RF-15-2783BUILDING
PERMIT APPLICATION
❑BUILDING ❑ ELECTRIC
)res Village
epartment
liami Shores, Florida 33138
Fax: (305) 756-8972
NUMBER: (305) 762-4949
DEC 0 2 z015
FBC 20iq S
Master Permit No. "'QF - I S -2-7 03
❑ ROOFING "& REVISION
Sub Permit No.
❑PLUMBING ❑ MECHANICAL [:]PUBLICWORKS ❑ CHANGE OF
CONTRACTOR
❑ EXTENSION ❑ RENEWAL
❑ CANCELLATION ❑ SHOP
DRAWINGS
JOB ADDRESS:
-Z— f) C s b�
w 0:� "zq—
City:
Miami Shores
County: Miami Dade
Zip: 133\3%
Folio/Parcel#: Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type:�� '�,�sGflood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): `c�t�� �SQE �\v Phone#: ,&6 '? l � 05-
G�
Address
C
City: State: �r 1 Zip: 33i Z%
Tenant/Lessee Name:
Email
Phone#:
CONTRACTOR: Company Name: Cc` \—' Phone#:
Address: 1 DSO k SLZ ZZ'4
City: ��e�c \ o State: zip: 331 q-D
Qualifier Name: Phone#: (0- �34- 3 Li
State Certification or Registration #: Certificate of Competency #:
DESIGNER: Architect/Engineer:
hone#:
Address: City: State: Zip:
Value of Work for this Permit: $ ! / 00eL Square/Linear Footage of Work: `'1� 0
Type of Work: ❑ Addition ❑ Alteration ❑ New %❑
Description of Work: t\% \ 6 \ V\-% `C Q '
Specify color of color thru tile:
❑molition
Submittal Fee $ Permit Fee $� � CCF $CO/CC $
Scanning Fee $ Radon Fee $ �`J DBPR $ �' �� Notary $
Technology Fee $ ' 90 Training/Education Fee $ 0 - 0-10 Double Fee $
Structural Reviews $ Bond $ /
TOTAL FEE NOW DUE $ t
(Revised02/24/2014)
N
"Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature
OWNER or AGENT
The foregoing instrument was acknowledged before me this
Oa day of 20 i.5 by
ho is personally known to
me or who has produced as
identification and who did take an oath.
NOTARY PUBLIC:
Signature
N ACTOR
The foregoing instrument w s acknowledged before me this
�o day o - *ili . 20 4 by
ho is personally known to
me or who has prod ced as
identification and who did take an oath.
NOTARY PUBLIC:
Sign: i/ Sign:=� `
Print: Print: _ �QtN,r P�
e�, 8�.11.., ...._..--
Seal: * * MY COMMISSION t FF 156456 Seal:
MY COMMISSION t FF 156456
EXPIRES: November 30, 2018 01,0"'Ool*
EXPIRES: November 30,2018
Ilmdod ihN N441 NO oftes SONO Thru Budpo! Notry Services
*s*sss*sss*sssss*s*sssssssss*sss sss ssssssssss*sss*ssss*ssss*s*ssssssssssssss*s***sss**sss**s**ssss*ss*s*
APPROVED BY Plans Examiner Zoning
Structural Review Clerk
(Revised02/24/2014)
v
- l S -23�
�r
r►vnoa tsun -- 4)
High -Velocity Hurricane Zone Uniform Permit Appli o
Py
Section A (General Information) _
'* '.laser Permit No. �� ` 1.s'-' .S'3
Process No
Contractor's Name Sr _Ln9l. ?eL7vL� C/� �y,)��,'
Job Address Z 70 6122,11 414111"a d-cam M r /7*— ,,, 'r-/
33770 -
,1
1
1
1
\ 1
1
' ROOF CATEGORY 111
❑ Low Slope ❑ Mechanically Fastened Tile Mortar/A hesi e at s 1
❑ Asphaltic Shingles [] Metal Panel/Shingles F- 1 z
❑ Wood Sh ngl /S a w I S
❑ Prescriptive BUR-RAS 150 1
ROOF TYPE 1 w
❑ New roof ❑ Repair 0 Maintenance Reroofin I cc
i g eco en o
ROOF SYSTEM INFORMATION
.^ Low Slope Roof Area (SFd zV Steep Sloped Roof AREA (SSF; Total
Section _ -= `� 1Z
B (Roof Plan) I =
rs, overflow scuppers and
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppe
overflow ra4 Irt de i _eQ�_ 1'j lions of sections and levels, Dearly identify dimensions of elevated preLLf
ssure zones and locatiGn of parapete,
cis
M
No
No
ME
M1
on
am
0
IN
Mi
WE
M1
M
���BE
���®��®
irilri����CME
�'
0
®�tl•II�L7_.ii��i
�t�®��.�.__
.
1
1
1
1
1
1.
1
1
i
1
1
i
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.37
t i 1 1 1 Copyright to, or licensed by. ICC (ALL RIGHTS RESERVED); accessed by Etiezer 1'alacio on tun 8, 20151032:12 AM pursuant to License
AgreemenL No further reproductions authorized.
Section C
MIAMI-� Miami -Dade County Building Department Electronic Application
High Velocity Hurricane Zone Roofing Permit Application Form
"Delivering Excellence Every Day" Section C page (Low Slope Roof Systems)
Fill in the specific roof assembly components. N a component Is not required, insert not applicable (n/a) in the text box.
ROOF SYSTEM MANUFACTURER: GAF. Top Ply:
Product Approval (NOA): 14-0611.11. System Type: E(2). 1 PLY GAF HEAT -WELD 170 FR.
Top Ply Fastening / Bonding Material:
Wind Uplift Pressures, From RAS 128 or Sealed Calculations: N/A.
(P1) Field: -42.8. psf
(P2) Perimeters: -71.7. psf
(P3) Comers: 108.0. psf
Maximum Design Pressure From NOA: -52.5. psf
Roof Slope: 0.25. " : 12 Roof Mean Height: 10. ft
Parapet Walls: 0 No 0 Yes Parapet wall Height: NIA- ft
Deck Type: --5/8" Support Spacing: Spacing: 24. " o/c
Alternate Deck Type: N/A.
Existing Roof.
BUR.
Fire Barrier.
N/A.
Vapor Barrier.
.N/A
Anchor Sheet:
N/A.
Anchor, Sheet.Fastenorftopding Material:
N/A. • • •
Insulaftyi IIAt Layer fte & Thickness: •
N/A. • ......
insulatipp 935p Layet' ;astt rir / Bondi,*n ial:
.. Af
N/A. • • ... ... •
Insuldipg J'pd Layer SIZE BrThicknesso • • •'
N/A.• • • ••••••
Insulatib To La erf stem; / Bon ui ' • • p P Y A�illaterial:
N/A.4• •
so
Base Sheet(s) & No. of Ply(sj:
1 PLY GAF GLASS BASE #75.
Base Sheet Fastener / Bonding Material:
1 1/4" ring shank & 1 5/8" Tin caps.
Ply Sheet(s) & No. of Ply(s):
1 PLY GAF GLASS BASE #75.
Ply Sheet Fastener / Bonding Material:
1 1/4" ring shank & 1 5/8" Tin caps.
Surfacing: N/A.
SINGLE PLY MEMBRANE:
Single Ply Manufacturer / Type:
N/A.
Single Ply Sheet Width: N/A- " 112 Sheet Width: N/A. "
No. of Single Ply 1/2 sheets: N/A.
Single Ply Membrane Fastening / Bonding Material:
N/A.
0 FASTENER SPACING FOR BASESHEET ATTACHMENT
❑ SINGLE PLY MEMBRANE ATTACHMENT
1. Field: 9- " o/c @ Laps & 2- rows 9- " o/c
2. Perimeter: 6. " o/c @ Laps & 4. rows 6- " o/c
3. Comer. -6 " o/c @ Laps & 4. rows 6. " o/c
NUMBER OF FASTENERS PER INSULATION BOARD:
1. Field: N/A- 2. Perimeter. NA 3. Comer: N/A.
Insulation Fastener Type
N/A
WOOD NAILER TYPE AND SIZE:
N/A.
Wood Nailer Fastener Type and Spacing:
N/A.
EDGE & COPING METAL SIZES:
Edge Metal Material: —Galvanized Metal —
Edge Size: --3" face 26 ga —
Hook Strip Size: --METAL EDGE HOOK STRIP N/A —
Edge Metal Attachment:
1 1/4" RING SHANK NAIL 4" O.C..
Coping Material: —PARAPET COPING METAL N/A —
Coping Size: —COPING METAL SIZE N/A —
Hook Strip Size: 17COPING METAL HOOK STRIP N/A --
Parapet Coping Metal Attachment:
N/A.
Edge Nailable Deck
M® Miami -Dade County Building Department Electronic Application
High Velocity Hurricane Zone Roofing Permit Application Form
"Delivering Excellence Every Day"
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Terminations/Stripping/Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc.
Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material
Thickness, Fastener Type, Fastener Spacing
Or: Submit Manufacturers Details that Comply with RAS-111 and Chapter 16.
Tula Ply
Interplies
Base Sheet
1 PLY SMOOTH HEAT -WELD 9"
STRIP OVER METAL
WOOD DECK
• •
ood
•
•
'
• } 0040,00•
R
.
....•.
V
�•
. ••
4
......
. .
.
.
0 0
--�- Drip Metal
Roof Mean Height: i ® ft.
Drip Metal:
3"X3" GALVANIZED. 2 9 6—cl e.•
Surfacing:
N/A.
Top Ply:
1 PLY HEAT -WELD 170 FR.
Interplies:
1 PLY GAF GLASS BASE #75.
Base Sheet:
1 PLY GAF GLASS BASE #75.
Deck Type:
WOOD.
COUNTY
MIAMI-DARE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION R) Miami, Florida 5
T (786)315-2590 F (786) 3131525.25-99
99
NOTICE OF ACCEPTANCE (NOA) www miamidade eov/economv
GAF
1361 Alps Road
Wayne, NJ 07470
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their
jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County
Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION:: GAF Ruberoid®Modified Bitumen Roof System for Wood Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
• • • • followijig jstatgment: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
• itENEWALof this'NOA$hall be considered after a renewal application has been filed and there has been no
..... 000000
• Change in the-applioeble building code negatively affecting the performance of this product.
•••••
•�•••TERMIDIATION of (hij JNOA will occur after the expiration date or if there has been a revision or change in
•'; • the materials:use, and[ot:uianufacture of the product or process. Misuse of this NOA as an endorsement of any
• • " produggo for• ales advetrtisin or another poses shall automatically terminate
• • • • +with anj %tttion of thi -N?),A shall be cause fo termination and removal of NOAthis NOA. Failure to comply
• • • •' •ADVWfIJEMEA 1::, The NOA number preceded by the words Miami -Dade County, Florida, and followed
.•
by the 8xpit; tion 4tei fmv be displayed in advertising literature. If any portion of the NOA is displayed, then
it shale& d&e in it9 entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 13-0424.14 and consists of pages 1 through 29.
The -submitted documentation was reviewed by Jorge L. Acebo.
MIAMI-DADE COUNTY
NOA No.: 14-0611.01
Expiration Date: 11/06/15
Approval Date: 11/66/14
Page 1 of 29
ROOFING SYSTEM APPROVAL
Category:
Roofing
Sub— Category.
Modified Bitumen
Material:
APP/SBS
Deck Type:
Wood
Maximum Design Pressure:
-75 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product
Dimensions__
Test
Specification
Product
Description
Matrix"" 102 SBS
5 gallons
ASTM D3019
Fiber reinforced rubberized cold -applied
Membrane Adhesive
adhesive for modified bitumen roof
GAFGLAS #75
39.37"
ASTM D4601
systems.
Type H asphalt impregnated and coated
Base Sheet
(1 meter) Wide
glass mat base sheet.
GAFGLAS® #80 Ultima"m
39.37"
ASTM D4601
Type 11 asphalt impregnated and coated,
Base Sheet
(1 meter) Wide
fiberglass base sheet.
GAFGLAS® F1exPlyTM 6
39.37"
ASTM D2178
Type VI asphalt impregnated glass felt
GAFGLAS® Ply 4
(1 meter) Wide
39.37"
ASTM D2178
with asphalt coating.
Type IV asphalt impregnated glass felt
GAFGLAS® Mineral
(1 meter) Wide
39.37"
ASTM D3909
with asphalt coating.
Asphalt coated, glass fiber mat cap sheet
Surfaced Cap Sheet
GAFGLAS' EnergyCap"
(1 meter) Wide
39.37"
surfaced with mineral granules.
ASTM D3909
Asphalt coated, glass fiber mat cap sheet
BUR Mineral Surface Cap
(1 meter) Wide
surfaced with mineral granules with
Sheet
GAFGLAS® Stratavent®
39.37"
ASTM D4897
factory applied EnergyCoteTM
Fiberglass base sheet coated on both sides
V .0ato* Perforated
.enti�gj3�se Sheet
(1 meter) Wide
with asphalt. Surfaced on the bottom side
...... ..
with mineral granules embedded in
'
• • • •
asphaltic coating with factory
.' GAF&S® Strativarlt®:
• Eliminator- Perforated-
39.37"
ASTM D4897
perforations.
A nailable, fiberglass base sheet coated on
•
• Nailable Whting its; • •
(1 meter) Wide
both sides with asphalt. Surfaced on the
Sheet • • • •
bottom side with mineral granules
• • 6 0
:' •. •: Ruberoiv(?SBS `0
39.37"
ASTM D6164
embedded in asphaltic coating.
Non -woven polyester mat coated with
•..... Heat-y eld7. Smooth"'
(1 meter) Wide
polymer -modified asphalt and smooth
.' . •• . ..
• • .... RuberoieSBS '.. :
HeatVeld•
39.37"
ASTM D6164
surfaced.
Non -woven polyester mat coated with
Granule
(1 meter) Wide
polymer -modified asphalt and surfaced
RoofMatchTM
107 sq. ft.
ASTM D6164
with mineral granules.
Non -woven polyester mat coated with
SBS Modified Granular
(9.9 m2)
SBS polymer -modified asphalt and
®
Ruberoid SBS
39.37"
ASTM D6164
surfaced with colored mineral granules.
Non -woven polyester mat coated with fire
Heat -Weld"` 170 FR
(1 meter) Wide
retardant polymer -modified asphalt and
surfaced with mineral granules.
NOA No.: 14-0611.01
MAMMADECOUNTY
FTI O
Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 2 of 29
Product
Dimensions
Test
Specification
Product
Description
Ruberoid® SBS
Heat-Weid7 Plus
39.37"
ASTM D6164
Non -woven polyester mat coated with
(1 meter) Wide
polymer -modified asphalt and surfaced
®
Ruberoid SBS
39.37"
ASTM D6164
with mineral granules.
Non -woven polyester mat coated with fire
Heat -Weld Plus FR
(1 meter) Wide
retardant polymer -modified asphalt and
Ruberoid® EnergyCap"
39.37"
ASTM D6164
surfaced with mineral granules.
Non -woven polyester mat coated with fire
SBS Heat-WeIC Plus FR
(1 meter) Wide
retardant polymer -modified asphalt and
surfaced with mineral granules and with
Ruberoid® SBS
39.37"
ASTM D6163
factory applied EnergyCote.
Non -woven polyester mat coated with
Heat -Weir 25
(1 meter) Wide
polymer -modified asphalt and smooth
Ruberoid® Mop Granule
39.37"
ASTM D6164
surfaced.
Non -woven polyester mat coated with
(1 meter) Wide
polymer -modified asphalt and surfaced
Ruberoid® Mop Smooth
39.37"
ASTM D6164
with mineral granules.
Non -woven polyester mat coated with
(1 meter) Wide
polymer -modified asphalt and smooth
Ruberoid® Mop Plus
39.37"
ASTM D6164
surfaced.
Non -woven polyester mat coated with
(1 meter) Wide
polymer -modified asphalt and surfaced
Ruberoid® Mop 170FR
39.37"
ASTM D6164
with mineral granules.
Non -woven polyester mat coated with fire
(1 meter) Wide
retardant polymer modified asphalt and
Ruberoid® Mop FR
39.37"
ASTM D6164
surfaced with mineral granules.
Non -woven polyester mat coated with fire
(1 meter) Wide
retardant polymer -modified asphalt and
Rubenoid®Xbrch Smooth
39.37"
ASTM D6222
surfaced with mineral granules.
Non -woven polyester mat coated with
:....: • • • ..
(1 meter) Wide
APP modified asphalt and smooth
...... • • • �•
• Ruberoid 'Porch r ule
39.37"
ASTM D6222
surfaced.
Non -woven polyester mat coated with
' " • • • •
(1 meter) Wide
APP modified asphalt and
. • •; • • '.: w� •
..... Ruber9jq'.Energy ap•
39.37"
surfaced with mineral granules
• . Torch.GwAle FR• •
(1 meter) Wide
ASTM D6222
APP modified cap membrane with a torch
• : : • :
grade bottom surface and a mineral
granular top surface coated with factory
•o. *go***
• goo.
• • • • RubevoidI EnergyC ap .
39.37"
ASTM D6222
applied EnergyCote7
APP modified cap membrane with a torch
Tore"Cv4ule Plus FR •
(1 meter) Wide
grade bottom surface and a mineral
granular top surface coated with factory
RoofMatchTM
107 sq. ft.
ASTM D6222
applied EnergyCote".
Non -woven polyester mat coated with
APP Modified Granular
(9.9 m2)
APP polymer -modified asphalt and
®
Ruberoid Torch FR
1 meter
ASTM D6222
surfaced with colored mineral granules.
Non -woven polyester mat, coated with fire
(39.37") Wide
retardant asphalt modified bitumen
membrane with granule surface.
NOA No.: 14-0611.01
MIAMI•DADE COUNTY
Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 3 of 29
Product
Dimensions
Test
Specification
Product
Description
Ruberoid® 20
1 meter
ASTM D6163
SBS modified asphalt base sheet reinforce
Ruberoid® 30
(39.37") Wide
with a glass fiber mat.
1 meter
ASTM D6163
Non -woven fiberglass mat coated with
(39.37") Wide
polymer modified asphalt and surfaced
Ruberoid® 30 FR
1 meter
ASTM D6163
with mineral granules.
Non -woven fiberglass mat coated with fire
(39.37") Wide
retardant, polymer -modified asphalt and
Ruberoid® EnergyCap- 30
1 meter
ASTM D6163
surfaced with mineral granules.
Non -woven fiberglass mat coated with fire
FR SBS Membrane
(39.37") Wide
retardant, polymer -modified asphalt and
surfaced with mineral granules and with
Ruberoid® Dual FR
39.37" (1 meter)
ASTM D6162
factory applied EnergyCote.
Non -woven polyester and fiberglass mat
Wide
coated with file retardant, polymer -
modified asphalt and surfaced with
Topcoat® Elastomeric
1, 5 or 55 gallons
ASTM D6083
mineral granules.
An acrylic, water based elastomeric
Roofing Membrane
membrane system designed to protect
Topcoat® MB Plus
5 or 55 gallons
Proprietary
various types of roofing surfaces.
Water based, low VOC primer used to
Topcoat ®
block asphalt bleed -through.
5 gallons
ASTM D6083
Solvent based sprayable thermoplastic
Surface Seal SB
rubber sealant designed to protect and
restore aged roof surfaces and to increase
FireOut- Fire Barrier
5, 55 gallons
Proprietary
a roofs reflectivity.
Low VOC, water -based fire barrier
Coating
coating.
VersaShield®
42" x 100' rolls
ASTM D226
Non -Asphaltic, fire resistant fiberglass -
Fire -Resistant Roof Deck
•
based underlayment.
• ;
Protetken •
......
....
NOA No.: 14-0611.01
Mu►MFDADE COUNTY Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 4 of 29
APPROVED INSULATIONS:
Product Name
EnergyGuard'
Polyiso Insulation
EnergyGuard7
RA Polyiso Insulation
EnergyGuarC
RN Polyiso Insulation
EnergyGuarC
Perlite Recover Board
EnergyGuard'
Perlite Roof Insulation
EnergyGuarC
RA Composite Polyiso
Insulation
Structodeko High Density Fiber Board
Securock® Gypsum -Fiber Roof Board
Table 2
Product Description
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Perlite recover board
Perlite roof board
Polyisocyanurate/wood fiberboard
or perlite composite
High density wood fiber
Gypsum board
Manufacturer
(With Current NOA)
GAF
GAF
GAF
GAF
GAF
GAF
Blue Ridge FiberBoard, Inc.
United States Gypsum Corp.
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
1. Drill-TecTM #12 Fastener Carbon steel fastener used Various GAF
in steel or wood decks.
2.
Drill-TecTM # 14 Fastener
Carbon steel fastener used
Various
GAF
in steel, wood or concrete
decks.
3.
Drill-TecTM XHD Fastener
Carbon steel extra heavy
Various
GAF
duty fastener used in steel
decks.
•
.•0
• *Drill-TecTM AccuTrac® Flat
AZ -SS aluminized steel
3" x 3"
GAF
• • • •
Plate
plate for use with Drill-
• • • • • •
......
TecTM # 12 Fastener, Drill-
• '
•
••••••
TecTM # 14 Fastener and
• •""
•5.
Drill-Tec"" #15 Fastener.
. ":'•
�6
0 Drill-%(J"g.ASAP 3S
Drill-Tec"fm #12 fastener
Various
GAF
••.••
•••• ••••
TM
with Drill-Tec 3"
• • • • •
• • " • • • •
Standard Steel Plate.
.. • • • •
6�
. .
Drill'T:C�''AccuTrac®
Galvalume Steel plate for
3" x 3"
GAF
•.
Reces's9ap'late
use with Drill-Tec"m
• • • • • •0
fasteners.
Drill-TecT�p3" Steel Plate
Round galvalume steel
3"
GAF
stress plate for use with
Drill-Tec"m fasteners.
8.
Drill-Tec"° 3" Standard
Round galvalume plated
3"
GAF
Steel Plate
steel stress plate with
reinforced ribs for use with
Drill-TecTM fasteners.
NOA No.: 14-0611.01
MIAMI•DADE COUNTY Expiration Date: 11/06/15
' 1 Approval Date: 11/06/14
Page 5 of 29
EVIDENCE SUBMITTED:
Test Agency
Test Identifier.
Description
Date
Factory Mutual Research Corp.
3029832
FMRC 4470
05/11/07
3010215
FMRC 4470
03/01/01
3001276
FMRC 4470
01/28/99
1B9A8.AM
FMRC 4470
09/04/97
3D4Q2.AM
FMRC 4470
04/30/97
OD1A8.AM
FMRC 4470
04/01/98
Underwriters Laboratories
R1306
UL 790
07/22/13
Trinity Engineering
4483.04 97-1
TAS 114
06/06/97
PRI Asphalt Technologies, Inc.
GAF-020-02-01
ASTM D249
02/01/02
ASTM D4977
GAF 306-02-01
ASTM E96
07/07/11
GAF 315-02-01
ASTM D2178
8/23/11
GAF 314-02-01
ASTM D2178
8/23/11
IRT-ARCON Inc.
02-005
TAS 114
03/01/02
02-014
TAS 114
04/08/02
01-039
TAS 114
03/01/02
Trinity I ERD
G6850.08.08
ASTM D6164
08/29/08
G6850.08.08
ASTM D6163
08/01/08
G6850.10.08
ASTM D6222
10/06/08
G6850.11.08
ASTM D6222
11/05/08
G40620.07.12-2
ASTM D6222
07/17/12
• �•
G34140.04.11-2
ASTM D6163
04/25/11
•
G31360.03.10
ASTM D6164
03/31/10
G34140.04.11-4
ASTM D4601
04/25/11
' • • • • •
• • • • •
G34140.04.11-5
ASTM D4897
04/25/11
'
G33470.01.11
ASTM D6164
01/13/11
• • • •'
• • • • ..
•' •'•
G6850.08.07-1
ASTM D3909
08/ 13/07
•�•�••
�••�••
G30250.02.10-3-R1
ASTMD3909
11/26/12
• • • • •
•
PI 1 Mistruction ft-t6ologies LLC.
ASTM D2178
GAF-314-02-01
08/23/11
000000
ASTM D2178
GAF-315-02-01
08/23/ 11
• •
• • • •
ASTM D6083
GAF-245-02-01
06/ 10/ 10
' • • • • •
ASTM D6083
GAF-084-02-01
07/08/05
• • •
ASTM D6083
GAF-245-02-01
06/ 10/ 10
ASTM D6083
GAF-084-02-01
07/08/05
Momentum Technologies, Inc.
ASTM D6162
AX04C9A
06/05/09
NOA No.: 14-0611.01
MIAMI•DADE COU� Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 6 of 29
Membrane Type: APP/SBS Heat Weld
Deck Type 1: Wood, Non -insulated
Deck Description: . 19/32" or greater plywood or wood plank decks
System Type E(2): Base sheet mechanically fastened.
All General and System Limitations shall apply.
Fire Barrier: FireOut'm Fire Barrier Coating, VersaShieldo Fire -Resistant Roof Deck
(optional) Protection or Securocke Gypsum -Fiber Roof Board.
Base sheet: GAFGLAS® #80 Ultima' Base Sheet, GAFGLAS® Stratavents Eliminator'
Nailable Venting Base Sheet, Ruberoid® Mop Smooth, Ruberoid® 20, Ruberoid®
SBS Heat -Weld" Smooth or Ruberoid® SBS Heat -Weld' 25 mechanically
fastened to deck as described below;
Fastening GAFGLAS® Ply 4, GAFGLAS® F1exPly"° 6, GAFGLAS® #75 Base Sheet or any
Options: of above base sheets attached to deck with approved annular ring shank nails and
tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12"
o.c. in the field.
(Maximum Design Pressure —45 psf. See General Limitation #7)
GAFGLAS® Ply 4, GAFGLAS FlexPly'" 6, GAFGLAS® #75 Base Sheet or any
of above base sheets attached to deck with Drill-Tec"' # 12 Fastener, Drill-Tec'.'
#14 Fastener or Drill-Tec"' XHD Fastener and Drill-Tec"' 3" Steel Plate, Drill-
Tec"' AccuTraco Flat Plate or Drill-Tec"' AccuTraco Recessed Plate installed
12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally
spaced approximately 12" o.c. in the field of the sheet.
• • • • • • .(Maximum Design Pressure —45 psf. See General Limitation #7)
;GAFGLAS® F1exPly" 6, GAFGLAS® #75 Base Sheet or any of above base
• ' • •'•*sheets attached to deck with approved annular ring shank nails and tin caps at a
...... .. . .. ..
• fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
..... . .. ...... .
• field.
..... .... ...
• *(Maximum Design Pressure —52.5 psf. See General Limitation #7)
• """GAFGLAS® #80 Ultima"' Base Sheets, Ruberoide20, Ruberoid®Mop Smooth,
...... .. . ......
• • • • • • base sheet attached to deck with approved annular ring shank nails and tin caps at
.:.... • • • ;a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
• (Maximum Design Pressure —60 psf. See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with
Drill-Tec#12 Fastener, Drill-Tec"' #14 Fastener or Drill-Tec"' XHD Fastener
and Drill-Tec"' 3" Steel Plate, Drill-Tec"' AccuTrac® Flat Plate or Drill-Tec'rm
AccuTrae Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 9" o.c. in the field of the
sheet.
(Maximum Design Pressure —60 psf. See General Limitation #7)
NOA No.: 14-0611.01
MIAMI•DADECcIUNTY Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 27 of 29
Fastening Any of above base sheets attached to deck approved annular ring shank nails and
Options: 3" inverted Drill -Teem insulation plates at a fastener spacing of 9" o.c. at the 4"
(Continued) lap staggered in two rows 9" in the field.
(Maximum Design Pressure —60 psf. See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with
Drill-Tec'' #12 Fastener, Drill-Tec"m #14 Fastener or Drill -Teem XHD Fastener
and Drill -Teem 3" Steel Plate, Drill-Tec." AccuTrace Flat Plate or Drill-TecT"
AccuTrace Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 9" o.c. in the field of the
sheet.
(Maximum Design Pressure —75 psf. See General Limitation #7)
Ply Sheet: (Optional except over Ruberoid® Mop Smooth, Ruberoid® 20, Ruberoid® SBS
Heat -Weld'' Smooth or Ruberoid® SBS Heat -Weld"' 25) One or more plies
GAFGLAS® Ply 4 or GAFGLAS® FlexPlyj' 6 sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or
Ruberoie Torch Smooth torch applied according to manufacturer's application
instructions.
Membrane: One ply of Ruberoid® Torch Smooth, Ruberoid® Torch Granule, RoofMatch'
APP Modified Granular, Ruberoid® EnergyCap'"' Torch Granule FR, Ruberoid®
EnergyCap"' Torch Plus FR, or Ruberoid® Torch FR torch applied according to
manufacturer's application instructions.
Or
One or more plies of Ruberoid® SBS Heat -Weld° Plus, Ruberoid® SBS Heat-
Weldm Plus FR, Ruberoid® SBS Heat -Weld"' 170 FR, Ruberoid® EnergyCap'
SBS Heat -Welt Plus FR, Ruberoid® SBS Heat -Weld" Granule, Ruberoid® SBS
• Heat -Weld' Smooth and Ruberoid® SBS Heat -Weld'" 25 applied according to
• jnanufacturer's application instructions.
...... . . . .
Surfacing: ; �; , •optional on granular surfaced membranes; required for smooth membranes.
• • • • • • • • .. .Chosen components must be applied according to manufacturer's application
• • • • .... • • • • •. •instructions. All coatings must be listed within a current NOA.
..... ....
•• '],.., Grad�l•gr,Aag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved
•0 asphalt jt 60 lbs./sq.
•; • • • • a e � : GAVOLASO Mineral Surfaced Cap Sheet or GAFGLASOEnergyCap'm BUR Mineral
• • • • Surface dCap Sheet adhered in a full mopping of approved asphalt applied within the EVT
""0 0 0 a 0 range and st a rate of 20-40 lbs./sq.
3. Topcoat® Elastomeric Roofing Membrane, Topcoat® MB Plus (to be used as a primer with
Topcoat® Elastomeric Roofing Membrane) or Topcoat® Surface Seal SB applied at 1 to 1.5
gal./sq.
Maximum Design
Pressure: See Fastening Options
NOA No.: 14-0611.01
MIAMI•DADE COUNTY Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 28 of 29
WOOD DECK SYSTEM LIMITATIONS:
1 A slip sheet is required with GAFGLASa' Ply 4 and GAFGLAS® FlexPly T' 6 when used as a
mechanically fastened base or anchor sheet.
2. Minimum '/4" DensDecO Roof Board or ''/2" Type X gypsum board is acceptable to be installed
directly over the wood deck.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall
be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum
design pressure of -45 psL
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
• as field-tested, are below 275 lbf. insulation attachment shall not be acceptable.
• • • • 6. ; Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
• on a minimdefastener resistance value in conjunction with the maximum design value listed within
• • • • s sopoes"ific system. •Should the fastener resistance be less than that required, as determined by the
• • • • • Building O r O, x revised fastener spacing, prepared, signed and sealed by a Florida Registered
. E%giQeer, NtNect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
• • • • %half Utilize'thMthdrawal resistance value taken from Testing Application Standards TAS 105 and
• •' : t l iation9 fr d-ompliance with Roofing Application Standard RAS 117.
• • • • • • 7. Perimeter ap0.*cpj6Ver areas shall comply with the enhanced uplift pressure requirements of these
•..... xeas. Fastgiaer.dejisities shall be increased for both insulation and base sheet as calculated in
. • •. • comp�liancewitk.Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
• by : Florida tegisi6ed Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not
be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 14-0611.01
MiartH•naDE couNTY Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 29 of 29
TGFU.R1306 - Roofing Systems
Page 16 of 56
Insulation (Optional): — Polylsocyanurate, wood fiber, perlite, glass fiber, any thickness, hot mopped or mechanically fastened.
Base Sheet: — One or more plies Type G2 "GAFGLAS@ #75 Base Sheet", or "Tri-Ply® #75 Base Sheet", mechanically fastened.
Ply Sheet : — One or more plies "Ruberoid@ 20" or "Ruberoid@ 20 HT" or "Ruberoid@ Dual Smooth" hot mopped in place.
Membrane: — One pIy' "Ruberoid® SBS Heat Weld Plus FR" or "Ruberoid@ SBS Heat Weld 170 FR" heat welded In place.
56. Deck. C-15/32
Incline: 1/2
Base Sheet: — Two or more plies Type G2 "GAFGLAS@ #75 Base Sheet" or'Tri-Ply® #75 Base Sheet" mechanically fastened
Membrane: — One ply "Ruberoid@ SBS Heat Weld Pius FR" or"Ruberold@ SBS Heat Weld 170 FR" heat welded in place.
57. Deck: NC
Incline: 1/2
•s� c i
V.sb
Base Sheet: — "Ruberoid@ Mop Smooth" or "Ruberoidp Mop Smooth 1.5" or"Ruberoidp? Mop Smooth Plus" or "Ruberoid@ Dual Smooth"
hot mopped or "Ruberofd@ SBS Heat Weld Smooth" heat welded.
Membrane: — "Ruberoidp SBS Heat Weld Plus FR" or "Ruberoid@ SBS Heat Weld 170 FR" heat welded.
58. Deck: NC
Incline: 1/2
Insulation (Optional): — Polyisocyanurate, uniform thickness of tapered minimum 1-1/2-in., mechanically fastened or adhered with 'LRF
Adhesive M" or OMG Inc. "Olybond Fastening System" applied as a nominal 3/4-In. bead or "GAF 2-Part Roofing Adhesive" applied as a
nominal 21/i-in. bead with a maximum on -center spacing of 12-in, or any
Installation Instructions. UL Classified insulation adhesive applied per the manufacturer's
'
Barrier Board: — Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck Prime@ Roofboard" or
"SECUROCK@ Glass-Mat"DensDeck DuraGuard— Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK@ Roof Board" (Type FRX-G) or
with OMG Inc. "Olybond Fas
Base Sheet: —One ply Liberty SBS Self -Adhering oof Board" (Type )Base Ply Sheet" tf or ast°Ruberoid@ Sned or SA Base/Ply Sheet" self-adheredtening System".
Ply Sheet: — One ply "Rubberoid SBS Heat Weld 25" heat fused
Membrane: — One ply "Ruberoid@ SBS Heat Weld Plus FR" or "Ruberoid@ SBS Heat WPi i 17n FD"" k A.—
59. Deck: C-15/32 Incline: 1/2 _-•--_.--"__.
Insulation (Optional): (Optional): — Polyisocyanurate, uniform thickness of tapered minimum 11/2-in. mechanically fastened or adhered with OMG
Inc. "Olybond Fastening System"
"DensDeck Prime@ Roo
Barrier Board: — Minimum 1/4-in. thick Geogla-Pacific Gypsum LLC "DensDeck@ Roofboard" Roofboard" or
"DensDeck DutaGuardTM° Roofboard" or minimum 4-In. thick United States Gypsum Corp. "SECUROCK@ Roof Board" (Type FRX-G) or
or
"SECUROCK@ Glass -Mat Roof Board" (Type SGMRX) with all butt joints in the barrier board staggered a minimum of 6-in. from plywood
deck buttjoin"mechanically fastened or adhered with OMG Inc. "Olybond Fastening System"
Base Sheets — One ply "Liberty SBS Self -Adhering Base/Ply Sheet" or "Ruberoid@ SA Base/Ply Sheet" self -adhered
• • • •,ly Sheet! •- Mhe ply "PDbV?A4 SBS Heat Weld 25" heat fused
• Nembrane: oee ply "Rrberoid@ SBS Heat Weld Plus FR" or "Ruberoid@ SBS Heat Weld 170 FR" heat fused
••••••
•
60.eDeck: C-15/329 i • i • • i Incline: 1/2
•
• • • •19arrier BAard101A Minimett - Nf! thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck Prime@ Roofboard" or
• • • e * pensDecl*gtw4Guard— Rwikasrd" or minimum 1/4-In. thick United States Gypsum Corp. "SECUROCK@; Roof Board" (Type FRX-G) or
• "1ECUROejCQ Glass -Mat R�CQV rd" (Type SGMRX) with all butt joints in the barrier -board staggered a minimum of 6-in. from plywood
• • • • ck butt oin mechanica y astened
• ftse Sheet! — One ply "MrMMS #75 Base" or "Tri-Ply@ #75 Base Sheet" mechanically fastened
• • • • oNembrano*-- OQe ply "BlAlieNOW Torch FR" heat welded
fiJCl k: NC • • • incline: 2
••••••
•
Insulation (Optional): — One or more layers perlite, wood fiber, glass fiber, polyisocyanurate, periite/polyisocyanur'ate composite, wood
fiber/polyisocyanurate composite, any thickness mechanically fastened or adhered with "LRF Adhesive M" or OMG Inc. "Olybond Fastening
System" applied as a nominal 3/4-rn. bead or "GAF 2-Part Roofing Adhesive" applied as a nominal 21h-in. bead with a maximum on -center
spacing of 12-in. or any UL Classified Insulation adhesive applied per the manufacturers Installation Instructions.
Base Sheet: — One ply Type G2 "GAFGLAS@ #75 Base Sheet"or "Tri-Ply® #75 Base Sheet", or "GAFGLAS@ Ply 6" fully adhered with hot
roofing asphalt.
Ply Sheet (Optional): — Three or more plies Type G1 "GAFGLAS@ Ply 4" or 'Tri-Ply@ Ply 4", or "GAFGLAS@ Ply 6" fully adhered with hot
roofing asphalt.
Membrane (Optional): — "Ruberoid@ Mop Plus Granule" or "Ruberoid@ Mop Granule" or "Ruberoid@ 30" or "Ruberoid@ 30 FR" or
"Ruberoid@ 30 FR HT" or "Ruberoid@ EnergyCapTM SBS 30 FR" or "Ruberoid@ Mop Smooth" or "Ruberoid@ Mop Smooth 1.5" or
"Ruberoid@ Mop Smooth Plus" or "Ruberoid@ Mop 170" or "Ruberoid@ Mop 170 FR" or "Ruberoid@ Dual Smooth" fully adhered with hot
roofing asphalt or "Ruberoid@ SBS Heat Weld 170 FR" or "Ruberoid@ SBS Heat Weld Plus FR" or "Ruberoidp SBS Heat Weld Smooth",
heat fused
Surfacing: — Roofing gravel applied at a rate of 400-lbs./100-ft.2 embedded into a Flood coat of hot roofing asphalt or No. 10 White
Aggregate applied at a rate of 200-lbs./100-ft.2 embedded into "TOPCOAT@ Fire shield MB" applied at a rate of 2-1/2 - 3-gal./100-ft.2.
Top Surfacing: — "TOPCOAT@ EnergyCoteTM Elastomeric Coating", applied at a rate of 0.5 - 1.0-gal./100-ft.2.
62. Deck: C-15/32
Incline: 2
http://database.ul.com/cgi-bWXYV/template/LISEXT/1 FRAME/sho�vpage.html?name=T... 2/26/2014