Loading...
RC-18-2494 (2)Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Permit NO.: RC -9-18-2494 Permit /VR Number: 634604 '^ Q � Permit Type: Building (Residenti4l) 11�i=)M-nj1j Work Classification: Alteration Permit Status: Approved issue Date: 10/15/2018 Expiration: 03/18/2019 Location Address Parcel Number Project 55 NE 100 ST, Miami Shores, FL 33138 1132060131420 <NONE> Contacts MICHAEL & DOROTHY ESSINGTON Owner MICHAEL & DOROTHY ESSINGTON Applicant 55 NE 100 ST, MIAMI SHORES, FL 33138 55 NE 100 ST, MIAMI SHORES, FL 33138 SPAZIO HOME INC Contractor JUAN CARLOS ORRIOLS 7715 NW 56 ST, DORAL, FL 33166 Business: 3055824488 Inspection Requests: Description: REMODEL EXISTING KITCHE=SAME ION. Valuation: $25,000.00 305 762 4949 REMODEL EXISTING BATHROOM IN EXIS Total Sq Feet: 157.00 Fees Amount CCF $15.00 Cert. of Compl. for Single Fam and Duplx $50.00 (Manual) $200.00 CO/CC Fee $50.00 DBPR Fee $11.25 DCA Fee $7.50 Education Surcharge $5.00 Notary Fee $5.00 Permit Fee $750.00 Scanning Fee $24.00 Technology Fee $20.00 Total $937.75 Building Department Copy Payments Date Paid Amt Paid Total Fees $937.75 Credit Card 10/15/2018 $737.75 Check # 560 09/19/2018 $200.00 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoi i ation is cc ate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore uthorize the ove a d contractor to do the work nstat5 Cow Authorized Signature: Owner Date October 15, 2018 Page 2 of 4 1, Miami Shores Villa aG g 1 S � Building Department g 2018 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 BY• Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 201:4 BUILDING Master Permit No.V-o-((g- '24 q PERMIT APPLICATION Sub Permit No. BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑ RENEWAL PLUMBING ❑ MECHANICAL PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION [:] SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 55 P— I oto SiVL� City: Miami Shores County: Miami Dade zip: 3313 Folio/Parcel#: 1 J*5 201, 01Is the Building Historically Designated: Yes NO � Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): i *V011Phone#:Mb*z.77G' 1jb-") Address:, _gr,- ) Oo Jl l i - City: m j ant i 5 ho.Im State: Zip: 3313 8 Tenant/Lessee Name: Phone#: � 7 r Email: tf i f�f1Ar _1 P 1 Ss 116444-1 0L CONTRACTOR: Company Name: aZi 0 Cn n' Yq C-+;z>n Phone#: f 57 -,*A,54 - CTA I Address��T City: ,► "& N State: F -I- Zip: -43! Qualifier Name: �5 CQf LD►' G► Phone#: 95't -.SS14 - Oµ Q/ State Certification or Registration #: t= •n.C. i L-4> 1 J `-'1 Certificate of Competency #: DESIGNER: Architect/Engineer: 8 ZPhone#: Address: ��) N W 3 Z"d Gk' , City: M State: 'IF L Zip: 21.3o b 3 Value of Work for this Permit: $ of 6i D Dfio Square/Linear Footage of Work: 116 Type of Work: ❑ Addition Alteration ❑ New ❑ Repair/Replace ❑ Demolition p i rl ' SCLVne. LOC Q� l9n Descri tion of Work: A1C. ��i-i'nA �(o VY►n.lal OV i G•i-f�n In n�fVe\.n.i,i1 i ✓� o.i tL%i-��./1 A � A /•w �'1� Ll ./1' Specify color of color=thru tike ' Submittal Fee-$ Pe'rmit,fee" Scanning Fee $ Technology Fee $ Structural Reviews $ (Revised02/24/2014) Sy CCF $ CO/CC $� C'J Radon Fee $ DBPR $ Notary $ Training/Education Fee $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ 3-:--? - 4 Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. , , _ "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY Y RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR -PROPERTY. IF YOU• INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated valpe exceeding $2500,, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. r SignatureM&4�(2 Signature OWNER r ENT The foregoing instrument was acknowledged before me this dayof ' ..�r'20 by `�2Sli'C`� �L�SI (c ►.11o1�r? who is personally known to CONTRACTOR The foregoing instrument was acknowledged before me this day of -540 r 20 )R , by ` l ipt4 OJSS ()P -0J o ho is personally known to me or who has produced VD5ZCy\"'� as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: \`��y0i111(►11► NOTARY PUBLIC: is Signz Sign: _ Print: =_Z' o°" y; Print: • &54760 Seal: %99�'__%ry°,nN o�� Seal: SINDIA ALVAREZ Z/C ..... OFA �(3\\ a MEXP REST September 3?20223 '••:�oF F�R•� Bonded Thm Notary Public Und..dte. ****************************** ************************************************************************** APPROVED BY w Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Property Search Application - Miami -Dade County Page 1 of 2 ­ OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: Property Address: 11-3206-013-1420 55 NE 100 ST Miami Shores, FL 33138-2314 Owner MICHAEL P ESSINGTON &W DOROTHY S ESSINGTON ..........__........ _.__ Mailing Address 55 NE 100 ST MIAMI SHORES, FL 33138-2314 PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY : 1 UNIT Beds / Baths / Half 3/2/0 Floors 1 Living Units 1 Actual Area 1,919 Sq.Ft Living Area 1,919 Sq.Ft Adjusted Area 1,761 Sq.Ft Lot Size 11,500 Sq.Ft Year Built 1938 Assessment Information Year 2018_! 2017 2016 Land Value $287,615 $287,615 $287,615 Building Value $120,397 $120,591 $120,785 XF Value $3,992 $4,039 $4,087 Market Value $412,004 $412,245 $412,487 ......................... _._ Assessed Value .............. $186,684 _..__. $182,8451 $179,085 Benefits Information Benefit Type 2018 2017 2016 Save Our Homes Assessment $225,320 $229,400 $233,402 Cap Reduction Taxable Value $161,684 $157,8451 Homestead Exemption $25,000 $25,000 $25,000 Second Exemption $25,000 $25,000 $25,000 Homestead Exemption Value $50,000 $50,000 $50. Taxable Value $136,684 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). IShort Legal Description MIAMI SHORES SEC 1 AMD PB 10-70 LOT 18&E1/20FLOT 17&W1/2 OF 19 BLK 10 LOT SIZE 100.000 X 115 OR 18087-3796 0498 1 https://www.miamidade.gov/propertysearch/ Generated On : 9/19/ Taxable Value Information 2018: 2017 ........... ....... ....... County Exemption Value 1 $50,000 $50,000 $50. Taxable Value $136,684 $132,845 $129. School Board Exemption Value $25,000 $25,000 $25 Taxable Value $161,684 $157,8451 $154. City Exemption Value $50,000 $50,000 $50. Taxable Value $136,684 $132,845 $129 Regional Exemption Value $50,000 $50,000 $50. Taxable Value $136,684 $132,845 $129. Sales Information Previous Sale Price OR Book -Page Qualification Descriptic 04/01/1998 $156,000 18087-3796 Sales which are qualified 03/01/1995 $76,000 16708-0688 Sales which are qualified 04/01/1988 -. ........ ._ __.._.... 02/01/1973 $62,000 ... --_.... -___ 1 $32,300 13658-0297 .............. __ 00000-00000 Other disqualified ..... Sales which are qualified 9/19/2018 Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 CONTRACTORS' REGISTRATION Fax: (305) 756.8972 IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR: A. XCOPY OF QUALIFIER'S STATE LICENCES B. - COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF LIABILITY INSURANCE* t � � r D. �� COPY OF WORKERS COMPENSATION INSURANCE* (Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit) IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY: A. COPY OF CERTIFICATE OF COMPETENCY OF QUALIFIER B. COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF STATE REGISTERED CONTRACTOR LICENSE OR MIAMI DADE COUNTY MUNICIPAL CONTRACTOR'S TAX RECEIPT. D. COPY OF LIABILITY INSURACE* E. COPY OF WORKERS COMPENSATION INSURANCE* (Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit) *YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE AS FOLLOW: Certificate Holder: MIAMI SHORES VILLAGE BLDG DEPT 10050 NE 2ND AVE MIAMI SHORES, FL 33138 Certificate must specify the description of operations or contractor license number. •ff!•/•■■ffttffffff■■/!tt/1 t/f!f■•///■■■i■■•■/■/t•ffttf•■■■•tf•f■■ff■/■/ft■•■■tf■■!//■•/ BUSINESS NAME: BUSINESS ADDRESS: T&0_r CITY 'befit STATE 6f ZIP 33 i tic. BUSINESS PHONE: (�'o �) '5— 92 �y R9 FAX NUMBER (_) CELL PHONE ( S~ E QUALIFIER'S NAME: e:,( S i3G 12-(o 16-19 QUALIFIER'S LIG NUMBER: RICK SCOTT, GOVERNOR JONATHAN ZACHEM, SECRETARY FI rich dL)pr STATE OF FLORIDA DEPARTMENT OF BUSINESS 1_I'jDnPI FESSIONAL REGULATION CONSTRU THE BUILDI PROVIS UNDER THE TUTES EXPIRATIMU-A. T � C1 -01-31,2020 Always verify licenses online at MyFloridaLicense.com Do not alter this document in any form. This is your license. It is unlawful for anyone other than the licensee to use this document. 005799 Local Business Tax Repcei t Miami—Dade County, State of Florida -THIS IS NOT A BILL - DO NOT PAY 7217173 BUSINESS NAME/LOCATION SPAZIO HOME INC 7715 NW 56TH ST DORAL FL 33166 L B T RECEIPT NO. RENEWAL EXPIRES - 7501377 SEPTEMBER 30, 2019 Must be displayed at place of business Pursuant to County Code Chapter 8A - Art. 9 & 10 OWNER SPAZIO HOME INC SEC. TYPE OF BUSINESS C/O JUAN ORRIOLS PRES 220 TANGIBLE PERSONAL PROP DLR PAYMENT RECEIVED BY TAX COLLECTOR Employee(s) 1 $75.00 08/02/2018 FPPU12-18-006254 permit, or a certification of the holder's qualifications, to do business. HoThis Local Business Tax Receipt only confirms payment of the Local Business Tax. The Receipt is not a license lder must com I or nongovernmental regulatory laws and requirements which apply to the business. Y with any The RECEIPT N0. above must be displayed on all commercial vehicles - Miami -Da a Code Sec 8a-216. Dial For more information, visit wM—w.miamidade.govAaxcollector A+C<> CERTIFICATE OF LIABILITY INSURANCE °��„`"” m THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIOHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If do certificate holder is an ADDITIONAL INSURED, the pollcy(las) must be endorsed. H SUBROGATION 13 WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement A staterneW on this certificate does not confer rights to the certificate holder In lieu of such endomement(s). PRODUCER Robert Gonzalez Insurance Agency, Inc 5220 South University Or Suite 105C Davie FL 33328 INSURED Spazio Home Inc 7515 SW 124th ST Gigi Rodriguez Florida Farm Bureau 954-680-9110 I Miami FL 33156 ; piMMF . J I rnVC0Ar_9:c r.F0TICI1%ATG MIJURFR• RFM_gWW A1111FIFR* THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSLIRANCEADOLSUOR POLICY EFF EXP Lam A COMMERCIAL GENERAL LIABILITY CLAIMS -MADE ® OCCUR X CPP 9525778 01/18t2018 01/18/2019 EACH OCCURRENT S 1,000,000.00 DAMAGEi T6RL�tf1_ e S 50,000.00 MED EXP ons S 5,000.00 PERSONAL a ADV INJURY 1 1,000.000•00 GENL AGGREGATE LIMIT APPLIES PER: POUCY El SECT F --]Loc OTHER. GENERAL AGGREGATE S 2,000,000.00 PRODUCTS-COMPtOPAGG S 2,000,000.00 $ A AUTOMoeaE LIABILITY " ANY AUTO ALLOWNED SCHEDULED HIRED AUTOS AUTOS NON -OWNED AUTOS AB 1340298 01/18/2018 01/16/2019 LIMIT S 300_000.00 BODILY INJURY (PK porton) S BODILY INJURY(P�aodderl) SAU --- $ s I UMBRELLA LIAROCCUR EXCESSLIAB CLAIMS -MADE EACH OCCURRENCE S AGGREGATE S DEC) I I RETENTIONS S WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETORIPARTNER/EXECUTIVE Ya OFFICERIMEMBER EXCLUDED? IMandatory In NH) II yos, d PcM wdw DESCRIPTION RATIOS S below NIA •R -�T -- E.L. EACH ACCIDENT S E.L. DISEASE -EA EMPLOYE $ E.L. DISEASE •POLICY LIMIT S i i DESCRIPTION OF OPERATIONS I LOCATIONS 1 VEHICLES (ACORD 101, Addltbnal Remarks Schedule, may be atachsd it mon space Is required) CERTIFICATE HOLDER IS LISTED AS ADDITIONAL INSURED SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE ?MILL. BE DELIVERED IN Miami Shores Village Bldg Dept ACCORDANCE WITH THE POLICY PROVISIONS' 10050 NE 2nd AVe AUTHORIZED REPRESENTATIVE Miami Shores, FL 33138 A- W 19W-ZD14 AGVKD GVKPUKA i nm, All rlgnls reserves. ACORD 25 (2014101) The ACORD name and logo are registered marks of ACORD ion w� JEFF ATWATER CHIEF FINANCIAL OFFICER STATE OF FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION * * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law. EFFECTIVE DATE: 2/14/2017 EXPIRATION DATE: 2/14/2019 PERSON: ORRIOLS JUAN C FEIN: 814646179 BUSINESS NAME AND ADDRESS: SPAZIO HOME INC 7515 SW 124TH STREET PINECREST FL 33156 SCOPES OF BUSINESS OR TRADE: LICENSED BUILDING CONTRACTOR Pursuant to Chapter 440.05(14), F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this section may not recover benefits or compensation under this chapter. Pursuant to Chapter 440.05(12), F.S., Certificates of election to be exempt... apply only within the scope of the business or trade listed on the notice of election to be exempt. Pursuant to Chapter 440.05(13), F.S., Notices of election to be exempt and certificates of efection to be exempt shall be subject to revocation if, at any time after the filing of the notice or the issuance of the certificate, the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a DFS-F2-DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 08-13 QUESTIONS? (850)413-1609 MIAMI.DADE vIL�N1I-JAllI CUUN'IX MRPRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC EE 11805 SW 26 Street. Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE ( www.miamidade.gov/economy Eco Window Systems, LLC Vi'• 8502 NNW 80 Street Medley, FL 33166 SCOPE: This NOA is being issued under the applicable ru emulations governing the use of construction materials. The documentation submitted has been rev ed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (A14J). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) anti/or the AHJ (in areas other that. Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AJIJ may immediately revoke, modify, or suspend the use of such product or material withijl their jurisd%g4.* RLR• ..... reserves the right to revoke this acceptance, if it is determined by Miami-Dade'Ceunty Proeluct Control Section that this product or material fails to meet the requirements of the applicable•l,• kr kng coce,: • • • *00*:* This product is approved as described herein, and has been designed to comply 'Mi" ilfe Florida -Building: • • • • Code, including the High Velocity Hurricane Zone. • • • • • • � • • • � • • • DESCRIPTION: Series "Eco -Guard 200" Aluminum Horizontal Rolling Wintjgly, � � .M.I, � � , � � � � • APPROVAL DOCUMENT: Drawing No. W09-12, titled "Eco -Guard Series-200•Alinn Horiz".e.Uiuig *--o:* Wdw. (L.M.I.)" sheets I through 7 of 7, dated 02/24/09. with revision F dated 10,1IM*7.* prepared b}+AI- •, Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miarui-D'ade Cdunty ErAckkl **9669 Control Revision stamp with the Notice of Acceptance number and expiration date %, t[iami le�-Dade :0009: County Product Control Section. • • • MISSILE IMPACT RATING: Large and Small Missile Impact Resistant L-BELING: Each unit shat bear a permanent label with• the manufacturer's name or logo, city, state, model/series. and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, andior manufacture of the product or process. Misuse of this NOA as an endorsement of ary product, for sales. advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall he provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 15-0728.05 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Sifang Zhao, P.E. 2. t NOA No. 17-1102.23 G'e r✓`�f �� Expiration Date: May 27, 2019 Approval Date: January 11, 2018 Page I Eco Window Systems, LLC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA#09-0312.08) 2. Drawing No W09-12, titled "Eco -Guard Series -200 Alum. Horiz. Rolling Wdw. (L.M.I.)", sheets 1 through 7 of 7, dated 02/24/09, with revision F dated 10/19/17, prepared by A]-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202--94 2) Large Missile Impact_ Test per FBC . TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 4'y Forced Entry Test. per FBC 24113.2.1, and TAS 202-91.0 along with marked -up drawings and installation diagram of an aluirinum 1io6iodta1 sliding window, prepared by Fenestration Testing Laboratory, inc.,Vest RgpQrt•Nlo. FTU -7635, dated 12/09/ 14, signed and sealed by Marlin D. Brig' 907P.E. 0900 (Submitted unde;,K4. #14-0,31 �V-1) 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94.0.009 ;00.00 2) Uniform Static Air Pressure Test, 'Loading pmvFBC TAF, 28i-94 3) Water Resistance Test, per FBC, TAS 202-94 • • •' • • 4) Forced Entry Test, per FBC 2411 3.2.1, TAtONN94 along with marked -up drawings and installation diagram of a %OX alumin:Ait• e • horizontal sliding window, prepared by Hurricane Engineering B:.Teaeting, huL.,.Test Report No. HETI-08-2226A, dated 01/15/09, signed and sealed by CandiJo e e ont, P.E. (Submitted tinder NOA#09-0312.08) 3. pest reports on: 1) Large Missile Impact "nest per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading, per FBC, TAS 203-91t alone with marked -up drawings and installation diagram of a XOX aluminum horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HE1'1-08-2226B, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under AOA#09-0312.08) 4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 along with marked -up drawings and installation diagram of a XOX aluminum horizontal sliding window, prepared by Hurricane Engineering & Testing, Laic., Test Report No. HETI-08-2227, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under NO4#09-0312.08) E-1 0000. 0000. 0000.. 0000.. 0000.. Sifang Zhao, P.E. Product Control Examiner NOA No. 17-1102.23 Expiration Date: May 27, 2019 Approval Date: January 11, 2018 Eco Window Systems, LLC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 5. Test reports on: 1) Air Infiltration Test. per FBC, TAS 202-94 2) Uniform Static Air Pressure Test. Loading per FBC TAS 202-94 3) Water Resistance Test, per FISC, TAS 202-94 4) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of a XOX aluminum horizontal sliding'Window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-08-2228A, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under 2V0.4 #09-0312.08) 6. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC.. TAS 203-94 along with marked -up drawings and installation diagram of a XOX aiuminu"•• horizontal sliding window, prepared by Hurricane Engineering.& Testing, inc,.-lest Report No. HETI-08-2228B, dated 01/15/09, signed and sealel-b d6dit t- Font, P.E. (Submitted undeeAld4"9-037708) 7. Test reports on: 1) Large Missile Impact Test per FBG TAS 201 �� • • 2) Cyclic grind Pressure Loading per FBC, TAN. "V) 94 along with marked -up drawings and installation diagram of a X40'4c4uminuun•. horizontal sliding window, prepared by Hurricane Engineering'& Ttdsting, Iht!,'Test Report No. HETI-08-2229, dated 01/15/09, signed and sealed VveteaLdido F. cont, P.E. (Submitted under•ND,J 409-f1.1.2• 86) S. Test reports on.: 1) Large Missile Impact Test per FBC, TAS 211$4: .. . . . 2) Cyclic Wind Pressure Loading per FBC. TAS 203-94 • • • along with marked -up drawings and installation diagram of a XOX aluminum horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-08-2230A, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under NO_4409-0312.08) 9. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, 'IAS 203-94 along with marked -up drawings and installation diagram of a XOX aluminum horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-08-2230B, dated 01/15%09, signed and sealed by Candido F. Font, P.E. (Subtritted under N0,4#09-0312.08) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 5r' Edition (2014), dated 07/08/15, complying with FBC 6" Edition (2017), dated 10/12/17 prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies with ASTM E1300-09 11 Sifang Zhao, P.E. Product Control Examiner NOA No. 17-1102.23 Expiration Date: May 27, 2019 Approval Date: January 11, 2018 E-2 Eco Window Systems, LLC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. NIATERLAL CERTIFICATIONS 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their "Trosifol@ Ultraclear, Clear and Color PVB Interlayers" dated 01/19/17, expiring on 07/08/19. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas� (Clear and White) Glass Interlavers" dated 06/25/15, expiring on 07/04/ 18. F. STATEMENTS 0060 1. Statement letter of confonnance, complying with FBC 51'' Edition (2014), with JXC 6'h ..... Edition (2017). and of no financial interest, dated October 1271417-prepgr�d•�y Al- •� Farooq Corporation, signed and sealed by- Javad Ahmad- P.E. """ • • • • • • • • • • 0000•. 0000.. 0000 • • •00.00 G. OTHER 0000 99.90 1. Notice of Acceptance No. 15-0728.05; issued to Eco Window 5_-flie�.s, LLC feytheir 9000.' Series "Eco -Guard 200" Aluminum Horizontal Rolling Windov- L'1\41".•3�?1hUved 06.9;9 on 09/03/15 and expiring on 05/27/19. ' . . . . 0000.. 0000.. 0 . 0000.. •. • �4,q Uk Sifang Zhao, P.E. Product Control Examiner NOA No. 17-1102.23 Expiration Date: May 27, 2019 Approval Date: January 11, 2018 E-3 72" WINDOW WIDTH 3 1/2" MAX. HEAD/SILL3 CORNERS I I 1 �I �I 111" WINDOW WIDTH (2) ANCHORS AT MTG. STILE ENDS TYP. (4) ANCHORS REQD. FOR SIZES AND LOADS MARKED WITH ';' ON SHEET 2 ONLY N 10 5/8" MAX. 4" 4" xm W 3 1 /2" MAX. HEAD/SILL 3" Mw ZHEAD/SILL q CORNERS ¢ 0 ;n � o CORNERS 3 ,o v --r-I�� it li II II DOW CORNING 899 a I I I 4 / I it I; ===!I 1c -- = g, C c \ II II M 0 '� M = n 0 l li =-�T-LJ m LO z n II II II Z 7 II I I > II � II I I �I 111" WINDOW WIDTH (2) ANCHORS AT MTG. STILE ENDS TYP. (4) ANCHORS REQD. FOR SIZES AND LOADS MARKED WITH ';' ON SHEET 2 ONLY N 10 5/8" MAX. 4" 4" xm W 3 1 /2" MAX. HEAD/SILL 3" Mw ZHEAD/SILL q CORNERS ¢ 0 ;n � o CORNERS 3 ,o v --r-I�� it li II II DOW CORNING 899 a I I I 4 / I a 'v)0 m ===!I 1c -- = 11--- C c \ W \ --IL �_� _- I--- 7) M MM t - l li m LO z n II II II Z 7 II I I 3 I � FALSE MUNTINS 31 1/4" 32 3/4" I FALSE MUNTINS (SURFACE APPLIED) (SURFACE APPLIED) MAY BE USED D.L. OPG. D.L. OPG. MAY BE USED 35 3/8" VENT WIDTH TYPICAL ELEVATIONS THESE WINDOWS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. 1/8" HEAT STREN'D. GLASS .090" Interlayer Trosifol PVB By 'Kuraray America, Inc.' 1/8" HEAT STREN'D. GLASS SILICONE II II DOW CORNING 899 a GE SCS 2000 ===!I 1c -- i II II II �II I I II II II II II I I II C^ V II it li rn AT 1/4 POINTS ON LITES 29 WIDER THAN 36" ONLY GLASS TYPE 'A' 1/8" HEAT STREN'D. GLASS .090" Interlayer SentryGlas By 'Kuraray America, Inc.' 1/8" HEAT STREN'D. GLASS SILICONE DOW CORNING 899 GE SCS 2000 29 AT 1/4 POINTS ON LITES WIDER THAN 36" ONLY GLASS TYPE 'B' GLAZING OPTIONS II ^,I II II ===!I 1c -- II II II �II I I II II II II II I I II C^ V II it li II il- —1 9 3 32 3/4" 32 3/4" -DECO—GUARD SERIES -200 D.L. OPG. D.L. OPG. ALUMINUM HORIZONTAL ROLLING WINDOW 36 7/8" DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER VENT WIDTH CHARTS SHOWN ON SHEETS 2. TO QUALIFY FOR SMALL MISSILE IMPACT RATING EXTERIOR PLY OF GLASS TYPE 'C' MUST BE TEMPERED. 1/8" HEAT STREWD. GLASS 5/16" AIR SPACE 1/8" HEAT STREN'D. GLASS .090" Interlayer Trosifol PVB By 'Kuraray America, Inc.' 1/8" HEAT STREWD. GLASS CARDINAL XL DG STEEL ST SILICONE DOW 899 AT 1/4 POINTS 29 ALL SIZES GLASS TYPE 'C' APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF H.R./H.R. OR HORIZONTAL ROLLING WITH OTHER WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS USING MIAMI—DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2014 (STH EDITION)/2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). IBY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON—METALLIC AND NON—COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2014/2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR ,I WATER INFILTRATION RESISTANCE ETC. I: I. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL. ``11116161! frY� SETTING BLOCKS AT z._-•;:.<..,:;: LAM. GLASS AND INSUL. LAM. GLASS"- NOTCH GLAZING BEAD LEG TO CLEAR BLOCKS sy VL) U w n_ I rn Z � rv0• 3 O Z N Q N I O0 ` "��' a O �Hti Ci p ui ri C0 --M o O aco O !A 0 Q Ii1 ZN ^ LL Z N r - o �ZMQ w Q W Q1 I- N � U N J I • ao cam• yLO ••y W •� ice+• N I j w • BE U}td•• o O o��. N 0 ooLjo W Z LL_ j o a �J c� • w oo 2' •w (sheet 1 of 7j A = NO. OF ANCHORS PER HEAD & SILL (} = NO. OF ANCHORS PER JAMB * MAX. LOAD FOR THESE SIZES IS -90.0 PSF WITH (4) ANCHORS AT MTG. STILE ENDS LEFT AND RIGHT VENTS TO BE OF EQUAL GLASS DLO WIDTHS 'XO OR OX' DESIGN LOAD CAPACITY - PSF (X0, OX OR XX SIZES) CAPACITY - WINDOW DIMS. A W/O GLASS 'A' EXT.(+) REINF. TYPE INT.(-) GLASS 'B' EXT.(+) WITH TYPE INT.(-) REINF. GLASS 'C' EXT.(+) TYPE INT.(-) WIDTH HEIGHT 26-1/2" 37" 53-1/8" 74" 26" (3) 4 70.0 80.0 80.0 90.0 70.0 80.0 4 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 26-1/2- 37" 53-1/8" 74" 38-3/8" (4) 4 70.0 80.0 80.0 90.0 70.0 80.0 4 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 8 70.0 1 80.0 80.0 90.0 70.0 80.0 26-1/2" 37" 53-1/8- 74" 50-5/8" (5) 4 70.0 80.0 80.0 90.0 70.0 80.0 4 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 8 70.0 80.0 80.0 90.0 70.0 80.0 26-1/2- 37" 53-1/8" 74" 63" (6) 4 70.0 80.0 80.0 90.0 70.0 80.0 4 68.9 77.5 80.0 90.0 70.0 80.0 6 70.0 70.0 80.0 90.0 70.0 80.0 8 70.0 70.0 80.0 80.4 * 70.0 80.0 24" 36" 48" 60" 72" 23) 4 70.0 80.0 80.0 90.0 70.0 80.0 4 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 8 70.0 80.0 80.0 90.0 70.0 80.0 24" 36" 48" 60" 72" (4) 4 70.0 80.0 80.0 90.0 70.0 80.0 4 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 8 70.0 80.0 80.0 90.0 70.0 80.0 24" 36" 48" 60" 72" 45) 4 70.0 80.0 80.0 90.0 70.0 80.0 4 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 8 70.0 80.0 80.0 90.0 70.0 80.0 24" 36" 48" 60" 72" Ou (6) 4 70.0 80.0 80.0 90.0 70.0 80.0 4 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 70.0 80.0 90.0 70.0 80.0 6 70.0 70.0 80.0 90.0 70.0 80.0 8 F70.0 70.0 80.0 87.6 * 70.0 80.0 A = NO. OF ANCHORS PER HEAD & SILL (} = NO. OF ANCHORS PER JAMB * MAX. LOAD FOR THESE SIZES IS -90.0 PSF WITH (4) ANCHORS AT MTG. STILE ENDS LEFT AND RIGHT VENTS TO BE OF EQUAL GLASS DLO WIDTHS 'XO OR OX' A = NO. OF ANCHORS PER HEAD & SILL () = NO. OF ANCHORS PER JAMB * MAX. LOAD FOR THESE SIZES IS --90.0 PSF WITH (4) ANCHORS AT MTG. STILE ENDS (1/3W) DESIGN LOAD CAPACITY - PSF (XOX SIZES) WINDOW DIMS. A W/O GLASS `A' EXT.(+) REINF. TYPE INT.(-) GLASS `B' EXT.(+) WITH TYPE INT.(-) REINF. GLASS 'C' EXT.(+) TYPE INT.(-) WIDTH HEIGHT 74" 106-1/4" ill" 26„ (3) 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 74" 106-1/4" 111 ° 38-3/8" (4) 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 1 80.0 90.0 70.0 80.0 74" 106-1/4- ill* 50-5/8" (5) 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 74" 106-1/4" 66) 9 70.0 70.0 80.0 90.0 70.0 80.0 12 70.0 70.0 80.0 82.6 * 70.0 80.0 12 70.0 70.0 80.0 80.4 * 70.0 80.0 72" 64" 96" 108" 24" (3) 9 70.0 80.0 80.0 90.0 70.0 80.0 9 70.0 80.0 80.0 ' 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 72" 84" 96" 108" 36" (4) 9 70.0 1 80.0 80.0 90.0 70.0 80.0 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 72" 84" 96" 108" 48" (5) 9 70.0 80.0 80.0 90.0 70.0 80.0 9 70.0 80.0 80.0 I 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 1 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 72" 84" 96" 108" 60" (6) 9 70.0 70.0 80.0 90.0 70.0 80.0 9 70.0 70.0 80.0 90.0 70.0 80.0 12 1 70.0 70.0 80.0 90.0 * 70.0 80.0 12 1 70.0 70.0 80.0 87.6 * 70.0 80.0 A = NO. OF ANCHORS PER HEAD & SILL () = NO. OF ANCHORS PER JAMB * MAX. LOAD FOR THESE SIZES IS --90.0 PSF WITH (4) ANCHORS AT MTG. STILE ENDS (1/3W) (1/3W) (1/3W) PSF (XOX SIZES) WINDOW DIMS. OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH U40 ALL EXTERIOR(+) LOADS SHOWN ON THIS SHEET ARE FOR WINDOWS WITH ADD-ON RISER AT FRAME SILL FOR STD. SILL (NO RISER) LIMIT EXT.(+) LOADS TO 67.0 PSF SEE SHEET 3 FOR DETAIL. A = NO. OF ANCHORS PER HEAD & SILL ( ) = NO. OF ANCHORS PER JAMB (1/4W) DESIGN LOAD CAPACITY - PSF (XOX SIZES) WINDOW DIMS. A W/O REINF. • • WITH REINF. •• GLASS TYPE GLASS TYPE GLASS 'A' B' TYPE C' WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) EXT.(+) INT.(-) 74" 106-1/4" ill" 26" (3) 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 8010 12 70.0 80.0 80.0 90.0 70.0 80.0 74"38-3/8" 106-1/4" 111" (4) 9 70.0 80.0 80.0 90.0 70.0 80.0 12 - - 80.0 90.0 1 70.0 80.0 12 - - 80.0 90.0 70.0 80.0 74" 50-5/8" (5) 9 70.0 80.0 80.0 90.0 70.0 80.0 74" 63" (6) 9 70.0 70.0 80.0 90.0 70.0 80.0 72" 84" 96" 108" 24" (3) 9 70.0 80.0 80.0 90.0 70.0 80.0 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 72" 84" 96" 108" 36" (4) 9 70.0 80.0 80.0 90.0 70.0 80.0 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 - - 80.0 90.Q 70.0 80.0 72" 84" 96" '48.9 (5) 70.0 80.0 80.0 90.0 70.0 80.0 9 70.0 70.0 80.0 90.0 70.0 80.0 12 70.0 70.0 80.0 90.0 70.0 80.0 72" 60" (6) 9 70.0 70.0 80.0 90.0 70.0 80.0 ALL EXTERIOR(+) LOADS SHOWN ON THIS SHEET ARE FOR WINDOWS WITH ADD-ON RISER AT FRAME SILL FOR STD. SILL (NO RISER) LIMIT EXT.(+) LOADS TO 67.0 PSF SEE SHEET 3 FOR DETAIL. A = NO. OF ANCHORS PER HEAD & SILL ( ) = NO. OF ANCHORS PER JAMB (1/4W) (1/2W) (1/4W) i ••. • �i OPERATING VENTS TO BE 1/4 OF THE WINDOW WIDTH V0 W Cqi rn Z 03 0ko os M N Q Q IL "q O:OO,�0 O L Ix c- U. 0 ton V c uI ••I 0'0'-m O 0 alp 00 U) O Q ujnW W N - O ZOE M ZMa w Q W O F • •8 =E J N o U ••. • �i • • J In • • ZU•0 O `w)w-.•v a .. dP w• J •• O W • •� • • • •8 G1 ••. • Q Z U- 00 � 00Lno 3•ao • • • • ZU•0 O `w)w-.•v a .. dP w• J O W - W 00 i 'XOX' NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 `\v11\1E lllddd7'' Op \ J I ?-11oZ•Z3 a r+ t' t TATS OF ,46 a mm N M a 47 l N v o 0 0 6 drawing no. W09-12 sheet 2 of - TYPICAL ANCHORS b 1B SEE ELEV. w WOOD BUCK FOR SPACING EDG DIST. � N METAL d " .e o. EDGC.. DIST:' EDGE DIST. STRUCTURE MIAMI—DADE COUNTY APPROVED m � 0 „ MULLION & MULLION ANCHORS p Z �. ° ,. SEE SEPARATE NOA � I o Z M I z EDGE DIST. m 0 F w m a N -- 0 W N O m l9 � aN �� 0�tnvq ti 19 ci0Wm ud 0'0m 0 1 0 IL G .� 9 TYPICAL ANCHORS TYPICAL ANCHORS TYPICAL ANCHORS 0 N 0 I SEE ELEV. SEE ELEV. SEE ELEV. d1: Z LU I is r. FOR SPACING FOR SPACING FOR SPACING Z rn 0 I II II II it O L .. I III� i "� ZOZOQ —1 I II II h h Q lad Om1 � IW— ii WOOD BUCKS AND METAL STRUCTURE NOT BY ECO WDW. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM _ N AND TRANSFER THEM TO THE BUILDING STRUCTURE. i1 II i J U CD TYPICAL ANCHORS: SEE ELEV. FOR SPACING ii i': i! WEEPHOLES: V) 1f 4" DIA. ULTRACON BY ELCO (Fu-177 KSI, Fy=155 KSI) • o g • •,� W1 = 3/8" X 2-1/4" WEEPHOLES AT EACH END INTO 2BY WOOD BUCKS OR WOOD STRUCTURES " 0% UJ ••�� F {1; ii i1 it .i AND 37" O.C. MAX. 1-1/2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS)••• g U) �•U) w •� X a I: II i1 it .i • h«9tD• • i I U-1 SEALANT: THRU 1 BY BUCKS INTO CONC. OR BLOCKS .. W10 _ O = 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) ••• �' a � W � ALL JOINTS AND FRAME CONNECTIONS SEALED WITH 0 o F i z 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) •• •� O Z iia i Ii JOINT SEALER. t5 • • • I 0 0 LO W I it i DIRECTLY INTO CONCRETE OR BLOCKS • _Z LL_ °c oo i1 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 0 "' • 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) •. O e.L_j •v ca X14 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) c_;- W 55 l i !i ii INTO MIAMI-DADE COUNTY APPROVED MULLIONS ii ii ii i! i! OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS) (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE E� I II IInmm ALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.) W 9 STEEL: 1/8" THK. MIN. (Fy = 36 KSI MIN.) N a s o (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) o 0 0 0 0 it it li li OO cl < TYPICAL EDGE DISTANC N� 2 NOf N� INTO CONCRETE AND MASONRY = 2-1/2" MIN. °� < 5 a U UJ INTO WOOD STRUCTURE = 1 " MIN. w a u N INTO METAL STRUCTURE = 3/4" MIN. O s Q t5 y B I 13 M 3 N >o =g X WOOD AT HEAD, SILL OR JAMBS SG = 0.55 MIN. 0 o w o a c� CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN. 0 0 0 I 3 V' `` J N o v (n C-90 HOLLOW/FILLED BLOCK AT JAMBS fm = 2000 PSI MIN. BOLL,w w 26 pp A�4f iCA a a .rYN 70592 = o cn Tn ,y L •D v : v v e j I TYPICAL ANCHORS TYPICAL ANCHORS A-`•et;F''c.�tt BY t�`.7:3 e SEE ELEV. SEE ELEV. :x.�•i ; r;_ ; ; : ® NATE ®F •��+ drawing n0. FORSPACING WOOD BUCK FOR SPACING • w1a �� • ®diso�.•��®.`� W09— 1 2 EDGE DIST, i.,;2s;3i ., N�� EDGE DIST. _I c.n y.. ct^Writ�3 �// ® �\ //ddlllle��� sheet 3 of 7 ••9.•• • • 0090•• •9•••9 0 9.0.0 0•.•09 1/4* MAX. U 0 SHIMS cwv 1/4' MAX. SHIM O O O 1 5 WOOD BUCKS Z � � � 21 8 7 0 M z 17 'TYPICAL ANCHORS f" W toTYPICAL ANCHORS ° SEE ELEV. a to d SEE ELEV. °. FOR SPACING a e a 2 FOR SPACING - _ -_ _ _ _ = 25 O O9 O ` U N ri N 17 20 1 1 f4" 0 j W Al LAK 0 ----- SCREEN OPT.------- _ — -- �ii a m � W 20 — __— = p aaa as 27 �" w O'�rua d ° o vi V1 0 m s w 4 STEEL REINFORCING 11 17 12 ° z N LL o METAL AS REQD. a t O STRUCTURE SEE SHEET 2 FOR CAPACITY v J Z Q WINDOW WIDTH a O ~ XO LAYOUT N O U m 1/4" MAX. 3 In -1 ull VENT WIDTH VENT WIDTH SHIMS ro 1 /4" MAX. C, Rn SHIM D.L. OPG. D.L OPG. 1 BY a C WOOD BUCKS & W 20 TYPICAL ANCHORS • i) LA L• } X•••• 17T v ' SEE ELEV. • . N m U v . FOR SPACING £; �Q • • • mo ct 1 /2" _ _ - _ - - - 25 = - - _ _ - _ . • �. 3 L•. --_ _ ---_ ---- •• Q 3 !� 0 O `1 • • . v, � ° �r Z ...�. w .. ••• • m 17 20 1 1f4" • Z a ----SCREEN OPT ----- ----. — : — — — — _ —SCREEN OP -- ° .. o • • • .`I? a 20 27 --— vo w i w W��yW- o • g t7 w ••• • 4 11 12 D.L. OPG. STEEL REINFORCING a • • • • \AS REQD. EXTERIOR SEE SHEET 2 FOR CAPACITY v P WINDOW WIDTHU. m a TYPICAL ANCHORS XOX LAYOUT 1.0 W Z N N SEE ELEV. - o 0 0 FOR SPACING ¢ ao In yz a a a a MIAMI—DADE COUNTY APPROVED MULLION TYPICAL ANCHORS SEE SEPARATE NOA SEE ELEV. FOR SPACING W�,2 cy N Q No 70592 ----SCREEN OPT.°u z_xk,�racir+r=,. a5_j_a_2i2ar ' ATE OF °�� drawing no. ;,;� ®R{DP.°°°��`\ wog-1 2 ;:_ _ Sc a"g 2.ho �� WINDOW WIDTH WINDOW WIDTH P�`_;3,:ai 1:�.: ';,rh _•".. ,_ ��/d ®NAL dddPlllf4{�� sheet 4 of 7 EDGE DIST TYPICAL ANCHORS SEE ELEV. FOR SPACING o . TYPICAL ANCHORS SEE ELEV. FOR SPACING METAL STRUCTURE EDGE DIST. MIAMICOUNTY APPROVED MULLION ION & & MULLION ANCHORS VI 1 SEE SEPARATE NOA II EDGE TYPICAL ANCHORSTYPICAL ANCHORS SEE ELEV. SEE ELEV. FOR SPACING FOR SPACING 1/4" MAX. SHIMS TYPICAL ANCHORS SEE ELEV. FOR SPACING INSTALLATION DETAILS WITH FLUSH FRAME ADAPTER O ALT. O W N I rn -� c d 0 ti Qw IL Ia m op�,00 o doW 0 va> � Ir o 0n.000A 0 r Q W 7 IL N LL, Q LLI OM1 FF - N U o J m 3 00 z (n � W r�i o V) W•• • •� i- a_'•••• • • (,Q to •• O 0n.n 00 00 •.. Z 3�.. N • Q W(p:2- • �5 • _ L, u- O H N N OQ O 0 U Q N Q Q 2 IL ?. n `eaaaaaalrerrf� �® AH, aGEAaS'F • ® �i cor.ptviynj- yin{ tL.v HCii i1< e .r laixm ej r � a �•. S TE OF p •jj�� n�JJ�� '=Sw 1-i ��.+fiL�6�1Pa \�\\ rrrrralaaaa\ cV N m O O � o N ' IN Q o \ r 2- 00 U t V W V U drawing no. W09-12 sheet 5 & 7 1 3.. I Oi FRAME HEAD ilKiZ31 a .715 1 1.434 .813 062 IB 1.140! 1.140 _T --1.s10 .813 1.058 3.876 .078 2.501 .500 f� 2.750 O FRAME SILL 1.314- F.250 .340 .312 .062 �3 SILL TRACK 2.750 2.812 LO MOV. FRAME JAMB O VENT TOP/BOTTOM RAIL STEEL REINFORCING -2.095---1.519 130 1.250 T__- .719A4 803 .045 8�3 2.246 1.140 1.047 I 1.047 .062 I21 s 1 o GLAZING BEADS o� l-- 1.344 --P1 OS JAMB STILE 2.063 1.250 1.1140 062 1.340 I-- 1.344 -di 7O MEETING RAIL 2.155--1 _t 1.422 171.202 1 f --1.375--i O FIXED MTG. RAIL 750 F.06652- 2.812 Fr 1 2.750 -2.688 .06 .os2 .500 69 �2.611� 28 FLUSH FRAME ADAPTER ITEM PART $ L.969 1.688 eJ5 FIXED FRAME JAMB -2.688 .06 .os2 .500 69 �2.611� 28 FLUSH FRAME ADAPTER ITEM PART $ QUANTITY DESCRIPTION MATERIAL MANF./SUPPLIER/REMARKS 1 FY201 1 FRAME HEAD 6063-T6 - 2 FY202 1 FRAME SILL 6063-T6 - 3 FY203 1 SILL TRACK INSERT 6063-T6 - 4 FY205 AS READ, MOV. FRAME JAMB 6063-T6 - 5 FY101 AS READ. FIXED FRAME JAMB 6063-T6 - 6 FY104 1/ VENT FIXED MTG. RAIL 6063-T6 - 7 FY105 1/ VENT VENT INTERLOCK 6063-T6 - 8 FY206 1/ VENT JAMB STILE 6063-T6 - 9 FY107 2/ VENT TOP AND BOTTOM RAIL 6063-T6 - 10 FY10B AS REQD. GLAZING BEAD (LAM. GLASS) 6063-T6 - 10A FY110 AS REQD. GLAZING BEAD (INSUL. LAM. GLASS) 6063-T6 - 11 - AS REQD. REINFORCING BAR STEEL - 12 - AS REQD. REINFORCING BAR STEEL - 13 FY204 AS RTEQD. ADD-ON SILL RISER 6063-T6 USE AS REQD. 14 FY208 4/ VENT ROLLER HOUSING & GUIDE CELCON 15 FY209 2/ VENT ROLLER BRASS - 16 FY210 2/ VENT ROLLER PIN ST. STEEL - 17 #8 X 1" AS REQD. FRAME/VENT ASSEMBLY SCREWS CRS P.H. SMS 18 #8 X 3" 2/ VENT FIX. RAIL SILL SCREWS (SILL END) CRS P.H. SMS 19 W23181 AS REQD. FIN SEAL W'STRIPPING - ULTRAFAB 20 Q300T190 AS READ. BULB SEAL Q-LON SCHLEGEL 21 E207 AS REQD. BULB SEAL SANTOPRENE ULTRAFAB, DUROMETER 65±5 22 E203 AS REQD. GLAZING BEAD BULB SANTOPRENE ULTRAFAB, DUROMETER 65±5 23 FLB-50 AS REQD. GLASS SPACER SILICONE FRANK LOWE 24 SL203P 2/ VENT SWEEP LATCH - SULLIVAN & ASSOC. • 25 #8 X 1/8" 2/ LATCH LATCH INST. SCREW ST. STEEL OH SMS • 26 WA2L 2/ WDW. WEEP VALVE - PREFERRED ENG. PRODUCA* 27 - 1/ VENT 5/16" BOX SCREEN - OPTIONAL 28 FY120 - FLUSH FRAME ADAPTER 6063-T6 OPTIONAL '• 29 - 2/ LITE I SETTING BLOCK EPDM DUROMETER 80±5 SHORE ,A• V0 w N I rn Z �h Oz n W � I c0 O Ujj (S O a " 0 �Nh O,oa>Ia"t 0 oa $ 0 Nu�1� O N Q WSW to LLzw -o aW0) uj C14 = o U o J ul m C> r�� Ld C) W i •s } pj••• U) . cft J � LO •g 3 0 F2i 0 0 00 .� Z ••{�•� 3 s: Z >i •�n �.. • • • U oLr) � W.00 m.W . . C, W U m U m K 0 4 n n O z z 0 0 0 W W a 5 a (L NI� olnl ol� ``�yy11111f/f�� ` EN ®. 92 - T Acca;,) ince `�?r_k1!>2U�Z3 % OF is%�.Si<i(3FJ4. s�1�I� ��j� drawing no. � • • •• ���.� W09-1 2 :xssrt-1 A �®pa1II�y% sheet 6 of 7 17 VENT TOP/BOTTOM CORNERS jZ FIXED MTG. RAIL CORNER 17 T FRAME BOTTOM CORNER 17 �` V0 U w N E rn 0 Oi CL h W � E a a Op` �o U a�N �o 4 �ti v o°>M � .Em S p IL 0 C �W�°- �3 J nm¢ Q w oMi �' N � O U LO o J ol 31-c co c� M: Vc) n O G M ce W IV F— F— Ckf ..• N Q •..]�Gcl, co Z• J.00 ... r O 0. •n .... U LWoo OW WLR x__ O K N CD w w 0 ao C a R o o a z z D V!� oo0 r dl , EN ® N G7 N \ F¢ 7 92 >�i;_:icz:aha��_o�ltt��ii �® '• i EOF drawing no. Y„ _ •� z�, o '�� �.�pprt��4+,�.•��,�; W09-12 AL '# /a1111110 sheet 7 of 7