RF-18-200414
�` SHORES Litt
yYt H'�Ov
F�pRAID
Miami Shores Village
10050 N.E. 2nd Avenue NW
Miami Shores, FL 33138-0000
Phone: (305)795-2204
Project Address
400 NW 112 Terrace
Miami Shores, FL 33168-3328
Owner
(Permit
Parcel Number
1121360010200
Block: Lot:
GREGORY PECCHIO 400 NW 112 Terrace
MIAMI SHORES FL 33168-3328
Contractor(s) Phone Cell Phone
ESTRADA ROOFING (786)385-3137
of Work: Re Roof
onal Info: RE -ROOF SLOPE ROOF STANDING SEAM ME
ification: Residential
ring: 4
Fees Due
Amount
Bond Type - Contractors Bond
$500.00
CCF
$19.80
DBPR Fee
$4.13
DCA Fee
$2.75
Education Surcharge
$6.60
Permit Fee - New Roof
$275.00
Scanning Fee
$12.00
Technology Fee
$26.40
Total:
$846.68
Issue Date: 81812018
Permit NO. RF-7-18-2004
Permit Type: Roof
Work Classification: Metal
Permit Status: APPROVED
Expiration: 02/04/2019
Applicant
GREGORY PECCHIO
Phone Cell
Valuation: $ 33,000.00
Total Sq Feet: 1694
Pay Date Pay Type Amt Paid Annt Due
Invoice # RF-7-18-68350
08/08/2018 Check #: 7158 $ 796.68 $ 60.00
07/26/2018 Check #: 7133 $ 50.00 $ 0.00
Bond #: 3854
,avauame I
Inspection Type:
Tin Cap
Final Roof
Cap Sheet
Roof in Progress
Renailing Affidavit
Review Roof
Review Planning
Review Planning
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
constructio nd Zoning. Futherm re, I aut onze the above-n ed contractor to do the work stated.
`�=N ( �'1�Q�QZ August 08, 2018
utho ized SigoturoWner / Applicant / Contractor /
Building Department Copy
August 08, 2018
16
v
BUILDING
PERMIT APPLICATION
❑BUILDING ❑ ELECTRIC
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138 [BY — — —
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
FBC 20 (�-
Master Permit No. 2Ee - 2 0--:T
Q ROOFING ❑ RE ISION
Sub Permit No.
❑ EXTENSION ❑RENEWAL
❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 400 NW 112 TER
City: Miami Shores County: Miami Dade zip: 33168
Folio/Parcel#: 11-2136-001-0200 Is the Building Historically Designated: Yes NO X
Occupancy Type: Load: Construction Type: Flood Zone: BFE: 1 FFE:
OWNER: Name (Fee Simple Titleholder) ire !2 Pac�—kw Phone �J7e;q — 73�d
Address: 400 NW 112 TER Of I
City: MIAMI SHORES State: FL zip: 33168
Tenant/Lessee Name: Phnna#t-
E
CONTRACTOR: Company Name: ESTRADA ROOFING
Address: 1738 SW 57 AVE
hone#: (786)385-3137
City: MIAMI State: FL Zip: 33155
Qualifier Name: DANIEL GONZALEZ-LAUZAN Phone#: 305-668-8800
State Certification or Registration #: CCC1328913 Certificate of Competency #: _
DESIGNER: Architect/Engineer: Phone#:
Address: City: Stat
Value of Work for this Permit: $ 33,000 Square/Linear Footage of Work: _
Type of Work: ❑ Addition I Alterat'on _Ej New _ Q Rppair/Replace
Description of Work: ��--
_ Zip:
qly SST
ition
Specify color of color thru tile: `CC�C�1/t--Z
Submittal Fee $ ' Permit Fee $ Cp CCF $ y CO/CC $
Scanning Fee $ I Z Radon Fee $ a ` 5 DBPR $ 13 Notary $
Technology Fee $ ' G Training/Education Fee $ 60 Double Fee $
Structural Reviews $ Bond $ ;cj(,) ' 0;z)
TOTAL FEE NOW DUE $
(Revised02/24/2014)
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. 1 understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature n Signature
WNER or AGENT CONTRAC OR
The foregoing instrument was acknowledged before me this
23 day o _ 20 ] by
Cn V-(rr I� who ' �n to
me or who has produced as
identification and who did take an oath.
NOTARY PUBLIC:
Sign
,>�" Notaryy Public State of Florida
Seall Anailyn Estrada
4g My Commission GG 173158
a�y8 Expires01/10/2022
APPROVED BY
The foregoing instrument was acknowledged before me this
E day o ` , 20 �by
��i�6'71nwD,-�N110 to
me or who has produced
identification and who did take an oath.
NOTARY PUBLIC:
i7l,-117.10
Seal:
t
or n
Plans Examiner
Structural Review
as
Notary Public State of Florida
Anailyn Estrada
My Commission GG 173158
Expires 01/10/2022
VVV
Zoning
Clerk
(Revised02/24/2014)
7/23/2018 Property Search Application - Miami -Dade County
OFFICE OF THE PROPERTY APPRAISER
Summary Report
Property Information
Folio:
11-2136-001-0200
Property Address:
400 NW 112 TER
Miami Shores, FL 33168-3328
Owner
GREGORY J PECCHIO
Mailing Address
400 NW 112 TERR
MIAMI SHORES, FL 33168-3328
PA Primary Zone
0700 SGL FAMILY - 1551-1700 SQ
Primary Land Use
0101 RESIDENTIAL -SINGLE
FAMILY: 1 UNIT
Beds / Baths / Half
3/2/0
Floors
1
Living Units
1
Actual Area
Sq.Ft
Living Area
Sq.Ft
Adjusted Area
1,661 Sq.Ft
Lot Size
7,500 Sq.Ft
Year Built
1955
Assessment Information
Year
2018
2017
2016
Land Value
$161,028
$161,028
$134,829
Building Value
$115,606
$115,606
$115,606
XF Value
$2,166
$2,188
$2,209
Market Value
$278,800
$278,822
$252,644
Assessed Value
$89,163
$87,3301
$85,534
Benefits Information
Benefit
Type
2018
2017
2016
Save Our Homes
Cap
Assessment
Reduction
$189,637
$191,492
$167,110
Homestead
Exemption
$25,000
$25,000
$25,000
Second Homestead
Exemption
$25,000
$25,000
$25,000
Note: Not all benefits are applicable to all Taxable Values (i.e. County, School
Board, City, Regional).
Short Legal Description
NEW MIAMI SHORES ESTS PB 51-80
LOT 4 BLK 2
LOT SIZE 75.000 X 100
OR 11851-0819 0683 4
Generated On : 7/2312018
Taxable Value Information
2018
2017
2016
County
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
1 $39,163
$37,330
$35,534
School Board
Exemption Value
$25,000
$25,000
$25,000
Taxable Value
1 $64,163
$62,330
$60,534
City
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
1 $39,163
$37,330
$35,534
Regional
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$39,163
$37,330
$35,534
Sales Information
Previous Sale I Price OR Book -Page Qualification Description
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
Version:
OWNER'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PURSUANT TO SECTION 553.844 F.S.
04/20/2018
To: City of Miami Shores
10050 N.E. 2nd AVE
Miami Shores FL 3313b
Re: Owner's Name
Property Address
Roofing Permit Number
Ci .01
400 NW 112 TER
Dear Building Official:
I ('"k, certify that I am not required to retrofit the roof to wall
connections of my building because:
❑✓ The just valuation for the structure for purposes of ad valorem taxation in less than $300,000.00.
❑ The building was constructed in compliance with the provisions of the Florida Building Code
(FBC) or with the provisions of the 1994 edition of the South Florida Building Code (1994
SFBQ.
Signa e of Property Owner
o 'a
Print Na(ne
STATE OF FLORIDA COUNTY OF MIAMI-DADE
Sworn to and subscribed before me this 2
day of 20 IS
(SEAL)
�'40 � Notary Public State of Florida
Anailyn Estrada
, My Commission GG 173156
Personally known Of Expires 01/10/2022
or Produced Identification
When the just valuation of the structure for purposes of ad valorem taxation is equal to or more than
$300,000.00, and the building was not constructed in compliance with the FBC nor with 1994 SFBC,
and affidavit of Roof to Wall Connection Hurricane Mitigation Retrofit must be provided.
C:9)o—nls end Settmp\c ,I\My Ibc�anentst5tntisticsGrapl�s_2Utenf g Affidavit ConTh-v 9 26 07FRI.b],d-
. 1 1
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section A (General Information)
Master Permit No. '�' �U ' 2<3Jq Process No.
Contractor's Name ESTRADA ROOFING
,lob Address 400 NW 112 TER
ROOF CATEGORY U
❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles
❑ Asphaltic Shingles ■ Metal Panel/Shingles ❑ Wood Shingles/Shakes
❑ New roof ❑ Repair
Low Slope Roof Area (SF) 0
❑ Prescriptive BUR-RAS 150
ROOF TYPE
❑ Maintenance ■ Reroofing
ROOF SYSTEM INFORMATION
Steep Sloped Roof AREA (SSF) 1,694
Section B (Roof Plan)
2 6 2018
❑ Recovering
Total (SF) 1,694
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen-
sions of sections and levels, clearly identify dimensions of elevated zones and location of
pressure
parapets.
tree
1. , ..••
..
• •
e
..... .
x..
•sees•
r
• e
14
• • • •
• • •
• • • • •
25
yy • • • • •
2 14
•e
• •
seeee
• f
•1e:
ee•ww•
•
•
• •
, •
•
• f
•
•
•• •
on •
sees••
t• •
FLORIDA BUILDING CODE — BUILDING, 6th EDITION (2017)
33
Miami Shores Village
APPROVED BY DA
A4
1, ).,I C f 10 GO.J,'LIANCE WITH ALL FEDERAL
469
�:, vif AND C:)L,' q1Y RULES AND nFGULATIONS
> > 1
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section D (Steep Sloped Roof System)
Roof System Manufacturer:
MAJOR'S METAL ROOFING & CUSTOM SHEET METAL
Notice of Acceptance Number: 16-0224.13
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): el
P1: -39.1 P1: -68.1 P1: -100.7
MAXIMUM DESIGN PRESSURE PRODUCT APPROVAL SPECIFIC SYSTEM: -131 PSF '
Roof Slope: 1
3 : 12
Deck Type: 5/8" PLYWOOD /
\ Type Underlayment: 30# ASTM D226 FELT
Insulation: N/A
Fire Barrier: GAF -ELK VERSASHIELD • T 0A ATTACHED!...:
Ridge Ventilation? Fastener Type & Spacing: 34in. OC Field-,*89 OC Arirtltter &
N/A \ Corners - 2 #'1T:S:Cews pQr 2in.clip 'r`
....
Adhesive Type: SELI.XATJEREQ :...
Type Cap Sheet: POLYSTICK TLi'PGC.ItS
Mean Roof Height: 12 Roof Covering: 24GA. S. SEAM 16IN. WIDE
Type & Size Drip 3"X3n 26GA GALV.
Edge: --
Perimeter Width: 5
FLORIDA BUILDING CODE — BUILDING, 6th EDITION (2017) 471
7/1312016 , r
TGFU.R21453- Roofing Systems
Page Bottom
See General Information for Roofing Systems
TGFU.R21453
Roofing Systems
Roofing Systems
MAJORS METAL ROOFING 8t CUSTOM SHEET METAL INC
406 NW 54 ST
MIAMI, FL 33127 USA
R21453
Any UL Classified peel and stick underlayment may be used in conjunction with either "VersaShield" or a Type 30 base sheet, in any of the
following systems.
OTHER SYSTEMS
Class A
••••
Deck: C-15/32 Incline: Unlimited • • • 0000
• • • • • • •
Barrier Board: — G-P Gypsum 1/4 in. min DensDeck ® board or 1/2 in. min. UL classified gypsum board with all join&%t$ggered j • •;.
min of 6 in. from the plywood joints. "';"
Ply Sheet (Optional): — Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15 or 30 felt ortX"Mified prepated roofing
accessory or GCP Applied Technologies Inc. "Ice and Water Shield". • • • • • • • • •
Surfacing: — "Copper 1.5" Mechanically Seamed panels, "Steel 1.5 Mechanically Seamed" panels, "ATiyyipyth 1.5" &tec•IWvcally • • • • •
Seamed panels" or "5 Crimn" panels. merhanically fastenedi_ • '
2. Deck: C-15/32 or spaced sheathing Incline: Unlimited
•••••• •••• •••••
•
•••••• • •
Underlayment: — One layer Elk Corp. "VersaShield Underlayment, mechanically fastened. : • : • • • • • • : •
Ply Sheet: — One layer Type 30 base sheet or "VersaShield", mechanically fastened.
Panels: — "Cooper 1.5" Mechanically Seamed panels, "Steel 1.5 Mechanically Seamed" panels, or "5 ErimV panels,• � gchpnically •' • • ;
fastened.
• • •
3. Deck: C-15/32 or spaced sheathing Incline: Unlimited
Underlayment: — One or more plies Elk Corp. "VersaShield Underlayment", mechanically fastened.
Panels — "Cooper 1.5" Mechanically Seamed panels, "Steel 1.5 Mechanically Seamed" panels, or "5 Crimp" panels, mechanically
fastened.
4. Deck: C-15/32
Incline: Unlimited
Underlayment: — Two layers Elk Corp. "VersaShield Underlayment", mechanically fastened.
Panels— "Aluminum 1.5" Mechanically Seamed Panels".
Class B
1. Deck: C-15/32
Incline: Unlimited
Underlayment: — One layer Elk Corp. "VersaShield Underlayment', mechanically fastened.
Panels: — "Cooper 1.5 " Mechanically Seamed panels, "Steel 1.5" Mechanically Seamed panels, "Aluminum 1.5" Mechanically Seamed
Panels", or "5Crimp panels mechanically fastened.
2. Deck: Spaced Sheathing
Incline: Unlimited
Underlayment: — One layer Elk Corp. "VersaShield Underlayment'.
Panels: — "Cooper 1.5" Mechanically Seamed panels, "Steel 1.5 Mechanically Seamed" panels or "5 Crimp" panels, mechanically
fastened.
1. Deck: C-15/32
Class C
Incline: Unlimited
Vapor Barrier (Optional): — Any UL Classified base/ply sheet.
Surfacing: — "Cooper 1.5" Mechanically Seamed panels, "Steel 1.5' Mechanically Seamed panels, "Aluminum 1.5" Mechanically
Seamed panels or "5 Crimp" panels, mechanically attached.
Last Updated on 2016-06-02
http://database.ul.com/cgi-binrCYV/templateR JSEXT/1 FRAM Elshawpage.htmI?name=TGFU.R21453&ccnshortfif e=Roofing+Systems&obj id=1076548337&dgi... 1/2
MIAMF e
f
"Delivering Excellence Every Day"
------ MIAMI-DADE COUNTY
REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS
It is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to
explain to the owner the content of this form. The owner's initials in the designated space indicates that the item
has been explained.
do
1. Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane
Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion
performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions.
Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed
as part of the agreement between the owner and the contractor.
2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be
r nailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones)Af the Florida
Building Code. (The roof deck is usually concealed prior to removing the existing roof �sy�stem)�.• • • • • ....:.
.. . 0000 . •
3. Common roofs: Common roofs are those which have no visible delineatimtbttween �ighbofih'g"
units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roo pgcontraCtor.and/ot""'
owner should notify the occupants of adjacent units of roofing work to be performed' ..•• • 0 • • 0 • • ; • • .
...... .... .....
4. Exposed ceilings: Exposed, open beam ceilings are where the underside * -of the roof �iecicing cafi'04'
vi ed from below. The owner may wish to maintain the architectural appearance; VArrre, rgoeing nail...,;.
penetrations of the underside of the decking may not be acceptable. The owner provides tie option of• •
maintaining this appearance. •• .".'. '
1 ;4 J 5. Ponding water: The current roof system and/or deck of the building may not drain well and may
cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural
distress and may require the review of a professional structural engineer. Ponding may shorten the life
expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original
roofing system is removed. Ponding conditions should be corrected.
6.Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not
overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if
overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance
with the requirements of. Chapter 15 and 16 herein and the Florida Building Code, Plumbing.
7. Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be
reduced.
Owner's/Agent's Signature: ate:
Contractor's Signature: Permit Number:
Property Address: 400 NW 112 TER
MIAM
.�I i)
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA
Major's Metal Roofing & Custom Sheet Metal, Inc.
406 NW 54"' Street
Miami, FL 33127
SCOPE:
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.eov/economy
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this uteeptance* • •;'
if it is determined by Miami -Dade County Product Control Section that this product or materhA fads to rile& tit '.
requirements of the applicable building code. • • • 6 •
This product is approved as described herein, and has been designed to comply with the Flor i0aA lilding:Cbdr' .....
including the High Velocity Hurricane Zone of the Florida Building Code. 000000 .... • • : • • •
DESCRIPTION: Steel 1.5" Mechanically Seamed Panel ; • • ; • ; 00
......
LABELING: Each unit shall bear a permanent label with the manufacturer's name o v� e, city, stge end ; • • • • ;
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted hlexera.'
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of
any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to
comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA # 14-0515.14 and consists of pages I through 7.
The submitted documentation was reviewed by Gaspar J Rodriguez.
NOA No.: 16-0224.13
Expiration Date: 06/17/19
Approval Date: 03/24/16
Page 1 of 7
,
ROOFING ASSEMBLY APPROVAL:
Category' Roofing
Sub -Category: Non -Structural Metal Roofing
Material: Steel
Deck Type: Wood
Maximum Desien Pressure: See Table A & Table B
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product
Dimensions
Specifications Description
Steel 1.5" Mechanically
Length: varies
TAS 125 Corrosion resistant galvanized or
Seamed Panel
Coverage width: 12", 16" & 20"
galvalume preformed, coated, prefinished,
Height: 1.5"
metal panels.
min. 24 gage (0.0239")
Min Yield Strength: 26 KSI
Panel Clip
Length = 2"
TAS 110 ASTM Grade 50 preformed, galvalume
Width = 3/4"
steel clips with two preformed holes.
Height = 1.5"
• • • •
min. 24 gage (0.0239")
a
, `•' • ``• • •
Stainless Steel Panel
Length = 2"
TAS 110 Grade C prefomwJ, stainless sisal clips... •: •
Clip
Width = 3/4"
with two prefonot6holes. •
Height = 1.5"
• • • • • •
min. 24 gage (0.0239")
•"' `• • • • • •
•••••• •••• •••••
•• •• •• • ••••••
TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS • •
......
. . . . ......
Product
Dimensions
Product ••••••
Mahufacturer :.. • •
.' .
Description .. •
Fasteners
#10 Corrosion resistant steel screws for Generic
fastening of clip.
MANUFACTURING LOCATION:
1. Miami, FL
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Reyort
Valspar Corporation
ASTM G 23
ASTM B 117
PRI Asphalt
MRI-00 1 -0 1 -0 1
TAS 100
Technologies, Inc.
Hurricane Test
0299-0801-03
TAS 125
Laboratory, Inc.
Hurricane Test
0299-0320.04
TAS 125
Laboratory, Inc.
Date
08/18/03
10/27/03
03/25/04
NOA No.: 16-0224.13
Expiration Date: 06/17/19
Approval Date: 03/24/16
Page 2 of 7
System B:
Deck Type:
Deck Description:
Slope Range:
Maximum Uplift
Pressure:
Steel 1.5" Mechanically Seamed Panel, (Coverage width 12" & 16")
Wood, Non -insulated
New Construction 19/32" or greater plywood or wood plank, or for re -roofing 15/32"
or greater plywood.
2": 12" or greater
See Table B below
Deck Attachment:
In accordance with applicable Building Code, but in no case it shall be less than 8d
annular ring shank nails spaced 6" o.c. in the field and 4" o.c. along the perimeter of the
sheet. in reroofing, where the deck is less than 19/32" thick (minimum 15/32") the above
attachment method must be in addition to existing attachment.
Underlayment:
Minimum underlayment shall be a ASTM D 226 Type II installed with a minimum 4"
side -laps and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -
caps and P/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows
12" o.c. in the field of the roll. Or, any Miami -Dade County Product Control Approved
underlayment having a current NOA.
Fire Barrier Board:
Any approved fire barrier having a current NOA. Refer to a current ire dire';ox.,o listing.... •
for fire ratings of this roofing system assembly as well as the localKon;of theeftie.bVier • •
within the assembly. See Limitation # 1. • • • • • • ' • """
Valleys:
Valley construction shall be in compliance with Roofing Applicaj p"Standard RAS 133 : • • • •:
and with Major's Metal Roofing & Custom Sheet Metal, Inc.'s cYror"l publl"shed• • • • • • •
• • • • • • • "
installation instructions. • • • • • •P
Metal Panels and
Ike
Install the "Steel 1.5" Mechanically Seamed Panel" and accessojLeks p•compl ian je with • • • .'
Accessories:
Major's Metal Roofing & Custom Sheet Metal, Inc.'s current pilbligh& installation • • • • •
instructions and details. Flashing, penetrations, valley construction and other cfetai s shalf „•••;
be constructed in compliance with the minimum requirements provided in R945hpg• `
Application Standards RAS 133. " 0
Panels shall be installed with galvanize/stainless steel clips (2" long x 3/4" wide x 1.5"
tall), attached to substrate with two corrosion resistant steel #10 wood screw of sufficient
length to penetrate through the sheathing a minimum of 3/16". Clip fastening shall start
3" from panel end and shall be at maximum spacing as described below in Table B. there
after. Standing seams shall be mechanically seamed to a full 90' seam, (single lock).
TABLE B
MAXIMUM DESIGN PRESSURES
Roof Areas
Field
Perimeter and Corner'
Maximum Design Pressures
—57.3 PSF
—131 PSF
Maximum Clip Spacing
34" OC
S" OC
1. Extrapolation shall not be allowed
NOA No.: 16-0224.13
MAMMAD, COUNTY Expiration Date: 06/17/19
Approval Date: 03/24/16
Page 4 of 7
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended corners and corners).
3. Panels shall be roll formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in
Roofing Application Standard RAS 133.
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement:
"Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen
below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code. . •. •
. . .... ......
..•... .. ......
•••• • •• •••••
•••••• •••• •••••
•• •• •• • ••••••
•
• • • • ••••••
NOA No.: 16-0224.13
Expiration Date: 06/17/19
Approval Date: 03/24/16
Page 5 of 7
DETAIL DRAWINGS
0.53" STIFFENING RIBS 0.42"
0.36"
0.50"
0.10"
1.47"
1.50"
12", 16" & 20"
0.50"
APPROVED
0.25'
0.75" --
PANEL DETAIL
FOR
vs
PANEL CLIP DETAIL
PANEL 1MTH
SINGLE LOCK
.... .. ..
......
• ..
•
....
..... .
......
STEEL 1.5" MECHANICALLY SEAMED PANEL AND DETAILS
NOA No.: 16-0224.13
Expiration Date: 06/17/19
Approval Date: 03/24/16
Page 6 of 7
DRAWINGS CONT.
#10 FASTENERS
#10 FASTENERS
STANDING SEAM PANEL
END OF THIS ACCEPTANCE
NOA No.: 16-0224.13
Expiration Date: 06/17/19
Approval Date: 03/24/16
Page 7 of 7
RIDGE/HIP FLASHING
"J" CHANNEL
CLIP WITH SCREWS
FIELD BEND END CUT PANEL
(FORM AND BOX END)
ROOF NAIL
INTO "J" CHANNEL
APPROVED 4" O.C.
UNDERLAYMENT
1/8" RIVET 24" O.C.
ROOF PANEL
i•
••••••
t
PLYW6�0..
....�.
HIP / RIDGE DETAIL
STEEL (24 Ga.) - STANDING SEAM PANEL
15 -auk
406 NW 54 STREET MIAMI, FL 33127 - TEL: (305) 757-9504
FAX: (305) 757-4031 - E-MAIL: marvin@majorsmetal.com
APPROVED
UNDERLAYMENT
PANEL
171"
5/8" CDX
. .
""
"""
PLYWOOD
..
;;;;;;
•"
;"";
Y RAKE
.000
..
FLASHING
1 1/4" RING SHANK
......
..•..•
....
•..• :
.....
*000:0
ROOF NAIL 411 O.C.
:":':
. .
. .
'0
......
STAGGERED
: .•.
00
:....:
RAKE DETAIL o
STEEL (24 Ga.) - STANDING SEAM PANEL
406 NW 54 STREET MIAMI, FL 33127 - TEL: (305) 757-9504
FAX: (305) 757-4031 - E-MAIL: marvin@majorsmetal.com
CLIP W/ SCREWS
(1ST CLIP 3" FROM END)
ROOF PANEL
(FIELD CUT AND
HEMMED)
APPROVED
UNDERLAYMENT
5/8" CDX PLYWOOD
. . .... ......
WRAP
PANEL ...... .. ......
.*Goo:
3" BULLNOSE "" ""•
DRIP EDGE .. .. .. . ......
. . . . ......
00
WOOD BLOCKING
EAVE DETAIL
;
JIM
STEEL (24 Ga.) - STANDING SEAM PANEL
406 NW 54 STREET MIAMI, FL 33127 - TEL: (305) 757-9504
FAX: (305) 757-4031 - E-MAIL: marvin@majorsmetal.com
VENT PIPE
ROOF JACK
(DEKTITE OR EQUAL)
SCREWS AT 1" O.C.
ROOF PANEL
••+•
• •
••••
••••••
• • •
•
•
5/8" CD)t P11WOOD BECK'
••••••
••••
•••••
•• ••
•• •
••••••
•
• •
• •
••••••
ROOF PENETRATION
STEEL (24 Ga.) - STANDING SEAM PANEL
406 NW 54 STREET MIAMI, FL 33127 - TEL: (305) 757-9504
FAX: (305) 757-4031 - E-MAIL: marvin@majorsmetal.com
7
/ METAL SEALANT
L -- #10X1.5" WOODGRIP SCREW
• • •••• ••••••
•••••• •• ••••%
•
CANWAHED ATA $i0*C1.5" • • • • •
TRUEMQ'•94MOVABLVVREWS • • • • •
• • • • • • • • • • • • •
•
••••• • •
••••••
• s ••••••
#10X1.5" WOODGRIP SCREW
EMBEDD IN CAULK
TOP & BOTTOM
JOB NAME: ROOF JACK DETAIL
A �II
COMMENTS/DESCRIPTION: STEEL (24 Ga.) - STANDING SEAM PANEL
406 NW 54 STREET MIAMI, FL 33127 - TEL: (305) 757-9504
FAX: (305) 757-4031 - E-MAIL: marvin@majorsmetal.com
METAL SEALANT
L - - - - #10X1.5" WOODGRIP SCREW
• • •••• ••••••
•
••SS••
Soso Y• Y • •
• • • • s
•••••• •••• •••••
• o • • •
•
o••••• • •
000000
••••••
• • •
•• •
#10X1.5" WOODGRIP SCREW
EMBEDDIN CAULK /
TOP & BOTTOM
JOB NAME: GOOSE NECK DETAIL
COMMENTS/DESCRIPTION: STEEL (24
Ga.) - STANDING SEAM PANELAwrlp-
406 NW 54 STREET MIAMI, FL 33127 - TEL: (305) 757-9504
FAX: (305) 757-4031 - E-MAIL: marvin@majorsmetal.com
MIAMFQADE
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.¢ov/economy
Polyglass USA Inc.
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by -the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code. • • • • • • •
DESCRIPTION: Polyglass Polystick Underlayments ...... ....:.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo:e*it9'�tate a4d follpwing• •
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. 0 •" ..."
...... . .... .
RENEWAL of this NOA shall be considered after a renewal application has been filed and t1Z.has been go change .'
in the applicable building code negatively affecting the performance of this product. • : ....:.
.
TERMINATION of this NOA will occur after the expiration date or if there has been a revitton ar change jn the .
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.15-0410.04 and consists of pages I through 8.
The submitted documentation was reviewed by Freddy SeminoJ
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page l of 8
ROOFING COMPONENT APPROVAL
Catemory: Roofing
Sub-Cateeorv: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Polystick IR-Xe 65' x 3'33/8" ASTM D 1970 A fine granular/sand top surface self -adhering, APP
Manufacturing Or 65' x 3' polymer modified, fiberglass reinforced, bituminous
Location #1 & #2 60 mils thick sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice & rain shield.
Polystick Dual Pro
61' x 333/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a
Location #2
metal roofing and roof tile underlayment.
Polystick Tile Pro
61' x T33/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Location #2
roofing and roof tile underlayment.
Polystick TU Max
65'8" x 3'3-3/8"
TAS 103 and A rubberized asphalt self -adhering, polyester reinforced
Manufacturing
60 mils thick
ASTM D 1970 waterproofing membrane. Designed as a q roof file
Location # 1 & #2
.... .
underlayment. ......
d.
.. . . ...
Polystick TU P
32' 10" x 3'33/s"
TAS 103 and A rubberized asphalt waterproofij�g•membrane -glass- • • • • •
Manufacturing
130 mils thick
ASTM D 1970 fiber/polyester reinforced, wiflf Ir nular surface ;„• •
Location #2
f;
designed for use as a tile roounderlif • ayme0 .
.... . .. .....
Polystick TU Plus
65' x 3'33/8"
TAS 103 and A rubberized asphalt self-adht!fW, glass-�MC/pplyestef" • •
(Surface Printing)
80 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed a's a metAP..'
Manufacturing
roofing and roof underla) neont.: •
. . . ......
Location # 1 & #2
•
006
.. . .. .
Polystick MTS
65'8" x 3'33/s"
. •
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Polystick MTS Plus
6518" x 3133/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Elastoflex S6 G
32'10" x 3'3 %"
TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing
ASTM D 6164 with a sanded back face and a granule top surface. For
Location #2
use in roof tile underlayment systems.
NOA No.: 17-0614.22
MIAMFDAD; COUNTY Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
Z. Winter Haven, FL
Test Agency
Trinity I ERD
PRI Asphalt Technologies
Momentum Technologies, Inc.
EVIDENCE SUBMITTED
Test Identifier
Test Name/Report
Date
P10870.09.08-R1
TAS 103
12/04/08
P10870.04.09
TAS 103/ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
07/01/10
P33370.03.11
TAS 103
03/02/11
P33370.04.11
ASTM D 1623
04/26/11
P36900.09.11
TAS 103/ASTM D4798 & G 15 5
09/01/11
P37300.10.11
TAS 110/ASTM D4798 & D1970
10/19/11
P40390.08.12-2
ASTM D 1623
08/07/12
P37590.07.13-1
ASTM D6164
07/02/13
P45270.05.14
TAS 103, TAS 110 & ASTM D1623
05/12/14
P46520.10.14
ASTM D1623
10/03/14
P44360.10.14
TAS 103 & TAS 110
10/07/14
P43290.10.14
ASTM D 1970 & TAS 110
10/17/14
PLYG-SC10130.06.16-3
TAS 103 & TAS 110
06/27/16
PLYG-10130.06.16-1
ASTM D1970 & TAS 110
06/27/16
PUSA-035-02-01
TAS 103
. "09/29/06
PUSA-055-02-02
TAS 103 .0.
• * t2/l0/07 • * • • :'
PUSA-089-02-01
TAS 103/ASTM 1)4798 fir,,�J,��
• • •8Z;06/09 0; •
JX20117A
TAS 103/ASTM D4798 &C•1-55
.. 04/01/08:"":
RX 14E8A
TAS 103/ASTM D4798 & Cq-55
• } }%9/09• • • • •
DX23D8B
TAS 103/ASTM D4798 WCRIZ
.•'Q2/j8/10"" •�
DX23D8A
TAS 103/ASTM D4798 V(5n*55
......
. .
*•02n8/l00*0*:'
.
. . ..... .
LABELING: • • • • • •
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name of logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick
TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered.
Surfacing: See General Limitations Below.
Deck Type 1:
Wood, non -insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E(2):
Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet:
One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening:
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane:
Elastoflex S6 G, hot asphalt applied
Surfacing:
* 0 0 0
See General Limitations Below. •.. �. • �, �,
Deck Type 1:
...... .. ......
Wood, non -insulated ......
Deck Description:
Min. 19/32" plywood or wood plank '....' '..' .....
System Type E(3):
Base sheet mechanically fastened to deck, subsequent cap mletAbUne self **tiered. • • • • •
Anchor/Base Sheet:
.. .. .. . ......
One or more plies of ASTM D 226 Type II or ASTM D 2626. ...... .'
Fastening:
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4:hwd bap. (fd?
base sheet only) • • • • • .
Ply Sheet:
Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimitmK"
vertical laps.
Membrane:
Polystick TU Plus, self -adhered.
Surfacing:
See General Limitations Below.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of 8
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention
to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance. • • • •
. . ... ......
2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Pdlystict MT$.Rlus may be • •
used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, rocftWe-6ystems and quarr}c...:.
slate roof assemblies. • • • • • •
Polystick TU P may be used in all the previous assemblies listed except metal roofing •
Polystick IR-Xe maybe used in all the previous assemblies listed except metal roofing and roof the systems. •: • •.
.... .. . .....
Polystick TU Max maybe used in non-structural metal roofing and roof tile systems. • •, • • • • • • • •
Elastoflex S6 G may be used in roof tile systems only. ......
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Poly;SA lu P, Pdysqck TIRO •
Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface' iflie deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Ex osure Limitations (Days)
MTS
IR-Xe
Elastoflex
S6 G
TU
Plus
TU P
Tile Pro
Dual Pro
TU Max
MTS Plus
Winter Haven, FL
180
90
180
180
180
180
180
180
180
Hazelton, PA
N/A
90
N/A
180
N/A
N/A
N/A
180
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 5 of 8
Rule 61 G20-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope
shall be as follows: (See Table Below)
Tile
Polystick
Elastoflex
Polystick TU Plus,
Polystick
Polystick
System (E3)
Profile
MTS
S6 G
TU P, Tile Pro,
TU Max
MTS Plus
MTS Plus with
Dual Pro
TU Plus
Flat Tile
Prohibited
4:12
6:12
6:12
5:12
6:12
without battens
Profiled
Prohibited
4:12
6:12
6:12
4:12
6:12
Tile
without battens
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall
be utilized during loading and installation of tiles. . •' • •.
. . .... ......
10. Care should be taken during the loading procedure to keep foot traffic to a minimum grad to !void dooppisig of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loi#ingprocedure —Gt;vo tiles• • • • •
laid perpendicular to slope followed by a maximum four tile stack parallel to the slop8,'fet total of 60tiles — fjr: ...
all underlayments except Polystick MTS which shall be loaded onto battens. • • • • • • •
a
0
U)
N
I
i LA-1
POL'anCKTU Plus
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 6 of 8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 1 I gauge ring shank type, applied with a minimtyn 1 Y8" metal.4ijias
required in Miami -Dade County or simplex type nail as otherwise allowable in other Ngibnr, at a rainirryWm rate . •
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail aralerea para cWar" on...%
the face of membrane, with the above stated nails and/or disks. The head lap membrane• s to cover the area bei,
back -nailed. (Please refer to applicable local building codes prior to installation.) ." •. •
.... . .. .....
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.... ....
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Pofyg;lass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium Mr Ftasbing 4megt,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement,applie41818'etween.
the application of the lap. The use of mastic between the laps does not apply to PolysticAkS. • • : * 0
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes of TVI T' or greater. It is suggested that on pitch/slopes in excess of 6 '/4"/12", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 7 of 8
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
. .
....
......
......
..
......
....
. ..
.....
......
....
.....
....
.. .
......
. .
. .
......
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 8 of 8
Mlatla>�olao�
a
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA
GAF
1 Campus Drive
Parsippany, NJ 07054
SCOPE:
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 315-2599
www.miamiclade.eov/economy
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida 11 jil4ing Code
including the High Velocity Hurricane Zone of the Florida Building Code. • �... • • �„
...... .. ......
DESCRIPTION: VersaShield® Fire -Resistant Roof Deck Protection and VersaShieWo %o1oTM Fire -Resistant
Slip Sheet • • • • • • • w
.
.... w ww wwwww
LABELING: Each unit shall bear a permanent label with the manufacturer's name or loge»city, stab ano•followirr 0 • -
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein' "' • ; •
•wwwww w
RENEWAL of this NOA shall be considered after a renewal application has been filed aqd there has Jeentld change
in the applicable building code negatively affecting the performance of this product. .. . w • %
w
ww •
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-1022.26 and consists of pages 1 through 3.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 16-1216.02
Expiration Date: 02/07/22
Approval Date: 02/02/17
Page 1 of 3
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: Fiberglass
SCOPE:
This acceptance is for VersaShield® Fire -Resistant Roof Deck Protection (a.k.a "VersaShield® Underlayment") and
VersaShield® SoIoTM Fire -Resistant Slip Sheet (a.k.a "VersaShield SoIoTM"), as described in this Notice of Acceptance,
for use with approved prepared roof assemblies. Designed to comply with the Florida Building Code and the High
Velocity Hurricane Zone of the Florida Building Code.
PRODUCT DESCRIPTION:
Manufactured by
Applicant Dimensions
VersaShield® Fire- 42" x 100' rolls
Resistant Roof Deck
Protection
VersaShield® SoIoTM 72" x 166.7' rolls
Fire -Resistant Slip Sheet 36, x 166.7' rolls
MANUFACTURING LOCATION:
1. Conover, NC
EVIDENCE SUBMITTED:
Test Azency
PRI Construction Materials
Technologies
Underwriters Laboratories Inc
Test Product
Specifications Description
ASTM D 226 Non -Asphaltic fiberglass -based underlayment
Type II and/or fire barrier.
UL790
Test Identifier
GAF-270-02-02
GAF-748-02-01
ELK-063-02-01
99NK45831
1 ONK 11990
R19254
08CA37926
08CA49140
Non -Asphaltic fiberglass -based slip sheet and/or
fire barrier.
•
• • •
••••••
•• ••••••
6089
•.....
••Y•
• •• •••••
••••••
• •
•••• •••••
Test Name/Repor't• • •
• • Date • • • • • •
ASTM D 226
;••�•*
go
TI/15/10...600
ASTM D 226.
; • • f 2t12/ 16+
TAS 100
•.+• :
•
••09/27/01:••••:
UL790
• • • a3%21 /00
UL790
05/18/11
ASTM D 226
09/13/01
UL790
09/23/09
INSTALLATION:
1. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoIoTM Fire -Resistant Slip Sheet shall be
installed in strict compliance with applicable Building Code.
2. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® Solo TM Fire -Resistant Slip Sheet shall be
installed with a minimum 4-inch head lap in a shingle layer fashion.
3. VersaShield® Fire -Resistant Roof Deck Protection shall be mechanically fastened with approved fasteners in
compliance with Florida Building Code 1518.2 when used in lieu of a code prescribed ASTM D 226 Type II
underlayment.
NOA No.: 16-1216.02
Expiration Date: 02/07/22
Approval Date: 02/02/17
Page 2 of 3
LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire
ratings of this product
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. VersaShield' Fire -Resistant Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30
days of application. VersaShield® Solo TM Fire -Resistant Slip Sheet shall not be left exposed to the weather.
4. VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® SoIoTM Fire -Resistant Slip Sheet are a
component used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance.
5. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoIoTM Fire -Resistant Slip Sheet may be used
with any approved roof covering Notice of Acceptance listing. VersaShield' Fire -Resistant Roof Deck Protection
or VersaShield' SoIoTM Fire -Resistant Slip Sheet may be used as a component part of an assembly in the Notice of
Acceptance. If VersaShield' Fire -Resistant Roof Deck Protection or VersaShield' SoIoTM Fire -Resistant Slip Sheet
is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product
Control Department for approval provided that appropriate documentation is provided to detail compatibility of the
products, wind uplift resistance, and fire testing results.
6. VersaShield' Fire -Resistant Roof Deck Protection and VersaShield® SoIoTM Fire -Resistant Slip Sheet are a non -
asphaltic underlayment that may be used as a fire barrier for prepared roof assemblies. For fire classification of
specific roof assemblies using VersaShield' Fire -Resistant Roof Deck Protection or VersaShield' SoIoTM Fire -
Resistant Slip Sheet refer to a current Approved Roofing Materials Directory for fire ratings of this product.
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Buil(ipp.Code and
Rule 61 G20-3 of the Florida Administrative Code. . '.... • • • • • • •
.
... ... . .
LABELING: """ " ""'•
All membranes or packaging shall bear the imprint or identifiable marking of the manufact mw'scame o6Jogo, city Atr*
state of manufacturing facility, yellow line to identify the ASTM Standard designation or loV,-A the ;616 ng ••�•••
statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County PrttMtf rontr4l'&"oasGo • • • • •
00
shown below. .
.....• • •
MIAMI•DADE COUNTY • • • • • •
'
.
...� ..i •. • �....:
.• •
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by Building Official or Applicable building code in order to properly evaluate the
installation of this material.
END OF THIS ACCEPTANCE
NOA No.: 16-1216.02
Expiration Date: 02/07/22
Approval Date: 02/02/17
Page 3 of 3
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Date: 7/31 /2018
Permit No: RF-7-18-2004
Planning Critique
NEEDS COLOR SAMPLE AND REFLECTIVITY PERCENTAGE.
Travis Kendall
305-762-4864
Plan review is not complete, when all items above are corrected, we will do a complete
plan review.
If any sheets are voided, remove them from the plans and replace with new revised
sheets and include one set of voided sheets in the re -submittal drawings.
'Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Date: 8/1 /2018
Permit No: RF-7-18-2004
Building Critique Review
1. Zoning approval required.
Ismael Naranjo
Building Official
Plan review is not complete, when all items above are corrected, we will do a complete
plan review.
If any sheets are voided, remove them from the plans and replace with new revised
sheets and include one set of voided sheets in the re -submittal drawings.