Loading...
BPP-17-2666Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Permit ►vO. BPP-11-17-2666 Permit Type: PootsMhirlpools/Hot Tubs Per im Work Classification: New Permit Status: APPROVED Issue Date: 1/26/2018 1 Expiration: 07/25/2018 Project Address Parcel Number Applicant 161 NE 106 Street 1121360060380 Miami Shores, FL 33138-2036 Block: Lot: JEAN ROY Owner Information Address Phone Cell JEAN ROY 161 NE 106 Street (786)483-7782 MIAMI SHORES FL 33138- 161 NE 106 Street MIAMI SHORES FL 33138- Contractor(s) Phone Cell Phone ESSIG POOLS INC 305-949-0000 Approved: In Review Comments: Date Approved:: In Review Date Denied: Type of Work: Swimming Pool Additional Info: NEW POOL & DECK Classification: Residential Fees Due Amount Bond Type - Contractors Bond $500.00 CCF $19.20 DBPR Fee $14.40 DCA Fee $9.60 Education Surcharge $6.40 Permit Fee $960.00 Plan Review Fee (Engineer) $80.00 Scanning Fee $9.00 Technology Fee $25.60 Total: $1,624.20 Occupancy: Private Bond Return Scanning: 3 Valuation: $ 32,000.00 Total Sq Feet: 817 Pav Date Pav Tvoe Amt Paid Amt Due k Invoice # BPP-11-17-65604 01/26/2018 Check #: 301941 $ 1,424.20 $ 200.00 11/08/2017 Check #: 301866 $ 200.00 $ 0.00 Bond #: 3620 Available Insnections: Inspection Type: Fence Final Pool Deck Wall Steel Review Electrical Review Building Review Structural Review Planning Review Plumbing In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICALAINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT-.;Ihat the regoi information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoningore, at rize th above -name contra or to do the work stated. z & Ile January 26, 2018 Authorized ign urts: Owner N Applicant / Contract& / Agent Date Building Odpartm nt Copy January 26, 2018 1 BUILDING PERMIT APPLICATION Miami Shores Village ; =�CR vT_ Building Department Nov 0 2017 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 2014 Master Permit No. )0P 1-7— Z-Cjhb Sub Permit No. OBUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGEOF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 11- 2 )3 (,- OdC. - D W-0 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): '� _ l� ��� Phone#: �3 - n aZ Address:_ 10(o 5,T City: _ i�r,. •�. �j �o �c ( State: i Zip: Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: Essig Pools, Inc 1800 NE 151 S Address: t 305-949-0000 City: North Miami State: FI Zip: 33162 Qualifier Name: Daniel Essig Phone#: State Certification or Registration #: CPC052505 Certificate of Competency #: DESIGNER: Architect/Engineer:Phone#: Z'!3l— Address: t!f (e L. City: AA i --x I State: Zip: 3319- Value of Work for this Permit: $ 1,04000 Square/Linear Footage of Work: 16 1 } Type of Work: ❑ Addition ❑ Alteration t� " ®" New ❑ Repair/Replace ❑ Demolition Description of Work: gv0\ c.'X � ,t If_ Specify color of color thru tile: Submittal Fee $ �T�3A Permit Fee $ �c�CJI J 60 CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ (�. 0 Notary $ Technology Fee $ Structural Reviews $_ r- Training/Education Fee $ Double Fee $ Bond $ 500. TOTAL FEE NOW DUE $ (Rev1sed02/24/2014) 11�z4.2 tonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) _ Mortgage Lender's Address City State Zip Zi Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature NER or AGENT Signature i CONT The foregoing instrumef was acknowledged before me this The foregoing instrument was acknowledged before me this ( day of '1— 120 1'-7 , by � � day of • , 20 � '� , by lzo--A who is personally known to Daniel Essig w ally known to .:�Q�l�N�iil�ll.,. me or who has produced as me or who has produced ARM, I Sign: Print: Seal: Structural Review as Zoning Clerk (Revised02/24/2014) Mlsslon: To protect, promote & improve the health of all people in Florida through integrated state, county & community efforts. Rick Scott Governor Celeste Philip, MD, MPH Surgeon General and Secretary Vlslon : To be the Healthiest State in the Nation (Essig Pools, INC) 1800 NE 151 Street Miami, FL 33162 RE: Contingency Letter Application Document No: AP1309415 Centrax Permit Number: 13-SC-1793160 OSTDS Number: 161 NE 106 St Miami, FL 33138 Lot:14 Block:208 October 16, 2017 Subdivision: Dunnings Miami Shores Dear Applicant: This will acknowledge receipt of an application dated 10/04/2017 for a permit to use an existing onsite sewage treatment and disposal system located on the above referenced property. As per Architect site plan and the scope of work: NEW SWIMMING POOL INSTALLATION ONLY. No Part of the unobstructed area shall be subject to any alteration and also maintain the respective set back previously established. NO OBJECTION letter issued by Gerard Philizaire. From a review of your completed application, it has been determined that your existing system appears to meet the minimum standards of F.A.C. 64E-6 for the proposed use. It is approved for use with the plans submitted to this office. If this system should fail, causing an unsanitary condition to exist, steps must be taken to bring the system into compliance immediately. Department approval of the system does not guarantee satisfactory performance for any specific period of time. Any change in material facts which served as a basis for issuance of this approval requires the applicant to modify the permit application. Such modification may result in this approval being made null and void. Issuance of this approval does not exempt the applicant from compliance with other Federal, State, or Local Permitting required for development of this property. If you have any questions on this matter, please call our office at (305) 623-3500. Sincerely, Gerard Philizaire, Engineering Specialist II Florida Department of Health www.FloridasHealth.com in DADE COUNTY TWITTER:HealthyFLA 1725 NW 167 St, Opa Locka, FL 33056 FACEBOOK:FLDepartmentofHealth PHONE: (305) 623-3500 . FAX: (305) 623-3645 1 YOUTUBE: fldoh (Essig Pools, INC) Page two October 16, 2017 Enclosures cc: Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 SWIMMING POOL OWNER'S CERTIFICATION Date f L /1 Miami Shores Village Building & Zoning Department Attention: Building Official certify that I am the legal owner of the property described as O..^, .155 MSL,-- ws Ex�- wC. 2, V6 tlt - -3'r l,t- ►H eN(, zo & , located at In accordance with Section 33-12(f), Code of Metropolitan Dade County, I certify that I understand and agree that the swimming pool to be constructed at the above address cannot be used or filled with water until separate permit has been obtained for an approved safety barrier, and such barrier erected, inspected and approved. further understand that this certification, however, does not eliminate the need for obtaining a permit and erecting and approved barrier prior to final inspection and use of the M Legal Owner Note: This certification is to be submitted with a swimming pool permit app in duplicate. Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RESTRICTIVE COVENANT PROTECTIVE POOL ENCLOSURE KNOW ALL MEN BY THESE PRESENTS: WHEREAS, the undersigned --� -A., L %_ L is/are the fee simple owner(s) of the following described property situated and bed g in Miami Shores Village, Florida: Address: 1(& 1 W t to(. S 1 A/k,'et-,: 6 L- ,-5 F f 23 13g Whereas, the undersigned owner(s) 'S v desire to utilize said Lot(s) as a single building site, and the undersigned owner(s) do(es) hereby declare and agree as follows: I. That the property will not be used in violation of any ordinances of Miami Shores Village or Miami -Dade County now in effect or hereinafter enacted. II. That the purpose of the covenant is to induce Miami Shores Village to issue a permit for a pool where the required enclosure is not on the subject property where the pool is located. III. That if any of our adjoining neighbors remove any portion of their fence or wall, or if our/my property shall fail to meet code requirements for pool barriers, we, as owners will immediately install a protective enclosure to meet code requirements and will obtain a permit for such fence. IV. That, I/we, as owner(s) hold Miami Shores Village harmless for any negligence or injury that results from not having the enclosure. V. If enclosure belongs to said property, I agree to maintain & or replace said enclosure in the event that is damaged or removed by any case. NOW, THEREOF, for good and valuable consideration, the undersigned do(es) hereby declare that he/she will not convey or cause to be conveyed the title to the above property without requiring the successor in title to abide by all terms and conditions set forth herein. FURTHER, the undersigned declare(s) that this covenant is intended and shall constitute a restrictive covenant concerning the use, enjoyment and title to the above property and shall constitute a covenant running with the land ar>� binding upon the undersigned, his/her successors and assigns and may only be released by Miami Shores Village��► ? successors,�Rr7ccoWjn_Se of said Village then in effect. ��� 4( OWNER SING & PRINT that on this day personally appeared before men L ai :1 as identification and he/she acknowledge that he/she executed the foregoing, for purposes there in expressed. SWORN TO AND SUBSCRIBED before me on this 1�� day of (Revised 05/2209 •,Ar C044•Y , SO.PTE,V, Z A� b � w Miami Shores Village Building i Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 NOTICE OF REQUIREMENTS RESIDENTIAL SWIMMING POOL, SPA AND HOT TUB SAFETY ACT I (We) acknowledge that a new swimming pool, spa or hot tub will be constructed or installed at I G 1yyc 10 c.. 5 "t' Miami Shores, FL, and hereby affirm that one of the following methods will be used to meet the requirements of Chapter 515, Florida Statues and the Florida Building Code R4101.17. Please initial the method(s) to be used: The pool will be equipped with an approved safety pool cover that comp lies with ASTM F1346-91. (Submit Manufacturer's Specifications). • A continuous, one-piece (child) barrier meeting the requirements of Florida: ildi Cody R4101.17.1.15 will protect the pool perimeter. The plans shall show the fence location anjrpgtrpd of ; • • • • • , • •;, attachment, including one end that shall not be removable without the aid of tools. (Submg"4rujfacturer's . Specifications). 000000 • . • • ........ A combination of non -dwelling walls and fences (screen enclosure, child feDce,.rlaasonry .. . ..... ..:..' fence walls, chain link or wood fence, etc.) will protect t he pool perimeter. The plans must ra�oafy t he t pe'.' . • • 0:0 and locatio of all non dwelling walls. Florida Building Code, R4101.17.1 • • • • • • • Any combination of protection which incorporates dwelling walls with openings directly intV114 " . • � � •. pool perimeter and all windows and doors will be equipped with exit alarms complying witFiWrik Building • • • Code, R4101.17.1.9 (Submit Manufacturer's Specifications). • • Any combination of protection which incorporates dwelling walls with openings directly into the pool perimeter and all doors will be equipped with a self -latching device with positive mechanical latching/locking installed a min. 54" above the threshold. If this option is selected, submit plans showing all types and location of all perimeter protection. The plans must also show the location and type of all openings, and the hardware type for each location. (Submit Manufacturer's Specifications). In accordance with the Code, the pool may not be filled with water without compliance with the Private Swimming Pool Safety Requirements, and upon expiration of the permit, the pool shall be presumed to be unsafe. I understand that not having one of the above installed will constitute a violation of Chapter 515, F.S ., an d will be considered as committing a misdemeanor of the second degree, punishable ap provided in Section 775.082 or Section 75.083 F.S .This form must be signed �xthe ownerlage and a prim tractor. ,R'S SIGNM D DATE ESSIG ;, PRINT) = TAR :d m �y ��~ c . p � 961 '' M'rrter: 1;/��0PFL0RID1' %`\V ER'S S A ANDrDATE Y0R'F ........ • • gE TF� �y"r i d � .Goy�ru y//�, 1RORIDP SAFE POOL ALARM �i S187D SAFE POOL ALARM UPC:014575187011 ...... . ...... .... .... . . .... .... ..... ...... .. . ..... .. .. ... ...... . . . . ...... • One unit per single entry/opening (and/or with its screen by using the second set of sensors). Can Not be used for 2 windows next to each other. Magnetic Sensor Entry Alarm "Always On" Alarm Protection Adult Pass -Through Auto Reset Button Additional Pass -Through Button For Delayed Entry From Either side Door or Fence High Output-110-115 db Alarm WaterNVeather resistant Housing Intended For Interior or Exterior Use Magnetic Sensor For Additional Door/ Screen Door 9V Battery Operation (Not included) Low Battery LED Display Pool Guard Alarm USA Patent No. 5,473,310 and 6,727,819 ETL Approved Under UL 2017 Standards Unit Size: 4.75 x 1.625 x 1.75 " Pcs./20Ft.: 9,600 Pcs./ 40 Ft.: 19,680 Pcs./ 40 Ft. Hq.: 22,896 PROPERTY ADDRESS: 161 NE 106th Street Miami Shores, Florida 33138-2036 LEGAL DESCRIPTION: Lot 14, Block 208 of "DUNNING'S MIAMI SHORES EXTENSION NO. 2", according to the Plat thereof as recorded in Plat Book 41, Page 78 of the Public Records of Miami -Dade County, Florida FOLIO NUMBER: 11 2136 006 0380 (Miami -Dade County Public Records/Property Appraiser's Office) SURVEYOR'S NOTES: All distances as shown are based on the US Survey foot. The National Flood Insurance Rate Map for Florida, Community Panel No. 120652 (Village of Miami Shores) 12086 C, 0302 L, FIRM Date 09/11/2009 and Revised with an effective date of 09/11/2009, published by the United States Department of Housing and Urban Development, delineates the herein described land to be situated outside the Special Flood Hazard Area designated by the Federal Emergency Management Agency (FEMA). Subject property lies within Zone "X", areas determined to be outside the 0.2% annual chance floodplain. Survey done by occupation, physical evidence, the recovery of existing property corners, field measurements, calculations, adjacent plats and legal description provided to the surveyor and also from the Miami -Dade County Public Records/ Property Appraiser Office and no claims as to ownership are made or implied. The legal ownership of the fences and/or walls as shown hereon was not determined, and the locations as shown are based on the recovered boundary monumentation. CERTIFIED TO: • Jea Luc Roy • • • • Sanchez Vadillo, LLP 6 :. • •: • ' • Old Republic National Title Insurance Company "•;' Y ' • • • • • • • • • • •••• •••• ••••• GENERAL SURVEYOR'S NOTES: •"• • • • • • • • • • • I) -This survey was conducted for the purpose of a "Boundary Survey" only and is not intended to delineate the reg0fi tolylurisdiction" any federate stele] • regional or local agency, board, commission or other entity. 090000 • 2r The accuracy obtained by measurements and calculations on this survey, meets and exceeds the Minimum Tellinical Jandarcip reglyrements Jqr.%:0 suburban area (1 foot in 7,500 feet) as specified in Chapter 5J-17, Florida Administrative Code. 0 9 : • • • • • 3)-This Survey does not reflect or determine ownership. • • • • • • • • • 4rLegal Description subject to any dedications, limitations, retractions reservations or easements of record. • • • • • •. : • • 5rExamination of the Abstract of Title will have to be made to determine recorded instruments, if any affecting the property; search of Public Records not performed by this office. 6)-No effort was made by this office to locate any underground utilities and/or structures within or abutting the subject property. 7}This Survey has been prepared for the exclusive use the entities named hereon only and certifications hereon do not extend to any unnamed parties. 8)-This Survey was prepared for a Mortgage Transaction only; not to be used for design and/or construction purposes without the consent of this office. 9}Utility facilities within Utility Easements not noted as violations. 10)-Driveways or portions thereof within Roadways not noted as violations or encroachments. 11)-Foundations and/or footings underneath the ground surface that may cross beyond the boundary lines of the herein described parcel are not shown. 12}Fence ownership determines by visual means only (if any); Legal ownership not determined. 13}No search records was made by this firm beside the record plat; therefore we do not imply or accept responsibility for any Easement, Dedication or Limitation for which information was not furnished. 14)-Contact the appropriate authorities prior to any design work on the hereon -described parcel for Building and Zoning information. 15)-In some instances graphic representations have been exaggerated to more clearly illustrate the relationship between physical improvements and/or lot lines. In all cases dimensions shall control the location of the improvements over scaled positions. 16)-The dimensions and directions shown hereon are in substantial agreement with record and calculated values unless otherwise noted. 17} Obstructed corners are witnessed by improvements JORGE L. CABRERA Phone: 305-302-2522 PROFESSIONAL SURVEYOR & MAPPER 2852 S.W. 149th Place, Miami, Florida 33185 Fax: 305-207-9537 This is to certify to the above named firm and or persons that the "SKETCH OF BOUNDARY SURVEY" of the herein described property is true and correct to the best of my knowledge and belief as recently surveyed under my direction, also there are no visible encroachments other than those shown. Owner or his representative furnished the legal description contained herein. Other recorded instruments may affect this property. Surveyor has not examined the abstract of title. Locations of utilities on or adjacent to the property were not secured unless specifically requested by owner. I further certify that this map or plat meets the Standards of Practice and the Minimum Technical Standard Requirements, adopted by the Board of Professional Surveyors and Mappers, pursuant to Chapter 472.027 Florida Statutes, as set forth In Chapter 5J-17, Florida Administrative Code, under Sections 5J-17.051 and 5J-17.052 and is a "BOUNDARY SURVEY" as defined in Section 5J-17.050. JORGE L. CABRERA Date of Field Work: 04/14/2017 Job # 17-3979 This drawing Is the property of Jorge L. Cabrera Professional Surveyor & Mapper Reproductions of this drawing are not valid unless Signed and embossed with the surveyor's seal. Professional Surveyor & Mapper, # 6487 State of Florida NNEJ 0POR OF BOUNDARY BU'Ru E-'Y Y SITE SCALE: 1" = 20' 7.5' ALLEY PER 11 (P.B. 42, PG. 33) _ 10' ASPHALT PAVEMENT F.I.P. 3/4' 0 00' —F.I.P. 3/4" No I.D. 75.o No I.D. — —0.67' 0.18' 6' W.F. //�- ( — 7.5' ALLEY PER (P.B. 41, PG. 78) 0 10 20 40 1 inch = 20 ft. L 0 T 14, BLOCK 208 �••••; "'1:' • ••• r• 14.70' N .. .. be •LQ p o ... .. • ;mil �. -� v �•':•� b "� 7.20' 22.45' m • •: LOCATION MAP �v .. .•. :" NOT TO SCALE _ h LEGEND (C) = Calculated CL. = Clear � = Center Line CONC. = Concrete CBS. = Concrete Block Stucco A = Delta ENC. = Encroachment F.F.EL. = Finish Floor Elevation F.I.P. = Found Iron Pipe F.I.R. = Found Iron Rod F.N. = Found Nail F.N&D. = Found Nail & Disc I.D. = Identification L = Length (M) = Measured O/L = On Line t = Property Line (P) = Plat P.C. = Point of Curvature P.B. = Plat Book PG. = Page R = Radius (R) = Record R/W = Right of Way U.E. = Utility Easement 0:\&C-JO6 \17-3929-I61 A 106 ST\II-3929-161 HE 106 Si. g 4/20/2017 109:03 P4 T SYMBOLS AIR CONDITIONER ® CABLE TV KA CATCH BASIN q1L CONCRETE POLE ® ELECTRIC BOX QS MANHOLE ® WATER PUMP ® WATER HEATER ® WATER METER WOOD POLE EXISTING ELEVATION ' COVERED AREA --X— CHAIN LINK FENCE (C.L.F.) o METAL FENCE (M.F.) — off — OVERHEAD LINES 0 PLASTIC FENCE (P.F.) — WOOD FENCE (W.F.) x WIRE FENCE (WR.F.) 6 Ln r; M F.I.P. 3/4' No I.D. 90'20'10'(M) 50.00, ,M)(R) F.I.P. 3/4" No I.D. (BLOCK CORNER) w D- Z W N W Z r PROPERTY ADDRESS: 161 NE 106th Street Miami Shores, Florida 33138-2036 LEGAL DESCRIPTION: Lot 14, Block 208 of "DUNNING'S MIAMI SHORES EXTENSION NO. 2", according to the Plat thereof as recorded in Plat Book 41, Page 78 of the Public Records of Miami -Dade County, Florida FOLIO NUMBER: 11 2136 006 0380 (Miami -Dade County Public Records/Property Appraiser's Office) SURVEYOR'S NOTES: All distances as shown are based on the US Survey foot. The National Flood Insurance Rate Map for Florida, Community Panel No. 120652 (Village of Miami Shores) 12086 C, 0302 L, FIRM Date 09/11/2009 and Revised with an effective date of 09/11/2009, published by the United States Department of Housing and Urban Development, delineates the herein described land to be situated outside the Special Flood Hazard Area designated by the Federal Emergency Management Agency (FEMA). Subject property lies within Zone "X", areas determined to be outside the 0.2% annual chance floodplain. Survey done by occupation, physical evidence, the recovery of existing property corners, field measurements, calculations, adjacent plats and legal description provided to the surveyor and also from the Miami -Dade County Public Records/ Property Appraiser Office and no claims as to ownership are made or implied. The legal ownership of the fences and/or walls as shown hereon was not determined, and the locations as shown are based on the recovered boundary monumentation. CERTIFIED TO: Jea Luc Roy Sanchez Vadillo, LLP Old Republic National Title Insurance Company GENERAL SURVEYOR'S NOTES: 1)-This survey was conducted for the purpose of a "Boundary Survey" only and is not intended to delineate the regulatory jurisdiction of any federal, state, regional or local agency, board, commission or other entity. 2)- The accuracy obtained by measurements and calculations on this survey, meets and exceeds the Minimum Technical Standards requirements for a suburban area (1 foot in 7,500 feet) as specified in Chapter 5J-17, Florida Administrative Code. 3�This Survey does not reflect or determine ownership. 4rLegal Description subject to any dedications, limitations, retractions reservations or easements of record. 5)-Examination of the Abstract of Title will have to be made to determine recorded instruments, if any affecting the property; search of Public Records not performed by this office. 6)-No effort was made by this office to locate any underground utilities and/or structures within or abutting the subject property. 7)-This Survey has been prepared for the exclusive use the entities named hereon only and certifications hereon do not extend to any unnamed parties. 8)-This Survey was prepared for a Mortgage Transaction only; not to be used for design and/or construction purposes without the consent of this office. 9YUtility facilities within Utility Easements not noted as violations. 10)-Driveways or portions thereof within Roadways not noted as violations or encroachments. 11)-Foundations and/or footings underneath the ground surface that may cross beyond the boundary lines of the herein described parcel are not shown. 12)-Fence ownership determines by visual means only (if any); Legal ownership not determined. 13)-No search records was made by this firm beside the record plat; therefore we do not imply or accept responsibility for any Easement, Dedication or Limitation for which information was not furnished. 14)-Contact the appropriate authorities prior to any design work on the hereon -described parcel for Building and Zoning information. 15)-In some instances graphic representations have been exaggerated to more clearly illustrate the relationship between physical improvements and/or lot lines. In all cases dimensions shall control the location of the improvements over scaled positions. 16)-The dimensions and directions shown hereon are in substantial agreement with record and calculated values unless otherwise noted. 17)- Obstructed corners are witnessed by improvements JORGE L. CABRERA 5-302-2522 PROFESSIONAL SURVEYOR & MAPPER Phone: 30 2852 S.W.149th Place, Miami, Florida 33185 Fax: 305-207-207-9537 37 This is to certify to the above named firm and or persons that the "SKETCH OF BOUNDARY SURVEY" of the herein described property is true and correct to the best of my knowledge and belief as recently surveyed under my direction, also there are no visible encroachments other than those shown. Owner or his representative furnished the legal description contained herein. Other recorded instruments may affect this property. Surveyor has not examined the abstract of title. Locations of utilities on or adjacent to the property were not secured unless specifically requested by owner. I further certify that this map or plat meets the Standards of Practice and the Minimum Technical Standard Requirements, adopted by the Board of Professional Surveyors and Mappers, pursuant to Chapter 472.027 Florida Statutes, as set forth in Chapter 5J-17, Florida Administrative Code, under Sections 5J-17.051 and 5J-17.052 and is a "BOUNDARY SURVEY" as defined in Section 5J-17.050. JORGE L. CABRERA Date of Field Work: 04/14/2017 Job # 17-3979 REVISED TO UPDATE & SHOW NEW POOL: 10/18/2018 Job # 17-3979-A This drawing is the property of Jorge L. Cabrera Professional Surveyor & Mapper Reproductions of this drawing are not valid unless Signed and embossed with the surveyors seal. Professional Surveyor & Mapper, # 6487 State of Florida NNE9.01,10H OP BOUNDARY SURVERRY SCALE: 1" = 20' 7.5' ALLEY PER (P.B. 42, PG. 33) 10' ASPHALT PAVEMENT CCD _ �o Y SITE F.I.P. 3/4" — N 75.00 (M)(R) — No I.D. 0.18' 6' W.F. 0.67' 89'42'O6"(C) THIS AREA IS PART OF THE � v _ SUBJECT PROPERTY ,, r 'NE' I06T ST • 1 LEGEND (C) = Calculated SYMBOLS CL. = Clear AIR CONDITIONER � = Center Line CONC. = Concrete Tv CABLE TV CBS. = Concrete Block Stucco [A CATCH BASIN A = Delta c1L CONCRETE POLE ENC. = Encroachment F.F.EL. = Finish Floor Elevation ® ELECTRIC BOX F.I.P. = Found Iron Pipe SO MANHOLE F.I.R. = Found Iron Rod ® WATER PUMP F.N. = Found Nail F.N&D. = Found Nail & Disc WATER HEATER I.D. = Identification ® WATER METER L = Length qL WOOD POLE (M) = Measured 00 EXISTING ELEVATION O/L = On Line = Property Line -x COVERED AREA (P) = Plat x CHAIN LINK FENCE (C.L.F.) P.C. = Point of Curvature ❑ METAL FENCE (M.F.) P.B. = Plat Book off OVERHEAD LINES PG. = Page o PLASTIC FENCE (P.F.) R =Radius (R) =Record WOOD FENCE (W.F.) R/W = Right of Way WIRE FENCE (WR.F.) U.E. = Utility Easement ® CBS. WALL D:\JEG-JOPGE\12-3929-A-161 NE — ST\1 3929-A-161 NE - 5T 9 10/19/201 .3-5 PM EDT 9.88' L 0 T 14, BLOCK 208 o 2.3' ® a 52.10' � v , POOL v v v v vvvvv\ EQUIPMENT v v v v vvv\i� 14.70' �< \ / vv�Sv CD CD 7.20' vv �v 22.45' U ONE-STORY 10.65' RESIDENCE # 161 d- 13.29' wi N 2.40' C:)_ 3.82' 3.82' 9.86' `v 19.00' 0.26' 11.6' r— � M A _ _ �11 R _ _ _ 0 18. 20' F.I.P. 3/4" cl° ZE No I.D. o N CV O M 0 00 `5' SIDEWALK o� 25' PARKWAY r; - - _ 16' PAVEMENT 75' R/W. _ - N.E. 106th STREET r w a F.I.P. 3/4" No I.D. `r' 0.18' 7.5 ALLEY PER (P.B. 41, PG. 78) 13.27' 0 10 20 40 1 inch = 20 ft. DEC 6020 <L -- 8PPr7- - """'G gt % oI)EPT _ 2�101 V CQ O SUBJECT o Crn f r�r.rrrCIE WI ry Ar l v S7-A7 ANu�"r IJN .f�tL,r FEUERq, p0 —GJ Ar,nr,_. �O N � Q I W J D O/L Vw 90'20'10"(M) • • �F.I.P. 3/4" I ...... : ••.. No I.D. • 150.00, .••••• .... .. . F.I.P. 3/4" ; • ; • No I.D. • :..... (BLOCK CORNER) • • .. . .. . •. . r7 n JORGE L. CABRERA Professional Surveyor & Mapper, # 6487 State of Florida LAST REVISION: 10/18/2018