Loading...
REV-19-2219Miami Shores Village Building Department artment 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 ION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION FE-IBUILDING ❑ ELECTRIC ❑ ROOFING RECEIVED SEP 2 3 2% . tE - FBC 20 t-� Master Permit No. RIF 09-19-2090 Sub Permit No.V-�,rU -bc, -1 I " SION ❑ EXTENSION ❑ RENEWAL F-IPLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 49 NW 98 st City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO - Occupancy Type: res Load: Construction Type: CMU Flood Zone: BFE:. FFE: OWNER: Name (Fee Simple Titleholder): Kelly Southard Phone#: 305 725 6704 Address: 49 NW 98 St City: Miami Shores State: Fl Zip: 33138 Tenant/Lessee Name: Email: CONTRACTOR: Company Name: Designhome Remodeling Address: 290 nw 161 st Phone#: Phone#: 7863010857 City: miami State: fl 33169 Qualifier Name: F. anthony Geraci Phone#: State Certification or Registration #: CCCo57409 Certificate of Competency #: _ 7863010857 DESIGNER: Architect/Engineer: na Phone#: na Address: na city: na State: na Value of Work for this Permit: $ 600.00 Square/Linear Footage of Work:- ' Type of Work: ❑ Addition ❑' Alteration ❑ New ❑ Repair/Repl'ace Description of Work: add solar Vents Specify color of color thru tile:, Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ (Revised02/24/2014) CCF $ DBPR $ Zip: n ❑ Demolition CO/CC $ Notary $ Double Fee $ Bond $ Q TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work mitt be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which o s seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be ave and reinspection fe will be charged. Signature Signatur1�%a4 O NER or AGENT CONTRA OR The foregoing insRF1 ent ly s acknowledged before me this The foregoing "-4— day , 20 J by ci rite or who s produced identification and who did NOTR UBL Sign: Print: Seal: sssssss*sssssssssss'sssr APPROVED BY (Revised02/24/2014) is Dersonal v known to as :— ALBERT SEARA Notary Public • State of Florida W .a . Commission p GG 304563 Comm. Expires Feb 24, 2023 Bonded My through National Notary Assn. of me or who has prod owlegdged before.Me this /5n identification and who did take an oath. Print: Seal: ALBERT SEARA Notary Public - State of Florida Commission p GG 304563 My Comm. Expires Feb 24, 2023 as *s*sssss*ss*********s*s**************************************** 10.1/v( Plans Examiner Structural Review Zoning Clerk FLeFina Dsaaanhsxr eF . _ '� i ��"'ii: , Business 8 Pro#essional Regulation ''I'' f DBFF HQt¢ ASQU7 Ira Divi S1QN5 tM:TACT DBPR BaS Home Log In User Registration Hatropics SubmitSurcharge Stats & Facts Publications FBc staff Bas site map 1! unks search fbnda a Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail 'b1" FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email FL14826-R5 • • • Revision • • • • 2017 0000 Validated �"`a • • • • • • atube me ational, Inc piToalogidge Way Va,Ok 92081 (7W 597-4427 tanderson@solatube.com Todd Anderson tanderson@solatube.com Todd Anderson 2210 Oak Rid Vista, CA Quality Assurance Representative Address/Phone/Email RECEI V E0 Category lrtiL Ro g Subcategory ��%� , " ooflng Accessories that are an Integral Part of the Roofing SystbkP 2 3 ?fll9 Compliance Meth d Q��� Evaluation Report from a Florida Registered Architect or a Licensed P` Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert 1. Amoruso, P.E. the Evaluation Report Florida License PE -49752 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/25/2022 Validated By - Steven M. Urich, PE 2 Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL14826 R5 COI CI 1906 Rev4 417-0905 ss.odf Standard Year ASTM D1929 2012 ASTM D635 2010 ASTM D638 2003 ASTM E84 13a ASTM G155 05a TAS 100(A) 1995 TAS 202 1994 0 Sections from the Code Product Approval Method Date Submitted Date Validated Summary of Products Florida Licensed Professional Engineer or Architect FL14826 R5 EQuiv EER 1906 Rev4 417-0905 ss.Ddf Method 1 Option D 02/07/2018 02/13/2018 FL # Model, Number or Name • Description • • • • • • • • 14826.1 Solar Star Model RM -1500 Solar Powered Attic Roof Vent; RA -'•1%00 High Profilb for HVHZ • • • • Limits of Use Installation Instructions ' Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes •••••• •••• • Design Pressure: +50/-170 Evaluation Reports Other: •••• •. • 14826.2 Solar Star Model RM -2400 FL # Model, Number or Name • Description • • • • • • • • 14826.1 Solar Star Model RM -1500 Solar Powered Attic Roof Vent; RA -'•1%00 High Profilb for HVHZ • • • • Limits of Use Installation Instructions ' Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes FL14826 R5 II SOLA0006 REW*Q RNI-1500 ss.odE Verified By: Robert 3. Amoruso, P.E. FL Licen9 e1� � 1752 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +50/-170 Evaluation Reports Other: FL14826 R5 AE PER 1906 Rev4 417-0905 ss.odf Created by Independent Third Party: Yes 14826.2 Solar Star Model RM -2400 Solar Powered Attic Roof Vent: RM -2400 High Profile -for HVHZ Limits of use Installation Instructions Approved for use in HVHZ: Yes J FL14826 RS II SOLA0007 REV B RM-2400J4975 Appro ed for use outside HVHZ: Yes Verified By: Robert 3. Amoruso, P.E. FL LicenImpa Resistant: No Created by Independent Third Party: Yes Desig Pressure: +50/-170 Evaluation ReportsOther: FL14826 R5 AE PER 1906 Rev4 417-0905 Created by Independent Third Party: Yes FR 5-4 Contact Us :: 2G01 6Wir Stone Roae 7aiW�4 rnone: e The State of Florida is an AA/E Eo employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e -mal address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Semon 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dick here. Product Approval Accept ®®®®0 Credit Card Safe ri` Client: Product: Compliance Methods Product Category: Product Sub -Category: Prepared By: Project No.: Project Report No.: Revision: Date: Product Evaluation Report *000 Solatube International, Inc. . . .... ...... 2210 Oak Ridge Way Vista, CA 92081 ...... .... ...... Solatube "Solar Star" Solar Powered Attic Fan, Models RM-1206*9NA-160b.�RVHZ ...... ..:..' Product Approval Rule 61G20 -3.005(1)(d) — Product Evaluatfowgoport by a.Wtaased ...... Professional Engineer Roofing .. .. Roofing Accessories that are an Integral Part of the Roofing System Robert J. Amoruso, P.E. . Florida P.E. License Number 49752 PTC Product Design Group, LLC FBPE Certification of Authorization No. 25935 415-0316 1906 3 Q June 19, 2015 PTC Product Design Group, LLC PO Box 520775 Longwood, FL 32752-0775 Phone: 321-690-1788 Fax: 321-690-1789 FBPE Certification of Authorization No. 25935 Project No. 415-0316 Product Evaluation Report No. 1906, Rev. 3 Digitally signed by Robert J. Amoruso DN: cn=Robert J. Amoruso, o, ou=PTC Product Design Group, email=robert@ptc- corp.com, c=US Date: 2_0 15-06.2-9 13:50:59 -04'00' Evaluated by: Robert J. Amoruso, PE FL PE No. 49752 Page I 1 Project Scope Evaluate Solatube "Solar Star" Solar Powered Attic Fan, Models RM -1200 & RM -1600 for conformance to the 2014 Florida Building Code — Building and Residential Volumes including the High Velocity Hurricane Zone (HVHZ). Prepare the following: • Product Installation Details/Drawings (Reference 1) • . . .... ...... • Installation Anchorage Evaluation (Reference 3) •• •• • • Product Evaluation Report (this report) Description of Product — Installation Req ff" brnbWts .... .... ...... See Reference 1 for a description of the product, its installation and other pertinent datarel3ted to its-- • use. ...... Limitations and Conditions of Use • ' This product evaluation report contains or makes reference to specifications, technical details and installation details and/or methods that pertain to the proper use and/or installation of the product specified herein. Specific limitations and conditions of its use including but not limited to the following are contained in Reference 1 and are the subject of Product Approval in accordance with the State of Florida Product Approval Rule 61G20- 3. • Design Pressure Rating (psf) • Installation restrictions. • Installation substrate requirements. • Product description. • Installation anchor requirements. • Product components. Applications/Installations outside the Limitations and Conditions of Use of this Product's Approval Rule 61G20 -3.005(1)(e) states "Rational engineering analysis cannot be used in lieu of a standard test required by the Code for approval of products within the scope of the standard, except that project specific approval by the local authorities having jurisdiction in accordance with alternate methods and materials authorized in the Code." Any modification to this product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. As allowed in Rule 61G20- 3.005(i)(e), a project specific approval by the local authorities having jurisdiction may be used given an appropriate rational analysis is conducted and deemed acceptable to the local authorities having jurisdiction. PTC Product Design Group, LLC Project No. 415-0316 PO Box 520775 Product Evaluation Longwood, FL 32752-0775 Report No. 1906, Rev. 3 Phone: 321-690-1788 Fax: 321-690-1789 FBPE Certification of Authorization No. 25935 Page 12 Quality Assurance This product is manufactured under a quality assurance program audited by an approved Certification and Quality Assurance Entity Keystone Certifications Inc. (KCl) as required in Rule 61G20-3.005(3). See FBC Organization No. CER1523 and QUA1824 for approval under Rule 61G20-3. 0000 . . 0000 0000.. Code Conformance — Structural Perfo��nc-... .... 0000.. 0000.. The following structural and system performance criteria have been met. As recl fiired.by TAS-ONA) fdr goo*increased wind resistance of vents exceeding the dimensional limitations of Sectiori j14.1 of T4S-1Q0(A), a;..• uniform static air test in accordance with TAS -202 was performed. Testing to TAS 202'5'atNfies Secttdn -10.4.1 & • • Section 10.4.8 of TAS -100(A) thus allowing installations to heights not to exceed 75 feel. • �; Requirement FBC Code Reference Evaluation • • TAS 100(A) test. Roof Section 1523.6.5.2.13 TAS 100(A) testing conducted. See height limitations must Reference 2.a for results. be shown in drawing. Metal thickness must Table 1503.2 Metal Metal flashing and housing comply with Chapter Flashing Material. comprised of Aluminized Steel 15. Section 1507.2.9 Flashings EDDS T1-25 (Type 1) meeting ASTM - asphalt shingles. A463 (Aluminum -coated sheet Section 1518.9 Metal steel). Thickness is 0.028" which panels/shingles exceeds the both galvanized steel and aluminum thickness requirements. Impact to TAS 201, n/a Optional impact testing was not Optional performed. Uniform Static Air Test Required by TAS 100(A) to TAS 202 testing conducted. See to TAS 202. Safety obtain increased wind Reference 2.b for results. Factor of 2 applied to speed testing to maximum Safety Factor of 2 applied to results results. height of 75 feet. (see below). Section 1523.4 Wind Driven Rain to Section 1523.6.5.2.13 TAS 100(A) testing conducted. See TAS 100(A) — Optional Reference 2.a for results. The following installation restrictions are also applicable. 1) installation anchors match the test conditions. a. Anchor same size. i. No. 10 Tapping Screws ..6960 0000.. 0000 PTC Product Design Group, LLC Project No. 415-0316 Page 13 PO Box 520775 Product Evaluation Longwood, FL 32752-0775 Report No_ 1906, Rev. 3 Phone: 321-690-1788 Fax: 321-690-1789 FBPE Certification of Authorization No. 25935 b. Same quantity of anchors as tested. i. Eight screws minimum required by testing. Anchor calculations (Reference 3) performed. 2) State type of roof surface that must be used with the vent/fan. a. Asphalt shingles per Reference 2.a and 2.b testing. b. High -Profile roof tiles not to exceed three inches (3") in height per Reference 2.a and2 jbtesting. 6066 606666 .. . . 06 3) The following shall be placed on the installation instructions. • • 0 • 0000.. 00000. 0 . a. This approval is for the structural performance only. Impact resistance ves"ot tested. In00terior • • mechanism and/or electrical the this e :06 '. 999999 ' 9 circuitry are outside scope of apprd 6 9009 9 00 000.0 69.00. . . 96660 .. .. .. .. 0000.. DESIGN PRESSURE LIMITATIONS 0000.. .' . . . . 0000.. ....66 • From Reference 2.b, Uniform Load Structural Test Pressures where +100/ -VQ ' ; psf. 6 6 * 0: • In accordance with the 2014 FBC, Section 1523.4 a Safety Factor of 2 is applied to a o ' * Pt Design Pressures of +50/-170 psf. Code Conformance - Plastics The 2014 FBC, Section 2614.2 Definitions: Approved Plastics and Section 2606.4, Light -Transmitting Plastics/ Specifications require plastics to meet certain fire -related and outdoor exposure requirements. The fan grill is comprised of Polypropylene. Based on outdoor exposure testing and fire -related testing to ASTM D 1929, E 84 and D 635, the product described herein has demonstrated compliance with the 2014 Florida Building Code. Solatube "Solar Star" Plastic Component Polypropylene Fan Grill Code -Compliance as follows: 1. Outdoor Exposure Testing (Reference 2.c) per Sections 2614.2, Approved Plastics a. Documented Characteristics (from Reference 2.c): Architectural Testing, Inc. was contracted by Solatube International, Inc. to evaluate the tensile strength of their Solar Star Fan Grill before and after 4500 hours of Xenon Arc weathering for compliance with the FBC. The average tensile strength change was determined to be -5.9%, which meets the FBC criterion of ±10%. b. Code Compliance: Sections 2614.2 is met. 2. ASTM D 1929 testing (Reference 2.d) a. Documented Characteristics: A self -ignition temperature of 880'F PTC Product Design Group, LLC PO Box 520775 Longwood, FL 32752-0775 Phone: 321-690-1788 Fax: 321-690-1789 FBPE Certification of Authorization No. 25935 Project No. 415-0316 Product Evaluation Report No. 1906, Rev. 3 Page 14 b. Code Compliance: A self -ignition temperature of 650'F (3430C) or greater was met. 3. ASTM E 84 testing (Reference 2.e) a. Documented Characteristics (tested in manner to be used): Smoke Developed (Smoke Density Index) 250 b. Code Compliance: Smoke Developed (Smoke Density Index) not greater than 450 was met. 4. ASTM D 635 testing (Reference 2.f) a. Documented Characteristics: A CC2 Combustibility classification was received. *Osseo b. Code Compliance: Combustibility classification of either CC1 or CC2 w� mvt. • `•' ""0 .. 0000.. 0000 a•...• •. Performance and Testing Standard$• :sees: .. 0 0 0 0 •••• • 00 0000. 0 0 . 0 0 . 0 0 Reference 2 conducted testing to the following standard(s) . • 0 • • 0000. .. .. .. .. 0000.. 0000.. 11 TAS -100(A)-95, Test Procedure for Wind and Wind Driven Rain Resistance and/Or Irrcrtased 1Nindspeed 0000. Resistance of Soffit Ventilation Strip and Continuous or intermittent Ventilation:'ystQrn Instblled At the :0000: Ridge Area 0000 .... 2) TAS -202-94, Criteria for Testing impact & Nonimpact Resistant Building Envelope Components Using Uniform Static Air Pressure 3) ASTM G 155-04, Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non -Metallic Materials 4) ASTM D 638-03, Standard Test Method for Tensile Properties of Plastics. 5) ASTM D 1929 - 96(2001)e1, Standard Test Method for Determining Ignition Temperature of Plastics 6) ASTM E 84 - 09a, Standard Test Method for Surface Burning Characteristics of Building Materials 7) ASTM D 635 - 06, Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position References and Supporting Documents 1) Drawings a. SOLA0006, Rev. C, dated 5/11/2015, Solatube "Solar Star" High Profile RM -1200 Roof Fan — Installation Anchorage Details, signed and sealed by Robert J. Amoruso, PE. b. SOLA0007, Rev. A, dated 5/11/2015, Solatube "Solar Star" High Profile RM -1600 Roof Fan — Installation Anchorage Details, signed and sealed by Robert J. Amoruso, PE. 2) Testing a. Architectural Testing Inc. Test Report No. C1439.01-109-18-Ri, dated 8/23/12, "Solar Star" Solar Powered Attic Fan to TAS -100(A)-95, signed and sealed by Michael D. Stremmel, FL P.E. b. Architectural Testing Inc. Test Report No. C1439.02-109-18-111, dated 8/23/12, "Solar Star" Solar Powered Attic Fan to TAS -202-94, signed and sealed by Michael D. Stremmel, FL P.E. PTC Product Design Group, LLC PO Box 520775 Longwood, FL 32752-0775 Phone: 321-690-1788 Fax: 321-690-1789 FBPE Certification of Authorization No. 25935 Project No. 415-0316 Product Evaluation Report No. 1906, Rev. 3 Page 15 c. Architectural Testing Inc. Test Report No. A6443.01-106-31, dated 8/23/11, "Solar Star" Solar Powered Attic Fan Grill testing to ASTM G155 and D638. d. SGS U.S. Testing Company Inc., Test Report No. 2228540-3, dated 12/1/10, "Solar Star" Solar Powered Attic Fan Grill testing to ASTM D1929. e. SGS U.S. Testing Company Inc., Test Report No. 2228540-1, dated 12/1/10, "Solar Star" Solar Powered Attic Fan Grill testing to ASTM E84. f. SGS U.S. Testing Company Inc., Test Report No. 2228540-2, dated 12/6/10, "SolarStmessolar Powered Attic Fan Grill testing to ASTM D635. • • • • • • • • • • .. . . .. 3) Reports •••:0• •••• �•�••• 0000.. 0000 .. 0000.. a. PTC Report No. 2143, Rev. 0, So/atube "Solar Star" Solar Powered Attic Fd17! Models•RA'r-1200 &• •; • • RM-1600—HVHZ, Anchorage Engineering, Dated 8/15/12, signed and sHVIty Robe.l�: • 00000 Amoruso, P.E. 00000 • 0000.. b. PTC Report No.1906-CofE, Rev. 3, Solatube "Solar Star" Solar Powered 310- fain, Mvde1S.RM- 000000 00 0 1200 & RM -1600 — HVHZ, Equivalency Evaluation to 2014 FBC, Dated 6/!L9/;% Signed and0.. ; Sealed by Robert J. Amoruso, P.E. 00 ' .00. • • �; ' 0000 4) 2014 Florida Building Code —Building Volume a. Testing Requirements i. Section 1523.6.5.2.13 ii. Section 1523.4 b. Material Requirements i. Table 1503.2 Metal Flashing Material ii. Section 1507.2.9 Flashings - asphalt shingles iii. Section 1518.9 Metal panels/shingles c. Plastics Requirements i. Section 2612.2 Definitions: Approved Plastics ii. Section 2606.4, Light -Transmitting Plastics / Specifications PTC Product Design Group, LLC Project No. 415-0316 PO Box 520775 Product Evaluation Longwood, FL 32752-0775 Report No. 1906, Rev. 3 Phone: 321-690-1788 Fax: 321-690-1789 FBPE Certification of Authorization No. 25935 Page 16