Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
MCC-18-3321
Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Permit NO.: MCC-10-18-3321 P �it� Permit Type: Mechanical - Commercial Work Classification: Alteration AI LF UM Permit Status: Approved Issue Date:11/15/2018 I Expiration: 04/29/2019 Location Address Parcel Number 11300 NE 2ND AVE, Miami Shores, FL 33161 1121360000050 Contacts BARRY UNIVERSITY INC Owner SMART AIR SYSTEMS INC Contractor BARRY UNIVERSITY STEVEN CHARNEY 11300 NE 2 AVE, MIAMI SHORES, FL 331616628 Business: 9549681288 Description: REPLACE 10 TON RTU CHILLED WATER UNIT Valuation: $ 49,000.00 Inspection Requests: I Total Sq Feet: 0.00 1 3U5-762-4949 Fees Amount Application Fee - Other $50.00 CCF $29.40 DBPR Fee $22.05 DCA Fee $14.70 Education Surcharge $9.80 Permit Fee $1,420.00 Scanning Fee $9.00 Technology Fee $36.75 Total: $1,591.70 Building Department Copy Payments Date Paid Amt Paid Total Fees $1,591.70 Check # 8806 10/31/2018 $50.00 Check# 34924 11/15/2018 $1,541.70 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate arXid that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above name a t o do the work stated. J11i5bp Authorized Signature: Owner / Applicant / Contractor / Agent Date November 15, 2018 Page 2 of 2 y BUILDING PERMIT APPLICATION ❑ BUILDING ❑ PLUMBING ❑ ELECTRIC MECHANICAL Miami Shores Village Building Department RECEIVED 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Q / Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 2011 Master Permit No. Mc,C 6 -3321 Sub Permit No. ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 3 6 CC G Z r 2 4V e— �4 A (( iZov SS C l ILi 'h J City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): a G Y co Ur i J2r S �'s'�1 Phone#: Address: 113 0 d K Zn 2 Av� City: Mt o rY6 State: Ir L A- Zip: ? 3 (C� Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: S,r,(17 C', r Sv1at ry-, S 1 ►J C Phone#: � Sri 14 � - ( Z?S Address: 1 % 3 1 3c. r� r �- i2.0 ck a City: Mc...rrscAke— State: rr-) l'r_ Zip: 33 U Co 3 Qualifier Name: C, ��` (w eJ-� Phone#: ") S `i q( State Certification or Registration #: Gar C. Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State Value of Work for this Permit: $ C4 00 Square/Linear Footage of Work: _ Type of Work: ❑ Addition ❑ Alteration ❑ New Repair/Replace Zip: ❑ Demolition Description of Work: r I2 IT V C_ hllll -f C Llzk4� L.Y11 Specify color of color thru tile: Submittal Fee $ Permit Fee $ Lk CCF $ CO/CC $ Scanning Fee $ Technology Fee Radon Fee $ Training/Education Fee $ DBPR $ Notary $ Double Fee $ Structural Reviews $ (Revised02/24/2014) Bond $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) ____ Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with on estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. 1 r^a nce of such posted notice, the inspection will not be approved and a reinspection fee will be charged. ) ."._ _ Lkli—,�iioi OWNER or AGENT The foregoing instrument was acknowledged before me this 1� day of 0V/L , 20 1,� by JAOJ- AL, who is personally known to me r who has produced as identification and who did take an oath. NOTARY Print: Seal: -Oft& N0Wy PW ft state ar FW4& ;P Jeffry J Yao My C*mn*aion PF 1mdt orA Expbas 11/12120/8 APPROVED BY The foregoing instrument was acknowledged before me this 13 day of (f)4 QM- . 20 �� , by who is personally y known to me ho has produced as identification and where an oath. NOTARY PUBLIC: Pri Examiner ###Rif#i#i###!!#iliiiiifii!###iiiii!##ii»liii Zoning Structural Review Clerk fRevised02/24/2014) -JC -4-- t 6� C ?-r 4: - 09/20/2018 Bart' University — Landon Hail RTU9 140 NW 115th Street Miami Shores, FL 33168 Attn: Al Halliday '&l0lNNA/iT A o-#R SYSTEMS, INC. Service / tnstallalion / Mainlenance Re: Replace Existing DX RTU-9 with Chilled Water RTU Smart Air Systems, Inc., proposes to provide all labor and materials to replace the existing direct expansion package unit with an equally sized chilled water unit, modified as discussed, Per the following scope of work: Included: • Provide engineered stamped and sealed drawings for mechanical and electrical permits. _ • Open permits with local authorities. -- • Disconnect existing electrical and controls wiring for RTU-9. �— • Remove unit and dispose offsite. _— • Provide and install (1) wind loaded adapter curb and fasten to existing roof curb, fasten per wind load detail. — • Provide and install (1) new chilled water roof top air handler with the equivalent design specifications as original roof top unit. Including: — o Larger capacity coil for better dehumidfication. _— o Adjustable outside air damper for improved air balancing in kitchen. o Two way modulating chilled water valve. • Installation of new 30-amp fused disconnect on roof. — • Replacement of existing liquidtite conduit above roof level. — • Furnishing and installation of conduit and wire to connect new disconnect to new unit. — • Provide and install new chilled water piping from existing chilled water piping to new unit. -- • Insulate new piping to match existing. • Provide and install new RTU de in ductwork as required. _ • Provide and install (4) new linear supply diffusers, including collars, cans and flex duct. — • Provide and install (4) new one-way supply grilles at hood. • Reconnect existing controls. — • Star�up and test operation. -� • Call for final and close permit, Not Included' 1. Any work not stated above. 2. Test and balancing of kitchen. Your price for the above work will be $49.960,00 including applicable taxes. This proposal is based on performing after our normal working hours of 8:OOAM to 4:30PM, Monday through Friday, If you have any questions concerning this proposal, please do not hesitate to contact us at your convenience. We thank you for this opportunity to be of service. Payment Ierms: Per AIA scheduled billing. Customer agrees to pay all court costs and attorney's fees should legal means be necessary for collections. Very truly yours, Jamie Cumming Commercial Service Account Manager Cell: 305-407-5334 ACCEPTED BY TITLE DATE 1731 Banks Road. Margate, FL 33063 Phone (954) 968-1288, FAX (951) 968-5509 CAC 056916 4.4 PERMIT #: _ w Miami S DAIS- Buildinj 10050 N Miami Shores, wKlw- - _. a s Tel: (. _ BLDG D� yr' g R C SUS�A( CONDITIONING R�PNT OCT 3 1 ���� STATE Ati ' _GULATIONS PEI cl(t4is form must accompany ALL air conditioning replacement pgrmit.applic n its own'ilka sheet. Multiple units on single sheets are not acceptable. MC change -out must Job Address (where the work is being done): kk 3 M tr '_ �a QJp_ Lax& Q>>• - iSs��• L �ii . • T • • City: Miami Shores Village County: Miami Dade Zip Code • • • • • • • • • • • • • • • 000000 9• • ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CON&"W* * SLAB • • • � • •: • • . ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION: • •: : • • • • • • • • A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS • • • • • • • • • • AHRI DATA SHEET REQUIRED • . . . . ...... Change disconnects means: YES NO ARHI Sheet ttached: YES • n6 n8 ❑ ❑ ❑ NO Contragft Ji►hached: Yi66. � • • • • n �A UNIT BONG REPLACED DATA NEW UNIT MANUFACTURER AHU or PKG. UNIT MODEL p TSC lot A a 4oA 13 AC3 COND. UNIT MODEL K G C'fl n /' KW HEAT NOM TONS AHU Cu PKG ZI. 1) M.C.A AHU CU PKG AHU CU PKG , 2) M.O.P AHU CU PKG ANU CU PKG Lk t0 3) VOLTS AHU CU PKG t4Q PKG UNIT / / PKG UNIT ' EER/SEER YES NO REPLACING DUCTS YES NO YES NO REPLACING THERMOSTAT YES NO YES egi5 NEW 4"CONCRETE SLAB YES YES <&M> NEW ROOF STAND YES N YES 0 NEW RETURN PLENUM BOX YES 1. Minimum Circuit Ampacity (Wire Size): 6 V-AW(-- 2. Maximum Overcurrent Protection (Fuse/Breaker Size): 3. Voltage of Circuit (208/240/ 80): 4. Size Disconnecting Means: 5C Contractors Comps . r State Certifi a or Re ra n Nal— G© 5 jRevueWZ124/2014) -Phone: �S-Qt�og-rZ�Sg of Competency No. Date: / U f 6� ��f Skyline® Air Handling Unit !' IIDAflrUi`J h Job Name Barry University Landon Kitchen RTU-9 October 24 2018 Submitted By` _ TJ Software Ve ion 11.62 llnit_Tag - RTU-9 Acc 4S -10-24 [ Unit Overview OAH009GDAM 3260 'Not including base rails, coil connectors, drain connectors, vestibule sections, control boxes and hoods •••••• • Unit • Modc_I`" N ben OAH009GDAM • • oval: ETL Listed / ETL Listed to Canadian Safety Standards (ETL Label / EFL4Llebe1) • Outer Panel: Painted standard G60 Galvanized Steel •... wrier: Galvanized Steel (unless noted per section) • • • • Insulation: R-13 Injected Foam .. .. •, • • �' . Unit confisuraaon: I nline horizontal Drive (Handling) Location: Right Base: Curb ready - Wall Thidmess: tin Roof curb Kit 0 in Altitude: 0 it Parts warranty: Standard One Year Mixing Box Portion 1 Dampers �RatedCFM Air Pressure ... ? QwMlt1i Hoods •.l Size (length x width) 'Location Type Otap r r Overall opening Outside Air 10 in x 50 in 6 in x 40 in End UltraSeal low 978 cfm 0.03 inswg 1 Fitted Leak Return Air 16 in x 50 in 12 in x 40 in Bottom UltraSeal Low 2282 cfm 1 Leak . � _ _ — — — - .. _ _ .. — � — _ _... � _ Fpte'► [lab . _ � .,, —..,� _ ... � _ _._.._ s � ._ � _ ., .._ Type Efficiency Face Velocity Face Area Alr Vokxne Filter Loading Pleated MERV 8 325 ft/min 10.0 ft' 3260 cfm Side Air Pressure Drop Number of Filters Hewn Width Depth Clean Air Mean Air Dirty Air 0.13 inWc 0.56 inwc 1.00 inWc 2 20 in 2 12 in Location ^ 1T Width _ Drive side 20 in 24 in 2 in 24 in 2 in Opening Outward Page 1 of 4 www.DaikinAuoiied.cg Skyline® Air Handling Unit Chilled Water Coil CotlMode'I� — .. _ .- Total Gpatity Sensible Capatity� Number of Cops- Number of Rows'' Flns per inch _ Tube Diameter j Tube Spadng (Face z Row) SWH0608C 139105 Btu/hr 102443 Btu/hr 1 8 6 0.625 in 1.50 in x 1.299 in Ab Vok! ne, . • AWTemperature- Coil Air, :Finned Finned Fa eArca IFace, - Enterli L"W14 - Pressure_ Height Len'th Velgdty Dry Bulb Wet Bulb Dry Bulb Wet BulbP 3260 cfm 81.8'F 66.71 53.1'F 52.6'F 0.82 inwc 30 in 41 in 8.54 ft' 382 ft/min water flow Rate Pressure Drop Velocity Volume Weight Piping Vestibule Entering Leaving 45.0'F 56.0'F 25.40 gpm 7.50 ftHd 2.70 ft/s 9.0 gat 81.00 lb -in Connection (Oats Per Goan Min. Fin surface Miss. Tubs Wall : • &Ing Factow ... • • Type, size Location Material Temp. ssBi(pye•Te6p. •. • • .' Threaded 1.50 in Drive side Carbon steel 45.0'F •45.8 �• • • • • 9.0oo ...... Material Orainle • • Drain side' .'. • • • Fin Tube Header Case •' • • ' ' • • Aluminum .0075 in Copper .020 in Copper Stainless steel Stainless steel -Drive side ...... ••...• . . ...•. AHRI 410 Ceidfication Certified in accordance with the AHRI Forced -Circulation Air -Cooling and Air -Heat hg bits Certification Programana5• • ^� �'1 which is based on AHRI Standard 410 within the Range of Standard Rating Conditions Ifsted in•'TaMj of the• • "' • Standard. Certified units may be found in the AHRI Directory at ww4ahrJaisector4rg : • • • • Access Section 0.00 inwc Location Width Opening Non -drive side 12 in Outward �-1 1111� Page 2 of 4 www.DaikinAoolied.com Skyline® Air Handling Unit ! f 311trom Supply Fan_Performance Air Volume Static Pressure Blake Horsepoviw Speed Outlet Velocity External Total cabinet Operating Mazbnuni 3260 cfm 1.20 inwc 2.26 inwc 0.00 inwc 2.83 BHP 1681 rpm 2518 rpm 3105 ft/min Fan Data Fan Type Blade Type / aria Quantity of Fans Wheel Dliimeter Number of Blades Discharge Motor location Centrifugal DWDI Forward Curved / 1 10.62 in N/A Top horizontal To Side of Fan 2 Moo D } Power Electrical Speed EHidency Enclosure Frame Size Supptla Number of Lock R4W, • ; jutl load Supply Polo • Curredi Current e e • • . 3.0 HP 460/60/3 1750 rpm Premium ODP 182 T frame Generic 4 ' 28.2 a"O". 4.2 A '. V/Hz/Phase ••••••• •••• •••••• Isolator Type: Spring '00096 • • • PackW Data!t ::'0 400 • • •ti "j• • Fan Sheave Motor Sheave Belt Number of Belts Actual DrIW S.V ' Bearing TV" AK49H AK46H A26 1 i.lg • ": " Sta ndard - L50 (2U0K I : : . •Daikin Applied reserves the right to provide a different but equivalent drive package • • • • • • " __ __ _.. _ - _ ._ _ VFD/Staner/Disconnect Qata • • • • • • • j • Selection Type: VFD Vendor: DaikinApplied '• ' Voltage: 460 V Height x Width x Depth: 11.731n x 5.26 in x 7.80 in Mounting: Door Side Enclosure: NEMA 3R VFD Quantity: 1 Location Width Opening Drive side 28 in Outward Plenum Section Opening Location Openin; Size Ali pressure prop Bottom 12.00" x 50.00" 0.08 inwc ,.--,err Location Width Opening Drive side 12 in Outward SoundUnit .s Type 63 Hz 125 Hz 250 Hs SOD Hz 1000 Hz 2= Hz 4OW Hz am Hz Radiated: 76 79 66 62 63 53 46 51 Unit Discharge: 81 84 78 77 79 75 74 71 Unit Retum: 76 79 67 67 69 65 61 55 Page 3 of 4 www.DaikinAoolied.com Skyline® Air Handling Unit !- DAprprd Shipping - Sias& Length - w_eight� _� Come wei�Ls (tb} _ - - Centel of Gravhy (in►_ �_ s In Ib,r Pr P2 TM :P4 - !XX 1 118 1780 SOS 443 385 447 55 25 21 Entire Unit 118 1780 0 0 0 0 55 25 21 YY • ' rian view ' • • • • XX• NOTE. Special components aren't included in the corner weights and center of grovity data. • • • • • AHRI Certification Supply fan performance is certified in accordance with the Central Station Air -Handling Unit Certification Program, which is based on AHRI Standard 430. J — F P2 — %1. FP3j Air Flow ""' • Fi ••''••• P4 • .... 1. As a standalone component, unit meets or exceeds requirements of ASHRAE 90.1- 2007. The approving authority is responsible for compliance of multi - component building systems. Page 4 of 4 www.DaikinAOalied.com j� S _ Non/Elevation - No, Ends P,adur{' B,NFne Aw Handic, tAndel: U4kiW7GUAM 9 n fit. fypr gvlr,Fp4w M( wx F7 . P.yn1 Darr {w.F 1 'A..ns1G m _........._ Catxq a .«...r.SY t4kUdC 7o1a14pe tk li9 sosoeiwr. , LO 12- � S,ppvrrf .. i r.n Ty{c r I..(. AWVW �r. F /lueltuss) lU it {} Ae,FL--• Ilrq.0 aln f P 1.5p eery.+.• Ldnp VfD bif Srnx J.IVIn .� KexhL D— ilw-rl la.rn a M, m { IMnrrtISK1.Qt .� Open ISne 41-50a F leyhr Ux. jw,1•Y 17 xr, a 36 m .. Dwnno e„»rn,wn, ,pawn a•e ro. un, Doti, '�� �`�erl.+uf,�eLow.eky,.luFJ,n+uy,•..er 'V" ¢non1an. ti^uv,tw I rdt tag•a 119Are qt. IOJd tu„:rf,rn-n,.Ln appl,w r,,.n,lr.,e;, OF P•Dlert Name 8a FV Unrvmsll Laedm t,Utlen RUsOnl+e+e _ ': ewrw,en Nr •w.+r.+o-c v..,ut ...-.._"frc.u,v _.. fG., _gym. `�1. ._warn ...tom ..,.fan..._... •rlw, .«.+...An .aw�rp,.w vwf. nk: •• ••• • • • • • •• • •• • • • • ••• • • ••• ••• • • •,i• • • • • • • • • • • •• •• • • • •• • • • ••• • • ••• • • • • ••• • • • • • • • • • • • • ••• • • • ••• • • Type X I Y Z I Wid I Hgt Mixing Box ® utside air damper 0.00 8.00 26.00 38.00 2.00 eturn air damper 6.00 8.00 6.00 38.00 8.00 lli-Onum ec ion pening 104.00 2.00 6.00 50.00 12.00 Opening dimensions shown are for unit only, refer to curb drawing for duct opening dimensions. Note: Dimensions are measured from the origin point. f �i n r R. PLAN VIEW now r ® I i i it I - c[1�+ri 1W ELEVATION VIEW • • • • 000 • • • • • Opening/Damper Connections Unit Tag; RTU-9 Acc QS - 10-24 Sales Of&tR DailAn Ap ied utff'Fjorid% ; "'DAM IN Product: Skyline Air Handler Project Name: Barry University Landon Kitchen FM0atf$pller:: • : • ; • • • • • 13600 Industrial Dark Blvd, Mnneapolls, MN 55441 Model: OAH009GDAM Oct. 24, 2018 1 Ver/Rev: I Sheet: 1 of 1 Scale: NTS tolerance:+/-0.25" 1 Dwg Units: in wwwD-AInnpolied.com Software Version: 11.62 • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • LEFT ELEVATION VIEW r l o� i { of Coil and Drain Connections Unit Tag: RTU-9 Acc QS t.lo-24 Product: Skyline Air Handler Project Name: Barry university Landon Kit Model: OAH009GDAM Oct. 24. 202s 1 v.,/Rev: I Sheet: 1 of 1 Type X I Y Z Diam .hilled-Water col © ondensate drain Conn: 27.94 2:90 9.83 1.25 old water inlet: 37.85 7.00 12.81 1.50 old water outlet: 28.73 -7.00 41.19 1.50 Note: Dimensions are measured from the origin point • • • • • • • • • • • •• ••• •• • • • •• • ••• ••• • • ••• • • • • • • • • • Sales Offwe: feaiki;/Vplied SVh F1gfi& • • • Scale:NTS I Tolerance:+/•0.25" DwgUnits:In • • • • • • • • • • • • ••• • • • ••• • • p-'IQ,a�c IN 13600Industrial Park Blvd, Minneapolis. MN 55441 rww.DaikinApplied corn Sottwace version: 11.62 Type I X Y I Z I Volts Phase upp an Q Fan 58.00 0.00 1 36.01 1 460 3 Note: Dimensions are measured from the origin point. LEFT ELEVATION VIEW ss VFD u cn Hox c •• ••• •• • • •• RI(1HT Ft EVATION VIEW ••• ••• • • ••• Electrical Connections Unit Tag: RTU-9 Act QS - 10-24 sales O0ce:DaI;:1 Applied LCouttZFbHda • • • / ''D I�- Product: Skyline Air Handler Project Name: Barry University Landon Kitchen R Rkanq n•er: • • • • • • • • a • • 136W Industrial Park Blvd, M,nneaoolls. MN S3441 Model: OAH009GDAM Oct. 24, 2018 ver/Rev: Sheet: 1 of 1 scale: NTS Tolerance: V-0.25" Dwg Units: in www.0aykinAppbed.com Sohware Version: 11.62 ••• • • • ••• • •