RC-18-2294Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
�-` tfU
Issue Date:10/19/2018
Permit NO.: RC•8-18 2294
Permit Type: Building (Residential) J
Work Classification: Shed
Permit Status: Approved
Expiration: 03/13/2019
Location Address Parcel Number Project
897 NE 91 TER, Miami Shores, FL 33138 1132060050300 <NONE>
Contacts
CARLOS BENITEZ Owner CARLOS BENITEZ Applicant
897 NE 91 TER, MIAMI SHORES, FL 33138 897 NE 91 TER, MIAMI SHORES, FL 33138
Other:3058109866 Other:3058109866
HOME OWNER Contractor
HOME OWNER
Description: NEW SHED 8X10 = 80 SOFT Valuation: $ 2,600.00 Inspection Requests:
305-762-4949
TotalSq Feet: 80.00
Fees
Amount
CCF
$1.80
DBPR Fee
$2.00
DCA Fee
$2.00
Education Surcharge
$0.60
P&Z Review Fee
$35.00
Permit Fee
$100.00
Scanning Fee
$9.00
Structural Review ($45)
$45.00
Technology Fee
$2.40
Total:
$197.80
Building Department Copy
Payments Date Paid
Amt Paid
Total Fees
$197.80
Credit Card 10/19/2018
$295.60
Credit Card 08/28/2018
$50.00
Amount Due:
$-147.80
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated.
Authorized Signature: Owner / Applicant / Contractor / Agent Date
October 19, 2018 Page 2 of 2
VOi
011(1 12018
BUILDING
PERMIT APPLICATION
Miami Shores Village
g
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
AUG 28 2 18
FBC 20 1-7 ��11
Master Permit No. rRus—z2-Iq
Sub Permit No.
❑ BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION [:]RENEWAL
❑ PLUMBING ❑ MECHANICAL ❑ PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 6-1Q 7 WE 1(5r7Sf124C
City: Miami Shores County: Miami Dade zip:
Folio/Parcel#: Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): liPeLps Ti:iw ( IlRa Phone#: 30s-- RAO 9&00
Address:
City: TgFTwtll`-C State: TL— Zip: 3-'�( 39
Tenant/Lessee Name:.
Email: C ben)
CONTRACTOR: Company Name: burfr r Phone#:
Address:
City: State:
Qualifier Name:
ne#:
State Certification or Registration #: Certificate of Competency #: _
DESIGNER: Architect/Engineer: Phone#:
p:
Address: City: State: Zip:
Value of Work for this Permit: $ Z—1 WO Square/Linear Footage of Work: ?3y
Type of Work: ❑ Addition (❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition
Description of Work:
Specify color of colorJthru tile:
Submittal Fee $ S (J� Permit Fee $ CCF $ CO/CC $
Scanning Fee $
Radon Fee $
Technology Fee $ Training/Education Fee $
Structural Reviews $
DBPR $
Notary $
Double Fee $
Bond $ 90
TOTAL FEE NOW DUE $ i Q '
(Revised02/24/2014)
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature Signatu
OWNER or AGENT CONTRACTOR
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
=� day of AQ �kE-t�_?-� 20 1 B , by
CGr ts� S M� • mks personallycknoDwn to
me or who has produced 44 l � 9�'� d^' as
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
day of , 20 , by
who is personally known to
me or who has produced as
identification and who did take an oath.
NOTARY PUBLIC:
", Sign:
Print: MAHARAIK.GONZALEZ Print:
MY COMMISSION
Seal: N ~ EXPIRES: November 2, 2020 Seal:
�o
F �; o?' Bonded Ttxu Notary Public Underwr tens
***********************************************************************************************************
APPROVED BY �SIU� Plans Examiner I0 Zoning
y Structural Review Clerk
(Revised02/24/2014)
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNER BUILDER DISCLOSURE STATEMENT
� �
NAME: C ACwS I TE!-- DATE: 1 G�
ADDRESS: 4BOP7 KC— "1 M�/T��11�5{° d � ;;198
Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have
read and understood the following disclosure statement, which entitles me to work as my own contractor; I further understand that I as the owner
must appear in person to complete all applications.
State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption
allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the
construction yourself. You may build or improve a one -family or two-family residence. You may also build or improve a commercial building at a
cost of $25,000.00 or less (The new form states 75,000). The building must be for your own use and occupancy. It may not be built for sale or
lease. If you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built
for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make
sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on
your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and
with -holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all
applicable laws, ordinances, buildings codes and zoning regulations.
Please read and initial each paragraph.
1. 1 understand that state law requires construction to be done by a licensed contractor and have applied for an owner -builder permit under an
exemption from the law. The exemption specifies that I, as the owner of the property listed, may act as my own contractor with certain
restrictions even though I do not have a license. Initial_ n `k
2. 1 understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and
is not hiring a licensed contractor to assume responsibility.
Initial_
3. 1 understand that, as an owner builder, I am the responsible party of record on a permit. I understand that I may protect myself from potential
financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that the
contractor is required by law to be licensed in Florida and to list his or license numbers on permits and contracts.
Initial
4. 1 understand that I may build or improve a one family or two-family residence ona farm outbuilding. 1 may also build or improve a commercial
building if the costs do not exceed $75,000. The building or residence must be for my use or occupancy. It may not be built or substantially
improved for sale or lease. If a building or residence that 1 have built or substantially improved myself is sold or leased within 1 year after the
construction is complete, the law will presume that 1 built or substantially improved it for sale or lease, which violates the exemption.
Initial_
5. 1 understand that, as the owner -builder, 1 must provide direct, onsite supervision of the construction.
Initial_
6. 1 understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence. It
is my responsibility to ensure that the persons whom I employ have the license required by law and by county or municipal ordinance.
Initial_
7. 1 understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner -builder permit that erroneously
implies that the property owner is providing his or her own labor and materials. I, as an owner -builder, may be held liable and subjected to
serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's
insurance may not provide coverage for those injuries. I am willfully acting as an owner -builder and am aware of the limits of my insurance
coverage for injuries to workers on my property.
Initial_ �b
8. 1 understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the
work being done. Any person working on my building who is not licensed must work under my direct supervision and must be employed by
me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the
Federal Insurance Contributions Act (FICA) and must provide workers compensation for the employee. I understand that my failure to follow
these may subject to serious financial risk.
Initial_ KP
9. 1 agree that, as the party legally and financially responsible for this proposed Construction activity, I will abide by all applicable laws and
requirement that govern owner -builders as well as employers. f also understand that the
Construction must comply with all applicable laws, ordinances, building codes, and zoning regulations.
Initial
10. 1 understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service, the United States
Small Business Administration, and the Florida Department of Revenues. I also understand that I may contact the Florida Construction Industry
Licensing Board at 850.487.1395 or h_ttp://www.myfloridalicense.com/dbpr/pro/cilb/index.htmi
InitialAL
11. 1 am aware of, and consent to; an owner -builder building permit applied for in my name and understands that I am the party
legally and financially responsible for the proposed construction activity at the following address:
f • low
/ ,I
Initial
12. 1 agree to notify Miami Shores Village immediately of any additions, deletions, or changes to any of the information that I have provided on
this disclosure. R.�-,0
Initial
Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the
Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial
loss that you sustain as a result of contractor may be in civil court. It is also important for you to understand that, if an unlicensed contractor or
employee of an individual or firm is injured while working on your property, you may be held liable for damages. If you obtain an owner -builder
permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is properly licensed and the status of
the contractor's workers compensation coverage.
Before a building permit can be issued, this disclosure statement must be completed and signed by the property owner and returned to the local
permitting agency responsible for issuing the permit. A copy of the property owner's driver license, the notarized signature of the property
owner, or other type of verification acceptable to the local permitting agency is required when the permit is issued.
Was acknowledged before me this 13 day of 20
_,
M �n �o was personally known tome or who has
0
Ox4
aa
ap
yZ
'
GzZNN
gN�ZC.ByCOYIa
�YcJ9
o
Produced they ense or as identification.
_ -E LU z
t
¢ p a q
U
X
} tiJ m
OWNER NOTARY
8/28/2018 Property Search Application - M i am i- Dade County
�r ,
OFFICE TPROPERTY APPRAISER
Summary Report
Property Information
Folio:
11-3206-005-0300
Property Address:
897 NE 91 TER
Miami Shores, FL 33138-3217
Owner
CARLOS M BENITEZ
SAMAR E BENITEZ
Mailing Address
897 NE 91 TER
MIAMI SHORES, FL 33138 USA
PA Primary Zone
0900 SG FAMILY - 1901-2100 SQ
Primary Land Use
0101 RESIDENTIAL -SINGLE
FAMILY: 1 UNIT
Beds / Baths / Half
3/3/0
Floors
1
Living Units
1
Actual Area
2,339 Sq.Ft
Living Area
1,663 Sq.Ft
Adjusted Area
2,070 Sq.Ft
Lot Size
10,500 Sq.Ft
Year Built
1951
Assessment Information
Year
2018
2017
2016
Land Value
$283,331
$283,331
$231,322
Building Value
$108,054
$108,054
$108,054
XF Value
$15,000
$15,000
$15,000
Market Value
$406,385
$406,385
$354,376
Assessed Value
$367,132
$333,757
$303,416
Benefits Information
Benefit
Type
2018
2017
2016
Non -Homestead Cap
Assessment Reduction
$39,253
$72,628
$50,960
Note: Not all benefits are applicable to all Taxable Values (i.e. County, School
Board, City, Regional).
Short Legal Description
GOLDEN GATE PARK ADDN PB 6-130
LOT 26 & E1/2 LOT 25 BILK 2
LOT SIZE 75.000 X 140
COC 23792-0102 08 2005 1
Generated On : 8/28/2018
Taxable Value Information
2018
2017
2016
County
Exemption Value
$0
$0
$0
Taxable Value
1 $367,132
$333,757
$303,416
School Board
Exemption Value
$0
$0
$0
Taxable Value
1 $406,385
$406,385
$354,376
City
Exemption Value
$0
$0
$0
Taxable Value
$367,132
$333,757
$303,416
Regional
Exemption Value
$0
$0
$0
Taxable Value
$367,132
$333,757
$303,416
Sales Information
Previous
OR Book-
Price
Qualification Description
Sale
Page
05/04/2018
$675,000
30985-2334
Qual by exam of deed
12/29/2015
$100
29920-3938
Corrective, tax or QCD; min
consideration
12/26/2014
$340,100
29449-2156
Financial inst or "In Lieu of Forclosure"
stated
08/01/2005
$650,000
23792 0102
Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property
Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
Version:
9 .N
BUILDING
PERMIT APPLICATION
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
RzCF-d4F-9
MAR 13 WS
0_,c
Tel: (30S) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
❑BUILDING ❑ ELECTRIC ❑ ROOFING
FBC 201 i
Master Permit No. PC-8- —/8 2 2 0t
❑ REVISION
Sub Permit No._
EXTENSION
[:]RENEWAL
❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: u `-� Wc 7T-9—
City: Miami Shores County: Miami Dade Zip:
Folio/Parcel#: Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): l Agto� Phone#: *5`}�
Address: 7
City: NIA -MI State: Zip: 1 ��
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR: Company Name: Phone#:
Address:
City: State: Zip:
Qualifier Name: Phone#:
State Certification or Registration #: Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#: -
Address: City: State
Value of Work for this Permit: $ Square/Linear Footage of Work:
Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace
Description of Work:
Specify color of color thru tile:
Submittal Fee $ Permit Fee $
Scanning Fee $ Radon Fee $
Technology Fee $ Training/Education Fee $
Structural Reviews $
M
❑ Demolition
CCF $ CO/CC $
DBPR $ Notary $
Double Fee $
Bond $
TOTAL FEE NOW DUE $
(Revised02/24/2014)
Bonding Company's Name (if applicable)
f.
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
Zip
City State Zi
.01' .
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature ''L-'� �� Sign
OWNER or AGENT CONTRACTOR
The foregoing instrument was acknowledged before me this
day of QJQV 20 �� by
PlnI KhTs personally �k-no�wln to
WI I Ye me or who has produced ( ias
identification a6d1who did take an oath.
NOTARY PU
Print:
The foregoing instrument was acknowledged before me this
day of
me or who has produced
20 , by
, who is personally known to
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
N
MY COMMISSION # GG 044602
Seal: EXPIRES: November 2, 2020 Seal:
o ; 4P' Bonded Thru Notary Public Underwriters
as
******************************* ***************************************************************************
/ L
APPROVED BY / Plans Examiner Zoning
Structural Review Clerk
(Revised02/24/2014)
C'�vJN� i2. O�
PA �Cr ��
c2 7/ s
MIA-Ml 5 az—eS
w
o V �
r D
D e—
AS\f pi trI
9[ c) q86�-
' Ordered By: - Proudly Serving
HG JJ 1
the Florida Real
C "t ME LAND
'"' "�'ome's 1 '••'.. t< Estate Communi
a� Miami Shoes ' ,�
TC $ C [•V •1 f C 5 1 n f ') O ' "f ;h :z r�,� v _ for Over 20 Years
Ga;9Ie NE01u1' e�°.usm�eaoaw WWW.MFI_ANI)Sf'RVICGS.COM
t, AUG 8 018
7
B.C.
T 2 a a LOT 1 o F.I.P. 1 Z
B CK 2 0 75.00' (P z BL 2 g (No. l�j
" 25.0
E 25' OF S f' N .� -.i.
LOT 25 I Ig d ...•
BLOCK 2 a o •.. • . .
s' wooD L T 26
FENCE OC NC BL CK 2 IL�"— I •••••• • ' ••••
• .
I oh it •...... .•
E25 OF a ••••i •• ••••
LOT25 0.70' C.B.S 0000010 . . ..:.
WALL • ; • • '
BLOCK 21
c
M 3.901 •° , • •.••
• •, •� •
1 a_Z0• 33.83' 15.71' zo • '0 � • • .. •
3.90' 4' 25.45' •�
4.0' 11`— cn . • •
I ONE STORY + , m Z
17.70' ui RESIDENCE LL1
ui t w
25.40 C C 4' 25.45'
EMAINDER OF 9 0, + - Q � j{ Z
LOT 25 7.0 �+ . o c o `coNc ° 3: t 1 j Q
BLOCK 2 O CONC I N N PORCH D0! CONICRIVE o.i Q -
O �o STAIRS 19.0' r~ . ". LIJ 4--'
Q 39.98' - �t 0)
�8.90' 19.30' 15.71 .
I CD O C:)C;CONC I 1 f h QQ
P� ' o AC . 30.�0' N O a
Its
1
= M 4.0' 1° a
oZ p � C I ONE STORY 1�
(
a RESIDENCE " i I� e A C in # 897 1 iv".ialri 6 ��.r I rJ
Q° IM 15.10' DATE
CD3 �p.s2' s.o 71 pFROVE 13Y..
c
.oa o C 1A
p ST S _ONING D PT
n 6 ' o lJ 1
_ {9.18 3 o, o BLDG nEP
ERAL
C n a 3• M j 1 cc;P'JPlr.lr` N
m
Q M CONIC io STAI E AN Lr.I�ti I �IJL=' ND ftEUUlAT10N;
F.LP. 1/2" 25.
(NO. ID.) 75.00' (P) F.I.P.�2»
c 15' PARKWAY o /
ui 4' Q
SQ' . RIGHT-OF=.WA.Y . (BY PLAT)
20'ii A5PPAL : AAV"M . `
_ _�._ 1
(SUNSET AVENUE BY PLAT _
N.E. 91 St TERRACE _ _V
Accepted By:
Property Address:
Notes: NO NOTES
897 N.E. 91 Terrace
Miami Shores, FLORIDA 33138
SURVEYOR'S CERTIFICATION:IHERBy - THATTHIBBOUNDARYSURVEI'ISATRUEANO
CORRECT A IONOFA ®UNDERMYDIRECTION. THIS COMPUEb
WITH THE MINIMUM TECHNIC FORTH BY THE STATE OFFLORIDA BOARDOr
M.E. Land Surveying,InC.
10665 SW 190th Street
PROFESSIONAL LAND SUR C f7- THROUGHW7.0S2FLORDA
PURS t*
ADMNISTRATNECODE A gr� A ATUEs.
Suite 3110
SIGNED o ° FOR THE FIRM
Miami, FL 33157 ME LAND_
EFRAIN LOP FICA A
STATE OF FL P.S.M. No. 6792
r
Phone: (305) 740-3319
Fax: (305) 669-3190
NOT VAUDWITHOUT AND AUTH IC SIGNATURE AND AUTHENTICATED
LB#:7989
ELECTRONIC SEALANDARTHISMAPIS VAUDWITHOUTTHESIGNATUREANDTHEORIGINAL
Survey #:B-40678 Client File #: 18-0243 Page 1 of 2 Not valid without all pages
Surveyor's Legend
PROPERTY LINE
STRUCTURE
CND FOUND IRON PIPE D.R. BEARING REFERENCE TEL. TELEPHONE FACILITIES
/
CONC. BLOCK WALL
PIN AS NOTED ON PLAT G CENTRAL ANGLE OR DELTA V.P. UTILITY POLE
—X—X— CHAIN -LINK FENCE OR WIRE FENCE
LB/ UCENSE # - BUSINESS R RADIUS OR RADIAL E.U.B. ELECTRIC UTILITY BOX
WOOD FENCE
LS# LICENSE 0 - SURVEYOR RAD. RADIAL TIE SEP. SEPTIC TANK
—^o—o-^ IRON FENCE
CALC CALCULATED POINT N.R. NON RADIAL D.F. DRAINFIELD
— EASEMENT
SET SET PIN TYP. TYPICAL A/C AIR CONDITIONER
- — CENiER LINE
♦ CONTROL POINT I.R. IRON ROD S/W SIDEWALK
WOOD DECK
CONCRETE MONUMENT I.P. IRON PIPE DWY DRIVEWAY
BENCHMARK N&O NAIL k DISK SCR. SCREEN ~
CONCRETE
ELEV ELEVATION PK NAIL PARKER-KALON NAIL GAR GARAGE
i
L.G.L.LGLGJ ASPHALT
P.T. POINT OF TANGENCY D.H. ORILL HOLE ENCL. ENCLOSURE
P.C. POINT OF CURVATURE WELL N.T.S. NOT TO SCALE
HumBRICK / TILE
••••
P.R.M. PERMANENT REFERENCE MONUMENT ® FIRE HYDRANT F.F. FINNISHED FLOOR
• •
%,
P.C.C. POINT 0 COMPOUND CURVATURE ® N.H. MANHOLE T.O.B. TOP OF BANK
• • •
P.R.C. POINT 0 RCVERSE CURVATURE O.H.L. OVERHEAD LINES E.O.W. EDGE OF WATER
• • •/�-• • 4k:PRORIMATE EDPE O WATER
P.O.B. POINT- OF BEGINNING TX TRANSFORMER E,O,p EDGE OF PAVEMENT
., ,..__y. •
•--�. - • • • • • •
COVERED AREA
P.O.C. POINT OF COMMENCEMENT CATV CABLE TV RISER 0.v.C. CONCRETE VALLEY GUTTER
• • • - - -�
P.C.P. PERMANENT CONTROL POINT W.M. WATER METER B.S.L. BUILDING SETBACK LINE
• • • 1-� • • TTdr. • • • • • •
M FIELD MEASURED p/E POOL EQUIPMENT S.I.L. SURVEY TIE LANE
POLE
• • • • PO•w€R POLE • • • • • •
0 PLATTED MEASUREMENT CONC. CONCRETE SLAB q, CENTER LINE
• • • F • • � • • • • • •
0 DEED ESMT EASEMENT R/W RIGHT-OF-WAY
• C.U.E. 4OUNTY UTILITY ZASFVJ%•
C CALCULATED D.E. DRAINAGE EASEMENT P.U.E. PUBLIC UTILITY EASEMENT
• • •Ij./E.E. • INGRESS / EGRF•LS CASEN04T
L.M.E. LAKE OR LANDSCAPE MAINT. ESMT. LB,E. LANDSCAPE BUFFER EASEMENT C.M.E. CANAL MAINTENANCE EASEMENT
tLE. • • L71U*4 EASEMENT • •
R.O.E. ROOF OVERHANG EASEMENT LA.E. LIMITED ACCESS EASEMENT A.E, ANCHOR EASEMENT
Property Addrie§s:
General Notes:
1.) The Legal Description used to perform this survey was supplied by others.
897 N.E. 91 Terrace
This survey does not determine or is not to imply ownership
Miami Shores, FLORIDA 33138
2•) This survey only shows above ground improvements.
Underground utilities, footings, or encroachments are not located on this survey map
3.) If there is a septic tank, well, or drain field on this survey,
Flood Information:
the location of such items was shown to us by others and the information was not verified.
4.) Examination of the abstract of title will have to be made to determine recorded instruments, if any, effect this prop
Community Number: 120652
erty.The lands shown herein were not abstracted for easement or other recorded encumbrances not shown on the pl
Panel Number: 12086CO306L
at
Suffix: L
5.) Wall ties are done to the face of the wall.
6.) Fence ownership is not determined.
Date of Firm Index: 09/11/2009
7.) Bearings referenced to line noted B.R
Flood Zone: X
8.) Dimensions shown are platted and measured unless otherwise shown.
Base Flood Elevation:
9.) No identification found on property comers unless noted.
10.) Not valid unless sealed with the signing surveyors embossed seal.
Date of Field Work: 04/20/2018
11.) Boundary survey means a drawing and/or graphic representation of the survey work performed in the field; coul
Date of Completion: 04/24/2018
d be drawn at a shown scale and/or not to scale
12.) Elevations if shown are based upon NGVD 1929 unless otherwise noted
13.) This is a BOUNDARY SURVEY unless otherwise noted.
14.) This survey is exclusive for the use of the parties to whom it is certified. The certifications do not extend to any u
nnamed parties.
15.) This survey shall not be used for construction/permitting purposes without written consent from the land
surveyor who has signed and sealed this survey.
Legal Description:
Lot 26 and the East 1/2 of Lot 25, Block 2, Golden Gate Park Addition, according to the plat thereof as recorded in
Plat Book 6, Page 130, Public Records of Miami -Dade County, Florida.
Printing Instructions:
Certified To: r`
While viewing the survey in any PDF Reader, select the File
Carlos M. Benitez and Samar E. Benitez ;
Drop -down and select "Print". Select a color printer, if available;
Clear Title Services, Inc.
J
or at least one with 8.5" x 14" (legal) paper.
Old Republic National Title Insurance Policy Issued Through
Select ALL for Print Range, and the # of copies you would like to
Attorneys' Title Fund Services, LLC.
print out.
Caliber Home Loans, Inc.
Under the "Page Scaling" please make
sure you have selected
its successors and/or assigns as their interest may appear.
"None".
"Auto
Please copy below for policy preparation purposes only:
Do not check the -rotate and Centel"
box.
Check the "Choose Paper size by PDF"
checkbox, then click OK
This policy does not insure against loss or damage by reason of the following
exceptions: Any rights, easements, interests, or claims which may exist by reason
to print.
of, or reflected by, the following facts shown on the survey prepared by_
EFRAIN LOPEZ dated 0412412018 bearing ,lob # B-40678 :
a. NO NOTES
M.E. Land Surveying, Inc.
10665 SW 190th Street, Suite 3110 Miami, FL 33157
ME LAND
ME LAND
--
Phone: (305) 740-3319 V, -
Fax: (305) 669-3190 F
LB#: 7989
Survey #:B40678 Client File #: 18-0243 Page 2 of 2 Not valid without all pages
Via... .
Busi
��` f i1 s I \'
o essioNl
Regu',
Wion
Ken Lawson, Secretary
Alex Martens
Superior Sheds, Inc.
2323 S. Volusia Ave
Orange City, FL 32763
September 23, 2016
RE: Manufacturer Certification, ID MFT-113; Expiration Date: September 22, 2019
IgLA Manufactured t3LO&V Program
1940 Norlh Mon.oe Sireet
Suave 90A
Tallahassee, Florida 32399.07'12
MOW W 487,1824, Fax 850,414 8436
RickScott, Govemor
Dear Alex Martens • • •
• • • • • •
It is my pleasure to inform you that Superior Sheds, Inc., located at 2323 S. Volusia Ave, Orange: e
City, FL 32763, has been approved under the Manufactured Buildings Program, as provided for • • •
under Chapter 553, Part I, Florida Statutes, to manufacture Storage Sheds, Manufactured • •"
Buildings for installation in Florida. •, • • • •
Construction or modification on a manufactured building cannot begin until the Third Party ' • • • • `
Agency has approved the plans in accordance with the current Florida Building Code. Your Third • • • •
Party Agency is a contractor for the Department and has statutory authority and responsibilities•
that must be met to maintain approved status. You may expect and demand quality plans • • •
review and inspections. so
Each Code change will make your plans obsolete until they have been reviewed, approved and
indicated (on the cover page of the plans] for compliance with the Code by your Third Party
Agency for plans review. Please ensure that your plans are in compliance and are properly
posted on our website. All site -related installation issues are subject to the local authority
having jurisdiction.
The Department's contractor will make unannounced monitoring visits at least once each year.
You must grant complete access to your manufacturing facility and records to remain in
compliance with the rules and regulations of this program.
Your certification is approved for three years from this date. You will receive a renewal notice by
Email generated by the BCIS (www.floridabuildi or) for online renewal. If you have questions
you may contact Robert Lorenzo at 850-717-1835 or our FAX at 850-414-8436.
Please visit our website at www.floridabuilding oro to see valuable information on the Florida
Manufactured Buildings Program. A copy of this letter must accompany applications for local
building permits.
cc: Professional Service Industries
Sincerely,
Robert Lorenzo
Manufactured Buildings Program
fee*
Y •
feet
•e•e••
• • •
•
r
••••••
t• •
• •
J • •
••
•••••
•• •
•••e•
to
'
•
•
• •
•
••••••
•e••••
•c••••
e• •
• •
•• •
APPROVED
DATE 1h�
PSI APPROVAL 2018-01-18
r D4 ALUMINUM ROOF SHEATHING
0 -0 MAX.
I
ih
0
1x4
RUNNERS
0
I
0
w
a
END WA
TRUSS
2"x4" TRUSS
0 24" O.C.
MAX.
Side Wall Header Schedule (180C)
End Wall Header Schedule 180C
S¢e{d}
Max Span
NJ(b}
Fasteners w/o strap
each end
Building Width
Fasteners w1 Strap
(each end)
Size Up to 14' Wide
`
1 2"x4'
6-0
0
4 3" x 0.131' nails
Max. Span
NJ{b}
Sc4" < G
1)
M
0 {d }
..' x 1 nails
1-4'x4' G-0'
0
3 - 3° x 0.131" nails
a. abUlated values are for No. grade Spruce in it lumber
b. NJ Number ofjack studs required to support each end
c Laid flat
d No bck studs, but 2x6 studs laid flat
4'x4" w2'h4" ; R-0'
1
6 - 3" x 0.131" nails
a. Tabulated values are for No. 2 grade Spruce -Pine -Fir lumber.
b. NJ - Number ofjack studs required to support each end.
c. Window header for window openings that have more than 509% combined stud wall above
•t�s
and below, otherwise use door header schedule.
d. Be header details �r alternate layouts, i.e. 2-2'x4" or 4'x4' P.T.
1. SEE FASTENER SCHEDULE FOR HARDWARE REQUIREMENTS.
2. SEE HEADER SCHEDULE FOR ON
e. The header can be attached to the top plate and thus have the combined strength
3. WINDOW HEADERS WIVE COMBINED 50X OR MORE WAIL FRAMING ABOVE
COMBINED SOX R MORE
AND Sao*. OTHERWISE REFER TO DOOR HEADERS.
equivalent and use the maximum span stated.
( a� LA `.
CODE INFO ION
CODE VERSION FBC 2017 In, Ear'°"' E-7,
2014 NEC
MANUFACTURER SU--
WN.L STUDS 1T^ BUILDING TYPE 9"WW=RED BUILDING
RESIDENTIAL LAWN STORAGE
II
CONSTRUCTION TYPE V-B
2".4"
ExTERgR HEADER FIRE PROTECTION NONE
Ii SHEATHING
SINGLE
II i II FIRE SUPPRESSION SYSTEM NONE
Lj11 (z) 2•.4' WITH 1/2' PLYWOOD
OR OSB FILLER OR (1)4"x4' 2'z4' OCCUPANCY STORAGE
12'.12' OR 1614' BETWEEN 4'v4• ALLOWABLE NUMBER OF STORIES 1
J. WALL STUDS. VENT IS SECURED
To SHEATHING AS PER 12" MAX. BASIC WIND SPEED vM-,eomp,
MANUFACTURERS INSTRUCTIONS
HYDROVENT DETAIL SIDE WALL WINDOWS END WALLS WINDOWS & EXPOSURE c
�OPTIONALL & DOORS DOOR 6' WIDE OR LESS 4"x4" W/2"x4" ENCLOSURE Wiwi
INTERNAL PRESSURE•COEFF101ENT - .18•
IMPORTANCE FACTOR • • 1.15 0000,
cV>tL'r'ttak„ ROOF DEAD LOAD • • • • • • • = • •
G. F.1. + NOTES -OPTIONAL ELECTRIC [ idr ROOF LIVE LOAD • • • • • 3OPSF OR 30011, Polo t" •
OUTLET �11iaaJ FLOOR DEAD LOAD ,OPSF •
ALL WIRING SHALL BE 14 GAGE 3-WIRE MC CABLE • • • •
N ii -ENCASE IN ALL METAL BOXES. a . FLOOR LIVE LOAD •
SOURCE f • • !JD. APSF - 125PW OPT. •
DESIGN PRESSURES
L I
'� `
R' RATING OF W , F OOR, ROOF
N/A* • • • • • •
ROOF +27.8/-94.7 ROOF
FRAMING PLAN
WIRING DIAGRAM
" `"
(,. �... s, rr.'-.rr.==. ';>
MODULES PER BUILDING •
* • •.• •
•
WALLS/DOORS/WINDOWS +32.5/-29.2
(OPTIONAL)
Plans Review: Victor G Martin, PE
HURRICANE PROTECTION •
tb •
FL PE k62379, U PE IT4201]
USAGE
• •
-
LSUCCC#U02436, TN PE 9120939
HURRICANE SHE' USAGE•
N00 •
MREK OR ALPINE 2'x6'
END WALL
-DOOR & WINDOW LOCATIONS VARY
SQUARE FOOTAGE •
719,9o.FT. OR LESS •
• •
OR EQUAL
MMNN
Cil1Y7" 1".4' COuAN
MITEK OR ALPINE 25 -
s HEADS DETAIL
REV
DPSCRIPTONo o
Sal
OR EO
/
• •
•
/
// D4 ALUMINUM WALL
VARIE
// // // // // SHEATHING OPTIONS
2' MAX. VARI / / /
SEE HEADER
//
/ /
3 MAX.
2a4
24' O.C. 1A PC
DETAIL
1.4 RUNNER /
ON INSIDE
// // //
/
LLJ
Drawn By:
2.4 eLocaNc
END WALLS
/ /// /
/ /
Z
MTB
J
Date:
12/12/17
/
O
,-
Scale:
END WAIL
N A
2-STUDS O
2z4 SOLE �`TE
(n LLI
.del
2.4 501E PLATE
2.4 SOLE PUTS"[T
24' O.C. MAX.
FLOOR FRAMING
(n
SS-B-180CR1
J LLl
I
1. FOUNDATION PLANS ARE NOT PART OF THIS PLAN SET AND ARE
FLOOR FRAMING
J
GOVERNED BY LOCAL JURISDICTION.
THIS
ALL STUDS SECURED TO SOLE PLATE
w -J
2. BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION
CODE PER SECTION 1015,22.
AND FLOOR FRAMING WITH 0.039•
0_
3. REFER TO TIE -DOWN DETAILS FOR PROPER INSTALLATION
LJ
(tmm)a12" STEM W/8-10a NALS STANDARD WALL DETAIL
NOTE- WALL FRAMING MEMBERS ARE CONTINUOUS FROM
<
Q
REQUIREMENTS TO MEET CODE
L'J
L'J
L`J
OR EQUAL
WITH DOOR &WINDOW OPTIONS
FOUNDATION SILL TO ROOF AND SECURED TO ENSURE A
CONTINUOUS LOAD PATH. WHERE WALL MEMBERS ME
O
4. ALL STUDS, RAFTERS, TRUSSES, ETC. ARE 2.4 i2 SPF, EXCEPT
As NOTED.
MISS 6'-0" TO 13'-8'
MISS 6'-D' TD 13'-8'
FLooft SFIEATIIING.
-. 3/4' PLYWOOD
NOT CONTINUOUS, SHEET METAL CLAMPS, TIES, OR CUPS
U
5. STRUCTURES OVER 4o0 so. FT. WILL HAVE AN 80" MINIMUM
ELEVATION CROSS-SECTION
END ELEVATION
4'a0 P.T. ATTACHED WIM
- 3/4' P.T. PLYWOOD
- 3/4' T&G
SRALL RE FORMED OF cALVANRW STEEL OF NOT LESS
THAN 0.040' NOMINAL THICKNESS.
Lyf
pOpR.
6. CUTTERS TO BE INSTALLED ON -SITE BY OTHERS THRU LOCAL
TYPICAL ARCH FRAME
WITH DOOR
H24 OR EOUNALENT. SEE
TABLE 2 FOR QUANTITY AND
- 3/4" P.T. T&G
'^•-0"
t1.1
CODES
7. ALL WINDOWS AND DOORS TO MEET THE MINIMUM SPECIFICATIONS
SPACING.
MAX
\!)
AS PER FLORIDA BUILDING CODE.
8. FLAT METAL STRMSU CAN BE BENT MOUND STRUCTURAL MEMBERS
of WALL STUDS, TRUSSES, CHORDS, ETC. TO HELP SECURE THESE
-.
____
____
____
____
____
___
L
KI ft
R P I
MtMtltlp; PINWIUEU IHAI IHt AUUEU tlENO GOES ROT INTERFERE
WITH ANY EXISTING BRACES BENDS IN THE STRAP.
2.
244 0 MAX. (2) 2"x4" WD FLAT
(TCN
�� �� �F�
z
__ _ _
___
SHED WIDTH
8
ifi 0'
x,
0'-10'
X2
461'0
x3
-
_
`�`` 1111 i 11 /, /',/
�`` • ••• •'� �C L I �SE ••••••`%
'M4uS NNE iA04 .N RIOT COno6 Q u) 4'M'LL \ : • // '
1 51006 ONL. 13'_r 11M 511.E nML (4) gl6 W
LU
2-BLOCKING ON p , ^
Wall I V
2.4 BLOCKING END I j
� I Q '
2".6' LAD MT 'a j • ` -T,
b j 2.6 P.T. 20 O.C. TYP. •� STATE
• `L 1
g I OPTIONAL 120PSF • 16' O.C. �•'; 4V \
TYP. WITH 3/4' T&G PLYBOARD 0 (J •'. OF .• `�
2.4 501E PLATE 4'x4' P.T. ATTACHED WITH '� ••• _ r ')- 0 RR24 i r • \ �`
BOOR FRAMING I TAB OR FOR RUM. SEE •' .........•••• .• •��
TABLE 2 FOR Ol14NTTn' AND �� S ••• ,� `�
MAX 7SPACING. / '\
g. �0 IN A L
J
"J LxJ L1 j
Q
LxJ L11 II
otthew T. Baldwin P.E.
ARISES 6'-0• TO 13'-8'
MIES 6'-0' To ,3•-6' - t--- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- --- z Florido License #64608
END ELEVATION END ELEVATION
FLOOR JOIST, SEE SCHEDULE FOR SIZE
WITHOUT DOOR WITH GARAGE DOOR
(ONLY ON ENDWAl) FLOOR FRAMING PLAN t m Sheet:
SSB-1 OF 1
SETUP AND INSTALLATION OF SINGLE WIDE SHED
SETUP AND INSTALLATION OF DOUBLE WIDE SHED
1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR
MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC.
2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE
BUILDING IS BLOCKED ON THE HIGH SPOT AND LEVELED. THE OTHER END OF THE
BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING
IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED.
3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT
SPACING (SEE TABLE 3).
4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED
THRU THE 2%4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL
1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE.
5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO
FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS.
6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND
BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE
CONCRETE 1-1/2" OFF OF RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM
PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2"
WEDGE ANCHOR.
7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE
2%4" BOTTOM PLATE.
TABLE 1
ANCHORING TO CONCRETE
SHED WIDTH
UPLIFT (PLF)
ANCHOR SPACING
20'-0"
400
3'-6"
13'-8"
280
3'-6"
11'-8"
240
S-6"
10'-0"
200
S-g'
8'-0"
160
S-6„
6'-0"
120
3,-6„
TABLE 2
SKID RUNNER SPACING*
SHED WIDTH
X1
X2
X3
13'-8"
1'-104„
1'-10�"
1'-104"
11'-8"
2'-8"
6'-4"
-
10'-0"
V-7"
6'-10"
-
8'-0"
0'-9"
6'-6"
-
6'-0'
0'-10"
51"
-
*VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"x4"
SKIDS ONLY. 13'-8" WIDE SHEDS HAVE (4) SETS OF SKIDS.
30" AUGER ANCHOR
(4,900LB)
INSTALLED PER MANUFACTURER'S
INSTRUCTIONS. EYELET AT
MAXIMUM OF 6" ABOVE GRADE.
1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS
PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP.
2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE
BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3).
3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE
FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1)4%44"
BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE
LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS
PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE.
4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B).
5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS
REMOVED.
6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO
FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS.
TABLE 3A
PAD TYPES
TYPE
PAD DIMENSIONS
MAX. LOAD*
MATERIAL
I
2"x8"x16"
1778LBS
CONCRETE BLOCK QUALITY
CEMENT AND SAND MIX
II
4"x8"x16"
3500LBS
CONCRETE BLOCK QUALITY
CEMENT AND SAND MIX
III
16%16"
3950LBS
ABS PLASTIC PADS
IV
8%8"x16"
1900LBS
CONCRETE BLOCK QUALITY
CEMENT AND SAND MIX
* BASED ON 2000PSF SOIL BEARING CAPACITY (2000PSF IS TYPICAL)
.NOTES
1. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED
ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING.
2. ABS PADS REQUIRED ON I V-8" AND 13'-8" WIDE SHEDS ONLY.
TABLE 3
SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS
SHED DESCRIPTION
PAD
MAXIMUM LOAD AND PAD TYPE
SHED WIDTH
TYPE
LW*(PLF)
END PAD
MAX. SPACING
END PAD
SIDE RUNNER
PAD TYPE
INTERIOR
PAD
SIDE RUNNER
PAD TYPE
13'-8"
SW/DW
4.15/332
0" TO 6"
6'-0"
1936LB
I, II, III, OR IV
1879LB
I, II, III, OR IV
11'-8"
SW/DW
6.00/480
0" TO 6"
6'-0'
2558LB
I, II, III, OR IV
2558LB
I, II, III, OR IV
10'-0"
SW/DW
5.00/400
0" TO 6"
6'-0"
2400LB
I, II, III, OR IV
2400LB
I, II, III, OR IV
SW
4.00/320
0" TO 6"
6'-0'
2029LB
I, II, III, OR IV
2133LB
I, II, III, OR IV
5'-0"
SW
3.00/240
0" TO 6"
6'-0'
1658LB
I, II, III, OR IV
1866LB
1 I, II, III, OR IV
* LOAD WIDTH OF UPLIFT ON RUNNER
NOTES
1. PAD SPACING IS END TO CENTER OF PAD.
2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER.
3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING.
GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS
1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE
AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE
HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS.
2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER).
LOCATE ANCHORS PER TABLE 4A OR 4B.
3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE
(FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH
THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED
PORTIONS OF SHEDS ON LEVELING BLOCKS.
TABLE 4A
30" AUGER ANCHOR SPACING - SINGLE WIDE
SHED WIDTH
LW*
UPLIFT (PLF)
END ANCHOR**
MAX. INTERIOR SPACING***
13'-8"
7.00
243
0'-0" TO S-T
10'-0"
11'-8"
6.00
208
0'-0" TO 3,-0"
10'-0"
10'-O"
5.00
174
0'-0" TO 3'-0"
10'-0"
8'-0"
4.00
138
0'-0" TO 3'-0"
10'-0"
C-0"
3.00
104
0'-0" TO 3'-0"
10,-0"
TABLE B
30" AUGER ANCHOR SPACING - DOUBLE WIDE
SHED WIDTH
LW*
UPLIFT (PLF)
END ANCHOR**
MAX. INTERIOR SPACING***
20'-0"
10.00
400
0'-0" TO 3'-0"
5'-0"
* LOAD WIDTH OF UPLIFT ON RUNNER
'• LOCATION FROM END WALL OF AUGER ANCHOR
*•' MAXIMUM SPACING BETWEEN ANCHORS
NOTES
1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7.
2. ALL MEASUREMENTS ARE CENTER -TO -CENTER.
3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER.
ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-O"
BETWEEN ANCHORS..
4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN
EXISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE
TO THE SIDE AS POSSIBLE.
2"x2" GALVANIZED WASHER
2"x2" GALVANIZED WASHER
WITH 1/2" NUT
1/2" THREADED ROD
WITH 1/2" NUT
OPTIONAL FOR "HIGH SET"
NOTCH COUNTERSINK BOLT
1/2" THREADED ROD
EYES BOLTED TOGETHER WITH 1/2"x2"
"x
THRU 24" BOTTOM PLATE
OPTIONAL FOR "HIGH SET"
5-e
BOLT & NUT WITH (1)2"x2" GALVANIZED
1/2" COUPLER
2"x4" BOTTOM PLATE NAILED
1/2' COUPLERA
/
WASHERS (2.000LB SHEAR CAPACITY)
•_•
TO 2"x6" P.T. BASE
I r
1/2"x12" FORGED EYEBOLT
�i
" 4" MIN.
1/2"x5" (400 LB.) CONCRETE
WEDGE ANCHOR INTO SLAB
THRU 2"x4" P.T. BOTTOM PLATE
r 4" MIN.
GRADE
EYES BOLTED TOGETHER WITH 1/2"x2"
%
(SEE TABLE 1 FOR SPACING)
Ld------- ------ J__
TYPE I, II, III, OR IV PAD WITH
BOLT & NUT WITH GALVANIZED BLOCKING AS REQUIRED (SEE TABLE 3).
AR CAPACITY)
WASHERS (2.000LB LB SHEAR
1/2"x3" (400 LB.)
CONCRETE WEDGE ANCHOR
SIMPSON A-24 CONCRETE SLAB BY OTHERS THROUGH
CLIP OR EQUAL LOCAL CODES AND JURISDICTION
CONCRETE SLAB BY OTHERS THROUGH
LOCAL CODES AND JURISDICTION
30" EARTH AUGER ANCHOR
(SEE TABLE 1 FOR SPACING)
(SEE TABLE 4 FOR SPACING)
SHED WITH SKID
SHED
WITH SKIDANCHORED
SHED
'NOFLOOR'ION
TO PAD OR BLOCKING
TO CONCRETE
CO
ANCHOTH RED
CONCRETE
TIE-DOWN
DETAILS
' CODE VERSION I FBC 2017 6th Edition, /SCE-7 II
I MANUFACTURER SUPERIOR SHEDS
BUILDING TYPE
RESIDENTIAL LAWN STORAGE
CONSTRUCTION TYPE
V-B
FIRE PROTECTION
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
STORAGE
ALLOWABLE NUMBER OF STORIES
1
BASIC WIND SPEED
Vr-200wh
EXPOSURE
D
INTERNAL PRESSURI; COEF 181ENT
- 01a
IMPORTANCE FACTOR • • •
•1.15 0.0090
ROOF DEAD LOAD • • • • • • •
130SF• •
ROOF LIVE LOAD • • • • • •
2OPSF OR 3001bs• • • • • •
FLOOR DEAD LOAD • • • •
SPSF • •
~•
FLOOR LIVE LOAD **so • •
• 5PSF - 17%& OPT.
i
"R" RATING OF W/AL`5• 6LW2, ROOF
N • • • • •
MODULES PER BIJLQIITG • •
•1 • a • • •
HURRICANE PRO7�CTION USAGE
NO • • • • •
HURRICANE SHELTER Ull
ONO • •
SQUARE FOOTAGE •
Less THAN 720-SQ.F7. •
• • • REVISIONS
REV ftSCR1PTO019 • 17AiE+ 8Y
1 2017 FBC • • • • 111/12/171 ITS
2 GROUND ANCHOR 6" AF.G MAX., ANCHOR EXTENSION 5/26/1a Wire
U) - MTB
0 Date:
w 4/26/16
Scale:
(n N/A
Modell:
LI J ALL
C) GENERAL NOTES
1. FOUNDATION PLANS ARE NOT PART OF THIS
PLAN SET AND ARE GOVERNED BY LOCAL
JURISDICTION.
w 2. THIS BUILDING IS EXEMPT FROM THE FBC
ENERGY CONSERVATION CODE PER SECTION
-1
1015,22,
m 3. REFER TO TIE -DOWN DETAILS FOR PROPER
:D INSTALLATION REQUIREMENTS TO MEET CODE.
0
0
LiJ
J
0
LL
0 l
0 "'I
D
CD
o_
6/1 /18
Q
J
Q
Matthew T. Baldwin P.E.
Florida License #64608
w
� Z
Sheet: AD-1 OF 1