Loading...
BPP-18-3131U.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008 Federal Emergency Management Agency Expiration Date: November 30, 2018 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION A — PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: Juan Zuluaga A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Company NAIC Number: Box No. 580 NE 106 Street City State ZIP Code Miami Shores Florida 33138 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) MDCR Folio: 11-2231-014-0170 AMD PL Miami Shores Sec 5 PB 10-47 Lot 1&2 BLK 110 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. Latitude/Longitude: Lat. 25.872576° Long.-80.185956° Horizontal Datum: ❑ NAD 1927 ❑x NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1 B A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) N/A sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A8.b N/A sq in d) Engineered flood openings? ❑ Yes Z No A9. For a building with an attached garage: a) Square footage of attached garage 200.00 sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 0 c) Total net area of flood openings in A9.b 0.00 sq in d) Engineered flood openings? ❑ Yes ❑x No SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State Miami Shores 120652 Miami -Dade Florida B4. MapiPanel B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) Number Date Effective/ Zone(s) (Zone AO, use Base Flood Depth) Revised Date 12086CO306 L 09-11-2009 09-11-2009 X N/A B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9: ❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item 139: ❑x NGVD 1929 ❑ NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ❑x No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 1 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November r. 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 580 NE 106 Street City State ZIP Code Company NAIC Number Miami Shores Florida 33138 - SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ❑x Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations - Zones Al-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO. Complete Items C2.a-h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: **MDC Benchmark: D-159 Vertical Datum: NGVD-1929 Indicate elevation datum used for the elevations in items a) through h) below, 0 NGVD 1929 ❑ NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 15.14 ❑x feet ❑ meters b) Top of the next higher floor N/A ❑x feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A feet ❑ meters d) Attached garage (top of slab) 13.22 0 feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building feet 12.47 ❑ ❑ meters (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 12.20 x❑ feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 13.50 ❑x feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including structural support • - - 12.20 ❑x feet • ❑ meters -a - SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? ❑x Yes ❑ No ❑ Check here if attachments. Certifier's Name License Number Juan A. Suarez 6220 Title` Surveyor and Mapper Compan Name Suarez S eying and Ma ping Inc. - ��- Address 15190 SW Stre t #20 City State ZIP Code Miami Florida 33196 Signature Date Telephone Ext. 08-20-2018 (305) 596-1799 Copy all pages of is Elevati Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (includi g type of kquipment and location, per C2(e), if applicable) GPS Coordinates obtained using GPS Device *Miami Dade County Records **Miami Dade County Benchmark C2.E) A/C on Concrete Pad Located on South side of Building Crown of Road Elevation 13.42 FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 580 NE 106 Street City State ZIP Code Company NAIC Number Miami Shores Florida 33138 SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items El—E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,and C. For Items E1—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 3 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2018 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 580 NE 106 Street City State ZIP Code Company NAIC Number Miami Shores Florida 33138 SECTION G — COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8—G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA-issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum G10. Community's design flood elevation: ❑ feet ❑ meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments (including type of equipment and location, per C2(e), if applicable) T ❑ Check here if attachments. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 4 of 6 580 NE 106 Street City State ZIP Code Company NAIC Number Miami Shores Florida 33138 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. fM hYw �� All ry � s r+ Photo One Photo One Caption Front View 08/20/18 Clear Photo One r,� I dy "e ^'t Fa+, s y. 4 ate+ 7l V 4iYY[ p L •t , Yf� j iR�� F y f CAi1 e 4 h 3� 4# Y $ i Photo Two Photo Two Caption Rear view Clear Photo Two FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 5 of 6 580 NE 106 Street City State ZIP Code Company NAIC Number Miami Shores Florida 33138 If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. MW MY i # Ilk 'g vii Y 9 1 II whf Photo Three Photo Three Caption Side view Clear Photo Three �r 7. I A+� t� �Jr• udd r .. i Photo Four Photo Four Caption Side view Clear Photo Four FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 6 of 6 MAP OF BOUNDARY & TOPOGRAPHIC SURVEY 'cD NORTH SCALE: 1 "=20' LOT3 BLOCK 110 19' ASPHALT 70 ter, PAVEMENT 7j �� NE 106th STRE T 9s 0" l � 75' PIW mti^ 1 ri r; M C6 7 N 5' SWK BOB: N 90°OC FIP 112- 10.6 zto (50) r, •; NO ID Lq �'•, N I D/W ry ?� n 1.E 9.69' 23.5' GARAGE = 13.22 oFt no o c0 04 W 9.69' 'D 9.0' 00 CD ?RA Fi `rri 0.10, 2•L •5.0' CO p,'L o ^� zi 16.00' WIRE FENCE IN POOR CONDITION 45.0' ONE STORY CBS RES. # 580 FF = 15.14 +� LOT BLOCK 110 Lu z 29.3' NO ID (52.187 70 _ "O ti APPROXIMATI LOCATION OF SEPTIC TANK DRAIN FIELD (08/20/201E (NOT VISIBLE UNDERGROUN LOT BLOCK 110 16.00' 1 � OUTD00 TUB ; 0.10' ��.� ^� ti 48 on C) 1 + +^ p 10. « a (50' (5, N 89057'43" E 102.16' ``IZI o 0 o 10' ASPHALT o 10 PAVEMENT IFALLEY 7� L=39.30' -- R=25.00' 0=90°04'40" I4 00191 O� N:. ,7 So v 23.98' rr co 70, # . r _ _ 23.98' "�S o m � AND SEP C TANK Ot 7.0' rn oVDRA EID �-M Q . Imo. CD N : d' lO 0 :C) I� 6.0' . AS 7L? 35.00' 7s LEGEND ABBREVIATIONS: A =ARC DISTANCE A/C = AIR CONDITIONER PAD AE ACCESS EASEMENT CDi11FlCATE OF AUTHORIZATION # LB-7104 = BLDG= BUILDING suarez Surveying 8c mapping, IrlCa BM =BENCHMARK 15190 SW 136th Street, Suite 20, Miami, Florida 33196 BOB =BASIS OF BEARINGS CBS = CONCRETE BLOCK & STUCCO Tel: 305.596.1799 Fax: 305.596.1886 (C)=CALCULATED www.suarersurveying.com C = CHORD CB = CATCH BASIN PLAT IMAGE: CHB = CHORD BEARING C&G = CURB & GUTTER NOT TO SCALE CLF = CHAIN LINK FENCE COIL =COLUMN CONE = CONCRETE DE =DRAINAGE EASEMENT DME= DRAINAGE & MAINTENANCE EASEMENT "1 •' IS''4'k� E'.F t 1 -::1 •„(„• j �����'+� D/W = DRIVE -WAY 10 61—H a'T R E E -r ' EAS. = EASEMENT ENC. = ENCROACHMENT EW = EDGE OF WATER L 3 2 t FDH = FOUND DRILL HOLE FF =FINISHED FLOOR ELEVATION _ FIP = FOUND IRON PIPE - FIR = FOUND IRON ROD FN = FOUND NAIL (NO ID) :I 22 23 ?1W e l3 'IV IS %& �"j tts iQ Z021 ;2 23 24 FND = FOUND NAIL & DISK d FPL = FLORIDA POWER & LIGHT TRANSFORMER PAD sd r7 IMFSGE = INSTALLATION AND MAINTENANCE OF FIRE HYDRANTS, .D STREET LIGHTS AND GUARD RAILS EASEMENT (M) = MEASURED .. Lo• sn .. .. .. .. .- .. x ,. MDCR=MIAMI-DADE COUNTY RECORDS MH =MAN HOLE ML = MONUMENT LINE 111 O/S = OFF-SET----y'---r-7 1/•� • >Si '� (P) = PLAT 1 ! ?:1 " 7 n • i • • • •1 PS = PLAT BOOK PROPERTY ADDRESS: • • PC =POINT OF CURVATURE • 0000 ) • • PCP = PERMANENT CONTROL POINT 580 NE 106TH STREET, MIAMI SHORcA FYORIDA 33139 • • • • • • • • � • PE = POOL EQUIPMENT PAD LEGAL DESCRIPTION: ... ; . • PG =PAGE PI =POINT OF INTERSECTION LOTS 1 AND 2, BLOCK 110, MIAMI SHORES SECTION 5 AMENDED, ACCQfjjlj j PK = PARKER KAELON (SURVEY NAIL) THE PLAT THEREOF, AS RECORDED. It "A%BOOK 18,• PAS O 47, OF 1bIE PUBLIC PL = PLANTER RECORDS OF MIAMI-DADE COUNTY, FROIHIDI,. • • • • • • POB = POINT OF BEGINNING FLOOD ZONE INFORMATIQ4(4 e e e • POC = POINT OF COMMENCEMENT • • • • PRC = POINT OF REVERSE CURVATURE BASED ON THE FLOOD INSURANCE • VATS • MAP Ore THE FEDERAL EIt6RCY 09 FIRM = PERMANENT REFERENCE MONUMENT MANAGEMENT AGENCY REVISED ON /117OTJ AND INDEX•ttA* WREMSED ON 400/619'09 PT =POINT OF TANGENCY THE GRAPHICALLY DEPICTED BUILDIND"eNOWN ON THIS MOP OF SURVEY IS JITHIN R = RADIUS DISTANCE ZONE & BASE FLOOD ELEVATION NIA CUONITY NVE & NUMBER MIAMI SHORES (R) = RECORD 120662 MAP & PANEL NUMBER 12086CO306 SUFFIX L a • • • e • • • • • R/W = RIGHT OF WAY • RES. = RESIDENCE SURVEYOR'S NOTES: 0 e • e • • • SIP = SET IRON PIPE 1. ELEVATIONS WHEN SHOWN REFER ArO 1928 NATIONA10 6EOpETIC VER4IIL• t!� SND = SET NAIL & DISK (PK) (NGVD 1929). e e • STL=SURVEY TIE LINE 2. NO ATTEMPT WAS MADE TO LOCATE FOOTINGS/FOU"TIONS, OR UNDERGROUND SWK=SIDEWALK UTILITIES UNLESS OTHERWISE NOTED. (TYP)=TYPICAL 3. THE LANDS SHOWN HEREON HAVE NOT BEEN ABSTRACTED IN REGARDS TO UB = UTILITY BOX MATTERS OF INTEREST BY OTHER PARTIES, SUCH AS EASEMENTS, RIGHTS OF WAYS, UE = UTILITY EASEMENT RESERVATIONS, ETC. ONLY PLATTED EASEMENTS ARE SHOWN. W/F = WOOD FENCE 4. THIS SURVEY WAS PREPARED FOR AND CERTIFIED TO THE PARTY(IES) INDICATED WME = WALL MAINTENANCE EASEMENT HEREON AND IS NOT TRANSFERABLE OR ASSIGNABLE. SYMBOLS: 6. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE = CENTER LINE ®= ELECTRIC BOX SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES Wv © =CABLE TV RISER 6. IMPROVEMENTS SHOWN HAVE BEEN MEASURED TO THE NEAREST LOTH OF A FOOT. = WATER VALVE ® = WATER METER TIES SHOWN HAVE BEEN MEASURED TO THE NEAREST 100TH OF A FOOT. CURB INLET X 0.00 = ELEVATION ELEVATIONS WHEN SHOWN HAVE BEEN MEASURED TO NEAREST 100TH OF A FOOT ON (00') = ORIGINAL LOT DISTANCE HARD SURFACES AND NEAREST TENTH OF A FOOT FOR GROUND OR SOD SURFACES = FIRE HYDRANT A = CENTRAL ANGLE 7• ALL BOUNDARY LIMIT INDICATORS SET ARE STAMPED LB# 7104. =UTILITY POLE 8. THE BOUNDARY UMITS ESTABLISHED ON THIS SURVEY ARE BASED ON THE LEGAL c0jDESCRIPTION PROVIDED BY CLIENT OR ITS REPRESENTATIVE. = METAL LIGHT POLE = DRAINAGE MANHOLE 9. FENCE OWNERSHIP NOT DETERMINED. ® CATCH BASIN S =SEWER MANHOLE 10. BEARINGS WHEN SHOWN ARE TO AN ASSUMED MERIDIAN, THE NORTH LINE OF = O LOTS 1 AND 2 HAVE BEEN ASSIGNED A BEARING OF N 90'00'00' E 0 = WIRE FENCE OO = ENCROACHMENT # 11. TYPE OF SURVEY: BOUNDARY & TOPOGRAPHIC. --x--x— = WOOD FENCE ® = CONC. POLE BENCHMARK REFERENCE: —)(—l(-- = CHAIN LINK FENCE NAME: D-159 • = OVERHEAD UTILITY WIRE ELEV(NGVD29): 10.32 SURFACES: LOCATTONI: NE 105 ST --- 69' SOUTH OF CA 4 ' EAST OF CA InOF THEPNTERSECTION8RASS WASHER IN CONE. CATCH BASIN AT SE CORNER ASPHALT CO CRET: PAVERS BUILDING LLLLLL CERTIFIED TO: LLLLLL JUAN ZULUAGA LLLL LLLL LLLL TILES OOD COVER E SURVEYOR'S CERTIFICATE. I AND I HEREBY CERTIFY THAT THIS SURVEY IS TRUE AND CORRECT TO THE BES OF YJND DATE OF SURREY .` BELIEF AS RECENTLY SURVEYED AND DRAWN UNDER MY DIRECTION AND E THOF /0812012018 PRACTICE SET FORTH BY THE FLORIDA STATE BOARD OF SURVEYORS AN M PPERR 5J-17 •�#, 180827699 FLORIDA ADMINISTRATIVE CODE PURSUANT TO SECTION 472.027 FLORID S TUE. FILE * C-19749 _ AUTHENTIC COPIES OF THIS SEAL PROJECT NAME.` SURVEY SHALL BEAR THE SURVEYS 2018 ORIGINAL SIGNATURE AND CAD FILE(M): ZULUAGA RAISED SEAL OF THE JUAN A. SUAREZ ATTESTING REGISTERED PR FESSIONAL SURVEYOR 8 PIPER PARTY CHIEF.- LAZARO SURVEYOR AND MAPPER STATE OF FLORIDA LIC. # 6220 SHEET 1 OF 1