Loading...
RC-9-16-2500_1460 NE 103 St_PlansMiami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 fiE Phone: (305)795-2204 �oaty Project Address 1460 NE 103 Street Miami Shores, FL Owner Information MONICA SAVITS Parcel Number Applicant 1132050310060 Block: Lot: Address 1360 N. E. 103 ST. Contractor(s) Phone Cell Phone POOLS BY G.E. CORP (786)732-0614 (786)355-3382 Approved: In Review Comments: Date Approved:: In Review Date Denied: Type of Work: Swimming Pool Additional Info: Classification: Residential Fees Due Amount CCF $10.80 CO/CC Fee $50.00 DBPR Fee $8.10 DCA Fee $5.40 Education Surcharge $3.60 Permit Fee $540.00 Plan Review Fee (Engineer) $80.00 Scanning Fee $9.00 Technology Fee $14.40 Total: $721.30 Occupancy: Private Bond Return Scanning: 3 CHRISTOPHER SAVITS Cell I Valuation: $ 18,000.00 Total Scl Feet: 300 r Pay Date Pay Type Amt Paid All Due Invoice # BPP-5-17-63960 05/09/2017 Check #: 1499 $ 50.00 $ 671.30 01/09/2018 Check* 105 $ 671.30 $ 0.00 Hvanaoie Inspection Type: Fence Final Pool Deck Wall Steel Review Electrical Review Electrical Review Planning Review Building Review Structural Review Plumbing In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, P UMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: ify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoni g he re, I authorize the above -named contractor to do the work stated. January 09, 2018 Autho r fat I . Owner / Applicant / Contractor / Agent Date Buildirfg Department Copy January 09, 2018 1 OUTDOOR SWIMMING BARRIER COMPLYING WITH 5TH EDITION (2014) R4501.17.1.1 THROUGH R4501.17.1.15 THE TOP OF THE BARRIER SHALL BE AT LEAST 48 INCHES (1219 MM) ABOVE GRADE MEASURED ON THE SIDE OF THE BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL. THE MAXIMUM VERTICAL CLEARANCE BETWEEN GRADE AND THE BOTTOM OF THE BARRIER SHALL BE 2 INCHES (51 MM) MEASURED ON THE SIDE OF THE BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL WHERE THE TOP OF THE POOL STRUCTURE IS ABOVE GRADE THE BARRIER MAY BE AT GROUND LEVEL OR MOUNTED ON TOP OF THE POOL STRUCTURE. WHERE THE BARRIER IS MOUNTED ON TOP OF THE POOL STRUCTURE, THE MAXIMUM VERTICAL CLEARANCE BETWEEN THE TOP OF THE POOL STRUCTURE AND THE BOTTOM OF THE BARRIER SHALL BE 4 INCHES (102 MM). THE BARRIER MAY NOT HAVE ANY GAPS, OPENINGS, INDENTATIONS, PROTRUSIONS, OR STRUCTURAL COMPONENTS THAT COULD ALLOW A YOUNG CHILD TO CRAWL UNDER, SQUEEZE THROUGH, OR CUMB OVER THE BARRIER AS HEREIN DESCRIBED BELOW. ONE END OF A REMOVABLE CHILD BARRIER SHALL NOT BE REMOVABLE WITHOUT THE AID OF TOOLS. OPENINGS IN ANY BARRIER SHALL NOT ALLOW PASSAGE OF A 4-INCH-DIAMETER (102 MM) SPHERE. SOLID BARRIERS WHICH DO NOT HAVE OPENINGS SHALL NOT CONTAIN INDENTATIONS OR PROTRUSIONS EXCEPT FOR NORMAL CONSTRUCTION TOLERANCES AND TOOLED MASONRY JOINTS. WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF THE HORIZONTAL MEMBERS IS LESS THAN 45 INCHES (1143 MM), THE HORIZONTAL MEMBERS SHALL BE LOCATED ON THE SWIMMING POOL SIDE OF THE FENCE. SPACING BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 1-3/4 INCHES (44 MM) IN WIDTH. WHERE THERE ARE DECORATIVE CUTOUTS WITHIN VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS SHALL NOT EXCEED 1-3/4 INCHES (44 MM) IN WIDTH. WHERE THE BARRIER IS COMPOSED OF HORIZONTAL AND VERTICAL MEMBERS AND THE DISTANCE BETWEEN THE TOPS OF THE HORIZONTAL MEMBERS IS 45 INCHES (1143 MM) OR MORE, SPACING BETWEEN VERTICAL MEMBERS SHAD_ NOT EXCEED 4 INCHES (102 MM). WHERE THERE ARE DECORATIVE CUTOUTS WITHIN VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS SHALL NOT EXCEED 1-3/4 INCHES (44 MM) IN WIDTH. MAXIMUM MESH SIZE FOR CHAIN LINK FENCES SHALL BE A 2-1/4 INCH SQUARE (57 MM) UNLESS THE FENCE IS PROVIDED WITH SLATS FASTENED AT THE TOP OR BOTTOM WHICH REDUCE THE OPENINGS TO NO MORE THAN 1-3/4 INCHES (44 MM). WHERE THE BARRIER IS COMPOSED OF DIAGONAL MEMBERS, THE MAXIMUM OPENING FORMED BY THE DIAGONAL MEMBERS SHALL BE NO MORE THAN 1-3/4 INCHES (44 MM). ACCESS GATES, WHEN PROVIDED, SHALL BE SELF -CLOSING AND SHALL COMPLY WITH THE REQUIREMENTS OF SECTIONS R4501.17.1.1 THROUGH R4501.17.1.7 AND SHALL BE EQUIPPED WITH A SELF -LATCHING LOCKING DEVICE LOCATED ON THE POOL SIDE OF THE GATE WHERE THE DEVICE RELEASE IS LOCATED NO LESS THAN 54 INCHES (1372 MM) FROM THE BOTTOM OF THE GATE, THE DEVICE RELEASE MECHANISM MAY BE LOCATED ON EITHER SIDE OF THE GATE AND SO PLACED THAT IT CANNOT BE REACHED BY A YOUNG CHILD OVER THE TOP OR THROUGH ANY OPENING OR GAP FROM THE OUTSIDE GATES THAT PROVIDE ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM THE POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18 INCHES (457 MM) OF THE RELEASE MECHANISM. ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOL SHALL BE EQUIPPED WITH AN EXIT ALARM COMPLYING WITH UL 2017 THAT HAS A MINIMUM SOUND PRESSURE RATING OF 85 DB A AT 10 FEET (3048 MM). THE EXIT ALARM SHALL PRODUCE A CONTINUOUS AUDIBLE WARNING WHEN THE DOOR AND ITS SCREEN ARE OPENED. THE ALARM SHALL SOUND IMMEDIATELY AFTER THE DOOR IS OPENED AND BE CAPABLE OF BEING HEARD THROUGHOUT THE HOUSE DURING NORMAL HOUSEHOLD ACTIVITIES. THE ALARM SHALL BE EQUIPPED WITH A MANUAL MEANS TO TEMPORARILY DEACTIVATE THE ALARM FOR A SINGLE OPENING. SUCH DEACTIVATION SHALL LAST NO MORE THAN 15 SECONDS. THE DEACTIVATION SWITCH SHALL BE LOCATED AT LEAST 54 INCHES (1372 MM) ABOVE THE THRESHOLD OF THE DOOR. SEPARATE ALARMS ARE NOT REQUIRED FOR EACH DOOR OR WINDOW IF SENSORS WIRED TO A CENTRAL ALARM SOUND WHEN CONTACT IS BROKEN AT ANY OPENING. EXCEPTIONS: A. SCREENED OR PROTECTED WINDOWS HAVING A BOTTOM SILL HEIGHT OF 48 INCHES (1219 MM) OR MORE MEASURED FROM THE INTERIOR FINISHED FLOOR AT THE POOL ACCESS LEVEL. B. WINDOWS FACING THE POOL ON FLOOR ABOVE THE FIRST STORY. C. SCREENED OR PROTECTED PASS -THROUGH KITCHEN WINDOWS 42 INCHES (1067 MM) OR HIGHER WITH A COUNTER BENEATH. ALL DOORS PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOL MUST BE EQUIPPED WITH A SELF -CLOSING, SELF -LATCHING DEVICE WITH POSITIVE MECHANICAL LATCHING/LOCKING INSTALLED A MINIMUM OF 54 INCHES (1372 MM) ABOVE THE THRESHOLD, WHICH IS APPROVED BY THE AUTHORITY HAVING JURISDICTION. WHERE AN ABOVEGROUND POOL STRUCTURE IS USED AS A BARRIER OR WHERE THE BARRIER IS MOUNTED ON TOP OF THE POOL STRUCTURE, AND THE MEANS OF ACCESS IS A LADDER OR STEPS, THE LADDER OR STEPS EITHER SHALL BE CAPABLE OF BEING SECURED, LOCKED OR REMOVED TO PREVENT ACCESS, OR THE LADDER OR STEPS SHALL BE SURROUNDED BY A BARRIER WHICH MEETS THE REQUIREMENTS OF SECTIONS R4501.17.1.1 THROUGH R4501.17.1.9 AND SECTIONS R4501.17.1.12 THROUGH R4501.17.1.14. WHEN THE LADDER OR STEPS ARE SECURED, LOCKED OR REMOVED, ANY OPENING CREATED SHALL NOT ALLOW THE PASSAGE OF A 4-INCH-DIAMETER (102 MM) SPHERE STANDARD SCREEN ENCLOSURES WHICH MEET THE REQUIREMENTS OF SECTION R4501.17 MAY BE UTILIZED AS PART OF OR ALL OF THE 'BARRIER" AND SHALL BE CONSIDERED A "NONDWELUNG" WALL REMOVABLE CHILD BARRIERS SHALL HAVE ONE END OF THE BARRIER NONREMOVABLE WITHOUT THE AID OF TOOLS. THE BARRIER MUST BE PLACED AROUND THE PERIMETER OF THE POOL AND MUST BE SEPARATE FROM ANY FENCE, WALL, OR OTHER ENCLOSURE SURROUNDING THE YARD UNLESS THE FENCE, WALL, OR OTHER ENCLOSURE OR PORTION THEREOF IS SITUATED ON THE PERIMETER OF THE POOL. IS BEING USED AS PART OF THE BARRIER, AND MEETS THE BARRIER REQUIREMENTS OF THIS SECTION. REMOVABLE CHILD BARRIERS MUST BE PLACED SUFFICIENTLY AWAY FROM THE WATER'S EDGE TO PREVENT A YOUNG CHILD OR MEDICALLY FRAIL ELDERLY PERSON WHO MAY MANAGE TO PENETRATE THE BARRIER FROM IMMEDIATELY FALLING INTO THE WATER. SUFFICIENTLY AWAY FROM THE WATER'S EDGE SHALL MEAN NO LESS THAN 20 INCHES (508 MM) FROM THE BARRIER TO THE WATER'S EDGE DWELLING OR NONDWELUNG WALLS INCLUDING SCREEN ENCLOSURES, WHEN USED AS PART OR ALL OF THE "BARRIER' AND MEETING THE OTHER BARRIER REQUIREMENTS, MAY BE AS CLOSE TO THE WATER'S EDGE AS PERMITTED BY THIS CODE. A WALL OF A DWELLING MAY SERVE AS PART OF THE BARRIER IF IT DOES NOT CONTAIN ANY DOOR OR WINDOW THAT OPENS TO PROVIDE DIRECT ACCESS FROM THE HOME TO THE SWIMMING POOL PROHIBITED LOCATIONS. A BARRIER MAY NOT BE LOCATED IN A WAY THAT ALLOWS ANY PERMANENT STRUCTURE, EQUIPMENT, OR WINDOW THAT OPENS TO PROVIDE ACCESS FROM THE HOME TO THE SWIMMING POOL ADJACENT WATERWAYS. PERMANENT NATURAL OR PERMANENT MAN-MADE FEATURES SUCH AS BULKHEADS, CANALS, LAKES, NAVIGABLE WATERWAYS, ETC., ADJACENT TO A PUBLIC OR PRIVATE SWIMMING POOL OR SPA MAY BE PERMITTED AS A BARRIER WHEN APPROVED BY THE AUTHORITY HAVING JURISDICTION. WHEN EVALUATING SUCH BARRIER FEATURES, THE AUTHORITY MAY PERFORM ON -SITE INSPECTIONS AND REVIEW EVIDENCE SUCH AS SURVEYS, AERIAL PHOTOGRAPHS, WATER MANAGEMENT AGENCY STANDARDS AND SPECIFICATIONS, AND ANY OTHER SIMILAR DOCUMENTATION TO VERIFY, AT A MINIMUM. THE FOLLOWING: 1. THE BARRIER FEATURE IS NOT SUBJECT TO NATURAL CHANGES, DEVIATIONS, OR ALTERATIONS AND IS CAPABLE OF PROVIDING AN EQUIVALENT LEVEL OF PROTECTION AS THAT PROVIDED BY THE CODE. 2. THE BARRIER FEATURE CLEARLY IMPEDES, PROHIBITS OR RESTRICTS ACCESS TO THE SWIMMING POOL OR SPA. EXISTING U.G. ELECTRICAL SERVICE EXISTING 200AMP. ELECTRICAL METER EXISTING 200AMP. ELECTRICAL PANEL EXISTING 4 FT HIGH CHAIN LINK FENCE (TO BE USED AS PART OF POOL BARRIER) EXISTING BRICK ON SAND POOL DECK TO REMAIN EXISTING POOL TO BE REMODELED UNDER THIS PERMIT- SEE SCOPE OF WORK NOTE IN THIS PAGE- SCOPE OF WORK: REMODELING EXISTING POOL INCLUDES: 1. BUILD NEW SPA ATTACHED TO EXISTING POOL. 2. BUILD NEW INFINITY BASIN ATTACHED TO EXISTING POOL. 3. CHANGE DEPTH OF EXISTING POOL FROM 7'-0' TO 5'-0" AT DEEP END 4. INSTALL NEW POOL PIPING AND FILTRATION SYSTEM 5. INSTALL NEW POOL LIGHTS 6. PROVIDE NEW POOL BONDING #Xev4 r, �1 I i 1 o to I' TILE T TWO STORY A/C AREA f 1— " WOOD DOCK PROVIDE ALARMS ALL WINDOWS AND DOORS WITH ACCESS TO THE POOL ON ANY WALLS OF THE HOUSE USED AS PART OF THE BARRIER COMPLYING WITH 5TH EDITION (2014) FBC R45 01.17.1.9 RE -PLAT OF TR C MIAMI SHORES BAY PARK ESTS PB 64-97 LOT 15 BLK 5 LOT SIZE IRREGULAR OR 13702-870 0688 1 COC 25631-2753 05 2007 1 Y\C ` R=25.00' \,Q A=25.0-r / /EXISTING WATER LINE ASPHALT DRIVEWAY EXISTING DRAIN FIELD / EXISTING SEPTIC TANK % o TER ONE STORY C.B.S. RESIDENCE # 1460 C. BOAT uFT R=200.00' A=85.15' FRw (.0 ! 00 O �1 BRICK STORAGE ! x � I x i I I xI � CONC. \ SEA WALL x ' 36.82' SITE PLAN SCALE "- ' POOL EQUIPMENT PDA CONTROL CENTER POOL EQUIPMENT EXISTING 4 FT HIGH CHAIN LINK FENCE (TO BE USED AS PART OF POOL BARRIER) 7X7 FT SPA NEW 18 FT BENCH NEW 36'x2' FT INFINITY BASIN DRAWING BY G.I.A SWIMMING POOL DESIGN,INC 786-554-7804 ray O N 00 m O� 0 W � H -. to W N CO— LL —_ EU , ct �_ ;s Oz co 0 co 0 � � z a� M w � zz MAW) W U �Qv (= Qi O M Qo 00 Q' O � O kf) ono oar (V U04 w CA a' o N W a WW� a�PLO O aU O SHEET: I of 4 EXISTING RESIDENCE EXISTING 19'-4" EXISTING IMPERVIOUS, SUP RESISTANT CONCRETE PAVER DECK SLOPED 1/8"X FT SLOPE AWAY FROM POOL NOTE: BOND WIRE TO BE SECURED TO EXIST. STEEL WITH APPROVED CLAMP. PROVIDING MIN. 3" OF CONCRETE COVER AROUND CLAMP NOTE: CONTRACTOR SHALL VERIFY ALL SETBACKS FROM PROPERTY LINES AND STRUCTURES PRIOR TO EXCAVATION. SHOULD ANY SETBACKS BE LESS THAN THE MINIMUN REQUIREMENTS, EITHER BY OWNER OR BUILDING OFFICIAL, THE ENGINEER SHALL BE NOTIFIED. EXISTING RESIDENCE EXISTING 1'-5" J BRICK d I EXISTING 1'-6" PAVERS N z z F � W x w # 8 TO POOL PUMP i i I I I I I 1 VACUUMINLET_ Y---r--r---,--I---r--,---�- ', -- INLET INLET INLET INLET INLET INLE [ ILT _--_-__;___- __--_ -r--, W/ # 3t 0 9'r----;---r-- ---1-- I i E7iCHl W�Y I � � I I I I I I I I I I I I I EXISTING POOL STEPS I , I i NEW! 40W 12V LED POOL LIGHT 1' 1' 11-11EXISTING POOL NEW MAIN DRAIN " RISE POOL FLOOR FROM 00 3 —0 DEEP — 7'-0" TO 6'-0" DEEP PROVIDE CONTRASTING TILE NEW SWIMOUT ION STEPS & BENCH EDGE ?00; M, X' BELOW TE r--+-- I i I I I I I I I I I I I -L--� CEO SB1-------'-- —'- Wx-3'0'9"' j '--T---?--' I --T ___I r Y --I I I I I I I I I 1 I I I I I I T--- I �_ II_ I= I I I I I I I I � I 4 I04 2'-0" DIIEP " NEW BASIN =I 36' DETAIL 1 jff (4)15W 12V LED M NICHELESS LIGHT 1NG BRICK PAVERS is POOL PLAN SCALE: 1 /4"= 1'-0" fAR, RPRI POOL DRAWING BY G.I.A SWIMMING POOL DESIGN,INC 786-554-7804 O w REFER TO ISOMETRIC FOR PIPE SIZE C L7 � Ln CIS � W a NOTE: THE PIPING SHOWN IS A GRAPHIC 0 H REPRESENTATION OF PIPE ROUTE,ACTUAL ROUTING OF PIPING AROUND POOL AND TO U W POOL EQUIPMENT MAY DIFFER FROM THIS PLAN M a r� � V W W A Q z O DECK: EXISTING BRICK ON SAND 6'-7" �i LLez N W � SPA FLUSH Z Fz �' p TO POOL ®`L `;� Gj�a s PFLo � JET - JET bc -410" p A O f1 z z 00M� � M Ln JET t° JET JET FIRST STEP W n 0 w 'n - MUST COVER in z _ _ 240 SQ IN. MIN. Z oM 25W 12V LED o SPA UGHT AIL 1 NOTE: PROVIDE CONTINUOS SINGLE # 8 COOPER BONDED IN FOUR POINT(360") AROUND POOL & SPA BL IL INN RE VIEVV AP OVE D 1 I_. USE # 3 ® 9" O.0 EACH WAY DRILL 4" INTO EXISTING CONCRETE WALL AND SET BAR IN EPDXY GROUT BY "HILTY" HIT HY 150 MAX MIN. SPLICE 1 B" —WARNIG: TO EMPTY POOL AFTER CONSTRUCTION FOR REPAIRS OR ANY OTHER REASON, THE HYDROSTATIC UPLIFT PRESSURES BENEATH THE .POOL MUST BE ELIMINATED TO PREVENT THE POOL FROM FLOATING UPWARD. THE OWNER MUST CONSULT AND POOL REPAIR CONTRACTOR EXPERIENCED IN ELIMINATING UPLIFT PRESSURES. ao 00 O Ocn C14 o x U w 4 a' cn o N W a E-+ a W� M En W w W C OO a N v SHEET: 2 OF 4 STRUCTURAL NOTES: ALL WORK SHALL COMPLY WITH THE THE F.B.C. 5TH EDITION (2014). THE AMERICAN CONCRETE INSTITUTE ACI-318-14, ASCE-7-14 AND ALL OTHERS APPLICABLE CODES AND REGULATIONS. 1. ALL POOL CONCRETE SHALL DEVELOP A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI. 2. ALL REINFORCING STEEL SHALL HAVE A MINIMUM YIELD STRENGTH OF 60.000 PSI. 3. ALL DECK CONCRETE (WHEN INSTALLED UNDER THESE PLANS) SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 2500 PSI. 4. THE DESIGN OF THIS PROJECT HAS INCORPORATED A RATIONAL DESIGN APPROACH BASED ON ACCEPTED ENGINEERING PRINCIPALS. 5. ALL REINFORCING STEEL SPLICES SHALL BE 18" IN LENGTH UNLESS OTHERWISE INDICATED ON THESE PLANS. 6. ALL REINFORCING STEEL BENDS SHALL BE BY HAND WITHOUT THE APPLICATION OF HEAT TO THE STEEL SOIL STATEMENT A VISUAL INSPECTION AT JOB SITE SHOWED A SOIL COMPOSED OF SAND AND ROCK. A BEARING CAPACITY OF 2000 P.S.F. HAS BEEN ASSUMED. FURTHER MORE, UPON BREAKING OF GROUND, A LETTER SHALL BE SUBMITED TO THE BUILDING OFFICIAL VERIFYING AND ATTESTING THAT THE SITE CONDITIONS ARE SIMILAR TO THOSE UPON THE DESIGN BASED. HYDROSTATIC UPLIFT ELEV. TOP OF SPA WALL 8.60' DEPTH OF SPA 3.00' ELEV. TOP OF MAINDRAIN 5.60' FLOOD CRITERIA 9.00' ELEV. TOP OF MAINDRAIN 5.60' SPA IN FLOOD CRITERIA 3.4.0' LESS 2.0 HYDROST VALVE 1.40' SLAB THICKNESS REQUIRED 6 NOTE: IF THE SPA IN FLOOD CRITERIA IS LESS THAN 6.7 FEET THEN THE FLOOR SLAB SHALL TAPER FROM 6' AT THE SHALLOW END TO THAT INDICATED ABOVE AS SLAB THICKNESS REQUIRED. EPDXY NOTES HILT! HIT HY-150-MAX INJECTION ADHESIVE ANCHOR PROVIDE CONTRASTING TILE NOTE: PROVIDE 18" MIN. SPLICE ON STEPS & BENCH EDGE AND 3" MIN. CONCRETE COVER PORTION OF EXISTING POOL 14' POOL COPIN WALL TO BE REMOVED POOL COPING " 10" 10" " COOL DECK A R N =W LK N PROVIDE #3 ® 9" N VAj HOR. & VERT = 18„ ON \ PROVIDE #3 0 9" HOR. & VERT LL LL it ANTI VORTEX d MAINDRAIN �I PROVIDE #3 ® 9" I HOR. & VERT FOAM 6 CONCRETE SLAB W/ #3 ®9" EACH WAY w /\ v RELIEF VALVE NO REQUIRED ANTI VORTEX _ /\ " MAINDRAIN `� �� SE # 3 0 9" O.0 EACH WAY \� DRILL 4" INTO EXISTING CONCRETE \WALL , GROUT B� EPDXY SET BAR IN HILTY" HIT HY 150 MAX MIN. SPLICE 18" /\/ USE # 3 0 9" O.0 EACH WAY EXISTING GRAVEL �\�/\// EXISTING DRILL 6" INTO EXISTING POOL FLOOR \\/ _\//\\/j/\/�\\\'�\ �\ POOL WALL CONCRETE FLOOR AND SET BAR PORTION OF EXISTING POOL TIC TATIC RELIEF VALVE IN EPDXY GROUT BY "HILTY" HIT SLAB TO BE CUT IN ORDER '�E�WASHEDIC BED ROCK USE # 3 ® 9" O.0 EACH HY 150 MAX MIN. SPLICE 18" TO INSTALL NEW 2" WAY DRILL 4" INTO EXISTING HYDROSTATIC RELIEF VALVE CONCRETE FLOOR AND SET BAR IN EPDXY GROUT BY "HILTY" HIT HY 150 MAX MIN. SPLICE 18" 1. DRILL HOLES WITH ANSI B212.15 MATCHED TOLERANCE CARBIDE TIPPED DRILL BITS WITH DRILL IN ROTO—HAMMER MODE. DIAMOND CORING HOLES IS NOT PERMITTED. 2. DRILLED HOLE SPECIFICATIONS (DIAMETER & DEPTH) SHALL COMPLY WITH HIL11 SPECIFICATIONS OR ICC ESR 3. ALLOWABLE LOADS MAY BE INCREASED BY UP TO 33-1 3% FOR SHORT—TERM WIND OR SEISMIC LOAD RESISTANCE IAW ICC ESR UNLE S NOT PERMITTED BY THE APPLICABLE BUILDING CODE. 4. WHEN CONDUCTED, PROOF TEST ANCHORS IN THE FIELD TO 150-200% OF HILTI PUBLISHED ALLOWABLE TENSION LOAD UNLESS NOTED OTHERWISE IN A PROOF TEST LOAD TABLE. TORQUE TESTING IS NOT PERMITTED. 5. ANCHORS MAY BE INSTALLED IN DAMP HOLES IAW ICC ESR. INSTALLATION IN HOLES WITH STANDING WATER IS NOT PERMITTED. 6. ANCHORS SHALL BE TIGHTENED WITH A CALIBRATED TORQUE WRENCH. USE OF AN IMPACT WRENCH IS NOT PERMITTED. 7. CONTACT HILT] TECHNICAL SUPPORT AT 1-800-879-8000 FOR ADDITIONAL ASSISTANCE WITH HIT HY-150 MAX ANCHOR INSTALLATIONS. 8. INSTALLATION INSTRUCTIONS: A. FOR HIT HY-150 ADHESIVE WITH ALL —THREAD ROD OR REBAR DOWEL- 1. DRILL ANCHOR HOLE WITH A CARBIDE BIT (SEE NOTE 1 ABOVE), TO SPECIFIED EMBEDMENT DEPTH. 2. CLEAN HOLE IN ACCORDANCE WITH HILTI SPECIFICATIONS OR ICC ESR. 3. PUT ADHESIVE REFILL PACK INTO DISPENSER HOLDER. REMOVE CAP COVERING THREADED PROJECTION. 4. SCREW ON STATIC MIXER NOZZLE. 5. PUT HOLDER/CARTRIDGE INTO APPROPRIATE DISPENSER AND DISCARD THE FIRST TWO TRIGGER PULLS OF ADHESIVE FROM EACH REFILL PACK/CARTRIDGE. 6. INJECT ADHESIVE INTO HOLE STARTING AT THE BOTTOM UNTIL 1 2 TO 2 3 FULL USE MIXER FILLER TUBE EXTENSIONS WHEN NEEDED TO REACH THE BOTTOM OF THE HOLE. 7. UNLOCK DISPENSER. 8. INSERT ALL —THREAD ROD OR REBAR DOWEL TWIST DURING INSTALLATION. 9. ANCHOR MAY BE ADJUSTED DURING SPECIFIED GEL TIME. DO NOT DISTURB ANCHOR BETWEEN SPECIFIED GEL AND CURE TIMES. 10. AFTER FULL CURE TIME, APPLY SPECIFIED TORQUE AS REQUIRED TO SECURE FASTENED ITEM.DO NOT EXCEED SPECIFIED MAXIMUM TORQUE. SECTION A SCALE: 1 /2" = 1'—O" NEW BASIN WATER LINE —NEW INFINITY EDGE PORTION OF EXISTING POOL WALL TO BE REMOVED POOL DECK NOTE: PROVIDE 18" MIN. SPLICE AND 3" MIN. CONCRETE COVER 6" . 2' i 6" CONCRETE SLAB W/ #3 0 9" EACH WAY BUILDIIG APPRUVED DRAWING BY G.I.A SWIMMING POOL DESIGN,INC 786-554-7804 tll l l I / � z cv W I Q = W CC)* ul't2 ° � F- �,O_ � se ; 0 ^� N %I //,� \\j NEW BASIN POOL WATER LINE WALL DE PROVIEXISTING HOR. & VERT �j POOL WALL \\ i = EXISTING Z PROVIDE #3 ® 9" I POOL WALL j HOR. & VERT N\1 ILL I IL %. / . /�. /� i /i /� ✓/.//.�//,\�/� PROVIDE #3 09" ifl HOR. & VERT 6" CONCRETE SLAB W/ #3 0 9" EACH WAY a EXISTING POOL FLOOR USE # 3 0 9" O.0 EACH WAY DRILL v 6 MIN. INTO EXISTING CONCRETE USE # 3 ® 9" O.0 EACH WALL AND SET BAR IN EPDXY WAY DRILL 6" MIN. INTO GROUT BY "HILTY" HIT HY 150 MAX M EXISTING CONCRETE FLOOR MIN. SPLICE 18" AND SET BAR IN EPDXY GROUT BY "HILTY" HIT HY 150 MAX MIN. SPLICE 18" DETAIL 1 TOP VIEW SCALE: 1 /2" = 1'—O" SECTION B SCALE: 1 /2" = 1'-0" O � z z� M 00 U Oo 00 � o pq o OF � O m N d k Ix a c U fsa O 41 a � o N r--� W a E-+ a WO t�aaU c W W c N O SHEET: 3 OF 4 EXISTING 200 AMP. MAIN DISC. ELECTRICALFo METER FPL SERVICE EXISTING 200 AMP. ELECT. PANEL 3 # 2/0 THWN 1 # 6 G. EXISTING 2 # 12 THWN 1 P 20 AMP. 1 # 12 THHN CU. GROUND. EXISTING GFI RECEPTACLE 6' MIN. 20' MAX. FROM WATER LINE I-1 3#12THWN PDA CONTROL 300 W CENTER TRANSFORMER 2 HP/230 V. POOL RECIRCULATION PUMP TWO SPEED SALT SYSTEM 2 HP BLOWER 230 V 2#12THWN 2P 20 AMP.GFCI BREAKER (PUMP) POOL PUMP WILL 2 # 12 THWN COMPLY WITH 2O14 2 P 20 AMP.(BLOWER) FBC E 403.9. AND NEC 2011 403.32 2#12THWN 1 P 20 AMP.(UGTH) 1 # 12 THWN CU. GROUND. RISER DIAGRAM NOTE; PROVIDE #8 BARE COPPER BOND WIRE FROM LIGHT TO POOL STEELWHERE A CONCRETE DECK IS NOT PROVIDED, PROVIDED A # 8 BARE COPPER BOND WIRE FROM THE POOL STEEL TO THE EQUIPMENT TO PANEL. WHERE A CONCRETE SLAB IS PROVIDED , THE BOND WIRE SHALL BE CONNECTED FROM THE POOL STEEL TO REINFORCING MESH CONTINUOUS TO THE #5 REINFORCING BAR IN THE PERIMETER SLAB FOOTING. A BOND WIRE SHALL THEN BE CONNECTED FROM THE PERIMETER STEEL TO THE EQUIPMENT TO THE ELECTRICAL PANEL ELECTRICAL NOTES: 1. ALL POOL ELECTRICAL WORK SHALL BE ACCOMPLISHED IN COMPLIANCE WITH 5TH EDITION (2014) RESIDENCE BUILDING CODE. 2. ALL ELECTRICAL GROUNDING AND BONDING MUST BE CONFORM WITH THE FLORIDA BUILDING CODE. 3. NO OVERHEAD WIRING SHALL BE LOCATED WITHIN 10'.O" OF POOL'S WATER EDGE. 4. SHOULD THE ELECTRICAL RISER DIAGRAM NOT ACCURATELY DEPICT REQUIRED WORK, A REVISED DRAWING SHALL BE SUB-MITTED AND APPROVED SHOWING EXPECTED AS BUILT CONFIGURATION WITH ADDITIONAL SERVICE AND LOAD CALCULATIONS, IF NECESSARY. 5. ALL ELECTRICAL EQUIPMENT NOT SUITABLE FOR EXPOSURE TO THE ELEMENTS SHALL BE ENCLOSED IN A WEATHERPROOF CONTAINER ALL PUMPS, HEATERS AND RELATED POOL EQUIPMENT SHOWN ON THESE PLANS ARE SATISFACTORY FOR EXPOSURE TO THE ELEMENTS. NOTE: BOND WIRE # 8 TO BE SECURED TO CONTINUOUS SINGLE # 8 COOPER BONDED IN FOUR POINT(360-) AROUND D_ POOL & SPA WITH APPROVED SPLIT 0- BOLT CONNECTORS o Z CONT.WIRE # 8 COOPER TO POOL EQUIPMENTS co 1NON METALLIC f TO JUNCTION BOX NOTE: BOND WIRE # 8 TO BE SECURED TO STEEL WITH APPROVED CLAMP. TO BE ENCASED IN POOL FOUNDATION MIN. 3" OF COVER AROUND CLAMP 18" MIN. 24" MAX. NEW 15 W 12 V BASIN LIGHT (4) NOTE: PROVIDE CONTINUOS SINGLE # 8 CO( BONDED IN FOUR POINT(360" AROUND POOL & SPA NOTE THIS DESIGN IS AN z ALTERNATIVE AND/OR EQUIVALENT TO COMPLIANCE WITH N.E.0 2011 ART. 680.26 C. POOL BOND & UNDERWATER LIGHT DETAIL No SOME .B 1 NEW 25W 12V LED SPA LIGHT NEW 4OW 12V LED POOL LIGHT NOTE BOND WIRE # 8 TO BE SECURED TO STEEL WITH APPROVED CLAMP. TO BE ENCASED IN POOL FOUNDATION MIN. 3" OF COVER AROUND CLAMP POOL BOND SCHEMATIC POOL DECK POOL COPING POOL WALL 1" PVC PIPE TO TRANSFORMER 1-1/2' PVC PIPE MIN. 16' NICHELESS LIGHT DETAIL AIR RELIEF CARTRIDGE POOL FILTER WITH 250 SQ.FT. OF SURFACE Ali IP. NOTE: THIS DESIGN IS AN ALTERNATIVE AND/OR EQUIVALENT TO COMPLIANCE WITH N.E.0 2011 ART. 680.26 C. TILE 4" MIN. FROM WATER LEVEL TO TOP OF LENS INTERIOR POOL FINISH (DIAMOND BRITE) NO SCALEEVIEW LA P ID R 0 E- /A ��. SALT NOTE: BALL VALVES MAY BE SUBSTITUTED FOR MULTIPORT VALVES WATEF CERAMIC THR( POOL P SIC,SQ 1,N QOOv R� OR-o" SQ RECIRCULATION PUMP TWO SPEED 2 HP WITH 100 GPM AT 60' TDH ISOMETRIC POOL DATA: POOL SPA BASIN TOTAL SURFACE AREA SQ.FT. 648.0 49.0 72.0 769.0 VOLUME GALLONS 20067 507.5 2423.5 22998 TURNOVER HOURS 3.35 0.08 0.40 3.83 PERIMETER (FEET) 1 108.0 28.0 76.0 212.0 DECK AREA ( SQ.FT) 1146.31 PLUMBING NOTES: 1. ALL POOL EQUIPMENT PIPING SHALL BE SCHEDULE 40, PVC-PW, NON -THREADED, NSF APPROVED SUPPORTED CONTINUOUSLY ON GROUND OR ON MAXIMUM 4'-0" CENTERS WITH CLEVIS HANGERS. 2. ALL SUCTION PIPING SHALL BE 2" DIAMETER AND ALL PRESSURE PIPING 1-1/2" DIAMETER UNLESS OTHERWISE NOTED. 3. POOL WATER DISPOSAL SHALL BE IN ACCORDANCE WITH LOCAL BUILDING DEPARTMENT REQUIREMENTS. 4. ANTI VORTEX MAIN DRAINS SHALL HAVE ITS PLATE SECURELY FASTENED WITH TAMPERPROOF SCREWS. 5. POOL VACUUM SHALL HAVE SPRING LOADED CAP IN ACCORDANCE WITH THE FLORIDA BUILDING CODE. 6. ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE -PLUMBING SECTION 309 AS IT PERTAINS TO BUOYANCY. 7. THE WATER VELOCITY THOUGH ALL SUCTION PIPING SHALL BE LESS THAN 8 FEET PER SECOND. 8. THE WATER VELOCITY THROUGH ALL PRESSURE PIPING SHALL BE LESS THAN 10 FEET PER SECOND. 9. ALL PIPING SHALL BE SUITABLE FOR EXPOSURE TO ULTRA VIOLET RADIATION AND NORMAL OPERATING TEMPERATURES. ADJUSTABLE LID SKIMMER DETAIL NO SCALE iNCRETE BASKET 5 SQ.IN.) ON UNE SAME SIZI AS PUMP SUCTION 2" HYDROSTATIC RELIEF TUBE . ONLY ONE REQUIRED MAINDRAIN DETAIL NO SCALE gPsv O DRAWING BY G.I.A SWIMMING POOL DESIGN,INC RTO@GIAPOOLDESIGN. 786-554-7804 ' L a (s-� z 1►--� w 4.4 o� 2 HP BLOWER ~ (230 V) W un H � Z � en a w o z �o OLL �•� r ,1i $ c� r - to 0 , ui w � w �s Y, a o,z� Z Fo •0 ----- ,• 5 `moo �. /J®/1liF4��6\`e`� c+� O z a� Q� 'ten Mcn RJ 00 M zw en�wW) .--, in zC14�-+ o W en 1 /1-1 as � U W c►-,o 00 00 Q' O pq o Efl tn 00 Opa4� {� " a N U H OF, 4 a �D - o � , ', a w a F, a a �aaav 00 Wkn W En O N O SHEET: 4 OF 4 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 PERMIT APPLICATION P BUILDING ❑ ELECTRIC ❑ ROOFING FRC 20'-4- Master Permit No:'''. Sub Permit No. I REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Nam Fee Simple Titleholder): l �J /y( 1 G �� �V Phone#:36' ; Address:. City: P10State: f Zlp: ��V ch Tenant/Lessee Name: Phone#: Email: Orr) C CONTRACTOR: Company Name: / §/ ( c 0' % e Phone#: � `'- Address: / _ City: /� ��/ l,� <� State: 1'—xoe"Clad Zip: Qualifier Name:' F� /� r ffa'/i-'�` .+� Phone#: State Certification or Registration #: Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: > /'Fr Z//e'.'/ Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Training/Education Education Fee $ Double Fee $ Technology Fee $ g/ — Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) OUTDOOR SWIMMING BARRIER COMPLYING WITH 6TH EDITION (2017) R4501.17.1.1 THROUGH R4501.17.1.14 R4501.17Residential swimming barrier requirement. Residential swimming pools shall comply with Sections R4501.17.1 through R4501.17.3. Exception: A swimming pool with an approved safety pool cover complying with ASTM F1346. R4501.17.1Outdoor swimming pools. The top of the barrier shall be at least 48 inches (1219 mm) above grade measured on the side of the barrier which faces away from the swimming pool. The maximum vertical clearance between grade and the bottom of the barrier shall be 2 inches (51 mm) measured on the side of the barrier which faces away from the swimming pool. Where the top of the pool structure is above grade the barrier may be at ground level or mounted on top of the pool structure. Where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be 4 inches (102 mm). R4501.17.1.2 The barrier may not have any gaps, openings, indentations, protrusions, or structural components that could allow a young child to crawl under, squeeze through, or climb over the barrier as herein described below. One end of a removable child barrier shall not be removable without the aid of tools. Openings in any barrier shall not allow passage of a 4—inch—diameter (102 mm) sphere. R4501.17.1.3 Solid barriers which do not have openings shall not contain indentations or protrusions except for normal construction tolerances and tooled masonry joints. R4501.17.1.4 Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is less than 45 inches (1143 mm), the horizontal members shall be located on the swimming pool side of the fence. Spacing between vertical members shall not exceed 1-3/4 inches (44 mm) in width. Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed 1-3/4 inches (44 mm) in width. R4501.17.1.5 Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members is 45 inches (1143 mm) or more, spacing between vertical members shall not exceed 4 inches (102 mm). Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed 1-3/4 inches (44 mm) in width. R4501.17.1.6 Maximum mesh size for chain link fences shall be a 2-1/4—inch square (57 mm) unless the fence is provided with slats fastened at the top or bottom which reduce the openings to no more than 1-3/4 inches (44 mm). R4501.17.1.7 Where the barrier is composed of diagonal members, the maximum opening formed by the diagonal members shall be no more than 1-3/4 inches (44 mm). R4501.17.1.8 Access gates, when provided, shall be self —closing and shall comply with the requirements of Sections R4501.17.1.1 through R4501.17.1.7 and shall be equipped with a self —latching locking device located on the pool side of the gate. Where the device release is located no less than 54 inches (1372 mm) from the bottom of the gate, the device release mechanism may be located on either side of the gate and so placed that it cannot be reached by a young child over the top or through any opening or gap from the outside. Gates that provide access to the swimming pool must open outward away from the pool. The gates and barrier shall have no opening greater than 1/2 inch (12.7 mm) within 18 inches (457 mm) of the release mechanism. Where a wall of a dwelling serves as part of the barrier, one of the following shall apply. 1.All doors and windows providing direct access from the home to the pool shall be equipped with an exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 dBA at 10 feet (3048 mm). Any deactivation switch shall be located at least 54 inches (1372 mm) above the threshold of the access. Separate alarms are not required for each door or window if sensors wired to a central alarm sound when contact is broken at any opening. Exceptions: a.Screened or protected windows having a bottom sill height of 48 inches (1219 mm) or more measured from the interior finished floor at the pool access level. b.Windows facing the pool on floor above the first story. c.Screened or protected pass —through kitchen windows 42 inches (1067 mm) or higher with a counter beneath. 2.AI1 doors providing direct access from the home to the pool must be equipped with a self —closing, self —latching device with positive mechanical latching/locking installed a minimum of 54 inches (1372 mm) above the threshold, which is approved by the authority having jurisdiction. 3.A swimming pool alarm that, when placed in a pool, sounds an alarm upon detection of an accidental or unauthorized entrance into the water. Such pool alarm must meet and be independently certified to ASTM Standard F2208, titled "Standard Safety Specification for Residential Pool Alarms,"which includes surface motion, pressure, sonar, laser, and infrared alarms. For purposes of this paragraph, the term ''swimming pool alarm"does not include any swimming protection alarm device designed for individual use, such as an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water. Where an aboveground pool structure is used as a barrier or where the barrier is mounted on top of the pool structure, and the means of access is a ladder or steps, the ladder or steps either shall be capable of being secured, locked or removed to prevent access, or the ladder or steps shall be surrounded by a barrier which meets the requirements of Sections R4501.17.1.1 through R4501.17.1.9 and Sections R4501.17.1.12 through R4501.17.1.14. When the ladder or steps are secured, locked or removed, any opening created shall not allow the passage of a 4—inch—diameter (102 mm) sphere. SCOPE OF WORK: EXISTING U.G. ELECTRICAL SERVICE EXISTING 200AMP. ELECTRICAL METER EXISTING 200AMP. ELECTRICAL PANEL EXISTING 4FT HIGH CHAIN LINK FENCE & SINGLE GATE WITH SELF CLOSING AND SELF LATCHING DEVICE. W/LOCK DEVICE ® 54" FROM GRADE LEVEL EXISTING 4 FT HIGH CHAIN LINK FENCE (TO BE USED AS PART OF POOL BARRIER) BRICK ON SAND POOL DECK EXISTING POOL TO BE REMODELED UNDER THIS PERMIT— SEE SCOPE OF WORK NOTE IN THIS PAGE — REMODELING EXISTING POOL INCLUDES: 1. BUILD NEW SPA ATTACHED TO EXISTING POOL. 2. BUILD NEW INFINITY BASIN ATTACHED TO EXISTING POOL. 3. CHANGE DEPTH OF EXISTING POOL FROM 7'-0" TO 5-0" AT DEEP END 4. INSTALL NEW POOL PIPING AND FILTRATION SYSTEM 5. INSTALL NEW POOL LIGHTS 6. PROVIDE NEW POOL BONDING R=25.00' A=25.07'PL S ��_--- Ap ed \ Date \ 1� 0 to cD O T TWO STORY IA/ AREA O ASPHALT DRIVEWAY — 1 NJITH ALL F 1. 4 rm I AfA Cdl i � XISTING WATER LINE i EXISTING DRAIN FIELD i r-- EXISTING SEPTIC TANK i I ; � PLA TER 1 � � DRAW BY SwntVkNc POOL oESIGNE 305.741.3442 A CA o0 M i l p z � o �o ONE STORY C.B.S. � co RESIDENCE 1460 # � OOL EQUIPMENT PDA C,®_____.�J?�`�t„re,. CONTROL CENTER � _p � POOL EQUIPMENT � ���`at 0 EXISTING 4FT HIGH CHAIN LINK % FENCE &SINGLE GATE WITH SE A 0, ® � v ", 2 CLOSING AND SELF LATCHING � �j'•, �' � BR CK � - ST DEVICE. W/LOCK DEVICE ®54" I,• 55\ee � ' FROM GRADE LEVEL pFt�F� DECO —DR IN a,,-, '� //�!!`�1lI1e\\°\`� N 1 —6„ BRICK 8 49' PAVERS !, EXISTING 4 FT HIGH CHAIN LINK FENCE (TO BE USED AS PART OF 5POOL BARRIER) H FEEEI I//// =�//' / X ' NEW 7X7 FT SPA 1, \ WOOD CO DOCK BOAT \ �, CONC. °wJ' n,� .; LIFT �� SEA WALL x EXISTING GRADE WITH SLOPE R=200.00 `�. MAX. 1': 4' ' z x\ ' x ' \i PROVIDE ALARMS ALL WINDOWS AND DOORS WITH ACCESS TO THE POOL ON ANY WALLS OF THE HOUSE USED AS PART OF THE BARRIER COMPLYING WITH 6TH EDITION (2017) FBC R45 01.17.1.9 REFER TO POOL BARRIER CODE NOTES IN THIS PAGE LEGAL: RE —PLAT OF TR C MIAMI SHORES BAY PARK ESTS PB 64-97 LOT 15 BILK 5 LOT SIZE IRREGULAR OR 13702-870 0688 1 CDC 25631-2753 05 2007 1 36.82' NEW 18 FT NEW 36'x2' a,,( ra ( /A)S / "T/ /&_77d k's ' SITE PLAN - SCALE: 1"=20'—O" REV. DATE:08/30/ 1 6 M N 00 U M M —+ "� ►-� OM ZN U W O Apo as 0A� 00 00 ` ' o V1 00 c a N U � �D o N w O W �4 a un N W WW OO rxwaU SHEET: 1 OF 4 C EXISTING RESIDENCE EXISTING RESIDENCE 8.90' NG OF FI EXI A RP 8.90' EP CL OC -20 EE FR P L DIG \ JW N N PROVIDE 00 be 1 Ji 4"X2" DECO = DRAIN 9 N PROVIDE 4"X2" 001I001I EXISTING 1'-5" DECO DRAIN a. X. W a. J V BRICK PAVERS EXISTING 1'-6"- 8 49' z 0 1= N POOL DECK N w SLOPE Y- w # 8 TO POOL PUMP EXISTING 19'-4" 6' 1 I I I I , S INLET INLET INLET VACUUM \ INLET INLET IIINLT -- -----~---r--r-- I I I I I I I I I I I I I 1 1 1 EXISTING IMPERVOUS, SLIP PROM TES�I AR__+ -_ , 8 90' RESISTANT CONCRETE " EXISTING POOL W/ # 3y 019 ACH WAY �— PAVER DECK SLOPED 1 /8 X NEW (4) - Ir-"T -r- -- '-6 FT SLOPE AWAY FROM POOL—" STEPS 40W 12V LED POOL ---------------- -- -- T------------ LIGHT II 11 1' 1' 1' EXISTING POOL _ NEVI�_MAINIDRAIN___ POOL DECK " RISE POOL jFLOOR FROM -I J SLOPE Y' 00 3 -0 DEEP /� NOTE: BOND WIRE TO BE SECURED _ __----------11------------------------ TO EXIST. STEEL WITH APPROVED CLAMP. OPTIONAL: PROVIDE 4 PROVIDING MIN. 3" OF CONCRETE -1 COVER AROUND CLAMP CONTRASTING TILE OR BULLNOSE TILE ON STEPS & BENCH EDGE ------------- --------------- ---�- r o;NEW $WIMOUT--- 8.49' - P --- ---- ,-- " M Xa B LOW — - R--LINE 1 ry PROVIDE HANDRAIL �� II - � II III1111�11 9' 10'-4"- -1PRO)h )~_6t _C�0N1CRETE_ SLAB_ 3-4 W/; 3; 0 9"; EACH WAYI ----- 1 --I --1 - --- -- �I C ll F + E 3 A , I ` i C4 2'-0" D�EP NEW BASIN 4 - EP -�F 6 i I ` DENOTE NEW 1OW 12V LED POOL LIGHT LANDSCAPING LIGHTS (TOTAL 8) a a d d ° a 5.20' a a CONC. SEA WALL a d p d D d ° d d a POOL JIPMEN FOR P11 —14'- NOTE: THE GRAPHIC R PIPE ROUTI OF PIPING TO POOL E DIFFER FRC JET II JET JET JET JET . j JET DRAW BY G I AIL SW-"NG POOL_ DESIGNS 305.741.3442 roberto@giapooldesign.com 0 �•j ;E N 00 rT1 M M Do un A V] r l H c� v L W H E-L Ln DECK: NEW BRICK ON SAND O V o W Q C NId o A4 "r ate_ F���n yA z1' °� ^� �-{pa F - �e 0 SPA FLUSHLID Fes§ St u �K TO POOL { Pj` C D FIRST STEP-4 MUST COVER 240 SQ IN. MIN. 25W 12V�.L,ED SPA LIGHT " EW MAIN DRAIN Al�1. Dg -4 i DETAIL 1 ! (4)15W 12V LED `® It NICHELESS LIGHT E NOTE: PROVIDE. CONTINUOUS SINGLE # 8 COOPER 3-4 BONDED IN FOUR POINT (360^) DETAIL 1 USE # 3 09" O.0 EACH WAY DRIL INTO EXISTING CONCRETE WALLA' �. AROUND POOL & SPA * PROVIDE WELL BAR IN EPDXY GROUT BY "HILTY" T HY5c, COMPACTED FILL W/ MAX 150 MAX MIN. SPLICE 18" f X SLOP 1':4' TO MEET `4 36' EXISTING GRADE LPROVIDE HANDRAIL POOL PLAN NOTE: THE SCOPE OF WORK UNDER THIS PLAN REVISION ONLY INCLUDED: 1- PROVIDE 6" CONCRETE SLAB AT DEEP END OF EXISTING POOL TO CHANGE NOTE: CONTRACTOR SHALL VERIFY ALL SETBACKS FROM THE DEPTH OF POOL FROM 7'-0" TO 6'-0" MAX. PROPERTY LINES AND STRUCTURES PRIOR TO EXCAVATION. SHOULD ANY SETBACKS BE LESS THAN THE MINIMUN 2- INSTALL NEW BENCH AT DEEP END OF EXISTING POOL REv REQUIREMENTS, EITHER BY OWNER OR BUILDING OFFICIAL, THE a ENGINEER SHALL BE NOTIFIED. 3- THE INSTALLATION OF HELICAL PILES AT EXISTING POOL BASIN, EXISTING SPA AND PROPOSAL POOL DECK RETAINING WALL. DATE: 1 1 /02/ 1 8 M N M N O M O� M M U W c"po 5 a ocl 00 00 pq o 00 a w o x O O o " N a E.{ M � a r N Zs�� SHEET: 2 OF 4 EPDXY NOTES HILTI HIT HY-150 MAX INJECTION ADHESIVE ANCHOR 1. DRILL HOLES WITH ANSI B212.15 MATCHED TOLERANCE CARBIDE TIPPED DRILL BITS WITH DRILL IN ROTO—HAMMER MODE. DIAMOND CORING HOLES IS NOT PERMITTED. 2. DRILLED HOLE SPECIFICATIONS (DIAMETER & DEPTHI) SHALL COMPLY WITH HILTI SPECIFICATIONS OR ICC ESR 3. ALLOWABLE LOADS MAY BE INCREASED BY UP TO 33-1 3% FOR SHORT—TERM WIND OR SEISMIC LOAD RESISTANCE IAW ICC ESR UNLESS NOT PERMITTED BY THE APPLICABLE BUILDING CODE. 4. WHEN CONDUCTED, PROOF TEST ANCHORS IN THE FIELD TO 150-200% OF HILTI PUBLISHED ALLOWABLE TENSION LOAD UNLESS NOTED OTHERWISE IN A PROOF TEST LOAD TABLE. TORQUE TESTING IS NOT PERMITTED. 5. ANCHORS MAY BE INSTALLED IN DAMP HOLES IAW ICC ESR. INSTALLATION IN HOLES WITH STANDING WATER IS NOT PERMITTED. 6. ANCHORS SHALL BE TIGHTENED WITH A CALIBRATED TORQUE WRENCH. USE OF AN IMPACT WRENCH IS NOT PERMITTED. 7. CONTACT HILTI TECHNICAL SUPPORT AT 1-800-879-8000 FOR ADDITIONAL ASSISTANCE WITH HIT HY-150 MAX ANCHOR INSTALLATIONS. 8. INSTALLATION INSTRUCTIONS: A. FOR HIT HY-150 ADHESIVE WITH ALL —THREAD ROD OR REBAR DOWEL: 1. DRILL ANCHOR HOLE WITH A CARBIDE BIT (SEE NOTE 1 ABOVE), TO SPECIFIED EMBEDMENT DEPTH. 2. CLEAN HOLE IN ACCORDANCE WITH HILTI SPECIFICATIONS OR ICC ESR. 3. PUT ADHESIVE REFILL PACK INTO DISPENSER HOLDER. REMOVE CAP COVERING THREADED PROJECTION. 4. SCREW ON STATIC MIXER NOZZLE. 5. PUT HOLDER/CARTRIDGE INTO APPROPRIATE DISPENSER AND DISCARD THE FIRST TWO TRIGGER PULLS OF ADHESIVE FROM EACH REFILL PACK/CARTRIDGE. 6. INJECT ADHESIVE INTO HOLE STARTING AT THE BOTTOM UNTIL 1 /2 TO 2/3 FULL. USE MIXER FILLER TUBE EXTENSIONS WHEN NEEDED TO REACH THE BOTTOM OF THE HOLE. 7. UNLOCK DISPENSER. 8. INSERT ALL —THREAD ROD OR REBAR DOWEL. TWIST DURING INSTALLATION. 9. ANCHOR MAY BE ADJUSTED DURING SPECIFIED GEL TIME. DO NOT DISTURB ANCHOR BETWEEN SPECIFIED GEL AND CURE TIMES. 10. AFTER FULL CURE TIME, APPLY SPECIFIED TORQUE AS REQUIRED TO SECURE FASTENED ITEM.DO NOT EXCEED SPECIFIED MAXIMUM TORQUE. BRICK COLORS AND PROVIDE T—E 8"X8" CONC. PATTERNS TO BE SELECTED / 1 # CAP W 5 CONT. BY OWNER/ BUILDER 8.49' POOL DECK EXISTING GRADE EXISTING 12" POOL CONCRETE FLOOR USE # 3 ® 9" O.0 EACH WAY DRILL 6" INTO EXISTING CONCRETE FLOOR AND SET BAR IN EPDXY GROUT BY "HILTY" HIT HY 150 MAX MIN. SPLICE 18" USE # 3 ® 9" O.0 EACH WAY DRILL 4" INTO EXISTING CONCRETE WALL AND SET BAR IN EPDXY GROUT BY "HILTY" HIT HY 150 MAX MIN. SPLICE 18" POOL COPING X a 7BEYOND POOL BENCH N a PROVIDE #3 ® 9" I. HOR. & VERT z F cn w! NEW 6 CONCRETE SLAB W/ #3 ®9" EACH WAY w U ANTI VORTEX " L MAINDRAIN EXISTING PILE 14' 12" OPTIONAL: PROVIDE POOL COPING 6" 6" CTILE ONTRON STEPSL& BENCHE OR LLNOSE GEE 10" 10" 1-6. / —POOL DECK � 1 e #3 ® 9" HOR. & VERT / -*r 18 NEW SPA BENCH BEYOND 6" FOAM 00 PORTION OF EXISTING POOL'//�/' SLAB TO BE CUT IN ORDER TO INSTALL NEW 2" HYDROSTATIC RELIEF VALVE 2" H RELI E IN WASHED BED ROCK EXISTING PILE SECTION A SCALE: 1 /2" = 1'—O" N- ANTI VORTE;l_ MAINDRAIN wwesm_gw_� ®ll`�fm co EXIST. #3 ® 9" HOR. & VERT LEXIST.12" CONCRETE SU41 2 W/ #3 ® 6" EACH WA TOPAND BOTTOM LEXIST. # 3 ® 9" O.0 EACH WAY4" INTO EXISTING CONCRETE WALSET BAR IN EPDXY GROUT BY "HHIT HY 150 MAX MIN. SPLICE 18"EXISTING SEE DETAIL 2 POOL WALL USE # 3 0 9" O.0 EACH WAY DRILL 4" INTO EXISTING NOTE: PROVIDE 18" MIN. SPLICE CONCRETE FLOOR AND SET AND 3" MIN. CONCRETE COVER BAR IN EPDXY GROUT BY "HILTY" HIT HY 150 MAX MIN. SPLICE 18" '--Wdb/' F/iA'(rT SNUB BASE NEW BASIN WATER LINE i\// NEW INFINITY EDGE SECTION C PORTION OF EXISTING POOL ----` N.T.S., WALL TO BE REMOVED PROVIDE NEW 3.5"0 HELICAL „ POOL DECK PILE WITH STANDARD UNDERjj PINNING BRACKET \; (SEE DETAIL 2)LJ \/ LPOOL WATER LINE EXISTING WALLWITH #3 ® 9 PROVIDE 1/2" THINSET HOR. & VERT FOR ALL PERIMETER BRICKS " EXISTING EXIST.# 3 ® 12" O.0 EACH WAY POOL DECK 8'49 POOL WALL TOP AND BOTTOM —DRILL 6" //\//\////�//�/%\ MIN. INTO EXISTING CONCRETE z FLOOR AND SET BAR IN EPDXY w GROUT BY "HILTY" HIT HY 150 °r .,f ..l \\,/\\/\\/\\/\\\\ - MAX MIN. SPLICE 18" 12" x 36" GRADE BEAM GB-2 (SEE PLAN & SCHEDULE) XISTING GRADE PILE ON SITE PRIOR ORDER) A EXISTING 12" CONCRETE EXIST. #3 ® 9" POOL FLOOR HOR. & VERT 8"x 8"x 3 4 " TOP PLATE W/ 4 # 3/4" HEADED WELDS: ALL WELDS SHALL CONFORM TO AWS STUDS WELDED AS SHOWN. STANDARDS AND SHALL BE MADE BY PROPERLY I CERTIFIED WELDERS. ALL ELECTRODES SHALL BE EXISTING PILE E70XX. ALL WELDS SHALL BE WIRE BRUSHED AND PAINTED TO ASSURE WEATHER RESISTANCE. IST. 12" CONCRETE SLAB 3. " 0 I W #3 ® 6" EACH WAY TOP AND BOTTOM HELICAL PILES 3.5" 0I HELICAL PILE EE DETAIL 2 SECTION D SCALE: 1 /2" = 1'-O" SE TI O N B SCALE: /2" = 1'-0" 6" 2' i IOLTWAlL ..:.. DRAW BY GlAlk SW"ANG POOL DESIGNS 305.741.3442 co P P pie . Sk \`°fit f I �•ac�.� EXIST. # 3 ® 9" O.0 EACH WAY 6" MIN. INTO EXISTING CONCRETE NOTE: PROVIDE 18" MIN. SPLICE WALL AND SET BAR IN EPDXY AND 3" MIN. CONCRETE COVER GROUT BY "HILTY" HIT HY 1;'?fUX MIN. SPLICE 18" DETAIL 1 TOP VIEW SCALE: 3/4" = 1'-0" K3 . , NOTE: THE SCOPE OF WORK UNDER THIS PLAN REVISION ONLY INCLUDED: 1— PROVIDE 6" CONCRETE SLAB AT DEEP END OF EXISTING POOL TO CHANGE THE DEPTH OF POOL FROM 7'-0" TO 6'-0" MAX. 2\ 2— INSTALL NEW BENCH AT DEEP END OF EXISTING POOL 3— THE INSTALLATION OF HELICAL PILES AT EXISTING POOL BASIN, EXISTING SPA AND PROPOSAL POOL DECK RETAINING WALL. IZE V . DATE: 1 1 /02/ 1 6 M N M N UM M,� w o w ;� U W 0 �Oo A-; o0AIt SHEET: 3 OF 4 SOIL STATEMENT BASED ON THE INFORMATION OBTAINED FROM "ALL STATE ENGINEERING & TESTING CONSULTANTS, INC." THE PRESENCE OF LAYERS OF VERY LOOSE SLIT AND ORGANIC MATERIALS OF VARIED THICKNESS, MAKES THE SITE LESS APPROPRIATE FOR CONSTRUCTION USING REGULAR METHOD AT THE EXISTING GRADE FOR THE PROPOSED STRUCTURE, THEREFORE: THE FOLLOWING FOUNDATION SYSTEMS WERE SELECTED: L-3.5" DIAMETER, HELICAL PILES OF SUFFICIENT DEPTH TO PROVIDE A MINIMUM BEARING CAPACITY OF 15 TONS EACH STRUCTURAL NOTES 1.-ALL PILES SHALL BE 3.5" DIAMETER HELICAL PILE SUFFICIENT DEPTH TO PROVIDE A MINIMUM BEARING CAPACITY INDICATED 2.- ALL CONCRETE SHALL DEVELOP A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 5000 PSI. 3.- ALL REINFORCING STEEL SHALL HAVE A MINIMUM YIELD STRENGTH OF 60,000 PSI. 4.- ALL PILES SHALL EMBED A MINIMUM OF 4" INTO PILE CAPS. 5.- ALL PILE REINFORCING STEEL SHALL BE CONNECTED TO BOTTOM FLOOR REINFORCING WITH MINIMUM 18" LAPS AND APPROVED CONNECTORS. GENERAL NOTES. 1. ALL FLOORS AND WALLS OF POOL TO BE GUNITE APPLIED CONCRETE A 28 DAY MINIMUM COMPRESSIVE STRENGTH OF 5.000 PSI. 2.- ALL REINFORCING STEEL TO CONFORM TO ASTM 615 GRADE 60. 3.- ALL POOL PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL WHICH LOGO PRINTED. 4.- FILTER BACKWASH SHALL COMPLY WITH LATEST FBC. 5.- POOL SHALL BE BUILT ON 3.5" DIAM HELICAL PILES BASED UPON THE RECOMMENDATIONS CONTAINED IN THE GEOTECHNICAL REPORT PREPARED BY "ALL STATE ENGINEERING & TESTING CONSULTANTS„ INC." 6.-IN ALL CASES THE POOL CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO PROTECT EXISTING STRUCTURES FROM FAILURE BY SHORING, UNDERPINNING OR ANY OTHERS METHOD IF REQUIRED. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURE. 7.-THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACK AREAS. PLOT PLANS NOT PREPARED FROM LEGAL SURVEYS OF THE EXISTING LOT AND RESIDENCE ARE SO INDICATED. POOL CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES IF NECESSARY. CONTRACTOR AND/OR OWNER SHALL VERIFY LAYUOT SHOWN AND ALL DIMENSIONS PRIOR TO CONSTRUCTION. 8.- CONTRACTOR SHALL ESTABLISH LOCATIONS OF UTILITIES AT THE SITE. MINIMUM CLEARANCE DIMENSIONS SHALL BE HELD AND SHALL BE AS REQUIRED BY THE LOCAL REGULATORY AGENCY IN GENERAL. HOLD A DISTANCE OF 10 FEET FROM OVERHEAD ELECTRIC LINES TO OPEN POOL WATER AND 10 FEET FROM UNDERGROUND ELECTRIC LINES. 9.- POOL SLIDES TO BE INSTALLED IN ACCORDANCE WITH LATEST EDITION OF CONSUMER PRODUCTS SAFETY COMMISSION,W.D.C. 10.- MINIMUM 4'-0" HIGH IS FENCE RECOMMENDED AROUND ALL POOL IN UNSCREENED AREAS 11.- WHERE POOLS ABUT OR ARE PLACE NEARBY SEAWALLS OR BULKHEADS SPECIAL CARE SHALL BE EMPLOYED. THE WALLS SHALL BE IN GOOD CONDITIONS NOT PERMITTING ANY SHIFTING OR REMOVAL OR LOOSENING OF THE SUPPORTING SOIL AWAY FROM POOL IF THE WALLS DO NOT FULLY CONTAIN THE SIOL BEHIND THEM, THEY SHALL BE REPLACED OR REPAIRED. CONTINUAL MAINTENANCE OF THE WALLS IS REQUIRED OF THE PROPERTY OWNER WHEN EXCAVATING FOR THE POOL , THE SEAWALL TIEBACKS SHALL NOT BE CUT. WHERE CONCRETE DEADMEN FALL WITHIN THE EXCAVATION,NOTIFY THE ENGINEER FOR INSTRUCTIONS. 12.-THE CONTRACTOR SHALL BACK FILL THE POOL SHELL WITH CAUTION.THE PLUMBING SHALL NOT BE DISTURBED. BACKFILL SHALL BE ACCOMPLISHED WITH CLEAN SAND FREE OF ORGANIC MATERIALS AND SHALL BE PLACED 1N 12" THICK LAYERS. EACH LAYERS SHALL BE COMPACTED TO 90% OF THE SOIL MAXIMUM DENSITY BY TAMPING SOLIDLY. SOIL BELOW THE PATIO SHALL BE BY OTHERS. PILING DATA NOTE: SEE ATTACHMENT "ALL STATE ENGINEERING & TESTING CONSULTANTS, INC." REPORT PILE PILE CAPACITY PILE LATERAL PILE COMP TENSION CAPACITY DEPTH 3.5" 0 15 TONS 5 TONS N/A 22' HELICAL PILES EXISTING SPA --- 2) 1/2" EXPANSION IN EMBEDDED INTO :ONCIR I❑N TYPICAL INSTALLATION F❑UNDATION REPAIR BRACKET REAR vfz-y 1-1/4' SLOT TO FIT 1/2' HARDWARE 3' T SHAFT SIZE CAT. Nl/MBE/2 MINIMUM /JL TIMATE STRENGTH A109 I/1/G L OA P RS2875 C 1500840 72, 000 LBS 36,000 LBS RS3500 C 1500841 91,000 LBS 45,500 LBS NOTCS- 1, HOT DIP GALVANIZE PER ASTM A153-CLATEST REVISI❑N). 2. ASSEMBLE COMPLETE AS SHOWN IN SIDE VIEW. 3. RECOMMENDED ANCHOR SHAFT CUTOFF LEVEL BELOW THE BOTTOM OF THE FOOTING IS 14.5' FOR MAXIMUM LIFT DISTANCE. 4. MATERIAL SPECIFICATI❑NSi BRACKET BODY 1 3/8' THICK STEEL PER ASTM A572 GRADE 50 T-PIPE TUBE BODY + STEEL PER ASTM A572 GRADE 50, LATEST REV, T-PIPE PIPE i STEEL PIPE PER ASTM A500 LATEST REV. LIFTING STUDS: WILLIAMS FORM #11 GRADE 90, 5. A FACTOR OF SAFETY OF 2 YEILDS A SAFE WORKING LOAD. 6. THE CAPACITY OF THE UNDERPINNING SYSTEM IS A FUNCTION OF MANY INDIVIDUAL ELEMENTS, INCLUDING THE CAPACITY OF THE FOUNDATION, BRACKET, PIER SHAFT, HELICAL PLATE, AND BEARING STRATA, AS WELL AS THE STRENGTH OF THE FOUNDATION TO BRACKET CONNECTION AND THE QUALITY OF PIER INSTALLATION, UNDER PINNING BRACKET DETAIL (DETAIL 2) N.T.S NOTE: THE SCOPE OF WORK UNDER THIS PLAN REVISION ONLY INCLUDED: 1- PROVIDE 6" CONCRETE SLAB AT DEEP END OF EXISTING POOL TO CHANGE THE DEPTH OF POOL FROM 7'-0" TO 6'-0" MAX. 2- INSTALL NEW BENCH AT DEEP END OF EXISTING POOL 3- THE INSTALLATION OF HELICAL PILES AT EXISTING POOL BASIN, EXISTING SPA AND PROPOSAL POOL DECK RETAINING WALL. GRADE BEAM SCHEDULE MARK SIZE REINFORCEMENT GB-1 12"x12" (2) # 5 TOP, (2) #5 BOTTOM, & TIE # 3 0 12" O.C. GB-1 12"x36" (2) #55BOTTOM, & TIE # 3 12" O.C. RAILING ASSEMBLY SHALL RESIST A 200 LB. FORCE IN ANY DIRECTION AND REJECT A 4"0 OBJECT FOR METAL HAND RAIL & RAILING MANUFACTURED TO PROVIDE SHOP DRAWINGS TO BUILDING DEPARTMENT PRIOR INSTALLATION 12" LESS THAN 4" TYPICAL SPACING TO REJECT A 4"N OBJECT MANUFACTURED GUARDRAIL 12" 2" X 2" ALUM POST. ®48" O.C. MAX. SETIN A 12" DIA. 00 o X 2S -0" DEEP CONC. M z o FOOTING ® E.A. POST �I ,�o Lei(TYP) 12, ,--4- j.8.49' POOL DECK DRAW BY 4rml,ik SMAIANG POOL DESGNS 305.741.3442 IT W a 0 o—� C7 z Fe-eeell W M ,to con a 0 o W A W z o xl !l z ® pi 12"(TYP.) Lo \/\\//� 5.74' j EXISTING GRADE / //j//j�// TOP OF PILE -_ (VERIFY ON SITE \� �J �\ • /%\�/\`//� \ GRADE BEAM GB-1 (SEE PLAN & SCHEDULE) o TOP OF PILE4f (VERIFY ON SITE PRIOR ORDER)-�`�%\% \ / //// m \ 8"x 8"x 3/4 "TOP PLATE W/ 4 # 3/4" HEADED 12" x 12"/,//\ ///i w HECK L PILE STUDS WELDED AS SHOWN. GRADE BEAM GB-1 (SEE PLAN & SCHEDULE) 3/4" X 2" ALUM. ALUM. 8"x 8"x 3/4 "TOP PLATE BOTTOM BETWEEN POST W/ 4 # 3/4" HEADED REJECT 6"0 OBJECT STUDS WELDED AS SHOWN. 3.5' 0 PROVIDE # 3 ® 9" O.C. EACH WAY HELICAL PILE A SCAI_F. 1 /2" = V-0" DATE: 1 I /O 2/ 18 M N M N O M UCN w C> N � M U W 5'Oo N G o O O o U o H Irr-1 a rn aW Edo N W W a a a U SHEET: 3.2 OF 4 EXISTING 200 AMP. MAIN DISC. IRICAL O METER EXISTING 2 # 12 THWN 1 P 20 AMP. 1 # 12 THHN CU. GROUND. JANDY-AUTOMATION CENTER POOL PANEL EXISTING 60 AMP. REFER TO SITE 200 AMP. --,/--PLAN FOR LOCATION ELECT. PANEL -� 2P-60 AMP. PANEL "P" DISC. 3#6THWN 1# 8 (G)- 3 # 2/0 THWN IN 1" COND 1 # 6 G. 2P-20AMP.GFCI BREAKER (PUMP) 2P-20AMP.(BLOWER) 1 P-20AMP.(LIGTH) EXISTING GFI RECEPTACLE 6' MIN. 20' MAX. FROM WATER LINE SYSTEM 3 # 12 THWN 3.0 HP/230 V. POOL RECIRCULATION PUMP TWO SPEED 1 P-20 AMP.(LOW VOLTAGE) 2 BLOWER 230 V SERVICE POOL PUMP WILL COMPLY WITH 2O14 FBC E 403.9. AND NEC 2011 403.32 I HEREBY CERTIFY THAT THE EXISTING SERVICE AND PANEL HAVE ENOUGH CAPACITY TO ACCOMMODATE THE NEW/ADDED POOL EQUIPMENT LOAD NOTE; PROVIDE #8 BARE COPPER BOND WIRE FROM LIGHT TO POOL STEEL.WHERE A CONCRETE DECK IS NOT PROVIDED, PROVIDED A # 8 BARE COPPER BOND WIRE FROM THE POOL STEEL TO THE 300 W TRANSFORMER NEW 15 W 12 V BASIN LIGHT (4) (NICHELESS) EQUIPMENT To PANEL ELECTRICAL RISER DIAGRAM WHERE A CONCRETE SLAB IS PROVIDED , THE BOND WIRE SHALL BE CONNECTED FROM THE POOL STEEL TO REINFORCING (MESH N.T.S. CONTINUOUS TO THE #5 REINFORCING BAR IN THE PERIMETER SLAB FOOTING. A BOND WIRE SHALL THEN BE CONNECTED FROM THE PERIMETER STEEL TO THE EQUIPMENT TO THE ELECTRICAL PANEL. ELECTRICAL NOTES: 1. ALL POOL ELECTRICAL WORK SHALL BE ACCOMPLISHED IN COMPLIANCE WITH FBC 2017, 6TH EDITION, CHAPTER 42 2. ALL POOL ELECTRICAL WORKS, GROUNDING AND BONDING MUST BE CONFORM WITH THE NEC 2014. ART. 680 3. NO OVERHEAD WIRING SHALL BE LOCATED WITHIN 10'.0" OF POOL'S WATER EDGE. 4. SHOULD THE ELECTRICAL RISER DIAGRAM NOT ACCURATELY DEPICT REQUIRED WORK, A REVISED DRAWING SHALL BE SUB-MITTED AND APPROVED SHOWING EXPECTED AS BUILT CONFIGURATION WITH ADDITIONAL SERVICE AND LOAD CALCULATIONS, IF NECESSARY. 5. ALL ELECTRICAL EQUIPMENT NOT SUITABLE FOR EXPOSURE TO THE ELEMENTS SHALL BE ENCLOSED IN A WEATHERPROOF CONTAINER ALL PUMPS, HEATERS AND RELATED POOL EQUIPMENT SHOWN ON THESE PLANS ARE SATISFACTORY FOR EXPOSURE TO THE ELEMENTS. 6. RECEPTACLES SHALL BE LOCATED NOT LESS THAN 6 FEET (1829 MM) FROM THE INSIDE WALLS OF A STORABLE POOL, STORABLE SPA OR STORABLE HOT TUB. IN DETERMINING THESE DIMENSIONS, THE DISTANCE TO BE MEASURED SHALL BE THE SHORTEST PATH THAT THE SUPPLY CORD OF AN APPLIANCE CONNECTED TO THE RECEPTACLE WOULD FOLLOW WITHOUT PASSING THROUGH A FLOOR, WALL, CEILING, DOORWAY WITH HINGED OR SLIDING DOOR, WINDOW OPENING, OR OTHER EFFECTIVE PERMANENT BARRIER. (680.34) POOL DECK 1" PVC PIPE TO TRANSFORMER 8" MIN. JUNCTION BOX OR LOWER VOLTAGE TRANSFORMER, TO THE MAX. WATER LEVEL OF THE POOL POOL WALL 1-1/2" PVC PIPE MIN. 16" POOL NICHELESS LIGHT DETAIL NO SCALE 100 W TRANSFORMER JB 1 NEW (4) 10 W 12 V STEP LIGHTS NEW (4) 10 W 12 V STEPS LIGHT NEW 40W 12V LED SPA LIGHT (NICHELESS) NEW (4) 40W 12V LED POOL LIGHT (NICHELESS) AIR RELIEF CARTRIDGE POOL FILTER WITH 320 SQ.FT. OF SURFACE AR 1 'N NOTE: BALL VALVES MAY BE SUBSTITUTED FOR MULTIPORT VALVES TYPE:JANDY POWER CENTER PANEL ENCLOSURE: NEMA 3R SERVICE: - LOCATION: SEE PLAN VOLTAGE: 1W, 120/24o ELECTRICAL PANEL P RATING 100 A. MAINS: MAIN LUG A.I.C.S.: 10000 AIC: 10 K AMPS POLES TOTAL V.A. COND. SIZE WIRE SIZE DESCRIPTION CKT No. CKT No. DESCRIPTION WIRE SIZE COND. SIZE TOTAL V.A. POLES AMPS 20 1 360 1/2" 12 POOL LIGHTS 1 2 POOL BLOWER 2HP 12 1/2" 1000 2 20 20 2 3000 1 /2" 12 POOL PUMP 3HP 5 6 }a� u 12 1 /2" 80 1 20 SPARE 7 8 3360 TILE 4" MIN. FROM WATER LEVEL TO TOP OF LENS INTERIOR POOL FINISH (DIAMOND BRITE) PANEL 'P' TOTAL DEMAND LOAD 100% TOTAL LOAD @ 100%------------- 4 440 W 4 440 W / 240 VOLT =-----------18.5 AMP. @ 100% NOTE: PROVIDE CONTINUOUS SINGLE # 8 COOPER BONDED IN FOUR POINT (360-) AROUND POOL & SPA 1 080 TO POOL EQUIP. NOTE: THIS DESIGN IS AN ALTERNATIVE AND/OR EQUIVALENT TO COMPLIANCE WITH N.E.0 2014 ART. 680.26 (B) & (C). POOL BOND WIRE SHALL BE SECURED TO POOL STEEL WITH APPROVED CLAMP. P SO SQ �0N P00� pip\C, 1�� I' RECIRCULATION PUMP TWO SPEED 3.0 HP WITH 100 GPM AT 60' TD PLUMBING ISOMETRIC N.T.S. O ,. PO ti � LPG H P\R It i 2 HP BLOWER (230 V) POOL DATA: POOL SPA BASIN TOTAL SURFACE AREA (SQ.FT.) 648.0 49.0 72.0 769.0 VOLUME GALLONS 20067 507.5 2423.5 22998 TURNOVER HOURS 2.23 0.05 0.27 2.55 PERIMETER (FEET) 108.0 28.0 1 76.0 212.0 DECK AREA ( SQ.FT) 1498.00 PLUMBING NOTES: 1. ALL POOL EQUIPMENT PIPING SHALL BE SCHEDULE 40, PVC-PW, NON -THREADED, NSF APPROVED SUPPORTED CONTINUOUSLY ON GROUND OR ON MAXIMUM 4'-0" CENTERS WITH CLEVIS HANGERS. 2. ALL SUCTION PIPING SHALL BE 2" DIAMETER AND ALL PRESSURE PIPING 1-1/2" DIAMETER UNLESS OTHERWISE NOTED. 3. POOL WATER DISPOSAL SHALL BE IN ACCORDANCE WITH LOCAL BUILDING DEPARTMENT REQUIREMENTS. 4. ANTI VORTEX MAIN DRAINS SHALL HAVE ITS PLATE SECURELY FASTENED WITH TAMPERPROOF SCREWS. 5. POOL VACUUM SHALL HAVE SPRING LOADED CAP IN ACCORDANCE WITH THE FLORIDA BUILDING CODE. 6. ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE -PLUMBING SECTION 309 AS IT PERTAINS TO BUOYANCY. 7. THE WATER VELOCITY THOUGH ALL SUCTION PIPING SHALL BE LESS THAN 8 FEET PER SECOND. 8. THE WATER VELOCITY THROUGH ALL PRESSURE PIPING SHALL BE LESS THAN 10 FEET PER SECOND. 9. ALL PIPING SHALL BE SUITABLE FOR EXPOSURE TO ULTRA VIOLET RADIATION AND NORMAL OPERATING TEMPERATURES. PROVIDE 4 # 8 COPPER BONDING TAILS (ONE EACH SIDE) CLAMPED TO POOL WALL STEEL FOR DECK BONDING POOL & SPA BOND SCHEMATIC SAME SIZE AS PUMP SUCTION ANTIVOR X MANDRAI COVERS 2" HYDROSTATIC RELIEF TUBE . ONLY ONE REQUIRED MAINDRAIN DETAIL NO SCALE KEfV. DATE : 08/3 0/ 1 L rm s V114%4 � Pccu 305.741.3442 roberto@giapooldesign.cot � � a N 00 M ' 4 !� 0 � ��, �4 u I� W H � Ei En M Qr`1 w z zfg� � M N M N O U � H en UM M .--i w �w Z N Z a 0 cn p� U W a, O o o Q � Ps r-+ � ao 00 o W) oo �4 O IN �. � o N U 1 o O E-+ ri W -- m �al�aU W 2_4 SHEET: 4 OF 4 END TO BE CUT AT\FIEL TRUSS PLACEMENT PLAN SCALE: 3/16=1'-O" 70-1 r-LCV. SECTION ...............A N.T.S. ALL SPACING 24" O.C. UNLESS OTHERWISE NOTED. FOR DRYWALL CONSTRUCTION REFER TO ARCHITECT OR TRUSSES MUST BE NOT BEAR ON WITHOUT STRIPPING, CONTRACTOR ENGINEER FOR COMPLETE TIE ANY INTERIOR WALL OR PARTITION TO PROVIDE 2x4 CONTINUOUS DOWN PROVISIONS FOR TIE UNLESS DESIGNED FOR. LATERAL BRACING AS PER BEAM, WALL AND FOUNDATION ENGINEERING SHEETS. CONDITIONS. R TRUSS LOADING CONDITIONS TOP CHORD LIVE: 30 NUMBERING SYSTEM TOP. CHORD DEAD: 15 DIMENSIONS SHOWN FEET -INCHES -SIXTEENTHS BOTTOM CHORD LIVEN 0 BOTTOM CHORD DEAD: 10 LOAD DURATION: 1.33 END TO BE CUT AT FIEL BEAM LEGEND BEARING ELEV. HGHT. DIFF. 15'-1" (+4'-4") 11'-9" (+1'-0") 10'-9" (+0'-0") BEARING ELEV.=GIVEN FROM FINISHED FLOOR ELEV. DIFF.=DIFFERENCES AMONG BEARING ELEV #1 #3 11P GIRDER tDEIACK�f II 11 II II II II TYPICAL HIP CONNECTION DETAIL REFER TO ENGINEERING PACKAGE FOR DETAILED ATTACHMENT & N.O.A. WIND LOAD CRITERIA DIST. FROM OCEANLINE: N/A EXPOSURE CATEGORY: D BLDG. CATEGORY: I I WIND SPEED: 175 M.P.H. WALL HEIGHT: AS SHOWN DEAD LOAD: 10 P.S.F. BLDG TYPE: ENCLOSED & PARTIALLY ENCLOSED LOAD DURATION: 1.60 ASCE: 7-10 MEAN ROOF HGT.: 1T-0" NOTES: 1. FOR HANGER CONNECTION REFER TO HANGER DETAIL SHEETS ATTACHED, IF APPLICABLE. 2. FOR BRACING ON WEBS AND COMPRESSION REFER TO ENGINEERING SHEETS. 3. FOR HANGER SHOWN CN RCOF LAYOUT, REFER TO HANGER DETAIL SHEETS A TACHEV CM ENGINEERING PACKAGE. 4. FIELD BRACING IS NOT T1'E i—ESPONSIFILITY OF THE TRUSS FABRICATCP. PERSON ERECTING TRUSSES ARE CAUTIONED TO SEEK PROFESSIONAL ADVICE PEG.kRDING ERECTION BRACING WICH IS ALWAYS REQUIRED TO PREVENT TOPPLING AND DOYINOING DURING ERECTION, AND PERMANENT 4RACING WICH MAY BE REQUIRED IN SPECIFIC APP--iGI.6 0NS. TRUSSES SHALL BE ERECTED AND FASTENED IN A STRAIGHT AND PLUMB POSITION. TRUSSES SHALL BE HANDLED WITH REASONABLE CARE DURING ERECTION TO PREVENT DAMAGE. 5. CONTRACTOR OR OWNER MUST SCAB ANY TRUSSES AS REQUIRED AND. SPECIFIED ON ENGINEERING SHEETS. 6. CONTRACTOR OR OWNER IS ADVICED TO SEEK PROFESSIONAL ADVICE BEFORE APPROVING THIS LAYOUT. 7. DO NOT CUT OR ALTER TRUSSES. DECO WILL NOT HONOR BACK CHARGES UNLESS AUTHORIZED BY THIS OFFICE. 8. TRUSSES MAY NOT BE SYMETRICAL. ALWAYS REFER TO ENG. SHEETS WHEN ERECTING TRUSSESI n V Tn 1:ARD1rATC:-0cD TDI IcC 01 A1\ Date: - .S1GN:NERE--: 2'-61/4" Signature: CANT. 15'-1" ELEV. NOTE! 2'-8" 4 RETURN THIS APPROVE DRAWING TO DECO Fim-c-llw-FT51 TRUSS, FABRICATION WILL NOT START UNTIL ry CT 1 3 517 PLAN HAS BEEN RECEIVED SECTION...............B �1 t N.T.S. $ NOTE: CUSTOMER / CONTRACTOR HAS BEEN PROVIDED WITH T.P.I. RECOMMENDATIONS FOR BRACING AND TRUSS ERECTION SE A. RTINEZ, Pit Iv L AND STRUCTURAL ENGINEERS Lpc;r-NSE NO—, PE 0(0509 � ..�t rtt,j s ree ­,nleah,Florida 33 a ,?.17 §CTgLON. construction oc .�merts The contr3dor s respcnsd - i r ofit- ��� o�3rWi E'. j� ens x s, f F rr,BtiJR — --- -- ------ N.T ethc� n r 3�- of h III i er _ REVIBUED: APPROVED AS TED: % (APABLE RRICANE STRAP, WALLS, AND FOUNDATIONS MUST BEITE FRAMING MUST BE APPROVED BY OTHERS.�<JOF WITHSTANDING UPLIFT AS SHOWN ON ENG. ZDWITIONAL INGS & F.B.C. 5.E D LE GER DESIGN AND CONNECTION MUST BE APPROVED BY �ERS.�'� MAHMOUDZOLFAGHARI, P el STRAPS OR OTHER CONNECTIONS ARE REQ'D 6.p O, 01 # 36921 IN ADDITION TO STANDARD CONNECTION. 7 ERECTION SUPERVISION IS REQUIRED. ', i r �� 13901 S.W. 108 AVE. ANY REPAIRS AT THE FIELD MUST BE APPROVED BY A (STING TRUSSES MUST BE CAPABLE OF WITHSTANDING try - MIAMI, FLORIDA � •. �` •� (305)253-2428 REGISTERED ENGINEER. �DITIONAL LOAD DUE TO THE NEW TRUSSES. % •. ,� ��' e LOADIND ON GIRDER TRUSSES MUST BE CHECKED AND VERIFIED BY ARCHITECT OR ENGINEER OF RECORD: €r x ACKNOWLEDGE RECEIPT/ DATE REVISIONS: REV. NUMBER REV. DATE 1 (DL) 09.21.17