RF-02-19-406Permit NO.: RF-02-19-406 Miami Shores Village DPermit Type: Roof 10050 NE 2 Ave Miami Shores FL33138 Work Classification: Flat 305-795-2204 PermStatuS: Approved Issue Date:02/21/2019 Expiration: 08/20/2019 Location Address Parcel Number 42 NE 96TH ST, Miami Shores, FL 33138 1132060130640 Contacts PETER GIORGI Owner J&K ROOFING INC Contractor 1221 SW 14 ST, MIAMI, FL 33145 DONNIE HERRON Other: 3059841767 SAME AS ABOVE Business: 9549617663 Description: RE -ROOF 400 SOFT FLAT WITH CAPSHEET Valuation: $ 7,000.00 Inspection Requests: 305-762-4949 Total Sq Feet: 400.00 Fees Amount Application Fee - Other $50.00 CCF $4.20 DBPR Fee $3.75 DCA Fee $2.50 Education Surcharge $1.40 Roofing Fee $200.00 Scanning Fee $9.00 Technology Fee $6.25 Total: $277.10 Building Department Copy Payments Date Paid Amt Paid Total Fees $277.10 Check # 35411 02/21/2019 $277.10 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify regulating construction an5zoninc all the foregoing information is accurate and that all work will be done in compliance with all applicable laws hermore, I authorize the above named contractor to do the work stated. rlyD 41erro'j Authorized Signature: Owner / Applicant / Contractor / Agent Date February 21, 2019 Page 2 of 2 BUILDING PERMIT APPLICATION Miami Shores Village R E C 1 V E D Building Department FEB 21 2m 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 T I INSPECTION LINE PHONE NUMBER: (305) 762-4949 �J FBC 201-7 Master Permit No. Sub Permit No. ❑BUILDING ❑ ELECTRIC Q ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL [—]PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP / �%/ CONTRACTOR DRAWINGS JOB ADDRESS: -1� A)C: G � 5* City: Miami Shores County: Miami Dade Zip: 3 Folio/Parcel#: is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: /� FF,E: OWNER: Name (Fee Simple Titleholder): A �ei- 6(4/ I Phone#: 3o_r m Address: L N6- 6 S r City: Al C_ 51 D State: n Zip: � 3 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: -�_( Phone#: Address: S�PrAA G A J City: ' f State: �/ Zip: 33v� O Qualifier Name: Ao/L✓l, e t t2! f0 •� n Phone#: State Certification or Registration #: CC' C © Certificate of Competency #: DESIGNER: Architect/Engineer: Address: City: State:`` Zip: qValue of Work for this Permit: $ ���� Square/Linear Footage of Work: o-0 Type of Work: ❑ Addition ❑ Alteration �t ❑ New Repair/Replace ❑ Demolition 'OB 7 71%� Sy f/� r T �� W� C4/�SK �P4 Description of Work: Ae✓ Specify color of color thru tile: Submittal Fee $ Scanning Fee $ Technology Fee $_ Structural Reviews $ (Revised02/24/2014) Permit Fee $ Radon Fee $ Training/Education Fee $ CCF $ DBPR $ CO/CC $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ _ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this oZ day of G� 20 JF—, by c Iof ` 7" CI 0f G i ,who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: C�✓� ��I The foregoing instrument was acknowledged before me this N day of �G 20 by Qpn.a ( Ae rm J who is personally known to -------------- me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Print: ., NOTARY PUBLIC y Cristobal Ortiz Seal: o STATE OF FLORIDA Seal: ��o , NOTARY PUBLIC Comm# FF920230 ® STATE OF FLORIDA 't,ptlw Exoires 11/13/2019 Comm# FF920230 APPROVED BY y/ , Plans Examiner Zoning as Structural Review Clerk (Revised02/24/2014) 2/18/2019 Property Search Application - Miami -Dade County �. r.OFFICE OFT HE PROPERTY APPRAISER Summary Report Property Information Folio: Property Address: 11-3206-013-0640 42 NE 96 ST Miami Shores, FL 33138-2724 Owner PETER A GIORGI Mailing Address 42 NE 96 ST MIAMI, FL 33145 USA PA Primary Zone 1100 SGL FAMILY - 2301-2500 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 4/3/1 Floors 1 Living Units 1 Actual Area 3,429 Sq.Ft Living Area 2,493 Sq.Ft Adjusted Area 3,001 Sq.Ft Lot Size 10,725 Sq.Ft Year Built 1948 Assessment Information Year 2018 2017 2016 Land Value $267,952 $267,952 $267,952 Building Value $347,053 $193,761 $194,047 XF Value $4,342 $2,336 $2,366 Market Value $619,347 $464,049 $464,365 Assessed Value $619,347 $464,049 $464,365 Benefits Information Benefit Type 2018 2017 2016 Homestead Exemption Homestead Exemption E$25,000Second 5,0 00 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 1 AMD PB 10-70 LOT 7 & W1/2 LOT 6 BLK 5 LOT SIZE 75.000 X 143 CF 73R126457 Generated On : 2/18/2019 Taxable Value Information 2018 2017 2016 County Exemption Value $50,000 $0 $0 Taxable Value $569,347 $464,049 $464,365 School Board Exemption Value $25,000 $0 $0 Taxable Value $594,347 $464,049 $464,365 City Exemption Value 1 $50,000 $0 $0 Taxable Value 1 $569,347 $464,049 $464,365 Regional Exemption Value $50,000 $0 $0 Taxable Value 1 $569,347 $464,049 $464,365 Sales Information Previous Sale Price OR Book -Page Qualification Description 12/19/2017 $880,000 30806-1185 Qual by exam of deed 06/09/2015 $550,000 29677-3358 Qual by exam of deed 06/01/1973 $80,000 00000-00000 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at hftp://www.miamidade.gov/info/disclaimer.asp Version: LICENSED AND INSURED LICENSE # CC-0058051 2010 Sherman Street Hollywood, Florida 33020 ROOFIN6 SMV&". SM9 *9&Uda ,Ion 000% 30 ZtMU 954-961-7663 954-961-9879 Fax 954-925-8015 Submitted To Job Name Date Street 40-1 l,�" , Street Phone 1 20 Gl l7� City, St. & Zip City, St. & Zip Phone 2 p ,y Legal Lot Blk sub Tax Folio# ALL ROOFS TO BE DONE AS FOLLOWS ❑ SLOPE ROOFH'FLAT ROOF ill tear off entire existing slope Roof down to deck or Smoot Will tear off entire existing flat roof down to deck or smooth wor ble surface. WILL RENAIL DECKING TO MEET EXIS G workable surface. WILL RENAIL DECKING TO MEET EXISTING CODE. Remove all related roofing deb 's from premises. CODE. emove all related roofing debris from mises. Replace any necesspry rotten wood, LF, or Sq. ft for Replace any ecessary wood, LF, or S for plywood plywood free.pe ft. thereafter. S free. p ft. thereafter. Will apply 1 ply of basesheet anchored to the deck according to local building code. Using HOT ASPHALT, will Will apply 30 lb. pre 'um felt, anchored a deck according to local mop l/plys of fiberglass felts to said basesheet. Install all new building code. Will install a ew met ashing and lead stacks. USING metal flashing and lead stacks. HOT ASPHALT, MOP A 36 H WIDE STRIP OF 30 LB. FELT t VERTICALLY AND A 16 1 WI GALV. VALLEY METAL IN ALL ef/using HOT ASPHALT mop 1 ply fiberglass cap VALLEYS. sheet to said fiberglass Will NAILfibergl s shingles wit 'ngshanks ❑Using HOT ASPHALT, mop 1 ply MODIFIED nails (choice of rand &color) BITUMENT to said fiberglass felt. Man cturer warranty on shingles. ❑ Will flood coat with hot asphalt and embed pearock. We hereby propose to furnish labor and materials - complete in accordance with the above specifications, for the sum of dollars ($ &4re ) with payment to be made as follows: No carpentry work, woodwork or painting unless specifically stated in this contract. In the event payment is not make as stated in payment schedule, All fees incurred in collections, such as, but not limited to, attorney fees, court costs and collection agencies, are to be paid by signer or owner. COVERAGE The roof applied to the building described above is guaranteed for / ?4 years from the date of completion upon final payment in full. This guarantee is TRANSFERABLE AT NO CHARGE to new owners of the property. Under this guarantee, the roofing contractor will, at its own expense, make any repairs necessary to correct roof leaks resulting from the following causes: 1. Failure of roofing felts or base flashing resulting from usual and ordinary effects of wear and weather. 2. Poor workmanship of roofing contractor in applying roofing and flashing materials. Method f Pa yme t: []CHECK EXCLUSIONS '�� ❑ CASH ❑ MONEY ORDER This guarantee does not cover. C�� g ��'�� CREDIT CARD 1. Leaks or other damage caused by: a. Natural disasters, including but not limited to floods, lightning, hurricanes, hail, windstorms, earthquakes, tornados, dry rot, etc. b. Structural failures such as cracks in decks, walls, partitions, foundations, windows, stoppage of roof drains or gutters, etc. c. Changes in the original principal usage to which of the building, unless approved by the contractor in advance in writing. d, Erection or construction of any additional installation on or through the roofing felt after the date of completion. e. Roof or flashing repairs by others, painting or coating without approval. f. Riots or vandalism. g. Termites or other insects. h. Penetration of the roofing from beneath by rising nails. 2. Damage to the building or it's contents, roof insulation, roof deck or other base over which roofing felt is applied. ACTION In the event leaks from roofing should occur, owner shall notify contractor promptly. Contractor will inspect the roof, and if cause of leak is within the coverage as stated above, the contractor will arrange for repairs to be made at no cost to the owner. If cause of leak is not covered, contractor will not be responsible for cost of any repairs. In the event leaks are not covered under the terms of this guarantee, a service charge will be invoiced to the owner. The guarantee will become null and void if payment of the service charge Is not made within 30 days of the billing date. WE MAKE NO GUARANTEES OF ANY KIND, EXPRESSED OR IMP ,EXCEPT AS STATED HEREIN. ACCEPTANCE OF PROPOSAL: The above prices, specifications SII NAURE ( Owne) and conditions are satisfactory and are hereby accepted. You are SIGNATURE (Owner) authorized to do the work as specified. Payment will be made as outlined above. I understand wood clause. Authorized Signature DATE e5 100% RECYCLABLE CREATIVE GRAPHICS • 954-962-8868 jac& rwonngi rrupubai vuvo ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) RECEIVED High -Velocity Hurricane Zone Uniform Permit Application Form FEB 21 2019 1 Section A (General Information) 1 ter i o. _r Process No. 1 Cont e 1 Job Add r oZ / JC 1 ROOF CATEGORY 1 Low Slope 1 l Pe ❑ Mechanically Fastened Tile ElMortar/Adhesive Set Tiles ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shaly2s• • • . 1 ❑ Prescriptive BUR-RAS 150 1 "" •'0':' . . ROOF TYPE ...... ' ' .. ' .....E ❑ Reroofing 0 Rec�pyeripg New roof ❑ Repair ❑ Maintenance """ :....L 0.0 ROOF SYSTEM INFORMA ON ' Low Slope Roof Area (SF) 300 Steep Sloped Roof AREA (SSF) ✓ 000000 T al .( j-D rJ 0 ...... . . Section B (Roof Plan) 0 • Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and iwdlow drain;. Include dirrlbn- 0 i • sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. '.,..' 1 1 �r 1 1 - I I - 1- 1 E7- - - - 1 r -�D arrri S�icres Village i - - - `Af"OWED - - _ SY -DATE 1 ZONINGDEP=f . 1 -- - BLDG DE0T — - _ 1 St'BJFCT 1'0 CCNIPUANCE WI r}-i ALL FEDERAL 1 - 1 In"S J ri - tui .. _. ;1 1 1 FLORIDA BUILDING CODE — BUILDING, 6th EDITION (2017) 469 Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof Systeml Fill in Specific Roof Asseatbly Components and l kmft Manuftcturw (If a corrtporterrt is not used, Werdiry as'NAJ System INarrufar trsec `I 4 NOANo- I - 0 19, 07 Fadww Spates for Ancl wfilase Sheet Athichment Field: ' oc ® Lop. # Rows oc Perimeter: -&—' or. 0 Lap, # Rows ' oc Design wind Pressures, From RAS 128 or Calculations: .Comm: �' oc Lap. #Rows ' oc c Pmeotl: `fa Pme ?I.7 Pmex3 �j• is Number of Fasteners Per Insulatlon Design PresstFrom the Specific NCIA Mw rt+e, s Deck Type: 1VQDd sly'` Y4jai( An hodBase Sheet S No. of PMs): AnchorMase Sheet FasterwSonding Maul: iron Base Layer. - Base irulation size and Tiftwo s: Base Iron Fastgrer8ont" Materiat Top Insulation layer: Top Iron St w and Thidaress: Top Insulation FasierrerlBor>dirg Material: Pi/t/i Field Perimeter Comer Illustrain Components Noted and Detalls as Applicable: Woodbiocidrrg. Gutter, Edge Termination ..... Stripping, Flashing, Continuous. Cleat, Carr.... • Strip. Base Flashing, Countdr.. • F{bshin%. Coping, Etc. . • • • • • . . • Indicate Mean Roof HeWK PampOt Height, Height of Base Flashing, Componat Material. Material Thidmess, Fastener T". Fbstendt Spacing or SWm* Manufacture% that . Comply with RAS III and ChapteC j d, . • • • • • • Q, `w �43 N Base Sheet(b) & No. of Piy(sr 7S Agse Aee4- Ply Shests)A No. of Ply(s): 2,Q 14 'S Plypf Fps. �T I jL TopPnr-17erQ1t,S5 Cc�pS �CP T Top F # Material: r r MIA DUAN I DADE COUNTY PRODUCT CONTROL SECTION 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 118hl SW 26 Street, Room Miami, Florida 33175-2474474 BOARD AND CODE ADBUN STRATION Dr rWON T (786P 15-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.mhwddad"ov/emnomv 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable riles and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AM). 000000 . ........... This NOA shall not be valid after the expiration date stated below. The Miami Dade CoMty Product' . • . • . DAM . . .. ...... Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade �'ounty) . reserve the right to have this product or material tested for quality assurance purposes. Xtpa produgtor material fails to perform in the accepted manner, the manufacturer will incur the expense of such teWg.' ..... and the AHJ may immediately revoke, modify, or suspend the use of such product or matwW within their • • • •' jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Mim�-Dade County * ...... Product Control Section that this product or material fails to meet the requirements of toe Wbcable building code. Goo*:* This product is approved as deseribed herein, and has been designed to comply with the Morida Buddialf Code ' including the High Velocity Hurricane Zone of the Florida Building Code. "" DESCRIPTION: GAF Conventional Built Up Roof Systems for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "MmmiDade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TER MEMATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECITON: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-1030.01 and consists of pages 1 through 27. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.:18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 1 of 27 W Membrane Type: BUR Deck Type 1I: Wood, Non Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank seemed 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(3): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: TOPCOAT FireOut7 Fire Barrier Coating, VersaShiel& Fire -Resistant Slip Sheet or (optional) VersaShield® Solo Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Anchor sheet GAFGLAS® #75 Base Sheet, Tri Ply® #75 Base Sheet, Ruberoid® 20 Smooth or GAFGLAS® Stratavent® Venting Nailable Base Sheet is secured as described below. Fastening Miami Dade County Approved min. 12 ga. annular ring shanlCmijs and mitt.•? 5/8 in. • • • • ; • Option ft diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide and}for dheet st& l* and 8 • . in.. o.c. in the field of the sheet in two staggered rows. ***:so • • • • • • (Maximum DesiL►n Pressure —45 nsf See General Litnitation•�7J• .. ; • • • • Fastening Miami Dade County Approved min. 12 ga. annular ring shank AM and min. f M in. • • • • Option #2: diameter tin • • • • • • • p ' caps are spaced 6 in. o.c. in the min 4 in. wide an��ie � �lseet siSle�iaps and Ct • • • • in. o.c. in the field of the sheet in two staggered rows. aximunt Design Pressure: 525 psf. See General Limitation #7j ....:. Fastening Drill Tce #14 Fasteners and Drill Tec"` 3 in. Standard Steel dates .-Drill ; ec ; • ; • • • • Option #3: AccuTrade Flat Plates or Drill-Tec` 3 in. Ribbed Galvalume Plate (Flat) a% Spaded 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maodmum Design Pressure: 52.5 psf. See General Lu niiadon #7) Fastening Drill Tec` #14 Fasteners and Drill -Tee"' 3 in. Standard Steel Plates, Drill -Tee Option #4: AccuTiae Flat Plates or Drill -Tee 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure:—60psf. See General Limitation #7) Fastening Drill-Tec— #14 Fasteners and Drill-Tec7 3 in. Standard Steel Plates, Drill-Tec" Option #5: AccuTrac® Flat Plates or Drill -Tee 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maxvnum Design Pressure: —97.5 psf. See General Limitation #7) Ply Sheet: When optional cap sheet is present: or more plies of GAFGLAS® Plv 4, TriPlye' Ply 4, GAFGLAS®Flex Ply 6 adhered in a full mopping of hot asphalt applied at 20-401bs./sq. installed per manufacturer's installation mstruchons. When optional cap sheet is not present: Three or more plies of GAFGLAS® Ply 4, Tri-PlyO Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 20-40 lbsJsq. installed per manufacturer's installation instructions. NOA No.i 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 23 of 27 Cap Sheet: (Optional) GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS EnergyCap ced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbsJsq. installed per manufacturers ' installation mst uct ons. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbsJsq. and 300 lbsJsq. respectively in a flood coat of approved asphalt at 60 lbsJsq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 galJsq. OR Topcoat® MB Plus applied at 0.5 to 0.75 galJsq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 galJsq. 3. Fiber Aluminum Roof Coating. • • • • . . .... ...... Maximum Design • Pressure: See Fastening Above. ...... . .. ...... .... . .. ..... ...... . . ..... .. .. . ...... . . . . ...... NOA No.:18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 24 of 27 WOOD DECK SYSTEM LEWTATIONS: 1 A slip sheet is required with GAFGLAS* Ply 4 and GAFGLAS® Flex Ply 6 when used as a mechanically fastened base or anchor sheet_ 2. Minimum '/4" DensDeck' Roof Board or %:" Type X gypsum board is acceptable to be installed directly over the wood deck GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment When applied in approved asphalt,.ganel size shall be 4' x 4' maximum. • . . .... ...... 4. An overlay and/or recovery board insulation panel is required on all applications over closed ;ell fonilsylations • when the base sheet is fiilly mopped If no recovery board is used the base sheet shall be Alba using sJJIbt • • •"' mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" nbbdli§'I'three rows, one at ...... each sidelap and one down the center of the sheet allowing a continuous area of ventilation %ncircft* * *the , strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow ' p * atiou ASS Y� Asphalt ..:..' application of either system shall be at a minimum rate of 12 lbsJsq. Note: Spot attacla<d rj+stems*'sbaVbe ...... limited to a maximum design pressure of -45 psf. ...... 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force value of�7�f , as (F') .... • • tested in compliance with Testing Application Standard TAS 105. If the fastener value,:as fiLjl3 tested, are below ....: 275 lbf. insulation attachment shall not be acceptable. .. ' : . ". 0' 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.:18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 27 of 27 10/18=6 TGFU.R14153- Roofing Systems GAF 1 CAMPUS DR PARSIPPANY, M7 07054 USA TGFU•R14153 Roofing Systems Roofing Systems R14153 "Ruberoid® 20" or "Ruberoid® 20 HT" or'Ruberoid® Modified Base Sheer may be utilized as an alternate to Type G2 base sheets in any of the following Classifications. .... 1/2-in. thick (minimum) gypsum board or 1/4-in. thick (minimum) Georgia-Pacific Gypsum LLC "DensDeck& Roofboard," •ppen�pedc prime' Roofboard' or "DensDeek DuraGuardm Roofboard" may be used in any existing noncombustible deck Classificat%n.'When 11iht9is done, the resulting roofing system is acceptable for use over combustible (15/32-in. thick minimum) roof decks. Howetee, W butt j8ints'ilh the gyWrA board and Georgia-Pacific Gypsum LLC "DensDeck® Roofboard," 'DensDeek Prime® Roofboard" or "DensUeck4X raGuardTM Roofboard' pqy%p6; offset a minimum of 6-In. with the butt joints In the roof deck. If polystyrene is part of the roof system, it mug Jae placedebelow the • • overiayment board. • Multiple plies of "GAFGLAS® Ply a or "Tri-Ply® Ply 4" or "Tri-Ply® Ply 6" may be adhered to Georgia -Pact ell ftm LL: ;Qp4peek 00 0 Roofboard," "DensDec k Prime® Roofboard" or "DensDeek DuraGuard"' Roofboard" In hot roofing asphalt:. • • • • • • . • • • • "EnergyGuardTM Ultra" is an acceptable alternate to 'EnergyGuardm RF" in any applicable Classification. : : • • • • • . • • •••.•• 'GAF StrataventO SiminatorTM Venting Base Sheet (Mailable)' may be mechanically attached or hot mo j • pped.overmonoombustible decks pQd " as a mover over existing roof systems. • • • • • 'GAFGLASO Peritte Insulation" may be utilized as a cover board over "EnergyGuardTM RP insulation in any of the following stys%" Unless otherwise indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or UL Classified urethane insulation adhesive. Polystyrene referenced In arry of the following Classifications Include "EnergyGuardTM EPS Insulation". Unless otherwise indicated, all insulations may be adheres with any UL Classified Insulation Adhesive per the manufacturers installation instructions (excluding LRF Adhesive O) in any applicable Non -Combustible Roof Deck Classifications. References to glass fiber Insulation include 'EnergyGuard Fiberglass Insulation". "EnergyGuard'" Tapered" is an acceptable alternate to "EnengyGuard"" In any applicable Classification ASPHALT FELT SYSTENS W1TH HOT ROOFMO ASPHALT Type G2 asphalt glass mat base sheet ("GAFGLAS® #75 Base Sheer or "Tri-Ply® *75 Base Sheer, or "GAFGLAS® *80 ULTIMA") Is a suitable alternate for Type G1 asphalt glass fiber ply sheet ('GAFGLAS® Ply r or "Tri-Ply® Ply 4", or "GAFGLAS® Ply 6") In the Class A, B or C roof systems Indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet "GAF Stratavent® 91minatorTM Venting Base Sheet (Perforated)" or "GAF Stratavent® Oiminator " Venting Base Sheet (Mailable)." Perforated base sheets to be loose laid or fully adhered with hot roofing asphalt and nallable base sheets are to be mechanically attached granule side down. As an option Type G2 asphalt glass mat base sheet (•GAFGLAS® *75 Base Sheer or "rut -Ply® *75 Base Sheet" or "GAFGLAS® *80 ULTIMA' or "GAF Stratavent® Eliminator'" Venting Base Suet (Mailable)" may be substituted for Type G1 asphalt glass fiber ply sheet ("GAFGLASO Ply 4" or "Tri-Ply® Ply 4" or "GAFGLASO Ply 6") as the nailed base ply in the following systems. Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened. Unless otherwise indicated, all insulations may be hot mopped or mechanically fastened. "GAFGLASO Flashing" or "Ruberoid®" may be used for flashing in any of the Class A, -B or C systems listed below. When "perlite" is referenced, this includes "GAFTEMP PERMALITE®" or any other UL Classified perlite insulation. Crushed stone or slag are suitable alternates for gravel In any of the Class A, B or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C- 15/32 or W— The use of gypsum board under any of the following Class A, B or C systems does net adversely affect the rating. The use of W-in. minimum thick gypsum board is an acceptable alternate for minimum insulation over C-15/32 thick roof decks. The use of polystyrene Insulation board between minimum air. -in. thick periite board and deck with rosin paper (periite/rosin paper/polystyrene/perlite) is a suitable alternate for polyisocyanurate board in the following Class A, B or C systems. Mfp/ldatabase u/.km/og-biNXYVliemplaM USEXT/1FRAME/: wwpageJ nl?name=TGFt1.R141M&co ushoritille=Roofing+ &ol*d=1083885W78d... 1149 10h812016 TGFUA14153- Roofing Systems "EnergyGuard'" RA" or "Tapered EnergyGuard"" RA' or "EnergyGuard", Composite RA" may be substituted for any Atlas Roofing Corp. polyisocyanurate insulation in any of the following Classifications. Trumbull 'Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Not Roofing Asphalt". -GAFGLAS® #80 Premium Base Sheer may be used In any of the following systems. "GAFGLASO Flex Ply 6' and 'Tri-Ply® Ultra -Flexible Ply 6" are suitable alternates to "GAFGLASO Ply 6% "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite In5U1aUon in any of the following NC Classifications. Unless otherwise Indicated, any of the "Asphalt Felt Systems with Not Roofing Asphalt" may be surfaced with "TOPCOAT® Flnrshield MB" at 2% to 3-gal/100-ft2. 'Ruberoid® Dual Smooth' may be used as an alternate to 'Ruberoid® Mop Smooth' or 'Ruberoid® 20' or "Ruberoid® 20 HT". "Ruberold® Mop Smooth 1.5' may be used as an alternate to "Ruberoid® Mop Smooth-. Class A, B and C Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. 'Ruberoid® Heat Weld" SSS roofing membrane may be used in lieu of 'Ruberoid® Mop" SBS products in any applicable Classification. Class A 1. Deck: C-15/32 Incline: 3 • • •••• •••••• Insulation (Optional): —One or more layers perltte or wood fiber or glass fiber or polyisocyanurate'dr urethane l • % • perllte/polylsocyanurate composite Or Periite/urethane composite or wood fiber/polyisocyanun:te Comp&IMbr pheflolld; `any thiclAW • Ply Sheet: — Three or more plies Type G3 or'GAFGLAS@ Ply 4" or "Tri-Ply® Ply r or "GAFGLAS®•Riy 6r hot mopped. • • Suriecing: — Gravel. • .. • • • 0000 2. Deck: C-IW32 0••••0 i 0••0 ••••• Ind�:2 • •••••• • • •••• •• Insuietion (Optional): — One or more layers perlite or wood fiber or glass fiber or poiyisocyanurat 4r11.6 Kane ar • • • • """""• periite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyarwrate Oompositeor phenoliq any thickness. Ply Sheet: — Three or more plies Type GI or 'GAFGLASO Ply r or "Tri-Plyg Ply r or "GAFGLASO P11600. " , ...":. Cap Sheet: — One ply Type G3 OGAFGLASO Mineral Surfaced Cap Sheet" or "Tri-Ply® Mineral Surfaced Chap Shef ""de" GAFG1.44SO . EnergyCap BUR Mineral Surfaced Cap Sheer. " . 000000 •• • • •• • • 3. Deck: NC Income: 2 0 • : • " 0 Insulation (Optkrnaq: — One or more layers periite, wood fiber, glass fiber, polyisocyanurate, urethane, periite/polyisocyanurate composite, perlite/urethane composite, wood fiber/polyisocyanurate composite, phenolic, 2-in. maximum. Ply Sheet: — Two or more plies Type G1 "GAFGLASO Ply 4", "Tri-Ply® Ply 4" or "GAFGLASO Ply 61. Cap Sheet: — One ply Type G3 'GAFGLAS® Mineral Surfaced Cap Sheet' or "Tri-Ply® Mineral Surfaced Cap Sheet' or "GAFGLASO EnergyCap•" BUR Mineral Surfaced Cap Sheet C-15/on e: ne: 1 SNp Sheet (Optional): — Red rosin paper, nailed to deck. I nubitlon (Optional): — Any thiduiess perlite or wood fiber or glass fiber or polylsocyanurate mechanically fastened or adhered with OMG Inc "OlyBond Fastening System" or any UL Classified insulation adhesive. Dam Sheet: — �_ s.l'rY- no G2 -ten_ F-5-� •`" 9 r+ or 'Tri-Ply® *75 Base Sheet" (may be nailed). Ply Sheet: — Ong or more plies Type G3 "GAFGLAS PI 4' or "Tri-Ply® Ply 4' or GAFGLAS®`PtQ'S'^'— Cap Sheet: — One ply Ol3^iN�_i cal Surface Cap Sheet' or "Tri-Ply® Mineral Surfaced Cap Sheet" or 'GAFGLASO EnergyCapTM BUR Mineral SurraCe Cap Sheet". Surfheinp (Optk►na* — 'TOPCOAT® BWWCote— Elastomeric Coating" applied at a rate of 2-gal/100-ft2. S. Deck NC Incline: 3 Base Sheet: — One ply Type G2 'GAFGLASO #75 Base Sheet' or'Td-Ply® #75 Base Sheet". Ply Sheet: — One or more plies Type G1 "GAFGLASO Ply 4" or'Tri-Ply® Ply 4" or "GAFGLAS® Ply 6% Cap Sit: — One ply TYpe G3 "GAFGLASO Mineral Surfaced Cap Sheet" or'Tri-" Mineral Surfaced Cap Sheer or "GAFGLASO EnergyCapTM BUR Mineral Surfaced Cap Sheet' 6. Deck C-15/32 Udine: 2 Insulation: — One or more layers perlite, glass fiber, polylsocyanurate, urethane, periite/polyisocyanurate composite, perlite/urethane composite, phenolic, 1 in. minimum (offset a minimum of 6-in. from plywood deck joints). Base Sheet: — One or more plies Type G1 or Type G2 or Type G3. Membrane: — One or more plies "Ruberoid® Torch Smooth' or "Ruberoid® Torch Granule" or "Ruberoid® Torch Granule Plus" or "RuberoidO Mop Smooth" or'Ruberoid® Mop Smooth 1.5' or "RuberoidO Mop Smooth Plus" or "Ruberoide Mop Granule" or "Ruberoid® Mop Plus Granule" or "ROOFMatc m SBS Modified Granular" or "Tri-Ply® SBS Modified Bitumen Membrane" or "ROOFMatchT" APP Modified Granular" or'Tri-Ply® TP-4G" or'Tri-Ply® TP-4" or'RuberoidO Dual Smooth'. Cap Sheet: — Type G3 "GAFGLASO Mineral Surfaced Cap Shen' or "Tri-Ply® Mineral Surfaced Cap Sheeror "GAFGLASO EnergyCap"" BUR Mineral Surfaced Cap Sheer fully adhered with hot roofing asphalt 7. Deck: C-15/32 hip IdWabessitconical-bNXYVANnOabelLl3E MIlFRAMEkhawpegeJtml? a wTGFUR14153&ccrehordide=RoolrWSysiemWka4id=1083f85E07&d .. 2M9 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category BUR Material: ,Fiberglass Deck Type: Wood Maximum Design Pressure: -97.5 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description GAFGLAS' Ply 4 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced Wide with fiberglass mat. Tri-Ply' Ply 4 39.37" (1 meter) ASTM D2178 000000 Smooth surfaced asphaltid pl3 sleet reinforced • • • • • Wide with fiberglass mat. ...... ' ..' ....:. GAFGLAS' 39.37" (1 meter) ASTM D2178 Smooth surfaced asphaltic p13rheet reiaforced • F1exPly'" 6 Wide with fiberglass mat. ' . • .. 'a : .. • • • . • • GAFGLAS' #75 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or baSelpfy sheWroeol iforced• • • • • • Base Sheet Wide with fiberglass mat. ...... . .' Tri-Ply' #75 Base 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply she&YeMforced. • 0 0 . Sheet Wide with fiberglass mat. '..' .. :"": GAFGLAS' #80 39.37" (1 meter) ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced Ultima7' Base Sheet Wide with fiberglass mat. GAFGLAS' 39.3T' (1 meter) ASTM D4897 Smooth surfaced asphaltic perforated venting base Stratavent® Wide sheet reinforced with fiberglass mat. Perforated Venting Base Sheet GAFGLAS' 39.37" (1 meter) ASTM D4897 Smooth surfaced asphaltic nailable venting base Stratavent'Nailable Wide sheet reinforced with fiberglass mat. Bottom side Venting Base Sheet surfaced with granules. Ruberoid® 20 39.37" (1 meter) ASTM_D6163 SBS polymer -modified asphalt base or Smooth Wide anchor sheet reinforced with a fiberglass mat. Ruberoid' Mop 39.37" (1 meter) Smooth wide Ruberoid® Mop 39.37" (1 meter) Smooth I:5 wide Ruberoid' Mop 39.3T' (1 meter) Plus Smooth wide Ruberoid' HW 25 39.37" (1 meter) Smooth wide ASTM D6164 Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. ASTM D6164 Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. ASTM D6164 Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. ASTM D6163 Smooth surfaced torch applied SBS base or anchor sheet reinforced with a fiberglass mat. rtuw►Fo�►pe courrr�r NOA No.: 18-0919.07 JAPPROVEDI Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 2 of 27 ' TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT: TABLE 1 Product Ruberoid® HW Smooth GAFGLAS® Mineral Surfaced Cap Sheet Tri-Ply® BUR Granule Cap Sheet GAFGLAS® EnergyCap' Mineral Surfaced Cap Sheet Topcoat® Surface Seal SB Topcoat® Membrane Topcoat® MB Plus Topcoat® FireOut' Fire Barrier Coating VersaShield® Fire - Resistant Roof Deck Protection Test Dimensions Specification 39.37" (1 meter) wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 5 or 55 gallons Product Description ASTM D6164 Smooth surfaced torch applied SBS base or anchor sheet reinforced with a polyester mat. ASTM D3909 Granule surfaced asphaltic cap sheet reinforced with fiberglass mat. ASTM D3909 Granule surfaced asphaltic cap sheet reinforced with fiberglass mat. ASTM D3909 ASTM D6083 1, 5 or 55 gallons ASTM D6083 5 or 55 gallons 5 or 55 gallons 12" x 100' rolls VersaShield® Solo' 42" roll wide, 100 Fire -Resistant Slip ft. Sheet Proprietary Proprietary ASTM D226 ASTM D 146, D828, D4869, D6757 Topcoat® 1, 5 gallons or TAS 139 F1exSeali°' 1 qt. tube Granule surfaced asphaltic cap sheet reinforced with fiberglass mat. Cap sheens factory ggg'ted with TOPCOAT® EnergyEpjr :FlastQMerig Coating. ...... 00.0 ...... . Solvent -based thermoplastic j*ber .. sealant designed to protect audiestoreeged-roof surfaces and to increase roofo cftectivity, . . ; Water -based elastomeric cgatittigr . . . ...... Water based, low VOC prhnef designed toblock asphalt bleed -through. .. • Low VOC, water based fire barrier coating. Non -asphaltic, fiberglass reinforced underlayment and/or fire barrier Non -asphaltic, fire resistant fiberglass underlayment Solvent -based elastomeric sealant. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 3 of 27 APPROVED INSULATIONS: TABLE 2 Manufacturer Product Name Product Description (With Current NOA) EnergyGuard7 Polyiso Polyisocyanurate foam insulation GAF Insulation EnergyGuare Tapered Polyisocyanurate foam insulation GAF Polyiso Insulation EnergyGuard' Ultra Polyiso Glass -faced polyisocyanurate foam insulation GAF Insulation EnergyGuard' RA Polyiso Polyisocyanurate foam insulation GAF Insulation .... EnergyGuard' RA Composite Polyisocyanurate foam insulation with high ***GAF****** Polyiso Insulation Y density fiberboard or permalite • • • • • • EnergyGuard' RH Polyiso Polyisocyanurate foam insulation ...... . .. • • • • •'GAF ...... :....: Insulation • • • • • • • EnergyGuard7 RH Tapered Polyisocyanurate foam insulation .... . .. • • • • • � ' ..... ""' Polyiso Insulation • • • • • • • • • • EnergyGuard" RN Polyiso Polyisocyanurate foam insulation 'rAF • • • """ Insulation • EnergyGuard' Perlite Roof Perlite insulation board GAF • • • • Insulation EnergyGuard' Perlite Recover Perlite recover board GAF Board Securock® Gypsum -Fiber Roof Gypsum board United States Gypsum Corp. Board Securock® Glass -Mat Roof Glass faced gypsum board United States Gypsum Corp. Board Structodek® High Density Fiber High density fiberboard Blue Ridge Fiberboard, Inc. Board Roof Insulation DensDeck' Prime Roof Board Gypsum board Georgia-Pacific Gypsum LLC DensDeck' Roof Board Gypsum board Georgia-Pacific Gypsum LLC L QFILlIbLID) M� APPROVED NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 4 of 27 APPROVED FASTENERS: Fastener Product Number Name 1. Drill-Tec' #12 Fastener 2. Drill-Tec' #14 Fastener 3. Drill-Tec' ASAP 3S 4. Drill-Tec' 3" Steel Plate 5. Drill-Tec'" 3" Standard Steel Plate 6. Drill-Tec' AccuTrac® Flat Plate 7. Drill-Tec' AccuTrac® Recessed Plate 8. Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) APPROVED TABLE 3 Product Description Phillips head, modified buttress thread, pinch point, carbon steel fastener for use in steel or wood decks. With CR-10 coating. Available with a pinch point or drill point. Truss head, self -drilling, pinch point, high thread fastener for use in steel, wood or concrete decks. Drill-Tec' #12 Fastener with Drill-Tec' 3" Standard Steel Plate. Round Galvalume® steel stress plate with reinforcing ribs and recessed for use with Drill-Tec' fasteners. Galvalume® coated steel stress plate for use with approved Drill-Tec' fasteners. A2-SS aluminized steel plate for use with Drill-Tec' fasteners. Galvalume® steel plate with recess for use with Drill- Tec' fasteners. Round Galvalume® plated steel stress plate with reinforcing ribs for use with Drill-Tec' fasteners. Dimensions #12 x 8" max. length, #3 Phillips head. Manufacturer (With Current NOA) GAF # 14 x 16" GAF max. length • • • • #3 Phillips head. • ...... . .. ...... See •••••• GAP ;....; components. .... . .. ..... ...... . . ..... 3" Round ••'••' �AF♦• •••••• . • . . •♦••♦• • • ••..•. 3" Round GAO; • 0 3" square; GAF .017" thick 3" square; GAF .017" thick 3" Round GAF NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 5 of 27 EVIDENCE SUBNHTTED: Test Agency Test Identifier Description Date Factory Mutual Research Corp. 3014547 4470 05/22/03 3029832 4470 05/11/07 3033135 4470 11/24/08 3034312 4470 04/09/09 3036980 4470 08/14/09 3038278 4470 11/18/11 3040738 4470 11/16/10 3041769 4470 05/26/11 3042887 4470 11/14/11 3042905 4470 01/10/12 3046081 4470 02/13/13 3046388 4470 .... •..99r24/12...... 3047636 4470 •..• .. 08/08/13 .' ODOA8.AM 4470 ...... '9;%9/99• • • •: • OD lA8.AM 4470 • • •: • • 07/29/94:....: OY9Q5.AM 4470 :0.04/01/98' • 1 B9A8.AM �••••. 4470 "' • ' 61/04/97 • • %• • 2B8A4.AM 4470 *. •: : • •(1'!/02/97 • • • • • 3B9Q1.AM .. 4470 •• •• • •••••• Ql/08/98 .' 3D4Q2.AM ...... 4470 . 05✓30/97 • • ••: - 797-03221-267 4470 : • 09%27/07 • • 797-03825-267 4470 797-10228-267 4470 ' W/23/15 UL LLC R1306 UL 790 08/21/18 PRI Construction Materials GAF-122-02-01 TAS 139 05/07/06 Technologies, LLC GAF-270-02-02 ASTM D226 11/15/10 GAF-276-02-01Rev ASTM D6083 12/16/10 GAF-276-02-02 ASTM D226 11/15/10 GAF-306-02-01 ASTM E96 07/07/11 GAF-314-02-01 ASTM D2178 08/23/11 GAF-315-02-01 ASTM D2178 08/23/ 11 GAF-369-02-01 ASTM C1289 10/22/12 GAF-417-02-01 ASTM C1289 05/28/13 GAF-464-02-01 ASTM C1289 10/22/12 GAF-464-02-01 ASTM C1289 02/06/14 GAF-499-02-01 ASTM D6083 03/12/14 GAF-500-02-01 ASTM D6083 03/12/14 GAF-549-02-01 TAS 114 08/08/14 GAF-549-02-02 TAS 114 08/08/14 GAF-559-02-01 TAS 117(B) 09/30/14 GAF-559-02-04 ASTM D 1876 10/01/14 GAF-559-02-05 ASTM D 1876 10/15/14 GAF-559-02-06 TAS 114(II) 10/02/14 GAF-559-02-07 ASTM D 903 10/02/14 GAF-559-02-08 ASTM D 903 10/02/14 NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 6 of 27 EVIDENCE SUBMITTED: (CONTINUED) Test Agency PRI Construction Materials Technologies, LLC IRT of S. Fl. Trinity I ERD Dynatech Engineering Corporation Atlantic & Caribbean Roof Consultants, LLC Test Identifier GAF-559-02-09 GAF-559-02-11 GAF-559-02-12 GAF-559-02-13 GAF-559-02-14 GAF-559-02-15 GAF-559-02-16 GAF-559-02-18 GAF-559-02-19 GAF-628-02-01 02-005 02-014 C8500SC.11.07 G30250.02.10-3-R2 G31360.03.10 G33470.01.11 G34140.04.11-2 G34140.04.11-4-R2 G34140.04.11-5-R3 G36780.07.11-R1 G40630.01.14-1 G40630.01.14-2A G40630.01.14-2A-1-Rl G43610.01.14 G6850.08.07-1 SC6870.08.14-R1 SC9700.08.15-R1 SC10680.05.16 SC13105.03.17-R1 #4482.02.95-1 11-053 Description ASTM D 903 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 ASTM C1289 TAS 114: TAS 114 ...... TAS 117.00.•. ASTM D39QV * * . ASTM D61 "' ASTM D6164' ..' ASTM D6163 • • • • ASTM D6441 ' ASTM D4827 4470-TAS 1140 ASTM D6163 ASTM D6164 ASTM D6164 ASTM D3909 ASTM D3909 ASTM D3909 ASTM D2178 ASTM D6163 ASTM D6164 TAS 114 TAS 114 Date 10/02/14 10/14/14 10/14/14 10/15/14 10/15/14 10/15/14 10/15/14 10/15/14 04/16/15 •9 31/16 ''e71;8/02 ••••�• '83%22/02 '• .. ...... 1 T/30/07 : *06703115 03%.31110 V I tnt/11 04/25/11 .Q§/P.4/15 06/04/15 o�hB/11 W706/14 01/07/14 04/10/14 01/22/14 08/13/07 09/04/14 8/31/2015 5/10/2016 3/23/2017 09/01 /95 08/12/11 MIAMFDADE COUNTY NOA No.: 18-0919.07 • Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 7 of 27 •....• APPROVED ASSEMBLIES Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(1): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Roof Deck Protection, (optional) VersaShield® Solo' Fire -Resistant Slip Sheet, DensDeck® Roof Board, Securock® Glass - Mat Roof Board or Securock® Gypsum Fiber Roof Board installed per manufactmer's installation instructions. '....' ....., Anchor sheet: GAFGLAS® #80 Ultima7 Base Sheet, GAFGLAS® Strataventl'Naiiable Veating$ase ....:. Sheet or Ruberoid® 20 Smooth mechanically fastened as described Wow. • Fastening GAFGLAS® Ply 4, GAFGLAS® Flex Ply"' 6, GAFGLAS® #75 BaseNlieet or ally of above.... Option #1: anchor sheets attached to deck with approved annular ring shank mailer and tia ja$$ at a • • : • • • fastener spacing of 9" o.c. at the lap staggered and in two rows 181,d.C. in thAeld. • •.. • • Not for use with DensDeck or Securock Fire Barrier """ • ...... (Maximum Design Pressure —45 psf. See General Limitation #�J • • • • • • Fastening GAFGLAS® Ply 4, GAFGLAS® F1exPly 6, GAFGLAS® #75 Bane Sheet or and ofabove ' Option #2: anchor sheets attached to deck with Drill-Tec' #12 Fastener, Drill-Tec' #14 Aastener and Drill-Tec' 3" Steel Plate, Drill-Tec"m AccuTrace Flat Plate or Drill-Tec' AccuTrac" Recessed Plate 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #9) Fastening GAFGLAS® F1exPly" 6, GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of Option #3: above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —52. S psf. See General Limitation #7) Fastening Any of the above anchor sheets attached to deck with approved 1'/4" annular ring shank nails Option #4: and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —60 psf. See General Limitation #7) Fastening GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill-Tec' Option #5: #12 Fastener, Drill-Tec' #14 Fastener and Drill-Tec' 3" Steel Plate, Drill-Tec' AccuTrac® Flat Plate or Drill-Tec' AccuTrac® Recessed Plate 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #9) MIAMFQADE COON Y NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 8 of 27 Fastening (Continued) Any of above anchor sheets attached to deck approved annular ring shank nails and 3" Option #6: inverted Drill-Tec' insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —60 psf. See General Limitation #7) Fastening GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill-Tec' Option #7: #12 Fastener or Drill-Tec' #14 Fastener and 3" Drill-Tec"' 3" Steel Plate, Drill-Tec' AccuTrac® Flat Plate or Drill-Tec' AccuTrac® Recessed Plate 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —4S psf. See General Limitation #9) One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners . * 711stener (Table 3) : •density/W • • • : • EnergyGuard' Polyiso Insulation, EnergyGuard'' Ultra Polyiso Insulation, EnergyGuar d #H Par�yiso, • .... • Insulation, EnergyGuard"' RA Polyiso Insulation, EnergyGuard'" RA Composite Polybp�jgsulation • • Minimum 1" thick N/A .... .. .N/A :.... EnergyGuard' Perlite Recover Board, DensDeck® Prime Roof Board • • • • • • • • • • • ...... . . ..... Minimum 1/�" thick N/A .. • .. • .../A ...... EnergyGuard Perlite Roof Insulation ...... . . . . ...... Minimum %" thick N/A :...1Q/A . Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot as hal • � • PP� g PP p t'��}>i the EVT range and at a rate of 20-40 lbs./100 W. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® Stratavene Perforated Venting Base Sheet laid dry or a layer of EnergyGuarC Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Base Sheet: (Optional) Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS® #80 Ultima7' Base Sheet, Ruberoid® Mop Smooth, Ruberoid® Mop Smooth 1.5, Ruberoid® Mop Plus Smooth or Ruberoid® 20 Smooth, Ruberoid® HW Smooth or Ruberoid® HW 25 Smooth directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. applied in accordance with manufacturer's instructions. (see General Limitation #4). OR GAFGLAS® Stratavent® Perforated Venting Base Sheet loose -laid dry (not for use with perlite top layer insulation or composite polyiso top layer insulation). Ply Sheet: One or more plies GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® F1exPly 6 or GAFGLAS®#80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS® EnergyCap' Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. MIAMM E COUN7Y Approval Date: 11/08/18 Page 9 of 27 0 Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat' Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat' MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options. . . .... ...... ...... . .. ...... .... . .. ..... ...... . . ..... .. .. . ...... . . . . ...... APPROVED NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 10 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(2): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or (optional) VersaShield® Solo' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smoom o'r• GAFGLAS® Stratavent® Venting Nailable Base Sheet is secui*%Jas Oescriln*ab low. Fastening Miami -Dade County Approved min. 12 ga. Annular ring shank na3?s and min. T 5/8 in." * Option #1: diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor s*heet side ?asps and �• • • • • .... .. in. o.c. in the field of the sheet in two staggered rows. • .... . .. ..... (Maximum Design Pressure.-,45psf. See General Limitadoj&#7A. ..:..' Fastening Miami -Dade County Approved min. 12 ga. Annular ring shanKAjjs�and min. 1-5/8 in.* Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anthot sheet side laps and in. o.c. in the field of the sheet in two staggered rows. : 0 6 "' (Maximum Design Pressure. —52.5 psf. See General Limitation #?) : 4,• • 0 • Fastening Drill-Te6 ' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec'T' Option #3: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure. —52.5 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #4: AccuTrae Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Lim itaden #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #5: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure. —75 psf. See General Limitation #7) One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard' Polyiso Insulation, EuergyGuard"' Tapered Polyiso Insulation, EnergyGuardT' Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation, EnergyGuard' RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 11 of 27 Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ftz EnergyGuard' Perlite Roof Insulation Minimum %" thick N/A N/A Structodek' High Density Fiberboard Roof Insulation Minimum '/:" thick N/A N/A Securock® Gypsum -Fiber Roof Board, DensDeck' Prime Roof Board Minimum'/a" thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbsJ100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet (Optional): GAFGLAS' #75 Base Sheet, Tri-Ply' #75 Base Sheet, Ruberoid' 20 Smooth adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer: s installation instructions. • Ply Sheet: When optional base sheet and/or cap sheet is present: Two or more plies of GAFGLAS' Ply 4, Tri-Ply' Ply 4, GAfdf X1* Flex : Ply 6 adhered... in a full mopping of hot asphalt applied at 20-40 lbs./sq. instatlpjger man:tf8cVer's • • • installation instructions. • • • • • • • • • • i • •' .. .. . •..... When optional base sheet and/or cap sheet is not present: ""' • • Three or more plies of GAFGLAS' Ply 4, Tri-Ply' Ply 4, GA*FGLA'S' Flex Ply6 adhered in a full mopping of hot asphalt applied at 20-40 lbs.,s& in-Vlled�er• • • • • • manufacturer's installation instructions. • • •••• Cap Sheet (Optional): GAFGLAS' Mineral Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS' EnergyCapT" Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbsJsq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 3001bs./sq. respectively in a flood coat of approved asphalt at 601bs./sq. 2. Topcoat' Membrane or Topcoat' Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat' MB Plus applied at 0.5 to 0.75 galJsq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 gal./sq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See fastening options above. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 12 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(3): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or (optional) VersaShield® Solo' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooll! bl. GAFGLAS® Stratavent® Venting Nailable Base Sheet is secured as describ*dbelow. Fastening Miami -Dade County Approved min. 12 ga. annular ring shanli'ii O lind min 72' /8 in. ""•' Option #1: diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide ancTor sheet side laps ands....: .... .. in. o.c. in the field of the sheet in two staggered rows. • .... . .. ..... (Maximum Design Pressure: —45 psf. See General Limitatio%#T,l. . ..;.. • Fastening Miami -Dade CountyAProved min. 12 ga. annular ring sh jk$and min. 1-5/8 in. •: Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide arthot sheet sitle laps and (� , •; in. o.c. in the field of the sheet in two staggered rows. 0 0 ""' (Maximum Design Pressure: —52.5 psf. See General Limitattien�#� • • Fastening .... Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #3: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure. —52.5 psf. See General Limitation #7) Fastening Drill-TecT' #14 Fasteners and Drill-Tec"' 3 in. Standard Steel Plates, Drill-Tec' Option #4: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure. —60 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #5: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —75 psf. See General Limitation #7) NOA No.: 18-0919.07 MIAMFW►DECOUNTY Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 13 of 27 One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ftz EnergyGuard' Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation, EnergyGuard' Ultra Polyiso Insulation, EnergyGuard"' RH Polyiso Insulation, EnergyGuard7 RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ftz EnergyGuard" Perlite Roof Insulation Minimum 3/4" thick N/A N/A Structodek® High Density Fiberboard Roof Insulation Minimum %" thick N/A .ANA . . .... ...... SecurocV Gypsum -Fiber Roof Board, DensDeck® Prime Roof Board • • • • Minimum %" thick N/A ...... N,/A' ....:. Note: All insulation shall be adhered in a full mopping of approved hot asphalt within $0brj6E*VT rggge jand at3e see: rate of 20-401bsJ100 fe. Please refer to Roofing Application Standard RAS 117 for i 1wJ"fon at&c%mtnt. ..... Base Sheet: Ruberoid 20 Smooth adhered in a full mopping of hot hay • • � fed at j@A* bs./s •::: • • ® PP� g aspha � q...... Cap Sheet: GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR GrAu*fR;p Sheet or GAFGLAS® EnergyCap"' Mineral Surfaced Cap Sheet adhergd in j full nVrppmg of hit • •, asphalt applied at 20 — 40 lbsJsq. installed per manufacturer's' WAa4ation,insVuctions;... •; . . . Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbsJsq. and 300 lbsJsq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See fastening options above. APPRGVED J NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 14 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(4): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: TOPCOAT FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or (optional) VersaShield® Solo"' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberpid®;0 Smoo* 0 0 " • GAFGLAS® Stratavene Venting Nailable Base Sheet is secufetl As described below. .' Fastening . . . ....... Miami -Dade County Approved min. 12 ga. annular ring shanl.&U; . . and mm. f*-.5/8 in. Option #1: diameter tin caps are spaced 8 in. o.c. in the min. 4 in. wide anqhg4sheet side laps and $ • • • ; in. o.c. in the field of the sheet in two staggered rows. **so** ; • .. • 0 0 (Maximum Design Pressure: —45 psf. See General Limitadorr f 7) ; ; � . � ; � • • • • • Fastening . ...... Miami -Dade County Approved min. 12 ga. annular ring sham.P.W.; and min. 1-5/8 in. . • Option #2: diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide an'choi sleet side lays and 6. •.:. in. o.c. in the field of the sheet in two staggered rows. • (Maximum Design Pressure: —525 psf. See General Limitaddit #7) ; • • • Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' Option #3: AccuTrac® Flat Plates or Drill-Tec'' 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: 52.5 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill -Tee' 3 in. Standard Steel Plates, Drill-Tec' Option #4: AccuTrae Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec", 3 in. Standard Steel Plates, Drill-Tec' Option #5: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —82.5 psf. See General Limitation #7) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 15 of 27 One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener Density/fe (Table 3) EnergyGuard7 Polyiso Insulation, EnergyGuardm Tapered Polyiso Insulation, EnergyGuard"' Ultra Polyiso Insulation, EnergyGuard' RH Polyiso Insulation, EnergyGuarC RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 2040 lbsJ100 it'. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: GAFGLAS® Stratavent® Perforated Venting Base Sheet is laid dry over the insulation. Ply Sheet: When optional cap sheet is present: Two or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. instaped per manali ; rer's • installation instructions. • ...... . .. ...... When optional cap sheet is not present: • • • • • • • Three or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAPCiL1 * Fl4t p11 b • adhered in a full mopping of hot asphalt applied at 20-40 lbs./s q! .... Mstalled�er• . manufacturer's installation instructions. • • • • • • . ...... Cap Sheet (Optional): GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Graj&e. ",ap Sheet dr •. GAFGLAS® EnergyCap' Mineral Surfaced Cap Sheet adhered in a full moppiab of hot • • • asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's igstaration jmt;petions; • • • • Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 3001bs./sq. respectively in a flood coat of approved asphalt at 601bs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 galJsq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See fastening options above. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 16 of 27 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: 19/32" thick or greater or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(5): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOut'" Fire Barrier Coating, VersaShieldc Fire -Resistant Slip Sheet or VersaShield' (optional) Sold" Fire -Resistant Slip Sheet. Anchor sheet: GAFGLAS' #75 Base Sheet or Tri-Ply® #75 Base Sheet is secured as described below with Dade County Approved min. 12 ga. galvanized ring shank nails and 32 v&,•1-5/8 in. diameter tin tabs. • • *see so**:* •• • •• • • Fastening: Nails and tabs are spaced 8 in. o.c. in the 4 in. wide side lap and.& in. o.c. +n *Goo:* staggered rows in the field of the sheet. • • • • • • • One or more layers of any of the following insulations. ' ....' : ' ..' ..... ...... . . ..... Base Insulation Layer Insulation Fasteners ...... ;' 4 tCner • • • • (Table 3) 0* 0 9 0 0 Density/ft2 .• EnergyGuard" Polyiso Insulation, EnergyGuard' Tapered Polyiso Insulation, Energ' Guasd"' RH Polyiso ....:. Insulation, EnergyGuard"' RH Tapered Polyiso Insulation : • Minimum 1" thick N/A • • • • •'PVo, :*see: •••• Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' Structodek' High Density Fiberboard Roof Insulation, Securock® Gypsum -Fiber Roof Board Minimum %" thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-401bsJ100 W. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Ply: Two or more plies of GAFGLAS' FlexPly"' 6 adhered with hot asphalt applied at 20-25 lbsJsq. Cap Ply: GAFGLAS' Mineral Surfaced Cap Sheet adhered with hot asphalt applied at 20-25 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbsJsq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat' Membrane or Topcoat' Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 galJsq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 gal./sq. Maximum Design Pressure: —52.5 psf. (See General Limitation #7) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 17 of 27 i 1 � Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type C: All layers of insulation are mechanically attached to roof deck. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOut"' Fire Barrier Coating, VersaShield' Fire -Resistant Slip Sheet or VersaShield' (optional) Solo"' Fire -Resistant Slip Sheet. One or more layers of any of the following insulations. . . .... ...... Base Insulation Layer (Optional) Insulation Fasteners : • . Pgtener • (Table 3r' ; .. . Ddnsity/W •' EnergyGuarC Polyiso Insulation, EnergyGuard' RA Polyiso Insulation, EnergyGua'rg"AN Polyiso Insulation • • Minimum 1" thick N/A • : : :' • ' N/A • .... . .. ..... Note: All layers shall be simultaneously fastened; see top layer below for fasteners and rft-tener; ty.Idswinhonpanels listed are minimum sizes and dimensions; if larger panels are used, the numbe : shall be Increased maintaining the same fastener density. Please refer to Roofing Application $taadjkrd RAS 17 for ... insulation attachment. GAF requires either a ply of GAFGLAS' Stratavent® Perforated Venting VkUlgheet . laid dry or a layer of EnergyGuard' Perlite Roof Insulation or wood fiber overlay board o4all • • :' polyisocyanurate applications. • • • • Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 SECUROCK' Gypsum -Fiber Roof Board Minimum'/." thick 2,8 1:1.78 ft2 Base Ply: Two or more plies of GAFGLASO F1exP1y 14 6 adhered with hot asphalt applied at 20-25 lbs./sq. installed per manufacturer's installation instructions. Cap Ply: GAFGLAS' Mineral Surfaced Cap Sheet, Tri-PI)r' BUR Granule Cap Sheet or GAFGLAS' EnergyCap'" Mineral Surfaced Cap Sheet adhered with hot asphalt applied at 20-25 lbs./sq. installed per manufacturer's installation instructions Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat' Membrane or Topcoat' Surface Seal SB applied at 1 to 1.5 galJsq. OR Topcoat' MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 galJsq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: —60 psE (See General Limitation #7) NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 18 of 27 ► .. Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type D: All insulation is loose laid with preliminary attachment to roof deck. Anchor sheet is subsequently mechanically fastened through insulation to the roof deck. All General and System Limitations shall apply. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard*°' Polyiso Insulation, EnergyGuard' Ultra Polyiso Insulation, EnergyGuard'' RA Polyiso Insulation .... Minimum 1.3" thick N/A • . • • • • I�/A • • • • • • .. . . Structodek® High Density Fiber Board . • • . • 000090 . Minimum 1" thick NIA ...:.. .N/A . ...... Note: Insulation shall have preliminary attachment, prior to the installation of the basi;A 04 at a 6iniaium ' ' 00 application rate of two fasteners per board for insulation boards havingno dimensio r th • 4 and' . . . four fasteners for any insulation board having no dimension greater than 8 & All layers oMsuhWdd; 8ptional.... thermal barrier (when present) and base sheet shall be simultaneously fastened See base skeet below for •' fasteners and density. Please refer to Roofing Application Standard RAS 117 for insulation attacbmm • • • • : • Fire Barrier: FireOut"' Fire Barrier Coating, VersaShiel& Fire Resistant RooPQrtkTrot4or. ,' • • • (optional) VersaShield® Solo' Fire -Resistant Slip Sheet, DensDeck® Roof Board, Secu=aW.13lass- Mat Roof Board or Securock' Gypsum Fiber Roof Board. Base Sheet: Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS® #80 Ultima7 Base Sheet, GAFGLAS® Stratavent* Nailable Venting Base Sheet or Ruberoid® 20 Smooth applied over the loose laid insulation with 2" side laps mechanically fastened as described below; Fastening Drill-Tec' #12 Fastener or Drill-Tec" #14 Fastener and Drill -Tea"' 3" Steel Plate, Drill - Option #1: Tec 3 in. Ribbed Galvalunie Plate (Flat), Drill-Tec' AccuTrac® Flat Plate or Drill-Tec' AccuTrac® Recessed Plate is installed through the base sheet and insulation in 3 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #9) Fastening Drill-Tec' #12 Fastener or Drill-Tec' #14 Fastener and Drill-Tec'" 3" Steel Plate, Drill - Option #2: Tec 3 in. Ribbed Galvalume Plate (Flat), Drill -Tea' AccuTrac® Flat Plate or Drill-Tec' AccuTrac® Recessed Plate is installed through the base sheet and insulation in 4 rows 8" o.c. One row is in the 2" side lap. The other 3 rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf. See General Limitation #9) Fastening GAFGLAS® #80 Ultima' Base Sheet, Ruberoid' 20 Smooth, Ruberoid® Mop Smooth Option #3: attached to deck with approved annular ring shank nails with a minimum embedment of 1" into the wood substrate and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. Not for use with DensDeck or Securock Fire Barrier (Maximum Design Pressure —60 psf. See General Limitation #7) NOA No.:18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 19 of 27 Fastening (Continued) Drill-Tec' #12 Fastener or Drill-Tec"' #14 Fastener and Drill-Tec"' 3" Steel Plate, Drill - Option #4: Tec 3 in. Ribbed Galvalume Plate (Flat), Drill-Tec"O AccuTrac® Flat Plate or Drill-Tec' AccuTrac® Recessed Plate in 4 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf. See General Limitation #9) Ply Sheet: One or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® F1exPly 6 or GAFGLAS® #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply BUR Granule Cap Sheet or GAFGLAS® EnergyCap' Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of . .... ...... approved asphalt at 60 lbs./sq. '..' .. .' 2. Topcoats Membrane or Topcoat® Surface Seal SB applied at 1 to * . gal./sq. """ OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a'priwA) follbAA By ..... Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. ...... . . ..... 3. .. .. . ...... Fiber Aluminum Roof Coating. ...... .' Maximum Design . . . . ...... Pressure: See Fastening Options NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 20 of 27 Membrane Type: BUR Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank decks secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(1): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOut' Fire Barrier Coating, VersaShield® Fire Resistant Roof Deck (optional) Protection, VersaShield® Solo' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Base sheet: GAFGLAS® #80 Ultima' Base Sheet, Stratavent® Nailable Venting Base Sheet, Ruberoid' 20 Smooth, Ruberoid® SBS Heat Weld"' Smooth or Ruberoid® SBS Heat -Weld' 25 base sheet mechanically fastened to deck as described below; Fastening GAFGLAS® Flex Ply 6, GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of Option #1: the above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 99 ote the yin field •••• •••••• (Maximum Design Pressure —52.5 psf. See General LimitadonT7) ' • • Fastening ...... . .. GAFGLAS® #80 Ultima7 Base Sheet, Ruberoid®20 Smooth opRuberoid® Mop Smooth...... Option #2: • • • • attached to deck with approved 1 %4" annular ring shank nails ary3 hutted 3; %eel plate at a • fastener spacing of 9" o.c. at the 4" lap and in two rows staggere$'with a fastensts .....pacink'cT' .. .... 9" o.c. in the center of the membrane. • • • • . • • 00 (Maximum Design Pressure —60 psf. See General Limitation #T� ... . .' . Ply Sheet: . One or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4 or GAFGLA�' #80 k ltnma Bas � • • • • Sheet adhered in a full mopping of approved asphalt applied witbijf tit EV't range and 4V • •, rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. 0 o: o o * Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS® EnergyCap"' Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 4001bs./sq. and 3001bsJsq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 galJsq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 184919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 21 of 27 Membrane Type: BUR Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank decks secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(2): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOut' Fire Barrier Coating, VersaShield® Fire Resistant Roof Deck (optional) Protection, VersaShield® Solo"' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #80 Ultima Base Sheet mechanically attached with Miami -Dade County Approved min. 1'/4 long, 12 ga., annular ring shank nails and 1-5/8" diameter tin caps spaced T' o.c. in the min 4" wide side laps and in 3 staggered rows in the field of the sheet. Ply Sheet: Two or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® F1exPly'" 6 adhered to the base sheet in full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. • • • • Cap Sheet: One ply of GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply(H) �Vi Vranuy� Cap Sheet or , • GAFGLAS® EnergyCapTM Mineral Surfaced Cap Sheet adherediaafall mappi*' of ....:. approved asphalt applied within the EVT range and at a rate of 20A}lbs./sq. installed pel manufacturer's installation instructions. • • • • • • • Surfacing: .... . .. ..... Optional on granular surfaced membranes; required for smooth vpemb%gqr,, jChosen: • • components must be applied according to manufacturer's apVUMon instructions. ' • • • ; • All coatings must be listed within a current NOA. . . . . ...... • 0 0 0 • • 1. Gravel or slag applied at 400 lbs./sq. and 3001bs./sq. respectiveV isaMood Coat of approved asphalt at 601bs./sq. .". ' 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 galJsq. Maximum Design Pressure: -82.5 psf. (See General Limitation #7) NOA No.: 18-0919.07 rtu4rtwao� cout�rrr Expiration Date: 11/04/23 JA Approval Date: 11/08/18 Page 22 of 27 Membrane Type: BUR Deck Type 1I: Wood, Non Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(4): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: TOPCOAT FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet (optional) VersaShield' Solo'' Fire -Resistant Slip Sheet, installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS' #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or GAFGLAS' Stratavent® Venting Nailable Base Sheet is secured as described below. Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. diameter Option #1: tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure. —45 psf. See General Limitation #7) Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-518 IdNiameter Option #2: tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side iapsand 6 in. o c in the • • • • : • .. field of the sheet in two staggered rows. • • •000*00 • (Maximum Design Pressure. —52.5 psf. See General Limitation #7) .. ; .. • Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates• IT.-Tec"' Aocu*Frac®� • Option #3: Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spy 16 in. off. injhe miq,„• in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheetifitA stagktied lows....... (Maximum Design Pressure. —52.5 psf. See General Limitation #71 • • • Fastening . . . ...... Drill-Tec"' #14 Fasteners and Drill-Tec"' 3 in. Standard Steel Plates:Dri11-Tec"' �\c'c'lfrrac® . Option #4: Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaod 12 in. o,c. in -the miri �� • in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure. —60 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec' 3 in. Standard Steel Plates, Drill-Tec' AccuTrac® Option #5: Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure. —97.5 psf. See General Limitation #7) Base Sheet: Ruberoid® 20 Smooth adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS EnergyCar Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. NOA No.: 18-0919.07 Expiration Date: 11/04/23 Approval Date: 11/08/18 Page 25 of 27 " .i Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoats Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat' Membrane applied at 0.5 to 0.75 galJsq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See Fastening Above. . . .... ...... ...... . .. ...... .... . .. ..... ...... . . ..... .. .. . ...... . . . . ...... NOA No.: 18-0919.07 MIAMaW1DECOUNTY Expiration Date: 11/04/23 JAPPROVEDI Approval Date: 11/08/18 Page 26 of 27 Miami Shores V11age Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE. BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores Fl 33138 Date: • • Y••• •••••• Re: Owner's Name: /,Pr5 r •••• •• •• Property Address: -4a A)C 4- •••••• •• "••" Roofing Permit Number: • • • Dear Building Official: ":' •: :...:. • •' • • • certify that I am not required to retrofit the root to WWII connections of my. ••: • . . :..... . . building because: • • • • • • ehe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please aMkt proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) �� 177dVRt Signature Print Name State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned Sworn to and subscribed before me this /-Z day of tC 6 as I X:!y Y Cristcba oftNOTARY PUBUC -+STATE OF FLORIDA Notary Public, Sate of Florida at Large ww COMnW FF92O 30 • tg Expires 1 V1312019 • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 SECTION 1524 HIGH VELOCITY HURRICANE ZONES —REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 2. P Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). �? 4• -Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; theiafs e, roofing nail penetration of the underside of the decking may not be acceptable:This provides ttKe.option of--**:* maintaining the appearance. ...... s• _Overflow scuppers (wall outlets): It is required that rainwater flows oV@o that Fe -roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof exten ' * * blo this. discharge if overflow scuppers (wall outlets are not provided. It may be neces Xj"IbY � � • P Y}►Ittistalt dlktfldW ...... scuppers in cordance with the requirements of Sections R4402, R4403 and R44Q9 Owner/Agent ture Date Contractor Signature DI `12 NC CiA Si r �IM ,,�r St^ovrS Property Address Permit Number Revised on 7/9/2009 LD;07/01/2015;