Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
MC-19-1195
Location Address Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Daft: 06/03/2019 Parcel Number 351 NE 105TH ST, Miami Shores, FL 33138 1122310130290 Contacts Permfr'No.: MC -0&19-119$ Permit Type. Mechanical - Residential Work Classification: A/C Replacement Permit Status: Approved Expiration: 12/02/2019 Description: A/C CHANGE OUT Valuation: $ 9,030.00 Inspection Requests: 305-762-4449 Total Sq Feet: 0.00 Fees SARAH ENGEL Owner 351 NE 105 ST, MIAMI SHORES, FL 33138 DIRECT AIR CONDITIONING INC Contractor JUAN SOTOLONGO Business: 3055962666 JUAN@DIRECTAC123.COM $50.00 CCF $6.00 Description: A/C CHANGE OUT Valuation: $ 9,030.00 Inspection Requests: 305-762-4449 Total Sq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $6.00 DBPR Fee $4.74 DCA Fee $3.16 Education Surcharge $2.00 Permit Fee $266.05 Scanning Fee $9.00 Technology Fee $7.90 Total: $348.85 Payments Date Paid Amt Paid Total Fees $348.85 Credit Card 05/24/2019 $50.00 Check # 3142 06/03/2019 $298.85 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I ce t—al e fo information is accurate and that all work will be done in compliance with all applicable laws regulating coDstfu0i nd zo ' em I p ze the above named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent Date June 03, 2019 Page 2 of 2 BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 RECEIVED MA 2 4 2019 BY: Tel: (305) 795-2204 Fax: (305) 756-8972 - r INSPECTION LINE PHONE NUMBER: (305) 762-4949 (, t� FBC 20 Master Permit No. W`6 -t; Sub Permit No. ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL PLUMBING 'MECHANICAL ❑PUBLIC WORKS [:] CHANGE OF M CANCELLATION ❑ SHOP 1 �L CONTRACTOR DRAWINGS JOB ADDRESS: S's/ 1\,)� / 0 � -P/ Folio/Parcel#: I /- d d- J / -VI J ^ �- U Is the Building Historically Designated: Yes NO_ Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Ti/t�le�older): o'(& � Phone#: Address: / v Q S IZ city: r\kk G Tenant/Lessee Name: Email: State: Zip: 33 J Phone#: CONTRACTOR :%C any Name: c , , Phone#: 6,6 Address: / &c oo �" )-q C City: ' ` l �CA.AState: �' �- rr�� Zip:_c,� Qualifier Name: TU (�-�OACgV Phone#: State Certification or Registration #: _ �/V^� S a- - DESIGNER: -DESIGNER: Architect/Engineer: Address: Value of Work for this Per44$— $ 0 3-D Sq Type of Work: ❑ Additi ❑ Alteration ❑ New Description of Work: Specify color of color thru tile: Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ (Revised02/24/2014) of Competency #: r Footage of Work: ❑ Repair/ReplarA Zip: ❑ Demolition CCF $ CO/CC $ _ DBPR $ Notary $. Double Fee $ Bond $ nn QQ TOTAL FEE NOW DUE $ d -1� Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all, applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:' Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction ' n a brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notic of comme a ent must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is is ued. I t sence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature , Signature ' OWNER or AGENT CON CTOR The foregoing instrument was acknowledged before me this The foregoi g instrument as acknowledged before me this (� day of 20 9 by� d 20 by 4 who is personally known to .5a a G� , wh is ersonall own me or who has produced as me or who has u as identification and who did take an oath. identificatio and who did a an ath. NOTARY PUBLIC: NOTARY P BLIC: Sig L/tit Sign: Print: J2f'ld� �!1� Print: C A 2`y Seal: Seal: JOSE GONZALEZ ,ern Puaic stag a Fr«a. = "' Notary r Notary Public - State of o'da i Sandi Pena Y �: Commission: CC- 153539 COmmK p41913 _ 9 My Comm. Expires Oa 22.2021 ***********#**YNI:il�7�********* **********************i*'S.�Flt�lJfi�!drlRfl�IfIFA'aF#i�s1S'!* ********* w APPROVED BYCw— Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33168 Tel: (305) 795.2204 Fax:(305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on sin le sheets are not acceptable. being rdone Job Address where the work is . S1 !' " 6,J� ) )0 City: Miami Shores Village County: Miami Dade Zip Code: ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITAtS AHRI DATA SHEET REQUIRED Change disconnecting means: YES ❑ NO ARHI Sheet Attached: YES E5/NO ❑ Contract Attached: YES 0� 1. Minimum Circuit Ampacity (Wire Size): 2. Maximum Overcurrent Protection (Fuse/Breaker 3. Voltage of CirgName: 80): 4. Size Disconne Contractor's Comp�� State Certificate oro. 0 Signature C �"hone• ks— 64 6• Certificate of Competency No. Date: (Revised02/24/2014) UNIT BEING REPLACED DATA NEW UNIT kke MANUFACTURER IeA (w uiol AHU or PKG. UNIT MODEL # () 0 Otto COND. UNIT MODEL # 6 KW HEAT NOM TONS AH CU 2OPKG 1) M.C.A AHU CU 1YaPKG AHU40 CU Q PKG 2) M.O.P AHU CU 30PKG AHU CU PKG 3)VOLTS AHU CU PKG PKG UNIT / / PKG UNIT / / EER/SEER YES NO REPLACING DUCTS YES N YES NO REPLACING THERMOSTATY-6 NO YES NO NEW 4"CONCRETE SLAB YES NO YES NO NEW ROOF STAND YES NO YES NO NEW RETURN PLENUM BOX YES NO 1. Minimum Circuit Ampacity (Wire Size): 2. Maximum Overcurrent Protection (Fuse/Breaker 3. Voltage of CirgName: 80): 4. Size Disconne Contractor's Comp�� State Certificate oro. 0 Signature C �"hone• ks— 64 6• Certificate of Competency No. Date: (Revised02/24/2014) Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax:(305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on sin le sheets are rnoot acceptable./1 Job Address (where the work is being done,. S1!' " 6 1 V City: Miami Shores Village County: Miami Dade Zip Code: ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS AHRI DATA SHEET REQUIRED Change disconnecting means: YES[-] NO ARHI Sheet Attached: YES !rJ n0 ❑ Contract Attached: YES ©� 1. Minimum Circuit Ampacity (Wire Size): 2. Maximum Overcurrent Protection Fuse Bre 01 3. Voltage of Circuit (2*240/4110)o^ 4. Size Disconnect' g M Contractor's Comp y Na State Certificate or Re 'st Signature (Revised02/24/2014) UNIT BEING REPLACED DATA NEW UNIT MANUFACTURER e-AFyur� (� tJ1 AHU or PKG. UNIT MODEL # • O COND. UNIT MODEL # V3 KW HEAT NOM TONS AH 0 CU 2OPKG 1) M.C.A AHU CU TY,4PKG AHU60 CU PKG 2) M.O.P AHU CU 3OPKG AHU CU PKG 3) VOLTS AHU CU PKG PKG UNIT / / PKG UNIT EER/SEER YES NO REPLACING DUCTS YES N YES NO REPLACING THERMOSTAT Y NO YES NO NEW 4"CONCRETE SLAB YES NO YES NO NEW ROOF STAND YES NO YES NO NEW RETURN PLENUM BOX YES rNU 1. Minimum Circuit Ampacity (Wire Size): 2. Maximum Overcurrent Protection Fuse Bre 01 3. Voltage of Circuit (2*240/4110)o^ 4. Size Disconnect' g M Contractor's Comp y Na State Certificate or Re 'st Signature (Revised02/24/2014) This combination qualifies for a Federal Energy Efficiency tax Credit when placed in service between Feb 17,2009 and Dec 31, 2016. Certificate of Product Ratings AHRI Certified Reference Number: 10259480 Date: 11-23-2018 Model Status : Active AHRI Type: RCU-A-CB Series: MERIT 14ACX SERIES Outdoor Unit Brand Name: LENNOX Outdoor Unit Model Number (Condenser or Single Package) : 14ACXS036-230A•• Indoor Unit Model Number (Evaporator and/or Air Handier): CBA27UHE-036-230'+TDR Region : Southeast and North (AL, AR, DC, DE, FL, GA, HI, KY, LA, MD, MS, NC, OK, SC, TN, TX, VA, AK, CO, CT, ID, IL, IA, IN, KS, MA, ME, MI, MN, MO, MT, ND, NE, NH, NJ, NY, OH, OR, PA, RI, SD, UT, VT, WA, WV, WI, WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. The manufacturer of this LENNOX product is responsible for the rating of this system combination. 0 _ i I Rated as follows in accordance _ dance with the latest edition of ANSI/AHRI 210/240 with_ Addenda 1 and 2, Performance Rating of Unitary Air -Conditioning & Air -Source Heat'Pump Equipment ang subject to ra`ting accuracy byAHRI-sponsored-independent, t iird,party testing: Cooling Capacity (A2) =,Single or High Stage (95F), btuh :34600 �Uy I E SEER 1 16.00 1 EER (A2) -Single or High Stage (95F) :13.00 +� `111I11 �j1i i lU Q ( r �c�} C,� f ti� , U 0 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced."Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Retinas that are accompanied by WAS indicate an involuntary re -rate. The new Dublished ratina is shown alona with the Drevious (i.e. WAS) rating, DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorizedalteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, AM personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The Information for the model cited on this certificate can be verged at www.ahridirectory.org, click on "Verify Certificate" link we make life better" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above, and the Certificate No., which is listed at bottom right. ©2018Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: (31874755862017242 RAISED seal below authenticates original copies. Photo copies are not acceptable. 40 PREMIER ORRT OCTAUTNGRf� 113 O;eION — INV91MGAT6 • INGFRCT 2393 TUYOARORA TRAIL, MAIT4ANO, FL 29791 Pt1ONis 407.297-7416 W W W,PR6M19R-*TRUOTURAL.00M PROJECT NAME., LENNOX RESIDENTIAL UNITS — WIND LOAD COMPLIANCE PER 2017 FBC DATE: 2/24/2018 TO: MR. TOM BRITTAIN BRAND/PRODUCT MANAGER — COOLING LENNOX INTERNATIONAL RE: RESIDENTIAL UNITS - 2017 FLORIDA BUILDING CODE WIND LOAD.CALCULATIONS FOR NON - ROOFTOP INSTALLATIONS Mr. Brittain, Per your request, we have analyzed the complete Lennox Residential Line of units. Our analysis was performed in -accordance with the 2017 Florida Building Code using the following Wind Design Criteria. • Ultimate Wind Speed =186 miles per hour • Risk Categories = III and IV • Wind Exposures = C and D • Non -Roof Install Height of up to 10 feet above ground As a result, we have concluded that only the 39.5inch long by 35.5inch wide cabinet LENNOX ELITE and DAVE LENNOX SIGNATURE SERIES require additional screws for non -rooftop installations of up to 10 feet above ground. (Reference page 6 for model numbers) All other residential units may be installed as manufactured. (Reference pages 2 to 5 for model numbers) Please note that our analysis and results pertain only to the LENNOX unit itself and its ability to maintain structural and panel integrity under severe wind events. The attachment of the units to the building structure and the adequacy of the underlying building structure are not our responsibility and shall be determined by others (i.e. building engineer of record or third party engineer). If there are any questions please feel free to contact me. Kharl A. Rodriguez, PE Florida PE#t 60239 LENNOtr REMENTIAL UNns-20 PL atm coal[ PREMIERS L ENO a Cb zein THE FOLLOWING URRS MAY 9S USED AT NOr4ROOFTOPSISTAIL TIONS OF UP TO U FEETAB04EGROM WITELO jPANEL MOOIFCATRXIS. produce line Base She !rand Coll Prolecilon Louver ooslgn Model Nvrnber Dimenslons Length Width IROW inches Inches inches Lennox Hort. 13ACX-018-230-17, -18 Lennox Hom 13ACX-024-230-19,-20 Lennox Vertical 4AC 13L) SP -7A, -8A 24.25 24.25 25.25 Lennox Vertical 4AC 13!24? -7A, -8A Allied vertical 4AC13L18P-7,8 Abed Vertical 14AC 13L24P-7 8 Lennox Harz. 13ACX-030.230.18, -19 Lennox Harz. 13ACX•036.230.17, -18 Lennox Harz. 14ACX-0t8-23OA" Lennox Hort. 14ACXS018.230A•' Small Lennox Vertical 4AC131.301'-7A,-8A Lennox Vertical 4AC13L36P-7A,-8A 24.25 24.25 2935 Lennox Vertical 4AC14LISP-6A Lennox Vertical 4AC 14LS 18P -6A AIAed vertical 4AC13L30P-7.8 Allied Vertical 4AC 13L36P-7.8 Allied Vertical .4AC I 4L 1 OR-614AC I4RL18P-6,7 Lennon Hoe 13HPX-018.230117, -19 Lennox Hors- 13HPX-024.230.17.-19 24.25 24.25 33.25 Le;nnOx Vertical HP13L18P-7A Lennox Veikal 4HP13L24P-7A Lennox Hoa- t3ACX-042-230.17,-18 Lennox Harz. 13ACX-060.230.17. -18 Lennox Harz, 13HPX-030.230.17. -19 Lennox Harz. 14ACX-024.230A" Lennox Harz 14ACX$024.230A•* Lennox Hort 14HPX-018.230.19 Lennox Vertical 4AC I3L42P-7A.-8A Lennox Vertical 4AC13L60P-7A,-SA 28.25 28.25 29.25 Lennox Verticof 4AC I4L24P-6A Lennox Vertical 4AC145L24P-6A Lennox Vertical 4HP13L30P-7A Lennox Vertical 4HP1.4L18P-7A Allied VevNCd 4AC I3L42P-7,8 Allied Vertical 4AC I 3L60P-7,8 Allied Vertical 4AC14L20-6,7/4AC14RL24P-6,1 Lennox Hors. 13ACX-048-230-19. -20 Lennox Hoa. 13HPX-048-230-17. -19 Lennox Hort 14HPX-036-230-19 Lennox Hoe 14ACX-042-23OA- Lennox Harz. 14ACXS042-230A" Lennox Vertical 4AC 13L48P-7A,-aA Lennox Vertical 4AC14L42P-6A,-7A 2825 28.25 33.25 Lennox Vertical 4AC 141S42P-6A,-7A Lennox Vertical 4AC I4L48P-6A, -7A Lennox Louve; Vertical 4HP13L4SP-7A Lenox Vertical 41 -11`141.36P -8A Ailled Vertical 4AC14L42P-6,7 Allied Vertical 4AC I4RL42P-6,7 Ailed vertical 4AC14148P-6.7 Mealtlm Lennox Harz. 13HPX.036.230.17. -19 Lennox Harz. 13HPX4)60-230-17, -19 Lennox Hoa. 14ACX-030.230A" Lennox Hon. 14ACXS03023OA" Lennox Hoa. 14ACX-036-230A'• Lennox Hort. 14ACX5036-230A" Lennox Hort 14ACX-04 1 -230-03 Lennox Hoa, 14ACX-M-'230.14 Lennox Horz. 14HPX-018-23OA20 Lennox Hoa. 14HPX-024-230-19 Lennox Horz 14HPX-030.230.19 Lennox Vertical 4AC 14L30P-6A Lennox Vertical 4AC 14L36P6A. -7A Lennox Verticat 4AC141.S30P-6A 26.25 28.25 37.25 Lennox Verticol 4AC 14L536P6A, -7A Lennox Vertical 4AC 14L48P-BA Lennox Vertical 4HP13L36P-7A Lennox Vertical 4HP13L60P-7A Lennox Vertical 4HP 1411 BP -8A Lennox VertEcol 4HP 14L 124-8A Lennox Vertical 4HP 14L30P-8A Allied Vertical 4AC 14L30P-6;7 Alfred Vertical 4AC 14RL30P-6,7 Allied Vertical 4AC 14L36P-6.7 Awed Vertical 4AC 14RL36P-6,7 AI$ed Vertical 4AC 14U1P-6.7 Allied Vertical 4AC141.471`46 7 Lennox Hoa. 13HPX-042-230-17. -19 26.25 28,25 43.25 Lennox Vertical 4HP13L42P-7A Letvox Harz. 14ACX-047-230-03 Merit/Aire- Lennox Hort. 14ACX-060-?30-11, -14 � 3225 33.25 Lennox Vertical 4AC14L60P-6A.7A Ro/Allied Allied Vertical 4AC14L60P-6.7 Lennox Hom 14ACX-059-230.04 AACSF 2 OF R X KWENTALUNITS • 2011 FLORIDA BIFLOON CODE PREAM SULICTOAO CAF 2311 THE FOLLOW!<NO (OATS MAYBE USED ATNOWIIOOFTOP 01STALLATIONS OF UP To 17 FEETABOYE OROMMOTHOU PANEL VOODGTOM Dimensions Product Una lase Sim Brand Cog Protection Louver Design Model Number Length Width Height Inches Incites Inches Large Lennox Harz. 14HPX-042.230-19 Lennox Harz. 14HPX-048.230.19 32.25 32.25 3715 Lennox Vertical 4HP14L42P48A Lennox Vertical 4HP14L48P-8A Ailed Vertical 4AC14L59P-6,7 Lennox Harz. 14HPX-UO-230-19 32,25 3225 43.25 tennox Vertidol 4HP14L60P-SA Lennox 73ACP0.i8 V0*/5:;. Lennox 13AGD 24.25 24.25 25.25 ANied 4A6131118P-7.8 Allied 4AC 13B24P•7.8 Lerrtox TSA036541443Y tell't(mx 15A036S4N43G Lermax TSA03"144Y Small Lertnoi TSAOt6:4T!44G 24.25 24.25 29.25 AtNed 4AC13B30P-7,8 AL4ed 4AC 13836P-7,8 Allied 4AC14B18P-A7/4AC14RB18P-6,7 Lennox Lennox 24.25 2425 33.25 Lennox A03654N44Y Lennon TPA03654N44G Lennon T3ACB230-1'7;...' I-emnox 1SA042S4N.43Y Lennox ISAU42S4N43G Lai+rax TSA0A2S4N44Y Lerux?x FSA04234N44G 28.25 28,25 2925' Lennrn 1PA036H41`442L; Lervxu IPA.03014N42Y Ailed 4AC13842P-7,8 A1led 4AC1386OP-7.8 Alled 4AC14824P-6,7/4AC14R824P-6,7 Allied 4HP 14B 18P-8• Allied 4HP 14B24P-7• Lennox Ailed 4AC 14942P•6,7/4AC 14R842P-6,7 Allied 4AC 14648P•6,7 Lenox 1PA.O49S41444Y Ler•n6x TPA042S444AG Ler+xlx TFA048541445Y Ltrrwtox TPA048S4N45G 28.25 28.25 33.25 Lerr,ON 1$A06PS4N43Y Leen. Wire Guard I;CAi16954N43G medium LU3rno,: ISA060541444Y Lr. r;.io+ TSA!16054N44G Lery+oy TPA4136H4N43G Uwnox TPA036H4N43Y Lennox 13ACP-04fi 23D 17..::.:. ; : Allied 4AC 14B30P-6,7/4AC I4R83DP-6.7 Allied 4AC14836P-6.7/4AC14RB36P-6.7 Lennox TSA94041443Y Lennon 4,',04-S4N43G Lennox TSAA146S41444Y Lennox TSAD45S41444C Lennox TPACDRS41445Y 28.25 28.25 37.25 Lennox TF•A096S4144SG Ler:nn. PA048S4N44Y Leww TPA04SS4rJ44G Lento. TPAO6ui4445G Lennon TPAOt5S414ASY L6nnoA TPACK46S N45Y Lelv,,ox T(AOl:0S4N45G Lennox TPA042S4N45Y Lennox TPA042S4N45G 2815 28,25 43.25 lannox TPAOSM4N44Y Lennox 1PA060S4N44G Lonox TPA042H4N42G Lennox TPA042H4N42Y Lennox TPA042HAN43G Lennox TPA042H4N43Y 32.25 32.25 37.25 Lennox TPA048H4N42G Lennox PA048H4N42Y Lenox TPA048H4N43G 1PA048H4N43Y einna. TPA060H4N42G TPAJo0H4N42Y rAffeennox TPAO60H4N43G 32.25 32.25 43.25 enno PAOrUH4N43Y d 4AC 14B6OP-6.7 Lennox Harz XCI34718.23D-44, -05 28 27 27 Lennox XC 13.024-23"7, -08 XC13,03& IM3.04 Lennox Lennox Herz. IXC14-011i XC13-036-230.07.-08 28 27 31 Smolt Lennox 2=A" EL16XC1410.230A PAr.F A OF A LENNOX RE3tDWK URRS-?M FLORDA BUILDING CODE PFISIMER FIRUCTUItAL ERGIRMOO CAN MIS E FOLLOTMf6 UMS MAY GE USED AT Wx4toOFroP VOTAUXIOISOF UP 1010 FEET ABOVE GROUND yQTjJ aPANEL MOW MIDRIL Dimendolls Produol Line Bate Size Brand Cob Prafectlan Louver Design model Number Length Width Height Inches Inches Inches Lennox XP13-018-230-10, -11. -12 Lennox Hort. XP13.024-230-10 -11, -12 28 27 35 Lennox XP16.024-230-11 Lennox XC 13-060.230.08. -10 Lennox XP13-030-230.09.-10 hrnrlQX XC 14-024.23DA'- lennox Hors. XCI6-036.230.OS 35 305 31 Lennox XC i 6.5036-230-05 Lennox SS6036H4S45Y ELIsxci-o24-23DA Lennox SS8036H4S45G XC 13-048.230.06. -OS Lennox Lennox Horz. XP 134}48.230.09 35 30.5 35 Lennox XCI'4.042-230A" ELIeXCI-042.23oA Elle Lennox Louver XP14.036.230-10 XC 13-042-230-03. -04 Lennox Lennox XP13-036-230-09 Lennox XP134)60.230-09 medium Lennox XC14-03D-230A'- ELisxCI.03o-z3DA Lennox C14.036 -230A'• GLIGXCi-03s-230A Lennox XC14S036.230A" Lennox XC14-041.2304Y1 EL16xc1.al•23044 Lervlox Horz. XC14-048.230-08 ELSOxe1440.73600 35 305 39 Lennox XP14.OIB-230A10 Lennox P144)24-230-09 Lennox XP1443D-2304W Lennox XC16-048.230-04 Lennox XCI63048-230-04 Lennox SSB04BH4544Y Lennox SSBO48H4S44G XCI6-024.230.04 lennox Lennox Hon. XCI6SO24-230-04 35 30.5 45 Lennox XP13-042.230-09 4SCU t3LE I 1 EF -5' Hort 4SrU13LE124P-5- 26,75 24.75 25.75 4SCU 13L8118P-3' 43CU T3L8124PJ' 4SCU13LE130P-54 4SCU13LE136P•5' Small AlliedASCUI3LBI3OP-8' 4SCU131.8136P-3' Horz. 26.75 24.75 29.75 4SCU 14LB 118P-7' 4SCU14LBR18P-71 4SCU 14LE1 ISP -7' 4SCU 16LS 124P-1' Hort. 4HP16LT24P 26.75 24.75 33.75 4SHP16LS124P 4SCU13LE142P-51 4SCU13LE16OP-51 45CU13LB142P-3' 4SCU13LB169P-3' ASCU UM 24P-7' Hom 4SCU14L8R24P-7' 31.25 29.38 29.75 4SCU1ALE124P-7' 4SCLIMER120-7' 4SCU14LE142P4' 45CU1413142P-4' 4SCU141RR142P-7' 4AC 16LS 136P-1 A 4SCU13LE148P-5• 45CU13L6f48P-3' 4SCU 14LE142P-7' 4SCUI4LER142P-7' Horz. 4SCU14L8142P-7• 31.25 29.38 33.75 4SCU14LBR142P-7' 4$CU14LB148P-4• 4SCU i 4LE 148P-4' 4SHP14LB136.7 4SHP14LE136-7 4SCU14LE141P-4 Medium ABied 4SCU 14LE147P-4- 4SCU14LB130P•7- 4SCU14LBR130P-7" 4SCU14LB136P-7' 4SCU14LSR136P-7• 4SCU14LE-13OP-7' Abed Rounded 4SCU14LER136P-7' Squrne louver 4SCU14LE136P-7' 4SCV14LER136P-7- Horz. 45CUT6L5148P-1 31.25 29.38 37.75 4SHP140118>' 7 ASHP14LB124P-7 45HP14LE113OP-7 4SHP14LEIISP-7 4SHP14LET24P-7 PAM: QnFR LENNOX REST EVM UNIT3-2017 FLORIDASULINNO CODE FitUM 9TRUCTURALMOMERM GAF 19517 FMLOWFiO UMTS UAYSE UW AT NCMAX* 70P MSTALLATMN S OF UP TO t9 FEET ABOVE GROUNDNM PANEL MOMATO M Product Una Base Site Brand Golf Protection Lower Design Model Number Dimensions Length Width Illelght Inches nNros Inches aer_c R nr a FNNOX RESIDENT S• 2037 FLOWABULDINGCOOS PREMIER STRUCTURAL K%GCAt44117 THE iOLLOMING UWS KOM FIELD NOWICATIONS (AODnION I SCREYIS) FOR NOWROOFTOP MISTALIATUNt6 OF UPTO TOFEETABOVE GROUND, olmenslons Product Line Base Size Brand Coli Proleellon Louver 0asign Model Number Length YvIdM1 HeIpM Inches Inches Inches Lennox XC14-047.23044RL1sxc1*4I,-ma4 Lennox XC 14060.230-04. -05 Lennox Harz, XPI"36.230.09 F116XO14 0.23404 39Z 35.5 35 Lennox SP8036H4S48Y Lennox XP 16048-2304D8 Lennox B048H4$46Y XP14-042-290-09 Lennox Lennox XPI4.048.230-09 Lennox Harz 39:5 35.5 39 Lennox XC2C20-02Q036--2" Lennox XP20-024.230A" Elite Large Lennox Louver XP2o-036.230A•• XC I6.060.23D OS Lennox Lennox XC16S060.230.05 Lennox SB060H4S44Y Lennox SS8060H4S45G Lennox X&14-060.230-09. Lennox Hort XP16-060.230-M 39.5 35.5 45 Lennox SPDD6014AS46Y Lennox XC20-048.23oA•• Lennox XC20-060-23oA•• Lennox XP20.048.230A•' Lennox XP20-060-230A'• Lennox xPI7-024-230-09 Lennox XP17-030-230-10 Lennox XP17-0.76.230-09 Lennox XPi7-042-230-09 Lennox Hca- XP21-024-230-07 39.5 35.5 37 Lennox XP21.036430-06 Lennox XP25.024-230-01 Lennox XP25.036.230.01 Lennox SL18XP1.024.23OA" Lennox SL 18XP 1-030.230A" XC 17.024-230-M Lennox Lennox SL18XC1-030.230A•' Lennox Harz SLI8XC1-036.230A" 39.5 35.5 41 Lennox SL18XC 1-042-230A'• Lennox SL I8XPI-036.230A^ Lennox SL18XP1.042.230k" XC 17.030.230-08 Lennox Lennox XC 17-036.230-08 Lennox XC 17-042-230-08 Lennox XC 17-048-2" Dove Lennox Lennox XC 17.060.230-08 Signature Sones large Lennox Louver P 17-048-230.09 Lennox P17-M-230-09 Lennox L I BXC I.024-230A" Lennox SLI BXC 1-048.230A" Lennox L18XC I.060430A" Lennox SL18XP 1-048.230A" Lennox SL18XP1.06043DA" Lennox XC21-024-2 10 Lennox Hom XC21.036.230.10 39,5 35.5 47 Lennox XC21.048.230.10 Lennox XC21-060-230=11 Lennox XP21-048-230-06 Lennox XP21-060-230.06 Lennox XC25-024-230.01 Lennox XC25-024.230-02 Lennox XC25-036-230-01 Lennox XC25.048-23&01 Lennox XC25-060.230-01 Lennox XC25.060.230.02 Lennox XP25-048.230.01 Lennox XP25060-230-01 ALLIED IW'U'm AJNOtSW= MODELS 7rcl:K. r,,TrI LEAN-NION INSTALLATION PROCEDURE 507575-01 August 21, 2015 Installation Kit for Securing Elite and Dave Lennox Signature Series Louvers for High Wind Events (141110) Units that are exposed to wind. shalt be designed and Installed to resist the wind pressures determined in accordance with the Florida Building Code. This kit consists of this instruction and four sheet metal screws. This kit Is required for medium and large base Elite®and all Dave Lennox Sigrnature®Collection outdoor units. REQUIRED TOOLS: Electric or cordless drill, drill bit capable of drilling into metal (.125" or 1/8"), 114" nut driver or drill socket. 13. •c. DIM 1113" DIM "C" MEDIUM BASE 30.50 35.00 LARGE ME 35.50. 39.40 DAVE LENNOX SIGNATURESCOLLECTION A WARNING! BEHIND THE LOUVER PANELS IS THE OUTDOOR COIL WHICH CONTAINS R41 OA HIGH PRESSURE REFRIGERANT. HAZARDS EXIST THAT COULD RESULT IN PERSONAL INJURY OR DEATH. TAKE EXTREME CARE WHEN DRILLING THE HOLES INTO THE LOUVERS OR BASE LIP TO PREVENT PUNCTURING THE REFRIGERANT COPPER PIPES. STEP A - DRILL 1N THE LOCATIONS INDICATED. DRILL ONLY THROUGH THE LOUVER. DO NOT PENETRATE THE UNIT BASE LIP. THE BASE LIP WILL NEED TO BE DRILLED AFTER THE LOUVER IS REMOVED. REPEAT STEP FOR THE OPPOSITE SIDE LOUVER. STEP B - REMOVE LOUVERS AND DRILL THROUGH THE BASE LIP WHERE MARKED BY THE DRILL BIT WHEN DRILLING THROUGH THE LOUVERS IN STEP A. IMPORTANT - WHEN DRILLING THROUGH THE BASE LIP, PROTECT THE COIL FROM DAMAGE BY PLACING A SOLID OBJECT (PIECE OF METAL, BLOCK OF WOOD, ETC.) BETWEEN THE LIP AND THE COIL. PROVIDED SCREWS TV SHEET METAL SCREW 100020-01 #8-18 x 314" WITH SPHERICAL POINT STEP C - REINSTALL LOUVERS AND SECURE TO THE BASE USING THE PROVIDED SCREWS AND THE HOLES PREVIOUSLY DRILLED. DIM "B" DIM "C" SL7ESAME 34.50 35.00 DAVE LENNOX SIGNATURESCOLLECTION A WARNING! BEHIND THE LOUVER PANELS IS THE OUTDOOR COIL WHICH CONTAINS R41 OA HIGH PRESSURE REFRIGERANT. HAZARDS EXIST THAT COULD RESULT IN PERSONAL INJURY OR DEATH. TAKE EXTREME CARE WHEN DRILLING THE HOLES INTO THE LOUVERS OR BASE LIP TO PREVENT PUNCTURING THE REFRIGERANT COPPER PIPES. STEP A - DRILL 1N THE LOCATIONS INDICATED. DRILL ONLY THROUGH THE LOUVER. DO NOT PENETRATE THE UNIT BASE LIP. THE BASE LIP WILL NEED TO BE DRILLED AFTER THE LOUVER IS REMOVED. REPEAT STEP FOR THE OPPOSITE SIDE LOUVER. STEP B - REMOVE LOUVERS AND DRILL THROUGH THE BASE LIP WHERE MARKED BY THE DRILL BIT WHEN DRILLING THROUGH THE LOUVERS IN STEP A. IMPORTANT - WHEN DRILLING THROUGH THE BASE LIP, PROTECT THE COIL FROM DAMAGE BY PLACING A SOLID OBJECT (PIECE OF METAL, BLOCK OF WOOD, ETC.) BETWEEN THE LIP AND THE COIL. PROVIDED SCREWS TV SHEET METAL SCREW 100020-01 #8-18 x 314" WITH SPHERICAL POINT STEP C - REINSTALL LOUVERS AND SECURE TO THE BASE USING THE PROVIDED SCREWS AND THE HOLES PREVIOUSLY DRILLED. P.O. BOX 948067, MAITLAND. FL 327 ph: 407-227-7416 web: www.promier-structumi.com CerGficote of Authorization! 29113 LENNOX RESIDENTIAL U TiE-DOWN REQUIREME 4" MIN rYP. 40" MAX (8) TIN: DOWN BRACKETS MIN 14 GA. MIAMI TECH CLIP OR EQUIVALENT REF. SHEET 2. ,mom• 40N MAX SHEET NO.: t OF GI MAiED 9Y: M+ DATE: 208 to CRF]CxEI) ft Km DAZE: 4/2 /2816 Stka uta ._._ DDML NOTE&, I. ALL aNL9Ri0N5 AND THa NMIRII mal1(too u MHN.) of MEOIAIQ<'J!L u14T SHALL CON W W LiATAMS STA10 MGM. Mt dLAWAI. LLHIT SPEpnCA=d (a= SpACI:, m# AC[. m) WALL ec PFS THE MAHUFACIURER'S REODMIMAW S AND ARE THE MWWN6111 M of IM WIRACIOR. 2 tt ft= REFEAINIA i+O W= mu m TAA WuEx Ar ORA ANN F5#3 410 s1A1 M FM 90 OR ENXIYmn sm A ium sCH m" RR ANCHOR = AND DOMIA 1T WWOMM ALL 9W W& scRElye usm TD FAstE1N MRAtaxis TO MIMMtICAL INTIM WALL K /10 (t4 MN 11O&Z PER INCH) AM F593 AD ETAILESS SiEEL OiLY OR EWYA M. FWME (6) PnYJlES WUNI PAST 1HE iHWO PLANE Ft R %W KETAL USM ALL FABIEt1ER1 SHALL HAVE APPAOMIE OMROM PR07H3CIICN m PREVENT EIL<CIRa.YSIL 3. iE SUBSTRATES SHALL Ln AT A NNHMUM 4' MGL AND iMiH A WI1MOY COHIPIl6S W SiR" TIE DOWN BRACKETS OF 3oo0 PI' CA. MIAMI TECH CLIP EQUIVALENT REF. 4, CMIRACIOR SHALL IMMIE ALL NORM AM :ET Z. AiTALiIAE M FROM 05SMI LAR NAiM0 N OIOER 10 FREW aE0IROLYSHI. T7, CECYWAL GtOl" (Al RWIJp" SHALL BE DESWIM By O1NER1. a A0IAUACY OF INE 013 NO NAM SBttt(IL" 10 tInWMD 2~00 LOW SMALL K OEiama By ON= 7. wAtER-111Ni M OF ESM sUBSIRAIE SHALL BE THE FULL RIMIMOMW OF THE OWAUM OWMACTOHt 0WIR CM 9VU WK THAT ANY RFN1014Yx OR ALUM WAIIAPROMM iE1iWM 19 RES10RE0 AFieM NtTALLAI,CN OF MfriIWAL uNHn PIS" sne,cluwu. EHOe+EE1" W. STALL NOT BE MMPO1911E FOR ANY RAIMPIR 0 OR LEAKAOR ISSUES YAIL11 MAY OMM "M WAM-110ii M IS OE INE AU FS PONSIOMY OF INE iWALLMO CONTRACIM 1111thi { � FLORIDA EXPOSURES BUILDING CODE RULTIMATE OOF HEIGHT DESIGN TWIN 60 SPEEED 186MPH - RISK CATEGORIES - III AND t "f/Hti111N1111�". Z!6 6966LL61r56 auudW4d snidslJad 'cul xOuual Wd ZL:6tP:Z LI,0Zl0I,A00 P.O. BOX 948067, MArRAND, FL 32794 ph: 407-227-7416 wet: www.promier—structural.com p Certiflcots of Authorization# 29113 Nm DESIGN CRITERIA; 2014 FLORIDA BUILDING CODE - U RISK CATEGORIES = III AND IV -- MEAN ROOF HEIGHT UP TO 60 FEET #10-14 S.S.-----"- SELF TAPPING SCREW (3 PER CLIP). ATTACH CUP TO NON --LOUVER PORTION OF UNIT SIDE PANELS. SEE SHEET 1 FOR CLIP LOCATIONS. 8" LONG x, 1" WIDE ANCHOR CLIP STAINLESS STEEL BY MIAMI TECH OR EQUIV. ANCHOR TO ---` SUBSTRATE SEE SCHEDULE ,m I iYNnY YLC KNi111 �,5� INRTL 1 ATY)N VEEr No.= 2 ._ OF CALCLILATM gy; KAN pA . z/z512ote CHECKED V. KAR DAM 2125/21318 SCALE: Nis ITE DESIGN WIND SPEED = 186MPH EXPOSURES = D ��1111t111 qN1/Illi ',v:G�NSE •,, Z-A KHARL RODRIGUEZ, PE FL #60239 ANCH SCHEDULE CONCRETE: (1) - 1/4" DIA. 410 STAINLESS 4" MINIMUM THICKNESS STEEL TAPCON OR EQUIVALENT. MIN. 3000 PSI 1 3/4", EMBED - 3" MIN EDGE DIST. - 4" MIN SPACING STEEL' (1) - 1/4" DIA. STAINLESS MIN. THICKNESS = 0.125 SIJEL THRU BOLT W/ S.S. WASHERS NAD NUT. MIN. YIELD STRENGTH = 33 KSI Z/Z 6966LL6b56 ousdwod snids;+sd lul xouual INd ZVEIV Z L40Z/NA00 i AIR CONDITIONING RESIDENTIAL & COMMMCIAL Billing Address Engel, Jerry 0003138 351 Ne 105 St. Miami, FL 33138 DIRECT AIR CONDITIONING 12200 SW 129 CT MIAMI FL 33186 (305) 596-2666 www.directacl23.com Licensed and Insured CACOS7328 Estimate Details Estimate 16495410 Job 16493557 Estimate Date 5/16/2019 Completed Date Technician Arturo Barro Customer PO Job Address Jerry Engel 351 Northeast 105th Street Miami Shores, FL 33138 USA Duct cleaning / 3 ton lennox system: Duct cleaning nadca standarDs with elektra machine for 16 vents,level 1,install two Solaris air purifier in plenum ANY ELECTRICAL UPGRADES NEEDED OWNER MUST HIRE LICENSED ELECTRICIAN AND PULL ANY NECESSARY PERMITS IF ANY ACCESS HOLES NEED TO BE MADE FOR INSTALLATION OF UNIT DIRECT AIR WILL NOT BE RESPONSIBLE TO SEAL OR PATCH UP ANY HOLES DIRECT AIR WILL NOT BE RESPONSIBLE FOR ANY DAMAGES Task # Description Quantity Your Price Your Total Level 1 - Dud Cleaning Certified NADCA members clean to National Standards which include 1.00 $1,400.00 $1,400.00 source contamination removal throughout your system. Your AC components will not be damaged during the cleaning. The airborne contaminants removed will be contained with our HEPA filtered vacuum equipment. Certified NADCA members also abide by a mandatory code of ethics which states that we shall serve customers with honesty and integrity and uphold the NADCA standards and guidelines. Cabin Clean Cabin Clean 1.00 $0.00 $0.00 Closet Clean Closet Clean 1.00 $0.00 $0.00 Sanitation Ensuring Air Quality Safety and Eliminating Airborne Contaminants in 1.00 $0.00 $0.00 Commercial and Residential Heating and Cooling Systems. A critical component of industrial hygiene is a facility's heating, ventilation and cooling (HVAC) system. Customer Appreciation Customer Appreciation Discount - Thank you! 1.00 $-50.00 $-50.00 Discount Solaris with UV Light The Solaris is a filtration system that removes particles, gasses, and/or 2.00 $1,100.00 $2,200.00 Stick chemicals from the air within a given area. These machines draw air in from the surrounding environment and pass it through a series of filters to remove contaminants. 3 Ton 14ACXS036 - LENNOX 14ACX MERIT SERIES- The 14ACX air conditioning condensing 1.00 $5,630.00 $5,630.00 CBA27UHE036 - ECB29 unit is an economical, environmentally responsible home cooling system - 9kw -16 SEER where you will always feel the temperature inside your home'just right' without the worry of the high utility bill. LENNOX CBA27 ELITE SERIES - The Lennox Elite series CBA27 family of air handlers makes it easy to save money on energy bills, year after year. That's because it is the first family of air handlers to use the Lennox quantum coil; a proprietary, enhanced aluminum tube and fin coil engineered for long-lasting corrosion resistance. LENNOX HEATER ECB 29- Electric heat element. 10 Year Compressor; 10 Year Parts; 3 Year Labor Warranty. FPL Rebate 1.00 $-150.00 $-150.00 With FPL's $150 instant rebate, getting a new energy-efficient air conditioning (A/C) unit for your home is no sweat. A new system will not only contribute to your home's comfort, it can help you save money on your energy bill year after year. Included with Included with Installation are the following items: AC Stand, Locking Caps, 1.00 $0.00 $0.00 Installation Float Switch, Hurricane Tie -downs. In addition, ArmaFlex, Mastic, Dud Board, Foam, Adhesive Glue, Black Tape & Aluminum Tape. Permit Included Permits help protect you by avoiding unlicensed contractors and are 1.00 $0.00 $0.00 required to protect all people from the effects of repairs, replacements or new construction which are in violation of the current codes which could cause harm to life and/or property. Honeywell Pro 6000 - THERMOSTAT- A thermostat can often be the main control unit for a 1.00 $0.00 $0.00 Programmable heating or cooling system, in applications ranging from ambient air control. Concrete Slab 40x40 CONCRETE SLAB- An air conditioner condenser unit must survive all types 1.00 $0.00 $0.00 of weather in the yard outside your house. The condenser unit is also fairly heavy, prone to vibration and creates water as it condenses. Therefore, a solid, waterproof pad is a necessity. Potential Savings $360.00-$923.00 Sub -Total $9,030.00 Tax $0.00 Total $9,030.00 Thank you for allowing Direct Air Conditioning the opportunity to serve you ! GENERAL TERMS AND CONDITIONS OF SALE, DELIVERY AND SERVICE LIMITED WARRANTY: All materials, parts and equipment are warranted by manufacturers or supplier???s written warranty only. All labor performed by above named company is warranted for one year for all new unit installations, six month on replaced parts, ninety day for water leaks (water leaks due for lack of maintenance are not covered), or as indicated in writing. Direct Air Conditioning will not be responsible for any property damage due to malfunctioning unit and/or water leak. Direct Air Conditioning makes no other warranties, express or implied and its agents or technicians are not authorized to make and such warranties on behalf of the above named company. RETENTION OF TITLE: Ownership and Title to and equipment or materials (the goods) furnished by Direct Air Conditioning (the seller) shall remain vested in the seller and shall not pass to the buyer until the purchase price for the goods has been paid in full and received by the seller. Until title to the goods passes: The Seller shall have authority to retake, sell or otherwise deal with and/or dispose of all or any part of the Goods; the Seller and its agents and employees shall be entitled at any time and without the need to give notice, and/or without the need of court intervention, enter upon and property upon which the Goods or any part are stored or installed, or upon which the Seller reasonably believes them to be kept: the Buyer shall store or mark the Goods in a manner reasonable satisfactory to the Seller indicating that title to the Goods remain vested in the Seller, and; the Buyer shall be responsible for insuring the Goods to their full replacement value against damage from fire, water and theft at its own expense. Any amounts due from insurance claims or claims arising from tortuous act in the event of loss or destruction are hereby assigned to Seller, in this case, at seller???s request, buyer must provide seller with all the necessary information for collection, and must allow an authorized representative to review the statures of the assigned claims. Irrespective of whether title to the Goods remains vested in the Seller, risk in the Goods shall pass to the Buyer upon delivery. Until the secured claims are paid in full, the good subject to retention of title can neither be pledged to third parties nor assigned. Buyer must immediately inform seller of any third ???party access to Seller???s property. LEGAL FEES: In the event Direct Air Conditioning is required to bring any legal proceedings regarding the sale, delivery and service of the agreement, the buyer agrees to pay to all costs, including reasonable attorney fees, court costs and ancillary expenses incurred by Direct Air Conditioning in enforcing its rights. RETURN POLICY: ALL SALES ARE FINAL. No refunds or exchanges will be given. An order may be cancelled only if done before the equipment or materials (the goods) have been delivered and installed. However, once and order has been successfully charged to a debit/credit card. All cancellations could be subject to a 20% fee. Furthermore, Buyer agrees to waive any and all rights to disputing the purchase of materials, equipment or services though AmericanE sMasterCard, and Discover???s internal dispute procedures. Any and all request for returns and or exchanges will be handled directly though Direct Air Conditioning. I the customer agree with the Terms and Conditions given by Direct Air Conditioning. JOSE covzAz cla Cor. -r. _x:"es bar_ thro�ch ,12hCrzi A:t3ry Asir.