Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BPP-18-523 (2)
Miami Shores Viiiage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RESTRICTIVE COVENANT PROTECTIVE POOL ENCLOSURE KNOW ALL MEN BY THESE PRESENTS: WHEREAS, the undersigned \I YOM cc, ` Cat . P Y.4 is/are the fee simple owner(s) of the following described property situated and being in Miami Shores Village, Florida: Address: �SOI N e 3 Gkve 1`-‘'vaM', S\r'OcP-S) Whereas, the undersigned owner(s) UQ YQy Cj cmccP desire to utilize said Lot(s) as a single building site, and the undersigned owner(s) do(es) hereby declare and agree as follows: I. That the property will not be used in violation of any ordinances of Miami Shores Village or Miami -Dade County now in effect or hereinafter enacted. • • • • II. That the purpose of the covenant is to induce Miami Shores Village to:ssu�'a permitfora • pool where the required enclosure is not on the subject property where the pdol is located; III. That if any of our adjoining neighbors remove any portion of their fencg or�wa11, or if • • • • our/my property shall fail to meet code requirements for pool barriers, view,* owners will• immediately installs a protective enclosure to meet code requirements ydtll obtatil L • • permit for such fence. • • • • IV. That, I/we, as owner(s) hold Miami Shores Village harmless for any negligence or illjix)t : that results from not having the enclosure. • • •• V. If enclosure belongs to said property, I agree to maintain & or replace'said enclosun .: • the event that is damaged or removed by any case. • •• •. •• • •. • NOW, THEREOF, for good and valuable consideration, the undersigned do(es) hereby declare that he/she will not convey or cause to be conveyed the title to the above property without requiring the successor in title to abide by all terms and conditions set forth herein. FURTHER, the undersigned declare(s) that this covenant is intended and shall constitute a restrictive covenant concerning the use, enjoyment and title to the above property and shall constitute a covenant running with the land and shall be binding upon the undersigned, his/her successors and assigns and may o be released by Miami Shores Village, or its successors, in accordance of said Village then in effect. N & PRINT OWNER SIGN & PRINT I Hereby Certify that on this dI ersonally appeared before me V '-Q On') C^ R and has produced ID # -1-45-Co O cis identification and he/she acknowledge that he/she executed the foregoing, freely and voluntarily, for purposes there in expressed. SWORN TO AND SUBSCRIBED before me on this d day of `e f uct (L, 20 ' B (Revised 05/2209 ,•, ,111 <4;gr ;4:` Bonded Thru Notary Public Underwriters ANGELA BAEZ MY COMMISSION # GG 043212 EXPIRES: October 30, 2020 OTARY PUBLIC STATE OF FLORIDA CONTRACTO LOT: P11 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM EXISTING SYSTEM AND SYSTEM REPAIR EVALUATION V/9.oNk 0\ SCATfiA /AGENT : PERMIT # JOC.L>s s eel/ ` e /C. v/ce BLOCK : l r,Z SUBDIV : Q 5 D e/yA Y At I - TO BE COMPLETED BY FLORIDA REGISTERED ENGINEER, DEPARTMENT EMPLOYEE, SEPTIC TANK CONTRACTOR OR S. PLETE OTHER CERTIFIED PERSON. SIGN AND SEAL BELOW. OR NOTELZN�REL�-ARKS WH`-'MITTED jTEHElTANKSvMCAL3NOT BELCERTIFIEDLE ITEMS. COMPLETE TANK CERTIFIC EXISTING TANK INFORMATION [ qo Q ] GALLONS SEPTIC TANK / GPD ATU [ ] GALLONS SEPTIC TANK / GPD ATU ( ] GALLONS GREASE INTERCEPTOR ( ) GALLONS DOSING TANK LEGEND: LEGEND: LEGEND: LEGEND: V N KAi rt,./ A) MATERIAL: CO/`/ U('0' MATERIAL: MATERIAL:________ MATERIAL: BA FE LE D : [ Y 4 BAFFLED : (Y / N 1 # p0 PS: [ BY 'i'1[7L: I CERTIFY THAT THE LISTED TANKS WERE PUMPED ON / / AREFREE or OBSERVABLE THE VOL ' s. S SPE / FIED AS DETERMINED BY [ DIMENSIONS/FILLING/LEGEND 1, DEFECT . OR LE S , AND HAVE A [ SOLIDS DEFLECTION DEVICE / OUTLET FILTER DEVICE 1 =N TLL V J CJK--L✓f S' S D C l — L J Di-�E CENSED CONTRACTOR BUSINESS NAME SIGN EXISTING DRAINFIELD INFORMATION [ 36O SQUARE FEET PRIMARY DRAINFIELD SYSTEM NO. OF TRENCHES [ SQUARE FEET / SYSTEM NO. OF TRENCHES [ [ 1 ILLED t ] MOUND [ ] TYPE OF SYSTEM: [ 1 STANDARD [ ��ED [ 1 CONFIGURATION: [ ] TRENCH [ DESIGN: [ ] HEADER [ ] D-BOX [ GRAVITY SYSTEM ELEVATION OF BOTTOM OF DRAINFIELD IN RELATION TO EXISTING GRADE SYSTEM FAILURE AND REPAIR INFORMATION [ [ SITE CONDITIONS NATURE OF FAILURE: FAILURE SYMPTOM: 1 SYS'- GPD ESTIMATED SEWAGE FLOW T TYPE OF WASTE ] DIMENSIONS: ZO X v ] DIMENSIONS: X ] DOSED SYSTEM INCHES [ ABOVE / BELOW 1 DOMES [ J COMMERCIAL [ ] METERED WATER [ ] TABLE 1, 64E-6, FAC ( ) DRAINAGE STRUCTURES [ ] POOL [ ] PATIO / DECK [ ] PARKING : [ ] SLOPING PROPERTY [ ] [ ] HYDRAULIC OVERLOAD [ ] SOILS [ ] DRAINAGE / RUN OFF [ ] ROOTS [ ] WATER TABLE [ ] SEWAGE ON GROUND [ 1 TANK [ 1 D BOX/HEADER [ GRAINFIELD [ ] PLUMBING BACKUP [ ] [ ] MAINTENANCE [ 1 SYSTEM DAMAGE [ ] REMARKS/ADDITIONAL CRITERIA SUBMITTED BY: DH-4015, 08/09 Incorporated 6 Jo'- soletes previous editions which may not -6.001, FAC !,- ITLE/LICENSE DATE: be used) 7hg. Page 4 of 4 STATE OF FLORIDA - DEPARTMENT OF HEALTH APPLICATION FOR CONSTRUCTION PERMIT Permit Application Number PART II - SI:TEPLAN Scale: Each block re resents 10 feet and 1 inch = 40 feet. d► aai111 1111I11111111i11111I1-1N1-111I11I111111112©11111, 1:1I II1IN11 I ■ MI1 �ll��IN1111111t111iEl i 1 11lill�l RR111111IRIRIt W,rillarnallelli I Eill 1111111111111111 Notes: 900 G Alio") •74.� k 30.0 _Sy 4 %�rv.if✓ �`'e/c� Site Plan submitted by: Plan Approved By County Health Department ALL CHANGES MUST BE APPROVED BY THE COUNTY HEALTH DEPARTMENT DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC • Page 2 of 4 (Stock Number: 5744-002-4015-) . Not Approved Date nft o NOTE: ALL SHEETS MUST BE REVIEWED MIAMI-DADE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES Herbert S. Saffir Permitting and Inspection Center 11805 SW 26th Street (Coral Way) • Miami, Florida 33175-2474 • (786) 315-2000 APPLICATION FOR MUNICIPAL PERMIT APPLICANTS THAT REQUIRE PLAN REVIEW FROM MIAMI-DADE FIRE RESCUE AND/OR ENVIRONMENTAL SERVICES PROVIDE MUNICIPAL PROCESS NUMBER HERE LOCATION OF IMPROVEMENTS Job Address lo`3o\ 1.1 E -: N AA -Ye- CONTRACTOR INFORMATION Contractor No.5.-,_5.cv- cvtt•cRako FL. Last four (4) digits of Qualifier No. G1?G. NS?7 Folio l 1 2.2..3\ O V3c3c1-1 o Contractor Name VA CSws u s� C. t ��c.4na • Lot Block Qualifier Name ' Subdivision PBpg Address kg (I( L- W 5 o S i , Metes and bounds City :"•-‘ a es>... State -Zip 3B1 b D • TYPE OF IMPROVEMENTS [ ] New Construction on Vacant Land [ ] Iteration Interior [✓Alteration Exterior [ ] Relocation of Structure [ ] Enclosure [ ] Repair [ ]Repair Due to Fire ( ] Demolish [ ] Shell Only [ ] Addition Attached [ ] Addition Detached [ ] Re -Roof i ] Foundation Only [ ) Tent Current use of property 5 r • Description of Work {Jew +-s 1."--a5:1 L - _ " c.�s Sq.Ft.G� Units Floors Value of Work ' ZS .000 PERMIT TYPE l,1 MBLD* Category 55 REVIEW STATUS [ ] Chg. Contractor [ ] Re -Issue [ ] Re -Stamp [ ] Revision [ ] Not Applicable for Fire OWNER'S NAME Owner V�Qo1a�CA t" Address 1.c 5o\ 1J 'r3. 4Lie_ [ ] MELE City %-;, * TIZip 3'5135?' [ ] MPLU Phone `$ "vi3 c,. S g 3 [ ] MLPG Last four (4) digits of Owner's Social Security No. [ ] MMEC [ ] FIRE PERSON TO PICK UP PLANS / Name L- c L n 0..) iN fJ nT4=1 ARCHITECT / ENGINEER Owner Address Address \\Z t J u-N �"C** s \\ City State _ City lam_. NA —A. Stated LZip 3.\--. ^Zip Phone Phone 156c - q 9:5 - Q\�� FIRE SPECIAL REQUEST PLAN REVIEW (SRI) I am requesting a Special Request Plan Review (SRI) to be scheduled as soon as possible. There is a minimum charge of one -hour. Please contact the Fire Department for current rate. Date: 1' Request: Date: 2nd Request: Date: 3T'i Request: If the applicant is a known named violator with: unpaid civil penalties; unpaid administrative costs of hearing; unpaid County investigative, enforcement, testing, or monitoring costs; or unpaid liens, any or all of which are owed to Miami -Dade County pursuant to the provisions of the Code of Miami -Dade County, Florida, a hold on the review may be placed on this application. 123 01-192 5/17 Shores Village't Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 IJSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDI G PE IT APPLICATION,, BUILDING ❑ ELECTRIC ❑ ROOFING ®PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS JOB ADDRESS: / 050 V f •-e 3 lie MAR 0 1 2018 BC 20 i Master Permit No. -e? r S 2 Sub Permit No. ❑ REVISION ❑ EXTENSION ❑ CHANGE OF ❑ CANCELLATION CONTRACTOR ❑ RENEWAL ❑ SHOP DRAWINGS City: Miami Shores County: Folio/Parcel#: ���c�7j 1 i 1 31).Q Occupancy Type:l��e5 CJ t'A:I Construction Type: Miami Dade Zip: Ist a Building Historically Designated: Yes NO (tA Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): ron I C i E C G d`e o C\ Address: I DEG .t 3 a ve City: IL-'i ► et ( S State: + 1 (? r l d Tenant/Lessee Name: Phone#: '31 5 Ci Zip: 33.i 38 Phone#: Email: " (1Y7 l(15 bi Sp (0 - l ' corn CONTRACTOR: Company Name: 0,,n 1 I'71iYlii l�' irEtD (o CJC Phone#: <-x%J -- �� Y O Address: (O IL( rt)Li) State:1 at City: H. (A it-�l! ] Zip: n Qualifier Name: Yl P P{�j( (Pall vl 'Lz Phone#: 3"/ State Certification or Registration #r l , 1 `7 5:-/ IXD(E5 Certificate of Competency #: DESIGNER: Architect/Engineer: Address: 1 LI D5S ago 0-0 Atov-tc Evicos Value of Work for this Permit: $ J Phone#: City: � \ 1C� `fit Stater _I Zip ?SDI Square/Linear Footage of Work: d‘CO „Type of Work: ❑ Addition ❑ Alteration New ❑ Repair/Replace ❑ Demolition Description of Work: -e"L-SiD SU..Y i IYWr' I nO\_ ri' d) pC\ C . V K ` 1,Q ( - A Jade -- Specify color of color thru tile: Submittal Fee $ Permit Fee $ Scanning'Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ CCF $ CO/CC $ DBPR $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) Date Miami Shores Village Building Department 10050 N.E.2r.d Avenue Miami Shores: Fioriria 33i 38 Tel: (305) 795.2204 Fax: (3C5) .156.8072 \ SWIMMING POOL OWNER'S CERTIFICATION O� 1 2011) Miami Shores Village Building & Zoning Department Attention: Building Official I certify that I am the legal owner of the property described as 0 , located at 1 C) 0 t cx\J P M.'r S\res - In accordance with Section 33-12(f), Code of Metropolitan Dade County, I certify that I understand and agree that the swimming pool to be constructed at the above address cannot be used or filled with water until separate permit has been obtained for an approved safety barrier, and such barrier erected, inspected and approved. further understand that this certification, however, does not eliminate the need for obtaining a permit and erecting and approved barrier prior to final inspection and use of the pool. Legal Owner Note: This certification is to be submitted with a swimming pool permit application in duplicate. Jliami Shores Building Depnrt'rnerit•.: 10050 NEE, rtd Avenue• Miami Shores, Ftailda 33138' . Tel: (1057795.220r • Fax: /56.89W • SWIMMING POOL OWNER'S CERTIFICATION Date \ a (20 I Miami Shores Village Building & Zoning Department Attention: Building Official • • • • . • . • . • • • • • • •• •• • • • • • • • •• •• • I certify that I am the legal owner of the property described as `TDVic) 4 11 01303q, 0 , located at t Qe (Q f e k`-A\ a \^(ce5 - In accordance with Section 33-12(f), Code of Metropolitan Dade County, I certify that I understand and agree that the swimming pool to be constructed at the above address cannot be used or filled with water until separate permit has been obtained for an approved safety barrier, and such barrier erected, inspected and approved. I further understand that this certification, however, does not eliminate the need for obtaining a permit and erecting and approved barrier prior to final inspection and use of the pool. Legal Owner Note: This certification is to be submitted with a swimming pool permit application in duplicate. Phone: (305) 552-7504 Fax: (305) 229-8068 E-mail: enpav@yahoo.es ILEoLiru L—JO LI PROFESSIONAL LAND SURVEYOR & MAPPER 14317 SW 45th Terrace Miami, FL. 33175 PROPERTY ADDRESS: 10501 NE 3rd Ave. Miami Shores, FL. 33138 LEGAL DESCRIPTION: Lot 18 and the South %2 of Lot 17, Block 12, of FIRST ADDITION TO PASADENA .-PARK, according to the plat thereof as recorded in Plat Book 6, at Page 82, of the Public Records of Miami Dade County, Florida LOT- 2 BLOCK- 12 0 O Fd. 1/7' I.P. 4' 4.5. Wall 75.00' LOT- 1 BLOCK- 12 U 0 Fd. 1 /7' I.P. • • • • SKETCH'©F4URV'EY•:• • • ('Boundary lurveyl • • • SCAL'E.1"= 20' • ••. • • • • • • • • •• •• • • • • • ▪ i 4.10 • • 4' C.B.S. Wall Remainder of LOT- 17 BLOCK- 12 4' C.B.S. Wall Fd. 1 /7' I.P. ONE STORY Res.# 10501 F.F.Elev.: 12.26' 15.5' Asphalt Pavement 40' TOTAL R/W NOTE: Elevations are referred to Miami Dade County BM# D-159 Elev.= 10.32' OF N.G.V.D. of 1929 • • •• • • • • BASED ON THE FLOOD INSURANCE RATE MAP OF THE FEDERAL EMERGENCY AGENCY REVISED ON 9-11-09 THE HEREIN DESCRIBED PROPERTY IS SITUATED WITHIN: ZONE X BASE FLOOD ELEV. N/A COMMUNITY NUMBER: 120652 PANEL NUMBER 0302 SUFFIX L LEGAL NOTES THIS SURVEY DOES NOT REFLECT OR DETERMINE OWNERSHIP. EXAMINATION OF THE ABSTRACT OF TITLE IMLL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY, AFFECTING THE PROPERTY. THIS SURVEY IS SUBJECT TO DEDICATION, LIMITATIONS, RESTRICTIONS, RESERVATIONS OR EASEMENTS OF RECORDS. LEGAL DESCRIPTION PROVIDED BY CLIENT. THE LIABILITY OF THIS SURVEY IS LIMITED TO THE COST OF THE SURVEY. UNDERGROUND ENCROACHMENTS, IF ANY, ARE NOT SHOWN. THIS FIRM HAS NOT ATTEMPTED TO LOCATE FOOTING AND/OR FOUNDATIONS AND/OR UNDERGROUND IMPROVEMENTS OF ANY NATURE. IF SHOWN BEARINGS ARE REFERRED TO AN ASSUMED MERIDIAN. IF SHOWN ELEVATIONS ARE REFERRED TO N.G.V.D. OF 1929 THE CLOSURE IN THE BOUNDARY SURVEY IS ABOVE 1: 10000 A= ARC DISTANCE AC= AIR CONDITIONED UNIT B.C.= BLOCK CORNER C.B.= CATCH BASIN (C)= CALCULATED CL.= CLEAR C.L.F.= CHAIN LINK FENCE CONC.= CONCRETE D.M.E.= DRAINAGE MAINT. EASEMENT ENC.= ENCROACHMENT FD.= FOUND I.F.= IRON FENCE (M)= MEASURED M/L= MONUMENT LINE DATE OF FIELD WORK: Dec. 15, 2017 REVISED ON: I hereby certify that the attached Skelc1T of Survey of the herein described property is to the best of myfkno1Tedge•ilnd belief, a We and correct representations of a field sickly pa06nne(,uhder my direction. And also, meets.the Minimum TbohnE I' 9nda`fds as set forth by (he'Florida.Board 'of 1drofesston4l`Su veycis Mappers'in chapter 5J-17:05611m 5J-1 .152`F;A:C tfurstkata to r 472.027 • ARTUiib R TOIRAC P S M 3t02` v\lmt�. t Not valid without the rI ne sod irk onginal efied Sseahof a^. Florida Lfcefllsed;Survetu yor and Mappers., /+' ; LEGEND AND ABBRE, tQTIb J$ s.-�f O.H.= OVERHEAD UTILITIES. -` '•' �i i a(W, 1,IG}'IT-OF'WAY P-C-P-= PERMANENT. CONTROL'PQI1 T7:...,TYP:`1TYPICAL`,' P.O.B.= POINT OF BEGINNING -:->.;,'..t. •-;1 UU.E=-UTILITY EASEMENT P.O.C.= POINT OF COMMENCE ! I 1 1 }'; 1N I' WOOD FENCE R= RADIUS ` 1 - I .W.M.= WATER METER (R)= RECORD p= DIAMETER RES.= RESIDENCE 1= CENTER LINE ® = WATER METER Cu)'�"= POWER POLE "T = LIGHT POLE CERTIFIED TO: Veronica Scatena JOB No. 171230 k0 °O= ELEVATION = CATCH BASIN O = SANITARY SEWER w DQ = WATER VALVE ® = TV BOX • U.S. DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. • OMB No:1660.0008 ' • • • •' Expiration Q e:Novemtter 304 2018 • • • • • • Job Ntjfit' br• 17123L1.. • ••••• •••• 000000 • •••••• • . •• ••••.• 00000 Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/con�ptari ,wand (3) bOikj 11owner ' SECTION A — PROPERTY INFORMATION FOR INStAl!APICE COMP14ITY USE" Al. Building Owner's Name VERONICA SCATENA Policy Number •, • '••••• • A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 10501 NE 3 AVENUE Company NAIL Numb t:•, • ' City State ZIP Code MIAMI SHORES FL 33138 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) LOT 18 & S 1/2 OF LOT 17, BLOCK 12, FIRST ADD TO PASADENA PARK, PLAT BOOK 6, PAGE 82 A4. Building Use (e.g., A5. Latitude/Longitude: 'A6. Attach at least A7. Building Diagram A8. For a budding a) Square footage b) Number of c) Total net area d) Engineered A9. For a building with a) Square footage b) Number of permanent c) 'Total net area d) Engineered Residential, Non -Residential, Addition, Accessory, etc.) Lat. 25°52'18.42"N Long. 80°1 1'28.21"W RESIDENTIAL Horizontal Datum: obtain flood insurance. 1.0 foot above above adjacent adjacent grade ■ NAD 1927 grade Ti NAD 1983 9 2 photographs of the building if the Number 8 Certificate is being used to 1301.2 sq ft with a crawtspace of crawtspace permanent flood of flood openings flood openings? an attached of attached flood of flood openings flood openings? or enclosure(s): or enclosures) openings in the crawtspace in A8.b 1108.0 sq or enclosure(s) within in sq ft within 1.0 foot sq in N/A ' ❑ Yes ❑ No garage: garage N/A openings in the attached garage in A9.b N/A ❑ Yes ® No SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number VILLAGE OF MIAMI SHORES 120652 B2. County Name MIAMI - DADE B3. State FL 64. Map/Panel Number 12086C 0302 B5. Suffix L B6. FIRM Index Date 09-11-09 B7. F RM Panel Effective/ Revised DateFlood 09-11-09 B8. Flood Zone(s) X B9. Base Flood Elevation(s) Zone AO, use Base Depth) N/A B10. Indicate the source of the Base Flood Elevation (BFE) ❑ Community Determined for BFE in Item 69: Coastal Barrier Resources ❑ CBRS data ® NGVD System or base flood depth entered in Item B9: ❑ Other/Source: • FIS Profile B11. Indicate elevation B12. Is the building Designation Date: j FIRM datum used located in a N/A 1929 ❑ NAVD 1988 ❑ Other/Source: (CBRS) area or Otherwise Protected ❑ OPA Area (OPA)? III Yes • No • • • • • • FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 1 of 6 ELEVATION CERTIFICATE •.•. OMB No. 1 660-0008 ' . • • Expiration DatL: Clovemb er 30; 2018 • IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INS t:ME COMPt4 CUSE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 10501 NE 3 AVENUE• Policy Nti . b� ' •••• ' City State ZIP Code MIAMI SHORES FL 33138 Company.NAIC.Numbe . • • • • • • • • • ' • • - SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) • : • •• Cl. Building elevations are based on: ❑Construction Drawings' ❑ Building Under Construction* kj Sinished Construction . - 'A new Elevation Certificate will be required when construction of the building is complete. • .... • • C2. Elevations — Zones A1—A30, AE, AH, A (with BFE), VE, V1—V30, V (with BFE), AR, AR/A, AR/AE, AR/A1—A30, AR/AH, AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: # D-159 ELEV= 10.32' Vertical Datum: NGVD 1929 Indicate 01 elevation datum NGVD 1929 used ■ for the elevations in items a) through h) below. NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 10 05 ® the measurement used. feet ❑ meters b) Top of the next higher floor 12 26 11 feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A ® feet " ❑ meters d) Attached garage (top of slab) N/A i i feet ❑ meters - e) Lowest elevation of machinery or equipment servicing the building 10 13 10 feet ❑ meters (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 10 05 1::1 feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 10. 08 ® feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including N/A . m feet ❑ meters structural support SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect I certify that the information on this Certificate represents my best efforts to interpret statement may be punishable by fine or imprisonment under 18 U.S. Code, Section Were latitude and longitude in Section A provided by a licensed land surveyor? ® authorized by law to certify elevation information. the data available. I understand that any false 1001. Yes ❑ No ❑ Check here if attachments. Certifier's Name License Number ARTURO R. TOIRAC 3102 Place Seal Here 3 /p ..2-- /.2 _ / —/ Title PROFESSIONAL LAND SURVEYOR AND MAPPER Company Name Address 14317 SW 45th TERRACE City State ZIP Code MIAMI FL 33175 Signature Date Telephone "=ed-ezt� DIC. 15, 2017 (305) 552 7504 Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) CROWN OF ROAD ELEV. = 10.44' LOWEST MACHINERY ON C2 e IS A/C ELEVATION LOCATED AT NORTH SIDE - LAT / LONG OBTANIED BY GPS •..... • • ..... •••• • •••. • • • FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6 ELEVATION CERTIFICATE IMPORTANT: In these spaces, copy the corresponding Information from Section A. FOR INSORANCE COMPANY USE . Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 10501 NE 3 AVENUE Policy Nube�:. • ••••• • • • City State ZIP Code MIAMI SHORES FL 33138 - ComparoptIAIG Numbej ... • • • • • • ' •• • SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIREf3 .: • FOR ZONE AO AND ZONE A (WITHOUT BFE) • ;•.. . • ., For Zones AO and A (without BFE), complete Items El-E5. If the Certificate is intended to support a LOMA ord,r3MR-F requp$t,. _complete Sections A, Band C. For Items El-E4, use natural grade, if available. Check the measurement used. in Puerto Rliiil enly, enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, : I . crawlspace, or enclosure) is ❑ feet ■ meters ■ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawispace, or enclosure) is ❑ feet ❑ meters ❑ above or ■ below the LAG. 9 (see pages 1-2 of Instructions), ❑ above or ❑ below the HAG. 0 above or 0 below the HAG. ❑ above or 0 below the HAG. with the community's this information in Section G. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters E3. Attached garage (top of slab) is ❑ feet 0 meters E4. Top of platform of machinery and/or equipment servicing the building is 0 feet • meters E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance floodptain management ordinance? ❑ Yes ❑ No ■ Unknown. The local official must certify SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's'authorized representative who completes Sections A, B, and E for Zone A (without a FEMA-issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments • ❑ Check here if attachments. - ••.. OMB No.•1660.0008 '.. • Expiration Da?e: November 30, 2018 .... • • • .•.. • •••• • .••• •.•• •••• • SS., • FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 3 of 6 ELEVATION CERTIFICATE IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INIS JFW CE COMPANY USE• Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 10501 NE 3 AVENUE Policy Nyrphr: ;, •..•• ' City State ZIP Code MIAMI SHORES FL 33138 Compat►9rhME Number • • • •• • • • ' ' •• • .. .. SECTION G — COMMUNITY INFORMATION (OPTIONAL) • . • • • • - The local official who is authorized by law or ordinance Sections A, B, C (or E), and G of this Elevation - used in Items G8—G10. In Puerto Rico only, enter GI. ❑ The information in Section C was taken engineer, or architect who is authorized data in the Comments area below.) • to administer the community's floodplain management ordinance an complete Certificate. Complete the applicable item(s) and sign below. C1i%ck the merurement meters. • • • from other documentation that has been signed and sealed by a licensed surveyor, by law to certify elevation information. (Indicate the source and date of the elevation E for a building located in Zone A (without a FEMA-issued or community -issued BFE) is provided for community floodplain management purposes. -• • .• G2 ■ A community official completed Section or Zone AO. G3. ❑ The following information (Items G4--G10) G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ G8. Elevation of as -built lowest floor (including of the building: G9. BFE or (in Zone AO) depth of flooding at the G10. Community's design flood elevation: New Construction 0 Substantial Improvement basement) El • meters Datum building site: ■ feet ❑ feet ■ meters Datum ❑ meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments (including type of equipment and location, per C2(e), if applicable) ❑ Check here if attachments. ••.. OMB No.' 16§Q-9008 ' • • • . Expiration•Datei November 3Q, 2018 •' • •••. • • • .. • • •.• •••. • • • •.•. • .•. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 4 of 6 • ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS See Instructions for Item A6. IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSt9f;RIdCE COMP•NSY USE. 4 Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Idrribei' 10501 NE 3 AVENUE ..••. • City State ZIP Code ComparlyMIG Numbgr ...-.------6-;.. MIAMI SHORES FL 33138 •• •• • • •• • . . --s.••.• • • • . If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs bell v accerdin to the.. instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View"; and, if regtred, "Right Srcfe Vin" and, "Left Side View." When applicable, photographs must show the foundation with representative example of the flood ppepings or: • -vents, as indicated in Section AO. If submitting more photographs than will fit on this page, use the Continuation Page. • • • • • • • Photo One Caption FRONT VIEW DIC. 15, 2017 aqW 's'.. `, +��� tr r•, t. t• 1 p ,r..r...... Photo Two Caption REAR VIEW DIC. 15, 2017 OMB No. 166Q-0008 •• ExpiratidWitei Novemter'10, 2018• • • •' • • • • • • • ••. • • .•. ••. • • • ..• • •.. • FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 5 of 6 FORM NO. P66-765 REV. 10 Supersedes Form No. P66-765 Rev. 9 13P*A SERIES *J, C, D IMPORTANT: This product is shipped with a nitrogen holding charge that must be vented prior to evacuation and charging. This product is only intended for condensing change -au': in existing R-22 systems. New R-22 system installations are prohibited by EPA. This product must be charged with R-22 refrigerant meeting AHRI 700 purity standard. WEATHER irmzgr 13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced alu- minum fins. • Strong, attractive cabinet —louvered design protects the coil from damage. . • • • • Expansion Valves with Internal Check Va170,-.-Wrides for quieter refrigerant meterir7g.. • Demand Defrost Control • Non -Cycling Reversing Valve, • Hot Gas Muffler . • • • . . • .. • • • Service Valves • • • • ••••. • Grille/motor mount for quiet ff9nopetiation. . • ■ Easily accessible control box • • • • • • • Certified and rated under AF qar lard 240. • • U.L listed. ' • Accessories/Options': • • • • • •• •• • •• • • Low Ambient Control (Model No. RXPZ-00'14 • • • • • Outdoor Thermostats (Model No. RXPT-A01, A02, A03 or A04) • Heat Pump Monitor (Model No. RXPM-B01) • Thermostats and Subbases (Available through the PROSTOCK1' department) • Compressor Time Delay Control (Model No. RXMD-B01) • Blower Time Delay Control (Model No. RXMD-004) RXMD-004 is not required if the outdoor unit is matched with a WeatherKing furnace or air handler, or if the furnace or air handler used has a blower off time delay built-in. • Sound Enclosure* • High Pressure Control (Model No. RXAB-A03) • Bi-Directional Filter Drier* ■ Start Components* *Available through the PROSTOCK' department. Applications WeatherKing remote heat pumps offer comfort and dependability for single, multi -family and light commercial applications. LISTED US •.,••• • • • • • ■ • ••!.•. • •• .• ▪ . ..• •• •• • • • • • .• • • • Model Identification Number 13 P J 13 SEER P = HEAT PUMP VOLTAGE J = 208-230 SINGLE PHASE C = 3-60-208/230 THREE PHASE D = 3-60-460 THREE PHASE A DESIGN SERIES A = 1ST DESIGN 18 C 01 NOMINAL COOLING CAPACITY CABINET WEATHERKING 18=18,000 BTU/HR [5.28 kW] 24 = 24,000 BTU/HR [7.03 kW] 30 = 30,000 BTU/HR [8.79 kW] 36 = 36,000 BTU/HR [10.55 kW] 42 = 42,000 BTU/HR [12.31 kW] 48 = 48,000 BTU/HR [14.07 kW] 60 = 60,000 BTU/HR [17.58 kW] MINOR DESIGN SERIES Performance Data AHRI Standard Conditions - Single Phase Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. Model Numbers AHRI Cooling Performance AHRI Heating Performance (70°F I21°C Indoor) 80°F 126.5°CI DB/67°F (19.5°C] WB Indoor Air 95°F [35°CI DB Outdoor Air Outdoor Air 47°F [B.5°Cl DB/ 43°F (6°C) WB DOE High Temp. Outdoor Air 17°F [-8.5°CI DB/ 15°F [-9.5°CI WB DOE Low Temp. DOE Region iv HSPF Outdoor Unit 13PJA Indoor Coll and/or Air Handler Total Capacity BTU/H [kW) Net Sens. BTU/H IkW] Net Latent BTU/H [kW] EER SEER Snd. Rate dB Indoor CFM IL/sl BTU/H [kWI coP BTU/H um COP Rev. 5/9/11 18 RHSA HM1817 RCSA H`2417A* i0 ( ) 18 000 [5.3] 13,100 [3.8] 4,900 [1.4J 11.95 13.00 76 600 [283] 15,900 [4.7] 3.46 8 500 [25] 2.26 7.7 24 RHSA-HM2417(RCSA-H*2417A*) O 23,800 [7.0] 17,300 [5.1] 6,500 [1.9] 12.00 13.00 74 800 [378] 20,800 [6.1] 3 40 11,000 [3.2] 2.06 •• • • 7.7 • 30 RHSA-HM3017(RCSA-H*3617A*) O 28 600 [8.4] 21,200 [6.2] 7,400 [2.2] 11.70 13.00 73 1 000 [4721 27,600 [8.1] 360 .• f��,,700 [�•61 2 1� • • • •7 7 • 36 RHSA-HM3617(RCSA-W'3617A*) p 35,400 [10566] 25,900 9,500 11.55 13.00 75 1,200 36,600 [10.7] 3•5• • iiy200 ;At • •:7 7 42 RHSA HM4221(RCSA H*4821A*) C 41,000 [12.0] 29,700 [8.7] 11,300 [3.3] 11.20 13.00 77 1,400 [661] 40,000 [11.7] • 46• • • g3,800 • _[e'.0] • 4•.. 2160 • . •7.7 • •7 7 . 48 RHLA-HM4821(RCSA-H*4821A*) O 48,000 [14.1] 35,100 [10.3] 12,900 [3.8] . 1155 13.00 77 1,525 [720] 44,000 [12.9] 3156. • 000 • jP.2] 60 RHLA-HM6024(RCSA-H*6024A*)O 58,500 [17.1] 42,300 [12.4] 16,200 [4.7] 11.80 13.00 77 1,825 [861] 54,500 [16.0] 33 600 ;�•;•);9.8] . • 2.60. 7.7 i ) Highest sales volume tested combination required by D.O.E. test procedures. • • • • • •• • Performance Data AHRI Standard Conditions -Three Phase 208/230V Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. • • •• • • • • •• • • • • • Model Numbers AHRI Cooling Performance AHRI Heating Performance (70°F I21°C1 Indoor) 80°F I26.5°CI DB/67°F I19.5°C] WB Indoor Air 95°F [35°C1 DB Outdoor Air Outdoor Air 47°F 18.5°C1 DB/ 43°F [6°C] WB DOE High Temp. Outdoor Air 17°F [-8.5°C1 DB/ 15°F[-9.5°CI WB DOE Low Temp. DOE Region iv HSPF Outdoor Unit 13PCA Indoor Coil and/or Air Handler Total Capacity BTU/H (kW] Net Sens. BTU/H [kW] Net Latent BTU/H [kW] EER SEER Snd. Rate dB Indoor CFM IL/s1 BTU/H [kW] COP BTU/H I1(W1 COP Rev. 5/9/11 342 RHSA-HM3617(RCSA-H*3617A*) i0 [10 4] 2[7 6] 9,500 11.55 13.00 76 [566] 36,600 3.50 21,200 2.44 7.7 RHSA-HM4221(RCSA-H*4821A*) O 41,000 [12.0] 29,700 [8.7] 11,300 [3.3] 11 20 13.00 77 1,400 [661] 40,000 [11.7] 3 52 23,800 [7.0] 2 24 7 7 48 RHLA-HM4821(RCSA-H*4821A*) O 48,000 [14.1] 35,100 [10.3] 12,900 [3.8] 11.55 13.00 77 1,525 [720] 44,000 [12.9] 3.56 28,000 [8.2] 2.50 7.7 60 RHLA-HM6024(RCSA-H*6024A*) O 58,500 [17.1] 42,300 [12.4] 16,200 [4.7] 11.80 13.00 77 1,825 [861] 54,500 [16.0] 3 76 33,600 [9.8] 2.60 7.7 Highest sales volume tested combination required by D.O.E. test procedures. ( ] Designates Metric Conversions 2 WeatherKing Performance Data AHRI Standard Conditions -Three Phase 460V Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used. Model Numbers AHRI Cooling Performance AHRI Heating Perlormance (70°F l21°C Indoor) 80°F [26.5°C] DB/67°F 119.5°C1 WB Indoor Air 95°F [35°C] DB Outdoor Air Outdoor Air 47°F 18.5°C] DB/ 43°F 16°C] WB DOE High Temp. Outdoor Alr 17°F [-8.5°C] DB/ 15°F [-9.5°CI WB DOE Low Temp. DOE Region IV HSPF Outdoor Unit 13PDA Indoor Coil and/or Alr Handler Total Capacity BTU/H [kW] Net Sens. BTU/H [kW] Net Latent BTU/H [kW1 EER SEER Snd. Rate d8 Indoor CFM [L/s] gTU/H [kW] COP BTU/H [kW] COP Rev. 5/9/11 36 RHSA HM3617(RCSA H"3617A") 35,400 [10.4] 25,900 [7.6] 9,500 [2.8] 11.55 13.00 75 1 200 [566] 36,600 [10.7j 3.50 1,20 21 200 2.44 7.7 42 RHSA-HM4221(RCSA-H*4821A*) �- 41,000 [12.0] 29,700 [8.7] 11,300 [3.3] 11 20 13.00 77 1,400 [661] 40,000 [11.7] 3 52 23,800 [7.0] 2 24 7 7 48 RHLA-HM4821(RCSA-H*4821A*) OO 48,0001 35,100 10 3] 1[23 8] 11.55 13.00 77 1,5257 44,000 2 9] 3.56 28,000 [8 2] 2.50 7.7 60 RHLA-HM6024(RCSA-H*6024A*)C� [171) 42,300 16,200 11.80 13.00 77 [861] [160] 3.76 3[9$1° 2.60 7.7 it. Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • • • • • • • • • • • • • • • • • •• •• • • • • • • • •• • • • • • • . • • • • • • • • • • • • • •• • • • • •• • • • • • • WeatherKing 3 Electrical and Physical Data - Single Phase Model Number 13PJA ELECTRICAL PHYSICAL phase . Frequency (Hz) Voltage (Volts) Compressor Fan Motor Full Load Amperes (FLA) Minimum Circuit Ampacity Amperes Fuse or HACR Circuit Breaker Outdoor Coil Refrig. Per Circuit Oz. [g] Weight Rated Load Amperes (RLA) Locked Rotor Amperes (LRA) Minimum Amperes Maximum Amperes Face Area Sq. Ft. [m2] Na. Rows CFM [Us] Net Lbs. [kg] Shipping Lbs. [kg] Rev. 5/9/2011 18 1-60-208/230 9/9 41 0.6 12/12 15/15 20/20 11.06 [1.03] 1 1700 [802] 81 [2296] 142 [64.4] 150 [64.4] 24 1-60-208/230 14.1/14.1 54 0.8 19/19 25/25 30/30 13.72 [1.27] 1 2370 [1118] 99 [2807] 180 [81.6] 190 [81.6] 30 1-60-208/230 14.6/14.6 67 0.8 20/20 25/25 30/30 16.39 [1.52] 1 2800 [1321] 115 [3260] 210 [95.3] 222 [95.3] 36 1-60-208/230 18/18 83 1.2 24/24 30/30 40/40 21.85 [2.03] 1 3575 [1687] 134 [3799] 210.5 [95.5] 222.5 [95.5] 42 1-60-208/230 19.2/19.2 105 1.2 26/26 35/35 40/40 21.85 [2.03] 1 3575 [1687] 150 [4252] 201.5 [91.4] 213.5 [91.4] 48 1-60-208/230 26.1/26.1 137 1.2 34/34 45/45 50/50 21.85 [2.03] 1 3575 [1687] 154 [4366] 215 [97.5] 227 [97.5] 60 1-60-203/230 25.3/25.3 150 1.2 33/33 40/40 50/50 21.85 [2.03] 2 3365 [1588] 256 [7258] 275.5 [125] 287.5 [125] Electrical and Physical Data -Three Phase 208/230V Model 13PCA' ELECTRICAL PHYSICAL Phase Frequency (Hz) Voltage (Volts) Compressor Fan Motor Full Load Amperes (FLA) Minimum Circuit Ampacity Amperes Fuse or HACR Circuit Breaker Outdoor Coil Refrig. Per Circuit Oz. [pi Weight Rated Load Amperes (RLA) Locked Rotor Amperes (LRA) Minimum Amperes Maximum Amperes Face Area Sq. Ft. [m2] No. Rows CFM [Usl Net Lbs. [kg] Shipping Lbs. [kg] Rev. • • •• •••• :20 [99.8j • 228 • (99.8] 36 3-60-208/230 10.4/10.4 77 1.2 15/15 20/20 20/20 21.85 [2.03] 1 3575 [1687] 134"[M13] 42 3-60-208/230 13.5/13.5 89 1.2 19/19 25/25 30/30 21.85 [2.03] 1 3575 [1687] 150 [A1521212 [96:2J.224: [96.2] 48 3-60-208/230 16/16 115 1.2 22/22 30/30 35/35 21.85 [2.03] 1 3575 [1687] 15411 .215 [97.5] 227 [97.5] 60 3-60-208/230 17.3/17.3 123 1.2 23/23 30/30 40/40 21.85 [2.03] 2 3365 [1588] 2561,718 277 [125.6]•188 [125.6] Electrical and Physical Data -Three Phase 460V • • • • • • •• •• • • • • • • • • • • • • •• • • Model NumberDA ELECTRICAL PHYSICAL • • • Phase Frequency (Hz) Voltage (Volts) Compressor Fan Motor .Full Load Amperes (FLA) Minimum Circuit Ampacity Amperes Fuse or HACR Circuit Breaker Outdoor Coil Aefrip.� • . Pir •• Circuit Oz. [9I • �g I g� t • • Rated Load Amperes (RLA) Locked Rotor Amperes (LRA) Minimum Amperes Maximum Amperes Face Area Sq. Ft. [m21 No. Rows CFM [US] Net • • Lbs. [kg] Shipping Lbs. [kg1 Rev. 5/9/2011 36 3-60-460 5.8 45 0.6 8 15 15 21.85 [2.03] 1 3575 [1687] 134 [3799] 220 [99.8] 228 [99.8) 42 3-60-460 6.4 45 0.6 9 15 15 21.85 [2.03] 1 3575 [1687] 150 [4252] 202 [91.6] 214 [91.6] . 48 3-60-460 7.7 50 0.6 11 15 15 21.85 [2.03] 1 3575 [1687] 154 [4366] 215 197.5] 227 [97.5] 60 3-60-460 8.4 70 0.6 12 15 15 21.85 [2.03] 2 3365 [1588] 256 [7258] 276 [125.2] 288 [125.2] - NOTE: Refrigerant charge shown is for 15 feet of standard line set. Units are shipped with a nitrogen holding charge and must be charged with R-22 in the field. [ ] Designates Metric Conversions BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. GENERAL TERMS OF LIMITED WARRANTY WeatherKing will furnish a replacement for any part of this Parts Five (5) Years product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer. 4 WeatherKing Unit Dimensions LOW VOLTAGE 7/e" [22 mm) HOLE DIAMETER SERVICE FITTING BASE PAD (CONCRETE OR OTHER SUITABLE MATERIAL) HIGH VOLTAGE 111/82" [34 mm) HOLE DIAMETER SERVICE FITTING BASERAIL* "21/2-5 TON MODELS USE COMMON A DRAWN BASEPAN INSTEAD SERVICE PORT LIQUID LINE OF BASERAILS. THE DRAWN CONNECTION VAPOR LINE BASEPAN HEIGHT IS 31/8" [79.3 mm]. CONNECTION ELEVATION ABOVE ANTICIPATED SNOW IS NECESSARY • . • • . •. . • •... •••• • • • • • • • • . . • .• .. ••.. • • • • • • • • • • • • • • .• .. • • • • • • • • • • •• • • • • • • • •• . •. • • • . •. • DETAIL A Model Number 13P*A Height "H" (Inches) [mm) Length "L" (Inches) [mm) Width "W" (Inches) [mm) 18 261/4 [666.75] 235/8 [600.07] 235/8 [600.07] 24 261/4 [666.75] 275/8 [701.67] 275/8 [701.67] 30 273/8 [695.33] 315/8 [803.27] 315/8 [803.27] 36/42/48/60 353/8 [898.53] 315/8 [803.27] 315/8 [803.27] [ j Designates Metric Conversions .•• • • • • • • � • • WeatherKing 5 Heat Pump Refrigerant Line Size Information System Capacity Liquid Line Connection Size (Inch I.D.) [mm] Line Size (Inch O.D.) (mm] Liquid Line Size (R-22) Outdoor Unit Above or Below Indoor Coil (Heat Pumps Only) Total Equivalent Length -Feel Im] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [38.101 150 [45.721 Maximum Vertical Separation -Feel [m] 11/2 Ton 3/8" [9.53] 1/4 [6.35] 21 [6.40] 8 [2.44] N/A N/A N/A N/A 5/16 [7,94] 25 [7.62] 27 [8.23] 24 [7.32] 21 [6.40] 17 [5.18] 14 [4.27] 3/8* [9.53] 25 [7.62] 40 [12.19] 39 [11.89] 38 [11.58] 37 [11.28] 35 [10.67] 2 Ton 3/8 [9.53] 1/4 [6.35] 16 [4.88] N/A N/A N/A N/A N/A 5/16 [7.94] 25 [7.62] 26 [7.92] 21 [6.40] 15 [4.57] 10 [3.05] 5 [1.52] 3/8' [9.53] 25 [7.62] 38 [11.58] 36 [10.97] 35 [10.67] 33 [10.06] 31 [9.45] 21/2 Ton [9.5.5 3] 1/4 [6.35] 0 N/A N/A N/A N/A N/A 5/16 [7.94] 25 [7.62] 17 [5.18] 8 [2.44] 0 N/A N/A 3/8* [9.53] 25 [7.62] 37 [11.28] 34 [10.36] 31 [9.45] 29 [8.84] 26 [7.92] 3 Ton 3/8' [9.53] 5/16 [7.94] 25 [7.62] 15 [4.57] 4 [1.22] N/A N/A N/A 3/8* [9.53] 25 [7.62] 30 [9.14] 26 [7.92] 23 [7.01] 19 [5.79] 16 [4.88] 31/2 Ton 3/8' [9.53] 5/16 [7.94] 25 [7.62] 17 [5.18] 2 [0.61] N/A N/A N/A 3/8* [9.53] 25 [7.62] 37 [11.28] 32 [9.75] 28 [8.53] 23 [7.01] 18 [5.49] 4 Tor. 3/8' 19.531 3/8* [9.53] 25 [7.62] 33 [10.06] 27 [8.23] 21 [6.40] 15 [4.57] 9 [2.74] 1/2 [12.7] 25 [7.62] 43 [13.11] 42 [12.80] 40 [12.19] 39 [11.89] 38 [11.58] 5 Ton 3/8' [9.53] 3/8* [9.53] 25 [7.62] 25 [7.62] 17 [5.18] 8 [2.44] 0 N/A 1/2 [12.7] 25 [7.62] 39 [11.89] 37 [11.28] 36 [10.97] 34 [10.36] 32 _[9.75] NOTES: `Standard line size N/A = Application not recommended. • • • • •• • • • • • • • • • • • • • • • • • • • • • • •• • • • • • Suction Line Length/Size versus Capacity Multiplier (R-22) "•' • • • • Unit Size 11/zTon 2Ton 21/2Ton 3Ton 31/2Ton •••i••4Ton ••1 :0pn .. • •• • Suction Line Connection Size 3/4" [19 05] I.D. 7/8" [22.23] I.E • • • = Suction Line Run- s/8' [15.88 mm] O.D. Opt. �4� ]O.D. Opt. �/4" [19.05 mm] O.D. Opt. • �a4 P3 ]O.D.•Stdt*• •'/e' [22.23mm] a.a. Opt.. Feet [m] 3/4" [19.05 mm] 0.D. Std * [1905 m]5.88 /8" [22.23 mm] 0.D. Std.` [22 mm]5 . 1 �(8" [28.58 yip] Q.D. Std." z /a" [22.23 mm] O.D. Opt. 11/a" [28.58 mm] O.D.bpt. • • • Optional .99 .99 .98 .99 .99 .99 - .99 25' [7.62] Standard 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Optional - 1.00 1.00 - 1.00 - - Optional .97 .96 .96 .98 .97 .98 .97 50' [15.24] Standard .99 .99 .98 .99 .98 .99 .99 Optional - .99 .99 - 1.00 - - Optional .94 .92 .94 .95 .93 .95 .95 100' [30.48] Standard .96 .96 .96 .96 .96 .98 .98 Optional - .97 .97 - .98 - - Optional .90 .89 .92 .93 .92 .93 .93 150' [45.72] Standard .93 .93 .93 • .94 .94 .96 .96 Optional - .95 .95 - .96 - - NOTES: 'Standard line size Using suction line larger than shown in chart will result in poor oil return and is not recommended. [ ] Designates Metric Conversions • • � • • • • • 6 WeatherKing NOTES • ... • • • .... •• • •• • . • • .. .... . .... Id.• • . .... • .. • • • .. .. • . : . • • .... • • • • .... •... • .. ▪ • • • • . . • • • • • .. • • WeatherKing 7 .... • • •• • •••• ••. • • •• . • ••• .. • • • • • •• •• • • • • • • • • • • •• • • • • • • • •••• • • • • • ••• • • • .. • • • • • •• • • • •• • • • • .• • Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. \VIAIFII=I: "In keeping with its policy of continuous progress and product improvement, WeatherKing reserves the right to make changes without notice." PRINTED IN U.S.A. 1-14 QG FORM NO. P66-765 REV. 10 Supersedes Form No. P66-765 Rev. 9 ti Congratulations on your purchase of the TECHKO Sete Pool model S1870 safety alarm. The Safe Pool can be used to provide a high volume alarm alert when chadren have entered a pool or spa area. The S187D can be used outdoors on wood or metal gates, or indoors on doors and window leading directly to potentially dangerous areas. The Safe Pod is designed to sound a bud alert when children enter througyhh a Safe Pool protected door/gate. When properly Installed the Sate Pool will allow adults to pass through the protected doorlgate and immediately shut off the sounding alarm. When powered, the Safe Pool is ahvaye in protection mode. The alarm will activate the instant when the door/gate opens by more than 1f2 inch (When the magnetic sensors ere apart by more than 112 inch)., Once the alarm activates, tl will sound continuously until the BYPASS button is pressed. When passing through the dont/gate press the BYPASS button, then open the door/gate. pass through end dose the door/gate within 8-12 seconds and the alarm will not activate. 1a:F, z • Easy installation for gate, door or window protection • Water 1 weather resistant 9 Volt battery power (not Included) • High output 110-115 dB alarm siren • Low Battery / sgnal LED Indicator ' Optional additional BYPASS button for delayed entry from other side of door or fence • Optional additional magnetic sensor for screen door exit/entry Fop. • Alarm siren is VERY loud; NEVER place the unit doer to SM. Install the unit high enough to be out of reach of children 54' or higher is recommended. • • •. •• • • • • • • • • . • • • • • • ••• • • • •• •• • • • • •• • • • • ••• •• • • • • • • • • • • • . . •.• •• • • •• • . • • • • • • • • • • • • . •• • Keep this manual for future reterense. • • • • •• . . • • • •• • • • • • • • • • • • . •• • • . . . . • Tice Safe Pool can provide valuable4trisu; • pro�cofloonnnctlyt• fiechkocannot be held resporaible fa any ices. dame•or kqury that may occur. used However It carn oeagainst accidents or YtJtt WARNING: Read all installation and operation Instructions thoroughly before proceeding with Installation. Note: Not all parts included are needed for installation. Please read the different mounting instructions to see whet is needed for your specific application. INSTALLING THE BATTERY: 1. When testing, before installing the battery, use a rubber band to temporarily secure the two magnetic sensors together with the errows pointing toward each other to avoid setting off the alarm unintentionally. During the actual Installation of the alarm, it's best to install the battery after it's mounted to avoid the alamr going cif unintentionally. 2. Remove the battery cover of the unit and instatl a new 9 Volt battery. Replace cover. (See Fig. 2) 3. If you are sensitive to bud sound, phase wear ear protection against the loud a lam, siren before testing the alarm.. 4. Once the battery is connected. the unit is now ON and wonting. To test the alarm siren. make sure you have ear protection before testing. Alter ear protection is in place, separate the magnetic sensors apart by more than Y• inch. The alarm should sound immediately after the sensors ere separated. Press Vie BYPASS button end immediately segue the two magnet sensors together again to avoid the alarm sounding cif reententlonelly. -,,,,,•11* • •• • . • • • • • • • • • •.• •*OUNa1l8: 111ARNINi: The alarm should be positioned close to • .ihdoor enn enough to be out of the mesh of childre • shove* nb g application varies, Techko suggests testing the units installation location and effectiveness before permanently mounting the S187D. MOUNTING INDOORS Using the provided nrountlng template printed In this manual, mart the position of the screw holes on the desired mounting surface. LED LIGHT WARNINGS 1. When ire battery becomes tow in charge or the volume becomes weak, the LED light will Illuminate. The 9 volt battery must be replaced. 2. Upon battery Installation, the unit will beep once and the LED light will flash 10 times as it prepares to become armed. 3. When a bypass button is pushed, the LED light llumdnates to indicate admowtedgement to PASS through. 4. Alter the bypass button is pushed in and released, the LED light will flash 10 times to allow pass through and to prepare the unit to become armed again. • The Adsltbvnei delay button may be mounted on the other side of the entrance. When pressed, it will delay the alarm 8-12 seconds before alarm is triggered, allowing time t0 secure the door/gate. P. Sown tiro''aefr‘ 1 ti Fla. S * The Additional magnetic sensors allow the unit to be used on sliding door with screens. * Alarm will sound only when BOTH sets of magnetic sensors are apart therefor allowing the slider to be open while still providing protection at the screen door. MOUNTING INDOORS USING DOUBLE -SIDED TAPE Make sure that the mounting surfaces for the double -sided tapes are completely dean. Attach the double -sided tapes onto the rear of the unit, and then secure the unit onto the desired mounting surface. MOUNTING INDOORS USING SCREWS Using the provided mounting template printed in this manual, mark the position of the screw holes on the desired mounting surface, Orel the screws Into the mounting surface with approximately 118 Ind* dthread remaining. Slide the unit over the strews end segue the tarn by pushing it downward, es shown in Fig. 4. You may need to adjust the screws towards or away from the mounting surface to provide a more secure et. Rims Ow [11,1 no. 4 TEMPLATE MODEL S187D SCREW HOLE SCREW HOLE omr • • ••• • • •• •• • •• •• • ••• • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • ••• ••• • ••• • • • • •• • • • •• • •� ••• • • • ••• • • • • • �� • • • • • • •• • • o • •• ••• • ••• • • • • •• MOUNTING THE SENSORS • Make sure that the Brows of each sensor are,so4sd %Oda • • • each other. Using ether the double -sided tape or the saws • • • • provided, mount the sensors so that they are less than Yi inch away from each other. Sensors crust be mounted lush in help t end depth, so with some doors or windows, epeeist custom fitting may be necessary. Please make sure that the wired portion of the magnetic sensor is mounted on the non-moving portion of the mounting avface and the standalone sensor Is mounted on the door/gate. (See Fig. 5 /Fig. 6) YOUNiMG OUTDOORS ON WOODEN GATES Using the provided mounting template printed in this manual. mark the podgcn of the screw holes on the desired mounting surface. Orel the screws ono the mounting surface with epprwdrnately 1/6 inch of thread remaining. Slide the unit ore the screws and 5 secure the unit by pinning it downward es shown. in F g. 5. You may need to adjust the screw towards or away from the :mounting surface to provide a more secure tit. Made mire that the arrow of each sensor ere painted In The same duecbon. Note: Wooden gates do not risque, the sensor housings., INOUNT040 OUTDOORS ON METAL. OATES Using the provided zip ties. • Owen the Slum body to •ne metal gate frame. (See Fig. 6) Using r small Sat heed saawd Iver,gettly pry open the recessed senor specer of the sensor housing. ( tig.6) Make sure that the arrows d each sans{ are pointed in to same direction SS the eersor Fl• s haai.9 before placing the magnetic sensors inside the sensor housing. Note: Meal slabs my hearfN• M@h the magnetic sensor function. the spaces provided to ensure sensors operate property. Secure the sensors using the zip ties onto die gate frame. Make sure that the sensors' arrows ere pointed towards each other and that the sensors we less then "A inch wart n When the alarm volume becomes low, or the unit does not produce normal alarm sound, the red light will illuminate, you must replace the 9-volt battery. The Safe Pool's plastic parts resists ultraviolet rays from direct sunlight exposure. However. slight discoloration over lirne i5 normal, •• • .. •• WARNING! THE SAFE POOL ALARM IS EXTREMELY LOUD WHEN ACTIVATED. FOR YOUR SAFETY, NEVER PLACE THE UNIT CLOSE TO YOUR EARS. TO TEST THE ALARM, ALWAYS USE EAR PROTECTION AND DIRECT THE UNIT AWAY BEFORE TESTING/ACTIVATING THE ALARM, IT IS PROHIBITED BY LAW TO REMOVE THE INSTALLED ALARM AFTER IT HAS PASSED INSPECTION 1 Importltnt Warranty Information: A dated proof of purchase Is required for warranty service Customer Service : 1-888-8TECHK0(1-888-883-2456) Website: www.techkomaid,com Mfg. By lEalffe 9767 Research Drive, Irvine, CA 9261E-4626 MADE IN CHINA 9700127 COMPLIES WITH UL 2017 USA Patent: No. 5,473,310 No. 6,727,819 NOTICE THIS PROOUCT IS PROTECTED UNDER FEDERAL PATENT, TRADEMARK AND COPYRIGHT LAWS AND LAWS PREVENTIN9 UNFAIR COMPETRmoN. NO DUPUCATION OR SIMULATION OF THIS PRODUCT IS PERMNTTEO EXCEPT BY WRfTTEJi AUTHORlzAT)oN OF TECHKO, INC. .. TECHKO AND THE CONFIGURATION OF Tins PROOUCT ARE TRADEMARKS OF TECHKO iNC_ COPYRIGHT 1*94 TECHKO, NC, ALL R1GHT6 RESERVED MADE 1N CHINA rii3cififfic).3 Safe Pool"' Model SI87D Area Entry Alarm 2/17/2017 Nicheless LED Lights ( Jandy Pro Series 4 SAVE $100 ON A JANDY VS PUMP + iQPUMPO1 Learn More (http://www.jandy.com/en/igpump0l) United States (/en) / Product Archive (/en/product-archive) / Archived Lighting (/en/product-archive/lighting) / Nicheless LED Lights NICHELESS LED LIGHTS • • • .. .• . ....•. • ...... .... • • •••. •. • .. ••• •. • ••.•.. : . .•.... • . .... • •. •. . • ...... • • .. . • •..... .. •• • ...... . •. . • • • • .. .. . ..•. • ••• . .. . • .. . .. Quick and Easy Installation Jandy Pro Series Nicheless LED lights require no bonding or traditional niches, making the installation process quick and simple, resulting in a very low total cost of... • Full Description • Specifications & Technical Details • Models • Parts • Brochures & Manuals Find a Dealer (http://www.zodiac.com/en/united-states/find/dealer-locator) DESCRIPTION Quick and Easy Installation Jandy Pro Series Nicheless LED lights require no bonding or traditional niches, making the installation process quick and simple, resulting in a very low total cost of installation. For lighting with fewer hot spots, use multiple lower power lights instead of one high power light. Jandy Pro Series Nicheless Lights are the perfect retrofit for fiber optic replacement, as they mount directly to 1-1/2" return fittings. Control your lights anytime, anywhere with iAquaLinkTM, (https://www.iaqualink.com/en/#/overview) and all pool features even the light colors, can be selected and controlled from your smartphone or web -connected device. To learn more, or to download the app, visit iAquaLink.com. Jandy Pro Series Nicheless LED lights are controllable and compatible with AquaLink® automation systems. ..... .• ... • . O 00000 • • O 0000• • • ..•... • • Features • AquaLink & iAquaLink compatible • 100% Non -Metallic, No bonding required • Nine vibrant colors and five light shows available • Pure white light for the most efficient pool illumination (white lights) • Deep blue lights create vivid illumination for dramatic effect http://www.jandy.com/en/product-archive/lighting/nicheless-led 1/2 2/17/2017 Nicheless LED Lights 1 Jandy Pro Series • Covers and accessories also available • SPECIFICATIONS /TECHNICAL DETAILS MODELS PARTS BROCHURES & MANUALS Protect your warranty! Professional Installation REQUIRED Jandy • • • •• • • • • • • • • • • • • • • • • • • •• • • • • • • • • • • Build the perfect pool environment with Jandy Pro Series professional -grade swimming pool equipment. With a full line of pumps, filters, heaters, lights, valves, water sanitizers, and the automation solutions to control it all, Jandy has the complete equipment package for any swimming pool or spa. US. NEWSLETTER SIGN UP Sign Up Today Join our United States email list to participate in product development and research, and receive exclusive offers and latest news on our top products! First Name Last Name Email I agree to receive emails from Zodiac and its subsidiaries related to products and services. Subscribe Corporate (http://www.zodiac.com/en/united-states) Support (http://www.zodiac.com/en/united-states/contact) Find a Dealer (http://www.zodiac.com/en/united-states/find/dealer-locator) Contact (http://www.zodiac.com/en/united-states/contact) Legal (http://www.zodiac.com/en/legal) 2017 Zodiac Pool Solutions - All rights reserved. Zodiac is a registered trademark of Zodiac International, S.AS.U., used under license. All other trademarks referenced herein are the property of their respective owners. Pro Resources • • • • • • • • • • • •••. Login to your Zodiac Premium® account nowl1 g l eecess to prp• • • resources. •••••• • .••• Login Now (https://premium.zodiacpoolsystemsta• • •••••• • • •• •• •••••. • •• • • ••••• • • ••••• •••••• ••.••• • • • • • • • • • • • • • • • • • • • • • • • • • •••••• • • http://www.jandy.com/en/product-archive/lighting/nicheless-led 2/2 Phone: (305) 552-7504 D �j n n D D D▪ / Fax: (305) 229-8068 /r u �J A LrJ O -R-L�� E-mail: enpav@yahoo.es PROFESSIONAL LAND: SLR•Vt1 t :& MAPPER • t,• - • PROPERTY ADDRESS: 10501 NE 3rd Ave. Miami Shores, FL.•331`38" 14317 SW 45th Terrace Miami, FL. 33175 LEGAL DESCRIPTION: Lot 18 and the SoutP:%2 :)f:Lpt•i7,•E3bck.:2,.6f FIRST ADDITION TO PASADENA PARK, according to the plat thereof as racoided in Plaf Book & it Page 82, of the Public Florida.' Records of Miami Dade County, Florida. • •.. .•. •:• '•• 4'1C. 0 LwJ 0 0 0 m o cc 0 u Fd0 < 1/ZALP —£l _ Z Q rc1.13 0.. � CC Z .S. O 0 w Lu m • Q M fn Remainder of LOT- 17 BLOCK- 12 0 0 1� ED Rc_.,t IV4'.BS.WOII OCT It 2 ':1::3 Fd. 1/2' I.P. NOTE: Elevations are referred to Miami Dade County BM# D-159 Elev.= 10.32' OF N.G.V.D. of 1929 LOT- 2 LOCK- 12 0 0 •... • •• •.. .. • • • • • •. • . • • • . • • • .. 4' C.I.S. Wall 75.00' ONE STORY Res.# 10501 F.F.Elev.: 12.26' LOT- 1 BLOCK- 12 0 Fd. 1/7' I.P. of 0.50' Cy Pool EquiRMent a/ BASED ON THE FLOOD INSURANCE RATE MAP OF THE FEDERAL EMERGENCY AGENCY REVISED ON 9-11-09 THE HEREIN DESCRIBED PROPERTY IS SITUATED WITHIN: ZONE X BASE FLOOD ELEV. N/A COMMUNITY NUMBER: 120652 PANEL NUMBER 0302 SUFFIX L LEGAL NOTES THIS SURVEY DOES NOT REFLECT OR DETERMINE OWNERSHIP. EXAMINATION OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS. IF ANY, AFFECTING THE PROPERTY. THIS SURVEY IS SUBJECT TO DEDICATION, LIMITATIONS, RESTRICTIONS, RESERVATIONS OR EASEMENTS OF RECORDS. LEGAL DESCRIPTION PROVIDED BY CLIENT. THE LIABILITY OF THIS SURVEY IS LIMITED TO THE COST OF THE SURVEY. UNDERGROUND ENCROACHMENTS. IF ANY, ARE NOT SHOWN. THIS FIRM HAS NOT ATTEMPTED TO LOCATE FOOTING AND/OR FOUNDATIONS AND/OR UNDERGROUND IMPROVEMENTS OF ANY NATURE. IF SHOWN BEARINGS ARE REFERRED TO AN ASSUMED MERIDIAN. IF SHOWN ELEVATIONS ARE REFERRED TO N.G.V.D. OF 1929 THE CLOSURE IN THE BOUNDARY SURVEY IS ABOVE 1: 10000 DATE OF FIELD WORK: September 20, 2018 REVISED ON: I hereby certify that the attached Sketch of Survey of the herein described property is to the best of my knowledge and belief, a true and correct representation, of a field survey performed under my direction. And also meets the Minimum Technical Standards as set forth by the Florida Board of Professional Surveyors and Mappers in chapter 5J-17.050 thru 5J-1 F.A.C. pursuant to Section 472.027 F. S. ARTURO R. TOIRAC P.S.M. 3102 Not valid without the signature and the original embosed seal of a Florida Licensed Surveyor and Mapper. SKETCH OF SURVEY (Boundary Survey) SCALE 1" = 20' \O' X 14.95' Veronica Scatena LEGEND AND ABBREVIATIONS JOB No. 180940 A= ARC DISTANCE AC= AIR CONDITIONED UNIT B.C.= BLOCK CORNER C.B.= CATCH BASIN ICI= CALCULATED CL.= CLEAR C.L.F.= CHAIN LINK FENCE CONC.= CONCRETE D.M.E.= DRAINAGE MAINT. EASEMENT ENC.= ENCROACHMENT FD.= FOUND I.F.= IRON FENCE (M)= MEASURED M/L= MONUMENT LINE O.H.= OVERHEAD UTILITIES P.C.P.= PERMANENT CONTROL POINT P.O.B.= POINT OF BEGINNING P.O.C.= POINT OF COMMENCE R= RADIUS (R)= RECORD RES.= RESIDENCE R/W= RIGHT-OF-WAY TYP.= TYPICAL U.E.= UTILITY EASEMENT W.F.= WOOD FENCE W.M.= WATER METER 0= DIAMETER c= CENTER LINE 0' = ELEVATION ® = WATER METER ca.) = POWER POLE *O = LIGHT POLE = CATCH BASIN O= SANITARY SEWER w Ix1 = WATER VALVE ® = TV BOX