FW-18-3764Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
Location Address
_ Permit No.: FWA 2.18-3764
Permit Type: Fence/Wall
Work Classification: PVC
Permit Status: Approved
Issue Date:12/27/2018' Expiration: 06/25/2019
Parcel Number
195 NW 91ST ST, Miami Shores, FL 33150 1131010000190
Contacts
ERIC BANCROFT Owner DANELLE BANCROFT Owner
195 NW 91 ST, MIAMI SHORES, FL 33150
Other:3057133344 Other:3054971981
HOME OWNER Contractor
HOME OWNER
Description: FENCE VINYL 6 FOOT TALL Valuation: $ 6,500.00 Inspection Requests:
Total Scl Feet: 0.00 11
Fees
Amount
Application Fee - Other
$50.00
CCF
$4.20
DBPR Fee
$3.36
DCA Fee
$2.24
Education Surcharge
$1.40
Notary Fee
$5.00
Planning and Zoning Review Fee
$35.00
Scanning Fee
$12.00
Structural Review ($45)
$45.00
Technology Fee
$5.60
Wire and Wood Fence Fee
$174.00
Total:
$337.80
Building Department Copy
Payments
Date Paid Amt Paid
Total Fees
$337.80
Credit Card
12/27/2018 $337.80
Amount Due:
$0.00
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this per it I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELVC RICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I �ce,4fy that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
regulating constr�ign an z ing. Futhermore, I authorize the above named contractor to do the work stated.
Signature: Owner / Applicant / Contractor / Agent Date
December 27, 2018 Page 2 of 2
e
BUILDING
PERMIT APPLICATION
Miami Shores Village JZEC�'F'T`zr'
Building Department ti C 212018
10050 N.E.2nd Avenue, Miami Shores, Florida 33138 BY:
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949 l
FBC 20 C�
Master Permit No." (e Eq (-1
Sub Permit No.
BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF [:]CANCELLATION ❑ SHOP
G � CONTRACTOR DRAWINGS
G1 JOB ADDRESS: I l S ��A.I T
City: Miami Shores County: Miami Dade Zip:
Folio/Parcel#: Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): EfuL &WWAiz--r Phone#: 3Us- 7 / 3— &3 7 "l
Address: 115 AA) ` 1:51
City: /i'/I N4 % SAvr( lCS State: ECG Zip. �/S O
Tenant/Lessee Name: /-� Phone#: 3US— 7 IS—,33V(I
Email:��G�X•iyG/�`i
CONTRACTOR: Company Name: yQmfok-m"ne Phone#:
Address:
City:
Qualifier Name:
State Certification or Registration #:
Zip:
Phone#:
Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address: / City: State: Zip:
Value of Work for this Permit: $ D 500 ' co c) Square/Linear Footage of Work: 121 i�
7
Type of Work: ❑ Addition ❑ Alteration ❑ New Repair/Replace ❑ Demolition
Description of Work: Ff,—,ij ` V%yL " K Ergs- ?AZl,
Specify color of color thru the W14 176 `
Submittal Fee $ IOC Permit Fee $ CCF $ . CO/CC.$ .
Scanning Fee $ Radon Fee $ DBPR $ Notary $
Technology Fee $
Structural Reviews $
Training/Education Fee $
Double Fee $
Bond $
TOTAL FEE NOW DUE $ S3-� • R-7
(Revised02/24/2014)
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature�c A Signature
OWNER or AGENT CONTRACTOR
The foregoing instrument was acknowledged before me this
^�-- �� day of ���0 �(V�EI� , 20 by
CCU C60rw ha is personally known to
me or who has produced -R-bellk e- Lx-G�7�9-%-s
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
The foregoing instrument was acknowledged before me this
day of 20, by
, who is personally known to
me or who has produced
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print: S, CADIPPrint:
r.
SINDIA ALVAREZ Seal:
t' MY COMMISSION # GG 238273
EXPIRES: September 3, 2022
Bonded Ttwu Notary Pubac Underwriters
as
APPROVED BY Plans Examiner Zoning
�Y Structural Review Clerk
(Revised02/24/2014)
Property Search Application - Miami -Dade County Page 1 of 1
OFFICE OF THE ter.. PROPERTY
APPRAISER
Summary Report
Property Information
Folio:
11-3101-000-0190
195 NW 91 ST
Property Address:
Miami Shores, FL 33150-2256
ERIC BANCROFT
DANELLE BANCROFT
Owner
EDWARD JACKSON
KIM JACKSON
195 NW 91 ST
Mailing Address
MIAMI SHORES, FL 33150 USA
PA Primary Zone
0800 SGL FAMILY - 1701-1900 SQ
0101 RESIDENTIAL - SINGLE
Primary Land Use
FAMILY: 1 UNIT
Beds / Baths / Half
3/3/0
Floors
.._.............
1
Living Units
1
Actual Area
3,212 Sq.Ft
Living Area
2,678 Sq.Ft
Adjusted Area
2,715 Sq.Ft
Lot Size
13,200 Sq.Ft
........... ................. .............. . .
Year Built
1959
Assessment Information
Year
2018
2017.2016
Land Value
$290,690
$290,690 $290,690
Building Value
XF Value
$152,719
$4,398
$141,723 $141,723
$4,424 $4,449
Market Value
$447,8071
$436,837 $436,862
Assessed Value
$419,488
$381,353 $346,685
Benefits Information
Benefit Type 2018 2017 2016
............................................. V_
Non -Homestead Assessment
$28,319 $55,484 $90,177
Cap Reduction
Note: Not all benefits are applicable to all Taxable Values (i.e. County,
School Board, City, Regional).
Short Legal Description
1 53 41 .29 AC M/L
W135FT OF S1/2 OF SW1/4 OF NW1/4
OF SE1/4 LESS W35FT & S35FT FOR
ST & LESS N169.25FT THEREOF
LOT SIZE 100.000 X 132
Generated On : 12/27/2018
Taxable Value Information
2018'', 201T
2016
County
Exemption Value
$0
$0
$0
Taxable Value
1 $419,488
$381,353
$346,685
School Board
Exemption Value
$0
$0
$0
Taxable Value
$447,807
$436,837
$436,862
City
Exemption Value
$0
$0
$0
Taxable Value
$419,488
$381,3531
$346,685
Regional
Exemption Value
.....................................
Taxable Value
$0
__..._._..........................................._......_
$419,4881
$0
_._
$381,353
$0
_ .._......_........_........ ...........
$346,685
Sales Information
Previous
OR Book -
Price
Qualification Description
Sale
Page
31037-
Corrective, tax or QCD; min
06/22/2018
$0
'1316 -
considerations
30999
05/25/2018
$450,000
Qual by exam of deed
1065
26887
... _.._ ...............
05/26/2009
$280,000
Qual by exam of deed
3946
00000-
Sales which are disqualified as a result
09/01/1991
$0
00000
of examination of the deed
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at hftp://w\&w.miamidade.gov/info/disclaimer. asp
Version:
https://www.miamidade.gov/propertysearch/
12/27/2018
Miami Shores Village
Building Department
10050 N.E.2nd Avenuz
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNER BUILDER DISCLOSURE STATEMENT
NAME: 2S 2IC. &AA) rklEr DATE: / Z�1,27 16n/p
ADDRESS: JiS ",.) ! % Sf S-" 3315G
Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have
read and understood the following disclosure statement, which entitles me to work as my own contractor; I further understand that I as the owner
must appear in person to complete all applications.
State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption
allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the
construction yourself. You may build or improve a one -family or two-family residence. You may also build or improve a commercial building at a
cost of $25,000.00 or less (The new form states 75,000). The building must be for your own use and occupancy. It may not be built for sale or
lease. if you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built
for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make
sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on
your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and
with -holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all
applicable laws, ordinances, buildings codes and zoning regulations.
Please read and initial each paragraph.
1. I understand that state law requires construction to be done by a licensed contractor and have applied for an owner -builder permit under an
exemption from the law. The exemption specifies that I, as the owner of the property listed, may act as my own contractor with certain
restrictions even though I do not have a license.
Initial
2. 1 understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and
is not hiring a licensed contractor to assume responsibility.
Initial
3. 1 understand that, as an owner builder, I am the responsible party of record on a permit. I understand that I may protect myself from potential
financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that the
contractor is required by law to be licensed in Florida and to list his or license numbers on permits and contracts.
Initial
4. 1 understand that I may build or improve a one family or two-family residence or a farm outbuilding. I may also build or improve a commercial
building if the costs do not exceed $75,000. The building or residence must be for my use or occupancy. It may not be built or substantially
improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within 1 year after the
construction is complete, the law will presume that I built or substantially improved it for sale or lease, which violates the exemption.
Initial
5. i understand that, as the owner -builder, I must provide direct, onsite supervision of the construction.
Initial
6. 1 understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence. It
is my responsibility to ensure that the persons whom I employ have the license required by law and by county or municipal ordinance.
Initial
�
7. i understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner -builder permit that erroneously
implies that the property owner is providing his or her own labor and materials. I, as an owner -builder, may be held liable and subjected to
serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's
insurance may not provide coverage for those injuries. I am willfully acting as an owner -builder and am aware of the limits of my insurance
coverage for injuries to workers on my property.
Initial
8. 1 understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the
work being done. Any person working on my building who is not licensed must work under my direct supervision and must be employed by
me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the
Federal Insurance Contributions Act (FICA) and must provide workers compensation for the employee. I understand that my failure to follow
these may subject to serious financial risk.
Initial
9. 1 agree that, as the party legally and financially responsible for this proposed Construction activity, I will abide by all applicable laws and
requirement that govern owner -builders as well as employers. I also understand that the
Construction must comply with all applicable laws, ordinances, building codes, and zoning regulation
c.
Initial
10. 1 understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service, the United States
Small Business Administration, and the Florida Department of Revenues. I also understand that I may contact the Florida Construction Industry
Licensing Board at 850.487,1395 or http://www.myfloridalicense.com/dbpr/pro/cilb/index.html
Initial. Ln, _
11. I am aware of, and consent to; an owner -builder building permit applied for in my name and understands that I am the party
legally and financially responsible for the proposed construction activity at the following address:
175 tiw 9/ St 57' 331s6
Initial_
12. 1 agree to notify Miami Shores Village immediately of any additions, deletions, or changes to any of the information that I have provided on
this disclosure.
Initial
Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the
Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial
loss that you sustain as a result of contractor may be in civil court. It is also important for you to understand that, if an unlicensed contractor or
employee of an individual or firm is injured while working on your property, you may be held liable for damages. If you obtain an owner -builder
permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is properly licensed and the status of
the contractor's workers compensation coverage.
Before a building permit can be issued, this disclosure statement must be completed and signed by the property owner and returned to the local
permitting agency responsible for issuing the permit. A copy of the property owner's driver license, the notarized signature of the property
owner, or other type of verification acceptable to the local permitting agency is required when the permit is issued.
Was acknowledged before me this Z.74 day of_P_1F-_' Mom; 20 ! b
By l-� e &3 N ce-G-PT who was personally known to me or who. has
Produced there License r l�`D�- l�tZ Uk. N a as identification.
_- 'A
OWNER NOTARY
c1eNl owun mend AMOK W41 PaPuo9 0 o�i
ZZOZ'E jKwaldaS :S3'dldX3
£LZ8£Z JJ # NOISSINInoci An
Z321VA111 diONIS 3a:1 �
w IMF,cen•�w.°.AI°9°9
PaR e°•A
NaM-°e-wm
��h [o�em•.t
11.:k Rw,a�te,
Li3 0• � rt�rw F-3
�3,E �M.RwM PW.
Ps
8 care
�fnow Mk 9W Ni
• 0.a
O•clh
® D�•c14e
e f%
� EV•�xp,w1
® Go
® cre•
M
0 •.IF•4u° vanba vM
M n�wMe •
ai tgNnt Pd
eM
v. R`e•.I meV re,I
xA Or,r r•e W,wI
A� 9Pai Cm,a 9v
�iw•umi v.i.
Ar �w wq am
]}AyHB�[L,, s�rugM
A�®® SoiaY Pew KmMYe
-, •rn uaixW
B T m
0 T.N�p,une Bo.
5 n
i,+pe Spot fared &e
�(. wom UWA Pd.
O wooa Po.ar PM•
. . ... . . . ...
.. .. . . . .. .. .
. . . . . . . . . .
"" ' " " "BUONDARY SURVEY
A PORTION OF THE SW 1/4 OF SECTION 1, TOWNSHIP 53 SOUTH, RANGE
41 EAST, MIAMI SHORES VILLAGE, MIAMI—DADE COUNTY, FLORIDA.
•• • • • • • •• • •
K
• ••• • • • • •• •
NW 92 �TRCE7• • • • •
POC (FND. N&D) V
NW CORNER OF THE 17 1F OF THE
SW 1/4 OF THE NW i/4 OF THE SE
1/4 OF SECTON 1-53S-41E m GIMPING 9CA18 w
HomT.— —
HOMED
1 (Pe, PG.B. 39, PG. 98)
x = V GATi5
X ` S ' GATr5
A PORTION OF THESE 1I4 OF SECTION 1,
SDRVEYDR'S RFPOHT: TOWNSHIP 53 SOUTH, RANGE 41 EAST,
o
1. GROSS LOUD ARM 13,224t SO. HT, MWLI-DADE COUNTY, FLORIDA.
2. MISSURVEY MAR AND REPORT DEPICTS A IROMSCALE: NOT TO SCALEDAR! SURVEY.
(I
3. THE ACCURACY OBTAINED BY FIELD MEASUREMENT METFIODS AND OFFICE CALCUTATONS OF CUMED GEOMETiRC FIGURES MEEK AND MUM TE WANDMOS OF PRACTICE REOMEMEHT
FOR COMMERCIAL NIGH/RISK AREA(UNFAR: 1 FOOT IN 10.000 FEES AS DEFINED IN CHAPTER SJ-17.051, RONIDA ADMINISDATNE CODE.
•
>
yp
4. THE SURVEY MM AND REPORT OR THE COPIES THEREOF ME NOT VALID WTTHOUT THE SIGNATURE AND ME ORIGINN RAISED SEAL OF A FLORIDA UCMSED SURVEYOR AND LIAPPER.
1 F
y
S. TIE SYMBOLS REFLECTED
M THE LEGEND AND ON THE SURVEY HAVE BEEN ENLARGED FOR CHARITY. THE SYMBOLS HAVE BEAU PLOTIIED AT THE GOITER OF THE FOLD LOCATION AND MAY
NOT REPRESENT THE ACIUAL SO E OR SHAPE OF ME FEATURE.
7
8. ME SURVEYOR DID NOT MSPECT THE PROPERTY FOR ENVMNNMEMAL HATARM OR JURISDICTIONAL WERANOS
I()
v,J)
]. ME INFORMATION DEPICTED ON THIS MM REPRESENTS ME RESULTS OF THE SURVEY ON THE GATE INDICATED AND CAN ONLY BE CONSIDERED M INDICATING THE GENERAL CONDITIONS
OUSTING AT MAT TIME.
S. DUE TO THE FREOUMT CHANCES AND INTE]WRETAMONS OF ZONING ORDINARM IT IS ME OWNER'S RESPONSWIL Y W VMIFY ZONING RESBRCIIONS BEFORE ODRSTRUCi
9. ADDITIONS OR DELETIONS TO THIS SURVEY NAP AND REPORT BY OTHER TAN THE SIGNING PARRY OR PARTIES IS .PROHIBITED WRHOUf WRITTEN CONSENT OF THE SIGNING PARTY M
PARTIES.
10, FENCES WERE RECORDED AT THEIR EOSTING PHYSICAL LOCATIONS LE" OWNEf6111P HAS NOT OUR OEMWPEO.
0
QO
11. UNLESS OTHERWISE NOTED. RECORD AND MEASURED DATA ARE IN SUBSTMIML ADREEMEFR. ALL OISTAIICES • ARE M ACCORD WTH TE UNND SLATES STANGMN l9lG FEET.
12. UNITS OF ASPHMT PAVING ME APPRO)—E MO. UNLESS OMERWSE SHOWN. ARE REASONABLY CONSWENT WTTH MISTING ROAD CONgDDIRS.
Z
13. ME STREET RIGHTS -OF -WAY ABUTTING THIS PROPERTY ME PHYSICALLY OPEN UNLESS OTHERWISE NOTED.
14. NO UNDERGROUND AMUiLATIONS OR IMPROVDAENIS HAVE BEEN LOCATED.
15. BEARINGS ARE BASED ON M ASSUMED VALUE OF SOT27'511Y ALONG THE MST RN-YMY HT -OF LINE E OF NORTHWEST 9TST STREET M —1 SHORES IIAGE.
O
18. OWNER INFORHATION SHOWN ON ADMCENT PARCELS WAS RECENTLY GATHERED FROM ME WEBSITE OF THE MMMI-DADE PROPERTY APPAAISM
(�
17. EXCEPT AS SHOWN ON ME RAT OF SURVEY (IF MY), THERE ME NO VISIBLE EASEMENTS OR RIGHTS OF WAY OF WIWOH ME UNDERSIGNED HAS BEEN ADVISED.
Y.1
U
18. ME PROPERTY WAS ACCESS TO AND FROI A DULY DEDICATED AND ACCEPTED PUBLIC STREET OR HIGHWAY.
I9. ME BOUNDARY LINE DIMENSIONS AND DIRECTIONS AS SHOWN ON THE PUT OF SURVEY FORM A WTELAMNLY CLOSED FIGURE
,L,U^
y?w-E
Z S'
20. HORIZONTAL MAIM USED FOR -4 CREATION ID THIS SURVEY LAP: NORM MORNER OFDATUM 83 (HAD 83): FOUND HW CORNEA OF ME SW 1/4 OF THE SW 1/4 OF THE NW 1/4 OF
ME SE 1/4 OF SECTION 1-53S-41E (NAIL MD DISK) AND FOUND WESTERLY CORNERS OF ME SUBJECT PARCEL USED FOR CONTROL.
TA�y F
21. SOURCES USED TO COMPILE SURVEY NAP:
faAMR�Q
W 4
PLAT OF-HOMEDAlE- - P.B. M. PG. 32
1.L
0?�a�
PUT OF N MI SHORES SECTION 6' - P.B. 10, M. 39
Ur S�2
PUT OF 'NMI SHORES MMOR- - P.B. 45, M. 13
(a Z$ a._
22. HORIZONTAL DAMN USED FOR ELEVATION DATA BJIOWH NATIONAL CGEODETIC VERTCA" DAMN 1929 ENS'D a).
LU
N-446 0". 9.65
_.58
ElM 3LOCATION 1: NE 95 ST - M' NORM OF CA
LOCATION 1: NW 85 STREET - 25' SOUTH OF SOUTH EDGE OF PAVING PROIECTED FROM ME WEST LOCATION 2: N MANI AVE - IS' WEST OF PROJECTED WEST EDGE OF PAVEMENT
`z6k�
/ARV °•�
NW
LOCATION 2: 2 AVE - 15' WEST OF C/L LOCATION 3: W' ENE OF FIRE MRML 10' EMT OF A TRAFFIC CONTROL BOX
O
DESCRIPTION: PK NML AND BRASS WASHER IN CONC DECK OF A CATCH BASIN DESCRIPTION: PK NAIL MD BRASS WASHER IN COIC CURB. SY OF A HANDICAP RAMP
y
D f yE
��j
c DH: (AS II— FAYMI JNHT wAQRWiY ,Xm FD W ORO 2W7 £G. ]W6)
' z",^'.,6
ME YEST1> FEET OF ME SOUTH 1/2 IF ME SOVTIRYEST 1/4 OF ME NORTHWEST 1/4 OF ME SOUMMST 1/4 IN SECTION 1. WWNSHIP 53 SOUTH, RANGE 41 EAST, LESS ME NORM
169.25 FEET THEREOF. AND LESS ME WEST 35 FEET AND ME SOUTH W FEET HEREOF, OF THE PUBLIC RECORDS OF WMI-ONE. COUNTY. FLORIDA.
(LJJ
SURVEYOR'S
1 HEREBY CERTIFY, THAT THE PROPERTY AS SHOWN MO DESCRIBED HEREON WAS PREPARED UNDER W SUPFFORM MD TAT MERE NO OBSERVABLE
IN
OAR
UNUSS OTHERWISE SHOWN, ALSO MAT MS BOUNDARY SURVEY MEETS THE STANDARDS FLORIDAOF PRACTICE SET FORM BY ME FLORIN BOARD OF PROFESSIONAL SURVEYORS MD I MPORS IN
SURVEYORS AND NA PEERS
CHAPTER 5J-1].OS FLORIN LOON, PURSUANT TO SECTION 4]2.02], FSTANIES, AND TAT THE SKETCH HEREON S TRUE AND CORRECT ro ME BEST OF MY
\®�
SUBJECT TO
KNOWLEDGE AND BELIEF. SUBJECT W NOTES AND NOTATIONS SHOWN HEREON.
Y
LrtUDIVICI AND OR.WGE CONSULTING ENGNEERS INC. L81012
M
.un•wt/g er� �1 vpsYM�S'^M��A
ip` �
E12'01.
iuliOlA'j�%
`►
►VVV�V�`VV►V*114
VVVVIVVVVVVV♦
1�
C>
R
jjI
E
I
:
+
o
E
j
L=
ZX
I
cu
i�
i
o
(V
i
LL Liu
-- Grade
\\\
Drawing #
6]Scale:
Fence Elevation Merchants Metals Phow:561.478.0059
1 /2" —1'-0" (Typical) 1601 Kill Avenue, Suite B tbaut fa rdnardsmeta�•oom
West Pal Beach, FL 33407
ft"lp► VORICR45C11�
I I I . w1d ■card
,
a ice p to
i I HI
LA
GP
!
i I i I HRi I
i I
-0..
i BD Ma im m M xim m
I GF, o
DR. o Q .X
W
11C o I
HI °
L ,
l PF o
I i
I � I
� �rcidT.
Drawing Gate Details
Scale: 1/2" = 1'-0"
(Typical - Single or Double)
ID
DESCRIPTION
SIZE
REMARKS
®
Board
7111! x 11.3or6'
Tongue and Groove Board
®
Drop Rod
112' 0 Rod
Rod with guide, selftapping #10 x Yr Hex Head saews
®
Gate Fra rm
7W
Fully welded mitered corners
®
Gate Post
6W
0.250 Wall
HI
Hinge
-
Self Closing, selftapping #10 x 31C Hex Head Sam
HR
Horaadal Rai
TxrorMex Me
Ribbed Hortzm1al Rai
®
Latch
45r4'
Self! atdrng, selftapping #10 x 314' Hex Head wawa
®
Line Post
* Y
0.150 Wai
®
Post Cap
Fdto Past
®
Post Footing
TO x 2,r
2,500 psi cornaete
®
Rver
ecei0x
12 1?
Gallantmed steel pipe
O
U CIM1,16l
7F
GENERAL NOTES (Design):
• Design (Decorative barrier at grade) complies with the requirements of the FBC 2017, 6th
Edition & ASCE 7-10, Vult= 122 MPH (Category I, 3 second gust), Exposure D.
• LIMITATIONS: Gate shall be securely locked in place during High Velocity Wind Events > 75
mph. Gate is designed & engineered as a dual leaf but may also be a single leaf using a gate
ost on each side with a latch and air of es. hin
P P 9
• Gate may be installed single or double up to the maximum widths of each leaf.
• The design of this fence is to be used for perimeter enclosure of spaces at grade only and
shall not be used for applications that require safety rails or barriers.
• No changes are allowed without written authorization from the Architect.
• All exposed visible ends shall be provided with caps or covers. •
• All rails shall be notched twice on each side. • • •
• Vertical members shall remain continuous for the full height of each leaf ofWatE: ..
• All gate comers are to be fully welded. ... , ; •
GENERAL NOTES (Installation): .... ..
• POST @ GRADE: Anchored in (2,500 psi) concrete.
GENERAL NOTES (Materials): 00 66'
PVC: •••••• •
• All PVC extrusions shall be made of PVC Resin ASTM 1784 unless noted athenviae. Flevral
Strength = 9,700 psi.
CONCRETE: • • •
• All concrete used for footings or post grout shall reach a compressive strength of 2,500 psi"•
within 7 days. "
SOIL:
• All surrounding soil used for structural installation purposes shall be well compacted by
mechanical means to optimal density and shall be free of deleterious or organic materials.
FASTENERS & ACCESSORIES:
• All fasteners shall be A300 non-magnetic alloy, stainless steel, or other corrosion resistant
material unless specified otherwise.
• Any hinge or latch shall be of structural quality molded polymers or or zinc coated metal and
shall be installed in accordance with manufacturers recommendations.
• Drop rod may be pipe style or pre -manufactured style.
STF��r-•-�; ,
'-x F x .250'
Rail (Any Type)
Rail notch (crimp)
Rail Crimp Notch Detail
Component Schedule and General Notes
Scale: Not to Scale.
� o�
C4
'0 r- �
G O
c
W -0 C
L o <
Ma0,
W Q
E
V
0
j�
V
o
�o
J C
oQ
Y s o
c a O c a) o
Q Z ° U
o 0
°
�L�
o•
P1.0