Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REV-18-2540
BUILDING PERMIT APPLICATION BUILDING ❑ ELECTRIC Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 EP 4 18 FBC 20 Master Permit No. R F- 8" S — I Sub Permit No. E% — 2� T ROOFING Q!0_1REVISION ❑ EXTENSION ❑ RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP 1 /� �, CONTRACTOR DRAWINGS ` 0 JOB ADDRESS: 2-70 F_ Q t )� City: i Miami Shores County: Miami Dade Zip: Folio/Parcel#: 1\37pr©o?Q'570 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: " WNER: Name (Fee Simple Titleholder): -� ���� IlU \ S� e Phhoonee#: Address: N 27 O /\I V 5 1 Qh u City:\ A — 1 P 5 State: � ` Zip: Tenant/Lessee Name: Email CONTRACTOR: Company Name Address: 2� t✓ City: Qualifier Name: N "Y VUU State Certification or Registration M C cc State: e#: Phone#:'_1 O lJ '30 I Z2 one#: rtificate of Competency #: p: 3 __2� 1 110 I DESIGNER: Architect/Engineer: Phone#: Address: a— City: State: Zip: Value of Work for this Permit: Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition LII/Y 6IIG• Submittal Fee $ Permit Fee $ Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ CCF DBPR $ CO/CC $ Notary Double Fee $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. =�uSignaturer �J 0WNE or A EN The foregoing instrument was acknowledged before me this �Z day 20 by who i ersonally kno n to me or who has roduced as identification and who d NOT UBLIC: .?o~""�"�e° , ALBERT SEARA i� Notary Pub;lc - State of Florida Commission # FF 185218 Sign: o�� �q�:�' MY Comm. Expires Feb 24, 2019 ,-_� 0 Signature CONTRACTOR The foregoing in ument was acknowledged before me this day of J 20 by wh is personal mown me or who has produced Vwcl.�--.. ,. _ _ -gs Seal: \ \ Seal: .tsar Pi:''L ALBERT SEARA and who did k, A,'_ Notary Pub% - State of Florida Commission # FF 185218 LIC: "�, cc VY Comm. Expires Feb 24, 2019 F F Bonded through National Notary Assn. APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Slopea Roof System) Fitt In Specific Roof Assembly Components and Identft Manufacturer (If a component is not used, identify as"NA) System Manufacturer 4 - i 0 ZO , 0 NOA No.: G n F Design Wind Pressures, From RAS 128 or Calculations:Pm IJ2 , Pmax2: (1 ,7 Pmau3: 10 v Max Design Pressure, From the Specific WA _ S System: Deck L Gaugeltidckness: Slope: ° Z5� � 22— Anchor/Base Sheet & No. of Ply(s)-.�'l� Anchor/Base Sheet Fastener/Bor�dIng Material: r Insulation Base Layer. Base insulation Size and Thicimess: Fastener Spacing for Attachment Field: ' oc @ Lap, # Rows Z- C Perimeter 4 ' oc ® Lap, # Rows c_ @_L_ . Comer. @ Lap, # Rows [._ @! to oC -� Number of Fasteners Per Insulation Hoard • I Field Perimeter Comer ---I i • • Illustrate Components Noted aM! .:. Details as Applicable: • • •; • •:.;. Woodbiocking, Gutter, Edge tdrMhation, Stripping, Flashing, Continuous C11M * Cant .: Strip, Base Flashing, Counter- • was*hing, ; • • • Coping, Etc. • • • • • • tom: Mean Roof Height, Parapet. Alght, • • Height of Base Flashing, Componept, Arterial, Material Thickness, Fastener Type, rarener•• Spacing or Submit Manufacturers.DetVs that.:..... Comply with RAS 111 and Chapter•tf3° • Base Insulation Fastener/Bonding Material: -"A A/� Top Insulation Layer. Top Insulation Size and Thickness: 1 6e Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Pty(s):vt7e -W- Base Sheet Fastener Mdal: -�`�r Ply Sheat(s).d, No. of Ply(s): i SAP 2 10�8 Ply Sheet Fastener/Bonding Material: r/ Top Ply-1( 191f44 (A.0 O(N12 Top Ply Fastener/ Bondi ria1: Surfacing: -EVISIO FT.I tJ(T Parapet 2 -Lc) I I He,aht FT. 'u3 Mean Roof /Ju41 S HHeightc0& It C .J L�� A f? . 1 U J W n 0 w c• z p f� a I w `" U i Q j i h 0J L C n o c • CJ L • MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy MIAMI•DADE GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dgde County M!% Product Control Section to be used in Miami Dade County and other areas where allowbX the Authority Having Jurisdiction (AHJ). • • • • •. • This NOA shall not be valid after the expiration date stated below. The Miami -Dade Munl Product • Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami ode Count}'. • reserve the right to have this product or material tested for quality assurance purposes.lLftbis proA t oY• material fails to perform in the accepted manner, the manufacturer will incur the expexsa of such;g1*t.ng and the AHJ may immediately revoke, modify, or suspend the use of such product o4malorial within. their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by N;iami� ado, County Product Control Section that this product or material fails to meet the requiremeal� of the applicable building code. . ".'. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Ruberoid® Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 14-1030.02 and consists of pages 1 through 67. The submitted documentation was reviewed by Jorge L. Acebo. APPROVED NOA No.: 15-1020.01 Expiration Date: 11/06/18 Approval Date: 02/15/18 Page I of 67 ROOFING SYSTEM APPROVAL Category Roofing Sub -Category: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -105 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description • •-T� .... GAFGLAS® Ply 4 39.37" ASTM D2178 Smooth surfaced aspKalti� ply sDeQt••• ..... • .' (1 meter) Wide reinforced with fibeWjii%mat. "" • Tri-Ply® Ply 4 Ply Sheet 39.37" ASTM D2178 Smooth surfaced aspWa c ply sheet 0 (1 meter) Wide reinforced with fiberglass mat.. ••0 • • GAFGLAS® 39.37" ASTM D2178 Smooth surfaced atpDAktc ply she4.. 0000, : . FlexPly"' 6 (1 meter) Wide reinforced with fibe'rgf&s mat.*-:. • • • 0 .. • 0 0 • GAFGLAS® #75 Base Sheet 39.37" ASTM D4601 ...... . Smooth asphaltic base or base/ply sheet '. (1 meter) Wide reinforced with filergjass mat* . Tri-Ply' #75 Base Sheet 3937" ASTM D4601 Smooth asphaltic base of base/ply. heet : • •' •; (1 meter) Wide reinforced with fiberglass mat. ' • • GAFGLAS® #80 Ultima M Base 39.37" ASTM D4601 Smooth asphaltic base or base/ply sheet Sheet (1 meter) Wide reinforced with fiberglass mat. GAFGLAS® Stratavent® 39.37" ASTM D4897 Smooth surfaced asphaltic perforated Perforated Venting Base Sheet (1 meter) Wide venting base sheet reinforced with fiberglass mat. GAFGLAS® Stratavent® 39.37" ASTM D4897 Smooth surfaced asphaltic nailable venting Nailable Venting Base Sheet (1 meter) Wide base sheet reinforced with fiberglass mat. Bottom side surfaced with granules. Ruberoid® HW 25 Smooth 39.37" ASTM D6163 Smooth surfaced torch applied SBS base (1 meter) Wide or ply sheet reinforced with a fiberglass mat. Ruberoid® HW Smooth 39.37" ASTM D6164 Smooth surfaced torch applied SBS base (1 meter) Wide or ply sheet reinforced with a polyester mat. Ruberoid® HW Granule 39.37" ASTM D6164 Granule surfaced torch applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid® HW Granule FR 39.37" ASTM D6164 Fire retardant granule surfaced heat - (I meter) Wide welded SBS cap sheet reinforced with a polyester mat. Ruberoid® HW Plus Granule 39.37" ASTM D6164 Granule surfaced torch applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid® HW Plus Granule 39.37" ASTM D6164 Fire retardant granule surfaced torch FR (1 meter) Wide applied SBS cap sheet reinforced with a polyester mat. NOA No.: 15-1020.01 Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 2 of 67 Test Product Product Dimensions Specification Description Ruberoid® EnergyCap' HW 1 meter ASTM D6164 Fire retardant granule surfaced heat - Plus Granule FR (39.37") Wide welded SBS cap sheet reinforced with a polyester mat. Cap sheet is factory coated with TOPCOAT® EnergyCote' Elastomeric Coating. Ruberoid® Torch Smooth 39.37" ASTM D6222 Smooth surfaced torch applied APP base (I meter) Wide or ply sheet reinforced with a polyester mat. Tri-Ply® APP Smooth 39.37" ASTM D6222 Smooth surfaced torch applied APP cap, Membrane (1 meter) Wide base or ply sheet reinforced with.' • • .... polyester mat. 0�. Ruberoid® Torch Granule 39.37" ASTM D6222 Granule surfaced torah applied ArP dap (1 meter) Wide sheet reinforced wittra poilyester mV. Tri-Ply® APP Granule Cap 39.37" ASTM D6222 Granule surfaced tgtCh lied APP cap Sheet (1 meter) Wide sheet reinforced with' 111by ester mat. Ruberoid® Torch Plus Granule 39.37" ASTM D6222 •....• 0090 Fire retardant granule strAaced taft FR (1 meter) Wide applied APP cap slVetr0tnforced 4th a Ruberoid® EnergyCap' 39.37" ASTM D6222 polyester mat. 0 ; 0 0 Fire retardant granujg surfaced torch Torch Plus Granule FR (1 meter) Wide applied APP cap sheet reinforces Wilk a polyester mat. Cap sheet is factory coated with TOPCOAT® EnergyCote' Elastomeric Coating. Ruberoid® EnergyCap' 39.37" ASTM D6222 Fire retardant granule surfaced torch Torch Granule FR (I meter) Wide applied APP cap sheet reinforced with a polyester mat. Cap sheet is factory coated with TOPCOAT® EnergyCote' Elastomeric Coating. Ruberoid® 20 Smooth 39.37" ASTM 136163 SBS polymer -modified asphalt base or ply (1 meter) Wide sheet reinforced with a fiberglass mat. Ruberoid® 30 Granule 39.37" ASTM D6163 Granule surfaced mop applied SBS cap (I meter) Wide sheet reinforced with a fiberglass mat. Ruberoid® 30 Granule FR 39.37" ASTM 136163 Fire retardant granule surfaced mop (1 meter) Wide applied SBS cap sheet reinforced with fiberglass mat. Ruberoid® 30 Plus Granule FR 39.37" ASTM D6163 Fire retardant granule surfaced mop (1 meter) Wide applied SBS cap sheet reinforced with fiberglass mat. Ruberoid® Mop Granule 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. Tri-Ply® SBS Granule Cap 39.37" ASTM D6164 Granule surfaced mop applied SBS cap Sheet (I meter) Wide sheet reinforced with a polyester mat. Intec Flex PRF 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (I meter) Wide sheet reinforced with a polyester mat. Ruberoid® Mop Smooth 39.37" ASTM 136164 Smooth surfaced mop applied SBS base (1 meter) Wide sheet reinforced with a polyester mat. NOA No.: 15-1020.01 Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 3 of 67 Test Product Product Dimensions Specification Description Ruberoid® Mop Smooth 1.5 39.37" ASTM D6164 Smooth surfaced mop applied SBS base (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid® Mop Plus Smooth 39.37" ASTM D6164 Smooth surfaced mop applied SBS base or (1 meter) Wide ply sheet reinforced with a polyester mat. Ruberoid® Mop Plus Granule 39.37" ASTM D6164 Granule surfaced mop applied SBS cap (1 meter) Wide sheet reinforced with a polyester mat. Ruberoid' Mop Plus Granule 39.37" ASTM D6164 Fire retardant granule surfaced mop FR (1 meter) Wide applied SBS cap sheet reinforced with a polyester mat. Ruberoid® EnergyCap' Mop 39.37" ASTM D6164 Fire retardant granule surfaced rrgdp • • Plus Granule FR (1 meter) Wide applied SBS cap sheet rei�forcedWAM a ••••.. polyester mat. Caput is factory gated • with TOPCOAT® Prwr ycote"` Elastomeric Coating.. • • .. . • • • •.. Ruberoid® Mop Granule FR 39.37" ASTM D6164 Fire retardant granufe sift faced mop.' 00000 + (1 meter) Wide ...... applied SBS cap sil�et re%forced SA#?a ..%oo .... polyester mat. . 0000 ...... Ruberoid® EnergyCap�"" 30 39.37" ASTM D6163 Fire retardant granule SuGfacedmop •, Granule FR (1 meter) Wide applied SBS cap sheet aeinforctdv;k a 0 "' • • fiberglass mat. Capsheet is facVvy coated ' with TOPCOAT' EnergyCote*'••'.' • Elastomeric Coating. GAFGLAS' Mineral -Surfaced 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Cap Sheet (1 meter) Wide reinforced with fiberglass mat. Tri-Ply' BUR Granule Cap 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Sheet (1 meter) wide reinforced with a fiberglass mat. GAFGLAS' EnergyCap' 39.37" ASTM D3909 Granule surfaced asphaltic cap sheet Mineral -Surfaced Cap Sheet (1 meter) Wide reinforced with fiberglass mat. Cap sheet is factory coated with TOPCOAT' EnergyCote' Elastomeric Coating. TOPCOAT' Membrane 1, 5 or 55 gallons ASTM D6083 Water based elastomeric coating. United Coatings' Roof Mate 1, 5 or 55 ASTM D6083 Water -based elastomeric coating TCM Coating Gallons TOPCOAT' 5 or 55 gallons ASTM D6083 Surface Seal SB United Coatings' Surface Seal 5 or 55 Gallons ASTM D6083 SB Roof Coating TOPCOAT' MB Plus United Coatings' Roof Mate MB Plus Coating 5 or 55 gallons 5 or 55 Gallons Proprietary Proprietary Solvent based thermoplastic rubber sealant designed to protect and restore aged roof surfaces and to increase roof reflectivity. Solvent -based thermoplastic rubber sealant designed to protect and restore aged roof surfaces and to increase roof reflectivity. Water based, low VOC primer used to block asphalt bleed -through. Water based, low VOC primer designed to block asphalt bleed -through. NOA No.: 15-1020.01 =MIAMIE-DADE COUNTY Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 4 of 67 Product Dimensions FireOut' Fire Barrier Coating 5 or 55 gallons Flex Seal' 1, 5 gallons or 1 qt. tube VersaShield® Fire -Resistant 12" x 100' rolls Roof Deck Protection VersaShield® Solo— Fire- 42" roll wide, Resistant Slip Sheet 100 ft. Matrix- 102 SBS Membrane 3, 5 or 55 gallons Adhesive APPROVED INSULATIONS: Product Name EnergyGuardTM Polyiso Insulation EnergyGuard' Tapered Polyiso Insulation EnergyGuard' RA Polyiso Insulation EnergyGuard— RH Polyiso Insulation EnergyGuard' RH Tapered Polyiso Insulation EnergyGuard' RN Polyiso Insulation EnergyGuard' Perlite Recover Board EnergyGuard' Perlite Roof Insulation Test Product Specification Description Proprietary Low VOC, water -based fire barrier coating. TAS 139 Solvent -based elastomeric sealant. ASTM D226 Non -asphaltic fiberglass -based underlayment and /or fire barrier. ASTM D146, Non -asphaltic, fire resistant fiberglass D828, D4869, underlayment D6757 •••• ASTM D3019 Fiber reinforced rubberized cold Tapoie$ adhesive for modifiedtitulhen roof• • - • •... systems. • • • • • • • • •••• Table 2 • • ...... Product Description oNaFfiufactuter (With Currenb•NbA� Polyisocyanurate foam insulation GAF Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Perlite recover board Perlite insulation board EnergyGuard' RA Composite Polyiso Polyisocyanurate foam insulation Insulation with high density fiberboard or permalite Structodek® High Density Fiberboard Roof High density fiberboard Insulation SECUROCK® Gypsum -Fiber Roof Board Gypsum board SECUROCK® Glass -Mat Roof Board Gypsum board DensDeck® Roof Board Gypsum board DensDeck® Prime Roof Board Gypsum board APPROVED GAF GAF GAF GAF GAF GAF GAF GAF Blue Ridge Fiberboard, Inc. United States Gypsum Corp. United States Gypsum Corp. Georgia-Pacific Georgia-Pacific NOA No.: 15-1020.01 Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 5 of 67 •••••• ..000: .004 o: APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Drill-TecT" #12 Fastener Phillips head, modified #12 x 8" GAF buttress thread, pinch Max. Length point, carbon steel fastener #3 Phillips for use in steel or wood head. Goo* decks. With CR-10 . ' .... ...... coating. Available with a • • Goo • • • pinch point or drill point. so*:** • • • • • • • • • • 2. Drill-Tec'"' #14 Fastener Truss head, self -drilling, # 14 x 16" """ GAF ' :Goes: pinch point, high thread Max. Length -**so- ..... o . o o ..... fastener for use in steel, #3 Phillips ...... ..... • ..... wood or concrete decks. head. .... .. ..' ...... 3. Drill-Tec" XHD Fastener Truss head, self -drilling, #15 x 16" ...... GAF • •o pinch point, high thread Max. Length • • • • • • fastener for use in wood or #3 Phillips ' steel decks. Carbon steel head. so0 so0o o 6 extra heavy duty fastener •• • used in steel decks. 4. Drill-Tec' 3" Steel Plate Round Galvalume® steel 3" Round GAF stress plate with reinforcing ribs and recessed for use with Drill- Tec'M fasteners. 5. Drill-Tec`' 3" Standard Galvalume® coated steel 3" Round GAF Steel Plate stress plate for use with approved Drill-Tec' fasteners. 6. Drill-Tec' ASAP 3S Drill-Tec' #12 fastener #12 x 8" GAF with Drill-Tec' 3" Max. Length Standard Steel Plate. #3 Phillips head with 3" Round plate 7. Drill-Tec' AccuTrac®Flat A2-SS aluminized steel 3" square; GAF Plate plate for use with Drill- .017" thick Tec" fasteners.. 8. Drill-Tec' AccuTraca Galvalume® steel plate 3" square; GAF Recessed Plate with recess for use with .017" thick. Drill-Tec' fasteners. 9. Drill-TecT" 3 in. Ribbed Round Galvalume® plated 3" Round GAF Galvalume Plate (Flat) steel stress plate with reinforcing ribs for use with Drill-Tec' fasteners. NOA No.: 15-1020.01 Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 6 of 67 EVIDENCE SUBMITTED: Test Aeencv Test Identifier Description Date Factory Mutual Research Corp. 3001276 FMRC 4470 01/28/99 3010215 FMRC 4470 03/01/01 3029832 FMRC 4470 05/11/07 3036980 FMRC 4470 08/14/09 3034312 FMRC 4470 04/09/09 3040738 FMRC 4470 05/18?", 3042887 FMRC 4470 .•. 11/147ff 3046081 FMRC 4470 •,, 02/;�;1.3,- 1139A8.AM FMRC 4470 ... ; .. 09/04/9.7 3D4Q2.AM FMRC 4470 .... 04/i0/9'L OD 1 A8.AM FMRC 4470 • • • • 04/91 798' Factory Mutual Research Corp. 797-03221-267 FMRC 4470 ";"; 09/24V7- 797-10228-267 FMRC 4470 01 /1 SM 797-04694-267 FMRC 4470 • ; 06/1 7/09. 797-03825-267 FMRC 4470 07/Z4MF- RR203450 FMRC 4470 '..' 12/O441S FM Letter FMRC 4470 04/14A13 FM Letter FMRC 4470 09/15/15 Underwriters Laboratories R1306 UL 790 01/25/18 Trinity Engineering 4483.04 97-1 TAS 114 06/06/97 IRT-ARCON Inc. 02-005 TAS 114 03/01/02 02-014 TAS 114 04/08/02 01-039 TAS 114 03/01/02 Trinity I ERD C8500SC.11.07 ASTM D6862 11/30/07 G30250.02.10-2 ASTM D6222 11/11/10 G30250.02.10-3-R2 ASTM D3909 06/03/15 G31360.03.10 ASTM D6164 03/31/10 G32520.06.11 ASTM D1876 06/28/11 G33470.01.11 ASTM D6164 01/13/11 G34140.04.11-2 ASTM D6163 04/25/11 G34140.04.11-4-R2 ASTM D4601 6/4/2015 G34140.04.11-5-R3 ASTM D4897 6/4/2015 G36780.07.1I-R1 TAS 114-J 07/18/11 G40620.07.12-2 ASTM D6222 07/17/12 G40630.01.14-1 ASTM D6163 01/06/14 G40630.01.14-2A ASTM D5147 01/07/14 G40630.01.14-2A-1-Rl ASTM D6164 04/10/14 G40630.01.14-2B-R1 ASTM D6164 01/16/15 G40630.01.14-2C ASTM D6164 01/07/14 G40630.03.14 ASTM D5147 03/06/14 G43190.03.14-1 ASTM D5147 03/06/14 G43190.03.14-2 ASTM D5147 03/06/14 G43190.05.14-R1 ASTM D5147 05/20/14 NOA No.: 15-1020.01 Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 7 of 67 EVIDENCE SUBMITTED: (CONTINUED) Test Agency Test Identifier Description Trinity ERD G43190.11.13-1 ASTM D6222 G43610.01.14 ASTM D5147 G46160.02.15 ASTM D6163 G46160.02.15-213-1 ASTM D6163 G46160.03.15 ASTM D6163 G46160.09.14-2A ASTM D5147 G46160.09.14-3A ASTM D6164 G46160.09.14-313 ASTM D6164 G46160.09.14-3C ASTM D5147 G46160.12.14-3E ASTM D6164 G6850.08.08 ASTM D6163 G6850.08.08-R1 ASTM D6164 G6850.10.08 ASTM D6222 G6850.11.08 ASTM D6222 SC6870.08.14-R1 ASTM D3909 PRI Construction Technologies LLC. GAF-122-02-01 TAS 139 GAF-245-02-01 ASTM D6083 GAF-276-02-01 Rev ASTM E2178 ASTM D6083 GAF-306-02-01 ASTM E96 GAF-314-02-01 ASTM D2178 GAF-315-02-01 ASTM D2178 GAF-369-02-01 ASTM C1289 GAF-434-02-03 TAS 114-J GAF-434-02-04 TAS 114-J GAF464-02-01 ASTM C 1289 GAF-498-02-01 ASTM D6083 GAF499-02-01 ASTM D6083 GAF-500-02-01 ASTM D6083 GAF-559-02-01 TAS 117(B) GAF-559-02-04 ASTM D1876 GAF-559-02-05 ASTM D1876 GAF-559-02-06 TAS 114(H) GAF-559-02-07 ASTM D903 GAF-559-02-08 ASTM D903 GAF-559-02-09 ASTM D903 GAF-559-02-11 TAS 114-J GAF-559-02-12 TAS 114-J GAF-559-02-13 TAS 114-J GAF-559-02-14 TAS 114-J GAF-559-02-15 TAS 114-J GAF-559-02-16 TAS 114-J GAF-559-02-18 TAS 114-J GAF-559-02-19 TAS 114-J Date 11/15/13 01 /22/14 02/12/15 02/09/16 03/11/15 09/99t" 09/091" 09/094" - 09/09/1.*4 12/29/14 08/01%&' 04/14;1.1• • 10/06/v8 02/17/d9 09/Q4#4 • 051977W . 06/16710 01 /04/ 11 07/07/ 11 08/23/11 08/23/ 11 10/22/ 12 09/06/13 09/06/ 13 02/06/ 14 09/16/16 03/12/14 03/12/14 09/30/14 10/01/14 10/15/14 10/02/14 10/02/14 10/02/14 10/02/14 10/14/14 10/14/14 10/15/14 10/15/14 10/15/14 10/15/14 10/15/14 04/16/15 NOA No.: 15-1020.01 MAMMA Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 8 of 67 Membrane Type: SBS Deck Type 1I: Wood, Insulated Deck Description: Min. 15/32" thick plywood or wood plank secured 6 in. o.c. with 8d ring shank nails to supports spaced 24 in. o.c. max. System Type A(5): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. •••• All General and System Limitations shall apply. • Fire Barrier: . . .... FireOut' Fire Barrier Coating, VersaShield® Fire -Resistant SjigSteet or. • • ...... • • (optional) VersaShield Solorra Fire -Resistant Slip Sheet. ...... '.;..' ....:. Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, Ruberotj'4'0. 20 Smooth pr • • • • GAFGLAS® Stratavent® Nailable Venting Base Sheet is sectire" gS desc4b0d.' .. . • below. ...... .... ..... Fastening Miami -Dade County Approved min. 12 ga. annular ring sh n;DSand mn,1- �,' • Option #1: 5/8 in. diameter tin caps are spaced 8 in. o.c. in the min. 4 in, witIdLnchor sheet ....:. side laps and 8 in. o.c. in the field of the sheet in two stagge ped rokys. • (Maximum Design Pressure —45 psf, See General Limitation W7) • • • • • • Fastening • • Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1- Option #2: 5/8 in. diameter tin caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure —52.5 psf, See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill-Tec'T' 3 in. Standard Steel Plates, Drill-Tec' Option #3: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure —52.5 psf, See General Limitation #7) Fastening Drill-Tec— #14 Fasteners and Drill-Tec'T' 3 in. Standard Steel Plates, Drill-Tec'T" Option #4: AccuTrac® Flat Plates or Drill-Tec— 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure —67.5 psf, See General Limitation #7) Fastening Drill-Tec— #14 Fasteners and Drill-Tec— 3 in. Standard Steel Plates, Drill-Tec'-" Option #5: AccuTrac® Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure —75 psf, See General Limitation #7) One or more of any of the following insulations. Base Layer Insulation Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuard" Polyiso Insulation, EnergyGuard" Tapered Polyiso Insulation, EnergyGuard" Ultra Polyiso Insulation, EnergyGuard"' RH Polyiso Insulation, EnergyGuard" RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A NOA No.: 15-1020.01 Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 19 of 67 Top Layer Insulation Insulation Fasteners Fastener (Table 3) Density/ft2 EnergyGuard'" Perlite Roof Insulation Minimum %" thick N/A N/A StructodeV High Density Fiber Board Minimum'/2" thick N/A N/A SECUROCK® Gypsum -Fiber Roof Board, DensDeck® Prime Minimum'/4" thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the E•V I': • range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Staggarl RAS.11'7 for • � • • • insulation attachment. ...... .... ' ...... Base Sheet: Install one or more plies of Ruberoid® 20 Smooth adhered with a ny approved� • • • • mopping asphalt applied within the EVT range and at a rate'tl"Q-10 lbs f sq,. • • • (See General Limitation #4). ...... .... ..... ' Membrane: Ruberoid® 30 Granule FR, Ruberoid® 30 Plus Granule FR, •j&&rQid® Mop • • • Granule, Tri-Ply® SBS Granule Cap Sheet, Intec Flex PRF, Rub*eraid® Mop ....:. Granule FR, Ruberoid® Mop Plus Granule FR, Ruberoid® EtierVCap— M•op • • • • Plus Granule FR, Ruberoid® EnergyCap— 30 Granule FR GWLf1Sv NQ Mral;- • Surfaced Cap Sheet, Tri-Ply'BUR Granule Cap Sheet or GAFGLAS® " ' EnergyCap'T' Mineral -Surfaced Cap Sheet adhered with any approved mopping asphalt applied within the EVT range and at a rate of 20-401bs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. TOPCOAT® Surface Seal SB or United Coatingsn' Surface Seal SB Roof Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. OR TOPCOAT® MB Plus or United Coatings' Roof Mate MB Plus Coating applied at a minimum rate of 1.0 gal./sq.(to be used as a primer) followed by TOPCOAT® Membrane or United Coatings' Roof Mate TCM Coating applied in one or more coats at a minimum rate of 1.0 gal./sq. per coat. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fastening Options NOA No.: 15-1020.01 Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 20 of 67 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® F1exPly— 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum'/4" DensDeck® Roof Board or Type X gypsum board.is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached ip coiyplianc0 W tl; Product Control Approval guidelines. All other layers shall be adhered in a full•roopping of. .. approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., o1b mmimnicali}•: • • • attached using the fastening pattern of the top layer • • • • • • • 3. All standard panel sizes are acceptable for mechanical attachment. When applied iri Approved'. asphalt, panel size shall be 4' x 4' maximum. • • • 4. An overlay and/or recovery board insulation panel is required on all applications pvgr Closed q,($J • foam insulations when the base sheet is fully mopped. If no recovery board is us Aqw base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles 20 o.c.; omtrip• ***Poe mopped 8" ribbons in three rows, one at each side lap and one down the center of tfesheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" bPeak*shall placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lb£, as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 Ibf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 15-1020.01 Expiration Date: 11/06/18 Approval Date: 02/15/18 Page 67 of 67 TGFU.R1306 - Roofing Systems � 5 20. Deck: C-1S/32 Inclines 1 Page 1 of 1 Base Sheets — One ply Type G2 "GAFGLAS® #7S Bate Sheet" or "Tri-Ply® #75 Base Sheet" mechanically fastened, Insulatlon (Optlonal)i — Any thickness or combination: perllte or wood fiber or glen fiber or polyliocyanurata, mechanically fastened or _hot mopped or adhered with OMG Inc. "Oly9ond Fastening System" or any UL Classified insulation adhesivs, Base Sheets — One or more plies "RUeEROIDO 20 Smooth", "Ruberoidg 20 Pius Smooth" or "RUSEROID® MW 2S Smooth", mechanically fastened or fully adhered with hot roofing asphalt, Cap Sheets — Type G3 "GAFGLASe Mineral Surfaced Cap Sheet" or "Tri-Piye BUR Granule Cap Sheet" or "GAFGLAS® EnarpyCep'"" Mineral -Surfaced Cap Sheet". • • •••• •••••• • •••• • •• ••••• •••••• •••• ••••• •• •• •••• •••••• • • • • • •••••• ••+• •• • • • oe •••••• • • • • • • • • •••••• • •• • • • 00 http://database.ul-com/cgl-bin/XYV/template/LISEXT'/IFRAMElshowpage,html?namo-TGFU,R1306&ccnsho.,, 5/16/2018