Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-17-723
F�ORW Project Address Miami Shores Village 10050 N.E. 2nd Avenue NW Miami Shores, FL 33138-0000 Phone: (305)795-2204 Parcel Number Permit NO. RC-3-17-723 ■ Permit Type: Residential Construction ' Work Classification: Alteration Permit Status: APPROVE) Issue Date: 4117/201-1 1 Expiration: 10/14/2017 Applicant 43 NW 110 Street 1121360030610 Miami Shores, FL 33168-4318 Block: Lot: INTER MALL INC INTER MALL INC Address 8260 SW 2 Street MIAMI FL 33144- 8260 SW 2 Street MIAMI FL 33144- Contractor(s) Phone Cell Phone TOP CRAFTS INC (305)258-1439 In Review Date Approved:: In Review Date Denied: Type of Construction: INTERIOR REMODELING & CARPO Occupancy: Single Family Stories: Exterior: Front Setback: Rear Setback: Left Setback: Right Setback: Bedrooms: Bathrooms: Plans Submitted: Yes Certificate Status: Certificate Date: Additional Info: Bond Return : Classification: Residential Fees Due Amount Bond Type - Owners Bond $500.00 CCF $19.20 CO/CC Fee $50.00 DBPR Fee $14.40 DCA Fee $14.40 Education Surcharge $6.40 Permit Fee $960.00 Plan Review Fee (Engineer) $120.00 Plan Review Fee (Engineer) $120.00 Scanning Fee $27.00 Technology Fee $25.60 Total: $1,857.00 Phone Cell (786)231-7789 Valuation: $ 32,000.00 Total Sq Feet: 800 Pay Date Pay Type Amt Paid Amt Due Invoice # RC-3-17-63346 03/16/2017 Check #: 1301 $ 320.00 $ 1,537.00 04/17/2017 Credit Card $ 1,537.00 $ 0.00 Bond #: 3377 Available Inspections: Inspection Type: Final PE Certification Window Door Attachment Framing Insulation Drywall Screw Window and Door Buck Fill Cells Columns Review Electrical Review Planning Review Structural Review Building Review Plumbing Review Mechanical In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto Vol in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this perNit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELEC ICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS A F I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction z utherm�, I authorize the above -named contractor to do the work stated. April 17, 2017 Autfid'FFze,001bg Nartment ture:Owner / Applicant / Contractor / Agent Building De Copy April 17, 2017 BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RE4 c.FT MA 6 2017 BY' �� Vl FBC 20 Master Permit No. i lC I ` Z,3 Sub Permit No. F711BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION [:]RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS [:]CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOBADDRESS: Y2 �jUj 1/O S"t' City: Miami Shores County: Miami Dade zip: 33165 Folio/Parcel#: 11- 21,36 -00 3 - 0 6 /0 Is the Building Historically Designated: Yes NO X Occupancy Type: C_s Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): -Twk p '6 &_ jz 1 VI C . Phone#:�g�- Z31 �q Address: 9,2 4 0 S U3 2 S`- City: 0'7k wm'l State: - C, zip: If Y Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: 0012 e-S�-'Y S 1hC. Phone#: Address: /T f0 19 3u% 99 St City: A )omi State: f L zip: . 3/9'6 Qualifier Name: ,(-L:,J-.$ d ,QOcty'i4oe7k Phone#: State Certification or Registration #: C G C 1 S 0 q,61 Certificate of Competency #: DESIGNER: Architect/Engineer:., 1-0. YQ C Phone#: 0 rJ- JrS I' 9� ZI Address: l ��✓' �/ W <S 07 %jL City: m / Q K4 % State:. FC I Zip: t5 Value of Work for this Pe-rrriit: $ . 3 Z, 0 d 0 Square/Linear Footage of Work: S•e. Type:ofWork: �E.;J.,Additj�iii ,�� Alteration ❑ New M Repair/Replace ❑ Demolition - #,- r - w +e. .u.. Description of Work: SY i• P_V i od' -<QyVXo d e 0 iy1 j 'C' Caory)A c6v".r QV' Si av� Specify color of color thru tile: Submittal Fee $ 2 Permit Fee $ (90' CCF $ - /' 2-0 CO/CC $ 5a�"{0:�, Scanning Fee $ 2_� " G7 Radon Fee $ �'V DBPR $ Notary $ J� Technology Fee $ " Training/Education Fee $ Double Fee $ 1-0 Structural Reviews $ IZD`CC� \ Bond $ CA3 J TOTAL FEE NOW DUE $ _ I / ^^\\ ` • ) (Revised02/24/2014) ✓?� ( C��] Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip , _ Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. ` "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR -,NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated valut exce ding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law LiNchurt will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commen me t must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the ce of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature OWNER or AGENT The foregoing instrument was day OOXI me or who h s od identification a w ```1 Y P, NOTARY PUB 9, OF FL 1 Sign: In 14 Print: Seal: APPROVED BY (Revised02/24/2014) before me this 20 1- by who is personally known to MAY A DE LOS ANGELES MARTINEZ i9 oaf Iry public - State of Florida My Comm. Expires Sep 16, 2017 Commission # FF 054717 CONTRACTOR The foregoing instrument was a nt day of I ' ,a--1( P4)A- me or who has produ O identification and wh k. N NOTARY PUBLIC: ; Sign: Print: \In A a.U'n Q Seal: edged before me this / 20 Jr 7 by is personally known to AARTINEZ Notary Public - State of Florida My Comm. Expires Sep 16, 2017 Commission # FF 054717 Plans Examiner Zoning Structural Review Clerk CFN: 20150631408 BOOK 29798 PAGE 3304 DATE:10/01/2015 10:20:15 AM DEED DOC 1,590.00 HARVEY RUVIN, CLERK OF COURT, MIA-DADE CTY THIS INSTRUMENT PREPARED BY AND RETURN TO: ROSEMARY VAN EXCEL TITLE, INC. 2700 N 29TH AVENUE, SUITE 108 HOLLYWOOD, FL 33020 15208P WARRANTY DEED This Indenture made this 30th day, of September, 2015, BETWEEN LYONEL NOEL, A SINGLE LL,,I_ MAN, GRANTOR* and INTER-MANC., A FLORIDA CORPORATION, of 43 N.W. 110TH STREET, MIAMI, FL 33168, GRANTEE* WITNESSETH, That said Grantor, for and in consideration of the sum of TEN AND 001100'S ($10.00) Dollars and other good and valuable consideration to said Grantor in hand paid by said Grantee, the receipt whereof is hereby acknowledged, has granted, bargained and sold to the Grantee and Grantee's heirs forever the following described land located in the County of MIAMI-DADE, State of Florida, to -wit: Lot 29, in Block 220, of MIAMI SHORES EXTENSION, according to the Plat thereof, as recorded in Plat Book 43, at Page 40 of the Public Records of MIAMI-DADE County, Florida. SUBJECT TO TAXES FOR THE YEAR 2015, NOT YET DUE AND PAYABLE. SUBJECT TO ALL CONDITIONS, EASEMENTS, RESTRICTIONS AND LIMITATIONS OF RECORD, IF ANY. FOLIO NO. 11-2136-003-0610 and said Grantor does hereby fully warrant the title to said land, and will defend the same against the lawful claims of all persons whomsoever. *Singular and plural are interchangeable as context requires IN WITNESS WHEREOF, Grantor has hereunto set Grantor's hand and seal this day and yearfirst above written. WITNESS SS OELPrint Nam of Wits C�0_&or) up 4 Print Name of Witness: f}lgflifoi Pdf oO10 Grantor's Address: 8321 NW 54TH STREET, LAUDERHILL, FL 33351 STATE OF FLORIDA COUNTY OF BROWARD The foregoing instrument was acknowledged before me this 30th day of September, 2015, by LYONEL NOEL, A SINGLE MAN who is/are personally known to me orwho has/have produced FL Driver's License/Passport/Res! dent Card as identification and who did take an oath. NOTARY PUB Commission E piration L1NDA SAINTS MY COMMISSION #FF205246 EXPIRES March of 3,ig Florida Notary public -State Detail by Entity Name Page 1 of 2 Detail by Entity Name Florida Profit Corporation INTER -MALL INCI Filing Information Document Number FEI/EIN Number Date Filed Effective Date State Status Principal Address 8260 SW 2ND ST MIAMI, FL 33144 Changed: 07/02/2013 Mailing Address 8260 SW 2ND ST MIAMI, FL 33144 Changed: 07/02/2013 P07000077502 26-0479314 07/06/2007 07/05/2007 FL ACTIVE Registered Agent Name & Address JIMENEZ,.EUCLI'DE81 8260 SW 2ND ST MIAMI, FL 33144 Address Changed: 07/02/2013 Officer/Director Detail Name & Address Title P JIMENEZ, EUCLIDES 8260 SW 2ND ST MIAMI, FL 33144 Annual Reports Report Year Filed Date http://search. sunbiz. org/Inquiry/CorporationSearchISearchResultDetail?inquirytype=Entity 2/ 12/2016 This Document Prepared By and Return to: Euclides Jimenez 8260 SW 2 ST Miami, FL 33144 Power of Attorney Know All Men By These Presents That `Euclides Jimenez�President of INTER -MALL, INC. (hereinafter "Principal') has made, constituted and appointed, and by these presents does make, constitute and appoint Danny Crespo (Agent) (hereinafter "Attorney -in -Fact'), whose address is 8351 SW 4 ST, Miami, FL 33144 as my true and lawful attorney for me and in his name, place, and stead, to do and perform any and all of the following acts, deeds and things, to wit: (1) to contract or agree to buy, to buy, and to encumber and mortgage the following described property: Lot 29, in Block 220, of MIAMI SHORES EXTENSION, according to the plat thereof, as recorded in plat Book 43, at page 40 of the Public Records of MIAMI-DADE County, Florida (2) to make, accept, receive, sign, seal, execute, acknowledge and deliver deeds, mortgages, promissory notes and other closing documents related to the purchase, sale, and/or finance of the above -described property. (3) to sign any and all documents and pull required construction permits, to hire a contractor, to make decisions on work or repairs to be performed on the above real estate property. Giving and granting unto my said Attorney -In -Fact for the above referred real property, full power and authority to do and perform all and every act and thing whatsoever requisite and necessary to be done by the premise, as fully, to all intents and purposes, as I might or could do if personally present, hereby ratifying and confirming all that my said attorney shall lawfully do or cause to be done by virtue hereof This durable power of attorney is not terminated by subsequent incapacity of the principal except as provided in Chapter 709, Florida Statutes. This durable power of attorney shall expire on December 31, 2016. In Witness Whereof, we have hereunto set their hands and seals this3 _ day of December, 2015 and delivered in my presence: Witness #1 Printed Name i gnature �I W i #2 Printed Name STATE OF FLORIDA COUNTY OF Broward The foregoing instrument was acknowledged before me #tis 3 �aeead�es�Q�S, by Euelides Jimenez, President of INTER MALL, INC. who (" 1 is are person y mown to me or [produced T as identification. �Sit Printed Notary Name Commission Expires: FMY B�pY�ib F9"M �jMMyyq,F=Q* - Durable Power of Attorney —Page 2 U STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD 1940 NORTH MONROE STREET TALLAHASSEE FL 32399-0783 RODRIGUEZ, LUIS 0 TOP CRAFTS INC 14619 SW 99 ST MIAMI FL 33186 Congratulations! With this license you become one of the nearly one million Floridians licensed by the t of Business and Professional Regulation. Our professionals range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong, Every day we work to improve the way we do business in order to serve you better. For information about our services, please log onto www.myfloridalicense.com, There you can find more information about our divisions and the regulations that impact you, subscribe to department newsletters and learn more about the Departments initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida. and congratulations on your new license! RICK SCOTT, GOVERNOR (850) 487-1395 STATE OF FLORIDA DEPARTMENT -OF BUSINESS AND PROFESS109AL REGULATION CGC1509617.ISSUED:' 05/25/2016 CERTIFIED GENERAL: CONTRACTOR- RobRIGUEZ,,LUI,,,o TOP CRAFTS INC rX IS CERTIFIED under the provisions of Ch-489 FS ExpVabon me ; AUG 311. 2018 DETACH HERE KEN LAWSON, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD cum= J The GENERAL CONTRACTOR Named below IS CERTIFIED Unde(the provisions ofthapter 489 FS. I Eipiratiomdate: -AUG 31.,2018 - - RODkI6UEZ:,LUIS 0 ,,TOP CRAFTS INC t S 14619 S,W,99THSR'�TRE MIAMP - ISSUED: 05/2512016 DISPLAY AS REQUIRED BY LAW SEQ# L1605250001000 .....„ �17CF76 Local Business Tax Receipt Miami -Dade County, State of Florida --THIS IS NOT A BILL - DO NOT PAY 65.30167 BUSINESS NAME/LOCATION TOP CRAFTS INC 14619SW99ST MIAMI FL 33186 OWNER TOP CRAFTS INC Worker(s) 1 008462 RECEIPT NO. EXPIRES RENEWAL SEPTEMBER 30, 2017 6800628 Must be displayed at place of business Pursuant to County Coale Chapter 8A -Art. 9 & 10 SEC, TYPE OF BUSINESS 196 SPECIALTY ENGINEERING CONTRACT PAYMENT RECEIVED E090f}540 By TAX COLLECTOR $75.00 07/11/2016 CREDITCARD-16-037952 This'Local Business Tax Receipt only confirms payment of the Local Business Tax. The Receipt is not a license, permit, or a certification of the holdor s qualifications, to do business. Holder must comply with any governmental or nongovernmental regulatory laws and requirements which apply to the business. The RECEIPT NO. above must be displayed on all commercial vehicles - Miami -Dade Code Sec fla-276. For more information, visit Local Business Tax Receipt Miami -Dade County, State of Florida -THIS IS NOT A BILL - DO NOT PAY 5629960 BUSINESS NAMEILOCATION TOP CRAFTS INC 14619 SW 99 ST MIAMI FL 33186 OWNER TOP CRAFTS INC Worker(s) 1 RECEIPT NO. EXPIRES RENEWAL SEPTEMBER 30, 2017 5872453 Must be displayed at place of business Pursuant to County Code Chapter 8A - Art. 9 & 10 SEC, TYPE OF BUSINESS PAYMENT RECEIVED 196 GENERAL BUILDING CONTRACTOR BY TAX COLLECTOR CGC1509617 $75.00 07/11/2016 CREDITCARD-16-037952 This Local Business Tax Receipt only confirms payment of the Local Business Tax. The Receipt is not a license, permit, or a certification of the holder's qualifications, to do business. Holder must comply with any governmental or nongovernmental regulatory laws and requirements which apply to the business. The RECEIPT 1110. above must be displayed on all commercial vehicles - Miami -Dade Code Sea 6a-276. For more itt11011astiOn, visit tKN/1rl.mltlmida ` ,{�Y}taX4�011@4`fOr AC40 V CERTIFICATE OF LIABILITY INSURANCE ATE NYYY D �30�2017 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Mar Zunia NAME: g PHONE (305) 630-4777 ac No; (305)279-3022 Gil, Garden, Avetrani Insurance Group 10689 N. Kendall Drive E-MAIL ADDRESS: mg agg g' zuni @ ai com INSURER(S) AFFORDING COVERAGE NAIC # Suite 208 INSURER A:Security National Insurance Company Miami FL 33176 INSURED INSURER B Ma fre Insurance Company of FL INSURERCNational Liability 6 Fire Insurance Top Crafts, Inc. INSURERD: 14619 SW 99 Street INSURER E : INSURERF: Miami FL 33186 COVERAGES CERTIFICATE NUMBER_CL16112809373 RFVISION N11MRFR' THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTR OF INSURANCE L ADDTYPE S R POLICY NUMBER MM/DDY/YEYri MM/DDT LIMITS A X COMMERCIAL GENERAL LIABILITY CLAIMS -MADE Y OCCUR SES1339270 7/22/2016 7/22/2017 EACH OCCURRENCE $ 1,000,000 DAMAGE To RENTED PREMISES Ea occurrence $ 100, 000 MED EXP (Any one person) $ 2,500 PERSONAL & AOV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: X POLICY JECT LOC OTHER: GENERAL AGGREGATE $ 2,000,000 PRODUCTS - COMP/OP AGG $ 2,000,000 $ B AUTOMOBILE X LIABILITY ANY AUTO ALL OSCHEDULED AUTOS AUTOS HIRED AUTOS NON -OWNED AUTOS 4150160013442 11/29/2016 11/29/2017 COMBINED SINGLE LIMIT Ea accident $ 1,000,000 BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE Per accident $ UMBRELLA LIAB EXCESS LIAR HCLAIMS-MADE OCCUR EACH OCCURRENCE $ AGGREGATE $ DED I I RETENTION$ $ C WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y / N ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? F (Mandatory in NH) If yes, describe under DESCRIPTION OF OPERATIONS below N / A V9WC723858 12/20/2016 12/20/2017 PER OTH- STATUTE ER E.L. EACH ACCIDENT $ 1,000,000 E.L. DISEASE - EA EMPLOYE $ 1 000 000 E.L. DISEASE - POLICY LIMIT $ 1 000.000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached If more space Is required) License number: CGC 1509617 CERTIFICATE HOLDER CANCFI I A'TIAN SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Miami Shores Village THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Building Department ACCORDANCE WITH THE POLICY PROVISIONS. 10050 NE 2nd Ave AUTHORIZED REPRESENTATIVE Miami Shores, FL 33138 Derek Rodriguez/MARGY- ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25 (2014/01) The ACORD name and logo are registered marks of ACORD INS025 nol4nn This Document Prepared By and Return to: Euclides Jimenez 8260 SW 2 ST Miami, FL 33144 Power of Attorney Know All Men By These Presents That Euclides Jimenez, President of INTER -MALL, INC. (hereinafter "Principal') has made, constituted and appointed, and by these presents does make, constitute and appoint Danny Crespo (Agent) (hereinafter "Attorney -in -Fact'), whose address is 8351 SW 4 ST, Miami, FL 33144 as my true and lawful attorney for me and in his name, place, and stead, to do and perform any and all of the following acts, deeds and things, to wit: (1) to contract or agree to buy, to buy, and to encumber and mortgage the following described property: Lot 29, in Block 220, of MIAMI SHORES EXTENSION, according to the plat thereof, as recorded in plat Book 43, at page 40 of the Public Records of MIAMI-DADE County, Florida (2) to make, accept, receive, sign, seal, execute, acknowledge and deliver deeds, mortgages, promissory notes and other closing documents related to the purchase, sale, and/or finance of the above -described property. (3) to sign any and all documents and pull required construction permits, to hire a contractor, to make decisions on work or repairs to be performed on the above real estate property. Giving and granting unto my said Attorney -In -Fact for the above referred real property, full power and authority to do and perform all and every act and thing whatsoever requisite and necessary to be done by the premise, as fully, to all intents and purposes, as I might or could do if personally present, hereby rating and confirming all that my said attorney shall lawfully do or cause to be done by virtue hereof This durable power of attorney is not terminated by subsequent incapacity of the principal except as provided in Chapter 709, Florida Statutes. This durable power of attorney shall expire on December 31, 2016. In Witness Whereof, we have hereunto set their hands and seals thiZj day of December, 2015 � V\(AV1W �IV4 Wt n ss #2 Printed Name STATE OF FLORIDA COUNTY OF Broward The foregoing instrument was acknowledged before me this �Ld4yjof-December,-24L5, by Euclides Jimenez, President of INTER -MALL, INC. who ["tis are personally known to me or [ produced as identification. No ary Sig ure , :C CQQd !iGue2 Printed Notary Name Commission Expires: JAGWEUNEROMIGUEZ ' Y w COMMISSION t FF 916MM EXPIRES: September 9, 2019 Durable Power of Attorney — Page 2 i .. DAVID A. DACOUISTO, AICP PLANNING & ZON'NG DIRECTOR DEVELOPMENT ORDER '. tavni(/iShorej h File Number: PZ-03-16-201627 Property Address: 43 NW 11011' Street Property Owner/Applicant: Address: Agent: Address: 10050 N.E. SECOND AVE. MIAMI SHORES, FLORIDA 33138-2382 Telephone: (305) 795-2207 Fax: (305) 756-8972 Inter Mall Inc 43 NW 110'h Street, Miami Shores, FL Harry Sanchez 4175 SW 98 Ct., Miami, FL ra Whereas, the applicant Inter Mall Inc (Owner), has filed an application for site plan review before the Planning Board on the above property. The applicant sought approval as follows: Pursuant to Articles IV, V and A of Appendix A Zoning, Sec. 400 Schedule of Regulations and Sec. 600. Site plan review and approval required. Garage conversion. Whereas, a public hearing was held on April 28, 2016 and the Board, after having considered the application and after hearing testimony and reviewing the evidence entered, finds: 1. The application was made in a manner consistent with the requirements of the Land Development Code of Miami Shores Village. 2. The conditions on the property and the representations made at the hearing merit consideration and are consistent with the requirements of the Land Development Code. The Board requires that all further development of the property shall be performed in a manner consistent with the site plan, drawings, and the conditions agreed upon at the hearing: 1) Approval is granted as shown on the plans submitted and made a part of this approval to convert an existing 200 sf attached carport at the side of the residence to a family room. 2) The parking spaces identified on Sheet A-1 do not comply with zoning requirements for setbacks and must be redesigned to the satisfaction of the planning director in compliance with all zoning requirements before any building permit may be issued for the project. Page 1 of 2 3) The applicant to maintain 2 legal parking spaces on the plot. 4) Applicant to apply for and obtain all required building permits from the Building Department before beginning work. 5) Applicant to apply for and obtain all necessary permits and approvals from outside agencies before beginning work. 6) An erosion and sedimentation plan subject to review and approval by the building official is required if ground cover is removed or as required by the building official. Properly installed soil erosion measures (silt fences, straw barriers, etc.) and anti -tracking area at all construction entrances are required to be put in place and maintained if ground cover is removed or as required by the building official. Required erosion control measures must be in place prior to footings inspection. 7) Applicant to obtain all required permits and approvals from the Miami - Dade Department of Regulatory and Economic Resources, Environmental Plan Review Division (DRER, EPRD) and the Miami - Dade Department of Health (DOH/HRS) as required. 8) Applicant to meet all applicable code provisions at the time of permitting. 9) Applicant to complete a covenant in the form of a "Declaration of Use" assuring the property is used only for a single family purpose, record the covenant with the Miami -Dade County Recorder and provide the planning director with a copy of the recorded document prior to the final inspection by the Building Official. 10)This zoning permit will lapse and become invalid unless the work for which it was approved is started within one (1) year of the signing of the development order by the board chair, or if the work authorized by it is suspended or abandoned for a period of at least one (1) year. The application with conditions was passed and adopted this 28t" day of April, 2016 by the Planning and Zoning Board as follows: Mr. Abramitis Yes Mr. Busta Yes Mr. Reese Yes Mr. Diaz Yes Chairman Fernandez Absent ,�� I �o Date rt Abramitis Chairman, Planning Board Page 2 of 2 MIAMI SHORES PLANNING AND ZONING BOARD Planning and Zoning Department Staff Report Hearing Date Aril 28, 2016 Meeting Time 7:00 P.M. File Number PZ-03-16-201627 Folio Number 11-2136-003-0610 Owner Inter Malt Inc Applicant Same Agent Harry Sanchez Property Address 43 NW 110 Street Legal Description MIAMI SHORES EXT PB 43-40 LOT 29 BLK 220 LOT SIZE 75.000 X 122 OR 12809-582 0286 1 COC 26052-1504 10 2007 5 Assessor's Building Value N/A Property S . Ft. 9,150 1 Building S . Ft. 1,297 Flood Zone X Zoning R15 Future Land Use Designation Single Family Residential Existing Use One -family dwelling Comprehensive Plan Consistency Yes Existinq Structure 1 story; 3 bed/1 bath Year Built 1940 Subject Pursuant to Articles IV, V and VI of Appendix A Zoning, Sec. 400 Schedule of Regulations and Sec. 600. Site plan review and approval re uired. Garage conversion. Action Required Approve, Approve with Conditions, or Deny the Application Other Required Approvals Village Building Permits MDDRER/EPRD Staff Report David A. Dacquisto, Director, Planning and Zoning Report Date March 29, 2016 Background The applicant is proposing a garage conversion. The property is an interior plot. The applicant is proposing to convert an existing 200 sf car port to a family room with closet laundry. The family room will accessed from both the living room and dining room. The applicant will provide 2 parking spaces on the plot in front of the residence. Analysis The proposed driveway parking pad is located 5 ft. from the side plot line. A 10 ft. side yard setback is required. The conversion is compatible with the 1940's residence and the new windows along the family room wall will blend with the existing architecture and provide visual relief along the wall. The design is compatible with the neighborhood and community. The proposal is consistent with the technical provisions of the Zoning Code except as noted. Recommendation In acting on a site plan, the Planning Board must make a finding that the proposed improvements comply with the regulations and are harmonious with the community, as required in Articles IV, V and VI of Appendix A Zoning, Sec. 400 and Sec. 600, of the Code of Ordinances, and, in that regard, may add further conditions or delete or modify staff recommended conditions, deny the application, or continue the item for future consideration. Planning and Zoning staff recommends APPROVAL of the site plan to convert an existing 200 sf attached carport at the side of the residence to a family room, based on the foregoing analysis with a finding that it is consistent with the technical provisions of the Code except as noted and subject to the following conditions. Should the board find that the applicant merits approval, staff recommends that the following conditions apply: 1) Approval is granted as shown on the plans submitted and made a part of this approval to convert an existing 200 sf attached carport at the side of the residence to a family room. 2) The parking spaces identified on Sheet A-1 do not comply with zoning requirements for setbacks and must be redesigned to the satisfaction of the planning director in compliance with all zoning requirements before any building permit may be issued for the project. 3) The applicant to maintain 2 legal parking spaces on the plot. 4) Applicant to apply for and obtain all required building permits from the Building Department before beginning work. 5) Applicant to apply for and obtain all necessary permits and approvals from outside agencies before beginning work. 6) An erosion and sedimentation plan subject to review and approval by the building official is required if ground cover is removed or as required by the building official. Properly installed soil erosion measures (silt fences, straw barriers, etc.) and anti - tracking area at all construction entrances are required to be put in place and maintained if ground cover is removed or as required by the building official. Required erosion control measures must be in place prior to footings inspection. 7) Applicant to obtain all required permits and approvals from the Miami -Dade Department of Regulatory and Economic Resources, Environmental Plan Review Division (DRER, EPRD) and the Miami -Dade Department of Health (DOH/HRS) as required. 8) Applicant to meet all applicable code provisions at the time of permitting. 9) Applicant to complete a covenant in the form of a "Declaration of Use" assuring the property is used only for a single family purpose, record the covenant with the Miami -Dade County Recorder and provide the planning director with a copy of the recorded document prior to the final inspection by the Building Official. 10)This zoning permit will lapse and become invalid unless the work for which it was approved is started within one (1) year of the signing of the development order by Page 2 of 3 027 PZ-03-16-201627 Inter Mall j the board chair, or if the work authorized by it is suspended or abandoned for a period of at least one (1) year. 027 PZ-03-16-201627 Inter Mall Page 3of3 % ORES\ Miami Shores Village` sa rRRf r, rr� f Building Department ' #par 10050 NE 2 Ave \ / Miami Sho,-es FL 33138 �• ORIO _w Permit NO. RC-3-17-723 Type: Building (Residential) Workciass: Alteration _. Permit Status: Approved issue Date: 4/17/2017 Expires: 03118/2019 INSPECTION REQUESTS: (305l762-4949 or log on at https://bldg.msvfl.gov/energov_prod/selfservice Requests must be received by 3:30pm WORK IS ALLOWED: MONDAY THROUGH FRIDAY, 8:00AM - 7:00PM r SATURDAY 8:00AM - 6:O0PM. NO WORK IS ALLOWED ON SUNDAY OR HOLIDAYS BUILDINGAND ROOFING INSPECTIONSARE DONE MONDAYTHROUGH FRIDAY . NO INSPECTION WILL BE MADE UNLESS rHE PERMIT CARD IS DISPLAYED AND HAS BEENAPPROVED . PLANSARE READILY AVAILABLE. IT IS THE PERMIT APPLICANT'S RESPONSIBILITY TO ENSURE THAT WORK IS ACCESSIBLE AND EXPOSED FOR INSPECTION PURPOSES. NEITHER THE BUILDING OFFICIAL NOR THE CITY SHALL BE LIABLE FOR EXPENSE ENTAILED IN THE REMOVAL OR REPLACEMENT OF ANY MATERIAL REQUIRED TO ALLOW INSPECTION . Owner's Name: Job Address: 43 NW 110 ST Miami Shores, FL 33168-4318 POST ON SITE 1121360030610 Owner's Phone: (786)231-7789 Total Square Feet: 800 dotal Job Valuation: $ 32,000.00 Contractor(s) Phone Address TOP CRAFTS INC (305)258-1439 14619 SW 99 ST, MIAMI, FL 33186 Description: INTERIOR REMODELING & CARPORT CONVERSION 08-28-2017 I. Naranjo : HOLD. Contractor need to schedule meeting with BO. , e engineer of record need to inspect all existing structural members artd provih'ade repair details Contractor of record need to schedule a meeting with the buildinc Including gable end walls official and the engineer of record on site. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Page 1 of 1 L1Q hVl C 6 M J NSPEC ION RECOR.`/l. INSPECTION Foundation Stemwall Slab Columns (1st Lift) Columns (2nd Lift) Tie Beam Truss/Rafters Roof Sheathing Bucks Interior Framing x Insulation Ceiling Grid Drywall Y � Firewall Wire Lath Pool Steel Pool Deck Final Pool Final Fence Screen Enclosure Driveway Driveway Base Tin Cap In -Progress Roof Installation Roofing Final Shutters Attachment Final Shutters Rails and Guardrails ADA compliance DATE I INSP DOCUME Soil Bearing Cert Soil Treatment Cert Floor Elevation Survey Reinf Unit Mas Cert Insulation Certificate Spot Survey Final Survey Truss Certification STRUCTURAL COMMENTS WINDOWS: DOORS INSPECTION DATE INSP Attachment PUBLIC WORKS INSPECTION DATE INSP Excavation ELECTRICAL INSPECTION DATE INSP Temporary Pole 30 Day Temporary Pool Bonding Pool Deck Bonding Pool Wet Niche Underground Footer Ground Slab Wall Rough Ceiling Rough Rough Telephone Rough Telephone Final TV Rough TV Final Cable Rough Cable Final Intercom Rough Intercom Final Alarm Rough Alarm Final Fire Alarm Rough Fire Alarm Final Service Work With 210 ELECTRICAL COMMENTS III INSPECTION DATE INSP Final Sprinkler Final Alarm INSPECTION I DATE I INSP Rough Water Service 2nd Rough Top Out Fire Sprinklers Septic Tank Sewer Hook-up Roof Drains Gas LP Tank Well Lawn Sprinklers Main Drain Pool Piping Backflow Preventor Interceptor Catch Basins Condensate Drains HRS Final I PLUMBING COMMENTS I INSPECTION I DATE INSP Underground Pipe R Ventilation Rough Hood Rough Pressure Test Final Hood Final Ventilation Final Pool Heater Final Vacuum iLA MECHANICAL COMME Property Search Application - Miami -Dade County Page l of 1 OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-2136-003-0610 Property Address: 43 NW 110 ST Miami Shores, FL 33168-4318 Owner EUCLIDES JOSE JIMENEZ JR Mailing Address 8260 SW 2 ST MIAMI, FL 33144 USA PA Primary Zone 0800 SGL FAMILY - 1701-1900 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/1/0 Floors 1 Living Units 1 Actual Area 1,572 Sq.Ft Living Area 1,018 Sq.Ft Adjusted Area 1,297 Sq.Ft Lot Size 9,150 Sq.Ft Year Built 1940 Assessment Information Year 2019 2018 2017 Land Value $206,472 $196,886 $196,886 Building Value $81,244 $81,244 $81,244 XF Value $1,600 _ $1,620 $1,640 Market Value $289,316 $279,750 $279,770 Assessed Value $289,316 $279,750 $279,770 Benefits Information Benefit Type 2019 2018 2017 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). (Short Legal Description I MIAMI SHORES EXT PB 43-40 LOT 29 BLK 220 LOT SIZE 75.000 X 122 OR 12809-582 0286 1 COC 26052-1504 10 2007 5 Generated On : 7/10/ Taxable Value Information 2019 2018 2 County Exemption Value $0 $0 Taxable Value $289,316 $279,750 $279.. School Board Exemption Value $0 $0 Taxable Value $289,316 $279,750 $279. City Exemption Value $0 $0 Taxable Value $289,316 $279,750 $279.. Regional Exemption Value $0 $0 Taxable Value $289,3161 $279,750 ................. $279 Sales Information Previous OR Book - Price Qualification Description Sale Page 30693- Corrective, tax or QCD; min 09/19/2017 $100 2097 consideration 29798 09/30/2015 $265,000 Qual by exam of deed 3304 26052- Sales which are disqualified as a rest 10/01/2007 $0 1504 of examination of the deed 02/01/1986 $60,000 12809- Sales which are qualified 0582 The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appra and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp https://www8.miatnidade.gov/Apps/PA/propertysearch/ 7/10/2019 Detail by Entity Name Page 2 of 2 Report Year Filed Date 2015 02/21/2015 2016 03/02/2016 2017 02/09/2017 Document Images 02/09/2017 -- ANNUAL REPORT I View image in PDF format 03102/2016 -- ANNUAL. REPORT View image in PCfF format -_-_ANNUAL REPORT View image in PDF forn'1af. 01/2712014 -- ANNUAL REPORT View image in PDF format 07102!2013 - ANNUAL REPORT View image in PDF format 03108/2012 -- ANNUAL REPORT M16/2011 -- ANNUAL. REPORT 0412W2010 -- ANNUAL REPORT 03l2612009 -- ANNUAL REPORT 04/21/2006 - ANNUAL REPORT 07/06/2007 -- Domestic Profit .u; da ^epartm�nl: a G1:.1:e, C`:r,"',I JI (,, P.; 2t:IIn http://search. sunbiz.org/Inquiry/CorporationSearchISearchResultDetail?inquirytype=Entity... 7/ 10/2019 Detail by Entity Name Page 1 of 2 Flonda Department of State �,. p; jda�✓tIff�, �rf i . �i �1�� irr.}1 hs!1'�i�'rP'?: Department of State / Division of Corporations / Search Records / Detail By Document Number / Detail by Entity Name Florida Profit Corporation INTER -MALL INC Filing Information Document Number FEI/EIN Number Date Filed Effective Date State Status Last Event Event Date Filed Event Effective Date Principal Address 8260 SW 2ND ST MIAMI, FL 33144 Changed: 07/02/2013 Mailing Address 8260 SW 2ND ST MIAMI, FL 33144 P07000077502 26-0479314 07/06/2007 07/05/2007 FL INACTIVE ADMIN DISSOLUTION FOR ANNUAL REPORT 09/28/2018 NONE Changed: 07/02/2013 Registered Agent Name & Address JIMENEZ, EUCLIDES 8260 SW 2ND ST MIAMI, FL 33144 Address Changed: 07/02/2013 Officer/Director Detail Name & Address Title P JIMENEZ, EUCLIDES 8260 SW 2ND ST MIAMI, FL 33144 Annual Reports DIVISION OF CORPORATIONS http://search. sunbiz.org/Inquiry/CorporationSearchISearchResultDetail?inquirytype=Entity... 7/ 10/2019 FORM R405-2014 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include L� This checklist d . . A Form R405 report that documents that the Proposed Design complies with Section .... ...... • • • • • R405.3 of the Florida Energy Code. This form shall include a summary page "':" indicating home address, a -ratio and the pass or fail status along with summary • • • • • • areas and types of components, whether the home was simulated as a worst -case- : ""' • • ... of the compliance software tool, name of individtia9": :'. orientation, name and version .. .. completing the compliance report (1 page) and an input summary checklist thatGag . .. ...... be used for field verification (usually 4 pageslmay be greater). • • • • • • Qj Energy Performance Level (EPL) Display Cant (one page) ' 0� Mandatory Requirements(three pages) Required prior to CO for the Performance Method., Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4. 1. 1 - one page) d A completed Envelope Leakage Test Report(usuaily one page) M if Form R405 duct leakage We indicates anything other than "default leakage" then a completed Form R405 Duct Leakage Test Re . ,, .uQa e. } EnergyGauge(& - USRCSB v5.1 8l4r2016 11:58:45 AM Page 1 of 1 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Carport Enclosure and Remodeling Street: 43 NW 110th SL City, State, Zip: Miami Shores, FL, 33168 Owner Design Location: FL, Miami Builder Name: Permit Office: Permit Number. Jurisdiction: 231000 County:: Miami -Dade (Florida Climate Zone 1 ) 1. New construction or existing Addition 9. Wall Types (1392.2 sgft.) Insulation Area a. Concrete Block - Int insul, Exterior R=4.1 1392.20 ft2 2. Single family or multiple family Single-family b. WA R= ft2 3. Number of units, d multiple famity 1 c. WA R= ft2 4. Number of Bedrooms(Bedrms in Addition) 3(0) d. WA R= fr 10. Ceiling Types (1572.0 so.) InstIti V . Area 5. Is this a worst case? No a. Under Attic (Vented) : .' . 11=300 • 01572.00W* • • 6. Conditioned floor area above grade (It) 1572 b. WA • • • ...... R= • • • ft2 • • • c. WA R= ..' . .w..:. Conditioned floor area below grade (ft2? 0 11. Duds • • • : • • R • fF 7. Windows(221.7 sgft.) Description Area a. Sup: Attic, Ret: Main, AH: Main. • •. :...:. 8 s16' •' a. U-Factor. Dbl, U=0.65 221.69 ft2 • • • • . • .. • . SHGC: SHGC=0.30 • • • • • • 12. Cooling systems • • • • ..: • .' kBkrtNr . Effiaenry b. U-Factor. WA it a. Central Unit 42.0* tEER:1eXV �:' SHGC: • c. U-Factor WA ft2 • • . . 000000 SHGC: 13. Heating systems 0 kt &Nr * * Efficiency . d. U-Factor. WA ft2 a. Electric Strip Heat • • .246 COP:tm": SHGC: • • Area Weighted Average Overhang Depth: 1,000 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems -Replacement equipment a. Electric Cap: 50 gallons 8. Floor Types (1572.0 sgft.) Insulation Area EF:0.920 a. Crawlspace R=13.0 1672.00 f12 b. Conservation features b. NIA R= fe Heat Recovery Unit o WA R= ft2 15. Credits Pstat Glass/FloorArea: 0.141 Total Proposed Modified Loads: 64.61 Total Baseline Leads: 68.02 i hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: . ,bw `....A0W.. ... ;A DATE: .-_.._..... ........... ....... .......�...-...._.. -- _._._.._. I hereby certify that this building, as designed, is in compliance with the Florida Energy CJode�. OWNER/AGENT:. DATE: --- _..�.......... _._ _. Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: ._ ....................... ....... ...... 0. 'Z i, jL.+0.... - .. fib WIE - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. 8/4/2016 11:58 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 =ORM R405-2014 PROJECT Title: Carport Enclosure and Remo Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1572 Lot # Owner. Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 43 NW 110th St. Permit Office: Cross Ventilation: County: Miami -Dade Jurisdiction: 231000 Whole House Fan: City, State, Zip: Miami Shores, Family Type: Single-family FL, 33168 New/Existing: Addition Comment: CLIMATE IECC Design Temp lnt Design Temp Heating Design Daily Temp j V Design Location TMY Site Zone 97.5 °% 2.5 °% Winter Summer Degree Days • Wisture Range FL, Miami Fl MIAMt INTL _AP 1 51 90 70 75 • • • - ; 49.5 • 56 • aw BLOCKS ...:.. Number Name Area Volume •.. �- _ • • • • • • _-_.--- ._.._......--.-_ _ -1 1 Btodct 1572 12911 • • . • 0. - ----_ SPACES """ • Number Name Area Volume Kitchen Occupants Bedrooms 1*f11 • Finished Caoleri Heated._...... _i. ...... ,.._•.•_.•_ram.•..._........._ 1 Main 1340 11055 Yes 4 3 1 Yes .:::*:Yes Yes Family Room Additi 232 1856 No 4 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R Value Tile Wood Carpet _. >> 1 Crawlspaoe Main t 54 ft 0 1340 ft2 13 0 1 0 i 2 Cmwlspace Family Room Add 46 ft 0 232 ft2 13 ROOF ! Roof Gable Roof Solar SA Emitt Emitt Deck Pitch 1f # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Barrel tile 1657 ft2 262 R2 Medium 0.96 No 0.9 No 0 18A ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC Full attic Vented 300 1572 fe N N 8/412016 11:58 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 CEILING Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type .. ...... . .. ... . ... ........ ........ ... .... . . .... ..... ... .. . . ..................... ............. - .. ..... .... .. ........... ............... ......... . . .... ............. ...... ... . . .. . .......... .... I Under Attic (Vented) Main 30 Blown 1340 ft2 0.11 Wood 2 Under Attic (Vented) Family Room Add 30 Blown 232 ft' 0,11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below ..... ........ pace -Wall.Type . ... ....... .............. S........... 114slue ......... ........ Ft Ia.. ... Traction Absor. Grade7a I N Exterior Concrete Block - Int Insul Main 4.1 40 8 3 330.0 ft2 D 0.75 0 2 E Exterior Concrete Block - Int Insul Main 4.1 36 8 3 297.0 ftz 0 015 0 3 S Exterior Concrete Block - Int Insul Main 4.1 50 8 3 412.5 ft? 0 0.75 0 4 W Exterior Concrete Block - Int Insul Main 4.1 12 8 96.0 ft- 0 0.75 0 5 W Exterior Concrete Block - Int InsBbmily Room 4.1 22 1 8 176.7 ft2 0 015 0 6 N Exterior Concrete Block - Int lnsFAmily Room 4A 10 8 80.0 ft2 • *6• 0.75 0 DOORS • # Ornt Door Type Space Storms U-Value VKM H Area: .eight 0 Jn aFt 0 In .......... ..... ..... - .... ... ...... Wood Main None . .. ... . . ........ ........................... .. .46 *6 8 2 S Wood Main None .46 • 949. WINDOWS 0000% Orientation shown is the entered, Proposed orientation. 181111 Wall Overrstrig Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Idt Stftde Screening I N 1 Metal .. .......... . . .. . ........... Double (Tinted) Yes 0.65 0.3 39.3 It' I ft 0 in I ft 7 in Drapes/blinds None 2 N I Metal Double (Tinted) Yes 0.65 0.3 &0 ft2 1 ft 0 in 1 ft 7 in Drapestblinds None V 3 N 1 Metal Double (Tinted) Yes 0.65 0.3 4.7 ft2 1 It 0 in 1 ft 7 in Drapes/bfinds None 4 E 2 Metal Double (Tinted) Yes 0.65 0.3 262 fF I ft0in I ft 7 in Drapes/blinds None V 5 S 3 Metal Double (Tinted) Yes 0.65 0.3 39.3 IF 1 ItOin I ft7in Drapes/blinds None 1/ 6 S 3 Metal Double (Tinted) Yes 0.65 0.3 26.2 fie I ft 0 in I ftO in Drapes/blinds None 7 W 4 Metal Double (Tinted) Yes 0.65 0.3 26.2 ft2 I ft 0 in I ft 0 in Drapes/blinds None 8 W 5 Metal Double (Tinted) Yes 0.65 0.3 41.6 W 1 It 0 in 1 ft 0 in Drapes/blinds None 9 N 6 Metal Double (Tinted) Yes 0,65 0.3 13.1 f12 I It 0 in i ff 4 in Drapes/blinds None INFILTRATION Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 - ... .. ............... ...... . .... I Wholehouse .... ...... .............. ..... Proposed ACH(50) .000157 ... ................. ........... . .. . . ... 645.5 ..... .. ....... ......... . . ....... . ...... 36A4 . . .......... 66.65 .. ....... ........ '108 3 8/412016 11:58 AM EnergyGaugeO USA - FlaRe-S2014 Section R405A. 1 Compliant Software Page 3 of 4 =ORM R465-2014 HEATING SYSTEM V,.. # System Type - - Subtype- _._. ...._.. Efficiency _........ _ Capacity Block -.. Ducts 1 Eledric Strip Heat None COP:1 24.55 kBtuthr 1 sys#1 COOLING SYSTEM 1 Central Unit Split Efficiency Capacity Air Flow SHR Block Ducts ........... ............ ..... .... ....__..................................... .......... ......... .._........ .......................................... .............__................................................ ................. .. SEER: 16 42 kBtulhr 1260 cfrn 0.75 1 sys#1 HOT WATER SYSTEM # System Type - SubType.._..Location EF Cap Use SetPnt Conservation 1 Electric None Family Room ptBWon 50 gal 60 gal 120 deg Heat Recovery Unit SOLAR HOT WATER SYSTEM 0000 FSEC 2;0110&9r Stclh e • • • • ; • Cert # Company Name System Model # Conector Model # 'urea' FEF• . None None " ''" • • DUCTS "'• ••• / -- Supply — — Return -- - - Air CFM 25 • ar', n5 : '..' . •WV#C # V # Location R-Value Area Location Area Leakage Type Handier TOT* • • a OUT ON. RLF HeatCool ...._._..._..... . ._._............... ..... ........ ... _... . ........ ....,..,,. ........................... _.. 1._. ...- Attic 8 315 fe Main 78.6 ft= Prop. Leak Free Main — ckn 41.2 cfm ; B.INS• • 0.50 1 1 TEMPERATURES "" . .. . Programablee jThermosta�t jY CI eiimay ling Fans: (X ri CoolingJan Feb Mar Apr May Jun Oct WNov H Dec Heating t 1 JJanan t J Feb ki MS Oct Maar W+ Pr ar] Jun Jul i Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 ....... _......... _.... .. 6 ._._...... ........... ...... .... 7 8 ..._..... 9 10 11 12 --------- Cooling (WD) .--. .......---- _. . AM 78 PM 80 .................. 78 80 ...... .... --- ......... 78 78 .................. 78 78 78 78 78 78 78 78 78 78 80 78 So 78 80 78 80 78 Cooling (WEH) AM 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 PM 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 riwrrwr■ww. 8141201611:58 AM EnergyGauge® USA - FiaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index, the more efficient the home. 43 NW 110th St., Miami Shores, FL, 33168 1. New construction or existing Addition 9, Wall Types Insulation Area a. Concrete Block - Int Insul, Exterior R=4.1 1392.201t2 2. Single family or multiple family Single-family b. N/A R= ft2 3. Number of units, if multiple family 1 c. WA R= ft2 4. Number of Bedrooms 3(0) d. WA R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1572.00 ft2 6. Conditioned floor area (ft2) 1572 b. N/A R= ft2 c. WA R= ft2 7. Windows" Description Area 11. Ducts R a. U-Factor. Dbl, U=0.65 221.69 ft2 a. Sup: Attic, Ret: Main, AM: Main 8 315 SHGC: SHGC=0.30 b. U-Factor: WA ft2 SHGC: 12. Cooling systems kBtWhr Efficiency c. U-Factor: WA ft2 a. Central Unit . . 42.6' SEER:16.00 .... ...... SHGC: • • • • • • d. U-Factor. WA ft • 13. Heating systems •. • •. • kBiu/#;r .'Efficiency..:. SHGC: a. Electric Strip Heat • • • : • • 24,6 COP: t00 Area Weighted Average Overhang Depth: 1.000 ft. • • • • • • • • • • • • Area Weighted Average SHGC: 0.300 00 8. Floor 7 Insulation Area 14. Hot water systems - Replacer te�q�uipmer; . • galiotra a. Crawlspaae R=13.0 1572.00 ft2 a. Electric ..' • • • : .Cap- ;50 EF: 6.91••• b. WA R= f12 .. • • .. b. Conservation features . .. c. N/A R= ft2 Heat Recovery Unit .... . ...... 15.Credits ••• ••: 00 • 1 certify that this home has complied with the Florida Energy Efficiency Code for Building .-VOE BT.gT Construction through the above energy saving features which will be installed (or exceeded) k _ pa in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. s Builder Signature: Date: '- Address of New Home: City/FL Zip WE 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 814/201611:58 AM EnergyGaugeV USA - FfaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: 43 NW 110th St. Permit Number. Miami Shores, FL, 33168 MANDATORY REQUIREMENTS see individual code sections for full details. 401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and cornett before final approval of the building for occupancy. Florida law [Section 553.9085, Florida Statues) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building. A copy of the EPL display card can be found in Appendix C. V j R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. Q RA02.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402A.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria fisted in Table 402.4.1.1, as applicable to the method of construction. Where required by the code otridal, an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2, and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: ."" 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not seated, bey��ond�ihe� intended wa*&mtnpping.or* other infiltration control measures; • • • • • • • 2. Dampers including exhaust, intake, makeup air, backdrait and flue dampers shall be closed butoW sear blV&d intepft4 ; infiltration control measures; 0 0 0 : 0 0 3. Interior doors, if installed at the time of the test, shall be open; • • • • • • 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed arW sealed• • • • 5. Heating and cooling systems, if installed at the time of the test, shall be turned off, and • • • • • • • • •• 6. Supply and return registers, if installed at the time of the test, shall be fully open. • • • • • • • . "' "00 O R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers and outdoor aon wstion air. . O R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air i;fittratidh rate i jpp jmjgre thar?0.3 t kA per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m;V, wDer; testedeaccording to NFRC 400 or AAMA/WDMA/CSA 101/i.S.21A440 by an accredited, independent laboratory and listed and labeled" the manuffactwer. : • • •: Exception: Site -built windows, skylights and doors. " ' O R402.4A Recessed fighting. Recessed luminaires installed in the building thermal envelope shall be seated to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be iC-rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E 283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. 2 R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. 3 R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.22 Sealing (Mandatory)AII duds, air handlers, and fitter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered duds and plenum chambers, shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post -construction or rough -in testing below. Dud tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99, Florida Statutes, or as authorized by Florida Statutes, to be 'substantially leak free" by either of the following: 1. Post -construction test: Total leakage shall be loss than or equal to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air handier enclosure. All register boots shall be taped or otherwise sealed during the test. Rough4n test: Total leakage shall be less than or equal to 4 cfm (113 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25Pa) across the system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise seam during the test. If the air handier is not installed at the time of the test, total leakage shall be less than or equal to 3 c fn (85 Umin) per 100 square feet (9.29 m2) of conditioned fioor area. Exceptions. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. Dud testing is not mandatory for buildings complying by Section R405 of this code. 814/2016 11:58 AM EnergyGauge® USA - Fialkes2014 - Section R405.4.1 Corn Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) J R403.2.3 Building Cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. I R403.3 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105'F (41'C) or below 55'F (13'C) shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. R403A.1 Circulating hot water systems (Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. RA03.4.3 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/z inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.4.4 Water heater efficiencies (Mandatory). 0 R403.4.4.1 Storage water heater temperature controls • R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100'F to 140'F (38'C to 60'C). • R403.4.4.1.2 Shut down. A separate switch or a dearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supprieg 4t& the main bumer(s) of combustion types of service water heating systems to be turned off. • • 0000 • • • • • • 0 R403AA.2 Water heating equipment Water heating equipment installed in residential units soil ff ggt the mintmurrvefficien of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions,•for the type o1 equipmentinstailed. Equipment used to provide heating functions as part of a combination system shall satisfy all stateVrequifements for Ne appropi�#r Ater heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. . "" • ; 0 • * ; • • Section .... . ..... R403.4A.2.1 Solar wager heating systems. Solar systems for domestic hot water producti p* Lated bitpe apnuai soia*r energy factor of the system. The solar energy factor of a system shall be determined from the Florida 8olar•Energrr Center Directory o Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 99&,'rest Methods {or Solar Cblted(H, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protoc&. C11144ors in installed solar wattle heating systems should meet the following criteria: ' ' • • "'"' 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal' $4d • ; • • • • • ; • "' ; 2. Be installed at an orientation within 45 degrees of true south. • • R403.5 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6 Beating and cooling equipment (Mandatory). The following sections are mandatory for cooling and heating equipment. 0 R403.6.1 Equipment sizing. Heating and cooling equipment shalt be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors which affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load, but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 8/4/2016 11:58 AM EnergyGaugeO USA - FlaRes2014 - Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R403.6.1.1 Coaling equipment capacity. (continued) The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacture's expanded performance data shall be used to select 000ling-only equipment. This selection shall be used to select coolin"rily equipment. This selection shall be based on the outdoor design dry bulb temperature for the load calculation (or entering water temperature for water-souroe equipment), the blower cirri provided by the expanded perfomrance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and mufti -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multi-famity units, the capacity of equipment may be sized in accordance with good design practice. Oj R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the doling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel treating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or treating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment pV#d or controlled to prevent continuous space cooling or heating within that space by one or more of the following options' • • • • • • • • • • • • • 1. A separate cooling or heating system is utilized to provide cling or heating to the mahrAteltainment iomos. • • • . 2. A variable capacity system sized for optimum performance during base load periods is•Ut NW. • • • • • • • • 3 R403.7 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall pompiy with Sections � • • • • C403 and C404 of the Commercial Provisions in lieu of Section R403. • • • • • • • 00006 I R403.8 Snow melt system controls (Mandatory). Snow and ice -melting systems, supplied through ene*,%aNce to t1d Ouilding, shaft • • • include automatic controls capable of shutting off the system when the pavement temperature is above 55"Fo and mo precipitation•is failing• • • • • • and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40`F. • • .. • . . • . . 3 R403.9 Swimming pools, inground spas and portable spas (Mandatory). The energy requirements for resi&ntiai pioofs.artd • • • • • • inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/AP.%P-W.. The energy :0 0 • * 0 requirements for portable spas shall be in accordance with ANSUAPSP-14. • • • . 0000 • ; • • • • .. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on -off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil -fired pool and spa heaters. All gas- and oil -fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot rights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters, pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site -recovered energy, such as a heat pump or solar energy source computed over an operating season. R11404.1 Lighting equipment (Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be higher lamps or a minimum of 75 percent of permanently installed fighting fixtures shall contain only high efficacy lamps. Exception: Low-voftage lighting shall not be required to utilize high -efficacy ramps. O R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights RA05.2 Performance ONLY. AU ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19. Where single assemby of the exposed deck and beam type concrete deck roofs do not have sufficent space. R-10 is allowed. 8/4/2016 11:58 AM EnergyGauge® USA - FiaRes2014 - Section R405.4.1 Com Page 3 of 3 FORM R405-2014 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Carport Enclosure and Remodeling Builder Name: Street: 43 NW 110th St. Permit Office: City, State, Zip: Miami Shores, FL, 33168 Permit Number. Owner. Jurisdiction: 231000 Design Location: FL, Miami COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. a Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceilingisoffit shall be aligned with the insulation and arty gaps in the air barrier shall be sealed. r Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Comers and headers shall be insulated and the junction of the foundation Walls and sill plate shalt be sealed. f V The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in •.. • substantial contact and continuous alignment with the air barrier.. .... . •.... Knee walls shall be sealed. • • • • • • • • • Windows, skylights and doors •••.. •• • The space between window/door jambs and framing and skzigrt%fnd •..... / framing shall be sealed. 0000 ; • • • • ; Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact v4tbli ryderside: '.. ..r... and cantilevered floors) of subfloor decking. 000000 ✓ .' The air barrier shall be installed at any exposed edge of instlatic h.; 0 6 9 99 % Crawl space walls Where provided in lieu of floor insulation, insulation shall be p•ep"a pritly • : • • • • attached to the crawlspace walls. • • • •. �//• Exposed earth in unvented crawl spaces shall be covered with a Class I V vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or tf unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. =� WAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywait. Y Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors !<,i 81412016 11:58 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Carport Enclosure and Remodeling Builder Name: Street: 43 NW 110th St. Permit Office: City, State, Zip: Miami Shores, FL , 33168 Permit Number: Design Location: FL, Miami Jurisdiction: 231000 Cond. Floor Area.: 1572 sq.ft. Cond. Volume: 12911 cu ft. Envelope Leakage Test Results Regression Data: C: 1111111 Single or Multi Point Test Data HOUSE PRESSURE FLOW: _. _.... ............. .. _............ ........_... .. .... ...... Leakage Characteristics CFM(50): ELA: 1 Pa cfm EgLA: ....................... . .... _. - 2 Pa cfm ACH: _..... .-. _ ..._._-. _ 3 Pa cfm ACH(50): } 4 Pa cfm SLA 5 Pa cfm .... . . .... ...... 6 Pa cfm • .... ....... ...... _ .. . . ............ .................... .. .. .. . R402.4.1.2 Testis The building or dwelling unit shall be tested and verified as having an air leakage rate of ; rn 5 air than - i our g �s g �s g rs�.jt� in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a p�essurre of� a . . : inches w.g. (50 Pascals). Where required by time code official, testing shall be conducted by an approved third pat•y .d wsitten napastai the restIts of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed al $4y'time aft4r creation of all ; • • ...... .. . ..... penetrations of the building thermal envelope. . . . . . During 9� testis • • • • • • • • • ..: • 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not seated, beyond the intendedwea lstripping or other • • . • • ...••. infiltration control measures; . • .. • . 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not6a06--yonciintended infitt6Li % control measures; 3. interior doors, if installed at the time of the test, shalt be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5. Heating and cooling systems, if installed at the time of time test, shall be turned off; and 6. Supply and return registers, if installed at the time of the test, shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. SIGNATURE: PRINTED NAME: DATE. Where required by the code official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the third party conducting the test and provided to the code official. BUILDING OFFICIAL: DATE: O*-(HE sr4 8/4/2016 11:58 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 =ORM R405-2014 Duct Leakage Test Report Performance Method FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Form R405 Duct Leakage Test Report Performance Method Project Name: Carport Enclosure and Remodeling Builder Name: Street: 43 NW 110th St. Permit Office: City, State, Zip: Miami Shores, FL, 33168 Permit Number: Design Location: FL, Miami Jurisdiction: 231000 Duct Test Time: Post Construction Duct Leakage Test Results ....... ....................................................................................._....... ........... _._.sees.................... CFM25 Duct Leakage Test Values Line System Outside Duct Leakage 1 System 1 2 System 2 .............. . 3 System 3 4 5 System 4 cfm25(Out) Total House Sum lines 1-4 sees Duct System • • • • Divide by Leakage .. ....... ...... a sees. (Total Conditioned Floor Area) • • • • sees.. . . I certify the tested duct leakage to outside, On, is not greater than the proposed duct leakage On specified on Form R405-2014. SIGNATURE: PRINTED NAME: DATE: Duct tightness shall be verified by F testing to Section 803 of the RESNET Standards by an energy rater certified in i accordance with Section 553.99, Florida Statutes. BUILDING OFFICIAL: DATE: .. ........ _....................... ..... ......... sees sees sees.. sees.. sees eeeeee sees.. sees.. sees. sees. sees.* e e e e ... . sees.. O1THE STq pyNn� .ayw� { f W£`f' 8/4/2016 11:58 AM EnergyGaugeO USA - FlaRes2014 - Section R405.4.1 Compliant S Page 1 of 1 ASHRAE HANDBOOK, 2004 FUNDAMENTALS VOLUME, BUILDING CHAPTER 26 COOLING LOAD CALCULATIONS: Residence at: 43 NW 110th St AREA: 1,572 SQ.FT. Miami Shores, Florida 33168 DATE: 08/04/16 COOLING LOAD CALCULATIONS: SUMMARY PER ACCA MANUAL "J" CONDITIONS: INSULATION: 91 FDB. 79 FWB, OUTSIDE WALLS R-4.1 76 FDB, 5MM RH, INSIDE ROOF R-30 TRANSMISSION: COOLING LOAD, BTUH SENSIBLE LATENT WALLS: Q=AREA'U(TNER. COEFF.)'Tdeq a 1395 X 3.1 4325 Q= 0 x 1.2 0 DOORS: Q= 40 x 8.6 344 ROOF Q= 1572 x 2.1 3301 SOLAR (DOUBLE CLEAR GLASS) GLASS Q= AREA'FACTOR (OSF'SH. COEFF) N Q= 62.1 X 25.938 1611 *000 E Q= 26.2 X 40.657 1085 • • W Q= 52A x 38.961 2042 • • '..' •••• •••••• S Q= 65.5 x 35.894 2417 .. • • • •. • •••••• • •• • •••••• •••• • ••••• INTERNAL HEAT GAIN: • • • • • • • • • • • • • •• •• • •• •••••• PEOPLE Q--*PEOPLE'FACTOR • . • • • • • • ' SEN. 0= 4 x 300 1200 LAT. O= 4 X 230 • �••••• POWER Q=AREA'FACTOR(APPL.) • • • Q= 1572 x 3 4716 TRANSMISSION: QW EOPLE'CFM'T.DIFF 'FACTOR) SEN_ 0= 4 15 15 1.08 972 Q=SPEOPLE`CFM'T.DIFF.'FACTOR) LAT, Q= 4 15 50 0.68 12750 DUCT HEAT GAIN: Q=FACTOR(R-6)'D. LG/ 100 4= 1.4 1200 315 100 sm SENSIBLE TOTAL 27284 LATENT TOTAL 13670 GRAND TOTAL (SEN.+LATENT)= 40954 Manual J: 8tn Edition Residential Heat Loss and Heat Gain Calculations Page 1 ASHRAE HANOBOOC, 2004 FUNDAMENTALS VOLUME, CHAPTER 25 COOLING LOAD CALCULATIONS: HEATING LOAD CALCULATIONS: CONDITIONS: 70FDB, INSIDE 47FDB, OUTSIDE HEATING: TRANSMISSION: Q=AREA'FACTOR(U FACT. -TEMP DIFF.) GLASS: Q= 206 x 29 WALLS: Q= 1395 x 4 ROOF: Q= 1572 x 0.9 VENTILATION: Q=FACTOR'CFM'T.DIFF.IFACTOR (-)INTERNAL HEAT GAIN (L.P.A) HEATING LOAD, KW 5974 5580 1415 SENSIBLE: Q= 1.08 1400 0A 23 - 6US 7022 •••• HUM LOAD i • • • • • • • " Q=FACTOR'SHD'CFM • • • • • • Q= 0.67 10 1400 0.d 3752 • •••••• • DUCT HEAT LOSS •••• • • Q-FACTOR(R-6)'D.LGt100 • • 0000 • • • • • Q= 1.4 900 315 1 1000 397 • • • • • • • • • i •••• •••••• TOTAL �l� 24140 •••••• • OR 7.08 • ' • • .00 BASED ON THE COOLING AND HEATING LOAD CALLS. • • • • 0000 • NEW 3.5 & 5 TONS A/C UNITS 41,500 BTUH TOTAL 130,700 STUH SENS. (1400cfrn) (SEER-16.0) (112.5°%) " • RHEEM RA1642AC1 CONDENSING UNIT AND RHIT4821STAN AIR HANDLER UNIT RHEEM OR EQUIVALENT EQUIPMENT WITH STRIP HEATERS 7.2 KW 3UAN 3. FARACH ARCHFTECTS PLANNERS CELL 305-551-9621 LIC. # 0006930 Manual J: 8th Edition Residential Heat Lass and Heat Gain Calculations Page 2