Loading...
PL-17-63BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC ❑PLUMBING ❑ MECHANICAL JOB ADDRESS: 386 NE 92 ST. Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 ❑ ROOFING • PUBLIC WORKS 4- R CE JAN 1 0 2017 BY: FBC 201“ Master Permit No. Sub Permit No. ❑ REVISION ❑ EXTENSION ❑ RENEWAL CHANGE OF ❑ CANCELLATION ❑ SHOP -CONTRACTOR DRAWINGS City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO X Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Address: City: State: Zip: Tenant/Lessee Name: Phone#: Email: RIGHT OF WAY Phone#: CONTRACTOR: Company Name: TECO PEOPLES GAS Address: 5101 NW 21 AVE. STE. 460 City: FT. LAUDERDALE Qualifier Name: JESUS VEGA State Certification or Registration #: E1608 DESIGNER: Architect/Engineer: Address: City: Value of Work for this Permit: $ 1000 Type of Work: ❑ Addition ❑ Alteration Phone#: 954-453-0806 Zip: 33309 Phone#: 954-453-0806 Certificate of Competency #: Phone#: State: Zip: Square/Linear Footage of Work: ❑ New ❑ Repair/Replace n Demolition Description of work: PERMIT TO INSTALL A NEW GAS SERVICE LINE Specify color of color thru tile: Submittal Fee $ Scanning Fee $ Technology Fee $ Permit Fee $ Radon Fee $ Structural Reviews $ CCF $ W O CO/CC $ DBPR $ 2 - Notary $ Training/Education Fee $ •' 2, a Double Fee $ Bond $ TOTAL FEE NOW DUE $ J i O (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature ;►Siii$,ture OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this- The foregoing instrument as acknowledged before me this day of , 20' , by 9 day of - , 20 / -% , by , who is personally known to 'YgS "s (%g c} , who is personally known to me or who has produced as me or who has produced as identification and who did take an oath. identificatid who did take an oath. NOTARY PUBLIC: NOTARY Sign: S Print: Print: Seal: Seal: ,,,,Y,,, PU HUBERT NUNEZ • ;=o`0.� ; Notary Public - State of Florida 1, 2017 . Commission # FF 043679 "";, ftl;'i' Bonded Tbrougn au n wt ;....ary Assn. *********************************************************************************************************** APPROVED BY ,10 n Plans Examiner Zoning Clerk (Revised02/24/2014) Structural Review LY SYMBOLS: ® Work Area ■ Channelizing Device (See Index No. 600) ft Work Zone Sign Flagger Automated Flagger Assistance Devices (AFAD), With Gate Lane Identification + Direction of Traffic GENERAL NOTES: 1. Special Conditions may be required in accordance with these notes and the following sheets. 2. If the Work Area encroaches on the Centerline, use the Layout for Temporary Lane Shift to Shoulder on Sheet 2 only if the Existing Paved Shoulder width is sufficient to provide for an 11' lane between the Work Area and the Edge of Existing Paved Shoulder. Reduce the posted speed when appropriate. 3. Temporary Raised Rumble Strips: a. Use when both of the following conditions are met concurrently: i. Existing Posted Speed is 50 mph or greater; li. Work duration is greater than 60 minutes. b. Use a consistent Strip color throughout the work zone. c. Place each Rumble Strip Set transversely across the lane at locations shown. d. Use Option 1 or Option 2 as shown on Sheet 2. Use only one option throughout work zone. 4. Additional one-way control may be provided by the following means: a. Flag -carrying vehicle; b. Official vehicle; c. Pilot vehicles; d. Traffic signals. When flaggers are the sole means of one-way control, the flaggers must be in sight of each other or in direct communication at all times. 5. When a side road intersects the highway within the TTC zone, place additional TTC devices in accordance with other applicable TCZ Indexes. 6. The two channelizing devices directly in front of the work area may be omitted provided vehicles in the work area have high -intensity rotating, flashing, oscillating, or strobe lights operating. Taper Length 50' to 100' Buffer Space / See Table 1 Tangent Device Spacing Taper Length) See Table 1 50' to 100 GENERAL LAYOUT 7. When Buffer Space cannot be attained due to geometric constraints, use the greatest attainable length, not less than 200 ft. B. Railroad Crossings: a. If an active railroad crossing is located closer to the Work Area than the queue length plus 300 feet, extend the Buffer Space as shown on Sheet 2. b. If the queuing of vehicles across an active railroad crossing cannot be avoided, provide a uniformed traffic control officer or flagger at the highway -rail grade crossing to prevent vehicles from stopping within the highway -rail grade crossing, even if automatic train warning devices are in place. 9. ROAD WORK AHEAD and the BE PREPARED TO STOP signs may be omitted if all of the following conditions are met a. Work operations are 60 minutes or less. b. Speed limit is 45 mph or less. c. There are no sight obstructions to vehicles approaching the work area for a distance equal to the Buffer Space shown in Table 1. d. Vehicles in the work area have high -intensity, rotating, flashing, oscillating, or strobe lights operating. e. Volume and complexity of the roadway has been considered. f. If a railroad crossing is present, vehicles will not queue across rail tracks, • • • • • • • • • • • g. AFADs ate not in use• 10. See Index 600♦ror geni-y. TT r• �ui.me0(s • , additioonl information. • • • • • • • • • • • •ri• •• • • • :,• 11. Automated Flagger Assistance Devices (AFADs) may be used in accordance with the Notes on Sheet 3. LAST REVISION 07/01/15 O 00 DESCRIPTION: FDOT • • • • • • • • • • • • • • • • • • • • • • • •• • ♦ •• —•• • ••• • • • • • • • • • • • • * May be omitted if ROAD WORK AHEAD sign is installed upstream within the project limits. TABLE 1 Posted Speed DEVICE SPACING Distance Between Signs Buffer Space Maximum Spacing of Cones or Tubular Markers Maximum Spacing of Type I or Type II Barricades/Panels/Drums 0n a Taper Ona Tangent Ona Taper Ona Tangent A BCD 25 20' 50' 20' 50' 200' 200' 200' 100' 155' 30 20 50' 20' 50' 200' 200' 200' 100' 200' 35 20' 50' 20' 50' 200' 200' 200' 100' 250' 40 20' 50' 20' 50' 200' 200' 200' 100' 305' 45 20' 50' 20' 50' 350' 350' 350' 175' 360' 50 20' 50' 20' 100' 500' 500' 500' 250' 425' 55 20' 50' 20' 100' 2640' 1500' 1000' 500' 495' 60 20 50' 20' 100' 2640' 1500' 1000' 500' 570' 65 20' 50' 20' 100' 2640' 1500' 1000' 500' 645' 70 20' 50' 20' 100' 2640' 1500' 1000' 500' 730' CONDITIONS WHERE ANY VEHICLE, EQUIPMENT, WORKERS OR THEIR ACTIVITIES ENCROACH THE AREA BETWEEN THE CENTERLINE AND A LINE 2' OUTSIDE THE EDGE OF TRAVEL WAY. 2016 DESIGN STANDARDS • • • • • • • • • • • 0 ••• • • • • • • • • •• •• • • • •• •• • • • • • • • • • • • • • • • • • • • TWO-LANE, TWO-WAY, WORK WIITHIIN THE TRAVEL WAY INDEX NO. 603 SHEET NO. 1 of 3 SOD RESTORATION DETAIL SCALE: NOT TO SCALE ALL EXISTING UTILITIES SHOWN ON THESE PLANS ARE TO BE CONSIDERED APPROXIMATE & SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO THE START OF WORK OPERATIONS. LEGEND CENTER LINE M MONUMENT LINE R/W RIGHT OF WAY P/L PROPERTY LINE E.O.P. EDGE OF PAVEMENT T.T. TAPPING TEE E.F.V. EXCESS FLOW VALVE SVC. SERVICE LINE PE. PLASTIC STM. SEW. STORM SEWER SURFACE REPLACOAENT EASE (NEW MATERIAL) LOCATION MAP (N.T.S) FULL LANE SURFACE REPLACEMENT 12" VARIES ,Y RESTORATION OF ROAD CUT FOR UTILITY CROSSING GENERAL NOTES SAW CUT ASPHALT TYPICAL) W S SCALE: 1"=20. 1. REPLACED BASE MATERIAL OVER DITCH SHALL BE TWICE THE THICKNESS OF THE BASE, MIN. 8" AND MAX. 18" 2. BASE MATERIAL SHALL BE PLACED IN 6" MAX. (LOOSE MEASUREMENT) LAYER AND EACH LAYER THOROUGHLY ROLLED OR TAMPED TO 98% OF MAX. DENSITY PER AASHTO T-180 3. ASPHALT CONCRETE PAVEMENT JOINTS SHALL BE MECHANICALLY SAWED 4. SURFACE MATERIAL SHALL BE CONSISTENT WITH SURROUNDING SURFACE MATERIAL (1.5" MIN. THICKNESS) 5. BASE MATERIAL SHALL HAVE A MIN. LBR. OF 100 AND A MIN. CARBONATE CONTENT OF 70% (60% FOR LOCAL STREETS) 6. CONTRACTOR SHALL SOFT DIG TO VERIFY LOCATION OF EXISTING UTILITIES PROP. RISER WIT} 3/4" PLASTIC GAS SVC. TO BE DIRECTIONAL BORED 8 � - ORD. S f W ---______ -}---1_ i0 4 GAS SVC. TO BE \ DIRECTIONAL BORED 36" MIN. — I 0 I — I .2 C.I. MAIN iGAS PROFILE CROSSING AN ALLEY SCALE: (V) 1:5' (H) NTS. 0.45' a. 9' 0.25' Cl. 1 -1 Vt 0 20' ASPHALT PAVEMENT Fnd. 1R' I.P. (No I.D.) 0 N 0 K K CONC SLAB 5.00'/ - v+ So. '' a U) 0 D U) 0 D 0 `Fnd r}2"a'P. 11 D (No 10) ASNHA T.PAVEMEI Q0 24' PKWY • .•.w.••. • •..• •• • • • • • • .•, lidiSTFZE • ] • • • • • • • • .• C • • • • • • D•• • ••L • • r •� • • • • • .. • • • • ♦ • • • • • • • • • • • •• • • 105.41' (M) 48.50' 22.00' One Story Residence #386 TILED STEP 21.60' 18.90' 0 ¢� LLL16 LL LL 111lllllI111 }-; A _, A, I I I MOM 11 21 L LL L L_ LL y ..LLLLLLLLLLLLLLLLLLL(- LLLLL .IL_ LLL LLL _LLLLLLlTi1L.r' • LLL LLL _LLLLLL * LLL _LL _LLLLLLL� LLL LLL _LLLLLLLLLLLL LLL -LLLLLLLLLLLLLLLLLLL 4' 8.00' • • • • • • •• ?' 19.65' N 19.00' 11.50' o l A/C CONC. SLAB PROP. 3/4" PE. GAS SVC. TO BE DIRECTIONAL BORED TIE IN SVC. TO GAS MAIN WITH T.T/E.F.V. XIST. 2' C.I. GAS MAIN R/w 0 • 35.00 Fnd. 1/2" I.P. (No 1.D.) N 03 a) 35.00' cn > ri m: m 0 a a rn 0 a a 12-27-2016 M 0 00 M co 0 a NO. OF BHSSrs• 1 SHEET NO.: 1 Drawing File: G:\Documents\RESIDENTIAL\2016\NE 92 ST. 386, MIAMI SHORES, FL\386 NE 92 ST.MIAMI SHORES, FL.dwg 12/27/2016