Loading...
RF-18-1563Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Permit Issue Date: 8/18/2018 Permit NO. RF-6-18-1563 Permit Type: Roof Work Classification Tile/Flat Permit Status: APPROVED Expiration: 12115/2018 Parcel Number Applicant 533 GRAND CONCOURSE Miami Shores, FL 33138-2464 1132060171350 Block: Lot: JEROME HURTAK Owner Information Address Phone Cell JEROME HURTAK 533 GRAND CONCOURSE MIAMI SHORES FL 33138-2464 Contractor(s) Phone OBENOUR ROOFING SHEET METAL 2 305-757-2612 CeII Phone Valuation: $ 45,000.00 Total Sq Feet: 4588 Type of Work: Re Roof Additional Info: RE -ROOF INSTALL CROWN WINDSOR SLATE Classification: Residential Scanning: 3 Fees Due Bond Type - Contractors Bond CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $500.00 $27.00 $5.25 $3.50 $9.00 $350.00 $9.00 $36.00 $939.75 Pay Date Invoice # 06/07/2018 06/18/2018 Bond #: 3797 Pay Type RF-6-18-67836 Check #: 9249 Check #: 9258 Amt Paid Amt Due $ 50.00 $ 889.75 $ 889.75 $ 0.00 Available Inspections: Inspection Type: Up Lift Report Tin Cap Final Roof Tile In Progress Roof in Progress Renailing Affidavit Review Roof Cap Sheet In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFID • I ceify that all the fore construction -n. ing. F ermore, I g information is accurate and that all work will be done in compliance with all applicable laws regulating e above -named contractor to do the work stated. thorized Signature: Owner / Applicant / Contractor / Agent June 18, 2018 Date Bu 'ding Department Copy June 18, 2018 1 Miami Shores Village BUILDING PERMIT APPLICATION El BUILDING ❑ ELECTRIC Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 2011 Master Permit No. Ir. I3 Sub Permit No. ROOFING ❑ REVISION ❑ EXTENSION PLUMBING ❑ MECHANICAL El PUBLIC WORKS JOB ADDRESS: City: Miami Shores County: Folio/Parcel#: ' 2 OF/ , 36) Occupancy Type: Load: Construction Type: ❑ CHANGE OF CONTRACTOR 533 6rWld C01e0L-115-e Miami Dade ❑ CANCELLATION ❑ RENEWAL ❑ SHOP DRAWINGS Zip: Is the Building Historically Designated: Yes Flood Zone: BFE: NV FFE: OWNER: Name (Fee Simple Titleholder): o Par )cd" G dG -4-1L Address: 53.3L— City: 11' PQAVIA- � C State: Tenant/Lessee Name: Phone#: Email: zip: 3/3 CONTRACTOR: Company Name: CleLLX pc) Address:6,1ti 61522 u C,z9rat 6wp �/y� City: i YL ir.L S1i trr7/�r[ D i (� State: Name: Jane 0ouf Phone#: ?OS 7f c3 7 -4 / 1- Qualifier State Certification or Registration #: C (/ I120 (0 DESIGNER: Architect/Engineer: Zip: Phone#: 3o r7t 7/ 2 Certificate of Competency #: 07a Phone#: Address: City: State: > Value of Work for this Permit: $ 451 cSquare/LinearrFF000tage of Work: tSeY Type of Work: El Addition Alteration ❑ New ) V Repai�r/Replace ❑ Demolition Description of Work: q PM l/�S% faa Ce0WA) Os o/d. /-- Slat k A-est ote- �.c 81AL .S Specify color Submittal Fee $ Scanning Fee $ Technology Fee $ ratt ofcolor thru tile: 044(9 Zip: i'WiA/ /301- Ali•veyetCsp o s74421 Permit Fee $ • Q Radon Fee $ Structural Reviews $ CCF $ CO/CC $ DBPR $ S ' Z_ Notary $ Training/Education Fee $ Double Fee $ Bond $ ' TOTAL FEE NOW DUE $� • (Revised02/24/2014) r � `Bonding Company's Name (if applicable) Bonding Company's Address City State v Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with stimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and c structi lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the r orded notes' •e of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building rmiitif issued. In the absence of such posted notice, the inspection will not ,be.approved and a reinsp ion fee will be charged. f' Signature Signature CONTRACTOR The foregoing instrument was acknowledged before me this The f•'going instrument was acknowledged before me this day of 1 I who, 20 t♦ , by 1 / day of �C , 20 / T , by rpersonally l isp rsonal y known to AIv1G � ��tlJ, who is personally known to me or who -has -produced as me or who has produced as NOTARY PUBLIC: Sign: OWNER or AGENT who did take an oath. omofe / •.Ei1 ..............• • #091188V • Print: Seal: ' ' ;�� Q �• 'Pon STAIE **********************d'1441 AlAM • • APPROVED BY identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: (AT ERIN ► r F Notary Public - State of lor da Commission t GG 104296 My Comm. Expiics May 14, 2021 tier ;h j tnrougr National Notary Assn. ******************************************** *************************** r11�� Plans Examiner Zoning (Revised02/24/2014) Structural Review Clerk SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the desjgnated space indicates that the item has been explained. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually / conealed prior to removing the existing roof system). 4. Y /'i Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking /can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, r% roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of m� taini the appearance. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge_if rflo scuppers (wall outlets) are not provided. It may be necessary to install overflow pers in a danc1 the requirements of Sections R4402, R 03 and R4413. wner/Agent's Signature Date 33 Property Address Revised on 7/9/2009 LD;07/01/2015; ractor Signature •• •• • •. • • • aie• .••• .•.. •. . .. . Permit Number • • • • • • .••. • • • . . • • • • • . . ..• • ...• • • .... ... • • • .. • • • • •. . • . . •• • • • • RECEIVED JUN 0 7 018 Master Permit No. High -Velocity Hu ROOF ASSEMBLIES _+ ROOFTOP STRUCTURES Edition (2014) ne Uniform Permit Appl Section A (General Informatio `�) co Process t19, Contractor's Name Clow Po 7: Job Address 33 /Low Slope O Asphaltic Shingles INTERNATIONAL CODE COUNCIL ROOF CATEGORY ❑ Mechanically Fastened Tile ❑ Metal Panel/Shingles ❑ Prescriptive BUR-RAS 150 ROOF TYPE O New roof 0 Repair 0 Maintenance /Reroofing ` ROOF SYSTEM INFORMATION �) tA�- Low Slope Roof Area (SF) [ Steep Sloped Roof AREA (SSF) <�ZTotai (SF) !'� 88 2) VCc Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimen- 1 sions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 1 1 1 1 1 1 1 ... .`. - ^ c9 Mortar/Adhesive Set Tiles7,, 9� 0 Wood Shingles/Shakes N. 0 Recovering Mika iiiiiiiiiiiiiiiiliiiiiiii MINIMMEMMEMEMERMOMINWOOMMO MINIMMEMMEMMEMOMMOOMMMMEEM vf FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.37 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to license Agreement. No further reproductions authorized. ...J. . . ...'.. 1. foor 1 1 1 1 1 1 1 1 1 1 Product Approval No.: ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form. Section C (Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: 1 i. - la 3'te. I Design Wind Pressures, From RAS 128 or Calculations: 1 P1:-fit i P2:=7/. 7 P3: 0I, Max. Design Pressure, from the_spr.product I approval system: —.$-2 t 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 Deck: Type: WO ei GaugelThicllknness: 9/r Slope: `f,ft c% Anchor/Base Sheet & No. of Ply(s): r7/t Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer. Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: YzA, Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of PIy(s): PAW M 1 ve/ Base Sheet Fastener/B ndin Material: /1e; g /0 ),�� Ply Sheet(s) & No. of PIy(s):/ l '+°✓o o O Ply Sheet Fastener/Bolding MateVI: 7 17, Top Ply: �tfA4ty ,/ C7 J/i 3P Top P Fo /naa / A Fastener Spacing for�J4nchor/Base Sheet Attachment: Surfacing: Field: i0' oc @ Lap, # Rows @6 "oc Perimeter: - " oc @ Lap, # Rows st@ G " oc Comer: eC " oc @ Lap, # Rows Y@ " oc Number of Fasteners Per Insulation Board: Field Perimeter Comer Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. ew amheet FT. SGo P`'F Parapet `y Height 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 eta 7 1 • • r I' Ikv •fT.• I.'� • a ▪ • • ttia— ▪ •• • • • • • •• • • • is•••• • 1 • • 1 • • •• • • • • •. • 1• • • 15.38 INTERNATIONAL CODE COUNCIL FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) - Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: ed eklp , 1/,L z (A e /040 x aeP'.c Q - ,47 /LL Notice of Acceptance Number. /V— (Oat , c2 3 Minimum Design Wind Pressures f Agplicable (From RAS 1 7 or l alculations): 9QQ P1: P1V P1: P1: 4lr0 Deck Type: RI Slope: 12 Ridge e tilation? Y A - GA/0 Q d p/r4.t/k Type Underlayment: Insulation: TA( /3 22' t, Fire Barrier: Mean Roof Height: / 9 /0- Fastener Type & Spacing: 4WC/ Adhesive Type: TrA4 et- fjkt i sa,Co s/.) Type Cap Sheet: Roof Covering: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I 1 &ice / a1/ti4'Ja/t- Slia4t efr Type & Size Drip \ Edge: • • • • ;V4- .filer I • ' •1 • • • • • • • • • •.Ili • ••a• • • • • • • • • •• •• • • • • • • • • • • • • •• • • •• r • • • •• • 1 •� •.•• • • • •• • • • FLORIDA BUILDING CODE - BUILDING, 5th EDITION (2014) 15.39 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. INTERNATIONAL CODE COUNCIL 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 I ROOF ASSEMBLIES AND POOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mr. If the Mt values are greater than or equal to the M, values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (P1 . / x X , ie =�'.?, 3) - Mg:./7 = M„ d4 Product Approval M, (P2>.f x?.,3/3= /3/)- Mg: y.17=M,./9J`{�roductApprovalMt (P3f 7 xX,, 3/3 j4J-(j - Mg:,i:1 7 = M•7 , roduct Approval M, Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (M,) From Table Below Product Approval M 1 'Must be u I Appeals. I For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater than or I equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. 1 1 (P1: x L = x w: = ) - W: x cos 0 = F,, Product Approval F' M, required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 Method 3 "Uplift Based Tile Calculations Per RAS 127" I (P2: x L = x w: = ) - W: x cos O = F2 Product Approval F' 1 (P3:_ x L _ = x w: = ) - W: x cos G = Fr, Product Approval F' 1 1 1 1 1 1 1 1 1 1 1 1 1 1 . • •• •is... Where to Obtain Information • . .• Description Symbol y _ •• Whert n Lipg • • • •• • • • Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by ayp.otiostering analysis pre- pared by PE based on ASpg•7• • • • • Mean Roof Height H Job Site ' .40... ' ...ID - Roof Slope 0 Job Site �• • • • • • Aerodynamic Multiplier l Product Approval "' ` • • Restoring Moment due to Gravity Mg Product Approval •• • • • Attachment Resistance M, Product Approval • •'"" • •• Required Moment Resistance Mg Calculated ' • • • •• • • • Minimum Attachment Resistance F' Product Approval Required Uplift Resistance F, Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 15.40 • • • • • • • • • • • • • • • FLORIDA BUILDING CODE - BUILDING, 5th EDITION (2014) Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8. 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. • INTERNATIONAL CODE COUNCIL DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 www.miamidade.gov/economy LCFown Buildi :oducts of Florida, LLC 6018 HWY 72 Arcadia, FL 34266 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:•Windsoc Roof Tiles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision op change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an efidpfsepent oZ gpy product, • • for sales, advertising or any other purposes shall automatically terminate this NOA. Failure.tocxornply v\ith'ank• section..:. of this NOA shall be cause for termination and removal of NOA. . ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Fldif A;'and fotlbWed by tilt; • • • expiration date may be displayed in advertising literature. If any portion of the NOA is disifaye?; then rt shalibe done in its entirety. . . . . . .• INSPECTION: A copy of this entire NOA shall be provided to the user by the manufaoturer.or its disfriliutors and shall be available for inspection at the job site at the request of the Building Official. • • • This NOA consists of pages 1 through 8. The submitted documentation was reviewed by Juan E. Collao, R.A. MIAMI•DADE COUNTY APPROVED .. . . . . . ..• . NOA No.: 14-1006.037 Expiration Date:01%29/20 Approval Date: 01/29/15 Page 1 of 8 . ROOFING ASSEMBLY APPROVAL Category: Sub -Category: Material: Roofing Roofing Tiles Concrete 1. SCOPE This approves a roofing system using Windsor Roof Tiles, as manufactured by Crown Building Products of Florida, LLC as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Dimensions Test Product ' Applicant Specifications Description Windsor Shake L = 17" TAS 112 Flat, interlocking, concrete tile equipped with two W = 13" nail holes. For direct deck or battened nail -on, H = 1.2" mortar or adhesive set applications. Thickness: 0.59" Windsor Split Shake L = 17" TAS 112 Flat, interlocking, concrete tile equipped with two W = 13" nail holes. For direct deck or battened nail -on, H = 1.3" mortar or adhesive set applications. Thickness: 0.59" Windsor Slate L = 17" TAS 112 Flat, interlocking, concrete tile equipped with two W = 13" nail holes. For direct deck or battened nail -on, H = 1.3" mortar or adhesive set applications. Thickness: 0.59" Trim Pieces L = varies TAS 112 Accessory trim, concrete roof pieces for use at W = varies hips, rakes, ridges and valley terminations. Varying thickness Manufactured for each tile profile. 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name Product Description 3MT"' 2- Component Foam Roof Tile Adhesive AH-160 Two component polyurethane foam adhesive. TILE BONDT"I Roof Tile Adhesive Single component polyurethane foam roof tile adhesive. "Tile Tite" Roof Tile Mortar Premixed, pre -bagged roof tile mortar. Bonsai Roof Tile Mortar Premixed, pre -bagged roof tile mortar. "Quikrete" Roof Tile Mortar, FL-15 Premixed, pre -bagged gray roof tile mortar. MIAMI-DADE COUNTY APPROVED . • .. • . 0000 • •• . .. . ... . • . • M' iht*1,t turer •• • (With' Mr.rent NOAt . 3%i{dompany •••• The Dow.hbeulical Company Bermuda iec of Co:1nc. Bonsal American The Quikrete Companies, Inc. • • • . • . .• . NOA No.: 14-1006.03 Expiration Date: 01/29/20 Approval Date: 01/29/15 Page 2 of 8 • • • 2.2 MANUFACTURING LOCATION 1. Arcadia, FL 2.3 SUBMITTED EVIDENCE: Test Agency Redland Technologies The Center for Applied Engineering, Inc. Celotex Corporation Testing Service Walker Engineering, Inc. MIAMI•DADE COUNTY APPROVED Test Identifier 7161-03 Appendix III 7161-03 Appendix II Letter P0631-01 P0402 94-060A 94-084 25-7094-2 25-7094-8 25-7094-5 25-7183-6 25-7183-5 25-7214-1 25-7214-5 Project No. 307025 Test #MDC-77 520109-1 520111-4 520191-1 Calculations Calculations Calculations Calculations Calculations Calculations Calculations Calculations Calculations Calculations Calculations Test Name/Report PA 102 & PA 102(A) PA 108 (Nail -On) PA 108 (Nail -On) PA 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails PA 101 (Mortar Set) PA 101 (Adhesive Set) PA 102 (4" Headlap, Nails, Direct Deck, New Construction) PA 102 (4" Headlap, Nails, Battens) PA 102 (4" Headlap, Nails, Direct Deck, Recover/Reroof) PA 102 (2 Quik-Drive Screws, Direct Deck) PA 102 (2 Quik-Drive Screws, Battens) PA 102 (1 Quik-Drive Screw, Direct Deck) PA 102 (1 Quik-Drive Screw, Battens) PA 100 PA 101 PA 101 PA 101 Aerodynamic Multiplier • • Moment of Gravity • • • • 25-7094 25-7496 25-7584 25-7804b-8 25-7804-4 & 5 25-7848-6 25-7183 . . . .. .. .. Aerodynamic Multipliers. Two Patty Adhesive Set System • Date Dec. 1991 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 March, 1994 May 1994 Oct. 1994 Oct. 1994 Oct. 1994 Feb. 1995 Feb. 1995 March, 1995 March, 1995 Oct. 1994 Dec. 1998 March 1999 March 1999 Center 2007 4pggst 2007 • • FebtUaly 199I ..:. April 1996. . Dec filler 19;6 • Dee fiber 1996: • • . 13ecammer 19io••• December 1906 • • .March 1995, • • 131'41999. . Avail NOA No.: 14-1006.03 Expiration Date: 01/29/20 Approval Date: 01/29/15 Page 3 of 8 • 2.3 SUBMITTED EVIDENCE (CONTINUED): Test Agency Test Identifier Test Name/Report Date American Test Lab of South RT0908.01-14 TAS 112 09/18/14 Florida RT0923.01-14 TAS 112 09/30/14 RT0923.02-14 TAS 112 09/30/14 RT0912.01-14 Restoring Moment 09/18/14 Aerodynamic Multiplier 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Miami -Dade Product Control office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Windsor Roof Tiles and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Widtlk%(ft) Windsor Shake, Windsor Split Shake, Windsor Slate 11.7 • 1.42 • • • • • • • • • • • • 'l. uA• . • • •' • • • • • • ..•. .• Table 2: Aerodynamic Multipliers - A (ft3) • • • • • • • • • • • . -- - Tile Profile A (ft3) Batten Application ..L(tr) •.; ... Direct Deeh,Applicatien Windsor Shake, Windsor Split Shake, Windsor Slate 0.289 • • - - -. •••. c3 •.. . ;•.. •:9 • �� • • •' • MIAMI-DADE COUNTY APPROVED NOA No.: 14-1006.03 Expiration Date: 01/29/20 Approval Date: 01/29/15 Page 4 of 8 • . • .. • •• .. • Table 3: Restoring Moments due to Gravity - M9 (ft-Ibf) Tile Profile .. .. 2":12" .. .. 3 :12 4":12"5:12 .. .. .. .. 6 :12 7":12" or greater Windsor Shake, Windsor Split Shake, Windsor Slate Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 8.27 8.26 8.19 -811 )8' 07 8.04 7.91 7.87 7.72 7.67 7.50 7.46 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mechanically Attached Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Windsor Shake, Windsor Split Shake, Windsor Slate 2-10d Ring Shank Nails 30.9 38.1 17.2 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 .... 2-10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9. • `• • ` : • • • • 32.2 • • • • • • • ... 2-10d Ring Shank Nails' 50.3 65•5. • •.•. . • • ft8.3 .... • :•• .•• 1 Installation with a 4" tile headlap and fasteners are located a min. of 2%" from head of tile. • . • • •.: • • • MIAMI-DADE COUNTY APPROVED • . • • •• • • • • • • •• • •• . • • • • • • •. .. • • • • • • NOA No.: 14-1006.03 Expiration Date: 01/29/20 Approval Date: 01/29/15 Page 5 of 8 Table 5: Attachment Resistance Expressed as a Moment M f (ft-Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Windsor Shake, Windsor Split Shake, Windsor Slate Adhesive2 31.33 2 See manufacturer's component approval for installation requirements. 3 TILE BOND'"' Roof Tile Adhesive; Average weight per patty 13.9 grams. 3MTM 2-Component Foam Roof Tile Adhesive AH-160; Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mt (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Windsor Shake, Windsor Split Shake, Windsor Slate 3M'M 2-Component Foam Roof Tile Adhesive AH-160 118.94 TM 3M 2-Component Foam Roof Tile Adhesive AH-160 s [0.4] 4 Large paddy placement of 45 grams of 3M'T 2-Component Foam Roof Tile Adhesive AH-160. 5 Medium paddy placement of 24 grams of 3M'M 2-Component Foam Roof Tile Adhesive AH-160. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Windsor Shake, Windsor Split Shake, Windsor Slate Mortar Set6 39.0 6 See specific mortar manufacturer's Notice of Acceptance 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detai? 8'elow), t1r• •; • following statement: "Miami -Dade County Product Control Approved". MIAMI.DADE COUNTY APPROVED .. . •••• . . • • • • . • . • ••.. •..• • • . . • • • • ••• . . . . • •.• •. •• • . . • • • • . • •. •. • . •. . . • .. WINDSOR SHAKE, WINDSOR SPLIT SHAKE, AND WINDSOR SLATE ROOF TILES (LOCATED ON UNDERSIDE OF TILE) • • • • NOA No.: 14-1006.03 Expiration Date: 01/29/20 Approval Date: 01/29/15 Page 6 of 8 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWINGS FASTENER HOLES WINDSOR SLATE MIAMI DADE COUNTY APPROVED • • • • • • • • •••• • • J • • •• • •••• • • • • • •• • • • • • •••• •••• • • • • • • •••• •••• • • ••• • • • • • ••• •• •• • • • • • • •• • • • • • • • . • •• • •• • •• • • • • • • NOA No.: 14-1006.03 Expiration Date: 01/29/20 Approval Date: 01/29/15 Page 7 of 8 PROFILE DRAWINGS (CONTINUED) 13" 13" FASTENER HOLES LYYINDSOR SHAKE] FASTENER HOLES WINDSOR SPLIT SHAKE END OF THIS ACCEPTANCE MIAMI-DADE COUNTY APPROVED 17" • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • . ••• • • • •• • . • • • •• • • • • • • • •• • •• • • . NOA No.: 14-1006.03 Expiration Date: 01/29/20 Approval Date: 01/29/15 Page 8 of 8 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) ICP_Adhesives an Inc. 12505 NW 44' Street Coral Springs, FL. 33065 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 www.miamidade.eov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This' product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:,ICP.Adhesives Polyset® AH-160 ---�_� LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. • • TERMINATION of this NOA will occur after the expiration date or if there has been 0,re ,ision otange in the..:. materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endwise mint of any product, for • sales, advertising or any other purposes shall automatically terminate this NOA. Failure to oornply witl1 anysection'of • this NOA shall be cause for termination and removal of NOA. • • • • • • • • • ... . . . . . ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Elkin, and followed by the • • expiration date may be displayed in advertising literature. If any portion of the NOA is disglayed; then It shill be dqt . in its entirety. . . . INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its aisinbutors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. MIAMI•DADE COUNTY APPROVED NOA No.:-17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17' Page 1 of 11 . ROOFING COMPONENT APPROVAL: Category: Sub Category: Materials: Roofing Roof tile adhesive Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product ICP Adhesives Polyset®AH-160 ICP Adhesives Foam Dispenser RTF1000 ICP Adhesives ProPack® 30 & 100 Dimensions Test Product Description Specifications N/A TAS 101 Two component polyurethane foam adhesive N/A Dispensing Equipment N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-1 60 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 • . • . . .. • Resdlis'' . .••• 1.6 lbs./ft.3 18 PSI Parallel to rise ..' •.' 12 PSI Perpendicular to rise 28 PSI Parallel to rise • 0.08 Lbs./Ft2 • • . ••. • • .•.. ...• . •• ..• •... . • • • • • • • • • •. .. . .• . • • .• • • • . . •. . • 3.1 Perm / Inch ••••' +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. MIAMI•DADE COUNTY APPROVED • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-1PA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 •O'3(QZ/99 520109-2-1 • •• • •• • • ••• • LIMITATIONS: • • • • • • • • • • • • • • • • • 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assemb1jfor fire rating • 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profile. • • • • • • • • • • 3. Minimum underlayment shall be in compliance with the Roofing Application Standard:MS 420. • 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® A11-16Q roof •atitesive with their tile assemblies shall test in accordance with TAS 101. • • •• •• •. • • • • 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Buildteg tode and •• • • • Rule 61G20-3 of the Florida Administrative Code. MIAMI DADE COUNTY APPROVED NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 • INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofmg Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP Adhesives ProPack® 30 & 100 dispensing equipment only. 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset® A11-160 has been dispensed. 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. MIAMIDADE COUNTY APPROVED • • • .... • • • ... .... .. • . • • • • .... .... • • . . • ....• .... ... • . . • • ..• ..• .. • • • • • • . • • . ... .. . . • . • • • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Area Minimum Paddy Gram Weight Eave Course - Flat, Low, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at head of tile 9-11 sq. inches at overlap 12 grams per paddy Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal edge) 20-25 sq. inches each bead 17 grams per bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: . • . AP OYED •••• • • As required by the Building Official or applicable building code in order to properly evaluate the.ftistallatidii bf this system. •' • • ••• • MIAMI DADE COUNTY APPROVED .••• • • • •• • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • • • •• • • • • • • • • •• • • • •• • • • • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 MIAM .DADE COUNTY APPROVED ADHESIVE PLACEMENT DETAIL # 1 Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. • • ••• • • •• • • High Profile / Single Pan Tile. • • • ' • • • • • • • • • • 1. Starting at the eave courr,•arppily a nit►trnt1pi 2" • • (50.8 mm) x 10" (254 mnt)V •1" (25.4 Ui1h) foam • • paddy onto the underlayiiieht '' sitioned as shown under the pan portion of tie Tile closest tq the • overlock of the tile being set! • •• • • • • 2. Continue in same manner,lnsuie apprextely 1'Z (109.7 cm2) — 23 (148.4 cm2) square intfi adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 MIAMI.DADE COUNTY APPROVED ADHESIVE PLACEMENT DETAIL"# cFlat/I:ow Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2) - 12 (77.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 nun) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. • • • • • • •••• 2. At the second course, apply Vmii?imum.2" glQ.8mm) • • x 7" (177.8 mm) x 1" (25.44411.%am paddy onto the • underlayment positioned as on underjj an portion of the tile closest tv�e wgserlock pf tte tile • • being set. .•• • • • • • ..• .. •• • 3. Continue in same manner. pie gpproximately 12" • • (77.4 cm2) - 14 (90.3 cm2) Square inch dye contact with the underside of tl 'tile. •• • •• • • . • •• • (Instructions continued on next page) • • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7of11 MIAMI•DADE COUNTY APPROVED ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm2) - 19 (122.6 cm2) square inch adhesive contact with the underside of the tile. .... • • • • •••• • • .. • •••• • • • ..• • • • • • •••• •••• • • • •••• •••• ••• • • • .. .. .. • .. • • • • • f • • • .. • .. • • .. • • • • • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 Flat/tow Profile Tile Medium Profile The MIAMI-DADE COUNTY APPROVED 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in2 (109.7-148.4 cm2) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 in2 (51.6-58.1 cm2) of adhesive contact with the underside of the tile. (Instructions continued on next page) .... . . • .... • . . .. . .... . . .... . . .. . • .... . . . .. • .... .... ... . • . .. .• . . • . • • . . • . . .. • .. . • • • NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) High Proffitt MIAMI DADE COUNTY APPROVED 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9 (58.1 cm2) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. • • • • .... .. . .... • • • .. . • • .... .... • • • • .... .... ... . . . • . .. .. .. • . . • • • • • • • .. • . . • .. . • . • .• . . . • .• . . NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 . ADHESIVE PLACEMENT DETAIL Two PIECE BARREL 1) Place enough adhesive to achieve 65 to 70 sq. in. in contact with the pan tile. 2) Turn covers upside down. Place adhesive in to 1 in. from outside edge of cover tile. Then install the tile. Ensure 20 to 25 sq. in. contact area. Underlayment Eave dosure (motar shown) Weephole Fascia Board Steep pitch applications (when required) Sheathing Remove top portion of the eave course cover tile. Abut to second course of pan tiles. Ensure save end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile MIAMI•DADE COUNTY APPROVED Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm2) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles ate • considered optional. • '• . . . .. . 1••• • 5. When additional nailingis require•d, ea' (50.8 mm) x 4" (101.6 mm) tititlers•or the tiewire system using galvanize t,Wiuless steel; br copper wire and compatilire nails may lie psed. • • . • END OF THIS ACCEPTANCE . . ..• .. • . • • • •• • •. .• • • • • • .• . • •. • • • . • . NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 • DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) CertainTeed Corporation 18 Moores Road Malvern, PA 19355 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.eov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:(CertainTeed-Underlayment-Systems LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. ••••• • TERMINATION of this NOA will occur after the expiration date or if there has been a revision or chan.mirke materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endot ertiefit of annro$uct, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure fifi t>S�d 1y with anX section of this NOA shall be cause for termination and removal of NOA. • • • •••• •••• •' • • ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Flgveli,find foll:Ai by th,.... expiration date may be displayed in advertising literature. If any portion of the NOA is dispjAyel, then it shall be done • • in its entirety. • • • INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer of ts:distril1tttt end shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 14-0724.16 and consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigera. MIAMI DADE COUNTY APPROVED "we' NOA No.: 14-1028.023 Expiration Date:_11/24/19� Approval Date: 06/04/15 Page 1 of 9 ROOFING COMPONENT APPROVAL Category: Sub -Category: Material: Roofing Underlayment SBS SCOPE: This approves CertainTeed Underlayment Systems, as described in this Notice of Acceptance; designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product WinterGuard HT Manufuring Location #1 WinterGuard Granular Manufuring Location #2 WinterGuard Sand Manufuring Location #2 Diamond Deck' Manufuring Location #3& 4 MetaLaymentTM Manufuring Location #1 Black Diamond' Base Sheet Manufuring Location #2 MIAMI.DADE COUNTY APPROVED Dimensions 36" x 65' rolls 36" x 65' rolls 36"x65' rolls Test Product Specification Description ASTM D 1970 Modified fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. ASTM D 1970 Granular surfaced modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. ASTM D 1970 Embedded sand surfaced modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. 48" x 250' ASTM D 226 rolls Type II 393/8"x61' rolls 39 3/8" x 68' 7" rolls Synthetic, scrim reinforced underlayment for use under shake, shingles, slate or metal Nang. • • • • •••• • • ASTM D 1970 A film surfaced, self-adherrng underlayment for• use under metal roofing.• • • • . . ASTM D 1970 • • • • •• • .•.. .••. ••.. ..• . . • . • • • • . Granular surfaced modifies! 'fiberglass reinforced, ••....• bituminous sheet material ibr ise as an . underlayment in sloped.roofassemblies. Designed as an ice & Ngt•foruse as• an Anchor Sheet. Direct adhesion tb•w6od deck not permitted in the HVHZ. •• • . NOA No.: 14-1028.02 Expiration Date: 11/24/19 Approval Date: 06/04/15 Page 2 of 9 • • TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Flintlastic GTA Manufuring Location #1 All Weather/Empire Base Sheet Manufuring Location #1 Dimensions 39 3/8" X 32' 10" rolls 39 3/8" x 65' 10" rolls DryRoof''TU 39 3/8" x 61' Manufuring rolls Location #1 CFlint antic GMS Manufuring Location #1 Flintlastic SA Cap Manufacturing Location #1 Roofers' Select Manufacturing Location #5 39-3/8" x 32' 10" rolls 393/8"x33'11" rolls 36" x 144' rolls MANUFACTURING LOCATION: 1. Little Rock, AR. 2. Shakopee, MN 3. Hangzhou, China 4. Silvassa, India 5. Shreveport, LA MIAMI DADE COUNTY APPROVED Test Specification ASTM D 6222 Grade G Type I ASTM D 4601 Type lI TAS 103 Product Description Granule surfaced APP Modified Bitumen membrane with non -woven polyester mat reinforcement for torch application. Asphalt coated fiberglass reinforced base sheet. A polyester fabric surfaced, self -adhering underlayment. ASTM D 6164 Granule surfaced SBS Modified Bitumen Grade G membrane with non -woven polyester mat Type I reinforcement for mop application. TAS 103 Polyester reinforced, self -adhering SBS modified bitumen cap sheet. ASTM D226 An asphalt -impregnated, organic felt reinforced Type I with glass fibers, roofing underlayment. • • • • •• • • • • • • • • • • • • • •• •• • • • • • a • • s • •a • •••• • • • • • • •b•• { ♦ • •• • • • • • • •••• • • • • • • • • • • • • • • •• • • • • •• • • • • • • • • • • • • NOA No.: 14-1028.02 Expiration Date: 11/24/19 Approval Date: 06/04/15 Page 3 of 9 • EVIDENCE SUBMITTED: Test Agency Momentum Technologies, Inc. TrinitylERD PRI Construction Materials Technologies, LLC InterTek Testing Services Ltd. MIAMI•DADE COUNTY APPROVED Test Identifier AX31G8D AX31 G8G 3530.12.05-1-RI 3523.03.05-R2 C32240.03.10 C3500.04.10 C31860.05.10 C30280.12.09-R2 C31410.10.10-R1 C30890.03.10-1 C40050.09.12-2 C34940.09.11-R1 C32930.01.11-R2 C45240.01.14-1 C45240.01.14-2 CTC-075-02-01 CTC-075-02-01 CTC-093-02-01 CTC-189-02-01 CTC-163-02-01 10103165000Q-002C 101227796C0Q-003C 10103165000Q-005C Test Name/Report ASTM D4601 ASTM D6222 ASTM D1623 ASTM D1623 ASTM D4977 TAS 103 ASTM D1623 ASTM D226 ASTM D5147. ASTM D4798 ASTM D1970 ASTM D1970 TAS 103, ASTM D1623 ASTM D1623 ASTM D1970, TAS 110 TAS 103, TAS 110 ASTM D1623 TAS 103 ASTM D6164, ASTM D4798 ASTM D1623 ASTM D6757, ASTM D226, ASTM D4869 ASTM D226 ASTM D4798 ASTM D4869 • . • •• • • .... • • .... . . • • • • • • . • • • ..• Date 09/05/08 06/05/09 10/05/09 01/12/10 03/04/10 04/01/10 05/18/10 12/11/09 11/02/12 03/17/10 09/28/12 10/04/11 01/20/14 01/15/14 01/24/14 10/07/11 10/07/11 08/09/11 11/18/13 05/09/13 08/13/13 08/13/13 ....08/13/13 • • •••• ... . • . . •• • • • • • • •••• • • •••• ••• • .. •• • • • • •• • • • • • • • • • • • • • NOA No.: 14-1028.02 Expiration Date: 11/24/19 Approval Date: 06/04/15 Page 4 of 9 • APPROVED ASSEMBLIES: Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened to deck. Anchor Sheet: (4:12 or Above) One or more plies of Diamond Deck with a minimum 4" headlap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Surfacing: (2:12 to < 4:12) One or more plies of Diamond Deck with a minimum 20" headlap and a 12" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Vertical joints should be offset 36" minimum. Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof applications. Must Comply with applicable Roofing Application Standards and Building Codes Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(2): Anchor sheet mechanically fastened to deck. Anchor Sheet: (4:12 or Above) Two plies of Roofers' Select with a minimum 2" headlap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. (2:12 to < 4:12) Two plies of Roofers' Select with a minimum 19" headlap and a 12" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Vertical joint should be offset•72" •.• •• ••.•. minimum. • , • ••• • Surfacing: Shall be acceptable for use in approved asphaltic shingle applications,pat,Comply with applicable Roofing Application Standards and Building Codes •• . • .•••••• • • •••• •••• MIAMI.DADE COUNTY APPROVED • • •• •• • . • • • • • • . • .. • • • • • •• . • .•• • • � • .• . • • • • • NOA No.: 14-1028.02 Expiration Date: 11/24/19 Approval Date: 06/04/15 Page 5 of 9 Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(3): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Membrane: Surfacing: MIAMI•DADE COUNTY APPROVED One or more plies of Flintlastic GTA torch applied to anchor sheet or WinterGuard HT, WinterGuard Granular, WinterGuard Sand, MetaLayment, DryRoof TU or Black Diamond Base Sheet self -adhering membrane adhered to the anchor sheet with a minimum 3" headlap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the membrane is acceptable. If membrane is strapped, then anchor sheet must also be strapped. Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof applications. Must Comply with applicable Roofing Application Standards and Building Codes ...• • • . • . .... • . ) .... • • .. . • • .... ••• . ........ ... • .. .. . • • • . . •• • . • • • ... . . . .. . . . . • • • . . • • • • • • • • • NOA No.: 14-1028.02 Expiration Date: 11/24/19 Approval Date: 06/04/15 Page 6 of 9 Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(4): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor Sheet: One ply of ASTM D 226 Type II organic felt or All Weather/Empire Base mechanically attached with a minimum 4" side lap and a minimum 6"end lap. Anchor sheet shall be applied at a right angle (909) to the slope of the deck with approved annular ring shank nails and tin caps at a fastener spacing of 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll of the base sheet. Ply Sheet: (Optional) One or more plies of an ASTM D226 ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: cOneply of Flintlastic GMS adhered in a full. mopping_of.Type IV asphalt applied_ within the EVT range and at a rate of 20-40 Ibs./sq or Flintlastic GTA torch applied to the preceding sheet or DryRoof TU, Flintlastic SA Cap, self -adhering membranes adhered to the preceding sheet with a minimum 4" side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the membrane is acceptable. If membrane is strapped, then anchor sheet and ply sheet must also be strapped. Surfacing: LABELING: When used in Tile roof systems the cap sheet shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum of 12" o.c. at the side laps and 6" o.c. at the end laps. No nails or tin caps shall be exposed. •Flintlastic SA Cap, Flintlastic GTA, Flintlastic GMS and DryRoof TU may be used with any approved roof tile system mechanically fastened as specified in their current NOA. •Flintlastic SA Cap, Flintlastic GTA, Flintlastic GMS and DryRoof TU maybe used with any approved roof.tile,system adhered -as -specified in -their current NOA using any foam adhesive listed and having a current tile adhesive NOA approval:— • •••• • • Must comply with appropriate Roofing Application Standard RAS 1 +8,,RAjS • 119, CMS 120 and applicable Building Codes. ' • • •'• • • • • • • • • • • • • • • • • • • All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer'rrpa ne orlogp, City, state and the following statement: "Miami -Dade County Product Control Approved" or the Mtan'iltDade County Product Control Seal as shown below. • • • • • • MIAMI-DADE COUNTY APPROVED MIAMI-DADE COUNTY APPROVED • • • • • •• • • •• • • • • • • • • •• • • NOA No.: 14-1028.02 Expiration Date: 11/24/19 Approval Date: 06/04/15 Page 7 of 9 BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. CertainTeed underlayment roofing systems utilizing Flintlastic GTA, WinterGuard HT, WinterGuard Granular, WinterGuard Sand, Diamond Deck, MetaLayment, DryRoof TU or Black Diamond Base Sheet as a cap membrane shall be acceptable for use in asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof applications. CertainTeed underlayment roofing systems utilizing Roofers' Select shall be acceptable for use in asphaltic shingles. 3. CertainTeed underlayment roofing systems utilizing DryRoof TU, Flintlastic SA Cap, Flintlastic GTA or Flintlastic GMS as a cap membrane shall be acceptable for use in foam adhesive set and mechanically fastened roof tile systems as specified in the surfacing option of the approved assemblies. 4. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. CertainTeed underlayment roofing systems shall be installed in strict compliance with applicable Building Code. 5. CertainTeed underlayment roofmg systems membranes shall be applied to a smooth, clean and dry surface with deck free of irregularities. 6. CertainTeed underlayment roofing systems membranes shall not be applied over an existing roof membrane as a recover system but may be applied over an approved roofing Base/Anchor sheet underlayment. 7. WinterGuard HT, WinterGuard Granular, WinterGuard Sand, Black Diamond Base Sheet, Flintlastic SA Cap, MetaLayment, Diamond Deck, Flintlastic GMS, and Flintlastic GTA shall not be left exposed as a temporary roof for longer than 180 days of application. DryRoof TU and Roofers' Select shall not be left exposed as a temporary roof for longer than 30 days after application. 8. CertainTeed underlayment products may be used with any approved roof covering Notice of Acceptance listing CertainTeed underlayment products as a component part of an assembly in the Notice of Meerance. If CertainTeed underlayment products are not listed, a request may be made to the Aulhoi i?y Having Jurisdiction • • (AHJ) or Miami -Dade County Product Control for approval provided that appropriate documentati+gq is provided..:. to detail compatibility of the products, wind uplift resistance, and fire testing results. • 9. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking well. Swebp • the deck thoroughly to remove any dust and debris prior to application. • • • • • • • •• • 10. When applying the membrane in the valley, start at the low point and work to the high ggini,ralling the'iimbrane.... from the center outward in both directions. • • 11. Roll or broom the entire membrane surface so as to have 100% contact with the surfaced giving spectal.itUntion to overlap areas. . •• •. 12. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Pi'ttdlfct'Control Notice of Acceptance and applicable Building Code. 13. The maximum roof slope for use as roof tile underlayment for direct -to -deck tile assemblies shall be as follows: (Limitations noted below are a result of the tile stacking/tile loading performance and do not reflect to that of the underlayment. See Table Below) MIAMI-DADE COUNTY APPROVED NOA No.: 14-1028.02 Expiration Date: 11/24/19 Approval Date: 06/04/15 Page 8 of 9 LIMITATIONS: Tile Profile Flintlastic GMS1 Flintlastic SA Cap' DryRoof' TU3 Flintlastic GTA3 Flat Tile 4:12 6:12 6:12 6:12 Profiled Tile 4:12 5:12 6:12 6:12 1The following is applicable to all systems using and Flintlastic GMS •Slopes up to 4:12 — Stage by placing two tiles perpendicular to the slope followed by maximum four tiles on top parallel to the slope for a total of 6 tiles. (Illustrated in Figure 1 below). •Slopes greater than 4:12 — Horizontal batten strips are required. Stage tiles touching horizontal battens; a maximum of 10 tiles shall be stacked parallel to the slope (See Figure 2 below). 'The following is applicable to all systems using Flintlastic SA Cap: •Slopes up to 5:12, Profiled Tile — Stage by placing two tiles perpendicular to the slope followed by maximum four tiles on top parallel to the slope for a total of 6 tiles. (Illustrated in Figure 1 below). •Slopes greater than those shown in the above table — Horizontal batten strips are required. Stage tiles touching horizontal battens; a maximum of 10 tiles shall be stacked parallel to the slope (See Figure 2 below). 3The following is applicable to all systems using DryRoor TU and Flintlastic GTA: •Tiles shall be stored on battens on roof pitches greater than 6:12". Front View Figure 1: Staged Method, MIAMI-DADE COUNTY APPROVED Front View Figure 2: Batten Method • • . • . • • • .` f • Y ♦ } •• • ••. ide Vieyti..•• FigPure.2 Batten Method • • .• .1 END OF THIS ACCEPTANCE • • • • • •• • ••• • • • .. • .• . . . • .• • • •• • • . • NOA No.: 14-1028.02 Expiration Date: 11/24/19 Approval Date: 06/04/15 Page 9 of 9 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) CGAF- J 1 Campus Drive Parsippany, NJ 07054 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 www.miamidade.eov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built:Up Roof Systems for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product.. • • • • • •• •••• TERMINATION of this NOA will occur after the expiration date or if there has been D.xp ' on or caliahge in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as•an esidorsement,of any product, for sales, advertising or any other purposes shall automatically terminate this NOtar.4F.ailureJ•Cdrgply with any section of this NOA shall be cause for termination and removal of NOA. • • • • • • • • ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Nr5AaTrdispla%edd then • it shall be done in its entirety. • • • INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer br its disfrr$ntors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 13-1022.15 and consists of pages 1 through 31. The submitted documentation was reviewed by Jorge L. Acebo. MIAMI•DADE COUNTY APPROVED NOAdNo.: 14-1030.01 2 Expiration Date: 11/04/18 Approval Date: - 05/04/11 Page 1 of 31 • • • • Membrane Type: BUR Deck Type 1I: Wood, Non Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(4): Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply. Fire Barrier: TOPCOAT FireOutT" Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet (optional) VersaShield® Solo' Fire -Resistant Slip Sheet, installed per manufacturer's installation instructions. Anchor sheet: £GAFGLLASS_ #75. Base Sheet, Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or GAFGLAS® Stratavent® Venting Nailable Base Sheet is secured as described below. Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. diameter Option #1: tin caps are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —45 psf. See General Limitation #7) Fastening Miami:DadE County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. di-a_eter Option #2: tin'caps are spaced 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in. o.c. iri the field of the sheet in.two staggered rows (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill -Tee' #14 Fasteners and Drill-TecT" 3 in. Standard Steel Plates, Drill-TecT" AccuTrac® Option #3: Flat Plates or Drill-TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-TecTM #14 Fasteners and Drill -Teem 3 in. Standard Steel Plates, Drill -Tee' AccuTrac® Option #4: Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Limitation #7) Fastening Drill-Tec' #14 Fasteners and Drill -Tee' 3 in. Standard Steel Plates, Drill-TecT' AcGuTfac® Option #5: Flat Plates or Drill-Tec' 3 in. Ribbed Galvalume Plate (Flat) are spaegci 8 ip. o.c. itt.the min. 4 • • in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet it►.tbrea staggered rews. •(Maximum Design Pressure: —97.5 psf. See General Limitation #7) nstalled per manufacturer's installation instructions.) • Base Sheet: Ruberoid® 20 Smooth adhered in a full mopping of hot asphalt applie8.at 2t1-40'113.asq • . • • — ••. Cap Sheet: �GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap, Slieetor GAFGLAS .. EnergyCap' Mineral Surfaced Cap Sheet adhered in —a full mopping of hod asphalt�,ppj l at 20 — t 40lbs./sq. installed per inanufactiiWr's installation instructions. — : . • . • • .. • • MIAMI•DADE COUNTY APPROVED NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 29 of 31 Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 1bs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Aluminum Fiber Roof Coating. 1. Maximum Design Pressure: See Fastening Above. , MIAMI-DADE COUNTY APPROVED . . . .. • •••• . • • • • • . . .• . • • .. • • • • • .. •. • • .... • • •••• •... . . • .. . . •••• • • ..•• • • . .. . . .. • . • • NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 30 of 31 . • . • WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® Flex Ply' 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum Yo" DensDeck' Roof Board or %" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofmg Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. • • • • •• 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements pf tljes, areas.' Tastener • • densities shall be increased for both insulation and base sheet as calculated in complianceWithltoofix Ap$licatiQQ••;. Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional EngineQr, • • Registered Architect, or Registered Roof Consultant (When this limitation is specific4yreferredwithin • • this NOA, General Limitation #9 will not be applicable.) ' ....'•• • • • . • 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination delta shalreo»fotm to .• Roofing Application Standard RAS 111 and applicable wind load requirements. • • • • 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure !onus field, • . perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted foj enlinced 1$§fening at • enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitatibnis spefifgaliy • referred within this NOA, General Limitation #7 will not be applicable.) • • • 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE MIAMI-DADE COUNTY APPROVED NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 31 of 31 • .• • . 9/14/2017 ONLINE CERTIFICATIONS DIRECTORY TGFU.R1306 - Roofing Systems Page Bottom TGFU.R1306 Roofing Systems Roofing Systems See General Information for Roofing Systems GAF_ 1 CAMPUS DR PARSIPPANY, NJ 07054 USA R1306 "RUBEROID® 20 Smooth" or "RUBEROID® Mop Smooth" or "RUBEROID® Mop Smooth 1.5" may be utilized as an alternate to Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 UltimaTM Base Sheet" base sheets in any of the following Classifications. 1/2-in. thick (minimum) gypsum board or 1/4-in. thick (minimum) Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuard'"' Roofboard" or 1/4-in. thick (minimum) United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX) may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32-in. thick minimum) roof decks. However, the butt joints in the gypsum board and Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardTM Roofboard" are to offset a minimum of 6-in. with the butt joints in the roof deck. If polystyrene is part of the roof system, it must be placed below the overlayment board. 1/4-in. thick (minimum) "SECUROCK® Roof Board" (Type FRX-G) and "SECUROCK® Glass -Mat Roof Board" (Type SGMRX) are limited to a maximum 3:12 slope when used over a combustible deck in a system with any UL Classified insulation except polystyrene. Multiple plies of Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex PIy 6" or "Tri-Ply® Ultra -Flexible Ply 6" may be adhered to Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuard '" Roofboard" in hot roofing asphalt. "GAFGLAS® FIexPIy"" 6 5L" and "GAFGLAS® FlexPiy"" 6" may be used interchangeably in any roof covering system listed below. "EnergyGuardTM Ultra" is an acceptable altemate to "EnergyGuardTM" in any applicable Classification. "GAFGLAS® Stratavent® Nailable Venting Base Sheet" may be mechanically fastened or fully adhered with hot roofing asphalt over noncombustible decks and as a recover over existing roof systems. "EnergyGuardm' Perlite Insulation" may be utilized as a cover board over "EnergyGuard""" in any of the following systems. Unless otherwise indicated, the roof insulation is mechanically fastened, fully adhered with hot roofing asphalt or UL Classified urethane insulation adhesive. Polystyrene referenced in any of the following Classifications indude insulation. •••• Unless otherwise indicated, all insulations may be adhered with any UL Classified Insulation Adhesive per thehm�afryfacturer's installation Instructions (excluding "LRF Adhesive 0") in any applicable Non -Combustible Roof Deck Classifications. •• • • •••• • • • •• • "EnergyGuard"" Tapered" is an acceptable altemate to "EnergyGuard"'" in any applicable Classification. "EnergyGuard"' Ultra Tapered" is an acceptable alternate to "EnergyGuard"" Ultra" in any applicable Classifiea ier.. "EnergyGuardTM NH Tapered" is an acceptable altemate to "EnergyGuard"' NH" in any applicable Classification!. • • •••• • •••• • • • • • "EnergyGuard"'NH Ultra Tapered" is an acceptable altemate to "EnergyGuard"'NH Ultra" in any applicableaassification. • • • "EnergyGuard"' Barrier Tapered" is an acceptable alternate to "EnergyGuard"" Barrier". "EnergyGuard"' NH Barrier Tapered" is an acceptable alternate to "EnergyGuard"" NH Barrier". • • . • • • • • • •• �• ••. • Minimum 1-in. thick "EnergyGuard"" Barrier' is an acceptable altemate to "EnergyGuard"" Ultra" in any applicable Ciassific>!> grf.• • Minimum 1-in. thick "EnergyGuard'" NH Barrier" is an acceptable altemate to "EnergyGuard"" NH Ultra" in any applicable Classification. ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT •• • •••••. • • • • • • •• • Type G2 asphalt glass mat base sheet ("GAFGLAS® #75 Base Sheet" or "Tri-PIy® #75 Base Sheet" or "GAFGLAS® #80 Ultima"' Base Sheet") is a suitable altemate for Type G1 asphalt glass fiber ply sheet ("GAFGLAS® Ply 4" or "Tri-PIy® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible PIy 6") in the Class A, 8 or C roof systems indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet". Perforated base sheets to be loose laid or fully adhered with hot roofing asphalt and nailable base sheets are to be mechanically fastened granule side down. As an option Type G2 asphalt glass mat base sheet ("GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 Ultima"' Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet") may be substituted for Type G1 asphalt glass fiber ply sheet httpJ/database.ul.corn/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=TGFU.R1306&ccnahorttitle=Roofing+Systems&objid=1074351... 1/48 9/14/2017 TGFU.R1306 - Roofing Systems ("GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6") as the nailed base ply in the following systems Bottom ply or base sheet may be fully adhered with hot roofing asphalt or mechanically fastened. Unless otherwise indicated, all insulations may be fully adhered with hot roofing asphalt or mechanically fastened. "GAFGLAS® Flashing" or "RUBEROID®" may be used for flashing in any of the Class A, B or C systems listed below. When "perlite" is referenced, this includes any UL Classified perlite insulation. Crushed stones or slag are suitable alternates for gravel in any of the Class A, B or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C- 15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely affect the rating. The use of 1/2-in. minimum thick gypsum board is an acceptable alternate for minimum insulation over C-15/32 thick roof decks. The use of polystyrene insulation board between minimum 3/4-in. thick perlite board and deck with rosin paper (perlite/rosin paper/polystyrene/perlite) is a suitable altemate for polyisocyanurate board in the following Class A, B or C systems. Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". "GAFGLAS® #80 Ultima"" Base Sheet" may be used in any of the following systems. "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications. Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "United Coatings"' FireShield MB Roof Coating" applied at a rate of 2-1/2 to 3-gal/100-ft2. Class A, B and C Hot roofing asphalt, for use with glass felts or modified bitumen membranes. "RUBEROID® Heat Weld" SBS roofing membranes may be used in lieu of "RUBEROID® Mop" SBS roofing membranes in any applicable Classification. 1. Deck: C-15/32 f Class A Incline: 3 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuard"' Roofboard" or minimum 1/4-In. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Vapor Barrier: — one or more plies "GAF® SA Vapor Retarder" self -adhered Insulation: — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Ply Sheet: — Three or more plies Type G1 "GAFGLAS® Ply 4" or 'Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6", fully adhered with hoot roofing asphalt. Surfacing: — Gravel. 2. Deck: C-15/32 Incline: 2 •••• Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLB "DensDeck® Roofboard" or • "DensDeck® Prime Roofboard" or "DensDeck® DuraGuard"' Roofboard" or minimum 1/4-in. thick UAitef St•ttes G yp6um• • moo. Insulation: — One or more layers perlite or wood fiber orglass fiber or polyisocyanurate • •' • Y P p y ocyanurate or urethane or pe ite/polyisoiyanurate. • composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any tfiitltAddt. • Ply Sheet: — Three or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Diy&' or'Tri;PIf ®'Lytra-Flexible PIy 6", fully adhered with hot roofing asphalt. • • • • •' • • • • • • Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap She Ott pi / AFGLAS® EnargyCap' • • • Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. • • • • • •• •• • • 3. Deck: NC Incline: 2 • • • • • • • • • • • • • • Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLG"DensDeck® Roofboard" or* "DensDeck® Prime Roofboard" or "DensDeck® DuraGuard"' Roofboard" or minimum 1/4-in. thick Unitqc1,States Gypsum Cit. • "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). • ••• •• • Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, 2-in. maximum. Ply Sheet: — Two pr more plies Type G1 "GAFGLAS® Ply 4" or'Tri-Ply® PIy 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6°, fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-PIy® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCap" Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 4. Deck: C-15/32 Incline: 1 Slip Sheet (Optional): — Red rosin paper,, nailed to deck. Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive. Base Sheet; — One ply Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-PIy® #75 Base Sheet" or "GAFGLAS® #80 Ultima"' Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet°, mechanically fastened. • • http-/database.uicom/cgi-bin/XW/template/LISEXT/1 FRAME/showpage.html?name=TGFU.R13068 ccnshortttle=Roofing+Systems&objid=1074351... 2/48 9/14/2017 TGFU.R1306 - Roofing Systems C20. Deck: C-15/32 Incline: 1 •• base Sheet: — One ply Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" mechanically fastened. Insulation (Optional): — Any thickness or combination: perlite or wood fiber or glass fiber or polyisocyanurate, mechanically fastened or hot mopped or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive: Base Sheet: — One or more plies "RUBEROID® 20 Smooth", "Ruberoid® 20 Plus Smooth" or "RUBEROID® HW 25 Smooth", mechanically fastened or fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or'Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapTm Mineral -Surfaced Cap Sheet". 21. Deck: NC Incline: 2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuard'M Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Base Sheet: — Two plies Type Gi "GAFGLAS® PIy 4" or 'Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or one ply Type G2 "GAFGLAS® #75 Base Sheet" or'Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 UltimaT" Base Sheet" mechanically fastened or fully adhered with hot roofing asphalt or one ply Type G2 "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" loose laid, mechanically fastened or fully adhered. Ply Sheet: — One or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex PIy 6", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCar' Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. Class B 1. Deck: C-15/32 Incline: 3-1/2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardT" Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Base Sheet: — Two or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® PIy 4" or "GAFGLAS® Flex Ply 6" or 'Tri-Ply® Ultra -Flexible PIy 6", mechanically fastened or fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or 'Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapTM Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 2. Deck: C-15/32 Indine: 3-1/2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardT" Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Base Sheet: — Two or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Ply Flex 6" or "Tri-Ply® Ultra -Flexible Ply 6" or Type G2 "GAFGLAS® #75 Base Sheet"or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 UltimaT" Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" or Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet", mechanically fastened or fully adhered with hot roofing Ordtt. Membrane: — One or more plies "RUBEROID® Torch Smooth" or "Tri-PIy® APP Smooth" or 'Tri-Plyt APP,Granulen a. aRUBEROIbffi •; • Torch. Granule" or +.'RUBEROID® Torch 180", torch applied or "RUBEROID® Mop Smooth" or "RUBERO(Dr MDp SmooLl l 4.5" or • "RUBEROID® Mop Plus Smooth" or "RUBEROID® Mop Granule" or "Intec Flex PRP' or "Tri-Ply® SBS Granule' fully eirleheQ with hp& • •: • roofing asphalt. •••••• • Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or'Tri-PIy® BUR Granule Cap Sheet+►ei.'c AFGLAS® EnergyCapP. • • •' Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. ,,,, • • • • • • • ' •••• •••• • • 3. Deck: C-15/32 Incline: 2-1/2 ••• , • • Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC''behsiDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardT" Roofboard" or minimum 1/4-in. thick Uni tli s Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). • • • • Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate gr ureehane or• perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composit�eol'phenolirw,any thickness. Ply Sheet: — Two or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6". or''Tri-PlneV-Flexible PIy 6", fully adhered with hot roofing asphalt.. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or'Tri-PIy® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCapr' Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. • •• • • 4. Deck: C-15/32 Incline: 2-1/2 Barrier Board (Optional): — One or more layers minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuardT" Roofboard" or minimum 1/4-in. thick United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX). Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Base Sheet: — Two or more plies Type Gi "GAFGLAS® Ply 4" or'Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or'Tri-Ply® Ultra -Flexible Ply 6' or Type G2 "GAFGLAS® #75 Base Sheet" or'Tri-PIy® #75 Base Sheet" or "GAFGLAS® #80 Ultima' Base Sheet" or "GAFGLAS® Stratavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" or Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt. http-/database.ui.comlcgi-bin/XYV/template/LISEXT/1 FRAMElshowpage.html?name=TGFU.R1306&ccnshorttitle=Roofing+Systems&objid=1074351... 6/48 4;3EOTECHNICAL 1 ENVIRONMENTAL I MATERIALS TESTING 1 ASBESTOS I ROOF TESTING I INSPECTION SERVICES I DRILLING SERVICES *' MIAMI, October 29, 2018 �oEc DYNATECH ENGINEERING CORP. WWW.DYNATECHENGINEERING.COM CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH 2017, 6TH EDITION FLORIDA BUILDING CODE TEST POTOCOL TAS-106 8 � 3 PERMIT No. PT' uiAZa%2i CLIENT: Jim Obenour: OBENOUR ROOFING: 9822 NE 2nd Avenue, #9, Miami Shores, FL 33138 PROPERTY ADDRESS: 533 GRAND CONCOURSE MIAMI SHORES, FL 33138. TILE TYPE/ATTACHMENT: Flat Roof Tile Polyfoam Set. Inspected By: JM Testing Equipment: Humboldt Scale Model H-4620 The test results presented here reflect the condition of the roof system at the time of the test. These results are time and sample dependent since roof condition are continuously changing due to the exposure to the element and roof top traffic. Client recognizes that actual conditions in areas not tested by DEC may differ from those anticipated in DEC's report. Client understands and accepts that this can significantly increase the cost of construction for its future projects. Client agrees that DEC shall not be responsible or liable for any variations in the actual conditions of areas not tested by DEC. Test No. Test Location Field Uplift Pull Test Test Result 1 - 93 Field See Sketch Below > Than 35 LBS Passed 94 - 109 Corner See Sketch Below > Than 35 LBS Passed 110 - 169 Perimeter See Sketch Below > Than 35 LBS Passed 170 - 224 Ridge caps See Sketch Below > Than 35 LBS Passed ROOF TILE UPLIFT IN ACCORDANCE WITH FLORIDA BUILDING CODE TEST PROTOCOL TAS-106 ROOF SKETCH SEE PAGE 2 FOR ROOF SKETCH --Sinc- ours, /O/30/26!6' Wissam : amani, P.E. DYNA ECH ENGINEERING CORP. Florida Reg. No. 39584 Special Inspector No. 757 750 WEST B4TH STREET. HIALEAH. FL 33014 PHONE (305) 828-7499 FAX (305) 828-9598 EMAIL:INFOODYNATECHENGINEERING.COM k EC r � Page 1 of 2 14b 147 146 149 150 17 62 66 65 67 6 0 68 61 181 63 69 60 132 77 1=• 1:6 1151 79 1 64 :4 i 187 59 � �54 i 01 145/. 1 55 71 58 70 144 53 d6 56 72 189 1431 52 73 157 51 190 1421 1 50 78 76 r 1155 75 I 1156 741 152 1153 1154 24 I 160 159193 170 ,87 1581 92 161 162 195 89 91 88 80 81 i72 82 1163 90 1164 17>1165 157, 86 85 84 83166 97 1 169 166 167 196 130 131 132 02 128 129 1 47 48 49.4 135 136 1 134 I 2 42 133 J 41 35 36 2 37 21 38 34 8 7 30 • 40 21 • 45 44 • 39 • 29 • 24 25 26 '21+ , 27 199 14 2u0 13 201 12 11 9 1 137 33 1 138 32 139 1 1'Y 2 3 2 6 15 16 17 18 19 20 07 9 1 117 10 1 4 118 S 124 123 122 121 120 119 , 1 116 114 '108 ee 6 7 113 2 I 112 2 31 _ L 1 110 111 ,10 Dynatech Engineering Corp. Page: 2 of 2 Client: OBENOUR ROOFING & SHEET METAL Scale: N.T.S. Project: 533 GRAND CONCOURSE MIAMI SHORES, FL 33138 Date: 10-29-2018