Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-19-224
1�1 1 Location Address Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: Parcel Number 117 NE 102ND ST, Miami Shores, FL 33138 1132060131810 Contacts Perim NO.: RF -01-19-224 Permit Type: Roof Work Classification: Tile Permit Status: Approved Expiration: 07/30/2019 Description: RE -ROOF TILE Valuation: $ 19,000.00 Inspection Requests: Total Sq Feet: 2,091.00 Fees FERNANDO TORO Owner 117 NE 102 ST, MIAMI SHORES, FL 331382324 DEL SOL ROOFINGENTERPRISE INC Contractor LISSETTE PACHECO Business: 3052295722 $50.00 CCF $11.40 Description: RE -ROOF TILE Valuation: $ 19,000.00 Inspection Requests: Total Sq Feet: 2,091.00 Fees Amount Application Fee - Other $50.00 CCF $11.40 DBPR Fee $4.50 DCA Fee $3.00 Education Surcharge $3.80 Roofing Fee $250.00 Scanning Fee $9.00 Technology Fee $7.50 Total: $339.20 Payments Date Paid Amt Paid Total Fees $339.20 Credit Card 02/12/2019 $289.20 Credit Card 01/31/2019 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construcJion and zoning. Futhermore, I authorize the above named contractor to do the work stated. Authorized Signature: Owner / Applicant r Contractor / Agent Date February 12, 2019 Page 2 of 2 won" 4225 SW 71 Ave, Miami. FI 33155 Tel: 786-398-9179 Fax: 786-800-2627 a1 roofinspection(MQmail.com LAB CERTIFICATION #16-0510.15 SITE SPECIFIC INFORMATION UPLIFT TEST - TAS #106 04/12/20.19 Roofing Contractor DEL SOL ROOFING Job Address 117 NE 102 ST . Owner's Name FERNANDO TORRID Type of Tile FLAT 13" Approximate Roof Height 12 feet Roof Pitch 4/12 Approximate Square Footage of Roof 21 ftZ Date Tested 04/12/2019 Number of Tests 55 Contact Name HEYMI t�i4js qj c`t Permit # RF0119224 Date Installed Type of Access to Roof LADDER Required Testing Force 35 Lbs Testing Equipment F.G.E.100 Phone # 305-228-0218 LOCATION # OF TEST PASS # OF TEST FAIL Corner 10 Tests 10 Pass Test Fail Perimeter 10 Tests 10 Pass Test Fail Field 21 Tests 21 Pass Test Fail Ridge 14 Tests 14 Pass Test Fail TOTAL 55 Tests 55 Pass 0 Test 0 Fail IN ACCORDANCE WITH THE rCRIT+�ERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPUFT QUALITY CONTROL TEST. THIS TAS 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREM,1. P,XiJF Oili011ry /iY.WITH NO DEVIATIONS. THIS REPORT IS NOT GUARANTEED IN CASE OF CASE OF NATURAL DISASTERS. THIS REPORT IT 15 NOT VAUD FOR INSURANCE CLAIMS. ti �+ •.L'`1 � r 'FfEr6`,'4�� Job Address 117 NE 102 ST Permit Number RF0119224 Roof Drawing NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. `V `rTAX FOLIO STATE OF FLORIDA; COUNTY OF MIAMI-DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following Information is provided in this Notice of Commencement. 2. Description of Improvement: N: 20190074336 BOOK 31315 PAGE 4656 TE:02/06/2019 11:57:54 AM RVEY RUVIN, CLERK OF COURT, MIA-DADE CTY Space above reserved for use of recording office L3 3. Owners) name and address:) Interest in property: --- Name and address of fee simple titleholder: 4. Contractor's name, address and phone n 5. Surety: (Payment bond required by owner from contractor, if any) Name, address and phone number: ___ Amount of bond $_ / 6. Lender's name and address: - 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided t;y Section 713.13(1)(a)7., Florida Statutes, Name, address and phone number: S. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name, address and phone number: 9. Expiration date of this Notice of Commencement: (the expiration date is t year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR I.�NDER ORSANwATTOt?NEY SEFQRE OR RECORDING YOUR NOTICE OF COMMENCEMENT. �a r' � 7C>p"' Signature(s) of O 0 ner(s)' Rut orized Officer/Director/Partner/Manager �1 �[(�f� E'er l� �3 t?•G Prepared By ' _ �I _ Prepared By Print Name "'1J�'� Print Name Title/Office _ _ Title/Office STATE OF FLORIDA COUNTY OF MIAMI-DADE The fore Inst ant knowledg d before me this day of _ 0 Individually, or 0 as __.C1,(A4�7Zi for _— L) Personally known, or�'produced the following type of identifica i Signature of Notary Public; _ -- Print Name: _ (SEAL) SikRY4s JAVIER PJIG 3(FICATiON PURSUANT TO SECTION 92,52S, FLORID STATUTES a� F' NOTARY PUBLIC Under penalties of perjury, I declare that I have read the foregoing and o "ATE OF FLORIDA P R 1 7. e9 9 �.,�, `�{ that the facts stated in it are true, to the best of my knowledge and belief. �,r ' Cnmmg GG3785.5e Ex�3iI8Sb4/0/2021 Signature(s) of Owner(s) or Ow. ner(s)'s Authorized Offlcer/Director/Partner/Manager who sign o a ov By t2301-52 PAGED 12 BUILDING PERMIT APPLICATION Miami Shores Village RECEIVED BuildingDepartment p JAN 3 12019 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 ,{ INSPECTION LINE PHONE NUMBER: (305) 762-4949 v' FBC 2014 Master Permit No. 9— (: l q - Z z "1 Sub Permit No. ❑BUILDING ❑ ELECTRIC [Y(ROOFING ❑ REVISION ❑ EXTENSION [D RENEWAL ❑PLUMBING ❑ MECHANICAL PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION F-� SHOP CONTRACTOR DRAWINGS JOB ADDRESS:117�- r'le \O dr City: Miami Shores County: Miami Dade Zip: 'J?s 1.s Folio/Parcel#: j�.T�e6_ 9 ?) - tS t© Is the Building Historically Designated: Yes NO . Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder):�'�r,p "ZZ+n� Phone#: Address: 1thl, L \b 'A- city:1���� � .y—_g State: Zip: 2) k. 3P Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name. '` \ ©L. {a1bO��n� Phone#:. o -,04 Address: City: N.X % C�L ffs ., State: C -S Zip: 21514[g Q Qualifier Name: L2\ 55�4^ _ �a 0.C.t..2,CE1 Phone#: Z05- AS -9904`O State Certification or Registration #: 6cc - /3Z 4805--+ Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ State: Zip: 2'a-7170( ear Footage of Work: Type of Work: ❑ Addition n ❑ Alteration `J ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: -47 re Specify color of color thru tile: &-fa I <,,r Submittal Fee $ Scanning Fee $ Permit Fee $ CCF $_ Radon Fee $ DBPR $ Technology Fee $ Training/Education Fee $ Structural Reviews $, (Revised02/24/2014) CO/CC $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ �Jq 2-U _98C�_, . 2-0 Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued in the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT The foregoing instrument was acknowledged before me this day of ',164oi 20 7 T by who is personally known to me or who has produced dL _ as identification and who did take an oath. Signature CONTRACTOR The foregoing instrument was acknowledged before me this day of 20 1!3� by fi who is personally known to me or who has produced identification and who did take an oath. as NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: Print: Seal: aOtPRYASS-T; NOTARY PUBLIC D�pRygs JAVIER PU 14 oe STATE OF FLORIDA Seal: o� sow NOTARY PUBLIC GG078559 2 STATE OF FLORIDA o�sComm# of� . 413012021`a Comrn# GG078559 pilil�rs*isss*********** ** * APPROVED BY (� Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) 11/9/2018 Property Search Application - Miami -Dade County Y.t:.AI ..OFFICEOF THEPROPERTY Summary Report Property Information Benefit Save Our Homes Cap Folio: 11-3206-013-1810 2018, $211,570 $109,8981 $912 $322,380 $122,334, 117 NE 102 ST Property Address: Building Value XF Value Miami Shores, FL 33138-2324 Owner FERNANDO T TORO $25,000 117 NE 102 ST Mailing Address Second Homestead Exemption MIAMI SHORES, FL 33138-2324 PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). 0101 RESIDENTIAL -SINGLE Primary Land Use 0942 $107,400 17662- Exemption Value FAMILY: 1 UNIT Beds / Baths / Half 2/1/0 Floors 1 Living Units 1 Actual Area 1,723 Sq.Ft 1,448 Sq.Ft Living Area Adjusted Area 1,579 Sq.Ft 8,475 Sq.Ft 1948 Lot Size Year Built Assessment Information Benefit Save Our Homes Cap Type Year Land Value 2018, $211,570 $109,8981 $912 $322,380 $122,334, 2017 $211,570 $109,898 $928 $322,396 $119,818 2016 $211,570 $109,898 $944 $322,412 $117,354 Building Value XF Value Market Value Assessed Value Benefits Information Benefit Save Our Homes Cap Type 2018 2017 2016 Assessment Reduction $200,046 $202,578 $205,058 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 1 AMD PB 10-70 LOT 17 & LOT 18 LESS E1/2 BLK 13 LOT SIZE 75.000 X 113 OR 20369-0942 01 2002 4 Generated On : 11/9/2018 Taxable Value Information OR County Exemption Value Taxable Value 20181 1 $50,000 1 $72,334 2017 $50,000 $69,818 2016 $50,000 $67,354 School Board Qualification Description Sale Exemption Value 1 $25,000 $25,000 $25,000 Taxable Value 1 $97,334 $94,818 $92,354 City 0942 $107,400 17662- Exemption Value $50,000 $50,000 $50,000 Taxable Value $72,334 $69,818 $67,354 Regional 2571 Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $72,334 $69,818 $67,354 Sales Information OR Previous Price Book- Qualification Description Sale Page Sales which are disqualified as a result of 20369- 01/01/2002 $0 0942 $107,400 17662- examination of the deed Sales which are qualified 05/01/1997 2132 12/01/1984 $74,000 12373 Sales which are qualified 2571 10/01/1982 $61,000 11587- Sales which are qualified 0676 The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: NW %-#U11%A111y vcNaI L1111CIIIII, 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FI 33138 0000 date;• 3t9% 0000.. 0000.. 0000.. . 0000.. ••t••• �n� �`©'cb 000 Re: Owner's Name: 0 00 a • ••00 •• •• Property Address: t *0:00: :900:0 0000 Roofing Permit Number: 0000.. 0000. 0000. 0000.. 0000.. • • 0000.. Dear Building Official: 0000.. certify that I am not required to retrofit the roof to wall conrieciions of my building because: e(fhe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) gnature Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this day of I A TIER PUIG oP �� NOTARY PUBLIC ' STATE OF FLORIDA Notary Public, Sate of Florida at Large Comm# GG078559 Expifes 4/30/2021 • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS .... . . .... ...... 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor tDrovide th4swabcwith ' required roofing • • • ...:. the re q g permit, and to explain to the owner the content of the section. The" JVQ�i�ipns of ec on R440� govern the minimum requirements and standards of the industry for roofing system instaiWipns. Addil onally, the ; • • • •; following items should be addressed as part of the agreement between the owner ant Ov."iractor.'Tbd Jvnees..... initial in the designated space indicates that the item has been explained. • •.... 0*:*** .. .. . ...... 2• Renailing wood decks: When replacing roofing, the existing wood roof deck may4ve to be nailed in accordance with the current provisions of Section R4403. (The tQgf %pk is usually concealed prior to removing the existing roof system). 4. Exposed Ceiling. Exposed, open beam ceilings are where the underside of the roof decking ca be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not verloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. Oyu er/Agen SiSignature Date Contra or Signature Date Property Address I✓3 Permit Number Revised on 7/9/2009 LD;07/01/2015; Florida Building Code 6th Edition (2017) RECEIVED High -Velocity Hurricane Zone Uniform Permit Application Form JAN 3 1 2019 fdresSection A (General Information) s ermit No. Process No. oes Name ��' ( d l.,- ✓ �l'Gz _4r:K .... .. ROOF CATEGORY • • • • • • ""' ❑ Low Slope ❑ Mechanically Fastened Tile Mortar/A11111Ashre Set Tjle; • ❑ Asphaltic ❑ Metal Panel/Shingles Wood §6(Qies/Shake�' •. Shingles Are fliere '' •"' • • • • • • ❑ Prescriptive BUR -RAS 150 Gas INAt $tacks? • YOSLI No)k•••• • ROOFTYPE Type: Naturafp qLPGXLI ❑ New Roof P)Re-Roofing ❑ Recovering ❑ Repair ❑ Maintenance . ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) -4D- 2�S1� Zosr� Q Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly Identify dimensions of elevated pressure zones and location of parapets. -34 W741,9909-111 Tile Roof System MIAMI•DADE Miami -Dade County HVHZ Electronic Roof Permit Form Section D Tile Roof System "Delivering Excellence Every Day' Roof System Manufacturer: BORAL ROOFING, LLC Notice of Acceptance Number (NOA): t jQ " ()50qj4 • • • • Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): • • • • • 39.1 68.1 100.7 •••••' • P1: P2: P3: ,••• Maximum Design Wind Pressures, (From the NOA Specific system): 31.3 psf ...... Fill in the specific roof assembly components. If a component is not required, insert not applicable fr1/a�tnthe tewt boz Deck Type: -5/8" Plywood— .:. r Roof Slope: "/12" Roof Mean Height: 3 ft. Method of Tile Attachment: I -Adhesive, 2 Small Paddy Polyfoam Polypro-U� Alternate Method of Tile Attachment per NOA: Polyfoam Drip Edge Size & Gauge: 3" face 26 ga.— Drip Edge Material Type:—Galvinized Metal— Drip Edge Fastener Type: 1 1 1/4 ringshank nails 4 oc Hook Strip/Cleat gauge or weight: -n/a- Optional Insulation: • • • • Optional Nailable Substrate: Optional Nailable Substrate Attachment: Basesheet Type: 30 LB ASTM D-226 Fastener Type for Basesheet Attachment: 1 1/4 Ringshank nails 12 oc field 6 oc laps Tile Underlayment (Cap Sheet) Type: Bahe seal Tile Underlayment Attachment Method: F elf adhered Tile Profile: Boral saxony 900 flat the 71 Section E. IrCOUNTY Excellence Every Day" Miami -Dade County HVHZ Electronic Roof Permit Form Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based tile systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values A9 * 0 0 greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is actggtable. 0000 "' • • 0000.. 00 0000.. . 00000 . _ g: 7.62 31.3 q�yl� 000..0 P 1: 39.1 x .315 = 12.31 M = Mr1: 69 5 N • g:� � •0000• P2: 68.1 xx .315 = 21.45 _M 7.62 =Mr2: 13.83 < 31.3 �y�• •� " '•;••0 - 0 0 0000. 00 00 00000 Mg: = 24.10 31.3 ►t1090 00000 P 3: 100.7 X .315 _ 31 72 M :7.62 Mr3: 5 0000.. .900.0 Method 3 "Uplift Based Tile Calculations Per RAS 127" 0 • • • 00 0 0 00 0 0 • 0000 For Uplift based file systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. P1:x1: Symbol xw: Design Pressure P1 or P2 or P3 -W: Mean Roof Height xCos 0:F�=Fr1: 5 NOA F' P2:x1:�=�xw:�= Job Site Aerodynamic Multiplier Product Approval (NOA) -W:�=� Mg x Cos .: r7 = Fr2: <_ NOA F' P3:Ox1:�=�xw:�= Required Moment Resistance Mr Calculated Minimum Attachment Resistance F' Product Approval (NOA) Required Uplift Resistance -W:�=� Calculated Average Tile Weight xCos 0:F-1=Fr3:�<_� Product Approval (NOA) Tile Dimensions I = ll length w width Product Approval (NOA) NOA F' Where to Obtain Information to complete tile calculations Description Symbol Where to Find Design Pressure P1 or P2 or P3 Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional engineer based on ASCE 7. Mean Roof Height H Job Site Roof Slope 8 Job Site Aerodynamic Multiplier Product Approval (NOA) Restoring Moment due to Gravity Mg Product Approval (NOA) Attachment Resistance Mf Product Approval (NOA) Required Moment Resistance Mr Calculated Minimum Attachment Resistance F' Product Approval (NOA) Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval (NOA) Tile Dimensions I = ll length w width Product Approval (NOA) SCOPE: • • This NOA is being issued under the applicable rules and regulations governing the use of cquv4ction jate;ials. Thi: documentation submitted has been reviewed and accepted by Miami -Dade County RER - Broduct Conot S;Ction * *Dg* used in Miami -Dade County and other areas where allowed by the Authority Having Juris4itt�ptp . . • This NOA shall not be valid after the expiration date stated below. The Miami -Dade Cour Product Control Sectipp• • • (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right toga *e%bis ' • product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Saxony 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 16-0711.05 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Semino 0 NOA No.: 18-0509.17 MIAMI -DACE COUNTY Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 1 of 9 MIAMI•DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.ntiamidade.eov/economv Boral Roofing, LLC *00000 7575 Irvine Center Drive Suite 100 Irvine, CA 92618 • • • • • • • ...... . ...... SCOPE: • • This NOA is being issued under the applicable rules and regulations governing the use of cquv4ction jate;ials. Thi: documentation submitted has been reviewed and accepted by Miami -Dade County RER - Broduct Conot S;Ction * *Dg* used in Miami -Dade County and other areas where allowed by the Authority Having Juris4itt�ptp . . • This NOA shall not be valid after the expiration date stated below. The Miami -Dade Cour Product Control Sectipp• • • (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right toga *e%bis ' • product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Saxony 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 16-0711.05 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Semino 0 NOA No.: 18-0509.17 MIAMI -DACE COUNTY Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete Deck Tyne: Wood 1. SCOPE 0000 This NOA approves a system using Saxony 900 (Slate, Shake & Split Shakij •Eoperet % hoof Tile, •asp:' manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice o€Aoaeptanc4.' TAf locatjgtj: where the pressure requirements, as determined • by applicable Building Code, do ndtmew ed the design pressure , values obtained by calculations in compliance with RAS 127 using the values listed'iVthe in4allatipn sevtiori •: 0000 . 0000. herein. The attachment calculations shall be done as a moment based system. • ... 0000.. .. .0000 0000.. .. .. . 2. PRODUCT DESCRIPTION 0000.. ' • • • • • .' Manufactured by Test Product 0000.. 0000.. Applicant Dimensions Specifications DesMj;tion .. :'•"' Saxony 900 -Slate Length = 17" 0 TAS 112 Flat profile, interlocking, high-pressure0ex00truded Width= 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-5/32" batten, mortar set or adhesive set applications. Saxony 900 Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Split Shake Width = 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-9/32" batten, mortar set or adhesive set applications. Top surface produced with 4 different configurations: 1. Complete tile brushed 2. Right half brushed (shown in drawing) 3. Left half brushed 4. No brush Saxony 900 -Shake Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Width = 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-9/32" batten, mortar set or adhesive set applications. Trim Pieces Length: varies TAS -112 Accessory trim, boosted Barcelona, concrete roof Width: varies pieces for use at hips, ridges and rakes. varying thickness NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 2 of 9 2.1 MANUFACTURING LOCATION 2.1.1 Lake Wales, FL 2.2 EVIDENCE SUBMITTED: Test Agency Test Identifier The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies Atlanta Testing & Engineering, Inc. Celotex Corporation Testing Service Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. American Test Lab of South Florida 94-084 94-060A 25-7183-6 25-7183-5 25-7214-1 25-7214-5 Project No. 307025 Test #MDC -77 7161-03 Appendix II & III Letter Dated Aug. 1, 1994 P0631-01 P0402 R 1.894/R2.894/R3.894 Test Name/Report Static Uplift Testing TAS 101 (Mortar Set) .'. Static Uplift Testing , • �, TAS 101 (Adhesive Set)...:.. Static Uplift Testing TAS 1.W* • • (2 Quik -Drive Screws, Direct D tkj Static Uplift Testing TAS IU% (2 Quik -Drive Screws, Battew... Static Uplift Testing TAS M2 ' (1 Quik -Drive Screw, Direct Teck Static Uplift Testing TAS 102 • (1 Quik -Drive Screw, Battens) Wind Driven Rain TAS 100 Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Physical Properties TAS 112 520109-1 Static Uplift Testing 520111-4 TAS 101 520191-1 Static Uplift Testing TAS 101 Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Calculations Evaluation Calculations RT0617.04-16 25-7094 25-7496 25-7584/25-7804b-8/25-7804-4 & 5 25-7848-6 25-7183 Aerodynamic Multipliers Two Patty Adhesive Set System Restoring Moments Due to Gravity TAS 112 Date , may 1994 6006 000000 Paid, 1994 ' 6666.. .Feb..1995: •' • •: 00 06: • 000 6Eeb..1995 6666. • .60006 .Marph, 199.%.::, 0.06.. :Njaeh, 199x" 6.06 Oct. 1994 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Aug. 1994 Dec. 1998 March 1999 February 1996 April 1996 December 1996 March 1995 09/01/16 April 1999 09/01/16 06/29/16 NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 3 of 9 PRI Construction Material COPO-002-02-12 TAS 101 10/12/2016 COPO-002-02-06 TAS 101 10/12/2016 COPO-002-02-05 TAS 101 10/12/2016 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in a(;rgr&nce with TAS 106.• 0000 • 0000.. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laborato" tooperfo;m quarterly test' in accordance with TAS 112, appendix `A'. Such testing shall be submrtied't.'o the' Building Civde % 00.09. Compliance Office for review. 00,00 0 .. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applicdtions'50000 V*rds listed • section 4.1 herein. 96:09: 9 0 • • 0000. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular tb'thVroof slope unless stated.. 9 999. � otherwise by the underlayment material manufacturers published literature. 9 0 0 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be intnpkance with' the applicable Building Code. • • 0 .. • • • • • • .00 4. INSTALLATION 4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w) Tile Profile Weight -W (lbf) Length -I (ft) Width -w (ft) Saxony 900 Slate, Shake & Split Shake 10.9 1.417 1.08 Table 2: Aerodynamic Multipliers - X (ft3) Tile % (ft3) X (ft3) Profile Batten Application Direct Deck Application Saxony 900 0.291 0.315 Slate, Shake & Split Shake Battens Direct Deck Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile Profile 2":12" 3":12" 4"•12" 5":12" 6"•12" 7":12" or greater Saxony 900 Slate, Shake & Direct Deck Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Split Shake 7.70 7.62 6.61 7.50 6.48 7.34 6.31 7.16 6.13 6.95 NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 4 of 9 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Fastened Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile Saxony 900 Slate, Shake & Split Shake (min 15/32" (min. 19/32" 4 Medium paddy placement of 24 grams of Polyset® AH -160. 594 plywood) plywood) 3. ICP Adhesives Polyset® AH -160 two -component foam, minimum weight per paddy 8 grams. Saxony 900 2-10d Ring Shank Nails 30.9 38.1 17.2 Slate, Shake & Split 1-10d Smooth or Screw Shank Nail 7.3 9.8 .. 4.9 Shake 2-10d Smooth or Screw Shank Nails 14.0 19%, • • 7.4.... 1 .#8 Screw 30.8 ' 30.8 • 18.2 2 .#8 Screws 51.7 7 24.4• • • • 1-10d Smooth or Screw Shank Nail (Field 24.3 4. 24.?••�• Clip).' 1-10d Smooth or Screw Shank Nail (Eave 19.0 ... 199 22.1":' 2-10d Smooth or Screw Shank Nails (Field 35.5 ...35.5 34. Cli •• • 2-10d Smooth or Screw Shank Nails (Eave 31.9 34.9 :" " 32.2 Clip) •• . ••••• Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Paddy Adhesive Set Systems Tile Tile Application Minimum Attachment Profile 40.4 4 Resistance Saxony 900 Slate, Shake & Split Shake Adhesive' 31.3 2&3 4 Medium paddy placement of 24 grams of Polyset® AH -160. 594 1 See foam adhesive manufacturer's component approval for installation requirements. 2 The Dow Chemical Company TileBond' one -component foam minimum weight per paddy 13.9 grams. 3. ICP Adhesives Polyset® AH -160 two -component foam, minimum weight per paddy 8 grams. 4. DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Saxony 900 Slate, Shake & Split Shake ICP Adhesives Polyset® AH -160 Two -component foam DAP Products Touch N' Seal Storm Bond 2 two -component foam 118.9 3 40.4 4 935 45 6 3 Large paddy placement of 45 grams of Polyset® AH -160. 4 Medium paddy placement of 24 grams of Polyset® AH -160. 5 Large paddy DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 45 grams. 6 Medium paddy DAP Products Touch N' Seal Storm Bond 2 two -component foam minimum weight per paddy 24 grams. NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 5 of 9 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Tile Minimum Attachment Profile Application Resistance Saxony 900 Slate, Shake & Split Shake Mortar Seth 43.96 • 0 • • 0 • .. .. . 0000 0000 7 Tile-Tite Roof Tile Mortar .. • 0000.. . 0000.. 000:0. 5. LABELING 0000.. 0000 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer'S•Aame or logo• ns detailt d• ed: 0 below, or following statement: "Miami -Dade County Product Control Approv•: : 0 0 0: 0 • 0 • • 0 • .. .. . 0000.. • 0000.. 0 . . . . 0000 .. 000000 0.0 .0000. . 0 0000 LABEL FOR BORAL SAXONY 900 TILES (LAKE WALES FL PLANT LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWINGS NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 6 of 9 NAIL HOLES UNDERLOCK I SAXONY 900 - SLATE i.. . . ,542" (Slat 0000.. MVERL,CD L ..... .. . 0000 0000.. 0000.. .0000. NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 7 of 9 NAIL HOLES PROFILE DRAWINGS Note: Available Top Surface Finishes 5. Complete tile brushed 6. Right half brushed (shown in drawing) 7. Left half brushed 8. No brush SAXONY 900 - SPLIT SHAKE NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 8 of 9 .... ...... gjke) �1-9/31v see 0 ..... • ..... . 06006 • . .. . 000* NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 8 of 9 NAIL HOLES G PROFILE DRAWINGS SAXONY 900- SHAKE END OF THIS ACCEPTANCE 1-9/3;.".Make) NOA No.: 18-0509.17 Expiration Date: 04/26/22 Approval Date: 08/02/18 Page 9 of 9 MIAM% MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economy ICP Adhesives and Sealants, Inc. 12505 NW 44" Street Coral Springs, FL. 33065 ••.• SCOPE: ••• 0009 9.9••0 This NOA is being issued under the applicable rules and regulations governing the use of consTructi&b aulterials. This. documentation submitted has been reviewed and accepted by Miami -Dade County RER-l;>:gcct Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).. ; • • • •; This NOA shall not be valid after the expiration date stated below. The Miami -Dade Coypu k1oduct Uoiltrol SeMM . (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve.tht.4ght to Aatt*this pr9dyit0 or material tested for quality assurance purposes. If this product or material fails to perfor"iti-the accepted manner, the' manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or � Igsr nd theme • of such product or material within their jurisdiction. RER reserves the right to redbke. this acceptance, determined by Miami -Dade County Product Control Section that this product or material fails to meet the•raquirerhents • of the applicable building code. 000. 00 This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset® AH -160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset' AH -160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Radfing. Application Standard RAS 127. For use with approved flat, low, and high profile roof tile ;.v.s rns using TP Adhesives Polyset® AH -160. 00000: ; • • • • • ...... 0000.. PRODUCTS MANUFACTURED BY APPLICANT: • 0 • 0000 Product Dimensions Test ProduaOAascription . 0000. Specifications • • • • ...... ICP Adhesives N/A TAS 101 Two component pplyttrithanq foam adhg,i; e • Polyset'AH-160 . 0000.. ICP Adhesives Foam N/A Dispensing Equipment • Dispenser RTF1000 • ICP Adhesives ProPack' N/A Dispensing Equipment 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset' AH -160 roof tile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Proper Test Results Density ASTM D 1622 1.6 lbs./ft.' Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft2 Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -40'F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 MiAMI-DAne COUNT r Expiration Date: 05/10/22 01 losigApproval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-1PA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB -589-631 . . ASTM D 1623 • • .... ...... .02/01/94 . • Polymers Division ...... . ...... Ramtech Laboratories, Inc. 9637-92 ASTM E 108 . b430/93 • .... .. .. ..... Southwest Research Institute 01-6743-011 ...... ASTM E 108 ..'..' . . ..... ;'I llt6/94 01-6739-062b[l] ASTM E 84 • • • • • . 01116/95 .' . . . ...... .... % Trinity Engineering 7050.02.96-1 TAS 114 .'. '03/14/96 P36700.04.12 ASTM D 1623 : 04/19/12 ' P39740.02.12 TAS 101 02/11/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset' AH -160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH -160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset' AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. • • 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance witVgoofingAllplicaticm••;• Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Mairitenancs BALklet. ...... . ...... 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed yICP Adhesives and. Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicat(MV the 4tthprty having • .... .. .. . jurisdiction. ....• ...... . . ..... 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment i9 iegvired berore application... of any adhesive. The mix ratio between the "A" component and the "B" component $hftr•lZe maintained between . . . . ...... 6. ICP Adhesives Polyset' AH-160 shall be applied with ICP Adhesives Foam Dispensor.12Tfi 1004 or ICP •' • Adhesives ProPack® 30 & 100 dispensing equipment only. • • • • 7. ICP Adhesives Polyset® AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset® AH -160 has been dispensed. 9. ICP Adhesives Polyset® AH -160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches " ", • .3Q • • High Profile #2 17-19 sq. inches • •3�• '. .. ... . ..... Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at • • • 12 gramg,per paddy head of tile 9-11 sq. inches of '" • .... overlap .. .. ..... •�••�� �•�•� Two-Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudingr •' 17 gams per bead • •; edge)20-25 sq. inches eac� ••� '� bead •••••• '•��� • Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 A.Tjlmder pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 H a throtr n astk tarnont u+y 4rbraquireM. �,-W�d (BanaxnT�a9 \ as 1rt 04" ns options E Y*Counl-44 40, 21n n `' 1r E•ti• Closuni Nall throughpbstic oement -,when required) `'�.. wdwy��rtaen.ra�i v0dwti.yrt+.sye I to in.x`ti. 2lfLwidb "A Bu tens option., Ca'r! Closure Law* Coume — Pasch NA through pl•ule mow. (ren required { Prd�r i$}hathilvl 2 tn,wGda f/ IN, Baftens Fula Weepholk ." ✓ k. Em closure loin in. � Drip APPROVED Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manger. Insure apP*m �imately 17 (109.7 cm2) — 23 (148.4 �2)$quarg mc$ adhesive • • •••! • contact with the undersitlaafet• he ti !!.!•• .... •• •• ..... •••••• • • ••••• •• •• • •••••• • Medium Profile/ Doubl&Pan File •••••• 1. Starting at the eave court, apply a"fli'tpum Tv • (50.8 mm) x 10" (254 mm) x 1" (25*4Mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 pPa1ft ughp4tsiccsm.n4 P6ddyf5"#& ST4#) twhen reau%ad� " �r FawCoursa, fi r` F.isda Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) - 23 (148.4 cm2) square inch adhesive contact with the 6666 underside of the tile. • • 0600 6660•• 2. At the second course, appLXajinim1:!-'T50.8mm; x 7" (177.8 mm) x 1" (25.44m) foam paddy onto the . 6666.. underlayment positioned.WA%wn uilder6tlT • strengthening rib closest td IN overloffl of the tilt % being set. • • • • • . 6 6666. .. .. . 666.•6 6666.. 3. Continue in same mannel. IrWe approximately 14':.:. (64.5 cm2) - 12 (77.4 cmJ square inch S(Wesive • 6666.. contact with the undersideaf the the: 6 • • 6 • Medium Profile / Double Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) - 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Ala dwough pZistk copeart rvAanraipulrodl y Paddy [B-iiATilog 8aeons optional Rave Course —Fascia W.phcb+ 1 O 1n. 21n. '` Fave doswe Drip ad -go High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive WIM with the .0000 underside of the tile. . 0. 0000.. 0000.. . 0000.. 2. At the second course, appLX$ilainimum 2" (50.8rpm) • x 7" (177.8 mm) x 1" (25.4-mtn) foarpopaddy onto IN • underlayment positioned w0hown under the pan • • • • • portion of the tile closest t%=overlbckjfthe till• • • • being set. .. .. . 0000.. 0000.. . . . . 000 3. Continue in same manner. Insure aplkb Mi'ately L7"0.. (109.7 cm2) - 19 (122.6 cri ;r s4uare inch•adhesivio • • • • contact with the underside of the tile. • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 Mail through plastic cement Paddy (between tiles) (when required) Battens optional ° Paddy iunder tile) single paddy on top of the { �; 4x 4 IrL rnrngg te I er single paddy on uoderla ,�• "� 2 x 4 toi Fascia in. Eav+e closure Flat/Low Profile Tile Na(lthrough plastic eement Single paddy under tile (when required) Paddy ibetween tiles) Battens Paddy(undertle) optionaI Singled -� on topo�ft�lle� �4x4in. 2x4in."-, single paddyon tKnHateMm ymeut loin. 2In. Eave Closure Lwe Course Fascia Medium ProflleTlle On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (10 1.6 mm) up from the eave edge free of foam to prevent the a xpalided adhesive from blocking the wegp hpies. Insure• • • • • • • approximately 17-23 it?109.7-1,WjU2) of •• adhesive contact withWilriderside of the tile """ •••• •• •• ••••• Apply a 4" (101.6 mmx4:'4101.6 mm) x 1" mm) foam paddy onto 4e- 4iderlayment*just bekrw: • the second course lin$PdCitibned foarft paddy •. under the strengthenin.g rib for flaCk1* or under the pan portion of the tile,- jjuse:t to tl*e uji&rlocl,frx• • the second course tile to be insta118d: J Sure approximately 8-9 int (51.6-58.1 cm2) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nall thwagh plastic Single paddy under tile (when required) Paddy (between tiles) Battens !optional } Paddy(undertilel 1' Sirgfepaddy-• un underta ; 4 x 4 in.� Single 2 x4 in. on top of file to w Eare Course�"T asda Weephole loin. Eave closure Drip edge High Droflle Tile 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x3/4 (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm2) square inj4,Aohesive contact with the underside of the d 1g.Whe overj�o.. and 7 (45.2 cm2) - 9 (58.4•crL2) square inch . adhesive contact with -the pidersi& o� the tile at • • • • the head of the tile. CdiiAAM in same fnanner. ; .... •• •• • •••••• • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 1) Place enough adhesive to achieve 6S to 70 sq. in. Steep pitch applications In contact with the pan tile. (when required) 2) Turn covers upside down. Place adhesive in to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25 sq. in. contact area. Underlayment' Y' C '/ o Sheathing 4� Eave closure ` (motar shown) Weephole Fascia Board Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eave ernd of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile APPROVED Two Piece Barrel (Cap and Pan) Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive li" a chance to cure. .... ...... ..... Continue in same ma.nnero ringing. two• • pan... . 00 r00•• • courses up toward the JAge. Insure :6066 approximately 65 (4%%40n2)—17A.C431.6 crrlj) .. square inch adhesive cpfAact with the.undersiide'. • • -)0000• of the pan tile. • • • • • 000000 • 0000•• • • Turn covers upside sown exposmgtle.underside • • of the tile. Apply a ri>ajri�n m 1" (25.4 mm) i 41Wo; (254 mm) bead of adhesive diree4p"f the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 •• " • • SCOPE: ...... . ...... This NOA is being issued under the applicable rules and regulations governing the use of cohAtt Mion materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - I'mMUT Contrcr Section to;;; • used in Miami Dade County and other areas where allowed by the Authority Having Jurisdi • • • g HJ . • • 00 go ...... This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Pxp&ct Contrgl Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the rigit to have this • product or material tested for quality assurance purposes. If this product or material fails to per form int a accepted . • • manner, the manufacturer will incur the expense of such testing and the AHJ may immediatet� retoke, Qigoify, or • suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: BORAL TileSeal LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This new NOA consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. —^ NOA No.: 18-0502.03 MIAMI -DAD; COUNTY Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 1 of 4 M IAM I•DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Boral Roofing LLC. 7575 Irvine Center Drive, Suite 100 Irvine CA 92618 0000 • •• " • • SCOPE: ...... . ...... This NOA is being issued under the applicable rules and regulations governing the use of cohAtt Mion materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - I'mMUT Contrcr Section to;;; • used in Miami Dade County and other areas where allowed by the Authority Having Jurisdi • • • g HJ . • • 00 go ...... This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Pxp&ct Contrgl Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the rigit to have this • product or material tested for quality assurance purposes. If this product or material fails to per form int a accepted . • • manner, the manufacturer will incur the expense of such testing and the AHJ may immediatet� retoke, Qigoify, or • suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: BORAL TileSeal LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This new NOA consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. —^ NOA No.: 18-0502.03 MIAMI -DAD; COUNTY Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS PRODUCTS DESCRIPTION: Trinity ERD BRLRF-SC16810.11.17 ASTM D 1876 11/28/17 NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 2 of 4 Test Product Product Dimensions Specification Description . . . . ..96 •00000 BORAL TileSeal 36" x 36' rolls TAS 103 SBS self -adhering asphalt sheet material with a . • 36" x 72' rolls ASTM D1970 0000.. white glass re -enforced *plZ�ester surfacing fabriq • : • for use as an underlayme.m sloped roof • 0000.. ... assemblies. ' 0000 Boral Citadel Plus 36" x 72' rolls ASTM D1970 ..9... • SBS self -adhering aspkak0eet moft"al with a 9696.• poly film -facer; for use•as-a mid -ply underlayment. • in sloped roof assemblies. 0069:0 6 MANUFACTURIGN LOCATION: . 0000.. • • • . 6 • 0 0 •„� • 6 1. Brentwood, NH. 2. Houston, TX. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials OCF-356-02-04 ASTM D1623 07/25/18 Technologies, LLC. OCF-356-02-02 TAS 103 07/24/18 OCF-356-02-01 ASTM D1970 07/26/18 OCF-424-02-04 ASTM D1623 07/25/18 OCF-424-02-01 ASTM D1970 07/25/18 OCF-424-02-03 TAS 103 07/25/18 Trinity ERD BRLRF-SC16810.11.17 ASTM D 1876 11/28/17 NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated Deck Description: 15/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. Base Sheet: One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. ."". Ply Sheet Apply one layer of Boral Citadel Plus over Base sheet as per current sppsoval. ; ""' • (Optional): • • • • • • • .... ...... Membrane: One or more plies of BORAL TileSeal Underlayment with a minimus' head lap and "; • • minimum 6" end lap. Place the first course of membrane parallel tothtetve, roiling the membrane to obtain maximum contact. Remove the release membmne a&the membrane is • applied. Vertical strapping of the roof with BORAL' TileSeal Underlayment is it c eatable. Ali.:. end laps and laps without black selvage area shall be sealed under lap us'iag an SBS modifi(;4 • mastic.• .... Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps. No nails or tin caps shall be exposed. Surfacing: Approved for Adhered Roof Tile using TILE BOND or AH -160, Mechanically Fastened Roof Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies. NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 3 of 4 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but ipay be applied over a roofing Base/Anchor sheet underlayment. ' 0000 • � 0000.. 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer Il an 180 da3t%Qf:. •, application. 00.0.0 0000.. • 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 whejr tiia s are loaded directly" • • • to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitMeVgreater than 6:12".•.. •. 0 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed apprpyal pf this }� punct with" • 0000.. specific prepared roofing products. • 8. Tiles shall be stored on battens on roof pitches greater than 6:12". 00 0 • 0000.. 9. BORAL TileSeal underlayment may be used with any approved roof covering Notice ofACc4)tancg lisl;ng :0000: BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If MML 0 TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment shall be applied over the underlayment, and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below END OF THIS ACCEPTANCE NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 4 of 4