Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-19-36
Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 01/10/2019 Location Address Parcel Number 55 NW 102ND ST, Miami Shores, FL 33150 1131010180090 Contacts Permit NO.: RF-01 Permit Type. Roof Work Classification Tile Permit Status: Approved` Expiration: 07/08/2019 MARTA ARFELD Owner TOP SEAL SERVICES CORP Contractor 55 NW 102 ST, MIAMI SHORES, FL 331501229 RONALD MEDINA Business: 3057547844 Description: RE -ROOF TILE ROOF TO COLOR THRU TILE Valuation: $ 17,000.00 Inspection Requests: Total Sq Feet: 2,800.00 Fees Amount Application Fee - Other $50.00 CCF $10.20 DBPR Fee $4.50 DCA Fee $3.00 Education Surcharge $3.40 Roofing Fee $250.00 Scanning Fee $9.00 Technology Fee $7.50 Total: $337.60 Building Department Copy Payments Date Paid Amt Paid Total Fees $337.60 Check # 5624 01/10/2019 $337.60 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws r tip construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. Signature: Owner / Applicant / Contractor / Agent Date January 10, 2019 Page 2 of 2 BUILDING PERMIT APPLICATION Miami Shores Village RECEIVED Building Department JAN082019 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FB�2O Master Permit No. 2 E Sub Permit N ❑ BUILDING ❑ ELECTRIC W ROOFING ❑ REVISION ❑ EXTENSION ❑ RENEWAL ❑PLUMBING ❑ MECHANICAL [:]PUBLICWORKS [:]CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: _ S S /y • 0 ` / © a S7- City: Miami Shores County: Miami Dade Zip' --5 7 S U Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Ili I+'C I /V y1j ))- Phone#:7 Address: SS- IV, r 0 S City: State: Zip: Tenant/Lessee Name: Phone#: Email: ✓YI fa 2 i !4 4 04 I�00. G' 0 CONTRACTOR: Company Name: 1 t c n,( � C"{S Phone#: (3)a 96 3 Z'7 Q Address: > R-k.Si% City: r—%kCSP�—NLC State: Zip:��2� —1 Qualifier Name: -� � Cl�---� Phone#: 4\3 2! 4(' b State Certification or Registration M CC C c3 `30 k t_1 Certificate of Competency #: . DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ / oyz, Square/Linear Footage of Work: Af d o Type of Work: ❑ Addition ❑ Alteration ® New ❑ Repair/Replace ❑ Demolition Description of Work: cam~ Specify color of co/or'th'ru #ile:' rl� .y Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ (Revised02/24/2014) Bond $ TOTAL FEE NOW DUE $ J� Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In t a71e' o such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signatu OWNER or AGENT The foregoing instrument was acknowledged before me this 7 day of r 20 J q by who is per ona lye kn n to me or who has produced as identification and who did take an oath. 4Print: C: MAVi RAl K. GONLAL �"'�►.' GG 04400x Seal' '?* EXPIRES: November 2, 2 k"; Pub11c Und�rwrlt•n NotaN 9- APPROVED BY The foregoing instrument was acknowledged before me this 2 day of a 20 t q by PCW- 3e- �—jcEwho is ersonally known o me or who has produced as identification and who did tak o NOTARY PUBLIC: Print: Seal: Plans Examiner Structural Review Zoning Clerk (Revised02/24/2014) 1/8/2019 Property Search Application - Miami -Dade County OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3101-018-0090 Property Address: 55 NW 102 ST Miami Shores, FL 33150-1229 Owner MARTA ARFELD LE REM MARTA ARFLED TRS MARTA ARFELD LIVING TRUST Mailing Address 55 NW 102 ST MIAMI SHORES, FL 33150 USA PA Primary Zone 0800 SGL FAMILY - 1701-1900 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/2/0 Floors 1 Living Units 1 Actual Area 2,504 Sq.Ft Living Area 2,171 Sq.Ft Adjusted Area 2,332 Sq.Ft Lot Size 9,180 Sq.Ft Year Built 1947 Assessment Information Year 2018 2017 2016 Land Value $202,184 $202,184 $202,184 Building Value $174,900 $162,307 $162,307 XF Value $1,999 $1,999 $1,999 Market Value 1 $379,083 $366,490 $366,490 Assessed Value 1 $177,861 $174,203 $170,620 Benefits Information Benefit Type 2018 2017 2016 Save Our Homes Cap Assessment Reduction $201,222 $192,287 $195,870 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,0001 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description NAVARRO SUB PB 12-59 E35FT LOT 18 & ALL LOT 19 BLK 1 LOT SIZE IRREGULAR OR 16919-3060 0995 1 Generated On : 1/8/2019 Taxable Value Information 2018 2017 2016 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $127,861 $124,203 $120,620 School Board Exemption Value $25'000 $25,000 $25,000 Taxable Value $152,861 $149,203 $145,620 City Exemption Value $50,000 $50,000 $50,000 Taxable Value $127,861 $124,203 $120,620 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $127,861 $124,203 $120,620 Sales Information Previous Price OR Book- Qualification Description Sale Page 11/17/2014 $100 29493-0152 Corrective, tax or QCD; min consideration 09/01/1995 $125,600 16919-3060 Sales which are qualified 08/01/1993 $112,500 16048-3152 1 Sales which are qualified 07/01/1991 1 $65,000 15095-1207 1 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamid ad a.gov/info/disclaimer.asp Version Miami Zillhores Village 9 Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: _ 44", 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: G �t5 Property Address:_ 5 S' I/, 1C% / r> Roofing Permit Number: Dear Building Official: I certify that I am not required to retrofit the roof to wall connections of my building because: 4 ;Ae just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. c The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) . ...... .... Si nature State of Florida County of Dade ^4 i2T4 4--k i- c 2 Print Name The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this .%day of Notary Public, Sate of Florida at MAHARAI K. GONZALEZ MY COMMISSION # GG 044602 EXPIRES: November 2, 2020 nded Thru Notary Public Underwriters When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 1/7/2019 Property Search Application - Miami -Dade County f Non -Ad Valorem Assessments Property Record Cards Property Taxes Report Homestead Fraud Tax Estimator Value Adjustment Board ASSESSMENT INFORMATION Year Land Value Building Value Extra Feature Value Market Value Assessed Value 4 TAXABLE VALUE INFORMATION COUNTY Exemption Value Taxable Value SCHOOL BOARD Exemption Value Taxable Value CITY Exemption Value Taxable Value REGIONAL Exemption Value Taxable Value BENEFITS INFORMATION Benefit Save Our Homes Cap Homestead PA Additional Online Tools Property Search Help Report Discrepancies Tax Comparison TRIM Notice 2018 2017 2016 $202,184 $202,184 $202,184 ,$174,900 - $162,307 $162507 $1,999 $1,999 $1,999 $379,083 $366,490 $366,490 $177,861 $174,203 $170,620 2018 2017 2016 $50,000 $50,000 $50,000 $127,861 $124,203 $120,620 $25,000 $25,000 $25,000 $152,861 $149,203 $145,620 $50,000 $50,000 $50,000 $127,861 $124,203 $120,620 $50,000 $50,000 $50,000 $127,861 $124,203 $120,620 Type 2018 2017 2016 Assessment Reduction $201,222 $192,287 $195,870 Exemption $25,000 $25,000 $25,000 1 /7/2019 Property Search Application - Miami -Dade County The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.govfiinfo/disclaimer.asp For inquiries and suggestions email us at http://www.miamidade.gov/PAPortal/ContactForm/ContactFormMain.aspx. Version: 2.0.3 EXEMPTIONS 5 BENEFITS Deployed Military Disability Exemptions Homestead Institutional Senior Citizens REAL ESTATE 40 Yr Building Re -Certification Appealing Your Assessment Defective Drywall Folio Numbers Mortgage Fraud TANGIBLE PERSONAL PROPERTY Appealing your Assessment Assessment Information Search https://www.miamidade.gov/propertysearch/#/ More > More > 6/8 ,_ �,. , M IAM I•NibE °Delivrring Excellence Every Day" ------ MIAMI-DADE COUNTY ------ REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS It is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this form. The owner's initials in the designated space indicates that the item has been explained. 1. Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be re ailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be vieTk from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Owner's/Agent's Signat e: Date: Contractor's Signature: Permit Number: Property Address: 5 s Al -6t) • /e'-� Sz-. 1i' OWNER'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. To: Miami -Dade County Building & Neighborhood Compliance Department 11805 Coral Way, Suite I I I Miami, FL 33175 Re: Owner's Name R2 4k l 4 }-c 4b Property Address Roofing Permit Number Dear Building Official: I PA -Wti- ►- cQ -P� , certify that I am not required to retrofit the roof to wall connections of my building because: KA LOJ The just valuation for the structure for purposes of ad valorem taxation in less than $300,000.00. UThe building was constructed n compliance with the provisions of the Florida Building Code (FBC) or with the provisions of the 1994 edition of the South Florida Building Code (1994 SFBC). " Al-� �o Signature of Property dwner Print Name STATE OF FLORIDA COUNTY OF MIAMI-DADE Sworn to and subs c ibed before me this day of , 20 iQ , (SEAL) Personally known or Produced Identification 0z0z'n ^QZ0043t8R3 23Nllatlw 13VHOIIN When the just valuation of the structure for purposes of ad valorem taxation is equal to or more than $300,000.00, and the building was nez constructed in compliance with the FBC nor with 1994 SFBC, and affidavit of Roof to Wall Connection Hurricane Mitigation Retrofit must be provided. 1 /7/2019 Property Search Application - Miami -Dade County Building Sketches Available! EXTRA FEATURES Description Chain4ink Fence 4-5 ft high Patio - Concrete Slab I ADDITIONAL INFORMATION Year Built Units Calc Value 1947 130 $715 1947 535 $1,284 ' The information listed below is not derived from the Property Appraiser's Office records. It is provided for convenience and is derived from other government agencies. LAND USE AND RESTRICTIONS Community Development District: NONE Community Redevelopment Area: NONE Empowerment Zone: NONE Enterprise Zone: NONE Urban Development: INSIDE URBAN DEVELOPMENT BOUNDARY Zoning Code: R15 - Existing Land Use: Temporarily Unavailable M Government Agencies and Community Services OTHER GOVERNMENTAL JURISDICTIONS Business Incentives Childrens Trust City of Miami Shores Environmental Considerations Florida Department Of Revenue Florida Inland Navigation District PA Bulletin Board Non -Ad Valorem Assessments School Board South Florida Water Mgmt District Tax Collector https:Uwww.miamidade.gov/propertysearch/#/ 5/8 1/7/2019 Exemptions Extension Requests Filing Returns PUBLIC RECORDS Address Blocking Change of Name Change of Address Change of Ownership & Title Declaration of Condominium ONLINE TOOLS Property Search Property Sales Tax Estimator Tax Comparison Homestead Exemption and Portability TAX ROLL ADMINISTRATION Property Search Application - Miami -Dade County More > More > More > https://www.miamidade.gov/properrysearch/"#/ 7/s 1/7/2019 Property Search Application - Miami -Dade County Sedond Homestead Exemption $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). FULL LEGAL DESCRIPTION NAVARRO SUB PB 12-59 E35FT LOT 18 & ALL LOT 19 BLK 1 LOT SIZE IRREGULAR OR 16919-3060 0995 1 SALES INFORMATION $25,000 $25,000 Previous Sale Price OR Book -Page Qualification Description 11/17/2014 $100 29493-0152 Corrective, tax or QCD; min consideration 09/01/1995 $125,600 16919-3060 Sales which are qualified 08/01/1993 $112,500 16048-3152 Sales which are qualified 07/01/1991 $65,000 15095-1207 Sales which are qualified 06/01/1991 $0 15095-1206 Sales which are disqualified as a result of examination of the deed 01 /01/1991 $0 14873-2749 Sales which are disqualified as a result of examination of the deed 08/01/1979 $77,000 10502-1146 Sales which are qualified 04/01/1979 $70,000 10371-1585 Sales which are qualified 08/01/1974 $52,500 00000-00000 Sales which are qualified For more information about the Department of Revenue's Sales Qualification Codes. 2018 2017 2016 LAND INFORMATION Land Use Muni Zone GENERAL R-14.25, R-15 GENERAL R-14.25, R-15 4 BUILDING INFORMATION Building Number Sub Area 1 1 Previous Owner 1 MARTA ARFELD PA Zone Unit Type Units Calc Value 0800 - SGL FAMILY - 1701-1900 SQ Front Ft. 75.00 $178,398 0800 - SGL FAMILY - 1701-1900 SQ Front Ft. 10.00 $23,786 Year Built Actual Sq.Ft. Living Sq.Ft. Adj Sq.Ft. Calc Value 1947 2,504 2,171 2,332 $174,900 https://www.miamidade.gov/propertysearch/#/ 4/8 1/7/2019 Property Search Application - Miami -Dade County Appealing your Assessment Reports More > hops://www.miamidade.gov/propertysearch/#/ 8/8 Florida Building Code Edition 2010 H1 hMOMi Hawn Zone Unftm Pend AR&ation Form. • �P o� Sectlon A (General Information) %vA*aster Permit No. piss No, ` : Contragtoee Name Job Address oL ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ /asphaltic CI Metal PanellShtngles gjjd�Ad ShinglestB�akes • • • • • C Shingles ❑ prescriptive.... SUR-RAS'i50 ROOF TYPE •�•• •••• ❑ New Roof ❑ Reroofing ❑ Recovering ❑ Repair ❑ iglM lance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) , V Section`8 (Roof Plan) Sketch Roof Plan: illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly iden dimensions of elevated pressure tones and location of parapdts. LLI • .ill LwL , ?� ...' - - ....! .. _ +l , Q _ f z Z ,. J. Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof Systgnj Roof -System Manufacturer:_,_____j��r�� Tv1C.. S ., Notice of Acceptance Number: ) g"- og zq• 01 Minimum Design Wind Pressures, If Applicable (From RAS 127 or UalcLIatioAs): P1: 3.62 P2: 12.01 P3: 21.43 Maximum Design Pressure From the NOA Specific S stem :_°. • 0 • • • • • • .. • .. • • Method of the attachment:_ I C P AH-160 One L Iti*' zit < C��► � � .. Steep Sloped Roof System Description Deck Typ Roof Slope: — 4 .12 R1dge Ventilation? N/A Plywood 5/8 nderlayment• Mean Roof Height: 13 30# ASTM D226 Type I N/A Sarinen NIA astener Type & Spacing: 1 1 1 /4" RS Coil & 1 5/8" TC "I Self -Adhered Cap sheet: --- Polyglass TU oaf Covering: Plantation Type & Size Drip dge: 3x3 26 ga Gafv. 0 Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based the systems, choose efther Method 1 or 2. Compared the values for Mrwfth the values from Mt. N the Mt values are greater than or equal to the Mr values, for each area of the roof, then the tale attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" •... (PI.- 39.1 z j . 8Z 9 i0 11.29 1 —Mg: 7,67 -Mr, a-6_ NOA INt. `lf iC P "160 (Pl: 68.1 z .289 a _ 1268 ) _'Mg: 7.67 .. Mi12 01 NOA b'1t .f %. ••i'1 �y c. (103: 100.7 z 289 = 29.10 1 _ Mg: 7.67 -11tr 2. 1.43 NOA K L.��i� � • j) •,J3`�°�� Meibod 2 "Sflnpunm Tile Calculation Per Table Below" .... Required Moment of Resistance (M,) From Table Below NOA bf, %t e o •• Mr Required Moment Resistance• • • • • Mean RW Height Root elope 15' 2W 25, W • 364 Z .7.o It 1 s a so 32A V. .o *Must be used in conjunction with a list of moment based tale systems endorsed by the Broward Ccuuty Board of Rules and Appeals. For Uplift based file systems use Method 3. Compared the values for F' with the values for Fr If the Fr values are greater than or equal to the Fr values, for each area -of the roof, then the the attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" ---I w: - ---3 — w: — z cos 6. —= Fri: — NOA F' w: _ _.__.j — W , z cos e = Fn: — NOA F' (Ps:—zl:_,,,_m— = w:--)—W—zcosB:—= Fri_ NOA F' Where to Obtain Information DesCri on S bol Where to find Ded9nPtcasonc Fl arF2orM RAS 127Tabb l ofbyaaea iD9ao }ysisF;F ttdby FFb-3wdonASCE 9 bk&oRwfKdWt H Job Site RooMme 6 Job Site NOA Mgt dome to NOA Red.tance Mr NOA cvlsted Maim= NOA Rct11f Calmbftd Avers eTtle WW NOA T Dimenm= N A W- WkkII All aknlatians moat atbmiSed m theding Offidd at Ste time of lieatton • i„IIA,=pE MIAMI-DADE COUNTY M I PRODUCT CONTROL SECTION • 11805 SW 26 Strti et, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidadL.gov/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: •••• This NOA is being issued under the applicable rules and regulations governing the use of constlpJan matt rials The • • �: • documentation submitted has been reviewed and accepted by Miami -Dade County RER-ProdujL�.Opirol Seoti'v4rbe used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdictiop,(m- , • This NOA shall not be valid after the expiration date stated below. The Miami -Dade County $milt UControf StNon • (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve IV right to 11aWthis product or material tested for quality assurance purposes. If this product or material fails to;ertorni in tha aceaeopted manner, the manufacturer will incur the expense of such testing and the AHJ may immediatglX*�voke, modify, or •••�: suspend the use of such product or material within their jurisdiction. RER reserves the right tctreveki, this aicepgrice, if it is determined by Miami -Dade County Product Control Section that this product or tn3teriaj, fails tQ ttfL'Ci the • requirements of the applicable building code. 9.6 • oe • • • • •.. This product is approved as described herein, and has been designed to comply with the Florida Buil!? •Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Plantation Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or -logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #15-0721.04 and consists of pages i through 7. The submitted documentation was reviewed by Freddy Semino C wDADECOUNTr NOA No.: 18-0829.02 ' 3 Expiration Date: 12/08/20 Approval Date: 10/I1/18 Page I of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Boral Plantation Concrete Roof Tile, as manufactured by Boral Roofing, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with th%Flarida Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requiremants, as d'ew"n*ed ...... by applicable Building Code, do not exceed the design pressure values. obtain by calculations in-ocmp iance+xith RAS .' 127 using the values listed in section 4 herein. The attachment calculations shall be prepaeedas a monientVased ....:. system. 0 ... . .... .... . . • PRODUCT DESCRIPTION .... .... """ • • ..... • • • • • Manufactured by Dimensions .. .. .. . Test fte f act ...... .' Applicant — Speccations DliscrinAon • • • •• • • Plantation Tile Length: 16'/3" TAS 112 Flat concrete rodf.tlle f;r direit deck or � • • • • Width: 13" battened nail -on, mortar or adtTg4 *;set applications. Trim Pieces L = varies TAS 112 Accessory trim, concrete roof pieces for W = varies use at hips, rakes, ridges and valley Varying thickness terminations. Manufactured for each tile profile. 2.1• MANUFACTURING LOCATION 1. Okeechobee, FL 2.2 PRODUCTS MANUFACTURED BY OTHERS Product Name Product Description ICP Adhesives Polysete AH-160 Two component polyurethane foam adhesive. TILE BONDT" Roof Tile Adhesive Single component polyurethane foam roof the adhesive. DAP Foam Touch N Seal StormB=02 Roof Tile Adhesive MIAMFDgpE CpUNTYIN Two component polyurethane foam adhesive. Manufacturer (With Current NOA1 ICP Adhesives and Sealants, Inc. The Dow Chemical Company Dap Foam, Inc. NOA No.: 18-0829,02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 2 of 7 2.3 SUBMITTED EVIDENCE: Test Agency Test Identifier American Test Lab of South RT0624.05-14 Florida Redland Technologies The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Farabaugh Engineering and Testing Inc. Farabaugh Engineering and Testing Inc. Farabaugh Engineering and Testing Inc. PRI Construction Material Technologies 3. UMITATIONS 7161-03 Appendix III 94-060B 94-084 7161-03 Appendix II Letter Dated Aug. 1, 1994 P0631-01 P0402 Project No. 307025 Test 4MDC-76 Calculations Test Name/Report TAS 112 Static Uplift Testing PA 102 & PA 102(A) Static Uplift Testing PA 101 (Adhesive Set) (Mortar Set) Wind Tunnel Testing. • PA 108 (Nail -On) 0..* Wind Tunnel Testing., • • • • PA 108 (Nail -On) Wind Tunnel Testing .... Withdrawal Resistance Ts*ie o€. screw vs. smooth shank nvils• • 0 Wind Driven Rain PA 100 • Aerodynamic Multi pligr Calculations 25-7183 25-7094 25-7496 Calculations 25-7584 25-7804b-8 25-7804-4 & 5 25-7848-6 Calculations Two Patty Adhesive Set System T295-11 TAS-108 T306-1.1 T279-11 DAPF-004-02-08 DAPF-004-02-09 DAPF-004-02- l 0 TAS-108 TAS-109 TAS 101 Static Uplift Resistance Adhesive Set Date 07/03/14 Dec. 1991 March, 1994 May 1994 Dec. •1�3�i AQ�.•149�4 Julya994 Sejt,.1993 . . •• • Oct. 1,994 • • . • • • March 1999 April'19g9 Mai'ch'1r395 February 1996 April 1996 December 1996 April 1999 10/05/11 10/04/11 09/23/11 07/26/18 07/26/18 07/26/18 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set the applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control office for review. MIAMIOADE C DLRM7= NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 3 of 7 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code, 4. INSTALLATION �....' 4.1 Plantation Roof Tile and its components shall be instal led in strict compliance with RAofing 4ppli tion Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations .... .... Table 1: Average Weight (W) and Dimensions (I x w) • • • • • • 000000 Tile Profile Weight-W (Ibf) Length-1 (ft) ..o:ljdth-w (*ft Plantation Tile 11.6 1.375 • • 1.08• • Table 2: Aerodynamic Multipliers - X (ft3) • Tile X (ft3) X (ft3) Profile Batten Application Direct Deck Application Plantation Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity - M (ft.-Ibf) Tile - i Greater than Profile 2": 12" 3": 12" 4": 12" 5": 12" 1 6` 12" 7": 12" Battens Direct Battens I Direct Battens Direct Battens Direct I Battens Direct Battens Direct Deck Deck Deck Deck I Deck Deck Plantation 7.22 7.91 6.85 7.79 6.75 6.61 7.52 6.44 7.32 6.26 7.04 Tile T7,67 1 I M1AMMADECONOA No.: 18-0829.02 liliestmllrjf NNW Expiration Date: 12/08/20 Approval Date: 10/11/I8 Page 4 of 7 ...00 Table 4: Attachment Resistance Expressed as a Moment - MI (ft-Ibf) For Nall -On Systems Tile Profile Fastener Type Direct Deck (Min 15/32" Direct Deck (Min. 19/321, Battens plywood) plywood) Plantation Tile 2-10d Ring Shank 30.9 38.1 17.2 Nails 1-10d Smooth or 7.3 9.8 ( 4.9 Screw Shank Nail 2-10d Smooth or 14.0 18.8 . 7A ...• Screw Shank Nails • 1 #8 Screw 30.8 30.8 • • • • 18. ' 2 #8 Screw 51.7 51.7 • • • • 24, 4 1-10d Smooth or Screw Shank Nail 24.3 24.3 •••. 24.2--% • • • • •.. I Field Clip)• • • • • • • 1-10d Smooth or 19.0 19.0 22.1'�' Screw Shank Nail Eave Clip)' •�••�• ! • 2-10d Smooth or Screw Shank Nails 35.5 35.5 • i•• 3j.8 �• Field Cli 2-10d Smooth or 31.9 31.9 32.2 Screw Shank Nails Eave Clip) 2-10d Ring Shank 50.3 65.5 48.3 Nails' 1 Installation with a 4" the headlap and fasteners are located a minimum of 2%"from the head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) For Two Patty Adhesive Set -Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Adhesive2 2 See manufactures component approval for installation requirements. 3 The Dow Chemical Co. TILE BONDTm Roof Tile Adhesive weight per patty 119 rams. 31.3 4 ICP Adhesive and Sealants, Inc. ICP Adhesve Pal set® AH-160 Two -Component weight per patty 8 grams. 31.3 5 DAP Foam Touch N Seal Storm6ond® 2 Roof Tile Adhesive weight per paddy 8 grams. 45 MIAMI.DADECOLWTY NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 5 of 7 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft4bf) For Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Adhesives 6 See manufactures component approval for installation re uirements. 7 ICP Adhesive and Sealants, Inc. ICP Adhesve Pol set(D AH-160 Two -Component weight per patty 45 grams. 118.9 8 ICP Adhesive and Sealants, Inc. ICP Adhesve Pol set® AH-160 Two -Component weight per patty 24 grams 40.4 9 DAP Foam Touch N Seal StormBondo 2 Roof Tile Adhesive weight per paddy 45 grams. 73 10 DAP Foam Touch N Seal Storrn6ondO 2 Roof Tile Adhesive weight per paddy 24 grams f f f • ••f• Table 7: Attachment Resistance Expressed as a Moment - Mf (ft•ibf} for Mortar Set Systems • • • • • • • Tile Profile Tile Application 'AWChment • .Weistance•••• See specific mortar manufacturer's Notice of Acceptance .90 •'•' �fT • • • • • • • • 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo asse111ri b;)ow op following statement: "Miami -Dade County Product Control Approved". •••••• OR BORAL PLANTATION ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. MIAMPDAo�� NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/I1/]8 Page 6 of 7 PROFILE DRAWING BORAL PLANTATION FLAT CONCRETE TILE .•.• • .... •••... • • •• • • .. ....♦ 00 0 00*0:0 • •.•••. • • • •. . • END OF THIS ACCEPTANCE MIAMM ApECourrrr NOA No.: 18-0829.02 ' Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 7 of 7 M�IAM�I•DiADE �'L'1►tN MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Polyglass USA Inc. 1111 W. Newport Center Drive Deerfield Beach, FL 33442 .... . . .... ...... SCOPE: • ...... . ...... This NOA is being issued under the applicable rules and regulations governing the use of con st: � �tion materials. The • documentation submitted has been reviewed and accepted by Miami -Dade County RER - PrQdtjcrt Control $ration to:V • •; used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdkk"(AHJ).•....• ..... ...... .. . ..... This NOA shall not be valid after the expiration date stated below. The Miami -Dade County.Modtict Co'h:sdl.Section..... (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve 41wrigfit to have this • • product or material tested for quality assurance purposes. If this product or material fails to perfortn in tte itgepted • • • • • manner, the manufacturer will incur the expense of such testing and the AHJ may immediaZly c&oke, rhodify, or :....: suspend the use of such product or material within their jurisdiction. RER reserves the right1to revoke t;is•ftcceptance, • if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Semino. to MIAMFDADE COUNTY NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 1 of 8 ROOFING COMPONENT APPROVAL Catezorv: Roofing Sub-Cateeory: Underlayment Material: SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Test Product Product Dimensions •••• Specification Descrjptiop • Polystick IR-Xe 65' x 3'3-3/8" .... ...... ASTM D 1970 A fine granular/sand top surfaCe self-adhgjgg,:4PP •, Manufacturing Or 65' x 3' polymer modified, frberglass'r'bMdfoTced, Bituminous Location #I & #2 60 mils thick sheet material for use as an tITerl`a ment in slo ed roei:•..: ••••Y ••••p • assemblies. Designed as an iep•c�•rlrin shN4. • • • • • • • Polystick Dual Pro 61' x 3'33/8" TAS 103 and A rubberized asphalt self-adl *r:Ai,:glass4'ibar7I olyest* * *' * • Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membr�� �. Designed as a • • Location #2 metal roofing and roof tile ugderta.):nent. . • • ��; • Polystick Tile Pro 61' x 3'33/$" •�...•..• TAS 103 and A rubberized asphalt self-adl�rirtg,�lass-Tiber/�polyeste r • • • Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. DesW43s a metal Location 42 roofing and roof tile underlayment. Polystick TU Max 65'8" x 3'3-3/8" TAS 103 and A rubberized asphalt self -adhering, polyester reinforced Manufacturing 60 mils thick ASTM D 1970 waterproofing membrane. Designed as a a roof tile Location 41 & #2 underlayment. Polystick TU P 32' 10" x 3'33/8" TAS 103 and A rubberized asphalt waterproofing membrane, glass - Manufacturing 130 mils thick ASTM D 1970 fiber/polyester reinforced, with a granular surface Location #2 designed for use as a the roof underlayment. Polystick TU Plus 65' x 3'33/$" TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester (Surface Printing) 80 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a metal Manufacturing roofing and roof tile underlayment. Location #1 & #2 Polystick MTS 65'8" x 3'33/8" TAS 103 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefrnic film Location #2 on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Polystick MTS Plus 65'8" x 3'33/8" TAS 103 A homogeneous, rubberized asphalt waterproofing Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefrnic film Location #2 on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Elastotlex S6 G 32'10" x 3'3 %" TAS 103 and Polyester reinforced, SBS modified bitumen membrane Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For Location #2 use in roof tile underlayment systems. MIAMFDADE COUNTY NOA No.: 17-0614.22 UQUHM411 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL Test Azencv Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc LABELING: EVIDENCE SUBMITTED Test Identifier Test Name/Report P10870.09.08-R1 P10870.04.09 P33360.06.10 P33370.03.11 P33370.04.11 P36900.09.11 P37300.10.11 P40390.08.12-2 P37590.07.13-1 P45270.05.14 P46520.10.14 P44360.10.14 P43290.10.14 PLYG-SC 10130.06.16-3 PLYG-10130.06.16-1 PUSA-035-02-01 PUSA-055-02-02 PUSA-089-02-01 TAS 103 TAS 103/ASTM D4798.& G155 ASTM D 1970 ; • • TAS 103 ASTM D 1623 •: • TAS 103/ASTM D4798 &•Cj1�5 TAS 110/ASTM D4798 & "l.9.70 ASTM D 1623 ...... ASTM D6164 • • • • TAS 103, TAS 110 & ASTM f:=3 ASTM D 1623 ' TAS 103 & TAS 114 • • • ASTM D 1970 & TAS 110 TAS 103 & TAS 110 ASTM D1970 & TAS 110 TAS 103 TAS 103 TAS 103/ASTM D4798 & G 15 5 JX20117A TAS 103/ASTM D4798 & G 15 5 RX14E8A TAS 103/ASTM D4798 & G 15 5 DX23D8B TAS 103/ASTM D4798 & G155 DX231)8A TAS 103/ASTM D4798 & G155 Date 12/04/08 • • "13/09 •4'h'O1/10 •••••• • 04/26/11 •••••• • •oj01/11 . 408W07112 .....' 6•47+'52/13 •••••• 05/12/14 •. 10/07/1400 �••••� •.•VUt7/14 • • 06/27/ 16 06/27/ 16 09/29/06 12/10/07 07/06/09 04/01 /08 11 /09/09 02/18/10 02/18/10 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMFDADE COUNTY F_11=011311 BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. MIAMFDADE COUNTY NOA No.: 17-0614.22 • Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) ' Membrane: *000 Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick %U Max, Polystick• • • •; • TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus sell adh&@4.:. '. Surfacing: See General Limitations Below. ...... .... .... . . .... .... ..... Deck Type 1: Wood, non -insulated • •; • •; , • • • • • • • Deck Description: .. .. .. . ...... Min. 19/32" plywood or wood plank ...... • System Type E(2): , Anchor sheet mechanically fastened to deck, membrane adhered • ; ; • • • • • • Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. '..' ; ; • • • •; Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"Ife'atl lap. (for base sheet only) Membrane: Elastoflex S6 G, hot asphalt applied Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Membrane: Polystick TU Plus, self -adhered. Surfacing: See General Limitations Below. MIAMFDADE CO NOA No.: 17-0614.22 • • • • UNTY Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 4 of 8 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable btikiing code. 4. When applying the membrane in the valley, start at the low point and work to the high pp1iat, rolling file membrane from the center outward in both directions. • * • :...:. .. ...... . .... 5. For ridge applications, center the membrane and roll from the center outward in bothdilections. . 6. Roll or broom the entire membrane surface so as to have full contact with the surface' gMpg speptd1*Atentiod • to lap areas. •••• •••• •• ••••• • . " rent PrAlt Contro....7. Flash vent pipes, stacks chimneys and penetrations in compliance with Roof Asse> • 9• Notice of Acceptance. • 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing t4W.! pNl be • • • • • • pressed in place and formed around the protrusion to ensure a tight fit. A second la;er Qf Polystick shall be :....: applied over the underlayment. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing. Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems. Polystick TU Max may be used in non-structural metal roofing and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Ex osure Limitations (Days) MTS IR-Xe Elastoflex S6 G TU Plus TU P Tile Pro Dual Pro TU Max MTS Plus Winter Haven, FL 180 90 180 180 180 180 180 180 180 Hazelton, PA N/A 90 N/A 180 N/A N/A N/A 180 N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and MIAMFDADE COUNTY NOA No.: 17-0614.22 �rjumenall Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 5 of 8 , Rule 61G20-3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Pro is limited to mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. • . . .... ...... 9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, We n?aximiUrQO f slope •, .00000 • ...... shall be as follows: (See Table Below) Tile Polystick Elastoflex Polystick TU Plus, Polystick Poly%di!lt •, SySfflM JE3) • Profile MTS S6 G TU P, Tile Pro, TU Max MTS Pru's' MTS 'Abs with* Dual Pro 0 0:6 0: •')T>t -Pkis Flat Tile Prohibited 4:12 6:12 6:12 512%e: 6t12 Without battens • Profiled Prohibited 4:12 6:12 6:12 442 6:12 :. Tile without battens • The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall be utilized during loading and installation of tiles. 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for all underlayments except Polystick MTS which shall be loaded onto battens. d a 0 co N t0 POL`rSflCKTU Plus NOA No.: 17-0614.22 CMIAMMADECOUNTY • • • . , Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 6 of 8 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may barrradp to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Sec:io4fgr appro"t provided* • •; • that appropriate documentation is provided to detail compatibility of the products, win$ uplift resir;tat4, and fire ...... . ...... testing results. ...... .... .... . . POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICIrMEMBRANES ...... 000000 ..... PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPQ.F 0 APPLIC �TIONS. *00'' • LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOVMLNDATICgNS.. ....;. ...... 1. Polyglass does accept the direct application of Polystick underlayment membranes to Weo*; decks o In.tallers axe • •: cautioned to refer to applicable local building codes prior to direct deck installation to ensure this if aeCeptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum I V metal disk as required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and 410. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for pitch/slopes of 7/12" or greater. It is suggested that on pitch/slopes in excess of 6•'/4"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. MIAMFDADE COUNTY NOA No.: 17-0614.22 U19VOYA411 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 7 of 8 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. "" . . .... ...... 13. Questions in regards to the application of Polyglass products should be directed to our•Techlical Services .' Department at 1 (800) 894-4563. • • • • • • ...... 14. Polyglass recommends that applicators follow good roofing practices and applicable ; " 0 0 0lures as Qu0,ljned by; • • • •; the National Roofing Contractors Association (NRCA). • .... .... ..... ...... •. • ..... PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPffi1I * C APPLICATIONS. 11'�k LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND REC0M;4ATIWS. • ....;. . END OF THIS ACCEPTANCE " ' 0 •"• ' MIAMFDADE COUNTY NOA No.: 17-0614.22 • Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 8 of 8 TM MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.niiamidade.izov/economv ICP Adhesives and Sealants, Inc. 12505 NW 441' Street •••• Coral Springs, FL. 33065 • . . .... ...... SCOPE: ...... . ..... This NOA is being issued under the applicable rules and regulations governing the use of construction materials. TI;a • • •: documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control K; j�ion to q. ...0 . used in Miami Dade County and other areas where allowed by the Authority Having JurisdicJip.6P.(.&HJ). to This NOA shall not be valid after the expiration date stated below. The Miami -Dade County F}roduct CoMrol Section***:* (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the AiNto have A§ produjt • •; • or material tested for quality assurance purposes. If this product or material fails to perform yi the•acceptQd Md'rlher, tlw manufacturer will incur the expense of such testing and the AHJ may immediately revoke, W. f3t or suspend the use • • •: of such product or material within their jurisdiction. RER reserves the right to revoke this acceplatioes•if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. Kell Ile �-, NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. a's described .. ... ...... in this Notice of Acceptance. For the locations where the design pressure requirements, as determined bx appricable • • building code, do not exceed the design pressure values obtained by calculations in complia ce *Lth Roofing:• ••e•;. Application Standard RAS 127. For use with approved flat, low, and high profile roof tile VsjUs using ICP Adhesives Polyset® AH-160. • • •' •' .... .... . . .... •..• ..... PRODUCTS MANUFACTURED BY APPLICANT: • • • • • • • • • • • • • • •0 Product ••��•• Dimensions Test ProductDeccrintion .• Specifications : ' : ...... ICP Adhesives N/A TAS 101 Two component p4VPAtane �oargeadhesigt•••; Polyset®AH-160 • ICP Adhesives Foam N/A Dispensing Equipment Dispenser RTF1000 ICP Adhesives ProPack® N/A Dispensing Equipment 30 & 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 1.6 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ftz Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -400 F., 2 weeks +6.0% Volume Change @1580F., 100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. MIAMI•DADE COUNTYIM NOA No.: 17-0322.03 �FJNUNI Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Azency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-1PA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02JQ1/�4 Polymers Division , . . . .... ...... Ramtech Laboratories, Inc. 9637-92 ASTM E 108 VIQ/g'3 • � • ...... • • • Southwest Research Institute 01-6743-011 ASTM E 108 :::::e 1 j1Md/9¢ ' 01-6739-062b[l] ASTM E 84 "" 017MM5 ��:��• Trinity Engineering ineerin g 7050.02.96-1 TAS 114 • • • • 03%W96 • "' ;' P3 6700.04.12 ASTM D 1623 � � � � � � 01/ 18/12 ; . P39740.02.12 TAS 101 TAS 123 02f21'/12 .... Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. MIAMI•DADECOUNTY NOA No.: 17-0322.03 "' • Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance. Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and license&by i,�P Adhesivejjs and ... s e • Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicatoji Yq 1he auj"-having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is r;gti"j befog appUcatioil of any adhesive. The mix ratio between the "A" component and the "B" component shalr56 maintainedbetween •:' * - 1.0-1.15 (A): 1.0 (B). •••"' " ' ""' .. .. .. . ...... 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispense.bRii;F-1400 or ICP •s Adhesives ProPack® 30 & 100 dispensing equipment only. :*so*: 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. .. ; • • • •; 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP AdheAves Polyset® AH-160 has been dispensed. 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. MIAMI•DADE COUNTY NOA No.: 17-0322.03 UgVerpol Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches •30••. Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at* �• 12 grams per.paddy head of tile 9-11 sq, inches at. overlap . •... .:.. • Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal • ...?7 graihj jVrbead .. edge) 20-25 sq. inches each . bead .... .. . .. ' Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches • 3$ grants under pan .. LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. �PPR4�k'E� BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MIAMI-DADECOUNTY NOA No.: 17-0322.03 F!Ijj:(Syj;o_j Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 9w161rircuphplastke.anarrt vaddV[Banaashr") Ott" raquirik! y� UiwdetlYymafiC °'�"�''�, Faw roue. +�2.11n f asc4r r� Ewa fissure Hall through pl'astk eemeM. 4when required) 1dhux*�., 21n wldar. sane": vpsi.oal y T ,101M TM Cava cloaura Sava Course"' ~ ! 'ti-- Fascia J' U4 {hed40b P14041C �aihanraquiSmly � ,�.' p�dYl�+in4ethTllel nd4rlxyn+�air p "'�^. ii »wCaursa XFASCU 10in. in. ! E•v+rclasure ..►'� �^ Y,l'�' tlrlpodga MIAMI•DADE COUNTY ,..., �. Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cmZ) square ijWb adhesive contact with the underside of the tile....' ...... • Medium Profile / Double P'ari le • • 1. Starting at the eave cou¢e, ap;ly a minimum 2" ....:. (50.8 mm) x 10" (254 nLm) x.l" (25.: mMTfoam • • paddy onto the underlayrx%At positionedes�howrn • under the pan portion of the tile closesttothe overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cmZ) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2. At the second course, appl};a rgiNmum 2"(MU 8mm7 x 7" (177.8 mm) x 1" (25.4 ri'ifn) foam paddy onto the • • • underlayment positioned as s1�o+rvn under the strengthening rib closest to the: pyerlock oj�Lg tile being set. • .... .... ..... ...... .. . ..... 3. Continue in same manner. Inc "alpproxlmcbly 10" • • • • • • (64.5 cmZ) - 12(77.4 cmZ) squata;nch adhesive •. contact with the underside df the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cmZ) — 23 (148.4 cmZ) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cmZ) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) MIAMI•DADE COUNTYRI NOA No.: 17-0322.03 • , Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Wail dwough tvAenreq�2 "' P�ddyl6rrn•r+lrTilw? it•rFiyearhe '� a a In. I;aleeas 00donal lhh•phaW 1 o ir. an. Lew doswc Drip edge MIAMI•DADE COUNTY F.11JUSY1411 High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm') — 23 (148.4 cmZ) square inch adhesive contact with the underside of the tile. • • • • . . •••• •••••• 2. At the second course, apply 2Pmitlimurr:2' 4N.8mm) '. x 7" (177.8 mm) x 1" (25.4 M11 foam 13add.y onto the • • • • underlayment positioned as *sfiown under th� •pan ; • • • •; portion of the tile closest tvglle•Qverlocltpf*jbe tile being set. • ...... .. . .... ..... • .. . • ...... 3. Continue in same manner. iagme approximately 17" •, (109.7 cm') - 19 (122.6 cm:) squ;e inctipAVgive •"• contact with the underside Qf t4e �le. • :....: NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 Mil through plastiecement Paddy tbetween tiles) iwhen required) sattens optional 1 Paddy hinder tiles Sirtglepad'dp oaiopoft7e f� undwp ertt Single paddy il on un deriaymeat 2 x a in. r 10 o e2in. ascia Eave closure mmmmmi Flat(Low Profile Tile Hail through plastic cement SAngie paddy under the iwhen required) Paddy lbetween tiles) Battens anai Paddy (under tile) x Single pad ontapofthe x 4 in. x a undeIle paddy art y+ne,►t ,, 0� ti tin. Eave Closure Eave Course fascia Medium ProfileTile MIAMIQADE COUNTY Fil ... ton r On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x V (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the the for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure.... approximately 17-23 in2.(109.7-148.4 cvi2 of .... •. adhesive contact with thtaxiderside 4the•tile • Apply a 4" (101.6 mm) K" 91.6 mAj k'L" (25.� mm) foam paddy onto the dilderlaymentlust Belo j • .mow.•. •• •••• the second course line positioned foam Xdy .. .. . ...... under the strengthening ��!'pt flat tile, or. under the pan portion of the tile, clpse! t tp the underlock for....:. the second course tile to be installed. Insure • approximately 8-9 in' (5 T b•X:1 cm2t oft adhesive' • contact with the underside of the tile. • •.. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) #Nail through ptastic ae 5irtgle paddy under tile twhen required) Paddy ibetween tiles) Battens opttonat + Paddy{undertile) klep�aadddy onundertaymen w�4X 4 in. shtoe 2.x 411n.pay. ttop'otale Eave Course fasda WeVhole to In. 2 in. Eave closure Drip edge High ProtlleTlle MIAMI•DADE COUNTY ... 1r 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 1/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cmZ) - 11 (71cm') square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cmZ) - 9 (58.1 cmZ) square mM* • • • • • • adhesive contact with th; iL ejside q�t�ieetile at •" the head of the tile. Conl ;V% jig sameptWiMr. ....:. sees•• sees sees . • e••• +••• sees• sees** •• • sees• • •aces• s • • • • • •aces• NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL t) Place enough adhesivato achieve b5 to 70sq.1n. Steep pitch applications in contact with the pan tile. when required) 2) Turn covers upside down. Place adhesive in to t In: from outside edge of cover tile. Then install the tile. Ensure<20 to 25 sq. In. contact area. o Underlayment o 0 - o Eave closure (motar shown) Fascia Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure eeve and of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile MIAMI•DADE COUNTY F-111111MY1411 Two Piece Barrel (Cap and Pan) Tile j . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. • • •. 2. Continue in same mannennringing tg9M •. courses up toward the ritft!h)sure• """ approximately 65 (41904 Lh*J — 70 (45 ?.6 cm2) square inch adhesive caMaclwith tiva un�erside 0 00000 Of the pan tile. •••••• *so***••••• 3. Turn covers upside do,4v o }posing the underside • of the tile. Apply a mir:mum Z" (25*4 mire x 10'+0 •• • • (254 mm) bead of adhecive.di;ectlyvn the inner:,,,,: edge of each side of the eeveitile. Itayt'. ' approximately 3/4" (19 mm) to 1" (23.14'mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm') - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11