RF-18-46`yµortes t��
Miami Shores Village
10050 N.E. 2nd Avenue NE
Miami Shores, FL 33138-0000
Phone: (305)795-2204
FCORIDp'
Permit
Issue Date:1/19/2018
Permit NO. RF-1-18-46
Permit Type: Roof
Work Classification: Tile
Permit Status: APPROVED
Expiration: 07/18/2018
Project Address Parcel Number Applicant
420 NE 91 Street 1132060190070
PROPERTY HOUNDS LLC
Miami Shores, FL 33138- Block: Lot:
Owner
PROPERTY HOUNDS LLC 420 NE 91 Street (954)520-2268
MIAMI SHORES FL 33138-
7021 NW 67 Court
PARKLAND FL 33067-
Contractor(s) Phone Cell Phone
XCLUSIVE ROOFING FLORIDA LLC (954)309-4525 (786)290-1908
Type of Work: Re Roof
Additional Info: NEW ROOF - GREY TILE
Classification: Residential
Scanning: 3
Fees Due
Amount
CCF
$7.20
DBPR Fee
$4.88
DCA Fee
$3.25
Education Surcharge
$2.40
Permit Fee - New Roof
$325.00
Scanning Fee
$9.00
Technology Fee
$9.60
Total:
$361.33
Cell
Valuation: $ 12,000.00
Total Sq Feet: 3995
Pav Date Pav TVDe Amt Paid Amt Due I
Invoice # RF-1-18-66067
01/08/2018 Check* 1231
01/19/2018 Check* 1089
$ 50.00 $ 311.33
$ 311.33 $ 0.00
Avauame
Inspection Type:
Up Lift Report
Tin Cap
Final Roof
Tile In Progress
Renailing Affidavit
Review Roof
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and3o1 g' FuthermorI%hori the above -named contractor to do the work stated.
GJanuary 19, 2018
Authorized Signature: Owner / Applicant / Contractor / Agent Date
Building Department Copy
January 19, 2018
1
A
Miami Shores Village RFCF'VtD
1
Building Department J'`A'V08�v
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
FBC 2Q/�-
BUILDING Master Permit No. RC -U-1-7-15CO
PERMIT APPLICATION Sub Permit No. J�a -- 4W
BUILDING ❑ ELECTRIC FE-1 ROOFING REVISION ❑ EXTENSION RENEWAL
M PLUMBING ❑ MECHANICAL ❑ PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR
DRAWINGS
JOB ADDRESS: q ST
City: Miami Shores County: Miami Dade Zip: a
Folio/Parcel#: I I "320(0 fUl� b(�1 d Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): 1'r tDQCAj* 14 ndC Ll C Phone#:
Address fl Q
City: Pa ci and State: L Zip: 33 A.(-P= 7
Tenant/Lessee Name:
Email:
ne#:
CONTRACTOR: Company Name: XCLUSIVE ROOFING FLORIDA Phone#: 9543094525
Address: 1361 NW 198 ST
City: MIAMI GARDENS State: FL
Qualifier Name: RODERICK SPENCER
State Certification or Registration #: CCC1330992
DESIGNER: Architect/Engineer:
33169
ne#: 7862901908
Certificate of Competency #:
Phone#:
Address: City: State: Zip:
Value of Work for this Permit: $ ,$ ( Square/Linear Footage of Work': 61
Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ lace Re air Re p / p ❑Demolition
Description of Work: NEW ROOF
Spec ffcolor of color thru tiler r G !�.A
Submittal Fee $ �5(.1 Permit Fee $ 325 • CCF $ CO/CC $
Scanning Fee $ Radon Fee $ 3 • 21& DBPR $ Notary $
Technology Fee $
Structural Reviews $
Training/Education Fee $
Double Fee $
Bond $"-C 1 — ( sq
TOTAL FEE NOW DUE $ �34 I • 33
(Revised02/24/2014)
. N
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
V2Signature Signature
OWNER or AGENT CO CTOR
The foregoing instrument was acknowledged before me this
Z i day of O tCemhP f . 20 1-I by
� 1641=1 EA r� wh�ayme or who has produced
identification and who did take an oath.
NOT
Sign
Prin-
Seal
The foregoing instrument was acknowledged before me this
21 day of DECEMBER 20 17 by
RJ SPENCER who is personally known to
me or who has produced NA as
identification and who did take an oath.
*#***«*•s**sr****t***r**«*rs sss*ys�s*s**rsssssrr***«*esrssssssss*sssss*see*s�ss�rs*sss*sss***ess*rrs::*«rs***
APPROVED BY u Plans Examiner Zoning
Structural Review Clerk
(Revised02/24/2014)
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
CONTRACTORS' REGISTRATION
IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR:
A. I/ C1PY OF QUALIFIER'S STATE LICENCES
B. �' COPY OF LOCAL BUSINESS TAX RECEIPT
C. sV/-1� OPY OF LIABILITY INSURANCE*
D. COPY OF WORKERS COMPENSATION INSURANCE*
(Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit)
IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY:
A. COPY OF CERTIFICATE OF COMPETENCY OF QUALIFIER
B. COPY OF LOCAL BUSINESS TAX RECEIPT
C. COPY OF STATE REGISTERED CONTRACTOR LICENSE OR MIAMI DADE COUNTY MUNICIPAL
CONTRACTOR'S TAX RECEIPT.
D. COPY OF LIABILITY INSURACE*
E. COPY OF WORKERS COMPENSATION INSURANCE*
(Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit)
*YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE AS FOLLOW:
Certificate Holder:
MIAMI SHORES VILLAGE BLDG DEPT
10050 NE 2ND AVE
MIAMI SHORES, FL 33138
Certificate must specify the description of operations or contractor license number.
BUSINESS NAME: %�us�y� c �► l cot tic
BUSINESS ADDRESS: LCl 'g—'Sr CITY/ /cC►% 1 STATES ZIP33I
BUSINESS PHONE: tie
CELL PHONE (�
QUALIFIER'S LIC NUMBER:
Local . Busi ness Tax Iecei pt
Miami -Dade County, State of Florida
THIS IS NOT A BILL - DO NOT PAY
7232140
BUSINESS NAM E/LOCATION
XCLUSIVE ROOFING FLORIDA
LLC
1361 NW 198 ST
MIAMI, FL 33169
OWNER
XCLUSIVE ROOFING FLORIDA LLC
C/O TONYA L BOWLEG MGR
Worker(s)
RECEIPT NO. EXPIRES
NEW BUSINESS SEPTEMBER 30, 2018
7517515 Must be displayed at place of business
Pursuant to County Code
Chapter 8A - Art. 9 8 10
SEC. TYPE OF BUSINESS pAYM ENT RECEIVED
196 SPECIALTY BUILDING BY TAX COLLECTOR
CONTRACTOR 45.00 69/25/2017
CCC1330992 0224-17-004876
This local Business Tax Receipt only con"nnapaymant of the local Business Tax. The Receipt is not a license,
permit or a ceffl "cation of the holders quall"cations, to do business. odder must comply with any governmental
or nongovernmental regulatory laws and requiremertiswhich apply to the business
The F EMP'TNQ above must be displayed on all commercial vehides- Miami -Dade Code Sec 8a-2m
[) For more Information,visitwww.mlamidade.aovffwmdlector
Congratulations! With this license you become one of the nearly
one million Floridians licensed by the Department of Business and
Professional Regulation, Our professionals and businesses range
from architects to yacht brokers, from boxers to barbeque
restaurants, and they keep Florida's economy strong.
Every day we work to improve the way we do business in order
to sere you better. For information about our services, please
log onto www.myfloridalicense.com. There you can find more
information about our divisions and the regulations that impact
you, subscribe to department newsletters and learn more about
the Department's initiatives.
Our mission at the Department is: License Efficiently, Regulate
Fairly. We constantly strive to serve you better so that you can
serve your customers. Thank you for doing business in Florida,
and congratulations on your new license!
RICK SCOTT, GOVERNOR
CCC1330992
STATE OF FLORIDA
t DEPARTMENT OF BUSINESS AND
vµ" PROFESSIONAL REGULATION
CCC1330992 ISSUED: 06/13/2016
CERTIFIED ROOFING CONTRACTOR
SPENCER, RODERICK J
XCLUSIVE ROOFING FLORIDA LLC
IS CERTIFIED under the provisions of Ch.489 FS.
Exptretian date : AUG 31, 2018 L1606130303225
DETACH HERE
KEN LMNSON, SECRETARY
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
CONSTRUCTION INDUSTRY LICENSING ROARn
I nc Iwv(-IIVV %JVIV I ISPiV 1 Vr�
Named below IS CERTIFIED
Under the provisions of Chapter 489 FS.
Expiration date: AUG 31,.2018
SPENCER, RODERICK J
XCLUSIVE ROOFING FLORIDA LLC
1811 SW 91 AVE
MIRAMAR FL 33025
ACORN CERTIFICATE OF LIABILITY INSURANCE
DATE(MM/DDNYYY)
12/18/2017
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED
REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to
the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the
certificate holder in lieu of such endorsement(s).
PRODUCER
CONTANAME: CT Certfificate Department
Enterprise Insurance Group LLC
12320 Racetrack Road
Sunrise FL 33313
License #1_059361
PHONE . (800)329-2140 pp%C No):
A DRESS:
INSURE S AFFORDING COVERAGE
NAICM
INSURER A: Lloyd's of London
INSURED
INSURER B : Technology Insurance CO.
INSURERC:
Xclusive Roofing Florida LLC
1361 NW 198th Street
Miami Gardens FL 33169
INSURERD:
INSURERE:
INSURER F :
COVERAGES CERTIFICATE NUMBER: REVISION NUMRFR-
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
INSR
LTR
TYPE OF INSURANCE
D L
SUBR
POLICY NUMBER
MWODPOLICY EFF
MMMIDPOLIDEXP
LIMITS
A
COMMERCIAL GENERAL LIABILITY
CLAIMS -MADE ® OCCUR
DCCSGLOO699-00
03/16/2017
03/16/2018
EACH OCCURRENCE
$ 1,000,000
DAMAGE ORENTED
PREMES Ea occurrence
S 50,000
MED EXP (Any one person)
$ 5,000
PERSONAL & ADV INJURY
$ 1,000,000
GEN'L AGGREGATE LIMIT APPLIES PER:
POLICY E JECOT- LOC
OTHER:
GENERAL AGGREGATE
$ 2,000,000
PRODUCTS - COMP/OP AGG
$ 2,000,000
$
AUTOMOBILE
LIABILITY
ANY AUTO
ALL OWNED SCHEDULED
AUTOS AUTOS
NON -OWNED
HIRED AUTOS AUTOS
+
COMBINED SINGLE LIMIT
Ea accident
$
BODILY INJURY (Per person)
$
BODILY INJURY Per accident
( )
$
PROPERTY DAMAGE
Peraccident
$
$
UMBRELLA LIAR
EXCESS LIAB
OCCUR
CLAIMS -MADE
EACH OCCURRENCE
S
_ _
AGGREGATE
$
DED RETENTION S
$
B
WORKERS COMPENSATION
AND EMPLOYERS' LIABILITY y / N
ANY PROPRIETOR/PARTNER/EXECUTIVE
OFFICERIMEMBER EXCLUDED? ®
(Mandatory in NH)
If yes, describe under
DESCRIPTION OF OPERATIONS below
N / A
TWC351331
03/16/2017
03/16/2018
PER OTH-
STATUTE ER
E.L. EACH ACCIDENT
$ 1,000,000
E.L. DISEASE - EA EMPLOYEd
$ 1,000,000
E.L. DISEASE - POLICY LIMIT 1
$ 1,000,000
DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required)
Roofing Contractor License CCC#1330992
Commercial & Residential
GANGtLLA I IUN
Village of Miami Shores SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
Building Department THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN
10050 NE 2nd Avenue ACCORDANCE WITH THE POLICY PROVISIONS.
Miami Shores FL 33138
A 6�ENTATIVE
Cc�e �e!/ejaee
n enQo anew w�non nnnnnnwTrnu wu _.
ACORD 25 (2014/01) The ACORD name and logo are registered marks of ACORD
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition (2014)
r
High -Velocity Hurricane Zone Uniform Permit Application Form.
1
1
1
�ecs�on A (General Information)
Master Permit No. �! "�
1
Q • •
Process (✓�.
1
Noy . .'
000 0.a
Contractor's Name ... • •001
Job Address �/ •
ROOF CATEGORY "; "; • • • •
• • • .r
❑ ❑ Low Slope • • • • ••
Mechanically Fastened Tile Mortani4dheslve Set Tiles
.....,.
❑ Asphaltic Shingles ❑ Metal Panel/Shin les •
9 O WoodShingf'es/Sha%Qs.:.
'
❑ Prescriptive BUR-RAS 150 . .
'
ROOF TYPE •
:....r
G2)
❑ Repair ❑ Maintenance ❑ Reroofing1 ❑ Recovering
ROOF SYSTEM INFORMATION
1
Low Slope Roof Area (SF) Steep Sloped Roof AREA (SSF) Total (SF)399S
1
1
Section B (Roof Plan)
i
Sketch Roof Plan: lilustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen-
sions of sections and levels, clearly identify dimensions
of elevated pressure zones and location of parapets.
1
1
1
1
1
�
1
1
_
f _
1
AN 0 1
i
1
1
Q 1 71
s
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014)
1.37
Copyright to, or licfurther
by, ICC (ALL RIGHTS RESERVED); accessed by Eliczer Palacio on Jun $. 2015 10:32:12 AM pursuant to
Agreement. No reproductions authorized. License
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section D (Steep Sloped Roof System)
Roof System Manufacturer:
p �'r7/�
Notice of Acceptance Number. I � F4& _ . .... • • � • •
Minimum Design Wind Pressur f p icable (From 7 alculations): • • • • • • 1 •
P1: •�.. . ..00
P1: P1: 0000 0 . 1
Deck Type: ���JIW
b►,�,` e 0 )•: •
�dJ 6 .. 6 •
Type Underlayment: G'`1r�,�,
12
Insulation: � � 1
1
Fire Barrier:
1
Ridge VentilaborY.7Fastener Type &Spacing:
Adhesive Type:
Type Cap Sheet: �� 1
1
_ 1
Mean Roof Height: Roof Covering:
JI
t
Type & Size Drip
Edge: L--- 1
FLORIDA BUILDING CODE -- BUILDING, 5th EDITION (2014) 15 39
1 1 1 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on !un 8, 2015 ]0:32:12 AM pursuant to License
Agreement. No further reproductions authorized.
Florida Building Code Edition 2014
High Velocity Hurricane Zone Uniform Permit Application Form
Section E (Tile Calculation
For Moment based file systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mr
values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable.
�+ Method 1 "Moment Based Tile Calculations Per RAS 127"
(P'•/3_�' X �`�j - M9 �`�) =Mr Product Approval Mr e"'",f
. •
9: ) =Mrz Product Abaro;al Mr AEi 4�- •.
(a-R X' - M9 4- A3) =Mrd 7•5--T Product AQQfAJal Mr .7 � � •
.... ...• . .
.... .... .....
Method 2 "Simplified Tile Calculation Per Table Below" •
...... .. . .....
Required Moment of Resistance (Mr) From Table Below Product Approval KA • • sees**
• sees • •
M Re uired Moment Resistance* 0 0 •
Mean Roof Height
Roof Sloe
15'
20'
25'
3Q.. • •�
60650
400. .
• • •
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
6:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
25.9
27.1
28.2
30.0
*Must be used in conjunction with a list of moment based tile systems endorsed bythe Broward County Board of Rules and
Appeals.
For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or
equal to the Fr values, for each area of the roof, then the the attachment method is acceptable.
Method 3 "Moment Based Tile Calculations Per RAS 127"
(P,: - x 1: x w: -1 W: x cos 0: =Frt Product Approval Mr
(P2: x 1: = x w:=_W: x cos 0: =F,2 Product Approval M,
(P3: - x 1: = x w:=__) W: x cos 0: =Fr3 Product Approval Mr
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
P1 or P2 or P3
RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
a
Job Site
Aerodynamic Multiplier
A
Product Approval
Restoring Moment due to Gravity
M.
Product Approval
Attachment Resistance
M,
Product Approval
Required Moment Resistance
M,
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplift Resistance
F,
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
I = length w = width
product Approval
All calculations must be submitted to the Building Official at the time of permit application.
MIAMI-DADE COUNTY
M1AP'1NQA►DE PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.zov/economy
Entegra Roof Tile, LLC
1289 NE 9`h Ave
. . .... ......
Okeechobee, FL. 34972 •
. .... %
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction .t�atw ials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER-Protititt Control•9ee4on to4y • •
used in Miami Dade County and other areas where allowed by the Authority Having JurisdiMM'(AHJ).. 0 0• •' • •
This NOA shall not be valid after the expiration date stated below. The Miami -Dade Cou>Ztyrrgduct Control Section •
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the rig:4.tD: $ave thtS • * -
product or material tested for quality assurance purposes. If this product or material failseto peisform in the accepkd..:
manner, the manufacturer will incur the expe such tes i nd the AHJ may immediately revoleeo,•rnodify; or
suspend the use of such product or mate within their jurisdiction. R reserves the right to revoke this acceptance,
if it is determined by Miami -Dade ounty Product Control Section at this product or material fails to meet the
' requirements of the applicable b code.
This product is approve as escribed\\herein, and has been designed
including the High Vel city urricane Zone of the Florida Building Code
DESCRIPTION: alen Spanish "S" Concrete Roof Tile
LABELING: Eac unit s all bear a permanent label with the i
statement: "Miami- ade C my Product Control Approved", unl
comply with the Florida Building Code
name or logo, city, state and following
noted herein.
RENEWAL of this OA shill be considered after a renewal pplication has been filed and there has been no change
in the applicable builds code negatively affecting the pe n�nance of this product.
TERMINATION of this will occur aft a expiration date or if there has been a revision or change in the
materials, use, and/or manufacture o e product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA 10-0518.04 and consists of pages 1 through 6.
The submitted documentation was reviewed by Juan E. Collao, R.A.
NOA No.: 14-0416.12
Expiration Date: 11/18/19
Approval Date: 11/21/
Page of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Galena Spanish "S"
Concrete Roof Tile, as manpfactured by Ynlegra Roof
• • •
Tile, LLC as described in Section 2 of this Notice of Acceptance, designed to comply witlf OO Ptorida uilq"ing Code • •
�
for High Velocity Hurricane Zone. For the locations where
the pressure requirements, as determined 6 *ApplicaW. •;.
Building Code, does not exceed the design pressure values obtain by calculations in compliartee•vith RAS 127 using
the values listed in section 4 herein. The attachment calculations
shall be done as a moment.W%t;d.systeV. • • • •
•
.... .... .....
2. PRODUCT DESCRIPTION
...... .. . .....
• • • • • • •.....
Manufactured by
Test :**;redact. .... ; .
Dimensions
Applicant Specifications
• • • • •
� DescT rim•
Galena Spanish `S' Roof L = 17"
TAS 112 High profile, interlocking; one piece, RS" •
Tile W = 10"
shaped, concrete roof tile equipped with
H = 2.7"
two nail holes. For direct deck or
Thickness: ''/z"
battened nail -on, mortar or adhesive set
applications.
Trim Pieces L = varies
TAS 112 Accessory trim, concrete roof pieces for
W = varies
use at hips, rakes, ridges and valley
Varying thickness
terminations. Manufactured for each tile
profile.
2.1. MANUFACTURING LOCATION
1. Okeechobee, FL
2.2. EVIDENCE SUBMITTED
Test Agency Test Identifier
Test Name/Report Date
Redland Technologies 7161-03
Static Uplift Testing Dec. 1991
Appendix Ill
PA 102 & PA 102(A)
Redland Technologies 7161-03
Wind Tunnel Testing Dec. 1991
Appendix II
PA 108 (Nail -On)
Redland Technologies P0647-01
Wind Tunnel Testing Aug. 1994
PA 108 (Mortar Set)
Redland Technologies P0402
Withdrawal Resistance Testing of Sept. 1993
screw vs. smooth shank nails
The Center for Applied 94-084
Static Uplift Testing May 1994
Engineering, Inc.
PA 101 (Mortar Set)
The Center for Applied 94-083
Static Uplift Testing April 1994
Engineering, Inc.
PA 101 (Adhesive Set)
NOA No.: 14-0416.12
Expiration Date: 11/18/19
Approval Date: 11/27/14
Page 2 of 6
Test Agency
Test Identifier
Test Name/Report
Date
. The Center for Applied
25-7183-4
Static Uplift Testing
Feb. 1995
Engineering, Inc.
PA 102 (2 Quik-Drive Screws, Direct
Deck)
The Center for Applied
25-7214-3
Static Uplift Testing
March, 1995
Engineering, Inc.
PA 102 (1 Quik-Drive Screw, Direct
Deck)
Redland Technologies
Letter Dated Aug. 1,
Wind Tunnel Testinf
9 * • •
'.Qyg' 1994......
1994
�. •
PA 108 (Nail -On) • •
.'
The Center for Applied
Project No. 307025
Wind Driven Rain• • • ; • •
0 Oct . 1994 .... : •
Engineering, Inc.
Test #MDC-78
PA 100 """
;.. • •;
Nutting Engineering
13343.1
Physical Propertie9 • •
. •luna 2007' '
....
TAS 112
.... .....
• •
Celotex Corporation Testing
520111-3
......
Static Uplift Testing.'..'
.. . .....
'.Mo' 1998: • • • •
Service
520191-2-1
PA 101 :of:*:
March 1999 .'
Walker Engineering, Inc.
Calculations
Two Patty Adhesive Set System
; •Ap�i�l 19990 • • • : •
Walker Engineering, Inc.
Evaluation Calculations
25-7094 .'.
February 1910...
Walker Engineering, Inc.
Evaluation Calculations
25-7496 90 •
.:A ep'ril 1996 '
Walker Engineering, Inc.
Evaluation Calculations
25-7584
December 1996
25-7804b-8
25-7804-4 & 5
25-7848-6
Walker Engineering, Inc.
Evaluation Calculations
25-7183
March 1995
Walker Engineering, Inc.
Evaluation Calculations
Restoring Moment Due to Gravity
09/14/09
Walker Engineering, Inc.
Calculations
Aerodynamic Multiplier
09/14/09
American Test Lab of South
RT0624.04-14
TAS 112
07/07/14
Florida
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product
Control office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 14-0416.12
Expiration Date: 11/18/19
Approval Date: 11/27/14
Page 3 of 6
4. INSTALLATION
4.1 Galena Spanish "S" Concrete Roof Tile and its components shall be installed in strict compliance with
Roofing Application Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight W (Ibf)
Length-1 (ft) •• th•w (ft ••
Galena Spanish 'S' Roof Tile
8.5
1.42 ... .. V-89'3
Table 2: Aerodynamic Multipliers - 7, (ft) .... •
.... .... ..
Tile
..�..� •..•.• ..
Profile
Direct,15,oft Applic tion "
Galena Spanish 'S' Roof Tile
0.235 •
Table 3: Restoring Moments due to G vity - 9 (ft-Ibf) •� •• • •
. .
Tile
2":12"
3":12"
4":12"
5":12"
6":12"
7":12" or
Profile
greater
Galena
Direct
Direct
Direct
Direct
Direct
Direct
Spanish
Deck
USGK
Deck
Deck
Deck
Deck
'S' Roof
6.20
r6.13
6.03
5.89
5.74
5.57
Tile
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Mechanically Attached Systems
Tile
Direct Deck
Direct Deck
Profile
Fastener Type
min 15/32 plywood)
min. 19/32 plywood)
Galena
2-10d Ring Shank Nails
28.6
41.2
Spanish 'S'
1-10d Smooth or Screw
5.1
6.8
Roof Tile
Shank Nail 2
2-10d Smooth or Screw
6.9
9.2
Shank Nails
1 #8 Screw z
20.7
20.7
2 #8 Screw
43.2
43.2
1-10d Smooth or Screw
23.1
23.1
Shank Nail Field Cli
1-10d Smooth or Screw
29 3
29.3
Shank Nail Eave Cli
2-10d Smooth or Screw
27.6
27.6
Shank Nails Field Clip)
2-10d Smooth or Screw
38.1
38.1
Shank Nails Eave Clip)
2-10d Ring Shank Nails 33.1 48.1
1 Installation with a 4" the headlap and fasteners are located a min. of 2 'W from head of tile.
2 When using only one fastener use the hole that is approximately 4 W away from interlocking edge.
NOA No.: 14-0416.12
Expiration Date: 11/18/19
Approval Date: 1.1/27/14
Page 4 of 6
OV
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
for Two Patty Adhesive Set Systems
Tile
Tile Application
Minimum Attachment Resistance
Profile
Galena Spanish 'S' Roof Tile
Adhesive
29.34
3 See manufacturer's component approval for installation requirements.
4 The Dow Chemical Company TileBond Average weight per patty 10.7 grams. • • • •
•
3MTM 2-Component Foam Roof Tile Adhesive AH-160, average weight per patty 8 grams. • • • • • • • •
Table 6: Attachment Resistance Expressed as a Moment - Mf 4ftwhR
for Single Patty Adhesive Set Systems
• • • • • • • • •
Tile
Amllmum AV Ahmed
Profile
Tile Application
02esi e
Galena Spanish 'S' Roof
3M- 2-Component Foam Roof Tile Adhesive AH-160
;••;•;
Tile
3W 2-Component Foam Roof Tile Adhesive AH-160
3$T�'•
5 Large paddy placement of 63 grams of 3MTM 2-Component Foam Roof Tile Adhesive AH-160.
• • • •
• •
6 Medium paddy placement of 27 grams of 3MTM 2-Component Foam Roof Tile Adhesive AH-160.
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Mortar or Adhesive Set Systems
Tile
Tile Application
Minimum Attachment
Profile
Resistance
Galena Spanish 'S'
Mortar Set
24.5
Roof Tile
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
OR
EfrJlif Eu=' R �
GALENA SPANISH "S" CONCRETE ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE
No.: 14-0416.12
i Date: 11/18/1
1 Date: 11/2 4
Pasel of 6
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
PROFILE DRAWINGS
GALENA SPANISH "S" CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
NOA No.: 14-0416.12
MMI-DADE COUNTY Expiration Date: 11/18/19
l Approval Date: 11/27/14
Page 6 of 6
MIAMMADE
MM
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.aw/economy
ICP Adhesives and Sealants, Inc.
12505 NW 44' Street
Coral Springs, FL. 33065 0 • • • •
. . .... ......
..
SCOPE: 000000
••••• .. • ..0 • ....
This NOA is being issued under the applicable rules and regulations governing the use o€c4s;uction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER-PjodtttJ Congal•Se;tion tore •
used in Miami Dade County and other areas where allowed by the Authority Having JurisdiCtfoY (AW). • • • • • • ; • •
This NOA shall not be valid after the expiration date stated below. The Miami -Dade Coar4-FroductOC4iro1 Se= 0 0
(In Miami Dade County) and/or the A14J (in areas other than Miami Dade County) reserve :he xiot to haveothis product
or material tested for quality assurance purposes. If this product or material fails to perforth in th2 accePWAUnner't'W • •
manufacturer will incur the expense of such testing and the AHJ may immediately revokes meaify, orosuspend theo0us0.
of such product or material within their jurisdiction. RER reserves the right to revoke this accePtoanoe, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polyset® AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 1 of 11
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset® AR-160 as manufactured by ICP Adhesives and Sealants, Inc.,v described
in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by.applicable ......
building code, do not exceed the design pressure values obtained by calculations in compliameeweth Roofing . .
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile "st�ft using ICP • • • • • •
Adhesives Polyset® AH-160.
.... .... . .
.... .... .....
PRODUCTS MANUFACTURED BY APPLICANT: ...... .. ..;.. •
. . ......
Product Dimensions Test Produc ascription. ..
Specifications
. . . . ......
ICP Adhesives N/A TAS 101 Two component pglytMhane;VM adhetyg..:
Polyset®AH-160 " ' .
ICP Adhesives Foam N/A Dispensing Equipment
Dispenser RTF1000
ICP Adhesives ProPack® N/A Dispensing Equipment
30 & 100
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
Tomball, TX.
PHYSICAL PROPERTIES:
Prove Test Results
Density ASTM D 1622 1.6 lbs./ft.'
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Ft2
Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch
Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -400 F., 2 weeks
+6.0% Volume Change @158'F., 100% Humidity, 2
weeks
Closed Cell Content ASTM D 2856 86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
MIAMMME COUNTY Expiration Date: 05/10/22
orpolApproval Date: 04/27/17
Page 2 of 11
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Center for Applied Engineering
#94-060
257818-IPA
25-7438-3
25-7438-4
25-7438-7
25-7492
Miles Laboratories
Polymers Division
Ramtech Laboratories, Inc.
Southwest Research Institute
Trinity Engineering
Celotex Corp. Testing Services
NB-589-631
9637-92
01-6743-011
01-6739-062b[1]
7050.02.96-1
P36700.04.12
P39740.02.12
528454-2-1
528454-9-1
528454-10-1
520109-1
520109-2
520109-3
520109-6
520109-7
520191-1
520109-2-1
Test Name/Reyort
Date
TAS 101
04/08/94
TAS 101
12/ 16/96
SSTD 11-93
10/25/95
SSTD 11-93
SSTD 11-93
,•,
•• •
ASTM D 1623
•
ASTM E 108
......
ASTME 108
••••••
ASTM E 84
•
TAS 114
• • •
ASTM D 1623
TAS 101
TAS 123
TAS 101
TAS 101
TAS 101
14492/95
12f W95
•••.••
U2/01/94
U30/93
..
•• •
11/i6/94
AU16/95
43•/I4f96
04/18/12
02/21/12
10/23/98
12/28/98
03/02/99
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
INSTALLATION:
1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH-160.
2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. Thaadkesive
attachment data is noted in the roof tile assembly NOA. • • • • • • • • • •
3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance T.& Roofinj 0eMplicatior1 • •„�
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and. Wiatenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed'HYMP AdWitrh and '
.... .. .....
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicato' *to the authoMy having • • •
jurisdiction. '
.. .. .. . ......
5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is Teg4qd before application •,
of any adhesive. The mix ratio between the "A" component and the "B" component shall be mainWvg4 betweW * •'
1.0-1.15 (A): 1.0 (B).
6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP*
Adhesives ProPack® 30 & 100 dispensing equipment only.
7. ICP Adhesives Polyset® A1H-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset® AH-160 has been dispensed.
9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details' herein. Each generic tile profile requires the specific placement noted herein.
NOA No.: 17-0322.03
MIAMFDADE COUNTY Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Minimum Paddy Contact
Minimum Paddy Gram
Tile Profile
Placement Detail
Area
Weight
Eave Course - Flat, Low, High
All Eave Course
17-23 sq. inches
45-65
Profiles
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches .
. '40....
Low Profile
#2
12-14 sq. inches
High Profile
#2
17-19 sq. inches
•... 30
...
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches a4 •
• 12 graxri � erpaddy
head of tile 9-11 sq. inches al .....
* •
•
.. . ....
overlap ..
'
.. .. . ....
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal:
am: per bead
edge) 20-25 sq. inches each,
• •
bead ..
• •• • " "
•
. .
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
ADHESIVE PLACEMENT DETAIL # 1
Me rom"h Pakllt"mrNmt fbaep faa+�.Hhrao>
Nnd•rfeym•rtt '�
1
j
flatter"\ optiattA
Es"Course
loin.2 Fascia
EweCfeSYr• �
4 Nall UNmugh plastic ce rnent
(when required)
2fn.wfd•
sattens optlatal
Paddy 48•rt•et1h Td•i I
LM clesun
Fascia
Flailth 0 olntic
ttatterr rpuFred) Paddy is•n.•thlilel
tktdwl•ynrent o
2 in.wlda
Battens
opttanal
►� Esre Course " •
Fasda
Weephok
to ht. on. Ern dosure
Oripa"*
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set. •. • •
• • •••• ••••••
2. Continue in same manner• Insure approximately 17
(109.7 cm2) — 23 (148.4 tsquare in ttjch• adhesive• • : •
contact with the undersidd bfthe tile. • :0000:
•
*0000
•• •• •• • ••••••
•
•••••• • •
• • • • ••••••
Medium Profile / Double;Pap*Tile 06660 a 000000
• • • • • • • •
• 10 •
1. Starting at the eave course, apply a dUhilhum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlook of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlook of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 6 of 11
ADHESIVE PLACEMENT DETAIL # 2
Man ar ouOptaaletoment V•�/pfl<•n•athTiM)
twhen raq**O
uradadtym«�t '
1
z in,
6twf•ura ,�,•
RUM
z
E•vadoturo �
Nall through plastic Bement
(when requi►edl
E•r•CM.un
F•.rfi•
04
.•.
APPROVED
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately. t ! �1 Q9.7 cm2)
— 23 (148.4 cm2) square inch adhesive cUtIct with"V
underside of the tile. • • • • • • •
•..... . ....%
2. At the second course, appl36 aiwnimum.X.00.8n4j •
x 7" (177.8 mm) x 1" (25' ommT foam petWonto tha. • •
underlayment positioned m n un jorrthe. • • : • • •
strengthening rib closest tb'th0bverlocko8f the tile • • • •; •
being set. 00
. . . . ......
3. Continue in same manner! 14a j approj�n#tely 1011, • • •
(64.5 cm2) - 12 (77.4 cm2) square inch'oAlkstve
contact with the underside of the tile.
Medium Profile / Double Pan Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cm2) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
Nam fteugh phs* ca
twlun mqui►ed)
P•ddy 10•nwhTil•)
tlndai•yr►+•e�t
7 1e.
8ueens epNoeal
'�.,,,.
R..
EereCourse _
.s:1a
` Wvhe"
loin.
2W
few dame
Orlp tdP
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile. ....
• • •••• ••••••
2. At the second course, appyy a minimum 2� 11 0.8mm)
x 7" (177.8 mm) x 1" (25.4Kn=n)-foampaddy onto t1V
underlayment positioned An under tAe pan :....:
portion of the tile closest tolillbverlook'of to the • •
being set. �•�• ��•� •••••
...... .. . .....
.. .. .. . ......
3. Continue in same manner. J4uvA approximately 17"
(109.7 cm2) - 19 (122.6 crn'2) square inch adhesive • • • • • •
••••••
contact with the undersideof the; ile. • • •
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8 of 11
ADHESIVE PLACEMENT DETAIL # 3
ful)throuOplast)ccMent
vadd)r(betweenties)
(when required!
flattens opt)ata)
`
'
Psddflundertile)
e pal
artopolde
o
UngiepaddT
10ln
�a
:
2
Farecloswe
Rat/Low Proma Tile
Nall through plastic oenrent Sb►g)e paddy under tie
(when required)
Paddy (between ties)
Battens Paddy (under tie)
oopdonal
PW
of
1 ain. zs)nn.
sirletpaddy-
t01n. `• tin.
Eare Closure
Eare Course Fascia
Medium ProflleTile
1. On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (101.6 mm) up from the cave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 in (109.7-148&l j pj� of • •
adhesive contact with thg;mcjgrside.of the the . •
.
...... :***a*
......
......
2. Apply a 4" (101.6 mm) x 4l101.6 pui�$1" (25.4 •
mm) foam paddy onto thVddderlayn*hT just belat:
the second course line 13dfitibhed foaM paddy •
.. .. ......
under the strengtheninginb..fo: flat tile,.or under the • •
pan portion of the tile, Zlosesrto the underlock fg ; • • ; •
the second course tile tQ be ipstalle(Z'hfsliTe
......
approximately 8-9 in2 (Sa X--A.1 cm24 of adhesive •
contact with the underside of the tile.- • -
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
Hail through plastic
Since paddy under We
(When required)
Paddy dWtWeen tiled
Battens
optional
�
Paddylundertilei
pad
r
an,►
+4 41n
Shvfie
paddy -
top tie
Eave coarse
Weephole
101n.
tin.
Eandosure
Dripedge
High ProilleThe
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cm2) - 11 (71cm) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cm2) - 9 (58.1 cm2) squaft!"Wh
adhesive contact with flee underside of We tile at • • • : •
the head of the tile. Continuein salve rnalmer. •
...... . ......
.... .... . .
•••• •••• •••••
•••••• •• • •••••
•• •• •• • ••••••
•
. . . . ......
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
1) Place enough adhesive to achieve 65 to 70 sq. in. Steep pitch applications
in contact with the pan tile. when required)
2) Turn covers upside down. Place adhesive in
to 1 in. from outside edge of cover tile.
Then install the tile. Ensure 20 to
25sq. in. contact area. r °
IUnderlayment
n °
Eaveclosure
(motar shown)
Fascia Board
Remove top potion of the eave course cover tile. Abut to second course of
pan tiles. Ensure eave end of pan and cover tiles are flush at eave line.
Two Piece Barrel - High Profile Tile
APPROVED
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocking until adhesive has a chance to
cure.
• •••• ••••••
2. Continue in same ln•vo liXinging twa pan
courses up toward the.ridga. Insur..... • • .. : •
approximately 65 (4 W.4 m) — 70 (4-51.6 cm�� • • •
square inch adhesive•mmait wit11,llvaijderside •
of the pan tile. "" "" ":
3. Turn covers upside down p exposing tke underside • •
of the tile. Apply a rronithupi 1" (25.4 lnm) x IOIL
(254 mm) bead of adhesive direcd �'oh'the inner
edge of each side of fhoco;er tile. 4+ea-v� •
approximately 3/4" (19 mm) to 1" (25.x1 mm)
from the outside edge of the tile, inward, free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan tile course. Insure a minimum of
20 (129 cm2) - 25 (161.3 cm') square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11
MIMIA-Ml-
� MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.zov/economv
Polyglass USA Inc.
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
SCOPE: ••••
This NOA is being issued under the applicable rules and regulations governing the use of c(:nstq?4ion mz ttfi*als. The"":'
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Pr('dtzct'ControLSovtion to be •
......
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdic tiok e(AHJ).• •
......
This NOA shall not be valid after the expiration date stated below. The Miami -Dade Count} product Contorol Section* ....
•
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve tki .rj< to have tips .,;..'
product or material tested for quality assurance purposes. If this product or material fails to 9irffpn1t in th'e.actcepted ......
manner, the manufacturer will incur the expense of such testing and the AHJ may immediatal�r.rewoke, modify, or •
suspend the use of such product or material within their jurisdiction. RER reserves the righhto rewke thj$ g�CgptancC,""'
if it is determined by Miami -Dade County Product Control Section that this product or material Mils to nTeet the :....:
requirements of the applicable building code. •
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Semino.,
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test Product
Product
Dimensions
Specification Description
Polystick IR-Xe
65' x 3'3 3/8"
ASTM D 1970 A fine granular/sand top surface self-adheril@� APP
Manufacturing
Or 65' x 3'
polymer modified, fiberglass weinforced, biP"sous • • • �; •
Location #1 & #2
60 mils thick
sheet material for use as an underlayment %s ped roof
assemblies. Designed as an W n Min shield. • • • • • •
Polystick Dual Pro
6F x 3'33/8"
TAS 103 and A rubberized asphalt self-adhitKtit!glass-Q5e&Pglyest& •
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing meml5ff&. Desig"eTas a :•••
. .....
Location #2
..
metal roofing and roof tile under1.gZ.lent. • •
Polystick Tile Pro
61' x 3'3 3/8"
TAS 103 and A rubberized asphalt self-adhCIA$'Qlass-fibeepolyester •.
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing merbrane' Desi •r+ad �9 a metal • • • •
. . � . •
Location #2
roofing and roof tile underlayment. • • .... •
.. • • • •
Polystick TU Max
65'8" x 3'3-3/8"
TAS 103 and A rubberized asphalt self -adhering, polyestellreinforced
Manufacturing
60 mils thick
ASTM D 1970 waterproofing membrane. Designed as a a roof tile
Location #1 & #2
underlayment.
Polystick TU P
32'10" x 3'33/8"
TAS 103 and A rubberized asphalt waterproofing membrane, glass -
Manufacturing
130 mils thick
ASTM D 1970 fiber/polyester reinforced, with a granular surface
Location #2
designed for use as a tile roof underlayment.
Polystick TU Plus
65' x 3'33/8"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
(Surface Printing)
80 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Manufacturing
roofing and roof tile underlayment.
Location #1 & #2
Polystick MTS
65'8" x 3'33/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Polystick MTS Plus
65'8" x 3'33/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Elastoflex S6 G
32'10" x 3'3 %"
TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing
ASTM D 6164 with a sanded back face and a granule top surface. For
Location #2
use in roof tile underlayment systems.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
Trinity ERD
P10870.09.08-R1
TAS 103
12/04/08
P10870.04.09
TAS 103/ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
14=1/10
P33370.03.11
TAS 103 • • •
• • 0&62/11 .... � •
P33370.04.11
ASTM D 1623 • •
Q.4t;6/11 • •
P36900.09.11
TAS 103/ASTM D4798 &'GI33
09/01/11
P37300.10.11
TAS 110/ASTM D4798 &�tii�`fb
lb/19/11 :....:
P40390.08.12-2
ASTM D 1623 ••
•„0,8*J67/12 �•�•••
P37590.07.13-1
ASTM D6164 ......
..07J02/13 .•;•.•
P45270.05.14
TAS 103, TAS 110 & ASTMN1.6`23
%0502/14 ......
P46520.10.14
ASTM D 1623 • • • • • •
10/03/ 14 •
P44360.10.14
TAS 103 & TAS 111)
;. JA07/14 • • • • • •
P43290.10.14
ASTM D 1970 & TAS:1 IQ,
10/17/14 :....:
PLYG-SC10130.06.16-3
TAS 103&TAS 110 •
•0/17/16 •
PLYG-10130.06.16-1
ASTM D1970 & TAS 110
06/27/16
PRI Asphalt Technologies
PUSA-035-02-01
TAS 103
09/29/06
PUSA-055-02-02
TAS 103
12/10/07
PUSA-089-02-01
TAS 103/ASTM D4798 & G 155
07/06/09
Momentum Technologies, Inc.
JX20117A
TAS 103/ASTM D4798 & G155
04/01/08
RX14E8A
TAS 103/ASTM D4798 & G155
11/09/09
DX23D8B
TAS 103/ASTM D4798 & G155
02/18/10
DX231)8A
TAS 103/ASTM D4798 & G155
02/18/10
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
MIAMI•DADE COUNTY
•• �
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
NOA No.: 17-0614.22
MIAMI•DADEOWNTY Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1:
Wood, non -insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E(1):
Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet:
One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening:
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane:
Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Mai' Polystick
TU P, Polystick TU Plus, Polystick NITS or Polystick NITS Plbs, calf-adher&d.*
Surfacing:
See General Limitations Below. ...... :""' ....:.
Deck Type 1:
.... .... . .
Wood, non -insulated • • • • • • • • • •; • •.
Deck Description:
...... .. . .....
Min. 19/32" plywood or wood plank •. •..' ' �.'. • .. �. •.
System Type E(2):
Anchor sheet mechanically fastened to deck, membrane adhered ;••;•; •,
Anchor/Base Sheet:
. . . . ......
One or more plies of ASTM D 226 Type II or ASTM D 2626. ; • • • • • •
Fastening:
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a Aitnidlum 4" titid jap. (fbr •
base sheet only)
Membrane:
Elastoflex S6 G, hot asphalt applied
Surfacing:
See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick NITS Plus, self -adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Membrane: Polystick TU Plus, self -adhered.
Surfacing: See General Limitations Below.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of 8
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolljj ft.
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in botk aVpr,yons. ; • • • • • ....
;
6. Roll or broom the entire membrane surface so as to have full contact with the surface,•giving special attention: ....
to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assem�"QQrrent PrQQuQt Control • • •
Notice of Acceptance. '
.. .. .. . ......
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. TITOMpliing tape shall be •,
pressed in place and formed around the protrusion to ensure a tight fit. A second laybr of PolystiU.4411 be
applied over the underlayment. • • • • • •
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Ex osure Limitations (Days)
MTS
IR-Xe
Elastoflex
S6 G
TU
Plus
TU P
Tile Pro
Dual Pro
TU Max
MTS Plus
Winter Haven, FL
180
90
180
180
180
180
180
180
180
Hazelton, PA
N/A
90
N/A
180
N/A
N/A
N/A
180
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
NOA No.: 17-0614.22
MIAMI- DeCOUNrr Expiration Date:-06121
Approval Date: 07/06/17
Page 5 of 8
Rule 61 G20-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications. ....
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies,thq.ihaximun'1184 slope"
shall be as follows: (See Table Below) •
..0000 • •••..•
Tile
Polystick
Elastoflex
Polystick TU Plus,
Polystick
Polygtfc9t"
System (E3) ;
Profile
MTS
S6 G
TU P, Tile Pro,
TU Max
MTS A*u* * •
MTS alas with
Dual Pro
T>oJ Plus g.
• • • • • •
•
Flat Tile
Prohibited
4:12
6:12
6:12
5:182 • •
• 6: ?2 •
without battens
:":':
'
Profiled
Prohibited
4:12
6:12
6:12
4:12
• • 6! 2
Tile
without battens
• •
'
. .
The above slope limitations can be exceeded only by using battens in accordance with the Approvea'I'i% System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for
all underlayments except Polystick MTS which shall be loaded onto battens.
m
CL
0
N
IjI wil L"Iji
POLYSIICKTU Plus
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 6 of 8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for appwNV %ovided
that appropriate documentation is provided to detail compatibility of the products, wilad uplift resin Pa M , and fire •
testing results. • • • • • • •
...... . ......
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTIGdMEMBRAr 9 •
.... .... .....
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPFist • •]P .. ICf ��. APPM • •IONS. • • • • •
......
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMDLTNDATIONS.. . •
. 0 . . 11* . ......
1. Polyglass does accept the direct application of Polystick underlayment membranes to �vogd •decks.- Insta lers are • • •
cautioned to refer to applicable local building codes prior to direct deck installation to 2flsuft this iS ar.Ceptable". •
Please also refer to applicable Product Data Sheets of the corresponding products. • • •
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 V metal disk as
required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes of 7/12" or greater. It is suggested that on pitch/slopes in excess of 6 '/4"/12", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 7 of 8
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical 9:r,jGCs •, •
Department at 1 (800) 8944563. '
14. Polyglass recommends that applicators follow good roofing practices and applicable Oro* � u res as ou*tlined by
the National Roofing Contractors Association (NRCA). • • • • • •
..•. •.•. . .
•..• ..•• ....•
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SWIM: APPIXV;ONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOIV�F�N• CATIONS • • • •
. . • • ••.•••
END OF THIS ACCEPTANCE :....:
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 8 of 8
SECTION 1524
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the "mr with
the required roofing permit, and to explain to the owner the content of the section. The provisions ofl�e0ien R440Q• • • •
govern the minimum requirements and standards of the industry for roofing system inslalleli4s. Ad¢i gi;4V, the • •
following items should be addressed as part of the agreement between the owner ant tttt: rftractor'The owner's*
initial in the designated space indicates that the item has been explained. •••••• •
.... .... . .
.... •.•• •...•
2. Renailing wood decks: When replacing roofing, the existing wood tadf deck%al bbve to 0 0 0 o 0 0
be renailed in accordance with the current provisions of Section R4403. (The soofdeck is usually •
concealed prior to removing the existing roof system). ' : 0 •. ••:•
•• . •• • • •
4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the goo{decking
can be viewed from below. The owner may wish to maintain the architectural appearance; therefore,
roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of
maintaining the appearance.
6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is
not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this
discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow
scars in accordance with the requirements of Sections R4402, R4403 and R4413.
Owner/A gent s Signature Date ontractor Signa Date
/ c96 /ale
Property Address
Revised on 7/9/2009 LD;07/01/2015;
Permit Number