Loading...
RF-18-3392Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Ave, Miami Shores, Florida 33138 Tel: 305-795-2204 Fax: 305-756-8972 Inspection Number: INSP-001760-2018 Permit Number: RF-11-18-3392 Scheduled Inspection Date: November 20, 2018 Inspector. Naranjo, Ismael Owner: NIRAT BEOHAR Address: 520 NE 92ND ST Project: Miami Shores, FL 33138 Contractor: PAUL BANGE ROOFING, INC. PAUL BANGE Permit Type: Roof Inspection Type: Roofing Final Work Classification: Repair Roof Phone Number: Parcel Number: 1132060141190 Phone Number: 9549817663 Building Department Comments TILE-REPAI TILE IN REPAIR Checklist Item General Comments Passed False Comments Inspector Comments Passed Failed Correction Needed Re -Inspection Fee No Additional Inspections can be scheduled until re -inspection fee is paid. November 19, 2018 For Inspections please call: 305-762-4949 Page 5 of 33 Miami Shores Village 10050 NE 2 Ave Miami Shores FL 33138 305-795-2204 Location Address Issue Parcel Number 108 018 Permit No.: RF-11-18-3392 Permit Type: Roof Work Classification: Repair Roof Permit Status: Approved Expiration: 05/07/2019 520 NE 92ND ST, Miami Shores, FL 33138 1132060141190 Contacts NIRAT BEOHAR 520 NE 92 ST, MIAMI SHORES, FL 33138 Owner PAUL BANGE ROOFING, INC. PAUL BANGE 7000 SW 21 Place, Davie, FL 33317 Business: 9549817663 Contractor shelly@paulbangeroofing.com Description: TILE-REPAI TILE IN REPAIR Fees Amount Application Fee - Other CCF DBPR Fee DCA Fee Education Surcharge Roofing Fee Scanning Fee Technology Fee $50.00 $1.80 $3.75 $2.50 $0.60 $200.00 $9.00 $6.25 Total: $273.90 Valuation: $ 2,250.00 Total Sq Feet: 100.00 Inspection Requests: 305-762-4949 Payments Total Fees Credit Card Amount Due: Date Paid 11/08/2018 Amt Paid $273.90 $273.90 $0.00 Building Department Copy In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accept g this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are requir:j or ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OW regu S AFFID construc d zoning. Futhermore, I authorize e above named contractor to do the work stated. fU. -e5\ \ t D►SCr *o , : I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws Authoriz:. Signature: Owner / Applicant / Contractor / Agent Date November 08, 2018 Page 2 of 2 BUILDING PERMIT APPLICATION' ❑BUILDING ❑ ELECTRIC Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECEIVED NOV 08 2018 014) FBC 20 Master Permit No. Q 18- 3 -i Sub Permit No. ROOFING ❑ REVISION ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF CONTRACTOR JOB ADDRESS: City: Folio/Parcel#: Occupancy Type: 5 c, Nf— Miami Shores County: Load: OWNER: Name (Fee Simple Titleholder): a WA..cz wi SLR 1 d 6 0.(no0 Pa wI 13cvw (Lo)re r-1 DESIGNER: Architect/Engineer: Address: City: Value of Work for this Permit: $ Type of Work: ❑ Addition ❑ Alteration ❑ Description of Work: ❑ EXTENSION El RENEWAL CANCELLATION ❑ SHOP DRAWINGS Miami Dade Zip. Is the Building Historically Designated: Yes Construction Type: Flood Zone: k IRAT g5-oH. Address: 5 -1 Z Sa— City: -t, quAA.: (i e r'et ` State: FO Tenant/Lessee Name: 11 ' A Email: CONTRACTOR: Company Name: Address: '-70 0 0 si,3 0 -1 P Lac P City: t� ovf r 'L Qualifier Name: Pa kik- • J3 R Phone#: State Certification or Registration #: C C C 0 3 3 tog 1 Certificate of Competency #: Phone#: State: (J I wiv NO L/ 0 BFE: FFE: Phone#: 3r 7 c Z3 2 3. eT 1 Zip: 33.'(3 Phone#: Phone#: isto S7 I -7(06 3 zip: .333 f 7 Square/Linear Footage of Work: New ❑ Repair/Replace 1 In 2 i r- State: Zip: /OD ❑ Demolition Specify color of color thru the:, Submittal Fee $ Scanning Fee $ Technology Fee $ Structural Reviews $ Permit Fee $ Radon Fee $ Training/Education Fee $ CCF $__ DBPR $ _--- CO/CC $ Notary $ Double Fee $ _ Bond $ TOTAL FEE NOW DUE $ IAA (Revised02/24/2014) ,t0 is Bonding • fLii"tihA` i `t1S�J7,�{+..dj Company's Name (if applicable] Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip rN u1.-4, tt Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. OWNER or AGENT The foregoing instrument was acknowledged before me this 9.9, day of Oda 1 ,by I�JdQ ,'w/ho is personally known to V me or who has produced )( as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: Ags Nathalie Se sera G 141240 S: July 24, 2022 mobiy CONTRACTOR The foregoing instrument was acknowledged before me this C9'> day of , 20 , by , who is personally known to me or who has produced V 1nOLAY as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: Nathalie Se sera S 00241240 '...r 'Ai.t� APPROVED BY Plans Examiner Zoning IRpvicrxin7/)4/XI4 Structural Review Clerk Property Search Application - Miami -Dade County Page 1 of 1 OFFICE OF THE P:i,�PERTY 4'PRAISER Summary Report Property Information Folio: 11-3206-014-1190 Property Address: 520 NE 92 ST Miami Shores, FL 33138-3157 Owner NIRAT BEOHAR Mailing Address 520 NE 92 ST MIAMI SHORES, FL 33138 USA PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds / Baths / Half 4/3/0 Floors 2 Living Units 1 Actual Area 3,575 Sq.Ft Living Area 3,092 Sq.Ft Adjusted Area 3,187 Sq.Ft Lot Size 12,700 Sq.Ft Year Built 1948 Assessment Information Year cs 2018 2017 2016 Land Value $380,819 $380,819 $317,517 Building Value ` $275,144 ) $277,760 $280,376 XF Value $36,380 $36,795 $37,210 Market Value $692,343 $695,374 $635,103 Assessed Value $692,343 $695,374 $635,103 Benefits Information Benefit Type 2018 2017 2016 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 2 PB 10-37 LOT 4 & 5 BLK 58 LOT SIZE 100.000 X 127 COC 23940-3146 10 2005 4 Generated On : 7/16/2018 Taxable Value Information 2018 2017 2016 County Exemption Value $0 $0 $0 Taxable Value $692,343 $695,374 $635,103 School Board Exemption Value $0 $0 $0 Taxable Value $692,343 $695,374 $635,103 City Exemption Value $0 $0 $0 Taxable Value $692,343 $695,374 $635,103 Regional Exemption Value $0 $0 $0 Taxable Value $692,343 $695,374 $635,103 Sales Information Previous Sale Price OR Book - Pa a 9 Qualification Description 09/14/2011 $600,000 27843 3162 Qual by exam of deed 10/01/2005 $0 23940- 3146 Sales which are disqualified as a result of examination of the deed 05/01/2000 $154,000 19107 0852 Sales which are qualified 02/01/1982 $89,900 11357- 1563 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http.//www.miamidade.goWinfo/disclaimerasp Version: https://www.miamidade.gov/propertysearch/ 7/16/2018 • ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section A (General Information) Contractor's Name/ lAnye/00-79;11 Job Address � O .B—Low Slope ❑ Asphaltic Shingles 0 New roof 11 Repair Process No. RECEIVED 0 NOV 08 18 ROOF CATEGORY ❑ Mechanically Fastened Tile ❑ Metal Panel/Shingles ❑. Prescriptive BUR-RAS 150 ROOF TYPE ❑ Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) 50 Steep Sloped Roof AREA (SSF) scdfY ion B (Roof Plan) 11 11 11 11 • • • •.••I• ,Er-Mortar/Adhesi• ve a Set L.s•: • • i •0 Wood S iig17s/Shakes ••• •..• • • • .... .... ••••f .. • •..•1 . 0 Reroofing • . • • 11 Recaw ring • .1 • • To• 3F i Q rj.••:• • • r� r fl. • •• • ...•• .. • .• • • • • Sketch Roof Plan: Illustrate all levels .and sections, roof drains, scuppers, overflow scuppers and overflow drains. sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ,100S f* <02-5-0 of cf2A/e. roc) . Include dimen- 1 a_ a C9 z 0 0 0 w.F 3 0 !3 7 f-rV? en 5R' I i 7 t f 0 a 0 0 0 11 11 9 11 0 0 a 0 A 11 1 "DeIvering Excellence Every Day" MIAMI-DADE COUNTY REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS It is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this form. The owner's initials in the designated space indicates that the item has been explained. NB 1. Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and wat4t iia ision performance standards. Aesthetics (appearance) are not a consideration with respect to.ywdcmanship,provision§r Aesthetic issues such as color or architectural appearance, that are not part of a zoning €ode% shodarfie addrossed. as part of the agreement between the owner and the contractor. . .... .... . . • 2. Renailing wood decks: When replacing roofing, the existing wood roof deer inay ha18 to be . . renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurri Eones),Qf Vhe Flgr1c4; Building Code. (The roof deck is usually concealed prior to removing the existing roof system). • • • . NB NB 3. Common roofs: Common roofs are those which have no visible delineatipn between.neigfiborir% • units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractoi altd/or • owner should notify the occupants of adjacent units of roofing work to be performed. NB 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. NB 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. NB 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. NB 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Owner's/Agent's Signature: Contractor's Signature: Property Address: Date: 11 Permit Number: 520 NE 92 ST, Miami Shores FL 18 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES 1 Florida Building Code 6th Edition 2017 High -Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steep Sloped Roof System) Roof System Manufacturer: Entregra Roof Tile Notice of Acceptance Number: 16-0112.06 • Minimum Design Wind Pressures, If Applicable (From RAS 127 or' • Calculations): P1: P2: P3: • • • . . . • • .... ICP ADHESIVE POLYSET AH-160 • . .. . . . .. . ..•. . • • • • • • • • ... . . • • •. • • • • Tie -In Repair Slope Tile to Flat Modified Bituman- self adhered Roof Slope: a 12 Steep Sloped Roof System Description Deck Type: • . • . • .• . • .• • . . . • .. 5/8 Plywood Type Underlayment: Ridge Ventilation? N/A Insulation: ASTM #30 Felt N/A Fire Barrier: Mean Roof Height: 14 N/A Fastener Type & Spacing: Adhesive Type: 1-1/4" RS Nails 6"oc lap, 2rows 0 12"oc Field Self Adhesive Type Cap Sheet: TU Max Polystick Roof Covering: Entrega Bella "S" Type & Size Drip Edge: N/A 15.34 FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) ICP Adhesives and Sealants, Inc. 12505 NW 44th Street Coral Springs, FL. 33065 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 www.mianudade.gov/economv This NOA is being issued under the applicable rules and regulations governing the use of cditstnfction !naiaalals. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to bb used in Miami Dade County and other areas where allowed by the Authority Having Jurisdict'ion.(CA1IJ). • • ..•• •• • This NOA shall not be valid after the expiration date stated below. The Miami -Dade Count/ 'P1 duct Coittibl Section• ; • • (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve tlfellglltto ham this product' • • • or material tested for quality assurance purposes. If this product or material fails to perform iri the accepted manner, the • manufacturer will incur the expense of such testing and the AHJ may immediately revoke, noccitt, or suspend the use • of such product or material within their jurisdiction. RER reserves the right to revokg this accepaatev; if it ills • determined by Miami -Dade County Product Control Section that this product or material fails t t nteet the rgquiremenl$' • • • of the applicable building code. • . . •.• . This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. APPROVED NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 a ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof file adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing, .:. Application Standard RAS 127. For use with approved flat, low, and high profile roof tile sysems asmg 1tP • Adhesives Polyset® AH-160. • PRODUCTS MANUFACTURED BY APPLICANT: padjug Dimensions TSAI . • • • .... •.... •. . . . ProductDyiWption , • • Specifications • •• • .. •.. • .. . ICP Adhesives N/A TAS 101 Two component polptintllpne foam•adhesive , Polyset®AH-160 ' ' i . . . . ICP Adhesives Foam N/A Dispensing Equipment.. • : • • • • • Dispenser RTF1000• '• ICP Adhesives ProPack® N/A Dispensing Equipment 30&100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 1.6 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft2 Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks ASTM D 2856 86% Closed Cell Content Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2of11 EVIDENCE SUBMITTED: Test AQencv Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier #94-060 257818-1PA 25-7438-3 25-7438-4 25-7438-7 25-7492 NB-589-631 9637-92 01-6743-011 01-6739-062b[1] 7050.02.96-1 P36700.04.12 P39740.02.12 Test Name/Renort TAS 101 TAS 101 SSTD 11-93 SSTD 11-93 SSTD 11-93 Date 04/08/94 12/16/96 10/25/95 11/02/95 17d1245 . ASTM D 1623 •.. 02/0134 . • • ASTM E 108 • • • • •. 0�/'SOf94 ASTM E 108 . . 1 lt1W194 ASTM E 84 01/1.6/;5 TAS 114 ASTM D 1623 TAS 101 TAS 123 . . • . . • • 03r1'r9e • • 04/J$/12 • 02/.1712 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 520109-2-1 TAS 101 03/02/99 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. .�. • 1.1k APPROVED NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofmg Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofmg t� ligation Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Mainjegance Booklet. • 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed ty Jo:Adherives imd Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicatgrs t 3 a authority having • jurisdiction. •• • • •• •• • •.• • 5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is re4Wdt1 before tfOlication of any adhesive. The mix ratio between the "A" component and the "B" component shall be iaintaineas etween •• •• Si • • 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam DispenserkTP1400 orJCP • Adhesives ProPack® 30 & 100 dispensing equipment only. •• •• •. • ••• • •• • 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. •• •••• • 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset® AH-160 has been dispensed. 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. 1.0-1.15 (A): 1.0 (B). • • • • • • •. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Area Minimum Paddy Gram Weight Eave Course - Flat, Low, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 . High Profile #2 17-19 sq. inches ' • • • 30 • Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at head of tile 9-11 sq. inches at , overlap 4 , ..12 gramt per paddy . • •. •••• •••• . . Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal , edge) 20-25 sq. inches each bead . , , ,17 grams a bead : 4. • • • . • . Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches • 44 gram wider pan • .. . •• • . . . .. • LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. APPROVED NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ... • • ... •••• • • • •••• . ADHESIVE PLACEMENT DETAIL # 1 Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 nun) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 im2) square n h iJkesive contact with the undersidtgl'thh tile. . • . . . . • .... .... . . . . • • • • .... Medium Profile / Double rah Ttle .. . . . . ..• • . . . . 1. Starting at the eave cour .e, apply a mini) 2" (50.8 mm) x 10" (254 maid' I! (25.4 mm) foam . paddy onto the underlayment positiontildaseshown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 nun) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. • . • • 2. At the second course, apply dthinhnum j51.13mm) x T' (177.8 mm) x 1" (25.41i fn 'Tham paddy onto the underlayment positioned as'showri under the • strengthening .• • • • s ... • . • being set. .. . . . . . . • 3. Continue in same manner. InvA,approximately 10" (64.5 cm2) -12 (77.4 cm2) square inch adhesive contact with the underside of the•tile. . • • • . .. . .. . • • . . . ..• . Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 min) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x T' (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) -14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. • • • • • • ••• • • 2. At the second course, applya iltmlwn 1'1 (36.13mm) • x 7" (177.8 nun) x 1" (25.4Vint'fbam paddy' onto they • underlayment positioned as.undeIt'ftp • portion of the tile closest to tfie o ierlock &VIE tile • • •• • being set. •••• ••• •• • •• • 3. Continue in same manner. Ipsure approxjmateay 17" (109.7 cm2) - 19 (122.6 cmsquare inclU8dltAlve contact with the underside oi:the rile. . • • • . . • • • • . NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8of11 ADHESIVE PLACEMENT DETAIL # 3 FlStti.ow ProlfloTlia RIedluni Praising OUNTY APPROVED 1. On the eave course only, apply a minimum 2" (50.8 nun) x 10" (254 nun) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep boles." Insure. approximately 17-23 in2 (149.7;148.4.cm2)•of adhesive contact with th%wi4erside otQf'tilb • .• .... .... . . 2. Apply a 4" (101.6 mm) x 4%f)01.6 mnr).x48 (25.4..... mm) foam paddy onto th%laymefttjpstbelow • • • • the second course line pdsltdded foam'idtly under the strengthening ;A%i flat tile, or under the '. pan portion of the tile, closesto the u�ideuloek for • the second course tile to bb jnstplled. lump • approximately 8-9 in2 (51.6-58.1 cm274tailhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9of11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) lb Psonislikt 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x'/," (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) -11 (71cm2) square inch adhesive contact with the underside of the tile ,tp@ 3verlap and 7 (45.2 cm2) - 9 (58.1 cm)squarer inch . adhesive contact with the underside oP41 artieat '. the head of the tile. Contprie: pi same manner. • .... . . .... .... .. . . . . .. .. ..• . • . • • • • • • ▪ •• • • ..• .. • • • • .. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL t)Mstaapoupbadbeotesto.ablest Ebto1os4.M Stowspiki► in tontactwhb Ow pas Ww &then fists ub 4iTurosayerssputa dawn:Plea4101okeis tot:in.fron ottsid.aalpaflyover tils. Then Wstoll the OW. Ensure2ato 95 sq. tn.(smutf area Rouwestoppatios atNaOMtows* coverOw Abut toword to of pan Wes. Emir* owe and of pan and taw taw one Bush waist Ina. Two Piece Barrel -High Profile The APPROVED Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. • • • • . • . 2. Continue in same mantle; bjging COO rift courses up toward the sid). insure . approximately 65 (419.4 ca — 70 (4S1.6 cm2) square inch adhesive contact with the anderside of the pan tile. •. •. •. • . . . ..• . • 3. Turn covers upside doiv rt'gxliosing the underside of the tile. Apply a minimum 1" (25.4►) x 10 (254 mm) bead of adheOv a dorectly on the inner: edge of each side of the cover tile. ! vex • approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 MIAMI/3 COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street; Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.ffov/economv Polyglass USA Inc. 1111 W. Newport Center Drive Deerfield Beach, FL 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of copstrge ton materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product eontroi Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdi :ttoi:;AHJ). • • • • . . This NOA shall not be valid after the expiration date stated below. The Miami -Dade County•pr!t�duct Conttol'Section • (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve trig ii, �i; to have i.tru:s product or material tested for quality assurance purposes. If this product or material fails to Betfggfi in the gegpted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately•revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right.to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or matelal fails to meet the • requirements of the applicable building code. . .. . .. . • • • This product is approved as described herein, and has been designed to comply with the Florida Building edde including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. . TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. .• ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Semino. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 1 of 8 • • ROOFING COMPONENT APPROVAL Category: Roofmg ,Sub -Category: Underlayment Material: SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick IR-Xe Manufacturing Location #1 & #2 Polystick Dual Pro Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 ['Pmystick-TU'Mja Manufacturing Location #1 & #2 Polystick TU P Manufacturing Location #2 Polystick TU Plus (Surface Printing) Manufacturing Location #1 & #2 Polystick MTS Manufacturing Location #2 Polystick MTS Plus Manufacturing Location #2 Elastoflex S6 G Manufacturing Location #2 Dimensions 65' x 3'3 3/8" Or65'x3' 60 mils thick 61' x 3'33/s" 60 mils thick 61' x 313/8" 60 mils thick 65'8" x 3'3-3/8" 60 mils thick 32'10" x 3'33/8" 130 mils thick 65' x 3'33/8" 80 mils thick 65'8" x 3'33/8" 60 mils thick 65'8" x 3'33/8" 60 mils thick 32'10" x 3'3 '/a" Test Saecification ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 and ASTM D 1970 TAS 103 TAS 103 TAS 103 and ASTM D 6164 Product Descrintion A fine granular/sand top surface self -adhering, APP polymer modified, fiberglass Tint -pried, bi inous sheet material for use as an undetlaytnent iodsjq}1 roof assemblies. Designed as an icb'& shield. . • A rubberized asphalt self-adh .riag,•$1ass-fiber/poesten reinforced waterproofing membrane. Designed tts a metal roofmg and roof tile undeiWiDent. . •' . • .. •. •• • • • . • . • . A rubberized asphalt selfadhezring,•lass-fiber/polyester • • reinforced waterproofmg mentbrane!Desi gli• •a metal' •• • • roofmg and roof tile underlaytent'. • .. • .• • • • A rubberized asphalt self adhering, polyester reinforced waterproofmg membrane. Designed as a a roof tile underlayment. A rubberized asphalt waterproofmg membrane, glass- fiber/polyester reinforced, with a granular surface designed for use as a tile roof underlayment. A rubberized asphalt self -adhering, glass-fiber/polyester reinforced waterproofmg membrane. Designed as a metal roofmg and roof tile underlayment. A homogeneous, rubberized asphalt waterproofmg membrane, glass fiber reinforced with polyolefmic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefmic film on the upper surface for use as an underlayment for metal roofmg, roof tile, slate tiles and shingle underlayment. Polyester reinforced, SBS modified bitumen membrane with a sanded back face and a granule top surface. For use in roof tile underlayment systems. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 2 of 8 MANUFACTURING PLANTS: 1. Hazelton, PA 2. Winter Haven, FL Test Ai encv Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. EVIDENCE SUBMITTED Test Identifier P10870.09.08-R1 P10870.04.09 P33360.06.10 P33370.03.11 P33370.04.11 P36900.09.11 P37300.10.11 P40390.08.12-2 P37590.07.13-1 P45270.05.14 P46520.10.14 P44360.10.14 P43290.10.14 PLYG-SC 10130.06.16-3 PLYG-10130.06.16-1 PUSA-035-02-01 PUSA-055-02-02 PUSA-089-02-01 JX20H7A RX 14E8A DX23D8B DX23D8A Test Name/Report Date TAS 103 12/04/08 TAS 103/ASTM D4798 & G155 04/13/09 ASTM D1970 07/01/10 TAS 103 : 0311W11 ASTM D 1623 : • • • • 04/26/11 TAS 103/ASTM D4798 & G155' :.43/01/11 TAS 110/ASTM D4798 &i5i417 10/19/11 •ASTM D 1623 • •• •Q81Q7/ 12 • ASTM D6164 ••.,•• •.QZQ2/13 TAS 103, TAS 110 & ASTM.D1623 .45/l2/14 ASTM D1623 •'.141/03/14 TAS 103 & TAS 11Q • • 10/07/14 ASTM D 1970 & TAS 110 • : .WQ,7/14 TAS 103 & TAS 110 • 06/27/16 ASTM D1970 & TAS 116 •:16/'La/16 TAS 103 09/29/06 TAS 103 12/10/07 TAS 103/ASTM D4798 & G155 07/06/09 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 04/01/08 11/09/09 02/18/10 02/18/10 • • • LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 17-0614.22 Expiration Date: 09/1321 Approval Date: 07/06/17 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Deck Description: System Type E(1): Anchor/Base Sheet: Fastening: Membrane: Surfacing: Deck Type 1: Deck Description: System Type E(2): Anchor/Base Sheet: Fastening: Membrane: Surfacing: Deck Type 1: Deck Description: System Type E(3): AnchorBase Sheet: Fastening: Ply Sheet: Membrane: Surfacing: MIAMI•DADE COUNTY APPROVED Wood, non -insulated Min. 19/32" plywood or wood plank Anchor sheet mechanically fastened to deck, membrane adhered One or more plies of ASTM D 226 Type II or ASTM D 2626. Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered. See General Limitations Below. • • • . • .. . • . Wood, non -insulated • Min. 19/32" plywood or wood plank •••. •• Anchor sheet mechanically fastened to deck, membrane adhered • • • • One or more plies of ASTM D 226 Type II or ASTM D 2626. • . • .. • • .... . . ••.. .. . . . . •s . • • • • . . Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a imn n m 4" head lap. (for base sheet only) • Elastoflex S6 G, hot asphalt applied See General Limitations Below. • • • . . .• . .•• . . .. . . . • Wood, non -insulated Min. 19/32" plywood or wood plank Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered. One or more plies of ASTM D 226 Type II or ASTM D 2626. Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for base sheet only) Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical laps. Polystick TU Plus, self -adhered. See General Limitations Below. • NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 4 of 8 • INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and sweep the deck thoroughly to re move any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the • membrane from the center outward in both directions. ' 5. For ridge applications, center the membrane and roll from the center outward in both2l t tibas. • • • 6. Roll or broom the entire membrane surface so as to have full contact with the surface: giving special attention ' to lap areas. • • • 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly .0 rent Pre i :Control Notice of Acceptance. • • •• • 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape•aliaif be • pressed in place and formed around the protrusion to ensure a tight fit. A second layfr e# t plystick shall be • • applied over the underlayment. ' • • • •• • GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofmg, roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofmg. Polystick IR-Xe may be used in all the previous assemblies listed except metal roofmg and roof tile systems. Polystick TU Max may be used in non-structural metal roofmg and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. • • • •• • • • • • • • Exposure Limitations (Days) MTS IR-Xe Elastoflex S6 G TU Plus TU P Tile Pro Dual Pro TU Max MTS Plus Winter Haven, FL 180 90 180 180 180 180 180 180 180 Hazelton, PA N/A 90 N/A 180 N/A N/A N/A 180 N/A All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 5 of 8 Rule 61G20-3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Pro is limited to mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications! 9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximutpxppfslope • .. . shall be as follows: (See Table Below) Tile Profile Polystick MTS Elastoflex S6 G Polystick TU Plus, TU P, Tile Pro, Dual••••• Pro Polystick TU Max Polystick; • • MTS PIit3 •' 1 • • • System (E3) • MTS Pita with : TVPtus Flat Tile Prohibited 4:12 6:12 6:12 5:1i .6:12 without battens • 4 • • • • •. . . • • • • Profiled Prohibited 4:12 6:12 6:12 4:12": •: 6:12 Tile without battens _ • • The above slope limitations can be exceeded only by using battens in accordance with tht Approveel•'Fj a System Notice of Acceptance and applicable Florida Building Code requirements. When battens are required', they shall be utilized during loading and installation of tiles. 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyg1a-ss' Tile loading detail below for loading procedure — two tiles laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for all underlayments except Polystick MTS which shall be loaded onto battens. 0 O. 0 10 N APPROVED; • • • • ..•• . . .•.. • •• • NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 6 of 8 • 11. Refer to prepared roofmg system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofmg products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. • . • •. • • . POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICI{ lE6IBRAil(ES' • • .• • PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECflJC.APPLICATTQ• NS. . • LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOM11188DATIONS, • • • • .. . W • 1. Polyglass does accept the direct application of Polystick underlayment membranes to od decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to Oilat:his is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. • 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edgeseam as per ▪ Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 '/s" metal aiseas. required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6 '/ "/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. • • • MIAMI•DADE COUNTY APPROVED NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 7 of 8 l 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. • • • . . . 14. Polyglass recommends that applicators follow good roofmg practices and applicable ppQ a .duj es as oatlnad by . . the National Roofmg Contractors Association (NRCA). • •••• •••• . . • • PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECtiefe APPLICA`tIbNS. • . LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOIV S E ATIONB: • : • END OF THIS ACCEPTANCE • . . • • •. • •. . . •. • • • • •. NOA No.: 17-0614.22 Expiration Date: 09/13/21 Approval Date: 07/06/17 Page 8 of 8 MIAMI-WIDE DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Entegra Roof Tile, LLC 1289 NE 9th Ave Okeechobee, FL 34972 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). ' • • This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Pro▪ duct • t ontrol Becton (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the MI ;g have thisproduct • or material tested for quality assurance purposes. If this product or material fails to perform in tl •accepted mppgr, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, moth fN,.gt'suspefld 413% Qse of such product or material within their jurisdiction. RER reserves the right to revoke this acceptaar.e, if it is .. . determined by Miami -Dade County Product Control Section that this product or material fails tnmeer the requiresrients of the applicable building code. • This product is approved as described herein, and has been designed to comply with the Florida Bty.kling Code including the High Velocity Hurricane Zone of the Florida Building Code. .. . .. . . . . .. • DESCRIPTION: Bela "High S" Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 14-1120.05 and consists of pages 1 through 5. The submitted documentation was reviewed by Gaspar J Rodriguez. MIAMFDADE COUNTY APPROVED NOA No.: 16-0112.06 Expiration Date: 07/13/21 Approval Date: 02/25/16 Page 1 of 5 • • . -a t ROOFING ASSEMBLY APPROVAL Cate2orv: Roofing Sub-Cateeorv: Roofing Tiles Material: Concrete Deck Type: Wood 1. SCOPE This approves a roofing system using Entegra Bella "High S" concrete roof tile as manufactured in Okeechobee, FL and described in Section 2 of this Notice of Acceptance. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. 2. PRODUCT DESCRIPTION • • . . . . . .. . . • Manufactured by Test Product:.. • Applicant Dimensions Specifications Description.. • • • • • • • • •••• •.•• Bella "High S" Trim Pieces Length = 16 '''A" Width = 13-'/4" Thickness =''A" 1= varies w = varies varying thickness 2.1 MANUFACTURING LOCATION 1. Okeechobee, FL TAS 112 Type 2 Class II TAS 112 High profile, interlocking, eattiptle0 conc;@te je2f tile equipped with two nail holes' Fbt mechanldal'mortar • or adhesive set applications. • • ' . •Accessory trim, concrete ro¢f pits for Ilse at hips, • • rakes, ridges and valley termlatiofis. • • • • • •• • .• . 2.2 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date The Center for Applied Engineering, 25-7094-(3, 6 & 9) Static Uplift Testing Oct. 1994 Inc. TAS 102 The Center for Applied Engineering, 25-7120-(1 & 2) Static Uplift Testing Nov. 1994 Inc. TAS 102 The Center for Applied Engineering, 25-7183-(3 & 4) Static Uplift Testing Feb. 1995 Inc. TAS 102 The Center for Applied Engineering, 25-7214-(3, 4, &7) Static Uplift Testing March, 1995 Inc. TAS 102 The Center for Applied Engineering, 25-7804-4 Static Uplift Testing Sep. 1996 Inc. TAS 102 Celotex Corporation Testing Services Celotex Corporation Testing Services Walker Engineering, Inc. MIAMI-DADE COUNTY APPROVED 520111-3 Static Uplift Testing Dec. 1998 TAS 101 520191-2-1 Static Uplift Testing March 1999 TAS 101 Calculations Aerodynamic Multiplier March 1999 NOA No.: 16-0112.06 Expiration Date: 07/13/21 Approval Date: 02/25/16 Page 2 of 5 '2.2 ' VIDENCE SUBMITTED Test A2encv Test Identifier Walker Engineering, Inc. Calculations IBA Consultants, Inc. 2421-94 American Test Lab of South Florida RT1210.03-15 Test Name/Report Restoring Moment ASTM C 1167 TAS 112-95 Date June 2007 June 2006 Dec 2015 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may be required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Miami -Dade Product • Control Section for review. • 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applicaaiar s Standards listed • • section 4.1 herein. •• 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the rociesi pe unless stated • • otherwise by the underlayment material manufacturers published literature. • • • • ▪ • • • • • • 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be •tbm• plianct•Wtth• • applicable building code. • • • •• • • •• 4. INSTALLATION • • • • • •• • • • • • 4.1 Entegra Sales, Inc.'s Bella "High S" concrete roof tile and its components slialf be; instaljecf jn.strict • compliance with Roofmg Application Standard RAS 118, RAS 119 and RAS 120. •• • 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Bella "High S" Tile 10.5 1.375 1.08 Table 2: Aerodynamic Multipliers - A (ft3) Tile A (ft3) A (ft3) Profile Batten Application Direct Deck Application Bella "High S" Tile 0.349 0.378 Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" Greater than 7":12" Bella "High S" Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13 MIAMI•DADE COUNTY APPROVED NOA No.: 16-0112.06 Expiration Date: 07/13/21 Approval Date: 02/25/16 Page 3 of 5 • i• T Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Bella "High S" Tile 2-10d Ring Shank Nails 28.6 41.2 19.4 1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 #8 Screw 20.7 20.7 18.1 2 #8 Screw 43.2 43.2 29.8 1-10d Smooth or Screw Shank Nail (Field Clip) 23.1 23.1 • . • . • 19.9 1-10d Smooth or Screw Shank Nail (Eave Clip) 29.3 29.3 •• • :Z�Q. 2-10d Smooth or Screw Shank Nails (Field Clip) 27.6 27.6 • `• • ` ` • `• 3e.6 ""b . 2-10d Smooth or Screw Shank Nails (Eave Clip) 38.1 38.1 ,• ••••'.'.' ,4.1.0 . 2-1Od Ring Shank Nails' 33.1 48.1 : • •: • 50.9 1. Installation with a 4" tile headlap and fasterners are located a min. of 2'/z" from head of tile. • •• • • •• • • • • • .•• • • • • •• • • Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) • • • for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Bella "High S" Tile Adhesive 29.32 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 10.7 grams. 3M- 2-Component Foam Roof Tile Adhesive AH-160 Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Bella "High S" Tile 3M'" 2-Component Foam Roof Tile Adhesive AH-160 66.53 3MT" 2-Component Foam Roof Tile Adhesive AH-160 38.74 3 Large patty placement of 63grams of 3M- 2-Component Foam Roof Tile Adhesive AH-160. 4 Medium patty placement of 24grams of 3M'• 2-Component Foam Roof Tile Adhesive AH-160. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Bella "High S" Tile Mortar Set5 24.5 5 Tile-Tite Roof Tile Mortar. MIAMI•DADE COUNTY APPROVED NOA No.: 16-0112.06 Expiration Date: 07/13/21 Approval Date: 02/25/16 Page 4 of 5 i 7'' 1r 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen in detail below, or following statement: "Miami -Dade County Product Control Approved". L OR ENTEG._. • • .. • • • • ENTEGRA SALES BELLA "HIGH S" CONCRETE TILE LABEL • • • (LOCATED UNDERNEATH TILE) ••••• • • • • • •• • • •••• •••• • • BUILDING PERMIT REQUIREMENTS: •• • • •• •• • •• • As required by the Building Official or the applicable Building Code in order to proprdy iluate the • installation of this system. This Notice of Acceptance on its own cannot be used to obtain abuilditg PROFILE DRAWING END OF THIS ACCEPTANCE MIAMI•DADE COUNTY APPROVED • • • • • •• • • • • •• • • • • •• • •. • NOA No.: 16-0112.06 Expiration Date: 07/13/21 Approval Date: 02/25/16 Page 5 of 5