RF-18-3392Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Ave, Miami Shores, Florida 33138
Tel: 305-795-2204 Fax: 305-756-8972
Inspection Number: INSP-001760-2018 Permit Number: RF-11-18-3392
Scheduled Inspection Date: November 20, 2018
Inspector. Naranjo, Ismael
Owner: NIRAT BEOHAR
Address: 520 NE 92ND ST
Project:
Miami Shores, FL 33138
Contractor: PAUL BANGE ROOFING, INC.
PAUL BANGE
Permit Type: Roof
Inspection Type: Roofing Final
Work Classification: Repair Roof
Phone Number:
Parcel Number: 1132060141190
Phone Number: 9549817663
Building Department Comments
TILE-REPAI TILE IN REPAIR
Checklist Item
General Comments
Passed
False
Comments
Inspector Comments
Passed
Failed
Correction
Needed
Re -Inspection
Fee
No Additional Inspections can be scheduled until
re -inspection fee is paid.
November 19, 2018 For Inspections please call: 305-762-4949
Page 5 of 33
Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
Location Address
Issue
Parcel Number
108
018
Permit No.: RF-11-18-3392
Permit Type: Roof
Work Classification: Repair Roof
Permit Status: Approved
Expiration: 05/07/2019
520 NE 92ND ST, Miami Shores, FL 33138
1132060141190
Contacts
NIRAT BEOHAR
520 NE 92 ST, MIAMI SHORES, FL 33138
Owner
PAUL BANGE ROOFING, INC.
PAUL BANGE
7000 SW 21 Place, Davie, FL 33317
Business: 9549817663
Contractor
shelly@paulbangeroofing.com
Description: TILE-REPAI TILE IN REPAIR
Fees
Amount
Application Fee - Other
CCF
DBPR Fee
DCA Fee
Education Surcharge
Roofing Fee
Scanning Fee
Technology Fee
$50.00
$1.80
$3.75
$2.50
$0.60
$200.00
$9.00
$6.25
Total: $273.90
Valuation: $ 2,250.00
Total Sq Feet: 100.00
Inspection Requests:
305-762-4949
Payments
Total Fees
Credit Card
Amount Due:
Date Paid
11/08/2018
Amt Paid
$273.90
$273.90
$0.00
Building Department Copy
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accept g this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are requir:j or ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OW
regu
S AFFID
construc d zoning. Futhermore, I authorize e above named contractor to do the work stated.
fU. -e5\ \ t D►SCr *o ,
: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws
Authoriz:. Signature: Owner / Applicant / Contractor / Agent Date
November 08, 2018
Page 2 of 2
BUILDING
PERMIT APPLICATION'
❑BUILDING ❑ ELECTRIC
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
RECEIVED
NOV 08 2018
014)
FBC 20
Master Permit No. Q 18- 3 -i
Sub Permit No.
ROOFING ❑ REVISION
❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF
CONTRACTOR
JOB ADDRESS:
City:
Folio/Parcel#:
Occupancy Type:
5 c, Nf—
Miami Shores County:
Load:
OWNER: Name (Fee Simple Titleholder):
a WA..cz wi SLR 1 d 6 0.(no0
Pa wI 13cvw (Lo)re r-1
DESIGNER: Architect/Engineer:
Address: City:
Value of Work for this Permit: $
Type of Work: ❑ Addition ❑ Alteration ❑
Description of Work:
❑ EXTENSION El RENEWAL
CANCELLATION ❑ SHOP
DRAWINGS
Miami Dade
Zip.
Is the Building Historically Designated: Yes
Construction Type: Flood Zone:
k IRAT g5-oH.
Address: 5 -1 Z Sa—
City: -t, quAA.: (i e r'et ` State: FO
Tenant/Lessee Name: 11 ' A
Email:
CONTRACTOR: Company Name:
Address: '-70 0 0 si,3 0 -1 P Lac P
City: t� ovf r 'L
Qualifier Name: Pa kik- • J3 R Phone#:
State Certification or Registration #: C C C 0 3 3 tog 1 Certificate of Competency #:
Phone#:
State:
(J I wiv
NO L/
0 BFE: FFE:
Phone#: 3r 7 c Z3 2 3. eT 1
Zip: 33.'(3
Phone#:
Phone#: isto S7 I -7(06 3
zip: .333 f 7
Square/Linear Footage of Work:
New ❑ Repair/Replace
1 In 2 i r-
State: Zip:
/OD
❑ Demolition
Specify color of color thru the:,
Submittal Fee $
Scanning Fee $
Technology Fee $
Structural Reviews $
Permit Fee $
Radon Fee $
Training/Education Fee $
CCF $__
DBPR $
_--- CO/CC $
Notary $
Double Fee $ _
Bond $
TOTAL FEE NOW DUE $
IAA
(Revised02/24/2014)
,t0 is
Bonding • fLii"tihA` i `t1S�J7,�{+..dj
Company's Name (if applicable]
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
rN u1.-4, tt
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
OWNER or AGENT
The foregoing instrument was acknowledged before me this
9.9, day of
Oda
1 ,by
I�JdQ ,'w/ho is personally known to
V me or who has produced )( as
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
Seal:
Ags
Nathalie Se sera
G 141240
S: July 24, 2022
mobiy
CONTRACTOR
The foregoing instrument was acknowledged before me this
C9'> day of , 20
, by
, who is personally known to
me or who has produced V 1nOLAY as
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
Seal:
Nathalie Se sera
S 00241240
'...r 'Ai.t�
APPROVED BY Plans Examiner Zoning
IRpvicrxin7/)4/XI4
Structural Review Clerk
Property Search Application - Miami -Dade County
Page 1 of 1
OFFICE OF THE P:i,�PERTY 4'PRAISER
Summary Report
Property Information
Folio:
11-3206-014-1190
Property Address:
520 NE 92 ST
Miami Shores, FL 33138-3157
Owner
NIRAT BEOHAR
Mailing Address
520 NE 92 ST
MIAMI SHORES, FL 33138 USA
PA Primary Zone
1000 SGL FAMILY - 2101-2300 SQ
Primary Land Use
0101 RESIDENTIAL - SINGLE
FAMILY : 1 UNIT
Beds / Baths / Half
4/3/0
Floors
2
Living Units
1
Actual Area
3,575 Sq.Ft
Living Area
3,092 Sq.Ft
Adjusted Area
3,187 Sq.Ft
Lot Size
12,700 Sq.Ft
Year Built
1948
Assessment Information
Year
cs 2018
2017
2016
Land Value
$380,819
$380,819
$317,517
Building Value
`
$275,144
)
$277,760
$280,376
XF Value
$36,380
$36,795
$37,210
Market Value
$692,343
$695,374
$635,103
Assessed Value
$692,343
$695,374
$635,103
Benefits Information
Benefit
Type
2018
2017
2016
Note: Not all benefits are applicable to all Taxable Values (i.e. County,
School Board, City, Regional).
Short Legal Description
MIAMI SHORES SEC 2 PB 10-37
LOT 4 & 5 BLK 58
LOT SIZE 100.000 X 127
COC 23940-3146 10 2005 4
Generated On : 7/16/2018
Taxable Value Information
2018
2017
2016
County
Exemption Value
$0
$0
$0
Taxable Value
$692,343
$695,374
$635,103
School Board
Exemption Value
$0
$0
$0
Taxable Value
$692,343
$695,374
$635,103
City
Exemption Value
$0
$0
$0
Taxable Value
$692,343
$695,374
$635,103
Regional
Exemption Value
$0
$0
$0
Taxable Value
$692,343
$695,374
$635,103
Sales Information
Previous
Sale
Price
OR Book -
Pa a
9
Qualification Description
09/14/2011
$600,000
27843
3162
Qual by exam of deed
10/01/2005
$0
23940-
3146
Sales which are disqualified as a result
of examination of the deed
05/01/2000
$154,000
19107
0852
Sales which are qualified
02/01/1982
$89,900
11357-
1563
Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http.//www.miamidade.goWinfo/disclaimerasp
Version:
https://www.miamidade.gov/propertysearch/
7/16/2018
•
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section A (General Information)
Contractor's Name/ lAnye/00-79;11
Job Address � O
.B—Low Slope
❑ Asphaltic Shingles
0 New roof
11 Repair
Process No.
RECEIVED 0
NOV 08 18
ROOF CATEGORY
❑ Mechanically Fastened Tile
❑ Metal Panel/Shingles
❑. Prescriptive BUR-RAS 150
ROOF TYPE
❑ Maintenance
ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) 50 Steep Sloped Roof AREA (SSF)
scdfY
ion B (Roof Plan)
11
11
11
11
•
• • •.••I•
,Er-Mortar/Adhesi• ve a Set L.s•: • • i
•0 Wood S iig17s/Shakes •••
•..• •
• •
.... .... ••••f
.. • •..•1
.
0 Reroofing • . • • 11 Recaw ring
• .1
• • To• 3F i Q rj.••:•
• • r� r fl. • •• •
...••
.. • .• •
• • •
Sketch Roof Plan: Illustrate all levels .and sections, roof drains, scuppers, overflow scuppers and overflow drains.
sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
,100S f* <02-5-0 of cf2A/e. roc) .
Include dimen-
1
a_
a
C9
z
0
0
0
w.F
3
0
!3
7
f-rV?
en 5R'
I
i
7
t
f
0
a
0
0
0
11
11
9
11
0
0
a
0
A
11
1
"DeIvering Excellence Every Day"
MIAMI-DADE COUNTY
REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS
It is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to
explain to the owner the content of this form. The owner's initials in the designated space indicates that the item
has been explained.
NB
1. Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane
Zone) are for the purpose of providing that the roofing system meets the wind resistance and wat4t iia ision
performance standards. Aesthetics (appearance) are not a consideration with respect to.ywdcmanship,provision§r
Aesthetic issues such as color or architectural appearance, that are not part of a zoning €ode% shodarfie addrossed.
as part of the agreement between the owner and the contractor. .
.... .... . .
•
2. Renailing wood decks: When replacing roofing, the existing wood roof deer inay ha18 to be . .
renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurri Eones),Qf Vhe Flgr1c4;
Building Code. (The roof deck is usually concealed prior to removing the existing roof system). • • •
.
NB
NB
3. Common roofs: Common roofs are those which have no visible delineatipn between.neigfiborir% •
units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractoi altd/or •
owner should notify the occupants of adjacent units of roofing work to be performed.
NB
4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be
viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail
penetrations of the underside of the decking may not be acceptable. The owner provides the option of
maintaining this appearance.
NB
5. Ponding water: The current roof system and/or deck of the building may not drain well and may
cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural
distress and may require the review of a professional structural engineer. Ponding may shorten the life
expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original
roofing system is removed. Ponding conditions should be corrected.
NB
6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not
overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if
overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance
with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing.
NB
7. Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be
reduced.
Owner's/Agent's Signature:
Contractor's Signature:
Property Address:
Date:
11
Permit Number:
520 NE 92 ST, Miami Shores FL
18
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
1
Florida Building Code 6th Edition 2017
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section D (Steep Sloped Roof System)
Roof System Manufacturer: Entregra Roof Tile
Notice of Acceptance Number: 16-0112.06
•
Minimum Design Wind Pressures, If Applicable (From RAS 127 or' •
Calculations):
P1: P2: P3:
• •
•
.
.
.
•
•
....
ICP ADHESIVE POLYSET AH-160
•
. ..
.
.
.
..
.
..•.
.
• • • •
•
•
•
•
...
.
.
• •
•.
•
• •
•
Tie -In Repair Slope
Tile to Flat
Modified Bituman-
self adhered
Roof Slope:
a 12
Steep Sloped Roof System Description
Deck Type:
• .
• . •
.• .
•
.• •
. . .
• ..
5/8 Plywood
Type Underlayment:
Ridge Ventilation?
N/A
Insulation:
ASTM #30 Felt
N/A
Fire Barrier:
Mean Roof Height: 14
N/A
Fastener Type & Spacing:
Adhesive Type:
1-1/4" RS Nails 6"oc lap, 2rows 0 12"oc Field
Self Adhesive
Type Cap Sheet:
TU Max Polystick
Roof Covering:
Entrega Bella "S"
Type & Size Drip
Edge:
N/A
15.34
FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
ICP Adhesives and Sealants, Inc.
12505 NW 44th Street
Coral Springs, FL. 33065
SCOPE:
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 315-2599
www.mianudade.gov/economv
This NOA is being issued under the applicable rules and regulations governing the use of cditstnfction !naiaalals. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to bb
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdict'ion.(CA1IJ).
•
•
..•• ••
•
This NOA shall not be valid after the expiration date stated below. The Miami -Dade Count/ 'P1 duct Coittibl Section• ; • •
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve tlfellglltto ham this product' • • •
or material tested for quality assurance purposes. If this product or material fails to perform iri the accepted manner, the •
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, noccitt, or suspend the use •
of such product or material within their jurisdiction. RER reserves the right to revokg this accepaatev; if it ills •
determined by Miami -Dade County Product Control Section that this product or material fails t t nteet the rgquiremenl$' • • •
of the applicable building code.
•
. .
•.• .
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polyset® AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
APPROVED
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 1 of 11
a
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof file adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described
in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing, .:.
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile sysems asmg 1tP •
Adhesives Polyset® AH-160. •
PRODUCTS MANUFACTURED BY APPLICANT:
padjug Dimensions TSAI
.
•
•
•
.... •.... •. .
. .
ProductDyiWption , • •
Specifications • •• •
.. •.. •
.. .
ICP Adhesives N/A TAS 101 Two component polptintllpne foam•adhesive ,
Polyset®AH-160 ' '
i . . . .
ICP Adhesives Foam N/A Dispensing Equipment.. • : • • • • •
Dispenser RTF1000•
'•
ICP Adhesives ProPack® N/A Dispensing Equipment
30&100
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
1. Tomball, TX.
PHYSICAL PROPERTIES:
Property Test Results
Density ASTM D 1622 1.6 lbs./ft.3
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Ft2
Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch
Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -40° F., 2 weeks
+6.0% Volume Change @158°F., 100% Humidity, 2
weeks
ASTM D 2856 86%
Closed Cell Content
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2of11
EVIDENCE SUBMITTED:
Test AQencv
Center for Applied Engineering
Miles Laboratories
Polymers Division
Ramtech Laboratories, Inc.
Southwest Research Institute
Trinity Engineering
Celotex Corp. Testing Services
Test Identifier
#94-060
257818-1PA
25-7438-3
25-7438-4
25-7438-7
25-7492
NB-589-631
9637-92
01-6743-011
01-6739-062b[1]
7050.02.96-1
P36700.04.12
P39740.02.12
Test Name/Renort
TAS 101
TAS 101
SSTD 11-93
SSTD 11-93
SSTD 11-93
Date
04/08/94
12/16/96
10/25/95
11/02/95
17d1245
.
ASTM D 1623 •.. 02/0134
.
•
•
ASTM E 108 • • • • •. 0�/'SOf94
ASTM E 108 . . 1 lt1W194
ASTM E 84 01/1.6/;5
TAS 114
ASTM D 1623
TAS 101
TAS 123
. . •
.
.
• • 03r1'r9e •
• 04/J$/12 •
02/.1712
528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1
520109-2-1
TAS 101 03/02/99
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
.�. • 1.1k
APPROVED
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
INSTALLATION:
1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH-160.
2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami -Dade County Roofmg Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofmg t� ligation
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Mainjegance Booklet.
• 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed ty Jo:Adherives imd
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicatgrs t 3 a authority having •
jurisdiction. •• • • •• •• • •.• •
5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is re4Wdt1 before tfOlication
of any adhesive. The mix ratio between the "A" component and the "B" component shall be iaintaineas etween
•• •• Si •
•
6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam DispenserkTP1400 orJCP •
Adhesives ProPack® 30 & 100 dispensing equipment only. •• •• •. •
••• • •• •
7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. •• ••••
•
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset® AH-160 has been dispensed.
9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details' herein. Each generic tile profile requires the specific placement noted herein.
1.0-1.15 (A): 1.0 (B).
•
•
•
•
•
•
•.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Minimum Paddy Contact
Area
Minimum Paddy Gram
Weight
Eave Course - Flat, Low, High
Profiles
All Eave Course
17-23 sq. inches
45-65
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches
30
Low Profile
#2
12-14 sq. inches
30 .
High Profile
#2
17-19 sq. inches '
• • • 30 •
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at
head of tile 9-11 sq. inches at ,
overlap
4
, ..12 gramt per paddy .
• •.
•••• •••• .
.
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal ,
edge) 20-25 sq. inches each
bead
.
, , ,17 grams a bead : 4.
• • •
.
• .
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
•
44 gram wider pan •
.. .
•• •
. . .
.. •
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
APPROVED
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
...
• •
...
••••
•
•
•
••••
.
ADHESIVE PLACEMENT DETAIL # 1
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 nun) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 im2) square n h iJkesive
contact with the undersidtgl'thh tile. . •
.
.
.
. •
.... .... . .
. .
• • • • ....
Medium Profile / Double rah Ttle
.. .
. . .
..•
•
. .
. .
1. Starting at the eave cour .e, apply a mini) 2"
(50.8 mm) x 10" (254 maid' I! (25.4 mm) foam .
paddy onto the underlayment positiontildaseshown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 nun) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 6 of 11
ADHESIVE PLACEMENT DETAIL # 2
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cm2)
— 23 (148.4 cm2) square inch adhesive contact with the
underside of the tile. • .
• •
2. At the second course, apply dthinhnum j51.13mm)
x T' (177.8 mm) x 1" (25.41i fn 'Tham paddy onto the
underlayment positioned as'showri under the •
strengthening .• • • • s ... • . •
being set.
.. .
. . . . .
•
3. Continue in same manner. InvA,approximately 10"
(64.5 cm2) -12 (77.4 cm2) square inch adhesive
contact with the underside of the•tile. .
•
•
•
.
.. . .. . • •
. . .
..•
.
Medium Profile / Double Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 min) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x T' (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) -14 (90.3 cm2) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile. • •
• • • •
••• • •
2. At the second course, applya iltmlwn 1'1 (36.13mm) •
x 7" (177.8 nun) x 1" (25.4Vint'fbam paddy' onto they •
underlayment positioned as.undeIt'ftp •
portion of the tile closest to tfie o ierlock &VIE tile • •
•• •
being set. •••• ••• •• • ••
•
3. Continue in same manner. Ipsure approxjmateay 17"
(109.7 cm2) - 19 (122.6 cmsquare inclU8dltAlve
contact with the underside oi:the rile. . • •
• . .
•
•
•
•
.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8of11
ADHESIVE PLACEMENT DETAIL # 3
FlStti.ow ProlfloTlia
RIedluni Praising
OUNTY
APPROVED
1. On the eave course only, apply a minimum 2" (50.8
nun) x 10" (254 nun) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (101.6 mm) up from the eave
edge free of foam to prevent the expanded adhesive
from blocking the weep boles." Insure.
approximately 17-23 in2 (149.7;148.4.cm2)•of
adhesive contact with th%wi4erside otQf'tilb
•
.•
.... .... . .
2. Apply a 4" (101.6 mm) x 4%f)01.6 mnr).x48 (25.4.....
mm) foam paddy onto th%laymefttjpstbelow • • • •
the second course line pdsltdded foam'idtly
under the strengthening ;A%i flat tile, or under the '.
pan portion of the tile, closesto the u�ideuloek for •
the second course tile to bb jnstplled. lump •
approximately 8-9 in2 (51.6-58.1 cm274tailhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9of11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
lb Psonislikt
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x'/,"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cm2) -11 (71cm2) square inch adhesive
contact with the underside of the tile ,tp@ 3verlap
and 7 (45.2 cm2) - 9 (58.1 cm)squarer inch .
adhesive contact with the underside oP41 artieat '.
the head of the tile. Contprie: pi same manner. •
....
. .
.... ....
.. .
. . .
.. .. ..•
.
•
.
•
•
• •
•
•
▪ ••
• •
..• .. • • •
• ..
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
t)Mstaapoupbadbeotesto.ablest Ebto1os4.M Stowspiki►
in tontactwhb Ow pas Ww &then fists ub
4iTurosayerssputa dawn:Plea4101okeis
tot:in.fron ottsid.aalpaflyover tils.
Then Wstoll the OW. Ensure2ato
95 sq. tn.(smutf area
Rouwestoppatios atNaOMtows* coverOw Abut toword to of
pan Wes. Emir* owe and of pan and taw taw one Bush waist Ina.
Two Piece Barrel -High Profile The
APPROVED
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocking until adhesive has a chance to
cure. •
•
• •
. • .
2. Continue in same mantle; bjging COO rift
courses up toward the sid). insure .
approximately 65 (419.4 ca — 70 (4S1.6 cm2)
square inch adhesive contact with the anderside
of the pan tile.
•. •.
•. •
. . .
..•
.
•
3. Turn covers upside doiv rt'gxliosing the underside
of the tile. Apply a minimum 1" (25.4►) x 10
(254 mm) bead of adheOv a dorectly on the inner:
edge of each side of the cover tile. ! vex •
approximately 3/4" (19 mm) to 1" (25.4 mm)
from the outside edge of the tile, inward, free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan tile course. Insure a minimum of
20 (129 cm2) - 25 (161.3 cm2) square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11
MIAMI/3
COUNTY
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street; Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.ffov/economv
Polyglass USA Inc.
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of copstrge ton materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product eontroi Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdi :ttoi:;AHJ). •
•
•
•
.
.
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County•pr!t�duct Conttol'Section •
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve trig ii, �i; to have i.tru:s
product or material tested for quality assurance purposes. If this product or material fails to Betfggfi in the gegpted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately•revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right.to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or matelal fails to meet the •
requirements of the applicable building code.
.
.. . .. .
• • •
This product is approved as described herein, and has been designed to comply with the Florida Building edde
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
.•
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Semino.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 1 of 8
•
•
ROOFING COMPONENT APPROVAL
Category: Roofmg
,Sub -Category: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Product
Polystick IR-Xe
Manufacturing
Location #1 & #2
Polystick Dual Pro
Manufacturing
Location #2
Polystick Tile Pro
Manufacturing
Location #2
['Pmystick-TU'Mja
Manufacturing
Location #1 & #2
Polystick TU P
Manufacturing
Location #2
Polystick TU Plus
(Surface Printing)
Manufacturing
Location #1 & #2
Polystick MTS
Manufacturing
Location #2
Polystick MTS Plus
Manufacturing
Location #2
Elastoflex S6 G
Manufacturing
Location #2
Dimensions
65' x 3'3 3/8"
Or65'x3'
60 mils thick
61' x 3'33/s"
60 mils thick
61' x 313/8"
60 mils thick
65'8" x 3'3-3/8"
60 mils thick
32'10" x 3'33/8"
130 mils thick
65' x 3'33/8"
80 mils thick
65'8" x 3'33/8"
60 mils thick
65'8" x 3'33/8"
60 mils thick
32'10" x 3'3 '/a"
Test
Saecification
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103 and
ASTM D 1970
TAS 103
TAS 103
TAS 103 and
ASTM D 6164
Product
Descrintion
A fine granular/sand top surface self -adhering, APP
polymer modified, fiberglass Tint -pried, bi inous
sheet material for use as an undetlaytnent iodsjq}1 roof
assemblies. Designed as an icb'& shield.
. •
A rubberized asphalt self-adh .riag,•$1ass-fiber/poesten
reinforced waterproofing membrane. Designed tts a
metal roofmg and roof tile undeiWiDent. . •' . •
.. •. •• •
•
•
.
•
.
• .
A rubberized asphalt selfadhezring,•lass-fiber/polyester • •
reinforced waterproofmg mentbrane!Desi gli• •a metal' •• • •
roofmg and roof tile underlaytent'. •
.. • .• • • •
A rubberized asphalt self adhering, polyester reinforced
waterproofmg membrane. Designed as a a roof tile
underlayment.
A rubberized asphalt waterproofmg membrane, glass-
fiber/polyester reinforced, with a granular surface
designed for use as a tile roof underlayment.
A rubberized asphalt self -adhering, glass-fiber/polyester
reinforced waterproofmg membrane. Designed as a metal
roofmg and roof tile underlayment.
A homogeneous, rubberized asphalt waterproofmg
membrane, glass fiber reinforced with polyolefmic film
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
A homogeneous, rubberized asphalt waterproofing
membrane, glass fiber reinforced with polyolefmic film
on the upper surface for use as an underlayment for metal
roofmg, roof tile, slate tiles and shingle underlayment.
Polyester reinforced, SBS modified bitumen membrane
with a sanded back face and a granule top surface. For
use in roof tile underlayment systems.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
Test Ai encv
Trinity I ERD
PRI Asphalt Technologies
Momentum Technologies, Inc.
EVIDENCE SUBMITTED
Test Identifier
P10870.09.08-R1
P10870.04.09
P33360.06.10
P33370.03.11
P33370.04.11
P36900.09.11
P37300.10.11
P40390.08.12-2
P37590.07.13-1
P45270.05.14
P46520.10.14
P44360.10.14
P43290.10.14
PLYG-SC 10130.06.16-3
PLYG-10130.06.16-1
PUSA-035-02-01
PUSA-055-02-02
PUSA-089-02-01
JX20H7A
RX 14E8A
DX23D8B
DX23D8A
Test Name/Report Date
TAS 103 12/04/08
TAS 103/ASTM D4798 & G155 04/13/09
ASTM D1970 07/01/10
TAS 103 : 0311W11
ASTM D 1623 : • • • • 04/26/11
TAS 103/ASTM D4798 & G155' :.43/01/11
TAS 110/ASTM D4798 &i5i417 10/19/11
•ASTM D 1623 • •• •Q81Q7/ 12 •
ASTM D6164 ••.,•• •.QZQ2/13
TAS 103, TAS 110 & ASTM.D1623 .45/l2/14
ASTM D1623 •'.141/03/14
TAS 103 & TAS 11Q • • 10/07/14
ASTM D 1970 & TAS 110 • : .WQ,7/14
TAS 103 & TAS 110 • 06/27/16
ASTM D1970 & TAS 116 •:16/'La/16
TAS 103 09/29/06
TAS 103 12/10/07
TAS 103/ASTM D4798 & G155 07/06/09
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
04/01/08
11/09/09
02/18/10
02/18/10
•
•
•
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
NOA No.: 17-0614.22
Expiration Date: 09/1321
Approval Date: 07/06/17
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1:
Deck Description:
System Type E(1):
Anchor/Base Sheet:
Fastening:
Membrane:
Surfacing:
Deck Type 1:
Deck Description:
System Type E(2):
Anchor/Base Sheet:
Fastening:
Membrane:
Surfacing:
Deck Type 1:
Deck Description:
System Type E(3):
AnchorBase Sheet:
Fastening:
Ply Sheet:
Membrane:
Surfacing:
MIAMI•DADE COUNTY
APPROVED
Wood, non -insulated
Min. 19/32" plywood or wood plank
Anchor sheet mechanically fastened to deck, membrane adhered
One or more plies of ASTM D 226 Type II or ASTM D 2626.
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick
TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered.
See General Limitations Below. •
•
• . •
.. . • .
Wood, non -insulated •
Min. 19/32" plywood or wood plank
•••.
••
Anchor sheet mechanically fastened to deck, membrane adhered • • • •
One or more plies of ASTM D 226 Type II or ASTM D 2626. • . • .. •
•
....
. .
••..
.. .
. . .
•s .
•
•
•
•
. .
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a imn n m 4" head lap. (for
base sheet only) •
Elastoflex S6 G, hot asphalt applied
See General Limitations Below.
• •
• . .
.• .
.••
. .
.. .
. . •
Wood, non -insulated
Min. 19/32" plywood or wood plank
Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
One or more plies of ASTM D 226 Type II or ASTM D 2626.
Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Polystick TU Plus, self -adhered.
See General Limitations Below.
•
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of 8
•
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
•
membrane from the center outward in both directions. '
5. For ridge applications, center the membrane and roll from the center outward in both2l t tibas. • • •
6. Roll or broom the entire membrane surface so as to have full contact with the surface: giving special attention '
to lap areas. • • •
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly .0 rent Pre i :Control
Notice of Acceptance. • •
•• •
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape•aliaif be •
pressed in place and formed around the protrusion to ensure a tight fit. A second layfr e# t plystick shall be • •
applied over the underlayment. '
• • •
•• •
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles, wood shakes and shingles, non-structural metal roofmg, roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofmg.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofmg and roof tile systems.
Polystick TU Max may be used in non-structural metal roofmg and roof tile systems.
Elastoflex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
• • •
•• • • •
• • •
•
Exposure Limitations (Days)
MTS
IR-Xe
Elastoflex
S6 G
TU
Plus
TU P
Tile Pro
Dual Pro
TU Max
MTS Plus
Winter Haven, FL
180
90
180
180
180
180
180
180
180
Hazelton, PA
N/A
90
N/A
180
N/A
N/A
N/A
180
N/A
All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 5 of 8
Rule 61G20-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications!
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximutpxppfslope
•
.. .
shall be as follows: (See Table Below)
Tile
Profile
Polystick
MTS
Elastoflex
S6 G
Polystick TU Plus,
TU P, Tile Pro,
Dual•••••
Pro
Polystick
TU Max
Polystick; • •
MTS PIit3 •'
1
• • •
System (E3) •
MTS Pita with :
TVPtus
Flat Tile
Prohibited
4:12
6:12
6:12
5:1i
.6:12
without battens
• 4
• • • •
•. . .
• • •
•
Profiled
Prohibited
4:12
6:12
6:12
4:12": •:
6:12
Tile
without battens
_
• •
The above slope limitations can be exceeded only by using battens in accordance with tht Approveel•'Fj a System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required', they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyg1a-ss' Tile loading detail below for loading procedure — two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for
all underlayments except Polystick MTS which shall be loaded onto battens.
0
O.
0
10
N
APPROVED;
•
•
•
•
..••
. .
.•..
•
••
•
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 6 of 8
•
11. Refer to prepared roofmg system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofmg products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results. • .
• •.
• • .
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICI{ lE6IBRAil(ES' •
•
.•
•
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECflJC.APPLICATTQ• NS. . •
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOM11188DATIONS, • • • •
.. .
W •
1. Polyglass does accept the direct application of Polystick underlayment membranes to od decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to Oilat:his is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products. •
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edgeseam as per ▪ Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 '/s" metal aiseas.
required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6 '/ "/12", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
•
•
•
MIAMI•DADE COUNTY
APPROVED
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 7 of 8
l
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563. • •
• . . .
14. Polyglass recommends that applicators follow good roofmg practices and applicable ppQ a .duj es as oatlnad by . .
the National Roofmg Contractors Association (NRCA). •
•••• •••• . .
• •
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECtiefe APPLICA`tIbNS. • .
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOIV S E ATIONB: • : •
END OF THIS ACCEPTANCE
• . .
•
• •. •
•. .
.
•. • • •
• •.
NOA No.: 17-0614.22
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 8 of 8
MIAMI-WIDE
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Entegra Roof Tile, LLC
1289 NE 9th Ave
Okeechobee, FL 34972
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.gov/economy
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). ' •
•
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Pro▪ duct • t ontrol Becton
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the MI ;g have thisproduct •
or material tested for quality assurance purposes. If this product or material fails to perform in tl •accepted mppgr, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, moth fN,.gt'suspefld 413% Qse
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptaar.e, if it is .. .
determined by Miami -Dade County Product Control Section that this product or material fails tnmeer the requiresrients
of the applicable building code. •
This product is approved as described herein, and has been designed to comply with the Florida Bty.kling Code
including the High Velocity Hurricane Zone of the Florida Building Code.
.. . .. .
. . .
.. •
DESCRIPTION: Bela "High S" Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-1120.05 and consists of pages 1 through 5.
The submitted documentation was reviewed by Gaspar J Rodriguez.
MIAMFDADE COUNTY
APPROVED
NOA No.: 16-0112.06
Expiration Date: 07/13/21
Approval Date: 02/25/16
Page 1 of 5
•
•
.
-a t
ROOFING ASSEMBLY APPROVAL
Cate2orv: Roofing
Sub-Cateeorv: Roofing Tiles
Material: Concrete
Deck Type: Wood
1. SCOPE
This approves a roofing system using Entegra Bella "High S" concrete roof tile as manufactured in Okeechobee,
FL and described in Section 2 of this Notice of Acceptance. For use in locations where the pressure requirements,
as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in
compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be
prepared as a moment based system.
2. PRODUCT DESCRIPTION
• • .
. . . .
.. . .
•
Manufactured by Test Product:.. •
Applicant Dimensions Specifications Description.. • • • • • • •
•
•••• •.••
Bella "High S"
Trim Pieces
Length = 16 '''A"
Width = 13-'/4"
Thickness =''A"
1= varies
w = varies
varying thickness
2.1 MANUFACTURING LOCATION
1. Okeechobee, FL
TAS 112
Type 2
Class II
TAS 112
High profile, interlocking, eattiptle0 conc;@te je2f tile
equipped with two nail holes' Fbt mechanldal'mortar •
or adhesive set applications. • • ' .
•Accessory trim, concrete ro¢f pits for Ilse at hips, • •
rakes, ridges and valley termlatiofis. • • • • • •• •
.• .
2.2 EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
The Center for Applied Engineering, 25-7094-(3, 6 & 9) Static Uplift Testing Oct. 1994
Inc. TAS 102
The Center for Applied Engineering, 25-7120-(1 & 2) Static Uplift Testing Nov. 1994
Inc. TAS 102
The Center for Applied Engineering, 25-7183-(3 & 4) Static Uplift Testing Feb. 1995
Inc. TAS 102
The Center for Applied Engineering, 25-7214-(3, 4, &7) Static Uplift Testing March, 1995
Inc. TAS 102
The Center for Applied Engineering, 25-7804-4 Static Uplift Testing Sep. 1996
Inc. TAS 102
Celotex Corporation
Testing Services
Celotex Corporation
Testing Services
Walker Engineering, Inc.
MIAMI-DADE COUNTY
APPROVED
520111-3 Static Uplift Testing Dec. 1998
TAS 101
520191-2-1 Static Uplift Testing March 1999
TAS 101
Calculations Aerodynamic Multiplier March 1999
NOA No.: 16-0112.06
Expiration Date: 07/13/21
Approval Date: 02/25/16
Page 2 of 5
'2.2 ' VIDENCE SUBMITTED
Test A2encv Test Identifier
Walker Engineering, Inc. Calculations
IBA Consultants, Inc. 2421-94
American Test Lab of South Florida RT1210.03-15
Test Name/Report
Restoring Moment
ASTM C 1167
TAS 112-95
Date
June 2007
June 2006
Dec 2015
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may be
required, refer to applicable building code.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Miami -Dade Product •
Control Section for review. •
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applicaaiar s Standards listed • •
section 4.1 herein. ••
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the rociesi pe unless stated • •
otherwise by the underlayment material manufacturers published literature. • • • • ▪ • • • • • •
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be •tbm• plianct•Wtth• •
applicable building code. • • • •• • • ••
4. INSTALLATION
• • •
• •
••
• •
•
• •
4.1 Entegra Sales, Inc.'s Bella "High S" concrete roof tile and its components slialf be; instaljecf jn.strict •
compliance with Roofmg Application Standard RAS 118, RAS 119 and RAS 120.
•• •
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (Ibf)
Length -I (ft)
Width-w (ft)
Bella "High S" Tile
10.5
1.375
1.08
Table 2: Aerodynamic Multipliers - A (ft3)
Tile
A (ft3)
A (ft3)
Profile
Batten Application
Direct Deck Application
Bella "High S" Tile
0.349
0.378
Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf)
Tile
Profile
2":12"
3":12"
4":12"
5":12"
6":12"
Greater than
7":12"
Bella "High
S" Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
6.19
6.89
6.11
6.80
5.99
6.67
5.85
6.51
5.68
6.33
5.50
6.13
MIAMI•DADE COUNTY
APPROVED
NOA No.: 16-0112.06
Expiration Date: 07/13/21
Approval Date: 02/25/16
Page 3 of 5
•
i• T
Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf)
for Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15/32" plywood)
Direct Deck
(min. 19/32" plywood)
Battens
Bella "High
S" Tile
2-10d Ring Shank Nails
28.6
41.2
19.4
1-10d Smooth or Screw
Shank Nail
5.1
6.8
2.8
2-10d Smooth or Screw
Shank Nails
6.9
9.2
7.3
1 #8 Screw
20.7
20.7
18.1
2 #8 Screw
43.2
43.2
29.8
1-10d Smooth or Screw
Shank Nail (Field Clip)
23.1
23.1
• . • .
• 19.9
1-10d Smooth or Screw
Shank Nail (Eave Clip)
29.3
29.3 •• •
:Z�Q.
2-10d Smooth or Screw
Shank Nails (Field Clip)
27.6
27.6
• `• • `
` • `•
3e.6
""b .
2-10d Smooth or Screw
Shank Nails (Eave Clip)
38.1
38.1
,• ••••'.'.'
,4.1.0
.
2-1Od Ring Shank Nails'
33.1
48.1 : • •:
• 50.9
1. Installation with a 4" tile headlap and fasterners are located a min. of 2'/z" from head of tile. •
•• •
•
••
•
•
• •
• .••
•
•
•
•
•• • •
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) • • •
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Bella "High S" Tile
Adhesive
29.32
1 See manufactures component approval for installation requirements.
2 Flexible Products Company TileBond Average weight per patty 10.7 grams.
3M- 2-Component Foam Roof Tile Adhesive AH-160 Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Bella "High S" Tile
3M'" 2-Component Foam Roof Tile Adhesive AH-160
66.53
3MT" 2-Component Foam Roof Tile Adhesive AH-160
38.74
3 Large patty placement of 63grams of 3M- 2-Component Foam Roof Tile Adhesive AH-160.
4 Medium patty placement of 24grams of 3M'• 2-Component Foam Roof Tile Adhesive AH-160.
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf)
for Mortar Set Systems
Tile Profile
Tile Application
Attachment Resistance
Bella "High S" Tile
Mortar Set5
24.5
5 Tile-Tite Roof Tile Mortar.
MIAMI•DADE COUNTY
APPROVED
NOA No.: 16-0112.06
Expiration Date: 07/13/21
Approval Date: 02/25/16
Page 4 of 5
i 7'' 1r
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen in detail
below, or following statement: "Miami -Dade County Product Control Approved".
L
OR
ENTEG._.
•
• .. •
•
• •
ENTEGRA SALES BELLA "HIGH S" CONCRETE TILE LABEL • •
•
(LOCATED UNDERNEATH TILE) ••••• • • • • •
•• • •
•••• ••••
• •
BUILDING PERMIT REQUIREMENTS:
•• •
•
•• •• • •• •
As required by the Building Official or the applicable Building Code in order to proprdy iluate the •
installation of this system. This Notice of Acceptance on its own cannot be used to obtain abuilditg
PROFILE DRAWING
END OF THIS ACCEPTANCE
MIAMI•DADE COUNTY
APPROVED
• •
• • •
•• •
•
•
•
•• • • •
• ••
•
•. •
NOA No.: 16-0112.06
Expiration Date: 07/13/21
Approval Date: 02/25/16
Page 5 of 5