Loading...
RF-16-2685Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Permit us Date: 10/11/2016 Permit NO. RP-9-16-2685 Permit Type: Roof Work Classification Tile/Flat Permit Status: APPROVED Expiration: 04/09/2017 9707 NE 5 Avenue Road Miami Shores, FL 33138-2444 Parcel Number 1132060180030 Block: Lot: Applicant OLIVER DI PIETRO Owner Information Address Phone Cell OLIVER DI PIETRO 9707 5 Avenue Road MIAMI SHORES FL 33138- Contractor(s) INNOVATIVE ROOFING Phone (954)324-5825 Cell Phone Valutsflit $ 35,450.00 Total Sq Feet: ` 5460 Type of Work: Re Roof Additional Info: REPLACE ENTIRE ROOF TILE AND FLAT Classification: Residential Scanning: 3 Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $21.60 $5.63 $5.63 $7.20 $375.00 $9.00 $28.80 $452.86 CANCEL( Pay Date Pay Type Invoice # RF-9-16-61532 10/11/2016 Check #: 4595 09/30/2016 Check #: 4543 Amt Paid Amt Due $ 402.86 $ 50.00 $ 50.00 $ 0.00 Available Inspections: Inspection Type: Up Lift Report Tin Cap Final Roof Tile In Progress Roof in Progress Renailing Affidavit Review Roof Cap Sheet In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to cjo the work stied. October 11, 2016 Authorized Signature: Owner / Applicant / Contractor / Agent Date Building Department Copy October 11, 2016 1 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 Master Permit N ROOFING ❑ REVISION ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS JOB ADDRESS: g10-7 NG SApi 'Foca City: Miami Shores Folio/Parcel#: Is the Building Historically Designated: Yes Occupancy Type: Load: Construction Type: Flood Zone: ❑ RENE AL ❑ SHOP DRAWINGS NO BFE: FFE: /� liver f OWNER: Name (Fee Simple Titleholder): G I e+vv Phone#: 33 (2' Address: City: (ate% StsU^Qit Tenant/Lessee Name: /44- Email: State: c(--- CONTRACTOR: Company Name: I nnG%,&)) rr..t %Lco f I Address: 37 L20 N ' ?7 _ l oo City: POM Palo 73stcch State: ��- Qualifier Name: —Soft." K-ur-1nk✓ State Certification or Registration #: C C C (3 ZQce 5 6 DESIGNER: Architect/Engineer: ('► 1 yA-- Address: t r Value of Work for this Permit: $ � 9 50 • 0 Type of Work: ❑ Addition ❑ Alteration ❑ Description of Work: Sub Permit No. ❑ CHANGE OF CONTRACTOR County: Miami Dade Zip: N (4- Phone#: Phone#: Zip. •31CGk f Phone#: q)'-t2gi'v1,4S- Certificate of Competency #: Phone#: N 1/4- City: State: "tAZip: ki (4- Square/Linear Footage of Work: "59(a 0 New ❑ Repeplace ❑ Demolition Specify color o color thru tile: ��v-� Submittal Fee $ w .5-R- 5 CCF $ 2. I •%d CO/CC $ Scanning Fee $ c/, S'.` (03 Permit Fee $ Radon Fee $ Technology Fee $ 26 • 0 Structural Reviews $ RECEIVED SEP802'16 BY: ❑ EXTENSION BC 2014 2L �s5 ❑ CANCELLATION Zip: DBPR$ 5.(o3 Notary$ Training/Education Fee $ '9- • W Double Fee _ $ Bond $ y /3445 TOTAL FEE NOW DUE $ ( • (Revised02/24/2014) OWNER or AGENT me or who has produced Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) �, Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S1AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject • _ • hment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspectio ' which occu seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be • pproved an • • reinspection fee will be charged. Signatu Signature ONTRACTOR The fore ing instrument was acknowledged before me this The foregoing' str men was acknowledged before me this day of cWY , 20J by g ''day of 20 / , by who is personally known to Ohgv , who is personally known to DL-" identification and who did take an oath. NOTARY PUBLIC: Sign: Print: as me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Seal: ,;R��U CARRIE LYNN BOLDING Seal: MY COMMISSION # EE878483 "!�� EXPIRES April 27, 2017 *********, 9:4t0104**** onir Alaalrsaa ****_*********************** APPROVED BY Plans Examiner sp %11 � � I f �/ bId CARRIE LYNN BOL '= MY COMMISSION # EE878483 EXPIRES April 27, 2017 Zoning (Revised02/24/2014) Structural Review Clerk S,+E G STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION ";, CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-1395 '� pD LLE 2601 BLAIR STONE ROAD � TALLAHASSEE FL 32399-0783 KUCHLER, JOHN INNOVATIVE ROOFING INC 23119 SW 55TH AVE BOCA RATON FL 33433 Congratulations! With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Honda's economy strong. Every day we work to improve the way we do business in order to serve you better. For information about our services, please log onto www.myfloridalicense.com. There you can find more information about our divisions and the regulations that impact you, subscribe to department newsletters and learn more about the Department's initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, and congratulations on your new license! RICK SCOTT, GOVERNOR STATE OF FLORIDA _ DEPARTMENT.OF BUSINESS AND PROFESSIONALREGULATION CCC1329658 _ 'ISSUED:., .08/24/2016 CERTIFIED ROOFING SONTRACTOR KUCHLER, JOHNS`;: `- ', :..: i INNOVATIVE ROOFING?:INC IS CERTIFIED under the provisions of Ch.489 FS. Expiration date . AUG 31, 2018 L1608240006826 DETACH HERE KEN LAWSON, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD LICENSE NUMBER The ROOFING CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2018 KUCHLER, JOHN INNOVATIVE ROOFING INC4„ 3260 NW 23 AVE SUITE300E POMPANO B OtSM69� ISSUED: -0812412016 D{'SPLAIAS REQUIRED BY`L`"AC ' SEQ # L1608240000826 BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895 — 954-831-4000 VALID OCTOBER 1, 2016 THROUGH SEPTEMBER 30, 2017 DBA: Business Name: INNOVATIVE ROOFING INC Owner Name: JOHN KUCHLER Business Location: 3260 NW 23 AVE STE #300E POMPANO BEACH Business Phone: 954-429-8845 Rooms Seats Employees 5 Receipt#:ROOF NG/SHEET METAL CONTRACTOR Business Type: (CERT ROOFING CONTRACTOR) Business Opened:o2/o3/2o11 StatelCounty/Cert/Reg:00013 2 9 6 5 8 Exemption Code: Machines Professionals For Vending Business Only Number of Machines: Vending Type: Tax Amount Transfer Fee NSF Fee Penalty Prior Years Collection Cost Total Paid 27.00 0.00 0.00 0.00 0.00 0.00 27.00 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is non -regulatory in nature. You must meet all County and/or Municipality planning WHEN VALIDATED and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations. Mailing Address: JOHN KUCHLER 3260 NW 23 AVE STE #300E POMPANO BEACH, FL 33069 2016 - 2017 Receipt #04B-15-00007743 Paid 08/30/2016 27.00 BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895 — 954-831-4000 VALID OCTOBER 1, 2016 THROUGH SEPTEMBER 30, 2017 DBA: INNOVATIVE ROOFING INC Business Name: Owner Name: JOHN KUCHLER Business Location: 3260 NW 23 AVE STE #300E POMPANO BEACH Business Phone: 954-429-8845 Rooms Seats Employees 5 Receipt #: 185-238936 Business Type: ROOFING/SHEET METAL CONTRACTOR (CERT ROOFING CONTRACTOR) Business Opened: 02/03/2011 State/County/Cert/Reg: CCC1329658 Exemption Code: Machines Professionals Signature • For Vending Business Only Vending Type: Tax Amount Transfer Fee NSF Fee Penalty Prior Years Collection Cost Total Paid 27.00 0.00 0.00 0.00 0.00 0.00 27.00 Receipt #04B-15-00007743 Paid 08/30/2016 27.00 ACC o® CERTIFICATE OF LIABILITY INSURANCE ATE D o�a�2oD 16 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.' THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Frank H. Furman, Inc. 1314 East Atlantic Blvd. P. O. Box 1927 Pompano Beach FL 33061 CONTACT Tina Shannon NAME: PHCON No.). (954) 943-5050 jac,No): (954)942-6310 E-MAIL ti ADDRESS: ne@furmaninsurance.com INSURER(S) AFFORDING COVERAGE NAIC # INSURERA AmTrust Int' 1 Underwriters Ltd INSURED Innovative Roofing , Inc . 3260 NW 23rd Avenue Suite #300 Pompano Beach FL 33069 INSURER B WesCo Insurance Company 25011 INSURER C : INSURERD: INSURERE: INSURERF: COVERAGES CERTIFICATE NUMBER:2016 Master Liability REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADOL INSD SUBR WVD POLICY NUMBER POLICY EFF IMMIDD/YYYY) POLICY EXP IMMIDD/YYYY) LIMITS A X COMMERCIAL GENERAL LIABILITY PAL104492802 1/25/2016 1/25/2017 EACH OCCURRENCE $ 1,000,000 CLAIMS -MADE X OCCUR DAMAGE TO RENTED PREMISES PREMISES (Ea occurrence) $ MED EXP (Any one person) $ 5,000 PERSONAL&ADVINJURY $ 1,000,000 GEN'L X AGGREGATE POLICY OTHER: LIMIT APPLIES PRO- JECT PER: LOC GENERAL AGGREGATE $ 2,000,000 PRODUCTS - COMP/OP AGG $ 2,000,000 $ B AUTOMOBILE X X LIABILITY ANY AUTO ALL OWNED B SCHEDULED WPP1438391 2/3/2016 2/3/2017 COMBINED SINGLE LIMIT (Ea accident), $ 1,000,000 BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (Per accident) $ PIP -Basic $ UMBRELLA LIAB EXCESS LIAB O OCCUR CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ DED RETENTION $ $ WORKERS COMPENSATION AND EMPLOYERS' UABIUTY ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory In NH) If yes, describe under DESCRIPTION OF OPERATIONS below Y / N N 1 A PER STATUTE OTH- ER E.L. EACH ACCIDENT $ E.L. DISEASE - EA EMPLOYEE $ E.L. DISEASE - POLICY LIMIT $ DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) State of Florida Roofing Contractor CCC1329658 CERTIFICATE HOLDER CANCELLATION 13057568972@efaxsend.com Miami Shores Village SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 10050 NE 2nd Avenue Miami Shores, FL 33138 AUTHORIZED REPRESENTATIVE Dirk DeJong/KJL ..ea...--C, 47 -40°4----- ACORD 25 (2014/01) INS025 0014011 © 1988-2014 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD Value of Work for this Permit: $ 35,450.00 1 BUILDING PERMIT APPLICATION QUILDING ❑ ELECTRIC PLUMBING ❑ MECHANICAL Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECEIVED C0(2Lfr. BY: FBC2`0�1� Master Permit No. ,41 1 — LI Sub Permit No. ❑ REVISION ❑PUBLIC WORKS ❑ CHANGE OF CONTRACTOR JOB ADDRESS: 9707 NW 5th Ave Road City: Miami Shores County: ❑ EXTENSION ❑ RENEWAL ❑ CANCELLATION ❑ SHOP DRAWINGS Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes Occupancy Type: HOME Load: Construction Type: Flood Zone: BFE: OWNER: Name (Fee Simple Titleholder): Oliver Di Pietro Address:9707 N 5th Ave Road Phone#:fin - 301 - a?I10 City: Miami Shores Tenant/Lessee Name: nia State: FL Email: Anthony@ircsouthflorida.com Zip: 33138 Phone#: 954-369-8691 CONTRACTOR: Company Name: Innovative Roofing, Inc. Phone#: 954-429-8845 Address: 3260 NW 23 Ave, #300E City: Pompano Beach State: FL Zip: 33 Qualifier Name: John Kuchler 169 Phone#: 954 o `� •. i CCC1329658 ;-911 I.F� t_ r' State Certification or Registration #: Certificate of Competency #: ° DESIGNER: Architect/Engineer: nia Phone#: Address: nia City: Ilia State: nia zip:�[n//aa Square/Linear Footage of Work:- 0 " 60 Type of Work: CIAddition ❑ Alteration ❑ New Description of Work: Replace Entire Roof 'rj le 4 t ak ■❑ Repair/Replace ❑ Demolition Specify color of color'thru'tile':. IJPis) Mt- &CZ Submittal Fee Permit Fee $ 11009, CCF $ Scanning Fee $ Technology Fee $ Structural Reviews $ Radon Fee $ DBPR $ CO/CC $ Notary $ Training/Education Fee $ Double Fee $ Bond $ SO TOTAL FEE NOW DUE $902 • 36 (Revised02/24/2014) Bonding Company's Name (if applicable) n/a Bonding Company's Address nia City nia State n/a Zip n/a Mortgage Lender's Name (if applicable) Ilia Mortgage Lender's Address n/a City Ilia State nia Zip n/a Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to atta for the first inspection whi inspection will not be approv t. Also, a certified copy of the recorded notice of commencement must be posted at the job site (7) days after the building permit is issued. In the absence of such posted notice, the spection fee will be charged. OWNER or AGENT The foregoing instrument was acknowledged before me this n day of , 20 I LI" , by O'Au I✓ . DI P4.eA-rb, who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: 0619-44-1-- \ Signature TRACTOR The fore:'fF strument was acknowledged before me this , 20 , by 23 day of 1 1' is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: a MARILYN ANN CA SANG` .. ar i;)201; bonded Thru Budget Notary Services OF F� fi; rT� **** **** *## #********* *itm'n co ********************ilia********************i ***************************iti **,:*** * 8 Oa CC § A 22 Plans Examiner Zoning APPROVED BY v CASAPtOVI. o PpY PUB�,c t.AAHILYNIAS ON # EE Otb56 } COMM EXPIRES'. September t Se2p1.. `0 P ale ') Bonded Thu BudgetNotary F Sign: Print: Seal: (Revised02/24/2014) Structural Review Clerk INNOVATIVE OOF1ING Attention: Mr. & Mrs. Di Pietro Address: Di Pietro Residence — Miami Shores (RE -ROOF PROPOSAL) Price: Thirty -Five Thousand Four -Hundred and Fifty -Dollars & Zero Cents Total Proposal: S35,450.00 PAYMENTS: - 10% upon commencement - $3,545,00 - 50% when mopped -in — $17,725.00 - 40% upon final by city - $14,180.00 Date : June 6, 2014 (JOB SCOPE — SLOPED ROOF REPLACEMENT) 1. Innovative will setup and stage job site accordingly (cover and protect driveways, pool, air conditioning units etc.). 2. Innovative will remove the existing roof system, down to the wood substrate, and a smooth workable surface. 3. Innovative will re -nail wood deck, as per Building Code. 4. Innovative will replace up to 256 sq.ft of plywood decking, at no additional cost to owner. 5. Innovative will furnish, nail and tin -cap one (1) layer of new #30 felt membrane, over existing plywood deck, which will meet or exceed Local Building Code. 6. Innovative will then furnish and install new 26 gauge Galvanized 3"x3" eave drip, along perimeter edge, as per Local Building Code. 7. Innovative will also furnish and install new 16' galvanized valley metal, where applicable, as per Local Building Code. 8. Innovative will furnish and install new all-purpose roof vents, where applicable, as per Local Code. 9. Innovative will furnish and install new galvanized 5"x7" L-Flashing, at all walls and return areas.* 10. Innovative will then furnish and install, in steep asphalt, one (1) layer of Tamko Awaplan. Tile Underlayment, as per Local Building Code. 11. All laps and seams of newly installed membrane will be re -checked for water -tight integrity. 12. Innovative will furnish and install new lead flashing for all plumbing stacks, if required and per Local Building Code. 13. Innovative will then furnish and install, with PolyFoam PolySet foam adhesive, a Standard Concrete Tile, over entire sloped roof area, as per Local Building Code.** 14. Premises are to be left in a clean condition, at the end of every working day. 3260 NW 23 Avenue, Suite #300E • Pompano Beach, FL 33069 • Office (954) 429-8845 • Fax (954) 532-4980 • License #CCC1329658 (GAF N-B-4-M ON WOOD DECK ROOF SCOPE) I. We will remove the existing roof system down to the wood deck and smooth workable surface. 2. We will then fasten a GAF #75 lb. base sheet with 1 ''A" Ring Shank nails and Tin Caps as per current South Florida Building Code. 3. Over entire roof area mop down solid with hot asphalt one layers of GAF Rubberoid 20 as per current South Florida Building Code. 4. Install new 26 gage 3"X3" color TBD eave drip at roof perimeter as per current code. 5. Over entire roof mop down solid with hot asphalt one layer of GAF Mineral Surfaced Cap Sheet as per current South Florida Building Code. 6. Install new lead flashing around all existing plumbing pipe penetrations as per current South Florida Building Code. 7. Premises are to be left in a clean condition, free from all roofing debris. *NOTES* 1. Any additional wood replacement over the allotted proposed a. $50.00 per Sheet of Plywood b. $3.50 per lin. Ft. 1x6 T&G decking. c. $4.00 a lin. Ft. for 2" X 4" rafters. d. $3.25 a lin. Ft for wood fascia. 2. 2'X4' DADE COUNTY APPROVED SKYLIGHT WILL BE AN ADDITIONAL $400.00 PER SKYLIGHT 3. IF CUSTOM SKYLIGHT IS DESIRED, HOMEOWNER TO PROVIDE DIMENSION AND A PRICE WILL BE FURNISHED FROM THE MANUFACTURER. 4. INNOVATIVE WILL SEAL NEW HOOD VENT FROM ROOF LINE UP , TO BE SUPPLIED BY PLUMBING CONTRACTOR 5. CONTRACT PRICE INCLUDES ALL MATERIAL AND LABOR FOR ALL JOB SCOPE ITEMS LISTED ABOVE. 6. CITY COST FOR PERMIT, IS INCLUDED IN CONTRACT PRICE 7. ALL ENGINEERING, CALCULATIONS AND PRODUCT CONTROL TESTING FOR ROOFING IS INCLUDED UNDER CONTRACT PRICE. 8. CONTRACT DOES NOT INCLUDE ANY GUTTER REMOVAL/REPLACEMENT, IF REQUIRED. 9. ALL WORK WILL BE PERFORMED ACCORDING TO OSHA SAFETY REGULATIONS. 10. NO WORK WILL BE PERFORMED IN INCLEMENT WEATHER CONDITIONS. *GUARANTEES* Slope / Flat ALL WORKMANSHIP AND MATERIAL WILL BE GUARANTEED FOR (15) YEARS FOR THE SLOPE AND (10) YEARS FOR THE FLAT FROM DATE OF COMPLETION, BY INNOVATIVE ROOFING CONCEPTS, INC. CONTRACTOR WILL REPLACE FAULTY MATERIAL OR FAULTY WORKMANSHIP WITH -IN THE PERIOD FREE OF CHARGE. Innovative Roofing, Inc. Anthony M. Kuchler: Date: 6 — y Owner/Authorized Ag Date: c , / 3260 NW 23 Avenue, Suite #300E • Pompano Beach, FL 33069.Office (954) 429-8845 • Fax (954) 532-4980 • License #CCC1329658 L PROJECT PROVISIONS a. Guideline: The project will be constructed in strict conformance to the plans and specifications, which have been Examined and approved by the Owner. b. Compliance: The project will be completed in strict compliance with all laws, ordinances, rules and regulations of the authorities. c. Control: The agreement, plans, and specifications are intended to supplement each other. In case of conflict, the specifications and the agreement provisions will control both. d. Change Orders: As directed by the Owner, construction lender, public body or Inspector, any alteration or deviation involves extra cost (subcontract, labor, and materials) will be executed only upon the parties entering into a written pay for expense incurred because of unusual or unanticipated conditions. e. Allowances: If the agreement price allowances, and the cost of performing the work is greater or less than this agreement price will be adjusted accordingly. II. FINANCIAL RIGHTS AND RESPONSIBILITIES a. Labor and Material: Contractor will provide and pay for all labor and materials necessary to complete the Project. this obligation for expenses inured when the Owner is in arrears in making progress payments. b. Permits: Contractor will obtain and pay for all required permits and licenses. c. Taxes, Assessments and Charges: owner will pay Taxes, special assessments of all descriptions and charges required by public bodies and utilities. d. Bankruptcy: If either party becomes bankrupt, the other party has the right to cancel this agreement. applicable government plans will control the from the specifications that change order. The owner will allowance, then the OWNERS RIGHTS AND RESPONSIBILITIES Contractor is released from a. Cancellation: Owner has the unconditional right to cancel the agreement, without penalty or obligation, until midnight of the third business day after the agreement was signed. Cancellation must be done in writing. Upon cancellation, any property traded in, any payments made under this agreement, and the contractor will return any negotiable instrument executed within 10 business days following receipt of the cancellation notice. b. Property lines: Owner shall locate and point out property lines to the contractor. Contractor may, at his option, require the Owner to provide a licensed land surveyor's map of the property. c. Liens: Failure to pay persons supplying materials or services according to the terms of this agreement may result in the filing of mechanic' liens on the affected property. Owner has the right to ask the contractor for lien waivers from all persons supplying these materials or services. In the event any mechanics lien is filed through no fault of the owner, then the contractor agrees to take all steps necessary for the release and discharge of such lien. d. Insurance: Owner will maintain property damage insurance at least equal to the Agreement price. e. Damage to Project: Contractor will not be responsible for any damage caused by the owner, or other causes beyond the control of the contractor. Owner will pay for any restoration work. IV. CONTRACTORS RIGHTS AND RESPONSIBILITIES a. Delay: Contractor will be excused for any delay beyond his reasonable control. These delays may include but are not disputes, inclement weather, acts of public authority, acts of the owner, or other unforeseen contingencies. b. Right to Stop Work: If any payment under this agreement is not made when due, the contractor may suspend work payments due have been made. Any failure to make payment is subject to a claim enforced against the property in accordance with c. Substitution of materials: Contractor may substitute materials without notice to the owner in order to allow work to substituted materials are of no lesser quality than those listed in the specifications. d. Salvage: All salvage resulting from work under this agreement is to be retained by the contractor unless other agreements specifications. e. Insurance: Contractor will maintain workers' disability compensation insurance for his employees and comprehensive policies. V. COMPLETION OF PROJECT a. Notice: Owner agrees to sign a Notice of Completion within five days of completion of the project. If the project passes Owner does not sign the Notice, the contractor may act as the Owners agent and sign the Notice. b. Clean-up: Contractor is responsible for removing debris and surplus material from the property, and leaving the orderly condition. VI. CONFLICT RESOLUTION limited to act of god, labor until such time as all the applicable lien laws. proceed, provided that the are contained in the written public liability insurance final inspection and the property in a neat and a. Arbitration: Any controversy or claim arising out of this Agreement that cannot be resolved, is subject to arbitration, with an arbitrator of mutual agreement, and all parties (including Owner, Contractor, Architect, and Sub -contractors) are bound to this arbitration. If any party does not appear at arbitration proceedings, the arbitrator is empowered to decide the controversy in accordance with whatever evidence is presented by the party(ies) that do participate. b. Attorney fees: If either party becomes involved in litigation arising out of this agreement, the court shall award attorney fees to the prevailing party. c. Limitations: No action related to this project may be made by either party against the other more than 2 years after VII. GENERAL PROVISIONS a. agreement. b. Prohibition of Assignment: Neither party may assign this agreement or payment due under this agreement without other party. c. Qualification: This document constitutes the entire agreement of the parties. No other agreements exist. This only by written agreement signed by both parties. d. Governance: This agreement shall be construed in accordance with and governed by the laws of the state in which the We will use caution during installation and will not be responsible for damages to interior or interior contents, landscaping, sidewalks, underground lines, except for proven negligence. It is recommended that accessible items around the exterior be placed inside furnishings in rooms with "open seam" which might be damaged from vibration be removed or secured. Items such as screen/patio enclosure, solar system, air conditioning system, guttering which may require removal and included in this contract unless specified therein. Notice: Any notice required or permitted under this Agreement may be given by certified or registered mail at the costs/expenses including completion of work. addresses contained in the the written consent of the agreement can be modified project is located. pool, patios, driveways, ceilings be covered, items reinstallation are not 3260 NW 23 Avenue, Suite #300E • Pompano Beach, FL 33069.Office (954) 429-8845 • Fax (954) 532-4980 • License #CCC1329658 It is agreed that the contract p based upon the belief that the structure is sound and built in accordance with local building codes. Additional costs to correct any of thesthe customer's responsibility. Customer: Date: 3260 NW 23 Avenue, Suite #300E • Pompano Beach, FL 33069 • Office (954) 429-8845 • Fax (954) 532-4980 • License #CCC1329658 Jun. 24. 2.014 F:25PM No.2309 P. 4/4 .4 o CERTIFICATE OF LIABILITY INSURANCE - DATE(MMIDD/YYYYI 1/23/2014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. HOLDER. THIS BY THE POLICIES AUTHORIZED IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the pollcy(les) must he endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy. certain policies may require an endorsement. A statement on This certificate does not confer rights to the certificate holder In Ileu of such endorsemeni(s). PRODUCER Frank H. Furman, Ino, 1314 East Atlantio Blvd. P. 0. Box 1927 Pompano Beach FL 33061 CONTACT • PN1AjMN£E: i/1IC Ne FYll, (954) 943-5050 FAX pm. NoE (95g943-543.7 E-MAIL ADDRESS: INSURER(SI AFFORDING COVERAGE NAIL INsuRERAAmtrvat International Underwrit 08072 INSURED Innovative Roofing, Ino, 3260 NW 23rd Arenia Suite ft300 Pompano Beach FL 33069 rnummAr_e ,.-.,,....._.___..._____ _ ___ INSURER B : WSURERC: INSURER O: INSURERS: INSURER F: INSR LYR REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. TYPE OF INSURANCE A GENERAL LIABILITY COMMERCIAL GENERAL LIABILITY CLAIMS -MADE n OCCUR Primary Non -Contributory x X GEN'LAGGREGATE LIMIT APPLIES PER —I POLICY 1 1 JPP inc AUTOMORILE UABILITY ANY AUTO ALL MANED AUTOS HIRED AUros UMBRELLA UAa EXCESS LIAR AAuTOSL&ED NON -OWNED AUTOS ADM UR SUER Mein .d an POLICY NUMBER (MI4YU0/YYYYI PAT104492900 1/25/2014 IMWD/D!YYXYY) 1/25/2015 LIMITS EACH OCCURRENCE UAMAGETO RENTED PREMISES (ERLosorrenom MED EXP (Any one person) PERSONAL &ADV INJURY S 1,000,000 S 100,000 5 5,000 $ 1,000,000 GENERAL AGGREGATE 5 2,000,000 PRODUCTS -COMP/OP AGG $ 2,000,000 COMBINED STIIOtEIIM(r (Eaacddenh BODILY INJURY (Perper) S -5 BODILY INJURY (PeracOdenI) PROPERTY DAMAGE (Para:ciient) S DEO 1 1 RETENTIONS OCCUR CLAIMS -,MADE WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Y IN ANY PROPRIETOR/PARTNER/EXECUTIVE El OFFICER/MEueER EkCLUoED? (Mandatory In NH) If yes. deeteibetneer D $ RIPTION OF OPERATIONS below N/A EACH OCCURRENCE S AGGREGATE 5 WGSTATU- I TORY I (HITS E.L EACH ACCIDENT OTH- ER i 5 EL, DISEASE - EA EMPLOYEE 5 E.L. DISEASE - POUCY UMIT 5 3tateTTON OF Florida ERA OPERATIONS / LOCATIONS / VEHICLES (Attach ACORO 101, Addlllonal Remarks Schedule, If more space Is required) Roofing Contractor CERTIFICATE HOLDER (954) 429-8936 City of Miami Shores Building Department 10050 NE 2nd Ave. Miami Shores, FL 33138-2304 ACORD 25 (2010►05) INan2S/ m mm CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTNORI2ED REPRESENTATIVE Dirk DoJong/CS ®1988.2010ACORD CORPORATION. All rights reserved. Th. Armen namo and Inns AYA ronit1ArAr1 marina of Af 11Rr1 Jun. 24. 2014 • 1:25PM No. 2309 P. 3/4 ACOR DATE 0 M DONYYYI 2 13/2014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. CERTIFICATE OF LIABILITY INSURANCE IMPORTANT: Il the cerllltcate holder is an ADDITIONAL INSURED, the pollcy (les) must be endorsed. If SUBROGATION IS WAIVED, eubJect to the terms end conditions of the policy, certain policies mey require an endorsement. A statement on Ihls certificate does not confer rights to the certificate holder In lleu of Such endoreement(e)- PRODUCER FRANKCRUM INSURANCE AGENCY. INC. 100 S. MISSOURI AVE. CLEARWATER FL 33756 INSURED FrenkCrum 1-800-277-1620 100 S MISSOURI AVENUE CLEARWATER FL 33756 COVERAGES COLTACY ■Rile PAFAa Ems 1-300-277-1620 s4800 727-747-0704 swat. CORM INSURER(5) AFFORDING COVERAOE INSUR ER FRANK WINSTON CRUM INSURANCE CO. INSURER It HAW, 11500 INSURER C: INSURER 0: INSURER E: INSURER F: • "+"..". RGVIaIt fl NUMntI THI81S TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW NAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTW THSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT To VMICH THIS CER11RCATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED DY THE POLICIES DESCRIBED HEREIN 13 SUBJECT To ALL THE TERMS, EiCLVS10NS AND CONDITIONS OP SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. vox LYA TYPE OF INSURANCE ADDL SUER POLICYHLNIBER POUCYEFF POUCYEXP um% W O (LLS�Y) (YNADlwYYYY) UNn7 OENERAL UAARr1Y EACH oottu limos 6 COSIMRRCIAL GENERAL UASWTY 01L 3E TO RFlITEO PREdlfiEA(Es ea:uwi a) 3 - cwlasaulDE OCCURNEO mm Okay ow paw) $ PERSONAL AIN DIARY 8 4 /dem.AGGREGATE( t CEHL AteRE:ATE UI�uIY A�ppuED - 1 1PRLVECT I 1LOC $ AUTOYOSe,E wBllriY - COWERED SIN6CE0� (E..4/1•0) t Airy WO BOaLY INJURY (Pm ALL awe) AII/OSAure SCHEDU,cn perAe,) $ BoaL'INJURY (Drr.cdd.q i 1IREO AUTOS NON ALIT O PROPERTY DAi4[LE - 1N) $ i umaREIA.ALVe OCCUR EACH OCCURRENCE i EXCESS LIAR CWLTS.1/ADEI AGORCEkrD 1 Deal I RETFIAIONr i A WORREASCOMPENSATI0NARO CYPLOYER3' LIABILITY YRI WC201400000 1/12014 1/1/2015 OT14 BTU"el 1 mT X TORY Laej ANYPROMIETOR NFITNER4EAECVRYE ohT10EWVE1LAER E(C&UOED1 1 NIA EL, EACHACcoEM 8T,000,000 w.laaay n IIN) Ilya, amiss /Ma ' oEecRPTIONOFOPERATIOIIBbeim, ELOgFJIBE-EAE16wTEE 51.000,000 AL catema-pouNYLe9Y 81,000.000 DESCRIPTION OF OPERATIONS/ LOCATIONS I VEHICLES (An.d, WAD 1 1, A $ mI Reouis Sa0e0Aq Y n.rs spas. rr rep,Lra) EFFECTIVE 06/27/2012, COVERAGE IS FOR 100% OF THE EMPLOYEES OF FRANKCRUM LEASED TO INNOVATIVE ROOFING INC. (CUENT) FOR WHOM THE' CUENT IS REPORTING HOURS TO FRANKCRUM. COVERAGE IS NOT EXTENDED TO STATUTORY EMPLOYEES. CERTIFICATE HOLDER fAA,CB, r Arnu MIAMI SHORES VILLAGE 10050 NE 2NDAVENUE MIAMI SHORES, FL 33135 ACORD 26 (201Wa) SHOULD ANY OF THE ABOVE DESCRIDco POLICIES BE CANCELLED BEFORE THE EXFIRATIoN DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS, ANTIIOWIED REPRESENTATIVE The' ACORD name KM iopo are realelored Mirka o1 ACORD 0 1968,2010 ACORD CORPORATION. All rigble ree0Yed. THIS DOCUMENT HAS A COLORED BACKGROUND • ?A ICROPRINTING • LINEPAARICr PATENTED PAPER BATCH NUMBER REM .LAWSON SECRETARY KtiWAKU-�= N-FY-1.-f.I:AL-1:3-LISINtSS FAX KteE1} 7 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895 — 954-831-4000 VALID OCTOBER 1,2013 THROUGH SEPTEMBER 30,2014 DBA: Business Name: INNOVATIVE ROOFING CONCEPTS INC Owner Name: Join KUCH'LER Business Opened:02/03/2011 Business Location: 3260 NW 23 AVE STB #>~300E State!County/Cert/Reg:CCc1329658 POMPANO BEACH Exemption Code: Business Phone: 954-429-8845 Receipt #:ROOF NG/SHEET PIETAL CON Business Type: (CERT ROOFING CONTRACTO Rooms Seats Employees Machines Professionals 5 Tax Amount 27.00 For Venirng Business Only Number of Machines: Vending Type: NSF Fee Penalty Prior Years Collection Cost Transfer Fee 0.00 0.00 0.00 I 0.00 0.00 Toter Paid 27.00 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT WHEN VALIDATED This tax is levied for the privilege of doing business within Braward County and is non -regulatory in nature. You must meet all County and/or Municipality planning and zoning requirements, This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in compliance with State or focal laws and regulations. Mailing Address_ INNOVATIVE ROOFING CONCEPTS INC 3260 NW 23 AVE STE #300E POMPANO BEACH, FIB 33069 2013 - 2014 Receipt #03B-12-00011672 Paid 08/12/2013 27.00 ACCP d CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY) 09/23/2016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy (ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER FrankCrum Insurance Agency, Inc. 100 South Missouri Avenue Clearwater, FL 33756 CONTACT NAME: PHONE (A/C, No, Ext): 1-800-277-1620 x4800 FAX (A/C, No): (727) 797-0704 E-MAIL ADDRESS: INSURER(S) AFFORDING COVERAGE NAIL# INSURER A: Frank Winston Crum Insurance Co. 11600 INSURED FrankCrum UC/F Innovative Roofing Inc. 100 South Missouri Avenue Clearwater, FL 33756 INSURER B: INSURER C: INSURER D: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: 370552 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN SSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POUCIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL INSRD SUER WVD POUCY NUMBER POLICY EFF (MM/DDIYYY`n POLICY EXP (MMIDDIYYTY) UMITS COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ CLAIMS -MADE OCCUR PREMI ETORENTED PREMISES (Ea occurrence) $ MED EXP (Any one person) $ GEN'L PERSONAL & ADV INJURY $ AGGREGATE UMIT APPUES PER: POLICY PROJECT LOC OTHER: GENERAL AGGREGATE $ PRODUCTS-COMP/OP AGG $ $ AUTOMOBILE UABILITY ANY AUTO OWNED AUTOS ONLY HIRED AUTOS - SCHEDULED AUTOS NON -OWNED AUTOS ONLY COMBINED SINGLE LIMIT (Ea accident)_ $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ - PROPERTY DAMAGE (Per accident) $ -.ONLY - UMBRELLA LIAR EXCESS UAB OCCUR CLAIMS -MADE EACH OCURRENCE $ AGGREGATE $ DED RETENTION $ $ A WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory in NH) If yes, describe under DESCRIPTION OF OPERATIONS below Y/N N/A WC201600000 01/01/2016 01/01/2017 X PER STATUTE OTH- ER E.L. EACH ACCIDENT $1,000,000 I E.L. DISEASE -EA EMPLOYEE $1,000,000 E.L. DISEASE-POUCY UMIT $1,000,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached it more space is required Effective 06/27/2012, coverage is for 100% of the employees of FrankCrum leased to Innovative Roofing Inc. (Client) for whom the client is reporting hours to FrankCrum. Coverage is not extended to statutory employees. CERTIFICATE HOLDER CANCELLATION Village of Miami Shores 10050 NE 2nd Avenue Miami Shores, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE (NTH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ��J''� am' ACORD 26 (2016/03) The ACORD name and logo are registered marks of ACORD ©1988-2016 ACORD CORPORATION. All rights reserved. Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RE: Permit # R (' 4- 1 1 3 4 E. DATE: INSPECTION AFFIDAVIT licensed as a (n) Contractor / Engineer / Architect, (Print name and circle License Type) License #: C.cC 13 -2 9 Le On or about %/ 41 /I ►2 ; 3 W P"" (Date & time) work at FS 468 Building Inspector , I did personally inspect a roof deck nailin iin N S �4i.d %Zcga t►4, S IAc�t�J (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned. Swom to and subscribed before me this Notary Public, Sate of Florida at Larg day of `.1PR •fe�i MARIA TALERICO Notary Public - State of Florida My Comm. Expires Jan 11, 2016 .yr.+ Commission # EE 139865 Bonded Through National Notary Assn. *General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs o permit # and address # dearly shown marked on the deck for each inspection ea plane o the Revised on 5/21/2009 RECEIVED ROOF ASSEMBLIES AND ROOFTOP STRUCTURES JUN 2 4 - 014 .� Miami Shores Village APPROVED BY DATE Master Permit No. ZONING DEPT Florida Building Code Editigrr2Q' 0:PT High -Velocity Hurricane Zone Uniform Perm Application Form. Section A (General Infort �' id- T TO COMPLIANCE WITH ALL FEDERAL S TrA-15-roiCNISITY RULES AND REGULATIONS 1 ROOF CATEGORY Low Slope 0 Mechanically Fastened Tile 'Mortar/ } 0 Asphaltic Shingles 0 Metal Panel/Shingles 0 Wood S 0 Prescriptive BUR-RAS 150 ROOF TYPE 0 New Roof / Reroofing 0 Recovering ❑ Repair ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep aloped Roof Area (SF) Total (SF) (00 5300 Contractor's Name q I u ftTt L) I` OO F j It3 G- �1 ) �/ Job Address - 10t w..) '1 E. 5 AN) . fro � t S , t ` . 331 �8 Section B (Roof Plan) 544O Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and Iocatip , of parapets. • . • . • .. .... . . . . . .. . • .... .... .. . • • • . • • • . . .. • • •. : .-. • • • -44 • • • • • 4 4 I .. .. .. � . 15.34 2010 FLORIDA BUILDING CODE — BUILDING 02 q c S,h A v.4. Q c� iGtoi.l sko,� �� Ft 3315 ••.• • • •• •••• • • • •••• • • • ••• •• • • • tom' • • •• ••• • • .�• • r •• • • • ••• • • • 5"LoPE _ 53 5 z , R. = 3 %,z s /0i2ii Section C Miami -Dade county HVHZ Electronic Roof Permit Form Section C Page (Low Slope Roof Systems) ir? -spi a roof assenzbiyr.amp-::-.,.ant,s- no.? rer4E.:17Fici, n::: mI ij tet: Top Ply: ROOF SYSTEM MANUFACTURER Product Approval (NOA): 31MSystem Type: Wind Uplift Pressures, From RAS 128 or Sealed Calculations: (P1) Field: psf (P2) Perimeters: psf (P3) Comers: Maximum Design Pressure From NOA: 108.0 psf Surfacing: SINGLE PLY MEMBRANE: Single Ply IVIanufacturer / Type: psf Single Ply Sheet VVidth: Roof Slope: " :12 Roof PAean Height 1Z ft. CI Parapet Walls: No 0 Yes Parapet wall Height Deck Type: Support Spacing: Alternate Deck Type: Existing Roof: Fire Barrier Vapor Barri Plywood— oIc No. of Single Ply 1/2 sheets: ft. Single Ply Membrane Fastening / Bonding Material: El FASTENER SPACING FOR BASESHEET ATTACHMENT 0 SINGLE PLY MEMBRANE ATTACHMENT 1/2 Sheet Width: Anchor Sheet Anchor Sheet Fastener / Bonding Material: 0211.11 InsulationBase Layer Sae & Thickness: Insulation Base Layer Fastener / Bonding Material: 1311.11111 Insulation Top Layer Size & Thickness: :311111111 Insulation Top Layer Fastener / Bonding Material: 1:1111 Base Sheet( ) 5 lb. 1 ply Base Sheet Fastener / Bonding Material: & No. of Ply(s): 1-1/4ring shank nails w/ tin caps • • rows olc - olc 3. Forney: . • • 1_ Field: 9 olc @ Laps 8, 2. Perimeter: 0/0 1-aPs & 3. Comer ' o/c @ Laps & NUMBER OF FASTENERS PER INSULATION BOARD: rows rows olc 1. Field: 1 j 2. Perimeter: Insulation Fastener Type : Wood Nailer Fastener Type and Spacin EDGE & COPING METAL SIZES: —Galvanized Nretal•-• • Edge Metal Material: Edge Sizei• Hook Strip Size: Edge Metal Attachment —3" face 24-ga.- -SELECT EDGE METAL HOOK STRIP SIZE — Coping Material: --SELECT COPING METAL SIZE OR THICKNESS _SELECT COPING METAL HOOK STRIP SIZE — . • • • • • • • • • • . Coping Size: Hook Strip Giro: Parapet Coping Metal Attachment • • —SELECT PARAPET WALL COPING MATERIAL — • • . Edge Nailable Deck Miami -Dade County HVIIZ Electronic Roof Permit Form Illustrate Components Noted and Details as Applicable: Top Ply trterphes \.4 Base Sheet %' -q Roof Deck a ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High -Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steep Sloped Roof System) Roof System Manufacturer: EN cs-iV1' Notice of Acceptance Number: .10 1210 2-0' I Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations) ` P2: (o $' I P3: — t p °' 15.36 Steep Sloped Roof System Description Deck Type: Roof pe 12` Ridge Ve_nialitigp? Mean Roof Height: Wo00 Type Underlayment .cse., 1.4- "" v • 041600 • • • • • Insulation: . f ! ..• ..... • • •• Fire BaRier: 1 (1 ' 0000 �. • ... a.• ! ---.._ • •�• • • • oi �1p+1 CS'Gd _ r.l o Fastener Type & Spacing: � i o�..`�s. t,� 2G + • • 3 m e?• Ly: oAp a•:Pr N--t+ a •: Adhesive Type: Type Cap Sheet Roof Covering: Type & Size Drip Edge: kw A FL • • PLA-n-ra-n o { q Q 2010 FLORIDA BUILDING CODE — BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 2010 High -Velocity Hurricane Zone Unlfotm Permit Application Form. Section E (Tile Calcines#ions For Moment based tile systems, choose either Method 1 or 2 Compare the values for Me with the values from Mr. If the Mr values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptabk. }fMeethod 1 "Moment Based Tile Calculations RAS 127" �D• /_ 1 x ivd "1 • =�v�) - Mg: 1 lit MA '3 Product Approval Mt- `pl: 'L'19_ its9 11444 ��•' v. AQ� _ (Qb� - mg: - M`t2 ?? Product Approval Mr fP2. -2.1 3 Product Approval Mi. •°.# (P� 100�� x bo' = !) - = Mr3 • • • • • • • • Method 2 "Simplified TileCalculations Per Table Moe • • • • Product Approval Mf • • • ^�U"` • Moment of Resistance (Mr) From Table Blow I ^`fl" required Moment Resistance* I — i • • r • • • Mr • • • ••••• �. ao' • �• aAAean Roof YelBpl'• 15 l 20' 25' • • • • • Root gtto'. 38 2 i 39.7 � 422 •• • •• 34A 36.5 r_._..__&2 38.0 ; 37A 39.8 • • • • • • fir • 322 4 __I 373 • • • 32.2 33 8 35.1 • 4:1¢ -- — 28.3031.8 1 32.8 349 • • • •• ?B.4 •••1• • ••01 •S i2 i 7:12 24A 'Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for r with the values for Fr. lithe F' values arc greater than or equal to the Fr values, for each area of the roof, then the the attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T' Product Approval r Product Approval Fr Product Approval F' 25.9 27.1 xcos8 =F.t xL = xw:= -) W: (Pt: 0,21 x L = xw:_ )-W: x cosB =Fr2 x cos =Fri xL - xw:= 1-W: �p3; - Where to Quin intern »lion Where to find Description tSyind2i Design p PI or P2 or Pg n S 127 Table l or by an engineering analysis prepared by PEbased on ASCE7 I H 4 lob Site Mean Roof Height Roof Slope i 8_ ,_ lob Site .- - -{ ..Froduct Approval Aerodynamic Multiplier . , .------ M Product Approval Restoring Moment due to t7raviry g 1-_ ----- AttadUnent ReSistarxc a Mf i Product Approval Required Moment Resistance : MeCalculated -- F' 1 Product Approval Minimum Attachment Resistance i _,- Requited Uplift Resista nce Fr I Calculated - _ Average Tile Weight I; W Product Approval L = length Approval Tile Dimensions I W = width All calculations must be submitted to the building official at the time of ptxtmt application. 15.3T 2010 FLORIDA BUILDING CODE — BUILDING MIAMI�-.� DADS Yr -NWit. DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCE'S (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 wtitw.miamidadr.kovleronomv GAF 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials, The documentation submitted has been reviewed and accepted by Miami Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-DadeeCounty) CountyuProducte the right to have this trol Section (In Miami Dade County) and/or the AHJ (in areas other �erlf thisMiami roduct or material to perform in the accepted product or material tested for quality assurance Pulp P manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within eir llction. RER reserves to revokethis acceptance, if it is determined by Miami -Dade County Product ControSection thatthis product material fails to meet the requirements of the applicable building code, This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built -Up Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed andIheV bias beea rw Chang:..... in the applicable building code negatively affecting the performance of this product. .. • TERMINATION of this NOA will occur after the expiration date or if there has been a rsY1on or change in the...• .. . materials, use, and/or manufacture of the product or process. Misuse of this NOA as an enamel/lent ofY product, • for sales, advertising or any other purposes shall automatically terminate this NOA. Failure tvee9)1y withppy.seethoN; • •. of this NOA shall be cause for termination and removal of NOA. • . ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, F1rorida, •and fg1lowwd by tre • portion of the NOA is din laYed,then it shadbe dope . be displayed in advertising literature. If any P • .... p • • • • expiration date may in its entirety. • • . • INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA No, 07-1219,09 consists of pages 1 through 17. The submitted documentation was reviewed by Juan E. Collao, R.A. MIAt4$DADQ4COUNTY APPRED NOA No.: 13-0424.09 Expiration Date; 11/04/14 Approval Date: 10/31/13 Page 1 of 17 ROOFING SYSTEM APPROVAL Category: Sub-Cateeorv: Material: Deck Type: Maximum Desil:a Pressure: Roofing BUR Fiberglass Wood -75 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Dimensions GAFGLAS®#75 Base Sheet GAFGLAS® #80 Ultima Base Sheet GAFGLAS® FlexPly"u 6 GAFGLAS® Ply 4 GAFGLAS® Mineral Surfaced Cap Sheet GAFGLAS® EnergyCap BUR Mineral Surface Cap Sheet GAFGLAS® Stratavent® Eliminator Perforated Venting Base Sheet GAFGLAS® Stratavent® Eliminator Nailable Venting Base Sheet Ruberoid® SBS Heat - Weld' Smooth Ruberoid® SBS Heat - Weld' 25 Ruberoid® 20 39.37" (1 meter) Wide 39,37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39,37" (1 meter) Wide 39,3T' (1 meter) wide 39.37" (1 meter) Wide 39,37" (1 meter) Wide 39.37" (1 meter) Wide 39,37" (1 meter) Wide 39.37" (l meter) Wide Test Specification ASTM D 4601 ASTM D 4601 ASTM D 2178 ASTM D 2178 ASTM D 3909 ASTM D3909 ASTM D 4897 ASTM D 4897 ASTM D 6164 ASTM D 6164' ASTM D 6163 Product Description Type II asphalt impregnated and coated glass mat base sheet. Type II asphalt impregnated and coated, fiberglass base sheet. Type VI asphalt impregnated glass felt with asphalt coating. Type IV asphalt impregnated glass felt with asphalt coating. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules with factory applied EnergyCote' ••.. •Fiberglass base sheet Coati nni oth sides+►vith asphalt. Surfaced on the bottom &ide wjttr;nin eral granules embedded in aspiiiiitt'; oating' ith•facto►y perforations. • • • • .. • •••• . • A nailable, fiberglass base; !t; ;t impregnatea and coated on both sides with,agatOt• Surfa4CdOn the bottom side with mineral.grai14es emee�ded in • • . • asphaltic coating. • • Non -Woven Polyester rnat paned wifh polymer- • modified asphalt and smooth surfaced : Non -Woven Polyester mat coated with polymer - modified asphalt and smooth surfaced. SBS modified asphalt base sheet reinforce with a glass fiber mat. • • • • . . .• NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 1 0/31 /13 Page 2 of 17 TRADE NAMES OF PRODUCTS MANUFACTURED OR E 1 LABELED BY APPLICANT:TAB Test Product Product Dimensions Specification Description Ruberoid®Mop Smooth 39,37" (1 meter) ASTM D 6164 modified asphalt_ and smooth surfaced.on-woven polyester mat coated with polymer - wide wide 5, 55 gallons Proprietary Low VOC, water based fire barrier coating, 350 sq ft, roll ASTM D 226 Non -Asphaltic Fiberglass -Based Underlayment. FireOut Fire Barrier Coating VersaShield® Fire Resistant Roof Deck Protection Topcoat® Surface Seal 5 gallons ASTM 1? 6083 Solvent based sprayable thermoplastic rubber sealant designed to protect and restore aged roof SB surfaces and to increase a roofs reflectivity, APPROVED INSULATIONS: Product Name EnergyGuare Polyiso Insulation EnergyGuare RA Polyiso Insulation EnergyGuarr RN Polyiso Insulation EnergyGuard'" Perlite Roof Insulation EnergyGuardm Perlite Recover Board EnergyGuardd RA Composite Polyiso Insulation Securock® Gypsum -Fiber Roof Board Structodekie High Density Fiber Board Polyisocyanurate foam insulation polyisoeyanurate foam insulation Polyisocyanurate foam insulation Perlite insulation board. Perlite recover board Eolyisocyanurate foam insulation with high density fiberboard or Perrnalite perlite insulation Gypsum roof board High density fiber board TABLE 2 Product Description Manufacturer (With Current NOA) GAF • . • .. . GAF GAF GAF GAF •... • . GAP ••• ••.. • . . .. . • • i-t9G Co>{3oratipn • • •• 13140 f iilge Fibet$pyrd, Inc.. • •• •• ••.. • . . • • . . .. • ••.• • • NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 3 of 17 APPROVED FASTENERS: Fastener Number 1. 2. 3. 4. 5. 6. Product Name Drill-Tec'u #12 Fastener Drill -Teem #14 Fastener Drip-Tec"� XHD Fastener Drill -Teem ASAP 3S Drill -Tee 3" Steel Plate Drill -Tee" 3" Standard Steel Plate 7. Drill-Tec AccuTrae Flat Plate 8. Dri11-Tec'" AceuTrae® Recessed Plate TABLE 3 Product Desc ri tion Insulation fastener for steel, wood & concrete decks, Insulation fastener for steel, wood & concrete decks. Carbon steel extra heavy duty fastener used in steel decks. Drill -Tee "' #12 Fastener with Drill-TeeT"( 3" Standard Steel Plate Round gaivalume stress plate used with Drill-Tec" fasteners. Round galvalume plated steel stress plate with reinforced ribs for use with Drill -Tee Tm fasteners. AZ -SS aluminized steel plate for use with Drill -Tee" #12 Fastener, Drill -Tee #14 Fastener and Drill -Tee" #15 Fastener. Galvalume Steel plate for use with Drill-Tec" fasteners. Dimensions various various Various Various 3" round 3" round 3" square 3" square Manufacturer (With Current NOA) GAF GAF GAF GAF GAF GAF • • • .. . • •... •• ...• . . •• •• • • . • • • . . .. . GAF GAF ••.. ••.•. • ••. .• . • •• • • . . • .. ••.. • •... • • ••.. • •..... .• • • • • . . •.... •. • • •..•.. NOA No.: 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 4 of 17 Deck Type 1: Deck Description: System Type E: Wood, Non -insulated 19/37" or greater plywood or wood plank decks Base sheet mechanically fastened. All General and System Limitations shall apply. Fire°item Fire Barrier Coating, VersaShield® Fire Resistant Roof Deck Protection or Securockh Gypsum Fiber Roof Board. GAFGLAS® #80 Ultima"' Base Sheet, Stratavente Eliminator"' Nailable Venting Base Sheet, Ruberoid® 20, Ruberoid® SBS Heat WeldT"' Smooth or Ruberoid® SBS Heat - Weld."'" 25 base sheet mechanically fastened to deck as described below; GAFGLAS® Ply 4, GAFGLAS® F1exPlyT"s 6, GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c, at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® FlexPlym 6, GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill -Teem, #12 Fastener or Drill-TeCT"' #14 and Drill- TecT"' 3" Steel Plate, Drill-TecT"' AceuTrac® Flat Plate or Drill-TecTM AccuTrac® Recessed Plate 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet, (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Flex PIyT"' 6, GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field, (Maximum Design Pressure 52.3 psf, See General Limitation #7) ; • .... • GAFGLAS® #80 UltimaTM Base Sheet, Ruberoid®20, Ruberoid month, Dsse sheet ...... steel ate at a '. attached to deck with approved PA" annular ring shank nails and iitua 3" • • • . f 9" at the4" lap and in two rows staggered•w►t i a fastener spacing of • • • • See General Limitation #" • • •• • • Maxim. um Design �'ressure —60 psf ... . Fire Barrier: (optional) Base sheet; Fastening Options: fastener spacing o o.c.. • • • 9" o.c. in the center of the membrane. • GAFGLAS® #75 Base Sheet or any of above base sheets attached to 'deck witb r1-TecTs' • • • • • #12 Fastener or Drill-TecT"' #14 Fastener and Drill-TecTh' 3" Sts dl'Playe, Drill-TyeT", • • AccuTrac Flat Plate or DriH-TecT"t AccuTrac® Recessed Plate i2" o.e in 4 rows. One • • . • l 9'o c.ih the . • row is in the 2" side lap, The other rows are equally spaced appioxurtate Y • • • • • field of the sheet. • •.•• (Maximum Design Pressure —60 psi; See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and 3" ered inverted Drill-Tec", insulation plates at a fastener spacing of 9" ex. at the 4" lap stagg in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) NOA No.:13-0424.09 Explratiof Date; 11/04/14 Approval Date; 10/31/13 Page 15 of 17 GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill-TecTM #12 Fastener or Drill-TecTM #14 Fastener and Drill -Teen" 3" Steel Plate, Drill -Teen"' AccuTrac® Flat Plate or Drill-Tec'r"' McuTrac® Recessed Plate 8" o.c.lin 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet- i (Maximum Design Pressure —75 psf, See General Limitation #7) 1 ply Sheet: One or more plies of GAFGLASe Ply 4 or GAFGLAS® #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet it GAFGLAS® EnergyCapT" BUR. Mineral Surfaced Cap Sheet adhered in a full illoppingof approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions 1. Gravel or slag applied at 4001bs./sq. and 3001bsisq. respectively in a flood coat of approved asphalt at 601bs,/sq, 2. Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. Maximum Design Pressure: See Fastening Above • • • • • •• • • •..•.• •••• • • •••• • • •• •. • . • • • • • • • • •. • •.•• • • •••• •..••• • • . •• .• • •• • •• • •• •••• • •••. • • • •••• • • • • • • • •••.• • 000000 00000• • NOA No,; 13-0424.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 16 of 17 • WOOD DECK SYSTEM LIMITATIONS; 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® Flex PIyTM 6 when base or anchor sheet. 2. Minimum '4" Dens DeckT"' Roof Board or 'A" Type X gypsum board is acceptable wood deck. used as a mechanically fastened to be installed directly over the GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Rooting Materials Directory for fire ratings of this product 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Productn Control Approval guidelines. All other layers shall be adhered in a full mopping of fieproveddasphalt applied of the top within EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using fastening pa r 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum.foam 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbonst in three rows, one at each sidelap and one down the center of the sheet allowing12' in each ribbon to allow cross vencontinuous area of ventilatien. tilation. Asphalt ng of the strips is not acceptable. A 6 break shall be placedeveryshall be application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems limited to a maximum design pressure of -45 psf, value of 275 5. Fastener spacing for insulation attachment is based on TAS 105.If a Minimum the fastener valaracteristic ue, as,)field-tested, lbt, as below tested in compliance with Testing Application Standard 2751bf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the required, as determined by the Building Official, atevispd faster►F facing, fastener resistance be less than that stered • . prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Anfit ct, or efa Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal restssfanFlb Glue • • taken from Testing Application Standards TAS 105 and calculations in compliance with l aiding - pp • Standard RAS II 7. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements' bf these' areas. Fastener. err. • Standard RAS 1 h7. Calculations prepared, signed densities shall be increased for both insulation and base sheet as calculated in complia„ RoofO Pp " • and sealed by a Florida registo•professlonal Engineer,• this limitation is spec�idally xefcrl'ed within. Registered Architect, or Registered Roof Consultant (When this NOA, General Limitation #9 will not be applicable, sh acx►folmii 8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination d• esigns al Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (Le. field, perimeters, and corners). Neither rational analysis, nor extrvolationshall be ermthisted limos for eis nhanced pfastening at enhanced pressure zones (Le. perimeters, extended corners and corners). clly referred within this NOA, General Limitation #7 will not be applicable.) 10. All roducts listed herein shall have a quality assurance audit in accordance with the Florida Building Code and P Rule 9N-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE APPROVED NOA No : 13-0424.09 Expiration Date; 11/04/14 Approval Date; 10/31/13 Page 17 of 17 ase Y may be solid mo^ �Ruheto_ • pry of base sheet Y �� m� he hot mopped or arzcharu�uy aub��fi►'i°��� Mlirraat.•�°� Cap S"`� '•hot aeP itrRashi initiated. all CaF • et • rpropostteP� a00F covEtt1KG 14ATERMA'S (T VO kOOF1NG SYSTEMS (TGFlJ)�Conuntted tale cooppasite, phenolic. 'rw y,rtrh.nz cUmposlte. wood fi0��ocyamt Type GI'GAFG- Ply 4'or• PlyTAWS thickness. Pti Sneer.: Twee of more ids o'. hot mopped. ; Z Surfacing: GraoeL yers perdu. wood fir, glass 2. trcci: Insulation 2 O tional): One or l atlu co o ostt� .Gass uriatioo (Optional): Pe arauaa comp fiber, ne isoc composite, wood fiber%tsocY urethane comP°uLe' f GtAS Py► �i' or'GAFGfJIS.PIY tint kne s. to layers Type Gi'G • Ply Sheet Truce of MOM Y � Mineral Surfaced Cap Sheet'. DC,p Shce4 One LaYef Type G3 ' �tfna peke, wood . MCp or more layers pe , .Rh perhu/ - ..�71a' wood noe4 �-+ 0`dc lion (Optional): urethane. /SERIALS 'CORP ::.' • utilizes as as is NC o f Type G2 ' pl 4 of i W 2 itei WhY+I ` ed Base Sleet.' may be t 6 `last Sheer. One (aye! of Type G1 "CAMAS Y ROW Type ,r - of the blowing Uessi Georgia-Pacific tic ply Sheet One or more lay` Surfaced Cap f. e w Type hoard or 1J4 is thick (min) noncombustible 6'. layer of Type (r3'WFG1.AS Mum tntrlc (alit(` end be used in any existinggroofi system is Cap Sheet 4 lay lidinC fur tuedtarte. Me far use over board ate onset b � below the �w(tsory plywood JOinis, � 63. azut�boa�d � Fur of the ��� One or mac - �'( or i et wlTtt tiOT ROpf1NG ASPHALT is a �nnc One or more >ay�bid Mop'•(i�� 9 Amato fo FELT SYS S sheet i ber t y ee� .base Pty r of 'Ruberoid Torch Plus' (granule), ' ' �nau for Type 61 asFl>;it glassroO �u�ia�dirar.� below. base 'Rulxroitl Mop �� Mineral yrria�'GaP met!' � nWPPrad+• naiiablt � SVatetrent i P�df�o a) to Gamism P�'ta' tlabk deck( � ompostte. woad • • • paon Type G2 asphalt weent errt fly for n.ttabte dt ma sheet rGifGLAS psubstituted for thickness.Two of {yp'e 62 of TYPO, . 'GItFGtAS PlY 67 as the sale Sheet re o 041 ? of TYPO, or g rle)• pass e (roof COVERING MATERIALS (r£1R) ROOMS SYSTEMS (TGFU)—Continued kGQ� • pot- foam tit' or 'r°tyivam t arrati ftf•Is' lr'F y-1 Spcc� with ` 7 3a3`. 1 ia• One applications 'Gacotlzx tra-7050'. applied at 1 base Coat 0tt or rtag-di PP pans. applied 1-1/4 gaVsq/apptrcapan at/SS/aPPucaaoa or thtet aPPhca 1 g;► jsq to �Su -32 dry y mitsl- ez Uk65' Sevres (wrrous colors), aPPt' eo dry mils). Incline i/2 Sso p „r�th 'patyfaar�► 251' at 'Patytoam :dr: NCFoam:'Poty-Is°' or "?oty- 5 cant• applied ,t 1 t 1airs 1oian. One or two applita[i°nS 'Garottes UB-70.0'. ei o s'. applied UB-7 gal/so/application1 tdV�apPlrtrti0n °r three aPPu 19s�is4 (15 16-32.ary'6ta�elofte�r lyvacr Series Various colon), applied :uttan9= 2 By mils).Who.: oam 251' or `Polyroam ra. . 'Pot 1s°' or'Poty-lso Special with ' Yf �oam: Y- . (10 an was). lase Coal: 'G;coStt S-i000", applied at 1 g t/ q (10 Mt roils. cc5-1000'. appallwaive;1 cc 255i' or'P0dyfoam '. any mils. a: hC 9: We -Shield 700Inaiot 2-1/2 �'Potytoatn 275', aM thickness.gaUs9 (14 dry mils). ase Coal •Gacoftts �00 series (various cola 1-1/2 gal/sq (1 urfaciag; 'G:coltez `," ry mils). ft1306 (M) pethte� ',. 2 in. One urethane posit to composi>� �r Pty M composite, +�+ i <' or.�t/i5 Pty a Wen Type 61 "GAM Pty _ Pty ShcrL Twa or more Sulfated VP . •GAfGtAS Mineral Cap Sheet: One layer Type ma 1/2 hot moPP��u e. ah t 0nt or Pia layer Isotherm , • lass Any W. Classified gravel surfaced CiaSS A asphalt lnsulat3sa: Liable: 1 Sheet tional): Red rosin paper, nailed Base Sh�C (may p Sto deck. heet m� of Type 62 �� ' or Gl1fGl� Ply naileb)- layers of Type G1'GAFGtAS Ply Ply Sheri One or more (aye Surfaced Cap Sheet'. G-3 -CAWS Mineral V_ - One .�..nr of Type �w Crii-wCs! 3 Cap Sheet: CiAtAs 11?5 Base Sheet". f{,LJA5 My board - One ucr.'a�' ov this may yd°Oe' t� resulting des- Tne joints in T Dods C-15%2 one or more wets P�'-9 peke/urethane comps P�OIiG yssificat rd. (15/32 is min) io_ with the }coos rn the instite iso anurate composite. 5 etha ;um baud and apart of theent roof sy' it must be Pia 1.0 in min (offset from a layers �" Tl of t Essio°th )• Base . • ... and of M may s e wed with a y> perforate' or 'GAFGIAS Strad nt a phdrt>�� • iAFG tedto be mopped... {Tyra g down. base 5 Base Sh urethane c .I AS Stn L Plat 4' or Ply Sheet (Optional): •tiugeroW Torch' gam) or llt glass fOtt°+trirKj systems. or mechanically Membrane: One Or more toyed 'itNbe�aid Wes(rarmoth Of pt to the per, spot mopped id Torch Plus!` (g , . . . . in the Class A, B of T � asphalt glass filuc isocyanurate, urethanAna e. Cap Shen: m 2 TC wood aer� C-15/32 insuLation (Optional): 0� � mdcE.laY� ur the Cass lea 3 4/2 ppuce Ddetr. PERMAl1TEw or any i (Optional): One pai34/ PeN insulation. Glass Wood f�erlSs°cyamra ot.Po�ajp' may be used for flashing to any � � fbe4 _ back: t 15J32 - - of more Wye p� . la pine( ins this inttuoes 'CAMP fi lation anurtio uredtaat, Pe��. to eke, wood arty Classified p� alternates for gravel to any of the urethane Upositer Sit , o�'W1EGtA5 'stone of stag of Type ' listed. 'lade to be included - thickness. Two or more tayets Gi �l cement following Class 8 t systems listed �� A 8 or C systems Ply o Type � GAFGLAS Mineral. � 3-1/2 fiber building witssare tmnsit1c over C-1,;32 or NC.. Ply Sheep `" Cap . mopped. in gypsum beard the ating. The the Mowing 1/2�m hoard is Cap Sheet:wood hot (e aaf dversely effectnab' 1 over list of 1J2 in. min gyps'' Z. 0 C-15/32 One of more layers P it►ation a aver et eon decks. Insulation (Optional): prat composite, able alternate forp rte hoard _ 4 in.iso nara urethane. isO�Y �pc p ss of potystyisar'rtudaa°a board betS+ecn lane 3/ rrtt/PErtite) is a fiber. c7@ �' good r atw�ta rein roan Pifer IP Jt6sin eter following B or C urethane to 1p itlat>iLe fill board in the faU°enn4 Class ti iodates& y Gt. GZ of (smooth o f 9ramdeir rm Lk' and 'Gy1FTEMP Base Sheet Two or more layers d T .or nth or gram+ °t "WOW Tapered = one or mote layers of'RubeTidle) ' nth far be suliStitite yatror to insulation its any of the : ban d TorchPn ((granule). -Wood eds tatutte)_ hoc aroppt�- 'RuberoR' GLAS Mineral Surfaced Gap ` Class �' $ and G. fats or modified bimtntir Cap S> pass C .�yt, far use �'► Mink and glass ; I� � wood Class L Peck: C t5/ Lj One ac mote u� any 92 fiber. • MIAMI DADS COUNTY BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 Entegra Roof Tile, Inc. 1289 NE 9th Ave Okeechobee, FL. 34972 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Plantation Roof Tile .... LABELING: Each unit shall bear a permanent label with the manufacturer's name or l+ogoacjty, st•ate arlJ following statement: "Miami -Dade County Product Control Approved", unless otherwis8 Noted hersitf ; •. RENEWAL of this NOA shall be considered after a renewal application has been file4 i .there has lleen no change in the applicable building code negatively affecting the performance of this prodtlgt• .. •. • . •• TERMINATION of this NOA will occur after the expiration date or if there has been a Fe iision or chh$ge in tht: • •. materials, use, and/or manufacture of the product or process. Misuse of this NOA as anatolgrsemerit of any product, for sales, advertising or any other purposes shall automatically terminate this NA9.. Failure to.comply with any section of this NOA shall be cause for termination and removal of NOA. : • ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed3 ..: the expiration date may be displayed in advertising literature. If any portion of the NOA is displaypil: then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. • • • • • This revises NOA No. 10-0804.15 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. MPAMI.DADE COUNTY APPROVED NOA No.: 10-1202.01 Expiration Date: 12/08/15 Approval Date: 12/30/10 Page 1 of 5 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE: This renews a roofing system using Entegra "Plantation" concrete roof tile, as manufactured for Entegra Roof Tile, Inc. in Okeechobee, FL as described in Section 2 of this Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable Building Code, does not exceed the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Test Product Applicant Dimensions Specifications Description Plantation Tile Length: 161/2" Flat concrete roof tile for direct deck or Width: 13" TAS 112 batten nail -on. Trim Pieces Length: varies Accessory trim, concrete roof pieces for Width: varies TAS 112 use at hips, rakes ridges and valley Thickness: varies terminations 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. .... 3.2 For mortar or adhesive set tile applications, a static field uplift test in acoordance.witli• • TAS 106 may required, refer to applicable building code. • • • • • • • • • 3.3 Applicant shall retain the services of a Miami -Dade County Certified Lbbratory•tb • • perform quarterly test in accordance with TAS 112, appendix 'A'. Nch testing Ahaf be submitted to the Building Code Compliance Office for review.•• • • 3.4 Minimum underlayment shall be in compliance with the applicable.R ug .... • • Applications Standards listed section 4.1 herein. • • • • • • • • 3.5 30/90 hot mopped underlayment applications may be installed perpriellcifar to the roof slope unless stated otherwise by the underlayment material manufabturers' publitbed:. • . . literature. • ••• •• 3.6 This acceptance is for wood deck applications. Minimum deck requirements sh the • in • compliance with applicable building code. 4. INSTALLATION: 4.1 Entegra Roof Tile, Inc.'s Plantation Flat Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,119, & 120 4.2 Data For Attachment Calculations MIAMIDADE COUNTY APPROVED NOA No.: 10-1202.01 Expiration Date: 12/08/15 Approval Date: 12/30/10 Page 2 of 5 Table 1: Average Weight (W) and Dimensions (1 x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Plantation Tile 11.6 1.375 1.08 Table 2: Aerodynamic Multipliers - a, (ft3) Tile X (ft3) X (ft3) Profile Batten Application Direct Deck Application Plantation Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf) Tile 2"• 12" 3"• 12" 4"• 12" 5"• 12" 6"• 12" Greater than Profile 7": 12" Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Deck Deck Deck Deck Deck Deck Plantation 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Tile 4 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) For Nail -On Systems Tile Profile .Fastener Type Direct Deck (Min 15/32" plywood) Direct Deck (Min. 19/32" plywood) Battens Plantation Tile 2-10d Ring Shank Nails 30.9 38.1 •17.2•. 1-10d Smooth or Screw Shank Nail 7.3 9.8%•.••: �• ; • • • 2-10d Smooth or Screw Shank Nails 14.0 18.8+ ' •••• •1 7.4 •• • 18.7• #8 Screw 30.8 30.8 ••••• 2 #8 Screw 51.7 51.! -•••• 2d. 1-10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 : • :• 24.. • . 1-10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.Q ••• •• • :12-1.' •••• 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 •34'8 2-10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2-10d Ring Shank Nails' 50.3 65.5 48.3 1 Installation with a 4" tile headlap and fasteners are located a minimum of 2/2" from the head of tile. MIAMIDADE COUNTY APPROVED NOA No.: 10-1202.01 Expiration Date: 12/08/15 Approval Date: 12/30/10 Page 3 of 5 • .• . • • .• . Table 5: Attachment Resistance Expressed as a Moment Mf (ft-Ibf) For Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Adhesive 31.33 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weights per patty 13.9 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf) For Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile PolyProTM 118.94 PolyProTM 40.4' 4 Large paddy placement of 45 grams of PolyProTM 5 Medium paddy placement of 24 grams of PolyProTM. Table 7: Attachment Resistance Expressed as a Moment - Mr(ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance See specific mortar manufacturer's Notice of Acceptance. 5. LABELING 5.1 All tiles shall bear .the imprint or identifiable marking of the manufacturer's nan of %go as seen below or following statement: "Miami -Dade County Product Control Approved". 5.2 Entegra Roof Tile, Inc.'s Plantation Roof Tile bears the following. jlitigs: War `'E" • USA, "E", Entegra "E", where the E is a stylized logo. 6. BUILDING PERMIT REQUIREMENTS .... .. . • . . .. . ..•• • •. 6.1 Application for building permit shall be accompanied by copies of thp,jlowing: • .; . 6.1.1 This Notice of Acceptance. • 6.1.2 Any other documents required by the Building Official or applicabre Building. Code in order to properly evaluate the installation of this system. • • • 7. MANUFACTURING LOCATIONS 7.1 Okeechobee, FL MIAMIDADE COUNTY APPROVED • • • • . .. . .... • . . .... NOA No.: 10-1202.01 Expiration Date: 12/08/15 Approval Date: 12/30/10 Page 4 of 5 PROFILE DRAWING PLANTATION FLAT CONCRETE TILE END OF THIS ACCEPTANCE MIAMIDADE COUNTY APPROVED ...• . . . .... . . . . .. . .... . . . .. • . . . . .... .. . • . . .. . .... • .. .. . .... .... ..• . . • .. • • • • • •• • • • • •. ..• •••• • • • NOA No.: 10-1202.01 Expiration Date: 12/08/15 Approval Date: 12/30/10 Page 5 of 5 MAMI DE COUNTY DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) TAMKO Building Products, Inc. P.O. Box 1404 220 West 4th Street Joplin, MO 64801 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade .County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Tamko Uuderlayments MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175.2474 T (786)315-2590 F (786) 31525-99 www.m iamidade.sov/sera • . .... • .• .. . •... LABELING: Each unit shall bear a permanent label with the manufacturer's name.e s Logo, citJ%,.sthtd and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted' herein. • •... •.. . . •. . • RENEWAL of this NOA shall be considered after a renewal application has been fiUed&id there, . been no change in the applicable building code negatively affecting the per formance4ih' s prod►:at, TERMINATION of this NOA will occur after the expiration date or if there has been•a revision o� change in the materials, use, and/or manufacture of the product or process. Misuse Qf thi NOAes'ati • endorsement of any product, for sales, advertising or any other purposes shall autori'1atitatly terminate, this NOA. Failure to comply with any section of this NOA shall be cause for termination and reracival of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 08-1008.04 and consists of pages 1 through 6. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 12-0406.07 Expiration Date: 07/05/17 Approval Date: 06/21/12 Page 1 of 6 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS SCOPE: This approves Tamko Underlayments, as described in this Notice of Acceptance; designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product pimensions TW Metal and Tile 39 %" wide Underlayment Manufacturing Location #1 Moisture Guard Plus Manufacturing Location #1 TW Underlayment Manufacturing Location #2 Awaflex Manufacturing Location #1 39-W' wide 39-34" wide 9-3" wide Awaplan 170"" 39-%" wide Manufacturing Location #1 p.. :.1 I .CRC) APPROVED Teat Specification TAS 103 ASTM D 1970 ASTM D 1970 ASTM D 1970 TAS 104 TAS 104 Product pescdiption Flexible, self -adhering rubberized asphalt sheet material with a polymer surface for use as an underlayment in sloped roof assemblies. May be used as a secondary water barrier for full -roof coverage or, when cut into appropriate width strips, for taping sheathing joints. Flexible, self -adhering rubberized asphalt sheet material with a granular surface for use as an underlayment in sloped roof assemblies. May be used as a secopdeiy water barrier for full-rpofpgyerage tin; when cut into appropriate width stops, fof using sheathing joints. ' . • . Flexible, self -adhering M6 erized ASph&lt sheet material with a Rglylner surf ace o; use as an underlayment in loped roof,.:. assemblies. May be ua&Las a secondary water barrier for full -roof coverag4 ph when cut into appropriate w:dthatrips, fbr taping • . . sheathing joints. .... SBS modified cap sheet with a non- woven polyester mat saturated with asphalt, coated on both sides with SBS rubber modified asphalt and surfaced with ceramic granules. Applied in hot asphalt. A polyester reinforced SBS modified bitumen membrane surfaced with granules. Applied in hot asphalt. NOA No.: 12-0406.07 Expiration Date: 07/05/17 Approval Date: 06/21/12 Page 2 of 6 Product Dimensions Awaplan Premium"' 39-3/4" wide Manufacturing Location #1 Tamko SA Base 39 %" wide ManufacturingLocation #1 Tamko SA Cap 39 %" wide Manufacturing Location #1 EVIDENCE SUBMITTED: Test Aeepcv Exterior Research & Design, LLC Trinity i ERD PRI Asphalt Technologies, Inc. Test Saeciflcatiog TAS 104 ASTM D 1970 ASTM D 6164 Test Identifier 4448.12.01-1 4448.05.02-1 T 11090.09.08 TAP-058-02-01 TAP-058-02-02 TAP-191-02-01 TAP-192-02-01 TAP-193-02-01 TAP-207-02-0 1 REV TAP-1 85-02-0 1 REV TAP-196-02-01 MANUFACTURING LOCATION: 1. Joplin, MO 2. Columbus, KS APPROVED Product Description A polyester reinforced SBS modified bitumen membrane surfaced with granules. Applied in hot asphalt. A fiberglass -reinforced self -adhering SBS modified bitumen membrane with a polymer film on the surface and a removable treated split release film on the adhesive side. Shall only be mechanically fastened to wood deck. Direct adhesion to wood deck not permitted in the RVHZ. Do Not Remove Release Film! A dual -coated SBS-modified cap sheet with a nonwoven polyester mat surfaced with ceramic granules and a split removable release film on the adhesive side. Test Name/Renort Date TAS 103 12/19/2001 TAS 103 05/29/2002 TAS 117(B)/ TAS 114(C) 09/18/08 TAS 103 04/3 42 TAS 103 ; . • • 05729,/01. ASTM D 1970 '• ' 11411T/07. ASTM D 1970 • 11/1`./07' ASTM D 1970 .... 11 /.1.6/07 TAS 104/ ASTM D 12410/08' ASTM D 6164 • • 11 /06/08• ASTM D 1970 • • • • 01,09/08 • . . • . • • • . • . . .. . • • • • NOA No.: 12-0406.07 Expiration Date: 07/05/17 Approval Date: 06/21/12 Page 3 of 6 APPROVED ASSEMBLIES: Deck Type 1: Wood, Non -insulated "/32" or greater plywood or wood plank Anchor sheet mechanically fastened to deck, membrane adhered. One or more plies of ASTM D 226 Type II or ASTM D 2626 with a.minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved annular ringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. One or more plies of TW Metal and Tile Underlayment with a minimum 4" side lap and 6" end lap. Place the first course of membrane parallel to the save, rolling the membrane to obtain maximum contact. Remove the release liner as the membrane is applied. Vertical strapping of the roof with TW Metal and Tile Underlayment is acceptable. When used in Tile roof systems the capsheet shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps and 6" o.c. at the end laps. No nails or tin caps shall be exposed. Approved Mechanically Fastened Tile or Metal Roofing Assembly or Approved Roofing Assemblies where an ASTM D 1970 underlayment is allowed. Wood, Non -insulated 's/,s' or greater plywood or wood plank Anchor sheet mechanically fastened to deck, membrane adhered. One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved annular ringshank nails and tin caps 6" o.c, at the laps and two staggered rows 12 : b'e.'tbe field of the roll. Deck Description: System E(1): Base Sheet: Membrane: Surfacing: Deck Type 1: Deck Description: System E(2): Base Sheet: Membrane: Surfacing: Deck Type 1: Deck Description: System E(3): Base Sheet: Membrane: Surfacing: APPROVED • • .•.. • .• .. . ••.. One or more plies of Moisture Guard Plus with a minimum 34t i side lag asit1 6" end lap. Place the first course of membrane parallel to the eave, hng the • membrane to obtain maximum contact. Remove the release lio8t tt the m81flkrbpe is applied. Vertical strapping of the roof with Moisture Guard Pius is acceptable. Approved Roofing Assemblies where an ASTM D 1970 undarleya bnt is alibaved. Wood, Non -Insulated • 1942" or greater plywood or wood plank • . . . •.• . •••. Anchor sheet mechanically fastened to deck, membrane adhered. .... One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved annular ringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. One or more plies of TW Undpr lityment with a minimum 4" side lap and 6" end lap. Place the first course of membrane parallel to the save, rolling the membrane to obtain maximum contact. Remove the release liner as the membrane is applied. Vertical strapping of the roof with TW Underlayment is acceptable. Approved Roofing Assemblies where an ASTM D 1970 underlayment Is allowed. NOA No.: 12-0406.07 Expiration Date: 07/05/17 Approval Date: 06/21/12 Page 4 of 6 Deck Type 1: Deck Description: System E(4): Base Sheet: Membrane: Surfacing: Deck Type 1: Deck Description: System E(5): Base Sheet: Membrane: Surfacing: GEL . su - • T, 16) APPROVED Wood, Non -insulated 19/32" or greater plywood or wood plank Anchor sheet mechanically fastened to deck, membrane adhered. One or more plies of ASTM D 226 Type Il or ASTM D 2626 with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved annular ringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. One or more plies of Awaflex, Awaplan 170 or Awaplan Premium applied at a right angle (90°) to the slope of the deck adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Vertical strapping of the roof with Awaflex, Awaplan 170 or Awaplan Premium underlayments is acceptable. When used in Tile roof systems the capsheet shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 12" o.c. at the side laps and 6" o.c. at the end laps. No nails or tin caps shall be exposed. Approved Mechanically Fastened or Adhered Tile or Metal Roofing Assembly or Approved Roofing Assemblies where an TAS 104 underlayment is allowed. Wood, Non -insulated 1942" or greater plywood or wood plank Anchor sheet mechanically fastened to deck, membrane adhered. One or more plies of Tamko SA Base with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved annular ringshank nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c, the field of the ro11,al1 only be mechanically fastened to wood deck. Direct adhetion.t.owooa.deell not permitted in the HVHZ. Do Not Remove Release Film! • • . • •: • . One or more plies of Tamko SA Cap with a minimum 4" sh 1¢ and 6" end lap. Place the first course of membrane parallel to the eave, rolling tin membrane jo obtain maximum contact with base sheet. Remove the releas8.linceas the ' ..' membrane is applied. Vertical strapping of the roof with Tatnk .SA Cap : • • • underlayment Is acceptable. When used in Tile roof systems the capsheet shall be back miler tp deck, wilt; approved annular ring shank nails and tin caps at a maximum 12".o.c. at:h6' tde laps and 6" o.c. at the end laps. No nails or tin caps shall be'eatiosed .. .. .... ... • . Approved Mechanically Fastened Tile or Metal Roofing Assembly or Aphfdved Roofing Assemblies where an ASTM D 6164 membrane is allowed. NOA No.: 12-0406.07 Expiration Date: 07/05/17 Approval Date: 06/21/12 Page 5 of 6 GENERAL LIMITATIONS: 1, Fire classification is not part of this acceptance. 2, This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. Tamko Underlayments shall be installed in strict compliance with applicable Building Codes. 3. All Tamko Underlayments shall be applied to a smooth, clean and dry surface with deck free of irregularities. Deck shall be fastened in strict compliance with applicable Building Codes. 4. All Tamko Underlayments shall not be applied over an existing roof membrane as a recover system but may be applied over an approved roofing Base/Anchor sheet underlayment. 5. TW Metal and Tile Underlayment, Moisture Guard Plus, TW Underlayment, Tamko SA Base & Tamko SA CAP shall not be left exposed as a temporary roof for longer than 30 days of application. 6. Awaflex, Awaplan 170 and Awaplan Premium shall not be left exposed as a temporary roof for longer than 180 days of application. . ,:,,o: 7, The standard maximum roof pitch for Awaflex, Awaplan 170 and Awaplan Premium shall be 6:12 for flat tile installation and 6:12 profiled tiles with lugs. 8. The standard maximum roof pitch for TW Metal and Tile Underlayment and Tamko SA CAP shall be 4:12 for flat tile installation and 4:12 profiled tiles with lugs. 9. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 10. Tile storage shall be on a battened roof deck when the underlayment slope limit (See #7 & #8 above) is exceeded. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the undorlayment. 11. The Tamko Underlayments may be used with any approved roof covering Notice of Acceptance listing the Tamko Underlayment as a component part of an assembly in the Notice of Acceptance. If Tamko Underlayments are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind gplift re jive, and fire testing results. • • • • • • • • • 12. All nails in the deck shall be carefully checked for protruding heads. Re-fasteis•i y loose decking • panels. Sweep the deck thoroughly to remove any dust and debris prior to appliCatiOn? •• 13. When applying the membrane in the valley, start at the low point and work to th'e'iii'gh poldt; rolling • the membrane from the center outward in both directions. For ridge apgf gi}t3gns, ce+ntc: the • • membrane and roll from the center outward in both directions. .. •.. • ..:. 14. For the self adhered membranes roll or broom the entire membrane surface •so .as• to have 00% . • contact with the base sheet, giving special attention to overlap areas. : • : 15. Flash vent pipes, stacks, chimneys and penetrations in compliance with RV Assembly current Product Control Notice of Acceptance and applicable Building Code. 16. A11 protrusions or drains shall be initially taped with a 6" piece of approved Tamko Undeiiayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of the same Tamko Underlayment shall be applied over the taped underlayment. 17. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. • APPROVED TY END OF THIS ACCEPTANCE APPROVED NOA No.: 12-0406.07 Expiration Date: 07/05/17 Approval Date: 06/21/12 Page 6 of 6 ar, M.I.A.M1.001.13E DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORYAFFAIRS ( BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE O.A 3M Company 3111. Center Building 0220-05-E-06 St. Paul, MN. 55144-1000 SCOPE: This NOA is being issued under the applicable• rules and regulations gove documentation submitted has been reviewed and accepted by Miami -Dade be used in Miarni Dade County and other areas where allowed- by the Auth This NOA shall nat be valid after the expiration date stated below.. Th Section (In Miami Dade County) andlor the AHJ (in areas other than Mi have this: product or material tested for quality assurance purposes. if this the accepted manner, the manufacturer will incur the expense of such revoke,. modify,. or suspend the us:e of such product or material within the to revoke this acceptance, if it is, determine.d by Miarni-Dade County Prod material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to co including the High Velocity Hurricane Zone of the Florida. Building Code_ DESCRIPTION:: 3MTm 2-Component Foam Roof Tile Adhesive AII-I • ERA) MIAMI-DADE. COUNTY PRODUCT CONTROL SECTION 118.05 SW 26. Street, Room 208: Miami, Florida 33175-2474 T. (786.1315-2590. F (786)315-2599. :w1VIV.113 m i (1 ad c.g oy/o ra ing the use of construction materials_ The aunty PE:RA - Product Control Section to rity Having Jurisdiction (AHJ). Miami -Dade County Product Control mi Dade County) reserve the right to product or material fails to. perform in esting and the AHJ may immediately juris.diction. PERA reserves the right et Control Section that this product or ly with the Florida Building Code .0 LABELING: Each unit shall bear a permanent label with the manufactur- s name or logo, city, state and folio.wing statement: "Miami -Dade County Product Control Approved', unless othe ise noted herein_ •••• RENEWAL of this NOA shall be considered after a renewal application has been filed and tier oilas been rj.2.pirange • • • ••••• • in the applicable building code negatively affecting the performance of this product. • • • • • • • TERM:NATION of this NOA will occur after the expiration date or if there has been a revisiaa chang4 rifle • materials, use, andtor manufacture of the product or process. Misuse of this NOA as an endor;atnentofan?pr.crdiuct, foe • ; • sales, advertising or any other purposes shall automatically terminate this NOA._ Failure to cortaptyllth any s4edeln of this NOA shall be cause for termination and removal of NOA. • • • • •••• • • • ADVERTISEMENT: The NOA number preceded by the words, Miami -Dade County,, Fkrida, d fo1limee4 by the, expiration date may be displayed in advertising literature. If any portion of the NOA is displetclo, ten it shajLln, done. in its entirety. •••• INSPECTION: A copy of this entire NOA shall be provided to, the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request ofthe Building Official_ This renews and revises NOM 11-0124.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera, 1 * • NOA No.: 12-0218-18 Expiration Date: 05/10/17 AplocoNal Datet 05/10112. Page 1 of 7 • • • • • • • • ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Ro of tile adhesive. Materials: Polyurethane SCOPE: This approves 3Mrist 2-Component Foam Roof The Adhesive AR-I60 as manufactured by 3M Compa.ny as described in Section 2 of this Notice, of Acceptance. For the locations where the design pressure requirements, as determined ky applicable building code2 does not exceed the design pmsure vatues_pbtioectrhy..calculations-in--- comPi;ance with ROOEngApplication Standard RAS 127, foruse with approved flat,• low, and high profile roof tiles system using 2-Component Foam Roof Tile; Adhesive AH-160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product 3MTu 2-Component Foam Roof Tiie Adhesive All - I 60 Foam Dispenser RTF1000 ProPack® 30 & 100 Dimensions NIA NIA N/A Test Specifications TAS 101 Product Description Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment - - -PRODUCTS-MANUFACTURED-BY-OTHERS: - Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2-Component Foam Roof Tile Adhesive AII-160 roof tile adhesive_ MANUFACTURING LOCATION: 1. Tomball, TX. PIWSICAL PROPERTIES: Property Density Compressive. Strength Tensile. Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed ca Content Test ASTM D. 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTME 9.6 ASTM D2126 ASTM D 2856 1_6 1bs.ift.3 IS PSI Parallel to rise 12 PSI Perpendicular to ris:e 2S PSI Parallel to rise 0.08 Lbs.ffitz 3.1 Penn/Inch +OSP% Volume Change @ -40F.,. 2 weeks: +&0%. Volume Change ®158.°F., IOWA, Humidity, 2 weeks 86%. • • • • • • • • • • • • • •• • • • Results ' • • • • • • • • • • • • • • • • • • • • . . . • • . • • • •• • • • • • • • • • • • • • • • • • •• . • • • • • • • • • • • • • • • • • • NOA No. 12-0MM Expiration Date: 0S11.047 ART DM% Wilma, %SP 2 of • • • • • • • • • • • • • • • • Norte: The physical properties: listed: above are; presented as typical average values as: determined by accepted ASTM test methods and are: subject to normal manufacturing variation. EVIDENCE SUBMITTED: Test Agency Test: identifier TestName/Report Date Center for Applied Engineering ##94-060 TAS 10.1 04/08194 257818-IPA TAS 101 12/16/96 2S-7433-3 SSTD 11-93 10/25/95. 25-7438-7 SSTD 11-93 11/02//95 25-7492 SSTD 11-93 12112/95 Miles Laboratories NB:-589-631 ASTM D. 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04130/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-0621411 ASTM E 84 01/16/95. Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 Celotex Corp. Testing Services. 528:454-2-1 TAS 101 10/23./95 528:454-9-1 52:8454-10-1 520109-1 TAS 101 - 12/28/98 ._ . ___-.-- - .--....__- 520109-2 52,0109-3 520:10.9-6 520109-7 520191-1 TAS I01 03021 9, 520109-2-1 • • • • • • • •• • •••• • • •• • • ••• • LIMITATIONS: • • • 1. Fire classification is not part of this acceptance. Referto: the Prepared Roof Tile Asse rAlj�'Tor ire ra itxg �. • 2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with fiat, loa4,,&.J gh tile pra€i4es. • 3. Minimum underlayrnent shall be in compliance with the Roofing Application Standard 1' 1120. • • • • •• 4. Roof Tile manufactures. acquiring acceptance for the use of 3MTM 2-Component Foam Floof Tide Adlpesi g t1I-I- I 60 roof tile adhesive with their tile assemblies. shall test in accordance with TAS 101. ; •• • . •• 5. Roof Tile manufactures acquiring acceptance for the use ofHANDI STICK roof tile adhesive with t' •• •• • �i• >:rril'e. assemblies shall test in accordance with TAS 101 with'section 10.4 as modified herein. F1— MS NO.A No..::12-0228,18 Expiration Data: 0511(1 17' .Approval 054042 leagi 3 of7 INSTALLATION: 1.. 3MTM 2-Component Foam Roof Tile. Adhesive. AH-160 may be used with any ro.of tiie assembly having a current NOA that lists: uplift resistance values with the use of 3MTm 2-Component Foam RoofTile Adhesive AH-160. 2.. 3MTmi 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shalt provide sufficient attachment resistance, expressed as. an uplift based system, to. meet or exceed the uplift resistance determined in .deceourity:RmairAWEationStatidS9OFT noted in in the roof tile assembly NOA. 3. 3M1m 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2-Component Foam RoofTile Adhesive AI-1- 160. Operating instruction and Maintenance Booklet 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by 3M Company:. 3:M Company shall supply a iist of approved applicators to the authority havingjurisdiction. 5. Calibration of the Foam Dispenser RTF1000 dispensing equipment is required before: application of any adhesive. The mix ratio between the "A' component and the "Bt' component shall be maintained between 1.0-1.15 (A): 1,0 (B). The dispens:e timer shall be set to deliver 0.0175 to...G.15 pounds per tile as determined at calibration. No other settings shall be approved. 3MTm 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF I OGG or ProPack® 30. & 100 dispensing equipment only. 7. 3.MTm 2-Component Foam Roof Tile Adhesive AH-I 6G shall not be exposed permanently to sunlight..... _ .._.___ 8... Tiles must be adhered in freshly applied adhesive.. Tile must be set within 2 to 3 minutes after 3MTM Component Foam Roof Tile Adhesive: AH-I 60 has been dispensed.. 9. 3MTm 2-Component Foam Roof Tile Adhesive AH-160 placement and. minimum patty weight shall be in accordance with the 'Placement Detailsherein. Each generic tile profile requires the specific placemegi,wted herein. • • • • ••••• 4 • • • • Table 1: Adhesive: Plac.ement For Each Generic Tile Profile . • • • Tile Profile Placement Detail Single Paddy Weight Mkt. (grq1/115) • . Two Pip Weigla. per 102464 Mill, . (gratr111.1). • • Flat,. Low,, High Profiles #1 35 • • rnA :••• High Profile (2 Piece Barrel) #1 17/side on cap and 341pan •••• • • • •WA Flat, Low,. High Profiles #2. 24 • : '14A . . Flat, Low, High Profiles #3 • •2 • • • . • • • • • • • • • • • • • •• • • • • •••• NOA No. 12,0228,18 fpiration Date.: 05110/47 • Approval Date:. 05/40.42 Page 4. of 7 LABELING! All 3MTK 2-Component Foam Roof Tile Adhesive AH-I60. containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this ADHESIVE PLACEMENT DETAIL 1 SINGLE FATTY Nail thro ugh: plastic cement. Paddy (Benealh.Tile). Underlayment Nail through plastic cement • Undedayment 10.in. Faye Course Eaue course only: Keep adhesive approx. tin,up from.weepholes Fascia Eve courstonly.c Keep adhesive approx. 4.1a, up from weephotes. Paddy (Beneath. Fascia Bye:Closure; Nail:through plastic, cement Underiament 1 10.in, EaveCourse Ewa co.urse only: Keepadheske approx. weephales, Paddy. (Ben eath Tile). Fascia Weephole. Eave.closure. Drinedge • • • • • • Optional:2000r • •••• 11Place, enough:. adhrtsivato achievell to 23. steep.pitaapws Naij throughlvviement • • • • • • sguareincheslacontactwithlte..pantila 21Turo coy.= ups1da richwt.Ptace adhesive. 112 in. TO in: From outside e.dge, of overtire. Theutinstallthalite. Undedayment Remo top.pettion ortheeava course caverlile. Abate:second course: of pan bles„Ensur eaveend ot pananct coverhles are flusliat eaveline. Ewa closure. Weephole Fascia Boa (mottarshown). • • • • • • • • • • • • • it • • • Sheathing Qptional. Pnint,up•litortar on lang)turtnat edges ottile NOA Non:. 12-0228.18 • Expiration Date.: 05E1047 . Appiro.Nul air, 43S111(1132. S. QV7 • • • • • • • • • • • • • • • • LjaD 9 a2e431 ZI/01-/S0 ;aVaq g1Ao.aIdV LT/OT/S0 =nue ffi®uraagdsa 8 r8ZZO-Z➢. = oNI VON .... . • • •••• • .. • .• • • .• • • • • • • • •••• •• .. • • .. • . .. • •••• • • • • • • ..• •••• • • • .. • • . •••• • .. • • • •••• • • • • •••• e6pa dui amsopmg apgdaaM EpSej aun y— taa�t el wailmasaglitliambk ,Maya a'mII.S ABilksIvt, PLACES DETAIL 3 DOUBLE PATTY angsPeadY on top 1e Ewe e Singe Paddr between' tie EaveCkigne Vaal' &maim simpaddyearecourseordy Fascia END OF TEM ACCEPTANCE singlepaddy under Ole gngla paddy between tite . . . . .. . . 5izepaddyEaye cause Only Fascia WeePhde Eave dame Udpedge .. • . . . .... . .... .. . • • • . • .... . .. .. .. . . . .... . .... . • • . . • .• . • • • . • • • .. • .... • .... 'MA. 114228.18 Expiration Date: OStit117 Axewrov id Date~ m5/10t1l2 Paw. 1 ell • . • • • • • . . . . 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the.roof is;Rdt' •' . • over oaded from a build up of water. Perimeter/edge walls or other roof extensions may block'thit discharge if... • . over i ow scuppers (wall outlets) are not provided, It may be necessary to install overflow scuppers .i . acco • ance with the Florida Building Code, Plumbing. rA SECTION 1524 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section.. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explain 1. Aesthetics -Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be add ; ssed as part of the agreement between the owner and the contractor, 2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Buildi � Code. (The roof deck is usually concealed prior to removing the existing roof system). V 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing j?afl• • penetrations of the underside of the decking may not be acceptable. The Florida Building Gode pypvides t'tftr" • optio • f maintaining this appearance. .. . . 5. Ponding Water: The current roof system and/or deck of the building may not drain weal and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of struc�rr&l distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be ,4dirlt until.14. origina oofing system is removed. Ponding conditions should be corrected. . • . • . 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the 5 al assembly (the building itself). The existing amount of attic ventilation shall not be reduced. may be bene i ' :1 to consider additional venting which can result in extending the service life of the roof. oz Owner's/Agent's Signature Date CAlIoeumenly and Semnple4emme.U.«+I SertrngelTemplTempanry relornel FliegComent.IEStOKL8AFTNECTION 15241114ot Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: U rift r IJ, Pt ek- - Property Address: al ?o 7 N E 5" l41-' Roofing Permit Number: Dear Building Official: . I U I�uc✓ J= ie+ro certify that I am not required to retrofit the roof to w4I conn2Cti...pns•of my Date: 6/c building because: "2C0Ctc1 SA-I+Je 5 Pe 3313e . .. .. . • •••• • • • •• • • • • /The just valuation for the structure for purpose of ad valorem taxation is less than $300,000..1E please attacnproof oiad. •: • • valorem taxation. • • • • • • • .... ❑ The buildi g was construc in compliance with the provisions of the Florida Building Code•(fcor witM•tAe provisiorrs• •: • of 1994 edition of the So Ionda Building Code (1994 SFBC) • • . • Signature State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this 0 1't,v Lr .1) ' Rek-'c. Print Name • .. • • • • • • .. • • .... . • .. • • • Notary Public, Sate of Florida at Large a3 60RY•1.'`8e% MARILYN ANN CASANOVA MY COMMISSION # EE 016581 EXPIRES: September 19,2014 a Bonded Thru Budget Notary Services day of -SO me-- e: l 44'`nypifet, MARILYNANN CAS{:. * MY COMMISSION # EF: EXPIRES: September Bonded Thru Budget Notary • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. • Revised on 5/21/2009 6/23/2014 Property Search Application - Miami -Dade County Address Owner Name Folio SEARCH: 9707 ne 5 ave road, miami shores, fl PROPERTY INFORMATION Folio: 11-3206-018-0030 Sub -Division: MIAMI SHORES SEC 4 AMD RESUB Property Address 9707 NE 5 AVENUE RD Marl Shores , FL 33138-2444 Owner OLIVER R DI PIETRO Mailing Address 390 NE98 ST MIAMI SHORES , FL 33168 Primary Zone 1300 SGL FAMILY - 2801-3000 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds/Baths/Half 4/2/0 Floors 1 Livina Units 1 Suite Q ••. • • • • • •••• • • • • .. . •••• • • . . • • • • . • •••• •• • • • • . • .••• . •. ••.. .. •• •••• • • • .� • • • • • • • • •• • •••• • •••• • • http://www.miamidade.goy/propertysearch/indexhtml#/ 1/8 6/23/2014 Property Search Application - Miami -Dade County Actual Area Living Area Adjusted Area Lot Size Year Built Featured Online Tools 3,340 Sq.Ft 22,216 Sq.Ft 1951 Layers • • . http://www.miamidade.gov/propertysearch/indexhtml#/ 2/8 6/23/2014 Property Search Application - Miami -Dade County • Comparable Sales Non -Ad Valorem Assessments (http://w w w .miamidade.gov/pa/tax_estimator/non_advalorem_pop_up FoI=1132060180030) (http://vomv.miamidade.gov/pa/tax_estimator/non_adval (http://w w w .miamidade.gov/pa/tax_estimator/non_advalorem_pop_up FoI=1132060180030)PA Additional Online Tools (http://w w w .miarridade.gov/pa/online_tools.asp) Report Discrepancies (http://w w w .rniarridade.gov/pa/email/ASP/formNew .asp) Tax Comparison (http://w w w .niarridade.gov/PAPortal/Taxes/TaxCorrparison.aspx? folio=1132060180030) View Taxes (https://www .niamidade.county- taxes.com/pu blic/real_estate/parcels/1132060180030) ASSESSMENT INFORMATION Glossary (http://www.rriarrdade.gov/pa/glossary.asp) .asp? orem_pop_up.asp?FoI=1132060180030) .asperty Record Cards (http://w w w .mianidade.gov/PaPortal/PRC/CreatePRCmain.aspx) Property Search Help (http://w w w .miamidade.gov/pa/property- search-help.asp) Report Homestead Fraud (http://w w w .niarridade.gov/paportal/HomesteadFraud/HomesteadFraud.aspx) Tax Estimator (http://w w w .nianidade.gov/PAPortal/Taxes/TaxEstimator.aspx) TRIM Notice (http://w w w .niamidade.gov/paportal/trinpdf/MakeTrim.aspx? FolSrch=1132060180030) 2014 IMPORTANT NOTICE The assessment and exemption values currently show n are preliminary and are subject to change until they are certified Year Land Value Building Value Extra Feature Value Market Value Assessed Value TAXABLE VALUE INFORMATION COUNTY Exemption Value Taxable Value SCHOOL BOARD Exemption Value Taxable Value CITY 2014 $466,536 $296,565 $535 $763,636 $763,636 2013•••• • • •.$413,218..•• •• • •••• • • • • $229,2831 • • • •••• $539. • • .- •__.._• •••• • •• $643,040 •••• • • • •• •• •••• $511,710 • • • • • • • • • • • • • • • • •• • •••• • •••• • • • • • • • • • • • • • • • • • • 2014 2013 2012 $0 $763,636 $0 $763,636 cn $50,000 $50,000 $461,710 $453,157 $25,000 $25,000 $486,710 $478,157 Qcn (VIA Qcn nnn http:/Mwv.miami dade.g ov/propertysearch/i ndexhtml#/ 3/8