RC-16-2286 (2)Water and Sewer
PO Box 330316 • 3071 SW 38 Avenue
MIAMI•DADE Miami, Florida 33233-0316
® T 305-665-7471
miamidade.gov VERIFICATION FORM
THIS FORM IS NOT VALID WITHOUT A PAID INVOICE AND EXPIRES ONE YEAR FROM THE DATE ON FORM
ATLAS PAGE: F-7 INV#:
40813 FORM #: 201767095 DATE:
NAME OF OWNER: PROPHET SFR / M2017001518
PROPERTY ADDRESS: 1190 NW 101, STREET
PROPOSED USAGE /
NO. OF UNITS:
REPLACES: PREVIOUS
USAGE / NO. OF UNITS:
PROPERTY LEGAL:
10/17/2017
SINGLE FAMILY RESIDENCE ADDITION PER PLANS.
SINGLE FAMILY RESIDENCE PTX 1940. CCB# 6280984200
i1 53 41 BONMAR PK ADD A RE SUB PB 24-71 W75FT LOTS 1 TO 4 INC BLK 3 LOT SIZE 75.000 X
1108 73R-285545 OR 13048-644 1086 1
I
FOLIO NUMBER: 11-3101-023-0170—� GALLONS PER DAY INCREASE: L_0
PROPOSED FLOW: 2201 PREVIOUS SQUARE FOOTAGE: 1,117 ❑d NEW CONSTRUCTION
PREVIOUS FLOW: 220i PROPOSED SQUARE FOOTAGE: 2,102 ❑d INTERIOR RENOVATION
ADOPTED FLOW: p ❑CRITICAL HABITAT FEWER ONLY
THIS IS TO CERTIFY THAT THE MIAMI-DADE WATER AND SEWER DEPARTMENT DOES HAVE A(N) _2_ INCH
WATER MAIN ABUTTING THE SUBJECT LEGALLY DESCRIBED PROPERTY. WE ARE WILLING TO SERVE THE SUBJECT
PROPERTY, (OR, IF "WILL HAVE", UPON PROPER CONVEYANCE AND PLACEMENT INTO SERVICE OF WATER FACILITIES
BY THE DEVELOPER UOPER AGREEMENT WITH THE DEPARTMENT, (AGREEMENT ID # N/A) SUBJECT TO PROHIBITIONS
OR MSTRICTIONS OftOVERNMENTAL AGENCIES HAVING JURISDICTION OVER MATTERS OF WATER SUPPLY OR
NEW BUSINESS
TURETOF REPRESENTATIVE
Nancy Cobb - New Business
Representati111,�
AUTHORIZED BY
VF=$30.00 PRESSURE TEST PASSING MEMO DTD 10-26-17. MAX MTR 5/8"
THIS IS TO CERTIFY THAT THE MIAMI-DADE WATER AND SEWER DEPARTMENT DOES NOT HAVE A(N) _ -_ INCH
GRAVITY SEWER MAIN ABUTTING THE SUBJECT LEGALLY DESCRIBED PROPERTY. WE ARE WILLING TO SERVE
.&THE SUBJECT PROPERTY, (OR, IF "WILL HAVE", UPON PROPER CONVEYANCE AND PLACEMENT INTO SERVICE OF SEWER
SEWER FACILITIES BY THE DEVELOPER UNDER AGREEMENT WITH THE DEPARTMENT, (AGREEMENT ID # N/A).
SUBJECT TO PROHIBITIONS OR RESTRICTIONS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION OVER MATTERS
OF SEWAGE RE OF ALL SEWAGE FLOWS INTO THE
T E T
BAINED%A�DE R.M.THE AN PATDDAILYWATER AND/OR FLOW FOR THISPROJECT WILL E: NO
ONS [01 NS 4ERAY I.NeREASE.
NEW BUSINESS
OF REPRESENTATIVE
Nancy Cobb - New Business
Representative
AUTHORIZED BY
Subject to RER terms & conditions set forth in Consent Decree (Case No.1:12-CV-24400-FAM)
or DOH Onsite Sewer Treatment & Disposal Rules & Statutes
THIS VERIFICATION LETTER CERTIFIES THE AVAILABILITY OF A WATER AND/OR SEWER MAIN ONLY, AND IT DOES NOT
GUARANTEE THE EXISTENCE OF A WATER SERVICE LINE OR OF A SEWER LATERAL WITH SUFFICIENT DEPTH TO SERVE THE
PROPERTY. FOR ADDITIONAL INFORMATION CALL 786-268-5360. SHOULD IT BECOME NECESSARY TO INSTALL A SERVICE LINE
AND/OR A SEWER LATERAL WASD REQUIRES THAT THE DEVELOPER RETAINS SERVICES FROM DESIGNERS AND
CONTRACTORS WITH SKILL SETS FOR DESIGNING, BUILDING AND CONNECTING TO PUBLIC WATER AND SEWER SYSTEMS.
CONTACT NAME: RAQUEL SCAF
CONTACT PHONE: (305) 281-4490
AUTHORIZED BY:
Printed On: 11/3/2017 NB: Nancy Cobb
10:06:50 AM PR:
�/ p _ 17
i
1t
9
k.
4, Y
MUEngineers, Inc.
3440 NE 121h Avenue
Oakland Park, FL 33334
Phone: (954) 324-4730
CA#:29348
www.MUEneineers.com
October 10, 2017
Miami Shores Village
Building Department
10050 NE 2"d Avenue
Miami Shores, FL 33138
Attention: Mr. Ismael Naranjo, B.O., CFM
Reference Project Name:
Project Address:
MUE Project #:
Permit Number:
To Whom It May Concern,
Ricard Prophets Residence -Addition
190 NW 101' Street, Miami Shores, FL 331SO
MUE16030301
16-2286
Please find below our response to the structural related permit comments dated 09/19/17 prepared by
the City of Miami Shores Village Building Department.
Comment#: 4
Comment: Provide signed and sealed by FL Arch or Eng structural calculations to include but
not be limited to the following elements: A) Foundations -both isolated and continuous wall
footings.
MUE Response: Structural calculations are being provided with this response to the review
comments.
Comment#: 5
Comment: Structural load calcs required to comply with FL administrative code section 61G15-
23.Original signature, Date and seal are required on both sets.
MUE Response: Structural calculations are being provided with this response to the review
comments
Comment#: 7
Comment: Provide two copies of special inspector form, fully executed for: A). reinforced
masonry per section 2122.4 of FBC 5th Edition (2014) Code. B) Miami Dade County
Administrative Code, Article 11, Section 8-22: 1) soil compaction 2) prefab truss erection of
trusses over 35ft long or over 6 foot high per
MUE Response: Copies of the special inspector form are being provided with this response to
the review comments.
Comment#: 4
Comment: Foundation analysis uses soil bearing of 2,500 PSF, specification for soil statement
only certify bearing of 1,500 PSF. Must revise Cal'c accordingly.
THOROUGH, DETAILED AND COST EFFICIENT ENGINEERING DELIVERED IN A TIMELY MANNER
FI
h
On ineers, Inc
MUE Response: Please see the calculations provided with this response to the review comments
and the structural notes. The foundations were designed for a soil bearing pressure of 1,500psf
as specified.
Sincerely,
Digitally signed by Marcus Unterweger
DN: C=US, E=munterweger@MUEngineers.com, OU--"FL
Marcus Unterweger P.E. #: 63860", 0="MUEngineers, Inc.", CN=Marcus
Unterweger
Date: 2017.10.10 18:54:55-04'00'
Marcus Unterweger, P.E., S.I., LEED AP
President
Page 2 of 2
t
MUEngineers, Inc.
3440 NE 121h Avenue
Oakland Park, FL 33334
Phone: (954)324-4730
CA#:29348
www.MUEneineers.com
October 20, 2016
Prepared For:
NO
� titi� H
Prepared By:
U9 ngi neers, Inc.
MUE PN: MUE16030301
Structural Calculations, Notes and Details
ProphetsResidence
190 NW 101st. Miami Shore, FL 33150
MU angineers, Inc
3440 NE 121h Avenue
Oakland Park, FL 33334
Phone: (954) 324-4730
Fax: (954) 653-4170
www.MUEngineers.com
License No. 29348
``
��. S �. UNTFq''A _�..
63860 •••F�,'�o
Q ST TE OF
O N
�0.1GU�S �v�W�t
1 •�'tw��e�� O
Ft QE 63�CD
THOROUGH, DETAILED AND COST EFFICIENT ENGINEERING DELIVERED IN A TIMELY MANNER
ngineers, Inc
Index
Page
Wind Load ASCE 7-10
3
Masonry wall Calculation
12
Wall footing Foundation calculation
15
Tie down Trusses Calculations
18
Tie down Truss Simpson Connections
19
0.
0 63860 •��
O TAT .
E OF `
�00
ON1
Marcus Unterweger
Florida P.E.#: 063860
10/20/2016 13:28
MUEngineers, Inc.
3440 NE 12th Avenue
Oakland Park, FL 33334
954-324-4730
CA #: 29348
JOB TITLE ProphetesResidenceMiamiShores
JOB No. MUE16030301
CALCULATED BY
CHECKED BY
Code Search
Code: Florida Building Code 2010 - High Velocity Zone
Occupancy:
Occupancy Group = R Residential
Risk Category & Importance Factors:
Risk Category = II
Wind factor = 1.00
Snow factor = 1.00
Seismic factor = 1.00
Type of Construction:
Fire Rating:
Roof = 0.0 hr
Floor = 0.0 hr
Building Geometry:
_
Roof angle (0)
4.00 / 12 18.4 deg
Building length (L)
65.5 ft
Least width (B)
43.0 ft
Mean Roof Ht (h)
15.0 ft
Parapet ht above grd
0.0 ft
Minimum parapet ht
0.0 ft
Live Loads:
Roof 0 to 200 sf: 20 psf
200 to 600 sf: 20 psf
over 600 sf: 20 psf
Floor:
Typical Floor
Partitions
Corridors above first floor
Lobbies & first floor corridors
Balconies (e)terior)
0 psf
15 psf
80 psf
100 psf
100 psf
SHEET NO.
DATE
DATE
www.struware.com
3
MUEngineers, Inc.
3440 NE 12th Avenue
Oakland Park, FL 33334
954-324-4730
CA #: 29348
Wind Loads: ASCE 7 - 10
Ultimate Wind Speed
175 mph
Nominal Wind Speed
135.6 mph
Risk Category
II
Exposure Category
C
Enclosure Classif.
Enclosed Building
Internal pressure
+/-0.18
Directionality (Kd)
0.85
Kh easel
0.849
Kh case 2
0.849
Type of roof
Gable
Topographic Factor
(Kzt)
Topography
Flat
Hill Height (H)
0.0 ft
Half Hill Length (Lh)
0.0 ft
Actual H/Lh =
0.00
Use H/Lh =
0.00
Modified Lh =
0.0 ft
From top of crest: x =
0.0 ft
Bldg up/down wind?
downwind
H/Lh= 0.00
K, = 0.000
x/Lh = 0.00
K2 = 0.000
z/Lh = 0.00
K3 = 1.000
At Mean Roof Ht:
Kzt = (1+KjK2K3)^2 = 1.00
Gust Effect Factor
h= 15.0ft
B = 43.0 ft
/z(0.6h)= 15.0ft
Riaid Structure
e =
0.20
l =
500 ft
Zmin =
15 ft
c =
0.20
9a, 9V =
3.4
Lz =
427.1 ft
Q =
0.92
Iz =
0.23
G=
0.88 use G=0.85
JOB TITLE ProphetesResidenceMiamiShores
JOB NO. MUE16030301 SHEET NO.
CALCULATED BY DATE
CHECKED BY DATE
H< 15f ;exp C
.•. Kzt=1.0
F
V(Z)
} Speed-t p
f x(upwind) X(dBWdF MrKl)
H12 H
V(z)
Z
V(Z) x(upwind) I]
Speed-up
x(downwind) -
HI2 H
2D RIDGE or 3D AXISYMMETRICAL HILL
Flexible structure if natural frequency < 1 Hz (T > 1 second).
However, if building h/B < 4 then probably rigid structure (rule of thumb).
h/B = 0.35 Rigid structure
G = 0.85 Using rigid structure default
Flexible or Dvnamically Sensitive Structure
Natural Frequency (qj) =
0.0 Hz
Damping ratio ((3) =
0
/b =
0.65
/a =
0.15
Vz =
147.8
Nj =
0.00
Rn =
0.000
Rh =
28.282 rf = 0.000
RB =
28.282 = 0.000
RL =
28.282 = 0.000
9R =
0.000
R =
0.000
G =
0.000
h= 15.0ft
4
MUEngineers, Inc.
3440 NE 12th Avenue
Oakland Park, FL 33334
954-324-4730
CA #: 29348
JOB TITLE ProphetesResidenceMiamiShores
JOB No. MUE16030301 SHEETNO.
CALCULATED BY DATE
CHECKED BY DATE
Enclosure Classification
Test for Enclosed Building: A building that does not qualify as open or partially enclosed.
Test for Open Building: All walls are at least 80% open.
Ao Z 0.8Ag
Test for Partially Enclosed Building:
Input Test
Ao 0.0 sf Ao z 1.1 Aoi YES
Ag 0.0 sf Ao > 4' or 0.01Ag NO
Aoi 0.0 sf Aoi / Agi s 0.20 NO Building is NOT
Agi 0.0 sf Partially Enclosed
Conditions to qualify as Partially Enclosed Building. Must satisfy all of the following:
Ao z 1.1Aoi
Ao > smaller of 4' or 0.01 Ag
Aoi / Agi s 0.20
Where:
Ao = the total area of openings in a wall that receives positive external pressure.
Ag = the gross area of that wall in which Ao is identified.
Aoi = the sum of the areas of openings in the building envelope (walls and roof) not including Ao.
Agi = the sum of the gross surface areas of the building envelope (walls and roof) not including Ag.
Reduction Factor for large volume partially enclosed buildings (Ri) :
If the partially enclosed building contains a single room that is unpartitioned , the internal
pressure coefficient may be multiplied by the reduction factor Ri.
Total area of all wall & roof openings (Aog): 0 sf
Unpartitioned internal volume (Vi) : 0 cf
Ri = 1.00
Altitude adjustment to constant 0.00256 (caution - see code) :
Altitude = 0 feet
Constant = 0.00256
Average Air Density = 0.0765 Ibm/ft3
5
MUEngineers, Inc.
3440 NE 12th Avenue
Oakland Park, FL 33334
954-324-4730
CA #: 29348
.JOB TITLE ProphetesResidenceMiamiShores
,JOB NO. MUE16030301
CALCULATED BY
CHECKED BY
Wind Loads - MWFRS h560' (Low-rise Buildinas) Enclosed/partially enclosed only
SHEET NO.
DATE
DATE
Kz = Kh (case 1) = 0.85 Edge Strip (a) = 4.3 ft
Base pressure (qh) = 56.6 psf End Zone (2a) = 8.6 ft
GCpi = +/-0.18 Zone 2 length = 21.5 ft
Wind Pressure Coefficients
CASE A
CASE B
0 = 18.4 deg
Surface
GCpf
w/-GCpi
w/+GCpi
GCpi
w/-GCpi
w/+GCpi
1
0.52
0.70
0.34
-0.45
-0.27
-0.63
2
-0.69
-0.51
-0.87
-0.69
-0.51
-0.87
3
-0.47
-0.29
-0.65
-0.37
-0.19
-0.55
4
-0.42
-0.24
-0.60
-0.45
-0.27
-0.63
5
0.40
0.58
0.22
6
1
-0.29
-0.11
-0.47
1 E
0.78
0.96
0.60
-0.48
-0.30
-0.66
2E
-1.07
-0.89
-1.25
-1.07
-0.89
-1.25
3E
-0.67
-0.49
-0.85
-0.53
-0.35
-0.71
4E
-0.62
-0.44
-0.80
-0.48
-0.30
-0.66
5E
0.61
0.79
0.43
6E
-0.43
-0.25
-0.61
Ultimate Wind Surface Pressures (psf)
1
39.4 19.0
-15.3 -35.6
2
-28.9 -49.2
-28.9 -49.2
3
-16.3 -36.7
-10.7 -31.1
4
-13.3 -33.7
-15.3 -35.6
5
32.8 12.4
6
1
-6.2 -26.6
1 E
54.3 34.0
-17.0 -37.3
2E
-50.3 -70.7
-50.3 -70.7
3E
-27.9 -48.3
-19.8 -40.2
4E
-24.8 -45.1
-17.0 -37.3
5E
44.7 24.3
6E
-14.1 -34.5
Parapet
Windward parapet = 0.0 psf (GCpn = +1.5)
Leeward parapet = 0.0 psf (GCpn = -1.0)
Horizontal MWFRS Simple Diaohraam Pressures (os
Transverse direction (normal to L)
Interior Zone: Wall 52.7 psf
Roof -12.5 psf **
End Zone: Wall 79.1 psf
Roof -22.4 psf **
Longitudinal direction (parallel to L)
Interior Zone: Wall 39.0 psf
End Zone: Wall 58.8 psf
** NOTE: Total horiz force shall not be less than that determined
by neglecting roof forces (except for MWFRS moment frames).
The code requires the MWFRS be designed for a min ultimate
force of 16 psf multiplied by the wall area plus an 8 psf force
applied to the vertical projection of the roof.
Windward roof
overhangs = 39.6 psf (upward) add to
windward roof pressure
WINDWARD
OVERHANG {-f, WINDWAR.DRAOF
LEEWARD ROOF
I t t 1 1 J t J 1!
VERTICAL
o
3 x
TRANSVERSE ELEVATION
WINDWARD ROOF
LEEWARD ROOF
VERTICAL
LONGITUDINAL ELEVATI014
MUEngineers, Inc.
JOB TITLE ProphetesResidenceMiamiShores
3440 NE 12th Avenue
Oakland Park, FL 33334
JOB NO. MUE16030301 SHEET NO.
954-324-4730
CALCULATED BY DATE
CA M 29348
CHECKED BY DATE
Location of MWFRS Wind Pressure Zones
4 .�
,,p,,.
3E
,„ram �r
yr,
ZONE 2_ lessor of
0.5 B or 2.5 h
If 2 is negative
CASE A �MNTD DIRECTTO CASE B
RANGE �t Lti DIRE C`no
RA?
NOTE: Torsional loads are 25% of zones 1 - 6. See code for loading diagram.
ASCE 7 -99 and ASCE 7-10 M later)
4
E
6
----- ZONE 2: lessor of
0.5 B or 2.5 h
' If 2 is negati,
%
W'MD EC CN
Transverse Directiou Longitudinal Direction
NOTE: Torsional loads are 25% of zones 1 - 4. See code for loading diagram.
7
MUEngineers, Inc. JOB TITLE ProphetesResidenceMiamiShores
3440 NE 12th Avenue
Oakland Park, FL 33334 JOB NO. MUE16030301 SHEET NO.
954-324-4730 CALCULATED BY DATE
CA #: 29348 CHECKED BY DATE
Ultimate Wind Pressures
Wind Loads - Components & Cladding : h <= 60'
Kh (case 1) = 0.85 h = 15.0 ft
Base pressure (qh) = a = 4.3 ft
Minimum parapet hi= 0.0 ft GCpi = +/-0.18
Roof Angle (0) = 18.4 deg
Type of roof = Gable
Roof
Aree
Negative Zone 1
Negative Zone
Negative Zone
Positive All ZoneE
Overhang Zone ,
Overhang Zone
Parapet
GCp +/- GCpi
Surface Pressure (psf)
User input
10 sf
50 sf
100 sf
10 sf
50 sf
100 sf
75 sf
500 sf
-1.08
-1.01
-0.98
-61.1
-57.1
-55.4
-56.1
-55.4
-1.88
-1.53
-1.38
-106.4
-86.6
-78.1
-81.6
-78.1
-2.78
-2.36
-2.18
-157.3
-133.5
-123.3
-127.6
-123.3
0.68
0.54
0.48
38.5
30.6
27.2
28.6
27.2
-2.20
-2.20
-2.20
-124.5
-124.5
-124.5
-124.5
-124.5
-3.70
-2.86
-2.50
-209.3
-161.9
-141.4
-149.9
-141.4
uvemang pressures in me taDie apove assume an miemai pressure coemcient tvcpi/ or u.0
Overhang soffit pressure equals adjacent wall pressure reduced by internal pressure of 10.2 psf
qp = 0.0 psf
CASE A = pressure towards building (pos)
CASE B = pressure away from bldg (neg)
Walls
Area
Negative Zone 4
Negative Zone E
Positive Zone 4 & E
Solid Parapet Pressure
Surface Pressure s
User input
10 sf
100 sf
500 sf
40 sf
SASE A: Interior zone:
Corner zone:
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
SASE B : Interior zone:
Corner zone:
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
GCp +/- GCpi
Surface Pressure (psf)
User input
10 sf
100 sf
500 sf
10 sf
100 sf
500 sf
40 sf
200 sf
-1.28
-1.10
-0.98
-72.4
-62.4
-55.4
-66.4
-59.4
-1.58
-1.23
-0.98
-89.4
-69.4
-55.4
-77.4
-63.4
1.18
1.00
0.88
66.8
56.8
49.8
60.7
53.8
8
MUEngineers, Inc.
JOB TITLE ProphetesResidenceMiamiShores
3440 NE 12th Avenue
Oakland Park, FL 33334
JOB No. MUE16030301 SHEET NO.
954-324-4730
CALCULATED BY DATE
CA #: 29348
CHECKED BY DATE
Roofs w/ e 5 10'
and all walls
h>60'
T L'J i I
1 I
2 1 I
I <D 2
Monoslope roofs
10°<0530'
h 5 60' & aft design h<90'
it
Location of C&C Wind Pressure Zones
Walls h 5 60'
& alt design h<90'
Multispan Gable &
Gable 7° < e 5 45°
Stepped roofs e 5 3°
h 5 60' & aft design h<90'
9
Ultimate Wind Pressures
i I -r 3 j----J_r.
I I _
t I -I
21 0 ( I2I 1 I
I I I
I I 1 I
3 2 2 3
Gable, Sawtooth and
Multispan Gable e 5 7 degrees &
Monoslope 5 3 degrees
h <_ 60' & aft design h<90'
Hip 7° < e 5 27'
Monoslope roofs
3°<6510'
h 5 60' & aft design h<90'
Sawtooth 10' < 9 5 45'
h 5 60' & aft design h<90'
MUEngineers, Inc.
3440 NE 12th Avenue
Oakland Park, FL 33334
954-324-4730
CA M 29348
JOB TITLE ProphetesResidenceMiamiShores
JOB NO. MUE16030301
CALCULATED BY
CHECKED BY
Roof Design Loads
SHEET NO.
DATE
DATE
Items
Description Multiple
p
psf min
Roofing
Spanish Tile
19.0
16.0
Roofing
Bituminous membrane, smooth surface
1.5
1.5
Decking
3/4" plywood/OSB
2.7
2.3
Framing
Wood Trusses @ 24" x 2.0
6.0
5.0
Insulation
R-30 Fiberglass insul.
0.9
0.9
Ceiling
5/8" gypsum
2.8
2.5
Mech & Elec
Mech. & Elec.
2.0
0.0
Misc.
Misc.
0.5
0.0
Actual Dead Load
• 35.4
• 28.2
Use this DL instead
25.0
20.0
Live Load
20.0
0.0
Snow Load
0.0
0.0
Ultimate Wind (zone 2 - 100sf)
27.2
-78.1
A D Loadinq D + Lr
55.4
-
D + 0.75(0.6*W + Lr)
62.6
-
0.6*D + 0.6*W
-
-29.9
LRFD Loadinq 1.2D + 1.6 Lr + 0.5W
88.1
-
1.2D + 1.OW + 0.51-r
79.6
-
0.9D + 1.0W
-
_
-52.7
Roof Live Load Reduction
0 to 200 sf: 20.0 psf
200 to 600 sf: 20.0 psf
over 600 sf: 20.0 psf
User Input:
300 sf
18.0 psf
400 sf
16.0 psf
500 sf
14.0 psf
450 sf
15.0 psf
Roof angle 4.00 / 12 18.4 deg
10
MUEngineers, Inc.
3440 NE 12th Avenue
Oakland Park, FL 33334
954-324-4730
CA #: 29348
JoB TITLE ProphetesResidenceMiamiShores
JOB NO. MUE16U3U3U7
CALCULATED BY
CHECKED BY
Floor Design Loads
SHEET NO.
DATE
DATE
Items
IDescription Multiple
1psf (max)
psf (min)
Flooring
3/4" Ceramic tile on 1" mortar
23.0
20.0
Flooring
Carpet & pad x 1.0
1.0
1.0
None
0.0
0.0
None
0.0
0.0
None x 10.0
0.0
0.0
None
0.0
0.0
None
0.0
0.0
None
0.0
0.0
None
0.0
0.0
Actual Dead Load
• 24.0
• 21.0
Use this DL instead
25.0
20.0
15.0
0.0
Partitions
Live Load
0.0
-15.0-
0.0 _
Total Live Load
0.0
39.0
21.0
Total Load
FLOOR LIVE LOAD REDUCTION (not includina partitions)
NOTE: Not allowed for assembly occupancy or LL>100psf or passenger car
garages, except may reduce columns 20% if 2 or more floors & non -assembly
L=Lo(0.25+15NKLLAT)
Unreduced design live load: Lo = 0 psf
Floor member KLL = 2
Tributary Area AT = 300 sf
Reduced live load: L = 0.0 psf
Columns (2 or more floors) KLL = 4
Tributary Area AT = 500 sf
Reduced live load: L = 0.0 psf
IBC alternate procedure
Smallest of:
R= .08%(SF - 150)
R= 23.1(1+D/L) = #DIV/0!
R= 40% beams; 60% columns
R = #DIV/0!
Reduced live load: L = #DIV/0!
R = #DIV/0!
Reduced live load: L = #DIV/0!
it
Masonry Slender Wall
1./1•
Description : Masonry Wall
Code References
Calculations per ACI 530-11, IBC 2012, CBC 2013, ASCE 7-10
Load Combinations Used: ASCE 7-10
General Information
1esidencs1MiamiShoresWxftnue16030301.ec6
INC 198332015, Build:6.15.10.6, Ver:6.15.10.6
Calculations per ACI 530-11, IBC 2012, CBC 2013, ASCE 7-10
Construction Type: Grouted Hollow Concrete Masonry
Fm = 1.50 ksi
Nom. Wall Thickness
8 in Temp Diff across thickness = deg F
Fy - Yield = 60.0 ksi
Actual Thickness
7.625 in Min Allow Out -of -plane Dell Ratio = 0
Fr - Rupture = 61.0 psi
Rebar'd' distance
3.750 in Minimum Vertical Steel % = 0.0020
Em = fm * = 900.0
Lower Level Rebar ...
Max %of p bal. = 0.006794
Bar Size ##
5
Grout Density = 140 pcf
Bar Spacing
32.0 in
Block Weight Normal Weight
Wall Weight = 58.0 psf
Wall is grouted at rebar cells only
One -Story Wall Dimensions
A Clear Height = 13.50 ft B
B Parapet height = ft
Wall Support Condition Top Pinned, Bottom F —�
Vertical Loads
Vertical Uniform Loads ... (Appl'ed per foot of Strip Width)
Ledger Load Eccentricity in
Concentric Load
Lateral Loads
Wind Loads:
Full area WIND bad 75.0 psi
Fp 1.0 = 25.0 psf
,'bor;.ttachmen;
DL : Dead Lr : Rod Live Lf : Floor Live S : Snow W : Wind
0.480 0.40 Vt
k/ft
Seismic Loads:
Wall Weight Seismic Load Input Method
Seismic Wall Lateral Load
Direct entry of Lateral Wall Weight
25.0 psf
12
Masonry Slender Wall
File=P'AdiveWUE16030301-SB-PrcphetsResidaioWiamiShaes%KKftnue16D30301.ec6
•)
ENERCALC,
INC. 19632015, BLW6.15.10.6, Ver6.15.10.6
Description: Masonry Wall
DESIGN SUMMARY
Results reported for "Strip Width" of 12.0 in
Goveming
Load Combination ...
Actual Values ...
Allowable Values ...
PASS Moment Capacity Check
Maximum Bending Stress Ratio =
0.8698
+1.20D+0.50Lr+0.50L+W+1.60H
Max Mu
-1.659 k-ft Phi * Mn 1.908 k-ft
PASS Service Deflection Check
Actual Dell. Ratio U
351
Allowable Defl. Ratio 150
W Only
Max. Deflection
0.4618 in
PASS Axial Load Check
Max Pu / Ag
36.124 psi
Max. Allow. Defl. 1.080 in
+1.20D+0.50Lr+0.50L+W+1.60H
Location
0.2250 ft
0.2 *fm 300.0 psi
PASS Reinforcing Limit Check
Controlling As/bd
0.00250
AsN006794 rho bal 0.006794
PASS Minimum Moment Check
Mcracking
0.5935 k-ft Minimum Phi Mn 2.120 k-ft
+1.40D+1.60H
Maximum Reactions ...
for Load Combination....
Top Horizontal
W Only
0.3828 k
Base Horizontal
W Only
0.6297 k
Vertical Reaction
+D+Lr+H
1.663 k
Design Maximum Combinations - Moments
Results reported for "Strip Width" = 12 in.
Axial Load
Moment Values
0.6 *
Load Combination
Pu 0.21m*b*t
Mcr Mu Phi
Phi Mn
As As Ratio rho bal
k
k
k-ft k-ft
k-ft
in^2
0.000
0.000
0.00 0.00 0.00
0.00
0.000 0.0000 0.0000
0.000
0.000
0.00 0.00 0.00
0.00
0.000 0.0000 0.0000
0.000
0.000
0.00 0.00 0.00
0.00
0.000 0.0000 0.0000
0.000
0.000
0.00 0.00 0.00
0.00
0.000 0.0000 0.0000
+1.20D+1.60Lr+0.50W+1.60H at 0.00 to 0.45
0.000
17.640
0.46 1.28 0.90
1.91
0.116 0.0025 0.0068
0.000
0.000
0.00 0.00 0.00
0.00
0.000 0.0000 0.0000
+1.20D+1.60S+0.50W+1.60H at 0.00 to 0.45
0.000
17.640
0.46 1.29 0.90
1.91
0.116 0.0025 0.0068
+1.20D-+0.50Lr+0.50L+W+1.60H at 0.00 to 0.
0.000
17.640
0.46 1.66 0.90
1.91
0.116 0.0025 0.0068
+1.20D+0.50L+0.50S+W+1.60H at 0.00 to 0.4
0.000
17.640
0.46 1.66 0.90
1.91
0.116 0.0025 0.0068
+1.20D+0.50L+0.20S+E+1.60H at 0.00 to 0.4
0.000
17.640
0.46 0.57 0.90
1.91
0.116 0.0025 0.0068
+0.90D4W40.90H at 0.00 to 0.45
0.000
17.640
0.46 1.66 0.90
1.91
0.116 0.0025 0.0068
+0.90D+E+0.90H at 0.00 to 0.45
0.000
17.640
0.46 0.57 0.90
1.91
0.116 0.0025 0.0068
Design Maximum Combinations - Deflections
Results reported for "Strip Width" = 12 in.
Axial Load
Moment
Values
Stiffness
Deflections
Load Combination
Pu
Mcr
Mactual I gross
I cracked
I effective Deflection Defl. Ratio
k
k ft
k-ft in14
`.n^4
,n^4 in
0.000
0.00
0.00 0.00
0.00
0.000 0.000 0.0
0.000
0.00
0.00 0.00
0.00
0.000 0.000 0.0
0.000
0.00
0.00 0.00
0.00
0.000 0.000 0.0
0.000
0.00
0.00 0.00
0.00
0.000 0.000 0.0
0.000
0.00
0.00 0.00
0.00
0.000 0.000 0.0
0.000
0.00
0.00 0.00
0.00
0.000 0.000 0.0
+0+0.60W+H at 8.10 to 8.55
0.793
0.46
0.36 342.40
26.73
342.400 0.101 1,605.4
+D+0.70E+H at 7.65 to 8.10
0.819
0.46
0.22 342.40
26.80
342.400 0.012 13,758.2
+D+0.750Lr+0.750L+0.450W+H at 7.65 to 8.1
1.119
0.46
0.28 342.40
27.60
342.400 0.049 3,283.5
+D+0.750L+0.750S+0.450W+H at 7.65 to 8.10
0.819
0.46
0.28 342.40
26.80
342.400 0.050 3,256.0
+D.+0.750L.+0.750S+0.5250E+H at 7.65 to 8.1
0.819
0.46
0.17 342.40
26.80
342.400 0.009 18,344.2
+0.60D+0.60W+0.60H at 8.10 to 8.55
0.476
0.46
0.36 342.40
25.87
342.400 0.102 1,590.0
+0.60D40.70E+0.60H at 7.65 to 8.10
0.492
0.46
0.22 342.40
25.91
342.400 0.012 13,769.9
0.000
0.00
0.00 0.00
0.00
0.000 0.000 0.0
0.000
0.00
0.00 0.00
0.00
0.000 0.000 0.0
0.000
0.00
0.00 0.00
0.00
0.000 0.000 0.0
13
•
masonry Slender Wall
File=P:WdivelMUE160303D1-SB-PropWsResiknceMiamiShoreslergMue16030301.ec6
ENERCALC, INC. 1983-2015, Build:6.15.10.6, Ver6.15.10.6
t.11•
• "
Description: Masonry Wall
Design Maximum Combinations -
Deflections
Results reported for "Strip Width" =12 in.
Axial Load
Moment Values
Stiffness
Deflections
Load Combination
Pu
Mcr
Mactual
I gross
I cracked I effective
Deflection Defl. Ratio
k
k-ft
K it
in^4
in14 in^4
,.i
0.000
0.00
0.00
0.00
0.00 0.000
0.000 0.0
W Only at 7.65 to 8.10
0.000
0.46
0.96
342.40
24.55 25.241
0.462 350.8
E Only at 7.65 to 8.10
0.000
0.46
0.32
342.40
24.55 342.400
0.017 9,651.2
0.000
0.00
0.00
0.00
0.00 0.000
0.000 0.0
Reactions - Vertical & Horizontal
Results reported for "Strip Width" = 12 in.
Load Combination
Base Horizontal
Top Horizontal
Vertical @ Wall Base
_
+D+H
0.0
k
0.00 k
1.263 k
+D+L+H
0.0
k
0.00 k
1.263 k
+D+Lr+H
0.0
k
0.00 k
1.663 k
+D+S+H
0.0
k
0.00 k
1.263 k
+D+0.750Lr+0.750L+H
0.0
k
0.00 k
1.563 k
+D+0.750L+0.750S+H
0.0
k
0.00 k
1.263 k
+D+0.60W+H
0.4
k
0.19 k
1.263 k
+D+0.70E+H
0.1
k
0.09 k
1.263 k
+D-#0.750Lr+0.750L+0.450W+H
0.3
k
0.14 k
1.563 k
+D+0.750L+0.750S+0.450W+H
0.3
k
0.14 k
1.263 k
+D+0.750L+0.750S+0.5250E+H
0.1
k
0.07 k
1.263 k
+0.60D+0.60W+0.60H
0.4
k
0.19 k
0.758 k
+0.60D+0.70E+0.60H
0.1
k
0.09 k
0.758 k
D Only
0.0
k
0.00 k
1.263 k
Lr Only
0.0
k
0.00 k
0.400 k
L Only
0.0
k
0.00 k
0.000 k
S Only
0.0
k
0.00 k
0.000 k
W Only
0.6
k
0.38 k
0.000 k
E Only
0.2
k
0.13 k
0.000 k
H Only
0.0
k
0.00 k
0.000 k
14
Wall Footing File=P,Adiva\MUE16030301-SB-ProphetsResiderxeMiamiShoroslerx3Ynue16030301.ec6 till
9 ENERCALC, INC. 19n2015, 8tnld:6.15.10.6, Ver:6.15.10.6
Description: Wall Footing
Code References
Calculations per ACI 318-11, IBC 2012, CBC 2013, ASCE 7-10
Load Combinations Used: ASCE 7-10
General Information
Material Properties
Soil Design Values
fc : Concrete 28 day strength =
3.0 ksi
Allowable Soil Bearing
Rebar Yield =
60.0 ksi
Increase Bearing By Footing Weight
c : Concrete Elastic Modulus =
3,122.0 ksi
Soil Passive Resistance (for Sliding)
Concrete Density =
145.0 pcf
Soil/Concrete Friction Coeff.
rp Values Flexure =
Shear =
0.90
0.750
Increases based on footing Depth
Analysis Settings
Reference Depth below Surface
Allow. Pressure Increase per foot of depth
Min Steel % Bending Reinf. =
when base footing is below
Min Allow % Temp Reinf. =
0.00180
Min. Overturning Safety Factor =
1.0 :1
Increases based on footing Width
Min. Sliding Safety Factor =
1.0 : 1
Allow. Pressure Increase per foot of width
AutoCak: Footin Wei ht as DL
Yes
when footing is wider than
9 9
Dimensions
Footing WidIJ = 2.0 ft Footing Thicimes =
Wall Thickness = 6.0 in Rebar Centerline to Edge of Concrete.
Wall center offset at Bottom of footing =
from center of footing = 0 in
1.50 ksf
250.0 pcf
0.30
ft
ksf
ft
ksf
= ft
Reinforcing
12.0 in Bars along X-X Axis
Bar spacing = 12.00
3.0 in Reinforcing Bar Size = # 5
t 5 bars a 12 In o
Applied Loads
D Lr L
S
W E H
P : Column Load
=
1.50 0.40
k
OB : Overburden
=
ksf
V-x
=
0.30
k
M-iz
=
kft
Vx applied =
in above top of footing
DESIGN SUMMARY
• •
Min. Ratio
Item
Capacity
Governing Load Combination
PASS 0.8299
Soil Bearing
1.245 ksf
1.50 ksf
+D+0.750Lr+0.750L+6.
PASS 5.967
Overturning Z-Z
1.074 k ft
+0.60D+0.60W+0.60H
PASS 1.790
Sliding - X-X
0.180 k
0.3222 k
+0.60D+0.60W+0.60H
PASS n/a
Uplift
0.0 k
0.0 k
No Uplift
PASS 0.03623
Z Flexure (+X)
0.4395 k ft
12.131 k-ft
+1.20D+1.60Lr+0.50W+
PASS 0.01868
Z Flexure (-X)
0.2265 k-ft
12.131 k-ft
+0.90D+E+0.90H
PASS n/a
1-way Shear (+X)
0.0 psi
82.158 psi
n/a
PASS 0.0
1-way Shear (-X)
0.0 psi
0.0 psi
n/a
Wall Footin
File=P:lNdiveW.UE16030301-SB-ProphetsResidenceMianiShoreslengVnuel6030301ecs
9
ENERCALC, INC. 1983-2016, Bulld.6.15.10.6, Ver.6.16.10.6
• 1./1•
.. .....
..
Description: Wall Footing
Detailed Results
Soil Bearing
Rotation Axis &
Actual Soil Bearing Stress
Actual / Allowable
Load Combination...
Gross Allowable
Xecc Zecc
+Z +Z -X
-X
Ratio
+D+H
1.50 ksf
0.0 in
0.8950 ksf
0.8950 ksf
0.597
+D+L+H
1.50 ksf
0.0 in
0.8950 ksf
0.8950 ksf
0.597
+D+Lr+H
1.50 ksf
0.0 in
1.095 ksf
1.095 ksf
0.730
+D+S+H
1.50 ksf
0.0 in
0.8950 ksf
0.8950 ksf
0.597
+D+0.750Lr+0.750L+H
1.50 ksf
0.0 in
1.045 ksf
1.045 ksf
0.697
+D+0.750L+0.750S+H
1.50 ksf
0.0 in
0.8950 ksf
0.8950 ksf
0.597
+D+0.60W+H
1.50 ksf
1,207 in
0.6286 ksf
1.161 ksf
0.774
+D+0.70E+H
1.50 ksf
0.0 in
0.8950 ksf
0.8950 ksf
0.597
+D+0.750Lr+0.750L+0.450W+H
1.50 ksf
0.7751 in
0.8452 ksf
1.245 ksf
0.830
+D+0.750L+0.750S+0.450W+H
1.50 ksf
0.9050 in
0.6952 ksf
1.095 ksf
0.730
+D+0.750L40.75OS+0.5250E+H
1.50 ksf
0.0 in
0.8950 ksf
0.8950 ksf
0.597
+0.60D+0.60W+0.60H
1.50 ksf
2.011 in
0.2706 ksf
0.8034 ksf
0.536
+0.60D+0.70E+0.60H
1.50 ksf
0.0 in
0.5370 ksf
0.5370 ksf
0.358
Overturning Stability
Units: k-ft
Rotation Axis &
Load Combination...
Overturning Moment
Resisting Moment
Stability Ratio
Status
+D+H
None
0.0 k-ft
Infinity
OK
+D+L+H
None
0.0 k-ft
Infinity
OK
+D+Lr+H
None
0.0 k-ft
Infinity
OK
+D+S+H
None
0.0 k-ft
Infinity
OK
+D+0.750Lr+0.750L+H
None
0.0 k-ft
Infinity
OK
+D+0.750L+0.750S+H
None
0.0 k-ft
Infinity
OK
+D+0.60W+H
0.180 k-ft
1,790 k-ft
9.944
OK
+D+0.70E+H
None
0.0 k-ft
Infinity
OK
+D+0.750Lr+0.750L+0.450W+H
0.1350 k-ft
2.090 k-ft
15.481
OK
+D+0.750L+0.750S+0.450W+H
0.1350 k-ft
1.790 k-ft
13.259
OK
+D+0.750L+0.750S+0.5250E+H
None
0.0 k-ft
Infinity
OK
+0.60D+0.60W+0.60H
0.180 k-ft
1.074 k-ft
5.967
OK
+0.60D+0.70E+0.60H
None
0.0 k-ft
Infinity
OK
Sliding Stability
Force Application Axis
Load Combination...
Sliding Force
Resisting Force
Sliding SafetyRatio
Status
+D+H
0.0 k
0.5370 k
No Slidinq
OK
+D+L+H
0.0 k
0.5370 k
No Slidinq
OK
+D+Lr+H
0.0 k
0.6570 k
No Slidinq
OK
+D+S+H
0.0 k
0.5370 k
No Slidinq
OK
+D+0.750Lr+0.750L+H
0.0 k
0.6270 k
No Slidinq
OK
+D+0.750L+0.750S+H
0.0 k
0.5370 k
No Slidinq
OK
+D+0.60W+H
0.180 k
0.5370 k
2.983
OK
+D+0.70E+H
0.0 k
0.5370 k
No Slidinq
OK _
+D+0.750Lr+0.750L+0.450W+H
0.1350 k
0.6270 k
4.644
OK
+D+0.750L+0.750S+0.450W+H
0.1350 k
0.5370 k
3.978
OK
+D+0.750L+0.750S+0.5250E+H
0.0 k
0.5370 k
No Slidinq
OK
+0.60D+0.60W+0.60H
0.180 k
0.3222 k
1.790
OK -
+0.60D+0.70E+0.60H
0.0 k
0.3222 k
No Slidinq
OK
Footing Flexure
Flexure Axis &Load Combination
Mu Which Tension g Bot. As Req'd
Gvrn. As
Actual As Phi'Mn
k-ft Side ? or Top ? in12
in"2
in^2
k-ft Status
, +1.40D+1.60H
0.3524
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
, +1.40D+1.60H
0.3524
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50Lr+1.60L+1.60H
0.3302
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50Lr+1.60L+1.60H
0.3302
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60L+0.50S+1.60H
0.3021
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60L+0.50S+1.60H
0.3021
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60Lr+0.50L+1.60H
0.3921
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60Lr+0.50L+1.60H
0.3921
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60Lr+0.50W+1.60H
0.3446
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60Lr+0.50W+1.60H
0.4395
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50L+1.60S+1.60H
0.3021
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
NO
Footing ENERC&C, INC. 1 1. 1.
Lic'F# KW 06009175 �. :=ry x. "zk= :s: p na�r, Licensee: MUEngineers Inc
Description: Wall Footing
Footing Flexure
Flexure Axis & Load Combination
Mu Which
Tension @ Bot.
As Req'd
Gvrn. As
Actual As
Phi`Mn
k-ft Side
?
or Top ?
in"2
in"2
in"2
k-ft
Status
+1.20D+0.50L+1.60S+1.60H
0.3021
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1 . 20D+1.60S+0.50W+1.60H
0.2546
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60S+0.50W+1.60H
0.3495
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50Lr+0.50L+W+1.60H
0.2353
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50Lr+0.50L+W+1.60H
0.4251
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50L+0.50S+W+1.60H
0.2072
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50L+0.50S+W+1.60H
0.397
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50L+0.20S+E+1.60H
0.3021
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50L+0.20S+E+1.60H
0.3021
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
, +0.90D+W+0.90H
0.1316
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
, +0.90D+W+0.90H
0.3214
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
, +0.90D+E+0.90H
0.2265
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
• +0.90D+E•+0.90H
0.2265
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
One Way Shear
Units: k
Load Combination...
Vu P -X
Vu @
+X
Vu:Max
Phi Vn
Vu I Phi'Vn
Status
+1.40D+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+0.50Lr+1.60L+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+1.60L+0.50S+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+1.60Lr+0.50L+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+1.60Lr+0.50W+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+0.50L+1.60S+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+1.60S+0.50W+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+0.50Lr+0.50L+W+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+0.50L+0.50S+W+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+0.50L+0.20S+E+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+0.90D+W+0.90H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+0.90D+E+0.90H
0 psi
0 psi
0 psi
82.158 psi
0
OK
3:05 PM
10l7I2016
ngineers, Inc.
www.MUEna�neers.com Tie Down Trusses Calculations
GT
OVER HANG LENGTH
ZOON2
ZOON2
LENGTH(FEET)
2.5
15
WIDTH(FEET)
4.125
4.125
AREA
10.3125
61.875
WIND PRESSURE
-128
-128
UPLIFT
-1318
-7908
TOTAL UPLIFT
-9226
DEALLOAD
722
TOTAL TIE DOWN CONNECTION "A"
UPLIFT FORCE(0.6DI+0.6WIND)
-2334.54375
HT
OVER HANG LENGTH
ZOON3
ZOON3
ZOON2
OVER HANG
LENGTH ZOON2
LENGTH(FEET)
8.6
4.3
4
2
WIDTH(FEET)
1.25
4.3
2
1.3
AREA
10.75
18.49
8
2.6
WIND PRESSURE
-215
-151
-100
-19
UPLIFT
-2310
-2792
-803
-50
TOTAL UPLIFT/2
-2978
DEALLOAD
436
TOTAL TIE DOWN CONNECTION "B"
UPLIFT FORCE(DI+0.6WIND)
-1350.2355
JT
OVER HANG LENGTH
ZOON2
ZOON2
LENGTH(FEET)
1.25
5
WIDTH(FEET)
2
2
AREA
2.5
10
WIND PRESSURE
-128
-109
UPLIFT
-320
-1092
TOTAL UPLIFT IN CONNECTION
-866
DEALLOAD
188
TOTAL TIE DOWN CONNECTION "C"
UPLIFT FORCE(DI+0.6WIND)
-332
T
OVER HANG LENGTH
ZOON2
ZOON2
LENGTH(FEET)
4.75
5
WIDTH(FEET)
2
2
AREA
9.5
10
WIND PRESSURE
-128
-109
UPLIFT
-1214
-1092
TOTAL UPLIFT IN CONNECTION
-1760
DEALLOAD
57
60
TOTAL TIE DOWN CONNECTION "D"
UPLIFT FORCE(DI+0.6WIND)
-999
P.WctiveWUE16030301SB-ProphelsResidnnmMiaMShoreslengWUE16030301-TIEDOWN TRUSS CALCULATION 1 of
18
Mark on Plan
Anchor / Connector Type
FASTENERS
TO TRUSS
A
Simpson MGT
(22) 10 d Nails
B
Simpson HETA16
(9) 10d x 1 1/2"Nail
C
Simpson META 16
(7) 10d x 1 1/2"Nail
D
Simpson META6
1(7) 10 d x 1 1/2" Nails
19
BUILDING PERMIT CATEGORIES
CATEGORY DESCRIPTION PERMIT TYPE
BUILDING
01
GENERAL BUILDING -COMMERCIAL
MBLD
02
SUB -GENERAL BUILDING -RESIDENTIAL
MBLD
08
CANVAS AWNING
MBLD
10
COMMUNICATION TOWER
MBLD
15
DEMOLITION
MBLD
29
METAL AWNING & STORM SHUTTER
MBLD
48
SCREEN ENCLOSURES
MBLD
51
MURAL SIGNS (NON -ELECTRICAL)
MBLD
55
SWIMMING POOL
MBLD
56
TENNIS COURTS (SURFACE PAVING)
MBLD
86
TRAILER TIE DOWN
MBLD
88
WALK-IN COOLER
MBLD
91
MARINAS
MBLD
92
LOW SLOPE APPLICATIONS (GRAVEL, SMOOTH
MODIFIED, SINGLE PLY)
MBLD
95
SHINGLES (ASPHALT, FIBERGLASS)
MBLD
96
SHINGLES (METAL ROOFS/WOOD SHINGLES & SHAKE)
MBLD
97
STAGE 2 VAPOR RECOVERY SYSTEM
MBLD
99
SOIL IMPROVEMENT
MBLD
0100
BULK STORAGE PROPANE TANK
MBLD
0101
REMOVABLE STORM PANELS
MBLD
0107
TILE ROOF
MBLD
0110
WATER MAIN
MBLD
0111
SITE PLAN
MBLD
0112
INDOOR EVENT/EXHIBIT
MBLD
ELECTRICAL
04
FIRE ALARM SPECIALTY
MELE
16
SPECIALTY WIRING
MELE
38
GENERATORS
MELE
PLUMBING
0024
INTERCEPTOR/GREASE TRAPS (REPLACEMENT OR
INSTALLATION THAT IS NOT PART OF A BUILDING PERMIT)
MPLU
LPGX
01
LIQUEFIED PETROLEUM GAS
MLPG
02
MISCELLANEOUS
MLPG
04
LIQUEFIED PETROL. GAS/STATE
MLPG
MECHANICAL
09
ABOVE/BELOW GROUND TANKS/PUMPS
& POLLUTANT STORAGE SYSTEM
MMEC
38
COMMERCIAL HOODS
MMEC
43
FIRE CHEMICAL
MMEC
46
SPRAY BOOTHS
MMEC
48
SMOKE CONTROL
MMEC
52
RESIDENTIAL ELEVATOR
MMEC
FIRE
32
FIRE SPRINKLER
FIRE
A -
-fnac)v�-Wj5ii
`NOTE: ALL SHEETS MUST BE REVIEWED
MIAMI-DADE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES
Herbert S. Saffir Permitting and Inspection Center
11805 SW 26th Street (Coral Way) • Miami, Florida 33175-2474 • (786) 315-2000
APPLICATION FOR MUNICIPAL PERMIT APPLICANTS
THAT REQUIRE PLAN REVIEW FROM MIAMI-DADE FIRE RESCUE
AND/OR ENVIRONMENTAL SERVII;0�
,Ilo
PROVIDE MUNICIPAL PROCESS NUMBER HERE
Address IRO NX0 101 � -5315-D
Contractor No.'PSli QWS We kurn
U.Job
o z
W
Folio 11 6101 , 0�3 - h110
z
o0
� �
Last four (4) digits of Qualifier No.000 151SClO l
oW
Qa
t
Contractor NameQ,fC SCC1Y%ii►'ULCQh
3
f >
00
Lot 1 'i'D Block
cc cc
Qualifier Name W ii SY.
0
j
Subdivision Bow ry-)► r PA e1- PBpg
0U.
O z
Address l 700 NE
CityN• r»101)ml State Fl Zip -3 1
Metes and bounds
[ ] New Construction on
[ ] Demolish
Current use of property Q. &S Ct tLj
F
Vacant Land
[ ] Shell Only
Alteration Interior
[ �j Addition Attached
og
[ ] Alteration Exterior
[ ] Addition Detached
Description of Work CLCWi%torl o� ✓raStztt
W W
a>o
[ ] Relocation of Structure
[ ] Re -Roof
►2er1 rw-�w�
Sq. Ft. 158 Units 1 Floors 1
a
[ ] Enclosure
[ ] Foundation Only
[ ]Repair
[ ]Tent
[ ] Repair Due to Fire
Value of Work *4D 000
[ ] MBLD'
C
N
[ ] Chg. Contractor
W
Owner e14grct N-uphRte_
Address 190 I\W 101 &T
a
Category
g ry
[ ] Re -Issue
a
City 1'Y l8ro1 ShprtS State V� Zip 33iSD
[ ] MELE
N
[ ] Re -Stamp
y
¢
[ ] MPLU
w
[ ] Revision
W
Phone3yS 3i$4ci-)?
a
[ ] MLPG
MMEC
w
[ ] Not Applicable for
3
Last four (4) digits of
[ ] FIRE
Fire
O
Owner's Social Security No.
ozw
Name f �t�1 S06f &DCOU �h
Owner
Address 1"?QO � 143 �?
Address
zg
FW
FZ
Oa
w Y
City t4. frm10,1yr, State VL Zip 3318
v z
City State _Zip
as
Phone
¢W
Phone
z
I am requesting a Special Request Plan Review (SRI) to be scheduled as soon as possible at the rate of $209 for the first hour
a g
and $71.50 per each additional hour in addition to the review fees. Minimum charge one -hour.
(� d CO
a. 3
1 st Request: Date:
w Uj
ccw ¢
2"d Request: Date:
M
31d Request: Date:
z
g
1 am requesting Optional Plan Review (OPR) to be scheduled as soon as possible at the rate of $75 for each discipline.
aAdditional
review fees may apply.
O
03
1st Request: Date:
P W
o w
2nd Request: Date:
a cc
w
31d Request: Date:
IL
123 01-192 9/15
Miami Shores Village
r Building Department
10050 NE 2nd Ave.
<ow Miami Shores, FL 33138
305-795-2204 / Fax 305-756-8972
NOTICE TO MIAMI SHORES BUILDING DEPARTMENT OF EMPLOYMENT AS SPECIAL
INSPECTOR UNDER THE FLORIDA BUILDING CODE.
I (We) have been retained by Ricard Prophet to perform special inspector services under the Florida
Building Code 5th Edition (2014) and Miami Dade County Administrative Code at the Prophet Residence
project on the below listed structure as of 10/18/2017 (date). I am a registered
arch itect/professional engineer licensed in the State of Florida.
Process Number: 16-2286
X Special Inspector for Reinforced Masonry, Section 2122.4 of the FBC 5th Edition (2014)
_ Miami Dade County Administrative Code, Article II Section 8-22 Special Inspector for
x Trusses > 35 ft. long or 6 ft. high
Steel Framing and Connections welded or bolted
_ Soil Compaction
_ Precast Attachments
Roofing Applications, Lt. Weight. Insul. Conc.
_ Other
(Vote: Only the marked boxes apply.
The following individual(s) employed by this firm or me is authorized representative to perform
inspection*
1. Marcus Unterwe er 2. Ricardo Madriz
3, Giacomo Stanghellini 4.
*Special inspectors utilizing authorized representatives shall insure the authorized representative is qualified b}
education or licensure to perform the duties assign by Special Inspector. The qualifications shall include licensure as a
professional engineer or architect: graduation from an engineering education program in civil or structural engineering;
graduation from an architectural education program; successful completion of the NCEES Fundamentals Examination;
or registration as building inspector or general contractor.
I (we) will notify the Miami Shores Building Department of any changes regarding authorized personnel
perfonning inspection services.
I (we), understand that a Special Inspector inspection log for each building must be displayed in a
convenient location on the site for reference by the Miami Shores Building Department Inspector. All
mandatory inspections, as required by the Florida Building Code, must be performed by the Miami Shores
Building Department .Inspections performed by the Special Inspector hired by the owner are in addition to
the mandatory inspections performed by the department. Further, upon completion of work under each
Building Permit, I will submit to the Building Inspector at the time of the final inspection the completed
inspection log form and a sealed statement indicating that, to the best of my knowledge, belief and
professi(Wal judgment those portions of the project outlined above ►neet the intent of the Florida Building
ZnWtantial accordance,)Nthah-e apj)r�oval plans.
`4`ao o , U ; J i'4z9 t!..�� Engineer/Architect
i
SF`.�'�•0 Name Marcus Unterweger, P.E., S.I.
Sig d andpealed 3860 '• Print
Date: 10 8 2017 = ddress 3440 NE 12th Avenue
Oakland Park, FL 33334
q
:�•� S
T' .
''41'910NA��� ?`°o
�il�
♦'
MUEngineers, Inc.
3440 NE 12th Avenue
Oakland Park, FL 33334
Phone: (954) 324-4730
CA#:29348
www.MUEnaineers.com
October 11, 2017
Prepared For:
Prepared By:
]"U ngineers, Inc.
MUE PN: MUE16030301
Structural Calculations, Notes and Details
ProphetsResidence
190 NW 101s. Miami Shore, FL 33150
M ngineers, Inc
3440 NE 121h Avenue
Oakland Park, FL 33334
Phone: (954) 324-4730
Fax: (954) 653-4170
www.MUEngineers.com
License No. 29348
ee% U N
%%
86p s
CC
.. -0 TAT
`ss O hd
'•rrrttl�����
THOROUGH, DETAILED AND COST EFFICIENT ENGINEERING DELIVERED IN A TIMELY MANNER
I-
ngineers, Inc
IIIUCA
Page
Wind Load ASCE 7-10
3
Masonry wall Calculation
10
Wall footing Foundation calculation
13
Tie down Trusses Calculations
16
Tie down Truss Simpson Connections
17
u
IIIf°°°I
°°.°GAS o U/vj- �.
63860 ••;
=0' E OF
FA
f+r rl/O�'ti%!_ ENO e As
°0°°°�tttt►tt�`
Marcus Unterweger
Florida P.E.#: 063860
10/11/2017
MUEngineers, Inc.
3440 NE 12th Avenue
Oakland Park, FL 33334
954-324-4730
CA #: 29348
Wind Loads:
Ultimate Wind Speed
Nominal Wind Speed
Risk Category
Exposure Category
Enclosure Classif.
Internal pressure
Directionality (Kd)
Kh easel
Kh case 2
Type of roof
ASCE 7 - 10
175 mph
135.6 mph
II
C
Enclosed Building
+/-0.18
0.85
0.849
0.849
Gable
TODoaraahic Factor (Kzt
Topography
Flat
Hill Height (H)
0.0 ft
Half Hill Length (Lh)
0.0 ft
Actual H/Lh =
0.00
Use H/Lh =
0.00
Modified Lh =
0.0 ft
From top of crest: x =
0.0 ft
Bldg up/down wind?
downwind
H/Lh= 0.00
K, =
0.000
x/Lh = 0.00
K2 =
0.000
z/Lh = 0.00
K3 =
1.000
At Mean Roof Ht:
Kzt = (1+KiK2K3)"2
=
1.00
Gust Effect Factor
h= 15.0 ft
B = 43.0 ft
/z (0.6h) = 15.0 ft
Riaid Structure
e =
0.20
f =
500 ft
Zmin =
15 ft
c =
0.20
9Q, 9v =
3.4
LZ =
427.1 ft
Q =
0.92
Iz =
0.23
G =
0.88 use G = 0.85
JOB TITLE ProphetesResidenceMiamiShores
JOB NO. MUE16030301 SHEET NO.
CALCULATED BY DATE
CHECKED BY DATE
H< 15ft;exp C
.•. Kzt=1.0
ESCARPMENT
V(z) 1
Z46
Speed-up
Z) x(upwind) x(downv Ind)
W2 H
2D RIDGE or 3D AXISYMMETRICAL HILL
Flexible structure if natural frequency < 1 Hz (T > 1 second).
However, if building h/B < 4 then probably rigid structure (rule of thumb).
h/B = 0.35 Rigid structure
G = 0.86 Using rigid structure default
Flexible or Dvnamicaliv Sensitive Structure
Natural Frequency (r)j) =
0.0 Hz
Damping ratio (0) =
0
/b =
0.65
/a =
0.15
Vz =
147.8
N j =
0.00
Rn =
0.000
Rh =
28.282 n = 0.000
RB =
28.282 n = 0.000
Ri- =
28.282 n = 0.000
9R =
0.000
R =
0.000
G =
0.000
h = 15.0 ft
3
MUEngineers, Inc.
3440 NE 12th Avenue
Oakland Park, FL 33334
954-324-4730
CA M 29348
JOB nTLE ProphetesResidenceMiamiShores
JOB NO. MUE16030301
CALCULATED BY
CHECKED BY
Wind Loads - MWFRS h560' (Low-rise Buildings) Enclosed/partially enclosed only
SHEET NO.
DATE
DATE
Kz = Kh (case 1) = 0.85 Edge Strip (a) = 4.3 ft
Base pressure (qh) = 56.6 psf End Zone (2a) = 8.6 ft
GCpi = +/-0.18 Zone 2 length = 21.5 ft
Wind Pressure Coefficients
CASE A
CASE B
9 = 18.4 deg
Surface
GCpf
w/-GCpi
w/+GCpi
GCpf
w/-GCpi
w/+GCpi
1
0.52
0.70
0.34
-0.45
- .27
-0.63
2
-0.69
-0.51
-0.87
-0.69
-0.51
-0.87
3
-0.47
-0.29
-0.65
-0.37
-0.19
-0.55
4
-0.42
-0.24
-0.60
-0.45
-0.27
-0.63
5
0.40
0.58
0.22
6
1
-0.29
-0.11
-0.47
1 E
0.78
0.96
0.60
-0.48
-0.30
-0.66
2E
-1.07
-0.89
-1.25
-1.07
-0.89
-1.25
3E
-0.67
-0.49
-0.85
-0.53
-0.35
-0.71
4E
-0.62
-0.44
-0.80
-0.48
-0.30
-0.66
5E
0.61
0.79
0.43
6E
-0.43
-0.25
-0.61
Ultimate Wind Surface Pressures (psf)
1
39.4 19.0
-15.3 -35.6
2
-28.9 -49.2
-28.9 -49.2
3
-16.3 -36.7
-10.7 -31.1
4
-13.3 -33.7
-15.3 -35.6
5
32.8 12.4
6
1
-6.2 -26.6
1 E
54.3 34.0
-17.0 -37.3
2E
-50.3 -70.7
-50.3 -70.7
3E
-27.9 -48.3
-19.8 -40.2
4E
-24.8 -45.1
-17.0 -37.3
5E
44.7 24.3
6E
-14.1 -34.5
Parapet
Windward parapet = 0.0 psf (GCpn = +1.5)
Leeward parapet = 0.0 psf (GCpn = -1.0)
Horizontal MWFRS Simgle Diaahragm Pressures (Ps
Transverse direction (normal to L)
Interior Zone: Wall 52.7 psf
Roof -12.5 psf *"
End Zone: Wall 79.1 psf
Roof -22.4 psf **
Longitudinal direction (parallel to L)
Interior Zone: Wall 39.0 psf
End Zone: Wall 58.8 psf
** NOTE: Total horiz force shall not be less than that determined
by neglecting roof forces (except for MWFRS moment frames).
The code requires the MWFRS be designed for a min ultimate
force of 16 psf multiplied by the wall area plus an 8 psf force
applied to the vertical projection of the roof.
Windward roof
overhangs = 39.6 psf (upward) add to
windward roof pressure
WINDWARD
OVERHANG (-f-t WINDWARDROOF
LEEWARD ROOF
J!
VERTICAL
8
a
TRANSVERSE ELEVATION
WINDWARD ROOF
i i I 1 j 1 i1�l LEEWARD ROOF
VERTICAL
ZONE 2
LONGITUDINAL ELEVATION
MUEngineers, Inc. JOB TITLE ProphetesResidenceMiamiShores
3440 NE 12th Avenue
Oakland Park, FL 33334 JOB NO. MUE16030301 SHEET NO.
954-324-4730 CALCULATED BY DATE
CA #: 29348 CHECKED BY DATE
Location of MWFRS Wind Pressure Zones
1
E
ZOI%-E 2: lessor of
0.5 B or 2.5 h
If 2 is negative
CASE A t�—X�1',-D D=C="
�T� L1-D DMEC'TIO\
R�\GE
RAGE
NOTE: Torsional loads are 25% of zones 1 - 6. See code for loading diagram.
ASCE 7 -99 and ASCE 7-10 M later)
E 3E\
6
ZO1'E 2: lessor of
,. 0_5 B or 2.5 h
If 2 is negatil
2
g-
M"IMPAPP,
�'
Tranwerse Direction Lonsritudinal Direction
NOTE: Torsional loads are 25% of zones 1 - 4. See code for loading diagram.
CASE B
1
WIND DPI C ON,
5
MUEngineers, Inc.
3440 NE 12th Avenue
Oakland Park, FL 33334
954-324-4730
CA #: 29348
JOB TITLE ProphetesResidenceMiamiShores
JOB NO. MUE16030301 SHEET NO.
CALCULATED BY DATE
CHECKED BY DATE
Ultimate Wind Pressures
Wind Loads - Components & Cladding: h <= 60'
Kh (case 1) = 0.85 h = 15.0 It
Base pressure (qh) = 66.6 psf a = 4.3 It
Minimum parapet ht = 0.0 ft GCpi = +/-0.18
Roof Angle (e) = 18.4 deg
Type of roof = Gable
Roof
Area
Negative Zone 1
Negative Zone 2
Negative Zone 3
Positive All Zones
Overhang Zone 2
Overhang Zone 3
Overhang pressures in the table above assume an internal pressure coefficient (Gcpi) of 0.0
Overhang soffit pressure equals adjacent wall pressure reduced by internal pressure of 10.2 psf
GCp +/- GCpi
Surface Pressure (psf)
User Input
10 sf
50 sf
100 sf
10 sf
50 sf
100 sf
75 sf
500 sf
-1.08
-1.01
-0.98
-61.1
-57.1
-55.4
-56.1
-55.4
-1.88
-1.53
-1.38
-106.4
-86.6
-78.1
-81.6
-78.1
-2.78
-2.36
-2.18
-157.3
-133.5
-123.3
-127.6
-123.3
0.68
0.54
0.48
38.5
30.6
27.2
28.6
27.2
-2.20
-2.20
-2.20
-124.5
-124.5
-124.5
-124.5
-124.5
-3.70
1 -2.86
-2.50
-209.3
-161.9
-141.4
-149.9
-141.4
Parapet
qp = 0.0 psf
CASE A = pressure towards building (pos)
CASE B = pressure away from bklg (neg)
Walls
AreE
Negative Zone A
Negative Zone',
Positive Zone 4 &
Solid Parapet Pressure
Surface Pressure(PSO
User Input
10 sf
100 sf
500 sf
40 sf
,ASE A: Interior zone:
Comer zone:
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
SASE B : Interior zone:
Comer zone:
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
GCp +/- GCpi
Surface Pressure (psf)
User input
10 sf
100 sf
500 sf
10 sf
100 sf
500 sf
40 sf
200 sf
-1.28
-1.10
-0.98
-72.4
-62.4
-55.4
-66.4
-59.4
-1.58
-1.23
-0.98
-89.4
-69.4
-55.4
-77.4
-63.4
1.18
1.00
0.88
66.8
56.8
49.8
60.7
53.8
6
MUEngineen3, Inc. JOB TITLE ProphetesResidenceMiamiShores
3440 NE 12th Avenue
Oakland Park, FL 33334 JOB No. MUE16030301 SHEET NO.
954-324-4730 CALCULATED BY DATE
CA #: 29348 CHECKED BY DATE
Ultimate Wind Pressures
Roofs w/ 0 5 10*
and all walls
h>60'
I
Monoslope roofs
10° < 0 5 30"
h 5 60' & alt design h<90'
8
Location of C&C Wind Pressure Zones
Walls h 5 60'
& alt design h<90'
Multispan Gable &
Gable 7° < e 5 45°
Stepped roofs 6 s 3°
h 5 60' & sit design h<90'
7
rt r
I I I I
21 IZ 01 I
I I L(D
I I I r3 2 —�
Gable, Sawtooth and
Multispan Gable 0 5 7 degrees & Monoslope roofs
Monoslope 5 3 degrees 3° < 0 5 10`
h 5 60' & aft design h<90' h 5 60' & aft design h<90'
L - �
Hip 7° < 0 5 27°
Sawtooth 10* < 0 5 45°
h 5 60' & alt design h<90'
MUEngineers, Inc.
3440 NE 12th Avenue
Oakland Park, FL 33334
954-324-4730
CA #: 29348
JOB TITLE ProphetesResidenceMiamiShores
JOBNO. MUE16030301 SHEET NO.
CALCULATED BY DATE
CHECKED BY DATE
Roof Design Loads
Items
IDescriptlon Multiple
I pSf max
sf min
Roofing
Spanish Tile
19.0
16.0
Roofing
Bituminous membrane, smooth surface
1.5
1.5
Decking
3/4" plywood/OSB
2.7
2.3
Framing
Wood Trusses @ 24" x 2.0
6.0
5.0
Insulation
R-30 Fiberglass insul.
0.9
0.9
Ceiling
5/8" gypsum
2.8
2.5
Mach & Elec
Mech. & Elec.
2.0
0.0
Misc.
Misc.
0.5
0.0
Actual Dead Load
• 35.4
• 28.2
Use this DL instead
25.0
20.0
Live Load
20.0
0.0
Snow Load
0.0
0.0
Ultimate Wind (zone 2 - 100sf)
27.2
-78.1
ASD Loadina D + Lr
55.4
-
D + 0.75(0.6*W + Lr)
62.6
-
0.6*D + 0.6*W
-
-29.9
LRFD Loading 1.2D + 1.6 Lr + 0.5W
88.1
-
1.2D + 1.OW + 0.51-r
79.6
-
0.9D + 1.OW
-
-52.7
Roof Live Load Reduction Roof angle 4.00 / 12 18.4 deg
0 to 200 sf. 20.0 psf
200 to 600 sf: 20.0 psf
over 600 sf: 20.0 psf
300 sf 18.0 psf
400 sf 16.0 psf
500 sf 14.0 psf
User Input: 450 sf 15.0 psf
8
I
MUEngineers, Inc.
3440 NE 12th Avenue
Oakland Park, FL 33334
954-324-4730
CA #: 29348
JOB nTLE ProphetesResidenceMiamiShores
_JOB NO. MUE16030301
CALCULATED BY
CHECKED BY
Floor Design Loads
SHEET NO.
DATE
DATE
Items
Description Multiple
psf (max)
psf (min)
Flooring
3/4" Ceramic tile on 1" mortar
23.0
20.0
Flooring
Carpet & pad x 1.0
1.0
1.0
None
0.0
0.0
None
0.0
0.0
None x 10.0
0.0
0.0
None
0.0
0.0
None
0.0
0.0
None
0.0
0.0
None
0.0
0.0
Actual Dead Load
• 24.0
• 21.0
Use this DL instead
D 25.0
20.0
15.0
0.0
Partitions
Live Load
0.0
0.0
15.0
0.0
Total Live Load
39.0
21.0
Total Load
FLOOR LIVE LOAD REDUCTION (not including Partitions)
NOTE: Not allowed for assembly occupancy or LL>100psf or passenger car
garages, except may reduce columns 20% if 2 or more floors & non -assembly
L=Lo(0.25+15/gKLLAT)
Unreduced design live load: Lo = 0 psf
Floor member KLL =
2
Tributary Area AT =
300 sf
Reduced live load: L =
0.0 psf
Columns (2 or more floors) Ku =
4
Tributary Area AT =
500 sf
Reduced live load: L =
0.0 psf
IBC alternate Procedure
Smallest of:
R= .08%(SF -150)
R= 23.1(1+D/L) = #DIV/0!
R= 40% beams; 60% columns
R = #DIV/0!
Reduced live load: L = #DIV/0!
R = #DIV/0!
Reduced live load: L = #DIV/0!
9
Masonry Slender Wall
r.�r•
Description: Masonry Wall
Code References
Calculations per ACI 530-11, IBC 2012, CBC 2013, ASCE 7-10
Load Combinations Used: ASCE 7-10
General Information
Construction Type: Grouted Hollow Concrete Masonry
F'm = 1.50 ksi
Nom. Wall Thickness
Fy - Yield = 60.0 ksi
Actual Thickness
Fr - Rupture = 61.0 psi
Rebar "d" distance
Em = fm ` = 900.0
Lower Level Rebar ...
Max % of p bal. = 0.006794
Bar Size #
Grout Density = 140 pcf
Bar Spacing
Block Weight Normal Weight
Wall Weight = 58.0 psf
Wall is grouted at rebar cells only
One -Story Wall Dimensions
_
A Clear Height = 13.50 ft
B
B Parapet height = ft
Wail Support Condition Top Pinned, Bottom F
—�
—
Vertical Loads
Vertical Uniform Loads ... (Applied per foot of Ship Width)
Ledger Load Eccentricity in
Concentric Load
Lateral Loads
= P.VAdivelMUE16030301S&ProphetsResidermMlamiShores"e mue16030301.ec6
ENERCALC, INC.1983-2015, Build:6.15.10.6, Ver:6.15.10.6
Calculations per ACI 530-11, IBC 2012, CBC 2013, ASCE 7-10
8 in Temp Diff across thickness = deg F
7.625 in Min Allow Out -of -plane Dell Ratio = 0
3.750 in Minimum Vertical Steel % = 0.0020
5
32.0 in
DL : Dead Lr : Roof Live Lf : Floor Live S : Snow W : Wind
0.480 0.40 k/ft
k/ft
Wind Loads: Seismic Loads:
Full area WIND load 75.0 psf Wall Weight Seismic Load Input Method
Fp 1.0 = 25.0 psf Seismic Wall Lateral Load
Direct entry of Lateral Wall Weight
25.0 psf
10
Mason Slender Wall File=P:AtivelMUE16030301SB-Propt�etsResWenosMiam!Shores\eng\muel603O301.ec6
Masonry ENERCALC, INC.1983-2015, Build:6.15.10.6, Ver.6.15.10.6
Description: Masonry Wall
DESIGN SUMMARY
Results reported for "Strip Width" of 12.0 in
Governing Load Combination ...
Actual Values ...
Allowable Values ...
PASS Moment Capacity Check
Maximum Bending Stress Ratio
= 0.8698
+1.20D+0.50Lr+0.50L+W+1.60H
Max Mu
-1.659 k-ft Phi * Mn
1.908 k-ft
PASS Service Deflection Check
Actual Defl. Ratio U
351
Allowable Defl. Ratio
150
W Only
Max. Deflection
0.4618 in
PASS Axial Load Check
Max Pu / Ag
36.124 psi Max. Allow. Defl.
1.080 in
+1.20D+0.50Lr+0.50L+W+1.60H
Location
0.2250 ft
0.2 * fm
300.0 psi
PASS Reinforcing Limit Check
Controlling As/bd
0.00250
As/bd006794 rho bal 0.006794
PASS Minimum Moment Check
Wracking
0.5935 k-ft Minimum Phi Mn
2.120 k-ft
+1.40D+1.60H
Maximum Reactions ...
for Load Combination....
Top Horizontal
W Only
0.3828 k
Base Horizontal
W Only
0.6297 k
Vertical Reaction
+D+Lr+H
1.663 k
Design Maximum Combinations • Moments
Results reported for "Strip Width" =12 in.
Axial Load
Moment Values
0.6 *
Load Combination
Pu 0.2*fm*b*t
Mcr Mu Phi
Phi Mn
As As Ratio rho bal
k
k
k-ft k-ft
k-ft
in12
0.000
0.000
0.00 0.00 0.00
0.00
0.000 0.0000 0.0000
0.000
0.000
0.00 0.00 0.00
0.00
0.000 0.0000 0.00W
0.000
0.000
0.00 0.00 0.00
0.00
0.000 0.0000 0.0000
0.000
0.000
0.00 0.00 0.00
0.00
0.000 0.0000 0.0000
+1.20D+1.60Lr+0.50W+1.60H at 0.00 to 0.45
0.000
17.640
0.46 1.28 0.90
1.91
0.116 0.0025 0.0068
0.000
0.000
0.00 0.00 0.00
0.00
0.000 0.0000 0,0000
+1.20D+1.60S+0.50W+1.60H at 0.00 to 0.45
0.000
17.640
0.46 1.29 0.90
1.91
0.116 0.0025 0.0068
+1,20D40.50Lr+0.50L+W+1.60H at 0.00 to 0.
0.000
17.640
0.46 1.66 0.90
1.91
0.116 0.0025 0.0068
+1.20D+0.50L40.50S+W+1.60H at 0.00 to 0.4
0.000
17.640
0.46 1.66 0.90
1.91
0.116 0.0025 0.0068
+1.20D+0.50L+0.20S+E+1.60H at 0.00 to 0.4
0.000
17.640
0.46 0.57 0.90
1.91
0.116 0.0025 0.0068
+0.90D4W40.901-1 at 0.00 to 0.45
0.000
17,640
0.46 1.66 0.90
1.91
0.116 0.0025 0.0068
40.90D+E+0.90H at 0.00 to 0.45
0.000
17.640
0.46 0.57 0.90
1.91
0.116 0.0025 0.0068
Design Maximum Combinations • Deflections
Results reported for "Strip Width" =12 in.
Axial Load
Moment Values
Stiffness
Deflections
Load Combination
Pu
Mcr
Mactual I gross
I cracked
I effective Deflection Defl. Ratio
k
k-ft
k-ft :n14
n14
in^4 in
0.000
0.00
0.00 0.00
0.00
0.000 0.000
0.0
0.000
0.00
0.00 0.00
0.00
0.000 0.000
0.0
0.000
0.00
0.00 0.00
0.00
0.000 0.000
0.0
0.000
0.00
0.00 0.00
0.00
0.000 0.000
0.0
0.000
0.00
0.00 0.00
0.00
0.000 0.000
0.0
0.000
0.00
0.00 0.00
0.00
0.000 0.000
0.0
+D+0.60W+H at 8.10 to 8.55
0.793
0.46
0.36 342.40
26.73
342.400 0.101
1,605.4
+D+0.70E+H at 7.65 to 8.10
0.819
0.46
0.22 342.40
26.80
342.400 0.012
13,758.2
+D40.750Lr40.750L+0.450W+H at 7.65 to 8.1
1.119
0.46
0.28 342.40
27.60
342.400 0.049
3,283.5
40+0.750L+0.750S+0.450W+H at 7.65 to 8.10
0.819
0.46
0.28 342.40
26.80
342.400 0.050
3,256.0
+D+0.750L40.750S+0.5250E+H at 7.65 to 8.1
0.819
0.46
0.17 342.40
26.80
342.400 0.009
18,344.2
+0.60D40.60W+0.60H at 8.10 to 8.55
0.476
0.46
0.36 342.40
25.87
342.400 0,102
1,590.0
+0.60D+0.70E40.60H at 7.65 to 8.10
0.492
0.46
0.22 342.40
25.91
342.400 0.012
13,769.9
0.000
0.00
0.00 0.00
0.00
0.000 0.000
0.0
0.000
0.00
0.00 0.00
0.00
0.000 0.000
0.0
0.000
0.00
0.00 0.00
0.00
0.000 0.000
0.0
11
it
Mason Slender Wall
Rle=P:VAdWetMUE16030301-SBRmphetsResidenceMiamiShoresleng\muel6030301.ec6
ENERCALC, INC.1983-2015, Bulld:6.15.10.6, Ver.6.15.10.6
Description: Masonry Wall
Design Maximum Combinations -
Deflections
Results reported for "Strip Width' = 12 in.
Axial Load
Moment Values
Stiffness
Deflections
Load Combination
Pu
Mcr
Mactual
I gross
I cracked I effective
Deflection Dell. Ratio
k
k-ft
k-ft
in"4
in14 in14
in
0.000
0.00
0.00
0.00
0.00 0.000
0.000 0.0
W Only at 7.65 to 8.10
0,000
0.46
0.96
342.40
24.55 25.241
0.462 350.8
E Only at 7.65 to 8.10
0.000
0.46
0.32
342.40
24.55 342.400
0.017 9,651.2
0.000
0.00
0.00
0.00
0.00 0.000
0.000 0.0
Reactions - Vertical & Horizontal
Results reported for "Strip Width' =12 in.
Load Combination
Base Horizontal
Top Horizontal
Vertical @ Wall Base
+D+H
0.0
k
0.00 k
1.263 k
+D+L+H
0.0
k
0.00 k
1.263 k
+D+U+H
0.0
k
0.00 k
1.663 k
+D+S+H
0.0
k
0.00 k
1.263 k
+O+0.750Lr+0.750L+H
0.0
k
0.00 k
1.563 k
+O+0.750L+0.750S+H
0.0
k
0.00 k
1.263 k
+D+0.60W+H
0.4
k
0.19 k
1.263 k
+D+0.70E+H
0.1
k
0.09 k
1.263 k
+D+0.750Lr+0.750L+0.450W+H
0.3
k
0.14 k
1.563 k
+O+0.750L+0.750S+0.450W+H
0.3
k
0.14 k
1.263 k
+D+0.750L+0.750S+0.5250E+H
0.1
k
0.07 k
1.263 k
+0.60D+0.60W+0.60H
0.4
k
0.19 k
0,758 k
+0.60D+0.70E+0.60H
0.1
k
0.09 k
0.758 k
D Only
0.0
k
0.00 k
1.263 k
Lr Only
0.0
k
0.00 k
0.400 k
L Only
0.0
k
0.00 k
0.000 k
S Only
0.0
k
0.00 k
0.000 k
W Only
0.6
k
0.38 k
0.000 k
E Only
0.2
k
0.13 k
0.000 k
H Only
0.0
k
0.00 k
0.000 k
12
Wall Footing
Description: Wall Footing
Code References
Calculations per ACI 318-11, IBC 2012, CBC 2013, ASCE 7-10
Load Combinations Used: ASCE 7-10
General Information
INC.1983-2015, Buiki:6.15.10.6, Ver.6.15.10.6
Material Properties
Soil Design Values
fc : Concrete 28 day strength
= 3.0 ksi
Allowable Soil Bearing =
1.50 ksf
fy : Rebar Yield
= 60.0 ksi
Increase Bearing By Footing Weight =
No
Ec : Concrete Elastic Modulus
= 3,122.0 ksi
Soil Passive Resistance (for Sliding) =
250.0 pc
Concrete Density
= 145.0 pcf
Soil/Concrete Friction Coeff. =
0.30
N Values Flexure
= 0.90
Shear
= 0.750
Increases based on footing Depth
Analysis Settings
Reference Depth below Surface
ft
Min Steel % Bending Reinf.
=
Allow. Pressure Increase per foot of depth -
ksf
Min Allow % Temp Reinf,
= 0.00180
when base footing is below =
ft
Min. Overturning Safety Factor
= 1.0 :1
Increases based on footing Width
Min. Sliding Safety Factor
= 1.0 :1
Allow. Pressure Increase per foot of width =
ksf
AutoCalc Footing Weight as DL
Yes
when footing is wider than =
ft
Dimensions
Reinforcing
Footing Widt =
2.0 ft Footing Thicknes
= 12.0 in Bars along X-X AxiE
Wall Thickness =
6.0 in Rebar Centerline to Edge of Concrete. Bar spacing
= 12.00
Wall center offset
at Bottom of footing = 3.0 in Reinforcing Bar Size
= # 5
from center of footing =
0 in
I#bars 0 12 in o .
led Loads
D Lr L S W E H
P : Column Load = 1.50 0.40 k
OB : Overburden = ksf
V-x = 0.30 k
M-zz = k-ft
Vx applied = in above top of footing
DESIGN SUMMARY e - •
Min. Ratio Item Applied Capacity Governing Load Combination
PASS
0.8299
Soil Bearing
1.245 ksf
1.50 ksf
+D+0.750Lr+0.750L+0.
PASS
6.967
Overturning - Z-Z
0,180 k-ft
1.074 k-ft
+0.60D+O.60W+0.60H
PASS
1.790
Sliding - X-X
0.180 k
0.3222 k
+0.60D+0.60W+0.60H
PASS
n/a
Uplift
0.0 k
0.0 k
No Uplift
PASS
0.03623
Z Flexure (+X)
0.4395 k-ft
12.131 k-ft
+1.20D+1.60Lr+0.50W+
PASS
0.01868
Z Flexure (-X)
0.2265 k-ft
12.131 k-ft
+0.90D+E+0.901-1
PASS
n/a
1-way Shear (+X)
0.0 psi
82.158 psi
n/a
PASS
0.0
1-way Shear (-X)
0.0 psi
0.0 psi
n/a
13
Wall Footing Fie=P:lAci%\MUE16030301-SB-PmphetsRes&-noeMiamiShoreslerglmue16030301.eo6
9 ENERCALC, INC. 1963-2015, Buik1:6.15.10.6, Ver.6.15.10.6
I MUM
IrM
Description: Wall Footing
Detailed Results
Soil Bearing
Rotation Axis & Actual Soil Bearing Stress Actual I Allowable
Load Combination... Gross Allowable Xecc Zecc +Z +Z -X -X Ratio
+D+H
1.50 ksf
0.0 in
0,8950 ksf
0.8950 ksf
0.597
+D+L+H
1.50 ksf
0.0 in
0.8950 ksf
0.8950 ksf
0.597
+D+Lr+H
1.50 ksf
0.0 in
1,095 ksf
1.095 ksf
0.730
+D+S+H
1.50 ksf
0.0 in
0.8950 ksf
0.8950 ksf
0.597
+D+0.750Lr+0.750L+H
1.50 ksf
0.0 in
1.045 ksf
1,045 ksf
0.697
+D+0.750L+0.750S+H
1.50 ksf
0.0 in
0.8950 ksf
0.8950 ksf
0.597
+D+0.60W+H
1.50 ksf
1.207 in
0.6286 ksf
1.161 ksf
0.774
+D+0.70E+H
1.50 ksf
0.0 in
0.8950 ksf
0.8950 ksf
0.597
+D+0.750Lr+0.750L+0.450W+H
1.50 ksf
0.7751 in
0.8452 ksf
1.245 ksf
0.830
+D+0.750L+0.750S+0.450W+H
1.50 ksf
0.9050 in
0.6952 ksf
1.095 ksf
0.730
+D+0.750L+0,750S+0.5250E+H
1.50 ksf
0.0 in
0.8950 ksf
0.8950 ksf
0.597
, +0.60D+0.60W+0.60H
1.50 ksf
2.011 in
0.2706 ksf
0.8034 ksf
0.536
, +0.60D+0.70E+0.60H
1.50 ksf
0.0 in
0.5370 ksf
0.5370 ksf
0.358
Overturning Stability
Units: k-ft
Rotation Axis &
Load Combination...
Overturning Moment
Resisting Moment Stability Ratio
Status
+D+H
None
0.0 k-ft
Infinity
OK
+D+L+H
None
0.0 k-ft
Infinity
OK
+D+Lr+H
None
0.0 k-ft
Infinity
OK
+D+S+H
None
0.0 k-ft
Infinity
OK
+D+0.750Lr+0.750L+H
None
0.0 k-ft
Infinity
OK
+D+0.750L+0.750S+H
None
0.0 k-ft
Infinity
OK
+D+0.60W+H
0.180 k-ft
1.790 k-ft
9.944
OK
+D+0.70E+H
None
0.0 k-ft
Infinity
OK
+D+0.750Lr+0.750L+0.450W+H
0.1350 k-ft
2.090 k-ft
15.481
OK
+D+0.750L+0.750S+0.450W+H
0.1350 k-ft
1.790 k-ft
13.259
OK
+D+0.750L+0.750S+0.5250E+H
None
0.0 k-ft
Infinity
OK
, +0.60D+0.60W+0.60H
0.180 k-ft
1.074 k-ft
5.967
OK
, +0.60D+0.70E+0.60H
None
0.0 k-ft
Infinity
OK
Sliding Stability
Force Application Axis
Load Combination...
Sliding Force
Resisting Force
Sliding SafetyRatio
Status
+D+H
0.0 k
0.5370 k
No Sliding
OK
+D+L+H
0.0 k
0.5370 k
No Sliding
OK
+D+Lr+H
0.0 k
0.6570 k
No Sliding
OK
+D+S+H
0.0 k
0.5370 k
No Sliding
OK
+D+0.750Lr+0.750L+H
0.0 k
0.6270 k
No Sliding
OK
+D+0.750L+0.750S+H
0.0 k
0.5370 k
No Sliding
OK
+D+0.60W+H
0.180 k
0.5370 k
2.983
OK
+D+0.70E+H
0.0 k
0.5370 k
No Sliding
OK
+D+0,750Lr+0.750L+0.450W+H
0.1350 k
0.6270 k
4.644
OK
+D+0.750L+0.750S+0.450W+H
0.1350 k
0.5370 k
3.978
OK
+D+0.750L+0.750S+0.5250E+H
0.0 k
0.5370 k
No Sliding
OK
, +0.60D+0.60W+0.60H
0.180 k
0.3222 k
1.790
OK
, +0.60D+0.70E+0.60H
0.0 k
0.3222 k
No Sliding
OK
Footing Flexure
Flexure Axis &Load Combination
Mu Which Tension @ Bot. As Req'd
Gvrn. As
Actual As Phi*Mn
k-ft Side ? or Top ? in^2
in"2
in^2
k-ft Status
+1.40D+1.60H
0.3524
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.40D+1.60H
0.3524
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50Lr+1.60L+1.60H
0.3302
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50Lr+1.60L+1.60H
0.3302
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60L+0.50S+1.60H
0.3021
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60L+0.50S+1.60H
0.3021
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60Lr+0.50L+1.60H
0.3921
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60Lr+0.50L+1.60H
0.3921
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60Lr+0.50W+1.60H
0.3446
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60Lr+0.50W+1.60H
0.4395
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50L+1.60S+1.60H
0.3021
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
14
Wall Footing File=P.bAdiveWUE16030301-SB-P"tsResfdenceMiamiShoreslenglmue16030301.ec6
9 ENERCALC, INC.1983-2015, 8uild:6.15.10.6, Ver.6.15.10.6
Description: Wag Footing
Footing Flexure
Flexure Axis & Load Combination Mu Which Tension @ Bot. As Req'd Gvrn. As Actual As Phi*Mn
k-ft Side ? or Top ? in^2 in^2 in^2 k-ft Status
+1.20D+0.50L+1.60S+1.60H
0.3021
+X
Bottom
0,2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60S+0.50W+1.60H
0.2546
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+1.60S+0.50W+1.60H
0.3495
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50Lr+0.50L+W+1.60H
0.2353
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50Lr+0.50L+W+1.60H
0.4251
+X
Bottom
0,2592
Min Temp %
0.31
12.131
OK
, +1.20D+0.50L+0.50S+W+1.60H
0.2072
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
, +1.20D+0.50L+0.50S+W+1.60H
0.397
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
+1.20D+0.50L+020S+E+1.60H
0.3021
-X
Bottom
0,2592
Min Temp %
0.31
12,131
OK
+1.20D+0.50L+0.20S+E+1.60H
0.3021
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
, +0.90D+W+0.90H
0.1316
-X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
, +0.90D+W+0.90H
0,3214
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
, +0.90D+E+0.90H
0.2265
-X
Bottom
0,2592
Min Temp %
0.31
12.131
OK
,+0.90D+E+0.90H
0.2265
+X
Bottom
0.2592
Min Temp %
0.31
12.131
OK
One Way Shear
Units: k
Load Combination...
Vu CrD. -X
Vu CCD. +X
Vu:Max
Phi Vn
Vu 1 Phi*Vn
Status
+1.40D+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+0.50Lr+1.60L+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+1.60L+0.50S+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+1.60Lr+0.50L+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+1.60Lr+0.50W+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+120D+0.50L+1.60S+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+1.60S+0.50W+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+0.50Lr+0.50L+W+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+0.50L+0.50S+W+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+1.20D+0.50L+0.20S+E+1.60H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+0.90D+W+0.90H
0 psi
0 psi
0 psi
82.158 psi
0
OK
+0.90D+E+0.90H
0 psi
0 psi
0 psi
82.158 psi
0
OK
15
3:05 PM
10/7/2016
Im
ngineers, Inc.
www.MUEngineers.com Tie Down Trusses Calculations
GT
OVER HANG LENGTH
ZOON2
ZOON2
LENGTH(FEET)
2.5
15
WIDTH(FEET)
4.125
4.125
AREA
10.3125
61.875
WIND PRESSURE
-128
-128
UPLIFT
-1318
-7908
TOTAL UPLIFT
-9226
DEAD LOAD
722
TOTAL TIE DOWN CONNECTION "A"
UPLIFT FORCE(0.6DI+0.6WIND)
-2334.54375
HT
OVER HANG LENGTH
ZOON3
ZOON3
ZOON2
OVER HANG
LENGTH ZOON2
LENGTH(FEET)
8.6
4.3
4
2
WIDTH(FEET)
1.25
4.3
2
1.3
AREA
10.75
18.49
8
2.6
WIND PRESSURE
-215
-151
-100
-19
UPLIFT
-2310
-2792
-803
-50
TOTAL UPLIFT/2
-2978
DEAD LOAD
436
rTOTAL TIE DOWN CONNECTION "B"
UPLIFT FORCE(DI+0.6WIND)
-1350.2355
JT
OVER HANG LENGTH
ZOON2
ZOON2
LENGTH(FEET)
1.25
5
WIDTH(FEET)
2
2
AREA
2.5
30
WIND PRESSURE
-128
-109
UPLIFT
-320
-1092
TOTAL UPLIFT IN CONNECTION
-866
DEAD LOAD
188
TOTAL TIE DOWN CONNECTION "C"
UPLIFT FORCE(DI+0.6WIND)
-332
T
OVER HANG LENGTH
ZOON2
ZOON2
LENGTH(FEET)
4.75
5
WIDTH(FEET)
2
2
AREA
9.5
10
WIND PRESSURE
-128
-109
UPLIFT
-1214
-1092
TOTAL UPLIFT IN CONNECTION
-1760
DEAD LOAD
57
60
AL TIE DOWN CONNECTION "D"
UPLIFT FORCE(DI+0.6WIND)
r
999
P:\AUUIveWUE16030301-S6ProphetsResidenceMiamiShwesbnOWIUE16030301-TIEDOM TRUSS CALCULATION
16
Mark on Plan
Anchor / Connector Type
FASTENERS
TO TRUSS
A
Simpson MGT
(22) 10 d Nails
B
Simpson HETA16
(9) 10d x 1 1/2"Nail
C
Simpson META 16
(7) 10d x 1 1/2"Nail
D
Simpson META6
1(7) 10 d x 1 1/2" Nails
17