Loading...
MCC-18-3710Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Permit No.: MCC-12-18-3710 Permit Type: Mechanical - Commercial Work Classification: Alteration Permit status: Approved Issue Date: 01/09/2019 1 Expiration: 06/17/2019 Location Address Parcel Number 9005 BISCAYNE BLVD, Miami Shores, FL 33138 1132060110060 Contacts TD MIAMI SHORES LLC Owner LENNOX NATIONAL ACCOUNT SERVICES Contractor 326 E 1 ST, HINSDALE, IL 60521 LLC Business: 6303700142 JAMES DILKS 3511 NE 22 AVE, FORT LAUDERDALE, FL 33308 Business: 9545375544 Mobile: 5135688286 ti Description: REPLACEMENT OF HVAC UNITS (12 TON Valuation: $ 24,325.00 on Requests: Inspection 4949 CONDENSER FOR UNIT#1) Total Sq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $15.00 DBPR Fee $10.95 DCA Fee $7.30 Education Surcharge $5.00 Permit Fee $679.75 Scanning Fee $9.00 Technology Fee $18.24 Total: $795.24 Payments Date Paid Amt Paid Total Fees $795.24 Check # 10632 12/18/2018 $50.00 Check # 10634 01/08/2019 $745.24 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS PFFIDAVIT: I ce 'ify that all th foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constr ction d z i therm r authorize the above named contractor to do the work stated. _ Authorized Signature: Owner) / Applicant / Contractor / Agent Date January 08, 2019 Page 2 of 2 Miami Shores Village Building Department C� �/- 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION BUILDING ❑ ELECTRIC ❑ ROOFING 4p T FBC 2014 Master Permit No. M W 19 — � 10 Sub Permit No. ❑ REVISION ❑ EXTENSION RENEWAL PLUMBING M MECHANICAL PUBLIC WORKS ❑ CHANGE OF CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 9005 Biscayne Blvd City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 11-3206-011-0060 Is the Building Historically Designated: Yes NO no Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): SMSB LLC & TD Miami Shores LLC Phone#: 630-370-0142 Address:326 E First Street City: Hinsdale State: IL Zip: 60521 Tenant/Lessee Name: TD Bank Phone#: Email: CONTRACTOR: Company Name: Lennox NAS Phone#: 954-537-5544 Address. 3511 NE 22 Avenue City: Fort Lauderdale State: FL Zip: 33308 Qualifier Name: James L Dilks Phone#: 513-568-8286 State Certification or Registration #: CAC1819182 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ City: State: Zip: Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration M New Description of Work: Replacement of HVAC units ❑ Repair/Replace ❑ Demolition Specify color of color thru tile: Submittal Fee $ �� Permit Fee $ L 1 c5CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ r (aevised02/24/2014) . Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City Zip State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature A� W4—vdn OWNER or AGENT The foregoing instrument was acknowledged before me this 2 day of A,4t116&,, , 20 TJ,- • by -3*P J .e ,,) M . S Ljm ro ,vho is personally known to me or who has produced f L 2) 's as identification and who did take an oath. Signature 44;�— CONTRACTOR The oregoing instrument was acknowledged before me this T17 day of �� . 20 ( , by DLf o is personally k to me or who has produced identification and who did take an oath. as NOTARY PUBLIC: NOTARY PUBLIC: n 111111 Sign• + Sign:' Print: ` C3''' eox 'J H79 Print:t1-1� Q ;• �Q j� .0 Notary Public State of FWft Seal: Seal: Marie C Bessette My Cormimesm GG 206230 Expres 04116=22 Pueoc' 11111�% APPROVED BY Pins Examiner Zoning Structural Review Clerk (Revised02/24/2014) Property Search Application - Miami -Dade County Page 1 of 1 rc OFFICE Summary Report Property Information Folio: 11-3206-011-0060 Property Address: 9005 BISCAYNE BLVD Miami Shores, FL 33138-3221 Owner SMSB LLC TD MIAMI SHORES LLC Mailing Address 326 E FIRST ST HINSDALE, IL 60521 USA PA Primary Zone 6200 COMMERCIAL - ARTERIAL Primary Land Use 2313 FINANCIAL INSTITUTION: OFFICE BUILDING Beds / Baths / Half 0/0/0 Floors 0 Living Units 0 Actual Area 5,339 Sq.Ft Living Area 5,339 Sq.Ft Adjusted Area 4,795 Sq.Ft Lot Size 27,731 Sq.Ft Year Built 2012 Assessment Information Year ...........___ Land Value ................. Building Value 20181 2017 _._. $1,525,205 $1,525,205 _... ..® $2,474,7951 $2,874,795 2016 $1,525,205 _ __..._.......... ..._._ $2,874,795 XF Value $0 $0 $0 Market Value $4,000,0001 $4,400,000 $4,400,000 Assessed Value $4,000,000 $4,400,000 $4,400,000 Benefits Information Benefit Type _. _...._...._2018 .._ 2017 2016 ........... _ ... ..__........ Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 6 53 42 ASBURY PARK PB 4-110 BEG 478.01 FTW OF SE COR LOT 5 RUN W219.07FT ALG N R/W/L NE 90TH ST N12.20FT TO E RM//L BISC BLVD TH Generated On : 12/18/2018 Taxable Value Information 2018i 2017' 2016 County Exemption Value $0 $0 $0 Taxable Value i $4,000,000 $4,400,0001 $4,400,000 School Board Exemption Value $0 ..._.. ..............._.._._................_...___._._ _ Taxable Value $4,000,000 $0 $4,400,000 $0 _...._.._............................................. . $4,400,000 City Exemption Value $0 $0 $0 Taxable Value $4,000,000 $4,400,000 $4,400, ....................... Regional Exemption Value $0 __ ___._................;.............._................___...._......_.._....._._._____..__ Taxable Value $4,000,000 $0 $4,400,000 $0 .._._____ _........ $4,400,000 Sales Information Previous OR Book - Price Qualification Description Sale Page 07/19/2018 $5,500,000 31071-4851 Qual by exam of deed 04/05/2017 $4,800,000 30491-2360 Partial interest _.._........................ 03/30/2017 $4,800,000 _ _... 30478-0402 _......_ Partial interest Non -market financing or assumption 03/06/2015 $5,555,600 29541-3687 of lease The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: https://www.miamidade.gov/propertysearch/ 12/18/2018 Detail by Entity Name Page 1 of 1 F iori DE�atft„ent of ;tat: 4 Jti � Department of State I 1y151 n of (:Ur.OCatjojjS / SeF rch Records / Deta ! By Documeni Number / Detail by Entity Name Florida Limited Liability Company TD MIAMI SHORES, LLC Filing Information Document Number L18000151928 FEI/EIN Number NONE Date Filed 06/20/2018 State FL Status ACTIVE Principal Address 326 E FIRST ST HINSDALE, IL 60521 Mailing Address 326 E FIRST ST HINSDALE, IL 60521 Registered Agent Name & Address CORPORATION SERVICE COMPANY 1201 HAYS STREET TALLAHASSEE, FL 32301-2525 Authorized Person(s) Detail Name & Address I Title MGR SWANSOM, STEVEN M 326 E FIRST ST HINSDALE, IL 60521 Annual Reports No Annual Reports Filed Document Images 01,120/2018 — Flo,dla Limited Lii.!LIitvl View image in PDF ;otr;at http://search. sunbiz. org/Inquiry/CorporationSearchISearchResultDetail?inquirytype=Entit... 12/ 18/2018 RICK SCOTT, GOVERNOR JONATHAN ZACHEM, SECRETARY FI dda STATE OF FLORIDA DEPARTMENT OF BUSINESS. -AND --PROFESSIONAL REGULATION CONSTRUCTrON LNDUSTRY:--ICENSING BOARD THE CLASS A AIR CO►NDITIONI-N��CONTRACT40R HEREIN�IS,�CERTIFIED UNDER THE PROVISI NSA -OF; CHAPTER�489, FLORIDA §TATUTES n. �DILKS; JAMES'LERO`Y�II't LENN,' OX NAT O.NAL:A000UNT SERVICES=LLC 1435.11,;NE22ND=A J"" F,QRT+LAUD.ERDALE .,FL 330 f Always verify licenses online at MyFloridaUcense.com Do not alter this document in any form. This is your license. It is unlawful for anyone other than the licensee to use this document. BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895 — 954-8314000 VALID OCTOBER 1, 2018 THROUGH SEPTEMBER 30, 2019 DBA: Receipt 183-294501 Business Name: LENNOX NATIONAL ACCOUNT SERVICES Business Type: HEATING/AIRCONDITION CONTRACTR LLC (AIR CONDITIONING CONTRACTOR) Owner Name: DILKS, JAMES LEROY III Business Opened:iO/19/2018 Business Location: 3511 NE 22 AVE 300 State/County/Cert/Reg:CAC1819182 FT LAUDERDALE Exemption Code: Business Phone:954-537-5544 Rooms seats Employees Machines Professionals 10 For Vending Business Only Number of Machines: Vendina Tvoe: Tax Amount Transfer Fee NSF Fee Penalty Prior Years Collection Cost Total Paid 27.00 0.00 0.00 0.00 0.00 0.00 27.00 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is non -regulatory in nature. You must meet all County and/or Municipality planning WHEN VALIDATED and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations. Mailing Address: LENNOX NATIONAL ACCOUNT SERVICES L: Receipt $02C-18-00000305 3511 NE 22 AVE 300 Paid 10/19/2018 27.00 FORT LAUDERDALE, FL 33308 2018 - 2019 I DESCRIPTIONS (Continued from Page 1) —� First Supplemental Name applies to Policy# GL0019589: Randy H Lewis Revocable Trust Certificate holder is additional insured as respects General Liability only if required by written contract, and subject to the terms, conditions and exclusions as specified in the policy. Waiver of subrogation applies in favor of certificate holder as respects General Liability and Workers Compensation If required by written contract, and subject to the terms, conditions and exclusions as specified in the policy. ewr_�rrw v�o. #5912769IM912767 ACCMIX CERTIFICATE OF LIABILITY INSURANCE �� 7/1/2019 FDATE(MWDD/YYYY) 11/27/2018 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER LOCKTON COMPANIESCONTACT 2100 ROSS AVENUE, SUITE 1400 DALLAS TX 75201 214-969-6700 N(PHC No, o Ext : ac No E-MAIL AFFORDING INSURER A: ACE American Insurance ComDany 22667 INSURED Lennox National Account Services LLC 1318682 3511 NE 22nd Avenue, Suite 100 Ft. Lauderdale FL 33308 INSURER B : Indemnity Insurance Co of North America 43575 INSURER C : XL S ecialt Insurance Com an 37885 National Union Fin; Ins Co Pitts. PA 19445 INSURER E ACE Fire Underwriters Insurance Company 20702 INSURER F: COVERAGES *LENIN06 CERTIFICATE NUMBER: 15750558 REVISION NUMBER: XXXXXXX THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER POLICY NUMBER POLICY EFF POLICY EXPLTR LIMITS A X COMMERCIAL GENERAL LIABILITY CLAIMS -MADE � OCCUR Contractual Liab N N 1 HDO G71096531 7/i/2018 7/1/2019 EACH OCCURRENCE 3,000,000 DAMAGE TO RENTED PREMISES (Ea occurrence) $ 1,000,000 X MED EXP An one person)Excluded PERSONAL & ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: �{ POLICY❑ JET LOC OTHER: GENERAL AGGREGATE $ 3,000,000 PRODUCTS -COMP/OP AGG $ lO OOO 000 $ A AUTOMOBILE LIABILITY X ANY AUTO AUTOS ONLY SCHEDULED ONLY NON-OWNED X TTSONLD N N ISA H25159664 7/1/2018 7/1/2019 COMBINED Snt,INGLE LIMIT As $ 2,000,000 BODILY INJURY (Per person) $ XXXXXXX BODILY INJURY (Per accident $ PROPERTY DAMAGE (Per accident) $ XXXXXXX $XXXXXXX C X UMBRELLA LIAB EXCESS LIAR X OCCUR CLAIMS -MADE N N US00085074LI18A 7/l/2018 7/1/2019 EACH OCCURRENCE $ 10,000,000 AGGREGATE $ 10,000,000 DED I I RETENTION $ $ XXXXXXX 13 A E WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETORIPARTNERIEXECUTIVE Y/N OFFICERIMEMBEREXCLUDED? N❑ (Mandatory in NH) If yes, describe under DESCRIPTION OF OPERATIONS below N/A N WLR C65224719 (AOS) WLRC65224756 (AZ,CA,MA) SCFC65224793(WI) 7/l/2018 7/1/2018 7/l/2018 7/1/2019 7/1/2019 7/1/2019 PER OTH. X STATUTE ER E.L. EACH ACCIDENT $ 1000000 E.L. DISEASE - EA EMPLOYEE 1,000,000 E.L. DISEASE - POLICY LIMIT Is 1,000,000 D Crime IN N 01-581-63-35 7/l/2018 7/1/2019 $15,000,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more specs is required) RE: James L Dilks CAC1819182. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 15750558 AUTHORIZED REPRESENTATIVE Village of Miami Shores Building Department 10050 NE 2nd Avenue Miami Shores FL 33138 ACORD 25 (2016103) 01988-2015 ACORD CORPORATION. All rights reserved The ACORD name and logo are registered marks of ACORD L���x O' NAS MANAGER Coe TD BANK/CBRE 10-0000 TDG0030 TO BANK D21 ` , PteDhan (5131 68 8286 Pu(000) 00Ssan MIIAMI! FL 33138- 2SCAYNE NATI60NAL ACCOUNTS F: (0001000-0000 susan.tvrell(aDcbre.com P: (305) 751-1499 steghan.coe(@Lennoxnas.com Mod Quote: 916490 PO #: TDU27084387 t SCID: 11804-27060 j Date: 15/7/2018 l We are pleased to quote you on the following equipment: Unit # Type Location Year Tons Manufacturer Model T Serial Rating Down l 61 CONDENSER MAIN FLOOR 2013 12.0 DAIKIN RXYQ144PBT1 A000540 8 0% Description of work: While on a service call technician found unit has failed inverter board and compressor. Received verbal approval to replace unit. Estimated time to completion after customer approval: 1 days Qty Item Amount Extended 1 20016 - INSTALLATION ONLY - CONDENSER UNIT, 11-1S TON, UNIT 01 $2,247.84 $2,247.84 1 DIAKIN 12-TON CONDENSER $20,033.39 $20,033.39 1 ADDITIONAL PERMIT FEES $1,274.00 $1,274.00 1 ENGINEERING $770.00 $770.00 Labor: $833.30 Material: $23,491.93 Total: $24,325.23 • •••••• • •••••• • All material is guaranteed to be as specified. All work to be completed in a professional manner according to standard practices. Any alteration or deviation from above specifications involving extra costs will be executed upon written orders, and will become an extra charge over and above the estimate. All agreements contingent upon strikes, accidents or delays beyond our control. Owner to carry fire, tornado and other necessary insurance. Our workers are fully covered by Workers Compensation Insurance. This proposal may be withdrawn if not accepted within 30 days. Authorized Signature: Acceptance of Proposal -The above prices, specifications and condifions are satisfactory and hereby accepted. You are authorized to do the work as specified. Payment will be made as outlined above. TEXAS - REGULATED BY THE TEXAS DEPARTMENT OF LICENSING & REGIS. P.O. BOX 12157, AUSTIN, TX 78711 1-800-803-9202 CACO 16307 CGC041603 EC0000961 GA402243 TACLA019292E Z PU Submittal Data Sheet 12 Ton, 230V VRV IV HP RXYQ144TATJU FEATURES • Larger capacity single modules ranging up to 14 tons and systems up to 34 tons allow for a more flexible system design • Variable Refrigerant Temperature (VRT) control allows the VRV IV to deliver up to 28% of improvement in seasonal cooling efficiency compared to previous Daikin VRV heat pump systems • Modular and lightweight enables flexibifity in system layout and installation with larger capacity single modules reducing electrical, piping connections • System wide auto -climate adjustment technology to increase the energy efficiency a Improved efficiency with IEER values now up to 28 • The rated seasonal cooling efficiency has been improved by an average of 11% • All inverter compressors to increase the efficiency and avoid starting current inrush • Same product structure for 230V and 460V simplifies ordering • New configuaator software designed to simplify the commissioning and maintenance of the system • Factory standard coil guards • Assembled in the US to increase flexibility and reduce lead times • Standard Limited Warranty: 10-year limited parts warranty BENEFITS + Can operate up to 25 indoor units on a single piping network + Modular and lightweight - enables flexibility in system layout and installation • Refrigerant cooled inverted technology to avoid influence from ambient temperatures • Integrated inverter technology deliver maximum efficiency during part bad conditions and provide precise individual zone control • Heat exchanger coil wraps around on all 4 sides of the unit to increase the surface area and efficiency a 3 row 7mm heat exchanger coil improves efficiency + Corrosion resistance 1000hr salt spray tested Dafldn PE blue fin heat exchanger • Design flexibility with long piping lengths up to 3,280 ft. total and 100 ft. vertical separation between indoor units • Designed with reduced MOP to optimize installation cost • Digital display on the unit for improved and faster configuration, commissioning, and trouble shooting AN .p�'Ne(rg antus Temperature • • • • •••••• •••••• • •• • •••• • •••••• •••••• •• • • • • • • • • ••••• •••••• •••••• Daikin North America LLC, 5151 San Feipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data wrnv.daikinac,com vmw.daikincomfort.com (Da kin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information In this data sheet without notice and without Incurring any obligations) Submittal Date: 9/1212018 9:04:27 AM Page 1 of 3 Submittal Data Sheet 12 Ton, 230V VRV IV HP RXYQ144TATJU �K Outdoor Unit Model No. RXYQ144TATJU Outdoor Unit Name: 12 Ton, 230V VRV IV HP Type: Heat Pump Unit Combination: Indoor (°F DB/WB): 80 / 67 Rated Goofing Conditions: Ambient (°F DB/WB): 95175 Rated Heating Conditions: Indoor (•F DB/WB): 70 / 60 Ambient ('F DB/WB): 40 / 43 Rated Piping Length(ft): Rated Height Difference (ft): Rated Cooling Capacity (Stu/Airy 138,000 Rated Heating Capacity (BbAr): 154,000 Nom Cooling Capacity (Btu/hr): 144,000 Nom Heating Capacity (Btwhry 162,000 Cooling Input Power (kW): 11.80 Heating Input Power (kW): 11.10 EER (Non-Ducted/Ducted): 12.10 / 11.50 Heating COP (Non-Ducted/Ducted): 3.6 / 3.3 IEER (Non Ducted/Ducted): 24.80 / 22.60 Heating COP 17F (Non-Ducted/Ducted): 2.3 / 2.2 �•i" Win•>,,,��-�, Power Supply (V/Hz/Ph): 208-230 / 60 / 3 Compressor Stage: Inverter Power Supply Connections: L7, L2, L3 Ground Capacity Control Range (%): 11 -100 Min. Circuit Amps MCA (A): 55.1 Capacity Index Limit 72.0 - 187.0 Max Overcurrent Protection (MOP) (Ay 60 Airflow Rate (H) (CFM): 8228 Max Starting Current MSC(A): Gas Pipe Connection (inch): 1-1/8 • • "' + • • • • • •••••• Rated Load Amps R Liquid Pipe Connection (inch): 1/2• • • • • o • • • • • •' • •••••• Dimensions (Height) (in): 66-11/16 H/L Pressure Connection (inch) • + ego* • • • • • • • • Dimensions (Width) (in): 48-7/8 H/L Equardng Connection (inch) • • • �' + • • • • • • • • • • Dimensions (Depth) (in): 30 3/16 Sound Pressure (H) (dBA): •• •• 64• • • • • • •• • • • • •: • Net Weight (lb): 695 Sound Power Level (dBA): • 8E6 • • :**ego 994110 oo Max. No. of Indoor Units: 25 • • • • • Daikin North America LLC, 5161 San Felipe, Suite 500, Houston, TX, 77056 Daikin City Generated Submittal Data www.daikinac.com iwiw.daikincomfort.com (Dakin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date: 9/12/2018 9:04:27 AM Page 2 of 3 Submittal Data Sheet 12 Ton, 230V VRV IV HP RXY0144TATJU Refrigerant Type: R-410A Cooling Operation Range ('F DB): 23 - 122 Holding Refrigerant Charge pbs): 18.1 Heating Operation Range ('F WB): -4 - 60 Additional Charge (Ib/ft): Max Pipe Length (Vertical) (ft): 295 Pre -charge Piping (Length) (ft): Cooling Range w/BafBe ('F DB): - Max Pipe Length (Total) (ft): 540 Heating Range wBaffle ('F WIB): Max Height Separation (Ind to Ind ft): DIMENSIONAL DRAWING Daikin North America LLC, 5161 San Felipe, Suite 500, Houston, TX, 77056 e� • ad* • • •ra sees% • ••a••• • • • • • •••ar ••••• • • ••l••• • f 0 • • • • r • • • • a • •• • •• • •a•a• • so 0 Daikin City Generated Submittal Data www.daikinac.com aAAv.daikincomfort.com (Dakin's products are subject to continuous improvements. Daildn reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Date: 9/12/2018 9:04:27 AM Page 3 of 3 NOTE: ALL DETAILS HAVE BEEN DESIGNED TO MEET ALL ANTICIPATED LOADING CONDITIONS OUTLINED IN THE 201-7 FLORIDA BUILDING CODE (Toth EDITION) FOR A 115MPH, RISK CATEGORY II, EXPOSURE "C" WIND LOAD EVENT. AddrftS. 9005 Biscayne Blvd Miami, Fkwida $3136 Wind ASCE 7 Hazards Report Standard: ASCE/SE17-10 Risk. Category: II Soil Class: D -Stiff Soil El"ation: 7,97 tt (NAVo 88) Latitude: 25-W108 i.0"gitUde:-60.18394 \\\\IIIIIIIII////'/ � M.8 p . �GENS No.55428 STA 0 F s �ON'A\- �\``�`\� s • • • sees•• • sees•• sees • • see• sees•• • • s • sees•• • Is • • • • ttsu6t - Wnd Speed' i 69 �Imrpit 10-y*arMRI go Vmph 25-}near MRI 112 vrtrph 50-year MR1 127 Vnpb 100-year MRI 130 Vrnph Data sourcr3' ASMSE17-10. Flg. 26.5-1A and nlgs. CCA-CCA, Incmpot-A" errata of March 12, 2014 Date >+ ssw: Tnu E*0 06 2018 Value provided is 3-secoM gust,iAnd sods at 33 ft above ground for E C C.awyory, boSed on lir*ar interpokitilon betvmw contours_ Wind qxoo& ate interpdated in ao0ordamce Witt1 ttw� 7-10 Standard. Wind speeds correspond to VpvoAmately a 7% probablllry of oxcoodanc;o In 60 years (Ammual eliseodanc a probability = O. 01d3. MRI = 700 years). Site is in a hurricane -prone region as defined in ASCE/SEI 7-10 Section 26.2. Glazed openings shall be prdteded against wind-borne debris as specified in Section 2&10.3. -RBE CONSULTING SERVICES, LLC H47, �FW,<07. xA:.i875 • F:X, AF70 SWIM, IM, DEPT, 4Z 796.MM • eve 7iE@RCrs cow iR 'a 001•L•• •T�®, LLC MAY dll1LT 109110 M •� M• K ®01 m?Am tM M ®1 MO M11 NY K�OIA\K se wf6119®IM s• m®rt • a may em uc. • • s • • • •• sees•• • • • sees•• sees•• • sees• • •• • sees• • • • • • • sees•• sees•• • • • • • • • • • • PROJECT NO. 18-LENNOX-080 PROJECT: DRAWN R8 TD Bank TD00010 RMa 9005 Biscayne Blvd. APPROVED Miami, FL 33138 DATE 12-6-18 DRAWING NO. NEW RTU TO EXISTING ROOF RACK SK-1 OF 2 " _ s� ' ' it Al zte r , ask g ? igffi o 2 `� TRANSVERSE DIRECTION ATTACHMENT REQUIREMENTS RTU TO EXISTING ROOF RACK OPTION 01: PASTEN RTU TO ROOF RACK W/ 11) J"O GALVANIZED A325 BOLT W/ WASHERS AND MATCHING NUT EACH CORNER OPT UNIT AND AT A MAXIMUM SPACING OP .� RGS iro LONGITUDINAL DIRECTION ATTACHMENT REQUIREMENTS RTU TO EXISTING ROOF RACK OPTION $I: PASTEN RTU TO ROQP RACK W/ (1) i-m GALVANIZED A325 BOLT W/ WASHERS AND MATCHING NUT EACH CORNER OP UNIT AND At A MAXIMUM SPACING OF m > t A En i m c- 48-o.c. (MIN. OP 4 BOLTS PER UNIT) 48"o.c. (MIN. OP 4 BOLTS PER UNIT) 0 o RTU TO EXISTING ROM RACK OPTION 02: RTU TO EXISTING ROOP RACK OPTION 02: 0 n PASTEN RTU TO ROOP RACK W/ 2" WIDE x PASTEN RTU TO ROOP RACK W/ 2- WIDE x N m 12ge CLIP ANGLE/PLAT STRAP FASTENED 12ga CLIP ANGLE/PL,AT STRAP PASMOD N a, m I Fn TO RTU W/ MP) 014 TEKS AND TO ROOP TO RTU W/ (5) 014 TEKS AND TO ROOP co z RACK W/ (1) J"O GALVANIZED A325 BOLT RACK W/ (I) i"m GALVANIZED A325 BOLT X W/ WASHERS AND MATCHING NUT. (5) 014 W/ WASHERS AND MATCHING NUT. (5) 014 o o TEKS CAN BE SUBSTITUTED FOR THE J-0 EXISTING ROOF IRKS CAN BE SUBSTITUTED FOR THE J"0 BOLT SPECIPIED. RACK-TYP. BOLT SPECIPIED. RTU TO EXISTING ROOP RACK OPTION 03: RTU TO EXISTING ROOP RACK OPTION 03: Z K: o 0 0 PASTEN RTU TO ROOP RACK W/ J"x20 PASTEN RTU TO ROOP RACK W/ J"x2" Q 0 L LONG PILLET WELD EACH SIDE OP 2" WIDE LLE LONG PILT WELD EACH SIDE OP 20 WIDE cn pp m x 12ga BASE CLIP BY RTU x 12ga BASE CLIP BY RTU MANUPACTURER. WELDS SHALL. BE MANUPACTURER. WELDS SHALL BE c m TOUCHED -UP W/ ZINC RICH PAINT T EXISTING ROOPING TOUCHED -UP W/ ZINC RICH PAINT TO ►- PREVENT CORROSION. NEW CONDENSER UNIT PREVENT CORROSION. O 0 w (��D O O ON EXISTING ROOF RACK X w �� cn 00 - O a Z 0 _ O LOCATION OP TRANSVERSE DIRECTION • • " ' �i ATTACHMENT REQUIREMENTS • �' • ��. 'cn o: D n LOCATION OF LONGITUDINAL '.' ... ... ... ... '.' = n 7° m * z - r N Q7 .' DIRECTION PLAN VIEW OP ii'T'U : • •. • LOgATIQN OP / �2 ''. -n ATTACHMENT LONGITUDINAL •C ` :�i REQUIREMENTS DIRECTION 1;7- ... LOCATION CP TRANSVERSE DIRECTION •• �' ': •' •:• :' ': ATTACHMENT REQUIRIN IMPS RBE Consulting Services, LLC PH: 407-796-3820 2875 Split Oak Court -Oviedo, FL 32766 FX: 407-796-3671 Email: rbecsllc@gmail.com Website: www.rbecs.com Design of Connection of New RTU on Existing Roof Rack Unit Conversions: psf:=lb — kip := 1000 • Ib ksi :_ kip — ftZ W Wind Load Determination: Based on ASCE 7-10 - Risk Category H V:= 175 mph Basic Wind Speed Exposure Category: C oar mu woDMo GwmiM.lmco�l®n� /jo•XW"&WMQYd*mob •cOmw woOiwIIa•0hivwiOb.ftw6wa IRMI: L O1Ma�� Rrp3waaL��1 �RSf � MbR � OiMDa7aRI1Ca0 MR Its � � [mpeeDtlalt:AM1�4111��IM� � i1�0� WI RMY �oM rMMO� A art oRduw /+� wr � ]Mt �0 R� �40oM �14 AM�wo� &Nwwhsai►pp%w=pmmwu1wwdgwM•ilnj=id iw=mwhWIw==didW �-aaa�u.� • 7Cotl.no. • ••••�• =90ftWNRIda: .•• .. ...... vhb rMr �.. . . . JVMMNZSVOVJ ...... .. . ..... .. .. .. . ...... • • • • •••••• Risk Category U • • • A := 67 • in Height of Unit C := 49 • in Length of Unit MU:= 695 • lb Unit Weight B := 0 • in Hght of Curb/Rack (if applicable) D := 30 - in Depth of Unit CW:= 0 • lb Curb Weight r--------------� fr_-----� I I I I I I I 1 I ROT MP V:J410 I I R13OF r-32 VCLPAM I �y^ I Y&MMAL UNIT I 'e" I N104ANCAL t;'Ni I I !U l CCAI.6CTMS El ( } CMCC1101S SEE I I CALCIiAIMMS I I — CALCULATMS I I I I I I RMF W A/C I — _ I ROOF TEF AIC ------------ COWS (NN. -ST) ` — CiUZR [WW fbg•) _ I T_ RCCFNC F 1—ROEMT1IG (SICK VIEW} (Et�C3 +lE�yJ P-00P TOP MOUNTED UNIr ,RBE Consulting Services, LLC PH: 407-796-3820 Email: rbecsllc@gmaii.com 2875 Split Oak Court -Oviedo, FL 32766 FX: 407-796-3671 Website: www.rbecs.com Kzt:=1.0 EQ. 26.8-1 Kz := 0.85 Table 29.3-1 Kd := 0.85 Table 26.6-1 r.eae 1�012 orgy aar l�il1�11"n MMMAf "" GB CMPN"mlcimft Haar At" nes Q �7a11d.�1�IrNat�w nw► s as slwei an i�i6�i4RelVedMd 6•�[ud+lrr�iei�+ OAS 0� -d Gas Ts� Tr•s 70= - nae4r aes Al a eta on i a I MrVa•� er�l•ilwelRan dJ .pr�ea rso4e6•p)uewaarea w cm*ww&)"vK*bvd=wvdbdaalrII UwAIA Bhoriz := 200 • ft Lhoriz := 200 • ft h:=15•ft Af1:= (A) • C Aft := (A) • D Aft = 23 ft' Afl =14 ft' q, := (0.00256 • Kz • Kzt • Kd - V2) •psf qh = 57 psf SW:=MU+CW SW=0.695 kip Self Weight of RTU & Curb OM = Overturning Moment RM = Resisting Moment '��.vooao �trim 11111111111111113. 111111 o.NUDIII.o� E_ �_ tT� �� CFI• NKFJM � �l l! _tT�_ i�� �F:"1• �� MIL_ _i?!�_ 0w -:. IIIIIK3F7 0 tc.-.i_ ©� IIIINE11rIIIIIIII 0 �7 WMEM 111111111�'�® lwdw: 1. Dr GYP aspowumawfilwesXiMay bedo"MoleedI=thehaffi g PwJ5A.fa9rt PIxa�l3t�k• • • ;••••• 1 a eadrs es tabdatei la Tebb 2a AL • • • ILboarkintpoirtloa3:rhisomalids Velma at1 jwo o. 0• • 4. &pome a Wpodm a dahmd In ft im 15.1f • • • • • •••• • • • • • •••• •••••• • •• •• • • •• • •••••• • Horizontal Dimension of Building Normal to �ndDirection Horizontal Dimension of Building Parallel to Wind Direction Mean Roof Height Area of Unit Along Length of Unit Area of Unit Along Width of Unit Velocity Pressure ro M -------i r--------i �I SW "A'f2 + i i RM ,R¢E Consulting Services, LLC PH: 407-796-3820 Email: rbecsllc@gmail.com 2875 Split Oak Court -Oviedo, FL 32766 FX: 407-796-3671 Website: www.rbecs.com Transverse Horizontal WL GC,h, := 3.1 GC,h, = 3.1 Fh, := qh • GC,*, • Afl Fh, = 4.003 kip Transverse Vertical WL GC,,,, :=1.5 GCrv, =1.5 Fv, := 9h • GCr,,, • Afl Fv1=1.93 7 kip Lonaitudinal Horizontal WL GC,h2 := 3.1 GC,h2 = 3.1 Fh2 := 9h • GCr12 - Af2 Fh2 = 2.451 kip Longitudinal Vertical WL GC,v2 :=1.5 GC,,,2 =1.5 Fv2 := 9h - GC,,,2 • Af2 Fv2 = 1.186 kip Transverse Loading Design Longitudinal Loading Design OMT:=0.6Fh,•(2) OMT=6.706ft•kip OML:=0.6Fh2•(2) OML=4.105ft•kip DOMT:=1.5.OMT Design Overturning DOML := 1.5.OML JJ Design Overturning DOMT= 10.05(D) 8 ft -kip Moment - Transverse DOML = 6.158(ft •)kip Moment - Longitudinal ORMT:=SW• Overturning Resisting ORML:=SW• (T) Overturning Resisting 2 Moment - Transverse Moment - Longitudinal ORMT= 0.869 ft • kip ORML = 1.419 ft • kip CompareT="Fastening is Req. to Resist Applied WL Conditions in the Transverse Direction" Compare,, = "Fastening is Req. to Resist Applied WL Conditions in the Longitudinal Direction" DOMT — ORMT F,,, DOML — ORMr, Fv2 DSRT:= +— Req. Fastener DSRL= +— Req. Fpsterler D 2 Resistance Capacity - C 2•Resist4Md2 Capaci" ; � • DSRT=4.644 kip Transverse DSRL=1.754 kip '..' Longitudinal. ...... .. ...... TC := 2640 • lb TC = 2.64 kip Tension Capacity of Each 3/8"dia. Bolt. • • • •. • DSRT Req. # of Bolts Per Side to Resist DSRL Req.#-of•Conc. Bolts -Per SA410•: NSRTT:= Applied WL - Transverse NSRTL := Resist lied 1I�L - ton itudinal• • TC pp TC � g ...... .. . ..... NSRT 1.759 NSRT = 0.664 • 000000 NSSRTT:=NSRTT+0.5 Net Req. # of Bolts Per Side to NSSRTL:= NSRTL + 0. 5 Net Fd�ec #of Bolts per Side to •• NSSRTT= 2 Resist Applied WL - Transverse NSSRTL = 1 Resist Applied WL; Lai gitudinal-: - Condenser to Existing Roof P6&k::-:- (Direct Bolted Unit to Roof Rack) Attachment Along Length of Condenser: (Transverse Direction) Use NSSRTT.= 2 3l8"dia. Bolts w/ Washers and matching Nuts Attachment Along Width of Condenser: (Longitudinal Direction) Use NSSRTL= 1 3/8"dia. Bolts w/ Washers and matching Nuts AW:= 2 • in Clip Angle Width AT:= 0. 10 17 • inClip Angle Thickness AS:= 33 • ksi Clip Angle Material Strength NCAPST:=2 # of Clip Angles Per Side (Transverse) NCAPSL:=2 # of Clip Angles Per Side (Longitudinal) AC:= (AS) • (AW) • (AT) • (0.45) AC= (3.02.10') lb Angle Capacity WL := 2 • in Length of Weld WT := 0.11 • in Thickness of Weld WS := 60 • ksi Strength of Weld Material NWST:=2 # of Weld Sides Per Clip (Transverse) NWSL:=2 # of Weld Sides Per Clip (Longitudinal) WCT:= (0.3) • (NWST) • (WT) • (WL) • (WS) Weld Capacity WCL := (0.3) • (NWSL) • (WT) • (WL) • (WS) Weld Capacity WCT= (7.92. 10') lb (Transverse) WCL = (7.92.10') lb (Longitudinal) SC := 500 • lb SC = 0.5 kip Shear Capacity of Each #14 Tek Screw ,RQE-Consulting Services, LLC PH: 407-796-3820 Email: rbecsllc@gmail.com 2875 Split Oak Court -Oviedo, FL 32766 FX: 407-796-3671 Website: www.rbecs.com Weld Check: DSRT NCAPSTWCT WeldCheckT := if > 1.0 , `No Good in Transverse Direction", "OK in Transverse Direction " WeldCheckT="OK in Transverse Direction " DSRL NCAPSLWCL WeldCheckL := if > 1.0 , "No Good in Longitudinal Direction", "OK in Longitudinal Direction " WeldCheckL = "OK in Longitudinal Direction " C1012 Capacity: DSRT NCAPSTAC ClipCheckT:= if > 1.0 , "No Good in Transverse Direction", "OK in Transverse Direction " ClipCheckT= "OK in Transverse Direction " DSRL NCAPSLAC ClipCheckL := if > 1.0 , `No Good in Longitudinal Direction", "OK in Longitudinal Direction " ClipCheckL = "OK in Longitudinal Direction " Screw Reauirement: • • .. . .. . • DSRT (NCAPST)-NCAPSL.oMso:RNSST:=Req. DSRL •••••• . . • •• •••••• # of Screws RNSSL :_ • • • • Re . # of Screws • SC Per Strap- SC •••••• VerSt�ap- ••o••• RNSST=4.644 Transverse RNSSL= 1.754 ••:•• �6mgitVdinal••••• NRNSST:= max (RNSST+ 0.5 , 2.0) Net # of Screws NRNSSL := max (RNSSL + 0.3' 2 NLt 9of Scrdit* ;' NRNSS 5 T Per Strap - NRNSSL 2 • • Perttrap - •. Transverse ioiaghdinal• • 6 • • • ...... .. & , (Screw Fastened to Clip &Bolted to Roof Rack) Attachment Along Length of Condenser: (Transverse Direction) Clip Angle shall be attached to RTU with NRNSST= 5 #14 tek screws and to Roof Rack w/ (1) 3/8"dia. Bolt w/ Washers and matching Nuts. Attachment Along Length of Condenser: (Longitudinal Direction) Clip Angle shall be attached to RTU with (4) #14 tek screws and to Roof Rack w/ (1) 3/8"dia. Bolt wl Washers and matching Nuts. Condenser to Existing Roof Rack: Oation #3 (Welded to Clip & to Roof Rack) Attachment Along Length of Condenser: (Transverse Direction, 1/8"x2" long Fillet Weld each side of base clip by RTU manufacturer. Attachment Alona Lenath of Condenser: (Lonaitudinal Direction) 1/8"x2" long Fillet Weld each side of base clip by RTU manufacturer. Is �® Rgli__W d'm'mm Certificate ®f Product Ratings AHRI Certified Reference Number: 7041887 Date : 12-18-2018 Model Status : Discontinued Brand Name: DAIKIN Series Name: VRV IV AHRI Type: HMSV-A-CB Indoor Type: Non -Ducted Indoor Units System Model Number : RXYQ144TTJU Module Model Number 1 : RXYQ144TTJU Rated as follows in accordance with the latest edition of AHRI Standard 1230 for VRF Air -Conditioning and Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (95F) : 138000 EER (95F) : 12.30 : • • • • • • • • IEER:24.10 •••••• i �••� •••• • High Heating Capacity (47F) : 154000 "••• High COP (47F) : 4.10 "" ' "" • Low Heating Capacity (17F) : 96000 • • • • • ° • • • • • • • • • • Low COP (17F):2.33 :��:•: • • tModels with "Discontinued" Model Status are those that an AHRI Certification Program Participant no longer produces AND is no longer selling or offering for sale. Ratinas that are accompanied by WAS indicate an involuntary re -rate. The new Dublished rating is shown along with the previous (i.e. WAS) rating. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and am confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, In any form or manner or by any means, except for the user's individual, personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link we make life better' and enter the AHRI Certified Reference Number and the date on which the certificate was issued, _ which is listed above, and the Certificate No., which Is listed at bottom right. ©2018Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 131896205908536954