Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-18-1639
Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Permit Parcel Number Issue pate: 7/24/2018 25 NE 108 Street 1121360110430 Miami Shores, FL 33161- Block: Lot: Permit No. RF-6-18-1639 Permit Type: Roof Work Classification: Tile Permit Status: APPROVED Expiration: OV20/2019 Applicant Owner Information Address Phone Cell 25 NE 108 Street MIAMI SHORES FL 33161 Contractor(s) Phone Cell Phone CODA ROOFING, INC 305-681-1060 /pe of Work: Re Roof dditional Info: NEW ADDITION TILE (SANTA FE SPANISH lassification: Residential canning: 3 Fees Due Amount CCF $4.80 DBPR Fee $3.75 DCA Fee $2.50 Education Surcharge $1.60 Permit Fee - New Roof $,250.00 Scanning Fee $9.00 Technology Fee $6.40 Total: $278.05 Valuation: $ 7,470.00 Total Sq Feet: 800 Pay Date Pay Type Amt Paid Amt Due Invoice # RF-6-18-67934 07/24/2018 Check #: 19096 $ 278.05 $ 0.00 Available I Inspection Type: Up Lift Report Final Roof Tile In Progress Renailing Affidavit Review Roof In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT certimhat all t foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and z ng. F ror uthorize th ab�ovve med co7n actor to do the work stated. L Li e ✓ LET( —a r) n Julv 24. 2018 Authorized Signature: Owner / Applicant / Contractor / Agent Building Department Copy 1 r 1, BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 / FBC 20 l� Master Permit No. Sub Permit N0 �OOFING ❑ REVISION ❑ EXTENSION [—]RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: _ - City: Miami Shores County: Miami Dade Zip:-::3/9;/ Folio/Parcel#:.1,1 OA3f( Is the Building Historically Designated: Yes NO Occupancy Type: Load OWNER: Name (Fee Simple Titleholder): Address: City Tenant/Lessee Name: Email: Construction Type: Flood Zone: BFE: FFE: Phone#: State: Zip: CONTRACTOR: Company Name: Phone#: ��i � -:O, a Address: 46 77e E .ZO City: r7/olLv� State: �� Zip: .33013 Qualifier Name: 7.1A,1 D 0Z41-,'0 Phone#: 69-1 -106 0 State Certification or Registration #: CCC-z 3z60 1S Certificate of Competency #: DESIGNER: Architect/Engineer: hone#: Address: City: State: Zip: Value of Work forthisPermit: $ _1 9�0 Square/Linear Footage of Work: gC7C7 Type of Work: E Addition ❑ Alteration J ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: �(/QG!/ liWC 1 //0-0 %!l¢ ,e'-SOQJ7/SLi It 5� Specify color of color thru tile: Submittal Fee $ Permit Fee $ "" W CCF $ 17 Scanning Fee $ Radon Fee $ DBPR $ 3 Technology Fee $, Structural Reviews $ Training/Education Fee $ CO/CC $ /-S Notary $ Double Fee $ Bond$--PCI'�-cc,22,1 ci& TOTAL FEE NOW DUE $ ' V (Revised02/24/2014) Bonding Company's Name (if applicable) �t Bonding Company's Address City State Mortgage Lender's Name (if applicable) _ Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: 1 certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Sign OWNER or AGENT The foregoing instrument was acknowledged day of me or who has produced Ke me this , by personally known to as Signatu The foregoing instrument was acknowledged before me this 2'l day of 6&Or�( , 20 1 5 by 0r•1060160 LO--alb . wh s ersonally no to me or who has produced identification and who did taVan oath. identification and who did take an oath. NOTARY PUBLIC: X NOTARY PUBLIC: as Sign: Sign: V Print: Print: V�►V-55k ►-- �.�Ue,Ira Seal: Seal: �A"� Notary Public State of Florida :° VANESSA M RIVERO s My Commission GG 116537 or�oe Expires 06/19/2021 APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) 6/13/2018 Property Search Application - Miami -Dade County v. OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-2136-011-0430 Property Address: Owner Mailing Address PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/2/0 Floors 1 Living Units 1 Actual Area 1,871 Sq.Ft Living Area 1,568 Sq.Ft Adjusted Area 1,720 Sq.Ft Lot Size 9,225 Sq.Ft Year Built 1952 Assessment Information Year 2018 2017 2016 Land Value $230,638 $230,638 $198,007 Building Value $132,681 $133,678 $141,254 XF Value $6,415 $6,497 $0 Market Value $369,734 $370,813 $339,261 Assessed Value $243,467 $238,460 $233,556 Benefits Information Benefit Type 2018 2017 2016 Save Our Homes Cap Assessment Reduction $126,267 $132,353 $105,705 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead 1 Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 36 52 41 PB 52-33 DUNNINGS MIAMI SHORES EXT NO 7 LOT 11 BLK 215 LOT SIZE 75.000 X 123 OR 19734-3157 06 2001 1 Generated On : 6/13/2018 Taxable Value Information 2018 2017 2016 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $193,467 $188,460 $183,556 School Board Exemption Value $25,0001 $25,0001 $25,000 Taxable Value $218,467 $213,460 $208,556 City Exemption Value $50,0001 $50,000 $50,000 Taxable Value $193,467 $188,460 $183,556 Regional Exemption Value $50,0001 $50,0001 $50,000 Taxable Value $193,467 $188,460 $183,556 Sales Information Previous Sale Price OR Book -Page Qualification Description 11/22/2009 $325,000 27125-1758 Qua] by exam of deed 03/01/2006 $520,000 24363-1625 Sales which are qualified 01/01/2005 $385,000 23023-1685 Sales which are qualified ......._.. 06/01/2001 $214,000, 19734-3157 Sales which are qualfed The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, A 33138 Re: Owner's Name: Property Address. _ _ Roofing Permit Number: Dear Building Official: certify that I am not required to retrofit the roof to wall connections of my building because: , 64he just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) x SignatY MAHARAI K. GONZALEZ Print Name MY COMMISSION # GG 044602 EXPIRES: November 2, 2020 - ;1 F o" Bonded Thru Notary Public Underwriters State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this day of �- t Notary Public, Sate of Florida at Lar n�;(- When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 T 003579 Local Business Tax Receipt Miami -Dade County, State of Florida -THIS IS NOT A BILL - DO NOT y. ,.;., 6:118061 �/ BUSINESS NAME/LOCATION RECEIPT NO. EXPIRES CODA ROOFING INC RENEWAL SEPTEMBER 30, 2018 4678 E 10 LN 6381081 Must be displayed at place of business HIALEAH FL 33013 Pursuant to County Code Chapter SA- Art. 9 & 10 OWNER SEC. TYPE OF BUSINESS PAYMENT RECEIVED CODA ROOFING INC 196 SPECIALTY BUILDING CONTRACTOR BY TAX COLLECTOR - C/0 ORLANDO LOZANO; RRfS - • CCC1326045a- _ $45:00 08104/301Z:, Worker(s) i CHECK21-17-074915 This Local Business Tax Receipt only confirms payment of the Local Business Tex, The Receipt is not 8license, permit, or a certification of the holder's quafitications,tc do business. Holder must comply with any governmental or.nongavornmental regulatory lows end requirements which apply to the business. The RECEIPT NO, above must be displayed on all commercial vehicles - Miami -Dade Code Sec Be-276. For more information, visit vvw miamidade goy axcollector KEN LAWSON, SECRETARY RICK SCOTT, GOVERNOR STATE OF FLORIDA DEPARTMENT O CONSTRUCTIONINDUSTRY �f:,ENS1t1G BOAR LILATION i CCC1326045 The ROOFWG CONTRACTOR ; Named hel°w IS ov lion CERTIFIED oflChapter 489 F& Under the P Expiration date: AUG 31, 2018 LOZANO, ORLANDO CQDA ROOFING INC 4678 E 10 LANE D1'3' HIALEAH FL 33 ISSUED; U1 9/2016 piSFLAYi4S REOUIRED BY'LAW yyr(� 1f ,t'�4h aM1i',CF`~ © ,. 13 SEQ # L16082g00f)1674 AC CERTIFICATE OF LIABILITY INSURANCE (MW DATE 05/25/2OD 18 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. MP RTANT: If the certIficeA holder is an ADDITIONAL INSURED, the pollcy(les must have ADDITIONAL INSURED provisions or be endorsed. if SUBROGATION IS WAIVED, subject to the terns and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endomement(s). PRODUCER DELTA INSURANCE UNDERWRITERS, INC, 777 N.W. 72nd AVENUE, SUITE 3133 MIAMI, FLORIDA 33126 LUIS DE LA LLERA PRONE, ; 305-269-1107 No ; 305-269 1108 AIC ADDR68, DELTAINSUND@AOL.COM INSURER(S) AFFORDING COVERAGE NAIC 0 INSURERA: SCOTTSDALE INSURANCE COMPANY 41297 INSURED CODA ROOFING, INC. 4678 EAST 10th LANE HIALEAH, FLORIDA 33013 INSURER B : INSURER C : INSURER D : INSURER E : INSURER F : f\A\2�A/9 me [`CDTIFIt`ATE M!lMFU;R• I(EV151UN NUMI3t11: .. THIS IS TO CERTIFYTHATTHE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMEDABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAYBE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. TYPE OF INSURANCE POLICY NUMBER MMID FUt.19Y UP POLICY UP LBNTS rA COMMERCIAL GENERAL LABILITY CLAIMS -MADE ® OCCUR 7BCS0036494 OS/21/2017 08/21/2018 EACH OCCURRENCE S 1.000.000. PREMISES (Fe oddnYence) $ 100,000. MED EXP (Any one person) S Excluded PERSONAL AADVINJURY $ 1,000,000. GERLA GREGATELIMITAPPLIESPER: Q PRO- LOC POLICY JECT OTHER: GENERAL AGGREGATE S 2,000,000. PRODUCTS-COMPlOPAGG $ 2,000,000. Ded Per Occurrence $ 5,000. AUTOMOBILE LIABILITY AUTO OWNED SCHEDULED AUTOS ONLY AUTOS HIRED NON -OWNED AUTOS ONLY AUTOS ONLY (Ea axi I111 S BODILY INJURY (Per person) $ BODILY INJURY (Per accident) S FDAPPME Per sacWenl S $ UMBRELLA UAB EXCESS LIAB OCCUR CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE S DED RETENTIONS S WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETORIPARTNERIEXECUTIVE Y� OFFICERIMEMBER EXCLUDED? (Minds" In NH) H yp describe under DESCRIPTION OF OPERATIONS below NIA UTK- STATUTE ER E.L.EACH ACCIDENT i E.L. DISEASE - EA EMPLOYEE S E.L. DISEASE -POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101, Addhional Remarks Schedule, may be attached B more space Is requlnd) ROOFING CONTRACTOR LICENSE NUMBER: CCC1326045. MIAMI SHORES VILLAGE! BUILDING DEPARTMENT 10050 NE 2nd AVENUE MIAMI SHORES, FL 33138 PH 305 795 2204 FAX 305 7568972 SHOULD ANY OF THE ABOVE DESCRIBED POUCIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE LUIS DE LA LLERA \1' m 4onn_,mgs ArnRn rORPORAT10N. All rlahts reserved. ACORD 26(2016103) The ACORD name and logo are registered marks of ACORD 44 A� R CERTIFICATE OF LIABILITY INSURANCE DATE (MMIDD/YYYY) 12/27/2017 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Bowen, Miclette & Britt of FL 1020 N. Orlando Avenue Suite #200 CONTACT NAME; Shanae Roberts -- — -- m-.. `PHONE- (/vc.no tsl: 407-647-1616 ac Nc:407-62& 1635 _ ADDRESS: certificates bmbinc:Com INSURER(S)AFFORDING COVERAGE NAIC# Maitland FL 32751 INSURER A: Bridgefield Employers Insurance Co. 10701 _ INSURED CODAROOFIN mm Coda Roofing Inc. 4678 East 10th lane INSURER B : INSURERC Hialeah FL 33013 INSURERD: INSURER E : INSURER F : rnVFRAnFR CERTIFICATE NUMBER: 1R9A795717 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ----- _ ----- m INSR TR ..._.._,...._ TYPE OF INSURANCE AODL SUER' POLICY NUMBER POLICY EFF MMlD POLICY EXP D7YYVY LIMITS COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ CLAIMS -MADE [-] OCCUR 6AMAGETO RENTED PREMISES(Ea occur.ence $ MED EXP (Any one person) Is PERSONAL & ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ PRODUCTS -. COMP/OP AGG POLICY JECT 7 LOC OTHER' $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT _LEa agg_4i l)�, ...... $ ANY AUTO I BODILY INJURY (Per person) $ ,.. _. OWNED ) SCHEDULED AUTOS ONLY AUTOS HIRED NON -OWNED AUTOS ONLY .. AUTOS ONLY BODILY INJURY (Per accident) $ I PROPERTYDAMAGE ! (Par acciUenI ' $ i� UMBRELLA LIAB '': OCCUR EACH OCCURRENCE $ $ _ �. EXCESS LtAS CLAIMS -MADE DED RETENTION $ iAGGREGATE i $ A WORKERS COMPENSATION AND EMPLOYERS' LIABILITY1____!_STATUTE ANYPROPRIETOWPARTNER/EXECUTIVE --1 OFFICER/MEMBER EXCLUDED? (� (Mandatory In NH) N / A 830-43536 111/2018 1/1/2019 PER OTH- _- ER �� E.L. EACH ACCIDENT ... $ 1,000.000 E-L_ DISEASE - EA EMPLOYEE $1,D00.000 E.L. DISEASE - POLICY LIMIT $1.000.0D0 If yes. describe under DESCRIPTION OF OPERATIONS below _T I DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space Is required) The following policy provisions and/or endorsements form part of the policies of insurance represented by this certificate of insurance. The terms contained in the policies and/or endorsements supersede the representations made herein. Electronic copies of the policy provisions and/or endorsements listed below are available by emailing: certificates@bmbinc.com LUCK Village of Miami Shores 10050 NE 2 Avenue Mimia Shores FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENT ,%.fit/ W I`JOD-CU-ID Nt.rV RU I.V Rr VI[AI IWFM. M11 IIviltb ttrbt:1 VUU. ACORD 25 (2016/03) The ACORD name and logo are registered marks of ACORD Proof of Coverage Page 1 of 1 WC Mobile. App TtiC Rome Search Our Data CIAO Home Employer List Page This database was last updated Thursday, June 14, 2018 12:08 AM. Return to Search Page Employer Policy Number Information 1 records found for employer policy number 83043536. Click the links below the Employer Name column for more detailed information. Record Employer Name (Employer Address ... ...... ..... ...... ......_..... .._..... ...--................_............__...__.._..._.......__.... i 1CODA ROOFING INC 4678 E 10TH LN, HIALEAH, FL 33013-2112 1 records found for employer policy number 83043536. Return to Search Page Cov !Exem Elec .......................... ................. -- ................ .... _...... .... Cov Exem https:Happs8.fldfs.com/proofofcoverage/EmployerList.aspx 6/14/2018 Proof of Coverage Page 1 of 1 ANC Mobile _lpp WC home search Our Data CIO IIorne Employer Detail Page This database was last updated Thursday, June 14, 2018 12:08 AM. Carrier Location Information Return to Search Page Employer Information Employer Name Employer Type NAICS Code CODA ROOFING INC (CORPORATION 1238160 Coverage History Governing Class Effective Detailed Coverage Carrier Office Policy Number Wrap Code` Date Information Up 05551 Jan 1 2018 Detailed Coverage BRIDGEFIELD EMPLOYERS 83043536 NO Information INSURANCE 05551 Jan 1 2017 Detailed Coverage BRIDGEFIELD EMPLOYERS 83043536 NO Information INSURANCE 05551 Jan 1 2016 Detailed Coverage BRIDGEFIELD EMPLOYERS 83043536 NO Information INSURANCE 05551 Jan 1 2015 Detailed Coverage BRIDGEFIELD EMPLOYERS 83043536 NO Information INSURANCE 05551 Jan 1 2014 Detailed Coverage BRIDGEFIELD EMPLOYERS 83043536 NO Information INSURANCE 05551 Jan 1 2013 Detailed Coverage BRIDGEFIELD EMPLOYERS 83043536 NO Information INSURANCE 05551 Jan 1 2012 Detailed Coverage BRIDGEFIELD EMPLOYERS 83043536 NO Information INSURANCE 05551 Jan 1 2011 Detailed Coverage BRIDGEFIELD EMPLOYERS 83043536 NO Information INSURANCE 05551 Jan 1 2010 Detailed Coverage BRIDGEFIELD EMPLOYERS 83043536 NO Information INSURANCE 05022 Jan 1 2006 Detailed Coverage INSURANCE COMPANY OF THE WC69203010103 NO Information AMERICAS 05022 Jan 1 2005 Detailed Coverage INSURANCE COMPANY OF THE WC69203010102 NO Information AMERICAS 05645 Jan 1 2004 Detailed Coverage INSURANCE COMPANY OF THE WC69203010102 NO Information AMERICAS 05551 Jan 1 2004 Detailed Coverage INSURANCE COMPANY OF THE WC0301015000129 NO Information AMERICAS 05022 Jun 30 2003 Detailed Coverage INSURANCE COMPANY OF THE WC69203010102 NO Information 1ANIERICAS *Represents the Governing Class Code associated with the Named Insured on the policy, as reported by the Insurance Carrier, and is not validated as correct. Exemption Listings Exemption Holder Name - Click on the name(s) below to view more detailed information CARLOS A LOZANO DIEGO LOZANO ORLANDOLOZANO Owner Election Listings INo Owner Election of Coverage Listings Employer Name History Employer Name Name Type Change Date (CODA ROOFING INC ILegal ICurrent I Return to Search Page https://apps8.fldfs.com/proofofcoverage/EmployerDetail.aspx?EmpID=242564001 6/14/2018 . Proof of Coverage Page 1 of 1 GNC Mobile. App WC biome Search. Oiir Data CFO Home Locations Detail Page This database was last updated Thursday, June 14, 2018 12:08 AA1. Return to Employer Detail Page CODA ROOFING INC Policy Number: 83043536 Effective Cancellation `Total Date Effective at Street Address City State Zip Number of 12:01 A.M. Employees Jan 1 2018 I Current .... i.... .... 4678 E 10TH LN I HIALEAH FL I 3012 I 27 'Represents the total number of employees as reported by the insurance carrier "Carriers were not required to report the total number of employees for policies issued prior to October 1, 2009 Return to Search Page https:Happs8.fldfs.com/proofofcoverage/LocationsDetail.aspx?PolicyID=83043 536&Effec... 6/ 14/2018 y 5 FLORIDA BUILDING CODE 6T" EDITION (2017) A High -Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Master Permit No. Process No. Contractor's Name: CODA ROOFING INC. Job Addres ROOF CATEGORY • • • • . . .... ...... Low Slope Mechanically Fastened Tile Mortal/Adhe6va Bet Tile•.X ....:. Aphaltic Shingles Metal Panel/Shingles Wood Shingles/Sl SAW ;....; Prescriptive BUR-RAS 150 .... ..... ...... .... ..... ROOF TYPE .. .. .... •... • • ...... • • New roof X Repair Maintenance Re -roofing . . . . .. ••Recovering . • • ...... ....: ROOF SYSTEM INFORMATION • • • Low Slope Roof Area (SF) - 0 - Steep Sloped Roof Area (SF) 800 Total (sf) 800 Section B (Roof Plan) Sketch Roof plan: Illustrate all levels and sections,roof drains,scuppers, overflow scuppers and overflow drains,include dimensions and levels, clearly identify dimensions of elevated pressure zones and location of parapet. Cl) Q � 0 C O Lu J J W < Q Z } < m W Cl) U � Q Q J d Z U C Q a o c , 0 0 w ° 2 U < a a z o w < Q J < N M s s t 4 � 1Florida Building Code 61h Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form (D ) Section D (Steep Sloped Roof System) Roof System Manufacture I SANTAFE TILE CORPORATION 15-0915.09 Notice Of Acceptance Numb •.•• Minimum Design Wind Pressures,IfApplicable (From Ras 127 or Calculation): •••��• P1: P2: .. .... -39.1 -68.1 -68.1 ' ...... .. .... 000000 ...... 5/8" PLYWOOD ... .. :0 9 0 . . •••• Deck Type: ...... #30 POUND BASE M/ATT ATM • • • • Roof Slope: Type Underayment: D226,TYPE II • 4 :12 00 • • N/A • Insulation: F Fire Barrier: N/A Ridge Ventilation? N/A Fastener Type & Spacing: 1 %" RS ROOF NAILS @ 6" ON LAP A (2) ROWS @ 12- % STAGGERED ON FIELD FOAM Adhesive Type: Type Cap Sheet: BORAL TILE — SEAL Mean Roof Haight: 13' Roof Covereing: SANTAFE SPANISH "S" CLAY ROOF TILE 3" FACE 24 GA @ 4" OC Type & Size Drip Edge Florida Building Code — Building,6th Edition (2017 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida buiding Code 61h Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculation) For Moment based tile systems, chose either Method 1 or2. Compare the vales for M with the values from M, if the M, values are greater than or equal to the M, values,for each of the roof,then the tileattachment method is acceptable Method 1 "Moment Based Tile Calculations per RAS 127" (P1:- 39.1 xX 0.297 = 11.61) -Mg: 5.69 = Mr1 5.92 Product Approval M,=54 (P2:- 68.1 xX 0.297 = 20.22) -Mg: 5.69 = Mr2 14.53 ProductA*.ppraval M, 79.94 (P3:- 68.1 xX 0.297 = 20.22) -Mg: 5.69 = Mr3 14.53 ProductAW"/al M%70.54 Method 2 "Simplitied Tile Calculations Per Table Below" • • • • • • • Required Moment of Resistance (Mr) From Table Below Product Approval M, • see* 0 0 0 0 * 0 0 Mr required Moment Resistance' ...... Mean Roof Height Roof Slope 15' 20' 25' 30' • • • • • • • • • gQ 2:12 34.4 36.5 38.2 39.7 4 .2 3:12 32.2 34.4 36.0 37.4 • • • 3EC8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 "Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based the systems use Method 3. Compared the values for F with the values for Fr. If the F values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (P1: x L = x w: = - W: x Cos = Fr, Product Approval F' (P2: x L = x w: = _) - W: x Cos 8 = Frz Product Approval F (P3: x L = x w: = - W: x cos 6 = Fri Product Approval F Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 6 Job Site Aerodynamic Multiplier Product Approval Restoring Moment due to Gravity M9 Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance M9 Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 472 FLORIDA BUILDING CODE - BUILDING, 6th EDITION (2017) SNonfy. P R/DA SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524A Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the qvW with the required roofing permit, and to explain to the owner the content of the section. The provisions of SWiD&M4402..... govem the minimum requirements and standards of the industry for roofing system insfta&4. Additioaally the • • following items should be addressed as part of the agreement between the owner ant the eeettactor. "f+he oviner's • • • • • initial in the designated space indicates t t the item has been explained. • • • : • • • .... . ..... 2. ---_Renailing w od decks: When replacing roofing, the existing wflod:roo? deck • have to • • • .. .. be renailed in accordance with the current provisions of Section R4403. (The rppf �Zrk is usu�y. • • •, • concealed prior to removing the existing roof system). • . . . . ...... 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 6. k Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. Owner/Agent's Signature Date F ,vNerry Address Revised on 7/9/2009 LD,07/01/2015; Permit Number ature --7-- Date AMMAM ►1Q� MIAMI-DADE COUNTY IR) PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) H,ivw.miamidade.eov/economy Santafe Tile Corporation 8825 NW 95`' Street Medley, FL 33178 SCOPE: •••• •••••• This NOA is being issued under the applicable rules and regulations governing the use of con'sfruciion mafffla%. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Prodn;*control •bec tion to • be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdic jipn (AHJ). ; • • • •; ...... .... . ..... This NOA shall not be valid after the expiration date stated below. The Miami -Dade County.V;g4i&ct ContrgLygction..:..• (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve th-OrigM to haN4�his product or material tested for quality assurance purposes. If this product or material fails to I tl foom in the aocepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately rev;ke, mjodjD , or • • ••+• suspend the use of such product or material within their jurisdiction. RER reserves the rightto r.&.oke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or materiiaf fails to ' meet the requirements of the applicable building code. • 0 This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Santafe Spanish `S' Clay Roof�Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 12-0210.01 and consists of pages 1 through 5. The submitted documentation was reviewed by Gaspar J Rodriguez. 40- NOA No.: 15-0915.09 Expiration Date: 02/01/21 Approval Date: 01/21/16 Page 1 of 5 ROOFING ASSEMBLY APPROVAL Category' Roofing Sub -Category: Roofing Tiles Material: Clay Deck Tyne: Wood 1. SCOPE This approves a roofing system using Santa Fe "Santafe `S" Clay Roof Tile, as manufactured by Ladrillera Santafe S.A. in Bogota, Colombia and distributed by Santafe Tile Corporation as described in SectWIVthis Notice of Acceptance. For locations where the pressure requirements, as determined by "icable t"Iding " Code, do not exceed the design pressure values obtained by calculations in compliance fith T�AS I.-*fxA#ig the... • values listed in section 4 herein. The attachment calculations shall be done as a mome.I.Wid systems • ••a• • • • • 2. PRODUCT DESCRIPTION 0000. • • • • • Manufactured by Test Pr;Xz: ••.• •••••• Applicant Dimensions Specifications Desot on • • 0 Santafe `S' Clay Roof L = 18" TAS 112 One piece high profile clay ro 0ftile ec�ipped with:'•••. `Tile W = I l.l" Type I two nail holes. For nail-o%poi:ar set jad gdhesiv;••••; Thickness = 0.39" Grade 1 set applications. '..'.' Trim Pieces 1= varies TAS 112 Accessory trim, clay roof pieces for use at hips, w = varies rakes, ridges and valley terminations. Manufactured varying thickness for each tile profile. 2.1 MANUFACTURING LOCATION 1. Bogota, Colombia 2.2 SUBMITTED EVIDENCE Test Agency Test Identifier Test Name/Report Date The Center for Applied Engineering, Inc. 94-156-8 TAS 101 Aug. 1994 94-156-9 TAS 102 The Center for Applied Engineering, Inc. 25-7205-1 TAS 101 March 1995 The Center for Applied Engineering, Inc. Project: 07-07-00-91 TAS 100 Sept. 1994 (307023) Redland Technologies 7161-03 TAS 108 Dec. 1991 Appendix II (Nail -On) Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS l 02(A) Redland Technologies P 0402 Withdrawal Resistance Sept. 1993 Testing of Screw vs smooth shank nails Redland Technologies P 0647-01 TAS 108 Aug. 1994 (Mortar Set) NOA No.: 15-0915.09 MIAMFDADE COUNTY Expiration Date: 02/01/21 Approval Date: 01/21/16 Page 2 of 5 2.2 SUBMITTED EVIDENCE Test Agency Test Identifier Test Name/Report Date Redland Technologies P 063 1 -01 PA 108 July. 1994 (Mortar Set) Celotex Corporation Testing Services 520305-01 thru 05 PA 102 June 1999 IBA Consultants, Inc. 2353-4 Restoring Moment Aug. 1999 PRI Asphalt Technologies, Inc. SFTC-003-02-01 TAS 101 12/06/02 IBA Consultants, Inc. 2353-70 TAS 101 09/22/03 IBA Consultants, Inc. 2353-71 TAS 101 09/22/03 IBA Consultants, Inc. 2353-93 ASTM C 1167 07/18/05 American Test Lab of South Florida RT0624.01-15 ASTM C1167-03 07/01/15 . . .... ...... 3. LIMITATIONS .... .' ...... .. . ...... 3.1 Fire classification is not part of this acceptance. • 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be perforuvd in arcordance will TAS 106. ••••• • 0 0 0 • . ••••• 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratoty:60gerform gpw*rly test • • in accordance with TAS 112, appendix W. Such testing shall be submitted W t118 Miami-fllde Count••;• Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications S4aiv&;Ms liste'd*•• section 4.1 herein. ' ; .. . ;' • • • 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof sloes vAlAs stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater. 4. INSTALLATION 4.1 Santafe 'S' and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations NOA No.: 15-0915.09 Expiration Date: 02/01/21 Approval Date: 01/21/16 Page 3 of 5 Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Santafe 'S' 6.7 1.5 0.958 Table 2: Aerodynamic Multipliers— %(ft3) Tile Profile X (ft3) Batten Application X (ft3) Direct Deck Santafe 'S' 0.274 '0.297 , Table 3: Restoring Moments due to Gravity - M9 (ft-Ibf) Tile Profile 2":12" 3":12" 4":12" 1 5":12" 6":12" 7":12" or rester Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens C2irect •Deck 15$erlv Direct Deck Santafe 'S' 5.93 5.90 5.85 5.82 5.73 5:69 , 5.56 5.53 5.32 .29 .08 • 5.00 Table 4: Attachment Resistance Expressed as a Moment - Mr N-115 '• % for Nail -On Systems •••••• Tile Profile Fastener Type Direct Deck Epftens • • Santafe 'S' 2-10d Ring Shank Nails 21.8 09 9 • • • N/A • • One #8 Screw .0 • 29.16' 2 N/A Two #8 Screws 38.28' ...4.A One #8 Screw w/ Clip 57.311,2 Two #8 Screws w/ Clip 57.60' 1. Approved screws as noted 'Product manufactured by others'. 2. When using one screw it must be installed in the inside hole located nearest to the hump of the tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Santafe 'S' Tile Bond 38.93 Polyfoam Polypro AH 160TM 28 54 2 See manufactures component approval for installation requirements. f 3 Flexible Product, Inc. Average weight per patty 10.4 grams. 4 Polyfoam Product, Inc. Average weight per patty 9.4 grams. Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Santafe 'S' Polyfoam Polypro AH 160"m 63.85 Polyfoam Polypro AH 1601 61.96 5 Paddy placement of 63 grams of Polypro AH 160Tm. 6 Paddy placement of 24 grams of Polypro, AH 160Tm. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar or Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Santafe 'S' Mortar Set 23.6 NOA No.: 15-091.5.09 Expiration Date: 02/01/21 Approval Date: 01/21/16 Page 4 of 5 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below, or following statement: "Miami -Dade County Product Control Approved". 6. SANTA FE TM MADE IN COLOMBIA LABEL FOR SANTA FE SPANISH "S" CLAY ROOF TILE BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code irl jvogrto properly evaluate the installation of this system. 6.0 : .... ...... .. PROFILE DRAWING When using tWe:screw:• use this hole. " "" "SANTAFE S" CLAY ROOF TILE END OF THIS ACCEPTANCE NOA No.: 15-0915.09 Expiration Date: 02/01/21 Approval Date: 01/21/16 Page 5 of 5 MIAMI-DADE COUNTY MIAMIDAME PRODUCT CONTROL SECTION ' 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.Eov/economy ICP Adhesives and Sealants, Inc. 12505 NW 44' Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Cant Q1 Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the rigltt to have this product . • • • or material tested for quality assurance purposes. If this product or material fails to perform it the acceptgd"a4ner, the • manufacturer will incur the expense of such testing and the AHJ may immediately revoke, M64", or sugrend'the uSe • • • • of such product or material within their jurisdiction. RER reserves the right to revoke Ml*s' acceptan8e, if it h...: determined by Miami -Dade County Product Control Section that this product or material fail o To feet th*e•regxiremei � s • • • of the applicable building code. • • ...... .... ..... This product is approved as described herein, and has been designed to comply with df Florida Btiihtling Code • • ; - including the High Velocity Hurricane Zone of the Florida Building Code. : ' . • . . . . ...... . . . DESCRIPTION: ICP Adhesives Polyset®AH-160 • • • • • • • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. or W j f NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof file adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Specifications ICP Adhesives Polyset'AH-160 ICP Adhesives Foam Dispenser RTF1000 ICP Adhesives ProPacV 30 & 100 N/A TAS 101 Product Description • •' • . . .... ...... Two component polywobane fdaa adhesiue...:. • . • . • • • • N/A Dispensing Equipment • • • • • N/A Dispensing Equipment • • • • • Ve:% PRODUCTS MANUFACTURED BY OTHERS: ••.• •••• . 0 0 0 : • • • • . . • Any Miaini-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Property Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.6 lbs./ft.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm /Inch +0.07% Volume Change @ -400 F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. , •••••• ... . •.••• NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier 494-060 257818-IPA 25-7438-3 25-7438-4 25-7438-7 25-7492 NB-5 89-631 9637-92 01-6743-011 01-6739-062b[l] 7050.02.96-1 P36700.04.12 P39740.02.12 528454-2-1 528454-9-1 528454-10-1 520109-1 520109-2 520109-3 520109-6 520109-7 520191-1 520109-2-1 Test Name/Report TAS 101 TAS 101 SSTD 11-93 SSTD 11-93 SSTD 11-93 ASTM D 1623 ASTM E 108 ASTM E 108 • • ASTM E 84 • • • TAS 114 ���•�� ASTMD 1623 •�•••• TAS 101 TAS 123 .00000 TAS 101 . . TAS 101 TAS 101 Date 04/08/94 12/16/96 10/25/95 11 /02/95 12/12/95 02/01/94 04/30/93 •.•• 1 r9� 01101V 03/14/96 0U-Wh 02/?,1 fn •..• 19/23/98 12728/98 03/02/99 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset' AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values With the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined 'in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof file assembly NOA. 3. ICP Adhesives Polyset` AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. *so* 5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is r4luiVdbefore'app1ication.... of any adhesive. The mix ratio between the "A" component and the "B" component shall Ue laintairieVetween '. 000... . 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenserft'FF� 000 or ICP . � • .• Adhesives ProPack® 30 & 100 dispensing equipment only. 0000 • •; • • 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 060000 0 • ; 0 000000 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minut*';MgICP Adhesives •, Polyset° AH-160 has been dispensed. """ 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accorWnc! with dia . :"": 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. 0 •. •. ` QMIAM1-DADE COUNTY NOA No.: 17-0322.03 Expiration Date:05/10/22 -0322.03 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles 41 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile 42 12-14 sq. inches 30 High Profile 42 17-19 sq. inches 30 Flat; Low; High Profiles 43 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap .... Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal � � • If grams Z; bead edge) 20-25 sq. inches each oeseoe bead ••... Two Piece Barrel (Pan Tile) I Two Piece 65-70 sq. inches '...34 gramtj liM pan ,. ...... .... LABELING: ..:.. . . . . ...... All approved products listed herein shall be labeled and shall bear the imprint or identifiable markian of the""' . manufacturer's name or logo and following statement: "Miami -Dade County Product Control t�tpprorved" or 4he�Iiami�"": Dade County Product Control Seal as shown below. • • • BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MIAMI•DADE COUNTY NOA No.: 17-0322.03 • � Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # I Nall plastic cwowd paddy IB•r amhTik) eta r•gaa•dl,� ,..-�>,_. ,� 7, 1 � Bak" •phone h' Eao tlawra— .4 Nall tbrough plasik cement iwlten required; zln.adda SEatterss •l+tivnal '`•-' P+d4Y(A n*RdlTiWlI E m C"Ure Fascia NMM thre"O p1or4k . - (wAerte•quNedl r P• *rll4 hTaal `l Sattens i lye !e � tCln,K �, Ea�c•vru �� F weeplroic +� ,r, i7ripadpa Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 min) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm') — 23 (148.4 cm') square inch adhesive contact With the underside of the tile. • • •••• •••••• Medium Profile / Double PM me • • • • • • • � 000000 1. Starting at the eave course, anhJy a mu imOv 2" ' (50.8 mm) x 10" (25, 0 � 1�' (25.4 mm) foam * a 000 paddy onto the under] ayVei Asitio>i j g s showna a a •. • under the pan portion of l;49e closest to the a • overlock of the tile being sef.: • • • •: • 2. Continue in same manner Insure apppKiimitely 1'�1' ... : (109.7 cm') — 23 (148.4 cm2) square utdh adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 KaUOwmg{tplruti<t.ment Prd4YfB n�PthTdcl dwh-requirad) i y tlerddrlrymant j�� ° �`^� = rt' �,, llattaas optional o 1011L Fascia 2 J j Law tloeurt hail through 01"ticcemein twhen mq uiredl f�t�addy (iGcnrxkTllta i.drU.�nne f k 71 Battens optional law Sauruu f F#tom Flat/Low Profile Tile Starting at the eave course, apply a minimum 2" (50.8 min) x 10" (254 min) x 1" (25.4 min) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm') — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x T' (177.8 min) x 1" (25.4 min) foam padd�,*oiito the . . ...... underlayment positioned as;49Q ,under tTie.* •. strengthening rib closest to tja> gNglock aZ Oft Ole • ...... being set. 3. Continue in same manner. Insure•approximately 10" (64.5 cm2) - 12(77.4 cm2) sqh:fe finch adh¢iee • • • • contact with the underside drill ile. "" • • • • • • . . . . ...... Medium Profile / Double Pan Tile • • • • • • 1. Startuig at the eave course, apply a minimum 2" (50.8 min) x 10" (254 min) x 1" (25.4 min) foam paddy onto the underlayment positioned as shown under the pan portion of the file closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm') — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x T' (177.8 min) x 1" (25.4 min) foam paddy onto the underlayment positioned as shown under the pan portion of the file closest to the overlock of the file being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm 2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) Nat through W slk oc P.tlEy 17}.rra+h?il.} (when F"Uit") uodarlaym rl gamns notional EMM Co ,r -Fascia w"F6 011- loin, 2 Ina .. 6�ptdpe F High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 min) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. leisure approximately 17 (109.7 cm') — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2' t'e,�mm) x T' (177.8 mm) x 1" (25.4 nim4 Team paddy bnto the •';' underlayment positioned as s iowne undeeatiie.pan ...... . . ...... portion of the tile closest to YU@ py;rlock oft e .the being set. • • • • • • • . ....•. 00 3. Continue in same manner. I>nexr&approximatelF 17" ..:..' (109.7 cm2) - 19 (122.6 cm�osgttare inch ackesive • • • • • • contact with the underside (rdt'Qle. •, . . . . ...... NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 mail through plastic cement Paddy (between ties) (when required] mattensoptional a Paddy (under tile) ngle paddy antoped t-'r I pad 41 41� ,�?' glepaddy an rod yment +� 2 x ahL t0in.1 ?' Fascia Rat/Low Profile Tile Hal) through plastic cement Single paddy under tile (when required) lop"MalSingle Paddy (between tiles) Battens Paddy(under tile] , pad ., enmport 4x4in.` hhg'ry undeda�yt i 4 in. 10h. �` 2In. � Fame Closure Ewe Course fascia Medium Profile Tile 1. On the cave course only, apply a minimum 2" (50.8 mm) x 10" (254 nun) x V (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat file or wider the pan portion of the tile for low or high profile tile closest to the Overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the cave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in2 (109.7-148.4 cm2) of adhesive contact with the underside of 411a file . . .... ...... 2. Apply a 4" (101.6 mm) )M ;141.6 mntrx P' (25.4.. • • • mm) foam paddy onto the micferlayment just below....: the second course line pos 49ged foagi pAdy • • under the strengthening 4b fp= Ilat tile, gr.VVder tbe.; . . • pan portion of the rile, cles8sub the u &4lock for. •... the second course file to beineialled. Insure approximately 8-9 in2 (5i.6-58:1 cm23 of adhesive • •... ..... contact with the underside of the rile. • ; • • • .. . .. . . . . .. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Nail through plastic Single paddy under the (when required) Paddy ibetween tiles) Battens Paddy {under tilel optional 2X4in. ti 3 tDp tie Eire [orrcse �' uia weepnde Pave closure toin 2 in. Dripedge High ProflleTlle 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4'' (19 mm) paddy on top of the cave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm') - 9 (58.1 cm2) square inch adhesive contact with the underside of jljg file at the head of the tile. Contume in same %Mer. • • • • • • ...... .. . ...... • •••• • ••••• ...•.• .... •..•. .. .. .... ..••.. • . • . ...•.. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 1) piece enough adhesive to achieve 65 to 70: In contact with the pan tile. 2)Tom covers upside down. Place adhesive in to 1 In. from outside edge of cover tile Then install the tile. Ensure 20 to� 25 scl. in. contact area.. IUnderlayme�nt Eaveciosure (motar shown) Fascia Board ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Steep pinch applications (when required) Remove top portion of the save course cover tile. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile APPROVED Two Piece Barrel (Cap and Pan) Tile 1. Starting at the cave course; apply a minimum 2'' (50.8 nun) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support cave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing tv"pan courses up toward the r dg e. 4 nsure • ....' ...... approximately 65 (419.4•em2}— 70 (y4S 4 m2) • square inch adhesive cdif "f dvith theriinderside • • • • • • of the pan tile. """ ' ' • sees eeeee 3. Turn covers upside do"jeapsing le undersid� � • •. of the tile. Apply a mintijy?lyy'1" (25ag�m) x 10, • • • • • • (254 mm) bead of adhasi,wa directly on the inner • • edge of each side of the coves tile. Leave. e a e a : a approximately 3/4" (19 mnjn)4o 1" from the outside edge of the rile, inVW4 ffree of• • foam to allow for expansion. • a e Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 MIAMI- MIAM1-DADE COUNTY � PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.t!ov/economv Boral Roofing LLC. 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction matejigajs. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Prvdu ct•Control Section to ba.... used in Miami Dade County and other areas where allowed by the Authority Having Jurisdictitnl (RHJ). • • • • 009s00 .. . Soso% This NOA shall not be valid after the expiration date stated below. The Miami -Dade CountyoPmdtitt Control -Section • • (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve theii itht to hatg rho. • product or material tested for quality assurance purposes. If this product or material fails to pertorm in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately Y;yeke, modify, or •' • suspend the use of such product or material within their jurisdiction. RER reserves the righttprpypke this ar�ceptance, • if it is determined by Mianu-Dade County Product Control Section that this product or matelaal tails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Bliilding�Eco ft. • • • including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: BORAL TileSeal LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renewes NOA#13-1113.05 and consists of pages 1 through 4. The submitted documentation was reviewed by Freddy Senzino NOA No.: 17-0530.10 Expiration Date: 07/31/18 Approval Date: 07/27/17 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS PRODUCTS DESCRIPTION: Product BORAL TileSeal Dimensions 36" x 36' rolls 36" x 72' rolls MANUFACTURING LOCATION: 1. Brentwood, NH EVIDENCE SUBMITTED: Test Agency Underwriters Laboratories, Inc. IRT-Arcon, Inc. PRI Asphalt Technologies, Inc. PRI Asphalt Technologies, Inc. PRI Construction Materials Technologies, LLC. Test Specification TAS 103 ASTM D 1970 Test Identifier R14610 02-012 NEI-006-02-01 Product Description SBS self -adhering asphalt sheet material with a white glass re -enforced polyester su rfneingifabric; for use as an underlayn-tnt id sloped fouf• • • • • • • assemblies. • • .":'. '. ..:.... .. . ...... .... . ..... ...... .... ..... .. .. .... ...... . . . . Test Name/Report .... Date ...... Follow up Service " .' 10.39;8/02 • • TAS 103 02/28/02 TAS 103 04/01 /02 NEI-008-02-01 TAS 114 (H) 07/30/02 NEI-045-02-01 ASTM D 4798 & ASTM G 155 08/08/07 NEI-053-02-01 ASTM D 4798 & ASTM G 155 05/01/08 NEI-076-02-01 TAS 103 / ASTM D4798 02/14/11 NEI-034-02-02 ASTM D 1970 01/29/13 NOA No.: 17-0530.10 MIAMMADECOUtM Expiration Date: 07/31/18 • Approval Date: 07/27/17 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated Deck Description: 15/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Membrane: One or more plies of BORAL TileSeal Underlayment with a minimuriVY �qd lap and minimum• • • • • 6" end lap. Place the first course of membrane parallel to the eave, rolli$A the membl'&:e to •, obtain maximum contact. Remove the release membrane as the mei 4l'ia is applied.* Vertical + • • • • • 000000 strapping of the roof with BORAL TileSeal Underlayment is acceptabrll end l,ps and laps+...� without black selvage area shall be sealed under lap using an SBS modiffi, 4fhastic;000000 *see • • • • • • •• • • Note: When used in Tile roof systems BORAL TileSeal Under] ayment5Imi be bae)E;wiled to ...... deck with approved annular ring shank nails and tin caps at a maximuV6*. b c. at the side laps. • • ...... No nails or tin caps shall be exposed. ...... Surfacing: Approved for Approved Adhesive Set Roof Tile Systems, Mechanically Fastened RQQfNile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies. NOA No.: 17-0530.10 Expiration Date: 07/31/18 Approval Date: 07/27/17 Page 3 of 4 ti LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tilgs are le; jj j directly • 0 6 • to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitZh egfeater th„ 4:12". '66 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed aplhA?v:Ltbf this ptod;ct wi*r••:• 000000 specific prepared roofing products. ...... 8. Tiles shall be stored on battens on roof pitches greater than 6:12". •.... • ; • • • • 9. BORAL TileSeal underlayment may be used with any approved roof covering Nolitt•ef Acceptaxaa listiv:00* BORAL TileSeal underlayment as a component part of an assembly in the Notice of•ACCeptancC! *?f BORAX • •: • TileSeal underlayment is not listed, a request may be made to the Authority Having:1104iction (AW) or the •. Miami -Dade County Product Control Department for approval provided that appropriate docL-Aaatation 33'`* provided to detail compatibility of the products, wind uplift resistance, and fire testing reW? ; • • • • 10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking par►e'lc.' Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment shall be applied over the underlayment, and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below APPROVED END OF THIS ACCEPTANCE NOA No.: 17-0530.10 Expiration Date: 07/31/18 Approval Date: 07/27/17 Page 4 of 4