Loading...
WS-18-3454Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Permit NO.: WS-1 1 -18-3454 Permit Type: Windows/Shutters = orClassijfcation: Window/Door Replacement Permit Status: Approved Issue Date:11/15/2018 I Expiration: 05/14/2019 Location Address Parcel Number 501 NE 106TH ST, Miami Shores, FL 33138 1122310140090 1 Contacts JAMES FIELDS Owner 501 NE 106 ST, MIAMI SHORES, FL 331382045 DVG BUILDERS INC Contractor DANIEL GARCIA 260 PAVER DR, MIAMI SPRINGS, FL 33166 Business: 3055067308 Inspection Requests: Description: INSTALLATION OF IMPACT WINDOWS 15 Valuation: $ 10,000.00 Inspec ion Re 49 TotalSq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $6.00 DBPR Fee $3.75 DCA Fee $2.50 Education Surcharge $2.00 Scanning Fee $9.00 Technology Fee $6.25 Windows/Shutters Fee $200.00 Total: $279.50 Building Department Copy Payments Date Paid Amt Paid Total Fees $279.50 Credit Card 11/15/2018 $279.50 Amount Due: $0.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above named contractor to do the work stated. n It C-PPr Authorized Signature: Own4r / Applicant / Contractor / Agent Date November 15, 2018 Page 2 of 2 4- 4 Miami Shores Village i' Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PE MIT APPLICATION BUILDING ❑ ELECTRIC ❑ ROOFING RECEIVED NOV 15 1(0'18 l (t " FBC 201-4- Master Permit No. VQ S 1(5 3`1S�-k Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: J b e-e t- City: Miami Shores County: Miami Dade Zip: 22 ) 3 r Folio/Parcel#: ! / - jp , ]_ 1 1 r Q -9 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: �!'!/ OWNER: Name (Fee Simple Titleholder): eS Phone#: �3a �e Address:. So , E, /0711- I II__ City: 1�iam �S pk s State: G� ' Zip: Tenant/Lessee Name: Email Phone#: CONTRACTOR: Company Name: "b UI. t p rm2 3-� c — Phone#: S D 3 O$ Address: Z G1'.SO SIlS AV9' City: F!j1P,-a tk State: *r . Zip: 33 1 i0 S Qualifier Name: ��►,.� t i2Gt� Phone#: S O Ci- State Certification or Registration #: �_� l S 107 Z3� Certificate of Competency #: DESIGNER: Architect/Engineer: Address: Phone#: City: State: Zip: Value of Work for this Permit: $ !O k-- Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New []Repair/Repla\lce ❑ Demolition Description of Work: _ '�.-� Sfip,"-o, *n� 'j'C"O r./ S. Tv In clv L---,-j i Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Technology Fee $ Radon Fee $ Training/Education Fee $ DBPR $ Notary $ Double Fee $ Structural Reviews $ (Revised02/24/2014) Bond $ TOTAL FEE NOW DUE $ 46 Bonding company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded otice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit ' ued. In the abseil of such posted notice, the inspection will not be approved and a reinspection fee will be charged. dSignature Signatur OWNER or AGENT CONTRACTOR tl The foregoing instrument was acknowledged before me this The fo*oingiir,4trument was acknowledged before me this 9 day of / VU„ Crn s ('j— 20 1 Y by 1 y y of N 'm )-, C,- - , 20 17 by �Grn� 5 IC— 1 iCA S , who is ersonally known �ct f L J (f --<--', C�,vvh l personally kn to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: I Seal: — Notary Public Stan d Florida +P Nathalie Cepero My Commission GG 252057 a ^ Expires 1211912022 ********** APPROVED BY as me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: 1 I i(. •� Seal: ��+ Notary Public State Of Florida Nathalie Cepero ' My Commission GG 25M7 �lya� Expires 12,19/2022 ****************** * ** ************************************* Plans Examiner Zoning (Revised02/24/2014) Structural Review Clerk 11/15/2018 Property Search Application - Miami -Dade County OFFICE OF THE PR'­R)P­"' 'ERTY APPRAISER r„ Summary Report Property Information Folio: 11-2231-014-0090 Property Address: 501 NE 106 ST Miami Shores, FL 33138-2045 Owner JAMES FIELDS Mailing Address 501 NE 106 ST MIAMI SHORES, FL 33138-2045 PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/2/0 Floors 2 Living Units Actual Area 1 1,916 Sq.Ft Living Area 1,669 Sq.Ft Adjusted Area 1,711 Sq.Ft Lot Size 9,150 Sq.Ft Year Built 1935 Assessment Information Year 2018 2017 2016 Land Value $185,165 $205,739 $172,556 Building Value $107,177 $107,177 $107,177 XF Value $0 $0 $0 Market Value $292,342 $312,916 $279,733 Assessed Value $110,604 $108,330 $106,102 Benefits Information Benefit Type 2018 2017 2016 Save Our Homes Cap Assessment Reduction $181,738 $204,586 $173,631 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption 1 $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description AMD PL MIAMI SHORES SEC 5 PB 10-47 LOT 13 & W1/2 LOT 14 BLK 109 LOT SIZE 75.000 X 122 OR 13392-1851 0887 1 Generated On : 11/15/2018 Taxable Value Information 20181 2017` 2016 County Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $60,604 $58,330 $56,102 School Board Exemption Value 1 $25,000 $25,000 $25,000 Taxable Value 1 $85,604 $83,330 $81,102 City Exemption Value 1 $50,000 $50,000 $50,000 Taxable Value 1 $60,604 $58,330 $56,102 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value $60,604 $58,3301 $56,102 Sales Information Previous Sale Price OR Book -Page Qualification Description 08/01/1987 1 $110,591 13392-1851 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclairner.asp Version: L Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Inspection requirements for: Windows, Doors, Skylights or Fixed Glass (cladding) Permits Upon issuance of permits for the scope of work involving the removal, changing and/or replacement of any type of windows, doors, sidelites, skylights or fixed glass (cladding) the permit holder or qualifier bearing his signature on the permit application shall abide by the requirements of this department and comply with the following statement: Upon obtaining window and/or door permits for the installation of same, it is the responsibility of the permit holder to request window/door framing in -progress inspection, prior to concealment of any horizontal or vertical clip mullion, bucks, shims, etc. Inspector will also verify anchor type, edge distance, embedment and spacing. The purpose for this inspection, is for the verification of conformance with Product Approval (NOA). Iq 11S► Date Print Name Customer Namet )n M e S Ei c i d _�- �cM) c�SEn£r.0 r ,Noaw NCta �SDz%Z.c+y Address: Sit N4i \oL <�(- wIn►�oo,a Nca I.N c)il?.oS ItV.%nn� SttvY�-'��, C� 33k7 S� ;U Phone number: B U I L G) E" S n E-Mail: RESIDENTIAL S COMMERCIAL FJ m o < rotection Type: ❑Accordion ❑Panel Ompact tL %T-Cto't lyp rn_. �o�t3L rr._ Z ITI �_ _ c _- _ 13 (n s NtiC nzF Dj - Ns, D 3�xS'� __ _ _ C34<)�wcM 3 lx-Sb 7x 3S( LU.....-.. 0 __w a- _ __ _ F X _ _3_- - c w, ._ _ ._. • • 7 t • • (3 �L o YesO a 4� - _ �3. X_�0 a��Y3i.0 ••• • `M • ..• • • 37- ooj (3 RAMMS ghGJN1 2100 W 76 Street, Hialeah orida 33016 e o r, P. I # 11955 / 0006024 DESIGN WIND LO IN PSF. FOR 175 MPH 1A f - \ INC. FLORIDA BUILDING CODE, 2017' CE 7-10 WIND CODE K =.85 , ZON Interior & Exterior tones (4&5 - Walls) Posit a Pre sures Exposure C or the 175 mph Wiho Zdne CATEGORY BLD Height (MaximuW ffective Wind Area (or, tary Area) in Square Fee 10 20 60. 1.00 0.95 0.92 0.89 ''0.88 -0.86• 40.4 38.5 37.5 36.7 ,/ - 36.1 ,. ' • 35. X ... 40.8 39.7 38.9 38.3,:.' :.. 37.8 2 44.6 42.6 41.5 40.6' . 40.0 ••• 39.4„• 44.4 43.2 42.3 `,41.7 41. 40 49.4 47.2 45.9 44.9 . ,,'44.2 .. ..' 43.6.% 50 51.8 49.4 48.1 ,47.1 46.4 ; • ; • ; 45.7 • 60 53.7 1 51.2 49.8 48.8 48-1 47. • • • r- f', .. . Interior Zone (4 - Walls) Negative Pressures so Exposure C For the 175 mph Wind, Zone CATEGORY 2 BLDG Height (Maximum) Effective Wind Area (or, Tributary Area) in Square Feet 10 20 30- 40 50 60 -1.10 -1.05 -- "-1.02,/ -0.99 -0.98 -0.96 15 -43.8 -42.0 : ' .: 40:9 -40.2 -39.6 -A 1 20 -46.4 -44(4, ' ,-- -43.3 -42.5 -41.9 -41.4 25 -48.4 -46.4 -45.2 .-47.2 -44.4 -43.8 -43.2 30 -50.5 ' -48.4 - -46.3 -45.6 -45.1 40 -53.6 r 75V4 -50.1 -49.1 -48.4 -47.8 50 -56.2 -53.8 -52.5 -51.5 -50.7 -50.1 60 -58:2 .-- ' , -55.8 -54.4 -53.4 -52.6 1 -52.0 Exterior Zones (5 - Walls) Negative Pressures Exposure C _ For the, 175 mph Wind Zone CATEGORY 2 BLDG Height Maximum Effective Wind Area (or, Tributary Area) in Square Feet 10 20 30 40 50 60 _ - -1.40 -1.29 -1.23 -1.19 -1.15 -1.13 15 - -54.1 -50.4 -48.3 -46.8 -45.6 -44.7 20 - -53.4 -51.1 -49.5 -48.3 -47-3--- 25 -59.8 -55.8 -53.4 -51.7 -50.4 -49.4 0 - . -58.1 -55.7 -53.9 -5 .6 -51.5 40 -66.1 -61.7 -59.1 -57.2 5.8 -54.6 50 -69.3 -64.7 -61.9 -60.0 -58.5 -57.3 60 -71.9 -67.0 -64.2 -62.2 -60.6 -59.4 NOTE: AN 8% REDUCTION OF THE LOADS SHOWN ABOVE MAY BE TAK N FOR FLAI KUUFS. Length of End Zone (a): 10% of least horizontal dimension or .4 h, whichever is smaller' U but not less than 4% of least horizontal dimension or 3 ft. (h = me roof height in j) U -- - - - - - - THESE TABLES ARE NOT TO BE REPRODUCED IN WHOLE OR T V J WITHOUT WRITTEN PERMISSION BY RAMMS ENGINEERING. ALS , THESE TABLES ARE INVALID UNLESS SIGNED WITH BLUE INK AND SEALED B VVV ROBERT MONSOUR. RESIDENCE 501 NE 106T" STREET WINDOW REPLACEMENT PERMIT LAYOUT OPENING SCHEDULE 1-15 OPENINGS (1-15) MRH = <25' WORST CASE SCENARIO ...... . ...... .... . ..... OPENING •••••• •••• ••••• # APPLICABLE NOA WIDTH HEIGHT DESIGN ?;;NSURE . ;. ZONE... 1 18-0213.03 37 50 +44.6/-598 • •: • 5 ""' 2 18-0213.05 74 50 +44.61=59:8 5 ' 3 18-0213.03 37 50 +44.6/-59.8 5 4 18-0213.03 37 50 +44.6/-59.8 5 5 18-0213.03 37 50 +44.6/-59.8 5 6 18-0213.03 37 38 +44.6/-59.8 5 7 18-0213.03 37 50 +44.6/-59.8 5 8 18-0213.03 37 50 +44.6/-59.8 5 9 18-0213.03 37 38 +44.6/-59.8 5 10 18-0213.03 37 50 +44.6/-59.8 5 11 18-0213.03 37 50 +44.6/-59.8 5 12 18-0213.03 37 50 +44.6/-59.8 5 13 18-0213.03 37 38 +44.6/-59.8 5 14 18-0213.03 37 50 +44.6/-59.8 5 15 18-0213.03 37 50 +44.6/-59.8 5 MIAMOOE EW DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE__OF_ACCEPTANCE (NO2 RC Home Showcase, 16115 NW 52°d Ave Miami, FL 33014 MIAMI—DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 T (786) 315-2590 F (786) 315-2599 www.miamidade.Qov/economy ...... .. ... . ..... . This NOA is being issued under the applicable rules and regulations governinjoth" Ise of construction materials. The documentation submitted has been reviewed and accepted by MiaN - jade County RER ; • • • • Product Control Section to be used in Miami -Dade County and other areas whereNLgned by t t Ahthority..... Having Jurisdiction (AHJ). . • . • • • 0000 • • : • • This NOA shall not be valid after the expiration date stated below. The Miami-Da&40ottnty Prodwt Control• • • • • • Section (In Miami -Dade County) and/ or the AHJ (in areas other than Miami-Dadeee8o iV) reserve'the right •, to have this product or material tested for quality assurance purposes. If this product br mat rWMils to"O"o perform in the accepted manner, the manufacturer will incur the expense of such l est ixi* and tti AHJ mays.... immediately revoke, modify, or suspend the use of such product or material within their jurisd'4* � RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. Series "CM100" Outswing Aluminum Casement Window - L.M.I. 11 APPROVAL DOCUMENT: Drawing o. W04-16, titled "CM100 Aluminum Casement Window (L.M.I.)", sheets 1 through 11 of 11, dated 03/01/04, with revision K dated 02/22/18, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Section Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATINGbeMr_ff_rMmmJe_, Large and Small Missile Impact Resistant LABELING: Each unit shall ame or logo, city, state, model/ series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 15-0416.02 and consists of this page 1 and evidence pages E-1, E-2, E-3 and E-4 and Green Sustainable Attribute (G.S.A.) page G-1, as well as approval document mentioned above. The submitted documentation was reviewed by Sifang Zhao, P.E. . 7- / NOA No. 18-0213.03 MIAMI-DADE COUNTY �D aj �!{ f 'l•� I Expiration Date: July 29, 2019 Approval Date: March 29, 2018 Page 1 RC Home Showcase, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 1d-0932.06) 2. Drawing No. W04-16, titled "CM 100 Aluminum Casement Window •(L.M .7? sheets • • • •; • 0/1 1 through 11 of 11, dated 03/01/04, with revision J dated 11/15, pteparPUW;Ll- Farooq Corporation, signed and sealed by Javad Ahmad, P.E. e""' • �' • • sees.. sees B. TESTS sees . sees. 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 • • • • • • • • • • • • • • • 2) Uniform Static Air Pressure Test, Loading pt? FBC, TAS'202-94 " 3) Water Resistance Test, per FBC, TAS 202-5V':': •• j s e sees.. 4) Large Missile Impact Test per FBC, TAS 20J-94e ;"••' e 5) Cyclic Wind Pressure Loading per FBC, TAS,203:94 6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-93 • • e • • along with marked -up drawings and installation diagram of an outswing aluminum casement window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-6439, dated 02/21/11, signed and sealed by Marlin D. Brinson, P.E. (Submitted under NOA No. 11-0922.06) 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Drop Load Test (400 Ft. Lb.), per ANSI Z97.1 along with marked -up drawings and installation diagram of an outswing aluminum Casement window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-5867, dated 05/02/09, signed and sealed by Julio E. Gonzalez, P. E. (Submitted under NOA No. 10-0426.09) 3. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC 2411.3.2.1 and TAS 202-94 along with marked -up drawings and installation diagram of aluminum casement window, prepared by Hurricane Engineering & Testing, Inc., Test Report No. HETI-03-1344, dated 09/12/03, HETI-03-1346, dated 09/16/03, HETI-03-1350, dated 10/14/03 and, all signed and sealed by Rafael E. Droz-Seda, P.E. (Submitted under NOA No. 06-1130.01) Sifang Zhao, P.E. Prod ^�L�E anner NOA No. 18-0213.03 Expiration Date: July 29, 2019 Approval Date: March 29, 2018 E-1 RC Home Showcase, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 4. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked —up drawings and installation diagram of aluminum casement window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No. HETI-03-1848, dated 09/17/03, HETI-03-1856, dated 09/17/03 and HETI-03-1859, dated 01/16/04, all signed and sealed by Rafael E. Droz-Seda, P.E. (Submitted under NOA No. 06-1130.01) • • • • • • C. CALCULATIONS • • • • • """ 1. Anchor verification calculations and structural analysis, conagLvjng with )3C 5t6 • • • • Edition (2014), dated 03/31/15 and 11/090/15, prepared by'Al,-Farrooq Vorpo'ratior�.... ...... .... .. signed and sealed by Javad Ahmad, P.E. • ... 2. Glazing complies with ASTM E1300-09 *Goo . . . . ...... D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resourca mR). • • •' •': E. MATERIAL CERTIFICATIONS 1. NOA No. 14-0916.10 issued to Kuraray America, Inc. for their "Butacite® PVB Glass Interlayer" dated 04/25/15, expiring on 12/11/16. 2. NOA No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on 07/04/18. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 51 Edition (2014), and of no financial interest, dated March 31, 2015, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. 2. Laboratory compliance letters for Test Report No. FTL-6439, dated 02/21/11, issued by Fenestration Testing Laboratory, Inc., signed and sealed by Marlin D. Brinson, P.E. (Submitted under NOA No. 11-0922.06) 3. Laboratory compliance letters for Test Report No. FTL-5867, dated 05/02/09, issued by Fenestration Testing Laboratory, Inc., signed and sealed by Julio E. Gonzalez, P. E. (Submitted under NOA No. 10-0426.09) 4. Laboratory compliance letters for Test Reports No. HETI-03-1346, dated 09/16/03, HETI-03-1848, dated 09/17/03, HETI-03-1856, dated 09/17/03, HETI-03-1859, dated 01/16/04, HETI-03-1350, dated 10/14/03 and HETI-03-1344, dated 09/12/03, issued by Hurricane Engineering & Testing, Inc., all signed and sealed by Rafael E. Droz-Seda, P. E. (Submitted under NOA No. 06-1130.01)yG Sifang Zhao, P.E. NOA No. 18-0213.03 Expiration Date: July 219, 2019 Approval Date: March 29, 2018 E-2 RC Home Showcase, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED G. OTHERS 1. Notice of Acceptance No. 13-1112.10, issued to RC Home Showcase, Inc. for their Series "CM100" Outswing Aluminum Casement Window - L.M.I., approved on 12/26/13 and expiring on 07/29/19. 2. Simulation Performance, Solar Heat Gain Coefficient, Visible Transmittance, & Condensation Resistance Calculation Report on: 1) NFRC 100-2004 "Procedure for Determining Fenestration Product U—Factprs" 2) NFRC 200-2004 "Procedure for Determining Fenestration Product: S"Olar Heat • • • • • Gain Coefficient and Visible Transmittance at Normal Inci Ace" ;...;. •, 3) NFRC 500-2004 "Procedure for Determining Fenestration'Paoduct ('ondensatior!""' Resistance Values" • .... • Using computer simulation in accordance with NFRC: Fran -and EdgVM6delmg:.... THERM 5.x, / WINDOW 5.x NFRC Simulation Manual (Apprupv4 at test f at6), of a • • • RC Aluminum Series "CM100" outswing casement aluminumf nine wifittbW, along'•':' with attached drawings and bill of materials included in Appgngp'x *-A, marked up by National Certified Testing Laboratories, Test Report No. NCT.L-110-12449'Ot,•pageS 01 through 07 of 07, dated 11/12/09, signed by Richard A. McVidcer4II, Simulator, an Steven H. Coble, NFRC Accredited Simulator, Simulator—In—Responsible—ChMe 3. NFRC 102-2004 Thermal Performance Test Report on: 1) NFRC 102-2004 "Test Procedure for Measuring the Steady State Thermal Transmittance of Fenestration Systems" Test report of a series RC Aluminum's Series "CM100" Outswing Aluminum Casement Prime Window with Low E and Argon, along with submittal component drawings, with applicable part numbers, manufacturing and modeling details included in Appendix A, marked -up by National Certified Testing Laboratories, Test Report No. NCTL-110-12450-1, pages 1 through 4 of 4, dated 11/30/09, signed by Christian J. Mitchell, Technician, and Robert H. Zeiders, P. E., Vice —President Engineering & Quality Person —In —Responsible Charge. 4. Recycled Content Determination Report on: Name: Casement Window, CM100 Raw Material: Aluminum Including letter from Fundiciones Industriales S.A. (FISA) dated 03/22/10, certifying that the extruded aluminum products contained 30% recycled scrap material, signed by Henry Kronfle, Vice —President. Sifang Zhao, P.E. NOA N729,2018J Expiration Date: Approval Date: M E-3 RC Home Showcase, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. W04-16, titled "CM100 Aluminum Casement Window (L.M.I.)", sheets 1 through 11 of 11, dated 03/01/04, with revision K dated 02/22/18, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS . 1. None ...... C. CALCULATIONS """ ""% 1. Anchor verification calculations and structural analysis, corgp�jng with F,BC 611....; Edition (2017), dated 02/16/2018, prepared by Al-Farooq Corporation, %1gMd and.... sealed by Javad Ahmad, P.E. • • ; • • ; ; • • • .. .. • • • • • D. QUALITY ASSURANCE .... ...... • . . . . 1. Miami -Dade Department of Regulatory and Economic Resources (RER) ; • • • • • ...... E. MATERIAL CERTIFICATIONS • • • 1. NOA No. 17-1114.14 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 0l/18/18, expiring on 07/08/19. 2. NOA No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 12/28/17, expiring on 07/04/23. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 6th Edition (2017), and of no financial interest, dated February 15, 2018, issued by AI-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. G. OTHERS 1. Notice of Acceptance No. 13-1112.10, issued to RC Home Showcase, Inc. for their Series "CM100" Outswing Aluminum Casement Window - L.M.I., approved on 01/14/16 and expiring on 07/29/19. Sifang Zhao, P.E. Product Control Rv�•-u NOA No. 18-02 33.03 Expiration Date: July 29, 2019 Approval Date: March 29, 2018 E-4 RC Home Showcase, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED GREEN SUSTAINABLE ATTRIBUTES (GSA) SCOPE: This document is solely for the purpose of verification of Sustainable Attributes of construction materials. The documentation submitted has been reviewed by Miami —Dade County Product Control. GA — RECYCLED CONTENT / BIO—BASED MATERIAL / RAPIDLY RENEWABLE MATERIAL Component Name % Recycled % Recycled at Disposal % Bio—based Material % Renewable Material • • • • Content at Manuf. 1. Window Aluminum 30% 100% N/A • • N/ • • 0*0:00 ...... G.8 — U—FACTOR THERMAL TRANSMITTANCE BTU/ HR—FT2—OF ' .. • .' : ""' .9 — SHGC—FACTOR SOLAR HEAT GAIN COEFFICIENT BTU/ HR—FT2 • • • • • • • • • • VT — VISIBLE LIGHT TRANSMITTANCE AT NORMAL INCIDENCE CR— CONDENSATION RESISTANCE • • • ID# Test Re s t#: p Product Number Glazing Components: rs8: U—Pastor G.9: $HGCBase VT .. . CR line Product 000 5/32 CLR 240#2—SS—D—ARG BRZ-1/8-090 PVB-1/8 0.62 0.19 •0 14 17 1. 001 5/32 CLR 240#2—SS—D ARG BRZ-1/8_090 PVB-1/8 0.62 0.19 0.19 17 2. NCTL 002 5/32 CLR 240#2—SS—D_ARG _CLR-1/8 090 PVB 1/8 0.62 0.20 0.25 17 3. 110-12450-1 003 5/32 CLR 240#2—SS—D_ARG_GRN-1/8 090 PVB 1/8 0.62 0.19 0.17 17 4. 004 5/32 CLR 240#2—SS—D ARG GRY-1/8 090 PVB 1/8 0.62 0.19 0.23 17 G.10 — C—FACTOR Component Name 1. Whole Window Legend Abbreviations: Description: SS—D Desiccant —Filled Stainless Steel Spacer 240#2 Cardinal Low E 240 @ #2 Surface Typical ARG 90% Argon PVB 0.090" Poly Vinyl Bu al (PVB) interla er CLR Clear Glass BRZ Bronze Tint Glass GRN Green Tint Glass GRY Gray Tint Glass C—Value 1.94 CONDUCT G-1 Sifang Zhao, P.E. NOA No. 18-0213.03 Expiration Date: July 29, 2019 Approval Date: March 29, 2018 CM100 OPERATING/FIXED Ai TTMTNUM CASEMENT WINDOWS FOR FLANGE FRAME WINDOW CAPACITY SEE SHEETS 2 & 4. FOR FLUSH FRAME WINDOW CAPACITY SEE SHEETS 3 & 4. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). nIMIMM mn INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON-METAWC AND NON -COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME RJTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE LTC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL APPROVAL APPLIES TO SINGLE VENT WINDOWS R-1 OR DUAL VENT WINDOWS USING INTEGRAL pIMPOST. \ / MULLION CAPACITY FOR THIS OPTION ALSO TOP AND BOTTOM COMBINATIONS OF FIXED AND CASEMENT WINDOWS USING STACKING SEE SEPARATE HEAD/SILL WITHOUT MULUON. \ ALSO TO SIDE BY SIDE COMBINATIONS OF CASEMENT/FIXED, CASEMENT/CASEMENT / OR WITH OTHER WINDOW TYPES INMODULES F OF TWO OR MORE WINDOWS \ USING APPROVED MULLIONS. RATING OF FIXED WINDOWS UNDER SEPARATE NOA. THESE WINDOWS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. o c a o � = • • • • • • • SHUTTERS ARE NOT REQUIRED. •• •• ••• • • ••• •• ` �`JT1jTr� Y PRODUCT gREVISED = a 6unai complying the Florida MAR p 2 9n18 ON.".• 1�0213.Q�• ••• ••• .'.4 V • 4plra4n Date 201 • • %O. ATE OF •�fy` drawing no. • • • �'� •. 20 t ' �: W04-16 ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • 37" MAX. 74' MAX. WINDOW WIDTH WINDOW WIDTH 35 3/8' MAX. 35 3/8" MAX. 35 3/8' MAX. VENT WIDTH 30 1/8" MAX. m w FA D.LOPOPG. C I 1 =�- II / II �I II D 1 I K I, I \ 8 5/8" MAX. I HEAD/SILL F^ ^i CORNERS SINGLEVENT WDW. l]' WY MAY VENT WIDTH VENT WIDTH LSE MUNDNS BE USED 30 1/8" MAX. 30 1/8' MAX. D.L OPG. D.L OPG. 6 ` \ I � \ F \\ 8 B I�POST \ \ i I ' I \ .. �d II I� NM<W ' \ p ;gym Ia� N 8 5/8" MAX. I`16' TWO ANCHORS HEAD/SILL AT EACH SIDE OF fOST CORNERS DUA iY ueY 37" MAX. 37' MAX. U U WINDOW WIDTH WINDOW WIDTH 35 3/8" MAX. 35 3/8' MAX. VENT WIDTH VENT WIDTH 30 1/8" MAX. 30 1/8' MAX. D.L OPG. D.L OPG. A / / 6 ` \ I / E - / MUWON 6 \ \ 6 5/8" MAX. 2" 5/8' LOCKING SEE BY SIDE WDWS. ON SHEET 4 O N CORNERS SIDE ? z � TWO ANCHORS � AT EACH SIDE OF MUWON SEE CHART SHEET 4 O Z _ �2 n U� o DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER �T " o • • • • • • • CeRTS•SHJWN � 0SHEET 4. Ail •as coflyyi�•ga Y/th fla ■orl•a • • ��•• ... o 04, • Ito Codes • • • • NOA-No. ie-02i3.0� ^ Expiration Date _07//RAR 0 2 Via ��T • •• �d ••• ••• rol • • ��'•• EOF [yam drowing no. • • • ••• i • i i S'' c►.•''G��� W04-16 FLANGE• AAMI•WI4O!S •• •• •• '��S/OfyA1�`` 112 o111 • • • 'TU 111111`\ sheet ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • 37' MAX. 74' MAX. WINDOW WIDTH WINDOW WIDTH 35 3/8' MAX. 35 3/8' MAX. 35 3/8' MAX. VENT WIDTH ilLO VENT WIDTH 30 1/8' MAX. ¢ FALSE MUNTANS 330 1/8' MAX. mz m w MAY BE USED i D.L OPG. � DA- OPG. Ai \ �� 0 s 1 / \ POST Ic x w d II x I-1. a0 < < x N O N Vf O Y S N I f \ m ,�TI I� _ a I LL 3' 5 3/4' MAX. 8 1/2'MAX. 5 3/4' MAX. IF TWO ANCHORS 37" MAX 37' MAX. U U WINDOW WIDTH WINDOW WIDTH 35 3/8' MAX. 35 3/8' MAX. VENT WIDTH VENT WIDTH 30 1/8' MAX. 30 1/8' MAX. D.L. OPG. D.L. OPG. 81 // `II / ' II II II' II 87 81 M N I /II _ . g3 \ rL \o __II ___ s \ \ 5 3/4' MAX. LOCKING SEE HEAD/SILL HEAD/SILL HEAD/SILL AT EACH SIDE OF IMPOST HEAD/SILL CORNERS SINGL VENT WDW. CORNERS y�. SEE CHART SHEET 4 CORNERS 37' MAX. 37' MAX. WINDOW WIDTH WINDOW WIDTH N1 % rn J �g5 9 K 9 mw i B • �z HI K U / Y � S /Z z x §i a 0N 3 N > \ O n \ / / / / / S / x 4LT\ \ \ N7 M7 \ g 9 5 3/4' MAX. P 8 1/2'MAX. 5 3/4' MAX. r 8 1/2'MAX. HEAD/SILL HEAD/SILL HEAD/SILL HEAD/SILL CORNERS CORNERS SIDE RY SIDE WDWS, ON SHEET 4 j t v N'-n z a TWO ANCHORS E Z AT EACH SIDE OF MULLION SEE CHART SHEET 4 < o E DESIGN LOAD RATINGS FOR THESEINCIDC CHARTS SHOWN ON SHEET 4. O • • • • • • • • • • • • a>,eo�pl yrltlljhs lor�a • • 0 2 Expiration Data oz018 By • • • MlamiiDads P uct Control• • � ®'• FLUSH EMI:: •WINI70j"rS : • • • o • • • ••• • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • ••• • • TO BE AS PER d 9191 � s o e c - I •� OF (yam drawing no. i op'.. A W04-16 j4AL11e�`\ sheet 3 of 11 DESIGN LOAD CAPACITY - PSF SIDE BY SIDE SINGLE VENT WDWS. WINDOW DIMS. GLASS TYPES 'A' A 'E' 1 X 0 MULL 1 X 4 MULL WIDTH (W) HEGHT (H) EXT.(+) INT.(-) EXT.(+) INT.(-) 19-1/B' 24' 26-1/2' 70• 37' 42' 53- 8 38-3/8, 80.0 80.0 $0.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 B0.0 E0.0 80.0 80.0 80.0 80.0 19-1 24' 26-1/2' 30' 37' 42• 48• 53-1/8' �• 80.0 EO.O 80.0 80.0 80.0 90.0 80.0 80-0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 19-1 /8' 24' 26-1/2' 30" 37" 42" 45' 53-1/B" 50-5/8" 80.0 E0.0 80.0 50.0 .0 80.0 0 80.0 80. 80.0 50.0 BOO 80.0 80.0 80.0 1. 80.0 19-1/8" 24" 26-1/2' W. 37 42" 60' 80.0 80.0 ..0 .0 50.0 80. 80.0 80 80.0 O 80.0 80.0 19-1/8' 24" 26-i/2" 3p' 37• 42 Co. 80.0 80.0 80.0 E0.0 80.0 80.0 E0. 80.0 80.0 .0 80.0 19-i/8' 24' 26-1/2' 30' 37' 66, 80.0 80.0 80.0 80.0 80.0 80.0 E0.0 80.0 80.0 80.0 19-1/8' 24' 26-1/2" 30• 37" 72" 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 73.5 80.0 178, 26-1/2' 30' 37• 74-1/4' 80.0 80.0 80.0 80.0 e0.0 80.0 79.2 80.0 66.6 80.0 I DESIGN LOAD CAPACITY - PSF DUAL VENT WINDOWS WINDOW DIMS. GLASS TYPES 'A' k '8' WIDTH (W) HEIGHT (H) EXT.(+) 77• 48• 53-1/8" W. 72" 74' 84' 96" 106-1 4' 38-3/8" 80.0 80.0 00.0 80.0 80.0 80.0 80.0 80.0 37• 53-1/8" 80' 4• 84 ' 96, 106-1/4' 80.0 80.0 80.0 80'0 80.0 80.0 80.0 37" 48' 53-1/8" 60" 72" 74' 84' 60• 80.0 80.0 BOD 80.0 80.0 80.0 80.0 37' 48• 53-1/8' W. 72" 74" 84' 63" 80.0 80.0 80.0 80.0 80.0 80.0 80.0 37' 4g• 53-1/8' Co. 72• 74' 66' 80.0 80.0 80.0 80.0 80.0 80.0 37" 48' 53-1/8' W. 72' 74" 72' 80.0 80.0 60.0 80.0 80.0 80.0 37" 48' 53-1/8' 60' 72' 74' 74-1/4" 80.0 80.0 80.0 80.0 80.0 78.9 DIRECTION OF VENT OPNG. OPTIONAL W W / / t H / / MU 'ION / /I MULUON ITN' ANCHORS EACH SIDE FlXED INDOW OR EMEM WINDOW FO FIX. WOW. RATING S SEPARATE NOA WDW. HEIGHT UPTO N0. OF KEEPERS AT SASH NO- OF I HINGES AT SASH 29-1 4" 2 2 42' 3 2 44-1 4' 3 3 59-1 4" 4 3 74-1/4- 5 3 DESIGN LOAD CAPACITY - PSF SINGLE VENT WINDOWS WINDOW DIMS. GLASS TYPES 'A' h B. WIDTH (W) HEIGHT (H) EX (+) INT.(-) 19-1/E' 24" 26-1/2' 3p• 3�•7,1 48 3-1/8" 48' 80.0 80.0 80.0 80.0 80.0 80.0 80.0 9-1/8• 24' 6-1/2" 37' 48" 53-1/8' 50-5/8 80.0 80.0 80.0 80.0 80.0 80-0 19-1/8" 24' 26-1/2' 30' 37' 42" 60' 80.0 80.0 80.0 80.0 80.0 80.0 19-1/8" 24' 26-1/2' 30' 37• 42' _ 80.0 80.0 80.0 80.0 80.0 80.0 19-1/8" 24" 26-1/2' 30" 37' 66" 80-0 B0.0 80.0 80.0 80.0 19-1/8" 24" 26-1/2' 30' 37• 72" 80.0 80.0 90.0 80.0 80.0 K-1/8" 80.0 • • • • • • • • • • • • PRODI/CTORE AD• • • • • as cdm • A FI•rid• • •• <all•ing • •• NOA-No18-0213.03 Expiration Dat•317/29/2019 MAR p 2 9 NOTE: • ••SY • • ••• Soo 018 GLASS CAPACITIES ON THIS SHEET ARE gtrol• • BASED ON ASTM E1300-09 (3 SEC. GUSTS) • • AND FLORIDA BUILDING COMMISSION FLANGE AND FLUSH.P$AM$. WINDOWS • • : • ; • DECLARATORY STATEMENT OCA05-DEC-219 ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • U � ' 0 �f z 20 O 0 VU N d N it OF F 0 t Oa OR G N g 04H O:mzD N a�7�„ o2, C .� OmQ J aWm€� W = n � I 3 0 n U Z o 0a z N n \ O Z b o 2-.= R V � � Tho NO- OF I NO. OF WDW. HEIGHT KEEPERS HINGES UPTO AT SAS141 AT SASH 42' 2 2 74-1 4' 3 1 3 592 3 1 k ; Q OF �[[/ � drawing o no. /8" HEAT STREWD GLASS .090" Interlayer Troaifol PVB By 'Kurarcy America, Inc.' OR 090' Inte,I.y.r SentryGlas By Kuraray America, Inc.' F1/8" HEAT STREN'D GLASS a: SILICONE E SILICONE ur DOWSIL 795 z m DOWSIL 795 4^4 VENT FIX. LITE G S TYPE `A' 5/32" TEMP. GLASS 1/4' AIR SPACE 1/8' HEAT STREN'D GLASS .090' Interlayer Troaifal _ BR'Kuraray Americo, Inca .090" Interlayer SentryGlaa By 'Kuraray America, Inc' 1/8" HEAT STREN'D GLASS w z m SIUCONE ut DOW51L 795 I DURASEAL SPACER BY IOUANDX' OR 23 CARDINAL XL EDGE SPACER VENT ST. STEEL GLASS TYPE GLAZING OPTIONS NOTE: IN ORDER TO QUALIFY FOR SMALL MISSILE IMPACT RATING EXTERIOR PLY OF GLASS TYPE 'B' MUST BE TEMPERED. FIX. LITE ITEM NO. PART ER QUANTITY DESCRIPTION MATERIAL MANP./SUPLIER/REMARKS 1 C —DOI 2/ WDW FRAME JAMB 6063—T6 — 2 M100-002 2/ WOW FRAME HEAL AND SILL 6063—T6 — 3 CM100-007 AS REDD. FRAME JAMB (FIX.) 6063—T6 FOR FOXED WINDOW 4 CM100-008 AS REDD. HORIZ. IMPOST 6063—T6 FOR FIXED WINDOW CM100-012 AS REQD. JAMB ANCHOR CUP B08J—T6 — 6 CMIOO-013 AS REDD. VENT HINGE 8005—T5 INSTALLED WITH (3) 110 X 3/8" MS 7 CM100-014 AS REDD. I FRAME HINGE 6005—T5 N67ALLED WITH (2) 010 X 3/8" MS 8 CM100-015 AS REDD. FRAME HEAD/SILL (FIX.) 6063—T6 FOR FIXED WINDOW 9 CM100-016 4/ WOW GLAZING BEAD (LAM. GLASS) 6063-1`6 FOR FIXED WINDOW 10 CMIOO-017 4/ WOW GLAZING BEAD (LAM. INS. GLASS) 6063-176 FOR FDXED WINDOW 11 CuiOO-018 4/ WOW SNAP COVER (LAM. GLASS) 6063—T6 IFOR FlXED WINDOW 12 CM100-019 4/ WOW SNAP COVER (LAM. INSUL. GLASS) 6063—Te FOR FIXED WINDOW 13 CM100-032 AS REDO. VERTICAL IMPOST 6D63—T6 — 14 CM100-021 2/ IMPOST ANCHOR CUP FOR VERTICAL IMPOST 6063—T6 — 15 CM100-022 ANCHOR ARM OPERATOR 6063—T6 — 16 AS REQD. SCREENS ALUMINUM OPTIONAL 19 CM100-026 4 VENT STILE 6063—T6 — 20 CMIOO-027 1/ CORNER CORNER LOCK &M3—T6 — 21 V-033 AS REDD. TREMCO TR-5804N SPONGE NEOPRENE — 22 P-049 AS REDD. GLAZING INSERT RIGID PVC MELTPOINT 23 V-055 AS REDD. VINYL FOR LAM. INSUL GLASS — VENT PVC DUROMETER 75±5 SHORE A 24 V-059 AS REOD. VINYL FOR LAM. h LAM. INSUL GLASS (FIX.) PVC MELTPOINT, DUROMETER 75±5 SHORE A 25 AS REDD. 3/16" X 3/8' X 4' LG. SETTING BLOCK EPDM DUROMETER 80±5 SHORE A 26 AS REDD. 1/8' X 1/2" SINGLE FACE TAPE — — 27 P-025 — PLASTIC CAM M h M NYLON — 30 CD25 do CD35 SINGLE ARM OPERATOR ST. STEEL ROTO HARDWARE SYSTEMS 31 — — — — — 32 L305-6645 3 POINT LOCK ASSEMBLY ROTO HARDWARE SYSTEMS 33 CT553 — GUIDE HOUSING — I ATTACHED W/ (3) /8 X 3/4' SMS 34 GS001 — STRIKER ATTACHED W/ (3) /8 X 1/2' SMS 35 10 X 1 2/ CORNER FRAME ASSEMBLY SCREW ST. STEEL PH PHL SMS 6 #10 X 1/2" 2/ CORNER VENT ASSEMBLY SCREWS ST. STEEL FH PHL SMS 3 '10 X 3/4" 4/ CORNER YAPOST ASSEMBLY SCREWS ST. STEEL PH PHL SMS 38 #10 X 3/4" 2/ SIDE IMPOST ASSEMBLY SCREWS ST. STEEL FH PHL SMS 39 100-032 AS REQD. FLUSH ADAPTER HEAD/SILL 6063—T6 — 40 CM —033 AS REDD. FLUSH ADAPTER JAMB I 6063—TB — •• •• • • • • •• i •• i ••i i i i i • • • • • • • • • )�'V .. ... .. . . . .. PRODUCT REVISED — 0 as complying with the Florida = Bullding Cod• NOA-No. 18-0213.03 MAR 0 2_.0 • • • • rt—•T•— • • • 002018 — • • LhpiraUon•Iate07126/2019 • • • • • ••• • • �% Po • my • • • • • • • • 1\I•mi-Dade rf9duct4MtvoI • • • • ////�®NA ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • PjN>_') q _ a or •(V�� drowing o no. W04-16 TYPICAL ANCHORS SEE ELEV. SHEET 2 FOR SPACING 1BY EDGE DIST." -� ,\� W70 BUCK :o O i TYPICAL ANCHORS SEE ELEV. SHEET 2 FOR SPACING U U c rc EDGE N N TYPICAL ANCHORS EDGE SEE ELEV. SHEET 2 D, ST. FOR SPACING s a �^ MIAMI-ME COUNTY APPROVED MULLION h MULLION ANCHORS SEE SEPARATE NOA EDGE DIST. TYPICAL ANCHORS SEE ElEV. SHEET 2 FOR SPACING WEEP SLOT AT EACH END ��N: _.TYPICAL ANCHORS SEE ELEV. SHEET 2 FOR SPACING EDGE DiST7-' TYPICAL ANCHORS SEE ELEV. SHEET 3 WOOD BUCKS AND METAL STRUCTURE NOT BY RC HOME SHOWCASE FOR SPACING MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. EDGE 015T. i y 4 U 1� + WOOD K rvo TYPICAL ANCHORS: SEE ELEV. FOR SPACING q W D UCTURE I 1/4" DNA. ULTRACON BY 'ELCO• (Fa-17T KSI, Fy- KSQ I e a S n a7 o - u= y= INTO 2BY WOOD BUCKS OR WOOD STRUCTURES DO`O d � C4W U 1-1/2" MIN. PEN m D C THRU 1BY BUCKS INTO CONC. OR BLOCKS 0C R1-3/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS 4" MIN. EMBED INTO GROUT -FILLED rcm1-3 0 DIRECTLY INTO CONCRETE OR BLOCKS TMET�2AL 0a 0 d1-3/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) wGTYPICAL ANCHORS MIN. EMBED INTO GROUT -FILLED BLOCKS JAMBS) (� zOFOR SEE EIF/. SHEET 31-3/4" SPACING J m m V STRUCTURE - (GRADE 6 CRS) Q �T Oyi INTO METAL STRUCTURES (HEAD/SILL/JAMBS) 0 EDGE DIST. (3) THREADS MIN. TO EXTEND BEYOND METAL THICKNESS ALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.) STEEL: 1/8" THK. MIN. (Fy = 36 KSI MIN.) c (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) 3 0 n cj 14 SMS OR SELF -DRILLING SCREWS (GRADE 2 CRS) z 3g i INTO MIAMI-DARE COUNTY APPROVED MULLIONS 3 (3) THREADS MIN. TO EXTEND BEYOND METAL THICKNESS w N ALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.) (NO SHIMS) v STEEL: 1/8" THK. MIN. (Fy = 35 KSI MIN.) (NO SHIMS) ¢ V 3 ¢ d. (STEEL IN CONTACT WTRi ALUMINUM TO BE PLATED OR PAINTED) L � CRRICAL EDGE DISTANCE V) M E zvf"p INTO CONCRETE AND BLOCKS = 2-1/2" MIN. ¢ O INTO METAL STRUCTURE = 3/4" MIN. o U o WOOD AT HEAD SILL OR JAMBS SG 0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS Vc = 3000 PSI MIN.- C-90 HOLLOW/FILLED BLOCK AT JAMBS Cm = 2000 PSI MIN. t SEALANTS: ALL FRAME AND VENT CORNERS SEALED o` w ^ g JOINT SEALANT. zs? PRODUCT REVISED - y as comp with the Florida d '3 j, S TYPICAL AN SEE ELEV. SHEET 3 FOR SPACING B e NOA-No. 18-0213.03 3 a� 1 BY 2 Expiration Date 07/29/2019 H WOOD BUCK N c B 1 By Miam�rodue of CC ntr O p 3 d -' 8 o \ I • • rn • • • •\� . .. . ••• ,. . .. ..W. ..toI o > TYPICAL ANCHORS • • • • • • •r • • • T • • • • • �i SEE ELEV. SHEET 2 FOR SPACING EQP1 2ST.• • • • • • • • �� ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • = T92 a a OF .14- drawing no. D�,'JPS W04-16 2BY WOOD TYPICAL ANCHORS EE ELEV. SHEET 3 SPACING E1 WDOD BUCK 1/2 MAx. TYPICAL ANCHORS SEE ELEV.SHEET 2 SPACING O FOR SPACING E 1/4- SHIM 2BY D BUCK �i/4'-SHIM O OR MAX. WOOD CNOR ANCHORS �v SEE EET 2 FOR S ING c Z m 3 F O p „. h ��Nppp 1/4' MAX SHIMS ` 6 CM IBy WOOD BUCKS v U O 13 N 14 � OGNN O O --- - - O O pdaoa 8 C K Z j N m Jz<Jj Q W W f F EXTERIOR D.L OPG. VENT WIDTH = � N Y WINDOW WIDTH o DUAL VENT WINDOWS q w U > i X 3 X 1/8' TYPICAL ANCHORS 1 X 4% 1/8' 3a L 0 N SEE ELEV. SHEET 2 ALUM TUBE FOR SPACING Z fn N M u1 r'7 (6063-T6) 3 J Z TYPICAL ANCHORS 1/4' MAX. O SEE ELEV. FOR SPACING ¢ i O SHIMS p '- E s o EXTERIOR D.L.0". "Y ' WOOD BUCKS v VENT WIDTH p o-' - saa WINDOW WIDTH m o • • . . . . L7\11111j" . • . SIDE DY SIDE WINDOWS • • • • • • • • • • • • •. • • • • • • • . • Sp •'v ENgf o PRODUCT REVISED .e complying with the Florida Building Code • • VS... • 18-,P JV.03 • � � • • ��®. 7 OF ��� drawing ` no. f cplratienhi o� no19 � �• '' �� W04-16 • • iami--Da duct ontro� � • : • • ••• • • • • ••• • • • • • • • • • • • • • • . • • • • • • • • • TYPICAL ANCHORS TYPICAL ANCHORS SEE ELEV. SHEET 3 FOR SPACING EDGE DIST. 1BY, WOOD BUCK. 39 N TYPICAL ANCHORS SEE ELEV. SHEET 3 FOR SPACING 1/2- MAX. SHIMS N1 40 1 G AT FLUSH 1 ADAPTER: ACCESS HOLE Cc ONLM'. I O 1BY tW000 BUCKS x •••� • •PRODUCT RMSED iVi 1 • •� • • • J6 camptntwith the Florida `Y1 e • • • • :pip o d8- 213.03 `•���ajF '.:. • • na • • • Of •F-xplAticw Dst007/29/2019 By I Mlaml-0ad roduct Control —_ CAL ANCS�j11ORS �l SPACINO� 3 • • • +BAR b `i�]j • a ' ce • • • • • • • ?010 �� ••, • •E.0 GIST. • • • • • • • i��Ys� • • • • • ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • a � � OF draw ng o no. I----2028 .562 .062_ � L 1�1.938 I 1.628 .062 TIP. 1.683 � 4 U m 1� Z q F q e 875 .125 ;0:, y7j N .078 1.399 2885 .090 1.885 1.375 .062 � .688 2.625 1.934 •1162 i LL i C 0 N ��,,, o al ^ -0 0 1.906-978-•I II h---1-.500 N n LL 1.738 2 FRAME HEAD/SILL 4 HORw 114POST'--- 1.704 FLUSH ADAPTER HEAD/SILL O M LL Z n �2.562 6.124 683 2.000 02 �• 161 .062 1.708 2.125 .141 .125 1.906 wmi j - L•n$QI• .062 v ' Z ' 2.500 N t FRAME JAMB 13 VERT. IMPOST -1.750 I 2.L-1012 L8174 p- 2.000 .062 .500 2.500 FLUSH ADAPTER JAMB z N N M N _j q ID £O Z 1, �. 2 n U o W .304 1 1111�� ' .062 �.469 �.956 2.125 1 I�2 GLAZING INSERTL 22 RIGID PVC O 2.500---i 1-090 3 FRAME JAMB (FIX.) FRAME HEAD SILL FlX. 8 / (FIX.) 20 CORNER KEY oalo 1.203 - r,170 -f �'1 .734 I 2.750 U S N F 969 907 062 TIP. .050 T. �51jj� YP II .875 .094 1.583 r e 1 �I L-2.187 --I .912 I•� 1.315 -it o E a .1 0. 9O 8•• ••• • • • • • •• GLASS STOP (FlX. LAM. GL) SNAP COVER (FlX. LAM. GL) s JAMB ANCHOR CUP 14 IMPOST ANCHOR CUP •• : tttaHill,7�77 • • • • • • • • • • • .`� pal•.. � � •SF• . S � zso 1.072 .OB TIP .110 oso TW� -( 875 �_ t.561 -{I 562 O .535 • • • • 0.6 • • • �� �. • •. •• ••• •• • • •• PRODUCT REVISED = as complying with the FloAda MAR 0 2 Building Code ,/ 2018 a o .969 .907� 4LM. F-.945-1 .535 Q 1.699 NOA No. 18-0213.03 • • • • • Y-• � N • • • • '� AT OF � •6(/�- • • • Explra0on Date 07/29/2019 • 0 �I �� ���ss •.... dfOwin(J no. W04-16 GLASS STOP (FIX. INSUL GL) SNAP COVER (FIX. LAM. INSUL. GL.) 7 FRAME HINGE 6 VENT HINGE • • • • Miam-DaT�dFUM off• • • • 7t 1,III ,%%% sheet 10 of 11 • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • I 37 Ir� IMPOST CORNER 35 OA �%"u Z mn o�h Qi ?n t1'oo`c o�p got � O G'w � OHo >� 0 a o 0U)Z� N 0 QW.�s �Zh •o Jv0 Q�wmEk' PRODUCT REVISED 92 as complying with the Florida _ Building Cod _� 8 • • • • • • j1pA�lo.. • •18-•0Z13.03 .•� • • • 3`xpiration Q) 07 12019 EOF •�(y, drawing no. • • • •.• off: ram, W04-16 ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • M IAM 1-DADE MIAMI—DADS COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy RC Home Showcase, I c. 16115 NW 52,d Ave Miami, FL 33014 This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami -Dade County and other areas whereallowed by +e•AUhority, • • • • • Having Jurisdiction (AHJ). • This NOA shall not be valid after the expiration date stated below. The Miami-Dadg cggqty PrcpNmt Control, • „• Section (In Miami -Dade County) and/ or the AHJ (in areas other than Miami-Dade.CQaAIy) reserve the right. • to have this product or material tested for quality assurance purposes. if this prodvau or material efails to: perform in the accepted manner, the manufacturer will incur the expense of such t@,A' g and t VAM may • • • • immediately revoke, modify, or suspend the use of such product or material withh? Ikei= jurisdiclimi RER• • • • • reserves the right to revoke this acceptance, if it is determined by Miami-Dade•CoUty ProeIQCf Control• • • •; • Section that this product or material fails to meet the requirements of the applicableNVIVIIDg code. ' This product is approved as described herein, and has been designed to comply with Elie Florida guilding, "' • Code, including the High VelocityHurricane Zone. • • • • • • • • • • • • ' •• • • DESCRIPTION Series "FX100" Aluminum Fixed Window — L.M.I. APPROVAL DOCUMENT: Drawing No. W04- 4 ttt a uminum Fixed Window (L.M.I.)", sheets 1 through 7 of 7, dated 05/29/04, with revision K dated 02/23/18, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING[ Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanentlabel witn the manufactarer s name or logo, city, state, model/ series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.15-0512.24 and consists of this page 1 and evidence pages E-1, E-2, E-3, E-4 and Green Sustainable Attributes (G.S.A.) page G-1, as well as approval document mentioned above. The submitted documentation was reviewed by Sifang Zhao, P.E. NOA No. 18-0213.05 Akib Expiration Date: August 19, 2019 Approval Date: March 22, 2018 Page 1 RC Home Showcase, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA's No. 12-0713.09, 10-0426.07 and 05-0815.01) 2. Drawing No. W04-44 titled "FX100 Aluminum Fixed Window (L.M.I.)", sheets 1 through 7 of 7, dated 05/29/04, with revision J dated 12/09/15, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. . ...... B. TESTS 0• 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 • • • ; • • 0• • • • • • 2) Uniform Static Air Pressure Test, Loading I M•r• U, TAS 202-94 :....: 3 Water Resistance Test per FBC TAS 202-94 • • • • • • • • 2. 3 4) Large Missile Impact Test per FBC, TAS 24L-jU. .... ..:..' 5) Cyclic Wind Pressure Loading per FBC, TASW- 94 • • • • • • • • along with marked -up drawings and installation diagram Dfov4 aluminum fixed •. window, prepared by Fenestration Testing Laboratory, Inc., Test Report NZ...:. • • • • • • FTL-6449, dated 2/29/12, signed and sealed by Marlin D. Brinspn! P,E. * •, ; • • • • (Submitted under NOA No. 12-0713.09) • Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 ..6) Kinetic Energy Drop Load Test (400 Ft. Lb.), per ANSI Z97.1 along with marked -up drawings and installation diagram of an aluminum window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-6043, dated 10/22/09, signed and sealed by Julio E. Gonzalez, P.E. (Submitted under NOA No. 10-0426.07) Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 ..3) Kinetic Energy Drop Load Test (400 Ft. Lb.), per ANSI Z97.1 along with marked -up drawings and installation diagram of an aluminum window, prepared by Fenestration Testing Laboratory, Inc., Test Report No. FTL-5866, dated 10/09/09, signed and sealed by Michael R. Wenzel, P.E. (Submitted under NOA No. 10-0426.07) fixed fixed Z'�_ Sifang Zhao, P.E. Pro t�entry NOA No. 18-0213.05 Expiration Date: August 19, 2019 Approval Date: March 22, 2018 E-1 RC Home Showcase, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS (CONTINUED) 4. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94 2) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of an aluminum fixed window, prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL-4290 dated 08/16/04, FTL-4294 and FTL-4296 dated 10/08/04, all signed and sealed by Edmundo J. Largaespada, P.E. (Submitted under NOA No. 05-0815.01) 5. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 : 0 0 0 : 2) Uniform Static Air Pressure Test, Loading der �$�, TAS 202-94 ••••;• 3) Water Resistance Test, per FBC, TAS 202-94* : • • •: • • ...... . ...... 4) Large Missile Impact Test per FBC, TAS 2Q1.14. 5) Cyclic Wind Pressure Loading per FBC, TASZ63-94 . along with marked -up drawings and installation diagram df• m alutrrinum fixed •; • • window, prepared by Fenestration Testing Laboratory, Inc., Te%T Woorts No:` FTL-4293, dated 10/08/04 and FTL-4295, dated 10/08/04, 4t il"' ed aria s; aled by**::* Edmundo J. Largaespada, P.E. (Submitted under'.NOA;N& 45-08.15.01)..„;. C. CALCULATIONS ' .0. •""' 1. Anchor verification calculations and structural analysis, complying with• �& 5th Edition (2014), dated 04/10/15 and 12/07/15, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. NOA No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on 07/04/18. 2. NOA No. 14-0916.10 issued to Kuraray America, Inc. for their "Butacite® PVB Glass Interlayer" dated 04/25/15, expiring on 12/11/16. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 5" Edition (2014), and of no financial interest, dated April 10, 2015, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. 2. Laboratory compliance letters for Test Report No. FTL-6449, dated 2/29/12, issued by Fenestration Testing Laboratory, Inc., signed and sealed by Marlin D. Brinson, P.E. (Submitted under NOA No. 12-0713.09) 3. Laboratory compliance letters for Test Report No. FTL-6043, dated 10/22/09, issued by Fenestration Testing Laboratory, Inc., signed and sealed by Julio E. Galz, P.E. (Submitted under NOA No.10-0426.07) Sifang Zhao, P.E. Produc NOA No. 18-0213.05 Expiration Date: August 19, 2019 Approval Date: March 22, 2018 E-2 RC Home Showcase, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS (CONTINUED) 4. Laboratory compliance letters for Test Report No. FTL-5866, dated 10/09/09, issued by Fenestration Testing Laboratory, Inc., signed and sealed by Michael R. Wenzel, P.E. (Submitted under previous NOA No. 10-0426.07) 5. Laboratory compliance letters for Test Reports No. FTL-4290 dated 08/16/04, FTL- 4293, FTL-4294, FTL-4295 and FTL-4296 dated 10/08/04, all issued by Fenestration Testing Laboratory, Inc., all signed and sealed by Edmundo J. Largaespada, P.E. (Submitted under NOA No. 05-0815.01) G. OTHERS 1. NOA No. 13-1112.15, issued to RC Home Showcase, Inc. for;their.Series`T%2 00" ...... Aluminum Fixed Window - L.M.I., approved on 12/26/13 and ex'lring on I&JVA19.so .' 2. Simulation Performance, Solar Heat Gain Coefficient, VisipN.-*Tfansmittance, & • • • • • Condensation Resistance Calculation Report on: :....: 1) NFRC 100-2004 "Procedure for Determining Fenestration 13rodaet U—Bd&M8.. .... 2) NFRC 200-2004 "Procedure for Determining Fenestratiolf.11"fgluct Soiap.Heat..:..' Gain Coefficient and Visible Transmittance at Normal Incidence' "• • • • •... 3) NFRC 500-2004 "Procedure for Determining Fenestration:Proclict Condensation •, Resistance Values" • • • • • • Using computer simulation in accordance with NFRC: Frame• laid: Edge Moideling:, • • • • THERM 5.x, / WINDOW 5.x NFRC Simulation Manual (Approved at test.6atel, of a RC Aluminum Series "CM100" outswing casement aluminum prime window, along with attached drawings and bill of materials included in Appendix A, marked —up by National Certified Testing Laboratories, Test Report No. NCTL-110-12451.01, pages 01 through 07 of 07, dated 11/13/09, signed by Richard A. McVicker III, Simulator, and Steven H. Coble, NFRC Accredited Simulator, Simulator —In —Responsible —Charge. 3. NFRC 102-2004 Thermal Performance Test Report on: 1) NFRC 102-2004 "Test Procedure for Measuring the Steady State Thermal Transmittance of Fenestration Systems" Test report of a series RC Aluminum's Series "CM100" Outswing Aluminum Casement Prime Window with Low E and Argon, along with submittal component drawings, with applicable part numbers, manufacturing and modeling details included in Appendix A, marked -up by National Certified Testing Laboratories, Test Report No. NCTL-110-12450-1, pages 1 through 4 of 4, dated 11/30/09, signed by Christian J. Mitchell, Technician, and Robert H. Zeiders, P.E., Vice -President Engineering & Quality Person -In -Responsible Charge. 4. Recycled Content Determination Report on: Name: Casement Window, CM100; Raw Material: Aluminum. Including letter from Fundiciones Industriales S.A. (FISA) dated 03/22/10, certifying that the extruded aluminum products contained 30% recycled scrap material, signed by Henry Kronfle, Vice —President. / Sifangg Zhao, P.E. Pr ro xammer NOA No. 18-0213.05 Expiration Date: August 19, 2019 Approval Date: March 22, 2018 E-3 RC Home Showcase, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. W04-44 titled "FX100 Aluminum Fixed Window (L.M.I.)", sheets 1 through 7 of 7, dated 05/29/04, with revision K dated 02/23/18, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. None C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with;F01�- • 6th Edition (2017), dated 02/15/2018, prepared by Al-Farooq Corpvrat;)n, signed and ••":' sealed by Javad Ahmad, P.E. "'; • • ....; • D. QUALITY ASSURANCE . • • • 1. Miami -Dade Department of Regulatory and Economic Resources iM) • • • • • .. .. .... E. MATERIAL CERTIFICATIONS 000000 ...... 1. NOA No. 17-1114.14 issued to Kuraray America, Inc. for their " Trdsifol® • 0: • Ultraelcar, Clear and Color PVB Glass Interlayers" dated 01:184101, expiring o'h • • • 0 o • .. • • • . 07/08/19. . 0 0 0 0 . 2. NOA No. 17-0808.02 issued to Kuraray America, Inc. for their "SentryGIIR� (Clear and White) Glass Interlayers" dated 12/28/17, expiring on 07/04/23. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 6th Edition (2017), and of no financial interest, dated February 15, 2018, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. G. OTHERS 1. NOA No. 15-0512.24, issued to RC Home Showcase, Inc. for their Series "FX100" Aluminum Fixed Window - L.M.I., approved on 01/14/16 and expiring on 10/19/19. 4� Sifang Zhao, P.E. Pro7March aminer 0213.05 Expiration Da9, 2014 Approval D2, 2018 E-4 RC Home Showcase, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED GREEN SUSTAINABLE ATTRIBUTES SCOPE: This document is solely for the purpose of verification of Sustainable Attributes of construction materials. The documentation submitted has been reviewed by Miami —Dade County Product Control. G.4 —RECYCLED CONTENT / BIO-BASED MATERTAL;/ RAPIDLY RENEWABLE MATERIAL Component Name % Recycled % Recycled at Disposal % Bio—based Material % Renewable Material Content at Manut 1. Window Aluminum 30% 100% N/A N/A .8 — U—FACTOR THERMAL TRANSMITTANCE BTU/ HR—FT2—OF • G,9 — SHGC4ACTOR SOLAR HEAT GAIN COEFFICIENT BTU/ HR-FTZ ' • • • • • • �" =' VT — VISIBLE.LIGHT TRANSMITTANCE AT NORMAL INCIDENCE. �' a s � • CR — CONDENSATION RESISTANCE ' . • : ++.. ID# Test Report#: Product Number Glazing Components: . is �'9' SHGCBase y+T • • • • CR Product 000 5/32CLR —240#2—SS—D ARG BRZ-1/8-090PVB-1/8 .0.48 *0.23 AZg• 16 1. 1 5/32 CLR 240#2—SS—D ARG BRZ-1/8 090 PVB 1/8 01..48 •0.23 .Q.24 16 • 2. NCTL 2 5/32 CLR 240#2—SS—D ARG CLR-1/8 090 PVB 1/8 0.48 0.24 0G 0 16 3. 110-12452-13 3004 5/32 CLR 240#2—SS—D ARG GRN-1/8 090 PVB 1/8 0.48 0.23 0.22 16 4. 5/32 CLR 240#2—SS—D ARG GRY-1/8 090 PVB 1/8 0.48 0.23 0.31 16 Legend Abbreviations: Description: SS—D Desiccant —Filled Stainless Steel Spacer 240#2 Cardinal Low E 240 @ #2 Surface Typical ARG 90% Argon PVB 0.090" Poly Vinyl Bu al (PVB) interlayer CLR Clear Glass BRZ Bronze Tint Glass GRN Green Tint Glass GRY Gray Tint Glass Component Name I C—Value 1. Whole Window 0.95 ifang Zhao, P.E. Product NOA No. 18-0213.05 Expiration Date: August 19, 2019 Approval Date: March 22, 2018 G - 1 w�Wlon1� w� wIDTH� I I W IZz. 3 i 3 g o 3 L J WIND01 1 WIND I I � %s 3 1 I L— —J WINDO, W WIDTH WINDO, W WIDTH I WINDOW W WIDi}Ie.l W I z s W / SI 3 L , D.L. OPG. (SURFACE MAY BE L i. w 4' MAX. CORNER y o CO to FX100 ALUMINUM FIXED WINDOWS TYPICAL ELF A70N TESTED UNITS DESIGN LOAD RATING FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEET 2.1. APPROVAL APPLIES TO SINGLE FIXED WINDOWS, ALSO COMBINATIONS OF FIXED/FIXED OR FIXED WITH OTHER MIAMI-DADE COUNTY APPR'D WINDOWS USING MIAMI-DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO EMIR THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH T E REQUIREMENTS OF THE 2017 (67H EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). NERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS BUILD NG R R 60 1/a' MAX. WINDOW WIDTH �� a 56 1/2' I op D.L. OPG. Z m m 3 Al O F M� a W • I Q IL Z ry 0 IL o IL xx I I m O LL II II O N C II II NNOJ W Z- i/ igg 1 Iii Jzma j QwaOF II II II II I I � J O U ^ c o Z R 1 � w N O U > 81 16' MAXW . � 3 a o- 4 HEAD/SILL Z fn c i a � a � ut r� n m 4 J E a Z L o x Lo._ M O THIS PRODUCT WITH GLASS TYPES 'C', •D' & 'E' COMPLIES WITH REQUIREMENTS OF ANSI Z97.1. TO THE I ST UCTU E. THESE WINDOWS ARE RATED FOR LARGE & SMALL MISSILE IMPACT.1 - ANCHORS SHALL BE CORROSION RESISTANT, SPACED Af •SHlayrpL j1N DETAILS SHUTTERS ARE NOT REQUIRED. d o E WINDOW WINDOW WINDOW WIDTH AND INSTALLED PER MANUF'S INSTRUCTIONS. OR ST4CD EMBED J. LASE • f� - MATERIAL SHALL BE BEYOND WALL DRESSING OR STYICCO. • • • • • \t11111I 11 tt r — F r — — i A LOAD DURATION INCREASE IS USED IN DESIGN OF A%VORS•IRTO N000 ONLY.* • • � o Z o ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC �ANTI AON-OOYRQESSI • • • • • • • ��'• `4F •'• i rc � � I J�� MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT • • • • 0 2 2018 LL = ` 1g � s 3 3 3 COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHAMEET THE PRUDUCi�RBVISED REVISED \ DW2 � 3' 2, REQUIREMENTS OF THE 2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS. 6 �� c ith the Ran&1. THIS PRODUCT APPROVAL IS GENERIC AND DOES 1J T Oh§'&E INFORMATION• • • �,= o FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF- THIS`PRODUCT,•ADEQUAC'fj E)It�p Q OF �` drowing o no. ALLOWABLE LOADS FOR ALTERNATE SHAPES AS SHOWN ABOVE OR SIMILAR CAN BE OF STRUCTURE RECEIVING THIS PRODUCT AND SFfLTNG A$OUND OPlNRJt FOR* 9 '•, P,.•' �� VERIFIED BY INSCRIBING PICTURE WINDOW SHAPE WITHIN SQUARE OR RECTANGLE AS WATER INFILTRATION RESISTANCE ETC. • • • • b ��� S •• ORIO • G`�� W04-44 SHOWN IN DOTTED LINES AND OBTAINING ALLOWABLE LOADS FROM THOSE SHAPES. CONDITIONS NOT SHOWN IN THIS DRAWING ARE VIBE At,LS'ZED SEPAFNITELYI• • hfid� I ��/ S,®NeeeL ����` AND TO BE REVIEWED BY BUILDING OFFICIAL. • • • �Itt11jj11ttt� sheet 1 of 7 • 1/8' HEAT STREN'D GLASS \ .090" Interlayer Trosifol PVB By 'Kuraroy Americo, Inc.' (i F 1/8' HEAT STREWD GLASS C SIUCONE N DOWSIL 795 e g ' 7 70 0 5 I I. 1/4' AIR SPACE 1/8' HEAT STREWD GLASS 1/8' OR 5/32" 090" Interloyer HEAT STREWD GLASS Trosifol PVB By 'Kuraroy America. Inc.' 1/8" HEAT STREWD GLASS CARDINAL XL r SILICONE EDGE SPACER i m DOWSIL 795 i m ST. STEEL 7 a 5A II I.I O I I. I 1I- , gSIUCONE RECT. OR SQUARE FRAM CIRCULAR FRAME RECT. OR SQUARE FRAME CIRCULAR FRAME GLASS TYPE 'A' GLASS TYPE 'B' 1/4' AIR SPACE 1/8" HEAT STREWD GLASS 1/8" HEAT STREWD GLASS 090" Interlayer 1/8" HEAT STREWD GLASS ,090" Interlayer OR SentryGlas 'Kuraroy 5/32" TEMP. GLASS SentryGlas By 'Kuraroy America, Inc.' By America, Inc.' a 1/8' HEAT STREWD GLASS o: 1/8" HEAT STREWD GLASS o. CARDINAL XL Z G SILICONE SILICONE EDGE SPACEF z m DOWSIL 795 z m z m DOWSIL 795 i in ST. STEEL Z 3 � Z y Nm vy�l 7 7 7 5 'IiIIi Ill'I1ii I�� 5A II .II _IIl IIIi 4B oWW SILICONE 9 9 4A 84 RECT. OR SQUARE FRAME CIRCULAR FRAME RECT. OR SQUARE FRAME CIRCULAR FRAME GLASS TYPE 'C' GLASS TYPE `D' 3/16' HEAT STREWD GLASS 090' Interlayer NOTE: Trosifol PVB IN ORDER TO QUALIFY FOR SMALL MISSILE IMPACT RATING By 'Kuraroy Americo, Inc.' EXTERIOR PLY OF GLASS TYPES 'El' & 'D' MUST BE TEMPERED. 3/16" HEAT STREWD GLASS w SILICONE i in SN DOWSIL 795 ••• • • %o g 7A00 ••• • • • • •• • • 100 • • • ca yA • • • • • • • • • o PRODUCT REVISED �mR MAR 0 2BlOdig as complying .Ih the Florida Code 9A 8 • • • • • •• • •"""-4�"4 RECT. OR SQUARE FRAME GLAZING OPTIONS •• • • • �• DalIu3L�Tb•4nV GLASS TYPE 'E' • • • • \� �y•� A9I ':'• CfiNSf'•.. o I DW2 ~ A OF owingv no. v� s •..... �c? . W04-44 �7�is�oiVA1.1�1��� sheet 2 of 7 ••• • • • •• •• DESIGN LOAD CAPACITY -PSF DESIGN LOAD CAPACITY -PSF waanow DtAAs. GLASS TYPBS 'e', '6', 'G' a< ro' GLASS TYPE w>Trpow nlaAs. CLASS TYPBS 'e', '6', 'c' a� 'n' GLASS TYPE •B' WIDTH LENGTH rxr.(+)/INr.(-) Exr.(+)/INr.(-) WIDTH LENGTH EXT.(+)/INr.(-) EXT.(+)/INr.(-) ta^ 19-1/8• 24• 26-1/2" 30• 37• 42• 48" 53-1/8• 60• 72" eD.a so.o 1a' 19-1/8• 24• 26-1/2• 30• 37• 42" 48" 53-1 /8' 92' - eo.o 80.0 80.0 - 80.0 80.0 B0.0 - 80.0 80.0 80.0 - 80.0 80.0 80.0 - 80.0 80.0 80.0 - 80.0 80.0 80.0 - 80.0 80.0 80.0 - 80.0 80.0 80.0 - 77.6 - 80.0 18• 19-1/8• 24" 26-1/2^ 37" 42^ 48• 94• - 80.0 18" 19-1/8• 24' 26-1/2' 30" 37' 42' 53-1/8' 60� 76• 80.0 80.0 - 60.0 B0.0 80.0 - 80.0 60.0 80.0 - 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 - 80.0 80.0 80.0 - 80.0 80.0 0.0 - 18" 19-1/8' 24' 26-1/2• 30• 37` a2' ae• 53-1/8' 60' 78^ - 80.0 - 80.0 - 60.0 - 80.0 - 80.0 - eo.o - so.o - ao.o - 80.0 - 80.0 1g' 19-1/8" 24' 26-i/2• �• 37" 42• aa' 53-1/8' 60' 84" - 80.0 - 80.0 - 80.0 - 80.0 80.0 - 80.0 - 80.0 - so.o - 80.0 - 78.1 18^ 19-1/8• 24• 26-1/2• 30" 37" az' 4a• 53-1/8• 90^ - 80.0 - 80.0 - 80.0 - 80.0 - 80.0 - 80.0 - eo.o - so.o - 80.0 {�v a a 0 Z nn 3 I Oz n4 a Z N i a Z 0 5 0 3� % 0 00 NOTE. WIDTH AND LENGTH DIMEN510 CAN BE O n ORIENTED VERTICALLY OR H 120NTALLY V p m AS SHOWN ABOVE. a pa: C th o O A. 0 4 H O Z. Q W Z LL N u Zy= O uu Q W rn i F O e v 8. e 3 o c Z 3 0 W O X U > Q a O a US (V n Z N M Ez J a 0 =v.=R C) o O m T rc - `u 81a v� c u a ao2$^ •• ••• • • • cs - • • • • • • • • • : • • \V11ttt II l� 21TTA''' • • ••MAR 70592��. ••• ••• • ••• 8� NOTE: • • • • • • • • • Nn OL13.o5 ��®ems A OF /yam\ drawing no. GLASS CA1,0111IES : TMIS CH A:E • • 4 �'•l�S+' ...OA'�C9\�` W04-44 BASED ON ACTM E1,3 0-09 (3� EC.:OUSTS). : • y� *Z I ��i��®®R1A1�`� sheet2.l of 7 • • ••• • •• •• EDGE DIST. _ 16Y OR 2BY WOOD BUCK. -\ d° O C d � a ° ° d ^ EDGE IT TYPICAL ANCHORS SEE ELEV. FOR SPACING a -I SS HOLE i TYPICAL ANCHORS o -SEE ELEV. FOR SPACING I STRUCTURE ;AL ANCHORS ri SEE ELEV. FOR SPACING MIAMI-DADE COUNTY APPROVED MULLION & MULLION ANCHORS SEE SEPARATE NOA TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS HORS SEE a FOR SPACING � a EDG IST. he N o Z q Ng H q o WOOD BUCKS AND METAL STRUCTURE NOT BY RC HOME SHOWCAS f m m MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM o IT I AND TRANSFER THEM TO THE BUILDING STRUCTURE. ISW O `o t� ^ K d W 3 17 N TYPICAL ANCHORS: SEE ELEV. FOR SPACING LL O a I- I ' (F-177 KSI, Fy=15 KSI) n Q > w .l - (F.-i I, y=137 KSI) Q' o M c TYPICAL ANCHORS METAL SEE ELEV. STRUCTURE FOR SPACING EDGE INTO WOOD STRUCTURES 2" MIN. PENETRATION INTO WOOD (HEAD SILL JAMBS) THRU 1BY OR 2BY BUCKS INTO CONC. OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) ar y y O �j Q w IL Z o E s DIST. 1-1/4" MIN. EMBED INTO BLOCKS JAMBS DIRECTLY INTO CON�ER�BLK Q w m i 0 2" MIN. EMBED INTILL/JAMBS) n 2" MIN. EMBED INTCKS (JAMBS) I (GRADE 5 CRS) o 11 -x N INTO METAL STRUCTURES (HEAD/SILL/JAMBS) o O �+ (3) THREADS MIN. TO EXTEND BEYOND METAL THICKNESS Z ?i ALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.) 3 STEEL: 1/8" THK. MIN. (Fy = 36 KSI MIN.) o O (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) X O > MIAMI-DADE COUNTY APPROVED14 SMS OR SELF -DRILLING SCREWS (GRADE 2 CRS) O v a MULLION & MULLION ANCHORS t o O a SEE SEPARATE NOA INTO MIAMI-DADE COUNTY APPROVED MULLIONS in N n hN'o r (3) THREADS MIN. TO EXTEND BEYOND METAL THICKNESS ALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.) (NO SHIMS) a E Z LL STEEL: 1/8" THK. MIN. (Fy = 36 KSI MIN.) (NO SHIMS) _ ,0 (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) O U o J CRITICAL EDGE DISTANCE � � � � � tl INTO CONCRETE AND BLOCKS = 2-1/2" MIN. I MIN. 1BY WOOD BUCK I r ° � ° o TYPICAL ANCHORS SEE ELEV. FOR SPACING 0 WOOD STRUCTURE _ INTO METAL STRUCTURE = 3/4" MIN TYPICAL ANCHORS SEE ELEV. WOOD AT HEAD, SILL OR JAMBS SG a 0.55 MIN. FOR SPACING CONCRETE AT HEAD, SILL OR JAMBS f'e - 3000 PSI MIN. S ° s C-90 HOLLOW/FILLED JAMBS f'm - 2000 PSI MIN. SEALANTS: ALL FRAME AND VENT CORNERS SEALED WITH JOINT SEALANT. d C O O o •• • 3 • • • � • • • • IIIITTAY'' ``\\\\III , • ... MAR02 + RR0tKXr REVISED = No. 70592 v ° r cawoymB with dhe Flaids = ii -: - - 4" TYPItAt • SEE BIEV•JJCHORS• • • *mw No-Qy/.��h7J 4 •• i • • �O ®' '• ATE OF �(/� drawing no. • •FOR dPACING r� DIST* • 0 • • M '� .. omoP..� W04-44 • • • • �• Dade RoAhh:t CaDua1 ��\ sheet 3 of 7 • TYPICAL ANC EDGE DIST. SEE ELEV. FOR SPACIN( 10Y OR 2BYI c a 'NQOD BUCK'd \ I. ;Q a na I 3 A 48 3 11 a N EDGE METAL UCTURE Dlsr[�. r - z Y m w M TYPICAL PNCHORS SEE ELEV. FOR SPACING MIAMI-OADE COUNTY APPROVED MULLION do MULLION ANCHORS SEE SEPARATE NOA TYPICAL ANCHORS SEE ELEV. FOR SPACING ' S ACCESS HOLE I B1 s < N a as " < TYPICAL ANCHORS Z e SEE ELEV. a N FOR SPACING EDGE DIST. 11 s N N TYPICAL ANCHORSEV SEE EL. FOR SPACING I tt n MWAI-DADE COUNTY APPROVED MULLION @ MULLION ANCHORS SEE SEPARATE NOA TYPICAL ANCHORS SEE ELEV. FOR SPACING MAR p 2 2018 • � •, - • • t,illll _ .• •• •• ��`'�� CEO . >• RRODUCTREVISED - T ° • 1IMbtbe - �7 .• � • • •. • BvT ° • • ,• ° iv • tYPICAL ftl"RS • • �d�!- Cwbae JB-0 9.OS • • SEE ELEV. • Dae ®•.. ST E • EOGt OIST. FOR: PACING • • • • :OOMMwdt:rtoAuaCanud • ••• • •• • • • •• •• I � p •�G\�!4\ drowing 44 no. W04— \\\\ sheet 4 of 7 TYPICAL ANCHORS SEE ELEV. FOR SPACING 1/2' SHIM MAX. 11 C TYPICAL ANCHORS SEE ELEV, FOR SPACING 3/B- MAX. SHIMF", C ) TYPICAL ANCHORS WOOD BUCKS O OD MIAMI-DADE COUNTY APPR.D MU ON SEE SEPARATE NOA /14 SMS OR IEKS SCREWS SEE ELEV. FOR SPACING ACCESS HOLE • • • • • • • MARp2N116 . • ♦ • • • • _ PRODUCT REVISED z _ _ _ m1h the Flu de = {} D.L. oPc. EXTERIOR WINDOW WIDTH D: OP: : • • • "w" ' • • • � • ' • • •: • � Y: d '� Sts • ffffll • •• • •• • • • • • • • • ••• • • •• •• .750 .U62 TYP. 2.000 875 II-- 2.125 FRAME JAMB/SILL 1.203 .969 90, 062 TYP. .912 O GLASS STOP (LAM. GLASS) - [.-1 10 .050 TYP. -F 875 L 1.315 �� SNAP COVER (LAM. GLA 1.315 �1 .983 I 865 062 TYP. k-1 182 I� 2.000 F 062 .500 1175 -q .875 FRAME HEAD/SILL/JAMB 1.072 O6 TYP .96� 907 --1.5421- 4A STOP (LAM. INSUL. GLASS) .110-11- .050 TYP. 875 SNAP COVER (LAM. INSUL 1.184 168� 983 J .812 L 48 GLASS STOP (LAM. GLASS) GLASS STOP (LAM. INSUL GLASS) FOR CIRCULAR FRAME FOR CIRCULAR FRAME 734 .094� 1.583 JAMB/SILL ANCHOR CUP .3931 'r -I'r-.380 .500 125 1.788 CORNER LOCK 1.876 .062 674 .500 125J 1.906 11 FLUSH ADAPTER HEAD/SILL .s63 .125 1.804 7.906 ].062 12 FLUSH ADAPTER JAMBS ITEM N0. PART JL- -QUANTITY D,ESGRl4tOlQ'-'-� MATERIAI. MANF./SUPPLIER/REHAB%S 1 Cµ100-007 AS READ. FRAME JAMB/SILL 6063-T6 FOR FIXED WINDOW 2 r' CM100-012 AS READ. JAMB/SILL ANCHOR CUP 6063-76 - /3 CM100-015 AS REDD. FRAME HEAD/SILL/JAMB 6063-T6 - 4 CMIOO-016 4/ WDW GLAZING BEAD (LAM. GLASS) 6063-T6 - 4A CMIOO-017 4/ WDW GLAZING BEAD (LAM. INS. GLASS) 6063-T6 - 48 CM100-029 4/ WDW GLAZING BEAD (LAM. GLASS) 6063-T6 FOR CIRCULAR FRAME 4AB CM100-028 4/ WDW GLAZING BEAD (LAM. INS. GLASS) 6063-T6 FOR CIRCULAR FRAME 5 CM100-018 4/ WDW SNAP COVER (LAM. GLASS) 6063-T6 - 5A CMI00-019 4/ WDW SNAP COVER (LAM. INSUL. GLASS) 6063-T6 - 6 CM100-031 AS READ. CORNER LOCK 6063-T6 - 7 V-059 AS REOD. VINYL FOR 5/16' LAM. k INSUL LAM, GLASS PVC - 7A V-038 AS REOD. VINYL FOR 7/16' LAM. GLASS PVC - 8 AS READ. 3/16' X 3/8' X 4' I.G. SETTING BLOCK EPDM DUROMETER 8035 SHORE A 9 AS READ. 1/8- X 1/2' SINGLE FACE TAPE - - 9A AS READ. 5/16' X 1/2' SINGLE FACE TAPE - - 10 #10 X 1' 2/ CORNER FRAME ASSEMBLY SCREW Sr. STEEL PH PHL. SMS 11 CMlDO-035 AS READ. FLUSH ADAPTER HEAD/SILL 6063-T6 - 12 1 CM100-0341 AS READ. I FLUSH ADAPTER JAMBS 6063-T6 - (2) 110 z 1/2' P.H. SMS L'l f}Io X I/� ' n. ... POINT 'B' SCREW POINT 'B' SCREW 1 3/8' X 1 3/4' z 1/8' THK -�_ WELDED ALUM. PLATE I I 1 1 I \\\ \ j I I I I I I I I I I 1 I I f I I I i 1 \-ITER I CORNERS i i I / I I I CIRCULAR WINDOWS CIRCULAR WINDOWS OPTION 1 OPTION 2 • • FRAMEeCORIICRS! i : : • • • •• • • • • ••• • •• ••• •• •• • • ••• CM1G0-031 CORNER LOCK 1 I II 1 I 1 tt I 1 I I I i (2) #10 z I' P.H. SMS 1 I I POINT 'B' SCREW i � I I 1 � � j I I I � � I I I I I ; , , � i / RECT. OR SQUARE WINDOWS v PRODUCE REVISED .'��v,*bLLICF-AAR 0 2 201a , •; • • • • • M9�1 • • • • • ••• • • •• • ••• •• • • ••••• .NSF '•�*' 70522 VE OF 0 0 � h H W 0 ° O IL N a' O O$y� Oaoa 0.3�I drawing no. W04-44 DESIGN LOAD CAPACITY - PSF SIDE/SIDE OR TOP/BOTTOM WINDOWS WINDOW DIMS. ONE ANCHOR AT EACH SIDE OF MULLION TWO ANCHORS AT EACH SIDE OF MULLION WIDTH (W) LENGTH (L) EXT.(+)/INT.(-) EXT.(+)/INT.(-) 19-1/8" 24" 26-1/2' 37" 42" 48" 53-1/8' 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 19-1/8" 24' 26-1/2" 30" 37" 42" 48" 53-1/8" 48" 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 79.3 80.0 78.1 80.0 0 80.0 19-1/8, 24" 26-1/2" 30" 37' 42" 48' 53-1/8" 50-5/8' 80.0 80.0 80.0 80.0 80.0 80.D 80.0 80.0 75.6 80.0 72.3 50.0 70.4 80.0 70.3 80.0 19-1/8" 24' 26-1/2 30' 37' 42" 60" 80.0 80.0 78.1 80.0 72.6 80.0 66.6 1 80.0 58.6 80.0 54.9 80.0 19-1/8" 24" 26-1/2" 30' 37' 42" 63' 80.0 80.0 73.5 80.0 68.2 80.0 62.4 80.0 54.6 80.0 51.0 80.0 19-1/8" 24' 26-1/2" 30" 37" 66' 80.0 00.0 69.4 80.0 64.3 80.0 58.8 80.0 51.2 89"a 19-1/8" 24' 26-1/2" 30' 37' 72' 75.3 80.0 62.4 80.0 S7.8 80.0 s .8 80.0 45.4 71.6 19-1/8, 24" 26-1/2' 30" 37' 74-1/4" 72.7 80.0 60.2 80.0 55.6 80.0 50.6 77.2 43.6 64.9 (� U TYPICAL ANCHORS ONE OR TWO 1� AT EACH SIDE OF MULLION SEE CHART AT LEFT FOR CAPACITIES Z m^ m W1 W2 f m i Za a Q oy Z m o q _ OSo�m � dN mot 0 t; v O�m m C 0&0 o 0 N O Q WJJ a 7 LL N �ZN_m m a j Qwmf k O - a 0 O C 0 B Z v 3 � N I O X U Q WINDOW ANCHORS SEE 3" SHEET 1 FOR LOCATION AND O v SHEET 3 FOR ANCHOR TYPES (V 10 10" Z i0 7 N Ez�" O h TYPICAL ELEVATIONS oo = 'E n SIDE BY SIDE WINDOWS U o j SIDE BY SIDE APPLIES TO TWO OR MORE WINDOWS O WIDTH (W) = W1 + W2 2 �m e NOTES: 4 o o 1"X3"X 1/8" ~ ALUM TUBE MULLION O E CHART ON THIS SHEEP FOR SIDE BY SIDE CONNECTION z u (6063-T6) OF 1X3 WINDOW MULLION. SEE CHART AT LEFT, FOR OTHER MULLION TYPES TYPICAL ANCHORS 2. FOR FIXED SEE ELEV. D W OW CAPACITY SEE SHEEP 2.1 SEE SEPARATE NOA FOR SPACING 3. FOR OTHER MULUO SEE SEPARATE NOA. 4. USE SMALLER DESIGN LOAD OF 1. 2 OR 3 ABOVE. i6 o oo uigry ••• ••: • • • • • •• 'pc=A o •• ••• •� ••• • • • �. V NSF' - - BRODUCrmwsm .705M tr 000# 08 VIM the Flmidi • • • • • � Code -_ �= o° a o` `u D.L. OPG. L.-L 0 • �••6giefonDMe' O'•• MAR - �drawing EXTERIOR • • • • • • � 2 2018 ••. 71--� WINDOW WIDTHwlNDow WIDTHAW04-44 I I I I11 I01I t 7 of 7 • • • ••• •