WS-19-170Permit NO.: WS-01-19-170 Miami Shores Village Permit Type: Wince/Shutters 10050 NE 2 Ave Miami Shores FL 33138 ft w rf(Classification: Window/Door Replacement 305-795-2204 Permit Status: Approved Issue Date:01/24/2019 Expiration: 07/23/2019 Location Address 70 NE 99 ST, Miami Shores, FL 33138 Contacts Parcel Number 1132060131050 JAY YAGODA Owner JAY YAGODA Applicant 70 NE 99 ST, MIAMI SHORES, FL 33138 70 NE 99 ST, MIAMI SHORES, FL 33138 'Other:3056577859 Other:3056577859 D. TORR GENERAL CONTRACTORS, INC Contractor SERGIO TORRES 218 NW 92 ST, MIAMI SHORES, FL 33150 Business: 3053019913 info@dtorrgc.com Mobile: 3053019913 Home: 3053019913 Other: 3053019913 Inspection Description: 5 NEW WINDOWS AND 1 EXTERIOR DOOR Valuation: $ 4,500.00 e nests: Ins 05-ection R9 TotalSq Feet: 216.00 11 Fees Amount Application Fee - Other $50.00 CCF $3.00 DBPR Fee $2.40 DCA Fee $2.00 Education Surcharge $1.00 Scanning Fee $12.00 Technology Fee $4.00 Windows/Shutters Fee $110.00 Total: $184.40 Building Department Copy Payments Date Paid Amt Paid Total Fees $184.40 Credit Card 01/24/2019 $184.40 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information i accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above med contractor to do the work stated. T1' -c- I i , i Authorized Signature: Owner / Applicant / Contractor / Agent January 24, 2019 Page 2 of 2 Miami Shores Village v Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION BUILDING ❑ ELECTRIC ❑ ROOFING r ? t - EY w 4, G 19 I BY: AJIA I l� C FBC 20 1 �k- Master Permit No. u ,, ifD - �z4 y Sub Permit No.V 4S" (I (__� �J ❑ REVISION ❑ EXTENSION ❑ RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: qct�— `� Folio/Parcel#: Is the Building Historically Designated: Yes NO ✓ Occupancy Type: Load: Construction Type: Flood Zone: _X_ BFE: FFE: 1 OWNER: Name (Fee Simple Titleholder): 1P X!6--r, 4z)4 Phone#: Address: rio f'�'1" 5r City: �A[ AV L S_ State: -(V zip: 33� 3g Tenant/Lessee Name: l Phone#: I Email: 10�0Aa \�O` OM,'lL • (,-NM CONTRACTOR: Company Name: . 102(l Ca)62AL CDAJ�_Aj4CYV2S Phone#: 3015"301, Address: 2 ILiI.(i RZ 5' City: M State: L Zip: 35/1&r_j Qualifier Name: 5"610 C2 -29U 65 Phone#: 30S 30� ?q13 State Certification or Registration``M C G G (SZ I u��Certificate of Competency #: cc�� �j DESIGNER: Architect/Engineer: ► 4t-A E �1- Phone#: 3 OQ - DDm — ( U I Add Value of Work for this Permit: Type of Work: ❑ Addition State: Zip: Square/Linear Footage of Work: ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: t5- Ilf:_:� l kKs1 1n15 %'_) d �z 12d aa2 Specify color of color thru tile: Submittal Fee $ Permit Fee $ Scanning Fee $ Technology Fee $ Structural Reviews $ Radon Fee $ Training/Education Fee $ CCF $ CO/CC $ DBPR $ Notary $ Double Fee $ Bond $ (Revised02/24/2014) TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address Zip City State Zip I Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature —' �f' �WNIE�RAGENT The foregoing instrument was acknowledged before me this day of :CAS 20 \ c by 'who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: ,, Ismael A. Pabon SAISN *- Commission # GG082163 Sign:JIU nt �� Bonded thru Aaron Notary Print: ��aTi ► �`�� Seal: net-- Signa 7?e�� CONTRACTOR The foregoing instrument was acknowledged before me this `ZL-"day of J an�c.r`I 20 \ q by S-f r G c. 1 r rCS who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Ismael A. Pabon Ali"�r= Commission # GN9163 _= Expires: March 13, 2021 Sign: � Print: V Seal: APPROVED BY Z 1 Plans Examiner Zoning , I Structural Review Clerk (Revised02/24/2014) Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Inspection requirements for: Windows, Doors, Skylights or Fixed Glass (cladding) Permits Upon issuance of permits for the scope of work involving the removal, changing and/or replacement of any type of windows, doors, sidelites, skylights or fixed glass (cladding) the permit holder or qualifier bearing his signature on the permit application shall abide by the requirements of this department and comply with the following statement: Upon obtaining window and/or door permits for the installation of same, it is the responsibility of the permit holder to request window/door framing in -progress inspection, prior to concealment of any horizontal or vertical clip mullion, bucks, shims, etc. Inspector will also verify anchor type, edge distance, embedment and spacing. The purpose for this inspection, is for the verification of conformance with. Product Approval (NOA). AcIdgement: Quay ier/Owner Signature Date _ter Print Name MIAMI-DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Eco Window Systems, LLC 8502 NW 80 Street Medley, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami .Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. 'DESCRIPTION:Series "Eco-Guard 200" Aluminum Horizontal Rolling_WindoyK.— L APPROVAL DOCUMENT: Drawing No. W09-12, titled "Eco-Guard Series-200 Alum. Horiz. Rolling Wdw. (I,.M.I.)" sheets I through 7 of 7, dated 02/24/09, with revision F dated 10/19/17, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. (MISSILE IMPACT RATING; Large and Small Missile Impact Resistant; I ABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 15-0728.05 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Sifang Zhao, P.E. y' 'Z NOA No. 17-1102.23i O��oS�rn�B (kxpiration Date: May 27, 2019 a Approval Date: January 11, 2018 Page 1- Eco Window Systems, LLC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA#09-0312.08) 2. Drawing No W09-12, titled "Eco-Guard Series-200 Alum. Horiz. Rolling Wdw. (L.M.I.)", sheets 1 through 7 of 7, dated 02/24/09, with revision F dated 10/19/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 4) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 along with marked -up drawings and installation diagram of an aluminum horizontal sliding window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL —7635, dated 12/09/14, signed and sealed by Marlin D. Brinson, P.E. (Submitted tinder NOA#14-0317.01) 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of a XOX aluminum horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-08-2226A, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under NOA # 0 9-0312.08) 3. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a XOX aluminum horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-08-222613, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under NOA #09-0312.08) 4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 along with marked -up drawings and installation diagram of a XOX aluminum horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-08-2227, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted tinder NOA#09-0312.08) S; �Gn q zti�.o Sifang Zhao, P.E. Product Control Examiner NOA No. 17-1102.23 Expiration Date: May 27, 2019 Approval Date: January 11, 2018 E-1 Eco Window Systems, LLC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 5. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of a XOX aluminum horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-08-2228A, dated 0l/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under NOA#09-0312.08) 6. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a XOX aluminum horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-08-2228B, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted underNOA#09-03I2.08) 7. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a XOX aluminum horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-08-2229, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under NOA 4 09-0312.08) 8. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a XOX aluminum horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-08-2230A, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under NOA409-0312.08) 9. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a XOX aluminum horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-08-2230B, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under NOA#09-0312.08) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 5ei Edition (2014), dated 07/08/15, complying with FBC 6« Edition (2017), dated 10/12/17 prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies with ASTM E1300-09 Sifang Zhao, P.E. Product Control Examiner NOA No. 17-1102.23 Expiration Date: May 27, 2019 Approval Date: January 11, 2018 E-2 Eco Window Systems, LLC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Interlayers" dated 01/19/17, expiring on 07/08/19. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on 07/04/18. F. STATEMENTS 1. Statement letter of conformance, complying with FBC St' Edition (2014), with FBC 6th Edition (2017), and of no financial interest, dated October 12, 2017, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad; P.E. G. OTHER 1. Notice of Acceptance No. 15-0728.05, issued to Eco Window Systems, LLC for their Series "Eco-Guard 200" Aluminum Horizontal Rolling Window - L.M.I.", approved on 09/03/15 and expiring on 05/27/19. Sifang Zhao, P.E. Product Control Examiner NOA No. 17-1102.23 Expiration Date: May 27, 2019 Approval Date: January 11, 2018 E-3 rCOUNTY MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DMSION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv ECO Windows Systems, LLC 9114 N. W. 106th Street, Medley, FL 33178 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION ,,Series_600 Aluminum Qutswing Doors-L.M.I� APPROVAL DOCUMENT: Drawing No. W12-08 Rev E, titled "Series 600 Alum Outswing Entrance Door (L.M.I.)", sheets 1 through 9 of 9 (inclusive 7.1), prepared by AL-Farooq Corporation, dated 02/13/12 and last revised on MAR 15, 2018, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING;, Large and -Small Missde.Impact Resistant } Limitation: 1. See Single or Double Door Design Pressure (DP) ratings in sheet 2. See Single or Double Door DP ratings with sidelites (w/wo Reinforcement) and Standalone Single sidelite rating in sheet 3. The max door leaf width shall not to exceed 37". See locking options 1 & 2 in sheet 7_1. 2. Laminated glass types G1 and G2 are limited to Kurarary's .090" Trofosil PVB and glass type G3 is limited to Insulated laminated glass w/ Eastman Chemical's .090" Saflex interlayer. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and following statement: "Miami -Dade County Product Control Approved", noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #17-1218.15 and consists of this page 1 and evidence pages E-1 & E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda, P.E. _y,NOA No. 18-0319.13 ie,ru•oaDe courinr t]L iration Date: March 20 2019 ` Approval Date: May 10,2018�) I K��`1� `- Page 1 ECO Windows Systems, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitted under previous approvals A. DRAWINGS 1. Manufacturer's die drawings and sections (see below) 2. Drawing No. W12-08 Rev C, titled "Series 600 Alum Outswing Entrance Door (L.M.I.)", sheets 1 through 9 of 9 (inclusive 7.1), prepared by AL-Farooq Corporation, dated 02/13 /12 and last revised on SEP 04, 2015, signed and sealed by Javad Ahmad, P.E. B. TESTS (submitted under file #12-0402.03) 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of an aluminum Outswing French door, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-12-3357, HETI-12-3358, HETI-12-4003, HETI-12-4003 and HETI-12-4027dated 03/16- 26/12, all signed and sealed by Rafael E. Droz-Seda, P. E. Note: The above referenced test reports have been revised by an addendum letter dated June 29, 2012, issued by Hurricane Engineering & Testing, Inc., signed and sealed by Rafael E. Droz-Seda, P. E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-2014(5th Edition), prepared by Al Farooq Corporation, dated June 02, 2015, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies w/ ASTME-1300-02, -04 & -09. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 11-0624.01 issued to Kuraray America, Inc. (Former E.I. DuPont DeNemours & Co., Inc. for the `Butacite ® PVB interlayer", expiring on 12/11/16. 2. Notice of Acceptance No. 12-1231.10 issued to Eastman Chemical Company (MA) (former Solutia, Inc.) for the "Saflex: Saflex Clear & Color glass interlayer", expiring on 05/21/16. 3. XL Edge seal System 201 SS spacer by Cardinal IG. F. STATEMENTS 1. Statement letter of conformance to FBC 2014 (51h Edition) and letter of no financial interest, prepared by Al Farooq Corporation, dated 06/02/15, signed and sealed by Javad Ahmad, P.E. 2. Addendum letter dated June 29, 2012, issued by Hurricane Engineering & Testing, Inc., signed and sealed by Rafael E. Droz-Seda, P. E. 3. Lab compliance as part of the above referenced test report. G. OTHER 1. This NOA revises NOA #15-0603.13, expiring 03/20/19. 2. Test proposal, dated 10/14/11 and 02-21-12 approved by PERA. Is aq I. Chanda, P.E. Product Control Examiner NOA No. 18-0319.13 Expiration Date: March 20, 2019 Approval Date: May 10, 2018 E-1 .ECO Windows Systems, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. New Evidence submitted. A. DRAWINGS 1. Drawing No. W12-08 Rev E, titled "Series 600 Alum Outswing Entrance Door (L.M.I.)", sheets 1 through 9 of 9 (inclusive 7.1), prepared by AL-Farooq Corporation, dated 02/13/12 and last revised on MAR 15, 2018, signed and sealed by Java Ahmad, P. E. B. TESTS 1. None. C. CALCULATIONS 1. Anchor verification calculations complying with FBC2017 (6th Edition), prepared by Al Farooq Corporation, dated OCT 31, 2017 and last revised on MAR 13, 2018, signed and sealed by Javad Ahmad, P.E.(submitted under file #17-1102.18) D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. (Former E.I. DuPont DE Nemours & Co., Inc. for the "Trofosil ® (Clear and Ultra clear) PVB Glass interlayers", expiring on 07/08/19. 2. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear & Color Glass Interlayer", expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance to FBC 51h Edition (2014) and FBC 6th Edition (2017) and of no financial interest, prepared by Al Farooq Corporation, dated 10/04/17, signed and sealed by Javad Ahmad, P.E. G. OTHER 1. This NOA revises NOA # 17-1218.15, expiring 03/02/2019. IsIhaq I. Chanda, P.E. Product Control Examiner NOA No. 18-0319.13 Expiration Date: March 20, 2019 Approval Date: May 10, 2018 E-2 r MM I DADE MIAIVII-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miami-dade.gov/economy Eco Window Systems, LLC 8502 NW 80 Street Medley, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. IDESCRIP.TION:_Series_"Eco-Guard 300"_Aluminum Fixed-Window.—.L.M.I APPROVAL DOCUMENT: Drawing No. W09-20, titled "Eco-Guard Series-300 Alum Fixed Wdw. (L.M.I.)", sheets 1 through 5 of 5, dated 03/23/09, with revision E dated 10/19/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant) LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 15-0715.10 and consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation -was reviewed by Sifang Zhao, P.E. NOA Ni 17-1102.20 MIAMFDADE COUNTY (Expiration Date: June 17, 2019) Approval Date: January 11, 2018'1 —Page I°J Eco Window Systems, LLC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA#09-0413.08) 2. Drawing No W09-20, titled "Eco-Guard Series-300 Alum. Fixed Wdw. (L.M.I.)", sheets 1 through 5 of 5, dated 03/23/09, with revision E dated 10/19/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 along with installation diagram of a 97 1/4" wide x 96 1/8" high Eco-Guard series 300 aluminum double fixed window, prepared by Hurricane Engineering & Testing Inc., Test Report No. HETI-08-2192A, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under NOA#09-0413.08) 2. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with installation diagram of a 97 I/4" wide x 96 1/8" high Eco-Guard series 300 aluminum double fixed window, prepared by Hurricane Engineering & Testing Inc., Test Report No. HETI-08-2192B, dated 0l/15/09, signed and sealed by Candido F. Font, P.E. (Submitted underNOA#09-0413.08) 3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 20294 3) Water Resistance Test, per FBC, TAS 202-94 along with installation diagram of a 48 1/4" wide x 96 3/8" high Eco-Guard series 300 aluminum circular arch top fixed window, prepared by Hurricane Engineering & Testing Inc., Test Report No. HETI-08-2193A, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under NOA#09-0413.08) 4. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with installation diagram of a 48 1/4" wide x 96 3/8" high Eco-Guards 300 aluminum circular arch top fixed window, prepared by Hurricane Engineering & Testing Inc., Test Report No. HETI-08-2193B, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under NOA#09-0413.08) 5. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with installation diagram of a 47 5/8" wide x 96" high Eco-Guard series 300 aluminum triangular top fixed window, prepared by Hurricane Engineering & Testing Inc., Test Report No. HETI-08-2194, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under NOA#09-0413.08) :5; fG,n 0, �,V Sifang Zhao, P.E. Product Control Examiner NOA No. 17-1102.20 Expiration Date: June 17, 2019 Approval Date: January 11, 2018 E-1 Eco Window Systems, LLC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 6. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 along with installation diagram of a 50 5/8" wide x 63 V4" high Eco-Guard series 300 aluminum fixed window, prepared by Hurricane Engineering & Testing Inc., Test Report No. HETI-08-2195A, dated 01/15/09, signed and sealed by Candido F. Font, P.E. (Submitted under NOA#09-0413.08) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 6th Edition (2017), dated 10/13/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Interlayers" dated 01/19/17, expiring on 07/08/19. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc, for their "SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on 07/04/ 18. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 5th Edition (2014), with FBC 611 Edition (2017), and of no financial interest, dated October 13, 2017, issued by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P.E. G. OTHER 1. Notice of Acceptance No. 15-0715.10, issued to Eco Window Systems, LLC for their Series "Eco-Guard 300" Aluminum Fixed Window — L.M.I., approved on 09/03/15 and expiring on 06/17/19, Sifang Zhao, P.E. Product Control Examiner NOA No. 17-1102.20 Expiration Date: June 17, 2019 Approval Date: January 11, 2018 E-2 f PART PERMIT RECETV]EI3 A 2,4 2019p` BY: GENERAL NOTE: • ALL ESCAPE WINDOWS SHALL PROVIDE A CLEAR OPENING OF NOT LESS THEN 5.7 SQUARE FEET. THE WIDTH SHALL NOT BE LESS THAN 20" AND THE HEIGHT SHALL NOT BE LESS THAN 24". THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" ABOVE FINISHED FLOOR. • WINDOW FRAMES/MULLIONS ANCHORAGE F PART TO MAIN STRUCTURE SHALL BE IN STRICT PERMIT ACCORDANCE WITH THE UNITS NOTICE OF ACCEPTANCE - REFER TO PRODUCT CONTROLS. • ONLY THE OPENINGS THAT ARE IDENTIFIED WITH THEIR PRODUCT CONTROL N.O.A. DESIGN PRESSURES AND SIZE ARE PART OF THIS PERMIT. ALL OTHER OPENINGS ARE NOT PART OF THIS PERMIT. ALL OTHER OPENINGS ARE NOT PART OF THIS PERMIT. AT t' kAY NEW MASTER SUITE PLANS _les Vida 3e I !APPHOV-0 BY DATE 70`4iNG DEP"f I RLDG DEPT .ItJ[ CT TO COMPLIANCE WITH ALL FEDERAL 1 A' [ A'..) CO)I 1N TY RU[. FS AND REGULATIONS } W S 8502 NW 80th STREET MEDLEY, FL, 33166 TEL: 305-863-2223 FAX: 305-863-2291 Cn O co .• In ... . OC LV 7- 00 re • • 0 0. .X. • W Z. . p� Z N. R61-181D.M—a Data PERMIT $heat N.ae, FLOOR PLAN Dn by J. REY st" Dale 01/15/2019 sWb 3/8' = 1' •• WINDOWS , DOORS MANUF. *DESIGN WIND TESTED WINDOW N.O.A. OPENING DESCRIPTION GLASS TINT FRAME COLOR PANEL STYLE WIDTH HEIGHT /MODEL PRESSURE(P.S.F.) PRESSURE(P.S.F.) 1 ALUMINUM FRENCH DOOR �M' CLEAR WHITE X 36" 80" ECO WINDOWS +38.4 +70 18-0319.13 IMPACT RESISTANT„ LowE SERIES 600 -53.7 -75 A ALUMINUM FIXED WINDOW �M' CLEAR WHITE O 24„ 76" ECO WINDOWS +40.1 +75 17-1102.20 IMPACT RESISTANT . LowE SERIES 300 -43.5 -80 A ALUMINUM FIXED WINDOW �M' CLEAR WHITE O 24" 76" ECO WINDOWS +40.1 +75 17-1102.20 IMPACT RESISTANT" LowE SERIES 300 -43.5 -80 B HORIZONTAL ROLLING " �M' CLEAR WHITE XO 48" 24„ ECO WINDOWS +40.1 +70 17-1102.23 WINDOW IMPACT RESISTANT LowE SERIES 200 -53.7 -80 B HORIZONTAL ROLLING �M' CLEAR WHITE XO 48" 24„ ECO WINDOWS +40.1 +70 17-1102.23 WINDOW IMPACT RESISTANT" LowE SERIES 200 -53.7 -80 C ALUMINUM FIXED WINDOW �M' CLEAR WHITE O 20" 20" ECO WINDOWS +40.1 +75 17-1102.20 IMPACT RESISTANT" LowE SERIES 300 -53.7 -80 NOTE * DESIGN WIND PRESSURES (P.S.F.) WERE TAKEN FROM A MASTER PERMIT PLAN. # RC-8-18-2047 UNITY WINDOWS 8502 NW 80th STREET MEDLEY, FL, 33166 TEL: 305-863-2223 FAX: 305-863-2291 VJ w O co M O • • w•OM L,-- : •): rn O •• cy):z:. Z• • ®Q Z F. No. Revlebelles„e Dote PERMIT Sheet Name DOORS & WINDOWS SCHEDULE Dt by Shed J. REY 3 Dds 01/15/2019 Sege N/A ae 3 1/2" MAX. - HEAD/SILL CORNERS T 4 w m a o 403 S U io 79" WINDOW WIDTH 4" 3 II II II II D = I� �I II II E II ^ II II v I� II II II -=1===Z: :7 II II II I - �I II i B ` 3 M Ijl i I \ I I I f I I I FALSE MUNTINS 31 1/4" 32 3/4" (SURFACE APPLIED) MAY BE USED D.L. OPG. D.L. OPG. 35 3/8" VENT WIDTH THESE WINDOWS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. Cn W mw dZ ' �o U 3 1/2' MAX. HEAD/SILL CORNERS — m 50:- � _ e w a- g Z w � > 3 111' (2) ANCHORS AT MTG. STILE ENDS TYP. WINDOW WIDTH (4) ANCHORS READ. FOR SIZES AND LOADS MARKED WITH ''' ON SHEET 2 ONLY 10 5/8" MAX. 4y HEAD/SILL 3" m E5 CORNERS c in U II II I� �I I1 /. if /. II II II it �li II II it l I� II II II II = I===41= II II 1 I II II =}II==== = II II I 1 B 3 FALSE MUNTINS 32 3/4' 32 3/4' — EECO—GUARD 9M_9S-200.i (SURFACE APPLIED) ALUM HORIZONTAL ROLLING WINDOW MAY BE USED D.L. OPG. D.L. OPG. 36 7/8' DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER vcuT winTu CHARTS SHOWN ON SHEETS 2. TO QUALIFY FOR SMALL MISSILE IMPACT RATING EXTERIOR PLY OF GLASS TYPE 'C' MUST BE TEMPERED. 1/8" HEAT STREWD. GLASS 1/8" HEAT STREN'D. GLASS 1/8" HEAT STREN'D. GLASS .090' Interlayer .090" Interlayer Trosifol PVB SentryGlas By 'Kuraray America, Inc.' By 'Kuraray America, Inc.' 1/8" HEAT STREN'D. GLASS 1/8" HEAT STREN'D. GLASS SILICONE SILICONE a DOW CORNING 899 GE SCS 2000 a DOW CORNING 899 GE SCS 2000 z m z m z m ! In iO I I II II io is !I 22 If 22 o' AT 1/4 POINTS ON LITES 29 WIDER THAN 36" ONLY GLASS TYPE 'A" AT 1/4 POINTS ON LfrES 29 WIDER THAN 36" ONLY GLASS TYPE 'B' GLAZING OPTIONS 5/16' AIR SPACE HEAT STREW D. GLASS .090" Interlayer Trosifol PVB By 'Kuraray America, Inc.' 1/8" HEAT STREN'D. GLASS CARDINAL XL EDGE SPACER / ST. STEEL SILICONE DOW 899 AT 1/4 POINTS 2s ALL SIZES GLASS TYPE 'C' APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF- H.R./H.R. OR HORIZONTAL ROLLING WITH OTHER WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS USING MIAMI—DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2014 (5TH EDITION)/2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON—METALLIC AND NON —COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2014/2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL `\\\\tIIIIIljf/j/ � A i 1 1 29 SETTING BLOCKS AT LAM. GLASS AND INSUL. LAM. GLASS NOTCH GLAZING BEAD LEG TO CLEAR BLOCKS Eit72If153=+� {;f.K�k 4P rani t)"Jer. 70592 I ' A EOIF i �PfQIIgI\\ os Z N a a� I n. O� Ot M 0 CL 0 g Ogoo ��a Q W M, LL10 Q zW • oo a,r J Z • • °0' 44 W 0 2' C, O 62`I.0' R•1 E5 Z � m N 0 04 U Lon W WDoM' W m P 0 0 o o N a- a O 1 0 7 0 5�^��� or U C U O w w N I 4 N N Fa- o � oU drawing no. W09-12 sheet 1 of 7 DESIGN LOAD CAPACITY - PSF (XO, OX OR XX SIZES) WINDOW DIMS. A W/O REINF. WITH REINF. GLASS TYPE 'A' GLASS TYPE 'B' GLASS TYPE 'C' WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) EXT.(+) INT.(-) 26-1/2" 37' ._53-1/8" 74" (2k 1 (3) 4 70.0 1 80.0 80.0 90.0 70.0 80.0 4 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 8 70.0 80.0 80.0 90.0 70.0 80.0 26-1 /2" 37' 53-1 /8" 74" 38-3/8" (4) 4 70.0 80.0 80.0 90.0 70.0 80.0 4 70.0 80.0r--, 90.0 70.0 80.0 6 70.0 80.0 90.0 70.0 80.0 6 70.0 80.0 90.0 70.0 80.0 26-1 /2" 37" 53-1 /8" 74' 50-5/8' (5) 4 70.0 80.0 90.0 70.0 80.0 4 70.0 80.0 90.0 70.0 80.0 5 70.0 80.0 90.0 70.0 80.0 8 70.0 80.0 90.0 70.0 80.0 26-1 /2" 53-1/8" 74' 63"37" (6) (6) 4 70.0 80.0 90.0 70.0 80.0 4 68.9 77.5 .0 90.0 70.0 80.0 6 70.0 70.0 80.0 90.0 70.0 80.0 8 70.0 70.0 80.0 80.4 70.0 80.0 24" 36" 48" 60" 72" 23) 4 70.0 80.0 80.0 90.0 70.0 80.0 4 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 8 70.0 80.0 80.0 90.0 70.0 80.0 24' 36" 48' 60" 72" 6 - 4 70.0 80.0 80.0 90.0 70.0 80.0 4 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 1 80.0 80.0 90.0 70.0 80.0 8 70.0 1 80.0 80.0 90.0 70.0 80.0 24" 36" 48" 60" 72" 48" s 4 70.0 80.0 80.0 90.0 70.0 1 80.0 4 70.0 80.0 80.0 90.0 70.0 1 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 80.0 80.0 90.0 70.0 80.0 8 70.0 80.0 80.0 90.0 70.0 80.0 24" 36' 48' 60" 72" 6s) 4 70.0 80.0 80.0 90.0 70.0 80.0 4 70.0 80.0 80.0 90.0 70.0 80.0 6 70.0 70.0 80.0 90.0 70.0 80.0 6 70.0 70.0 80.0 90.0 70.0 80.0 8 70.4 70.0 80.0 87.6 70.0 1 80.0 A = NO. OF ANCHORS PER HEAD & SILL () = NO. OF ANCHORS PER JAMB * MAX. LOAD FOR THESE SIZES IS -90.0 PSF WITH (4) ANCHORS AT MTG. STILE ENDS LEFT AND RIGHT VENTS TO BE OF EQUAL GLASS DLO WIDTHS 'XO OR OX' DESIGN LOAD CAPACITY - PSF (XOX SIZES) WINDOW DIMS. A W/O REM. WITH REINF. GLASS TYPE 'A' GLASS TYPE 'B' GLASS TYPE 'C' WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) EXT.(+) INT.(-) 74" 106-1/4" 111 • 26" (3) 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 74' 106-1/4" 111" 38-3/8" (4) 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 74" 106-1 /4" ill, 50-5/8" (5) 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 1 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 74" 106-1 /4" 111" 83" 6 9 70.0 70.0 80.0 90.0 70.0 80.0 12 70.0 70.0 80.0 82.6 70.0 80.0 12 70.0 70.0 80.0 80.4 * 70.0 80.0 72" 84" 96" 108' 24" (3) 9 70.0 1 80.0 80.0 90.0 70.0 80.0 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 72" 84" 36" 108" 36" (4) 9 70.0 80.0 80.0 90.0 70.0 80.0 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 1 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 72" 84" 96" 1O8" 48" (5) 9 70.0 80.0 50.0 90.0 70.0 80.0 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 72" 84" 96" 108" 60' (6) 9 70.0 70.0 80.0 90.0 70.0 80.0 9 70.0 70.0 80.0 90.0 70.0 80.0 12 70.0 70.0 80.0 90.0 70.0 80.0 12 70.0 70.0 80.0 87.6 70.0 80.0 A = NO. OF ANCHORS PER HEAD & SILL () = NO. OF ANCHORS PER JAMB * MAX. LOAD FOR THESE SIZES IS -90.0 PSF WITH (4) ANCHORS AT MTG. STILE ENDS (1/3W) (1/3W) (1/3W) 4- OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH 'XOX' DESIGN LOAD CAPACITY - PSF (XOX SIZES) WINDOW DIMS. A W/O REINF. WITH REINF. GLASS TYPE 'A' GLASS TYPE 'B' GLASS TYPE 'r. WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) EXT.(+) INT.(-) 74" 106-1 /4" ill" 26 (3) 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 1 70.0 80.0 , 2 70.0 80.0 80.0 90.0 70.0 80.0 74' 106-1/4" 111" 38-3/8" (4) 9 70.0 80.0 80.0 90.0 70.0 80.0 12 - - 80.0 90.0 70.0 80.0 12 - - 50.0 90.0 70.0 80.0 74" 50-5/8" (5) 9 70.0 80.0 80.0 90.0 70.0 80.0 74" (fi) (6) 9 70.0 70.0 80.0 90.0 70.0 80.0 72" 84' 96" 1 os" 24" (3) 9 70.0 80.0 80.0 90.0 70.0 80.0 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 72" 84" 96" 1p8" 36' (4) 9 70.0 80.0 80.0 90.0 70.0 80.0 9 70.0 80.0 80.0 90.0 70.0 80.0 12 70.0 80.0 80.0 90.0 70.0 80.0 - - 80.0 90.0 70.0 80.0 72" 84" 96" (5) 9 70.0 80.0 80.0 90.0 70.0 80.0 9 70.0 70.0 80.0 90.0 70.0 80.0 12 70.0 70.0 80.0 90.0 70.0 80.0 72" 60" (6) 9 70.0 70.0 80.0 90.0 70.0 80.0 ALL EXTERIOR(+) LOADS SHOWN ON THIS SHEET ARE FOR WINDOWS WITH ADD -ON RISER AT FRAME SILL FOR STD. SILL (NO RISER) LIMIT EXT.(+) LOADS TO 67.0 PSF SEE SHEET 3 FOR DETAIL. A = NO. OF ANCHORS PER HEAD & SILL ( ) = NO. OF ANCHORS PER JAMB (1/4W) (1/2W) (1/4W) OPERATING VENTS TO BE 1/4 OF THE WINDOW WIDTH 'XOX' NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 Ei3`4 :�accr;canc. �� I i-lI0 .Z3 - Ex2irz:,;�;ral,t�t�-L�t� T •••• J u I s • • In •-06 • w • a PI)LEI •Y• LLJ ' F- VA. �• w» v�' E Z o0 co an m 3 z �, o 0,y�� O 5' U Loo LJ w W Wcomr s TYPICAL ANCHORS r —1 STRUCTURE MIAMI—DADE COUNTY APPROVED MULLION & MULLION ANCHORS SEE SEPARATE NOA IA EDGE DIST. I �N TYPICAL ANCHORS SEE ELEV. FOR SPACING v. 1BY I WOOD BUCK EDGE TYPICAL ANCHORS SEE ELEV. FOR SPACING WEEPHOLES: W1 = 3/8" X 2-1/4" WEEPHOLES AT EACH END AND 37" O.C. MAX. SEALANT: ALL JOINTS, AND FRAME CONNECTIONS SEALED WITH JOINT SEALER`. • I v• v . I TYPICAL ANCHORS SEE ELEV. FOR SPACING H,� TYPICAL ANCHORS SEE ELEV. FOR SPACING WOOD BUCKS AND METAL STRUCTURE NOT BY ECO WDW. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS.: SEE ELEV. FOR SPACING • t1 �4" DIA. ULTRACON—BY `ELCO`' (Fu�177 KSI, F155 KSI) ' INTO 2BY WOOD BUCKS OR WOOD STRUCTURES ' 1-1 /2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS) THRU 1 BY BUCKS INTO CONC. OR BLOCKS : 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) DIRECTLY INTO CONCRETE OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1 /4" MIN. EMBED INTO BLOCKS (JAMBS) 14 SMS OR SELF DRILLING SCREWSt (GRADE 2 CRS) INTO MIAMI—DADE COUNTY APPROVED MULLIONS OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS) (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE ALUMINUM: 1/8" THK. MIN. (6063—T5 MIN.) STEEL: 1/8" THK. MIN. (Fy = 36 KSI MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) (TYPICAL EDGE DISTANCE) INTO CONCRETE AND MASONRY = 2-1/2" MIN. INTO WOOD STRUCTURE = 1 " MIN. INTO METAL STRUCTURE = 3/4" MIN. WOOD AT HEAD, SILL OR JAMBS SG — 0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS Vc = 3000 PSI MIN. C-90 HOLLOW/FILLED BLOCK AT JAMBS f'm = 2D00 PSI MIN. `���111111l�l�' t ftOti? I .70592 C'T a VISED = `( ys "Orasplying With tare Flandr. " Building Cede - ' A_eeptanCC I To • _) cxpiaatior; oat ' 0 TATE OF : ��• ORION Afi�-rxi Da�e Pr:>3ttcf C'o. Srcf '��ef ®�id�� ` �!!lliltlll o w _N I rn Z ao 3 2Z z '• W rt 0O 0 JQ�' 1„ N U IL v0 c~i ,'n m Cmo�� g C IL C A N O Q W n _� LLZ� J t7� J -. ••• � o U .• J • J owe avci c M & w •Y F. Cb •C o 5 N Q MM: W_ Z �� NJ O0 sworn Q r' o� $ r N % O N N o � drawing no. W09 -12 sheet 3 of 7 0 METAL STRUCTURE 1/4" MAX. SHIM TYPICAL ANCHORS SEE ELEV. FOR SPACING --- SCREEN OPT. 2 STEE SEE SHEET 2 FOR CAPACITY WINDOW WIDTH VENT % D.L. 0 —SCREEN OPT XO LAYOUT m EXTERIOR MIAMI—DADE COUNTY APPROVED MULLION SEE SEPARATE NOA WIDTH 0 WINDOW WIDTH XOX LAYOUT TYPICAL ANCHORS r SEE ELEV. FOR SPACING 1 /4' MAX. SHIMS 1BY WOOD BUCKS TYPICAL ANCHORS v,a SEE ELEV. v . FOR SPACING •1 1 f 4" 0 w • v � c 3i1 D.L. OPG. _zA.,Kttc4 Uri. STEEL REINFORCING AS REQD. SEE SHEET 2 FOR CAPACITY --------SCREEN OPT. WINDOW WIDTH U0 U W _N 1 0 LL, N 00 0 0 O -1 N U N Lo LL v(0 m �x� Q ACC .•I NN0 O QWm 4. zN= N Uko 1 /4" MAX. J ,� SHIMS # Z • • M • to 1BY • • 4 •••••• WOOD BUCKS •• W — tl 0E— .. .. .dQ'. iL •••••• TYPICAL ANCHORS • • ;+• } • • • v ° SEE ELEV. o. FOR SPACING U6 to •• �W O00,3iX� ••i••• •• I Z •�r ••••:• • • • 1 1 4 • c. 7.r •••••• v i 0 pp0 v i••••i o • �' W �LLI g w a v r W Z N N ° o g 0 0 o a r r 0 in U j rn rn N r C a •N •- Cl n C •� O O O .- � 0 ��'.•' vCEENSF . ®i N o No 70692 o a as CtSCiijr'P _ J 1S D �2 �'153g wit") 4s'3 F'FS?C{ta BuiWing coda _� e � .• ' � � 1y1 V� u ACC(:y*1uic� !1"• L"'`3 if::Xj:li'i7LiPtE i �iil: � �,j'j l•�C? iq ATE OF •��� � � • ' � drawing no. �,.� W09 -12 1%0 sheet 4 of 7 EDGE DIST. METAL • STRUCTURE EDGE TYPICAL ANCHORS DIST MIAMI—DADE COUNTY APPROVED SEE MULLION &MULLION ANCHORS ' � v SPACING FOR SPACING SEE SEPARATE NOA EDGE DIST. n ALT. TYPICAL ANCHORS SEE ELEV. FOR SPACING O ALT. TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS SEE ELEV. FOR SPACING 1 /4" MAX. SHIMS TYPICAL ANCHORS SEE ELEV. FOR SPACING INSTALLATION DETAILS WITH FLUSH FRAME ADAPTER O ALT. V 0 W N_ �O Z h I rn o O 9 M 9 Z I j 0N OV O a v p yj C It Iz 0 pn.op'mZrx - 1 ZN: .� 30Q a a zmz � N U J I 00 (n • • N tj .•� LLO .. T. >-0_ p W �- �0 Vbo • :••... • a• ,-00 a •• •• • Z .1AQ ••. •.• • • • • • 0 N .. c • • ••.••• Zw5 •.•• -04 PRt?DUC'T REVISED _ No. 592 complying o cdiLh Lie Florida BizOCl.itg CtYde 49 vccep:. ,ceb}L-J)I�Dt �! �•aF on DaneTE OF � � � drawing no. By ��f2�� zhGo %,� . ORION.•����� W09 —12 �,Vami Dade _Pr.-: SAL /ras.�.,tti��� sheet 5 of 7 am= 8 Oi FRAME HEAD 3.876 O2 FRAME SILL 1.314- .340 ji .312 .062 �3 SILL TRACK .5001.187 .062 2.750 2.812 t.874.1687 O MOV. FRAME JAMB 1 1.434 3/16- 12 11 O VENT TOP/BOTTOM RAIL STEEL REINFORCING 2.095 .519-j�--�j � �.130 1.250 --I 1.140 .062 F- -1.344 ---I SO JAMB STILE 7 2.063 - I -1.250 G 1.140 C 062- MEETING RAIL 1 2.185 I - T .719 .045 .803 .045 .803 i - '_� 2.246I � 1.047 ^I 1.047 119 GLAZING BEADS o® 1.340 1.I22 [r; j .062 1.1 2 F -1.375 --I O FIXED MTG. RAIL --i .750 �- 062 2.812 2.750 F� .969 1.688 -�II O FIXED FRAME JAMB 2.688 .062 .500 69 k-- 2.611----�i 28 FLUSH FRAME ADAPTER ITEM PART # QUANTITY DESCRIPTION MATERIAL MANP./SUPPLIER/REMARKS 1 FY201 1 FRAME HEAD 6063-T6 - 2 FY202 1 FRAME SILL 6063-T6 - 3 FY203 1 SILL TRACK INSERT 6063-T6 - 4 FY205 AS READ. MOV. FRAME JAMB 6063-T6 5 FY101 AS REQD. FIXED FRAME JAMB 6063-T6 - 6 FY104 1/ VENT FIXED MTG. RAIL 6063-T6 - 7 FY105 1/ VENT VENT INTERLOCK 6063-T6 - 8 FY206 1/ VENT JAMB STILE 6063-T6 9 FY107 2/ VENT TOP AND BOTTOM RAIL 6063-T6 - 10 FY108 AS READ. GLAZING BEAD (LAM. GLASS) 6063-T6 10A FY110 AS REQD. GLAZING BEAD (INSUL. LAM. GLASS) 6063-T6 - 11 - AS REQD. REINFORCING BAR STEEL - 12 - AS REQD. REINFORCING BAR STEEL - 13 FY204 AS RTEQD. ADD -ON SILL RISER 6063-T6 USE AS REQD. 14 FY208 4/ VENT ROLLER HOUSING & GUIDE CELCON - 15 FY209 2/ VENT ROLLER BRASS - 16 FY210 2/ VENT ROLLER PIN ST. STEEL - 17 #8 X 1" AS REQD. FRAME/VENT ASSEMBLY SCREWS CRS P.H. SMS 18 #8 X 3" 2/ VENT FIX. RAIL SILL SCREWS (SILL END) CRS P.H. SMS 19 W23181 AS REQD. FIN SEAL W STRIPPING - ULTRAFAB 20 030OT190 AS REQD. BULB SEAL Q-LON SCHLEGEL 21 E207 AS REQD. BULB SEAL SANTOPRENE ULTRAFAB, DUROMETER 65±5 22 E203 AS REQD. GLAZING BEAD BULB SANTOPRENE ULTRAFAB, DUROMETER 65A 23 FLB-50 AS REQD. GLASS SPACER SILICONE FRANK LOWE 24 SL203P 2/ VENT SWEEP LATCH - SULLIVAN & ASSOC. 25 #8 X 1/8' 2/ LATCH LATCH INST. SCREW ST. STEEL OH SMS 26 WA2L 2/ WDW. WEEP VALVE - PREFERRED ENG. PRODUCTS - 1/ VENT 5/16' BOX SCREEN - OPTIONAL • t27 28 FY120 - FLUSH FRAME ADAPTER 6063-T6 OPTIONAL • 2g - 2/ LITE SETTING BLOCK EPDM OUROMETER 80±5 SHORE A• is 0 {��/ w M N I m Z phim z Q '19 O, 0 �y rJ U a N 0�ti d0 0ILaa S oet'31 it u) p IL W U) OR QW� .-� N U � J 00 (N • • L0 W 10• "v • Z •� • a O C,625 •o U 0 U3 w W �i c !`R0€311C'T REVISED as ctmmlying witty, the Florida v m v u BUi€i!iJ9 i GO2 i Acce iancc No E OF ��� drawing no. R10- AL1```� sheet 6 of 7 17 I FIXED MTG. RAIL CORNER M. e �� N ULO J Lf) 3r- OD OD c� • LLI LL • r Lj* db �3 oCO .. z !-� 3 aD qO Z•� o o UCOwn W oaM6TT rdw12 � z i K N N n V7 IA V) x O W W ZZQ ZZa O m U U 0 Z Z iL O lalolj6l i3#:{lBE_;i i' REYtS=_t) 7 2 _ o m J� o 0 3 Sc C3lvP]Y i==.g With the Floridan Steil 3tta %e;tiP 0A u Acce.�v;ce i��-lJa1.2g � �9 ®' EOF '.�� drawing no. }.x�+i3 as`ztu3 Vale p.5 � 27 �G� � f} zh o �.� . R4�A.•�.�� W09 —12 3. FY6�1sheet 7 of 7 i11 2.688 .062 1-1 50C 69 2.611—�I 0 FLUSH FRAME ADAPTER 0 FRAME HEAD/SILL/JAMB 750 .81T 3 .O 0 ���III 888 O2 GLAZING BEAD 1.0701 I_� 375 .050 3O ANCHOR COVER iEC0—GUARD SERIES-300 Af I.UMINUM FIXED WINDOW) DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEETS 2. APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF FIX./FIX. OR FIXED WITH OTHER WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS USING MIAMI—DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2014 (5TH EDITION)/2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 1BY OR 29Y WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON—METALLIC AND NON —COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2014/2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL. FALSI (SURFACI wiklhnl„ wirilru MUNTINS APPLIED) D.L.OPG. OPTIONAL A II II C II II 4 II II II iE it II u II i II n u II o II II II II II II I IE II � t I II II I I 11 II II n n 3 i 6" MAX. 12" MAX. THESE WINDOWS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. nLnv/.aiLL ­1 - CORNERS GLASS D.L.O. DIMS. D.L.O. HEIGHT = WINDOW HEIGHT — 3.625" D.L.O. WIDTH = WINDOW WIDTH — 3.625" PRODUCT REVISED ,s Complying With the Florida Building Code AcccpL,j;ice ?Jo 17-LIo Expifatios, Date By Ivtawni Dade ;�,,, „r, ' to �W Ew z �0 U 1) i ENS�••;�d i .7 2 t S YE OF��� H O w h 3 f` N a a 9000`a U IL O 0aoo op Orb 3 N00J Q1zNWmLL - 4 — Q W 0) F .. N o JI 3 � w • V) � � w ,c � • w O a at 4 I A Z3�do �¢ j 0 p ZP O C4J v o! (.5 LLJ od s N �I o � ei � aT m drawing no. W09-20 sheet 1 of 5 3/16" ANN. GLASS 3/16" HEAT STREN'D. GLASS .090" Interlayer .090" Interlayer Trosifol PVB SentryGlas \ �By 'Kuraray America, Inc.' By 'Kuraray America, Inc.' r-3/16" ANN. GLASS \F3/16- HEAT STREN'D. GLASS SILICONE SILICONE DOW CORNING 899 899 I GE SCS 2000 000 z m Z °° I II g j �I LDRNING to II ' j 4 !I !I 5 4 II !IliAT rn 1/4 POINTS i IjAT 1/4 POINTS a ON INLY II IITHAN imi i THAN�36" OES 36" OTES NLY �8 X 1-1/4" SMS �_��8 X 1-1/4" SMS AT 3-1/2" FROM ENDS AT 3-1/2" FROM ENDS AND 10" O.C. MAX. AND 10" O.C. MAX. ',GLASS TYPE 'C') GLASS TYPE 'D' GLAZING OPTIONS W. WIDTH WINDOW WIDTH WINDOW WIDTH i � z z zLAI z n I I o 3 I 3 L- -J WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH I I I z I zLoz 3Iw 1 WINDOW WIDTH WINDOW WIDTH WINDOW WIDTH I I z c� ALLOWABLE LOADS FOR ALTERNATE SHAPES AS SHOWN ABOVE OR SIMILAR CAN BE VERIFIED BY INSCRIBING PICTURE WINDOW SHAPE WITHIN SQUARE OR RECTANGLE AS SHOWN IN DOTTED LINES AND OBTAINING ALLOWABLE LOADS FROM THOSE SHAPES. DESIGN LOAD CAPACITY - PSF WINDOW DIMS. GLASS TYPE 'C' GLASS TYPE 'D' WIDTH (W) LENGTH (L) EXT.(+) INT.(-) EXT.(+) 1NT.(-) 2e 30" 36" 42" 48" 54" 60" 66" 72" 36„ 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 24" 30" 36" 42" 48" 54" 60" 66" 72" 4„ 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.6 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 76.6 80.0 90.0 24" 30" 36" 42" 48" 54" 60" 66" 72" 60„ 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 66.8 71.3 80.0 90.0 60.2 64.2 80.0 90.0 60.2 64.2 80.0 90.0 60.2 64.2 80.0 90.0 24" 30" 36" 42" 48" 54" 60" 72" 1 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 76.6 80.0 90.0 66.B 71.3 80.0 90.0 60.2 64.2 80.0 90.0 24" 30" 36"" 42" 48" 54" 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 70.0 70.0 80.0 90.0 65.6 65.6 80.0 90.0 64.3 64.3 80.0 90.0 24" 30" 36" 42" 48" 96" 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 76.2 80.0 90.0 64.6 64.6 80.0 90.0 59.9 59.9 80.0 90.0 24" 30" 36" 42" 108" 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 74.5 74.5 80.0 90.0 61.5 61.5 80.0 90.0 24" 30" 36" 120" 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 74.5 74.5 80.0 1 90.0 DESIGN LOAD CAPACITY - PSF WINDOW DIMS. GLASS TYPE 'C' GLASS TYPE 'D' WIDTH (W) LENGTH (L) EXT.(+) 1 NT.(-) EXT.(+) 1 NT.(-) 26-1/2' 37" 53-1/8" 74" '` 26" 75.0 80.0 I 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 26-1/2" 37" 53-1 /8" 74" 38-3/8„ 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 26-1 /2" 37" 53-1 /8" 74" 50-5/8„ 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 71.3 76.0 80.0 90.0 71.3 73.1 80.0 90.0 26-1 /2" 37" 53-1 /8" 63" 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 67.9 72.5 80.0 90.0 37" 53-1/8" 76' 75.0 80.0 80.0 90.0 75.0 80.0 80.0 90.0 67.9 69.9 80.0 90.0 • • L • n J % • • • NOTE: WIDTH AND LENGTH DIMENSIONS CAN BE ORIENTED VERTICALLY OR HORIZONTALLY AS SHOWN ABOVE. NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS). ifRODI)C, I'.LSV as Cw : plyipg Wiub1 the IriLiidd Building Code f cccptance i#: �-j�� Expi-ration.F.)3E::rj, 201ct ib iz*tii Rare ; _owvz< i.Cn,ici �,t.TATE .. . �r 92 ; OF A49 .°®��.11 �/ o U w 0 N I rn w a �00 o p�N ♦1. W dot O �H� v o t7 0ILaa p r azz wy Jima Q LLI 0 J J m 3 00 IZZ Ic W • li.l LC • • o U) �f8 • •� ss- 0 r+j •sv C, 0°•_5•1 n Z 3LL. QD Z f� O N Uoo� S W oo •' w 7 N 'j a o ii °o n v` u drawing no. W09-20 sheet 2 of 5 TYPICAL ANCHORS 1BY SEE ELEV. FOR SPACING METAL TYPICAL ANCHORS 2 OOD BUCK WOOD BUCK STRUCTURE SEE ELEV. FOR SPACING OR ' MIAMI—DADE COUNTY APPROVED WOOD RE c a ; a ° 'd. ° a .;.4 • e .a ED F_ DIST, MULLION & MULLION ANCHORS ° EDGE SEE SEPARATE NOA EDGE a I DIST. tj EDGE DIST. N En cn I 3 2 I! !j I! !I TYPICAL ANCHORS TYPICAL ANCHORS SEE ELEV. FOR SPACING SEE ELEV. FOR SPACING it !! WOOD BUCKS AND METAL STRUCTURE NOT BY ECO WDW. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. i i j! !i c� 0 I i x C7 H a _ W l�POP FUN e ° TYPICAL ANCHORS ELEV. a I FOR SPACING ° EDGE DIST. D' 1BY3 °WOOD BUCK EDGE DIST. I TYPICAL ANCHORS SEE ELEV. FOR SPACING ;TYPICAL ANCHORS SEE ELEY. FOR SPACING w WJIL DIA._UIMACON BY_'ELCO,(Fu=177 KSI, Fy=155 KSI) ^• INTO 2BY WOOD BUCKS OR WOOD STRUCTURES _ o J ,Ln 1-1/2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS) J 3 THRU 1BY BUCKS INTO CONC. OR BLOCKS g V} •••�• 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) ••�• 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) .. Ld v N DIRECTLY INTO CONCRETE OR BLOCKS .. o ui • 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) �y . 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) •. •S 3•�. _ �#14 SMS OR DRILLING SCREWS (GRADE 2 CRS) ++ N p o � 1 _SELF INTO MIAMI—DADE COUNTY APPROVED MULLIONS J OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS) 0 N.�'• (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE •• o V SO •1• ALUMINUM: 1/8" THK. MIN. (6063—T5 MIN.) w W� STEEL: 1/8" THK. MIN. (Fy = 36 KSI MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) ATYPICAL EDGE DISTANCE INTO CONCRETE AND MASONRY = 2-1/2" MIN. W INTO WOOD STRUCTURE = 1" MIN. W N N INTO METAL STRUCTURE = 3/4" MIN. ° ; o B o WOOD AT HEAD, SILL OR JAMBS SG = 0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS Vc = 3000 PSI MIN. m ' R C-90 HOLLOW/FILLED BLOCK AT JAMBS f'm — 2000 PSI MIN. z $ SEALANT: ALL JOINTS AND FRAME CONNECTIONS SEALED WITH JOINT SEALER. t�Oda r^•uud:s� �o Ex Ry- P. EN � I N .7 y j �n TATEOF drawing no. sheet 3of 5 ITEM PART # REQD. DESCRIPTION MATERIAL MAN'•/SUPPLIER/REEKS 1 FY301 2 FRAME HEAD/SILL/JAMB 6063-T6 - 2 FY302 AS REQD. GLAZING BEAD- 7/16" GLASS 6063-T6 - 3 FY303 AS REQD. ANCHOR COVER 6063-T5 - 4 E203 AS REQD. GLAZING BEAD BULB NEOPRENE ULTRAFAS 5 FL13-50 1 GLASS SPACER - 1/8" HIGH SILICONE FRANK LOWE 6 #10 x 1" 8 FRAME ASSEMBLY SCREWS CRS PH SMS 7 FY120 - FLUSH FRAME ADAPTER 6063-T6 OPTIONAL 8 - 2/ UTE I SETTING BLOCK EPDM DUROMETER 85±5 SHORE A MIAMI-DADE COUNTY APPROVED MUWON SEE SEPARATE NOA TYPICAL ANCHORS TYPICAL ANCHORS SEE ELEV. FOR SPACING RECT. OR SQUARE WINDOWS TYPICAL ANCHORS ;EE ELEV. 'OR SPACING CIRCULAR WINDOWS CORNER DETAILS 1/4" MAX. 1 /8" THK. ALUM STRAP WELDED JOINTS TYPICAL ANCHORS SEE ELEV. FOR SPACING METAL STRUCTURE aS ri; �ptss•c�'11 110Z Z!i U0 4. w O N I 6 Z ti rn 3 / o °y1 z al a I G 0 rj P U 0C 0 Nh v Q�e'I 0a 00Q 8 \ 04 � U) 0 XZ a W =LL �p �zw -0 �oo j a ul m � v N O I � R*ego J LO MITER CORNERS • ••M• • VJ • �i ••• • . � t9 � cnJ•o. - • s � p .. .wla o �. �;• • • �i Z 3 LL. • Z�• L• • • I 0 C-44 o U W W a] k • • b U m0 T = m m In In W a n W N N o 0 Laa I o 7 92 _ a ATE OF W drawing no. � .L®RID�..��o�; w09-20 ��6 �®�1;; 0 (sheet 4 of 5 METAL TYPICAL ANCHORS STRUCTURE SEE ELEV. FOR SPACING TYPICAL ANCHORS MIAMI-DADE COUNTY APPROVED o D n v I SEE ELEV. FOR SPACING MU LISEPARAMU MULLION ANCHORS NOA EDGE' DI Q, v EDGE EDGE DIST. DIST. ..... a e. A ALT. O ALT. to I TYPICAL ANCHORS EDGE DIST. i SEE ELEV. FOR SPACING TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS SEE ELEV. FOR SPACING INSTALLATION DETAILS WITH FLUSH FRAME ADAPTER n O W a N I rn Z 3 Oko z IFFFF LLI m Q "C N I �.pp`g O N �a LL 0 t R m 0aLi� 0'0� g paeo �yU)0 Q w a >i 6 LL z_ H � N O v J N I 3 DD in OD 3t '^ ••o VI • w �s • • is �. O L •• 0 00.5:� Z L- .. • b 3 Z�•a �J • O M • W ••. 4i lz at i U u) w E N_x _h yY�j to 0 z z z 7 ```,�Lrirrrll//// ♦� �A� /// CD . E►dSF'' N Q as r..otnp1•yirg ta;.t}? the F1a:;t3:s 7 'Z 1'i'i ildlt.3R Leo m Yi m a By Si !1R ��Q� � ®• TATE OF � . ki drr%owiinng �%no. �'iiami 'a&.t �� ro.-Jzl [ - jrtir.tii �j �'• e®IR4®�. '•�z � t T O J LO ♦� �F®IVAb, ���♦♦ sheet 5 of 5 ////IIIIIrS�� SERIES 6600) {.AL'—UMIN—-OUTSWING ENTRANCE DOOR SINGLE (X) AND DOUBLE (XX) LEAF DOORS SEE SHEET 2. STAND ALONE SINGLE SIDELITE SEE SHEET 3. SINGLE AND DOUBLE LEAF DOORS WITH SIDELITES SEE SHEET 3. LOWER VALUES FROM SIDELITE CAPACITY CHART OR DOOR CAPACITY WILL APPLY TO ENTIRE SYSTEM. DOORS APPROVED FOR INSTALLATIONS WHERE WATER INFILTRATION RESISTANCE IS REQUIRED. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 1BY'OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON—METALLIC AND NON —COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL. 1/8" HEAT STREN'D. GLASS .090" Interlayer Trosifol PVB By 'Kuraray America, Inc.' 1/8" HEAT STREN'D. GLASS SILICONE z m DOWSIL 899 z N i0 � rn 26 i0 3/16" HEAT STREN'D. GLASS .090" Interlayer Trosifol PVB By 'Kuroray America, Inc.' 3/16" HEAT STREN'D. GLASS SILICONE DOWSIL 899 14 14 8 i ii 8 li li 34 0 I I I I Lu SETTING BLOCKS AT LAM. GLASS �•i _ READ. FOR WIDTHS EXCEEDING 36" ONLY NOTCH GLAZING BEAD LEG TO CLEAR BLOCKS GLASS TYPE lui z 00 N 10 g \ 0 rn GLASS TYPE 'G2' 1/8" TEMP. GLASS 75/16" AIR SPACE 1/8" HEAT STREN'D. GLASS .090" Interlayer rSaflex Clear And Color Glass 1 By 'Eastman Chemical Co.' 1/8" HEAT STREN'D. GLASS [THESE DOORS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. UTTERS ARE NOT REQUIRED. SILICONE DOWSIL 899 CARDINAL XL EDGE SPACER ST. STEEL I 35 � SILICONE SETTING BLOCKS AT INSUL. LAM. GLASS NOTCH GLAZING BEAD LEG TO CLEAR BLOCKS +PRODUC P REVIWA so e�ptying with the F7oEW handing Code AoeepanceNo —G3*Z3 Eipinwi a �Iw6 itii lbfvioet C d .70592 1 2018 A EOPNAL �2p� VO U w w 0 I N Z j o� W co Z F to Q I d a o_ �. 0 0 U 0 0 J N XX G LL 0 V N M VoW� C'O'-M o 0 aco (1) fl)o Q W j LL �ZN -o j 50 < Q W M F N J I o J•••• to 00 • • ao o..••• 00 w • In LA H • ? W ��• N �• Z N•01 N 0 j u-) Q Z4. w Z •te— g W o c0 • M W a�. U w W 00 LU (N (sheet 1 of 9 )( 39 3/4" MAX. FRAME WIDTH 12" MAX. 5" MAX. F456 HEAD/SILL A SILL CORNERS n / u II / II II / I I / II II 00 -00 / m x MLu x r co I (0 Li (O oo a ----ij----- LL \-- 11----- II \ II \ II II \ II I II \ II ACTIVE SURFACE APPLIED FALSE MUNTINS OR 26 15/16" DECORATIVE GRILL D.L. OPG. MAY BE USED 37" MAX. LEAF WIDTH (X) LOCK OPTIONS #1 OR #2 (OPTION 2 SHOWN) SEE SHEET 7.1 FOR DESCRIPTION ® x Ln ® M N i wui m x M rn w 2 CO Q u- 76" MAX. FRAME WIDTH HEAD & SILL ANCHORS AT STILE ENDS (4) AT 3" O.C. 12" MAX. 5" MAX. HEAD HEAD/SILL /� _ _ _ SILL ,� CORNERS I I I !/I I II II \ C----��71 -- \ LOCK OPTIONS #1 OR #2 \ (OPTION 2 SHgW x (7 m SEE SHEET 7.1 FOR DESCRIPT10� (L r L5 0 -----LL---- 11 B I I INACTIVE ACTIVE Q cn m 2 N 5" MAX. HEAD/SILL CORNERS (n 00 w APPLIED I II I I I I I I N � m m Z SURFACE APPLIED a SURFACE 26 15/16" 26 15/16" < x FALSE MUNTINS OR FALSE MUNTINS OR o o (o U DECORATIVE GRILL D.L. OPG. D.L. OPG. 0 DECORATIVE GRILL MAY BE USED MAY BE USED 37" MAX. LEAF WIDTH (XX) DOORS LOAD CAPACITY - PSF SINGLE DOORS (X) DOOR DIMS. LAMINATED GLASS FRAME WIDTH LEAF WIDTH FRAME HEIGHT EXT.(+) INT.(-) 39-3/4" 37" 98" 70.0 DOORS LOAD CAPACITY - PSF DOUBLE (XX) DOOR DIMS. LAMINATED GLASS FRAME WIDTH LEAF WIDTH FRAME HEIGHT EXT.(+) INT.(-) 76" 37" 98" 70.0 75.0 GLASS D.L.O. DIMS. D.L.O. HEIGHT = FRAME HEIGHT - 11.125" D.L.O. WIDTH (X DOORS) = FRAME WIDTH - 12.813" D.L.O. WIDTH (XX DOORS) _ (FRAME WIDTH - 22.125")/2 NOTE: EGRESS REQUIREMENTS TO BE REVIEWED BY BUILDING OFFICIAL. NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05—DEC-219 37 3/16" MAX. FRAME WIDTH 12" MAX. HEAD SILL 32 3/4" D.L. OPG (0) STAND ALONE SINGLE SIDELITE SEE SHEET 3 FOR CAPACITY vQ0DUC r REVISED gia ocetptyr g with the FIortM b1111dieg Qedo Aoecptimce No �" D 3 i • / 3 ispinitio. cfAu�.{_,z,a.Z 11 IQ kab,° con" V° U w w 0 1 N Z 0i M N Q W I Q i a tL - 2 O WO`M O N ct L O �yh LLJ ri C0 >m o p L 0 g O 03 rr O N Q W D U. Zy o M Z10< w Q W m I- fn N U N N ' `� J I O J•••• In • •ao •••• ELY w w Li • • • �.• • • ca � Sp • ••• z N .. o 00 eyl) cul . • • • .� p 00 '..zi 00 �n 0 3•z kn • • A o N W �•Q2• • z (W W co o 11 \�11\1111►,,,,, or- ®�70592 i 0, S TE C?j ®SAL 111111111 (sheet 2 of 9 )1 DESIGN LOAD CAPACITY - PSF STAND ALONE SINGLE SIDELITES SIDELITE FRAME WIDTH INCHES SIDELITE FRAME HEIGHT INCHES WITHOUT REINFORCING EXT.(+) INT.(-) 24 30 36 37 42 82 70.0 75.0 70.0 75.0 70.0 75.0 70.0 5.0 61.7 6.1 24 30 36 37 42 86 70.0 F75.0 70.0 5.0 70.0 75.0 70.0 75.0 61.7 66.1 24 30 36 37 92 70.0 75.0 69.8 69.8 64.1 64.1 1 63.3 63.3 24 30 36 37 98 1 63.3 63.3 57.8 57.8 53.1 53.1 52.4 1 52.4 I � Fil 71 SINGLE SIDELITE WIDTH - DESIGN LOAD CAPACITY - PSF SIDELITES WITH SINGLE OR DOUBLE LEAF DOORS (SEE NOTE BELOW) SIDELITE FRAME WIDTH INCHES SIDELITE FRAME HEIGHT INCHES WITHOUT REINFORCING WITH REINFORCING EXT.(+) INT.(-) EXT.(+) INT.(-) 24 30 36 37 42 82 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 61.7 66.1 61.7 66.1 24 30 36 37 42 86 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 61.7 66.1 61.7 66.1 24 30 36 37 92 70.0 75.0 70.0 75.0 69.8 69.8 70.0 75.0 64.1 64.1 70.0 75.0 63.3 63.3 70.0 75.0 24 30 36 37 98 63.3 63.3 70.0 1 75.0 57.8 57.8 70.0 75.0 53.1 53.1 70.0 75.0 52.4 52.4 70.0 75.0 REINFORCING AS READ. SEE CHART 39-3/4" MAX. (SINGLE) 76" MAX. (DOUBLE) DOOR FRAME WIDTH NOTE: FOR DOORS CAPACITIES SEE SHEET 2. FOR SIDELITE CAPACITIES SEE CHART ABOVE. LOWER VALUES FROM DOOR OR SIDELITE CHART WILL APPLY TO ENTIRE SYSTEM. GLASS D.L.O. DIMS. D.L.O. HEIGHT (SIDELITE) = FRAME HEIGHT - 1 1.000" D.L.O. WIDTH (SIDELITE) = FRAME WIDTH - 4.438" 00 m 148" MAX. TESTED FRAME WIDTH HEAD & SILL ANCHORS AT STILE ENDS CLUSTER OF (4) AT 3" O.C. 6" (4) ANCHORS AT HEAD/SILL 12" 5" MAX. 3" MAX. EAD/SILL P. SEILALD :ORNERS II II II i I I = II II I I _ /ly 'XI.' / II/� I I H//_ = e \ V. /� W d � a o // ILLi 00 J j{ II �/ I I t0 LL// to J �/ 0 ===--11----- ----L----- I I °' 00LLJ p --Ir----- \--------- II / Ld II II I \ I II II II \ II LO K 041O S I I I I I I I I\ II I I 1 (01 OR/#2 ITJON 1 S AOIA 4) II II II \ I I I I SE SHEET 11 Fp / DESCRI ION ' I I Ci B I I I I I I I I I - INACTIVE 11 ACTIVE SURFACE APPLIED FALSE MUNTINS OR _/ DECORATIVE GRILL MAY BE USED 32 3/4" D.L. OPG SIDELITE FRAME WIDTH MAX. SEE CHART AT LEFT 26 15/16" 26 15/16" D.L. OPG. D.L. OPG. 37" LEAF WIDTH 39 3/4" MAX. (SINGLE) 76" MAX. (DOUBLE) WIDTH (OXXO) MAX. UNIT TESTED FRAME AREA NOT TO EXCEED 100.72 SQ. FT. PER FBC 2014 NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 QRODUC f REVI" "Comply 9 with tilt Florist balding Code AoceptanceNo 1$-Q3 •13 fE&FIlmdes Wle `�11111111//��' p® A�4f i 5 2Q T OF 0 rn m V0 U w ao 0 :faI N Z MCO j 0Z C4 m H MQ Q 2 N d IL 00 W N M u. 0 VNh v O W rl 0' 0 '- tM�l 0 0 IL 0 NNE td W D L N W y . 0 J �tOQ j Q W 00) f N o I � J•••• 00 O• • OODD o •••• w �0�• • Z a•••••M Ld 4, l) w 40f• z UZ .0' 0 c •� M 0 coJ Lo < 4a 2 00 �'Z�• o callo v N W 00 M (sheet 3 of 9 1 9/16" MIN. THROW BOLT EDGE DIST. PENETRATION p ° s ° ° 0 � I I I I I I I I I I I I I 1 I I I I I I I I I I I I I I I I I I I I I 11\,1, J v /EIDGE DIST. 1 /2" MIN. THROW BOLT PENETRATION TYPICAL ANCHORS SEE ELEVATIONS FOR SPACING GLAZING OPTIONS SEE SHEET 1 1 s 2 � N ° a TYPICAL ANCHORS SEE ELEVATIONS FOR SPACING PROPERLY SECURED 2BY WOOD BUCK EDGE DIST. 1 BY WOOD BUCK OR WOOD STRUCTURE a� EDGE DIST. METAL SEE NOTE SHEET 1 STRUCTURE a EDGED EDGE DIST. ab a' e 7TjYjPICAL w<0N O N OfNc mwto wcn WCHORS TYPICAL ANCHORS TTaYPIC�A�LA�NICHORS IONS SEE ELEVATIONS VATIONS FOR SPACING FOR SPACING FOR SPACING iBY OR 2BY WOOD BUCKS AND METAL STRUCTURE NOT BY ECO WINDOWS ,BUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. ;TYPICAL ANCHORS:) SEE ELEV. FOR SPACING 111/4" DIA ULTRACON BY 'ELCO')(Fu=177 KSI, Fy=155 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN. PENETRATION INTO WOOD (HEAD/JAMBS) THRU 1 BY BUCKS INTO CONC. OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/JAMBS) 1-1 /4" MIN. EMBED INTO BLOCKS (JAMBS) DIRECTLY INTO CONCRETE OR BLOCKS 1-1 /4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) !j14 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) INTO MIAMI-DADE COUNTY APPROVED MULLIONS OR INTO METAL STRUCTURES (HEAD/JAMBS) (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE ALUMINUM: 1 /8" THK. MIN. (6063-T5 MIN.) STEEL: 1/8" THK. MIN. (Fy = 36 KSI MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) ATYPICAL EDGE DISTANCE INTO CONCRETE AND MASONRY = 2-1/2" MIN. INTO WOOD STRUCTURE = 1" MIN. INTO METAL STRUCTURE = 3/4" MIN. WOOD AT HEAD OR JAMBS SG = 0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN. C-90 HOLLOW/FlLLED BLOCK AT JAMBS f'm = 2000 PSI MIN. x 0 w rr------------------� j I MIAMI—DADE COUNTY APPROVED I I I CLIPPED MULLION I SEE SEPARATE N A II II �I I� TYPICAL ANCHORS SEE ELEVATIONS FOR SPACING V° U w ao fq�lllll 0 I N Z c j 0 Z of H cNIL o a Yi 00`Op O 0 N v U LLI 1= 0 tNti 0 p La •i cy0>In o 0 aoa 0 Nyp(D Q W DLL Z 0 • O J � ID j QW0 — CO J LO I Lo O • •ao 00 0.0000 • • w • �o •••• • Li? •••• V) w• ••• iz }•� • ••• z F•• V) •••• .� 3 •••• •m o. iA 7Q •• O i`••!S. Z� O • •• •O -lp .� M.. W °•LR. W LJ N QitODUC f REVLWO z W1id the F iOFW m z m W as CYmplyipg nts • 13 U a o n e No ` ppisoc� D"te--^'30` �1 � N v WW '^ N stir a o WW o w V a ~ a ~ _ a Zi a o m D x D z N N if] N n c 2 0 N N O DOOR DETAILS C M r .70592 _ d O y �= a m v` TE OP �4�� drawing no. /// I I It I% \\` sheet 4 of 9 1/4" MAX. CONCEALED FLUSH BOLTS O 1/4" MAX. SHIM O LEVERS AT STILE FACE SHIM 3 BY WOOD BUCK TYPICAL ANCHORS SEE ELEV.1 16 ACTIVE LEAF FOR SPACING F v" N o F TYPICAL ANCHORS - - - j SEE ELEV. w w FOR SPACING a s 3 25 23 EXTERIOR 19 9 D.L.O. METAL STRUCTURE 37" MAX. SEE SPEC SHEET 4 LEAF WIDTH LOCK OPTIONS #1 OR #2 39 3/4" MAX. (OPTION 2 SHOWN) SEE SHEET 7.1 SINGLE DOOR FRAME WIDTH FOR DESCRIPTION 1/4" MAX. . O SHIM''.' CONCEALED FLUSH BOLTS CONCEALED FLUSH BOLTS 3 LEVERS AT INSIDE FACE OFSTILE LEVERS AT STILE FACE TYPICAL ANCHORS SEE ELEV.° ° FOR SPACING 16 INACTIVE LEAF 26 13 26 24 Cfl LJ W . 4 ° d 23 .. 13 25 9 11 10 D.L.O. D.L.O. 19 LEAF WIDTH LOCK OPTION A2 EXTERIOR LEAF WIDTI 76" MAX. DOUBLE DOOR FRAME WIDTH 2 POINT LOCK ASSEMBLY 4 POINT LOCK ASSEMBLY � I INACTIVE LEAF ACTIVE LEAFI EXTERIOR DOOR DETAILS — 0 U w co 0 I N Z ti 3 O Z o / M N Q W I 0w Dot U. 0 :011 M V p ui .i a o Im o Oac<A yNm tp ittY Z 9N W D U. a W y IL o z0-g �Wfu Q W m f F N 1/4" MAX. () rn J u' SHIM i Oto • •a0o • • 2BY WOOD B K•• Z =••••.pj OR •••• 4� .. WOOD STR TUFT& • s z N • ACTIVE LEAF EE NOTE HEET•1•. ``' • • co h• ip • • -*,-a • Z (!1 R7 •••• 'o On"r U) ••.• •� 0 00 J ul) • • •� Z. m O ::WoZ •�1� = w • • •O O .. o:N o w N W 00 TYPICAL ANCHORS SEE ELEV. FOR SPACING PRODUC f ItEVIS" ea emptying with the F%G" I;"ng Cede Aoceptaece No G 319 - 3 x1piralira Date1 i 'z-o l �1 � �l�•' CIENSF ° �® �i .705 2 AR 2018 W. T OF i OR �.•°°�D `� (sheet 5 of 9 )I TYPICAL ANCHORS 1 /4" MAX. O 1 /4" MAX. SHIM 5 SHIM 1BY WOOD BUCK TYPICAL ANCHORS . SEE ELEV. FOR SPACING 16 v b ' v TYPICAL ANCHORS o SEE ELEV. FOR SPACING 14 EXTERIOR ° 14 D.L.O. METAL STRUCTURE SEE SPEC SHEET 4 42" AT 86" HT. 37" AT 98" HT. MAX. SINGLE SIDELITE WIDTH DNS REINFORCING #12 SMS O 0)SEE 18 AS READ. SHEET 3 1/4" MAX. '•. AT 5" FROM ENDS SHIM AND 11" O.C. MAX. 5 6 3 ,a 16 i _J 16 I 26 13 I I 24 . . II TYPICAL ANCHORS IU- SEE ELEV. w „ 714 FOR SPACING > 11 3 23 15 25 D.L.O. 19 9 EXTERIOR LEAF WIDTH 39 3/4" (SINGLE) SIDELITE WIDTH _ 76" (DOUBLE) RS FOR 5VAILANU MAX. DOOR FRAME WII VU U W 0 0 I N ^� ao O Z W � H cNo Q I as �� 0060 M O wN`x IL W 0 �Rm O' . E M 8 paOo.1 O NN0 tV W Q � LL N W to- O J ZM W Q W Off H N U 0 ' v J J•••• i o m • • • • w LoLLf • • E • w LLJ ••• • C7 >04W • 'A f•+cp • • • ••• z 3IN Lo ••.•• • • .. . p (Do co In •..••• .... 00 Ith 2 LL, • .. • y W Cam I F N ZW W U � w � m O N U 1 W K 2 D.L.O. V a i a w< N Zi o Zi a a x z x D ill N 1 n 1'2_ C 6 N N m 0 N 0 0 0 MAX. UNIT FRAME WIDTH `J — pRODUC f REYi1 \` • `� ��� M `II Q for complying with the Ffoiiit EWS� bwding Colo A•eeptnecc No a 31 • I S . 70592rttvis-w" Date _ a ` P2018 O U Y T E OF drawing no. SIDELITE DETAILS g ° • �< 1®�.• °moo.`' W12-08 /'11/S ?/O ��1/,B�III 0\ sheet 6 of 9 ITEM # PART # REQD. DESCRIPTION MATERIAL MANF./SUPPLIER/REMARKS 1 E601 - DOOR FRAME HEAD/SILL 6063-T6 - 2 E602 - FRAME COVER 6063-T6 - 3 E603 - DOOR FRAME JAMB 6063-T6 - 4 E604 - SIDELITE TOP & BOTTOM FRAME 6063-T6 - 4A E626 - SIDELITE 9" BOTTOM FRAME 6063-T6 - 5 E605 - SIDELITE FRAME JAMB 6063-T6 - 6 E606 - SIDELITE SLIP ON JAMB 6063-T6 - 7 E607 - LEAF TOP & BOTTOM RAIL 6063-T6 - 7A E625 - LEAF 9" BOTTOM RAIL 6063-T6 - 8 E608 - LEAF W'STRIP ADAPTER 6063-T6 - 9 E609 - LEAF HINGE STILE 6063-T6 - 10 E610 - LEAF LOCK STILE 6063-T6 - 11 E611 - LEAF ASTRAGAL STILE 6063-T6 - 12 E612 - LEAF ALIGNMENT BRACKET 6063-T6 - 13 E613 - LEAF CLAMP 6063-T6 4-1/4' LONG 13A E613 - HINGE BACK-UP PLATE 6063-T6 12" LONG 14 E614 - GLAZING BEAD (5/16" LAM. GLASS) 6063-T6 - 14A E109 - GLAZING BEAD (7/16" LAM. GLASS) 6063-T6 - 15 E615 - GLAZING BEAD (INSUL. GLASS) 6063-T6 - 16 E616 - SNAP COVER 6063-T6 - 17 E613 - BOLT SUPPORT 6063-T6 NOT SHOWN 18 - AS REQD. SIDELITE MULLION REINFORCING 6063-T6 - • 19 FD-107 3/ LEAF BUTT HINGES ALUMINUM SULLIVAN & ASSOC. • • 20 FB1202 - FLUSH BOLT LEVER - SULLIVAN & ASSOC. • • •; 21 FBR914SS - CONCEALED FLUSH BOLT ROD ST STEEL SULLIVAN & ASSOC. 22 #12 SMS AS REQD. FRAME ASSEMBLY SCREWS - - 23 #12 X 3/4" - HINGE INSTALLATION FASTENERS - FH SMS • • • • • 24 _ - 3/8" DIA. THREADED ROD STEEL - 25 W11323 - PILE W'STRIPPING WOOL ULTRAFAB • • • • 26 E20618-KN-3020 - BULB W'STRIPPING SANTOPRENE EPDM • • 27 E206 - GLAZING BEAD BULB SANTOPRENE ULTRAFAB • • 28 - - GLASS SPACER SILICONE FRANK LOWE RUBBER CO. 29 E622 - FLUSH BOLT CUP NYLON - 30 DL01RC - BLACK BOLT SUPPORT BLOCK POLYETHYLENE INTERLOCK 31 DL01WB - WHITE BOLT SUPPORT BLOCK POLYETHYLENE ACME PLASTIC 33 #10 X 3/4" 2/ ADAPTER FH SELF DRILLING SCREWS - - 34 - 2/ LITE SETTING BLOCK, 1/4" X 1/2' X 4" LONG EPDM AT 6" FROM EACH END, DUROMETER 80±5 35 - 2/ LITE SETTING BLOCK, 1/4" X 3/4' X 4" LONG EPDM AT 6' FROM EACH END, DUROMETER 80t5 SEALANTS: ALL JOINTS AND FRAME CONNECTIONS SEALED WITH SCHNEE MOREHEAD JM5504 SEALANT. DRODLIC f 9EVIM as oampwag with the Rod& balding Cede Aweptance No / _a3 • ! 3 Espiratiea Date 34,1Al d is 1 •':�- w v awr Pm"d cell" `\111IIIII►Iit/ �j� •'' 1arENS F .7 %2 5 201uR* T E OF s rl O w ao 0 I N Z O °f F M� a W Z 1 NCL 00 0 0 N Fo. LL O �i�h 0 O W rl >m 0 O a C 0yy�to Q W 7U N W to —. 0 �0m Q w 9 rW- N J LO •••• 00 o • LLJ 05.... o z • z W (n cP (rAA z of � �! t(AD 04 0• f- 3 t M 04 o o �j m 0 m 25 , Z 3 00 0000 o • o•• o co • N J w Lg)c)&Qcr- (sheet 7 of 9 1 LOCKS: OPTION # 1: ACTIVE LEAF: 4 POINT LOCK ASSEMBLY DL01-6007 BY 'INTERLOCK USA INC.' (2) LOCKING POINTS ENGAGING AT INACTIVE LEAF AT STRIKE PLATE 1/2" DIA. THROW BOLT (1) AT TOP ENGAGING FRAME HEAD AND (1) AT BOTOOM ENGAGING FRAME SILL THROW BOLTS ATTACHED TO LOCK BY 3/8" CONNECTING RODS LOCK HANDLE LOCATED AT 42-1/2" FROM BOTTOM INACTIVE LEAF: 2 POINT LOCK ASSEMBLY BY 'INTERLOCK USA INC.' 1/2" DIA. THROW BOLTS AT TOP AND BOTTOM ENGAGING FRAME HEAD AND FRAME SILL THROW BOLTS ATTACHED TO LOCK BY 3/8" CONNECTING RODS LOCK LOCATED AT 42-1/2" FROM BOTTOM I / I I / I / I I / I / I I I \ LACTIVE \ I I \ I \ I I I HINGES: I I �r I I ij I I I I I I INACTIVE ACTIVE 3-1/2" X 7-5/8" X .122" THK. EXTRUDED ALUM HINGE PART #FD-107 BY SULLIVAN & ASSOC. 3 HINGES PER LEAF BOTTOM HINGE AT 10-1/4" FROM BOTTOM TOP HINGE AT 11-3/4" FROM TOP CENTER HINGE AT MIDSPAN (38" O.C. MAX.) HINGES FASTENED WITH #10 X 1" FH SMS (5) SCREWS AT HINGE STILE (6) SCREWS AT FRAME JAMB OPTION #2: ACTIVE LEAF: CONVENTIONAL DOOR LOCKSET WITH HANDLE DELTA 690 BY 'KWIKSET' LOCATED AT 39-1/4" FROM BOTTOM KEY OPERATED ON EXTERIOR AND THUMB TURN ON INTERIOR THROW BOLT LOCATED AT 44-3/4" FROM BOTTOM CONCEALED FLUSH BOLTS BY 'SULLIVAN & ASSOC.' 1/2" X 2" THROW BOLTS ENGAGING FRAME AT HEAD AND SILL MANUALLY OPERATED LEVERS MOUNTED ON STILE FACE LOCATED AT 10-5/8" FROM TOP AND BOTTOM LOCK FASTENED TO STILE WITH (2) #8-32 X 1/2" FH MS INACTIVE LEAF: CONCEALED FLUSH BOLTS BY 'SULLIVAN & ASSOC.' 1/2" X 2" THROW BOLTS ENGAGING FRAME AT HEAD AND SILL MANUALLY OPERATED LEVERS MOUNTED ON INSIDE FACE OF LEAF STILE LOCATED AT 10-5/8" FROM TOP AND BOTTOM LOCK FASTENED TO STILE WITH (2) #8-32 X 1/2" FH MS Ij ACTIVE II FF/ \ • INACTIVE ACTIVE !RODUC f REVISED is empbuz with the FI«i& g � Aecep iLa .lei Rees trance No Etpirr ** Date j 7.4LC1 &Ac-(e.,%. •. 1A e. u �— Q; A ' 922018; ®T OF � ° °• ORE P:•°°� .0�; V0 U W m 0 I N Z toD 3 0 Z � "' m / , C a w Q N a 0 W N` O O M v doW LL 0 r'n ti V O w `I 0' 0 '- n o 0 IL 0 0 y(n0 O (0 N QZi W j LL V) LL Z y - o 30f aOOQ J itW 0) N I O M ~ U L o H v u drawing no. W 12-08 sheet T l of 9 4.000 . 708 1.625 DOOR FRAME HEAD/SILL 4. 25 SIDELITE TOP & BOTTOM FRAME .078 �'329 LL�--1.812 2 FRAME COVER �{ .687 I .050 1.197 II� .154 is SNAP COVER 1.500 - -�L-.625 4.000 7 .078 2.097 DOOR FRAME JAMB 1 750 .519 � -�j�i� .394 � j- .130 .803 ::C.045 .803-I-�{Fo- .05I 0 .803 .045 4.031 078 1.047 1.047 1.172 0 2.081 1.507 4.750 1.507 LEAF TOP/BOTTOM RAIL LEAF HINGE STILE 5.344 4.000 .078 -j LEAF LOCK STILE LEAF ASTRAGAL STILE r 1.500 71s .078 4.000 II II 1.507 SIDELITE FRAME JAMB 7 2.081 8 to GLAZING BEAD 5/16" GLASS 7. 14A GLAZING BEAD Is GLAZING BEAD 7/16- GLASS INSUL. GLASS 12 9" BOTTOM RAIL 4A SIDELITE 9" BOTTOM FRAME 1.500 312 .062 8 LEAF W'STRIP ADAPTER 094 .312 .442 1.584 t2 LEAF ALIGNMENT BRACKET -I 375 .125 1.574 13 LEAF CLAMP �G HINGE BACK-UP PLATE 1 1.250 r .7t9 4.188 .078 SIDELITE SLIP ON JAMB 281 3. 18 SIDELITE MULLION REINFORCING DRODUC t REY65O tic complying with the Florin $*thug code AeceptMcc NQ - • r 3 1i ow 4x4W W&* pAdw<CO~ V° w co 0 I N go 0� �,1$ M z ' � N N a Q I a Op�0 O 0 N M U act 0 �Hh r 0'0 m o 0aoo.°i 0 NNE 0 aW�LL� IL U1 0 - 902 to 0 0 Q W 0) H � N J J in Co J ,) 00 o • • • • W t%�••.• ,3 o •...v •.•• N • h► 01 L 01 ••••• • • •. •.• • I.- � o O �Mj•�N •.••• •• •• 0.c I J •••••• • •. •.• • ? a Z �•d,L 0000 •• • r 0 ..•••• • • • • o co •4• NJ :•..•� N WVE ~ Ci L L 0 Ci w w w m w x x x w x N VI N ^ Vl H f F N H v W W W 0 z w U U U A 0 0 0 m 0 z z z m z ��� ��•' �►G8N3�'• /i n M o i i c0 a .70592 - ? y MAR 2018 �® 08 �� drawing no. //,����®LLLL►1��`` sheet $ of g a uuum rmtAmL %,unuc- r� LEAF CORNER SIDELITE FRAME ' CORNER - 22 SIDELITE MULLION SLIP ON JAMB CORNER VL) 22 U w no 0 OD N Z M 3o� / o Z Cl)N Q Q 2 ry IL I d 0 0 o 0 GLLI ARM v pniI"; 0'0M --o 0 a.d< q 0 0 Q WZ� n �Z1n -o Z Mi a W Q W m rL !- (V V o J 01 LAD _j o .J to O •••• DDo o • • • w �•••• 2 •••••• • • U O • •••.. F• w •.•..• • z •••• Z i•� c�0• • • • i� •••• • •� rn ••••• t r7 rn • • •• •• 0•�i ••••i• ••••• J Z •LL OC) • • 1Y�0 •••••• • LI I • • (D • v • • N W E H w~L to U f 2 W M m 2 p (A M r N O O = r W N •RODVC rS$YIIBm a w z Ir o w r• complying wit% tye.Flsm, a W a o W binding Cede A•ceptaaceNoItr o3(g-t3 y u) m a o E►plrrtws Ante M/A�/ �.74 (� � z � � z Fos.> a \ �I ` O M .76592 O U Y ° Si E OF ��� drawing no. �1�9��� W 1 2— 0 8 e��I\\ sheet 9 of 9