Loading...
WS-19-173Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Permit NO.: -01-19-173 Permit Type: Windows/Shutters xfLiclassification: Window/Door Replacement l V Permit Status: Approved Issue Date: 02/04/2019 F Expiration: 08/05/2019 Location Address Parcel Number 1298 NE 97TH ST, Miami Shores, FL 33138 1132050090550 Contacts ANTONIE DOWNS Owner 1298 NE 97 ST, MIAMI SHORES, FL 331382560 AMERICAN STORM PROTECTION Contractor JONATHAN RODRIGUEZ Business: 3052640446 Other:3055130514 InspeInspection Description: INSTALLING 7 IMPACT WINDOWS AND 1 DOOR Valuation: $ 16,707.00 on Requests: c i 49 TotalSq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $10.20 DBPR Fee $2.70 DCA Fee $2.00 Education Surcharge $3.40 Scanning Fee $9.00 Technology Fee $4.50 Windows/Shutters Fee $130.00 Total: $211.80 Payments Date Paid Amt Paid Total Fees $211.80 Credit Card 01/24/2019 $50.00 Credit Card 02/04/2019 $161.80 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and o�iuthermore, I thorize the above named contractor to do the work stated. .w., Authorized Signature: Owner / Applicant / Contractor / Agent Date February 04, 2019 Page 2 of 2 Z f BUILDING Miami Shores Village RECEIVED Building Department JAN242019 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 (� ,� Tel: (305) 795-2204 Fax: (305) 756-8972 _ ` INSPECTION LINE PHONE NUMBER: (305) 762-4949 Loil FBCC 201-4 Master Permit No. W S I ct 1-91 PERMIT APPLICATION 2r�UILDING ❑ ELECTRIC ❑ ROOFING PLUMBING MECHANICAL PUBLIC WORKS JOB ADDRESS: 1 0 t 0 PE l 1_ S Sub Permit No. ❑ REVISION EXTENSION []RENEWAL CHANGE OF CANCELLATION SHOP CONTRACTOR DRAWINGS '? -3 \ Folio/Parcel#: i I` 3� U T,` 0 d 4` 0 S V Is the Building Historically Designated: Yes NO Occupancy Type: Load: Type:( Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Address: d A1qi City: H'1 !nM i S r e � aConstruction J' 1Q n I e— I J n W h Phone#: 63OS0 7� 7933 J 7L State: FL 77 j Zip: J Tenant/Lessee Name: Phone#: Email CONTRACTOR:\ Company Name: ��) � hn �i� 0l��e � n Phone#:(6FL) s /o Address: City: \y�t`^� State: r L ,Zip: Qualifier Name: V (`�\r�r t)�, (' < � V,L Z— Phone#:( o�)1� 4• 8/0 7 State Certification or Registration #: CGG / 5 / 3X7 7 Certificate of Competency #: DESIGNER: Architect/Engineer: one#: Address: City: State: Value of Work for this Permit: $ 1 &X) Square/Linear Footage of Work: Type of Work: ❑ Addition O'Alteration ❑ New ❑ Repair/Replace �%//"1 Description of Work: /I j �r` •�I G�J!n (Cl � 1.4 i f' n � �l y � n tlt Cl Specify color of color thru the: Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ _ Zip: ❑ Demolition CCF $ CO/CC $ DBPR $ Notary $ Double Fee $ Bond $ f� G TOTAL FEE NOW DUE $ V 0 (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. &,1011111 �, OWNER or AGENT The/foregoing instrument was acknowledged before me this lD day of _ G 20J g by AN('fONI E 1�o�unls who is personally known to me or who has produced Signat CONTRACTOR The foregoing instrument was acknowledged before me this 6 day of 20 1 8 by ToNaAwii) ZpJ9 �ho is personally known to as me or who has produced identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: as Sign: Sign:Ce Print: Print: GEC. A L6R MICHAEL MARRESeal: 5e774 Seal: """""'' MICHAEL MARRERO Commission # GG pr o.i e . ires Commission # GG 58774My Commission Exp December 28, 2020 + T My Commission Expires '_Decembar 28, 2020 O u ", APPROVED BY 3/ ! Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) 1/24/2019 Property Search Application - Miami -Dade County C7� OFFICE OF THE PROPERTY APPRAISER .a Summary Report Property Information Folio: 11-3205-009-0550 Property Address: 1298 NE 97 ST Miami Shores, FL 33138-2560 Owner ANTONIE B DOWNS TRS ANTONIE B DOWNS Mailing Address 1298 NE 97 ST MIAMI SHORES, FL 33138 USA PA Primary Zone 1400 SGL FAMILY - 3001-3250 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/3/0 Floors 1 Living Units 1 Actual Area 2,824 Sq.Ft Living Area 1,970 Sq.Ft Adjusted Area 2,334 Sq.Ft Lot Size 8,175 Sq.Ft Year Built 1951 Assessment Information Year 2018 2017 2016 Land Value $294,548 $294,548 $274,141 Building Value $175,050 $162,447 $163,800 XF Value $0 $0 $0 Market Value $469,598 $456,995 $437,941 Assessed Value $248,836 $243,718 $238,706 Benefits Information Benefit Type 2018 2017 2016 Save Our Homes Cap Assessment Reduction $220,762 $213,277 $199,235 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description EARLETON SHORES PB 43-80 LOT 12 BLK 4 LOT SIZE 75.000 X 109 OR 12721-2179 1285 1 Generated On : 1/24/2019 Taxable Value Information 2018 2017 2016 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $19 1,836 $193,718 $188,706 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value $223,836 $218,718 $213,706 City Exemption Value $50,000 $50,000 $50,000 Taxable Value $198,836 $193,718 $188,706 Regional Exemption Value $50,000 $50'000 $50,000 Taxable Value 1 $198,836 $193,718 $188,706 Sales Information Previous Price OR Book- Qualification Description Sale Page 12/19/2011 $100 28022-4715 Corrective, tax or QCD; min consideration 12/01/1985 $127,000 12721-2179 Sales which are qualified 12/01/1979 1 $98,000 10608-1898 1 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version w o d CERTIFICATE OF LIABILITY INSURANCE (MWOONYYY TE r 2/1/2019 ' THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy (ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Insurance Agency, Inc. 100 So 100 South Missouri Avenue Clearwater, FL 33756 CONTACT NAME: PHONE: (800) 277-1620 X 4800 FAX: (727) 797-0704 E-MAIL ADDRESS: INSURERS(S) AFFORDING COVERAGE NAIC# INSURER A: Frank Winston Crum Insurance Company 11600 INSURED FrankCrum UC/F American Storm Protection Corp. dba ASP Windows & Doors Corp 100 South Missouri Avenue Clearwater, FL 33756 INSURER B: INSURER C: INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: 526874 REVISION NUMBER: 1 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REOUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INTR TYPE OF INSURANCE INSRo SWVDR POLICY NUMBER POLICY EFF (MMIDD/YYYY) POLICY EXP &V (MDD/YYYY) LIMITS COMMERCIAL GENERAL LIABILITY CLAIMS MADE ❑ OCCUR AGGREGATE LIMIT APPLIES PER: POLICY ❑ PROJECT ❑ LOC OTHER EACH OOCURENCE $ DAMAGE TO RENTED PREMISES (Ea ocurenoe) $ MED EXP (Any one person) $ PERSONAL & ADV INJURY $ GEN'L GENERAL AGGREGATE $ PRODUCTS-COMP/OP AGG $ a AUTOMOBILE LIABILITY ANY AUTO OWNED AUTOS SCHEDULED ONLY AUTOS HIRED AUTOS NON -OWNED ONLYqAUTO.O.Ly COMBINED SINGLE UNIT (Ea accident) $ BODILY INJURY (Per person) $ BODILY INJURY (Par accident) $ PROPERTY DAMAGE (Per accident) $ a UMBRELLA LIAB EXCESS LIAB OCCUR CLAIMS MADE EACH OCCURENCE $ AGGREGATE $ DED I RETENTION $ I $ A WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y/N ANY PROPRIETOR/PARTNER/EXECUTIVE ❑ OFFICER/MEMBER EXCL (Mandatory In NH) If yes, describe under DESCRIPTION OF OPERATIONS below N/A WC201900000 01 /01 /2019 01 /01 /2020 X PER STATUE OTHER E.L. EACH ACCIDENT $1,000,D00 E.L. DISEASE -EA EMPLOYEE $1,000,000 E.L. DISEASE -POLICY LIMIT $1.000,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) Effective 12/10/2014, coverage is for 100% of the employees of FrankCrum leased to American Storm Protection Corp. dba ASP Windows & Doors Corp (Client) for whom the client is reporting hours to FrankCrum. Coverage is not extended to statutory employees. (Client Ref.: Qualifier: License#: CGC1513274) CERTIFICATE HOLDER CANCELLATION ULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN JRDANCE WITH THE POLICY PROVISIONS. Miami Shores Village Building Department AUTHORIZED REPRESENTATIVE Miami h 2nd AL nue 33138 Miami Shores, FL 33138 01988-2016 ACORD CORPORATION. All rights reserved. ACORD 25 (2016/03) The ACORD name and logo are registered marks of ACORD Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Inspection requirements for: Windows, Doors, Skylights or Fixed Glass (cladding) Permits Upon issuance of permits for the scope of work involving the removal, changing and/or replacement of any type of windows, doors, sidelites, skylights or fixed glass (cladding) the permit holder or qualifier bearing his signature on the permit application shall abide by the requirements of this department and comply with the following statement: Upon obtaining window and/or door permits for the installation of same, it is the responsibility of the permit holder to request window/door framing in -progress inspection, prior to concealment of any horizontal or vertical clip mullion, bucks, shims, etc. Inspector will also verify anchor type, edge distance, embedment and spacing. The purpose for this inspection, is for the verification of conformance with Product Approval (NOA). Acknowled ent: 64+hC4h jZOdrI'q U�z Q alifier/Owner Signature Date Print Name Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 REPLACEMENT OF WINDOWS, DOORS AND SHUTTERS. Permit application must be accompanied by: ❑ Two (2) copies of drawing of the building, showing location of the windows, doors and shutters to be replaces. ❑ Two (2) copies of the Comparison Chart, with all the required information. (NOA approval number, size of each opening, (width and height), opening design pressures, and design pressures for each component taken from the individual NOA, "Notice of Acceptance") ❑ Two (2) copies of State of Florida or Miami Dade County approved NOA for each different components being installed. (Windows, Doors, Mullions, Fixed Glass, shutter) ❑ Florida Building Code -Existing Building, section 706.4 Replacement of windows and doors. The replacement of garage doors, exterior doors, skylight, operative and inoperative windows shall be designed and constructed to comply with Chapter 16 of the Florida Building Code, Building. Exceptions: Opening protection exception for High -Velocity Hurricane Zones. For one -and two-family dwellings constructed under codes prior to September 1, 1994, the replacement of exterior doors with glazing, sliding glass doors, glass patio doors, skylights, and operable and inoperable windows within any 12- month period shall not be required to have opening protection provided the aggregate area of the glazing in the replaced components does not exceed 25 percent of the aggregate area of the glazed openings in the dwelling or dwelling unit. ❑ Every bedroom shall have at least 1 egress opening. The minimum opening size: (20" wide x 24" high) ❑ If Owner is doing the work, include the Owner Builder Disclosure. ❑ Require inspections: Buck (if greater than Ix), Framing and Final. THE ABOVE REQUIREMENTS ARE FOR EXACT RETRO-FIT ONLY. WINDOWS, DOORS AND SHUTTERS MUST BE INSTALLED AS PER PRODUCT APPROVAL. GROUT OR HYDRAULIC CEMENT ARE NOT ALLOWED AS INFILL ON THE PERIMETER OF THE WINDOWS OR DOORS UNLESS SPECIFIED ON THE PRODUCT APPROVAL. Revised on 7/22/2009;11/17/2014 O CWS 8900 Series Sliding Glass Dooi 71 518 x 80 3/8 OX FL11103.1 RECEIVED JAN 2 4 2019 . .... . . . ... .. .. . . . .. .. . . . . . . . . . . . . ....... .... Antoine Downs 1298 NE 97 Street Miami Shores, FL 33138 CWS 89005erie; • • • • • Sliding Glass Door 71 5/8 x 80 3/8 OX X DID X F61i142.1. ... .. • • • • • • • • • CWS 8200 Series • ; • •,Horizontal Roller • • • • • • • • • FL16736.1 • • • 6 • . ... • • (2) 72 3/4 x 49 3/8 w/ 1x3 mull: FL9520.1 X O ' r CWS 8200 Series r Horizontal Roller ' FL16736.1 72 7/8 x 49 1/2 Egress r ' Bedroom •r r ------------------ CWS 8200 Series Horizontal Roller FL16736.1 72314x24314 Wt 14-1��i PERMIT M'am' Shcres Village APPROVED BY DATE ZON'NG DEPT Pt OC; DEFT SI,BJECT i"O CGNTLIMCE WITH ALL FEDERAL STATE ANu CCU Tj f RL L--S AND RECULAT"CNS Door CWS 8100 Series OSingle Hung FL5823.1 (2)37x61314 CWS 8150 Series Picture Window FL13010.1 52 1/4 x 61 3/4 w/ 1x3 mull: FL9502.1 O CWS 8200 Series Horizontal Roller FL16736.1 52 x 37 r WIND LOAD TABLE FOR COMPONENTS AND CLADDING CLIENT: An' trt(m Strry) Prn-�_C461) ADDRESS: I2-ci �K NE 9t Strt-L+ PROJECT: Anfn-ini, Novvns Shorr-s. F-L City State ZIP EXPOSURE " D " I WIND VELOCITY = 175 MPH I ROOF SLOPE > 10 0 Roof Elev. Tributary Area (Sq. Ft) Roof Elev. Tributary Area (Sq. Ft) (ft) 10 15 20 25 30 35 40 45 50 (ft) 10 15 20 25 30 35 • +W 45 50 + 48.6 47.3 - 46.4 45.7 45.1 44.6 44.2 -- . 43.8 -........_..- 43.5 + 48.6 47.3 46.4 ,#45.7 •45.1 - 44.6- 4q�2 - -... 43.8 - - - 430% .....-.. -- - 52.7 51.4 50.5 49.8 49.2 48.8 48.3 48.0 47.6 - 65.1 62.5 60.7 99.03 96.1 57l2 566 55.6 541 17 + 49.5 48.2 47.3 46.6 46.0 45.5 45.1 44.7 44.4 17 + 49.5 48.2 47.3 4I6.0 W.0 4505 " 45.1 44.7 4A.4 53.7 52.41 51.5 50.8 50.2 49.7 49.3 1 4119 148.6 66.3 1 63.7 1 61.9 0M.14 "99.3 58.3 37.41 56.6 56.0 20 + 51.0 49.6 48.7 47.9 47.3 46.8 46.4 46.0 45.6 20 + 51.0 49.6 48.7 499' �47.3 46P 4&4 46.0 45.6 A - 55.3 53.9 53.0 52-2 51.6 5L1 50.7 50:3 49.9 A - 68.2 65.5 1 63.6 ftV•61.0 5" ".0 58.3 57.d 22 + 51.9 50.5 49.6 48.8 48.2 47.7 47.2 4.8 46.5 4) 22 51.9 49.6 *4 •l2 4-7.7 4T2 46.8 _ 4&9a 56.3 54.9 54.0 53.2 52.6 52.1 51.6 512 50.9 69.5 66.8 64.8 '99.30 062.1 6L'0' 80.1 59.3 58.d - 25.3 + 530 51.9 50.9 50.1 49.5 49.0 48.5 ',48.1 47.7 Ln 0 25 + 53.3 519 50.9 • • .5 49.0 48.5 48.1 47.7 0 U. a rn30 i (A i 57.8 56.4 55.4 1 543 54.0 5151 53.0 52,6 ' 52.3 �0 W 4A "' i 'A v 71.4 68.6 66.6 %5.0 03.8 6L0 60.L 28 + 54.3 52.8 51.8 5LO 50.4 49.8 49.4 49.0 48.6 28 + 54.3 52.8 51.8 1.0 *5p.4 49!8 49.4 49.0 58.9 57.4 56.4 55.6 55.0 54.4 54.0 53.6 53.2 - 72.7 69.8 67.8 6" 04.9 63t8 8? 62-0 61.3 + - 54.7 _53.3 52.3 5L5 50.8 50.3 49.8 49.4 54,0 49.0 30 + 54.7 -- 73.3 53.3 70.4 52.3 ---- 68.3 51.5 66.81 50.8 50.3 W.8 49.4 49.0 59.4 57,9 --.._........ 56.9 56.1 --- 55.5 - 54.9 54.4 53.6 65.5 64.4 63.4 62.6 61.8 35 + 56.1 54.7 53.6 52.8 52.1 51.6 51.1 50.7 50.3 + 56.1 54.7 53.6 52.8 52.1 51.6 51.1 50.7 50.3 60.9 59.4 58.4 57.6 56.9 56.3 55.8 55.4 55.0 75.2 72.2 70.1 68.5 67.2 66.0 65.1 64.2 63.4 y 0 N M qj 0 N 1+1 37.6 56.0 55.0 54.1 53.5 52.9 52.4 51.9 51.5 + 37.6 56.0 55.0 54.1 53.5 52.9 52.4 51.9 51.5 62.4 60.9 59.8 59.0 58.3 57.8 57.3 56.8 56.4 - 77.1 74.0 71.9 70.2 68.9 67.7 66.7 65.8 65.0 45 + 59.0 - 57.4 56.3 55.5 60.5 54.8 54.2 - 59.2 53.7 58.7 53.2 - 5&2 52.8 -- 57.8 45 + 59.0 57.4 56.3 55.5 54.8 54.2 53.7 53.2 52.8 - - - 64.0 62.4 61.3 59.8 - -- 79.0 75.9 73.7 71.9 70.5 69.4 68.3 67.4 -- 66.6 50 + 59.91 5&3 1 57.2 56.41 55.61 55.0 54.5 54.1 53.7 50 + 59.9 58.3 57.2 56.4 55.6 55.0 54.5 54.1 53.7 - 65.0 63.41 62.3 6L4 60.7 60.1 59.6 59.1 58.7 - 80.2 77.1 74.8 73.1 7L7 70.5 69.4 68.5 67.7 55 + 60'9 59.3 58.1 57.2 56.5 55.9 55.4 54.9 54.5 55 + 60.9 59.3 58.1 57.2 56.5 55.9 55.4 54.9 54.5 - 66.0 64.4 63.3 62.4 61.7 6L1 60.5 60.1 59.7 81.5 7&3 76.0 74.3 72.8 71.6 70.5 69.6 68.8 + 61.8 67.0 60.2 65.4 59.0 58.1 63.4 57.4 62.6 56.8 62,0 56.2 51.5 55$ 6L0 55.3 60.6 60 + 61.8 60.2 59.0 5&1 57.4 56.8 56.2 55.8' 55.3 64.3 82.8 79.5 77.2 75.4 73.9 72.7 71.6 1 70.7 1 69.8 GENERAL NOTES FIGURE 1 D-10% OF LEAST HORIZONTAL DIMENSION 1. TABLES VALID ONLY FOR BUILDINGS OF MEAN ROOF HEIGHT 60 FT. OR LESS. ELEVATION "H" FOR SLOPED ROOFS IS THE MEAN ROOF HEIGHT. ZONE 4ED 2. ROOF ELEVATION "H", IS DETERMINED ZONE 5f BY USING FIGURE 1 AS REFERENCE. 3. IDENTIFY ZONE OF COMPONENT PER FIGURE 1. H 4. POSITIVE AND NEGATIVE LOADS ARE TAKEN AT MEAN I D� ROOF HEAIGHT AND APPLY TO ALL FLOORS. D DccN Yam°` 5. TABLE ABOVE SHOWS MAXIMUM DESIGN LOAD FOR SHOWN BUILDING HEIGHT IN END ZONE. 6. THIS DOCUMENT IS NOT VALID WITHOUT THE EMBOSSED SEAL OF AN ENGINEER EMPLOYED BY AL-FAROOQ CORPORATION. 7. NO PORTION OF THIS DOCUMENT MAY BE USED OR REPRODUCED IN ANY MANNER, EXCEPT FOR THE PORTION OF ASCE 7-10 SET FORTH HEREIN. 8. ALL LOADS ARE CALCULATED AS PER ASCE 7-10 AND LATEST FBC 2017 STANDARDS date:l°-02-13 1 REVISIONS: AL-FAROOQ CORPORATION drown by. M.F. no. date by description ENGINEERS & PRODUCT DEVELOPMENT checked by: H.M. 9360 Sunset Dr. Suite TEL. (305) 264-8100 DWG NO. 1 220 MIAMI, FL 33173 FAX. (305) 262-6978 SHEET 1 OF 1 ii►11,:� i JKVAD AHMAD FLA P.E. / 70592; EB CAN. 35M • 71 f KP ^^ BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search p r Product Approval USER: Public User i Yn Product ADproyal Menu > Product or Application Search > Application List > Application Detail FL # FL9520-R7 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Custom Window Systems Inc. 1900 SW 44th Avenue Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Kevin Pine kpine@cws.cc Jay Lathrop 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Arturo Monteverde 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext221 amonteverde@cws.cc Windows Mullions Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Q Evaluation Report - Hardcopy Received Lucas A. Turner PE-58201 Keystone Certifications, Inc. 07/21/2020 Steven M. Urich, PE 0 Validation Checklist - Hardcopy Received FL9 20_R7_COI_EvalReport836B.pdf Standard Year AAMA 450-10 2010 ASTM E1886-05 2005 ASTM E1996-09 2009 PA TAS 201/202/203 1994 A r Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Florida Licensed Professional Engineer or Architect FL9520_R7_EE uiv_FL9520 Eauivalency_pdf Method 1 Option D •••• Date Submitted 09/29/2017 • • • • •••• •••••• Date Validated 10/02/2017 • • ..•. � • • Date Pending FBC Approval 10/05/2017 • • • • • • : • • • • •..;. Date Approved 12/12/2017 • 900000 • • • •••••• Products •• •.• •�•. ••'• ••• ummary of •`� FL # Model, Number or Name Description •' • • • • • • • • • • • • • 9520.1 3" Alum. Tube Mullion 3" Alum. Tube Mullion, gorizbn=al & Vertical, Fin & FI.arQg • applications. (IMPACT) • • • • • • Limits of Use Installation Instructions e • • • • Approved for use in HVHZ: Yes FL9520 R7T CWS-836B.pdf �.;.. • _ Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile Impact; See Installation Instructions FL9520 R7 AE EvalReoort836B.pdf and Evaluation Report for complete list of Limitations and Created by Independent Third Party: Yes Conditions of Use. 9520.2 4" Alum. Tube Mullion 4" Alum. Tube Mullion, Horizontal & Vertical, Fin & Flange applications. (IMPACT) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL9520_R7 II_CWS-837B.pdf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile Impact; See Installation Instructions FL9520_R7_AE EvalReport837B.pddf and Evaluation Report for complete list of Limitations and Created by Independent Third Party: Yes Conditions of Use. 9520.3 5 1/2" Alum. Tube Mullion 5 1/2" Alum. Tube Mullion, Horizontal & Vertical, Fin & Flange applications. (IMPACT) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL9520_97_II_CWS-838B.122f Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile Impact; See Installation Instructions FL9520_R7_AE_EvalReport838B.pdf and Evaluation Report for complete list of Limitations and Created by Independent Third Party: Yes Conditions of Use. Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copvrioht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® W in .I.c M Credit Card Safe . . .... ...... .. . . . . ...... ...... . .....• .... . .• ....• ...... .... ..... .. .. .... ...... . . . . ...... 00*0 ANCHOR CLIP —• 3" PVC MULL BAR - LARGE MISSILE IMPACT SHOWN w/DIFFERENT OPTIONS • v • qq NNu v • v j • I I 10 G F E D ANCHOR CLIP) 10 9 9 EXAMPLE HORIZ/.VERT. MULLION FOR SECTION VIEW ONLY TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS...............1 DPCHARTS.................................................2-3 BOM & EXTRUSIONS. .................................... 4 EXTRUSIONS.................................................5 SECTION VIEWS ......................................... CONFIGURATIONS & ANCHOR NOTES....6.8 INSTALLATION DETAILS ..........................9-10 —ANCHOR CLIP GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH VWJAIJ(yll//UUUj//'y' WINDOW SYSTEMS L� THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND IS RATED FOR WIND ZONE 4 MISSILE LEVEL 1900 SW 44TH AVE. 1900 S44THFLORIDA E. ALA, 34474 D IMPACT USE AS DEFINED IN ASTM E 1996 PER THE FBC. W Cc 2. CONFIGURATIONS (SEE SHEETS 2-3): VERTICAL OR HORIZONTAL. 3. SEE MULLION CHARTS FOR MAX. DESIGN PRESSURES AND LENGTH. 3" PVC (REFER TO SHEETS 2-3) MULL BAR 4. ANCHORAGE: THE 33 1/3 % STRESS INCREASE HAS NOT BEEN USED IN THE IMPACT DESIGN OF THIS PRODUCT. SEE SHEETS 9-10 FOR ANCHOR DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD.ANCHOR CALCULATIONS. 5. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED. H z 3 az� 0 w p Cn w O 6. DESIGN PRESSURE OF MULLED UNITS SHALL BE CONTROLLED BY THE LESSER w 0 z O z Y0E3m DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNITS. LL am 3 F w z i­- �: = Z i zSmQ¢wpp 7. DESIGN PRESSURES AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT 0 0 ~ O U ¢ = 1- m Z Z Z ~ a APPLY ONLY TO THE MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE - Co 0 O E) APPROVAL. z O V �/j U- �— MOOLLZ 8. RESPONSIBILITY OF SELECTING FENESTRATION PRODUCTS TO MEET ANY ¢ i ¢ 0 w z - APPLICABLE LOCAL LAWS, BUILDING CODES, ORDINANCES OR OTHER SAFTEY U REQUBUILDIREMENTSRESTS SOLEY WITHTHE ARCHITECT, ENGINEER OF RECORD, w Z _ a) 0 w U) w OWNER CONTRACTOR. oo _ a ILX wP0 9. SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS a a w 3 w cr DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFACTURED BY CUSTOM WINDOW SYSTEMS, INC. AND MUST BE MADE OUT OF VINYL PVC OR EXTRUDED ALUMINUM. 10 VERTICAL MULLED UNITS MAY BE MULLED FINITELY AS LONG AS THE SINGLE PG ENS UNIT WIDTH AND HEIGHT ARE NOT EXCEEDEDEAND MULLIONS ARE ANCHORED AS ��` SHOWN HERE IN. :`J •ytn� z-: No 58201 :1) 11. HORIZONTAL MULLION SHALL EXTEND THE ENTIRE WIDTH OF THE MULLED UNIT. *: k VERTICAL MULLION IS USED TO MULL SIDE BY SIDE UNITS TOGETHER. ANCHOR CLIP O I O x L X 4 ANCHOR CLIP • IP% STATE OF Lucas Turner 2017-09-28 Z 07:12+20:00 9/26/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. • • • • • • • • • • • • NORTH PORT, FL 34288 • • • • • • • • • PH.941-380-1574 • • • • • • • • • • • SHEET DESCRIPTION: • • • • • • • • • • • • GENERAL NOTES AND ELEVATIONS •• ••• • •• • EXAMPLE VERTICAL MULLION FOR • • • PVC WINDOWS FOR SECTION VIEWS ONLY • • • i • • • • • • • • 0 • AIDE 09/27/12 • • • • • • • DWG N: REV.' • • • • • i i CWS-836 B • • • • SCALE: SHEET 1:25 1 OF 10 ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • Ipact PVC 3" Mullion H-1758, with 1522 clips using four (4) #10 Screws into WOOD or METAL or 3/16" ITW Tapcons or or WOOD per each end of mullion. HOLLOW or GROUT -FILLED BLOCK require 1 /4" ELCO ULTRACONS. OPENING SIZE (in.) i7 1 63 1 69 1 75 3/8 1 81 1 87 1 93 1 99 1 107 3/8 1 114 1 120 37 80.0 80.0 1 80.0 80.0 80.0 80.0 80.0 80.0 1 80.0 80.0 1 80.0 80.0 1 80.0 80.0 1 80.0 80.0 1 80.0 80.0 c 42 314 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 48 3/4 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 w 57 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 -+ 63 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 78.9 76.6 74.8 72.5 65.0 65.0 65 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 68 1 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 63.5 72 65.0 65.0 65.0 65.0 65.0 65.0 65.0 64.9 61.7 59.1 56.9 53.7 DP CHART IS FOR: NON -INTERSECTED IMPACT 3" MULLION 1758, HORIZONTAL OR VERTICAL, USING (PER END): 1522 CLIPS - (4) #10 SCREWS INTO WOOD or METAL - (4) 3/16" ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD -(4) 1/4" ELCO ULTRACONS INTO HOLLOW or GROUT -FILLED BLOCK ---------------------------------------------------------------------- Design Pressure Chan (PSF) for NON -INTERSECTED Impact PVC 3" Mullion H-1758, with 1776 clips with six (6) #10 Screws into WOOD or METAL or 3/16" ITW Tapcons or ELCO ULTRACONS into SOLID CONCRETE or WOOD per each end of mullion. HOLLOW or GROUT -FILLED BLOCK require 1 /4" ELCO ULTRACONS. OPENING SIZE (in.) 39 1 45 51 57 63 69 75 3/8 81 67 93 99 107 W8 114 120 126 132 138 145 318 37 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 c 42 314 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 = 48 3/4 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 C7 53 1/8 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 w 57 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65.0 63 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 65.0 65.0 65 65.0 65.6 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 68 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 65.0 1 72 1 65.0 1 65.0 1 65.0 1 65.0 1 65.0 1 65.0 1 65.0 1 64.9 DP CHART IS FOR: NON -INTERSECTED IMPACT 3" MULLION 1758, HORIZONTAL OR VERTICAL, USING (PER END) 1776 CLIPS - (6) #10 SCREWS INTO WOOD or METAL - (6) 3/16" ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD -(6) 1/4" ELCO ULTRACONS INTO HOLLOW or GROUT -FILLED BLOCK TWIN 0 z J J L I �1 OPENING SIZE � OPENING SIZE I TRIPLE VERTICAL MULLION zz W J TRANSOM OVER TWIN VERTICAL MULLION OPENING TRANSOM OVER TRIPLE VERTICAL MULLION T- 0 z W J J E L II OPENINGSIZEI- NOTES: 1. THE MULL BAR IN FOCUS FOR ANY GIVEN CONFIGURATION IS SHOWN IN BOLD. 2. AN INTERSECTED MULL BAR HAS OTHER MULL BAR(S) ATTACHED TO IT (SHOWN IN DASHES) THROUGH THE USE OF MULL BAR CLIPS. AN INTERSECTED MULL BAR WILL ALWAYS BE ATTACHED TO THE SUBSTRATE AT BOTH ENDS. 3. NON -INTERSECTED MULL BARS CAN BE ATTACHED • • • •TA VE SUBSTRATE AID OT4IJR MULL BARS. TWIN • •• T4WIPLG • • ••• • TWNTARLIPLE MU HORIZONTAL MULLION • HOF�ZOr�AL�ULI�ON• • • I-PRIZONiAL MULLgN 0 see W ' i N OPENING a)SIZE t* z •• • • ••• • • • • • • w • z a • i • • • • • • • • L• 7 • MULL LENGTH ---- I T I-- MULL LENGTH MULL LENGTH • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • v WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 3" PVC MULL BAR IMPACT a i 3 ¢z� F OWO aWOO ui Lu z0Z�O=Z~ u_ �w3z�3Zx z zX2<mW00 O Oro a=F¢ O 0(ni-ZaPtocL Q OZOOZO 0 F- '200LLU faOw1=FOz 00 -Lu z� ¢ z10w�Ow0~ 0 0 w�0 am,i a 9/26/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SHEET DESCRIPTION: DP CHARTS NON -INTERSECTED AIDE 09/27/12 VG#: REV.: CWS-836 B ALE: SHEET 1:1 2OF10 pressure Chart (PSF) for INTERSECTED Impact PVC 3" Mullion H-1758, with 1522 clips using four (4) #10 Screws into WOOD or METAL or 3/16" rrW Tapcons into SOLID CONCRETE or WOOD, or 1776 clips with six (6) #10 Screws into WOOD or METAL or 3/16" ITW Tapcons into SOLID CONCRETE or WOOD per each end of mullion. HOLLOW or GROUT -FILLED BLOCK require 1 /4" ELCO ULTRACONS. OPENING SIZE (in.) 39 1 45 51 57 63 69 75 3/8 81 87 93 99 110 3/8 114 120 126 132 138 145 318 97 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 c 42 314 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 48 314 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 O 531/8 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 57 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 48.1 w 63 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 49.4 47.3 68 50.0 50.0 50.0 50.0 50.0 1 50.0 50.0 50.0 50.0 50.0 50.0 1 50.0 49.8 47.6 M 72 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0 45.4 44.0 75.375 1 50.0 1 50.0 1 50.0 1 50.0 1 50.0 1 50.0 1 50.0 1 50.0 1 50.0 1 46.8 1 44.0 1 40.0 DP CHART IS FOR: INTERSECTED IMPACT 3" MULLION 1758, HORIZONTAL OR VERTICAL, USING EITHER (PER END) 1522 CLIPS - (4) #10 SCREWS INTO WOOD or METAL - (4) 3/16" ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD -(4) 1/4" ELCO ULTRACONS INTO HOLLOW or GROUT -FILLED BLOCK 1767 CLIPS - (6) #10 SCREWS INTO WOOD or METAL (6) 3/16" ITW TAPCONS or ELCO ULTRACONS INTO SOLID CONCRETE or WOOD (6) 1/4" ELCO ULTRACONS INTO HOLLOW or GROUT -FILLED BLOCK TWIN/rRIPLE HORIZONTAL MULLION VERTICAL MULLION r w SINGLET to i w z z TWIN a OR I O ITRIPLEI _ _ _ _ _ UNITS LI LII iBELOW MULL LENGTH - I I (_OPENING SIZE WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 3" PVC MULL BAR IMPACT a z az3 ow0 Qwoo o zvOiz>o�3m U_ Z F w Z F� 2_ ZX2<mwoo O Oro a=r O(n�ZaHv)a Q OZ0(nZ0UfA F-u 20 u-z r °C��»30W w O�a[(nowinw Z T'L 0 _j a wr¢ a-= L r a ¢3a 9/26/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. • • 000 • • • • • • • NORTH PORT, FL 34288 • • • • • • • • • PH.941-380-1574 • • • • • • • • • • • SHEET DESCRIPTION. • • • "WTES► • • • • • • DP CHART 1. THE MULL BAR IN FOCUS FOR ANY GIVEN INTERSECTED MULLS CONFIGURATION IS SHOWN IN BOLD. 2. AN INTERSECTED MULL BAR HAS OTHER MULL DRAWN BY: DATE • • • • • BAfi(S) AWA3HED TOIi l6HOWN IN DASHES) ADE 09/27/12 • • T GH TI It USE OFMMULIBA CLIPS. AN •• • ii •• • • • •IN E (:6TD M L BSI,+ WI L WAYS BE DWG#: REV.' • • • • ATTAQHER TpTHE SUWVR4TEoNT BOTH ENDS. CWS-836 B • • 3. NON-Il4TER*ECTED MULL BARS CAN BE ATTACHED 9cALE: SHEET TO THE SUBSTRATE AND OTHER MULL BARS. 1;1 3 OF ••• • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • ••• • • PART # DESCRIPTION H-1758 1 3/8" x 3" MULLION TU #10 OR #12 HEX WASH #10 x 1 1/2', PANHEAD #10 FLAT WASHER S-1897 MULLION CLIP SEALANT S-1895 DRIP CAP S-1896 FLANGE ADAPTER S-6018 MULLION INTERIOR CO P-3486 MULL BAR CAP 1522-013 3" SLOTTED NEW CON 1522-006 3" SLOTTED T-CLIP USE WOOD SCREW SIZE (#10 OR #12), SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENT 7/16" 1— 1 3/4" 11 1/16" MULLION INTERIOR COVER S-6018 F-1 3/8" I 1 2131/16" 1/8" L 3" MULLBAR H-1758 1/2" T I} 1/2" 1 1I/4" 10 11/1 9 L 1116" 1/16" DRIP CAP S-1895 FLANGE ADAPTER S-1896 I-- TOP VIEW 21/16"- 7 1 3/16" 118" MULLION CLIP 8-1897 U � \ A isv SCORE, BEND AND BREAK i TO REMOVE FIN FOR FRAME ATTACHEMENT TO MULL BAR DETAIL A TYR FIN FRAME 3:1 NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. LINE ITEMS NOT USED: 5-6, 12 IN O 1/4" (fYl F —1 3/4" —+-1 3/8" —I 14 2 1/4" L 4 7/8" F-1522-013 NEW CONSTRUCTION / FIN INSTALLATION FRAME TYPE OPENING "T" MULLBAR CLIP (F-1522-XXX) FLANGE NEW F-1522-013 RETRO F-1522-006 FIN NEW F-1522-013 RETRO F-1522-013 BOX NEW NOT RECOMMENDED RETRO F-1522-006 2 F-1767-001 F-1767-001 F-1767-004(L&R) F-1767-004(L&R) F-1767-001 F-1767-001 15 2 3/16" F-- 4 7/8" �i F-1522-006 • • • • • • • 4RETW 14FLANOF* CLIP • •• • • • • ••• • •• ••• • ••• •s• • • • • • • • • • • • • • • • • • • • ••• • • • • ••• • • • • • • • • • • • • • • ••• • • • ••• • • WINDOW SYSTEMS 19DO SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 3" PVC MULL BAR IMPACT a z 3 az3 P ow0 WwOo w zoz ¢�?W o Qw�Y0m3:5 u- F w zi--32= z zxia¢woo O OHO ¢_�-¢ U 0co F-za-Hind In z F--U-moo LL z cc ir Ill �0� rnW(r(n o wen �aOFr z a0m0w~¢—: I, 'war 9/26/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH.941-380-1574 BOM AND EXTRUSIONS I ADE 09/27/12 VG #: REV.: CWS-836 B :ALE: SHEET 1:2 4 OF 10 1 "L" ANGLE 3" MULL CLIP, FIN (LEFT) F-1767-004L OUTSIDE "L" ANGLE 3" MULL CLIP, FIN (RIGHT) F-1767-004R FRAME TYPE OPENING "T" MULLBAR CLIP (F-1522-XXX) FLANGE NEW F-1522-013 RETRO F-1522-006 FIN NEW F-1522-013 RETRO F-1522-013 BOX NEW NOT RECOMMENDED RETRO F-1522-006 2 3/4' 2 1 /4" 1 5/8" (2 3/41 3/8" (2X) F-1767-001 WINDOW SYSTEMS L_ F-1767-001 1900 SW 44TH AVE. F-1767-004(L&R) OCALA. FLORIDA 34474 F-1767-004(L&R) WWW CWS.CC F-1767-001 F-1767-001 3" PVC MULL BAR IMPACT < z 3: ¢Z3 F- owo rnWo0 k w z O z ¢Q_ z H u- FW�ZO3�m2 z Zxi¢mWoo Oro ¢=Fm U1n�ZarmD- ¢ -zoozo 0 <-LLgUOoU ¢ f<O- OZ W 27/16' ¢ Z�W O�fgF a O WFz-m mmmm a o ¢3:a 7/16" THRU(TYP)1/4' THRU(TYP) 1/2" OUTSIDE 6 7/8" "L" ANGLE 3" STANDARD MULL CLIP - F-1767-001 •• ••• • • • • • •• •• ••• •• • • • •• •• ••• • ••• ••• • •• • ••• • • • • • • • • • • • • • • • • • •• • • • •• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • X` 9/26/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 EXTRUSIONS IAWN BY: DATE: AIDE 09/27/12 VG f: REV.: CWS-836 B 'ALE: SHEET 1:2 SOF10 SEAL BEHIND FU PRIOR TO ATTAC TO MULLION SEAL BEHIND FLA PRIOR TO ATTACI TO MULLION FIN MUST BE REMOVE WHERE WINDOV CONNECT TO MU IJIM4 APPLY SEALANT ALONG FL LENGTH OF WINDOW FRAI GROOVE PRIOR TO ATTACHII cob A HORIZONTAL MULL BAR SECTION I A�HORIZONTAL MULL BAR SECTION I A VERTICALMORIZ NTAL MULL BAR SECTION s FLANGE FRAME WINDOW 6 FIN FRAME WINDOW a BOX FRAME WINDOW I I I I ---I----------------------- 1-------------------------- I I i t 1 2 APPLY SEALANT ALONG FULL 11 1 2 I LENGTH OF MULLBAR GROOVE PRIOR TO ATTACHING DRIP ADAPTOR I Q I (l OFIN MUST BE REMOVED 1 WHERE WINDOWS CONNECT TO MULL 9 0 i DETAIL A I I SEAL BEHIND FLANGE 10 (SEE DETAIL B) SEAL BEHIND FLANGE 10 (SEE DETAIL B) PRIOR TO ATTACHING 1 APPLY SEALANT ALONG FULL PRIOR TO ATTACHING TO MULLION ALA QQ TO MULLION LPR OR Tj1'drAGFQaN • • • • • �BIVERT'CAL MULL BAR SECTION VERTICAL MULL BAR SECTION • • • D = 1481. • 6 FLANGE FRAME WINDOW 6 FIN FRAME WINDOW • • • r• I I L I I • • • • • • • • • • Df'TAIL B • • I I ••• • • • • ••• • • • • • • • • • • • • • • • • • • • • ••• • • • ••• • • fflWINDOW SYSTEMS 19DO SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 3" PVC MULL BAR IMPACT Q Z a23 F= 0w0 awoo w ZOZ ¢k?F- LL FW ZH3:�2 Z ZXm<mwpo O OF o d a=F¢ zooz - LLmo°LLZ �QoFF-Mo- 0 03ow IL LLD 0 -1 0 wHo a-m a a ¢3a z:�-' 9/26/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SECTION VIEWS MULLS AIDE 1 09/27/12 CWS-836 B ALE' SHEET 1.2 6OF10 CD CD D CD A l� ����.'. CD I I nrlr ;�r o i 1L r �i fl I�JI A --' b TOP VIEW FIN FRAME 5" MULLBAR (H-1760) (SEE SEPARATE APPROVAL FOR APPROPRIATE DP CHARTS) SECTION VIEW A -A 4" MULLBAR (H-1759) (SEE SEPARATE APPROVAL FOR APPROPRIATE DP CHARTS) SEE NOTE 1 7 11/16" MAX. EDGE DISTANCE SEE NOTE 1 1]_/16" MAX. EDGE DISTANCE 7 � 1 19 SEE NOTES 1 & 2 1 19 SEE NOTES 1 & 2 (1 EA./CLIP) (1 EA./CLIP) SEE NOTE 4 SEE NOTE 4 rG"� 5" HN RIZ. TO 3" VERT. MULLBAR SECTION 4 HOG TO 3" VERT. MULLBAR SECTION SEE NOTI DISTANCE WINDOW SYSTEMS L-2! 1 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 3" PVC MULL BAR IMPACT ¢ F ? az3 O W O Q wr p W o ZOz �CZH aN_rox3m_ IL z I-Lu 3gx zx�a¢WOO ou aax-nF¢ OnF o z ZA�wOVajZ8UZ¢�-LLOFOO r po�i�3o2 zcow��JlnF- a IL a =~x W 3:ww F a x 0- 1 19 SEE NOTES 1 & 2 (1 EA./CLIP) SEE NOTE 1@ 9/26/2017 %C1 3" HORIZ. T03" VERT. MULLBAR SECTION LUCAS A. TURNER, P.E. 7WINUUW FL PE # 58201 1239 JABARA AVE. • • • • • • • • • • • • • • NOTES: • • • • • • • • • • • • • 1. SLIDE CLIP INTa LOCAMSN AND *ECYRE@NIT;dMS 1j (OTY 1) AND 20 (OTY 1), AS SHOWN ABOVE• • • • • • • • • • • • • • • • • • • • NORTH PORT, FL 34288 PH.941-380-1574 SHEET DESCRIPTION: SECTION VIEWS 2. PRE -DRILLED HOLES (THRU HN CLIP 1897), BY THE INSTALLER, MAY BE LOCATED AS NEEDED WHILE MAINTAINING A MINIMUM CLIP EDGE DISTANCE MULL INTERSECTIONS OF 9/32' AND A MINIMUM CENTER TO CENTER SPACING OF 1/2". DRAWN BY DATE: • • • • • • • 3. THE ABOVE SECTpNS APPL,� TO ALLI�IJ�LBAR- LL AIR CONNECTIONS, REGAR 1<SS OF ORIENTAT" ".e., F 'jONTAL R VE TI L . THE FULL LENGTH MULL MVST�E THt SAME DIPTM, OR GREATER, T N T E IlTERSECTING MULL.0. • • •00 4. INTERIOR MULL AISCHOR ATTACIOIMEN1•SCREW THRU VERTICAL MULL INTO MULL CLIP. PRE -DRILL PILOT HOLE THRU ALL MATERIAL. ADE 09/27/12 DWG t: CWS-836 REV.: B scALE: 1 :2 SHEET 7 OF 1 O • • • • • • • • • • TWIN VERTICAL MULLION OPENING SIZE TWIN TT HORIZONTAL MULLION I co w 0 L�-- MULL LENGTH -- NOTES: TRIPLE VERTICAL MULLION OPENING SIZE TRIPLE HORIZONTAL MULLION n 7 z L L i 7 MULL LENGTH TRANSOM OVER TWIN VERTICAL MULLION TRANSOM OVER TRIPLE VERTICAL MULLION nPFNINt: S17F TWIN/TRIPLE TWIN/TRIPLE VERTICAL MULLION HORIZONTAL MULLION T OPENING SIZE z L J s L - -,� I OPENING SIZE MULL LENGTH -� NOTES: 1. THE MULL BAR IN FOCUS FOR ANY GIVEN CONFIGURATION IS SHOWN IN BOLD. 2. AN INTERSECTED MULL BAR HAS OTHER MULL BAR(S) ATTACHED TO IT (SHOWN IN DASHES) THROUGH THE USE OF MULL BAR CLIPS. AN INTERSECTED MULL BAR WILL ALWAYS BE ATTACHED TO THE SUBSTRATE AT BOTH ENDS. 3. NON -INTERSECTED MULL BARS CAN BE ATTACHED TO THE SUBSTRATE AND OTHER MULL BARS. IIr HORIZONTAL MULLION I w N fp ISINGLE1 i z TWIN W OR 0 ITRIPLE1 UNITS BELOW I_— MULL LENGTH --I WINDOW SYSTEMS 0 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 3" PVC MULL BAR IMPACT Q ? <Z3 P 0WO aWod w zpz ¢kzw W F-W�ZF-3�= Z Z2m<QWOO OHO <21-Q U to F-ZQ- Etna z - =)0 Q- < i_— 'mo LLZ <3 W-2o_ f <UTFHU~Ztn L1 OO .LL t}i10 W(nW IL ?=Wa a0[O�td m _~, W 3 W w a r a a:a 1. AT MULLION LOCATION, ATTACH WINDOW UNIT(S) TO MULLBAR THRU FRAME AS SPECIFIED IN WINDOW UNIT APPROVAL DOCUMENTS. IF ALUMINUM ATTACHMENT IS NOT SPECIFIED IN THE WINDOW UNIT APPROVAL z� DOCUMENTS, FOLLOW THE ANCHOR SPACING AS INDICATED IN THE WINDOW APPROVAL FOR ATTACHMENT TO WOOD SUBSTRATE, USING A HEX WASHER HEAD TEK SCREW OF THE SAME SIZE (#10 OR #12) AS THE WOOD SCREW INDICATED IN THE WINDOW APPROVAL. TEK SCREWS SHALL BE LONG ENOUGH TO ENSURE THREE (3) THREADS OF PENETRATION BEYOND THE INSIDE WALL OF MULLBAR. 9/26/2017 2. MULL CLIP INSTALLATION ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 9, LUCAS A. TURNER, P.E. 3. ALL MULL CLIP INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. • • • • •: : : • • • �:p : • • • 4. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED INS T 0IT S EIlGT�S LESS THAN THE • � � I! ri 39 A # RA Al 123H JABARA AVE. NORTH PORT, FL 34288 PH.941-380-1574 • • MINIMUM SPECIFIED IN TABLE 1, SHEET 9. • 0 • • : • • • • t • • • • • 5. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE - 1 X BUCKS SHEET DESCRIPTION: CONFIGURATIONS AND ARE OPTIONAL. ANCHORAGE NOTES 6. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED AS INDICATED BY THE PRE -DRILLED HOLES AS SHOWN IN THE CLIP LAYOUT 6I1 SIY2EtS 4-5. • 000 000 • 00 7. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND IWSTA • ED TO ICSF�R WIND LOADS TO THE STRUCTURE. • • DRAWN BY: DATE, DWG l: REV.: • • SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLEt, SHEET 9. CONCRETE AND MASONRY SUBSTRATES MAY HOT BG GRACK D. • • • •• • • • 8. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENT!? FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS), FMA/AAMAANDMA 300(EXTERIOR DOORS) CWS-836 B SCALE: 1:1 SHEET 8 OF 10 ••• • • • • ••• • ••• • • • •• •• RETRO FIT MULL BAR CLIP SEALANT ALONG OUTSIDE EXPOSED EDGE BY INSTALLER PERIMETER SEALANT BYINSTALLER INSIDE AND OUT MULL BAR INSTALLATION ANCHOR SEE TABLE 1 ADD STRUCTURAL ELEMENTS AS REQ'D TO MAKE LEVEL FOR MULL BAR MIN. EMBEDI SEE TABLE 1 SUBSTRATE BY OTHERS �L \ \ SEE TABLE 1 I\ MIN. EDGE DIST. SEE TABLE 1 /_ u ,VERTICAL SECTION 9 TYPICAL FLANGE (RETRO FIT) ANCHORAGE HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION TABLE 1: APPROVED MULL CLIP INSTALLATION FASTENERS SUBSTRATETYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. CONCRETE (2.0 KSI MIN.) 3/16" ITW TAPCON 1" 3" CONCRETE (2.85 KSI MIN.) 1 1 1 HOLLOW or - I 7-90 1 4 1-1 4 2-1 2 2X MIN. SOUTHERN PINE (G=0.55) 3/16" ITW TAPCON 1-3/8" 7/8" OR ELCO ULTRACON 2X MIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-3/8" 7/8" 16 GAUGE (0.060") MIN. STEEL STUD #10-16 HILTI KWIK-FLEXOR ITW FULL THREAD (33 KSI YIELD MIN) TEKS SELF -DRILLING SCREW THRU 0.060" 7/16" 1/8" ALUM. (6063-T5 MIN.) OR #10 GRADE 5 SELF -TAPPING / FULL THREAD 1/8" STEEL (33 KSI MIN.) DRILLING SCREW THRU 0.125" 7/16 WI��SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC "L" ANGLE MULL BAR CLIP TWO REQ'D PER EACH END OF MULL 3" PVC MULL BAR IMPACT Q Z Q Z 3 MULL BAR I- Ow0 aWOp ZOZ ll W ¢�ZF J Z Zmm<xwox OF ,r �I INSTALLATION ANCHOR O ~ O CU Q = ¢ �I SEE TABLET o Z-rjZZF j0 —_ L ADD STRUCTURAL ELEMENTS SEALANT ALONG ""` Z < O Z U C Z V ~ - W O O tL U OUTSIDE EXPOSED +4=' — AS REO'D TO MAKE LEVEL FOR > ¢ 3 W = O Z O EDGE BY INSTALLER MULL BAR ¢Q ¢ Q F- U F Z uj PERIMETER SEALANT w 0 .52 =) w L) w BYINSTALLER MIN. EMBEDMENT INSIDE AND OUT FE CL Z y 0- O J rn ~ = m O � 52 SEE TABLE 1 F~ In d a ¢ a BY OTHERS SEE TABLEE - 1 MIN. EDGE DIST. SEE TABLE 1 rE, VERTICAL SECTION 9 TYPICAL FLANGE ("L" ANGLE) ANCHORAGE HEAD AND JAMBS SIMILAR FOR FLANGE INSTALLATION NOTES: 1. BOX FRAME MULL INSTALLATION SIMILAR TO FLANGE FRAME. •• ••• • • • 2. SILL STOOL MUST BE FL4H AGAINST INGIDI OG M11LLZD UQINIZ ft AFTER INSTALLATION. • • • • • • • • • •• • •• • ••• • 3. RECESS RETRO MULLIONIOCIP 3/Y"1AX. F&I CL%9ANFE QF V.l DOW UNIT AS NEEDED. 4. FOUR (4) ANCHORS REQUIRED PER "T" MULL CLIP, SEE SHEETS 2-3. THREE (3) ANCHORS RWWIREG RER "L" oMULL C�_J?•SEE SHUTS 2- 0 • • 5. SEAT MULLION TIGHI:Tt MULCCLIP. • • • • • • • • • • 6. FOR ANCHORAGE DETAILS FOA THE WINDIW, hgPER TO Ti"WINDOW SPECIFIC INSTALLATION DETAILS. ••• • • • • ••• • • z�z 9/26/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 INSTALLATION DETAILS FLANGE AIDE 09/27/12 VG #: REV.: CWS-836 B ALE: SHEET 1:2 9 OF 10 RETRO FIT MULL BAR CLIP II MULL BAR _T = 11 �, INSTALLATION ANCHOR SEE TABLE 1, SHT 9 JL SEALANT ALONG OUTSIDE EXPOSED EDGE BY INSTALLER oti°o EXTERIOR FINISH MIN. EMBEDMENT BY OTHERS ,• oa - — — -� SEE TABLE 1, SHT 9 PERIMETER SEALANT BYINSTALLER INS DEAN D OUT SUBSTRATE BY OTHERS , SEE TABLE 1, SHT 9 ^ MIN. EDGE DIST. / SEE TABLE 1, SHT 9 t' F^� 1 VERTICAL SECTION 10 TYPICAL FIN (RETRO FIT) ANCHORAGE HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION SEALANT ALONG OUTSIDE EXPOSED EDGE BY INSTALLER EXTERIOR FINISH BY OTHERS PERIMETER SEALANT — BYINSTALLER INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE 1, SHT 9 1900 SW 44TH AVE. OCALA, FLORIDA 34474 www.cws.cc 3" PVC MULL BAR IMPACT •L" ANGLE Q Z z 3 <Z3 Wwo W-j o Q Z w TWO EO'D PIER EACH END OF MULL W r z O Z M-- I- o a(n�>0mr :a MULL BAR f(ll LLL Z FW ZI-3:mS z = M Q OHO ¢_�¢ �JLJ! U o UtnZCLPcA(L z�-ZF-Z)U) IF J'1`�-= INSTALLATION ANCHOR H Z 00 Z U �n z Z) U O� Z SEE TABLE 1, SHT 9 �I < Q O W 0 z Fa- w m}}OL FiJ OpwooWI cr W Q a ZO w¢won>_ Fr ¢ 3 MIN. EMBEDMENT ¢H a i{ - -- SEE TABLE 1, SHT 9 MIN. EDGE DIST. / G VERTICAL SECTION SEE TABLE 1, SHT 9 10 TYPICAL FIN ("L" ANGLE) ANCHORAGE HEAD AND JAMBS SIMILAR FOR FIN INSTALLATION X� 9/26/2017 LUCAS A. TURNER, P.E. NOTES: FL PE # 58201 1239 JABARA AVE. 1. SILL STOOL MUST Bg tftisA A jAII`rTfNSIDE OF MULLED 1i WDOWS NORTH PORT, FL 34288 AFTERINSTALLATIgN. • • • • • • • PH.941-380-1574 • •• • • • • • • • • • • • SHEET DESCRIPTION: 2. RECESS RETRO MULLION CLIP*/8'bM W. FpR:1-4MOICE bFg WINDOW UNIT AS NEEDED. • • 900 • • • • • • • INSTALLATION DETAILS FIN 3. FOUR (4) ANCHORS REQUIRED PER " f" MULL CLIP, SEE SHEETS 2-3. THREE (3) ANCHORS REQUIRED PER "L" MULL CLIP, SEE SHEETS 2-3. DRAWN BY: DATE: •• ••• • ••• ••• • ADE 09/27/12 4. SEAT MULLION :IJHT TCtIv1ULL CL:P�• • • • • • DWG #: REV.: • • • 5. FOR ANCHORAGE DETAIl9FOR THE ';INa04, RtFER•TQ THE \NINDOW CWS-836 B SPECIFIC INSTAL?ATIONIDETAILS. • • • • • SCALE: SHEET 1:2 10DF 10 ••• • • • • ••• • • ••• • • • • •• •• URNER 1239 Jabara Ave. North Port, FL 34288 ENGINEERING & Ph. 941-380-1574 TCONSULTING, INC. FBPE C.O.A. #29779 Evaluation Report 836B September 26, 2017 Product Description: PVC 3" Mullion H-1758 Manufacturer: Custom Window Systems, Inc. 1900 S W 44`h Ave, Ocala, FL 34474 000000 Statement of Compliance: This report evaluates the above -listed product per the requirements oCFA; � • • Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the regiio *events ofihe 6th • • • • • Edition (2017) Florida Building Code including the High Velocity Hurricane Zone. T11plaroduct testing; �....� standards performed are outlined below. • .... . .. ..... ...... Technical Documentation: • • • • • • 0000 1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North PQR'Ftoo 0 4,0 2) Approval drawing CWS-83613, signed and sealed by Lucas A. Turner, P.E. • 0 ....:. ; • • 00 3) Test Reports NCTL-210-3833-1, -IA, -2, -2A, -3, and -3A, from National Certifietl.Testirrg Laboratories, Orlando, FL signed and sealed by Gerard J. Ferrara, P.E. 000000 0• 000 0 a. Testing Performed: TAS 201/202/203-94, ASTM E 1886-02/04/05, ASTM E 1999000 04/06/09, and AAMA 450-06 4) Supplemental Calcs. to support CWS-83613, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-836B. Limitations of Use: This product: • May be used up to the sizes and design pressures as shown in CWS-83613, using clips as shown in CWS-836B • Is Large Missile Impact Resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • May only be used with Custom Window System, Inc. windows, please see separate individual window unit approvals for applicable design pressures and for more details. The lower of the individual window design pressures and the mullion design pressures shall apply to the entire assembly. • Requires 6063-T6 aluminum mullion and clip extrusions. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do 1 intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. '�Ik1111111llil't#, O , t DREW 1 "i4 E IV Lucas ­4 : No 58201 9/26/2017 Turner = * w -* = Lucas A. Turner, P.E. 2017-09-28 FL PE #58201 STATE OF :btu 9 07:30+20:00 -, ,�•.,,� �.,.� E` •.OR1 .• ����S;,+ONA' '11%;,�`` BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Unks I Search F . Product Approval P r go USER: Public User t Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL5823-R8 Application Type Revision Code Version 2017 . • • Application Status Approved �•.• ; • • • • • Comments • • • • • • • Archived Q • • • . . ' • •••• • •• ••••• •••••• •••• • • Product Manufacturer Custom Window Systems Inc. • • 000 • • • : • • • • • • • Address/Phone/Email 1900 SW 44th Avenue : • •; •; • • • Ocala, FL 34474 ' • • ... ; • (352) 368-6922 Ext 291 • • • • • • jlathrop@cws.cc • .. . • • • • • • • • • Authorized Signature Kevin Pine kpine@cws.cc Technical Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Quality Assurance Representative Arturo Monteverde Address/Phone/Email 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext221 amonteverde@cws.cc Category Windows Subcategory Single Hung Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer t'j Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Lucas A. Turner PE-58201 Keystone Certifications, Inc. 07/21/2020 Steven M. Urich, PE it Validation Checklist - Hardcopy Received FL5823_R8_COI_EvalReport155D.p�f Standard AAMA/ W D MA/CSA/ 101/I . S. 2/A440-05 ASTM E1886-02 ASTM E1886-05 ASTM E1996-02 Year 2005 2002 2005 2002 ASTM E1996-05 PA/TAS 201/202/203 Equivalence of Product Standards Certified By Sections from the Code 2005 1994 Product Approval Method Method 1 Option D Date Submitted 09/28/2017 • ••+• •• Date Validated 09/29/2017 '.+' ; •••• •••••• Date Pending FBC Approval 10/02/2017 •..•.. 0 .••••• . ' • Date Approved 12/12/2017 foe*** • • + �.�.•.• •_w�_. • � • • • [Summary of Products _ _ _ FIL # Model, Number or Name Description " " • • • • 900000 5823.1 8100 Vinyl Single Hung 8100 Vinyl Single Hung ZImoac:) • • • • Limits of Use Installation Instructs§ns • • • • Approved for use in HVHZ: Yes FL5823 R8—II CWS-159D gdf• • •. ; • • • • • Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 ' •; • • • Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Large Missile, see Installation dwgs. for Max. size and FL5823 R8_g€ EvalReport155D.p-df DP. Outer lite in I.G. must be safety glazed when used above Created by Independent Third Party: Yes 30 ft. in HVHZ. Glass complies to ASTM E1300-04. 5823.2 SH-8100 Cont. Hd. & Sill SH-8100 Cont. Hd. & Sill (double Single Hung), Impact, 74 11/8" x 63". Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5823_H_II_CWS-440C.pdf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max. unit size 72-7/8" x 61-3/4". Outer lite in I.G. FL5823R8 AE EvalRego rt440C.pdf must be safety glazed when used above 30 ft. in HVHZ. Glass Created by Independent Third Party: Yes complies to ASTM E1300-04. 5823.3 SH-8100 Cont. Hd. & Sill SH-8100 Cont. Hd. & Sill (double SIngle Hung), Impact, 74 1/8" x 72". Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5823_R8 II_CWS-491C.pdf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +67.5/-67.5 Evaluation Reports Other: Large Missile, DP = +/- 67.5 psf, Max. size 74-1/8" x FL5823 R8AE_EvalReport491C.pdf 72". Outer lite in I.G. must be safety glazed when used above Created by Independent Third Party: Yes 30 ft. in HVHZ. Glass complies to ASTM E1300-04. 5823.4 I SH-8100 Vinyl Single Hung Oriel I SH-8100 Vinyl Single Hung Oriel Window w. HD FMR, 5 HI sash. Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL5823_a2_II_CWS-295E.PDF Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +70/-70 Evaluation Reports Other: Large Missile, 52" x 96" w/ 5 HI sash, +/- 70 psf. FL5823_U_AE_EvalReport295E.pdd FLANGE ONLY. Outer lite in I.G. must be safety glazed when Created by Independent Third Party: Yes used above 30 ft. in HVHZ. Glass complies to ASTM E1300-04. Back Next r Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. CopyriQht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ®in®'—p� Credit Card Safe . r � 0940 •s so :**so: 00 • SINGLE HUNG - LARGE MISSILE IMPACT (SHOWN W/DIFFERENT OPTIONS) 54 3/8" OVERALL FLANGE WIDTH 37 1 W 531/8" MAX. UNIT WIDTH OVERALL FLANGE WIDTH 48 15/16" GLASS DLO MAX UNIT WIDTH 3113/16" — 77 1/4" I I GLASS DLO MAX. A OVERALL I I A FLANGE HEIGHT O33 63 1/4" - - -I- OVERALL GLASSSS I 76" I I DLO FLANGE MAX. I I HEIGHT UNIT 1 O HEIGHT 6,B MAX UNIT X Dl0 wont D MAX 6 SASH X HEIGHT V - 4 ^ I l� I -A - C 6 453� LL 26- GLASS DLO GLASS DLO 491-1116' MAX. SASH WIDTH 315[]6' - MAX SASH WIDTH TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS.....1 GLAZING DETAILS...............................2 SECTION VIEWS & ALT. FRAME........3 EXTRUSIONS & B.O.M.........................4 ANCHOR SCHEDULE & NOTES .......... 5 INSTALLATION DETAILS.....................6 B GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED QLvw TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND 1900 SW 44TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA, FLORIDA 34474 IN ASTM E 1996 PER THE FBC. WWW.CWS.CC 2. GLAZING OPTIONS: (SEE SHEET 2) 8100 PVC 3. CONFIGURATIONS: "O/X". SINGLE HUNG 4. DESIGN PRESSURE RATING: IMPACT -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/09. -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER ON TESTESSURE AND GLASS TABLES ui 0-jo ASTMELTR13100-04e01/Og z w a LU O w 5. ANCHORAGE: THE 33 1 /3 % STRESS INCREASE HAS NOT BEEN USED w 0 LL ZOZ ¢-?!z a m � >- O ¢ 3' m IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR Z Z i 2 a ¢ w 0 0 DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD 00 () aFj a0�0 I. ANCHOR CALCULATIONS. 0Z -m- Z 6. PRODUCT APPROVED FOR IMPACT RESISTANCE. THE IMPACT SWEEP LOCKS ARE INTENDED TO BE LEFT UNLATCHED DURING NORMAL ¢ >_ OZVujZ�Um � -' 2 O O w Z ¢ O W F F Z - f 0 u GLASS OPERATION BUT MUST BE ENGAGED PRIOR TO EXPOSURE TO F ¢ ¢ } O DLO HURRICANE WINDS AND FLYING DEBRIS. w¢ Z ¢a a w (n w a0 d > 1 7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT w P O z: ¢ USED AT FIXED MEETING RAIL AND JAMB. ¢ = d W 3 w rn 8. SERIES / MODEL DESIGNATION SH-8100. rrr 4y r� 9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING: �J�y .ORE ..........T(�i� GEIISPy4, X = OPERABLE SASH, O = FIXED SASH GLASS 10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR J. �201 •• .�� : • DLO 1 LOCATION. # ;* 11. EXTERNAL WEEP SLOT = 1/4" x 1-1/4" LOCATED 4" FROM BOTH ENDS. �p01.STATE OF '' .0 t;.•' •t� R 12. SWEEP LOCKS INSTALLED ON WINDOWS OVER 36" x 62". �FS�� O LucasTurne r 2017-09-22 11:38-04:00 •• ••• • • • • • •• LOCATION MAX. DESIGN PRESSURE esRATING ' UNIT SIZE IKVACT•RATlNG' NON-HVHZ 53-1/8"x76„ +/-65 PSF IeRiE IMIAt LEIMP.ACT : • 0 • • .. 0 HVHZ +/- 67.5 PSF NON-HVHZ 36" x 62" +65 / -75 PSF HVHZ +67.5 / -75 PSF ••• • • • • • ••• • • • • • • • • • ••• • • ' • • • ••• • • • • ••• ••• ••• • • % •• •• •• • • ZZ LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 IEET DESCRIPTION: GENERAL NOTES AND ELEVATIONS AWN BY: DATE: ADE 06/10/08 /G r: REV.: CWS-155 D ALE: SHEET 1:1 1 OF6 7/8" OVERALL INSULATED GLASS 1/8' ANNEALED 7/16" AIRSPACE 5/16" LAMINATED GLASS 1/8" ANNEALED .090" PVB INTERLAYER BY DUPONT 1/8" ANNEALED QUANEX DURASEAL IG SPACER PURFECT GLAZE "H" OR SIKAFLEX 552 1/2" GLASS BITE GLASS TYPE A FIXED LITE 718" OVERALL INSULATED GLASS 1 EI" TEMPERED 7/16" AIRSPACE s 5/16' LAMINATED GLASS 1/8" ANNEALED .090PVB INTERLAYER BY DUPONT 1/8' ANNEALED QUANEX DURASEAL IG SPACER 18 PURFECT GLAZE "H" OR SIKAFLEX 552 I 1 1/2" GLASS BITE u -7/8" OVERALL INSULATED GLASS -1/8" ANNEALED .7/16" AIRSPACE 5/16" LAMINATED GLASS 1/8" ANNEALED .090' PVB INTERLAYER BY DUPONT 11W ANNEALED •QUANEX DURASEAL IG SPACER PURFECT GLAZE "H" OR SIKAFLEX 552 112" GLASS BITE GLASS TYPE A SASH LITE -7/8" OVERALL INSULATED GLASS -1/8" TEMPERED 7/16" AIRSPACE 5/16' LAMINATED GLASS 1/8" ANNEALED .090" PVB INTERLAYER BY DUPONT 1/8" ANNEALED QUANEX DURASEAL IG SPACER PURFECT GLAZE "H" OR SIKAFLEX 552 �SS BITE • •• • • • • ••• • • • • • • • • • 1900 SW 44TH AVE. OCALA, FLORIDA 34474 www.cws.cc 8100 PVC SINGLE HUNG IMPACT Q H - 3. QZ� 0 w o Q w O p w O_ LL zpz m-Z- zwq�>-OM�m FwZH3�S Z zmm<mwoo OHO <MI-¢ 0C/) a- �a Oz0ozoU- F-LL20OLLZ Q < wFxo_ w Ommc-owto-nw Fr z V1 Wa J O wl-0 d�Q> r 3a a o ¢ z.z LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34268 PH. 941-380-1574 I'I II��UUIII "' I--, III III III GLAZING DETAILS • • • • • • 000 • • go* DRAWN BY: DATE: • • • • • • • •• ADE 06/10/08 •• • ••• • • • • • • • • • • • • DWG#: REV.: GLASS TYPE B• • • • • • S TTI B S C PER FBC 2411.3.3.1 CWS 155 D GLASS TYPE B SASH LITE • • • • SCALE. FIXED LITE SHEET 1:1 20F6 ••• • • • • ••• • ••• • • • ••• • SECTION VIEW A -A NO SWEEP LOCKS ALLOWED FOR UNITS 36" x 62" AND UNDER. ITEMS NOT SHOWN FOR CLARITY: 22, 27-28, 33-37, 43-45 INTERIOR ALTERNATE FIN FRAME INTERIOR SECTION VIEW B-B NOTE: LEFT SIDE SHOWS FIXED SECTION VIEW, RIGHT SIDE SHOWS SASH SECTION VIEW. • • • • • • ZccT%'cVIE%&C• • • • • •• SWEEP LOCK REQUIRED FOR SIZES OVER 36" x 62". i•• •• • • • •• • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8100 PVC SINGLE HUNG IMPACT a z 3 az3 ow0 Qwop o zo?}o�3m x rw�ZF-3gx z Zxf¢¢w00 0 OF-O axrx UMF-ZaPUd Z 00 --�O- F— g O�U cr �¢ z ~ 0oXco0LuCow ar zLoa 0�mF- 0 wF0 d�¢> ¢ x x w�w� a F a x a zz 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SECTION VIEWS AIDE 1 06/10/08 CWS-155 D :ALE: SHEET 1:2 30F6 DESCRIPTION Reinforcement for SBR Sash Side Rail Reinforcement for SSR Glazing Bead Keeper, Sweep Lock #8 x 1/7, Pan Head, Tek Sweep Lock Barrel Fastener Block & Tackle Balance Purfect Glaze "W or Sika W stp., 0.270 x 0.1 #8 x 2-1/2 PH Ma #10 x 1 1/2" Panh, x 1 1/4" Screen Cloth Screen Spring Screen Pull Tab Set Blk. 85 Dur. 1/8" x 5/8" x 2" #8 x 5/8 Phil Pan One PVC MIKRON PVC MIKRON PVC MIKRON ALUMINUM KEYMARK PVC MIKRON PVC MIKRON ALUMINUM KEYMARK PVC MIKRON ALUMINUM KEYMARK PVC MIKRON ALUMINUM KEYMARK PVC MIKRON ZINC SULLIVAN STEEL FASTENAL ZINC SULLIVAN STEEL FASTENAL PVC MIKRON PVC MIKRON ZINC FASTENAL ZINC FASTENAL STEEL INTERLOCK STEEL INTERLOCK Wht STEEL FASTENAL ALUMINUM ALLMETAL PLASTIC M&M RUBBER DAPA VINYL WIER STEEL HURLEY STEEL HURLEY RUBBER FRANK LOW] ZINC FASTENAL PLASTIC M&M RUBBER TEAM 43 1 P-3059 Sash Cam PLASTIC M&M 44 P-3295 Take Out Clip STEEL SUMMIT 45 P-3342 Seam Sealer SILICONE SCHNEE 46 P-3752 Hole Plug PLASTIC M&M 47 H-6048 Frame Head, FIN, Single Hung PVC MIKRON 48 P-4959 W sm.. 0.420 x 0.187 back NYLON ULTRAFAB NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. PVC FRAME FLANGE-6031 PVC FRAME FIN-6048 1 5/16" 4 7/8" -- PVC SASH STOP - 6025 wi 3/6" 11 T 1/16" REINF. S.B.R./S.S.R. - 1498 1 15/16"� e 1 5/8" 4� � 1/16" PVC SASH BTM. RAIL-6028 1 3/16' 10 1 5/ 8"i 1 /16" PVC SASH SIDE RAIL-6004 6 v1s" PVC SCREEN CATCH -6013 r--2 3/16" 6 1' 1 /16" PVC SASH TOP RAIL-6027 1 1/2" 4 2 1/16" FIXED RAIL - 1836 9116" 5 1 5/16" oas• PVC FIXED RAIL COVER - 6063 FRAME CORNER CONSTRUCTION CORNER WELD (ALL SIDES) 1:8 FIXED MEETING RAIL SCREWED TOGETHER WITH OUTERFRAME 1:8 5/16" 5 PVC SCREEN SUPPORT - 6014 3/4" 1 9 5/8 � 1/4"1 7/1 F� 1 15/il',� 7 1,16 �Zi /16" I� REINF. BTM RAIL-1699 • • • • R�NF,*T Oj R)V-1J97: • "C GLAZING 13EAD-6064 • •• • • • • ••• •• ••• •• • • • ••• 1/2" .. ... . 3116" • • • • • • • • • • • • • SiREW�•UI�pORT-3113 WINDOW SY5TEM5 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 8100 PVC SINGLE HUNG IMPACT Z 3 "1Z3 p: ow0 QwoLu _0 Z0Z>0x3m LL �w3Zr3gx Z Zxi¢¢WOO OI-O a=FX U(n�ZaFC/)LL o Z-0)-Z OZUajZoU- F-LLMOOLLZ cr 2< F-I' O- � Oo�»3o� W cr wo Www LLmwa OJrnH 0 WF-0 mm¢>- [L ~ a Ir a. LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 BOM AND EXTRUSIONS ADE 06/10/08 VG I: REV.. CWS-155 D 'ALESHEET 1:2 4 OF 6 • •• •• • • • •• •• ••• • • • ••• • 15" MAX. 6" MAX. 6" MAX. 14" MA) (TYI 4" 4" ANCHOR LAYOUT - (FLANGE) SIZES OVER 36" x 62" V MAX. (TYI V MAX. (TYI 8" MAX. O.C. (TYP.) `MTG RAIL ANCHOR LAYOUT - (FIN) SIZES OVER 36" x 62" —1-1 6" MAX. 6" MAX. 10 13/1 MAX. C (TYP.) 4" 4" MAX. (TYP MAX. (TYP 8" MAX. O.0 (TYP.) gMTG RAIL ANCHOR LAYOUT - (FLANGE) SIZES 36" x 62" AND UNDER 29mMsd 1900 SW 44TH AVE. OCALA, FLORIDA 34474 (TYP.) WWW.CWS.CC 8100 PVC SINGLE HUNG IMPACT ANCHOR LAYOUT - (FIN) SIZES 36" x 62" AND UNDER Q F 3. az3 ow0 awrpo W z0z ¢rz!Z 0 LL Q0n 3>-0¢3'm I-wzi--3gx O OI•-O Q=F¢ a 00 -DU- -w200LLz cr 2 < I.- F- w ¢¢Fy739m Ow0'r(n0W V)W z=)a O_jM 0 wr0 wo¢� 3 a a ¢ a %��pnnrnry 0 PtVORE W T lt, E N 6Pc:•x.�G g� GQ,i�I J' No 58201 =ro: ice; STATE OF !113 NOTES: I!!rlp NAl--.0 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1 /16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. /2y____z' 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 8. 9/222/2017 LUCAS A. TURNER, P.E. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. FL PE # 58201 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BF.AED ffA:iBS:RAfrES WITH STRENGT6-* LESS THAN THE MINIMUM 1239 JABARA AVE. NORTH PORT, FL 34288 SPECIFIED IN TABLE 1, SHEET 6. • • • • • • • • • PH.941-380-1574• • • • • • 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BAY_ D W0861) ®U0KS,d0F Lka T!:'O SMVTRATE. SHEET DESCRIPTION: INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1 X WOOD BUCKS BETWEEN THE PRODUCT AND THE SU&M-RATED • • • • • a INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF IX BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. ANCHOR SCHEDULE AP NOTES 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD AND METAL. DRAWN BY: DATE: 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD:WD INS�ALLED TQI ANSFM WIND UOAD&TOoTHE STRUCTURE. ADE 06/10/08 DWG r: REV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 6. CONCRETE AND MASONRY SUBSTRATESOAA4 NOT•BE C69A KEi • • • • •( • • • • • : • • !• • • 9. SEALING AND FLASHING FOR CWS-155 D STRATEGIES OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRONT VEFFSION OF THEPREFGRENCE DCtCtM9V9: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMAANDMA 250(BOX WINDOWS), FMA/AAMA/WDMA 300(EXTERIOR DOORS) SCALE: SHEET 1:25 50F6 ••• • • • • ••• • • • • • •• • •• • • • • • • • • • ••• • • • ••• •• • •• MIN. EMBEDMENT TYPICAL HEAD ANCHORAGE SEE TABLE 1 SUBSTRATE BY OTHERS MIN. EDGE DIST. 114" MAX. SHIM SEE TABLE 1 SEE TABLE 1 SUBSTRATE BY OTHERS SEE TABLE 1 1 MIN. EDGE DIST. MIN. EMBEDMENT SEE TABLE 1 PERIMETER SEALANT SEE TABLE 1 BY INSTALLER INSTALLATION ANCHOR IN AND OUT SEE TABLE 1 SEALANT BEHIND FLANGE BY INSTALLER 1/4" MAX. SHIM INSTALLATION ANCHOR SEE TABLE 1 SEALANT BEHIND - FLANGE BY INSTALLER PERIMETER SEALANT - BY INSTALLER INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE i 1/4" MAX. SHIM MIN. EMBEDMENT SEE TABLE 1 I I MIN. EDGE DIST. �� SEE TABLE 1 L 1 VERTICAL SECTION 6 TYPICAL SILL ANCHORAGE -' PERIMETER SEALANT BY INSTALLER INSIDE AND OUT SEALANT BEHIND FLANGE BY INSTALLER rB') HORIZONTAL SECTION 6 TYPICAL JAMB ANCHORAGE TABLE 1: APPROVED INSTALLATION FASTENERS FRAME TYPE SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. FLANGE CONCRETE (2.0 KSI MIN.) 3/16" I W TAPOON 1-1/2" 1-1/8" FLANGE HOLLOW OR GROUT -FILLED CMU (117 PCF MIN.) 3/16" RW TAPCON 1" Z. FLANGE CONCRETE (285 KSI MN.) 3/16" ELCO ULTRACON i" 1" FLANGE GROUT -FILLED CMU (ASTM C-90) 3/16" ELCO ULTRACON 1-1/4" 2-1/7 FLANGE 2X MIN. SOUTHERN PINE (G=0.55) 3/16" ITW TAPCON OR ELCO ULTRACON 1,3/8" 7/8„ FLANGE 2X MIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-3/8" 7/8" FLANGE 16 GAUGE (0.060")MIN. STEEL STUD (33 KSI YIELD MIN) #10-16 HILTI KWIK-FLEXOR ITW TEKS SELF -DRILLING SCREW FULLTHREAD THRU 0.060" 7/16" FLANGE 1/8" ALUM. (6063-T5 MIN.) OR 1/6" STEEL (33 KSI MIN.) #10 GRADE 5 SELF -TAPPING / DRILLING SCREW FULL THREAD THRU 0.125" 7/16" FIN 2X MIN. SOUTHERN PINE (G=0.55) #8 WOOD SCREW 1-1/2" 7/16" 2zmffl MIN. EDGE DIST. SUBSTRATE SEE TABLE 1 BY OTHERS 1900 SW 44TH AVE. SEE TABLE 1 OCALA, FLORIDA 34474 1/4' MAX. SHIM WWW.CWS.CC 8100 PVC SINGLE HUNG SEE TABBLEDMENT IMPACT Q Z ¢Z3 Op Q W PERIMETER SEALANT Z W J o w z� BYINSTALLER INSIDE AND OUT W O U. Z O Z ¢- Q y - } 0 EC _;9: m 2 a¢ Zp INSTALLATION ANCHOR 2 W O SEE TABLET 0 01-0 Cj Q=Fx SEALANT BEHIND FIN BY INSTALLER Z 0 rn� Z LL P U) IL V - \ OZ C7 U � n /`Cl HORIZONTAL SECTION F _ cn 0 tL U F- H O Q O} �6J TYPICAL FIN ANCHORAGE < F HEAD AND SILL SIMILAR FOR FIN INSTALLATION H O cc F } 0 O W lL xc/)0w InW (n Q_ J O wFox E.�m} a F- a ¢3a PERIMETER SEALANT - BY INSTALLER • • • • • • • • INS DE AND OIST • • • • • • • • • MCIRIZONTeL 9F-CT•ON• • •6 • B (F A IN TION • • 000 yF•AD I� IL�SI LAB .LIAR BOX INSTALLATION FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE, UP TO AND I14GLUP%19 A BOAC -FRAME APPLICATION IS ACCEPTABLE PROVIDED: • MIN. 1 / fI LETOF CON9T436)CTIGIPT-GRADE:ADHgSItE CAULK IS APPLIED INSIDE N OU-C ULL PERIMETER, BIMNST.ALLE61. • PRODUCT ANCWRAGE IS IjACVhDANCEeMTN R60UIREMENTS AS SHOWN FOR FLANGE WINDOWS. • • • • • • • z� LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 HEET DESCRIPTION: INSTALLATION DETAILS RAWN BY: DATE: AIDE 06/10/08 WG t: REV.: CWS-155 D GALE: SHEET 1:2 60F6 URNER 1239 Jabara Ave. North Port, FL 34288 ENGINEERING & Ph. 941-380-1574 TCONSULTING, INC. FBPE C.O.A. #29779 Evaluation Report 155D August 28, 2017 Product Description: Series 8100 PVC Single Hung, Large Missile Impact, 53 1/8" x 76" unit size at up to +/-67.5 PSF, 36" x 62" unit size at up to +67.5/-75 PSF, 7/8" Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite — Air — 5/16 Laminated (1/8Ann-.090PVB-1/8Ann) inboard liV .. ..•. Manufacturer: Custom Window Systems, Inc. 1900 SW 441h Ave, Ocala, FL 34474•* Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the re4ir*rents o9dw &.h Edition (2017) Florida Building Code including the High Velocity Hurricane Zone. 'LZ� pOlVduct testmL standards performed are outlined below. �, • • • •YY• •YYYY• Technical Documentation: 0 ' 0 0*0 1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Pprt,^ :" 2) Approval drawing CWS-155D, signed and sealed by Lucas A. Turner, P.E. •• • • •. 3) Test Report NCTL-210-3668-1, -IA, -2, -2A, 3669-1, -IA, -2, and -2A, by National CertiPldd•� Testing Laboratories, Orlando, FL, signed and sealed by Gerard J. Ferrara, with testing performed: TAS 201, 202, 203 1994, ASTM E 1886, 1996 2002/2005, and AAMA A440 2005 4) Supplemental Calcs. to support CWS-155D, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-155D. Limitations of Use: This product: • May be used in O/X configuration in sizes, design pressures, and with max. glass DLO heights as shown in CWS-155D • Is impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires 7/8" Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite (Tempered required above 30 ft in HVHZ) — Air — 5/16 Laminated (1/8Ann-.090PVB-1/8Ann) inboard lite • Requires Kuraray (Dupont) PVB Interlayer per Miami -Dade N.O.A. 16-11117.02t • Requires Quanex (Mikron) white rigid PVC framing per Miami -Dade N.O.A. 17-0206.10' t I have evaluated the materials in these NOAs and find that they comply with the requirements of the 6"' Ed. (2017) Florida Building Code for use in this product. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. OtS9111011q �,REW '%S��� 'b �......... Lucas ;��'� Turner -4 : No 58201 % 8/28/2017 2017-08-30 Lucas A. Turner, P.E. 15:59+20:00 .-9 STATE OF 1W: FL PE #58201 ID ''� 10t4A� E���. O BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links I Search r Product Approval USER: Public User i Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL11103-113 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) 0 Custom Window Systems Inc. 1900 SW 44th Avenue Ocala, FL 34474 (352) 368-6922 Ext291 jlathrop@cws.cc Kevin Pine kpine@cws.cc Jay Lathrop 1900 SW 44th Ave Ocala, FL 34474 (352) 368-6922 Ext 291 jlathrop@cws.cc Arturo Monteverde 1900 SW 44th Ave Ocala, FL 34474 (352) 368-6922 Ext221 amonteverde@cws.cc Exterior Doors Sliding Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ® Evaluation Report - Hardcopy Received Lucas A. Turner PE-58201 Keystone Certifications, Inc. 07/21/2020 Steven M. Urich, PE 0 Validation Checklist - Hardcopy Received FL11103_R3_CQI_EvalReport298C.pdf Standard Year AAMA/WDMA/CSA 101/I.S.2/A440-05 2005 ASTM E1886-05 2005 ASTM E1996-05 2005 TAS 201/202/203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 09/28/2017 09/29/2017 10/02/2017 12/12/2017 • • •See Sege•• • • s • ummary of Produ ;'•-•'"• FL # Model, Number or Name Description •ege • : • • • • 11103.1 SGD-8900 PVC Sliding Glass Door. SGD-8900 PVC Sliding G4ass-Door. : • • • • • •. •. Limits of Use •••••• Installation Instructions • •••• • ••••• Approved for use in HVHZ: Yes • FL11103_g3_jj_ Sees •.•••. • Approved for use outside HVHZ: Yes Verified By: Lucas A. AIM*V201 • • Impact Resistant: Yes Created by Independent Third PartyrYes • • • ••: • Design Pressure: +60/-60 Evaluation Reports • . •••••• . g • Other: Large Missile, DP = +/- 60 psf, Max. panel size 4' x FL11103 R3 AE EvalRe h 8C.�df • • • • • • 8'. Config. include OXXO, OXO, OX, XO. Glass complies to Created by Independent Third Party! Yes • • ASTM E1300-04. 000• Back 0Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: MM ®®®-- Credit Card Safe SLIDING GLASS DOOR - IMPACT 145 13/16" MAX UNIT WIDTH 48 7/8' MAX PANEL WIDTH 41 GLASS S 16" AAX1NIT DLO_ iEIGHT MAX'D GLL SSO O PANELLL HEIGHT C "L TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS .....................1 SECTION VIEWS OXXO & GLAZING DETAIL.....2 SECTION VIEWS ONO & XO................................3 EXTRUSIONS & B.O.M.........................................4 ANCHOR SCHEDULE & NOTES ............................5 INSTALLATION DETAILS.....................................6 1 1 GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION AND IS RATED FOR IMPACT USE IN WIND ZONE 4 AND HIGH VELOCITY HURRICANE ZONE (HVHZ) AREAS AS DEFINED IN ASTM E 1996 PER THE FBC. 2. GLAZING DETAIL: (SEE SHEET 2) 3. APPROVED CONFIGURATIONS: "OXXO", "OXO", "XO", "OX" Qmmmsiv 1900 S FLORIDA4E. 1900 SW 44TH AVE. W W W CW OCC34474 8900 PVC 4. DESIGN PRESSURES: SLIDING GLASS -NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS DOOR - IMPACT TABLES ASTM E-1300-04e01 /09. -POSITIVE DESIGN LOADS BASED ON TESTED PRESSURE, WATER J - a z 0 INFILTRATION TEST PRESSURE, AND GLASS TABLES ASTM E-1300-04e01/O9. F w � od 5. ANCHORAGE: THE 33 113 % STRESS INCREASE HAS NOT BEEN USED IN THE W Z O Z ¢ Z O0 En DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR INSTALLATION DETAIL o � w � Z i WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR Z z x i a ¢ w O O CALCULATIONS. O O � O cj a ¢a 6. PRODUCTS APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT z �Z O O U uj j U REQUIRED. Q w W O O O z 7. ALL FRAMES ARE PROCESSED AND SCREWED TOGETHER. VENTS FULLY WELDED. a w ¢ ¢ O U ~ Z �i O0cr U)pwCnw 96" MAX UNIT WIDTH 48 7/8' MAX PANEL WIDTH 7I� 41 GLASS 16" DLO AAX _ 1N:T 1EGFIT sa1/2' MAX PANEL E O X HEIGHT 86 3/8' GLASS IDLO 8. SERIES / MODEL DESIGNATION: SGD-8900. 9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING: X=OPERABLE SASH, O=FIXED SASH. 10. SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS. 11. EXTERNAL WEEP SLOT = 1/4 x 1" LOCATED 4" FROM BOTH ENDS. 1 •• ••• • • • • • •• • •• • • • • ••• • •• ••• •• • • • •• LucasTurne r 2017-09-22 12:26-04:00 CONFIG. MAX. UNIT SIZE MAX. PANEL SIZE DESIGN PRESSURE R TING'•• IMPACT RATING ••• ••• • XO 96" x 9611 48-7/8" x 93-1/2" • • • • • • • • +/-60•PSF: • • • • • • • • • • L-ANCE MIEMILLNPACT OXO 145-13/16" x 96" OXXO 191-1 /8" x 96" • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • W (/1 W Q J (n ~F- ?=a ItQ-vJ ¢ w3 _. a m , z :- 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 GENERAL NOTES AND ELEVATIONS AIDE I 06/03/08 CWS-298 C :ALE: SHEET 1:33.33 1 OF 6 SECTION B-B PAIR OF ANCHORS AT EACH CLIP. SEE SHT 6 FOR SPACING SECTION C-C FIXED PANEL ATTACHMENT NOTE: INSTALLATION WITH NO SILL RISER ALLOWED ONLY WHERE WATER INFILTRATION RESISTANCE IS NOT REQUIRED. OUANEX DURASEAL IG SPACER 1" OVERALL 3/16" TEMPERED 3/8" AIRSPACE 7/16" LAMINATED GLASS 3/16" ANNEALED GLASS .OW SENTRY GLASS IONOPLAST INTERLAYER 3/16" ANNEALED GLASS PURFECT GLAZE"H" SIKAFLEX 552 13/16" GLASS BITE •• •• • • ••• • • • • • • • • • 1:1a3 • • • SETTING BLOC • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • WINDOW SYSTEMS k_—ZI 1900 SW 44TH AVE. OCALA, FLORIDA 34474 www.cws.cc 8900 PVC SLIDING GLASS DOOR - IMPACT a - 3 az� ow0 In 0 zoz>O zm u- �w3z�3gx z zxi¢¢w00 ono axFx o U/n F- ZD-f-cncL z�c-zr0Lo OZOInZE)U— F— o O LL Z ¢} gm a3.Owg0_ w �o ri030 � LLcnw�OJfAF- d 0 wF0 Q-3: F- am . a ¢�a z�- 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 HEET DESCRIPTION. SECTION VIEWS - OXXO AND GLAZING DETAIL RAWN BY: DATE: ADE 06/03/08 WG:1: REV.: CWS-298 C DALE, SHEET 1:2.63 20F6 SECTION D-D SECTION E-E • •• • • • • ••• • •• ••• •• • • • •• Qmffms 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8900 PVC SLIDING GLASS DOOR - IMPACT i 3 az3 ow0 wwoo w ZOOz m— t o aw3>Ox3m LL r-w zr-3: z zxiaQwp0 yZ -zoo-zo 0 r-LLMOOLLZ Q30wpx0_ w LL Qfn0 W WLu FE z0a 0-1W 0 w�Q wo¢>- a a x3a z� 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SECTION VIEWS - OXO AND XO/OX • • • • • • • • • • • • • DRAWN BY: DATE: s • i i WQTES� • ADE 06/03/08 • • • 1.gTE1NS NOW SHOWN GOF:CLARITY: 10, 26-32 DWG k: REV.' • • 2.*/EAT•ICAL SECV8N C eBE SEEN ON SHEET 2. CWS-298 C SCALE: SHEET 1:2.63 3 OF 6 • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • 5 X _X5520 0.270 X. 5 15/16" 1 17M" P 9 0 1 /8" ��d❑d❑❑❑dam PVC OUTER FRAME - 6042 3 3 4 2 11116" 1I6' REINF. - 1993 1 718" 1 7/8" � DI 4 D 6 5 9/16" 3 9/16" 1 /8" g Ll L 1KEYMARK ALUM PVC PNL INTERLOCK - 6060 PVC PNL LOCKSTILE - 6059 PVC PNL INTERLOCK - 6033 FRAME CONSTRUCTION FRAME CORNERS SCREWED TOGETHER 1:10 VENT CONSTRUCTION VENTS FULLY WELDED 1:10 — , 1.— —1-1 I — nc (MAntl ALUM 1 11/16" 27 S-1930 PANEL TRACK, ALUMINUM, SGD, SILL KEYMARK ALUM 1/2' r 2" �21/16" 28 S-1726 REINFORCEMENT, ASTRAGAL, SGD KEYMARK ALUM 15/6"1I 29 S-1737 HIGHRISE SILL, ALUMINUM KEYMARK ALUM e e 5 30 S-6037 GLAZING BEAD 1.00", SGD MIKRON PVC 6 3 31 S-6041 TRACK, SCREEN, SGD MIKRON PVC 21LT, 32 S-6046 SUPPORT WELD, SGD MIKRON PVC 33/16 1/16" 31116" 25/8" 115116" 33 GLASS (SEE SHEET 2) 1�• 34 H-6044 SCREEN CHANNEL MIKRON PVC 1/e" 1/16" 35 S-6045 SCREEEN ADAPTOR MIKRON PVC D 36 P-4278 WSTP., 0.Z X 1.25" DUST PLUG ULTRAFAB 37 S-1764 ISILL THRESHOLD COVER (8900) KEYMARK ALUM 38 P-4366 IWSTP., 1" X 7.1" X 07' DUST PLUG ULTRAFAB PVC INTERLOCK SNAP - 6061 FIXED PNL CLIP - 4295 FIXED PNL COVER - 1597 REINF. - 1775 HIGHRISE - 1737 PVC ASTRAGAL - 6043 BACK FIN ULTRAFAB 211/16" 2• SULLIVAN PVC 21/8• 3/4" T v1s r I�----� 5/8" 1 /2• �{ jam- (36� 1 3/9" 13116' L 1/16" 8 3/L 1/6' ROLLER TRACK - 1930 L _ _ _ PVC SCREEN ADAPTOR - 6045 SILL THRESH COVER -1764 • • • • • • • • • • • • • �"' • • • • 0 0 0 W/CrMELD SUPPORT - 6046 7/8^ 2 1/16" • • • • • • • • • • • 2 3/16" -�I e • • • • • • • • a 3/9" II1^--('^') 1�• • • • • �i�. a `• • • • 5/9, 4 2 1 1/8 3 I 30 1 1/2' 1 1I/4" s16 1 1 /16" ••• e•• •l 118" • •e• • 31 1/16" L • • 1/16" • • • FIXED PNL SUPP:)%- 17:2 1/1s" PVC SCREEN CHANNEL - 6044 PVC TRACK FILLER - 6040 • • • • • • • • • e :p SCREEN TRACK - 6041 • • REINF. - 1726 NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE SPECIFIED. PVC GLAZING BEAD - 437 • • • • • • • • • • • • •• •• • • • •• •e ••• • • • ••• • • WI� MS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 8900 PVC SLIDING GLASS DOOR - IMPACT a z 3 az3 r pw0 Qwop w Z JO z Q- z F u- Hw ZF-3:2T Z zmm<mwp0 OFOU¢=F¢ 0(n1--ZaHcna 0 Z--Z�(n O 000S (/j-OU- P7z,gpOu.0 > ¢3OwF=Oz W p0¢aiowCmw W(o w Fa ¢J O�O¢ cn >- ¢a x 9� 0 7 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 BOM AND EXTRUSIONS ADE 06/03/08 ✓G B: REV.: CWS-298 C ALE: SHEET 1:2 40F6 6" MAX.— (TYP) �-r 8" (TYP) 6' MAX. (TYP) 12 MAX O.C. ) (TYP) 4- (TYP) 18" MAX. O.C. (TYP) i i i I I I ANCHOR LAYOUT NOTES: 1. INSTALL TWO ANCHORS AT EACH LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 2. SHIM AS REQ'D AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLET SHEET 6. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT gl?&ED VU:STDAT'�S PI114 SIREN8?HS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 6. • • • • • • • • • • •• • • • • ••• • 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMENT SHALL BE BE`POND WOOS BW-KE, 116USEDANTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE 1X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. IR&ALLA-MCINS T&NOLLOW CIOU91EWIRE THE USE OF 1 X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 2" FOR MASONRY, 1" FOR WOOD AND METAL •• ••• • ••• ••• • 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORb(1ND IN:TALLEDQ RA%f ER WINd�LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLE 1, SHEET 6. CONCRETE AND MASONRY SUBSTRATES WAY NpT Bi Clw[6 • • • • • • •• • • • % • • 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURF? NT VL4ISION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMAANDMA 250(BOX WINDOWS), FMA/AAMAANDMA 300(EXTERIOR DOORS). ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • 1900 SW 44TH AVE. OCALA, FLORIDA 34474 www.cws.cc 8900 PVC SLIDING GLASS DOOR - IMPACT a z 3 aZo ¢ko _o Z0O �>-0m3:m w �wZi--3gx Z ZZM<mwpO OHO <=ram U UyZaFya 1=-wi00wZ } �QO�FFO- H OoujU)pwrnw Q zLL �'L 0-iv_1� a d0�>w0 dacm I 7�z- 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 ANCHOR SCHEDULE NOTES ADE 06/03/08 JG #. REV.. CWS-298 C 'ALES SHEET 1:20 50F6 SUBSTRATE BY OTHE SEE TABLE 1 PERIMETER SEALANT BYINSTALLER INSIDE AND OUT INSTALLATION ANCHOR SEE TABLE 1 PERIMETER SEALANT - BYINSTALLER INSIDE AND OUT DO NOT COVER WEEP HOLES SUBSTRATE BY OTHERS SEE TABLE 1 SEALANT UNDER SCRE1 HEAD BY INSTALLER TYPICAL HEAD ANCHORAGE 27116" MIN. i SEETAGEDIST. i i i � SEE TABLEI MIN. EMBEDMENT SEE TABLE 1 1 -1/4" MAX. SHIM INTERIOR - SEALANT BETWEEN SILL RISER AND FRAME BYINSTALLER MIN. EMBEDMENT SEE TABLE 1 F--2 7/16 I --1 MIN. EDGE DIST. MIN. SEE TABLE 1 Q VERTICAL SECTION \,±J TYPICAL SILL ANCHORAGE INTERIOR 114" MAX. SHIM MIN. EMBEDMENT SEE TABLE 1 PERIMETER SEALANT BY INSTALLER—/ INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE 1 %B1 HORIZONTAL SECTION \6J TYPICAL JAMB ANCHORAGE TABLE I: APPROVED INSTALLATION FASTENERS SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. CONCRETE (2.0 KSI MIN.) 3/16" ITN TAPCON 1" 3" CONCRETE (2.85 KSI MIN.) 3/16" ELCO ULTRACON 1-3/4" 1" HOLLOW OR GROUT -FILLED CMU (117 PCF MIN.) 3/16' ITW TAPCON 1" 3" HOLLOW OR GROUT -FILLED CMU (ASTM C-90) 3/16" ELCO ULTRACON 1-1/4" 2-1/2" 2X MIN, SOUTHERN PINE (G=0.55) 3/16" ITW TAPCON 1-3/8" 1" 2XMIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-3/8" 1" 16 GAUGE (0.060") MIN. STEEL STUD #10-16 HILTI KWIK-FLEX OR ITW FULL THREAD (33 KSI YIELD MIN) TEKS SELF -DRILLING SCREW THRU 0.060 7/16 1/8" ALUM. (6063-T5 MIN.) OR #10 GRADE 5 SELF -TAPPING / FULL THREAD 1/8" STEEL (33 KSI MIN.) DRILLING SCREW THRU 0.126' 7/16 FIXED PANEL CLIP ANCHORS INTO: CONCRETE (2.0 KSI MIN.) OR 3/16" ITW TAPCON 1" 3" HOLLOW OR GROUT -FILLED CMU (117 PCF MIN.) FIXED PANEL CLIP ANCHORS INTO: CONCRETE (2.85 KSI MIN.) OR 3/16" ELCO ULTRACON 1-1/4" 2-1/2" HOLLOW OR GROUT -FILLED CMU (ASTM C-90) MIN. EDGE DIST. SEE TABLE 1 INSTALLATION ANCHOR SEE TABLE 1 TWO ANCHORS PER FIXED CLIP THROUGH PRE -DRILLED HOLES 1/4" MAX. SHIM FIXED PANEL MIN. EMBEDMENT SEE TABLE 1 FIXED PANEL 12• EDGE DIST. SEE TABLE 1 17 7/8' ❑ MAX. O.C. ••• • • • • FIXED PANEL CLIP • • • • • • CLIP ANCHORS MUST • • • • • • • • • BE LOCATED A MINIMUM • • • DISTANCE OF 3" AWAY • • • • • • • • FROM ANY MAIN FRAME ANCHOR. INSTALLATION • • • • • • • • ANCHOR (fYP) • • • C HORIZ NTAI E TION FIXED tANELCLIP eETlRIL • 6 AXEDIANEL•ANEHORAGE • • •• • • •• • • NOTE: FIXED PANEL CLIP ANCHORS INTO WOOD OR METAL SHALL FOLLOW THE ANCHOR TYPE, MIN. EMBEDMENT AND MIN. EDGE DISTANCE LISTED IN TABLE 1. • •• •• • • • •• •• ••• • • • ••• • • WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8900 PVC SLIDING GLASS DOOR - IMPACT Q F- Z Q Z W0 0 pW0 argw o w zvoz m-gym_ �wzr�g= Z O Z2mQm WOp OI-O Q=�¢ U/n F'Z a H to D. Q zo -ooz0 F--u-mo u-Z Q3:Owr-=O- ( 0WW aWF IlnWywco O_j(o F- a Q 0 r uj a Er zz 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 IEET DESCRIPTION: GENERAL NOTES AND ELEVATIONS IAWN BY: DATE: ADE 06/03/08 JG #: REV.: CWS-298 C ALE: SHEET 1:2.67 6 OF 6 URNER ENGINEERING & CONSULTING, INC. 1239 Jabara Ave. North Port, FL 34288 Ph. 941-380-1574 FBPE C.O.A. #29779 Evaluation Report 298C August 28, 2017 Product Description: Series 8900 PVC Sliding Glass Door, LM Impact, 4'x8' nominal panel size max. Manufacturer: Custom Window Systems, Inc. 1900 SW 441h Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above -listed product per the rcqu4eTents of;9*-' • • • • • • Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the regLirenlents (fbg33 h •, Edition (2017) Florida Building Code including the High Velocity Hurricane Zone. 6eproduct testing • • • • • • standards performed are outlined below. :....; .... . .. Technical Documentation: ..... • ...... .... 1) This report, by Lucas A. Turner, P.E., at 1239 Jabara Ave., North RortpliL ..... prepared .... •. • • • • 2) Approval drawing CWS-298C, signed and sealed by Lucas A. Turner, P.E. • • • : . .' 3) Test Reports NCTL-210-3956-1 and -I A, from National Certified Testing Laboratories, f)j jandp, • • •.:. FL signed and sealed by Gerard J. Ferrara, P.E. • .. a. Testing Performed: TAS 201/202/203 1994, AAMA/WDMA/CSA I'M /IA.2/A44(V 0. ...... 2008, and ASTM E 1886/ 1996 2005 0000 4) Supplemental Calcs. to support CWS-298C, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-298C. Limitations of Use: This product: • May be used in up to 48 7/8" x 93 1/2" panel sizes (96" max. door height), with glass types and max. glass daylight sizes as shown in CWS-298C • Achieves design pressures of+/-60 psf • Is Large Missile Impact Resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires Kuraray (Dupont) SentryGlas Interlayer per Miami -Dade NOA #14-0916.1 It • Requires Quanex (Mikron) white rigid PVC framing per NOA #17-0206.10t t I have evaluated the materials in these NOAs and find that they comply with the requirements of the 6'h Ed. (2017) Florida Building Code for use in this product. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will 1 acquire, a financial interest in any other entity involved in the testing or approval process of this product. Lucas Turner 2017-08-30 16:05+20:00 ''j!!!1llilll// AVq .��G E N SF..��Q,yi'. c No 58201 ;ON :1 L STATE OF 14U+ •......... Z;_7 8/28/2017 Lucas A. Turner, P.E. FL PE #58201 �r ' BCIS Home I Log In I User Registration I Hot Topic I Submit Surcharge I Stats & Facts ( Publications I Contact Us I BCIS Site Map Unks I Search F' Product Approval p r USER: Public User { Product Aooroval Menu > Product or Application Search > Application List > Application Detail FL # FL13010-R7 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR. Approvals bytg%Ot fall be,revie;ed and ratifi�i by the POC and/or the Commission if rrwwry. • • • • • • • • Comments • • , "" • • Archived soots* Q •••• • to a•••• Product Manufacturer •• •• Custom Window Systems Inc. •••• •••••• • ,,,,,� • Address/Phone/Email 1900 SW 44th Avenue : ` ' • Ocala, FL 34474 • • • • • • (352) 368-6922 Ext 291 • ; • `''' • jlathrop@cws.cc • • ` • Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Jay Lathrop jlathrop@cws.cc Jay Lathrop 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Jay Lathrop 1900 SW 44th Ave. Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Windows Fixed Certification Mark or Listing Keystone Certifications, Inc. Steven M. Urich, PE pJ Validation Checklist - Hardcopy Received Standard Year AAMA/WDMA/CSA 101/I.S.2/A440-05 2005 AAMA/WDMA/CSA 101/I.S.2/A440-08 2008 ASTM E1886-05 2005 ASTM E1996-05 2005 PA TAS 201/202/203 1994 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Pro ucts Method 1 Option A 08/27/2018 08/27/2018 09/06/2018 FL # Model, Number or Name Description • • •. 13010.1 PW-8150 PVC Fixed Window PW-8150 PVC Flg/Fin Fixed Window �•" "'�" Limits of Use •••••• Certification Agency 6ertifwete • ...... Approved for use in HVHZ: Yes FL13010_R7 C CA CA 1357 odf , Approved for use outside HVHZ: Yes FL13010 R7 C CA WL3-1362.odf • • • • • • Impact Resistant: Yes FL13010_R�CAC CAR I A§t562. df • ' • ' ' Design Pressure: N/A Quality Assurance Confi7arci Ex IrallorMate P • Other: PW-8150, 36" x 72" and 72" x 76" see installation 09/14/2019 ";''; • • • • • • •+ detail for DPs. Large Missile Impact. In HVHZ may only be •• Installation Instructions • • • • • • • • • • • • used u to 30ft above grade. Glass complies to ASTM E1300- P 9 P FL13010_ BZILC W S �33g� • ' 04. Verified By: Lucas A. T�rne? 51201 Created by Independent Third Party:'fhf • • • Evaluation Reports • • • .. • • • • LF 13010_BZAEvalReport4 3D.pd� " ' • Created by Independent Third Party: 12S" 13010.2 PW-8150 PVC Fixed Window PW-8150 PVC Flg/Fin Fixed Window, Continuous Head & Sill. Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL 1 _R7_C_CAC—CAR 138-261e2.p-d—f Approved for use outside HVHZ: Yes FL13010_g7_C_CAC_CAR 138-705e2.pdf Impact Resistant: Yes FL13010_R7_C_CAC_CAR 138-706e2.p-lf Design Pressure: +67.5/-67.5 Quality Assurance Contract Expiration Date Other: Large Missile, Dip = +/- 67.5 psf, Max. size 74 1/8" x 08/12/2019 72". Outer lite must be safety glass above 30 ft. in HVHZ. Installation Instructions Glass complies to ASTM E1300-04. FL13010_R7_II_CWS-510C.odf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: No Evaluation Reports FL1301 _R7_AE_EvalReport510C.pd Created by Independent Third Party: Yes 13010.3 PW-8300 PVC Fixed Window PW-8300 PVC FIg/Fin Fixed Window, 120" x 48" Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL13010_R7_C_CAC _CAR 138-258e2.12-df Approved for use outside HVHZ: Yes FL1 010_R7_C_CAC_CAR 138-481e2.pdf Impact Resistant: Yes FLl 1 _R7_C_CAC_CAR 138-482e2.pdf Design Pressure: +70/-70 Quality Assurance Contract Expiration Date Other: PW-8300, 120" x 48", DP = +/- 70 psf. Large Missile 04/09/2019 Impact. Glass complies to ASTM E1300-04. Installation Instructions FL13010_R7_II_CWS-373C.pd Verified By: Lucas A. Turner, P.E. FL PE #58201 Created by Independent Third Party: No Evaluation Reports FL13010_R7_AE EvalRepo rt373C.pdf Created by Independent Third Party: Yes 13010.4 PW-8300 PVC Fixed Window Series 8300 PVC Fixed Window, Large Missile Impact, 48" x 72"'unit size - DP55, or 72" x 76" unit size - DP67.5 (DP65 outside HVHZ) Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL13010_R7_C_CAC CAR 138-1093.pdf Approved for use outside HVHZ: Yes FL13010 R7_Q_CAC_CAR 138-1320 e2.pd Impact Resistant: Yes FL13010_R7_C_CAC_CAR 138-250.pd Design Pressure: N/A FL13010_R7 CAC CAR 138-274e2.�df Other: Sizes up to 48" x 72" unit size at design pressures of FL13010_R7_C_CAC_CAR 138-457.p_1f +/-55 psf, or in sizes up to 72" x 76" unit size at design FL13010_R7_C_CAC_CAR 138-465.pLf pressures of +/-67.5 psf in HVHZ or +/-65 psf outside the FL13010_R7_C_CAC_CAR 138-534.122f r, uX HVHZ, with max. glass daylight siies as shown in CWS-159E Glass complies to ASTM E1300-04. FC3010_R7_CCA _CAR 138-730e2.pdf FL13010 R7 C_CAC _CAR 138-739e2.pdf Quality Assurance Contract Expiration Date 03/16/2020 Installation Instructions FL13010_1_II_C W S-159E . pd Verified By: Lucas A. Turner, P.E. FL PE #58201 Created by Independent Third Party: No Evaluation Reports FL13 10_R7_AE_EvalRe ortl 9E.pdf Created by Independent Third Party: Yes Back M Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Cirright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement 11e1und Statement • • •••• •••••e Under Florida law, email addresses are public records. If you do not want your e-mail address released in response %%ptbl;-record reque t, do not send eleltronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 50.4874145•')yrsuant to Secfl 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide MA Arinent with an email addres�ijfpSyyve one. The emails provided may be used for official communication with the licensee. However email addresses aje pyiW1 j jecord. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. i1o�-determine if you are0a licensee U:�ej jha:ter 455, F.S., please click here . • • • • • • • • • Product Approval Accepts: 0000 • • • • • • • • ® W ® � 0 eCUec •••••• •••• ••••••• •• •• •••• •••••• Credit Card Safe . . . . ...... ...... . • .••••• .. • • •• • • •••• PICTURE WINDOW - LARGE MISSILE IMPACT - 37 1 /4" - MAX. OVERALL FLANGE WIDTH 36" MAX. UNIT WIDTH 31 13/16" — GLASS DLO A f- 73 1/4" B I B MAX. OVERALL FLANGE I I HEIGHT I I I O I I MAX.UNT I I HEIGHT I I I I 67 13/16" GLASS A TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS.......1 ARCHITECTURAL SHAPES...................2 SECTION VIEWS & GLAZING................3 EXTRUSIONS & B.O.M...........................4 ANCHOR SCHEDULE & NOTES ............ 5 INSTALLATION DETAILS.......................6 GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED 99mo TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND 1900 SW 44TH AVE. 1900 S E. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED FLORIDA IN ASTM E 1996 PER THE FBC. W W W CFLORI34474 2. GLAZING OPTIONS: (SEE SHEET 3) 8150 PVC "0". ARCHITECTURAL PES INCLUDE, BUT ARE 3 CONFIGURATIONOT PICTURE WINDOW LIMITED ON THOSE SHOWN ON SHEET 2.S: IMPACT 4. DESIGN PRESSURE RATING: -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND ¢ z 3 a z GLASS TABLES ASTM E-1300-04e01/09. -POSITIVE DESIGN LOADS BASED TESTED PRESSURE, WATER BL EST PRESSURE AND GLASS z a w J o K Z wINFILTRATON ASTM E-1300-04e01/09. w z Oo z} O- m 5. ANCHORAGE: THE 33 1/3 % STRESS INCREASE HAS NOT BEEN USED z z = m ¢ m w p O IN THE DESIGN OF THIS PRODUCT. SEE SHEET 6 FOR ANCHOR O ~ O (J ¢ _ � a N Z Z ~ DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD p z - I.- j ANCHOR CALCULATIONS. z O- 00. vi Hzwg0OOLLZ 6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT ¢ m ¢ O F � F Z REQUIRED. � ( C,opHY(30i 7. ALL FRAMES ARE FULLY WELDED. ¢ z wa O -1 N cn 8. SERIES / MODEL DESIGNATION PW-8150. O a W F0 (LM >- cn F m w 3 wa cr oHtln4ri 9. THE DESIGNATION X AND O STAND FOR THE FOLLOWING: 0 = FIXED SASH. 10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR J,4p`NGENS�TGQ��' LOCATION. J No 58201 t 11 Z LucasTurne r 2017-09-22 12:37-04:00 • • • • • • •• • •• • • • • • •• 0 ••• •• • 0 • • •• LOCATION MAX. UNIT SIZE DESIGN PRESS4JRE44ATING •••IMPAE}T RATING ALL 36" x 72" +/- 7 P$F ; . • NON-HVHZ 72„ x 76„ +/- 65•I?SF :' MISE MSSS11.9 IMPACT HVHZ +/- 67.5 PSF ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• 0 0 0 000 0 0 zz 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 GENERAL NOTES AND ELEVATIONS LAWN BY: DATE: AAJ 11 /25/11 VG l: REV.: CWS-433 D ALE: SHEET 1:20 1 OF 6 0 C:) FULL ELLIPSE (OVAL) FULL CIRCLE 1/2 CIRCLE 1/4 CIRCLE OCTAGON TRIANGLE TOMBSTONE TRAPEZOID NOTES: 1. SEE SHEET 5 FOR DETAILED ANCHOR INSTALLATION REQUIREMENTS. 2. THRU FRAME - MASONRY, WOOD OR METAL OPENING. THRU FIN - WOOD OPENING. 3. OVERALL SIZE MUST NOT EXCEED THE MAX. WIDTH AND HEIGHT OF RECTANGULAR WINDOW ON SHEET 1. 4. ANCHOR SPACING FOR ARCHITECTUAL FLANGE AND FIN WINDOWS MUST FOLLOW THE LAYOUTS SHOWN ON SHEET 5, WITH ANCHOR • ♦PA•IIgME•,SUFIED AtONG4H136LENOWN OF THE PRODUCT. • •• • • • • ••• • •• ••• •• • • • •• •• ••• • ••• ••• • •• • ••• • • • • • • • • • • • • • • • • • •• • • • •• • • ••• • • • • ••• • • • • • • • • • • • • ••• • • • ••• • • o Qmxm4s 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS CC 8150 PVC PICTURE WINDOW IMPACT < z 3 <z3 F- ow0wfo awpo o zozy0¢�m LL �w3zr-3mx z z=m<¢w00 0 OHO <_�¢ U UTn F-ZdFInD- co z p ::, } i¢u-W000z 92 ¢¢F>-D w p0¢co0wcnw Fx Uw O1cnF 00 wF 0 a— > a r a ¢ .w z2 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SHEET DESCRIPTION: ARCHITECTURAL SHAPES AAJ 11/25/11 VG M REV.' CWS-433 D :ALE: SHEET 1:1 20F6 SECTION VIEW A -A INTERIOR ALTERNATE FIN FRAME INTERIOR SECTION VIEW B-B ■ 7/8" OVERALL 3/16" ANNEALED or TEMPERED 1/4" AIR SPACE 7/16" LAMINATED 3/16" ANNEALED J9,: KURARAY PVB INTERLAYER 3/16" ANNEALED QUANEX DURASEAL IG SPACER PURFECT GLAZE "H" OR SIKAFLEX 552 21" GLASS BITE GLASS TYPE DP A +/- 75 B +/- 65 nx76 +/- 67.5 7/8" OVERALL 3/16" TEMPERED 1/4" AIRSPACE 7/16" LAMINATED 3/16" HEAT STRENGTHENED .084 KURARAY SENTRYGLAS INTERLAYER 3/16" HEAT STRENGTHENED ,QUANEX DURASEAL IG SPACER PURFECT GLAZE "H" OR SIKAFLEX 552 .W GLASS BITE .00 GLASS TYPE A • • : • : • : • • • GLASS TYPE B 1:1 • • •• • • • •• • • 1:1 ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • Qmmmsffl 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8150 PVC PICTURE WINDOW IMPACT a z 3: az3: F ow0 Qwoo w zOOz ¢�?� 0 ¢tn3>o¢3m u- 1-w z z=i¢¢w00 0 0coOV¢Pcoa rn Z a F— W H O W Z <Q0�-F0_ W O(n wrnC) JFr rnW a.a [n I- 0 co 0 wF0 p— zz 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 IEET DESCRIPTION: SECTION VIEWS AND GLAZING DETAIL IAWN BY DATE: AAJ 11/25/11 VG #: REV.: CWS-433 D 'ALE: SHEET 12 30F6 PARTS LIST ITEM PART# DESCRIPTION VENDOR MATERIAL 1 H-6025 SASH STOP MIKRON PVC 2 K6048 FIN FRAME MIKRON PVC 3 K6049 FLANGE FRAME HEAD MIKRON PVC 4 H-6049 FLANGE FRAME SILL MIKRON PVC 5 K6049 FLANGE FRAME LEFT JAMB MIKRON PVC 6 1 I -6049 FLANGE FRAME RIGHT JAMB MIKRON PVC 7 P-3113 SCREW SUPPORT FOR PVC 8 P-3352 SETTING BLOCK 85 DUROMETER 1/8" x 5/8" x 2" LG. FRANK LOWE RUBBER 10 P-4648 SIKAFLEX 552 OR HENKEL PURFECT GLAZE "H" SIKA / HENKEL 11 S-6064 GLAZING BEAD 7/8" O.A. I.G. MIKRON PVC 12 GLASS SEE SHEET 3 CARDINAL GLASS LINE ITEMS NOT USED 9 2 PVC FRAME, FLANGE - H-6049 3/16" 1 /2" ��— 3" O r 7 SCREW SUPPORT - P-3113 31 PVC FRAME, FIN - H-6038 FRAME CORNER CONSTRUCTION�) WINDOW SYSTEMS/MMLM 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC CORNER WELD (ALL SIDES) 8150 PVC SCALE 1:8 PICTURE WINDOW IMPACT ? 3 Qz� ow0 awco) o w zooz Q=�F O am—>Om3m LL z �w�zr3�= z=iQmwoo O U OHO Q=Fm Ucn~Za- Pcna o z—� zr�cn U- Q _OZUajz F--LL2OO I1_Z Q 2QOFFFO_ mm>cnU—Zcri O 0¢ 0 O o w w m w ZTw OJwI- a=¢>- 0 I, 0 wFa a ¢3w 16" 3/16' 15/16" 718• 11 7/8• 1 L ins' PVC GLAZING BEAD - S-6064 PVC FILLER, SASH STOP - S-6025 •• ••• • • • • • •• • •• • • • • ••• • •• ••• •• • • • •• •• ••• • ••• ••• • •• • ••• • • • • • • • • • • • • • • • ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 -IEET DESCRIPTION' BOM AND EXTRUSIONS RAWN BY: DATE: AAJ 11/25/11 NG#: REV.: CWS-433 D ,ALE SHEET 1:1 40F6 6' MAX. (TV 6' MAX. (fY 7 3/4" MAX. O.C. (TYP.) NOTES: ANCHOR LAYOUT - (FLANGE) DP +/- 65 PSF and +/- 67.5 PSF .E2 12" MAX.O.1 6' MAX. (fYI 6" MAX. (TYI INSTALLATION ANCHOR (TYP.) 12" MAX O.C. (TYP.) ANCHORLAYOUT- (FLANGE) DP +/- 75 PSF 4" MAX. (TY -2 4" MAX.(fY INSTALLATION ANCHOR (TYP.) 8" MAX O.C. (TYP.) ANCHOR LAYOUT - (FIN) ALL SIZES AND DPs 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. ANCHOR SPACING APPLIES TO ALL SHAPES (SEE SHEET 2) ALONG ALL FRAME EDGES. SILL ANCHOR SPACING SAME AS HEAD. WINDOW SYSTEMS E 19DO SW 44TH AVE. OCALA, FLORIDA 34474 NOTE WWW.CWS.CC 8150 PVC PICTURE WINDOW IMPACT a F i 3 az3 0.0 w w o p INSTALLATION o Lu LL Zww>-OMoz zm H w 3 z~ 3 ANCHOR (TYP.) Z O m_ Z m M Q¢ W 0 0 OI-0U))OVarv)(L Z r-OMOOLLZ > w- ¢ 20_ 11 L0M U)0 w 0 w zLnw 0 w~¢ a.mm 'L (L mad 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1 /4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 6. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHOR9SHALL 0 * BD U9ED4N 9UB3TR*TE6 WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 6. • • • • • • %: • • • • • • �•• • • �• 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEj)W9NTMLL1,.,_$IElQNU V:Oy E4)GKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQURE 1 X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE, INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1 X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3-9/16" FOR MASONRY, 1" FOR WOOD 44P W&L. • • • • • • • • 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEBROF REOORD AN; PISTALOED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 6. CONCRETE AND MASONRY-.SU:STR:T•ES?AA? N(;f Br CgAdkED.: • 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE•CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS), FMA/AAMA/WDMA 300(EXTERIOR DOORS) 000 • • • • • • • • • • • • • • • • • • % •• • • • % •• 000 0 0 0 000 0 • zz 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 ANCHOR SCHEDULE AND NOTES AAJ 11 /25/11 /G #: REV. CWS-433 D ALE: SHEET 1:1 50F6 TYPICAL HEAD ANCHORAGE MIN. EDGE DIST SUBSTRATE BY OTHERS / / / / / / SEE TABLE 1 SEE TABLE 1 PERIMETER SEALANT I INSIDE AND OUTSIDE MIN. EMBEDMENT INSTALLATION BY INSTALLER SEE TABLE 1 r///d I i SEE TABLE 1 SEALANT BEHIND 1/4' MAX. SHIM FLANGE BY INSTALLER INSTALLATION ANCHOR SEE TABLE 1 II Il I HEAD BY LANT NSTAL ERREW SEALANT BEHIND Ir 1/4" MAX. SHIM FLANGE BY INSTALLER Or1n n 1 MIN, EDMEt. PERIMETER SEALANT SEE TAABB LE i INSIDE AND OUTSIDE BYINSTALLER SUBSTRATE BY OTHERS SEE TABLE 1 MIN. EDGE DIST, SEE TABLE 1 VERTICAL SECTION 6 TYPICAL SILL ANCHORAGE MIN. EMBEDMENT SUBSTRATE BY OTHERS E/�QGL{, SEE TABLE 14111 SEE TABLE 1 WINDOW SYSTEMS III( IL/Ji( 1 /4" MAX. SHIM MIN. EDGE DIST. SUBSTRATE SEE TABLE 1 BY OTHERS 1900 SW 44TH AVE. 1/4" MAX. SHIM SEE TABLE 1 OCAA, FLORIDA 34474 MIN. EDGE DIST. WWW.CWS.CC �T�SEE TABLE 1 �— PERIMETER SEALANT INSIDE AND OUTSIDE BYINSTALLER SEALANT BEHIND FLANGE BY INSTALLER HORIZONTAL SECTION 6 TYPICAL JAMB ANCHORAGE TABLE I: APPROVED INSTALLATION FASTENERS FRAME TYPE SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. FLANGE CONCRETE (2.0 KSI MIN.) 3/16" ITW TAPCON 1-1/2 1-1/8" FLANGE HOLLOW OR GROUT -FILLED CMU (117 PCF MIN.) 3/16" IIW TAPOON T. 2" FLANGE CONCRETE (2.85 KSI MIN.) 3/16" ELCO ULTRACON 1" 1" FLANGE GROUT -FILLED CMU (ASTM C-90) 3/16" ELCO ULTRACON 1-3/4" 2-1/2' FLANGE 2X MIN. SOUTHERN PINE (G=0.55) 3116' I1W TAPCON OR ELCO ULTRACON 1-3/8" 7/8" FLANGE 2X MIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-3/8" 7/8" FLANGE 16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN) #10-16 HILTI KWIK-FLEX OR ITW TEKS SELF -DRILLING SCREW FULL THREAD THRU 0.060" 7/16" FLANGE 1/8" ALUM. (6063-T5 MIN.) OR 1/8" STEEL (33 KSI MIN.) #10 GRADE 5 SELF -TAPPING / DRILLING SCREW FULL THREAD THRU 0.125" 7/16" FIN 2X MIN. SOUTHERN PINE (G=0.55) #8 WOOD SCREW 1-1/2" YtHIMt I tH JI INSIDE AND OF BYINSTALLER N. EMBEDMENT KSEETABLE1 Tf' 0 8150 PVC PICTURE WINDOW IMPACT a 3. az PERIMETER SEALANT INSIDE AND OUTSI E Z W H O a k- W BYINSTALLER W 9 Z O Z ¢= H Q(n�} O Q� m INSTALLATION ANCHOR TABLE T Z =Qw0SEE Z2gp SEALANT BEHIND 0 O ~ 0 (j 4 2 I - Z I.= d FIN BY INSTALLER Z- Z I. O' HORIZONTAL SECTION Z O U Uj U H--,Mo LLU TYP6 ICAL FIN ANCHORAGE >_ < Q O F HEAD D AND SILL SIMILAR AINSTALLATION R FOR FIN INSTALTION m F' Z ( W OO¢NOWIoW wow W J yr a=O WH¢ wIrU)d- •• ••• • • •,• • • •• • • YD� \ =10FfZOI•ETASSECTION • • • • jjOX4F9WE INSTALLATION • • • • • YEAR AND SILL 96MILAR FOR BOX INSTALLATION •• ••• •• • • • •• FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE, • 4UP4r8AND INS LUDINC BOX-Ff'�1i ME �%LICATION IS ACCEPTABLE PROVIDED: • • - MiN. 1/6" FVI:T OF CONSTRUCTICLCIADE ADHESIVE CAULK IS APPLIED • INME AND OtlT311DLLD, FULL PERIMPTM, BY INSTALLER. • PRODUCT ANCHOAAGE IS IN ACCORDANCE WITH REQUIREMENTS AS SHOWN FOR FLANGE WINDOWS. ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • X� 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 INSTALLATION DETAILS SAWN BY: DATE: AAJ 11/25/11 NG f: REV.: CWS-433 D ''ALE: SHEET 1:2 60F6 Y URNER r ENGINEERING & CONSULTING, INC. Product Description: Series 8150 PVC Fixed Window, Large Missile Impact 1239 Jabara Ave. North Port, FL 34288 Ph. 941-380-1574 FBPE C.O.A. #29779 Evaluation Report 433D August 28, 2017 Manufacturer: Custom Window Systems, Inc. 1900 SW 441h Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 61h Edition (2017) Florida Building Code including the High Velocity Hurricane Zone. The product t esl jng standards performed are outlined below. • . . .... ...... Technical Documentation: ...... :""' ....:. 1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port,;F.L• • 2) Approval drawing CWS-433D, signed and sealed by Lucas A. Turner, P.E. • • • • ; • • :*see: . • • . 3) Test Reports NCTL-210-3566-1, -1 A, -1 B, and -1 C, and NCTL-210-4011-01 "1'A, -02, and 7A, ";'' . from National Certified Testing Laboratories, Orlando, FL signed and sealecrg; "arard J. :"• ""' .... Ferrara, P.E., with testing AAMA/WDMA/CSA 101/I.S.2/A440-.0./� ...... performed: �•;ASTM E1886-05 and ASTM E1996-05/09 and TAS 201 202 203 1994 •• • 4) Supplemental Calculations to support CWS-433D, signed and sealed by Lucks A..Turner;PI.!.* . .. .. . . Installation: Units must be installed according to approval document CWS-433D. 0000 Limitations of Use: This product: • May be used in O config. in sizes and with glass DLO sizes as shown in CWS-433D • Achieves a design pressure of +/-75 psf in unit sizes up to 36"02"with 3/16Ann (or Tempered) — Air — 3/16Ann-.105PVB-3/16Ann glass minimum. Achieves a design pressure of +/-67.5 psf in unit sizes up to 72"x76" with 3/16 Tempered — Air — 3/16HS-.090SGP-3/16HS glass minimum. • Is impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires the use of tempered outboard glass above 30 ft of grade in HVHZ • Requires Kuraray (Dupont) PVB Interlayer per Miami -Dade NOA #16-1117.021 in DP 75 units up to 36"x72", and requires Kuraray (Dupont) Sentry Glas Interlayer per Miami -Dade NOA 14- 0916.11 t in DP 67.5 units up to 72"x76" • Requires Quanex (Mikron) white rigid PVC framing per Miami -Dade NOA #17-0206.10t t I have evaluated the materials in these NOAs and find that they comply with the requirements of the 6" Ed. (2017) Florida Building Code for use in this product. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. 1 do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. Lucas y -+;' No 58201 :-P i Turner " * � * = * _= 2017-08-30 ° ' a :� : STATE OF . ki: $/28/2017 16:15+20:00 ',�.�••.� P.: .` •,�ccs.� oq; o. p��.� Lucas A. Turner, P.E. ��hs!0NA4Eq•�` FL PE #58201 6! BCIS Home In User Registration,, `;,, � � .//'•'',,,.,..1��'•',,i - Log I Hot Topics Submit Surcharge I Stats & Facts Publications ( Contact Us I BCIS Site Map I Links I Search I F 'a mProduct Approval i r USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) FL16736-R2 Revision 2017 Approved 0 Custom Window Systems Inc. 1900 SW 44th Avenue Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Kevin Pine kpine@cws.cc Jay Lathrop 1900 SW 44th Ave Ocala, FL 34474 (352) 368-6922 Ext291 jlathrop@cws.cc Arturo Monteverde 1900 SW 44th Ave Ocala, FL 34474 (352)368-6922 Ext221 amonteverde@cws.cc Windows Horizontal Slider sees sees•• • • ••e• • sees • • • e••e•• • • •. sees .sees• sees•• sees•• sees• sees•. • • • •.sees sees•• Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer (1 Evaluation Report - Hardcopy Received Lucas A. Turner PE-58201 Keystone Certifications, Inc. 07/21/2020 Steven M. Urich, PE ® Validation Checklist - Hardcopy Received FL16736_R2_COI EvalReport871C.pdf Standard Year AAMA/ W DMA/CSA/ 101/I . S. 2/A440-08 2008 ASTM E1886-05 2005 ASTM E1996-09 2009 PA/TAS 201/202/203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 09/28/2017 09/29/2017 10/03/2017 12/12/2017 umma of ucts FL # Model, Number or Name Description • • • • • • • • • • • • 16736.1 HS-8200 PVC Horizontal Slider HS-8200 PVC Horizontal Slider IMPAf f-?-; c 6� I•OX. •••••i •' '•.• •. Limits of Use Installation Instructive • • • • • Approved for use in HVHZ: Yes • FL16736_g2_jLCWS_S71Godf • • . : "• 0 Approved for use outside HVHZ: Yes Verified By: Lucas A. lillge"r�'$201 ; *,so Impact Resistant: Yes **:so* Created by Independen tt Ihlrrq Party: Yeis� 0.0 Design Pressure: +60/-60 . • • 0 Evaluation Reports • . % Other: Large Missile, 74" x 63", DP +/- 60 psf. Outer lite in • • • •; • FL16736_R2 AE Evalaoft'$71C.pdf o I.G. must be safety glazed when used above 30 ft. in HVHZ. Created by IndependeprT§it4 Party: Yes• • • Glass complies to ASTM E1300-04. • • • • • • • • • • 16736.2 HS-8200 PVC Horizontal Slider HS-8200 PVC Horizontal•91ide; IMPA f% 1•l' x 63"! XOX Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16736_R2_II_CWS-869C.pdf Approved for use outside HVHZ: Yes Verified By: Lucas A. Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +60/-60 Evaluation Reports Other: Large Missile, 111" x 63", DP +/- 60 psf. Outer lite in F 1L 6736_U_AE_ valRel2ort869C.12d I.G. must be safety glazed when used above 30 ft. in HVHZ. Created by Independent Third Party: Yes Glass complies to ASTM E1300-04. Back E Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Coo ri ht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ®�in E Credit Card Safe HORIZONTAL SLIDER - LARGE MISSILE IMPACT 751/4" MAX. OVERALL FLANGE WIDTH 74" MAX. UNIT WIDTH GLASS DLO-7 -- -- 1414- I -- I - 64 1 /4" ' MAX. FLANGE B HEIGHT UNIT ��II O IIIII HEIGHT X I I 58 13116" GLASS TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS SECTION VIEWS & GLAZING DETAILS....2 EXTRUSIONS & B.O.W ..............................3 ANCHOR SCHEDULE & NOTES................4 INSTALLATION DETAILS ...........................5 No —33" GLASS DLO — 36 5/16" MAX. SASH WIDTH B 59 9/16" MAX. SASH GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED 99imm TO COMPLY WITH THE FLORIDA BUILDING CODE (FBC), CURRENT EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND 1900 SW 44TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED OCALA, FLORIDA 34474 IN ASTM E 1996 PER THE FBC. www.cws.cc 2. GLAZING OPTIONS: (SEE SHEET 2) 8200 PVC 3. CONFIGURATIONS: "OX "XO°. HORZ. SLIDER 4! DESIGN PRESSURE RATING: IMPACT -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04e01/O9. -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES w o ¢ w O ASTM E1300-04e01/Og z O w 5. ANCHORAGE: THE 33 1 /3 % STRESS INCREASE HAS NOT BEEN USED w 0 LL zOz ¢_?r a m 3 > O ¢ 3. m ¢ ~¢ o IN THE DESIGN OF THIS PRODUCT. SEE SHEET 5 FOR ANCHOR z z = m w O DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD O O � O ¢ _ ¢ m H a ANCHOR CALCULATIONS. 0 z c- z Z j ~ 6. PRODUCT APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT 4 U� z w i p O LL z REQUIRED. THE IMPACT ROTARY LOCKS ARE INTENDED TO BE LEFT ¢ < ¢ O w F m O UNLATCHED DURING NORMAL OPERATION OF THIS PRODUCT, BUT F ¢ ¢ } O ¢ MUST BE ENGAGED PRIOR TO EXPOSURE TO HURRICANE WINDS AND w O (n o w CO w FLYING DEBRIS. ¢ a z m w O -j U) H wry woxU) 7. ALL FRAMES AND VENTS FULLY WELDED. SMALL JOINT SEAM SEALANT ¢ _ a Cr3 a USED AT FIXED MEETING RAIL AND HEAD/SILL. LL ~ �Wunrrr MODEL DDESIGNATION 9. THE DESIGNATION AND O STAND FOR THE FOLLOWING: `C�y 0..0 X = OPERABLE SASH, O = FIXED SASH t" No 58201 : T 10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR "� LOCATION. S STATE OF , 41 1.11. EXTERNAL WEEP SLOT = 1 /4" x 1" LOCATED 4" FROM BOTH ENDS. SOTS :& n.. � 0It f"F •• ••• • • • • • •• • •• • • • • ••• • •• ••• •• • • • •• G• • • • MAX. UNIT SIZE DESIGN PRESSURE RATIN IMRA T TM • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • LucasTurne r 2017-09-22 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 13:58-04:00 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 GENERAL NOTES AND ELEVATIONS ADE 10/10/13 JG#. REV.: CWS-871 C 'ALE: SHEET 1:15 1 OF5 INTERIOR SECTION A -A SECTION C-C ALTERNATE FIN FRAME INTERIOR SECTION B-B NOTE: FIXED LITE AT HEAD AND SILL IS SIMILAR. HEAD IMPACT HOOK (TYP.) MIDSPAN OF SASH (ITEMS 35 & 36) ROTARY LOCK (fYP.) ONLY ENGAGED PRIOR TO HURRICANE FORCE WINDS. LOCATED AT THIRD POINTS X I (ITEM 27) •• HEAD IMPACT HOOK AND • • • • • • JAMB ROTARY LOCK LOCATIONS* • • 000 • • • 1:20 : % • • i i • • AS&T4E A • • • • • 1:10 ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • 7/8" OVERALL 1/8" ANNEALED or TEMPERED 7/16' AIRSPACE 5/16' LAMI 1/8' ANNEALED AM DUPONT PVB INTERLAYER 1/8" ANNEALED PURFECT GLAZE "H" SIKAFLEX 552 —1/2" GLASS BITE QUANEX DURASEAL IG SPACER \YWlii" om j] WINDOW SYSTEMS u 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS.CC 8200 PVC HORZ. SLIDER IMPACT < - 3 <z3 F Owo awoo W zOOz m=—L 0 aw1>-0M3'm ILL Fw ZF-3:2= Z zzm<mwoo OHO <=r¢ Uv)�-z Pc1D_ o z—�—zF�v� Z OOOvi - < H�w.Ou-z ¢ a30W—m0— ¢ m m W¢ r>w U ZWQ0¢ La0?vjO W to �cc �¢O wQ W� a L fr IL No 58201 STATE OF 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 IEET DESCRIPTION: SECTION VIEWS AND GLAZING DETAIL IAWN BY: DATE: AIDE 10/10/13 IG #: REV.: CWS-871 C ALE: SHEET 1:2 20F5 PARTS LIST ITEM PART/ DESCRIPTION VENDOR MATERIAL 1 H-1497 Reinf. Sash Meet. Rail Keymark Alum 2 H-1699 Reinf. S.B.R./S.S.R. Keymark Alum 3 H-1836 Meet. Rail, Fxd. Keymark Alum 4 H-6052 Sash Top/Bot. Rail Mikron PVC- -5 H-6048 Main Fr., SH, w/ Fin., PVC Mikron PVC 6 1 H-6050 11ash Meet. Rail, PVC Mikron PVC 7 1 H-6051 JSash Side Rail, PVC Mikron PVC- -8 H-6049 Main Fr., SH, w/Flg., PVC Mikron PVC 9 P-3029 Screen Pull Tab Summit 10 P-3033 Screen Spring, SS Hurley 11 P-3113 Screw Support, PVC Team Plastic Rubber 12 P-3218 Screen Frame Allmetal RollForm 13 P-3228 Screen Spline, .155 Dia., Blk. Dapa 14 P-4754 IScreen Frame Corner Key Allmetal Nylon 15 P-3342 Seam Sealer, SM-5504 Schnee Silicone 16 P-3352 Set. Blk., 85 Dur., 1/8" x 5/8" x 2" Lg. FrankLowe Rubber 17 P-3429 Wstp., 0.270 x .187 back FinSeal, Gr Ultrafab 18 P-3539 #8 x 3/4" Square TEK 2 Zinc Fastenal Steel 19 P-4730 #8 x 1/2" Truss PH TEK 2 Zinc Fastenal Steel 20 P-3752 Cap Plug, 1/2" Hole M&M Nylon 21 P-3783 or P-5250 Spring Lock, Impact, PVC Interlock 22 P-4779 Roller, Tandem M&M Nylon 23 P-4051 #8 x 1 1/4 Ph FH TEK, Wht. Fastenal Steel 24 P-4069 Keeper, Impact, PVC Interlock 25 P-4479 Weep Cover w/ Flap M&M Nylon 26 P-4638 #8 x 2 1/2 Ph Truss SMS Ajax Steel 27 P-4958 Rotary Lock Sullivan Zinc 28 P-4952 Keeper, Rotary Lock Sullivan Zinc 29 P-4959 Wstp., 0.420 x .187 back FinSeal, Gr, Ultrafab 30 P-4633 Barrel Fastener Fastenal Steel 31 S-1112 Reinforcement, Head Keymark Alum 32 S-1498 Reinf. S.B.R./S.S.R, Keymark Alum 34 S-1776 Roller Track Keymark Alum 35 S-1999 Frame Hook, Head, Impact Keymark Alum 36 S-2000 Panel Catch, Head, Impact Keymark Alum 37 S-6005 Anti Lift Mikron PVC 38 S-6013 Scm. Adapt., w/ Nib, PVC Mikron PVC 39 S-6014 Scrn. Adapt., PVC Mikron PVC 40 S-6063 Fixed Rail Cover Mikron PVC 41 S-6064 Glazing Bead Mikron PVC 42 GLASS SEE SHEET 2 CARDINAL GLASS 43 1 1Purfect Glaze "H", SikaFlex 552 1 Henkel / Sika ISilicone 3 1/8"� e J - 2 11 /16"L3 ill 6" PVC FRAME FLANGE-6049 3 118" 1 1/2" 3 5 9/16" Q 1/16' 21/8" 1/16' I� 1" FIXED RAIL - 1836 PVC FRAME FIN-6048 2 3/16" 1 15116" �{ 1 3116"�{ 9/16' s I 14 IL 7 40 1 5I/8" 1 5/8• , S116" 1116" I q 1/16" q 1/16" ,/16^ PVC SASH MTG. RAIL-6050 PVC SASH SIDE RAIL-6051 PVC SASH TOPBTM RAIL-6052 PVC FIXED RAIL COVER - 6063 0 3/16" O 1 5/16" 35 78" 1/16" PLAN VIEW-1999 HEADIMPACTHOOK -1999 0 3/16" O L 6' 5/8 T- 36 5/8" L PLAN VIEW-2000 r 3/16' L 3' 1/2' 11 SCREW SUPPORT-3113 LINE ITEMS NOT USED: NOTE: ALL EXTRUSIONS ARE ALUMINUM 6063-T6 UNLESS OTHERWISE NOTED. 33 CORNER CONSTRUCTION CORNER WELD (ALL SIDES) 1:8 M.- �- -. �E; FIXED MEETING RAIL SCREWED TOGETHER WITH OUTERFRAME 1:8 5 3/4" /--� -j�--I- � � I 2 1" 1 15, 16" L L SASH MTG. RAIL-1497 SASH REINF. - 1699 �{I 3/16"� 3/4" j� L'' I 34 1ns" Ins" S.B.R./S.S.R. - 1498 ROLLER TRACK - 1776 l4r 7/8" 1 41 7re 9/1►6T31 • J� 1/16" PVC GLAZEBEAD - 6064 GLAZE BEAD - 1112 PANEL IMPACT CATCH - 2000 1/2. /8" I 3/8• 1 5/16" 3 L 38 1/16" 1116• • • • • • • • • • • • • • • Fy/•CS•CR♦tEN CATCH - 6013 • • PVC ANTI -LIFT - 6005 • •• • • • • ••• • 39 1/16" • • • • • • • • • PVC S�VJN SUPPORT - 6014 •• • ••• • • • • • • • • • • • • • • • • • •• • • • •• • • ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • 1900 SW 44TH AVE. OCALA, FLORIDA 34474 W W W.CWS CC 8200 PVC HORZ. SLIDER IMPACT Z 3. 3 az0 W ZJOZ ¢=ZW u- 1,-W�zl�-3gx z z=iaa=WOp O Om�OaPina. yZ Z O Z)-Zno- Y Q3:0W—=O_ zNW MM BCD O W~¢ word a a M�nW- zZ- 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH.941-380-1574 BOM AND EXTRUSIONS I ADE 10/10/13 ✓G R: REV.: CWS-871 C :ALE: SHEET 12 3OF5 121/2' MAX.0. 6' MAX. (TYP.) 6' MAX. (TYP.) 17" MAX. O.C. (TYP.) NOTES: ANCHOR LAYOUT - (FLANGE) 2 INSTALLATION ANCHOR (TYP.) 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. 4" MAX. (TYP.)�t 8" MAX. O.C. (TYP.) 4' MAX. (TYI 8" MAX. O.C. (TYP.) ANCHOR LAYOUT - (FIN) WINDOW SYSTEMS u 1900 SW 44TH AVE. OCALA, FLORIDA 34474 IOTE2 WWW.CWS.CC 8200 PVC INSTALLATION HORZ. SLIDER ANCHOR (TYP.) IMPACT 2. SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 1/4". USE SHIMS WHERE SPACE GREATER THAN 1/16" IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 5. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. •• ••• • • • • • •• 5. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS:SHALL NO* BE WWD4N SUB&TRRTE6 WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 5. • • • • • • • + • • • 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS, EMBEDMEVSHAL V 130014D WfOOD 9UCKS *IF!USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REOURE 1 X WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1 X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 3" FOR MASONRY, 1" FOR WOOD ANp RAETAL.: • • •: •: • • • • •• • ••• • • • • 8. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RE010RD •.NL•INWAPLED T(PTRAINSFER VAND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 5. CONCRETE AND MASONRYSU SSTRRTtS MAY NOr BE CRACKED. • • • • 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMA/WDMA 250(BOX WINDOWS), FMA/AAMAANDMA 300(EXTERIOR DOORS) • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• 0 0 Q R. ¢Z� P O w 0 Q w Op 0 _0 ZOW?>O¢Zm w F-w ZF3g2 Z ZSma¢w0O O OHO a ¢ z ��a Z Z0 0j—Z?Utn > ¢�:Ow-mo_ mcc 3'0� ¢ ZSnw�OJlnH a 0 w�0 M1: a: w ¢¢ a F- a ¢�a z z- 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 ANCHOR SCHEDULE AND NOTES ADE 10/10/13 ✓G # REV.: CWS-871 C 'ALE: SHEET 1:20 40F5 TYPICAL HEAD ANCHORAGE MIN. EMBEDMENT SEE TABLE 1 SUBSTRATEBYOTHERS QMOMM MIN. EDGE DIST. 1/4" MAX. SHIM SEE TABLE 1 MIN. EDGE DIST. SUBSTRATE 1900 SW 44TH AVE. SEE TABLE 1 SEE TABLE 1 BY OTHERS SEE TABLE 1 OCALAwww. FLORIDA 34474 SUBSTRATE BY OTHERS 1/4" MAX. SHIM WWW.CWS.CC SEE TABLE 1 MIN. EDGE DIST. MIN. EMBEDMENT SEE TABLE 1 PERIMETER SEALANT SEE TABLE 1 8200 PVC BYINSTALLER ANCHOR INSIDE AND OUT SEE TABLE 1 HORZ. SLIDER M MIN. IN EM. SEALANT BEHIND SEE TABLEDMENT IMPACT FLANGE BY INSTALLER 1/4" MAX. SHIM 0 a 3. azo LT PERIMETER SEALANT Z W Lu Op Q W o W PERIMETER SEALANT BY INSTALLER BYNSTALLER INSIDE AND OUT W 0 Z O Z = F Q to 3> O a:3. 6-3 SIDE AND OUT INSTALLATION ANCHOR Z Z= i a Cr W p p INSTALLATION ANCHOR SEALANT BEHIND FLANGE BY INSTALLER SEE TABLE 1 SEALANT BEHIND O o O F- 0 U a = I.-Ir rn to Z ~ fD a Z z� Z)� SEE TABLE 1 FIN BY INSTALLER Z O C1' � U ZOO HORIZONTAL SECTION (�C1 HORIZONTAL SECTION Q F- LL M u- U O}~ F O Z 5 TYPICAL JAMB ANCHORAGE 5 TYPICAL FIN ANCHORAGE cci¢ r HEAD AND SILL SIMILAR FOR FIN INSTALLATION H ¢ Q F > 0 3 O,6 W O0=(n0wU)w tl t'na- Fr z OJ(gF a cr 0¢ O u/�Q Wy L 1/4" MAX. SHIM d ¢ d SEALANT BEHIND FLANGE BY INSTALLERj OREIV,F*PERIMETERSEALANT MIN. EMBEDMENTBYINSTALLERSEE 201 t 1 INSIDE AND OUTSTATE TABLE 1 w OFSUBSTRATE BY OTHE �T'•.�� Or, y�iFS SEE TABLE 1 MIN. EDGE DIST. SEE TABLE R 1 ";.-?/ONAsoll � Ep�`�` q VERTICAL SECTION 5 TYPICAL SILL ANCHORAGE TABLE 1: APPROVED INSTALLATION FASTENERS FRAME TYPE SUBSTRATE TYPE ANCHOR TYPE MIN. EMBEDMENT MIN. EDGE DIST. FLANGE CONCRETE (2.0 KSI MIN.) 3/16" RW TAPCON 1-1/2" 1-1/8" FLANGE HOLLOW OR GROUT -FILLED CMU (117 PCF MIN.) 3/16" IIW TAPCON 1" 2" FLANGE CONCRETE (2.85 KSI MN.) 3/18" ELCO ULTRACON 1' i' FLANGE GROUT -FILLED CMU (ASTM C-90) 3/16" ELCO ULTRACON 1-1/4" 2-110 FLANGE 2X MIN. SOUTHERN PINE (G=0.55) 3116' IIW TAPCON OR ELCO ULTRACON 1 3/8" 7/8" FLANGE 2X MIN. SOUTHERN PINE (G=0.55) #10 WOOD SCREW 1-3/8" 7/8" FLANGE 16 GAUGE (0.060") MIN. STEEL STUD (33 KSI YIELD MIN) #10-16 HILTI KW IK-FLEX OR ITW TEKS SELF -DRILLING SCREW FULL THREAD THRU 0.060" 7116„ FLANGE 1/8" ALUM. (6063-T5 MIN.) OR 1/8" STEEL (33 KSI MIN.) #10 GRADE 5 SELF -TAPPING ! DRILLING SCREW FULL THREAD THRU 0.125" 7116 FIN 2X MIN. SOUTHERN PINE (G=0.55) #8 WOOD SCREW 1-112" 1/2" "RI"INIR WALIRNT—•ter • • • \ • BY INSTALLED• • • • • • • •INSIDE �Nt O� • • • • • • • s • -D TiQRIZOATAL SECTION s • *0: • • • 5 BOX FRAME INSTALLATION HEAD AND SILL SIMILAR FOR BOX INSTALLATION FLANGE REMOVAL NOTE: PARTIALLY OR FULLY REMOVING THE FLANGE, • •& ItrQND IN(:-FItF& Ar%CATION IS ACCEPTABLE PROVIDED: • • • - Mlk. 1/40 FILDLE F OP CCONWRUOS�TIOMGGRADE ADHESIVE CAULK IS APPLIED 0,9 • • - PRODUCT ANCHORAGES IN ACCORDANCE WITH REQUIREMENTS AS SHOWN FOR FLANGE WINDOWS. • • • • • • • • • • • •• s• • • • •• •• ••• 0 • 0 000 0 0 7sz— 9/22/2017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 INSTALLATION DETAILS I AIDE 10/10/13 VG I: REV.: CWS-871 C :ALE: SHEET 1:2 50F5 y T URNER ENGINEERING & CONSULTING, INC. 1239 Jabara Ave. North Port, FL 34288 Ph. 941-3 80-1574 FBPE C.O.A. #29779 Evaluation Report 871C August 29, 2017 Product Description: Series 8200 PVC Horizontal Slider Window, Large Missile Impact (HVHZ), XO or OX 74"x63" unit size with design pressures of +/-60 psf (Fin or Flange window) Manufacturer: Custom Window Systems, Inc. 1900 SW 441h Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of U.6th Edition (2017) Florida Building Code including the High Velocity Hurricane Zone. The product Tasting' .....0 standards performed are outlined below. '..' : . . Technical Documentation: •••••• 1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North P.M,•PL :'. '. 2) Approval drawing CWS-871C, signed and sealed by Lucas A. Turner, P.E. 00 ' •' 3) Test Reports NCTL-210-3 887-1, -1 A, -2, and -2A, by National Certified Test' • eborat ". Orlando, FL, signed and sealed by Gerard J. Ferrara, with testing performed;•T.4$.201, 202,.203 `94, ASTM E 1886 `02/04/05, ASTM E 1996 `04/06/09, and AAMA/WDMA/CS4 101/I.S.2/A440 `08 0 . 4) Supplemental Calculations to support CWS-871 C, signed and sealed by Lucas 4. lurneri PbB.• � .' • ��:�•. • .• ....:. • � � • � • .... Installation: Units must be installed according to approval document CWS-871C. Limitations of Use: This product: • May be used up to the sizes and daylight openings indicated in CWS-871 C • Achieves design pressures of +/-60 psf • Is Large Missile impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires Kuraray (Dupont) PVB Interlayer per Miami -Dade N.O.A. 16-1117.02t • Requires Quanex (Mikron) white rigid PVC framing per Miami -Dade N.O.A. 17-0206.1 Ot t I have evaluated the materials in these NOAs and find that they comply with the requirements of the 6th Ed. (2017) Florida Building Code for use in this product. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. Lucas Turner 2017-08-30 16:09+20:00 �♦y NOREW ♦�♦♦V� ,.y�C E N SF•.�,��i y No G9 ; STATE OF ���►: 07_� 8/29/2017 Lucas A. Turner, P.E. FL PE #58201