RF-18-914Miami Shores Village
10050 N.E. 2nd Avenue NE
Miami Shores, FL 33138-0000
Phone: (305)795-2204
Project Address
mit
Parcel Number
Issue Date: 4/18/2018
Permit NO. IMF-4-18-914
Permit Type: Roof
Work Classification: Tile
Permit Status: APPROVED
Expiration: 10/15/2018
Applicant
11300 NE 2 Avenue Number: Cor Jesus Cha 1121360000050-01
Miami Shores, FL 33138-0000 Block: Lot:
BARRY UNIVERSITY INC
Owner Information
Address
Phone
Cell
BARRY UNIVERSITY INC
11300 NE 2 Avenue
MIAMI SHORES FL 33161-6628
11300 NE 2 Avenue
MIAMI SHORES FL 33161-6628
Contractor(s)
NATIONS ROOFING LLC
Phone CeII Phone
(407)649-1333
Valuation:
Total Sq Feet:
$ 80,000.00
6760
Type of Work: Re Roof
Additional Info: TILE RE -ROOF PER CODE
Classification: Commercial
Scanning: 3
Fees Due
CCF
DBPR Fee
DCA Fee
Education Surcharge
Permit Fee - New Roof
Scanning Fee
Technology Fee
Total:
Amount
$48.00
$6.00
$4.00
$16.00
$400.00
$9.00
$64.00
$547.00
Pay Date
Invoice #
04/09/2018
04/18/2018
Pay Type
RF-4-18-67093
Credit Card
Credit Card
Amt Paid Amt Due
$ 50.00 $ 497.00
$ 497.00 $ 0.00
Available Inspections:
Inspection Type:
Up Lift Report
Tin Cap
Final Roof
Tile In Progress
Renailing Affidavit
Review Roof
Cap Sheet
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, P " M ING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT.
construction and zo
Aut
ce t h t t
erm. ,Ia
riteignatu =:Own r
Buil ng Depa
April 18, 2018
e foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
thorize the ab ve- red ntractor to do the work stated.
(A.A.rrd'4-K titer-- �j"(3April 18, 2018
Applicant / Contractor / Agent Date
ent Copy
1
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Ave, Miami Shores, Florida 33138
Tel: 305-795-2204 Fax: 305-756-8972
Inspection Number. INSP-000760-2018
Permit Number. RF-4-18-914
Scheduled Inspection Date: October 18, 2018
Inspector. Naranjo, Ismael
Owner. BARRY UNIVERSITY
Address: 11300 NE 2 AVE Cor Jesus Chape
Project
Permit Type: Roof
Inspection Type: Roofing Final
Work Classification: Tile
Phone Number.
Miami Shores, FL 331380000 Parcel Number. 1121360000050-01
BARRY UNIVERSITY
Contractor. NATIONS ROOFING LLC Phone Number. 4076491333
RICHARD NUGET
Building Department Comments
TILE RE -ROOF PER CODE
Checklist Item
General Comments
Passed
False
Comments
Passed
Failed
Correction
Needed
Re -Inspection
Fee
No Additional Inspections can be scheduled until
re -Inspection fee Is paid.
Inspector Comments
JESUS 561-506-7462
Page 23 of 38
October 17, 2018
For Inspections please call: 305-762-4949
BUILDING
PERMIT APPLICATION
❑BUILDING 0 ELECTRIC
❑PLUMBING ❑ MECHANICAL
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
.r F,TVED
Master Permit No. RP 8 -q / 4-
Sub Permit No.
1g ROOFING ❑ REVISION
PUBLIC WORKS ❑ CHANGE OF
CONTRACTOR
JOB ADDRESS: 1 I3 011) �j f �N YtU,Q,11LUU
City: Miami
Shores County:
Folio/Parcel#: I ' p(12c0- Ng)
Occupancy Type:
efir cu
Miami Dade
❑ EXTENSION ❑RENEWAL
❑ CANCELLATION ❑ SHOP
DRAWINGS
Zip: 3 1 iQ
Is the Building Historically Designated: Yes NO
Load: Construction Type: Flood Zone:
OWNER: Name (Fee Simple Titleholder):
Address: i t .8b
City: RA' a VIA,�
Tenant/Lessee Name:
BFE: FFE:
o - 3os ^ $q- 39ct�
rY1.irS )'l't j j e.-FF YQV Phone#: 305 t'IQS -45yy
PcvIAA kiL.-
State: %_
y h I 3 ya. ° arr.,
CONTRACTOR: Company Name: (ti-i (NI Sfl j� $Q,,.r-
Address: � � (� pL S i.Q Q,I 1--0
City: Or .t State: V.L.-
Zip: 3-,1 (0(
Phone#:
Phone#: S%(- gLito-
Zip: 3 a-02 y
Qualifier Name: 1 CV;t1r6t l\q4C k r Phone#: (pi-t'q p-, 1333
State Certification or Registration #: C.6C, 13a, co so, (0 Certificate of Competency #: CCU.. I3 a cos l {o
DESIGNER: Architect/Engineer: I) A-- Phone#:
Address: City:
Value of Work for this Permit: $ 8-0) Square/Linear Footage of Work:
Type of Work: ❑ Addition ❑ Alteration ❑ New
Description of Work: --n it re " r y - t i' C:ak(e •
State: Zip:
(0 6 sq-C+
Lg Repair/Replace ❑ Demolition
Specify color of color thru tile: To mot 4-r h . Qy iA+ r1)
Submittal Fee $ SO 1 d Permit Fee $ CCF $ CO/CC $
Scanning Fee $ Radon Fee $ DBPR $ Notary $
Technology Fee $ Training/Education Fee $ Double Fee $
Structural Reviews $ Bond $
TOTAL FEE NOW DUE $
(Revised02/24/2014)
Bonding Company's Name (if applicable)
1)4
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable) 60 DK
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature
OWNER or AGENT
The foregoing instrument was acknowledged before me this
L�(JiiN j
day of Iv�NA / , 20 1 a , by q day of �CLrc A , 20 ) c" , by
SUSAN RASNr4 Ak- who is personallvlsnr m tp l r ha rri Aj!v^ pit'',who is personally known to
Signature
CONTRACTOR
The foregoing instrument was acknowledged before me this
me or who has produced as me or who has produced as
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
Seal.
Afig
,Or nor :,
(e., Notary Public State of Florida
Jeffry J Yao
My Commission FF 168481
pd Expires 11/12/2018
*********
APPROVED BY
***********
identification and who did take an oath.
NOTARY PUBLIC:
Sign: Print: CIN 1)If pp
Seal:
•i•,••• \p
•0sse 81ATE 0? ' -, ,,
r6
Plans Examiner Zoning
(Revised02/24/2014)
Structural Review
Clerk
Property Search Application - Miami -Dade County
Page 1 of 1
Summary Report
Property Information
Folio:
11-2136-000-0050
Property Address:
11300NE2AVE
Miami Shores, FL 33161-6628
Owner
BARRY COLLEGE
Mailing Address
11300 NE 2 AVE LAVOIE BLDG 2ND
FL RM 204
MIAMI SHORES, FL 33161-6628
PA Primary Zone
8200 SCHOOLS & CHURCHES
Primary Land Use
7241 EDUCATIONAL/SCIENTIFIC -
EX : EDUCATIONAL - PRIVATE
Beds / Baths / Half
0/0/0
Floors
2
Living Units
66
Actual Area
Sq.Ft
Living Area
Sq.Ft
Adjusted Area
623,362 Sq.Ft
Lot Size
1,740,400 Sq.Ft
Year Built
1954
Assessment Information
Year
2017
2016
2015
Land Value
$6,961,600
$6,961,600
$6,961,600
Building Value
$38,439,360
$36,913,434
$33,497,476
XF Value
$2,607,248
$2,628,780
$2,554,483
Market Value
$48,008,208
$46,503,814
$43,013,559
Assessed Value
$48,008,208
$46,503,814
$43,013,559
Benefits Information
Benefit
Type
2017
20161
2015
Educational
Exemption
$48,008,208
$46,503,814
$43,013,559
Note: Not all benefits are applicable to all Taxable Values (i.e. County,
School Board, City, Regional).
Short Legal Description
36524140AC
SE1/4 OF NE1/4 LESS E35FT & LESS
W4OFT
LOT SIZE 1740400 SQUARE FEET
Generated On 4/9/2018
Taxable Value Information
2017
2016 2015
County
Exemption Value
$48,008,208
$46,503,814
$43,013,559
Taxable Value
$0
$0
$0
School Board
Exemption Value
$48,008,208
$46,503,814
$43,013,559
Taxable Value
$0
$0
$0
City
Exemption Value
$48,008,208
$46,503,814
$43,013,559
Taxable Value
Regional
$0
$0
$0
Exemption Value
$48,008,208
$46,503,814
$43,013,559
Taxable Value
$0
$0
$0
Sales Information
Previous Sale
Price] OR Book -Page
Qualification Description
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
Version:
https://www.miamidade.gov/propertysearch/
4/9/2018
2017 FLORIDA NOT FOR PROFIT CORPORATION ANNUAL REPORT
DOCUMENT# 711458
Entity Name: BARRY. UNIVERSIT_Y,_INC
Current Principal Place of Business:
11300 N.E. SECOND AVENUE
ROOM 105 FARRELL HALL
MIAMI, FL 33161
Current Mailing Address:
11300 N.E. SECOND AVENUE
ROOM 105, FARRELL HALL
MIAMI, FL 33161
FEI Number: 59-0624364
Name and Address of Current Registered Agent:
DUDGEON, DAVID
11300 NE SECOND AVE
LAVOIE HALL #209
MIAMI, FL 33161 US
FILED
Apr 27, 2017
Secretary of State
CC2519040112
Certificate of Status Desired: No
The above named entity submits this statement for the purpose of changing its registered office or registered agent, or both, in the State of Florida,
SIGNATURE:
Electronic Signature of Registered Agent
Officer/Director Detail :
Title S Title T
Name DUDGEON, DAVID Name �ROSENTHAL, SUSAN7
Address 11300 NE SECOND AVE Address 11300 N.E. SECOND AVENUE
City -State -Zip: MIAMI FL 33161 City -State -Zip: MIAMI FL 33161
Title D Title PD
Name BUSSEL, JOHN Name BEVILACQUA, SISTER LINDA
Address 11300 NE SECOND AVE Address 11300 NE SECOND AVE
City -State -Zip: MIAMI FL 33161 City -State -Zip: MIAMI FL 33161
Title VP
Name MURRAY, JOHN
Address 11300 N.E. SECOND AVENUE
City -State -Zip: MIAMI FL 33161
Date
I hereby certify that the information indicated on this report or supplemental report is true and accurate and that my electronic signature shall have the same legal effect as if made under
oath; that I am an officer or director of the corporation or the receiver or trustee empowered to execute this report as required by Chapter 617, Florida Statutes; and that my name appears
above, or on an attachment with all other like empowered.
SIGNATURE: DAVID DUDGEON
GENERAL 04/27/2017
COUNSEL/SECRETARY
Electronic Signature of Signing Officer/Director Detail Date
Perelvi
ROOF ASSEMBLIES A
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form.
• .., •
Section A (General Information) ' •.'•
•
Master Permit No. Process No, ""
Contractor's Name Nam) Ch S
Job Address I )36-b �j12
iJ
❑ Low Slope
❑ Asphaltic Shingles
O New roof ❑ Repair
Low Slope Roof Area (SF)
PrueuiL
CATEGORY
❑ Mechanically Fastened Tile
❑ Metal Panel/Shingles
❑ Prescriptive BUR-RAS 150
ROOF TYPE
0 Maintenance
ROOF SYSTEM INFORMATION
Steep Sloped Roof AREA (SSF)J, (00 Total (SF)—t0A26
• • • •
•••.
'...• .
(MV seSet•:� Q io ;,1)
• • •
• • • •
• ......
Mortaa✓Aandsive Set jilers
•
0 Wood Shingles/Shaft • •
[�' Reroofing 0 Recovering
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen-
sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
L
JL.
4
q�.
J4
LP
r
n1N1
•LtJ
AHr-
CF
nre
by
VII
axle
I;
OV D
JG
-)EP
r`,i P ECT TO 0LJ L Ir,i
rTt
41:1
. rrr
.91
.'
.
.....�
......1
.,
. •1
......,
1
1
1
i
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
INTERNATIONAL CODE COUNCIL
FLORIDA BUILDING CODE— BUILDING, 5th EDITION (2014) 15.37
Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License
Agreement. No further reproductions authorized.
1.02
1.031
1.02
CI
1.02
1.01
1.03
.02
1.02
1.01
1.02
1.03
NOTES
1.01 INSTALL NEW TILE ROOF SYSTEM
1.02 NOT IN CONTRACT
1.03 REPLACE ALL DETERIORATED SOFFIT & FASCIA TYP.
Revisions:
No 1 batc:9-14-17
Mr. Jeff Yao
CONSTRUCTION
NOTES
Cor Jesu Chard
A-3
Barry University: Cor Jesu Chapel - Roof Replacement Project Specifications
BARRY UNIVERSITY
"COR JESU CHAPEL"
11300 NE 2nd AVENUE
MIAMI SHORES, FLORID
NORTH-
m
•• ••• • • .. . • ••
•..•
• .••••O
- •
• ••••AgichMark
iWG GROUP. INC.
•A:3161 • 7j1 S. W. 86th Way. Dave. Pc ida 33328
ane; (14.54) 471-0E01 Ix: (854} 880-0070
• ..• •
•
•
• •• •. ••• • • •
• •
• • • • • • • • • •
• • • • • • • • • • •
• ••
• • •• •
••• •
•• •• • • • •••
•••
• • ••• • •
Page 76 of 78
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
SECTION 1525
HIGH -VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION
Florida Building Code 5th Edition (2014) • • • •
High -Velocity Hurricane Zone Uniform Permit Application Fortlt • • • • • • • • •
•• • •.•.
INSTRUCTION PAGE
000000
•
•
•••• ••..
••••• •••.•
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING•PERMIT .
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NO1410•I1ELOW::.. •
Roof System
Required Sections of the
Permit Application Form
••....
Attachment,' Required
See List•Below :.
Low Slope Application
A,B,C
1,2,3,4,6,6,7 . •
Prescriptive BUR-RAS 150
A,B,C
4,5,6,7 ••
Asphaltic Shingles
A,B,D
1,2,4,5,6,7
poncrete or Clay Tile
A,B,D,E
1,2,3,4,5,6,7
Metal Roofs
A,B,D
1,2,3,4,5,6,7
Wood Shingles and Shakes
A,B,D
1,2,4,5,6,7
Other
As Applicable
1,2,3,4,5,6,7
ATTACHMENTS REQUIRED:
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
•
•••.
•
••.
•
000000
•
•..••.
• •
••••..
• .
•.••.
. .
•••..
.••.•.
� •
••.•..
• •
•.••..
• •
15.36
INTERNATIONAL CODE COUNCIL
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014)
Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License
Agreement. No further reproductions authorized.
ROOF ASSEMBLIES AND.ROOFTOP STRUCTURES
1
1
1
1
1
Florida Building Code 5th Edition (2014) _
High -Velocity Hurricane Zone Uniform Permit Application Form.
I Section C (Low Slope Application)
I Fill in specific roof assembly components and identify
I manufacturer
I (Ifa component is not used, identify as "NA")
System Manufacturer.
1 '
Product Approval No.:
I Design Wind Pressures, From RAS 128 or Calculations:
I
P1: P2: P3:
Max. Design Pressure, from the specific product
1 approval system:
1
Deck:
Type:
1 Gauge/Thickness.
1
1
Anchor/Base Sheet Fastener/Bonding. Material:
1
1
1
1
1
1
1
Slope:
Anchor/Base Sheet & No. of Ply(s):
Insulation Base Layer.
Base Insulation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
' Top Insulation Size and Thickness:
1 Top Insulation Fastener/Bonding Material:
1
Base Sheet(s) & No. of Ply(s):
Base Sheet Fastener/Bonding Material:
PIy Sheet(s) & No. of Ply(s):
PIy Sheet Fastener/Bonding Mat: ial:
1
1
Top PIy:
15.38
INTERNATIONAL CODE COUNCIL
Top PIy Fastener/Bonding Materia: • ••
•• •
Surfacing:
•.••..
•
••.•.•
Fastener Spacing for Anchor/BasitShe •
•b •
Field: " oc @ Lap, # Rows
Perimeter: " oc @ Lap, #
Comer: " oc @ Lap, #
• •
••..
••••
•
•••.
•
•I••..
1 •
•1.•••
.
• •••.
'••. •
••.••
'.
• r�
• •• ••••
c':"� " og
• •
ws. �_�ee••.
• • •
•
Number of Fasteners Pe' nsulation Board:
ttachrn :,
••
•• •
• • •
..
1•
•
• .
1
Field P- 'meter Comer 1
Illustrate Compon - is Noted and Details as Applicable: 1
Woodblocking, tter, Edge Termination, Stripping, Flashing,
Continuous Cle• , Cant Strip, Base Flashing, Counterflashing, I
Coping, Etc.
,Indicate: Me n Roof Height, Parapet Height, Height of Base
Flashing, •mponent Material, Material Thickness, Fastener
Type, Fa ener Spacing or Submit Manufacturers Details that
Comply ith RAS 111 and Chapter 16. 1
FT.
Parapet
Height
FT.
Mean
Roof
Height
1
1
1
1
1
>1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) l
Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License
Agreement. No further reproductions authorized.
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Bullding°Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section D (Steep Sloped Roof System)
1
1
1
1
Roof System Manufacturer: n\/Q9j/r0l,
'Notice of Acceptance Number. 1 w — 6 1 101. 041 _ • • • • 1
•
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): •
•. • .•••
P1: P1: P1: ..:. I.
Deck Type:.
Roof Slope:
: 12
Ridge Ventlation?
iJoNe
Type Underlayment:
Insulation:
9r ooj.Q
Io
.•••
• •
.••.
••..
•..•
•••
• • • • •
•• .. •.••
• • •
. ••
•• •
•
.• •
• •
00 •
:00'0:
Fire Barrier:
Mean Roof Height: 1,5�
-
Fastener Type & Spacing:
Adhesive Type:
1"Qs na,+is -I'in fck3s
Sul I 21trp
Type Cap Sheet:
{�o 11l0(ss 11A MAX
Roof Covering:
1-1
LQ
Type & Size Drip
Edge:
31 3" 0116
1 •
1
1
1
1
1
1
1
1
i
1
1
1
1
1
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014)
INTERNATIONAL CODE COUNCIL
15.39
Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License
Agreement. No further reproductions authorized.
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section E (Tile Calculations) ,
For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mr. If the Mt values
are greater than or equal to the M, values, for each area of the roof, then the tile attachment method is acceptable, • • • • •
..•.
•.• •
Method 1 "Moment Based Tile Calculations Per RAS 127" • • • • • • • •
••
(P1: x X = ) - Mg: = M„ Product Approval Mt • • • •
•
. .
(P2: 4, = ) - Mg: = Mr,Product_Approval Mr
•
(P3: xX = ) - Mg: = M, Product Approval Mt ."". . • • • •. •
•... ..•.
Method 2 "Simplified Tile alculations Per Table Below"
Required Moment of Resistance (Mr) From Table Below'1.,$ r� Product Approval Mt LJ d , y
• .
.. •.
• •.
• . .
••..
Mr required Moment Resistance*
. • .
.
Mean Roof Height
Roof Slope
15'
20'
25'
30'
••
..
• •• • 40'
•
• •
..
•
2:12
34.4
36.5
38.2
39.7
42.2
• 4
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.
32.2
33.8
35.1
37.3
5:12
t28.4'�
30.1
31.6
32.8
34.9
6:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
25.9
27.1
28.2
30.0
.
..•
•
. .
.
•
• •
"Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and
Appeals.
I For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or
I equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable.
J
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Method 3 "Uplift Based Tile Calculations Per RAS 127"
(P1: x L = x w: _ ) - W: x cos 0 = Fr, Product Approval F'
(P2: x L = x w: _ ) - W: x cos 0 = Fa Product Approval F'
(P3: x L = x w: = ) - W: x cos 0 = Fri Product Approval F''
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
t
P1 or P2 or P3
RAS 127 Table 1 or by an engineering analysis pre-
pared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
0
Job Site
Aerodynamic Multiplier
X
Product Approval
Restoring Moment due to Gravity
M9
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
M9
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L = length W = width
Product Approval
All calculations must be submitted to the building official at the time of permit application. -,
15.40
INTERNATIONAL CODE COUNCIL
FLORIDA BUILDING CODE - BUILDING, 5th EDITION (2014)
Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License
Agreement. No further reproductions authorized.
SECTION 1524
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
....
1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide tfleasrier with
the required roofing permit, and to explain to the owner the content of the section. The proviiions of *diem R4402 ••
govem the minimum requirements and standards of the industry for roofing system install:diens. Additienatly, the
following items should be addressed as part of the agreement between the owner antthrcbt►tractor. The owner's• • • •
initial in the designated space indicates that the item has been explained. •"" ""•'
• • • . •
2. , _Renailing wood decks: When replacing roofing, the existing rgeotcrtqpf deck may have to .
•
be renailed in accordance with the current provisions of Section R4403. (The roof d>'ck is asuall;r.
•
concealed prior to removing the existing roof system). : •' •• '
.. • •. • •
•
•
•
.•• •
4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking
can be viewed from below. The owner may wish to maintain the architectural appearance; therefore,
roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of
maintaining the appearance.
6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is
not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this
discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow
scuppers in accordance with the requirements of Sections R4402, R4403 and 134F113.
anymadi
Owner/Agents Signature Date
13(xo 02141f41/i n ed
Property Address
Revised on 7/9/2009 LD;07/01/2015;
Contractor Signature
Date
Permit Number
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Entegra Roof Tile, LLC
1289 NE 9t' Ave
Okeechobee, FL. 34972 • •
•
This NOA is being issued under the applicable rules and regulations governing the use qf+v3 truction materials. The .
documentation submitted has been reviewed and accepted by Miami -Dade County RER-Piodxct Conttiol.SectionloU'e
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisctictitm (AHJ'j• • • •
This NOA shall not be valid after the expiration date stated below. The Miami -Dade Count}+Product C'odro1 Section 4iin.
Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve th;'i ht:to have this product or:
material tested for quality assurance purposes. If this product or material fails to perform in tit acccUtoil annet'tl •
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, inoilifsr., or suspend the Usie•oi:
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it•i•ditcrmined by •
Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
SCOPE:
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www. mi a mid ad e.2ov/ec o n o my
DESCRIPTION: Bermuda Concrete Flat Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-1120.06 and consists of pages 1 through 6.
The submitted documentation was reviewed by Gaspar J Rodriguez.
MIAMI-DADE COUNTY
APPROVED
NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Category:
Sub Category:
Material:
Roofing
Roofing Tiles
Concrete
1. SCOPE
This approves a roofing system using Entegra Flat Concrete Roof Tile, as manufactured Entegra Roof Tile, LLC
in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply. with pie Florida
Building Code for High Velocity Hurricane Zone. For use in the locations where :he I-hessure itdrementS,• •
determined by applicable Building Code, do not exceed the design pressure values obtain by catculations in.
compliance with RAS 127 using the values listed in section 4 herein. The attachments 1qi1ktions 141 be preQared
as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant
Entegra Flat Tile
Trim Pieces
Dimensions
Length = 16"
Width = 10"
1= varies
w = varies
varying thickness
2.1 MANUFACTURING LOCATION
1. Okeechobee, FL
2.2 EVIDENCE SUBMITTED
Test Agency
Redland Technologies
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
Test
Specifications
TAS 112
Type 3a
Class III
TAS 112
Test Identifier
7161-03
Appendix III
94-084
94-060A
25-7094-2
25-7094-8
25-7094-5
25-7183-6
. .
• • • •
....
. .
. ..
. . . . .
..• •. • • • •
•Prod• uct
•
•
Description • •
Flat profile, interlocnig, l igh pressure extr> ••;
concrete roof tile equipped with two xail holes.
For mechanical, mortar or adhesive set
applications.
Accessory trim, concrete roof pieces for use at
hips, rakes, ridges and valley terminations.
Manufactured for each tile profile.
• •
.
Test Name/Report
Static Uplift Testing
PA 102 & PA 102(A)
Static Uplift Testing
PA 101 (Mortar Set)
Static Uplift Testing
PA-101 (Adhesive Set)
Static Uplift Testing PA 102
(4" Headlap, Nails, Direct Deck, New
Construction)
Static Uplift Testing PA 102
(4" Headlap, Nails, Battens)
Static Uplift Testing PA 102
(4" Headlap, Nails, Direct Deck,
Recover/Reroof)
Static Uplift Testing PA 102
(2 Quik-Drive Screws, Direct Deck)
Date
Dec. 1991
May 1994
March, 1994
Oct. 1994
Oct. 1994
Oct. 1994
Feb. 1995
NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 2 of 6
2.2 EVIDENCE SUBMITTED
Test Agency
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
The Center for Applied Engineering,
Inc.
Atlanta'Testing & Engineering, Inc.
Professional Service Industries, Inc.
Celotex Corporation Testing Service
Celotex Corporation Testing Service
Walker' Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Nutting Engineers
American Test Lab of South Florida
MIAMIDADE COUNTY
APPROVED
Test Identifier
25-7183-5
25-7214-1
25-7214-5
7161-03
Appendix II
Letter Dated Aug. 1,
1994
P0631-01
Test Name/Report
Date
Static Uplift Testing Feb. 1995
PA 102
(2 Quik-Drive Screws, Battens)
Static Uplift Testing March, 1995
PA 102
(1 Quik-Drive Screw, Direct Deck)
Static Uplift Te .ting • • • Isrch, 1995
PA 102 ••••
(1 Quik-Drive Screw, Battesns)
Wind Tunnel Tegbig• •
PA 108 (Nail-Qfij • • •
Wind Tunnel Testi$r
PA 108 (Nail-( 4•:
Wind Tunnel Te,g,ipg..
PA 108 (Mortarett : • •
•
•
•••• Dec. 1991 •
.... ••
•
•
•••'Aug. 199rd.
• ••
• • •
....
• July 1994:
•
P0402 Withdrawal Resistance Testine.of scretiv ept. 1993
Project No. 307025
Test #MDC-77
R1.894
R2.894
R3.894
395-40011-1
520109-1
520111-4
520191-1
Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Calculations
13343.1
RT 1210.02-15
vs. smooth shank Mils • • • •• •• • •• •
Wind Driven Rain
PA 100
Physical Properties
PA 112
Physical Properties
PA 112
Static Uplift Testing
PA 101
Static Uplift Testing
PA 101
Aerodynamic Multiplier
25-7094
25-7496
25-7584
25-7804b-8
25-7804-4 & 5
25-7848-6
25-7183
Restoring Moment, Mg
Two Patty Adhesive Set System
TAS 112
TAS 112
'Oct. 1994
Aug. 1994
Feb 2004
Dec. 1998
March 1999
March 2004
Feb 1996
April 1996
December
1996
March 1995
March 2004
April 1999
05/06/08
12/17/15
NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 3 of 6
•
3. LIMITATIONS:
3:1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may
required, refer to applicable building code.
3:3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Miami -Dade Product Control
Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slopvlrtrleSs stated
otherwise by the underlayment material manufacturers published literature. • . • . ' • "
3.6 This acceptance is for wood deck applications. Minimum deck requirements sh4111);.ii complitrice with
applicable building code.•
4. INSTALLATION
.... ....
.
.... .
....
4.1 Entegra `Flat' Concrete Roof Tile and its components shall be installed in strict•oongpliance w• k is • tiami
Dade County Roofing Application Standard RAS 118, RAS 119; and RAS 120,E • •• ••
4.2 Data For Attachment Calculations.
. . .
.
Table 1: Average Weight (W) and Dimensions (I x w) •..•.•
Tile Profile
Weight-W (Ibf)
Length -I (ft)
Width-w (ft)
Entegra Flat Tile
9.7
1.33
.833
Table 2: Aerodynamic Multipliers - X (ft3)
Tile
X (ft3)
X (ft3)
Profile
Batten Application
Direct Deck Application
Entegra Flat Tile
0.189
0.205
Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf)
Tile
Profile
3":12"
4":12"
5":12" -
6":12"
Greater than
7":12"
Entegra Flat Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
6.53
6.97
6.43
6.86
6.29
6.71
6.14
6.54
5.97
6.35
MIAMI•DADE COUNTY
APPROVED
NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 4 of 6
Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf)
" for Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15/32" plywood)
Direct Deck
(min. 19/32" plywood)
Battens
Entegra Flat
Tile
2-10d Ring Shank Nails
30.9
38.1
17.2
1-10d Smooth or Screw
Shank Nail
7.3
9.8
4.9
2-10d Smooth or Screw
Shank Nails
14.0
18.8
7.4
1 #8 Screw
30.8
30.8
•••••48.2
2 #8 Screw
51.7
51.7 •.. • :
...?4.4 • •
1-10d Smooth or Screw
Shank Nail (Field Clip)
24.3
24.3
..:. 24.2 '
• •
1-10d Smooth or Screw
Shank Nail (Eave Clip)
19.0
19.0.•"'.
••••
.••••22.1 •
�••�� •-•
2-10d Smooth or Screw
Shank Nails (Field Clip)
35.5
35.5.,.. •
• •:. • 84.8
• .•
2-10d Smooth or Screw
Shank Nails (Eave Clip)
31.9
_ 31.9 • • •
: . ••.
• 32.2 •
•
.. . .. . .
. .• .
2-10d Ring Shank Nails'
50.3
65.5
• • • 48.3
1 Installation with a 4" tile headlap and fasterners are located a min. of 2'/z" from head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mt (ft-Ibf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
-
Minimum Attachment Resistance
Entegra Flat Tile
Adhesive
31.33
2 See manufactures component approval for installation requirements.
3 Flexible Products Company TileBond Average weight per patty 13.9 grams.
3MT" 2-Component Foam Roof Tile Adhesive AH-160. Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mt (ft-Ibf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Entegra Flat
Tile
3MT' 2-Component Foam Roof Tile Adhesive AH-160
118.94
3MT" 2-Component Foam Roof Tile Adhesive AH-160
4 Large paddy placement of 45 grams of 3MT" 2-Component Foam Roof Tile Adhesive AH-160
5 Medium paddy placement of 24 grams of 3MT' 2-Component Foam Roof Tile Adhesive AH-160
MIAMI-DADE COUNTY
APPROVED
NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 5 of 6
5. , LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
ENTEGRA FLAT TILE LABEL (LOCATED ON UNDERSIDE OF TILE •• • • •
•
• • •...
. . . .
BUILDING PERMIT REQUIREMENTS: • • • •
As required by the Building Official or the applicable Building Code in order to projierTy evaluatethe
installation of this system. This Notice of Acceptance on its own cannot be used topbtiin a buirc4in .permit.
MIAMI•DADE COUNTY
APPROVED
PROFILE DRAWING
ENTEGRA "FLAT" CONCRETE ROOF TILE
16' -)
16'
FIELD TILE
THICK BUTT TILE
END OF THIS ACCEPTANCE
. ..
. . . . .
..• .. • • • •
• •
• . •
•. • •. .
. • •
.
• •
.
• •
NOA No. 16-0112.07
Expiration Date: 06/07/21
Approval Date: 02/25/16
Page 6 of 6
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Polyglass USA Inc.
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
SCOPE:
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.¢ov/economy
. ..
. .
. ....
. . . •
This NOA is being issued under the applicable rules and regulations governing the use of ccrastruction.ra' erials. Tji, • ; •
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Proettet Control•Section to be .
used in Miami -Dade County and other areas where allowed by the Authority Having JurisilfCtfdil (AHJ)',
.... ....
This NOA shall not be valid after the expiration date stated below. The Miami -Dade Coun'duct CoSectitlrt • • • t�'>'cauld
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to Vie this •.
product or material tested for quality assurance purposes. If this product or material fails tp perfprm in,the accepted •
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately.revoke; Mddiiy, or .
suspend the use of such product or material within their jurisdiction. RER reserves the riglrt•to revoke tlri§, ceptance, •
if it is determined by Miami -Dade County Product Control Section that this product or material fails to Meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this:NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Semino.
MIAMI•DADE COUNTY
APPROVED
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 1 of 8
•
ROOFING COMPONENT APPROVAL
Category:
Sub -Category:
Material:
Roofing
Underlayment
SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Product
Polystick IR-Xe
Manufacturing
Location #1 & #2
Polystick Dual Pro
Manufacturing
Location #2
Polystick Tile Pro
Manufacturing
Location #2
Polystick TU Max
Manufacturing
Location #1 & #2
Polystick TU P
Manufacturing
Location #2
Polystick TU Plus
(Surface Printing)
Manufacturing
Location #1 & #2
Polystick MTS
Manufacturing
Location #2
Polystick MTS Plus
Manufacturing
Location #2
Elastoflex S6 G
Manufacturing
Location #2
MIAMI.DADE COUNTY
APPROVED
Dimensions
65' x 3'3 3/8"
Or65'x3'
60 mils thick
61' x 3'33/8"
60 mils thick
61' x 3'33/8"
60 mils thick
65'8" x 3'3-3/8"
60 mils thick
32' 10" x 3'33/8"
130 mils thick
65' x 3'33/8"
80 mils thick
65'8" x 3'33/8"
60 mils thick
65'8" x 3'33/8"
60 mils thick
32'10" x 3'3 %"
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103
TAS 103
TAS 103 and
ASTM D 6164
Test Product
Specification - Description • •
ASTM D 1970 A fine granular/sand top surface Self-adhe'Iflg, APP •
•
polymer modified, fiberglass reinforced, bytuminous• ••'.
•
sheet material for use as an ligglUtument it sloped goof •
assemblies. Designed as an ice.& rain shield. •
•. ••
A rubberized asphalt self-414 i14g, glass fljer/polyesM • •
reinforced waterproofing mei- brsne. Desi�ngr e$ as a
metal roofing and roof tile ijit t yment. •
• . • .
A rubberized asphalt self -adhering, glasnitef/polyaste
reinforced waterproofing mefttbraiie. De,gpN as a metat •
roofing and roof tile underlayment.
A rubberized asphalt self -adhering, polyester reinforced
waterproofing membrane. Designed as a a roof tile
underlayment.
A rubberized asphalt waterproofing membrane, glass-
fiber/polyester reinforced, with a granular surface
designed for use as a tile roof underlayment.
A rubberized asphalt self -adhering, glass-fiber/polyester
reinforced waterproofing membrane. Designed as a metal
roofing and roof tile underlayment.
•
•
••
A homogeneous, rubberized asphalt waterproofing
membrane, glass fiber reinforced with polyolefinic film
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
A homogeneous, rubberized asphalt waterproofing
membrane, glass fiber reinforced with polyolefinic film
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Polyester reinforced, SBS modified bitumen membrane
with a sanded back face and a granule top surface. For
use in roof tile underlayment systems.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 2 of 8
• 'MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED
Test Agency Test Identifier
Trinity I ERD
PRI Asphalt Technologies
Momentum Technologies, Inc.
P10870.09.08-R1
P10870.04.09
P33360.06.10
P33370.03.11
P33370.04.11
P36900.09.11
P37300.10.11
P40390.08.12-2
P37590.07.13-1
P45270.05.14
P46520.10.14
P44360.10.14
P43290.10.14
PLYG-SC 10130.06.16-3
PLYG-10130.06.16-1
PUSA-035-02-01
PUSA-055-02-02
PUSA-089-02-01
JX20H7A
RX14E8A
DX23D8B
DX23D8A
Test Name/Report
TAS 103
TAS 103/ASTM D4798 & G155
ASTM D1970
TAS 103 : • • •
•
ASTM D 1623
Date
12/04/08
04/13/09
. "'67/01/10
•••03/02/11
•.:.04/26/1J
TAS 103/ASTM D4798.8c44 i 5 •09/01 / 11
TAS 110/ASTM D4798 et D19.70 • • • • 4 0/ 19/ 14 .
ASTM D 1623 "6O8/07/12•:••.
ASTM D6164 • • : ••b7/02/13""
.•
•
•• ••
TAS 103, TAS 110 & ASTM A 1623
ASTM D 1623 : •
TAS 103 & TAS 1;10 • • •
ASTM D 1970 & TAS' 110'
TAS 103 & TAS 110
ASTM D1970 & TAS 110
TAS 103
TAS 103
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
. • ••
•
.05/12/14 .•
• 10/03/14....
• lb/07/1.4
.".'1D/17/1'4
• • t6/27/16
06/27/16
09/29/06
12/10/07
07/06/09
04/01/08
11/09/09
02/18/10
02/18/10
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
MIAMI.DADE COUNTY
APPROVED
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
MIAMI.DADE COUNTY
APPROVED
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening:
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro I Polystick T:UMaxi Vovlystick
TU P, Polystick TU Plus, Polystick MTS or Polystick S Plus,• self-ad�erEtl• •
•
Surfacing: See General Limitations Below. • •.:
Deck Type 1: Wood, non -insulated
•
•
.•
• .
•••• • • • .• • •
• •
.•.. •••.
Deck Description: Min. 19/32" plywood or wood plank • • • • • •
System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered •
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. : . . • .
• ..
• • •
...•
•
• •
•
• •
•• .• • •
•Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4d'•head lap. (for
base sheet only)
Membrane: Elastoflex S6 G, hot asphalt applied
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Membrane: Polystick TU Plus, self -adhered.
Surfacing:
MIAMI.DADE COUNTY
APPROVED
See General Limitations Below.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of 8
INSTALLATION REQUIREMENTS:
1. 'All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolliH'gthe
••.•
membrane from the center outward in both directions. • • •
.. . •.•.
5. For ridge applications, center the membrane and roll from the center outward in both di: eetions,. • :.
•
6. Roll or broom the entire membrane surface so as to have full contact with the surface, gi rrng special attentiQa...:
.. . .... •
to lap areas. • •
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly ebrrent erodai t Con•trdl.. •
Notice of Acceptance.
.. .. ..••
•
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flathing vpe shall be • •
pressed iri place and formed around the protrusion to ensure a tight fit. A second layer of Polys2i'bk'sliall be. .
applied over the underlayment. • • • • • •• ••
•
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, PolystickTU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Exposure Limitations (Days)
MTS
IR-Xe
Elastoflex
S6 G
TU
Plus
TU P
Tile Pro
Dual Pro
TU Max
MTS Plus
Winter Haven, FL
180
90
180
180
180
180
180
180
180
Hazelton, PA
N/A
90
N/A
180
N/A
N/A
N/A
180
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 5 of 8
MIAMI•DADE COUNTY
APPROVED
• Rule 61G20-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications. • • • •
• •
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblie�,•tiie •i iaximurn oof slope • •
shall be as follows: (See Table Below) .. • •
•
Tile
Profile
Polystick
MTS
Elastoflex
S6 G
Polystick TU Plus,
TU P, Tile Pro,
Dual Pro•
Polystick
TU Max
Polystia.
MTS'P1Yc'
•TPlus
Syit in (E3)) • •
M''SJJLs with,
•.:
Flat Tile
Prohibited
without battens
4:12
6:12
6:12
5:12-• • • •
• ' •
k:12
• • 4911111
Profiled
Tile
Prohibited
without battens
4:12
6:12
6:12
4Z2 �•„
" •
•_ •
•�.�T2 :...
•"•'• '
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for
all underlayments except Polystick MTS which shall be loaded onto battens.
w
a
0
t0
POLYSTICKTU Plus
MIAMI•DADE COUNTY
APPROVED
(6 Max. Per Stack)
12
•
DIP
•
DID
�••
•
•
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 6 of 8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for app rod al provided
that appropriate documentation is provided to detail compatibility of the products, wind uplift reSistee, anti f i@ . .
•
testing results. •
.
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTIGKMEMBRANES . .
.... ....
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECNIV APPJLI itTIONS: • • • •
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIc '
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood deck:' Ihtfallers.are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure ei eptabie.
Please also refer to applicable Product Data Sheets of the corresponding products. • • •
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 %" metal disk as
required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6 1/4"/12", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
MIAMI.DADE COUNTY
APPROVED
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 7 of 8
•
•
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical,SeNiQes
Department at 1 (800) 894-4563. •
•
14. Polyglass recommends that applicators follow good roofing practices and applicablepror edures as outlined by, • • • •
the National Roofing Contractors Association (NRCA). •
• • • •
• • • •
• •
• • • • • • • •
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPIMPAIC APF J.M T IONSI • : • • •
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMYNDATIC
END OF THIS ACCEPTANCE
MANMADE COUNTY
APPROVED
• • •
•
• •
• • •
• •
••
•• • •• •
• • •
•
••
• •
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 8 of 8
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
ICP Adhesives and Sealants, Inc.
12505 NW 44th Street
Coral Springs, FL. 33065
SCOPE:
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 315-2599
www.miamidade.gov/economv
This NOA is being issued under the applicable rules and regulations governing the use df��On$truction j terials. Thy
documentation submitted has been reviewed and accepted by Miami -Dade County RER-Eroduot ContraSection toles.
used in Miami Dade County and other areas where allowed by the Authority Having Jurisd ePi i.(AHJ). •
.... .... . .
This NOA shall not be valid after the expiration date stated below. The Miami -Dade Cortnt34 Product L.outfol Sectii.
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve•t •right to iray e•this prodhot•.
or material tested for quality assurance purposes. If this product or material fails to perforri'irtthe acceptedl•manner,•t •
manufacturer will incur the expense of such testing and the AHJ may immediately revokrMo'cirfy, or suspend the us'e•
of such product or material within their jurisdiction. RER reserves the right to revoke this aciartafice, if it is
determined by Miami -Dade County Product Control Section that this product or material faiLta meet t jv r.equirer1ents;
of the applicable building code. •.. ••••
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polyset® AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
MIAMI•DADE COUNTY
APPROVED
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 1 of 11
ROOFING COMPONENT APPROVAL:
Category:
Sub Category:
Materials:
Roofing
Roof tile adhesive
Polyurethane
SCOPE:
This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described
in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Rog
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile gys terns using IGP'
Adhesives Polyset® AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions
ICP Adhesives N/A
Polyset®AH-160
ICP Adhesives Foam N/A
Dispenser RTF1000
ICP Adhesives ProPack® N/A
30 & 100
Test
Specifications
TAS 101
.. •
.
. • ..
.
....
•
•
•
• .
.... • • • •
Produc"t•bt scripti0it • • •
.
•
. ..
. • • • •
.•• .. ••••
Two component ptiyi thane foam adhesive:
Dispensing Equipment •
Dispensing Equipment
•. .
. . .
.. •
.
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
1. Tomball, TX.
PHYSICAL PROPERTIES:
Property
Density
Compressive Strength
Tensile Strength
Water Absorption
Moisture Vapor Transmission
Dimensional Stability
Closed Cell Content
Test
ASTM D 1622
ASTM D 1621
Results
1.6 lbs./ft.3
18 PSI Parallel to rise
12 PSI Perpendicular to rise
ASTM D 1623 28 PSI Parallel to rise
ASTM D 2127 0.08 Lbs./Ft2
ASTM E 96 3.1 Perm / Inch
ASTM D 2126 +0.07% Volume Change @ -40° F., 2 weeks
+6.0% Volume Change @158°F., 100% Humidity, 2
weeks
ASTM D 2856 86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
MIAMI-DADE COUNTY
APPROVED
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2 of 11
EVIDENCE SUBMITTED:
Test Agency
Center for Applied Engineering
Miles Laboratories
Polymers Division
Ramtech Laboratories, Inc.
Southwest Research Institute
Trinity Engineering
Celotex Corp. Testing Services
Test Identifier
#94-060
257818-1PA
25-7438-3
25-7438-4
25-7438-7
25-7492
NB-589-631
9637-92
01-6743-011
01-6739-062b[ 1 ]
7050.02.96-1
P36700.04.12
P39740.02.12
528454-2-1
528454-9-1
528454-10-1
520109-1
520109-2
520109-3
520109-6
520109-7
520191-1
520109-2-1
Test Name/Report
TAS 101
TAS 101
SSTD 11-93
SSTD 11-93
SSTD 11-93
ASTM D 1623
.. .
ASTM E 108
ASTM E 108
ASTM E 84
TAS 114
•
....
. .
....
. .
.. ..
. . .
. .
ASTM D 1623 '..'
TAS 101
TAS 123
TAS 101
TAS 101
Date
04/08/94
12/16/96
10/25/95
11/02/95
12/12/95
•....
•
02,m /94
.
••••
•
44/J/93
. •
••••
;1V446/94
O IP115/95
•
• ;83/4**196
Q4/1.8/12
10/23/98
12/28/98
TAS 101 03/02/99
•
•
•
•
•
• •
•
•
•
•
•
.
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
MIAMI•DADE COUNTY
APPROVED
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
•
INSTALLATION:
1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH-160. -
2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance yvith J .00finai}ication
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and'Winjenance tipalet. • •
•• 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and license 11S 1eP Adh'ettves and
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicatm jo the auit1 i:ty haves..
. • •
jurisdiction. •••• ••••
•
5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is'i'6itiMd belored'iipplicatrA• • •
of any adhesive. The mix ratio between the "A" component and the "B" component Mitt e maintained between':'
1.0-1.15 (A): 1.0 (B). • •• •••••
•
•
•
6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispens@r IZ.1%1000br ICP
Adhesives ProPack® 30 & 100 dispensing equipment only. "•' '
•• •
7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset® AH-160 has been dispensed.
9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the
Placement Details' herein. Each generic tile profile requires the specific placement noted herein.
MANMADE COUNTY
APPROVED
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 4of11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
1Area
Placement Detail
Minimum Paddy Contact
Minimum Paddy Gram
Weight
Eave'Course - Flat, Low, High
Profiles
All Eave Course
17-23 sq. inches
45-65
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches
• Q•
Low Profile
#2
12-14 sq. inches
••
.'. ••3®•. •••.
High Profile
#2
17-19 sq. inches ...
• ••.. .
. • • •.30 • • • •
Flat, Low, High Profiles
#3
••••..
Two Paddys: 8-9 sq. inches at.
head of the 9-11 sq. inches of ....'
overlap • •
••
• • • 12 gram: p� r paddy... ,
• •
• • • . • .• •
• • • • .
--
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal .....17
edge) 20-25 sq. inches each:
bead ••
• •
_•••
gram per bean• • •:
• : • • . •
•. .
•34
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
gram u$der pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below.
MANMADE COUNTY;
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
MIAMI-DADE COUNTY
APPROVED
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
•
:•
•
•
•
•
•
•
•
•
ADHESIVE PLACEMENT DETAIL # 1
Nail through plastic coward
forms roqui?DO\ ,
Nal thwvghpiratic
Cr requiredF
IMdL.loyaw,[
2 in. wide
Battens
optbonal
10 In. in.
PladdirIBrnrrthl.l
t
Fesde
iffeephote
Ease closure
Grip edge
MIAMI-DADE COUNTY
APPROVED
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
2. Continue in same manner. appiEoxirfiately.l.7.
(109.7 cm2) — 23 (148.4 Crh2) Square irrlradhesive . •
contact with the underside of the tile.' • •
•.••
•...
. .
.. ..
• • •
Medium Profile / Double Pan tile •
•
• .•
•
....
• •
..•.
• ••
• • .
...•
•
•
•
••
•
••
1. Starting at the eave course, apply a'r N num
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 6of11
•
•
1
ADHESIVE PLACEMENT DETAIL # 2
Nail Airmail, plastic cement
when required)
Lom (mass
MIAMIOADE COUNTY
APPROVED
Paddy {e*n•ath 7110
Fascia
Flat/Low Profile Tile
•••• ••••
2. At the second course, applysa rp i�imum 2",(50.8m9
x 7" (177.8 mm) x 1" (25.47nrrr)•foamjdcLy onto ute••;
underlayment positioned as's'Iitfvn under•the•
•
strengthening rib closest to ife o:verlodc pf Vac tile
being set.
•• •• ••••
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cm2)
— 23 (148.4 cm2) square inch adhesive cedttcj with the
•underside of the tile. • • •
•••
• ••
••. •••
•
•
• • •
• •
•
3. Continue in same manner. Insure appVtifIrately 1
(64.5 cm2) - 12 (77.4 cm2) Square inch Adht:live . •
contact with the underside of the tile. • • •
Medium Profile / Double Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cm2) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
MIAMFDADE COUNTY
APPROVED
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 ji99!7 cm2) —
23 (148.4 cm2) square inclradl1esive corit
•.fi�f
.. with tiles • • • •
underside of the tile. :"' •
•
•
2. At the second course, applea.inimum.2'; (50.8m1• • •
x 7" (177.8 mm) x 1" (25.4•thm) foam paddy onto the •.
underlayment positioned as stidttn under tht pan •.:..'
portion of the tile closest to th eoverloclt'ef"the tile' •
being set. • •• ••
• ••
• • •
3. Continue in same manner insure approyinzately 17v• • •
(109.7 cm2) - 19 (122.6 cm2) square ind3 adhesive •
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8 of 11
MIAMI DADE COUNTY
APPROVED
ADHESIVE PLACEMENT DETAIL # 3
Flat/Low Profile The
Medium ProfileTlle
1. On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (101.6 mm) up from the eave
edge free of foam to preyeni the expaxded adhesiw. • •
from blocking the weep holes.• Insure ; • • • •'
•
approximately 17-23 in2rfd17-148.'4'M2) of
adhesive contact with theyperside of••• the tile
• •• • •
•••. ••••
•
• •• • •
•••••
2. Apply a 4" (101.6 mm)V 4" 6(101.6 inm')•x 1" (25.4
mm) foam paddy onto ire 4114erlaymerft just below.'
the second course line positioned fiatn4idy •
under the strengthening rikf fir flat til or undet t1i .:
pan portion of the tile, closest to th84.urt1tlock for
the second course tile to be installed. Insure
approximately 8-9 in2 (51.6-58.1 cm2) of adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
High Profile Tile
MIAMI•DADE COUNTY
APPROVED
3. Also apply a 2" (50.8 mm) x 4" (101.6mm) x'/4"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure awoximately
9 (58.1 cm2) - 11 (71 crui) square ina1i inesive
contact with the undersito.Sf the tile at vac overlap
and 7 (45.2 cm2) - 9 (58!+q ) square inch
adhesive contact with the tihtltrside of the tile at.
the head of the tile. Cor4tinue in sane?Milner. •
•••• ••••
• •
•••
••
• ••
• • •
••••
•
•
• •
• • ••
•
•
• • • • •
• •
• • •
•• •
•• •
• • •
•
•
• •
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
1) Place enough adhesive to achieve 65 to 70 sq. In.
in contact with the pan tile. •
2) Turn covers upside down. Place adhesive In
to 1 in. from outside edge of cover tile.
Then install the tile. Ensure 20 to
25 sq. in. contact area.
Underlayment
Eave dosure
(motar shown)
Weephole
Fascia Board
Steep pitch applications
when required)
Sheathing
Remove top portion of the eave course cover tile. Abut to second course of
pan tiles. Ensure eave end of pan and cover tiles are flush at eave line.
Two Piece Barrel - High Profile Tile
MIAMI•DADE COUNTY
APPROVED
••••
•
2. Continue in same manner brmging too pan ••
•...
courses up toward the pitg,e. Insure •
approximately 65 (4141,4• l) — 7A (i 1.6 cm•' • • • •
square inch adhesive•wrrtftct wi e Orin uhdersid;• •. •
of the pan tile. • • • • • •
• . • • •
3. Turn covers upside lamer posit the under:i.•;
of the tile. Apply a minimum 1" f .04:rnm) x 10" '
(254 mm) bead of adhesive directly on the inner
edge of each side of the cover tile. Leave
approximately 3/4" (19 mm) to 1" (25.4 mm)
from the outside edge of the tile, inward, free of
foam to allow for expansion.
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles• Aiipport eave
tiles from rocking until adkisive lias.achance49••••
cure. • •• ••'
•
4. Turn cover tile over after foam is applied and
place onto pan tile course. Insure a minimum of
20 (129 cm2) - 25 (161.3 cm2) square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11