RF-18-1609Miami Shores Village
10050 N.E. 2nd Avenue NE
Miami Shores, FL 33138-0000
Phone: (305)795-2204
F[ORIDA
ertlimt
Issue Date: 611912018
Permit NO. RF-6-18-1609
Permit Type: Roof
Work Classification: Tile/Flat
Permit Status: APPROVED
Expiration: 12/16/2018
Project Address Parcel Number Applicant
1218 NE 101 Street 1132050210020
ANDRE CHELALA
Miami Shores, FL 33138-2609 Block: Lot:
Owner Information Address Phone Cell
ANDRE CHELALA 1218 NE 101 Street
MIAMI SHORES FL 33138-2609
Contractor(s) Phone Cell Phone
BUILDING UNLIMITED (305)278-8188
Type of Work: Re Roof
Additional Info: RE -ROOFING FLAT AND TILE
Classification: Residential
Scanning: 3
Fees Due
Amount
Bond Type - Contractors Bond
$500.00
CCF
$16.80
DBPR Fee
$4.88
DCA Fee
$3.25
Education Surcharge
$5.60
Permit Fee - New Roof
$325.00
Scanning Fee
$9.00
Technology Fee
$22.40
Total:
$886.93
Valuation:=28,000.00Total Sq Fee
Pay Date Pay Type Amt Paid Amt Due
Invoice # RF-6-18-67899
06/12/2018 Cash $ 50.00 $ 836.93
06/19/2018 Check #: 2296 $ 836.93 $ 0.00
Bond #: 3803
AyaiiaDle Inspections:
Inspection Type:
Up Lift Report
I ue in rrogress
Roof in Progress
Renailing Affidavit
Review Roof
Cap Sheet
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that ag the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. Futher%iore, thorize the above -named contractor to do the work stated.
June 19, 2018
Aut�orized Signature: Owner / Applicant / Contractor / Agent
Building Department Copy
1
IlIIII IIIli IIIII IIIII III II IIIII illll IIII IIlI
NOTICE OF COMMENCEMENT
A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION
PERMIT NO! # /1"'40?TAX FOLIO NO
STATE OF FLORIDA:
COUNTY OF MIAMI-DADE:
THE UNDERSIGNED hereby gives notice that improvements will be made to
property, and in accordance with Chapter 713, Florida Statutes, the following
is provided in this Notice of Commencement.
1. Legal description of property and street/address:
2. Description of improvement: , yN G
STATE OF,
C:F1-4 2I! r 1uRr=Fv3:3 531 T
OR E K .3 i i 11"1 F's 21 2
'iYil•\4 �"'� _�. j4; �. i'i` ~i..!'�`.i �, _. 1. ail r..
C
,ORInA, COU DADE
i'TI F ' r 1at thia is coy/ of the �t o coact:>r�
r
//r
ht C-J C
above reserved for use of recording office
3. Owner(s) name and address: L- ,LYo 141 S-}- Oweary I 5 hovzS `� L
Interest in property:
Name and address of fee simple titleholder:
4. Contractor's name, address and phone number: bvii6im y t rn 1 6 W
3 31.3
5. Surety: (Payment bond required by owner from contractor, if any)
Name, address and phone number:
Amount of bond $
6. Lender's name and address:
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)7., Florida Statutes,
Name, address and phone number:
8. In addition to himself, Owners designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section
713,13(1)(b), Florida Statutes.
Name, address and phone number:
9. Expiration date of this Notice of Commencement:
(the expiration date is 1 year from the date of recording unless a different date Is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OFTHE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A OTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE
FIRST INSPECTION. IF YO NT D TO BTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK
OR RECORDING YOUR OTICE QF C9MMENCEMENT.
Signature(s) of Own (s) �)' Authorized Officer/Director/Partner/Manager
Prepared By Prepared By
Print Name _ Print Name
Title/Office Title/Office
STATE OF FLORIDA
COUNTY OF MIAMI-DADE
The foregoing instrument was acknowledged before me this _ day of_A�
I ividually, or ❑ as for
ersonally known, or ❑ produced the following type of identification.:
Signature of Notary Public:
Print Name:
(SEAL)
VERIFICATION PURSUANT TO SECTION_92.525, FLORIDA STATil11T &
Under penalties of perju clare that I have read the foregoing and
that the facts stated in ' are trdp, to the best of my knowledge and belief.
Signature(s) of Own r(s) or
By
mission GG 193011
05/04 2022
Officer/Director/Partner/Manager who signed above:
By
123 01-52 PAGE 3 6112
t
BUILDING
PERMIT APPLICATION
Miami Shores Village �^�c���,r
R F C D
Building Department JUN 12 L"].J
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 79S-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
-M, BUILDING ❑ ELECTRIC &!(ROOFING
❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS
F-"
((�BC 20 I
Master Permit No. V IC C:J _1LP0q
Sub Permit No.
❑ REVISION ❑ EXTENSION ❑RENEWAL
❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 12 I6 NF_ to k
City: Miami Shores County: Miami Dade Zip: 33k 3�
Folio/Parcel#: it - 32ci 5 - d 21 - COW Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): W re TamaVD Phone#:
Address: I2��
City: �)110rt S State: I Zip: 33I3 O
Tenant/Lessee Name: Phone#:
Email
CONTRACTOR: Company Name:
Address: el L % 5 W
City: NAioxti
Qualifier Name: Q(
State Certification or Registration #:
1
one#: 305 - 6o 1- z*)zo
State: I - Zip: 33 3y
.) n4 Phone#:
Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address: City: State: Zip:
Value of Work for this Permit: $ 27� 000 Square/Linear Footage of Work: !tamp,
Type of Work: ❑ Addition ❑ Alteration ❑ New pair/Replace ❑ Demolition
Description of Work: �— �ins IF to c1�%f� "J 7, 1�
Specify color of color thru tile:
Submittal Fee $
Scanning Fee $
Permit Fee $ 32S - M
Radon Fee $ 3 - Z S
Technology Fee $ Training/Education Fee $
Structural Reviews $
CCF $
CO/CC $
DBPR $ q - Gv & Notary $
Double Fee $
Bond $ a " a G
TOTAL FEE NOW DUE $
Bonding Company's Name (if applicable) _
Bonding Company's Address
City State
Mortgage Lender's Name (if applicable) _
Mortgage Lender's Address
Zip
City State Zip.
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. 1 understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT, IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $250Q the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature Signature
O
WNE Kr ENT CONTRACTOR
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
_,��J day of M A K 120 (� , by � day of M � Y 120 f � , by
7 n dre- -rQ m'L y,Aho is personally known to W?urf i A✓ tfi2y , who is personally known to
me or who has produced
as me or who has produced
identification and who did take an oath. identification and who did take an oath.
NOTARY PUBLIC:
of Ronda
C' r * Ate Rousseau
Print: S M Eommission^GG 193011
4_
Ds
Seal:
NOTARY PUBLIC:
as
**s****s**s*ssss***s****sss*ssss*****sss*#s#*****s*sss*ss*s*s*ssssss*s*s*ssssssss*s*ss*sssssssss*s*sssss**s
APPROVED BY Plans Examiner Zoning
Structural Review Clerk
(Revised02/24/2014)
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department Date: 5 - 3 o d'
10050 NE 2nd Ave
Miami Shores, Fl 33138
Re: Owner's Name:
Property Address: 12 A N f- 101 5+ I" ianrvi 'j kCFfr S f 1 3313
Roofing Permit Number:
Dear Building Official:
certify that I am not required to retrofit the roof to wall connections of my
building because:
t/fhe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad
valorem taxation.
o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions
of 1994 editioy(of the�South Flonoa-Building Code (1994 SFBC)
Print Name
State of Florida
County of Dade
The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned.
Sworn to and subscribed before me this aq, day of M44Y Zo / v
•.►r"�y� Notary Public State of Flonda
Notary Public, Sate of Florida at Large Jorge Rousseau A-1
Y
Expires 05104 2022
• When the just valuation of the structure for purpose of ad the building was not constructed with FBC not a 1994
SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation.
Revised on 5/21/2009
6/7/2018 Property Search Application - Miami -Dade County
A, APPRAISER
OFFICE OF THE PROPERTY
Summary Report
Property Information
Folio:
11-3205-021-0020
Property Address:
1218 NE 101 ST
Miami Shores, FL 33138-2609
Owner
ANDRE TAMAYO CHELALA &
TRACY BURNS JTRS
Mailing Address
1218 NE 101 ST
MIAMI, FL 33138-2609
PA Primary Zone
1100 SGL FAMILY- 2301-2500 SQ
Primary Land Use
0101 RESIDENTIAL -SINGLE
FAMILY: 1 UNIT
Beds / Baths I Half
3/2/0
Floors
1
Living Units
1
Actual Area
Sq.Ft
Living Area
Sq.Ft
Adjusted Area
2,393 Sq.Ft
Lot Size
12,812 Sq.Ft
Year Built
1946
Assessment Information
Year
2018
2017
2016
Land Value
$461,232
$429,202
Building Value
186
$173,350
$173,662
XF Value
$23,958
$24,222
$24,486
Market Value
$671,654
$658,804
$627,350
Assessed Value
$424,565
$415,833
$407,281
Benefits Information
Benefit
Type
2018
2017
2016
Save Our Homes
Assessment
$247,089
$242,971
$220,069
Cap
Reduction
Homestead
Exemption
$25,000
$25,000
$25,000
Second Homestead
Exemption
$25,0001
$25,000
$25,000
Note: Not all benefits are applicable to all Taxable Values (i.e. County, School
Board, City, Regional).
Short Legal Description
MIAMI SHORES SEC 8 AMD PB 42-40
N100FT LOT 5 BLK 184 A
LOT SIZE IRREGULAR
OR 20569-1646 07 2002 1
COC 24752-0536 07 2006 1
Generated On : 6/7/2018
Taxable Value Information
20181 20171 2016
County
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$374,5651
$365,8331
$357,281
School Board
Exemption Value
$25,000
$25,000
$25,000
Taxable Value
$399,5651
$390,8331
$382,281
City
Exemption Value
$50,000 $50,000
$50,000
Taxable Value
$374,5651 $365,833
$3571281
Regional
Exemption Value $50,000
Taxable Value- $374,565
$50,000
$365,833
$50,000
$357,281
Sales Information
Previous Sale
Price
OR Book -Page Qualification Description
07/01/2006
$890,000
24752-0536 Sales which are qualified
07/01/2002
$420,000
20569-1646 Sales which are qualified
03/01/1988
$130,000
13720-3477 Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property
Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disciaimer.asp
Version
Florida Building Code 6th Edition (2017)
1 Aigh-Velocity Hurricane Zone Uniform Permit Application Form
Section A General Information)
M ` r No. Process No.
o is '9 Name gU/L D) A) 6 CJ IV / oI') //y C
Add rss Z f o /t/ 1 d rS' /YI 1 %YI /L 3 5
ROOF CATEGORY
Low Slope❑ Mechanical Fastened Tile Mortar/Adheslvs Set Tile
Mechanically
❑ Asphamc ❑ Metal PaneUShingles ❑ Wood Shingles/Shakes
Shingles Are there
C E 1 V E D ❑ Prescriptive BURaiA3150 Gas Vent Stacks?
Yes❑ No
ROOF TYPE •
N 1 2018
Type: Nakur a1d LPdJQ • • • ; •
❑ New Roof e-Roofing ❑ Recovering ❑ Repair ;Q;1(aIntenaqce ; • • • ;
ROOF SYSTEM INFORMATION ' .... • : "' • • • • • •
...... .. . ....
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (Sjj•.. ; • • • •;
00 ..
.... .
.. . .. . .
Section B (Roof Plan) • • • • •
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow
scuppers and overflow drains. Include dimensions of sections and levels, clearly
Identify dimensions of elevated pressure zones and location of parapets.
"u%:u`an
on
"
■
`r%■C
•`r
'
'
a
C
C
CCCCCu`
M��
i
�■nniw■
C#:
%r
uu
:u�
.`
■■:�
uCC
■■
■■��a
■ur
■■�
►�-i':■C�iC�iG■■C■'■C`
�"
C
■�
:�C
p
C.rir":■i■
:CC■�.■�rLn�■■rC■
`awl
G�■_■rii
r�i
Ifs■'r
giii
'
CC
C
�/i�
■
�
n
u
C��
�•�
!
■
r
■
u
■
■
i
r
■r
i
_i0
`C
C
■
•
noun
uuCan
inn:
uC
ii
■ru`
::
C�
E
CC'i
C
n.c.
��1..,.�,
1
_r��
�d
�
Cp.�■■.CC�■��
u
■rr
0Ca
■■rC
CC;
�CE
.
�
CC
■■�
u�
u
.
C
u■
��C
u■•,
rC
■
�■
��C:'
i�
cc
■.`C
C
E
CC
CC'
CCC
'
CCD',�
�Cr
.,
n�C
, ,.
C
�pp
C
rrii�
C'r'
r��i
CC�
��
u
iii
��Ce:�C
■
r
■
'' �
'(�
"'C
'
�C
e
�C�
C'C�C:�.C'►�■CC"■CC:
a
r�C
u
.
EE■u
""i
�
"
C�i
no
■
C
�
.
C
.
■
C
■
R
r
�r
`u
■
■.
r
r
■.1
aG
■
�,��
EC
�
rrGiC'�i
■
�
C
C
1
,
`+�'i■
.
CC..
C�
C
■fir
■�`
C�C
■
■
C■
i
ii
i
nCi
C
Cu
�*■i�
CC
u
■'
r
iq
�
�
■
it
CC
■
■C.
��
C
■
`E
C
�rFir
'■
C:
■r
.Ca
C
■
■
■
C
i
�C
ri
r
C
123 01-48 1/18 PAGE 2
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF
THE UNIFORM ROOFING ' PERMIT
APPLICATION FORM AND ATTACH THE
REQUIRED DOCUMENTS AS NOTED BELOW:
.....
•••••
.....
Roof System
Required Sections of the
Attachments Required
Permit Application Form
See List Below
L�aruSlope Application
A,B,C
1,2,3,4,5,6,7
PI'l�'SCriptide BUR-RAS 150
A,B,C
4,5,6,7
Asphaltic $pjr<gles
A,B,D
1,2,4,5,ti,7
Fomete prtf tay Tile
A,B,D,E
1.2.3.4.5,6,7
I4etaL Ro
A,B,D
1,2,3,4,5,6,7
jNpod Shingles and
A,B,D
1,2,4,5,6,7
Sttdkes
Other
As Applicable
1,2,3,4,5,6,7
1.
Fire Directory Listing Page
2.
From Notice of Acceptance:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if Applicable, RAS 127 or
RAS 128
4.
Other Component Notice of Acceptances
5.
Munlci al Permit Application
6.
Owners Notification for Roofing Considerations Re -Roofing On
7.
An Required Roof Testing/Calculation Documentation
F
123 01-48 1/18 PAGE 1
. .
....
......
......
.. .
......
A
....
.
.....
7
s
1Y'
df'
J"
/
w
i
�
-L3
��
q
T
o Pe N
4—
lqi!
Tile Roof System
• MIAMFI]u4DE
EZ
Miami -Dade County HVHZ Electronic Roof Permit Form
Section D Tile Roof System
"Delivering Excellence Every Day"
Roof System Manufacturer. I ENTEGRA ROOF TILE LLC
Notice of Acceptance Number (NOA): 14-0416.12
Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations):
P 1: -39.1 P 2: -68.1 P 3: -100.7
Maximum Design Wind Pressures, (From the NOA Specific system): 29.3 psf
Fill in the specific roof assembly components. If a component is not required, insert not applicable (n/a) in the text box.
Roof Slope: 712"
Roof Mean Height: 14 ft.
Method of Tile Attachment:
1--Adhesive, 2 Small Paddy Polyfoam Polypro—
Alternate Method of Tile Attachment per NOA:
n/a
Drip Edge Size & Gauge: —3" face 26 ga.—
Drip Edge Material Type: r-Galvinized Metal —
•
Deck Type:
—5/8" PlyVod '
• •
• • • • •
.
......
.. .
......
Optional insulation: •
•
•
••••••
NA
....
.
.....
Optional Nailable Substr t
. •
• • •
• • • • • •
NA
•
. .
. .
......
Optional Nailable Substrat tta
ment:
• • • • • •
NA
•
Basesheet Type:
ASTM FELT D226 30#
Fastener Type for Basesheet Attachment:
1-1/4 rs nail & tin cap 1-5/8" 6"oc @lap 12"oc
Tile Underlayment (Cap Sheet) Type:
/ T17,-T - ri,o er
Tile Underlayment Attachment Method:
HOT MOP ASPHALT
Drip Edge Fastener Type: 1-1/4" RS NAIL 4" OC Tile Profile:
GALENA SPANISH "S" CONCRETE TILE
Hook Strip/Cleat gauge or weight: — Select Hook Strip —
Section E
Mlar�iFclo►oE
"Delivering Excellence Ever)' Day"
Miami -Dade County HVHZ Electronic Roof Permit Form
Section E (Tile Calculations)
Method 1 "Moment Based Tile Calculations Per RAS 127"
For Moment based tile systems, use Method 1. Compare the values for Mr with the values from ME If the Mf values are
greater than or equal to the Mr values, for each area of the roof, then the file attachment method is acceptable.
P 1: -39.1 x X0.235 = 9.1139 _ Mg: 6.03 = Mr1: EEg 29.3 NOA Mf
P 2: -68.1 x 0.235 = 16.00 _ Mg; 6.03 = M2; 9.97 5 29.3 NOA Mf
P 3: -100.7 x 0.235 = 23.67 _ Mg; 6.03 = Mr3: 17.64 < 29.3 NOA Mf • • • • • •
. . .... ......
Method 3 "Uplift Based Tile Calculations Per RAS 127" •
...... .. . ......
For Uplift based file systems use Method 3. Compare the values for F' with the values for Fr. If the F values are greater #Vp or equajto tht3Fr valueg,18r•' ;
each area of the roof, then the the attachment method is acceptable. •0000 • • • • • • •
ee
P1: =x I: x w: W. x cos B: Fr1: N A F'
60
P2:=x1:===xw:===-W=== xcos9:F_1=Fr2:�5 NOA•F' �••••�
P3:=xl:===xw:===-W:=== xcose:�=Ft'3: s abA'i' . •
Where to Obtain Information to complete the calculations
Description
Symbol
Where to Find
Design Pressure
P1 or P2 or P3
Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional
engineer based on ASCE 7.
Mean Roof Height
H
Job Site
Roof Slope
9
Job Site
Aerodynamic Multiplier
7l
Product Approval (NOA)
Restoring Moment due to Gravity
Mg
Product Approval (NOA)
Attachment Resistance
Mf
Product Approval (NOA)
Required Moment Resistance
Mr
Calculated
Minimum Attachment Resistance
F'
Product Approval (NOA)
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval (NOA)
Tile Dimensions
I — length
w = width
Product Approval (NOA)
MIAMI-DADE COUNTY
MIAMEI�ADE PRODUCT' CONTROL SECTION
" 11805 S W 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami. Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) ++++�+.miamidaae.mi+lcronnm�
Entegra Roof Tile, LLC
1289 NE 9"' Ave
Okeechobee, FL. 34972
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product C44rpjSectiog.....
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) re!%"d tae right.tp.bave this .'
product or material tested for quality assurance purposes. If this product or material fails.W pt rForm Ctbg accepted...:.
manner, the manufacturer will incur the, expense of such testing and the AHJ may immsdWWV revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to.revoke this aceeptanc4 •
if it is determined by Miami -Dade County Product Control Section that this product or material faiVto meet the..•s
requirements of the applicable building code. ...... .. ..:..'
This product is approved as described herein, and has been designed to comply with irie OMorida guilaing Code o * • :
including the High Velocity Hurricane Zone of the Florida Building Code. : •
. . . . ......
DESCRIPTION: Galena Spanish "S" Concrete Roof Tile • • •
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA 10-0518.04 and consists of pages 1 through 6.
The submitted documentation was reviewed by Juan E. Collao, R.A.
NOA No.: 14-0416.12
Expiration Date: 11/18/19
Approval Date: 11/27/14
Pagel of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Galena Spanish 'IS" Concrete Roof Tile, as manufactured by Entegra Roof
Tile, LLC as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code
for High Velocity Hurricane Zone. For the locations where the pressure requirements, as determined by applicable
Building Code, does not exceed the design pressure values obtain by calculations in compliance with RAS 127 using
the values listed in section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
•ss•
Manufactured by
. .... ......
Test • I;rluct •
Applicant
Dimensions
Snecifications ilesctiption."" '
Galena Spanish'S' Roof
L = 17"
...... .. . •...••
TAS 112 High profile,,jgt*jlp*king, one piece, "S; .
Tile
W = 10"
shaped, concrete jgof tile eAuipi4ed with.
H = 2.7"
two nail hole3'..F.prirect V9 of
Thickness: ''/2"
battened nail esio awrtar or adhesive set ..:.. •
applications... .. . .. ......
Trim Pieces
L = varies
TAS 112 Accessory trim, concrete ro nf.piFies for* • • • •
W = varies
use at hips, r#es,.04ges and valley ; •
Varying thickness
� � •;
terminations. Manufactured fVVch tilt •
profile. • • •
2.1. MANUFACTURING LOCATION
1. Okeechobee, FL
2.2. EVIDENCE SUBMITTED
Test Aeency
Test Identifier
Test Name/Report Date
Redland Technologies
7161-03
Static Uplift Testing Dec. 1991
Appendix 1I1
PA 102 & PA 102(A)
Redland Technologies
7161-03
Wind Tunnel Testing Dec. 1991
Appendix 11
PA 108 (Nail -On)
Redland Technologies
P0647-01
Wind Tunnel Testing Aug. 1994
PA 108 (Mortar Set)
Redland Technologies
P0402
Withdrawal Resistance Testing of Sept. 1993
screw vs. smooth shank nails
The Center for Applied
94-084
Static Uplift Testing May 1994
Engineering, Inc.
PA 101 (Mortar Set)
The Center for Applied
94-083
Static Uplift Testing April 1994
Engineering, Inc.
PA 101 (Adhesive Set)
NOA No.: 14-0416.12
Expiration Date: 11/18/19
Approval Date: 11/27/14
Page 2 of 6
Test Aaencv
Test Identifier
Test Name/Report
Date
The Center for Applied
25-7183-4
Static Uplift Testing
Feb. 1995
Engineering, Inc.
PA 102 (2 Quik-Drive Screws, Direct
Deck)
The Center for Applied
25-7214-3
Static Uplift Testing
March, 1995
Engineering, Inc.
PA 102 (1 Quik-Drive Screw, Direct
Deck)
Redland Technologies
Letter Dated Aug. 1,
Wind Tunnel Testing
Aug. 1994
1994
PA 108 (Nail -On)
The Center for Applied
Project No. 307025
Wind Driven Rain
Oct. 1994
Engineering, Inc.
Test #MDC-78
PA 100
Nutting Engineering
13343.1
Physical Properties
June 2007
TAS 112
Celotex Corporation Testing
520111-3
Static Uplift Testing
Desa1998
Service
520191-2-1
PA 101 . •
Uwcb*1999 .•.••.
Walker Engineering, Inc.
Calculations
Two Patty Adhesive Set 93arn:
Apaii,1999 •o
Walker Engineering, Inc.
Evaluation Calculations
25-7094 • • • • • •
FebNiar; 1996• • • •: •
Walker Engineering, Inc.
Evaluation Calculations
25-7496 • • • : • •
Aph 11996 • •
Walker Engineering, Inc..
Evaluation Calculations
25-7584 • • • •
Dg�eatgr 199& •
0 •
25-7804b-8 ••••
• •••••
25-7804-4 & 5 ••;••;
;•• •� ••••••
25-7848-6 •'
Walker Engineering, Inc.
Evaluation Calculations
25-7183 ;";';
March 1995 '•
Walker Engineering, Inc.
Evaluation Calculations
Restoring Moment Due to t3ravit3
:0944109 • •
Walker Engineering, Inc.
Calculations
Aerodynamic Multiplied
09/14 /09 • • • •
American Test Lab of South
RT0624.04-14
TAS 112
•07%b7714
Florida
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product
Control office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 14-0416.12
Expiration Date: 11/18/19
Approval Date: 11/27/14
Page 3 of 6
4. INSTALLATION
4.1 Galena Spanish "S" Concrete Roof Tile and its components shall be installed in strict compliance with
Roofing Application Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (lbf)
1
Length-1(ft)
1
Width-w (ft)
Galena Spanish 'S' Roof Tile
8.5
1.42
0.833
Table 2: Aerodynamic Multipliers - A, (ft)
Tile X (fe)
Profile Direct Deck Application * 0 0 0
Galena S anish 'S' Roof Tile 0.235
...... .. . .
Table 3: Restoring Moments due to Gravity - M9 (ft-lbf)• • • •
Tile
Profile
2"•12"
318•12"
VAT'5"•12"
6"• I,�`r•••
�'� 1200or •
••••
rester •
Galena
Direct
Direct
Direct
Direct
Direot: • •;
; Djrer,X •
Spanish
Deck
Deck
Deck
Deck
Deek • •
• Deck •
'S' Roof
Tile
6.20
6.13
6.03
5.89
• • • • •:
5.7;1
5.0
Table 4: Attachment Resistance Expressed as a Moment - Mr ( - bf) •
for Mechanically Attached Systems
Tile
Fastener Type
Direct Deck
Direct Deck
Profile
min 16132" plywood)
min. 19132" plywood)
Galena
2-10d Ring Shank Nails
28.6
41.2
Spanish 'S'
1-10d Smooth or Screw
Roof Tile
Shank Nail 2
5.1
6.8
2-10d Smooth or Screw
Shank Nails
6.9
9.2
1 #8 Screw
20.7
20.7
2 #8 Screw
43.2
43.2
1-10d Smooth or Screw
Shank Nail Field Cli 2
23.1
23.1
1-10d Smooth or Screw
Shank Nail Eave Cli
29 3
29.3
2-10d Smooth or Screw
Shank Nails Field Clip)
27.6
27.6
2-10d Smooth or Screw
Shank Nails Eave Clip)
38.1
38.1
2-10d Ring Shank Nails 33.1 48.1
1 Installation with a 4" the headlap and fasteners are located a min. of 2 W from head of tile.
2 When using only one fastener use the hole that is approximately 4 %" away from Interlocking edge.
MIAMWADE COUNTY
NOA No.: 14-0416.12
Expiration Date: 11/18/19
Approval Date: 11/27/14
Page 4 of 6
Table 5: Attachment Resistance Expressed as a Moment Mr (ft-lbf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment Resistance
Galena Spanish 'S' Roof Tile
Adhesive
29.34
3 See manufacturer's component approval for installation requirements.
4 The Dow Chemical Company TileBond Average weight per patty 10.7 grams.
3M_ 2-Component Foam Roof Tile Adhesive AH-160, average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mr (ft-lbf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Galena Spanish 'S' Roof
3M' 2-Component Foam Roof Tile Adhesive AH-160
66.5•'• • • .
Tile
3M2-Component Foam Roof Tile Adhesive AH-160
•.. • 38.7:...
5 Large paddy placement of 63
grams of 3M_ 2-Component Foam Roof Tile Adhesive AH-160. • • • • • • • • •
6 Medium paddy placement of 27 grams of 3M_ 2-Component Foam Roof Tile Adhesive AH-160.
Table 7: Attachment Resistance Expressed as a Moment - Mr(R 14Q. •
for Mortar or Adhesive Set Systems 60,1066•
Tile
Profile
Tile Application
MiWnwm Attachment
; 6Resist •
Galena Spanish 'S'
Roof Tile
Mortar Set
• • • • ; 24.5 .. .
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
OR
6_�_ `
v��7ENTERRR
GALENA SPANISH "S" CONCRETE ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
NOA No.: 14-0416.12
Expiration Date: 11/18/19
Approval Date: 11/27/14
Page 5 of 6
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
PROFILE DRAWINGS
GALENA SPANISH "S" CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
MU1MWiADE COUNTY
NOA No.: 14-0416.12
. , Expiration Date: I1/18/19
Approval Date: 11/27/14
Page 6 of 6
MfAM1 DAMDEf
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) w•ww.miamidade.sov/economy
ICP Adhesives and Sealants, Inc.
12505 NW 44a' Street
Coral Springs, FL. 33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product • •
or material tested for quality assurance purposes. If this product or material fails to perform j%the acceptg0.Wnner, the • •
manufacturer will incur the expense of such testing and the AHJ may immediately revoke• p1q jify, or stspbn4 the usg• •; •
of such product or material within their jurisdiction. RER reserves the right to rev" ibis acceptance, if it .is
determined by Miami -Dade County Product Control Section that this product or material faiL%to,meet the recViiremerV
.... . • of the applicable building code. 0 • •
.....
This product is approved as described herein, and has been designed to comply with:tire:�trida 31uilctixg Coae:0.•
including the High Velocity Hurricane Zone of the Florida Building Code. •
. . . . ......
DESCRIPTION: ICP Adhesives Polyset® AH-160 :....:
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and Following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-0322.03
APPMIAMI•DAROVED TY'Ali Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 1of11
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described
in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP
Adhesives Polyset® AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description....
Specifications . . •....' ......
ICP Adhesives N/A TAS 101 Two component pol*uretiiane feana adhesive •.
Polyset®AH-160 u.: 9 0 0& • • i• 6 0•
...... • •
ICP Adhesives Foam N/A Dispensing Equipment ... : 0 0 0 •
Dispenser RTF1000 .... • •
. .....
.... .. .
ICP Adhesives ProPack® N/A Dispensing Equipmen. .....t • •
.. .. . .. ......
30 & 100
. . . . ......
PRODUCTS MANUFACTURED BY OTHERS: • • • • • • • •
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset® AH-160 roof the adhesive.
MANUFACTURING LOCATION:
1. Tomball, TX.
PHYSICAL PROPERTIES:
Property Test Results
Density ASTM D 1622 1.6 lbs./ft.3
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Ft2
Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch
Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -400 F., 2 weeks
+6.0% Volume Change @I58°F., 100% Humidity, 2
weeks
Closed Cell Content ASTM D 2856 86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2 of 11
EVIDENCE SUBMITTED:
Test Asency
Center for Applied Engineering
Miles Laboratories
Polymers Division
Ramtech Laboratories, Inc.
Southwest Research Institute
Trinity Engineering
Celotex Corp. Testing Services
Test Identifier
#94-060
257818-1 PA
25-7438-3
25-7438-4
25-7438-7
25-7492
NB-589-631
9637-92
01-6743-011
01-6739-062b[l]
7050.02.96-1
P36700.04.12
P39740.02.12
528454-2-1
528454-9-1
528454-10-1
520109-1
520109-2
520109-3
520109-6
520109-7
520191-1
520109-2-1
Test Name/Renort
TAS 101
TAS 101
SSTD 11-93
SSTD 11-93
SSTD 11-93
ASTM D 1623
ASTM E 108
ASTM E 108
ASTM E 84
• • •
TAS 114
•••;••
ASTM D 1623
....
TAS 101
'....'
TAS 123
......
TAS 101
••••••
TAS 101
•"� '
TAS 101
Date
04/08/94
12/16/96
10/25/95
11 /02/95
12/12/95
02/01 /94
04/30/93
1.1111 9%§4
01%16%95
....
01446
QAII8/12
COVA2
V.
10/23/98
127209
•• •
03/02/99
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof the adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
INSTALLATION:
1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH-160.
2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTFI000 dispensing equipment is requited befdte 6Vp}icatioil.....
of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintaimj between
1.0-1. IS (A): 1.0 (B). • ...... .. . ......
6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser•I TF7000 or ICP :....:
Adhesives ProPack® 30 & 100 dispensing equipment only. • • • •
.... . .....
7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. ...... .. ..:..'
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within I to 2 minu%s aVer ICP Adhesives • • • •:
Polyset® AH-160 has been dispensed. • • • •
. . . ......
9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance witli e •
'Placement Details' herein. Each generic tile profile requires the specific placement noted*hetein. • • • • •
NOA No.: 17-0322.03
MIAM14= COUN7Y Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Minimum Paddy Contact
Minimum Paddy Gram
Area
Weight
Eave Course - Flat, Low, High
All Eave Course
17-23 sq. inches
45-65
Profiles
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches
30
Low Profile
#2
12-14 sq. inches
30
High Profile
#2
17-19 sq. inches
30
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at
12 grams per paddy
head of tile 9-11 sq. inches at
overlap
0000
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal:
7 grarmeM bead ••
edge) 20-25 sq. inches each
• • • •
bead
.
....
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
• ! •34 gran:% gpf%r pan •
....
.
.....
......
.. .
.....
•• ••
••
••••••
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable inarL';g of tiv
• • • • •
manufacturer's name or logo and following statement: "Miami -Dade County Product ControtApptgved"
• •: •
Cr the Miami-.*....
Dade County Product Control Sea] as shown below. • •
• •
•
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
ADHESIVE PLACEMENT DETAIL # 1
Nall throualtplasthcarnant _paddyl6•nashUimp
b t*nroqulradl, 11
loll X
riAr.OensOph071a1 yr �\��� y-•.•4•�. _� ''�
EavtColl"O' j
.s'" ° it :-=;.,r.i�' �_ �'- /_`..r•'�:-' r-''
✓J2�.'-ice.
Nall through plastic cement.
When regldred j
11 Nally i84"Niah WWI
tt"trWrlayleuel[ it �
. `v yid •�`�.� F _ ' +.
r01n.x �.•
5 21Rwld*-
Ballensoptlonal
Ir
10
yo Ciosute
EawaCourse - - l'`•�� �fasci•
N.il *-nl!A pl••ele ur i!•
tiwhan rrquirso �% �-•- • pAddr larnmeth Mal
UndieliyMRit s�o`�� '- _ ��
lain N
Ea�+rtoursr--41Weephole
Fascia
lain, tin. ' `V •�' y` Eareclosure
Drip edge
-
APPROVED J
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2)— 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
• • •••• ••••••
Medium Profile / Doubled 7'jle ....;.
•
1. Starting at the eave coursal ap ly a rainimum 2 • -
(50.8 mm) x 10" (254 rAn* is f" (2540mmj foam • • • • •
paddy onto the underlaymepositione j as�shown, • o • o •
rlb
under the pan portion of thertile closest tathe • • • • • •
overlock of the tile beiigS14! • 0 •
• • • • ••••••
2. Continue in same mann&r. Itrsure approximately IV• • • -
(109.7 cm') — 23 (148.4 cm2) square +r c%ae dhesiv•
contact with the underside of the tile.
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the the closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 6 of 11
ADHESIVE PLACEMENT DETAIL # 2
Kill through piruiet•m■nt p•ddK18p1sp•lh7.ldl
(when required),
rj�y K, t
Ondorlaymam
z J{'
BattwfcaipGona) ,�- �=—
UwCourso. —
da
Ewt-Ousure-___�
through plastic cement
Battens optional
Fait-
Flat/Low Profile Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cm')
— 23 (148.4 cm') square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock ibf tl%tile
being set. •••• ••••••
3. Continue in same manner.'Ifil3Pe approxHately 10" • • • • • •
(64.5 cm) - 12 (77.4 cm) square inch adhesive • • • • • •
contact with the undersides M tile. : • • •: • •
•... . .....
•••••• •• • •••••
. .• • .. ...•..
Medium Profile / Double P4 Tits e e
• • • • ••••••
l . Starting at the eave coursep apply a minnnum 2" (50.9
mm) x 10" (254 mm) x 1"•(104 irim) foam paddy � • • • •
onto the underlayment positioned as showri udder the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cmz) —
23 (148.4 cm') square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8min)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the the closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cm') square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
Nap through plastic ccptnt .
(whenrequlred) ,f , p ddxlB.K*kthTile?
ttpd•rl�ym nR �� `��•�'
Battensoptlonal
Y Brave Cvu+se =„yT �j/ 'SA fsYcin
}xf ph
1
n. Enire tlasar! 0itt`2en.lrDrip edge
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cmZ) —
23 (148.4 cm') square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under tbgpan
portion of the the closest tg the gverlocil pf lbetile ......
being set. .. ....
...... .. . ......
3. Continue in same manner. 4n m eapproximately 17" • • • •
(109.7 cmZ) - 19 (122.6 cno square inch Nb;jive •
contact with the underside df'the tile. ' • • • •
...... .. . .....
.. .. . .. ......
. . . . ......
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8of11
ADHESIVE PLACEMENT DETAIL ## 3
mail Uvoughplastic cement Paddy(between tiles)
(when requiredl
Battens optional
" Paddy lundertile)
single paddy y
Y on top of tile
x41nq _.
undertii
smglepaddy
onundedayment 2x4in. -'
s�
cta
—Eave Closure
FlattLow Profile Tile
Nail through plastic cement Single paddy under tile
Iwhen required)
Paddy (between tiles)
Battens
Paddy [under Mel
optional
• single paddy
or,tap oftla
,
`f4z41n.
2x4in.'�.��
7.
5mgglepaddyon
undertaymeut -
-
t0' ._ 21n.
Eave Closure
Eave Course
Fasda
Medium Profile Tile
1. On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x I" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (101.6 mm) up from the eave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 in' (109.7-148.4 cm') of
adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm) : 4" Q 01.6 run*l : * �' (25.4 • � • • •
mm) foam paddy onto they �Iftdgrlayme�tItIst below •
the second course line ppj4 Wd foa%28dcty ....
;
under the strengtheningr"UXat tile, ol;under the
pan portion of the tile, closelitto the underlock for:
the second course the to U%imTalled.:l'nsure .....
approximately 8-9 in' (5.1g6-,6&1 cml of adhesive* .: • • •
contact with the undersideofthe tile.• • • • • • • • •
•
. . . . ......
(Instructions continued on nIxt pilge) '
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
Nallthroughplasdcce
Singie paddy under dle
Iwhen required)
Paddy ibetween dies)
Battens
optional
Paddy[undert)lel
FS°�giepaddy
eO amen
4 x 41n.
V�'•
Single 2 x 4 in.
paddyy on
tap
f
`•`
Eave Course
Fascia
Weephole
loin. 2 in.
Eave dosure
Drip edge
High ProtileT)le
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x W
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cmZ) - 11 (71cm') square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cmZ) - 9 (58.1 cmZ) square inch
adhesive contact with the underside of the the at
the head of the tile. Continue in same manner.
• •
••••
••••••
•• •
••••
•
••••••
•• •
••••••
•
••••
•
• •
• .
••••%
••••
•
•••••
••••••
•• •
•••••
•
• •
•
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
1) Place enough adhesive to achieve 65 to 70 sq.
in contact with the pan tile.
2)Tum covers upside down. Place adhesive In
to 1 In.from outside edge of covertile.
Then install the tile. Ensure 20 to
25sq.In,cantedarea.
IUnderlayment
Eave closure
(motor showni
Fascia
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
Steep
Remove top portion of the eave course cover tile. Abut to second course of
pan tiles. Ensure eave end of pan and cover tiles are flush at save line.
Two Piece Barrel - High Profile Tile
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocking until adhesive has a chance to
cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cmZ) — 70 (451.6 cm')
..
square inch adhesive contact with *tOeeunderside
... eeeeee
of the pan tile. •
a.eeea ae • a.eeee
3. Turn covers upside dpwavWosing theeunderside
of the tile. Apply a mindluum 1" (25.4 man) x 11"' • • •:
(254 mm) bead of adhesive, airectl; on tale inneie e e e
edge of each side of the cover tile. Deave so***
approximately 3/4" (14mnj to 1" f25.44m) • • • • • •
from the outside edge;OPt tile, inward, free of • •
foam to allow for exp9nsion' ; e e e;. " • •' •
a
4. Turn cover tile over after foam is of iA end •
place onto pan tile course. Insure a minimum of
20 (129 cm2) - 25 (161.3 cmZ) square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11
it
1
1
1
1
Section C (Low Slope Application)
1 Fill in specific roof assembly components and identify
1 manufacturer
1 (If a component is not used, Identtfy'as "NA")
1 System Manufacturer. GAF
1
Product Approval No.: 15-1020.01
1 Design Wind Pressures, From RAS 128 or Calculations:
P 1: —42.8 P2: —71.7 P3: —108.0
Max. Design Pressure, from the specific product
approval system: -szs
Deck:
Tvoe- PLYWOOD 5/8"
n
Gauge/Thickness:
5/8
Slope: 0.25-12rr
Anchor/Base Sheet & No. of Ply(s): GAF GLASSBASE 75#
Anchor/Base Sheet Fastener/Bonding Material:
1 1-1/4" IRS NAIL AND TIN CAP 1-5/8'
1 1 Insulation Base Layer:TAPERED ISO
1 1 Base Insulation Size and Thickness: 1 " 4'X4'
1 Base Insulation Fastener/Bonding Material:
HOT MOP ASPHALT
' Top Insulation Layer: NA
Top Insulation Size and Thickness: NA
1
1 Top Insulation Fastener/Bonding Material:
1
Base Sheet(s) & No. of Ply(s): GAF STRATAVENT PERFORATED
1 Base Sheet Fastener/Bonding Material:
1 LAID LOOSE
1 GAF RUBEROID 20 (1)
1 Ply Sheet(s) & No. of Ply(s):
1 Ply Sheet Fastener/Bonding Material:
1 HOT MOP ASPHALT
1 Top Ply:
GAF MINERAL CAP SHEET
1
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form
Top Ply Fastener/Bonding Material:
HOT MOP ASPHALT
Surfacing: GRANULES
Fastener Spacing for Anchor/Base Sheet Attachment:
Field: 9 " oc @ Lap, # Rows 2 @ 9 " oc
Perimeter. 6 -cc @ Lap, # Rows q @ 6 " oc
Comer: 6 " oc @ Lap, # Rows 4 @ 6 " oc
••••
Number of Fasteners Per Insulation Boaed: • • • • • •
NA NANA ••••
Field Perimeter ::'*
NO"er • � • •
Illustrate Components Noted and Details" WA **cable:
Woodblocking, Gutter, Edge Terminattop,Wftng, Flalt�JQg
Continuous Cleat, Cant Strip, Base Flashiay,"unterflashing,
Coping, Etc. 000900 • • •
Indicate: Mean Roof Height, Parapet HjIgMt, Vbight ofe.B85g. •
Flashing, Component Material, Material Thickness, Fastener
Type; Fastener Spacing or Submit ManVCtlfre@*s Details that
Comply with RAS 111 and Chapter 16. ' ' ;.. •;.
S
0"
e!
/v I
Parapet
jont?R) i5
Height
I 1'j i,t,lir � �) eY
Mean
Roof
Height
TGFU.R1306 - Roofing Systems
Page 4 of 48
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polylsocyanurate or urethane or
perlite/polylsocyanurate composite or perlite/urethane composite or wood fiber/polylsocyanurate composite or phenolic, 2-In. maximum.
Ply Sheet: — Two or more plies Type GI "GAFGLAS@ Ply 4" or "Tri-Ply@ Ply 4" or "GAFGLAS@ Flex Ply 6" or "Tri-Ply@ Ultra -Flexible Ply
6", fully adhered with hot roofing asphalt.
Cap Sheet: — Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri-Ply@ BUR Granule Cap Sheet" or "GAFGLAS@ EnergyCap'"
Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt.
11. Deck: NC Incline: 2
Base Sheet: — One ply Type G2 "GAFGLASO #75 Base Sheet" or "Tri-Ply@ #75 Base Sheet" or "GAFGLASO #80 Ultima'" Base Sheet"
or "GAFGIAS@ Stratavent@ Nallable Venting Base Sheet" or "GAFGLAS@ Stratavent@ Perforated Venting Base Sheet", mechanically
fastened or fully adhered with hot roofing asphalt.
Ply Sheet: — One or more plies Type G1 "GAFGIAS@ Ply 4" or'Tri-Ply@ Ply 4" or "GAFGLAS@ Flex Ply 6" or'rri-Ply@ Ultra -Flexible Ply
6", fully adhered with hot roofing asphalt.
Cap Sheet: — Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri-Ply@ BUR Granule Cap Sheet" or "GAFGLAS@ EnergyCap'"
Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt.
12. Deck: C-15/32 Incline: 1
Barrier Board (Optional): — One or more layers minimum 1/4-In. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or
"DensDeckO Prime Roofboard" or "DensDeck@ DuraGuard"' Roofboard" or minimum 1/4-In. thick United States Gypsum Co.
"SECUROCK@ Roof Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX).
Insulation: — One or more layers perlite or glass fiber or polylsocyanurate or urethane or perlite/polylsocyanurate composite or
perlite/urethane composite or phenolic, 1-in. minimum (insulation joints offset a minimum of 6-In. from plywood deck joints).
Base Sheet: — One or more plies Type G1 "GAFGLAS@ Ply 4" or "Tri-Ply@ Ply 4" or "GAFGLAS@ Flex Ply 6" or "Tri-Ply@ Ultra -Flexible
Ply 6" or Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri-Ply@ *75 Base Sheet" or "GAFGLAS@ #80 Ultima'" Base Sheet" or "GAFGLASO
Stratavent@ Nallable Venting Base Sheet" or "GAFGLAS@ Stratavent@ Perforated Venting Base Sheet" or Type G3 "GAFGLAS® &Moral
Surfaced Cap Sheet" or'Tri-PlyO BUR Granule Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt • •
Membrane: — One or more piles "RUBEROID@ Torch Smooth" or "Tri-Ply@ APP Smooth" or "Tri-Ply@ APP ;ranW!".pr "RUBEIT(TIM
Torch Granule" or "RUBEROID@ Torch 180", torch applied or "RUBEROID@ Mop Smooth" or "RUBEROID@ Mop6moath 1.5" ore • • •
"RUBEROID@ Mop Plus Smooth" or "RUBEROID@ Mop Granule" or "Intec Flex PRF" or "Tri-Ply@ SBS Granulg i luft ldhered a�h Mot:
roofing asphalt. •
Cap Sheet: — Type G3 "GAFGLASO Mineral Surfaced Cap Sheet" or "Tri-Ply@ BUR Granule Cap Sheet" or 'CAlil"S@ EnergyCalrl"
Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. • • • • • •
13. Deck, C-15/32
Incline: 1
Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDetk@ Roofboartl"' er •
"DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuard'" Roofboard" or minimum 1/4-In. thick United St•aLhS Wsum Co.'
"SECUROCKO Roof Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX). • • • • • • •
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polylsocyanurate or urohan@ of •
perlite/polylsocyanurate composite or perlite/urethane composite or wood fiber/polylsocyanurate composite or phenolic, any r}:iC QeL
Base Sheet: — Two or more plies Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri-Ply@ #75 Base Sheet" or GAFGL91.S@ #80 tlitima'"
Base Sheet" or "GAFGLAS@.Stratavent@ Nallable Venting Base Sheet" or "GAFGLAS@ Stratavent@ Perforated WAntiog Base SWV pr
Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri-Ply@ BUR Granule Cap Sheet", mechanically fastened or fully adhe•d with Mot
roofing asphalt. • • •
Ply Sheet (Optional): — One or more plies Type GI. "GAFGLAS@ Ply 4" or "Tri-Ply@ Ply 4" or "GAFGLAS@ Ply Flex 6" or "Tri-Ply@ Ultra -
Flexible Ply 6", fully adhered with hot roofing asphalt.
Membrane: — One or more plies "RUBEROID@ Torch Smooth" or "Tri-Ply@ APP Smooth" or 'Tri-Ply@ APP Granule" or "RUBEROID@
Torch Granule" or "RUSEROID@ Torch 180", torch applied or "RUBEROID@ Mop Smooth" or"RUBEROID@ Mop Smooth 1.5" or
"RUBEROIDO Mop Plus Smooth" or "RUBEROID@ Mop Granule" or "Intec Flex PRF" or "Tri-Ply@ SBS Granule", fully adhered with hot
roofing asphalt.
Cap Sheet: — Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or'Trl-Ply@ BUR Granule Cap Sheet" or "GAFGLAS@ EnergyCap""
Mineral -Surfaced Cap Sheet", fully adhered with hot roonng asphalt.
14. Deck: C-15/32
Incline: 2
Barrier Board (Optional): — OOne or more layers minimum 1/4-In. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or
"DensDeck@ Prime Roofboard" or "DensDeck@ DuraGuard'" Roofboard" or minimum 1/4-In. thick United States Gypsum Co.
"SECUROCK@ Roof Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX).
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polylsocyanurate or perite/polylsocyanurate
composite or wood fiber/polylsocyanurate composite any thickness mechanically or adhered with hot roofing asphalt
Base Sheet: — One ply "GAFGLAS@ Stratavent@ Perforated Venting Base Sheet" or Type G2 "GAFGLAS@ #75 Base Sheet"or "Tri-Ply@
#75 Base Sheet" or "GAFGLAS@ *80 Ultlma— Base Sheet" or "GAFGLAS@ Stratavent@ Nallable Venting Base Sheet" or "GAFGLAS@
Stratavent@ Perforated Venting Base Sheet", mechanically fastened or fully adhered with hot roofing asphalt.
Ply Sheet — Two or more plies Type GI "GAFGLAS@ Ply 4" or -rri-Ply@ Ply 4" or "GAFGLASO Ply Flex 6" or "Fri -Ply@ Ultra-Flexlble Ply
6" or "RUBEROiDO Mop Smooth" or "RUBEROIDO Mop Smooth 1.5" or "RUBEROID@ Mop Plus Smooth", "Ruberold@ 20 Plus Smooth" or
"RUBEROID@ 20 Smooth", fully adhered with hot roofing asphalt.
Membrane: — Type G3'Trl-Ply@ BUR Granule Cap Sheet" or "GAFGLASO Mineral Surfaced Cap Sheet" or "GAFGLAS@ EnergyCap'"
Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt.
15. Deck: C-15/32
Incline: 1
Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polylsocyanurate mechanically fastened or adhered with
OMG Inc. "OlyBond Fastening System" or any UL Classified Insulation adhesive.
Barrier Board: — Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck@ Prime Roofboard" or
"DensDeck@ DuraGuard- Roofboard" or minimum 1/4-in. thick Untied States Gypsum Co. "SECUROCK@ Roof Board" (Type FRX-G) or
"SECUROCK@ Glass -Mat Roof Board" (Type SGMRX) mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any
UL Classified Insulation adhesive with butt joints in the barrier board products staggered a minimum of 6-in. from plywood deck joints.
Base Sheet: — One ply Type G2 "GAFGLAS@ #75 Base Sheet" or'Tri-Ply #75 Base Sheet" or "GAFGLAS@ #80 Ultima'" Base Sheet",
mechanically fastened.
Ply Sheet: — One or two plies Type G1 "GAFGLAS@ Ply 4" or "Tri-Ply 4" or "GAFGLAS@ Flex Ply 6" or Type G2 "GAFGLAS@ #75 Base
Sheet" or'Tri-Ply #75 Base Sheet" or "GAFGLAS@ #80 Ultima'" Base Sheet", fully adhered with hot roofing asphalt.
http://database.ul.com/cgi-binIXYVItemplateALISEXT/1 FRAMElshowpage.html?name=T... 3/22/2018
MIAMFDADE
nnANn-DADS CouNrY
•
PRODUCT CONTROL SECTION
11905 SW 26 Strect, Room 208
DEPARTIIIENT OF REGULATORY AND ECONONIIC RESOURCES (RER)
Miami, I•lorida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION
T (786)315-2590 F (796) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.eov/economnv
GAF
1 Campus Drive
Parsippany, NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having.lurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) .....
•
reserve the right to have this product or material tested for quality assurance purposes. If jliiS product of • .
material fails to perform in the accepted manner, the manufacturer will incur the expenWegf spph testiTig. •
and the AHJ may immediately revoke, modify, or suspend the use of such product or ntgtf,0:LVithin
their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by.Wgmi-Dade
County Product Control Section that this product or material fails to meet the requirenndAU%gC he ;""'
applicable building code. ...... ..
This product is approved as described herein, and has been designed to comply with the Tloiiga Building "
Code including the High Velocity Hurricane Zone of the Florida Building Code. :":':
DESCRIPTION: GAF Ruberoid"Modified Bitumen Roof System for Wood Deck. .•. •
.. . .. •
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state*..'.'
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been. filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. I f any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 14-1030.02 and consists of pages I through 67.
The submitted documentation was reviewed by Joree I... Acehn.
MIAMFOADE COUNTY
NOA No.: 1.5-1020.01
Expiration Date: 11/06/18
Approval Date: 02/15/18
i,age 1 or67
APPROVED ASSEMBLIES
Membrane Type:
SBS
Deck Type 11:
Wood, Insulated
Deck Description:
Min. 19/32" or greater plywood or wood plank secured 6 in. o.c. with 8d ring
shank nails to supports spaced 24 in. o.c. max.
System Type A(1):
All insulation layers are adhered to a mechanically attached anchor sheet.
Membrane is subsequently fully adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier:
FireOut"' Fire Barrier Coating, VersaShield' Fire -Resistant Roof Deck Protection
(optional)
or or VersaShield'' Solo"Fire-Resistant Slip Sheet.
Anchor sheet:
GAFGLASO 480 Ultima" Base Sheet, GAFGLAS' Stratavent'" Nailable Venting
Base Sheet, Ruberoid'w 20 Smooth, Ruberoid'" HW Smooth or Ruberoid" HW 25
Smooth base sheet mechanically fastened to deck as described below. • • • •
• •
Fastening
GAFGLAS*' Ply 4, Tri-Ply ' Ply 4 Ply Sheet. GAFGLAS"' Flexl`ly"'• 0
Option #1:
• • • •
GAFGLASI #75 Base Sheet, Tri-Ply'" #75 Base Sheet or any oC4hW pnchot'.. • ;
sheets attached to deck with approved annular ring shank nails W14 U rpips at a
fastener spacing of 9" o.c. at the lap staggered and in two rows 1?.;a C, in the.
field. ••••••
(Maximum Design Pressttre —45 psf. See Genera/ Linti'kdlatt 470.... ..
Fastening
GAFGLASifd Ply 4, Tri-Ply' Ply 4 Ply Sheet, GAFGLAS* Flexily • •6• • •
Option #2:
GAFGLASI #75 Base Sheet, Tri-Ply'"' #75 Base Sheet or any ol"• Me elnchor
sheets attached to deck with Drill -Tee'" # 12 Fastener, Drill-Tec A' # 14.1astenes 6f • • •
Drill-Tec" XHD Fastener and Drill-Tec"' 3" Steel Plate, Drill-_�ek" •A jcuTrac'.'.
Flat Plate or Drill-Tec'" AccuTrac`e Recessed Plate installed 12" o.c. in 3 row?..*.*
One row is in the 2" side lap. The other rows are equally spaced approximately
12" o.c. in the Geld of the sheet.
(Maximum Design Pressure —45 p. f. Secs General Limitation #7)
Fastening
GAFGLAS*' FlexPly'" 6, GAFGLAS" #75 Base Sheet, Tri-Ply'` #75 Base Sheet or
Option #3:
any of above anchor sheets attached to deck with approved annular ring shank
nails and tin caps at a fastener spacing of 9" ox. at the 4" lap staggered and in two
rows 9" o.c. in the field.
(Maxiutunt Desigit Pressure —52.S psf. See General Limitation #7)
Fastening
GAFGLAS"' #80 Ultima'" Base Sheet, Ruberoidw 20 Smooth, Ruberoid"Mop
Option #4:
Smooth base sheet attached to deck with approved annular ring shank nails and tin
caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c.
in the field.
(Maritnnm Design Pressure —60 psf. See General Limitation #7)
Fastening
GAFGLASI #75 Base Sheet, Tri-Ply* #75 Base Sheet or any of above anchor
Option #5:
sheets attached to deck with Drill-Tec"' 1/12 Fastener, Drill-Tec"' #14 Fastener or
Drill -Tee" XHD Fastener and Drill-Tec'" 3" Steel Plate, Drill-Tec" AccuTrac*
Flat Plate or Drill-Tec`" AccuTrac01 Recessed Plate installed 12" o.c. in 4 rows.
One row is in the 2" side lap. The other rows are equally spaced approximately 9"
o.c. in the Geld of the sheet.
(Marinutm Design Pressure-60 psf. See General Limitation #7)
MIAM101ADE COUNTY
"' • lllilillllllllllr
N OA No.: 15-1020.01
Expiration Date: 11/06/18
Approval Date: 02/15/t8
Page 9 of 67
Fastening Any of above anchor sheets attached to deck approved annular ring shank nails
Option #6: and 3" inverted Drill-Tec" insulation plates at a fastener spacing of 9" o.c. at the
4" lap staggered in two rows 9" in the field.
(Maxintunt Design Pressure —60 psf. See Cenral Limitation #7)
Fastening GA.FGLAS' #75 Base Sheet, Tri-Ply" #75 Base Shect or any of above anchor
Option #7: sheets attached to deck with Drill-Tec" 1112 Fastener, Drill-Tec"' 1114 Fastener or
Drill-Tec'" XHD Fastener and Drill-Tec" 3" Steel Plate, Drill-Tec"' Accu'l'rac'
Flat Plate or Drill-Tec"' AccuTraO Recessed Plate installed 8" o.c. in 4 rows.
One row is in the 2" side lap. The other rows are equally spaced approximately 9"
o.c. in the field of the sheet.
(Maximum Design Pressure —75 psf. See General Lindfution #7)
One or more layers of any of the following insulations
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard"" Polyiso Insulation, EnergyGuard"' Polyiso RA Insulation, ....
EnergyGuardf' Polyiso RN Insulation, EnergyGuard"' RA Composite Polyiso Insulation • 0000 •
Minimum 1" thick N/A • • • N/A • • • •
Structodek'" High .Density Fiber Board, EnergyGuard"' Perlite Recover Board • • •; • • •
Minimum''/:"thick N/A ••.. N/A.
EnergyGuard"' Perlite Roof Insulation "" •
Minimum %" thick N/A N/A:*.
.. .. . ..
Note: All insulation shall be adhered to the anchor sheet in full mopping of apprcweilebat asphalt •
within the EVT range and at a rate of 20-40 lbs./100 ft'. Please refer to Roofing Arpplica;ion • •
Standard RAS 117 for insulation attachment. Insulation listed as base layer only Shall The used•
only as base layers with a second layer of approved top layer insulation installed astfie final • • •
membrane substrate. Composite insulation panels maybe used as a top layer placed with the • • •
polyisocya nu rate side facing down. GAF requires either a ply of GAFGLAS'"' Stratavenf;'
Perforated Venting Base Sheet laid dry or a layer of EnergyGuard" Perlite Roof Insulation or
wood fiber overlay board on all polyisocyanurate applications.
Base Shect: (Optional) install one ply of GAFGLAS'"' #75 Base Sheet, Tri-Ply* 05 Base
Sheet, GAFGLASW #80 Ultima" Base Sheet, GAFGLAS"Ply 4, Tri-Plv' Ply 4
Ply Sheet GAFGLASW FlexPly" 6, Ruberoid' Mop Smooth, Ruberoid'"' Mop
Smooth 1.5, Ruberoid" Mop Plus Smooth, Ruberoid40 20 Smooth, Ruberoid"' H W
Smooth or Ruberoid'" H W 25 Smooth directly over the top layer of insulation.
Adhere with any approved mopping asphalt applied within the EVT range and at a
rate of 20-40 lbs./sq. (See General Limitation 44).
OR
GAFGLAS'"' Stratavent`"' Perforated Venting Base Sheet loose -laid dry.
Ply Sheet: (Optional, required over GAFGLAS'f' Stratavent" Perforated Venting Base Sheet
loose -laid dry)One or more plies GAFGLAS"' Ply 4, GAFGLAS"" FlexPly"' 6,
GAFGLASe #80 Ultima"' Base Sheet, Ruberoid''L Mop Smooth, Ruberoid" Mop
Smooth 1.5, Ruberoid°" Mop Plus Smooth, Ruberoid'" 20 Smooth adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate ol'20-40
lbs./sq.
MIAMI•DADECOUNTY NOA No.: 15-1020.01
Expiration Date: 11/06/18
Approval Date: 02/15/18
Page 10 of 67
Membrane: One or more plies of Ruberoid® 20 Smooth, RuberoidQ° 30 Granule, Ruberoid'
EnergyCap' 30 Granule FR, Ruberoid' 30 Granule FR, Ruberoid' 30 Plus
Granule FR, Ruberoid® Mop Smooth, Ruberoid' Mop Smooth 1.5, Ruberoid'
Mop Plus Smooth, Ruberoid® Mop Granule FR, Ruberoid4° Mop Granule, Tri-Ply®
SBS Granule Cap Sheet, Intec Flex PRF , Ruberoid' Mop Plus Granule,
Ruberoid® Mop Plus Granule FR fully adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of Approved asphalt at 60 lbs./sq.
2. GAFGLAS® Mineral -Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet
or GAFGLAS' EnergyCap' Mineral -Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq. 0000
3. TOPCOAT® Surface Seal SB or United Coatings'"' Surface Seat SB.Rgof Coaddl' •
applied in one or more coats at a minimum rate of 1.0 gal./sq. peleoat.' .' • j •.
OR *00:00
TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Mating • •
applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) folrowed by 0 • • • • •
TOPCOAT Membrane or United Coatings' Roof Mate TCM Pi oi4• • •
applied in one or more coats at a minimum rate of 1.0 gal./sq. pg;egaj� •
4. Fiber Aluminum Roof Coating. •„• • • •
Maximum Design
Pressure:
C; DADECOUNTY
See Fastening Options
NOA No.: 15-1020.01
Expiration Date: 11/06/18
Approval Date: 02/15/18
Page 11 of 67
WOOD DECK SYSTEM LIMITATIONS:
I A slip sheet is required with GAFGLASk' Ply 4 and GAFGLAS" FlexPly"' 6 when used as a
mechanically fastened base or anchor sheet.
2. Minimum 'A" DensDeck' Roof Board or'/i' Type X gypsum board is acceptable to be installed
directly over the wood deck.
GENERAL LIMITATIONS:
I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq., or mechanically
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell ....
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet• r...'
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 2A9 c.;or strip ....
mopped 8" ribbons in three rows, one at each side lap and one down the center of th* ghaot allow1114' :
a continuous area of ventilation. Encircling ofthe strips is not acceptable. A 6" bmalt sl ,41 be
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of ejtfiti,!rysteln sIal� •
be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited•tbowmaximan]
design pressure of -45 psf. `•: •': :0. '.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic lltcc?' ") valu(?of • •
275 IV., as tested in compliance with Testing Application Standard TAS 105. If tIV1'attter value, •
as field-tested, are below 275 Ibf. insulation attachment shall not be acceptable. • 0,...;.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachmilit is based
on a minimum fastener resistance value in conjunction with the maximum design value listed withl$.'.
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered
Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and scaled
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not
be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
MIAMMADE COUNTY
NOA No.: 15-1020.01
Expiration Date: 11/06/18
Approval Date: 02/15/18
Page 67 of 67
s
�•it
SECTION 1524
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with
the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402
govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the
following items should be addressed as part of the agreement between the owner ant the contractor. The owner's
initial in the designated space indicates that the item has been explained.
2.t' Renailing wood decks: When replacing roofing, the existing wood roof deck may have to, • • a • •
be renailed in accordance with the current provisions of Section R4403. (Thezogf�k is uslipiX
concealed prior to removing the existing roof system). ..•
.... .. . ......
4. _Exposed Ceiling: Exposed, open beam ceilings are where the undeMde of tttb roof decking,:• • •
can be viewed from below. The owner may wish to maintain the architectural agIVA
Y�lnce; t�erefgre, 000000
roofing nail penetration of the underside of the decking may not be acceptable jQrovides the option of .'
maintaining the appearance. .. .•o•;
• •
6. _Overflow scuppers (wall outlets): It is required that rainwater flows off so that fhb roof is
not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this
discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow
cup rs in actor nce with the requirements of Sections R4402, R4403 and R44 3.
--- (0 -5;- � y
g ign ture Date Contractor Signature Date
(ZI F ► IL tat S+- W a, Stwe,
Property Address Ft, 33 i 3 3
Revised on 7/9/2009 LD;07/01/2015;
Permit Number