Loading...
PW-18-24864� 0."', ■ ■■■ 4111 D 2001 Less Than 2001 ROAD WORK AHEAD 400' � 50' 200' 20' ROAD More Than WORK C 1001 AHEAD • ■v • • • • • • • • • ROAD • • • • • • • WORK • • • • � • • • • • AHEAD • 2001 200' 4001 H� ROAD WORK AHEAD 200' 409 CONDITIONS WHERE ANY VEHICLE, EQUIPMENT, WORKERS OR THEIR ACTIVITIES ENCROACH ON THE PAVEMENT REQUIRING THE CLOSURE OF ONE TRAFFIC LANE, FOR WORK AREAS LESS THAN 100' DOWNSTREAM FROM AN INTERSECTION FOR A PERIOD OF MORE THAN 60 MINUTES. CONDITIONS WHERE ANY VEHICLE, EQUIPMENT, WORKERS OR THEIR ACTIVITIES ENCROACH ON THE PAVEMENT REQUIRING THE CL05URE OF ONE TRAFFIC LANE, FOR WORK AREAS 200' OR MORE DOWNSTREAM FROM AN INTERSECTION FOR A PERIOD OF MORE THAN 60 MINUTES, 4. Flaggers shall be in sight of each other or in direct 9. Use Temporary Raised Rumble Strips in accordance with Index 603. DURATION NOTES communication at all times. Placement of Rumble Strips and additional signs should begin at SYMBOLS GENERAL NOTES ® Work Area 1. Work operations shall be confined to one travel lane, leaving 5. The FLAGGER legend sign may be substituted for the symbol sign. I ROAD WORK AHEAD sign may be omitted if all of the following FY 2017-18 pppTT the opposing travel lane open to traffic. INDEX NO. conditions are met: ■ Channelizing Device (See Index No. 600) 6. The maximum spacing between devices shall be no greater than 25.' 605 1 Of 1 2. When vehicles in a parking zone block the line of sight to TCZ a. Work operations are 60 minutes or less. Work Zone Sign signs or when TCZ signs encroach on a normal pedestrian 7. For general TCZ requirements and additional information, refer to b. Speed is 45 mph or less. walkway, the signs shall be post mounted and located in Index No. 600. C. No sight obstructions to vehicles approaching the work area for accordance with Index No. 17302. a distance of 600 feet. []O Flogger �- 8. The two Channelizing devices directly in front and directly at the d. Vehicles in the work area have high-intensity, rotating, 3. If work area is confined to an outside auxiliary lane, the work end of the work area may be omitted provided vehicles in the work flashing, oscillating, or strobe lights operating. b Lane Identification + Direction of Traffic area shall be barricaded and the FLAGGER signs replaced by area have high-intensity rotating, flashing, oscillating, or strobe e. Volume and complexity of the roadway has been considered. ROAD WORK AHEAD signs. Flaggers are not required. lights operating. 4. Flaggers shall be in sight of each other or in direct 9. Use Temporary Raised Rumble Strips in accordance with Index 603. communication at all times. Placement of Rumble Strips and additional signs should begin at FLAGGER sign location. LAST REVISION DESCRIPTION: �, FY 2017-18 pppTT TWO-LANE, TWO-WAY, WORNEAR IINTERSECTIION INDEX NO. SHEET NO. 07/01/15 ,r DESIGN STANDARDS 605 1 Of 1 / 934 f 9701 ,4� �P ` 948 960 990 9655 1002 1020 1032 1058 1076 +(tIP 0tic. I1 5, OL NE 9TH W E, 50' TOTAL_ u_ res vi �, 1025 1045 1055 — — , — — , s , 1015 �� TO' ED BY -_NE-97-TH-ST------- t� 1� 1026 1044 1064 1084 2 I� S � 1041 1055 E: 973 987 � Q LOCATION MAP FLXL LAW • ....�.. Srfp" ASPHALT '. MPLAmoiT BASE : ...,., • OE11 MAM W• i s • t1DTH 1 r 00 ••••• 1 1Y �...• 00 • REaTORATrome OF ROAD CUT •0•00�FOR:U.-N4TY CROSSING GENERAL*NOfiES 1. REPLACED BASE MATERIAL OVER DITCH SHALL BE TWICE THE THICKNESS OF THE BASE. MIN. 8" AND MAX. 18- 2. BASE MATERIAL SHALL BE PLACED IN 6" MAX. (LOOSE MEASUREMENT) LAYER AND EACH LAYER THOROUGHLY ROLLED OR TAMPED TO 98X OF MAX. DENSITY PER AASHTO T-180 3. ASPHALT CONCRETE PAVEMENT JOINTS SHALL BE MECHANICALLY SAWED 4. SURFACE MATERIAL SHALL BE CONSISTENT NTH SURROUNDING SURFACE MATERIAL (1.5' MIN. THICKNESS) 5. BASE MATERIAL SHALL HAVE A MIN. LBR. OF 100 AND A MIN. CARBONATE CONTENT OF 70X (60X FOR LOCAL STREETS) 6. CONTRACTOR SHALL SOFT DIG TO VERIFY LOCATION OF EXISTING UTILITIES LEGEND - f CENTER UNE M MONUMENT UNE R1W RIGHT OF WAY P/L PROPERTY UNE E.O.P. EDGE OF PAVEMENT T. T, TAPPING TEE E.F.V. EXCESS FLOW VALVE SVC SERVICE UNE PE PLASTIC STM. SEW. STORM SEWER DATE BLDrz SEPT 1 1 37.5 SU ECT I"O CChIPI_If ICE U, H All FE ER STATE AN,) trC i�N',°{ �UL_S AP D REGULA-rjo� S 23' Nff F..I Ur . 5l C6ofe Is,"-, .. _ � .. NO CAP N P/LT �', FOuND S DRILL HOLE >ra R E C E t V E v"-' ` PROP. GAS`S !. RISER m SEP 19 2018 ' c M :L - GAS MAIN /. • �_ _ . _ PL SOD RESTORATION DETAIL a 1 ONE STORY 1 P.=250 rT=24 7 d CW3515' N E SCALE:1'=20' i 60' 1 30' 24 13 o i o LijW I w 121 CL SCALE NOT TO SCALEI SINGLE FAMILY RESIDENCE f i I 2.4' pool #990 s P` ' SVC FV9 ALL EXISTING UTILITIES SHOWN ON THESE PLANS ARE TO BE lid -FL: 60 � CONSIDERED APPROXIMATE & �. SHOULD BE VERIFIED BY THE ' I r, I `^ O f`f CONTRACTOR PRIOR TO THEPpLVERS' .t ?� — f z I START OF WORK OPERATIONS. t C F:,! PROP. 3/4 t. L. GAS ;d_ 11L IN SVC. TI SVC. TO BE . PAS 'I-! GAS MAIN T DIRECTIONAL WI T T. TIE. F. V. Q Iuewn>✓ BORED 33CL LA2' 30' UT 15ALLEY(N.A.F.) EXIST. 2" P. E. GA - = MAIN 1-3 1 1 1 1 1 1 1 Drawing File: G:\Documents\MIAMI SHORES\990 NE 97 ST MIAMI SHORES FL 33138\990 NE 97 ST MIAMI SHORES dwg 08/28/2018 m coc P, 0 m co co 02 Ca c o aD a 0 z > (i QQa G a 3-j o� Uu w,<c,m W c, E t � Q W BW^f "s 2 ^ z 1 0 i or aszrm ET No.: 1