Loading...
FW-18-3751Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Issue Date: 01/04/2019 Location Address Parcel Number 72 NW 97TH ST, Miami Shores, FL 33150 1131010330350 Contacts Permit NO.. FW-12-18-3751 Permit Type: Fence/Wall Work Classification: Wood Fence Permit Status: Approved Expiration: 06/ 19/2019 GLORIA & REGINALD MASHACK TRS Owner 72 NW 97 ST, MIAMI SHORES, FL 33150 HENRY'S FENCE INC Contractor HENRY VILLOCH 3931 SW 63 AVE, MIAMI, FL 33155 Business: 3056690180 Description: WOOD FENCE 6' HIGH HORIZONTAL, INCLUDING Valuation: $ 2,400.00 Inspection Requests: 2 GATES 305462-4949 TotalSq Feet: 0.00 Fees Amount Application Fee - Other $50.00 CCF $1.80 DBPR Fee $2.00 DCA Fee $2.00 Education Surcharge $0.60 Planning and Zoning Review Fee $35.00 Scanning Fee $9.00 Technology Fee $2.50 Wire and Wood Fence Fee $50.00 Total: $152.90 Payments Date Paid Amt Paid Total Fees $152.90 Check # 1569 01/04/2019 $102.90 Check # 1535 12/21/2018 $50.00 Amount Due: $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize `the above named contractor to do the work stated. Authorized Signature: Owner / Applicant / Contractor / Agent Date January 04, 2019 Page 2 of 2 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING 7PER IT APPLICATION UILDING ❑ ELECTRIC ❑ ROOFING M19 tw F C20_3 Master Permit No. Sub Permit No. ❑ REVISION ❑ EXTENSION ❑ RENEWAL ❑ PLUMBING ❑ MECHANICAL [:]PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: %Z N W o 1 / City: Miami Shores _ Count): Miami Dade Zip: 5-0 Folio/Parcel#: k\— 3I O\ — O'J;bIs the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type : Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): G CoiiJe� • AA��1Q Phone#: � % S%/3 City: " '7 7�—' 1 State: Tenant/Lessee Name: Email: Im ne#: p: CONTRACTOR: Company Name:Phone#: 'JCYmS `0lD5 Address:`���� City: 4 V`%; State: 'V' Zip: Qualifier Name: ✓1`r"'� �. 'AA %Q Phone#:'2:� t Qua►— c.)X% State Certification or Registration #: Certificate of Competency #:iaq DESIGNER: Architect/I ngineer: Phone#: Address:, City: "` ' ' .r State: Zip: Value or "Work for this Pbrrnk$ " al jrP Square/LinQar footage of Work: •_'' �0 _ Type of Work: ❑ Addition, f ❑ Alteration ❑ New ` Repair/Replace; , ❑'Demolition Description of Work:, Y ,] t, t CIA 'V% C Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ .Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ v (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which o seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection wilInq/be �proved nd rein&ec a will be charged. ��rffi AN, ANOVEM, OWNER or The foreg ing ins`t !yent was acknowledged before me this ay of 20 by who is p nally kno 0 me or who has produced as 1 identification and who did t`�oOD/�jG��,��i/// NOTARY PUBLIC: ,•,�Zt�,,,�n,0ie'•` 2 CONTRACTOR The foregoing instrument was acknowledged before me this J-*ay of 20 by is personally know me or who has produced .��\\ �.._�////i,_ as identification and who did take KM,ARY PUBLIC: Sign:_ Print: Seal: IFF OMW y STO- mi{i1110 ,/ APPROVED BY Z t C Plans Examiner 12 �" Zoning Structural Review Clerk (Revised02/24/2014) Henry's Fence Inc. Miami Shores Village 10050 NE 2nd Ave Miami Shores, FL 33138 Job Address: 72 NW 97d' Street Miami Shores, FL 33150 December 12, 2018 I, Henry P. Villoch, president of Henry's Fence Inc, will be the only person installing and working on this fence project. Should you need any further information, feel free to contact me. Sincerely, uevery P. vaica;v RIGU��ii���� EXPj� �i 20 S' • •• * i S •� ISos m.0� �L0 -- aY P ti Gv�`a0�Z� Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Notice to Owner - Workers' Compensation Insurance Exemption Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat. § 440.05 allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to obtaining a building permit. Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure: An employer in the construction industry who employs one or more part-time or full-time employees, including the owner, must obtain workers' compensation coverage. Corporate officers or members of a limited liability company (LLC) in the construction industry may elect to' be ' exempt if: 1. The officer owns at least 10 percent of the stock of the corporation, or in the case of an LLC, a statement attesting to the minimum 10 percent ownership; 2. The officer is listed as an officer of the corporation in the records of the Florida Department of State, Division of Corporations; and 3. The corporation is registered and listed as active with the Florida Department of State, Division of Corporations. No more than three corporate officers per corporation or limited liability company members are allowed to be exempt. Construction exemptions are valid for a period of two years or until a voluntary revocation is filed or the exemption is revoked by the Division. Your contractor is requesting a permit under this workers' compensation exemption and has acknowledge that he or she will not use day labor, part-time employees or subcontractors for your project. The contractor has provided an affidavit stating that he or she will be the only person allowed to work on your project. In these circumstances, Miami Shores Village does not require verification of workers' compensation insurance coverage from the contractor's company for day labor, part-time, employees or subcontractors. BY SIGNING BELOW YOU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS CONTENT 1)W6 17 -Signature: ((� wne _. State of Florida County of Miami -Dade The foregoing was acknowledge before me this _g y of , 2012� . .. ��� U�'�1 q'��``C� ������ KOS RopR By whc`�b r �Ao:@k4Jj&4;bpae or has produced as me Not SEAL: N� $lion. #FF9W27 c o��- Miami Shores Village Building Department SURVEY AFFIDAVIT STATE OF (FLORIDA) COUNTY OF (DADE) 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 The undersigned Affiant, C- % bpi a, hereby attest that (Property owner) The attached survey, performed by� p t--� 4 -D���e�`� C (Name of surveyor's company) For address: ""1•? L-3-'� g`-N -1:5\-4r r-- , Performed on n1 (date of survey) is an accurate representation of the existing conditions and locations of all str ctures on the property as of this date. The purpose of this Affidavit is to induce Miami Shores Village to issue a building permit for the property without first providing a survey less than seven (7) years old old. The Affiant, as property owner, further agrees to remove or obtain permits for any structures which now may exist on the property which are not permitted or which may violate zoning or building code regulations. The Affiant further understands that the existence of any such ruc res ma ffect nal ' ections as applicable to this or other permits. er; Affi sae g t. Lt— rProp6irtTOw—ner Signature Property" Owner - not Name SWORN TO AND SUBSCRIBED before me this i�A� �B ) Affiant is personally known to me, identification. EGG gr%120y i Z N Z ' y #FF 8US27 *� Revised on 5122/2009/ Revised on 6/12/09 ��y,� eO�ded thN ,g' 40 y "rlbllc under orfct: 4201 L1t AWNt MO. LAW fYRYRYM TILtrM1011ts CORAL OASLa. ". 33146 AMM, FLOWA MNYRY M M BR• 77- 2 3 0 VEY 0r. LOT i E- d(gU7- YV o;E 1n f- 9 a�r� l . &41 /o 1' /0 BLOCK +"�U SUBDIVISION ACCORDING TO THE PLAT THRREOF AS RECORDED IN PLAT BOOK NO. /o AT PAGE NO.,w Jo PUBLIC RECORDS OF QOWMj FLORIDA. DATE: ,c-,FZ / ?� /17 7 .-.. FOR:. 'PAW LOCATION SKETCH SCALE I"- 2otio ' I�her'eby certify that this sketch of 97'_ jFT survey of the above described property — is true and correct to the best of my knowledge and belief as recently surveyed and•platted under my direction. I further certify that this survey sleets the minimum requiremente,adopted by the, Florida Society of Professional Land Surveyors and the Ploridd Land Title Association. �,vae8� w.vp •9�yv. There are encref►c#iajentsGY • 44s + '. d 1 197.; 00 r ••• •AC • • Regi t'ered Engin F.; d8 N'••• shred Land y ;_i� .....� • State of Florida .. ..' :' '•' ..•••• ,-4.~.�/..uiw. .. . .. • ,•: N� •5•��a v EC 2 2 18 IV- 16-• ♦ 1444C"•. y �7eu�r re� � .c v�r. �%�rs LOT WTAIU FR < u' LL c�, Q GJ i 5 LU . JJ C3 J ri .0 L 0 . — ' Iol 4'-0" Maximum + + + +1 + _ +i + I a + + + Al - I.+�i� BD I + + v c + GL , + + U IF + t ..�. `%�\ �� �\ ��� `�\, i I:\�i,\r, .i\� �i `i ��,°R�� j\////\\' ��i�i �ii� %\\ \�!ii / : : V„yw Wood Fencing Elevation Scale:6LJ`1/2" =1'-0" uaie ueians Scale: 1/2" =1'-0" (Typical) -- Adjustable Self -Closing Hinge with Self -tapping #10 x 3/4" Hex Head Screws HI _ N a Hinge Detail — Automatic Latch with Self -tapping #10 x 3/4" Hex Head Screws o a� iB LA Latch Detail — N0TE. All Hardware is Galvanized or Stainless Steel 1/2"0 Center Drop Rod & Guide DR I with Self -tapping #10 x 3/4" Hex Head Screws Drop Rod Detail — n ' \mow 02 # Hardware Details (Typical -Single or Double) Scale: 1" 1'-0" (Typical) ID I DESCRIPTION I SIZE IREMARKS BD Board 1x6 Pressure Treated CN Common Nail 7dx1-1/2" Min. 2 nails per board @ each post connection, S.S. or Galv. DR Drop Rod 318"0 x 14" Minimum, Required on inactive leaf, Optional on active leaf GF Gate Frame 48" maximum Aluminum 2" x 2" perimeter frame with 2" x 2" vertical (center) GL Grade Line GP Gate Post 4" x 4" Minimum - Pressure treated Heavy Duty Hinge 10" Strap Style - Self Closing if used around a pool area —(:ID ® Latch 2" x 4" Self Latching (@54" aff min.) if used around a pool area LP Line Post 4" x 4" Minimum - Pressure treated PF Post Footing 10"0 x 24" 1 2,500 psi Concrete (Minimum) General Notes (Design): SECTION 2328 HIGH -VELOCITY HURRICANE ZONE— WOOD FENCES 2328.2 Fences not exceeding 6 feet (1829 mm) in height, shall be constructed to meet the following minimum requirements: from nominal 4-inch by 4-inch by 8-feet-long (102 mm by 102 mm by 2438 mm) posts No. 2 grade or better spaced 4-feet (1219 mm) on center, and embedded 2 feet (610 mm) into a concrete footing 10 inches (254 mm) in diameter and 2-feet (610 mm) deep. 2328.3 Fences not exceeding 5 feet (1524 mm) or 4 feet (1219 mm) in height shall be constructed as provided ui Section 2328.2, except that the spacing of posts may be increased to 5-feet (1524 mm) and 6-feet (1829 mm) on center for these heights, respectively. 0 1. Design complies with the requirements of the FBC2014 & AS£E 7!1"0, win8 speed 115 MPH 3 Second Gust, Exposure C. •• 0 V. 1 2. Gate leaf (single or double) widths can be installed up to the ;IU able size as shown in Detail 3 / W2.0. Should a double leaf gate be instillgc" then the: Latch and Drop Bolt shall be installed (per the local requiremegt�J.. • •„ 3. Wood shall be decay resistant and termite resistant (Pressure JrVAPd) ancL shall be grade #2 or better. 000000 •' •' 4. Fasteners shall be corrosion resistant. ...... 5. Finished side shall face out or shall be double sided (does not affbctthe engineering design). :"• 6. POOL AREAS: All horizontal rails shall be less than a minimu"spacing . F width of 1-3/4" apart. Horizontal spacing (between boards) has been designed for 1/4" to 1/2" typical but shall be less than 1-3/4" apart. 7. No changes are allowed without written authorization from the Architect. General Notes (installation): 1. SOIL @ GRADE POST CONNECTION: Anchored in 10" x 24" (2,500 psi) concrete. 2. BOARD / POST CONNECTION: (2) 16d (galvanized common) @ each post. 3. BOARD / GATE FRAME CONNECTION: (2) Self -Tapping SMS #12 @ each connection point (24" o.c. maximum). General Notes (Material): 1. SUPPORTING STRUCTURE: 1.1. Wood - Line Posts shall be 4"x4" (Minimum) with concrete footing (10"0 x 24") 1.2. Wood - Gate Posts shall be 4"x4" (Minimum) with concrete footing (10"0 x 30") 2. HINGE ATTACHMENT: 2.1. Concrete: 1/2"0 x 6" wedge anchors 2.2. Wood: 1/4"0 x 3-1/2" Lag Screws 2.3. Steel: Welded or 1/4"0 Carriage bolts with washer and nut. component -_-)cneauie & uenerai mies Scale: Not to Scale �o'� m po�a 2 U oQ o o- - Q w u N Z aft P L CL U � � ' E LL o B S • o co co ; � a c 'o c ta) N 8 o o �' � C> U5. a Ca U) r O -�-� O 2 � N ' U Sp O CD 9 ILL. W2.0