractor
VIVIAN QUINONES
2329 SW 17 TER, MIAMI, FL 33145
Business: 7864223370 luis@voltaroofing.com
$50.00
CCF
$15.60
Description: RE -ROOF TILE Valuation: $ 25,500.00 Inspection Requests:
305-762-4049
Total Sq Feet: 4,000.00
Fees
Amount
Application Fee - Other
$50.00
CCF
$15.60
DBPR Fee
$4.88
DCA Fee
$3.25
Education Surcharge
$5.20
Roofing Fee
$275.00
Scanning Fee
$9.00
Technology Fee
$8.13
Total:
$371.06
Building Department Copy
Payments
Date Paid Amt Paid
Total Fees
$371.06
Credit Card
09/12/2019 $50.00
Credit Card
09/20/2019 $321.06
Amount Due:
$0.00
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
regulating constructioJ40 zoning. Futhermore, I authorize the above named contractor to do the work stated.
/ Applicant / Contractor / Agent Date
September 20, 2019 Page 2 of 2
Miami Shores Village c DYED
Building Department SEP 12 2019
10050 N.E.2nd Avenue, Miami Shores, Florida 33138 l ,
BY.
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
FBC 20
BUILDING Master Permit No. 6 r 09 -19 — 21 o
PERMIT APPLICATION Sub Permit No.
❑BUILDING ❑ ELECTRIC EdROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING [:]MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 285 /VE /0() ST
City: Miami Shores County: Miami Dade Zip: 1 3g
Folio/Parcel#: j I — 320(o 0)t Wi-00 Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): W (H (U h') LUO j iC_ Phone#:�
Address:g 1l(E 100 ST
City: i1 f fC S�Ofe-5 State: FL Zip: 3_513 6
.
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR: Company Name: L)ol 4. %�Phone#: 2-2- - 33
Address: 2232-9 Svw {-4 Te./Z r v
City: (a i rt4_ State: iz - Zip: 3 1d2) S
Qualifier Name: U101CLn C r1 ch Phone#:
State Certification or Registration #: 0-0-0. Q 300_ !E;lp Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address:
Value of Work for this Permit:
Type of Work: ❑ Addition
Description of Work:
City: State: Zip:
f � Square/LinearF�,000ttage of Work: LI,000 *a -T
ED Alteration ElE New Repair/Replace ❑ Demolition
Specify color of color thru tile: -Fe,nat !D -k
Submittal Fee $ D OpoidPermit Fee $ CCF $ CO/CC $
Scanning Fee $ Radon Fee $ DBPR $ Notary $
Technology Fee $ Training/Education Fee $
Structural Reviews $
Double Fee $
Bond $ ff> U o(I'D
TOTAL FEE NOW DUE $ U(0
(Revised02/24/2014) is 2-1 oG
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature 1���� G��T�� Signature
OWNER or AGENT
The foregoing instrument was acknowledged before me this
(.0 day of 20 PI by
LA)i W 0( )C— , who is personally known to
me or who has produced 4C ids 4u' 421 Coy/ IX, C as
identification and who did take an oath.
NOTARY PUBLIC:
Sign: eatr•aie°.
Print -
Seal:
Jose A. Giron
thru Aaron Notary
CONTRACTOR
The foregoing instrument was acknowledged before me this
_ day of 20 =l �W—�, by
lti w is personally =0\3,to
V ( a vt �C y1.C2 tom' ��
me or who hats produced as
identification and who did take an oath.
NOTARY PUBLIC:
Sign: a.
PY.P41,1
.�,,
Print:F
Seal:";"Qff
u��
Jose A. Giron
thru Aaron
2020
**rss:*.*******�***.***.*:*.ss*****s*s***sss*r**************r**************s********�****.*****.•**********
f'� .
APPROVED BY Plans Examiner Zoning
Structural Review
(Revised02/24/2014)
Clerk
<oR��
SECTION 1524
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with
the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402
govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the
following items should be addressed as part of the agreement between the owner ant the contractor. The owner's
initial in the designated space indicates that the item has been explained.
2..*'�Renafling wood decks: When replacing roofing, the existing wood roof deck may have to
be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually
concealed prior to removing the existing roof system).
4• Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking
can be viewed from below. The owner may wish to maintain the architectural appearance; therefore,
roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of
maintaining the appearance.
6. 'Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is
not overloaded from a buildup of water. Perimeter/edge wail or other roof extension may block this
discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow
scuppers in accordance with the requirements of Sections R4402, R4403 and R4413.
ef
Owner/Agents Signature D
,9;9,!r A19 /00y*&-
Property AddressAIW
,.>
Revised on 7/9/2009 LD;07/01/2015;
Contractor Signature Date
Permit Number
I
r
r
--x OF TO WA
i
Miami Shores
Villag(
Building Department
�-� 10050 N.E.2nd Avenuf
Miami'Shores, Florida 3313f
,Tel: (305) 795.2201
Fax: (305) 756.897
NNERS'S AFFIDAVIT OF EXEMPTION -
CONNECTION,"HURRICANE MITIGATION RETROFIT FOWEXISTING SITE.
BUILT SINGLE FAMILY RESIDENTIAL" STRUCTURES
PERSUANT.TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department
10050 NE 2n0Avt
Miami Shores, FI 33138'
Re:-, Owner's Name:1�«,.,� G
��. Date.:
rrvpefTy Haaress: z t 5 /V C7
Roofing Permit Number:
Dear Buifding Official:
�aie certify that I am not required to retrofit the roof to Wall connections of my
building tiecause:
9hevaluation for the --structure for purpose of ad valorem taxation pis less than $300,000.00. Please attach proof of ad
valorem taxation.
o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or, With the provisions
of 1994 edition of the South Florida Building Code (1994 SFBC)-
Signature .�
State of Florida
Print Name
County of Dade �.
The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned.
Sworn to and subscribed before me this Co Se- day of 2c�iir 1
q\
Jose A. Giron /
Notary Public, Sate of Florida at Large =" Commission # FF994930
u
�' Bonded thru Aaron Notary
• When the just valuation of the structure for °�1a
p rpose of ars ve 0 taxation is equal to or more than $3l ,000.00, and the budding was not constructed with FBC nor a 1994
SFBC. Then you must provide a budding application from a General Contractor for the Roof to Wan connection Hurricane Mitigation.
Revised on 5/21/2009
Property Search Application - Miami -Dade County Page 1 of 1
uFFICE OF THE PROPERTY APPRAISER
Summary Report
Property Information
Folio:
11-3206-013-4700
Property Address:
285 NE 100 ST
Miami Shores, FL 33138-2418
Owner
WILLIAM G WOLK
JULIET N WOLK
Mailing Address
285 NE 100 ST
MIAMI SHORES, FL 33138 USA
PA Primary Zone
1000 SGL FAMILY - 2101-2300 SQ
Primary Land Use
0101 RESIDENTIAL -SINGLE
FAMILY: 1 UNIT
Beds / Baths / Half
3/2/0
Floors
1
Living Units
1
Actual Area
Sq.Ft
Living Area
Sq.Ft
Adjusted Area
2,515 Sq.Ft
Lot Size
14,706.2 Sq. Ft
Year Built
1950
Assessment Information
Year
2019 2018
2017
Land Value
$441,362 $441,362
$441,362
Building Value
$215,347 $216,919
$218,491
XF Value
$23,045 $23,045
$23,045
Market Value
$679,754 $681,326
$682,898
Assessed Value
1 $538,378 $528,340
$517,474
Benefits Information
Benefit
Type
2019
2018
2017
Save Our Homes
Assessment
$50,000
$50,000
Taxable Value
$488,3781
$520,000
$141,376
$152,986
$165,424
Cap
Reduction
$25,000
Taxable Value
1 $513,378
Homestead
Exemption
$25,000
$25,000
$25,000
Second
$50,000
Taxable Value
$488,3781
$478,340
$467,474
Exemption
$25,000
$25,000
$25,000
Homestead
$488,378 $478,340
$467,474
Note: Not all benefits are applicable to all Taxable Values (i.e. County,
School Board, City, Regional).
IShort Legal Description I
MIAMI SHORES SEC 1 AMD PB 10-70
E1/2 OF LOT 21 & LOTS 22 & 23
BLK 34
LOT SIZE 127.880 X 115
COC 24740-2259 07 2006 1
Generated On : 9/12/2019
Taxable Value Information
2019
2018
2017
County
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$488,3781
$520,000
$467,474
School Board
Exemption Value
$25,000
$25,000
$25,000
Taxable Value
1 $513,378
$503,340
$492,474
City
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$488,3781
$478,340
$467,474
Regional
Exemption Value
$50,000 $50,000
$50,000
Taxable Value
$488,378 $478,340
$467,474
Sales Information
Previous Sale
Price
OR Book -Page
Qualification Description
03/20/2012
$720,000
28054-2560
Qual by exam of deed
04/14/2009
$520,000
26855-2863
Qual by exam of deed
L07/0L1/20O6
$875,000
24740-2259
Sales which are qualified
$390,000
21801-2681
Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http:/twww.miamidade.gov/info/disclaimer.asp
https://www8.miamidade.gov/Apps/PA/propertysearch/ 9/12/2019
Master Permit No
Contractor's Name
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section A (General Information)
Process No.
1
I
1
1
I
i
i
I
0000.. 1
•� I
0000.. 1
•000001
0000. 1
• •I0000.
0000..
.1
0000..
• •1
1
1
Section B (Roof Plan) I
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen-
sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1
t
i
1
1
1
1
I
1
1
t
Master
1 J
0000
Job Address `
Al 10c,�T
. .
• • • •
■
ROOF CATEGORY
0000..
•❑
0000
Low Slope
❑ Mechanically Fastened Tile
rMor;*tsive
Jy�s
❑ Asphaltic Shingles /
11 Metal Panel/Shingles
❑ Wooc��tE files/St 4es.
❑ Prescriptive BUR -RAS 150
00 000
• •
ROOF TYPE
❑ New roof ❑ Repair
❑ Maintenance Reroofing
0 ❑
Recovering
ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF)
Steep Sloped Roof AREA (SSF)—,1 X",Total (SF)�L�°
0000
1
I
1
1
I
i
i
I
0000.. 1
•� I
0000.. 1
•000001
0000. 1
• •I0000.
0000..
.1
0000..
• •1
1
1
Section B (Roof Plan) I
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen-
sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1
t
i
1
1
1
1
I
1
1
t
Master
■■■■■■�■
■■■■■■■■■■
■�
■
��...
MIN
�■��w
wed �\, ■
�1
��.■■i/���■_�
�
■,//._�_�. ■IIS■
■
�■
ME
�■ 1� � Iiiii rl■
■
�
�■
■�� 111 ■ 1
■■■®■■■
.
■
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.37
t 1 1 I Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8,201510:32:12 AM pursuant to License
Agreement. No further reproductions authorized.
Tile Roof System
MIAMIdaADE
EM Miami -Dade County HVHZ Electronic Roof Permit Form
Section D Tile Roof System
"Delivering Excellence Every Day"
Roof System Manufacturer: I SANTA FE CORP
Notice of Acceptance Number (NOA): 18-0604.04
Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations):
0000
•0000•
P1: 39.1 P2: 68.1 P3: 100.7 •..• ..
0000.. 0000
Maximum Design Wind Pressures, (From the NOA Specific system): 33.1 psf 000:0.
Fill in the specific roof assembly components. If a component is not required, insert not applicable {mis}in the to xt bow
0000
Roof Slope: 712"
Roof Mean Height: 14 ft.
Method of Tile Attachment:
--Adhesive, 2 Small Paddy Polyfoam Polypro—
Alternate Method of Tile Attachment per NOA:
NA
Drip Edge Size & Gauge: --3" face 26 ga.-
Drip Edge Material Type: I --Galvinized Metal -
Drip Edge Fastener Type: 1-1/4" RS NAIL 4"OC
Hook Strip/Cleat gauge or weight: I -- Select Hook Strip --
Deck Type:—5/S"PIyv�Totf'-•; ;' '.
0000..
Optional insulation:
. .
NA •
0000
Optional Nailable Substrate:
NA
Optional Nailable Substrate Attachment:
NA
Basesheet Type:
ASTM FELT D226 30#
Fastener Type for Basesheet Attachment:
1-1/4" RS NAIL & TIN CAP 1-5/8"
Tile Underlayment (Cap Sheet) Type:
POLYGLASS TU PLUS
Tile Underlayment Attachment Method:
SELF ADHESIVE
Tile Profile:
SPANISH "S" CLAY TILE
0 0 0 0. 0
0000..
0000..
0000.
0000.
0000..
0000..
0000..
Section E
MIAMPUNX
"Delivering Excellence Every Day"
Miami -Dade County HVHZ Electronic Roof Permit Form
Section E (Tile Calculations)
Method 1 "Moment Based Tile Calculations Per RAS 127"
For Moment based tile systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are
greater than or equal to the Mr values, for each area of the roof, then the the attachment method is acceptable. 09 0 •
. . . . ......
For Uplift based file systems use Method 3. Compare the values for F with the values for Fr. If the F values are greater than or equal �o tie Far values, for •
each area of the roof, then the tile attachment method is acceptable. • • • • • .00.
• : • • • •
0000
P1:=-I:===xw:===-W:===
Symbol
Where to Find
Design Pressure
P1 or P2 or P3
Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional
engineer based on ASCE 7.
• • 0000 0000••
P 1: 39.1
X a 0.297
= 11.61
�-
M ; 5.69
g 0
= Mr1: 5.92
5 33.1
0NAA.tO.
f ••�40 0
•••
P 2: =X
A 0.297
= 20.23
_ Mg; 5.69
= Mr2: 14.54
5 33.1
• 0.00:•
NOA Mf • : • • • •
P 3: 100.7
X a 0.297
= 29.91
_ Mg; 5.69
= Mr3: 24.22
5 33.1
• • 000..0
I�iA•11�f ";' •
Fr
Calculated
ht
E
W
Product Approval (NOA)
0000•• •• • 0000•
Method 3 "Uplift Based
Tile Calculations
Per RAS 127"
•• •• • •• 0000••
...... • •
. . . . ......
For Uplift based file systems use Method 3. Compare the values for F with the values for Fr. If the F values are greater than or equal �o tie Far values, for •
each area of the roof, then the tile attachment method is acceptable. • • • • • .00.
• : • • • •
0000
P1:=-I:===xw:===-W:===
Symbol
Where to Find
Design Pressure
P1 or P2 or P3
Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional
engineer based on ASCE 7.
Mean Roof Height
xcos0-==Fr1:=5=N0AF
Job Site
P2:=xl:===xw:===-W:===
0
Job Site
Aerodynamic Multiplier
X
Product Approval (NOA)
Restoring Moment due to Gravity
xcoso:a=Fr2:=5=N0AF'
Product Approval (NOA)
P3:=-I:===x1:===-W:===
Mf
Product Approval (NOA)
Required Moment Resistance
Mr
Calculated
ent Resistance
-c0s9:Q=Fr3:=5=N0AF
ProductApproval(NOA)
Where to Obtain Information to complete tile calculations
Description
Symbol
Where to Find
Design Pressure
P1 or P2 or P3
Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional
engineer based on ASCE 7.
Mean Roof Height
H
Job Site
Roof Slope
0
Job Site
Aerodynamic Multiplier
X
Product Approval (NOA)
Restoring Moment due to Gravity
Mg
Product Approval (NOA)
Attachment Resistance
Mf
Product Approval (NOA)
Required Moment Resistance
Mr
Calculated
ent Resistance
F
ProductApproval(NOA)
sistance
Fr
Calculated
ht
E
W
Product Approval (NOA)
I = length
w = width
Product Approval (NOA)
MI�AM�EI]ADE
11�8�i1 MIAMI -DADS COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www•.miamidade.eovleconomv
Santafe Tile Corporation
8825 NW 951h Street
Medley, FL 33178 ."
. . 0000
0000..
SCOPE: •• .".
'.
This NOA is beingissued under the applicable rules and regulations governing the use of c • • • * •ton materi ls. The
� PP 8u g g 4GS1MF,1;� a}
• • • • • •
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Prg" Controj Section to
; • • • •;
be used in Miami -Dade County and other areas where allowed by the Authority Having Jurl" tidn (AH:7•"•
0000.
000000
This NOA shall not be valid after the expiration date stated below. The Miami -Dade Countrvftooect Coir.(91.imtion
00:00'
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reservejae tigat to have this
• • • • •
• •
product or material tested for quality assurance purposes. If this product or material fails to••perforrt in th; accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediajely revoke, 8r
• •; •
•
suspend the use of such product or material within their jurisdiction. RER reserves the riglit,tp•ref oke this ..
; •' • %
acceptance, if it is determined by Miami -Dade County Product Control Section that this product or mateA44%99 to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Santafe Spanish `S' Clay Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be
done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 15-0915.09 and consists of pages 1 through 5.
The submitted documentation was reviewed by Freddy Semino a
NOA No.: 18-0604.04
Expiration Date: 02/01/21
Approval Date: 08/02/18
Page 1 of 5
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Test Identifier
Sub -Category: Roofing Tiles
Date
Material: Clay
94-156-8
Deck Tyne: Wood
Aug. 1994
• •
94-156-9
1. SCOPE •'• ••••
..
••••••
•�
This approves a roofing system using Santa Fe "Santafe `S" Clay Roof Tile, as manufac UTU by LadriHeo1W
....:.
Santafe S.A. in Bogota, Colombia and distributed by Santafe Tile Corporation as descnbed'ihsection 2 df thi'
March 1995
Notice of Acceptance. For locations where the pressure requirements, as determined by applicable SvUdipg
Project: 07-07-00-91
Code, do not exceed the design pressure values obtained by calculations in complianc ;wM*RAS 129 using the
• • o • •
values listed in section 4 herein. The attachment calculations shall be done as a moment* to *ed '.
60:600
system..
2. PRODUCT DESCRIPTION
'
Manufactured by Test I'Adud.
Dec. 1991
Applicant Dimensions Specifications Description •
0000
.. 0
....
Santafd `S' Clay Roof L = 18" TAS 112 One piece high profile clay roof tile equipped with
Tile W = 11. V Type I two nail holes. For nail -on, mortar set and adhesive
7161-03
Thickness = 0.39" Grade 1 set applications.
Dec. 1991
Trim Pieces I = varies TAS 112 Accessory trim, clay roof pieces for use at hips,
Appendix III
w = varies rakes, ridges and valley terminations. Manufactured
varying thickness for each the profile.
Redland Technologies
2.1 MANUFACTURING LOCATION
1. Bogota, Colombia
2.2 SUBMITTED EVIDENCE
Test Agency
Test Identifier
Test Name/Report
Date
The Center for Applied Engineering, Inc.
94-156-8
TAS 101
Aug. 1994
94-156-9
TAS 102
The Center for Applied Engineering, Inc.
25-7205-1
TAS 101
March 1995
The Center for Applied Engineering, Inc.
Project: 07-07-00-91
TAS 100
Sept. 1994
(307023)
Redland Technologies
7161-03
TAS 108
Dec. 1991
Appendix II
(Nail -On)
Redland Technologies
7161-03
Static Uplift Testing
Dec. 1991
Appendix III
TAS 102 & TAS 102(A)
Redland Technologies
P 0402
Withdrawal Resistance
Sept. 1993
Testing of Screw vs smooth
shank nails
Redland Technologies
P 0647-01
TAS 108
Aug. 1994
(Mortar Set)
MIAMMADE COUNTY
NOA No.: 18-0604.04
Expiration Date: 02/01/21
Approval Date: 08/02/18
Page 2 of 5
2.2 SUBMITTED EVIDENCE
Test Agency Test Identifier Test Name/Report Date
Redland Technologies P 063 1 -01 PA 108 July. 1994
(Mortar Set)
Celotex Corporation Testing Services 520305-01 thru 05 PA 102 Jufte l929
IBA Consultants, Inc. 2353-4 Restoring Momani' 4
ug.•1,999
PRI Asphalt Technologies, Inc. SFTC-003-02-01 TAS 101 ... • • 19;W82
IBA Consultants, Inc. 2353-70 TAS 101 • + • • • 09/12/03
IBA Consultants, Inc. 2353-71 TAS 101 • • • • + • :(i�/i2/03
IBA Consultants, Inc. 2353-93 ASTM C 117 • •:MT 19405
American Test Lab of South Florida RT0624.01-15 ASTM C1163.09... •07/91115
PRI Construction Material Technologies COPO-002-02-08 TAS 101! • .10112116
3. .. . ..
LIMITATIONS •
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly tesl
in accordance with TAS 112, appendix W. Such testing shall be submitted to the Miami -Dade Count)
Product Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless statec
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 May be installed on slopes 7:12 and greater.
4. INSTALLATION
4.1 Santafe 'S' and its components shall be installed in strict compliance with Roofing Application Standard
RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
NOA No.: t8-0604.04
Expiration Date: 02/01/21
Approval Date: 08/02/18
Page 3 of 5
Table 1: Average Weight (W) and Dimensions (I x w)
Tile Profile Weight -W (Ibf)
Length-1(ft)
Width -w (ft)
Santafe 'S' 6.7
1.5
0.958
Table 2: Aerodynamic Multipliers— %(W)
Tile
Profile
% (ft')
Batten Application
(ft)
Direct Deck
Santafe 'S'
0.274
0.297
• '•
Table 3: Restoring Moments due to Gravity - Mg (ft.-Ibf)• 0
• 0000
Tile
2":12"
36#12" 4"•12"
6'"12"
6"•42' •
•7'12" or
Profile
NIA
One #8 Screw 29.161.2
IVA.
• • • • • •
• eater
One #8 Screw wl Clip 57.311.2
Battens
Direct
Battens Direct Battens
DirectBattens
Direct
Battens Uiiect
Battens
Direct
Deck
Deck
Deck
Deck
• .Qeck
Deck
Santafe'S'
5.93
5.90
5.85 5.82 5.73
5.69
5.56
5.53
5.3 .29
pay•
5.00
00.0.0 00 0
Table 4: Attachment Resistance Expressed as a Moment - MP(ft.•Ilb
for Nail -On Systems • • • • • •
.. •
•
Tile Profile
Fastener Type
Direct Deck
•Sat;teas
Santafe 'S'
2-10d Ring Shank Nails
21.8
NIA
One #8 Screw 29.161.2
IVA.
Two #8 Screws 38.28'
NTA
One #8 Screw wl Clip 57.311.2
N/A
Two #8 Screws w/ Clip 57.60'
61.771
1. Approved screws as noted'Product manufactured by others'.
2. When using one screw it must be Installed in the inside hole located nearest to the hump of the tile.
00.00
•
Table 5: Attachment Resistance Expressed as a Moment Mf (ft.-Ibf)
for Two Patty Adhesive Set Systems
Tile Profile
Tile Application 2 Minimum Attachment Resistance
Santafe 'S'
Tile Bond 38.93
Pol oam Polypro AH 160Tm 33.1 4
2 See manufactures component approval for installation requirements.
3 Flexible Product, Inc. Average weight pera 10.4 grams.
4 Polyfoam Product Inc. Average weight pera 9.4 grams.
Table SA: Attachment Resistance Expressed as a Moment - Mf (ft.-Ibf)
for Single Patty Adhesive Set Systems
Tile Profile
Tile Application 2 Minimum Attachment Resistance
Santafe 'S'
Polyfoam Polypro AH 1601m 66.55
Poiyfoarn Polypro AH 160Tm 63.86
DAP Foam Touch N Seal Storm Bond 2 1007
5 Paddy placement of 63
grams of Polypro AH 160M.
6 Paddy placement of 24
grams of Polypro, AH 160TM.
7 Paddy placement of 45
grams DAP Foam Touch N Seal Storm Bond 2
NOA No.: 18-0604.04
MIAMIDADECOUPM Expiration Date: 02/01/21
Approval Date: 08/02/18
Page 4 of 5
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Mortar or Adhesive Set Systems
Tile Profile Tile Application Attachment Resistance
Santafe 'S' Mortar Set 23.6
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below,
or following statement: "Miami -Dade County Product Control Approved".
SANTA FE TM MADE IN COLOMBIA .••••.
....
LABEL FOR SANTA FE SPANISH "S" CLAY ROOF TILE • • • • • • '.; • • •
•
9.9.99
6. BUILDING PERMIT REQUIREMENTS • • • •
6.1 Application for building permit shall be accompanied by copies of the following:0 •
6.1.1 This Notice of Acceptance. 0*0000
6.1.2 Any other documents required by the Building Official or applicable bu "Q& pode in ordgr to
properly evaluate the installation of this system. • ; 9 •
.9060•
0*6
PROFILE DRAWING 0 • • •
>_1
06:009
When using one screw
.e this hole.
"SANTAFE S" CLAY ROOF TILE
END OF THIS ACCEPTANCE
•
9999••
•
NOA No.: 18-0604.04
MU4MFDADECOUN7Y Expiration Date: 02/01/21
Approval Date: 08/02/18
Page 5 of 5
T71
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.¢ov/economv
ICP Adhesives and Sealants, Inc.
12505 NW 44`c Street
Coral Springs, FL. 33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section.to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). • • • • • •
• 9999
This NOA shall not be valid after the expiration date stated below. The Miami -Dade Count? Ooduct Contrpl Section : -
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve thtori:f hto have $hic produrt0 0 0: •
or material tested for quality assurance purposes. If this product or material fails to perform i fWfflccepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, a ec%, or s>;VW4�the use • •':
of such product or material within theirjurisdiction. RER reserves the right to revoke tits acceptance, if it tsr: • • •
determined by Miami -Dade County Product Control Section that this product or material faj�$ % peet the res izementS • 0
of the applicable building code. • 0 • • 0 •
990909
09
This product is approved as described herein, and has been designed to comply with the Flarida rj4Ldjng Codo00:*
including the High Velocity Hurricane Zone of the Florida Building Code. 0 .
.. 9999..
9999
DESCRIPTION: ICP Adhesives Polyset® AH -160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
e0W
MIAMMADE COUNTY
�nl...t�
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 1 of 11
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset' AH -160 as manufactured by ICP Adhesives and Sealants, Inc. as described
in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP
Adhesives Polyset® AH -160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test
Specifications
ICP Adhesives
Polyset®AH-160
ICP Adhesives Foam
Dispenser RTF1000
ICP Adhesives ProPack®
30 & 100
N/A TAS 101
Product Bescription ' •
••
Two component poly 0 0 . foam'gd'hesive• • • • •
N/A Dispensing Equipment • • • •
N/A Dispensing Equipment•.....
•
00 0
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset® AH -160 roof tile adhesive.
MANUFACTURING LOCATION:
Tomball, TX.
PHYSICAL PROPERTIES:
Prope
Test
Results
Density
ASTM D 1622
1.61bs./ft.'
Compressive Strength
ASTM D 1621
18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength
ASTM D 1623
28 PSI Parallel to rise
Water Absorption
ASTM D 2127
0.08 Lbs./Ft2
Moisture Vapor Transmission
ASTM E 96
3.1 Perm / Inch
Dimensional Stability
ASTM D 2126
+0.07% Volume Change @ -40' F., 2 weeks
+6.0% Volume Change @158°F., 100% Humidity, 2
weeks
Closed Cell Content
ASTM D 2856
86%
Note: The physical properties listed
above are presented as typical average values as determined by
accepted ASTM test methods
and are subject to normal manufacturing variation.
No.: 17-0322.03
CAMNOA
DADecouNTY
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2 of 11
EVIDENCE SUBMITTED:
Test Azency
Center for Applied Engineering
Miles Laboratories
Polymers Division
Ramtech Laboratories, Inc.
Southwest Research Institute
Trinity Engineering
Celotex Corp. Testing Services
Test Identifier
#94-060
257818 -IPA
25-7438-3
25-7438-4
25-7438-7
25-7492
NB -589-631
9637-92
01-6743-011
01-6739-062b[l]
7050.02.96-1
P36700.04.12
P39740.02.12
528454-2-1
528454-9-1
528454-10-1
520109-1
520109-2
520109-3
520109-6
520109-7
520191-1
520109-2-1
Test Name/Report
TAS 101
TAS 101
SSTD 11-93
SSTD 11-93
SSTD 11-93
ASTM D 1623
ASTM E 108
ASTM E 108
'..' •:
ASTM E 84
•••••.
0000..
TAS 114
."•'•
ASTM D 1623
TAS 101
•��••:
TAS 123
••�•••
TAS 101
TAS 101
TAS 101
Date
04/08/94
12/16/96
10/25/95
11/02/95
12/12/95
02/01/94
04/30/93
0000
111a 6%94
01Aggi '
03f14/96
00.00.
04118/ 12
02121/ 12,
1 Q/2Sf98
0000
12/28/98
03/02/99
0000..
0000..
0000..
0000.
0000.
0000..
0000..
0000..
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset' AH -160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset' AH -160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 17-0322.03
MIAMI -DAD, COUNTY Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
INSTALLATION:
1. ICP Adhesives Polyset' AH -160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH -160.
2. ICP Adhesives Polyset® AH -160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH -160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset® AH -160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
'16009"
5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is requtrea before appUlg,ation
• • �'
of any adhesive. The mix ratio between the "A" component and the "B" component shal? belnaintained2r0een
1.0-1.15 (A): 1.0 (B). 0.0000
•
6. ICP Adhesives Polyset® AH -160 shall be applied with ICP Adhesives Foam Dispenser Itli;060 or ISA•:.
' ��•••
Adhesives ProPack® 30 & 100 dispensing equipment only. •.Y... ••
0000.
.
• •.
7. ICP Adhesives Polyset® AH -160 shall not be exposed permanently to sunlight. •' • •
0000.
• •0000
0000..
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minute; after ICP Adhesiyes
�.
0000..
Polyset® AH -160 has been dispensed. : . • .
0000..
.
9. ICP Adhesives Polyset® AH -160 placement and minimum patty weight shall be in accordance. with lie.".
0000. •.
'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. 0000
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Minimum Paddy Contact -
Minimum Paddy Gram
Area
Weight
Eave Course - Flat, Low, High
All Eave Course
17-23 sq. inches
45-65
Profiles
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches
30
Low Profile
#2
12-14 sq. inches
30
High Profile
#2
17-19 sq. inches
30
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at
12 grams per paddy
head of tile 9-11 sq. inches at
overlap
669699
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal
' • 17gramsr or b ead
edge) 20-25 sq. inches each
•""'
bead
•
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
••3� grams -under pan
V0
LABELING: •
...... ......
All approved products listed herein shall be labeled and shall bear the imprint or identifiable n4gr�ing of the ; • • • •
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" o; tV Miami- • •
Dade County Product Control Seal as shown below. 0*00
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 17-0322.03
MIAMFDADE ZUVIVI NTY Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
ADHESIVE PLACEMENT DETAIL # 1
t thr6sryFk plastic caenrat wakty 16oa�0sdktB.j
I
X44 10..,y
Eawtcoutse,
e la1n: Fault.
00
E6r0 Cinsur0
Nall throupkpisstic cement
Iwhest rsyulreal7
1Q W11 >
I in.wid
Battens optional
awa�ry d49n6,�eh rrr�l1
rmt Clasnra
Fosct.
!A tl.rnugtr plauic aenr- _
trd+us r•guk•dF paddy ($ea►mh.7i191
tin. wsda I :` • w
i�
FameCoursoIk ; � • •!" ff
r Fascia
Weephate
1Ciy ' �Earn d0swe
Of1p ad"
MIAMFDADE COUNTY
.... W
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) —23(148.4 cm2) square inch adhesive
contact with the underside of the tile. • • 6
• 969.
.. . • 0• 0
. •. •.. 669• •
• 999..9
9060Goo? 9.9.99
• •090% •
Medium Profile/ Double PAR File • • • • •
• • .....
.. ..
1. Starting at the eave cours*oapNy a mininjum 2
(50.8 mm) x 10" (254 mm) x 1: (25.4 mml foam • •
paddy onto the underlayjnegt•p�ositioaed A? Shown•
under the pan portion of thb the closest to the • • •
overlock of the tile being set. 0000 •
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 6 of 11
ADHESIVE PLACEMENT DETAIL # 2
N.+lghpWalre�mne P.dd�riMm.atAT�.l
iNldwiyjllf.l* �r 4
rye\ 1.
�'`"Zen. .., ✓'f' ``�, �».��'°`._
tl mwgh Punic mmem
mvuinwl
Oemath
16"ent QP60Mi
Fwtt"
MIAMNDADE COUNTY
c6+
Flat/Low Profile Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cm2)
—23(148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (596mm)
x 7" (177.8 mm) x 1" (25.4 rxm�4oam paddy Mto the • • ....
underlayment positioned as %�o wr: ander thy' •. •
strengthening rib closest to the pyprlock ofttl tile • • • • • •
being set. 4,00000 0 00
......
..........
3. Continue in same manner. InApepproximately 10" •
(64.5 cm2) - 12 (77.4 cm2) sgfiart�inch Ahesi ve •
contact with the underside orthl toe. •
...... ......
Medium Profile / Double Pan Tile •
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the Overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cm2) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
ft" tA.Ough *Lu-tk u '
t11hen required) ,i �-tiw .� P"Oy lRemoothTile)
tft
LKterAappti
�. c.
'"tes€ia
loin, 2 in few d9swe
CMAMEMADE
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
..0.
2. At the second course, apply 3 mOipum 2" •(S gmm) ......
x 7" (177.8 mm) x 1" (25.4 mm) foam pardy r qto the .'
underlayment positioned as shown under tA8Ift • • • •:.
0000
portion of the tile closest to tile« 9yerlock of tRe tile •
being set. *0006* • 9.0.0 •
• 0000.
666606 66 6
3. Continue in same manner. Itnsur�aPProZ" • 0
'at�S' 170000..
(109.7 cm2) - 19 (122.6 cma1%14ne inch adhesive 6 •
contact with the underside df the tile. ; • 0 0 0000:.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8 of 11
ADHESIVE PLACEMENT DETAIL # 3
Nail through pissticwnent Paddy (between tilesl
)when required)
sattern aption
° Paddy tunder tile)
ungle
ao mp af�tlleun
-'
on underla3tnetR t 2 x 4 h. `
• ta64
Fasda
bare domre
Flat/Low ProtiteTtle
Mail thromjb plastic cement Sk*e paddy under tie
(When required)
Pa ddy (between tiles.)
Battens paddy (under tdei
optionaI
Sirugie r
an.^'I�ti Y.4�
grin. 2.a
skoe.pa" on
unimm
a in. , 21n.
Ene Cksure
EaveCourse Fascia
Medium PratileTile
On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the Overlock of the tile being set. Leave
approximately 4" (10 1.6 mm) up from the eave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 int (109.7-148.4 cm2) of
adhesive contact with the uVderside of t4prti6
00
• •• •
•••••• • • • •
Apply a 4" (101.6 mm) x 44(eltU.6 mm) x f "(25.4 • • •.: •
mm) foam paddy onto theAeleiilaymer4 jus below �.•.•
the second course line positfdndfoamratltly •
under the strengthening ritUP fj�tt tile,.or uiader the* ".
pan portion of the tile, closesetb the urxferiack for .....
••r•
the second course tile to le installed. Insure • •
approximately 8-9 int (5L.6 -5$.l Crn):4f a(Aesive ....;.
contact with the undersidaaf ft tile. •
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
rhtn-Ppta5dt 51n}e pa" undertime
ixf�ace reQutedy
P&Mr ins sks)
satrap:
Paddyamdertire)
pad
an
Sk4e 2:4K
"3 de
EaMe Coarse Fasda
W-Phoie
101 2 io.
E3" dosufeDripedge
High Profile THe
MIAMMADE COU
....
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cm2) - 11 (71cm2) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cm2) -9(58.1 cm2) square inch
adhesive contact with the underside of the,,t J fat
the head of the tile. Contim:e irl same m3lager• •
•
•
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
1) Place enough adhesive to achieve 65 to 70 sq. in. Steep pitch applications
in contact with the pan tile. (when required)
2) Turn covers upside down. Place adhesive in
to 1 in. from outside edge of cover tile.
Then install the tile. Ensure 20 to
25 sq. in. contact area
Underlayment
Sheathing
Eave closure
(motar shown)
Weephole
Facia Board
Remove top portion of the save course cover tile. Abut to second course of
pan tiles. Ensure save end of pan and cover tiles are flush at save line.
Two Piece Barrel - High Profile Tile
MIAMFDADE COUNTY
• t
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocking until adhesive has a chance to
cure.
Continue in same manner bringing two. pan o
courses up toward the rid;%.•Ins*re • • • •'
•ee•e•
approximately 65 (419.4 cuti21 (4il keN2)
s •
e—,70
square inch adhesive con4wA.% �h the unatfside
so**:.
of the pan tile. '
Turn covers upside dowaldgVing thea underside '•:''
of the tile. Apply a minim>:VI" (25.4 An)•x 10"
••see•
(254 mm) bead of adhejiveedikctly on the inner • •
edge of each side of the:cov%r tile. I yg; . ... •; •
approximately 3/4" (19'1=ytt) V 1" (25.4 mm) •
from the outside edge of the tile, inw* aPS. free of •' •:
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan the course. Insure a minimum of
20 (129 cm2) - 25 (161.3 cm2) square inch
contact area on each side of the cover the to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11
M�IAMEQADE
LS�J11�� MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
Polyglass USA Inc.
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control,3eettgn to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdi ion•(AHJ). •
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County VroM t Control Section • • • • • •
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the,0ti;*Jt to have As :....:
product or material tested for quality assurance purposes. If this product or material fails to p%rfaM in the itee;ted •
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately rovake, modify, or • • ; •
suspend the use of such product or material within their jurisdiction. RER reserves the right4to revoke this 9aceptancc4.....
if it is determined by Miami -Dade County Product Control Section that this product or mate0a?fAb to meet the •
requirements of the applicable building code. • • • • • •
This product is approved as described herein, and has been designed to comply with the Floridadgilding Codi
including the High Velocity Hurricane Zone of the Florida Building Code. •
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 15-0410.04 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Semino.
NOA No.: 17-0614.22
MIAMMD0 6=1 NTY Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 1 of 8
ROOFING COMPONENT APPROVAL
Cateeory Roofing
Sub-Cateeory: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 2 of 8
Test Product
Product
Dimensions
Specification Description
Polystick IR -Xe
65'x 3'33/8"
ASTM D 1970 A fine granular/sand top surface self -adhering, APP
Manufacturing
Or 65'x 3'
polymer modified, fiberglass reinforced, bituminous
Location #1 & #2
60 mils thick
sheet material for use as an underlayment irl9"p roof
assemblies. Designed as an icj & ilia shield "' • • • • ; •
Polystick Dual Pro
61'x 3'33/s"
TAS 103 and A rubberized asphalt self-adhethi . gfass-frbe;pelyestery • • • •
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing membTAM.'Designed'as a
Location #2
metal roofing and roof tile unde1r, * ent. �...:.
.....
Polystick Tile Pro
61'x 3'33/8"
TAS 103 and A rubberized asphalt self-adhe*rtV,'gass-frbtr/ptlyestee • • •
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing membraii* �DesiAed'ds a metdP • • • •
Location #2
roofing and roof tile underlayrTrenf - '.
Polystick TU Max
65'8" x 33-3/8"
......
TAS 103 and A rubberized asphalt self-adharing,'polyes&r reinforced
Manufacturing
60 mils thick
ASTM D 1970 waterproofing membrane. Designed*as a aro-ptlge '
Location #1 & #2
underlayment. 0000
Polystick TU P
32'10" x 3'33/8"
TAS 103 and A rubberized asphalt waterproofing membrane, glass -
Manufacturing
130 mils thick
ASTM D 1970 fiber/polyester reinforced, with a granular surface
Location #2
designed for use as a tile roof underlayment.
Polystick TU Plus
65'x 333/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
(Surface Printing)
80 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Manufacturing
roofing and roof tile underlayment.
Location #1 & #2
Polystick MTS
65'8" x 333/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefrnic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Polystick MTS Plus
65'8" x 33 3/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefrnic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Elastoflex S6 G
32'10" x 3'3-%"
TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing
ASTM D 6164 with a sanded back face and a granule top surface. For
Location #2
use in roof tile underlayment systems.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Reaort
Date
Trinity ERD
P10870.09.08 -R1
TAS 103
12/04/08
P10870.04.09
TAS 103/ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
07/01/10
P33370.03.11
TAS 103
03/02/11
P33370.04.11
ASTM D 1623
04/26/11
P36900.09.11
TAS 103/ASTM D4798 & G155.�Cil1/81/11
P37300.10.11
TAS 110/ASTM D4798 & gV7O
�10/19/11
P40390.08.12-2
ASTM D 1623 ......
•.W91/12
P37590.07.13-1
ASTM D6164 ...:..
OW02/13
P45270.05.14
TAS 103, TAS 110 & ASTNJ'Dt6;3
05/92/14
P46520.10.14
ASTM D1623 **96
00• 00..
• 10/03/14
P44360.10.14
TAS 103 & TAS l ld*:**:
:'LOAV/14
P43290.10.14
ASTM D 1970 & TAS 0*Q„�
IVI7/14
PLYG-SC10130.06.16-3
TAS 103 & TAS 110
PLYG-10130.06.16-1
ASTM D1970 & TAS 110.
�06/;7/16
* 06171/16
PRI Asphalt Technologies
PUSA-035-02-01
TAS 103
: . jj7,9/06
PUSA-055-02-02
TAS 103
12/10/07
PUSA-089-02-01
TAS 103/ASTM D4798 & G155
07/06/09
Momentum Technologies, Inc.
JX20147A
TAS 103/ASTM D4798 & G155
04/01/08
RX14E8A
TAS 103/ASTM D4798 & G155
11/09/09
DX23D8B
TAS 103/ASTM D4798 & G155
02/18/10
DX23138A
TAS 103/ASTM D4798 & G155
02/18/10
LABELING:
0.000.
......
. .
0000.
0000.
0000..
0000..
0000..
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved”
or the Miami -Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick IR -Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick
TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered.
Surfacing: See General Limitations Below. ....
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
AnchorBase Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Membrane: Polystick TU Plus, self -adhered.
Surfacing: See General Limitations Below.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of 8
. .
....
......
Deck Type l:
Wood, non -insulated
• • • • • •
• • • •
......
Deck Description:
Min. 19/32" plywood or wood plank
.
• • • • • •
•
•
System Type E(2):
Anchor sheet mechanically fastened to deck, membrane adhered
• • • •
• •
.....
Anchor/Base Sheet:
One or more plies of ASTM D 226 Type II or ASTM D 2626.
.. • • • •
• •
• •
• • • • •
Fastening:
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at ahiiv tem 4"
heatl lap.
(for •,
base sheet only)
•
.so*
......
0...•.
Membrane:
Elastoflex S6 G, hot asphalt applied
•• •
. ..
:0900•
Surfacing:
See General Limitations Below.
90:900
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
AnchorBase Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Membrane: Polystick TU Plus, self -adhered.
Surfacing: See General Limitations Below.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of 8
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface,givigg speciaLige:tion • • • • • •
to lap areas. •• • ••
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembf} IoMnt Prohttot•Lontroi...
Notice of Acceptance..•.•..
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flgS4ing tapC tti tH be • • • • •
pressed in place and formed around the protrusion to ensure a tight fit. A second layeratf lialystic"hajl be �; • •
applied over the underlayment. " • • • • • • • • • •
w .
GENERAL LIMITATIONS: ......
w • • ..sewn
1. Fire classification is not part of this acceptance. " ' " •
. . .
2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR -Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR -Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR -Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR -Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Ex osure Limitations (Days)
MTS IR -Xe
Elastoflez TU
S6 G Plus
TU P
Tile Pro Dual Pro
TU Max MTS Plus
Winter Haven, FL 180 90
180 180
180
180 180
180 180
Hazelton, PA N/A 90
N/A 180
N/A
N/A N/A
180 N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 5 of 8
Rule 61 G20-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
. . 9999•
9 9999..
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, t$e Tn4ximurp9roa99f slope
shall be as follows: (See Table Below) 9 0 •.:..• 9999:.
Tile
Polystick
Elastoflex
Polystick TU Plus,
Polystick
Polystig$0 0
Syitem.(E3) ;
Profile
MTS
S6 G
TU P, Tile Pro,
TU Max
MTS PL%%.
MTSTU with .
Dual Pro
00:01
'F>EJ Phis •
Flat Tile
Prohibited
4:12
6:12
6:12
5:1;:.::,,
6:12
without battens
0•
Profiled
Prohibited
4:12
6:12
6:12
4:12
Tile
without battens
•
0000
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for
all underlayments except Polystick MTS which shall be loaded onto battens.
d
CL
0
N
N
POL,anCK1U Plus
9999.
9999
9999
9999.
9999.
9999.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 6 of 8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a-request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Section for apprgf1lTrpvided
that appropriate documentation is provided to detail compatibility of the products, wind upfirt resistfiMtLt, and fit`s
testing results. •
...... .... ......
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICR VNMBIIAW&% '
.... . .....
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIVINAPPLFCATIANS.
AL• • • • •
.. .. . .. ......
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOVUJUATIONS.. .'
. . . . ......
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood•decks.:iristalTem are •
cautioned to refer to applicable local building codes prior to direct deck installation to enure this ¢ Vmptable� •
Please also refer to applicable Product Data Sheets of the corresponding products. 0000
All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 %" metal disk as
required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6'/4"/12", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 7 of 8
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
0000
13. Questions in regards to the application of Polyglass products should be directed to our.Tecbnical St"W1rS ,• �,
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable pro*;cores as outlined by ."'�
the National Roofing Contractors Association (NBCA).0000 0 0
:Goo*:
• 6000.
6.6• . • 0000.
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SP>J'MUAPPLVATIONS.
•• •. • .• 0060..
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECO1VjIjATIONS. 6 •
• • • • 6666••
6666••
END OF THIS ACCEPTANCE : 66.6:
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 8 of 8