Loading...
WS-18-3165Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Permit NO.: WS-10-18-3165 (a^ Permit Type: Windows/Shutters lrR Classlfication: Window/Door Replacement L fljt Permit Status: Approved Issue Dates 11/15/2018 I Expiration: 05/14/2019 Parcel Number 990 NE 97TH ST, Miami Shores, FL 33138 1132060143150 Contacts TRACY YOUNG LE Owner MELO CONSTRUCTION GENERAL Contractor 990 NE 97 ST CONTRACTOR LLC FERNANDO MELO 7405 SW 158 PL, MIAMI, FL 33193 Business: 3052513999 Other:7862273354 Description: NEW IMPACT WINDPWS AND SLIDING DOOR 2 Valuation: $ 10,000.00 Inspection Requests: 305-762-4949 SLIDING DOORS AND 14 WINDPWS TotalSq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $6.00 DBPR Fee $3.90 DCA Fee $2.60 Education Surcharge $2.00 Scanning Fee $9.00 Structural Review ($45) $45.00 Technology Fee $6.50 Windows/Shutters Fee $210.00 Total: $335.00 Payments Date Paid Amt Paid Total Fees $335.00 Credit Card 11/15/2018 $335.00 Amount Due: $0.00 Building Department Copy In considerat' n of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining t e to and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In pt' g t ermit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits ar r it d for EL TRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS A AVI i y that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulatin and zoning. Futhermore, I authorize the above named contractor to do the work stated. Owner / Applicant / Contractor / Agent Date November 15, 2018 Page 2 of 2 101 Miami Shores Village RECEIVED Building Department OCT 16 4n'ia,, 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 I Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 CO BUILDING PERMIT APPLICATION MIBUILDING ❑ ELECTRIC ❑ ROOFING FBC 20 117--1- Master Permit No. N S 1& Z O J' Sub Permit No. ❑ REVISION ❑ EXTENSION [—]RENEWAL PLUMBING ❑ MECHANICAL [:]PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 1610 Occupancy Type: OWNER: Name (Fee Sim Address: cjqO w City: Tenant/Lessee Name: _ Email: Zip_ 01If- "15I Is CL—Is the Building Historically Designated: Yes Load: Construction Type: Ly Flood Zone: BFE: _ -7/11/',r a SIN IIAA / /—, - e#: NO FIFE: CONTRACTOR: Company Name: M-CI6 anftabli i Phone#:a(ZL71 3! L Address: v City: S te: Zi Qualifier Name:f--ce-rimico / O Phone#- i State Certification or Registration #: [ i Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: _ Address: City: State: i Value of Work for this Permit: $ C01660 Square/Linear Footage of Work: Type of Work: ❑ Addition Alteration New ❑ Repair Rep ace u,n Description of Work: a - Sl i dirla /7Cbr5 - �'tD )A07C)S Zip: Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ `JCIO (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature r OVWER o AGENT The foregoing instrument was acknowledged before me this day of _ 20 lc4 by who is personally known to me or who has produced �S%.G as identification and who did take an oath. NOTARY Sign: i Print: GRISEL CARE JAL 4N` V Seal: i° `�: Notary Public - State of Florida c' • . 4 Commission # FF 195256 ,�O� ; ,oa°o' My Comm. Expires Feb 3, 2019 Bonded throw t W yy FA APPROVED BY Signature CONTRACTOR The foregoing instrument was acknowledged before me this day of _ 20 1� by G�'I?GV-ic J who is personally known to Imo_ me or who has produced identification and who did take an oath. NOTARY Sign: ! ' Print: %` iinv n"e, L IS CARBA Seal: ;% * Notary Public - State of Florida • - Commission # FF 195256 % My Comm. Expires Feb 3, 2019 Bonded through National Nnrary Ace„ **************** Plans Examiner Structural Review as *********** Zoning Clerk (Revised02/24/2014) Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Inspection requirements for: Windows, Doors, Skylights or Fixed Glass (cladding) Permits Upon issuance of permits for the scope of work involving the removal, changing and/or replacement of any type of windows, doors, sidelites, skylights or fixed glass (cladding) the permit holder or qualifier bearing his signature on the permit application shall abide by the requirements of this department and comply with the following statement: Upon obtaining window and/or door permits for the installation of same, it is the responsibility of the permit holder to request window/door framing in -progress inspection, prior to concealment of any horizontal or vertical clip mullion, bucks, shims, etc. Inspector will also verify anchor type, edge distance, embedment and spacing. The purpose for this inspection, is for the verification of conformance with Product Approval (NOA). Acknowledgement: Qualifier/O r Sign re Date Print Name 10/9/2018 Property Search Application - Miami -Dade County Ou"FFICE OF w THE' PROPEROrY Summary Report Property Information Folio: 11-3206-014-3150 Property Address: 990 NE 97 ST Miami Shores, FL 33138-2569 Owner TRACY YOUNG LE REM ELIZABETH R SODERHOLM Mailing Address 990 NE 97 ST MIAMI SHORES, FL 33138 USA PA Primary Zone 1100 SGL FAMILY - 2301-2500 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/2/0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 2,611 Sq.Ft Lot Size 11,500 Sq.Ft Year Built 1950 Assessment Information Year 2018 2017 2016 Land Value $310,247 $310,247 $321,563 Building Value $181,726 $181,726 $181,726 XF Value $2,016 $2,028 $2,039 Market Value $493,989 $494,001 $505,328 Assessed Value $493,989 $494,001 $505,328 Benefits Information Benefit Type 2018 2017 2016 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 3 PB 10-37 LOTS 1 & 2 BLK 77 LOT SIZE 100.000 X 115 74R-73102 Generated On : 10/9/2018 Taxable Value Information 2018 2017 2016 ---------------- County Exemption Value $0 $0 $0 Taxable Value $493,9891 $494,0011 $505,328 School Board Exemption Value $0 $0 Taxable Value �$�493,98E9$494,001 $505,328 City Exemption Value $0 $0 $0 Taxable Value $493,989 $494,001 $505,328 Regional Exemption Value $0 $0A$505,328 Taxable Value $493,989 $494,001 Sales Information Prevsous Price O Book - Qualification Description Sale Page a 9 e _ Corrective, tax or QCD; min 04/06/2018 $100 30949-4944 consideration 04/04/2018 $600,000 30929-3608 Qual by exam of deed 06/16/2016 $0 30175-4828 Corrective, tax or QCD; min I consideration 04/01/1974 $80,000 00000-00000 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version Notice to Owner - Workers' Com Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 nsation Insurance Exem Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes, Fla. Star. § 440.05 allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to obtaining a building permit. Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure: An employer in the construction industry who employs one or more part-time or full-time employees, including the owner, must obtain workers' compensation coverage. Corporate officers or members of a limited liability company (LLC) in the construction industry may elect to be exempt if. l . The officer owns at Least 10 percent of the stock of the corporation, or in the case of an LLC, a statement attesting to the tninimum 10 percent ownership; 2. The officer is listed as an officer of the corporation in the records of the Florida Department of State, Division of Corporations; and 3. The corporation is registered and listed as active with the Florida Department of State, Division of Corporations. No more than three corporate officers per corporation or limited liability company members are allowed to be exempt. Construction exemptions are valid for a period of two years or until a voluntary revocation is filed or the exemption is revoked by the Division, Your contractor is requesting a permit under this workers' compensation exemption and has acknowledge that he or she will not use day labor, part-time employees or subcontractors for your project, The contractor has provided an affidavit stating that he or she will be the only person allowed to work on your project. In these circumstances, Miami Shores Village does not require verification of workers' compensation insurance coverage from the contractor's company for day labor, part-time employees or subcontractors. BY SIGNING BELOW YOU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS CONTENTS. Signature: _: - T�� ner State of Florida County of Miami -Dade 1 The foregoing was acknowledge before me this day of / , 20 _ By— who is personally known to me or has produced as identification. Notary Public - State of Florida Commission # FF 195256 My Comm. Expires Feb 3, 2019 i VIC-LO CONST;tUCTION GENERAL CONTRACTOR LLC 10/10/2018 State of County of 12901 SW 133RD CT MIAMI,FL 33186 TEL:305-251-3999 E: Info@melobuiIders.com Before me this day personally pp ersonall a eared /-elzz"eG 4�o who, being duly sworn deposes and says: That he or she will be the only person w rking on the p oject located at: 9qd AJr 7 ���� , Sworn to (or of ' med) and bs�ri�j ed before me this/f%i/clay of •r' 20� by �t��i� Personally know v + Or Produced Identification Type of idwrgi 1catian:Prod �.��" vn'•., GRISEL CARBAJAL Notary Public - State of Florida Commission # FF 195256 My Comm. Expires Feb 3. 2019 Bonded through Natinnai NrMavGbca, t, type or stamp name of 1 r M IAM I•DADE P MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 r, DiJ'kXTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/economy ECO Windows Systems, LLC 9114 N. W. 106' Street, Medley, FL 33178 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately re"e„jpodify, or suspend the use of such product or material within their jurisdiction. RER reservers• the right to revoke'tht? • acceptance, if it is determined by Miami -Dade County Product Control Section that thii.prp&ct or%ia.tonal fails td. meet the requirements of the applicable building code. • • • •.. This product is approved as described herein, and has been designed to comply with the P4orida Buil-d njeCode, ; • • • •; including the High Velocity Hurricane Zone. "'' DESCRIPTION: Series "700" Aluminum Sliding Glass Door w/ Reinforcements-I.DI, 0• • APPROVAL DOCUMENT: Drawing No. W13-49 REV D, titled "Series- 700 Alum $L•lP' filass Door (L.M.I.)",.' sheets 1 through 12 of 12, prepared by Al-Farooq Corporation, dated 09/27/ 13 and last-evised on J4";% 2018-, • • • : • signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Con;pj 4(rvisiori stamp with.'tjw. .; Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Secttb0.• • - MISSILE IMPACT RATING: Large and Small Missile Impact Resistant Limitations: 1. See Design Pressures Vs Reinforcing, glass types and anchor capacity charts in sheet 5. Exterior (positive) design pressures are limited to +70 PSF w / 2-3/4" sill riser and +47.0 PSF w/ 2" sill riser. Lower design Pressure from charts applies to entire system. 2. See approved configurations in sheets 1 thru 4. The max frame are of alternate sizes not to exceed tested frame area per FBC requirements. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and following statement: "Miami -Dade County Product Control Approved", noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises #15-0612.05 consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda, P.E. ` NOA No. 18-0129.13 Expiration Date: March 20, 2019 Approval Date: March 22, 2018 Page 1 ECO Windows Systems, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1 Evidence submitted under previous approvals A. DRAWINGS 1. Manufacturer's die drawings and sections (see below) 2. Drawing No. W13-49 REV C, titled "Series- 700 Alum SLD. Glass Door (L.M.I.)", sheets 1 through 12 of 12, prepared by Al-Farooq Corporation, dated 09/27/13 and last revised on DEC 02, 2015, signed and sealed by Javad Ahmad, P.E. B. TESTS (Submitted under file #13-0912.02) 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 2Q3-94 :900:0 6) Forced Entry Test, per FBC 2411 3.2.1, TAS•207,94 0 • • along with marked -up drawings and installation diagrams of Alum sltdh g Glass doors, ....:. prepared by Fenestration Testing Lab, Inc., Test Report No. FTL-748*datded 09/13y2013 a �i•••; last revised on 02/ 10/2014, signed and sealed by Marlin D. Brinson, P. o *: • : • • • • • • • Note: The above referenced test report has an addendum letter dated DEB• 10, 20 14, issued by . • • Fenestration Testing Lab, Inc., signed by Ms. Iliana Sanchez, test rejrrAuthor. • • : • • •... C. CALCULATIONS 0 60 06:0• 1. Anchor verification calculations and structural analysis, complyi;4v�nth FBC 2014 (5t; ••; Edition), prepared by Al Farooq Corporation, dated 06/10/15 and last revisetl r ]PEC 02, 2015, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies w/ ASTME-1300-02, -04 & -09. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.10 issued to Kuraray America, Inc. (Former E.I. DuPont DeNemours & Co., Inc.) for the "Kuraray Butacite ® PVB interlayer", expiring on 12/11/16. 2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. (Former E.I. DuPont DeNemours & Co., Inc.) for the "Sentry Glass ® (Clear and White) Glass Interlayers", expiring on 07/04/17. F. STATEMENTS 1. Statement letter of conformance to FBC 2014(5" Edition) and letter of no financial interest, prepared by Al Farooq Corporation, dated 06/10/15, signed and sealed by Javad Ahmad, P.E. 2. Lab compliance as part of the above referenced test report. G. OTHER 1. Test proposal, dated 03/25/13 approved by Jaime D. Gascon,,P.E. Is aq I. Chanda, P.E. Product Control Examiner NOA No. 18-0129.13 Expiration Date: March 20, 2019 Approval Date: March 22, 2018 E-1 ECO Windows Systems, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. New Evidence submitted. A. DRAWINGS 1. Drawing No. W13-49 REV D, titled "Series- 700 Alum SLD. Glass Door (L.M.I.)", sheets 1 through 12 of 12, prepared by Al-Farooq Corporation, dated 09/27/13 and last revised on JAN 23, 2018, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. None. C. CALCULATIONS 1 None. D. QUALITY ASSURANCE ; • • • • 1. Miami Dade Department of Regulatory and Economic Resources TVZ1; P. ., • 069VO .... • • ...... E. MATERIAL CERTIFICATIONS • • •' • • • 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America., 11it;'4f6rnWtII. DuPont DeNemours & Co., Inc.) for "Trosifol: Ultra clear, clear,4.*�q%or PVB lass ••;•�• interlayer" (former "Kuraray Butacite PVB Interlayer)", expiring oh 09/08/ t E .00. • • • • • 2. Notice of Acceptance No. 17-0808.02 issued to Kuraray Americ4,•hio.;(former E.I. • • DuPont DeNemours & Co., Inc.) for the "Kuarary Sentry Glass 9 Intlerlayri •.%xpiring..:. on 07/4/23. F. STATEMENTS 1. Statement letter of conformance to FBC 2017(6th edition) prepared by Al-Farooq Corporation, dated JAN 23, 2018, signed and sealed by Javad Ahmad, P.E. G. OTHER 1. This NOA revises NOA # 15-0612.05, expiring 03/20/2019. le'L, Ishaq I. Chanda, P.E. Product Control Examiner NOA No. 18-0129.13 Expiration Date: March 20, 2019 Approval Date: March 22, 2018 E-2 MIAMI•DADE M-IAMI-DADE COUNTY, FLORIDA • PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Eco Window Systems, LLC 8502 Nam'80" Street Medley, Fl. 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). • • • • • This NOA shall not be valid after the expiration date stated below. The MiaNwI)acle Col-"W, Product . • Control Section (In. Miami -Dade County) and/ or the AHJ (in areas other than Miami :Nude Cotim5i) reser�o&..:. the right to have this product or material tested for quality assurance purposes. IIIA S'product crr materi;j • • • fails to perform in the accepted manner, the manufacturer will incur the expense of •sub$ testing avAthe AIHJ • may immediately revoke, modify, or suspend the use of such product or material wit�iin their�urisdiction :••. RER reserves the right to revoke this acceptance, if it is determined by Miaq-1-!-Vgde CdtLrlty f rodu"• • • Control Section that this product or material fails to meet the requirements of the applicable building code. . • This product is approved as described herein,, and has been designed to comply wA tie Florida$uildit#g •.:. ...... Code, including -the High Ve ocity Hurricane Zone. 000000 DESCRIPTION. Series "ECO-Guard Clipped" Aluminum Tube Mullion - L.M.I. • • • • • • APPROVAL DOCUMENT: Drawing No. -M14-01 Rev. A, Series titled '`Aluminum Tube Mullion", sheets 1 through 9 of 9, dated 05/19/14 with the latest revision dated 11/15/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P. E., bearing the Miami Dade County Product Control Section Revision stamp with the Notice of Acceptance number and Expiration date by the Miami -Dade County Product Control Section_ MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERIVIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use; and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any, prod -act, for sales, advertisimgor any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded. by the words Miami -Dade County_ , Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 14-0529.16 consists of this page 1 and evidence pages E-I, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Jorge M. Plaseneia, P. E. NOA No. 17-121814 MIAM!�ADE COUiJiY Expiration Rate: October 23. 2019 Approval Date: February 22, 2018 �oL/lt 1� Page 1 Eco Window Systems, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 14-0529.16 A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. M14--01, Series titled "Aluminum Tube Mullion", sheets 01 through 09 of 09, dated 05/19/14 with the latest revision dated 05/23/14, prepared by Al— Farooq Corporation, signed and sealed by Javad Ahmad, P. E. B. TESTS • 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 . • . • • • • ; • 2) Uniform Static Air Pressure Test, Loading• ;FBC, �Q, —02-94 • ...... 3) Water Resistance Test, per FBC, TAS 202•4-1+.. along with marked —up drawings and installation diagram 0� t,clipp:4,, �d-vminurri • • mullion at -fixed windows, prepared by Hurricane EngineermA X •Testine� •Inc., T6s*E 0 0 . Report No. HETI-08-2192A, dated 01 /15/09, signed and sea00000 ms, by CarNoo f . FoW. • • • P. E. . 2. 00 Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-9'4 000000 • • • • • • 2) Cyclic Wind Pressure Loading per FBC, •A�-?Q3-94.. 0 •..... . along with marked —up drawings and installation diagram of a clippW. Wtuni um mullion at a fixed window/ a single hung window, prepared by Hurricane Engineering & Testing, Inc., Test Reports No.'s HETI48-2192B and HETI48-2166C, both dated 01/15/09, signed and sealed by Candido F. Font, P. E. 4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test; Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 .along with marked —up drawings and installation diagtr3m of a clipped aluminum mullion single hung window, prepared by Hurricane Engineering & Testing, Inc_, Test Report No..HETI--08-2166A, dated 01/15/09, signed and sealed by Candido F. Font, P. E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis. -complying with FBC-2010 and FBC 51` Edition (2-014), prepared by AI—Farooq Corporation, dated 05105114, signed and sealed by Javad Ahmad, P. E. D. QUALITY ASSURANCE 1. Miami —Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. E-1 Jorge M. Piasencia, P. E. P Control Unit Supervisor NOA No. 17-1218.14 Expiration Date: October 23, 2019 Approval Date: February 22, 2018 Eco Window Systems, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of no financial interest, conformance to and complying with FBC-2010 and FBC 5th Edition (2014), issued by Al—Farooq Corporation, dated 05/23/14, signed and sealed by Javad Ahmad, P. E. 2. Department of State Certification of Eco Window Systems, LLC as a limited liability company, active and organized under the laws of the State of Florida, dated 03/21/13 and signed by Kurt S. Browning, Secretary of State. 3. Laboratory compliance letter for Test Reports 1).'r'. BE, 7I-08-2192A' •; • HETI48 219213 HETI-08-2166A and HETIA8-21;.: all• •: * t tied bX Hurricane Engineering & Testing, inc., dated 01/15/09,..sid and .sealed .by Candido F. Font, P. E. 0 • • • • • • : • • 0 •: 4. Proposal No. 08-0236 issued by the Product Control, datt8' D6/04/08, signed *13 j7 ...... .... ..... Manuel Perez P. E. • G. OTHERS • • • • • • 1. None. • ...... 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. M14-01 Rev. A, Series titled "Aluminum Tube Mullion", sheets 1 through 9 of 9, dated 05/19/14 with the latest revision dated 11/15/17, prepared by Al— Farooq Corporation, signed and sealed by Javad Ahmad, P. E. B. TESTS 1. None. C. CALCULATIONS 1. Structural analysis, complying with FBC 6th Edition (2017), prepared by Al—Farooq Corporation, dated 11/30/17, signed and sealed by Javad Ahmad, P. E. D. QUALITY ASSURANCE 1. Miami —Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. E-2 urge NI. Plasencia, P. E. Prod et Control Unit Supervisor NOA No. 17-1218.14 Expiration Date: October 23, 2019 Approval Date: FebruaryZ2, 2018 Eco Window Svstems, LLC • NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance to FBC 6th Edition (2017) and of no financial interest, issued by Al—Farooq Corporation, dated 11/14/17, signed and sealed by Javad Ahmad, P. E_ G. OTHERS 1. This NOA revises NOA #14-0529.16, expiring on 10/23/19. f • • • •••••• 0*000 •••••• •••• ••••• • • • • • •• •• •• • •••••• • •••••• • • • • • • •••••• •••••• •• • •• • • • 00 Jorge M. Plasencia, P. E. Proiluct Control Unit Supervisor NOA No. 17-1218.14 Expiration Date: October 23, 2019 Approval Date: February 22, 2018 E-3 M IAM I-DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Eco Window Systems, LLC 8502 NW 80 Street Medley, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Mianri-Dade C.ourixy Pro4l" Control • Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade CN") resezir ZW right go to have this product or material tested for quality assurance purposes. If this prMi MC flr material fails tq perform in the accepted manner, the manufacturer will incur the expense of such testing and:hq,& ma�' •; ...q immediately revoke, modify, or suspend the use of such product or material within th i� jurisdiction. RER... reserves the right to revoke this acceptance, if it is determined by Miami-Dada044rlty PraduofContrdl':•- Section that this product or material fails to meet the requirements of the applicablabuilding code.. • This product is approved as described herein, and has been designed to comply ;vith�t�re Florida.Buildiq& : Code, including the High Velocity Hurricane Zone. . 000 : 0 0 •" DESCRIPTION: Series "Eco-Guard 60" Aluminum Horizontal Rolling Window — L.M.Ie • APPROVAL DOCUMENT: Drawing No. W14-11, titled "Eco-Guard Series-60 Alum Horiz. Rolling Wdw. (L.M.I.)", sheets 1 through 5 of 5, dated 03/28/14, with revision B dated 10/19/17, prepared by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 14-0403.09 and consists of this page 1 and evidence page E-I and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Sifang Zhao, P.E. ' NOA No. 17-1102.22 p�pS2E11� Expiration Date: June 19, 2019 Approval Date: January 11, 2018 Page 1 Eco Window Systems, LLC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA No. 14-0403.09 A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No W14-11, titled "Eco-Guard Series-60 Alum. Horiz. Rolling Wdw. (L.M.I.)", sheets 1 through 5 of 5, dated 03/28/14, with revision A dated 05/23/14, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 0 • 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 : • •• • 00000 2) Uniform Static Air Pressure Test, Loading p;j*FBC, TAS20?-9 3) Water Resistance Test, per FBC, TAS 202-94.:.. • 4) Large Missile Impact Test per FBC, TAS 2Q>-940 5) Cyclic Wind Pressure Loading per FBC, TA9703-94 • • •" .0 . along with marked —up drawings and installation diagram of an Ft,.p. ward. Wit$ 60 aluminum horizontal rolling window, prepared by Fenestration: gsting Laboratory, Inc., Test Report No. FTL-7634, dated 12/09/14, signed and staled �y MarliD. Brinson, P.E. • • . C. CALCULATIONS • • • 1. Anchor verification calculations and structural analysis, complying with FBC 511 Edition (2014), dated 03/19/14, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) 4 ' ...... ...... .' ....4 . • E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 13-0129.27 issued to E.I. DuPont DeNemours & Co., Inc. for their "DuPont Butacite® PVB Interlayer" dated 04/11/13, expiring on 12/11/16. 2. Notice of Acceptance No. 12-1231.09 issued to Eastman Chemical Company (MA) for their "Saflex HP Clear or Color Glass Interlayers" dated 03/28/13, expiring on 04/14/18. F. STATEMENTS 1. Statement letter of conformance, complying with FBC-5t4 Edition (2014), and of no financial interest, dated March 31, 2014, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. G. OTHER 1. None. E - 1 S;41y 7,4" Sifang Zhao, P.E. Product Control Examiner NOA No. 17-1102.22 Expiration Date: June 19, 2019 Approval Date: January 11, 2018 Eco Window Systems, LLC. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No W14-11, titled "Eco-Guard Series-60 Alum. Horiz. Rolling Wdw. (L.M.I.)", sheets 1 through 5 of 5, dated 03/28/14, with revision B dated 10/19/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS 1. None. • C. CALCULATIONS • • • • • 1. None. ...:.. •••••• D. QUALITY ASSURANCE • • • • • 1. Miami -Dade Department of Regulatory and Economic ResourcKMR) , • •; • • ..:.. • E. MATERIAL CERTIFICATIONS • 1. Notice of Acceptance No. 17-0712.05 issued to Eastman Ch*nignl Cord0fM}'(MA)•••" for their "Sa#lex Clear and Color Glass Interlayers" dated QM7/17, ex'jjirj r% on :"• •, 05/21 /21. of 2. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Interlayers" dated 01/19/17, expiring on 07/08/19. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 5th Edition (2014), with FBC 6th Edition (2017), and of no financial interest, dated October 12, 2017, issued by Al- Farooq Corporation, signed and sealed by Javad Ahmad, P.E. G. OTHER 1. Notice of Acceptance No. 14-0910.09, issued to Eco Window Systems, LLC for their Series "Eco-Guard 60" Aluminum Horizontal Rolling Window -L.M.I., approved on 06/19/14 and expiring on 06/19/19. Sifang Zhao, P.E. Product Control Examiner NOA No. 17-1102.22 Expiration Date: June 19, 2019 Approval Date: January 11, 2018 E-2 9 MIAMI•DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy ECO Windows Systems, LLC 9114 N. W. 106' Street, Medley, FL 33178 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to.perfortp•i" the accutrA • manner, the manufacturer will incur the expense of such testing and the AHJ may imluQdialely revokeq modify, or e � t suspend the use of such product or material within their jurisdiction. PERA resefrke rig4 to•revoka tk" • acceptance, if it is determined by Miami -Dade County Product Control Section that thfSp;Muct or mAterial faf1,s•tA6; meet the requirements of the applicable building code. ."". :...:. ' This product is approved as described herein, and has been designed to comply with the f f orlda Buitdin4Code, • including the High Velocity Hurricane Zone. • .. .. .. . ...... DESCRIPTION: Series 600 Aluminum Outswing Doors-L.M.I. • • • • • • • • APPROVAL DOCUMENT: Drawing No. W12-08 Rev E, titled "Series 600•Alum Optswing Entpwv- Door , • • • •, (L.M.I.)", sheets 1 through 9 of 9 (inclusive 7.1), prepared by AL-Farooq Corporation, 8ate'd 02/13/12.and last :" revised on MAR 15, 2018, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade Count _F;educt Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant Limitation: 1. See Single or Double Door Design Pressure (DP) ratings in sheet 2. See Single or Double Door DP ratings with sidelites (w/wo Reinforcement) and Standalone Single sidelite rating in sheet 3. The max door leaf width shall not to exceed 37". See locking options 1 & 2 in sheet 7_1. 2. Laminated glass types G 1 and G2 are limited to Kurarary's .090" Trofosil PVB and glass type G3 is limited to Insulated laminated glass w/ Eastman Chemical's .090" Saflex interlayer. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and following statement: "Miami -Dade County Product Control Approved", noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #17-1218.15 and consists of this page 1 and evidence pages E-1 & E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda, P.E. NOA No. 18-0319.13 MIAMi oa�E CouNTY Expiration Date: March 20, 2019 Approval Date: May 10, 2018 Page 1 . r ECO Windows Systems, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. Evidence submitted under previous approvals A. DRAWINGS 1. Manufacturer's die drawings and sections (see below) 2. Drawing No. W12-08 Rev C, titled "Series 600 Alum Outswing Entrance Door (L.M.I.)", sheets 1 through 9 of 9 (inclusive 7.1), prepared by AL-Farooq Corporation, dated 02/13/12 and last revised on SEP 04, 2015, signed and sealed by Javad Ahmad, P.E. B. TESTS (submitted under file #12-0402.03) 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 • 4) Large Missile Impact Test per FBC, TAS 201-94 . :"'•' ...... 5) Cyclic Wind Pressure Loading per FBC, TAS 203-91 . • • • •. •, 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202 V4:0 • • • •' "•' •' ...... . along with marked -up drawings and installation diagram of an aluminum Outsv4ng Frenchrdoor, ; • • • • ; prepared by Hurricane Engineering & Testing, Inc., Test Report No. 000000 0.0. HETI-12-3357, HETI-12-3358, HETI-12-4003, HETI-12-4003 and HETT X9027dtW 03/16' •' .. • 2' 26/12 all signed and sealed by Rafael E. Droz-Seda P. E. • • • • • • • • • • • • • Note: The above referenced test reports have been revised by an addendum 7etttr::lated.June 29, 2012,:. issued by Hurricane Engineering & Testing, Inc., signed and sealed by Rafael $? proz-geaa,•P. E.: • C. CALCULATIONS • • • • 1. Anchor verification calculations and structural analysis, complying with FBC-2014(5th Edition), prepared by Al Farooq Corporation, dated June 02, 2015, signed and sealed by Javad Ahmad, P.E. 2. Glazing complies w/ ASTME-1300-02, -04 & -09. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 11-0624.01 issued to Kuraray America, Inc. (Former E.I. DuPont DeNemours & Co., Inc. for the `Butacite ® PVB interlayer", expiring on 12/11/16. 2. Notice of Acceptance No. 12-1231.10 issued to Eastman Chemical Company (MA) (former Solutia, Inc.) for the "Saflex: Saflex Clear & Color glass interlayer", expiring on 05/21/16. 3. XL Edge seal System 201 SS spacer by Cardinal IG. F. STATEMENTS 1. Statement letter of conformance to FBC 2014 (5t' Edition) and letter of no financial interest, prepared by Al Farooq Corporation, dated 06/02/15, signed and sealed by Javad Ahmad, P.E. 2. Addendum letter dated June 29, 2012, issued by Hurricane Engineering & Testing, Inc., signed and sealed by Rafael E. Droz-Seda, P. E. 3. Lab compliance as part of the above referenced test report. G. OTHER 1. This NOA revises NOA #15-0603.13, expiring 03/20/19. 2. Test proposal, dated 10/14/11 and 02-21-12 approved by PERA. Is aq I. Chanda, P.E. Product Control Examiner NOA No. 18-0319.13 Expiration Date: March 20, 2019 Approval Date: May 10, 2018 E-1 ECO Windows Systems, LLC NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. New Evidence submitted. A. DRAWINGS 1. Drawing No. W12-08 Rev E, titled "Series 600 Alum Outswing Entrance Door (L.M.I.)", sheets 1 through 9 of 9 (inclusive 7.1), prepared by AL-Farooq Corporation, dated 02/13/12 and last revised on MAR 15, 2018, signed and sealed by Java Ahmad, P. E. B. TESTS 1. None. C. CALCULATIONS 1. Anchor verification calculations complying with FBC2017 (61h Edition), prepared by Al Farooq Corporation, dated OCT 31, 2017 and last revised on MAR 13, 2018, signed and shl-odby Javad��* Ahmad, P.E.(submitted under file 417-1102.18) : .... .' D. QUALITY ASSURANCE 0 0 0:0 * & : 0 * 9,5 1. Miami Dade Department of Regulatory and Economic Resources (RER).... :"": ...... E. MATERIAL CERTIFICATIONS """ "" ""' 1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc.*Tggner E.17 puPont'15%: o Nemours & Co., Inc. for the "Trofosil ® (Clear and Ultra clear) PVB:G&sl interlaxers", eYpiS4 on 07/08/19. 0 2. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company their "Saflex Clear & Color Glass Interlayer", expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance to FBC 5` Edition (2014) and FBC 611 Edition (2017) and of no financial interest, prepared by Al Farooq Corporation, dated 10/04/17, signed and sealed by Javad Ahmad, P.E. G. OTHER 1. This NOA revises NOA # 17-1218.15, expiring 03/02/2019. Is aq I. Chanda, P.E. Product Control Examiner NOA No. 18-0319.13 Expiration Date: March 20, 2019 Approval Date: May 10, 2018 E-2 ,a MULLION SYSTEM IS RATED FOR LARGE MISSILE IMPACT. AND CAN BE USED WITH ALL MIAMI-DADS COUNTY APPROVED IMPACT AND NON -IMPACT RESISTANT PRODUCTS. RECTANGULAR ALUMINUM TUBE MULL .ONS USING MULLION PROPERTIES ONLY NOTES: THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). ALL GLAZING PRODUCTS USED WITH THESE MULLIONS MUST MEET THE APPLICABLE BUILDING CODE REQUIREMENTS I.E: WIND LOAD, WATER INFILTRATION, FORCED ENTRY RESISTANCE, SAFEGUARDS ETC. 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING IRUCTIURE. ANCHORS SHALL -BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF S !NST+RUCTIONS. SPECtRED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON -COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUaD OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE Ra"IEWED BY BUILDING OFFICIAL. INSTRUCTIONS: USE CHARTS AND GRAPHS AS FOLLOWS. STEP 1 DETERMINE DESIGN LOAD REQUIRED PER ASCE 7 FOR PARTICULAR OPENING. S L—P 2 USE MIAMi-DADE COUNTY APPROVED GLAZING PRODUCTS MEFFNG ABOVE LOAD REQUIREMENTS. STEP USE CONNECTION TO MULLION AS PER PRODUCT APPROVAL. USING CHARS ON SHEET 3 SELECT MULLION SIZE WITH STEP 4 DESIGN RATING MORE THAN DESIGN LOAD SPECIFIED IN STEP 1 ABOVE. USING ANCHOR TYPES ON SHEETS 9 THRU 9 AND ANCHOR CHARTS STEP 5 ON SHEET 4, SELECT ANCHOR TYPE WITH DESIGN RATING MORE THAN THE DESIGN LOADS SPECIFIED IN STEP 1 ABOVE. II � I I II I I _ JI 4.000 6,000 I L2.000 III ;4__-� III I I 17 7L- i.J - - - - TYPICAL WINDOW FRAME TUBULAR SHAPES ALLOY = 6063-T6 —± --- i ,f,i ------ i — ! I II I I I IIII I ! 1Il I ! ! I fl I ! I II III II �H ---� TYPICAL 114J___3_I—GLAZING PRODUCT lJ 1.000 l 1 - ��11IJLtL_ LI LJJJ iiiJJJJ � i II i 3.000 4.000 MULLIONS CONTAINING TYPICAL GLAZING FRODUCTS HORIZONTAL OR VERTICAL SEE WINDOW OR DOOR APPROVAL FOR FASTENERS SITES AND SPACING PRODUCT REVISED as complying with the Florida Building Code NOA-No. 17-1=218.14 Explration Date 10/23/2019 By tj w 0 I Z M 4z CID 2 2 N [L iD 0 ac°v`�� WN GH O V p Ij 0aa< 0 yEX2 1 O Q W 5li Of a Win • O 7: 0 7— �t zmg L Q.uIMS _! •1 Z J 3 a) • o U "GR • • N� W ��• w } ac (A' � �... s•I+j C% 0 Q.:'i 00 Z LL. w Z >. ) uJ v p0 U are w Lc! Ca jo r •. TE OF ,l drawing no. NAI ONAL ,sheet 1 of 9 1.000 -{ 1.000 j� jam- 2.000 --�{ r .125 2.000 .125 2.000 250 W I I I I-Y �25 .375 �� 47--J� + 1.000 Z 1_000 125 o Z .125 .375 Q N a 125 .125 e u� .125 4.000 C C 4.000 t Owe 4.000 LIJ 3.00C I I a t - 3.000 I 125 6.000 6.000 0'0�� o 375 .375 L � I I 125 .250 QZ a OLLI :3 �N� 0 LU Ix = .9502 z. IN4 Ix = 20374 IN\4 Ix = 1.538 IN\4 Ix = 3.1878 IN\4 Ix = 2.9762 !N\4 \ I I N m Sx = .6335 INV Sx = 1.0187 IN\3 Sx = 1.0254 IN\3 5x = 1.5939 IN\3 Sx = 1.4881 IN\3 02 Z tM w L Q JO�� F- 1 X 3 X 4 1 X 3 1 X 4 2 X 4 I I STD. MULLION STD. MULLION , CUSTOM MULLION CUSTOM MULLION STD. MULLION i- i 6063-T6 5063-T6 I 6053-T6 6063-T5 6063-T6 �• I �' ...� • o0 •M Ig = 8.2757 IN\4 Ix = 15.2031 IN\4 CO CC) Sx = 2_7586 IN\3 Sx = 5.0677 IN\3 2 X 6 2 X 6 II .•X• STD. MULL IOI� F1EAV1' MULLION , • U) w 2E BCb i-T6 6063 T6 .: ti,1 ,,.Ws•- m • I m W, Ilo �s tn Z00 Z I3i ILL. cc j z 0I� J M Q II 0 � Q I 4I� co� i{mil .718 1.718 f i�l I ! � I I I L� 2.125 0 125 -125 I 2.125 La 125 o 125 rTT i I TYR i �1a I! I r 2.600 I I ►I � I'� I �I 5.500 5.500 IG-2.000 N I NOTCH NOTCH OPTIONAL I OPTIONAL 1/2' ,yyytllllt��� MIN of '\ l PRODUCT REVISED (: . 7 53i as complying with the Florida e / 1 j2p MIN. I Building Code I� 1 /2- MIN- NOA-No. 17-1.21 & 14 i MIN- ` e Expiration Date 10/23/2019 ® •. TATE '.��� drawing no. CLIP MULLION CLIP MULLION CLIP By '�,���®®•" '����`� t M 14-01 ANGLE Mi2rn a Product Control ��IONA� (sheet 2 of o 6063-T6 6063-T6 6063-T6 0 DESIGN LOAD CAPACITY - PSF (TUBE MULLIONS) DESIGN LOAD CAPACITY - PSF (TUBE MULLIONS) IPI,DOWDIMS. 1X3 STD. 1X4 STD. 1X3 CUSTOM 1X4 CUSTOMI 2X4 STD. 2X6 STD. 2X6 HEAVY WINDOW DIMS. 1X3 STD. 1 X4 STD. 1 R3 CUSTOM 1X4 CUSTOM 2R4 STD. 2R6 STD. 2%6 HEAVY WIDTH (W) MULL SPAN WIDTH (W) IMULL SPAN 1 9-1 /8" 26-1/2" 30" 37' 42" 48" 54" 60" 66" 72' 38-3/8" 1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 19-1 /8" 26-1/2' 30" 37" 42" 48" 54" 60" 66' 72" 74-1/4" 75.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 1 120.0 54.3 103.4 88.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120-0 120.0 120.0 12D.0 48.0 91.3 77.7 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 38.9 74.0 63.0 111.9 116.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 34.3 65.2 55.5 98.6 i 102.4 120.0 120.0 120.0 120.0 120.0 1120.0 120.0 120.0 120.0 30.0 57.1 4-8.6 86.3 ! 89.6 120.0 120.D 120.0 1 120.0 120.0 i 120.0 120.0 120.0 120.0 26..7 50.7 43.2 76.7 79.7 1 120.0 120.0 112.5 120.0 120X 120.0 120.0 120.0 120.0 24.0 45.7 38.9 69.0 71.7 120.0 120.0 102.3 120.0 120.0 120.0 120.0 120.0 120.0 21.8 1 41.5 35.3 62.7 65.2 119.7 120.0 93.8 120.0 120.0 120.0 120.0 120.0 120.0 - 38.0 32.4 57.5 59.7 109 7 120.0 19-1/8" 26-1/2' 30" 37" 42" 54' 60" 66' 72" 42' 120.0 120.0 120.0 120.0 120.0 120.0 120.0 19-1/8' 26-1/2' 30" f 37" 1 42' 48" 54" 60" 66" 72" 84' 52.0 110.6 84.2 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 1 120.0 120.0 1 120.0 37.5 79-8 60.8 120.0 117.7 120.0 120.0 120.0 120.0 120.0 120_0 1 120.0 120.0 ' 120.0 33.2 70.5 53.7 106.3 104.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 j 120.0 26.9 57.2 43.5 I 86.2 I 84.3 i20.0 1120.0 120,0 120.0 120.0 i 120.0 120.0 120.0 120.0 23.7 5C.4 I 38.3 76.0 1742 1120.0 j 120.0 116.8 120.0 120.0 120 0 120.0 120_0 120.0 20_7 j 44.1 33.5 I 66.5 65.0 120.0 120.0 103.8 120.0 120.0 120.0 1120.0 120.0 120.0 - 39.2 29.8 59.1 57.8 113.5 120.0 93.4 120.0 120.0 120.0 120.0 120.0 120.0 - 35.3 26.8 53.2 52.0 102.2 120.0 84-.9 120.0 120.0 120.0 120.0 120.0 120.0 - 321 24.4 48.3 47Z 92.9 120.0 77.9 120.0 120-0 120.0 120.0 12C.0 120.0 - 29.4 22.4 44.3 43.3 6-5.2 120.0 19-1/8" 26-1/2" 30" 37' 42" 48" 54" 60" 66" 72" I 50-5/8" 1-20.0 1120.0 120.0 120.0 120.0 120.0 120.0 19-1/8' 26-1/2" 30" 37" 42" 48" 54" 60" 66" 72" 96" 34.8 74.8 56.4 116.9 109.3 120.0 1 120.0 120.0 120.0 120.D 120.0 120.0 120.0 120.0 25.1 54.d 40.7 84.4 78.9 120.0 120.0 120.0 120.0 120.0 1-20.0 120.0 1120.0 120.0 22.2 47.7 3 36.0 I 74.5 69.7 120.0 120A 103.1 120.0 120.0 120.0 120.0 120.0 120.0 - 38.7 29.2 f 60.4 56.5 120.0 i 120.0 90.8 I 120.0 ( 120.0 ' 120.0 120.0 120.0 120.0 - 34.1 25.7 53.2 49.8 110.9 L 20.0 79.5 120.0 120.0 120.0 120.0 120.0 120.0 - 29.8 22.5 46.6 43.5 I 97.0 120.0 70.6 I 112.5 111.E 120.0 120.0 120.0 120.0 - 26.5 - 41.4 i 38.7 862 120.0 63.5 101.3 100.4 120.0 120.0 120.0 i 120.0 - 23.8 - 37.3 34.8 ; 77.6 120.0 57.8 92.1 91.3 120.0 120.0 120_0 120-0 - 21.7 - 33.9 31.7 70.6 120.0 53.0 84.4 83.7 120.0 120.0 120.0 120.0 - - - 31.1 29.0 I 64.7 118.3 19-1/8" 26-1/2" 30" 37" 42" 48' 54" 60" 66" 72" 63" 1 I 120.0 120.0 120.0 120.0 1120.0 120.0 120.0 19-1/8" 25-1/2" ! 30" ; 37" 42" 48' 54" 60' 66" ( 72" I I j i 108" - - - 82.1 76.8 120_0 1120.0 89.0 i 120.0 1120.0 120.0 120.0 120.0 120.0 - - - 59.3 1 55.4 120.0 1-20.0 78.6 120.0 i 20.0 i 12C.0 120.0 120.0 120.0 - - - 52.3 48.9 i 120.0 120.0 £ 63.7 10-10 1032 120.0 ! 120.0 120.0 120.0 - ! - - 42_4 39.7 ' 98.7 120-0 56.1 91.9 90.9 120.0 120.0 120_0 120.0 I 37.4 35.0 I 87.0 120.0 49.1 80.4 79.5 120.0 ► 120.0 120.0 120.0 - - - 32.7 30.6 76.1 120.0 43.7 71.5 70.7 108.3 111.5 1120.0 120.0 - - - 29.1 27.2 67.6 120.0 39.3 64.3 63.6 97.5 1100.3 120-0 120.0 - - ; - 26.2 24.5 60.9 111.3 35.7 58.5 57.3 88.6 i 91.2 120.0 120.0 I - - - 23.8 22.2 55.3 101.2 32.7 53.6 1 53.0 81.3 83.6 ? 20.0 120.0 - i - ! - 21.8 20.4 50.7 92.7 ALL LOADS ARE EXT."-)/1NT.(-). NOTE. MULLIONIS RATED IN THESE CHARTS MAY BE ORIEN T E7D VERTICALLY OR HORIZONTALLY. (INTERPOLATION BETWEEN WIDTHS ALLOWED) DESIGN LOAD CAPACITY - PSF (TUBE MULLIONS) WINDOW DIMS. 1X3 STD. 1 X 4 STD. 1 X 3 CUSTOM 1 X 4 CUSTOM 2 X 4 STD, 2 X 6 STD. 2 X 6 HEAVY WIDTH (W) MULL SPAN 19-1/8" 26-1 /2' W. 37" 42" 48' 54" 60" 66' 72' 120' - - - 59.9 564 120.0 120.0 - - - 43.2 40.4 110.9 120.0 - - - 38.2 35.7 97.9 1 120-0 - - - 30.9 28.9 79.4 120.0 - - - 27.3 25.5 69.9 120.0 - - - 23.8 22.3 61.2 111.8 - - - 21.2 - 54.4 99.4 - - - - - 49.0 89.5 - - - - - 44.5 81.3 - - - - - 40.8 74.6 19-1/8" 25-1/2" 30" 37" 42' 48' 54" 60" 66" 72' L 132" I - - - 45.0 42.0 116.8 120.0 - - - 32.5 30.3 84.3 120.0 - - - I 28.7 26.3 74.5 120.0 - - - 212 21.7 1 60.4 110.8 - - - 20.5 - 53.2 ; 97.6 _ - - - - 45-5 85.4- - - - - - 41.4 75.9 - - - - - 37.2 68.4 - - - - - 33.8 62.1 - - - - - 31.0 57.0 19-1/8" 26-1 /2" 37' 42' 48" 54' C-0' 66' 72' I i 144" - - - 34.6 32.4 90.0 120.0 - - - 25.0 23.4 64.9 119.2 22.1 20.6 1 57.4 105.3 - - - - { - 46.5 55.4 - - - - I - 41.0 75.2 - - - - 35.8 65.8 - - - - - 31.9 58.5 - - - - I - 28.7 52.6 - - - i - - 25.1 47.9 - - - i - I - 23.9 43.9 ARCHES TO BE INSCRIBED IINSME -RECTANGULAR S.WE !I VERTICAL MULLION GLAZING GLAZING PRODUCT Z PRODUCTS ill W1 I � N2 T"ICAL MULLION ARRANGEMEN HORIZONTAL MULLION F GLAZING PRODUCT GLAZING {' GLAZING I I PRODUCT PRODUCT ` I I i MULLION SPAN j PRODUCT REVISED 1�/iDTi ! (�t�l) = W/7 T as complying with the Florida 2 Building Code IVOA-No, 17-1218.14 Expiration Date 10/23/2019 MULLIONS By Mia rD Product Control y�VLJ LJ V) [to Zq F 'o z o r Z N Ooo°J N a U, ilr a LL Q�CQ,o! C 0 oy7 O LU t0 LL Z J Z M ' w 0 � I sT3aTE()F dra ing no. Az i ONAL �\```�(sheet 3 of g r DESIGN LOAD CAPACITY - PSF WINDOW DIMS. ANCHORS TYPE WIDTH (W) MULL SPAN A2 A4 A6 B2 B4a Bob 26-1 /2" 30" 37' 42" 48" 54' 60" 66" 72" 1 38-3/8" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120-0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 101.4 120.0 120.0 120.0 120-0 120.0 89.3 120.0 120.0 120.0 120.0 120.0 78.2 112.6 120.0 108-4 120.0 120.0 69.5 100.1 12A.0 97.6 I 120.0 120.0 62.5 90.1 120.0 88.7 120.0 120.0 56.9 81.9 113.7 81.3 120.0 120.0 52.1 75.0 104.2 26-1 /2" 30" 37' I 42' 48" 54' 60" 66' 72- 42" 120.0 120.0 120.0 120-0 1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 114.3 120.0 120.0 120.0 1 120.0 120.0 92.7 120.0 120.0 120.0 ( 120.0 ; 12C.0 81.6 117.6 120.0 111.4 1 120.0 120.0 71.4 102.9 120.0 99.0 120.0 120.0 63.5 91.4 120..0 89.1 120.0 120.0 57.1 I 82.3 114.3 81.0 120.0 120.0 I 51.9 1 74.8 103.9 74.3 120.0 120.0 47.6 68.6 95.2 19-1/8" 26-1/2" 30" 37" 42' 48' 54" 60" c6' 72" ( I I 50-5/8" 120.0 120.0 120.0 120.0 I 120.0 120.0 120.0 120.0 120.0 107.3 120.0 120.0 120.0 120.0 120.0 94.8 T20.0 120.0 119.9 120.0 120.0 76.9 110.7 120.0 105.7 120.0 120.0 67.7 1 97.5 120.0 92.4 120.0 120.0 59.3 1 85.3 118.5 82.2 120.0 120.0 52.7 75.9 105.3 74.0 , 20.0 1 120.0 47.4 68.3 94.8 67.2 11.1.2 120.0 43.1 62.1 55.2 61.6 107.5 120.0 39.5 56.9 79.0 19-1/8" 26-1 /2" 30" 37' 42" 4-8' 54" 60" 66' 72" I 63" i 120.0 f 120.0 I 120.0 1 119..5 120.0 120.0 , 20.G 120.0 t2O.0 1 86.3 120.0 i 120.0 118.9 120.0 120.i 1 762 109.7 120.0 96.4 1.20-0 1,20.0 61.8 89.0 120.0 84.9 120.0 I 120.0 54.4 78.4 108.8 74.3 120.0 120.0 4-7.6 I 68.6 95.2 66.0 115.1 120.0 42.3 61.0 84.7 59.4 103.6 i 120.0 1 38.1 54.9 76.2 54.0 94.2 120.0 1 34-6 49.9 69.3 49.5 86.3 1 120.0 1 31.7 45.7 63.5 DESIGN LOAD CAPACITY - PSF WINDOW DIMS. ANCHORS TYPE WIDTH (W) MULL SPAN A2 A4 A6 B2 B4a 134b 19-1 /8' 26=1/2" 30" 37" 44' 48" 54" 60' 66' 72" 74-1 /4" 1 120.0 120.0 120.0 101.4 120.0 120.0 114.2 120.0 120.0 73.2 105.4 120.0 100.8 120.0 120.0 64.6 93.1 120.0 81.8 120.0 120.0 52.4 75.5 104.8 72.0 120.0 120.0 452 66.5 92.4 63.0 109.9 120.0 40.4 58.2 80.8 56.0 97.7 120.0 35.9 51.7 71.8 50.4 87.9 120.0 32.3 1 46.5 64.6 45.8 79.9 119.9 29.4 42.3 58.8 42.0 73Z 109.9 26.9 38.8 53.9 19-1/8" 26-1/2' 30" 37' 42' 48" 54" 60" 66' 72" ` f 84" 120.0 120.0 120.0 B9.6 120.0 120.0 100.9 120.0 120.0 64.7 93.2 120.0 89.1 120.0 120.0 57.1 52.3 114.3 72-3 120.0 120.0 46.3 66.7 92.7 6<:.7 j 111.0 , 120.0 40.8 I 58.8 81.6 55.7 i 97.1 1 120.0 35.7 51.4 71.4 49.5 85-3 120.0 1 31.7 45.7 63:5 44.6 I 77.7 116.6 1 28.6 41.1 57.1 40.5 70.6 I 106.0 26.0 37.4 51.9 37.1 64.8 97.1 23.8 34.3 47.6 19-1/B' 126-1/2' 30" 37- 42' 4a' 54" 80' 66" ' 72' I I I gs" ' 120.0 120.0 120.0 78.4 11.2.9 120.0 88.3 120.0 120.0 56.6 81.5 113.2 7&0 120-0 j 120-0 50L 720 100.0 63.2 110.3 120.0 405 58.4 81.1 55.7 97.1 120.0 35.7 51.1, 71.4 48.8 85.0 120.0 312 45.0 62.5 43.3 75.5 113.3 27.8 40.0 55.5 39.0 68.0 102.0 25.0 36:0 50.0 35.5 61.8 92.7 22 7 i 32-7 45.5 F 32.5 56.7 85.0 20.8 .30-0 41.7 19-1/8" 26- i / 2' 30" 37" 42" ,a. 54' 60" 66' 72" I i ! i 108" 108.8 120.0 120.0 69.7 100.4 120.0 78.5 I i 20.0 120.0 -50.3 E 72.5 I 100.6 69.3 120.0 120.0 44.4 I 64.0 88.9 r 56.2 9E.0 , 20.0 36.0 ' 51.9 72.1 49.5 86.3 I 120.0 31.7 45.7 63.5 43.3 75.E 113.3 27.8 40.0 55.6 38.5 61.2 100.7 24.7 35.6 49.4 34.7 604 90.7 22.2 32.0 44.4 31.5 54.9 82.4 20.2 29.1 40.4 28.9 50.4 t 75.6 25.7 37.G r ALL LOADS ARE EX i .(; NOTE: MANY ANCHOR CONDITION SHOWN HEREIN MAY COVER LOCA!!ONS AT HEAD, SILL OR JAMB ENDS. FOR ANCHORS DESCRIPTON SEE SHEETS 5 THRU 9. (INTERPOLATION BETWEEN WIDTHS OR SPANS ALLOWED) DESIGN LOAD CAPACITY - PSF WINDOW DIMS_ ANCHORS TYPE H (W) MULL SPAN A2 A4 AG B2 B4a Bob r26-1/2- 30' 37" 42" 48" 54" 60" 66" 72" 120" 97.9 120.0 120.0 62.7 90.4 120.0 70.6 120.0 12a.0 45.3 65.2 90.6 62.4 108.8 120.0 40.0 57.6 80.0 50.6 88.2 120.0 32.4 46.7 64.9 4-4-5 77.7 116.6 28.6 41.1 57.1 39.0 68.0 102.0 25.0 36.0 50.0 34.7 60.4 90.7 22-2 32.0 44.4 31.2 54.4 81.6 20.0 28.8 40.0 28_4 49.5 I 74.2 - 262 36.4 26.0 45.3 68.0 - 24.0 33.3 19-1/8- 26-1/2" 30' 37' 42" 48" 54" 60' 66" 72" i I 132" 89.0 120.0 120.0 1 57.0 82.1 114.1 64.2 112.0 120.0 41.2 59.3 82.3 56.7 98.9 120.0 36.4 52.4 72.7 46.0 1 80.2 120.0 29.5 42.5 I 59.0 40.5 70.6 , 106.0 26.0 37.4 I 51.9 35.5 61.8 92.7 227 I 32.7 45.5 I 31.5 54.9 82.4 20-2 29.1 40.4 2S.Y I 45.5 74.2 - 26.2 i 36.4 25.8 45.0 67.4 - 23.8 1 33.1 23.6 41.2 61.8 - 21.8 30.3 19-1/8" 26-1 /2' 30" 37' 42' 48" 54" 60" 68" 72" 144' I 81.6 120.0 120.0 1 52.3 75.3 1 104.66 Sd 9 1 120-0 ` 37.7 I 54.3 I ; �.5 25 0 j 90.7 I 120.0 48.0 66.7 42.2 73-5 1 110.3 I 27.0 37.1 64.8 97.1 23.8 34.3 47:6 • 32.5 56.7 85.0 20.8 30.0 4-1.7 28.9 50.4 75.6 - 26.7 37.0 26.0 45.3 68.0 - 24.0 33.3 23.6 41.9 6i.8 - 21.8 30.3 21.7 37:8 I 56.7 I - 20.0 27.8 ARCHES TO BE WSCRBED TYPICAL F iNSIDE RECTANGULAR SHAPE TYPICAL ANCHORS i ANCHORS t HORIZONTAL MUWON � 1 VERi1CP.L ! MUWaN I z - oI,Iz GLAZING Ij GLAZING PRODUCT II PRODUCT TYP11CAL ANCHORS W, GLAZING PRODUCT \�I A,NCHOP. I h i GLAZING GLAZING TYPICAL PRODUCT 1 PRODUCT ANCHORS MULtiON SPAN TYPICAL MULLION ARRANGEMENTS �A.N4u 2 � � � . • titG 'Sir PRODUCT REVISED j� 170591 as complying with the Florida - �{ Building Code +' NOA-No. 17-1218.14 X `i� •� TbE10E OF Al. Expiration Date 10/23/2019 ANCHORS ;�'� .. GR'g�..•-�; _---- ` Miami- a Product Control/// ® L k\ w 0 I Z n 2 M 9 o Q� �C4 iL � 00` 0W CL a 1. 0 LO f f a rui � Ors'-M C� 0 0Q ° O WN d W N W t� W 0 � II drawing no. M14-01 sheet 4 of 9 0 u 1 IL___--_----1 i I I I II II it 9 8 P TYPICAL ANCHORS TYPICAL ANCHORS 2 PER CUP (1 ON EACH WING) 1 PER ANGLE \N4 � FLOATING CLIP +i ij 11 Ij! 4 I I II 11 I I I! ! I I ! II 11 I SNUG FIT INSIDE MULL U U #14 SMS 1 #14 SMS I I 1-3/4" O.C. MIN. I I 1-3/4" O.C. MIN. I I 4 PER CLIP 2 PER ANGLE NNCN_ORS TYPE `N2' TYPICAL ANCHORS 4 PER CUP (2 ON EACH K!NG) \\, '14 1, -#14 SMS 1-3/4" J.C. MIN. 4 PER CLIP ANCHORS TYPE `A4' FLOATING CUP SNUG FIT INSIDE MULL CO\NC-REiE\ OR 2X 2X1/8" ALUM ANGLE TYPICAL ANCHORS 2 PER ANGLE OR #14 SMS 1-3/4" J.C. V!N-. 2 PER ANGLE 1I II II tl II 11 /2X2X 1/8" i1 L11 ALUM ANGLE I 1 � I TYFIt— ANCHORS: ANCHOR TYPES SUBSTRATE MIN. EMBED. MIN. EDGE DIST. 1/4" DID,. ULTRACONS BY `ELCO` (Fu=177 KSi, Fy=155 KSI) CONCRETE I 1-3/4" I 2-1/2" 1/4" DIA. SELF DRIVING SCREWS (GRADE 5 CRS) ME CONCRETE = f'c = 3000 PSI MIN - METAL = 1 /8" MIN. THK. STEEL Fy = 36 KSi MIN. 1/8" MIN. THK. ALUMINUM (6Q63—T5 MIN.) ANCHORS MAY BE HEX 0 FLAT HEAD. E — ALL CLIPS AND ANGLES TO FIT SNUG INTO TUBE MULUONS. CUPS OR ANGLES CONNECTED DIRECTLY TO MASONRY TO BE FROTECT u WITH ALKALI —RESISTANT COATINGS, SUCH AS BITUMINOUS PAINT OR WATER —WHITE METHACRYLATc LACQUER_ �i w I o Z n O Z M O W 4N 2 Cq M 0 a Cl�C-4 �nr 0 t M, v O Lu d CIF o�p 0tl;y it UM) �� N Lazy= � 0 QWM •GR • • ILr -J • �1 °° Ld •••Y• 1 !1 1 1 171, 17 is Irk on i n PRODUCT REVISED / 705 as complying with the -Florida Building Code NOA—No. 17-1218.14 Expiration Date 10;23/2019 " OF �� ' drewing no BY ������.•����,� M14-01 .alssssNsheet 5 cf 9 , TYPICAL ANCHORS 6 PER CUP (3 ON EACH WING) TYPICAL ANCHORS 3 PER ANGLE Ot RI'TE� \ 4 -d t1 II t! II q-------- I------------�I Lj If7LOATING CLIP 11 11 /2X X 1/8" ! ! SNUG FIT INSIDE MULL u U ALUM ANGLE #14 SMS J 1 �( J14 SMS I 1-3/4" O.C. MIN. i 1 �� 1-334PER ANGLE) I 1 6 PER CUP ANCHORS TYPE `A6' ANCHOR TYPES ; SUBSTRATE MIN. EMBED. MIN. EDGE DISTt 1/4" DIA. ULTRACONS BY 'ELCO' CONCRETE 1-3/4" I 2-1/2" (Fu=177 KSI, Fy=155 KSI) 1/4" DIX SELF DRILUNG SCREWS METAL 1/8" 3/4" (GRADE 5 CAS) .1 CONCRETE = f'c = 3000 PSI MIN. METAL = 1/8" MIN. ThK_ STEEL Fy = 36 KS! MIN. 1/8" MIN. THK. ALUMINUM (6063-T5 MIN.) ANCHORS MAY BE: HIs OR FLAT HEAD. iALL CUPS AND ANGLES TO F17 SNUG INTO TUBE MULLIONS. CLIPS OR ANGLES CONNECTED DIRECTLY TO MASONRY TO BE PROTECTED WITH ALKALI -RESISTANT COATINGS, SUCH AS BITUMINOUS PAINT OR WATER -WHITE MtiHACRYLATE LACQUER. PRODUCT REVISED as complying with the Florida Building Code NOA-No. 17-121 & 14 Expiration Date 0/23/2019 By �u � w M a I Z ti z "�' o N Q2 N J IL � >a p O N ti M N X pLLJ L ei O�O�M o pao O� aQ' 1 zo O Q LU 0 LL , �z�� �aZCM • • N go U i . • {q J ic -SiCD • • •J� {n : • • 0 .. I L ••a-c LL w • I�.••;iu" w h t �.!0I' ?- iY �11iD j� •iCi•i ••I i� *�j-trM rn z Z LL_ co 2� N_ aIIU Ln o� I. 1W °OM F- Iu m 'LL In °Io Ei E G7a nI - L. 4 f},0, Olralr t1lSlti'l� ��� G) i I a+'!EY �9�% OF � drawing no. SOP.• 6\,�� M 14-01 ���jj jjjIt itt� �� i of 9 1 a u 0 i C11, 1L-------------� it I TYPICAL ANCHORS 2 PER CUP (1 ON EACH WING) \BNC\ TYPICAL ANCHORS 1 PER ANGLE OR I! II ii II I! Ij II II jp y FLOATING CLIP i 1 SNUG FIT INSIDE MULL Li U #14 SMS_/ 1 1 #14 SMS 1-3/4" O.C. MIN. 1 I 1-3/4" C.C. MIN .J I 4 PER CUP �, 2 PER ANGLE ii r kNCiORS TYPE `R2' TYPICAL ANCHORS _ 4 PER CUP (2 ON EACH >ING___� II III LFLOATING CLIP SNUG FTT INSIDE MU?1 jI II #14 S!S � it i� I� #14 SMS O.C. M!N. - 1 -3/4" O.C.m N. 4 PER CLIP 2 PER ANGLE NCHORS TYPE `B4 ' TYPICAL ANCHORS 2 PER ANGLE 2X2X1/8" ALUM ANGLE II Ilr / II Ij / II II � !1 lli �2X2X1/E' `JI ALUM. ANGLE I RE RE _ i t O -• i TYPICAL ANCHORS: ' ANCHOR TYPES SubSFRATE MIN. EMBED. MIN. EDGE DISZ. 1/4' DIA. ULTRACONS BY 'ELCC' (Fu=177 KSI, Fy-155 KSi) MASONRY 1-3/4" 2-T/2' WOOD 1-1/2" 1' • WOOD = 2BY WOOD BUCKS OR WOOD STRUCTURE S.G. = 0.55 MIN. MASONRY = C-90 HOLLOW/FILLED BLOCK f'm = 2000 PSI MIN. IBY OF: 2BY WOOD BUCKS NOT B'Y ECO WINDOW MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO BUILDING STRUCTURE. ANCHORS MAY BE HEX OR FLAT HEAD PRODUCT DEVISED as complying with the Florida Building Code NG ► No. 17-1-218.14 F),�ratzon Date- 0123/2019 By -� :1 M• . • w •• • • En�ty • (n• cn to •'gym CO I 0 —j Co ,O 0 E-nW 1� gi I 04 li it �L-------------------- �I li W I� Z TYPICAL ANI CHORS " Of TYPICAL ANCHORS 2 PER ANGLE O � z 4 PER CLIP (2 ON EACH WING) yZj N O 0 D L \ a `� O ; M W D UR I � I I W@0 U TU ELLI a C�351)h 111 II I II II / I Iv Quid ill II I1 0 11 IYE [Log c jl II II I1 j I an L2 N U FLOATING CUP j I I j X 2 X 1/8" 1 4; z 0 N SNUG FIT INSIDE MULL LI u, ALUM ANGLE .S N Din 1-3/4" O.C. MIN. i I 1-3/4" O.C. MN. 1 [� Z p 8 PER CUP I � - 3 PER ANGLE ', Z M Q Z 2+9 - iu IQsum�� i • • I v •• •�� M! ••a• TYPiC_41 .NCHORS: ••�!1 fw L .. ¢ i ANCHOR TYPES SUBS r.ATE MIN. EMBED. MIN. EDGE DIST. 0• • • Gr) Lj • � j 1 /4" DIA. U-TRACONS BY ' ELCO' MASONRY 1-3/4" 2-1 /2" r V) �� • � (Fu=177 MtiE: FY155 KSI) W000 1-1/2" 1" • [�r 1i • I ?r' +. ia'T d NCHORS TYPE 'B4b' WOOD = 2BY WOOD BUCKS OR WOOD STRUCTURE S.G. = 0.55 MIN. I Q 00 MASONRY = C-SO HOLLOW/FILLED BLOCK f'm = 2000 PSI MIN. Z', Z 3� U- CID '0 r [BY OR 2BY ;MOOD BUCKS NOT BY ECO WfNnn':' o MUST SUSTAIN LOADS EMPOSED BY GLAZING SYSTEM AND TRANSFER Q I O p 0 LJ THEM TO -BUILDING STRUCTURE. W m ;a; AINCHORS MAY BE HEX OR FLAT HEAD. 1 _ 1 ITO TO �C N O o 71 q RI PRODUCT REVISED I _= N 73 as complying with the Florida t _ m Building Code _ I m I NOA-No. 17-1218.14 ' Expiration Date 10/23/2019 , ® ?�OF �4- ri drowir,g no. M 14-01 By miam oduct Control �/j�®�NAL �i ',Sheet $ of S IIV f14 SMS SEE CHART FOR QUANTITIES TUBE MULLION OM J14 FH SMS_f U 2/ SIDE i 1 1/8" THICK ALUM CHANNEL I LENGTH TO FIT SNUG/i INTO MULLION TUBE MULLION I I I l TUBES MAY BE NOTCHED AS SHOWN TO ALLOW INSTALLATION OF CLIP ANGLE CAULK JOINT AFTER ASSEMBLY #14 FH SMS 1-1 /2" O.C. MIN. ACCESS HOLE- SEE CHART FOR QUANTITIES THIS SCRINSTALLED I CAN ER vl- DIRECTION INSTALLED IN EITHER IL21PER CUPS - I I 1" O.C. MIN. I I 1-3/4- X 2" X 1/8" (FOR 2BY TUBE) 3/4' X 2" X 1/E" FOR (1BY TUBE) ALUM ANGLE CI17 TO rFRT SNUG iNSiDE TjBE ANCHORS DETAIL n1 METAL TO METAL CONNECTION #14 SMS SUBSTRATE .Ed. = MIN. EDGE DIST.'M1N. CL TO CL SPACING ALUMINUM 1 5/8. 1 1/2- ANCHOR CHART NO. OF SCREWS TYPE A2 2 TYPE A4 3 TYPE A8 4 PRODUCT REVISED as complying with the Florida Building Code Mot►_ -No. 17-1218.14 Expiration Date 10/23/2019 a- iillia rDa ,,duct Control �Ip I Z 0z o Lu N Q2 N IL W U. 0 t N M Opl,i� �fr5� o 0ILao 0 0 N0 N O ` N � Cn W a C) L �! • • e • • N ...0 •47. •y. • 'n �O • .o • .o •�i >- LL • • 0Oro. �1 Z U-z co I as 'I Sly Z` o 'IIILLJ 0 00 "! U 'n L" W L�.i co� W �`�°�.•' s..; 70592 / s OF � drawing no. I IN INSTRUCTIONS: USE CHARTS AS FOLLOWS. STEP 1 SEE CHART #1 ON SHEET 5 FOR GLASS CAPACITY AND REINFORCING REQUIREMENTS. STEP 2 SELECT SILL TYPE FROM SHEET 7 AND LIMIT EXT.(+) DESIGN PRESSURE AS SHOWN ON DETAIL. STEP 3 SEE CHART #2 ON SHEET 5 FOR ANCHOR CAPACITY. STEP 4 THE LOWEST VALUE RESULTING FROM STEPS 1 THRU 3 SHALL APPLY TO ENTIRE SYSTEM. DAYLITE OPENINGS WIDTHS: FIXED STILE -INTERLOCK = PANEL WIDTH - 7.125" INTERLOCK -ASTRAGAL = PANEL WIDTH - 7.250" DAYLITE OPENING HEIGHT: PANEL HEIGHT - 6.50" PANEL HEIGHT = DOOR FRAME HEIGHT - 1.5625" THESE DOORS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. SERIES-700 ALUMINUM SLIDING GLASS DOOR THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE _ DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON -COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL. a a C 4 3/8" CLUSTER OF 6 ANCHORS 5" MAX. 13" MAX. TYP' AT INTERLOCK ENDS HEAD - `\- SEE SHEET 5 FOR CAPACI CORNERS Q R" DOOR FRAME WIDTH A ' INTERLOCKS WITH OR WITHOUT I I I I -REINFORCING - �- SEE CHART 1 I i II II II II I I C E L=-- I I D COLd LU LT o- w I 0 o a- II II a Q a ===7F==-=�T=== I) II I I II II II II II II it l B 41 3/4" 41 3/4" FALSE MUNTIN D.L. OPG. D.L. OPG. OPTIONAL 48 7/8" PANEL WIDTH 48 7/8" rr�rvcL MUM n 5" MAX. - \---' -- SILL 13" MAX. g CORNERS SILL �Q CLUSTER OF 6 ANCHORS _/ AT INTERLOCK ENDS SEE SHEET 5 FOR CAPACITY TYPICAL ELEVATION OX ALTERNATE SIZE UNITS: MAX. FRAME AREA OF DOORS NOT TO EXCEED THE TESTED FRAME AREA OF 72 SQ. FT. TY V0 0)�y� W M ^� aD Z M r 0Z rn F� �' a W � I Q (L O W cv ` l° o tV X a- LL 0 v51)M 0 La 0�o?M o 0 aoa NN0 QwntLL: • W 0 _� •• JZc°ca • I Z 1OR go R • 0 m Q N m m az 0 U "08UC r REY i;3M as oomp4ist with the Fi **b ludaog Code A*m#taaee No IV-0) ?-I?- / 3 OateM- 69--z ,Aol-j LAMINATED - GLASS INSUL. LAM. GLASS LARGE MISSILE IMPACT .70 2 3 2 i? o®�• 3T OF • • V) W m W M o a O r o a o a w a W a t'i a W =1 W- _ vl O I O I N O M o N O o ~ m a O �F v m T u drawing no. W 13-49 sheet 1 of rr�rvcL MUM n 5" MAX. - \---' -- SILL 13" MAX. g CORNERS SILL �Q CLUSTER OF 6 ANCHORS _/ AT INTERLOCK ENDS SEE SHEET 5 FOR CAPACITY TYPICAL ELEVATION OX ALTERNATE SIZE UNITS: MAX. FRAME AREA OF DOORS NOT TO EXCEED THE TESTED FRAME AREA OF 72 SQ. FT. TY V0 0)�y� W M ^� aD Z M r 0Z rn F� �' a W � I Q (L O W cv ` l° o tV X a- LL 0 v51)M 0 La 0�o?M o 0 aoa NN0 QwntLL: • W 0 _� •• JZc°ca • I Z 1OR go R • 0 m Q N m m az 0 U "08UC r REY i;3M as oomp4ist with the Fi **b ludaog Code A*m#taaee No IV-0) ?-I?- / 3 OateM- 69--z ,Aol-j LAMINATED - GLASS INSUL. LAM. GLASS LARGE MISSILE IMPACT .70 2 3 2 i? o®�• 3T OF • • V) W m W M o a O r o a o a w a W a t'i a W =1 W- _ vl O I O I N O M o N O o ~ m a O �F v m T u drawing no. W 13-49 sheet 1 of a a C CLUSTER OF 5" MAX. 13" MAX. 4 3/8" 6 ANCHORS AT GAL HEAD HEAD TYP. - SEE SHEET C5/FOR RCAPACITY ENDS CORNERS Xz' - �A 8, DOOR FRAME WIDTH A ' INTERLOCKS WITH OR WITHOUT - I ----_� _____1 - �_ II II II REINFORCING SEE CHART #1 II � H C II II =__ === G D �c---- W e = W n = if O to LJ 0 O Z a O 11 II I I V p r=-- II II II II II II I I �I I� I I B 42 1/16" 42 1/16" FALSE MUNTIN D.L. OPG. D.L. OPG. OPTIONAL 49 3/16" 49 5/16" PANEL WIDTH PANEL WIUIH ASTRAGAL INTERLOCK i 5" MAX. SILL 13" MAX. CLUSTER OF CORNERS SILL 6 ANCHORS 5 �Q. AT INTERLOCK/ASTRAGAL ENDS TYPICAL ELEVATION SEE SHEET 5 FOR CAPACITY OXX ALTERNATE SIZE UNITS: MAX. FRAME AREA OF DOORS NOT TO EXCEED THE TESTED FRAME AREA OF 110.7 SQ. FT. m m Qz o U Vh. U w rn I - m rr O °f Z M W Q I N IL li Opp a O O W v U N G=� 0 cr m 0 O aoQ O It W?O cog � Qt` m • • • • W N.�i l•ZC� c. ... to •. . O J tillb • •I ro • • LD /� •••.o • v • g LLJ F-�•• x Lv • • w V) CO r7 ,� Q 0 Z �� m O C) Z > W W O O N W H Z U Z m WM Nwbuc��ypt� �+���,�i i ii'+ NED O V O U O compty'ixg with tit¢ Fled& o � � o o ARCtt�O 't7 i 29 . C a Ww a w xgkttwp Data 2Q U N a Zi a mw ft— Pbalani 4'IriiMAi C U;--2 O j 1 N p \ r N 70592 i Cj N$ O y ° S E OP •��� drawing no. I,—%%\0 sheet 2 of1� �I CLUSTER OF 5" MAX. HEAD 13" MAX. 4 3/8" HEAD TYP. 6 ANCHORS AGAL SHEET C5/FOR RCAPACITY ENDS CORNERS _ --SEE 192" �A 6. DOOR FRAME WIDTH � lH C 2 w _ _ ao n w = a O � LO to J W J O Q cn 0 a FALSE MUNTIN OPTIONAL 5" MAX. SILL CORNERS INTERLOCKS WITH OR WITHOUT REINFORCING II II SEE CHART #1 II II II II II II II II I 1 I I I I �I I� II II I I II II II II I I II II �I I� II �II D / 42 1/16" I I 42 1/16" D.L. OPG. D.L. OPG. 49 3/16" PANEL WIDTH 49 5/16" PANEL WIDTH INTERLOCK ASTRAGAL i 1LMAX. ° SILL h �Q TYPICAL ELEVATION OXXX INTERLOCKS WITH OR WITHOUT REINFORCING SEE CHART #1 H INTERLOCK i -- CLUSTER OF 6 ANCHORS AT INTERLOCK/ASTRAGAL ENDS SEE SHEET 5 FOR CAPACITY ALTERNATE SIZE UNITS: MAX. FRAME AREA OF DOORS NOT TO EXCEED THE TESTED FRAME AREA OF 144 SQ. FT. r- m Ld mcr Ld aaf �o � U 9s ampp4int1 will, fe Atccpttsce No 1 U 1 Z �3 zq&Odm pate za 19 �1111111/�� EN s N .70592 9a°• s OP Z M ti 3 0 °' -Z M 04 Q z W Q a � N d O W cv ` M o cl cc C 1= O Vyti v ni ei O`0>M o O Ny2 QMZAAl N • W D Ii. • • �W y S ZO2.✓ • � 10 W m �•H •• •.•�' Q• OO OD 4 • • WLLI L M C� (n w. • ti Z V) cp o V N 3'. -c rn 0 ;M C a Z 0 0 Z>- w W o 0 04 N W 00 m r I(sheet 3 of 12 ) . 1 2 w lL c c c F x a c c c x 4 Q LL a c c c DOOR FRAME W. A C E D a I OX (SHOWN) XO XX DOOR FRAME WIDTH 0 J H G `D B lLjl I OXX (SHOWN) XXO DOOR FRAME WIDTH 0 J C G D B I OXO (SHOWN) DOOR FRAME WIDTH A 2 w U� 0 0 0 C D B I OXXX (SHOWN) OXXO XXXX APPROVED CONFIGURATIONS 0 H rO ry 1-0 FYTFRI(lR F-YTP piny NOTE: M 0 / 1. CONFIGURATIONS SHOWN FOR ILLUSTRATION PURPOSES ONLY. FO_` W "' a 2. FOR APPLICABLE DESIGN PRESSURES AND REINFORCEMENTS Q 2 a a REQUIREMENTS SEE SHEET 5. IL 0 0 a ` m 0 3. FOR ANCHOR DETAILS SEE SHEETS 7 THRU 9. N M 0 W rl Q'O>m o 0 (L 0 03 b " Zti c,Zya,•o • • •• 0 MA •.. ••• :, ZM u F- 0,00 • • •• • •• • •, •••••• • N 0.• .; 0 J . O c0 • O V) • r •••••8 c� U) • • o V101, N p 0 ul LO Z �LL. ro 0 t\ w W O O N J I� it U �w Uw W 00 : VRODUC f REVI O us crmpl; ing Kith the FlaMm (A tort Fittg code Ameptsace No 18- otzg.13 z U m Z U m Em**09" wt-c2al lei o o C N N F FFN3pIDt �Ot11 c v a a N a n0 Z a c0'�m g o 0 0 •� oa�o 111111111//j/// O EN clq i I o N \ f e o. i0592 a m O u O U Y L p .e.� 811V71 'T1 • V M •O U YE OF ° 4��� drawing no. sheet 4 of 12 /��®, ��; 10\\\ CHART #1 DESIGN LOAD CAPACITY - PSF (GLASS) AVERAGE PANEL WIDTH INCHES DOOR FRAME HEIGHT INCHES GLASS TYPES 'B', 'B1' GLASS TYPES 'A', 'Al' WITHOUT REINF. WITH REINF. EXT.(+) INT.(-) EXT.(+) INT.(-) 30 36 42 48 54 82 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 62.2 71.1 62.2 71.1 30 36 42 48 54 84 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 62.2 71.1 62.2 71.0 30 36 42 48 54 90 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 - - 62.2 71.1 30 36 42 48 54 96 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 - - 62.2 71.1 30 36 42 48 98 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 70.0 1 80.0 70.0 80.0 30 36 42 48 102 - - 70.0 80.0 - - 70.0 80.0 - - 70.0 80.0 - - 70.0 80.0 30 36 42 48 108 - - 70.0 80.0 - - 70.0 80.0 _ - 70.0 80.0 - - 70.0 80.0 CHART #2 LOAD CAPACITY - PSF (ANCHORS) AVERAGE PANEL WIDTH INCHES DOOR FRAME HEIGHT INCHES 6 ANCHORS ATM STIIR ENDS EXT. (+) INT.(-) 30 36 42 48 54 82 162.2 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 71.1 30 36 42 48 54 84 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 62.2 71.1 30 36 42 48 54 90 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 62.2 71.1 30 36 42 48 54 96 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 62.2 71.1 30 36 42 48 98 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 30 36 42 48 102 1 70.0 80.0 70.0 80.0 70.0 80.0 70.0 80.0 30 36 42 48 108 70.0 80.0 70.0 80.0 70.0 80.0 70.0 77.9 3/16" HEAT STREN'D GLASS .090" Interlayer SentryGlas By 'Kuraray Americo, Inc.' r 3/16" HEAT STREN'D GLASS 3/16" TEMP. GLASS 3/8" AIR SPACE 3/16" HEAT STREN'D GLASS .090" Interlayer SentryGlas By 'Kuraroy America, Inc.' r 3/16" HEAT STREN'D GLASS z � �� I z W ^� 0" N 23 � � ii ii 28 � ^• � � SILICONE I ! i DOW 899 uLASS TYPE 'A' 7/16" OVERALL LAM. GLASS 3/16" HEAT STREN'D GLASS .090" Interlayer [Trosifol PVB By 'Kuraroy America, Inc.' r-3/16" HEAT STREN'D GLASS o w u \ 29 GLASS TYPE 'AI' 1" OVERALL INSUL. LAM. GLASS z �U-j z LJ Q m > In vi / 23 j I I I N n 0 / II II 28 �! �! 1 SILICONE I I /. - DOW 899 O w \ / w ALL EXTERIOR(+) LOADS SHOWN IN CHARTS ABOVE ARE FOR DOORS WITH 2-3/4" SILL HEIGHTS. FOR 2" SILL HEIGHT LIMIT EXT.(+) LOADS TO 47.0 PSF GLASS TYPE 'B' 7/16" OVERALL LAM. GLASS SILICONE DOW 899 CARDINAL XL • • • EDGE SPACER .. ST. STEEL • • 3/16" TEMP. GLASS 3/8" AIR SPACE •" 3/16" HEAT STREN'D GLASS .090" Interlayer Trosifol PVB By 'Kuraray America, ln.' �3/16" HFA7 STREN'D GLASS j ii ii \ 23 j II II 28 !I !! !! SILICONE DOW 899 Of 0 x \ \ 29 /CARDINAL XL EDGE SPACER ST. STEEL GLASS TYPE 'BI' 1" OVERALL INSUL. LAM. GLASS GLAZING OPTIONS DOORS WITH 1-1/8" SILL HEIGHTS ARE NOT APPROVED FOR PRODUCE REYtSM INTERLOCKS WITHOUT REINF. INTERLOCKS WITH REINF. WATER INFILTRATION RESISTANCE ascampWagwith tWF11efUe SEE SHEET 7 FOR DETAILS by Wing (lode NOTE: SEE CHART #1 FOR DESIGN LOAD CAPACITY OF DESIRED GLASS SIZE AND REINFORCEMENT. SEE CHART #2 FOR ANCHORS CAPACITY. LOWER VALUES FROM GLASS OR ANCHOR CHART WILL APPLY TO ENTIRE SYSTEM. Aeceptsnce No 1 -O%Z . 13 IExpi *dca Date 111 NOTE: *+e11 d GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 11 V0 U w rn Z M n o ko I M W � a 1 QIL O OWN`" LL ~ /0 V Wei p�0M --o p aca G 0 la to Nei Q W k• ji. Z - o fit W C1 le V. ••..•• U .... J J• • J00 •• • ao C • • • • • 1B W • v ��••�• o V) O �i' Q Z_ CD o � r- Z r o w O N J r� U o� ow Wa0:2Lj En V) o < o N O 0 O O a o af a w v � � a>no Zi a n of D Of =1 C p'6 o 0 �2) O O N i N N Q of o. 0592 a 'P y � O U L �= 9 N U D A OF '.��� drawing no. ®"LO ►off.-���; W 13 - 49 ol ���i®�.11;0 sheet 5 of12 1BY OR 2BY WOOD BUCKS AND METAL STRUCTURE NOT BY ECO WINDOWS MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS: SEE ELEV. FOR SPACING - AT HEAD - — — — — FTYPE 'A'- 1/4" DIA, ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) THRU 1BY OR 2BY BUCKS INTO CONCRETE 1-1 /4" MIN. EMBED INTO CONCRETE TYPE 'B'- 1/4" DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) DIRECTLY INTO CONCRETE 1-3/4" MIN. EMBED TYPE 'C'- 1 /4" DIA. SELF DRILLING SCREWS (GRADE 5 CRS) INTO MIAMI-DADE COUNTY APPROVED MULLIONS OR INTO METAL STRUCTURES (3) THREADS MIN. TO EXTEND BEYOND METAL THICKNESS ALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.) STEEL: 1/8" THK. MIN. (Fy = 36 KSI MIN.) — —(STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED)- - AT SILL - — — — FTYPE 'B'- 1/4" DIA, ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) DIRECTLY INTO CONCRETE ——1-3/4" MIN. EMBED AT JAMBS - TYPE 'A'- TYPE 'B'- TYPE 'C'- 1/4" DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1/2" MIN. PENETRATION INTO WOOD THRU 1 BY BUCKS INTO CONC. OR BLOCKS 1-1/4" MIN. EMBED INTO CONC. OR BLOCKS 1/4" DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) DIRECTLY INTO CONC. OR BLOCKS 1-1 /4" MIN. EMBED INTO CONC. OR BLOCKS 1/4" DIA. SELF DRILLING SCREWS (GRADE 5 CRS) INTO MIAMI-DADE COUNTY APPROVED MULLIONS OR INTO METAL STRUCTURES (3) THREADS MIN. TO EXTEND BEYOND METAL THICKNESS ALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.) STEEL: 1/8" THK. MIN. (Fy = 36 KSI MIN.) —(STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) — ANCHOR EDGE DISTANCES INTO CONCRETE AND BLOCKS = 2-1/2" MIN. INTO WOOD STRUCTURE = 1" MIN. INTO METAL STRUCTURE = 3/4" MIN. WOOD AT HEAD OR JAMBS SG = 0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN. C-90 HOLLOW/FILLED BLOCK AT JAMBS f'm = 2000 PSI MIN. I MROlDUC C luvism as cmptyiag with the Rites & LwWing Cede A•eeptance Ne 1S, p(Z4.13 Ezp[t'dfiaa liste�� je� *w \�11111AH 1tif►t��, �• GE•SF � e 592 JA OF Ol Vo U w d Z 01m I M M N N Q Q I ILMO ,� O 0 OWN`" i] t U. Dyh 0 9> m of�rrm8 0aco.� 0��� Q Itzs W a w. n �Zh -Wm Q W m�• F ...... o g U.... �; J J • • I 00 0 o 0 o �..... M (n W �•• x o 0(D m cn 3 N 00p 00 a Z_ � o � o Z > U-) 0 w 0 NJ W U oo Lw LLJ LEI c0 m LF, N Y u7 ,n c 2p oIn 0 N O O N drawing no. W13-49 sheet 6 of 1 '� PI 1BY OR 2BY WOOD BUCK (SEE NOTE SHEET 1) a <60NCR'ETE. n.. 3 KSI MINI c• P4 a P3 �W1, W2 METAL STRUCTURES 1 /8" THK. EDGE DIST. 3-1/8" (SEE SHEET 6) STAGGERED H TYPICAL ANCHORS SEE ELEVS. FOR SPACING LOAD BEARING SHIMS 14 OR POURED & HARDENED HIGH STRENGTH GROUT 13 NON -SHRINK, NON-METALLIC f'c = 5000 PSI MIN. _ 12 h- ci w � M = w N J e N = J_ N J N NOT APPROVED LIMIT MAX. LIMIT MAX. FOR WATER RESISTANCE EXT.(+) LOADS EXT.(+) LOADS TO 47.0 PSF TO 70.0 PSF SILL HEIGHT VS WATER RESISTANCE EXT.(+) LOAD TYPICAL ANCHORS SEE SHEET 5 CHART 1 FOR DOOR CAPACITY SEE ELEVS. FOR SPACING w rr--------------------------- ------------------------ -ice III MIAMI—DADE COUNTY APPR'D MULLION Ij � SEE SEPARATE NOA �I II (SEE SHEET ) II �j 3-1/8" I� I STAGGERED I jl — ------ --- -- TYPICAL ANCHORS SEE ELEVS. FOR SPACING WEEPHOLES: W1 = 1-1/2" LONG NOTCH AT EACH END. W2 = 3/16" X 3/4" LONG WEEP NOTCH AT 22" FROM END AND 36" O.C. W3 = 3/16" X 1" LONG WEEP NOTCH AT 5" FROM ENDS AND 36" O.C. W4 = 1 /4" X 1 " LONG WEEP NOTCH AT 5" FROM ENDS AND 36" O.C. PILE PADS: P1 = OPEN CELL FOAM AT EACH WEEP HOLE LOCATION 1-1/16" LONG X 7/16" WIDE X 7/16" HIGH P2 = SELF ADHESIVE PILE PAD 1" X 3/8" X 1/4" HIGH P3 = SELF ADHESIVE PILE PAD WITH MULTI INTEGRAL FIN 2-1/2" X 1 " X 3/8" HIGH P4 = OPEN CELL FOAM AT INTERLOCK & ASTRAGAL 2" LONG X 1-7/16" WIDE X 7/16" HIGH _ PRODUCf RET as aow4 tyiea with tilt IRiel� t umug Crude AemptaaceNo } $-6 2�i• 13 (-�!3 (� o `I v w I M Z M Or Fw M Q W � I O w N co O XaC U. O �Nh V G W ei Q'O2M o p a C o a°p O Nye m QO � J � w x •a i • �! Z LC' M (`j7 ��ii J 09 •••• ••• • • •••••• 000 ^ • Q •••• •� U .... • •J �• • • I •(10 ••• •c • W • • •0 • 00m y A • � t••••••0 • • � W v • • •Q • X C� r^•�• 0 LE z (j F- o V) S �' 3 -5 N p 00 J LOS r- o w w O NJ M W000 m LLI 2 O ° o 0 V� .N .�I®�i �° o o o. 05B2 - q�g o Y A OF .��\ drawing no. v. ®to�;.•���; W13-49 ®1A�%\sheet 7 of 12 NCHORS ING TUCK :TURE HEET 1 SHIM ""' PRODLIC f REVIS60 as emplymg Wim ce FietW Acceptsace Not 0 (2�j'. 13 EipirR:'wx Dstc ei o w I M Z ti 3 0 z co H Mm Q Q� �N I a � a a oooLLI 0 doN LU t LL v (0 m pLur, Q'0-m O 0 aap "I 0 t� N 0 N • z - •o . . .thy •••: •a W C1�•I= • ••• •• •N ••• • O :00Of 00 i • i� i%} •Lo 0 • N M • •cn W • •a • LE z F— cp o (!f cp N Q 0c) Q Z lei 000 00 O _ O Z i L0 W p w 0 NJ M � W co m � z O O r o W o ui o L W w w w V a En < a a N w a w a C O p O o 0 O O -- 'fit I N O cn o. 0592 ° a 9� O ! L T T OF �4Y�� drawing no. ®R�A�1111%,���� sheet $ of 2 OAAICI unnTW TYPICAL ANCHORS 11 -1 SHIM ! RODUC F REVOW ar CMPWM nlla 69 r ring US& Ampusec No t `6 -Q t 2-1• t 3 9u:e�i t�SeiAr'CfU�6i 1.� _ ANCHORS V. 'ACING JANTITY Vo U W d I M Z OD z M m a W Z N I IL R O ON O 0 O a " SOH � owrl >m 0 O aoo A O NN2m I ° Q W . TAL • .u• z (a= m zwml• • - •••••• r RUCTURE .... O U .... 0) • J -16 • •00 •..• • • . 00 • Q • • � M V,) LLI C7 (� • L� Z to F- (p O In N 3-. f,) C.,5 0 ") C Q Z � 00 O > 2 O to y N J M 0U LLJ 0 0w J N W ao : 0 0 U U cr O W O a a D ir =1 0 p o o F O O N O \eeee�iili���s� GEN N N s i o 70592 0 Q H •O M-j U Lai OF s�B�� drawing no. W13-49 lex\\%\ sheet g of 12 ITEM # PART # QUANTITY DESCRIPTION MATERIAL MANF./SUPPLIER/REMARKS 1 E701 1 FRAME HEAD 6005—T5 — 2 E702 1 FRAME SILL 6005—T5 — 3 E703 2 FRAME JAMB 6063—T6 — 4 E704 2/ PANEL PANEL TOP AND BOTTOM RAIL 6063—T6 — 5 E705 AS RQD. PANEL LOCK STILE 6063—T6 — 6 E706 AS READ. PANEL OUTER INTERLOCK 6063—T6 — 7 E707 AS READ. PANEL INNER INTERLOCK 6063—T6 — 8 E708 AS READ. PANEL MALE ASTRAGAL 6063—T6 — 9 E709 AS READ. PANEL FEMALE ASTRAGAL 6063—T6 — 10 E710 AS REQD. GLAZING BEAD 7/16" LAMINATED GLASS 6063—T6 — 11 E711 AS REQD. GLAZING BEAD 1" INSULATED GLASS 6063—T6 — 12 E712 AS REQD. SILL TRIM 6063—T6 OPTIONAL 13 E713 AS REQD. 2" SILL RISER 6063—T6 — 14 E714 AS REQD. 2-3/4" SILL RISER 6063—T6 — 15 E715 AS REQD. FIXED PANEL CLIP (CONTINUOUS) 6063—T6 — 17 E717 AS REQD. INTERLOCK STIFFENER (FULL PANEL LENGTH) 6063—T6 — 18 #10 X 3/4" HWH SMS AS REQD. FRAME ASSY. SCREWS ST. STEEL — 18A #10 X 1" FH SMS AS REQD. PANEL ASSY. SCREWS ST. STEEL — 19 #8 X 1/2" PH SMS 2/CLIP FIXED PANEL CLIP SCREWS ST. STEEL AT 3" FROM ENDS & 16" O.C. 20 #10 X 1-1/4" PH SMS 1/ ROLLER ROLLER INST. SCREWS — NOT SHOWN 21 WEATHERSTRIP AS REQD. FRAME AND PANEL WEATHERSTRIP — FIN SEAL .190 HIGH BY ULTRAFAB 22 E235 AS REQD. INTERLOCK BUMPER BULB SANTOPRENE ULTRAFAB 23 E203 AS REQD. GLAZING BEAD BULB SANTOPRENE ULTRAFAB, DUROMETER 65±5 24 PR03-6005 2/ MOV. PANEL TANDEM NYLON WHEELS IN ST. STEEL HOUSING — INTERLOCK (1/2" MTG. SPACER REQD.) 25 E718 2/PANEL FIXED PANEL SKATE DELRIN — 26 #8 X 1/2" PH SMS 2/CLIP FIXED PANEL SKATE INST. SCREWS ST. STEEL 27 — AS REQD. 3 PLY DUAL POINT LOCK ASSEMBLY — BY INTERLOCK 28 AS REQD. BUMPON (SILICONE SPACER) SILICONE BY FRANK LOWE 29 AS REQD. SETTING BLOCKS AT 1/4 POINTS EPDM DUROMETER 80±5 SHORE A SEALANT: ALL JOINTS AND FRAME CONNECTIONS SEALED WITH WHITE/ALUMINUM COLORED SILICONE. VMD€JC S REVISM as cmpiyiag r.qih the lu"ding Code Acceptance No i&'� �2�1 •! � Expi"time mte�jit `1 PIS CroNd V0 w 146 I o l_ r FFZ "'� a W x QI N IL �� 0 W N M O IL N 0 m v pWrl 00 m9 0 0 acorl 0 Q W&3w40 • • Z m • •• J rS,�+� • ••••• Q W Rt. F •••••• • •••• • • • •.•••• •••• •, o ••••• - ••••• U•••• � ••••- 0 • ••••• . ro • ••••. o • W •••••• • • • • x • - c� v • Z (j � co o U� (J!1 L M rn O 6M C., 00 a Z_ 00 w 0 04 N W 000 m c 2 p o 0 to t0 N d O Q m U o \�111t11111/�� ��'• c ids ®� " cy s N N Q ° s 0 \ F o 70562 m m a sf o lr __ V fo U T OF °��� drawing no. W 13 - 49 �ONY 1111 ���\\\ sheet 10 of 12 m O 5.059 078 1.312 1.998 -� 1- 1.998 FRAME HEAD l-1.144--i 5.532 .062 FRAME JAMB O FRAME SILL 1.998 1.824 1 1.648 .094 -- la- � 2.625 O PANEL LOCK STILE 1.471-1 .062 3.250 2.313 .078 Fl 1.823 OO PANEL TOP & BOTTOM RAIL -�{ .915 � b .357 149 062 J 1.540 -i 15 FIX. PANEL CLIP !2 � 3.687 3.820 140 2.000 2. O PANEL INNER INTERLOCK O PANEL OUTER INTERLOCK I - INTERLOCK STIFFENER 3.437 .078 - - 1.824 1.1 4 3.996 .078 2.500 O PANEL FEMALE ASTRAGAL I O PANEL MALE ASTRAGAL 125 8 I:= .210 )5 1.047 1.648 12 SILL TRIM VL) U W rn .1301 r �{ ,693 II m 93 .045 .93� 050 1 O 2 `��' N Q .062 � .06� � W Oo�o O 1.252 1.252 �I O W N cq � v a�W OH a GLAZING BEAD GLAZING BEAD O rn m 10 1" INSUL. LAM. GLASS 11 7/16" LAM. GLASS O no > M U' Ft m 00 0IL04 .1 .210 O Nyex .210 i •� �.Z� �o .068 • • j 5. • w ••••• Z • Q W C1 2 H .068 •.••• • 2.687 1.937 • •••••• O 1.047 1.0470 co ••�•• g J •�•� • O • M 13 2" SILL RISER 14 2-3/4" SILL RIi6fi* '(n' LL Z V) c0 o V) j t rn 0 010 U) Lo z - u- �mo "mum f R) v"aCD o z r In as aamplylag with dw Flmidv � j w „0 J to tR- a L 3Pa�tkvA" Datc�'!'c� N W co :2 �nffTFm H Z W o -W 0 W 0 N O w O L W LL) w U a Zi a O D O `\�1111111/!�e/ ` \\\AHp„ a ch la 0 2 a S F drawing no. ,0.. °�°c;� W13-49 sheet 11 of 12 18 i IaullkyjIMLei WxglaaR PANEL TOP/BOTTOM CORNER PRODUC f REVISM as caluptying TWftb tiro FWAM butdieg (Ymk Acceptance Na —01 Z . ! 3 Expiradea Hate 20 ! 18 Ley �I<k•- (- �-g4LL WAk) O W M Z MC�D� Z M N _ W Q Qa �. a OV O .j Cq IL XX W M ° t LL 0 51) 0 0 LL ei ao>mo p aca ° dJ I Nye .. � S.`"- J ...•. • z Cu s Q W C1 2 �F •••• � f N O • J • • 'n ••••• • 0 • 00 00 • • • . N v c9 (/} • LE N V� o V) 5� rn O 0n J Z OD n t` Z V) 1.1 O IY N LC) LL) w 00 m JI F �Iololo of \�111111111/l�� ��•' C�A1S�'�® /ice ^ n N � I N 7 /92Clu o w V U 7A OF drawing no. W13-49 sheet 12 of 12. THESE WINDOWS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. ECO—GUARD SERIES-60 ALUMINUM HORIZONTAL ROLLING WINDOW APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF H.R./H.R. OR HORIZONTAL ROLLING WITH OTHER WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS USING MIAMI—DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2014 (5TH EDITION)/2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON—METALLIC AND NON —COMPRESSIBLE. MATERIALS INCLUDING BUT _ NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2014/2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL _IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT. ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL. 4 1/4" MAX. HEAD/SILL CORNERS _ ~ z w rn 0 z N 0 Z j 74 1/8" WINDOW WIDTH 10 1/4" MAX. HEAD SILL A l4"� 12 I i II II 1 I II , II D _j _j -= Ir I� II LO0 J II II I I B 12 Z r 0z M j 0" Q I N Q/ Y• Opp W N U N CL K ii.r 0 - rp `0 ut 4 /V v � 0 M C Ip o. in o 4 ojJ _ NN0 Io O N �2J Q WnLL jp v, LLzN 0. oXm • •• •� 00 •Y W •• _ M Ltry • cn Co M 0 FALSE MUNTINS 33 11 /16" 33 11 /16" ¢ 2 (SURFACE APPLIED) MAY BE USED D.L.O. (VENT) D.L.O. (FIX. LITE) `O U 37 1/4" •00• VENT WIDTH TYPICAL ELEVATION MAXIMUM DESIGN LOAD RATING = + 55.0 PSF (FOR SIZES SHOWN ABOVE OR SMALLER) — 60.0 PSF 1/8" HEAT STREWD GLASS t--1/8" HEAT STREN'D GLASS .090" Interlayer 090" Interlayer Saflex Clear And Color Glass Trosifol PVB By 'Eastman Chemical Co.' �By `kuroray America, Inc.' 1/8" HEAT STREN'D GLASS \ 1 F-1/8" HEAT STREN'D GLASS o w SIUCONE oow Sss ° w NE ass NOTE: GLASS CAPACITIES ON THIS SHEET ARE z m z mBASED ON ASTM E1300-09 (3 SEC. GUSTS) 3 22 g 22 i AND FLORIDA BUILDING COMMISSION li:� DECLARATORY STATEMENT DCA05—DEC-219 (DOW i \\\\ �� .�°�U � `\ ��• W LLI 4-KS�i�al{DY•�V • R9 =`: n334'n'tS iF.::..°it :: i�'i��i � • GLASS TYPE `A' GLASS TYPE `B' As�1 % T E OF ? � L '`�;._ �/ p/��- '' R1DP`.•'�D 5/16" OVERALL LAM. GLASS 5/16" OVERALL LAM. GLASS' --__Si' �\ EVal3 �$tSw 'i T�iw>�a`-a ➢_t`{3Ei03 / "� �\ GLAZING OPTIONS �'� ® I I t I • N • p • I J ••••ono cc •• O J L • M c) Ls� • `� Ld CD t� cfl �j -C rn s�o Q O r7 2 00 I Z �� Co fn � 3' Z } O w CCD O O Q v U U) W LJ oo M w I(sheet 1 of 5 ) TYPICAL ANCHORS 1 BY SEE ELEV. METAL WOOD BUCK I FOR SPACING STRUCTURE MIAMI—DADE COUNTY APPROVED d d d ° 1d a n EDGE• DIST. MULLION & MULLION ANCHORS 4 ° ° ° °' SEE SEPARATE NOA ' a EDGE EDGE DIST. DIST. law O 19 19 17 x 1 9 TYPICAL ANCHORS LTYPICAL ANCHORS SEE ELEV. SEE ELEV. 1 li li I' li II I I I 11 I I I I I! I I! I• FOR SPACING FOR SPACING .I . I I p II i i it i! WEEPHOLES: W1 = 1/4" X 1-5/8" WEEPHOLES WITH BAFFLE AT 4" !I !! ! !! FROM EACH END AND AT MIDSPAN W2 = 1 /4" X 1 " WEEPHOLES AT 2-1/4" FROM EACH i� i! i ii ii END AND AT MIDSPAN 0 F Q W SEALANT: 0 ci i. i. it i! Li ALL JOINTS AND FRAME CONNECTIONS SEALED WITH z W ii ii I j ii JOINT SEALER. 0 19 B � i 23 3 \ • d n. e n Q. W1 v ' ' Y1 TYPICAL ANCHORS ° '.. I I SEE ELEV. W2 ° FOR SPACING a EDGE DIST. ° 703E DIST? P 1BYJ WOOD BUCK EDGE N o O V) Z n O % J a .. M 9 z m o N0000 al 6_ �(L �� .j m U LLI O �yh v) ci ui L OR In O p aao ri 0 23 t� TYPICAL ANCHORS a! � Z p N SEE ELEV. a ud m FOR SPACING Z N cc OcC5 WOOD BUCKS AND METAL STRUCTURE NOT BY ECO WDW. w ti MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM 0 • AND TRANSFER THEM TO THE BUILDING STRUCTURE. •• • • • N TYPICAL ANCHORS: SEE ELEV. FOR SPACING ..;. LO 00 1/4" DIA• TAPCON BY `ITW' (Fu=125 KSI, Fy=100 KSI) • • • • ��/�0 (n • • • j 1/4" DIA ULTRACON BY 'ELCO' (Fu-177 KSI, Fy=155 KSI) 'd M INTO 2BY WOOD BUCKS OR WOOD STRUCTURES ; Fes• w"' 1-1/2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBSr •Q��•'• THRU 1 BY BUCKS INTO CONC. OR BLOCKS a �•� 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) a :-�: .cr7 s 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) O 5� 0 DIRECTLY INTO CONCRETE OR BLOCKS � Z � 00 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) d z o 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) O N n to U ,Q w #14 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) W LLI co m uj INTO MIAMI-DADE COUNTY APPROVED MULLIONS OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS) (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE Z U m ALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.) o STEEL: 1 /8" THK. MIN. (Fy = 36 KSI MIN.) c N (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) o TYPICAL EDGE DISTANCE v a INTO CONCRETE AND MASONRY = 2-1/2" MIN. INTO WOOD STRUCTURE = 1 " MIN. INTO METAL STRUCTURE = 3/4" MIN. 6 , WOOD AT HEAD, SILL OR JAMBS SG - 0.55 MIN. .2 011 o CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN. > C-90 HOLLOW/FILLED BLOCK AT JAMBS f'm = 2000 PSI MIN. c a m `eee140111f/ff A `� � • ' ee sF • : 4 N % � o � a S, a O � L QTYPICAL"ANCHORS f EIOZ �?. ° ��� SEE ELEV. t_*;, ,.,„:;,; �•. S TEOR = ` drawing no. FOR SPACING _>y:ei �' ' •. ®RiD°���` W1 4-11 "" _M #dill\ fee\` sheet 2 of 5 ! TYPICAL ANC SEE FOR SR METAL STRUCTURE 1/4" MAX. nc OPG. EXTERIOR WINDOW WIDTH XO LAYOUT MIAMI-DADE COUNTY WINDOW WIDTH I WINDOW WIDTH 1BY WOOD BUCKS TYPICAL ANCHORS SEE ELEV. d FOR SPACING a. 1 /4" MAX. SHIM V° w Z 00 oRN Q W Q 2 N I a QI O p�o 0 OWN U a " L 0 e p 0 0 ul m XSTR O a 0 Q Q 16 O W?{Lz�.�SW 01 sew .•. • �.• — •o ... U• .... �; TYPICAL ANCHORS ' • z-{ ' 4 SEE ELEV. • FOR SPACING ' {-.•�"' x • • N r/y/'/� • • _ V• 6 • o • O o "� I W 000� w Z - LL. 00 v) o Z} i O O Q v W a�0 tpdp!!!' ��. . . GEA9S ,�® �i ro o ®. 592 - a 0 O Y A daw � TATE OF IN drawing no. OR10%•°°��; W14-1 1 sheet 3 of 5 dllil � .875 .625 2.687 .062 _.056 TYP. N1.239 To-- 2.133 - O1 FRAME HEAD .875 1.258 .625 .078 3.188 01 2.133 - FRAME SILL .062 .340 I-.996 O SILL TRACK -1.786 062, 2.357 1 .056 TYP. lv 2.448 O MOV. FRAME JAMB 050 TYP. .3241 F .384 1.203 T- .625 TYP. 625 .050 _•I .062 .769 .875 10 GLAZING BEAD O VENT TOP/BOTTOM RAIL 1.695 I(8) JAMB STILE 2.117 1.750 625 h_- -'- I TYP. 500 1.55( .8755 .t10� 1.125 O MEETING RAIL 1.719 625 062 1.061 .875 .062 J .050 TYP. 1.094 O FIXED MTG. RAIL 2.259 0 () FIXED FRAME JAMB ITEM PART # QUANTITY DESCRIPTION MATERIAL MANF./SUPPLIER/REMARKS 1 E53 1 FRAME HEAD 6063-T6 - 2 E61 1 FRAME SILL 6063-T6 - 3 E62 1 SILL TRACK INSERT 6063-T6 - 4 E52 AS READ. MOV. FRAME JAMB 6063-T6 - 5 E51 AS REQD. FIXED FRAME JAMB 6063-T6 - 6 E54 1 / VENT FIXED MTG. RAIL 6063-T6 - 7 E66 1/ VENT VENT MEETING STILE 6063-T6 - 8 E56 1/ VENT VENT JAMB STILE 6063-T6 - 9 E57 2/ VENT TOP AND BOTTOM RAIL 6063-T6 - 10 E58 AS REQD. GLAZING BEAD 6063-T6 - 12 SL203P 2/ VENT SWEEP LATCH, AT 9-1/2" FROM TOP & BOTTOM - SULLIVAN & ASSOC. 13 #8 X 5/8" 2/ iA%n LATCH INST. SCREW ST. STEEL FH SMS 14 E63 2/ VENT ROLLER HOUSING & GUIDE CELCON 15 E64 2/ VENT ROLLER BRASS - 16 E65 2/ VENT I ROLLER PIN ST. STEEL - • 17 #8 X 1" AS REOD. FRAME/VENT ASSEMBLY SCREWS CRS P.H. SMS ' 18 #8 X 3" 2/ VENT FIX. RAIL SILL SCREliVS (SILL END) CRS P.H. SMS • 19 W23181 AS REQD. PILE WITH INTEGRAL FIN W'STRIPPING - ULTRAFAB 21 E207 AS REQD. BULB SEAL SANTOPRENE ULTRAFAS, DUROMETER 65:4 22 E203 AS REQD. GLAZING BEAD BULB SANTOPRENE ULTRAFAB, DUROMETER 65"6 23 WA2L 2/ WOW. WEEP VALVE - PREFERRED ENG. PRODUCTS 24 - 1/ VENT 5/16" BOX SCREEN - OPTIONAL •�� mep _yPi�at�ra Trti �� I$ t� o w O 2 ti Q W N m as `SSO 0 Uj el S' U a " �cLa u. LLF V ONr �o'-M O 0 CL 0 'qq � G O APO NN� O WnLL z Nt O 0.5 O8,0 $ w uo W Od•[• • • • z_ in � •••••• S • fn • �• M ' w • • • • • ••••• � ice,' XQ •••••• •• M a= �•� • ly >n a3 •••••• • J VrP-- ((O Q 3 s; C O o� C W W O J IA Z co cmc r, ocn O cV -1u ca o w 00 U uw W W 65 m L Pi1 Iisheet 4 of 5 1 i i VENT TOP/BOTTOM CORNERS FRAME BOTTOM CORNER 17 A ,_Ywa ol Dare.olx a4 W • ••• • N ! • p OD 00 J CD • v • " • FL- w LL , Lam' V• rn O ;5 n 4J p c i to W Z L � V) 3 Zr w o Ooov W W ago FIXED MTG. RAIL CORNER •••••• • • • • • ..... ..•• ...... ••••• • •••• SERIES 6aQ.... •;•••• Ah• JMINUM••O"I'SWING ENTRANCE DOOR •:.••• SINGLE SX) A;Q•DOVBLE (XX) LEAF DOORS SEE SHEET 2. SWf49 •jLONE SINGLE SIDELITE SEE SHEET 3. , SINGLE AND DOUBLE LEAF DOORS WITH SIDELITES SEE SHEET 3. LOWER VALUES FROM SIDELITE CAPACITY CHART OR DOOR CAPACITY WILL APPLY TO ENTIRE SYSTEM. DOORS APPROVED FOR INSTALLATIONS WHERE WATER INFILTRATION RESISTANCE IS REQUIRED. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON -COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL. 1/8" HEAT STREN'D. GLASS .090" Interlayer Trosifol PVB By 'Kuraray America, Inc.' 1/8" HEAT STREN'D. GLASS SILICONE DOWSIL 899 Z 3/16" HEAT STREN'D. GLASS .090" Interlayer Trosifol PVB By 'Kuraray America, Inc.' 3/16" HEAT STREN'D. GLASS SILICONE DOWSIL 899 0 \ 0 \ / w \ _ GLASS TYPE 'G1' M V) 3 0 rn GLASS TYPE 'G2' 1/8" TEMP. GLASS ,5/16" AIR SPACE 1/8" HEAT STREN'D. GLASS .090" Interlayer Saflex Clear And Color Glass By 'Eastman Chemical Co.' 1/8" HEAT STREN'D. GLASS SILICONE DOWSIL 899 � I oLLJ \ / x \ w GLASS TYPE 'G3' THESE DOORS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. SETTING BLOCKS AT LAM. GLASS READ. FOR WIDTHS EXCEEDING 36" ONLY NOTCH GLAZING BEAD LEG TO CLEAR BLOCKS CARDINAL XL EDGE SPACER ST. STEEL SILICONE SETTING BLOCKS AT INSUL. LAM. GLASS NOTCH GLAZING BEAD LEG TO CLEAR BLOCKS PRoDuc r AEVLWA " complyt&; wit' the F-id. buiding Cede AoceptsaceNe 1 za31y./3 Expfrte0ote [Bete M__!%1.2e�, ?il'j li�w9 �iF!•�y [sii�ot 111191Plg�0 � s '1R .70592 -MA iA E 0P �9�\ � 00 `� �� is jlb Nl�l�,\\v o w w OD I N z 3 0 �� Q w w z I 42 N a o_ �: O- p�0 O N CL LL v�N~ owe 0' 0 M o 0 CL 0 /0�yy t � ti N N O N Q w O tL U) w N . 0 i O � O t0 Q w 0 rL ~ .. N U m J L0 o` J ,n o ao Coao 0 w V N z � o Ld Hw x w w o } �(C) 3 Cf) �O N 3 p 0 O� u') 0 LO Q Z Co 00 o z> o NJ W LSJ ao : [sheet 1 'of 9 ) o U 39 3/4" MAX. 76" MAX. 37 3/16' MAX. o FRAME WIDTH FRAME WIDTH FRAME WIDTH I ^� aD HEAD & SILL ANCHORS 0 ,", o� AT STILE ENDS — z z 12" (4) AT 3" O.C. 12" 12" H W a 5" MAX. MAX. 5" MAX. MAX. 5" MAX. MAX. Q JL N M HEAD / - HEAD HEAD O p ` p o HEAD/SILL A SILL HEAD/SILL A SILL HEAD/SILL F SILL D 0 N 0 U CORNERS CORNERS �� �� CORNERS ILN O~ L6 _I I� V N m a FoFp rl 0 °� W ----I1 - \ ----IL---- to IA O N ----Ir/--- \ ----It---- W z J LOCK OPTIONS / E LOCK OPTIONS j j J (9 0Q j #1 OR #2 / II #1 OR #2 \ F H Q W 0 F (OPTION 2 SHOWN) _ _ _ I _ _ _ _ (OPTION 2 SHOW --- SEE SHEET 7.1---*---- SEE SHEET 7.1 w -----Icy----- FOR DESCRIPTION / yl FOR DESCRIPTIOt�i xx N X w fl xQ N = N w w 2 II' �m < a �m O � (0 Li (o w 0) Lj` O '� N m w J t J v) < ¢ m m-_-----11---- �� O O-----IL----- C) amo x Q (n---rr---- w--,r----- o m m \ II / (n w II w in • • • � � II F II z � M • • \ II / II Q w •LLJ II II w W �(D • II \ / N • • • II \ / II � � O � • • CD • •••• /CB /CB \ / 00 • • J ••••• Q ? W J • • • \ 1 1 O Z r O • INACTIVE ACTIVE w to N J N) • •••• •••••• N N N Q O p SIIR•F�, APPLIED• • • m Z SURFACE APPLIED Z SURFACE APPLIED Z N W o0 • FA TINS OF2 26 15/16" < FALSE MUNTINS OR 26 15/16" 26 15/16" < m FALSE MUNTINS OR 32 3/4" < LSD M� DECORATIVE GRILL D.L. OPG. (O o0 DECORATIVE GRILL D.L. OPG. D.L. OPG. fO �v DECORATIVE GRILL D.L. OPG. `O MAY BE USED MAY BE USED MAY BE USED 37" MAX. 37" MAX. LEAF WIDTH LEAF WIDTH W . z u L m m 2 o�oN C N N STAND ALONE SINGLE SIDELITE a o ir o w SEE SHEET 3 FOR CAPACITY ` w W W o z U w = a < a < c aNi Z a a O cr Z) � D z 5 t3DUC i RE�+IIWO r� ex�a"az�rt(r�i"o�g with the a�idt bwmng �@ O N 0 AoceptAnce No �- O 3 / 0 q 000�0 10 spirstioa DateZp� (5 ? c < m GLASS D.L.O. DIMS. :l Cfr cut" �`�`\��D AH4 f D.L.O. HEIGHT = FRAME HEIGHT - 1 1.125° �,eO�NSg ......... • it D.L.O. WIDTH (X DOORS) = FRAME WIDTH - 12.813" N D.L.O. WIDTH (XX DOORS) _ (FRAME WIDTH - 22.125")/2 = o; 0592 _ Viz` o NOTE: ''nn : �\ GLASS CAPACITIES ON THIS SHEET ARE ®gyp ' TE d���® drawing no. NOTE: BASED ON ASTM E1300-09 (3 SEC. GUSTS) ®� °° �"1 e R1D�.•°°moo W12-08 EGRESS REQUIREMENTS TO BE REVIEWED AND FLORIDA BUILDING COMMISSION �>i � ��` BY BUILDING OFFICIAL. DECLARATORY STATEMENT DCA05—DEC-219 °°0®/� 1111 I\ �` sheet 2 of g I I II II / II I II E / 11 / II II O � C� III _ ^ a O II�/ w � II \ II \ II II • • • \ II • II • • • • • II \ II •••••• ACTIVE DOORS LOAD CAPACITY - PSF SINGLE DOORS (X) DOOR DIMS. LAMINATED GLASS FRAME WIDTH LEAF WIDTH FRAME HEIGHT EXT.(+) INT.(-) 39-3/4" 37" 98" 70.0 75.0 DOORS LOAD CAPACITY - PSF DOUBLE (XX) DOOR DIMS. LAMINATED GLASS FRAME LEAF FRAME EXT.(+) INT.(-) WIDTH WIDTH HEIGHT 76" 37" 98" 70.0 75.0 DESIGN LOAD CAPACITY - PSF STAND ALONE SINGLE SIDELITES SIDELITE FRAME WIDTH INCHES SIDELITE FRAME HEIGHT INCHES WITHOUT REINFORCING EXT.(+) INT.(-) 24 30 36 37 42 82 1 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 61.7 1 66.1 24 30 36 37 42 86 1 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 61.7 66.1 24 30 36 37 92 70.0 75.0 69.8 69.8 64.1 64.1 63.3 63.3 24 30 36 37 1 98 63.3 63.3 57.8 57.8 53.1 53.1 52.4 52.4 . • • 000000 iL •••• •••••• • • •SINGLE STD,ELITE:WIDTH GLASS D.L.O. DIMS. D.L.O. HEIGHT (SIDELITE) D.L.O. WIDTH (SIDELITE) DESIGN LOAD CAPACITY - PSF SIDELITES WITH SINGLE OR DOUBLE LEAF DOORS (SEE NOTE BELOW) SIDELITE FRAME WIDTH INCHES SIDELITE FRAME HEIGHT INCHES WITHOUT REINFORCING WITH REINFORCING EXT.(+) INT.(-) EXT.(+) INT.(-) 24 30 36 37 42 82 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 61.7 66.1 61.7 66.1 24 30 36 37 42 86 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 70.0 75.0 61.7 66.1 61.7 66.1 24 30 36 37 92 70.0 75.0 70.0 75.0 69.8 69.8 70.0 75.0 64.1 64.1 70.0 75.0 63.3 63.3 70.0 75.0 24 30 36 37 98 63.3 63.3 70.0 75.0 57.8 57.8 70.0 75.0 53.1 53.1 70.0 75.0 52.4 52.4 70.0 75.0 REINFORCING AS READ. SEE CHART 39-3/4" MAX. (SINGLE) SIDELITE WIDTH �}I 76" MAX. (DOUBLE) DOOR FRAME WIDTH NOTE: FOR DOORS CAPACITIES SEE SHEET 2. FOR SIDELITE CAPACITIES SEE CHART ABOVE. LOWER VALUES FROM DOOR OR SIDELITE CHART WILL APPLY TO ENTIRE SYSTEM. FRAME HEIGHT - 11.000" FRAME WIDTH - 4.438" 5" MAX. HEAD/SILL CORNERS 148" MAX. TESTED FRAME WIDTH HEAD & SILL ANCHORS AT STILE ENDS CLUSTER OF (4) AT 3" O.C. g" (4) ANCHORS AT HEAD/SILL 12" 3" MAX. QTYP. HEAD F /(A SILL - ' I I II I I I I I II I I 0o 00 a rr) i// n O \ (O L� / / (O J / m m o \-----p----- I I / \ II LOKOP;(1OS 1 OR/#2 \ I (0 TJ.ON 1 S 0 ) \ i SE SHEET .1 \ I I FQ DESCRIPTION I I ` I \I I I INACTIVE ACTIVE SURFACE APPLIED_// 32 3/4" 26 15/16" 26 15/16" FALSE MUNTINS OR DECORATIVE GRILL D.L. OPG. D.L. OPG. D.L. OPG. MAY BE USED 37" LEAF WIDTH SIDELITE FRAME WIDTH 39 3/4" MAX. (SINGLE) MAX. 76" MAX. (DOUBLE) SEE CHART AT LEFT DOOR FRAME WIDTH (OXXO) MAX. UNIT TESTED FRAME AREA NOT TO EXCEED 100.72 SQ. FT. PER FBC 2014 NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 ORODU f REVIW as co-piyiag with the Flwidz buidiog Cade Aoceptsuce No Etpirad" it l q 6 \®11i11I91ptte' CENS NO.70592 I 5 lT' OF a OIL 0?, C. o U w m O I N Z M O j C z m (` C"c a W a a OO�V O Ln O 0 N m U 0 H LL 0VNm V p ui ri It 0 IL 0 03 L O Q W D ILL W N - O Z M Q w uI CD f r ^ N J �' J .1 o 00 w Ln z � v LEI cl P W z }w w ca F- � 3 CO� N 3 - rn ~ + M N =o O O M u� J Ln Q Z ao 0 3 z >- LJ o cn J W 0 00 W W o0 (sheet 3 of 9 J 9/16" MIN. THROW BOLT PENETRATION L u 0 1/2" MIN. THROW BOLT PENETRATION TYPICAL ANCHORS SEE ELEVATIONS FOR SPACING w a V) l� I I I I I I I I I I I I I I I I I GLAZING OPTIONS SEE SHEET 1 I I I I I I I I I I I I I I I I I I J ° Y v TYPICAL ANCHORS EDGE DIST. SEE ELEVATIONS FOR SPACING EDGE DIST. Q e v a ad as O cr w X w PROPERLY SECURED 1BY WOOD BUCK EDGE DIST. TYPICAL ANCHORS SEE ELEVATIONS FOR SPACING 2BY WOOD BUCK OR WOOD STRUCTURE SEE NOTE SHEET 1 EDGE a 0)� / 4 0- p N O W w x \ _ w 0 w TYPICAL ANCHORS SEE ELEVATIONS FOR SPACING 1BY OR 2BY WOOD BUCKS AND METAL STRUCTURE NOT BY ECO WINDOWS MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS: SEE ELEV. FOR SPACING 1/4" DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-1 /2" MIN. PENETRATION INTO WOOD (HEAD/JAMBS) THRU 1 BY BUCKS INTO CONC. OR BLOCKS 1-1 /4" MIN. EMBED INTO CONCRETE (HEAD/JAMBS) 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) DIRECTLY INTO CONCRETE OR BLOCKS 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1 /4" MIN. EMBED INTO BLOCKS (JAMBS) #14 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) INTO MIAMI-DADE COUNTY APPROVED MULLIONS OR INTO METAL STRUCTURES (HEAD/JAMBS) (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE ALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.) STEEL: 1 /8" THK. MIN. (Fy = 36 KSI MIN.) (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) TYPICAL EDGE DISTANCE INTO CONCRETE AND MASONRY = 2-1/2" MIN. INTO WOOD STRUCTURE = 1" MIN. INTO METAL STRUCTURE = 3/4" MIN. WOOD AT HEAD OR JAMBS SG = 0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN. C-90 HOLLOW/FILLED BLOCK AT JAMBS f'm = 2000 PSI MIN. METAL EDGE DIST. F STRUCTURE w � a N (N TYPICAL ANCHORS SEE ELEVATIONS FOR SPACING r-------------------� j I MIAMI-DADE COUNTY APPROVED I 1 I CLIPPED MULLION I I I SEE SEPARATE N A I I II II L----------------J I — J TYPICAL ANCHORS SEE ELEVATIONS FOR SPACING oA.OffUC f BEVIS" as cGyptyiag with the Fw" A,Ctpl c� � .13 A�ptaaceNo `�� Ew atiw pmtc: ,. Q DOOR DETAILS ®`11111119///// IGE i� � . s 0.70592 _ MO ,1 1Q1� TE OFRID I f" V O U w QD 0 I N Z M 0 z col a Q 2 Z a W N ` p O 0 a N U. 0 Vyh ciCWvi 0 yy� to Q W z O N Z (1)- o 02 M ZMa uw W M f h N U o J ul v' J Lr) 00 000 0 U Z Ld .M. H w X w N W CD } I- (o V) ~ -r- N m 0 00_j QZ_ 3� LL. o 0 3 zr o c0 J M cn O pN 0 LLJ V U-)w w N w 05: (sheet 4 of 9 ) 1 /4" MAX. SHIM r (�) TYPICAL ANCHORS SEE ELEV. FOR SPACING METAL STRUCTURE SEE SPEC SHEET 4 1 /4" MAX. SHIM a TYF?1CAL.:ACHORSS SEE ELEV'?' • FOR.SPACING • • • d s , . .w •w . • • d CONCEALED FLUSH BOLTS LEVERS AT STILE FACE ACTIVE LEAF EXTERIOR D. L.O. 37" MAX. LEAF WIDTH 39 3/4" MAX. SINGLE DOOR FRAME WIDTH 2 POINT LOCK ASSEMBLY INACTIVE LEAF EXTERIOR L O 1 /4" MAX. SHIM 1BY /, WOOD BUCK v. o F PLn TYPICAL ANCHORS SEE ELEV. FOR SPACING C] w • o v LOCK OPTIONS #1 OR #2 (OPTION 2 SHOWN) SEE SHEET 7.1 FOR DESCRIPTION 4 POINT LOCK ASSEMBLY ACTIVE LEAF DOOR DETAILS PRODUCtREWWO = complying wilt the i"i " (snldins Credo &�, Aaecptssce No `1 igF�i �' YCt +CMIl9i 1 /4" MAX. I PHIM 0 TYPICAL ANCHORS SEE ELEV. FOR SPACING :tc0 U w 0 0 1:11 I N Z M 0 3 0 F ItS 0 / �Z 6'N Q W I N C O O W 0 t� U 0 v(1)� V paid IL � 0 0 aN� a° M Z - j N Q W W III - 0 —02 Z M Q W Q W o� � ►- N J LO � J Ln o 00 U � O z � M Hw X w V) W CD } O � 0 (0 ~ > �M N C) 0 � Ln 00J LO a Z 3� u- ro 0 3zra w W O 00 Of u) w w LLJ N W ao z W W m U N U O N 0- ~ W 0 F a w 0 Qf o K z K U U a = a w ¢ N t' o a 0 0� z cr > 6 N _O 0 N N 6 O N 0 0 0 F o 0 0 �11111at��® ° ® O M ~ Rfio. 70592 "M)AR 201 N e-)U1 Itf T kT OF drawing no. \12 � %\ \�\\ sheet 5 of 9 TYPICAL ANCHORS 0 'TIONS 1 f n )RS S FOR SPACING 1 /4" MAX. SHIM TYPICAL ANCHORS SEE ELEV. FOR SPACING s w 0 0 w METAL STRUCTURE SEE SPEC SHEET 4 1 /4" MAX. SHIM 92, 9 " TYPICAL ANCHORS SEE ELEV. >w FOR SPACING O O EXTERIOR D.L.O. 42" AT 86" HT. 37" AT 98" HT. MAX. SINGLE SIDELITE WIDTH #12 SMS AT 5" FROM ENDS AND 1 1 " O.C. MAX. D.L.O. _ EXTERIOR 1 /4" MAX. SHIM 1BY . WOOD BUCK ° v° TYPICAL ANCHORS ° SEE ELEV. FOR SPACING UJ 0 0 REINFORCING IO18 AS REQD. SEE SHEET 3 I I I I I I I I � f LEAF WIDTH 39 3/4" (SINGLE) 76" (DOUBLE) MAX. DOOR FRAME WIDTH MAX. UNIT FRAME WIDTH ORODUC f RMSM as camplyimg with the b' orkk btuding Cry Aaccptance No 1 Q 3l I rE.gks Iliyr�`. !1'rty' spa lU�1K'1 CAaflFli SIDELITE DETAILS D.L.O. '�0. 7®g9a tlE OF O U w 0 0 I N ^ OD 0 z r- H Q W Q ? N CL a 0 W NLu ` M O C ~ LL 0 UNh V p ui ri 0p O '- M 0 0 aco r 0 oiaF O Q W D LL N W y _. 0 Z02'" � co Lul uMf� I- N o J 0) v J L0 J ,1 o 000 0 U 0 a LtJ cy—w X i? (n W �a+ z (/� U j � 3 (.0 rn 3 n N o p o �� 00_j LO a Z �� w c. J M cn O pp 0 U ,n w w Li1 co : w 1:5 z w g m 0 O N OU O ¢ Q 0 a:~ W N a w 0 2 c� w ¢ w o Q U a = a U p m x O d W x Z O � N 7 2 r 00 C°).�Nm� 0 0 N o 0 0 N O Q - U- W L 0 N O N \ a O M drawing no. W12-08 r, o �P W w o 0 I N -� ao 0 H n Z M N Q W y I N a D: O0`0 O o . _. N lr U �� W �yh of0�m o 0 dGQ o'p /0/yy yNF 0 ii 0 Z 0 N Q wz wy o zo2'" 0 c0 Q W 0 11-- r. N U J 0) J ul ckf J 0 000 0 w U � O 000000 Z w • • •• . •• (^ j x • • • . w N w if • • • • } •••••• • • • • • FLO - z � �� • • • • • •• •• 0 0 M N • .00. • • '� as • •••• •••••• • • • •••• } • o ZW 0 • • •••••• (D M • •••• •••••• V) 00 0 w U Lnw •••• • •• w W 00 g • • • • �" •••••• • co w U w U C m m m = p O n N ¢ O U O S O w N w N r a O a O w U L w Ow w Ow ¢ U a a _ N ¢ ¢ U N a a o SEALANTS: � _ ' ' Z ALL JOINTS AND FRAME CONNECTIONS SEALED WITH SCHNEE MOREHEAD JM5504 SEALANT. N `° C O N N 0 h 2 O N 0 0 0 (n t0 t0 Oi � Ih •) O O O — O C DRODUCfIkEYfs P ���\\��..��\.GN��,��ii N Be emptying with the " �� � 4imtdsng Cede e e o a kceeptaace No /� o ? i�i . 13 ����2 M Ebpirsdoe Date dal _ 20� o • T s 6 O U t O � • ♦ Lit � s / o � N N�-�' N�dr Proitact Ceal�oi E OF 2�e drawing no. ✓ess,'���►�I I l i a \� ��``�` sheet 7 'of g ITEM # PART # REQD. DESCRIPTION MATERIAL MANF./SUPPLIER/REMARKS 1 E601 - DOOR FRAME HEAD/SILL 6063-T6 - 2 E602 - FRAME COVER 6063-T6 - 3 E603 - DOOR FRAME JAMB 6063-T6 - 4 E604 - SIDELITE TOP &BOTTOM FRAME 6063-T6 - 4A E626 - SIDELITE 9" BOTTOM FRAME 6063-T6 - 5 E605 - SIDELITE FRAME JAMB 6063-T6 - 6 E606 - SIDELITE SLIP ON JAMB 6063-T6 - 7 E607 - LEAF TOP &BOTTOM RAIL 6063-T6 - 7A E625 - LEAF 9" BOTTOM RAIL 6063-T6 - 8 E608 - LEAF W'STRIP ADAPTER 6063-T6 - 9 E609 - LEAF HINGE STILE 6063-T6 - 10 E610 - LEAF LOCK STILE 6063-T6 - 11 E611 - LEAF ASTRAGAL STILE 6063-T6 - 12 E612 - LEAF ALIGNMENT BRACKET 6063-T6 - 13 E613 - LEAF CLAMP 6063-T6 4-1/4" LONG 13A E613 - HINGE BACK-UP PLATE 6063-T6 12" LONG 14 E614 - GLAZING BEAD (5/16" LAM. GLASS) 6063-T6 - 14A E109 - GLAZING BEAD (7/16" LAM. GLASS) 6063-T6 - 15 E615 - GLAZING BEAD (INSUL. GLASS) 6063-T6 - 16 E616 - SNAP COVER 6063-T6 - 17 E613 - BOLT SUPPORT 6063-T6 NOT SHOWN 18 - AS READ. SIDELITE MULLION REINFORCING 6063-T6 - 19 FD-107 3/ LEAF BUTT HINGES ALUMINUM SULLIVAN & ASSOC. 20 F61202 - FLUSH BOLT LEVER - SULLIVAN & ASSOC. 21 FBR914SS - CONCEALED FLUSH BOLT ROD ST STEEL SULLIVAN & ASSOC. 22 #12 SMS AS REQD. FRAME ASSEMBLY SCREWS - - 23 #12 X 3/4" - HINGE INSTALLATION FASTENERS - FH SMS 24 - - 3/8" DIA. THREADED ROD STEEL - 25 W11323 - PILE W'STRIPPING WOOL ULTRAFAB 26 E20618-KN-3020 - BULB W'STRIPPING SANTOPRENE EPDM 27 E206 - GLAZING BEAD BULB SANTOPRENE ULTRAfAB 28 - - GLASS SPACER SILICONE FRANK LOWE RUBBER CO. 29 E622 - FLUSH BOLT CUP NYLON - 30 pL01RC - BLACK BOLT SUPPORT BLOCK POLYETHYLENE INTERLOCK 31 DLOIWB - WHITE BOLT SUPPORT BLOCK POLYETHYLENE ACME PLASTIC 33 #10 X 3/4" 2/ ADAPTER FH SELF DRILLING SCREWS - - 34 - 2/ LITE SETTING BLOCK, 1/4" X 1/2" X 4" LONG EPDM AT 6" FROM EACH END, DUROMETER 80t5 35 - 2/ LITE SETTING BLOCK, 1/4" X 3/4" X 4" LONG EPDM AT 6" FROM EACH END, DUROMETER 80t5 LOCKS: OPTION #1: ACTIVE LEAF: 4 POINT LOCK ASSEMBLY DL01-6007 BY 'INTERLOCK USA INC.' (2) LOCKING POINTS ENGAGING AT INACTIVE LEAF AT STRIKE PLATE 1/2" DIA. THROW BOLT (1) AT TOP ENGAGING FRAME HEAD AND (1) AT BOTOOM ENGAGING FRAME SILL THROW BOLTS ATTACHED TO LOCK BY 3/8" CONNECTING RODS LOCK HANDLE LOCATED AT 42-1/2" FROM BOTTOM INACTIVE LEAF: 2 POINT LOCK ASSEMBLY BY 'INTERLOCK USA INC.' 1/2" DIA. THROW BOLTS AT TOP AND BOTTOM ENGAGING FRAME HEAD AND FRAME SILL THROW BOLTS ATTACHED TO LOCK BY 3/8" CONNECTING RODS LOCK LOCATED AT 42-1/2" FROM BOTTOM / I I / I I / I / I I • .I ••..� •`k•• • • • • • ACTIVE I HINGES: I I I I � I I I I I I I I INACTIVE ACTIVE 3-1/2" X 7-5/8" X .122" THK. EXTRUDED ALUM HINGE PART #FD-107 BY SULLIVAN & ASSOC. 3 HINGES PER LEAF BOTTOM HINGE AT 10-1/4" FROM BOTTOM TOP HINGE AT 11-3/4" FROM TOP CENTER HINGE AT MIDSPAN (38" O.C. MAX.) HINGES FASTENED WITH #10 X 1" FH SMS (5) SCREWS AT HINGE STILE (6) SCREWS AT FRAME JAMB O U w aI OPTION #2: o N ACTIVE LEAF: -� 0 CONVENTIONAL DOOR LOCKSET WITH HANDLE o f, h DELTA 690 BY 'KWIKSET' LOCATED AT 39-1/4" FROM BOTTOM w c' env za KEY OPERATED ON EXTERIOR AND THUMB TURN ON a g cf0v 1 INTERIOR THROW BOLT LOCATED AT 44-3/4" FROM BOTTOM IL O0`� O CONCEALED FLUSH BOLTS BY 'SULLIVAN & ASSOC.' C W N 1/2" X 2" THROW BOLTS ENGAGING FRAME AT HEAD AND SILL H U. MANUALLY OPERATED LEVERS MOUNTED ON STILE FACE LOCATED AT 10-5/8" FROM TOP AND BOTTOM V N r LOCK FASTENED Td STILE WITH (2) #8-32 X 1/2" FH MS O > M C o INACTIVE LEAF: - < Q a00 CONCEALED FLUSH BOLTS BY 'SULLIVAN & ASSOC.' 1/2" X 2" THROW BOLTS ENGAGING FRAME AT HEAD AND SILL O dJ U) N O co MANUALLY OPERATED LEVERS MOUNTED ON INSIDE FACE Q W U. OF LEAF STILE LOCATED AT 10-5/8" FROM TOP AND BOTTOM {� Z N = LOCK FASTENED TO STILE WITH (2) #8-32 X 1/2" FH MS J tS t0 Q W 01 F I / / \ Q ACTIVE II INACTIVE ACTIVE J J N 0' ckf O J rn 00 000 LdOf ~ M Z W W W w Z � (0 N O M p 0 "� 01 N N Q 0 00 Z LL- OD �o Z c0 J O 00 0 rM w (IfU L,, �w LLJ oo : w 21 H V) W U W r- U J Mm m 2 p a O ^ v N F ORODUC t RE[19M O oN O w as complying with the Fioiir w o w o z finding Code Acceptance No . (� N 0 0 Z -IL-6 Et AMden Date �LC1 D D G, 477 .2 p N o 0 0 7 0 0 0 o �®1111E101///0, Qua'''% ENCN S� f I co a °92 — T � � CI A 2018. � d D O Y e ) e O V L ®�0� ° T OF Lq2 a Ksheeti�7glof ;no;.ORI �10NQL �`� //►IE1111 "Wa 62 1.625 .078 4.031 {� 2.062 DOOR FRAME HEAD/SILL 4.000 1.625 4.781 .078 • .• .. 1.750 •SIDE IITE•TOP &*BaT.TOM FRAME • • • ���•�� 329 • • *J ••••.• • 1.812 FRAME COVER �{ .687 .050 11 97 II� 154 SNAP COVER 1.750 1.750 4.750 1.507 LEAF TOP/BOTTOM RAIL LEAF HINGE STILE 1.507 5.344 4.000 1.750 2.081 1.507 .078 LEAF LOCK STILE 5.344 F.078 1.750 2.081 1.50� F= - 4.000 ------i tt LEAF ASTRAGAL STILE .625 1.500 j r 1.500 --.719 .078 4.000 � 4.000 .078 2.097 1.507 DOOR FRAME JAMB SIDELITE FRAME JAMB 8. .519 .803 .045 1.047 to GLAZING BEAD 5/16" GLASS 7.; 4A l -�{050 �� .394 80L3�--�{� ., 1.047 14A GLAZING BEAD 7/16" GLASS 9" BOTTOM RAIL SIDELITE 9" BOTTOM FRAME I r.130 .803 .045 -1.172 15 GLAZING BEAD INSUL. GLASS 50 � 1.500 �.312 .062 LEAF W'STRIP ADAPTER 094 .312 .442 4 1.584 12 LEAF ALIGNMENT BRACKET I{ 375 I 1.574 .125 9� 13 LEAF CLAMP 10 HINGE BACK-UP PLATE 4.188 1.250 078 719 SIDELITE SLIP ON JAMB �{.750� 281 125 3.781 18 SIDELITE MULLION REINFORCING PtODUC r REviSM Is mmplyiae with the Flerw bolding Code Aoceptsace Not _ aL KtOruim u4tc--31 I� o U :f0W 00 ' I N C Z 00 i M N Q W 1 m N 0. Qa m - O p � 0 o J N XX 0Uyn O�52:m o 0 IL 0 � 0 Nym 0 Q W n LL Z y m 0(0Q j a W 0) F � N J °' cl:: .J ,1 o ro 0 C.5 CD a LJ z w W U)w } fif �D z (n V) cD 3 rn F 3-�N =o O 0uO �00J aZ 3 w oOoo 0 3 Z> o cn lV J N w t� � Vow w w Lv ao � F U) L L L U LW W W m W m x m - x (n N (n ^ N D Ln D o Z Z Z r Z 0 W U U U Q U 0 0 0 a 0 z z z D z 6 N N N 0 O Ili N O � O N 0 0 0 ee�tataou�e�®®� 0 a T 0 N \ r 70592 o III I�� ARj i�018 °°W; cl �//2 drawing no. sheet 8 of 9 • J • • •• • WVr\ rf\/11VIL l�Vl\IVLI\ • • • .. 000000 ••••.• • • • •••••• • •••• •••••• •••• • •• • LEAF CORNER SIDELITE FRAME CORNER 22 SIDELITE MULLION SLIP ON JAMB CORNER o 22 U W 00 0 N c r / O Z M N Q F W � N Q Q d 0 0 o / N O Oti ci o W .� Opaco 0 �c Q W O W LL W (n a zO2 R Z M a W Q W m t- ck: J 6 00 OO 0 U)CD Goo N W Of Z U) w W `r U° ''^^ VI N ~ 0 M 0 0 "' I04 P ) 0 aJ J ZZ LL 1 00 Qo z r O O04 J LLaJ O M W W O W J Fw- (n w lmi = 0 vx) M ^ v U V UO N C < N *ROflUC C REEMS a o w 0 to ousnptyiQQ wit4 the Red& c W< W W a beuiing Coto cJ a x n x m U QO U Acceptance No I if'd 1 3 °' Z z E6�'iI'titiiR6 [M►te MAo �ZO (� 'r[i iiRs 0 a C0 N N m N p 0 O O f/) to w m � n ' O O o O LJ o Q m U W `oe�(��o�eaetMrioii �•°ENa _ w 1 i I 00 .70592 — M O U Y Si) E OF drawing no. s� i/j®I lilt (sheet,����\ 9 of g MecaWind Std v2.2.7.7 per ASCE 7-10 Developed by MECA Enterprises, Inc. Copyright www.mecaenterprises.com Date : 9/11/2018 Project No. JobNo Company Name : E.M.MORA ARCH Designed By Architect Address : 8752 SW 143 ST Description Wind Load Calculation City : Palmetto Bay Customer Name Tracy Young/Rem Elizabeth State : F1, 33176 Proj Location : 990 Ne 97 St, Miami Shores, F1< 33138 File Location: C:\Users\marco\AppData\Roaming\MecaWind\Default.wnd Input Parameters: Directional Procedure All Heights Building (Ch 27 Part 1) Basic Wind Speed(V) = 175.00 mph Structural Category = III Exposure Category = C Natural Frequency = N/A Flexible Structure = No Importance Factor = 1.00 Rd Directional Factor = 0.85 Alpha = 9.50 Zg = 900.00 ft At = 0.11 Bt = 1.00 Am = 0.15 Bm = 0.65 Cc = 0.20 1 = 500.00 ft Epsilon = 0.20 Zmin = 15.00 ft Pitch of Roof = 2.62 : 12 Slope of Roof(Theta) = 12.32 Deg h: Mean Roof Ht - 13.97 ft Type of Roof GABLED RHt: Ridge Ht = 17.24 ft Eht: Eave Height = 10.69 ft OH: Roof Overhang at Eave= 2.50 ft Overhead Type = OH w/ soffit Bldg Length Along Ridge = 82.90 ft Bldg Width Across Ridge= 55.00 ft Gust Factor Calculations Gust Factor Category I Rigid Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq.>l Hz) use 0.85 = 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm: 0.6*Ht = 15.00 ft lzm: Cc*(33/Zm)^0.167 = 0.23 Lzm: 1*(Zm/33)^Epsilon = 427.06 ft Q: (1/(1+0.63*((B+Ht)/Lzm)^0.63))^0.5 = 0.91 Gust2: 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm)) = 0.88 Gust Factor Summary Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85 Table 26.11-1 Internal Pressure Coefficients for Buildings, GCpi GCPi : Internal Pressure Coefficient = +/-0.18 Wind Pressurs Main Wind Force Resisting System (MWFRS) - Ref Figure 27.4-1 q • • • • • • • • • • • • • • Kh: 2.01*(Ht/Zg)^(2/Alpha) = 0.85 ••• • • • • ••• • • . ..... . ... . ...... . .... .... . . .... . Kht: Topographic Factor (Figure 6-4) Qh: .00256*(V)^2*I*Kh*Kht*Kd Cpww: Windward Wall Cp(Ref Fig 6-6) Roof Area Reduction Factor based on Roof Area = 1.00 = 33.94 psf 0.80 5091.17 ft^2 = 0.80 MWFRS-Wall Pressures for Wind Normal to 82.9 £t Wall (Normal to Ridge) All pressures shown are based upon ASD Design, with a Load Factor of .6 'Wall Cp Pressure Pressure +GCpi (psf) -GCpi (psf) --------------- ------ ----------- ----------- Leeward Wall. -0..50 -9-0.53 -8.32 Side Walls -0.70 -26.30 -14.09 Wall Elev Kz Kzt Cp qz Press Press Total ft parr +GCpz -bpi apt-2Lpi ------------------------------------------------------------------- Windward 10.69 0.85 1.00 0.80 33.94 16.97 29.19 37.51 Windward 0.69 0.85 1.00 0.80 33.94 16.97 29.19 37.51 Roof Location Cp Pressure Pressure +GCpi(psf)-GCpi(psf) --------------------------------------------------------------------------- Windward - Min Cp -0.61 -23.71 -11.49 Windward - Max Cp -0.10 -8.99 3.22 Leeward Norm to Ridge -0.39 -17.36 -5.14 Overhang Bat (Windward onlyp 0.60 23.09 23.05 Notes - Normal to Ridge Note (1) Per Fig 27.4-1 Note 7, Since Theta > 10 Deg base ealcs on Mean Ht Note (2) Wall & Roof Pressures = Qh*(G4Cp - GCPi) Note (3) +GCpi = Positive Internal Bldg Press, -GCPi = Negative Internal Bldg Press Note (4) Total Pressure = Leeward Press + Windward Press (For + or - GCPi) Note (5) Ref Fig 27.4-1, Normal to Ridge (Theta>=10), Theta= 12.3 Deg, h/l= 0.17 Note (6) Overhang bottom based upon windward wall Cp and GCpi = 0. MWFRS-Wall Pressures for Wind Normal to 55 ft wall (Along Ridge) All pressures shown are based upon ASD Design, with a Load Factor of .6 Wall Cp. Pressure- Pressure +GCpi (psf) -GCpi (psf) --------------- ------ ----------- ----------- Leeward Wall -0.40 -17.61 -5.39 Side Walls -0.70 -26.30 -14.09 Wall Elev Kz Kzt Cp qz Press Press Total ft paf +40-Vi -GCpi +/-GCpi ------------------------------------------------------------------- Windward 17.24 0.87 1.00 0.80 34.95 17.66 29.88 35.26 Windward 10.69 0.85 1.00 0.80 33.94 16.97 29.19 34.58 Windward 0.69 0.85 1.00 0.80 33.94 16.97 29.19 34.58 Roof - Dist from Windward Edge Cp Pressure Pressure +GCpi(psf)-GCpi(psf) ---------------------------------------------------------------- Roof: 0.0 ft to 7.0 ft -0.90 -32.07 -19.86 Roof: 7.0 ft to 14.0 ft -0.90 -32.07 -19.86 Rcof: 14.4 ft to 27.9 ft -0.54 -20.53 -9.32 Roof: 27.9 ft to 82.9 ft -0.30 -14.76 -2.55 Notes - Along Ridge Note (1) Ref Fig 27.4-1, Parallel tp•Ri61V% Vlj), •h/1W %.1799 Wind Pressure on Components and Cladding (Cts l0•farti 1= : •: • • •• ••• •• • • • •• • ••• • ••• • ••• • • • •• • • • • • • • •• • •• • • •• ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • ,. �. a ' Roof not a Shown F ' 5,1 ,,1�2 1�2 RNN !1Is t r a Gable Roof ; < 8 <= 4�; a All pressures shown are based upon ASD Design, with a Load Factor of .6 Width of Pressure Coefficient Zone "a" = = 5.50 ft Description Width Span Area Zone Max Min Max P Min P ft £t ft"2 GCp GCp psf ps£ ----------------------------------------------------------------------- Front. Window L 12.00 4.00 48.0 5 0.88 -1.16 35.97 -45.46 Liv..Windows 12.00 5.16 61.9 4 0.86 -0.96 35.30 -38.70 Front.`i3iridow P. 12.0b 4.00 48.0 5 0.88 -1.16 35.97 -45.46 Entry Door 3.00 6.80 20.4 4 0.95 -1.05 38.20 -41.59 Rear. Sliding D 12.00 6.80 81.6 4 0.84 -0.94 34.59 -37.98 Rear.Bath Door 2.50 6.80 17.0 4 0.96 -1.06 38.67 -42.06 Rear Window 12.00 4.00 48.0 5 0.88 -1.16 35.97 -45.46 Left W 1 6.00 4.00 24.0 5 0.93 -1.27 37.77 -49.07 Left W 2 6.00 4.00 24.0 4 0.93 -1.03 37.77 -41.17 Left W 3 (bath) 3.00 3.00 9.0 4 1.00 -1.10 40.05 -43.45 Left W 3.00 4.00 12.0 5 0.99 -1.37 39.58 -52.68 Rear W 1 8.00 4.00 32.0 5 0.91 -1.22 37.02 -47.57 Rear W 2 6.00 3.00 18.0 4 0.95 -1.05 38.52 -41.92 &car W 3 Z_0.. 3_0a 6_n_ !i L_00 -L_40 4.0_05 -5a_63 Khcc:Comp. & Clad. Table 6-3 Case 1 = 0.85 Qhcc:.00256*V^2*Khcc*Kht*Kd = 33.94 psf • • • • • • • • • • • • • • • • • • • • • .... ....... . . ..... . ... .... . . .... .