Loading...
FW-18-1103Miami Shores Village 10050 N.E. 2nd Avenue NW Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Permit Permit NO. FW-4-18-110 3 Permit Type: FenceMlail Work Classification: Wood Fence Pennit'Status: APPROVED Issue. Date: 4/27/2018 Expiration: 10/24/2018 Parcel Number Applicant 138 NW 107 Street Miami Shores, FL 33168- 1121360080200 Block: Lot: MARVIN ARMSTRONG Owner Information Address Phone CeII MARVIN ARMSTRONG 138 NW 107 Street MIAMI SHORES FL 33168- Contractor(s) HOME OWNER Phone CeII Phone Valuation: Total Sq Feet: $ 3,000.00 145 Approved: Comments: Date Approved: : Date Denied: Type of Construction: Wood Fence Classification: Residential Additional Info: DURA FENCE WHITE COLOR 6 FT F Scanning: 3 Fees Due CCF DBPR Fee DCA Fee Education Surcharge Notary Fee P&Z Review Fee Permit Fee - Wire & Wood Scanning Fee Technology Fee Total: Amount $1.80 $2.18 $2.00 $0.60 $5.00 $35.00 $145.00 $9.00 $2.40 $202.98 Pay Date Pay Type Invoice # FW-4-18-67307 04/26/2018 Check #: 259 04/27/2018 Check #: 249 Amt Paid Amt Due $ 50.00 $ 152.98 $ 152.98 $ 0.00 Available Inspections: Inspection Type: Final Foundation Review Building Review Public Works Review Planning In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify zo- ing. Futh6r construction uthoriz all the f e, I au g Information is accurate and that all work will be done in compliance with all applicable laws regulating orize the above -named contractor to the work stated. / 'Applicant / Contractor / Agent April 27, 2018 Date Building Depart 'ant Copy April 27, 2018 1 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS JOB ADDRESS: City: RECEIVED APR 2 6 MR FBC rr200 Master Permit No. 'RN 1,6 — t 103 Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS 132 AJ u/ lD7 Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes Occupancy Type: Load: Construction Type: Flood Zone: BFE: NO FFE: OWNER: Name (Fee Simple Titleholder): M a of /i% 8 - - , Arms- 7Dy% hone#9.-57- 3)'' 7.-2r C-7 Ada :/CP 071/W /0 7 S- City (Q yj'Yi .S%QrP J State: r2---- Zip: 33/ Tenant/Lessee Name: Email:414'09/1T /3® /77(-ceiv-Y) CONTRACTOR: Company Name: Address: City: State: Zip: Qualifier Name: Phone#: State Certification or Registration #: Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Square/Linear Footage of Work: X /46 T ❑ New ❑ Repair/Replace LI Demolition �h, t �l'- , 474 h I \or'c Dwnrr Phone#: Phone#: erA: e2 & ❑ Alteration Peeri ce—� /✓16404I., /5-,/ s/, d/5 C�r Value of Work for this Permit: Type of Work: ❑ Addition Description of Work:, 62 -6 Specify color of color thru tile: Submittal Fee $ Permit Fee $ CCF $ Scanning Fee $ Radon Fee $ DBPR $ Technology Fee $. " Training/Education Fee $ Structural Reviews $ (Revised02/24/2014) CO/CC $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address 'City r State Zip } Mortgage Lender's Name'(if applicable) Mortgage Lender Address 4 City j .t `"' , $ `+., State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that a. II the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." \ Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the'job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved a • reinspection fee will be charged. _ Signature Al Ail Signature CONTRACTOR The foregoing instrument : s ackno ledged before me this The foregoing instrument was acknowledged before me this . day of or AGE 20 19 , by day of , 20 , by Marvin E • :-tyys-{'01who is personally known to , who is personally known to me or who has produced 1) rilr' iY l 1 C`Cl1S f as me or who has produced as identification _ • • who NOTARY P BLIC: I \ NOTARY PUBLIC: Sign: Print: Seal: 4 �...,. �_ yANaD ��IEro *__ 'QOMMISSI�`r #FF214031 e El(PIRES: March 25, 2019 Bo,* TA tbtary Pubx Underwriters *****************************Jt***** APPROVED BY (Revised02/24/2014) identification and who did take an oath. } Sign: - r Print: a Seal: ***********************************************s*****�t_************* Plans Examiner Structural Review 4f i f r!r Po&jc. L'-'6A-KC Zoning Clerk 4/26/2018 Property Search Application - Miami -Dade County OFFIC Summary Report Property Information Folio: 11-2136-008-0200 Property Address: 138 NW 107 ST Miami Shores, FL 33168-4309 Owner MARVIN E ARMSTRONG Mailing Address 138 NW 107 ST MIAMI SHORES, FL 33168-4309 PA Primary Zone 0800 SGL FAMILY - 1701-1900 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds / Baths / Half 2/2 / 0 Floors 1 Living Units 1 Actual Area 1,570 Sq.Ft Living Area 1,242 Sq.Ft Adjusted Area 1,406 Sq.Ft Lot Size 9,150 Sq.Ft Year Built 1950 Assessment Information Year 2017 2016 2015 Land Value $196,886 $164,440 $164,440 Building Value $97,858 $97,858 $97,858 XF Value $4,223 $4,269 $3,596 Market Value $298,967 $266,567 $265,894 Assessed Value $102,270 $100,167 $99,471 Benefits Information Benefit Type 2017 2016 2015 Save Our Homes Cap Assessment Reduction $196,697 $166,400 $166,423 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values ('.e. County, School Board, City, Regional). Short Legal Description DUNNINGS MIAMI SHORES EXT 4 PB 48-20 LOT 4 BLK 205 LOT SIZE 75.000 X 122 OR 14843-2606 1290 1 Generated On : 4/26/2018 Taxable Value Information 2017 2016 2015 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $52,270 $50,167 $49,471 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value $77,270 $75,167 $74,471 City Exemption Value $50,000 $50,000 $50,000 Taxable Value $52,270 $50,167 $49,471 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value $52,270 $50,167 $49,471 Sales Information Previous Sale Price OR Book -Page Qualification Description 12/01/1990 $71,000 14843-2606 !Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: NAME: Atavv(/J 4t7)11; ADDRESS: /3 '/VW /07 Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, F.S 489.103(7). And I have read and understood the following disclosure statement, which entitles me to work as my own contractor; I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor, You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one -family or two-family residence. You may also build or improve a commercial building at a cost of $25,000.00 or less (The new form states 75,000). The building must.be for your own use and occupancy. It may not be built for sale or lease. If you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and with -holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, buildings codes and zoning regulations. Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNER BUILDER DISCLOSURE STATEMENT 423-0 DATE: Please read and initial each paragraph. 1. I understand that state law requires construction to be done by a licensed contractor and have applied for an owner -builder permit under an exemption from the law. The exemption specifies that I, as the owner of the property listed, may act as my own contractor with certain restrictions even though I do not have a license. Initial 2. I understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. Initial 3. I understand that, as an owner builder, I am the responsible party of record on a permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that the contractor is required by law to be licensed in Florida and to list his or license numbers on permits and contracts. Initial 4. ,t I understand that I may build or improve a one family or two-family residence or a farm outbuilding. I may also build or improve a commercial buildingif the costs do not exceed $75,000. The building or residence must be for my use or occupancy. It may not be built or substantially • improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within 1 year after the construction is complete, the law will presume that I built or substantially improved it for sale or lease, which violates the exemption. Initial 5. I understand that, as the owner -builder, I must provide direct, onsite supervision of the construction. Initial 6. f I understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure that the persons whom I employ have the license required by law and by county or municipal ordinance. Initial 7. I understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner -builder permit that erroneously implies that the property owner is providing his or her own labor and materials. I, as an owner -builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner -builder and am aware of the limits of my insurance coverage for injuries to workers on my property. Initial 8. I understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the work being done. Any person working on my building who is not licensed must work under my direct supervision and must be employed by me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the . Federal Insurance Contributions Act (FICA) and must provide workers`compensation for the employee. I understand that my failure to follow these may subject to serious financial risk. Initial 9. I agree that, as the party legally and financially responsible for this proposed Construction activity, I will abide by all applicable laws and A requirement that govern owner -builders as well as employers. I also understand that the Construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. 1 Initial 10. I understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service, the United States Small Business Administration, and the Florida Department of Revenues. I also understand that I may contact the Florida Construction Industry Licensing Board at 850.487.1395 or http://www.mvfloridalicense.com/dbpr/pro/cilb/index.htrnl Initial 11. I am aware of, and consent to; an owner -builder building permit applied for In my name and understands that I am the party legally and financially responsible for t roposed ruction activity at the following address: Initial 12. I agree to notify Miami Shores Village immediately of any additions, deletions, or changes to any of the infor ation that I have provided on this disclosure. Initial Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of contractor may be in civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an individual or firm is injured while working on your property, you may be held liable for damages. If you obtain an owner -builder permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is properly licensed and the status of the contractor's workers compensation coverage. Before a building permit can be issued, this disclosure statement must be completed and signed by the property owner and returned to the local permitting agency responsible for issuing the permit. A copy of the property owner's driver license, the notarized signature of the property owner, or other type of verification acceptable to the local permitting agency is required when the permit is issued. Was acknowledgedbefore me this BY Marv►n � �Yrr�S�rora Produced there OW ER day of Ppr 1 6 20 1 was personally known tome or who has as identification. NOTARY • Affiant is personally known to me, Revised on 5/22/2009/ Revise Miami Shores Village Building Department SURVEY AFFIDAVIT STATE OF (FLORIDA) COUNTY OF (DADE) The undersigned Affiant, 7 jl k , S;1Re by attest that (Property owner)„ The attached survey, performed by 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 (Name of su eyor's company) For address: A iv /0 7 Performed on (date of survey) is an accurate representation of the existing conditions and locations of all structure on the property as of this date. The purpose of this Affidavit is to induce Miami Shores Village to issue a building permit for the property without first providing a survey Tess than seven (7) years old old. The Affiant, as property owner, further agrees to remove or obtain permits for any structures which now may exist on the property which are not permitted or which may Iviolate zoning or building code regulations. The Affiant further understands that the existence of any such structures may affe nal inspe '•ns as applicable to this or other permits. F r - r Affiant say Ia• 1 i iggam / [&'(/1 //rKh4IJ1( Props Ow r Sign. - Property Owner Print Name SWORN TO AND S ' : ED before me this (/, day of �' produced 41 11 1 5_4' s identification. ya r ti U r rri CO Or n O N 44, Co r Ors_ C)O OU ca (11 a� N r- 122. 23'(P) ) 261 r o Bearing, if any, shown based on N/A 4.55 122.25'(M) 122.28'(P) (reference) N/A 0.20' 15.00 -0.20' t' Miami Shows VIII Igo APPROVED gym ZONING DEPT BLDG DEPT SULJL-l; I l c) COMPLU,�TI-1 ALL i-- r STATE ANINcO JN1i1S' RtU ES A NDE EGuh,TlON,S 37.50' .lVMHdVd ,se 37.50' (Z 133111s 4DL0I This property described as: Lot 4, Block 205, DUNNING'S MIAMI SHORES EXTENSION N24, according to the Plat thereof as recorded in Plat Book 48, Page 20, of the Public Records of Miami -Dade County, Florida. CERTIFIED TO: Marvin E. Armstrong 138 N.W. 107th Street, Miami Shores, FL 33168 RECEIW EU. APR 2 6 MB 4441111 "THIS SURVEY DECLARATION IS MADE ON THE FIELD DATE INDICATED, TO THE OWNER(S) LISTED. IT IS NOT TRANSFERABLE TO ADDITIONAL INSTITUTIONS OR SUBSEQUENT OWNERS." 0 g• � C ' €61 C N h U .O-. c L O N O-. NC22 '08O N . C c2avw;ay w O s .E °: o m.2v' 2 C N J 2 Eddy&"vvy �vv>>vc B `0O d e a aciv °cy Q �E6.) oE• y o a al N `+ V (- l9 1V- c1dm - 10 may 2 o,2H928g mod = a ,T 8 0 ✓ y E ° y v m G 2 0 o c m$ y r � m c ao .240, `0 �o m oeNyaCa)a m m 0 C O 8L C-c°.0 ° N C c r y y o o° c a a 3 r V O L V o U O a H m' v 11-,3`4 p I) 5 av E 2:221 ay'y Em•(5=O2. c10i`o yJ UQZOI-- N U c vt=., • e -910 .2 • c ° =w ti o ; Tao of� d a ° 2 mo•r a ° ��9 as N C) 7 O g 0 • w ›....4,_ ° 2 0.3 y a yam ,p y ,„ I:,,L_ -. u°�l • m .0 v a m r cmEY NOC°;▪ .• >: .0.OlCCO NCyyi;dNCyw'°Ov+N'O pN CvrUC - (pN C c02E° o 2= E yE ov,o;o u°iy�C_Ho O i'_ 2 v 21 C Ol " C m — T C C C 10 O N_ N v N a« �7, c j °O N N u ° v IO rr U O C U C C E C N C 7' O `2 ;Noy ° o o • H L�'o 0 • al , y y yc Olt c O C .0 .0 z • a civ et LEGEND A = Central Angle A =Arc A/C = Air Conditioner ASPH = Asphalt BBQ = Barbecue BM = Bench Mark CB = Catch basin CBS = Concrete Block Structure CH = Chord Chatty = Chattahoochee = Center Line CLF = Chain Link Fence Cl. = Clear Conc. = Concrete D = Deed 0 = Diameter DC = Miami -Dade County DH = Drill Hole DME = Drainage & Maintenance Easement Enc. = Encroachment F.H. = Fire Hydrant F.I.R. = Found Iron Rebar FPL = Florida Power & Light F.I.P. = Found Iron Pipe Fd. = Found M = Measured 1�1 = Monument Line Mon. = Monument N/A = Not Applicable N/D = Nail & Disc N- = Number NTS = Not to Scale O/S = Offset O.U.L. = Overhead Utility Lines OH = Overhang P = Plat PB = Plat Book PC = Point of Curvature PCP = Permanent Control Point PG = Page P.I. = Point of Intersection PKWY= Parkway = Property Line P L = Planter P.O.B.= Point of Beginning P.O.C.= Point of Commencement P.P. = Power Pole P.R.M.= Permanent Reference Monument PT = Point of Tangency R = Radius Res. = Residence RNG = Range R/R = Railroad PSM = Professional Surveyor Mapper R/W = Right -of -Way SWK = Sidewalk Sec. = Section TR = Tract (TYp) = Typical T = Tangent TWP = Township U.E. = Utility Easement W.F. = Wood Fence W.M. = Water Meter REVISIONS: FLOOD ZONE X COMM. No. 120652 PANEL No. 0090 SUFFIX. • F.I.R.M.DATE 03/02/94 F.I.R.M.INDEX 07/17/95 BASE ELEV. + N/A N.G.V.D. ELEVATION NOTE: (IF APPLICABLE) L.F.Elev.= N/A (lowest habitable floor elevation). Elevation shown hereon refer to N.G.V.D. 1929. Lowest adjacent grade elevation= N/A BM. N/A Elev.= N/A Garage Elev.= N/A Frp.= N/A . Not valid unless it bears the signature and the original raised seal of Florida licensed Surveyor and Mapper. BOUNDARY SURVEY. I HEREBY CERTIFY: that this survey meets the minimum technical standards as set forth by the FLORIDA BOA' ra • •% SSI S "' L SURVEYORS AND MAPPER in chi r 61 G17-. lorida Administrative Code, pursuan o Section r .027 Florida Statutes. SVIVES 12/17/07 P"iFESSISN' SURVEYOR AND APPER No. 4327. State of Florida. Alvarez, Aiguesvives and Associates, Inc. Surveyors, Mappers and Land Planners 5701 S.W. 107th Avenue #206, Miami, FL 33173 Phone 305.220.2424 Fax 305.552.8181 L.B. No. 6867 / E-mail: aaasurvey@aol.com Field Date 12/14/07 Scale: 1 "= 20' Drawn by: D.G. Drwg. No. a 07-12375 a,a 4'-0" MAX a QUALITY METAL PANELS GENERAL NOTES 1. ALL WORK SHALL CONFORM TO FLORIDA BUILDING CODE 2017. 2. IT IS THE INTENT OF THESE DRAWINGS TO BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION. ANY DISCREPANCIES BEIWEEN THESE DRAWINGS AND APPLICABLE CODES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO MEET WITH ALL APPLICABLE UT1UTY COMPANIES TO VERIFY ALL UNDER- GROUND FACILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION. ALL EXCAVATIONS SHALL PROCEED WITH EXTREME CAUTION AT ALL TIMES. IN THE EVENT THAT EXISTING UTILITIES ARE DAMAGED, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR OR REPLACE ALL DAMAGES. 4. THIS WORK REQUIRES A BUILDING PERMIT. DO NOT BEGIN WORKING UNTIL A BUILDING PERMIT IS OBTAINED. 5. CONTRACTOR IS TO FURNISH ALL LABOR. MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 6. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 7. ENGINEER'S VISITS TO THE SITE, AS PER G.0 OR OWNER'S REQUEST DURING CONSTRUCTION SHALL BE SCHEDULED WITHIN 24 HOURS PRIOR TO INSPECTION. 8. THE CONTRACTOR SHALL MAKE REQUIRED ARRANGEMENTS, SECURE AND PAY FOR ALL BARRICADES, ENCLOSURES, AND FENCING AS NEEDED FOR AND DURING THE PROGRESS TO PROTECT ADJACENT PROPERTIES. 9. THE CONTRACTOR SHALL NOT PROCEED WITH ANY ADDRIONAL SERVICES OR WORK WITHOUT PRIOR NOTIFICATION TO THE OWNER. 10. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS CONSTRUCTION, AND FOR THE SEQUENCES AND PROCEDURES TO BE USED. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMIUARIZING WITH CURRENT SITE CONDITIONS, AND SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO STARTING WORK. 12. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE JOB SITE. ANY DISCREPANCIES BETWEEN PLANS, SECTIONS AND DETAILS OR THE APPLICABLE CODES OR REGULATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER DURING BIDDING OR BEFORE WORK BEGINS IN ORDER TO CLARIFY THE REQUIREMENTS AND TO EFFECT THE NECESSARY MODIFICATIONS, CHANGES AND /OR INSTRUCTIONS. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR RESETTING ALL DISTURBED EXISTING CONDITIONS AND PROPER DISPOSAL OF ANY EXTRA MATERIALS & GARBAGE FROM THE SITE AFTER COMPLETION OF WORK. 14 DRAWINGS AND DIMENSIONS ARE BASED UPON DRAWINGS SUPPLIED BY THE CUENT. EASTERN ENGINEERING GROUP WILL NOT BE RESPONSIBLE FOR ERRORS OR MISINTERPRETATIONS OF THE SYSTEM DESIGNED BY US BASED ON CUENT CONFIRMED DESIGN AND DIMENSIONS. ADDlT10NAL DRAFTING TIME EMPLOYED IN THE CHANGE OF THE DESIGN AFTER SIGNING AND SEALING OF DRAWINGS WILL RESULT IN ADDMONAL COST. 15. DO NOT SUBSTITUTE MATERIALS, EQUIPMENTS OR METHODS OF CONSTRUCTION UNLESS SUCH SUBS11T1JTIONS OR CHANGES HAVE BEEN APPROVED IN WRITING BY THE OWNER. DESIGN LOADS FENCE WIND LOAD AS PER ASCE 7-10 KD=0.85 WIND VELOCITY AS PER ASCE 7-10 MIAMI-DADE CATEGORY 2 115 mph AS PER FBC 2017 SECTION 1616.2.1 CALCULATIONS ........................................................................................................................................ In accordance with FBC 2017 and ASCE 7-10 1. STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE AND AISC SPECIFICATIONS NINTH EDITION. 2. STRUCTURAL STEEL SHALL MEET THE FOLLOWING REQUIREMENTS: TYPE ASTM GRADE STEEL SHEETS A36 STRUCTURAL TUBING A500 B 3. ALL Sit EL SHALL BE HOT -DEEP GALVANIZED. Fy 36 KSI 46 KSI 4. PAINT STEEL HOT GALVANIZED SURFACES IN CONTACT WITH CONCRETE WITH ALKALI -RESISTANCE COATINGS, SUCH AS HEAVY -BODIED BITUMINOUS PAINT OR WATHER-WHITE MOTHACRYLATE LACQUER ;Wind load Calculation: General Data: Post Design Category ..__.... Exposure: V (mph): Kd: h (ft): L (ft) ..... 4 Hpost (ft) 6 115.00 .......... 1.00 . 0.85 6 16.2 Fy (psi) 46000 A-500 Fb (psi).27600 Fv (psi) 18400 Fy (psi) 36000 A-36 Fb (psi) 21600 Fv (psi) 14400 Rail to Posts Connection Design Actual Pullout 194.4 Allowable Pullout 200 Using 10-16 OK Flex Screw Hilti Kwik Top and Bottom Design 21/2x2 1/2x16 gage steel galvanized 2x1x0.071 St -galvanized Mmax. (lb -in) 13997 : Mmax. (lb -in) 1166 Zx (inA3).... M1 0.75 Sx (in 3) ...__ 0 086 ... "fb (psi) Mmax/Sx fb (Psi)M Mmax/Sx, fb (psi) 18662 fb (psi) 13562.8 fb (psi)<Fb OK ...... fb (psi)<Fb ..... OK. Foundation Design (nonconstrained FBC 2017 -1807.3.2.1) P 388.80 Lateral soil bearing 200 A 144 Footing Diameter (f4 1.583 d 3.00 For poles 1806.3.4 2 0.06 • S=0.47 IN' Z=0.58 IN' Mmax=16.2*4*6*6/2 =13 997 f-in M Aso=Mn/D . Mn=F?Z , 0 =1.67 MI Aso=16 000 #-in Mmax < M ASO 1 2 r a it 40 _1. .. . . . . TYP. FENCE PLANVIEW SCALE: 3/4"=1'-0" 4'-0" MAX u II II II II II II II FENCE CONNECTIONS: - RAIL TO POSTS TO BE CONNECTED 'WITH (2) 10-16 KWIK FLEX SCREW by HILTI OR APPROVED EQUAL ACCESS HOLE AT RAILS TO BE PROVIDED FOR CONNECTION, OR BE d" WELD 1" WELD LENGTH IN 2 OPOSITE SIDES MINIMUM. - PICKETS TO BE CONNECTED TO TOP AND BOTTOM RAILS WITH (4 PER PICKET, 2 TOP & 2 BOTTOM) 10-16 KWIK FLEX SCREW by HILT] OR APPROVED EQUAL, OR BY 1/4" PUDDLE WELDS. S=0.124 INN. Mmax=16.2*6*.5*4*4/8 =1 166 #-in M Aso=Mn/0 , Mn=Fy*S fl =1.67 M Aso=2 673 #-in Mmax < M ASO 0.06 i 2" TYP. FENCE ELEV. VIEW SCALE: 3/4"=1'-0" ir S = 0.0863 IN' Mmax=16.2*6*.5" 4*4/8 =1 166 #-in M Aso=Mn/f) Mn=Fy*S , 0 =1.67 M Aso=16 167 #-in Mmax < M ASD 0.04 • 2" N 0.06 S=0.48 IN' Z=0.60 IN' Mmax=16.2*4*6*6/2 =13 997 #-in M Aso=Mn/0 Mn=FyZ , 0 =1.67 M Aso=16 530 #-in • Mmax <MA50 2 1/2" u 2x1x16 GA GALVANIZED STEEL TUBE RAIL TOP MEMBER 24 GA (MIN.) GALVANIZED METAL SHEET 2.5x2.5x16 GA. GALVANIZED STEEL POST SPACED 4'-0" MAX. O.C. 2x1x16 GA GALVANIZED STEEL TUBE RAIL BOT. MEMBER 3000 PSI CONCRETE FOOTING 012"x4'-0" DEEP OR 019"x3'-0" DEEP OR 024"x2'-6" DEEP APPLI BABL EXCLUSIVE ONLY FOR SEDIMENTARY ,AND FOLIATED ROCK SOILS 012"x2'-9" DEEP Z=0.0074 IN' Mmax=16.2" (6.125/ 12)•3.33.3.33*0.125.12 =135 #-in M Aso-.Mn/0 Mn=Fy*Z 0 =1.67 M Aso=160 #-in Mmax < M ASO 6 r 0 O 1 2 a Tel. 786 9169 297 11 ORAISSA R. LOPQ,PE ❑OONZN.O A. PALPE 1/9(2018 SD-1 POSTS (16 GA) RAILS (16 GA) ALTERNATIVE RAILS (19 GA) ALTERNATIV E POSTS (16 GA) PICKETS (27 GA) 911 NM POST FENCE TO BE AT NO MORE THAN 4' NEXT POST FENCE TO BE AT NO MORE THAN 4' 8 s 31 xS a g 9 f i� sd 23 88 18 a2 a a a s a s QUALITY METAL PANELS GENERAL N117189 1. ALL WORK SHALL CONFORM TO FLORIDA BUILDING CODE 2017. 2. IT IS THE INTENT OF THESE DRAWINGS TO BE IN ACCORDANCE WITH APPUCABLE CODES AND AUTHORITIES HAVING JURISDICTION. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND APPUCABLE CODES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER. 3.17 SHALL BE : THE CONTRACTORS RESPONSIBILITY TO MEET - WITH ALL APPUCABLE UTILITY COMPANIES TO VERIFY ALL UNDER- GROUND FACILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION. ALL EXCAVATIONS SHALL PROCEED WITH EXTREME CAUTION AT ALL TIMES. IN THE EVENT THAT EXISTING UTILITIES ARE DAMAGED, IT SHALL BE THE RESPONSIBIUfY OF THE CONTRACTOR TO REPAIR OR REPLACE ALL DAMAGES. 4. THIS WORK REQUIRES A BUILDING PERMIT. D0 NOT BEGIN WORKING UNTIL A BUILDING PERMIT IS OBTAINED. 5. CONTRACTOR IS TO FURNISH ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK SHOWN ON THE. DRAWINGS AND SPECIFIED HEREIN. 6. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 7. ENGINEER'S VISITS TO THE SITE, AS PER G.0 OR OWNER'S REQUEST DURING CONSTRUCTION SHALL BE SCHEDULED WITHIN 24 HOURS PRIOR TO INSPECTION. 8. THE CONTRACTOR SHALL MAKE REQUIRED ARRANGEMENTS, SECURE AND PAY FOR ALL BARRICADES, ENCLOSURES, AND FENCING AS NEEDED FOR AND DURING THE PROGRESS TO PROTECT ADJACENT PROPERTIES. 9. THE CONTRACTOR SHALL NOT PROCEED WITH ANY ADDITIONAL SERVICES OR WORK WITHOUT PRIOR NOTIFICATION TO THE OWNER. 10. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS CONSTRUCTION. AND FOR THE SEQUENCES AND PROCEDURES TO BE USED. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMIUARIZING WITH CURRENT SITE CONDITIONS, AND SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO STARTING WORK. 12. CONTRACTOR SHALL VERIFY AU. DIMENSIONS AND EXISTING CONDITIONS AT THE JOB SITE. ANY DISCREPANCIES BETWEEN PLANS, SECTIONS AND DETAILS OR THE APPUCABLE CODES OR REGULATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER DURING BIDDING OR BEFORE WORK BEGINS IN ORDER TO CLARIFY THE REQUIREMENTS AND TO EFFECT THE NECESSARY MODIFICATIONS, CHANGES AND /OR INSTRUCTIONS. , 13. CONTRACTOR SHALL BE RESPONSIBLE FOR RESETTING ALL DISTURBED EXISTING CONDITIONS AND PROPER DISPOSAL OF ANY EXTRA MATERIALS & GARBAGE FROM THE SITE AFTER COMPLETION OF WORK. 14 DRAWINGS AND DIMENSIONS ARE BASED UPON DRAWINGS SUPPUED BY THE CUENT. EASTERN ENGINEERING GROUP WILL NOT BE RESPONSIBLE FOR ERRORS OR MISINTERPRETATIONS OF THE SYSTEM DESIGNED BY US BASED ON CUENT CONFIRMED DESIGN AND DIMENSIONS. ADDITIONAL DRAFTING TIME EMPLOYED IN THE CHANGE OF THE DESIGN AFTER SIGNING AND SEALING OF DRAWINGS WILL RESULT IN ADDITIONAL COST. 15. DO NOT SUBSTITUTE MATERIALS, EQUIPMENTS OR METHODS OF CONSTRUCTION UNLESS SUCH SUBSTITUTIONS OR CHANGES HAVE BEEN APPROVED IN WRITING 8Y THE OWNER. DESIGN LOADS FENCE WIND LOAD AS PER ASCE 7-10 KD=0.85 WIND VELOCITY AS PER ASCE 7-10 MIAMI-DADE CATEGORY 2 115 mph AS PER FBC 2017 SECTION 1616.2.1 CALCULATIONS In accordance with FBC 2017 and ASCE 7-10, _ Wind Speed from FBC 2017, Chapter 16, Section 1616.2.1 v=115 mph Wind load Calculation: General Data DL(psf): 5 V (mph). 115.00 Fence Span(ft): 4 Gate Span(ft): 4 Exposure: C Hpost (ft) 6 Post Design 1. STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE AND AISC SPECIFICATIONS NINTH EDITION. 2. STRUCTURAL STEEL SHALL MEET THE FOLLOWING REQUIREMENTS: TYPE ASTM GRADE Fy STEEL SHEETS A36 36 KSI STRUCTURAL TUBING A500 B 46 KSI 3. ALL STEEL SHALL BE HOT -DEEP GALVANIZED. 4. PAINT STEEL HOT GALVANIZED SURFACES IN CONTACT WITH CONCRETE WITH ALKAU-RESISTANCE COATINGS, SUCH AS HEAVY -BODIED BITUMINOUS PAINT OR WATHER-WHITE MOTHACRYLATE LACQUER Gust Factor 0.85 Cf: 1 30 _. Kd: 0.85 6 00 . 0.85 qz (psf): 16.2 Rail to Posts Connection Design Actual Pullout 32 Allowable Pullou 200 Using 10-16 Hilt Fy (psi) 46000 A-500 Fb (psi) 27545 Fv (psi) -18400 Fy (psi) 36000 A-36 Fb (psi) 21600 Fv (psi) 14400 :Top and Bottom Design (Gate Span = Gate Leaf, not opening) 2x1x0.071 st galvanized Steel galvanized A-500 'Section Mwind . MDL 2.5x2.5x16Ga 14012 2880 ,A-500 Mmax. (lb -in) 2608 (lb -in) Z. (InA3): fb (psi) Sx (inA3) 0.124 14305 0.5824663.7E fb (psi) Mmax/Sx fb (psi) 21029.E fb (psi)<Fb OK fb (psi)<Fb OK OK. Flex Screw Foundation Design (nonconstrained FBC 2017 -1807.3.2.11 (2017 -1806.2) 583.83 Lateral soil bearing 200 Kwik: A 2.1E Footing Diameter (ft) 1.58333 d (Depth) 3.95 • For poles 1806.3 2 3'-074'-0" MAX 2x1x16 GA. GALVANIZED STEEL FRAME GATE (rep) GALVANIZED SILF.L POST 2-1/2"x2-1/2"x16GA 24 GA. (MIN.) GALVANIZED METAL SHEET ()URA FENCE m M) 2x1x16 GA. GALVANIZED STEEL FRAME GATE MP) HINGES TO RESIST 180 LBS 2x1x16 GA. GALVANIZED STEEL FRAME GATE (NI MP) GATE CONNECTIONS: - PICKETS TO BE CONNECTED TO TOP AND BOTTOM RAILS WITH (4 PER PICKET, 2 TOP & 2 BOTTOM) 10-16 KWIK FLEX SCREW by HILTI OR APPROVED EQUAL GALVANIZED STEEL POST 2-1/2"x2-1/2"x16GA Hr t n-IT- 4 II I II 11 III I II IJ M LOCI Il 1 HARD*RE I N 1 II 0 uJ m 0.06 S=0.47 IN' Z=0.58 IN' Mmax=14 305 #-in M Aso=Mn/0 , Mn =Fy*Z 0 =1.67 M Aso=16 000 #-in Mmax < M ASO 2 f SINGLE GATE ELEV. WA! SCALE: 3/4"=1'-0" 3'-0" /4'-0" MAX TYP. SINE CRATE HA t S=0.124 IN' Mmax=2 608 #-in M Asp=Mn/(1 , Mn=Fy*S 0 =1.67 M Asp=2 673 #-in Mmax < M ASD 0.06 2" 4. SCALE: 3/4"=1'-0" 0.06 G S=0.48 IN' Z=0.60 IN' Mmax=14 305 #-in M Asp=Mn/0 Mn=Fy*Z , 11 =1.67 M Aso=16 530 #-in Mmax < M Aso 2 1 /2" 0 l,) N x • 0 0 i0 z 3 KSI CONC. FOOTING 012"x4'-0" DEEP OR 019"x3'-0" DEEP OR 024"x2'-6" DEEP (TYP) APPLICABLE EXCLUSIVE ONLY FOR SEDIMENTARY AND FOLIATED ROCK SOILS 012"x2'-9" DEEP - ALL GATE FRAMES TO BE CONNECTED BY ALL AROUND FILLET WELD. Z=0.0074 IN' Mmax=16.2*(6.125/12)*2.42*2.42*0.125112 =72 #-in M Aso=Mn/0 , Mn=Fy*Z 0 =1.67 M Asp=160 #-in Mmax <MAso 1 6 ;" 0 1 911 Oai 786 9169 297 �s5 ❑RAISSA R. LOPEZ,PE ❑G0117.ALO A. PAZ.PE 1, 72018 SD-2 1 8 i QUALITY METAL PANELS GENERAL NOTES 1. ALL WORK SHALL CONFORM TO FLORIDA BUILDING CODE 2017. 2. IT IS THE INTENT OF THESE DRAWINGS TO BE IN ACCORDANCE WITH APPUCABLE CODES AND AUTHORITIES HAVING JURISDICTION. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND APPUCABLE CODES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER. 3.1T SHALL BE THE CONTRACTORS RESPONSIBILITY TO MEET WITH ALL APPUCABLE UTILITY COMPANIES TO VERIFY ALL UNDER- GROUND FACILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION. ALL EXCAVATIONS SHALL PROCEED WITH EXTREME CAUTION AT ALL TIMES. IN THE EVENT THAT EXISTING UTILITIES ARE DAMAGED. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR OR REPLACE ALL DAMAGES. 4. THIS WORK REQUIRES A BUILDING PERMIT. DO NOT BEGIN WORKING UNTIL A BUILDING PERMIT IS OBTAINED. 5. CONTRACTOR IS TO FURNISH ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 6. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 7. ENGINEER'S VISITS TO THE SITE. AS PER G.0 OR OWNER'S REQUEST DURING CONSTRUCTION SHALL BE SCHEDULED WITHIN 24 HOURS PRIOR TO INSPECTION. 8. THE CONTRACTOR SHALL MAKE REQUIRED ARRANGEMENTS, SECURE AND PAY FOR ALL BARRICADES. ENCLOSURES, AND FENCING AS NEEDED FOR AND DURING THE PROGRESS TO PROTECT ADJACENT PROPERTIES. 9. THE CONTRACTOR SHALL NOT PROCEED WITH ANY ADDITIONAL SERVICES OR WORK WITHOUT PRIOR NOTIFICATION TO THE OWNER. 10. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS CONSTRUCTION. AND FOR THE SEQUENCES AND PROCEDURES TO BE USED. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING WITH CURRENT SITE CONDITIONS, AND SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO STARTING WORK. 12. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE JOB SITE. ANY DISCREPANCIES BETWEEN PLANS, SECTIONS AND DETAILS OR THE APPLICABLE CODES OR REGULATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER DURING BIDDING OR BEFORE WORK BEGINS IN ORDER TO CLARIFY THE REQUIREMENTS AND TO EFFECT THE NECESSARY MODIFICATIONS, CHANGES AND /OR INSTRUCTIONS. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR RESETTING ALL DISTURBED EXISTING CONDITIONS AND PROPER DISPOSAL OF ANY EXTRA MATERIALS & GARBAGE FROM THE SITE AFTER COMPLETION OF WORK. 14 DRAWINGS AND DIMENSIONS ARE BASED UPON DRAWINGS SUPPUED BY THE CLIENT. EASTERN ENGINEERING GROUP WILL NOT BE RESPONSIBLE FOR ERRORS OR MISINTERPRETATIONS OF THE SYSTEM DESIGNED BY US BASED ON CLIENT CONFIRMED DESIGN AND DIMENSIONS. ADDITIONAL DRAFTING TIME EMPLOYED IN THE CHANGE OF THE DESIGN AFTER SIGNING AND SEALING OF DRAWINGS WILL RESULT IN ADDITIONAL COST. 15. DO NOT SUBSTITUTE MATERIALS. EQUIPMENTS OR METHODS OF CONSTRUCTION UNLESS SUCH SUBSTITUTIONS OR CHANGES HAVE BEEN APPROVED IN WRITING BY THE OWNER. DESIGN LOADS FENCE WIND LOAD AS PER ASCE 7-10 KD=0.85 WIND VELOCITY AS PER ASCE 7-10 MIAMI-DADE CATEGORY 2 115 mph AS PER FBC 2017 SECTION 1616.2.1 CALCULATIONS 1. STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE AND AISC SPECIFICATIONS NINTH EDITION. 2. STRUCTURAL SittL SHALL MEET THE FOLLOWING REQUIREMENTS: TYPE STEEL SHEETS STRUCTURAL TUBING ASTM A36 A500 3. ALL STEEL SHALL BE HOT -DEEP GALVANIZED. GRADE Fy 36 KSI B 46 KSI 4. PAINT STEEL HOT GALVANIZED SURFACES IN CONTACT WITH CONCRETE WITH ALKALI -RESISTANCE COATINGS, SUCH AS HEAVY -BODIED BITUMINOUS PAINT OR WATHER-WHITE MOTHACRYLATE LACQUER In accordance with FBC 2017 and ASCE 7-10, Wind Speed from FBC 2017, Chapter 16, Section 1616.2.1 v=115 mph Wind Toad Calculation: General Data: V (mph): Exposure: Gust Factor Cf: Kd: h (ft): Kz: 4z (Ps): 115.00 Fence Span(ft): 4 C Hpost (ft) 6 0.85 1.30 0.85 6.00 Fy (psi) 36000 Fy (psi) 46000 A-500 Fb (psi) 27545 Fv (psi) 18400 DL(psf): Gate Span(ft): Post Design Steel galvanized A-500 Section 'kind 2.5x2.5x14Ga 15764 5 5 0.85 A-36 Fb (psi) 21600 fb (psi)<Fb OK 16.2 Fv (psi) 14400 Rail to Posts Connection Design Actual Pullout 32 Allowable Pullou 200 Using 10-16 Hilti Kwik OK Flex Screw (Gate Span = Gate Leaf, not opening) MDR 4500 Top and Bottom Design 2x1x0.071 st galvanized A-500 Mmax. (lb -in) 4074 Mmax. (lb -in) Z• (in'3) fb (psi) Zx (in" 3) 0.155 16393 0.71 23089.1 fb (psi) Mmax/Sx Foundation Design (nonconstrained FBC 2017 -1807.3.2.1) P 583.83 A 2.16 d (Depth) 3.95 fb (psi) 26287 fb (psi)<Fb OK (2017 -1806.2) Lateral soil bearing Footing Diameter (ft) For poles 1806.3, 200 1.58333 2 NEXT POST FENCE TO BE AT NO MORE THAN 4' 2x1x16 GA. GALVANIZED STEEL FRAME GATE (TYP) GALVANIZED STEEL POST 2-1/2"x2-1/2' x14GA 24 GA. (MIN.) GALVANIZED METAL a0 SHEET FENCE HINGES TO RESIST 180 LBS 2x1x16 GA GALVANIZED STEEL FRAME GATE (TYP) /i • i0 3 KSI CONC, FOOTING 019'x4'-0" DEEP OR 024"x3'-9" DEEP OR 030"x3'-4" DEEP OR 036"x3.-0" DEEP 01T9 2x1x16 GA. GALVANIZED STEEL FRAME GATE (TYP) 2x1x16 GA. GALVANIZED STEEL FRAME GATE (TYP) 1011140 10'-0" (MAX) dik ! II I I 11 -t UI CANE BARS SOLID BAR GATE CONNECTIONS • PICKETS TO BE CONNECTED TO TOP AND BOTTOM RAILS WITH (4 PER PICKET, 2 TOP & 2 BOTTOM) 10-16 KWIK FLEX SCREW by HILTI OR APPROVED EQUAL. • AU. GATE FRAMES TO BE CONNECTED WITH 1/8" FILLET WELD ALL AROUND. TYP. DOUINE GAZE ELEV. VIEW SCALE: 1/2 -1.-0" 10'-0' MAX TYP. DOUBLE, GCE PIAN. VIEW 0.08 S=0.57 IN' Z=0.71 IN' Mmax=16 393 #-in M Aso=Mn/0 , Mn =Fy*Z 0 =1.61 M Aso=19 550 #-in Mmax < M Aso 4. 2 }. S=0.124 IN' Z=0.155 I Mmax=4 074 #-in M ASo=Mn/D Mn=Fy*Z , A =1.67 M Aso=4 269 #-in Mmax < M ASo 0.06 y. 4.1 2" 4' POSTS (14 GA) RAILS (16 GA) SCALE: 1/2"=1'-0' -�I NEXT POST FENCE TO BE AT NO MORE THAN 4' r 3 KSI CONC. FOOTING 019'x4'-0" DEEP OR 024"x3'-9' DEEP OR 030'x3'-4" DEEP OR 036"x3'-0" DEEP , (TYP) GALVANIZED STEEL POST 2)'x2)"x 14GA l `' 24 GA. (MIN.) GALVANIZED METAL SHEET FENCE Z=0.0074 I W Mmax= 1 6.2*(6.125/1 2)*2.42*2.42*0.125*1 2 =72 I -in M ASD=Mn/0 , Mn=Fy*Z , 0 =1.67 M Aso=160 #-in Mmax <MAso .110 6 i. N Tel. 786 9169 11 11 DRAMA R. LOPEZ,PE ❑GONZALO A. PAZ,PE 1(9(2018 SD-3 PICKETS (27 GA) 911