ELC-18-2140Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Pe Permit NO. ELC-8-1 8-2140 Permit Type: Electrical - Commercial Work Classification: Addition/Alteration Permit Status: APPROVED Issue Date: 9/4/2018 Expiration: `03103/2019 Parcel Number Applicant 9823 NE 4 Avenue Miami Shores, FL 1132060170330 Block: Lot: MIAMI SHORES COMM CHURCH Owner Information Address Phone CeII MIAMI SHORES COMM CHURCH INC 9823 NE 4 AVE MIAMI FL 33138-2402 Contractor(s) MOODY ELECTRIC INC Phone (305)758-2000 Cell Phone Valuation: $ 27,245.00 Total Sq Feet: 0 Type of Work: INSTALL NEW ELECTRICAL SYSTEM FOR T Additional Info: INSTALL NEW ELECTRICAL SYSTEM FOR T Classification: Commercial Scanning: 4 Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee Scanning Fee Technology Fee Total: Amount $16.80 $12.26 $8.18 $5.60 $817.35 $3.00 $22.40 $885.59 Pay Date Pay Type Invoice # ELC-8-18-68517 09/04/2018 Credit Card 08/13/2018 Credit Card Amt Paid Amt Due $ 835.59 $ 50.00 $ 50.00 $ 0.00 Available Inspections: Inspection Type: Final Meter Box Alteration Relocation Fire Alarm Service Change Review Mechanical Review Mechanical W. W. Review Electrical Underground In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: construction a certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating on . Fute, I authgJize the dove -named contractor to do the work stated. /14 horized Signature: Owne4 Applicant / Contractor / Agent Bu rding Department Copy September 04, 2018 Date September 04, 2018 1 Tenant/Lessee Name: beim) 147309 Phone#: Ve 7 �t� 9131 Email: CONTRACTOR: Company Name: /l/%0(/�.ygl6C•T,�IC !,L jG. Address: .1eizA h4 • zz//?'Ye /11/g4tZe City: Mar Qualifier Name: oa'n/ ft/' �Po State Certification or Registration #: _/ Certificate of Competency #: EC mua//`frf DESIGNER: Architect/Engineer: 4i/STiQV .5O c 4. J-e Phone#: 30,f &, ems, 4 /S7 Address: City: State: Zip: Value of Work for this Permit: $ eo7 6,244J: d•o Square/Linear Footage of Work: Type of Work: ❑ Addition E Alteration LJ New ❑ Repair/Replace ❑ Demolition Description of Work: —TA/6 r.4, - .0 E4J gi6crIe, 4-1, "sue / .///4e7>e cJ /f/N/ s ,--,. A /c u.u, rs iN r s�tea-,us . F,e usr‘ 'd' /,.r6r'A=e.c. ,-A-°�• Area, LGb S/ ,,;� -e,:.• ,,. ; , ? ,, ,- 'R'r`° [e jaAsz� �l�c to c,�3 rid . i ) Specify color`of color. thrultile.. P . , ,;:+ _ . : x State: GD.eith.04- OWNER: Name (Fee Simple Titleholder): Plea./M/ 'kz,VW Address: 9 mil, . / /'� " ^ City: /Ct/!YL/j/Z1t.� State: !� c �g3� Zip: Phone#: 3403' 74 •Zaao i T _:,= 3 13. :t: e Isla YS✓ Submittal Fee $ �L• r , . .Permit ke$, _ Scanning Fee $ Radon Fee $ 9 ( Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ELECTRIC ❑ ROOFING ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS RECEIVED AUG 13 2018 •)- FBC 20I9- Master Permit No. LI 8 - ai g O Sub Permit No. W.19 - 21 1 ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 32 3 A/• 4 ' ,4V Uu j City: Miami Shores Folio/Parcel#: Is the Building Historically Designated: Yes Occupancy Type: C 6Q•Load: County: Miami Dade Construction Type: C.8$ Flood Zone: Zip: 33,/38 NO BFE: FFE: Zip: 33502o Phone#: 74 • 236 • q6 CCF $ CO/CC $. . ,•, , ,• DBPR $> I Z• Notary Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ Ti .31 - �� (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address 4/I4 City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated: I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. I ��• "WARNING.:30;,,OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULLIN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR;LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faithLthat a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencernenemust be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued., In the absence of such posted notice, the • inspection will not be approved and a reinspection fee will be charged. Signatur'r„� ", AICiteiN) OWNER or AGENT Signeturr A`14 `.',,; t.'N - - CONTRACTOR 1; The foregoing'instrument was acknowledged before me this The'foregoing instrument was acknowledged befo a me this 1P-' •day of-- A-11 US , 20 I $ , by —71 b day "of'-''. -1 \1.95'4' •.w:+. 20 IS5 , by who is personally known to JO1r h J . Mn , who is personally known to as br whorhas produced- ''' who has produced' identification and who did take an oath. NOTARY PUBLIC: Sign: nn p p�j r Print: f'l � OlL�� t`la ._" 'g i nt: `' C19r '1\1UYi07_ -�. ,,# ti ati• .�, ;Seal: 'N identification and who did take an oath. t.R NOTARY PUBLIC:-'° •'a' • as Seal otery PUbIIC State of Florida ,( Rebeca Munoz A, My Commission FF 916344 APPROVED B ign: Plans Examiner s* IN, Notary Public State of Florida Rebeca Munoz ' r I My Commission FF 916344 * 4* ssrSi * * > lMa i `*19 * * ************ Zoning Structural Review Clerk (Revised02/24/2014) 8/13/2018 Property Search Application - Miami -Dade County Summary Report Property Information Folio: 11-3206-017-0330 Property Address: 9823 NE 4 AVE Miami Shores, FL 33138-2402 Owner MIAMI SHORES COMM CHURCH INC Mailing Address 9823 NE 4 AVE MIAMI, FL 33138-2402 PA Primary Zone 1200 SGL FAMILY - 2501-2800 SQ Primary Land Use 7144 RELIGIOUS - EXEMPT : RELIGIOUS Beds / Baths / Half 0/0/0 Floors 2 Living Units D Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 22,482 Sq.Ft Lot Size 37,121.2 Sq.Ft Year Built 1930 Assessment Information Year 2018 2017 2016 Land Value $1,115,070 $1,115,070 $927,142 Building Value $974,864 $974,864 $928,440 XF Value $28,613 $29,007 $29,401 Market Value $2,118,547 $2,118,941 $1,884,983 Assessed Value $2,118,547 $2,030,308 $1,845,735 Benefits Information Benefit Type 2018 2017 2016 Non -Homestead Cap Assessment Reduction $88,633 $39,248 Religious Exemption $2,118,547 $2,030,308 $1,845,735 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 4 PB 15-14 LOTS 1 TO 6 INC & ALL OF ALLEY BLK 88 AS VACATED PER CITY ORDINANCE NO 237 BLK 88 LOT SIZE IRREGULAR Generated On : 8/13/2018 Taxable Value Information 2018 2017 2016 County Exemption Value $2,118,547 $2,030,308 $1,845,735 Taxable Value $0 $0 $0 School Board Exemption Value $2,118,547 $2,118,941 $1,884,983 Taxable Value $0 $0 $0 City Exemption Value $2,118,547 $2,030,308 $1,845,735 Taxable Value so so $0 Regional Exemption Value $2,118,547 $2,030,308 $1,845,735 Taxable Value $0 $0 $0 Sales Information Previous Sale Price OR Book -Page Qualification Description The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: 8/13/2018 Detail by Entity Name Department of State / Division of Corporr, / Search Rec orris / Search by Entity Name / Detail by Entity Name Florida Not For Profit Corporation MIAMI SHORES COMMUNITY CHURCH, INC. Filing Information Document Number N49539 FEI/EIN Number 59-0657328 Date Filed 06/24/1992 State FL Status ACTIVE Principal Address 9823 NE 4TH AVE. MIAMI SHORES, FL 33138 Changed: 03/18/2009 Mailing Address 9823 NE 4TH AVE. MIAMI SHORES, FL 33138 Changed: 03/18/2009 Registered Agent Name & Address SASTRE, MICHAEL A 2 SOUTH BISCAYNE BLVD. SUITE 3050 MIAMI, FL 33131 Name Changed: 05/20/2009 Address Changed: 05/20/2009 Officer/Director Detail Name & Address Title President PATTAVINA, DIANE 758 NE 90 Street #515 MIAMI, FL 33138 Title VP http://search.sunbiz.org/Inquiry/CorporationSearch/SearchResultDetail?inquirytype=EntityName&directionType=Initial&searchNameOrder=M IAM ISHORESC.. 1/3 8/13/2018 Detail by Entity Name LANGFORD, DRACE 720 NE 69 STREET #8 MIAMI, FL 33138 Title Treasurer Snyder, Clint 5401 Collins Ave #137 Miami Beach, FL 33140 Title Secretary Merrill, Brenda 5929 NE 6th Ave MIAMI, FL 33137 Title MINISTER AND CAO WATSON, MARGARET, REV 386 NE 99 STREET MIAMI SHORES, FL 33138 Annual Reports Report Year Filed Date 2016 03/29/2016 2017 03/02/2017 2018 03/27/2018 Document Images 03127.2018 — ANNUAL REPORT 03/02/2017 -- ANNUAL REPORT 03/29/2016 -- ANNUAL REPORT 04/08/2015 -- ANNUAL REPORT 06/27/2014 — AMENDED ANNUAL REPORTi 03/03/2014 — ANNUAL REPORT View image in PDF format View image in PDF format View image in PDF format View image in PDF format 03/19/2013 — ANNUAL REPORT 03/20/2012 -- ANNUAL REPORT 05/11/2011 --ANNUAL REPORT 03/02/2010 — ANNUAL REPORT 05/20/2009 — Reg. Agent Change 03/18/2009 — ANNUAL REPORT 03/14/2008 — ANNUAL REPORT 04/02/2007 —ANNUAL REPORT 07/05/2006 — ANNUAL REPORT 04/14/2005 — ANNUAL REPORT 02127/2004 — ANNUAL REPORT 05/05/2003 — ANNUAL REPORT View image in PDF format View image in PDF format View image in PDF format View image in PDF fommat View image in PDF format View image in PDF format View image in PDF format ........................................... _......................................... View image in PDF format View image in PDF format View image in PDF format View image in PDF format View image in PDF fomiat View image in PDF format View image in PDF format http://search.sunbiz.org/Inquiry/CorporationSearch/SearchResultDetail?i nqui rytype=EntityName&di rectionType= Initial&searchNameOrder=M IAM ISH OR ESC.. 2/3 MOODY ELECTRIC, INC. PROPOSAL www.moodyelectric.com July 6, 2018 3812A N. 29th Avenue • Hollywood, FL 33020-1008 Tel: (305) 758-2000 Fax: (305) 754-1333 Proposal Submitted to: Miami Shores Community Church 9823 NE 4th Avenue Miami Shores, FL 33138 Job Name: Air Conditioning Mini -Splits Tel / Email: 407-416-9134 / dean@miamishoresucc.org Attn: Dean Watson Location: School Building Job Descriation: 1.) Furnish and install a new electrical system for thirteen (13) mini -split A/C systems. — Ten (10) condensing unit. — Thirteen (13) fan coil units. 2.) Install thirteen (13) 20 amp single pole switches for the fan coils. 3.) Furnish and install thirteen (13) thermostat control. circuits. 4.) Furnish and install thirteen (13) single phase fusible disconnect switches for over current protection for the A/C units. 5.) Provide all necessary conduit and wiring for the A/C units as shown on sheets EI-E3 per Gustavo Solana dated 623/18. 6.) Furnish and install a new 100 amp electrical feeder from panel "MCB" to Panel "B". Notes: Panel "A" has cloth insulation conductors and does not meet codes. Cost to repair $4,000.00 in addition to this proposal. All patching and painting is by others. ,' A permit will be provided at actual cost, plus,a S300.00 filing and inspection fee, in addition to this proposal. - Any additional services required by the Authorities Having Jurisdiction will be considered a change to the scope and will be quoted as a change. Moody Electric is not a financing company. Signing this proposal constitutes a legal contract , Please pay close attention to the progress payments. WE PROPOSE hereby to furnish material and labor - complete in accordance with these specifications for the sum of Twenty Seven Thousand Two Hundred. Forty Five Dollars S27,245.00 Payable as follows: Progress Billings Every Two (2) Weeks Payments Net 7 Days In the event customer fails to pay this proposal when due, Moody Electric, Inc. shall be entitled to recover all costs incurred including aftomey's fees for services rendered in connection with collection of payment of the debt as evidence by this proposal or enforcement of Moody Electric inc.'s rights provided under law. NOTE: This proposal may be withdrawn by us if not accepted within 30 days. INCREASES IN MATERIAL. COST. In the event that, during construction of the improvement described herein, contractor's costs for materials used or to be used herein are increased by more than 10% over the contractor's costs for the same at the time this agreement was signed, for any cause(s) beyond the control of contractor, then, and in such event(s), contractor shall have the right to pass the entire n eur thf material costs increase(s) along to • er by adding the total amount(s) thereof to the Contract Price. Moody Electric, Inc. Authorized Si . tore QUOTED BY: John J. Moody - ST.L1C fEC00D1199 CBE / SHE Broward County Certified SBE - SFVNMD Certified Acceptance of Proposal -The prices, specifications and conditions are sa - ctory and are her accepted. You are authorized to do the work specified. Payment will be made as outlined above. Signatutef! t � m f 1 e!a �n01 e� Date —15-.n Signature Print f\C 1)))-Or Print Date 7 /J '�Je A-7 Page 1 of 1 Air System Sizing Summary for FCU-1A Project Name: 18-068 Miami Shores Community Church 07/05/2018 Prepared by: RPJ, Inc. 04:OOPM Air System Information Air System Name FCU-1A Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 195.0 ft2 Location Miami IAP, Florida Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load. 0.8 Tons Load occurs at Jul 1800 Total coil load 9.0 MBH OA DB / WB 88.6 / 76.4 °F Sensible coil load 7.8 MBH Entering DB / WB 76.2 / 63.5 °F Coil CFM at Jul 1800 360 CFM Leaving DB / WB 56.1 / 54.9 °F Max block CFM 360 CFM Coil ADP 53.9 °F Sum of peak zone CFM 360 CFM Bypass Factor 0.100 Sensible heat ratio 0.865 Resulting RH 47 % CFM/Ton 478.0 Design supply temp. 55.0 °F ft2/Ton 259.2 Zone T-stat Check 1 of 1 OK BTU/(hrft2) - 46.3 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 5.5 MBH Load occurs at Des Htg Coil CFM at Des Htg 360 CFM BTU/(hr.ft2) 28.2 Max coil CFM 360 CFM Ent. DB / Lvg DB 68.4 / 82.6 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 360 CFM Fan motor BHP . . 0.05 BHP Standard CFM 359 CFM Fan motor kW 0.04 kW Actual max CFM/ft2 1.84 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 22 CFM CFM/person 10.85 CFM/person CFM/ft2 .. 0.11 CFM/ft2 •• • • • • • • • • •• • • • • • • • • •• • • • •• • • • •• • • •• • • . • • • • • • • • •• • • • • • • • • •• •• • • • •• • • • • ••• •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • PEN,q GE Ns . s ntn ,163 `�F`,�� •S!0 N N�...`•,.,-,.,. 4 Hourly Analysis Prograrir.11;" • • • •• •• "• ••• • • Page 1 of 3 Air System Sizing Summary for FCU-7 Project dame: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:04PM Air System Information Air System Name FCU-7 Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 739.8 ft2 Location Miami IAP, Florida Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space Toads Central Cooling Coil Sizing Data Total coil load 3.3 Tons Load occurs at Jul 1600 Total coil load 39.3 MBH OA DB / WB 90.7 / 76.9 °F Sensible coil load 25.4 MBH Entering DB / WB 79.8 / 67.9 °F Coil CFM at Jul 1600 979 CFM Leaving DB / WB 55.7 / 54.7 °F Max block CFM 979 CFM Coil ADP 53.0 °F Sum of peak zone CFM 979 CFM Bypass Factor 0.100 Sensible heat ratio 0.647 Resulting RH 51 % CFM/Ton 298.9 Design supply temp. 55.0 °F ft2/Ton 225.9 Zone T-stat Check 1 of 1 OK BTU/(hrft2) 53.1 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 16.7 MBH Load occurs at Des Htg Coil CFM at Des Htg 979 CFM BTU/(hrft2) 22.6 Max coil CFM 979 CFM Ent. DB / Lvg DB 63.0 / 78.9 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 979 CFM Fan motor BHP 0.13 BHP Standard CFM 978 CFM Fan motor kW 0.11 kW Actual max CFM/ft2 1.32 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 289 CFM CFM/person 14.44 CFM/person CFM/ft2 0.39 CFM/ft2 l 9'oaaates�,� 4,,,,.. \\ ;' •:\ G E�N S .:0( , • • •• •'t\ No 163 . •• ••• • • • • • •• • 300 • • • ; 13 .•. . CC y F fi•. ,,, • ••• • .•• • •,�/ • • • • • • • • • e`pn,a er. .- • • • • • • • • • iiiiyi • • • • • • • • • • • •• • •• • • • • • • ••• • • • ••• • • • • ••• • • • • • • • • • • • ••• • • Hourly Analysis Program `;.11 , • • • • • • • • • • ••• • • • ••• • Page 1 of 3 Zone Sizing Summary for FCU-7 Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:04PM Air System Information Air System Name FCU-7 Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 739.8 ft2 Location Miami IAP, Florida Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFMI Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBHJ Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 1 930 930 1.26 0.0 - 0.0 - 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 20.1 Jul 1700 9.2 739.8 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 02 Classroom 13/14/15 1 13.3 Jul 1700 617 6.2 498.3 1.24 02 Classroom 13/14/15-1 1 6.8 Jul 1700 313 3.0 241.5 1.30 .• ••• . • • • • •. • • • • • • • • •• ••• .. . • • • • • • • • • • • • • • ••. • • • • . . • • • • • • • • • • • • • . • • • •. • • • • .•. • • • ••• • • • • ••• • • • • • • • • • • • • • ••• • • •_ Hourly Analysis Program':.11.• • • • • ••• ••• •• • • • • • •••• • • • ••• • • • Page 2 ,of 3 Air System Design Load Summary for FCU-7 Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:04PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1600 COOLING OA DB / WB 90.7 °F / 76.9 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 130 ft2 2477 - 130 ft2 - - Wall Transmission 413 ft2 2681 - 413 ftz 3430 - Roof Transmission 740 ft2 1015 - 740 ft2 985 - Window Transmission 130 ft2 1946 - 130 ftz 3370 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 68 ft2 569 - 68 ft2 985 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 814 W 2777 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 740 W 2524 - 0 0 - People 20 4900 4100 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 5% 944 205 5% 438 0 » Total Zone Loads - 19832 4305 - 9208 0 Zone Conditioning - 19278 4305 - 9117 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 979 CFM 0 - 979 CFM 0 - Ventilation Load 289 CFM 4805 9552 289 CFM 7525 0 Supply Fan Load 979 CFM 363 - 979 CFM -363 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 992 - 5% 460 - » Total System Loads - 25438 13857 - 16740 0 Central Cooling Coil - 25438 13857 - 0 0 Central Heating Coil - 0 - - 16740 - » Total Conditioning - 25438 13857 - 16740 0 Key: Positive values are clg loads Negative values are htg toads Positive values are htg toads Negative values are clg loads • • 060 • • • • • • • • • • • • • • • • •• ••• •• • • • •• • ••• • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • f • • • • • • • • • ••• • • • 0410 • • • • 000 • • • • • • • • • • Hourly Analysis Program.;.11. • • •• • • • • • •• •• • • • •• •• ••• • • • 000 • • Page 3'of 3 Air System Sizing Summary for FCU-8 Project Name: 18-068 Miami Shores Community Church 07/05/2018 Prepared by: RPJ, Inc. 04:05PM Air System Information Air System Name FCU-8 Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 739.8 ft2 Location Miami IAP, Florida Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 3.3 Tons Load occurs at Jul 1600 Total coil load 40.1 MBH OA DB / WB 90.7 / 76.9 °F Sensible coil load 26.1 MBH Entering DB / WB 79.7 / 67.7 °F Coil CFM at Jul 1600 1001 CFM Leaving DB / WB 55.5 / 54.5 °F Max block CFM 1001 CFM Coil ADP 52.8 °F Sum of peak zone CFM 1001 CFM Bypass Factor 0.100 Sensible heat ratio 0.651 Resulting RH 51 % CFM/Ton 299.6 Design supply temp. 55.0 °F ft2/Ton 221.3 Zone T-stat Check 1 of 1 OK BTU/(hrft2) 54.2 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load .. 17.2 MBH Load occurs at Des Htg Coil CFM at Des Htg 1001 CFM BTU/(hrft2) 23.2 Max coil CFM 1001 CFM Ent. DB / Lvg DB 63.1 / 79.0 °F Water flow @ 20.0 'F drop N/A Supply Fan Sizing Data Actual max CFM 1001 CFM Fan motor BHP 0.14 BHP Standard CFM 1001 CFM Fan motor kW 0.11 kW Actual max CFM/ft2 1.35 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 289 CFM CFM/person 14.44 CFM/person CFM/ft2 0.39 CFM/ft2 •• • • • • • • • • •• • • • • • • • • • •• • • • •• • • •• • • II. • • • • • • • • • • • • • • • • • • • ,i • • • • • • • • • • • • • • • •• • •• • • • • • • • • • • • • • • • • • • V • • • • • • • • • • • • • • • • • • • • • • Hourly Analysis Program ':.11 • • • • •• • • • • • • • • Page 1 of 3 ••• • • • • • • • • Zone Sizing Summary for FCU-8 Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:05PM' Air System Information Air System Name FCU-8 Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 739.8 ft2 Location Miami IAP, Florida Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (_CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 1 951 951 1.29 0.0 - 0.0 - 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 20.5 Jul 1700 9.8 739.8 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 02 Classroom 16/17/18 1 6.8 Jul 1700 313 3.0 241.5 1.30 02 Classroom 16/17/18-1 1 13.8 Jul 1700 638 6.8 498.3 1.28 • • 000 • • • • • • • • • • • • • • • • •• ••• •• • • • •• • 000 • 000 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • 000 • • • • • • • • • • Hourly Analysis Program 5.11: ; • : : : : : • : Page 2 of 3 • •• •• • • • •• •• ••• • • • ••• • • Air System Design Load Summary for FCU-8 Project -Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:05PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1600 COOLING OA DB / WB 90.7 °F / 76.9 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTUIhr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 163 ft2 2697 - 163 ft2 - - Wall Transmission 380 ft2 2530 - 380 ft2 3156 - Roof Transmission 740 ft2 1015 - 740 ft2 985 - Window Transmission 163 ft2 2440 - 163 ft2 4225 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 68 ft2 569 - 68 ft2 985 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 814 W 2777 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 740 W 2524 - 0 0 - People 20 4900 4100 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 5% 973 205 5% 468 0 » Total Zone Loads - 20423 4305 - 9819 0 Zone Conditioning - 19911 4305 - 9566 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 1001 CFM 0 - 1001 CFM 0 - Ventilation Load 289 CFM 4815 9683 289 CFM 7497 0 Supply Fan Load 1001 CFM 371 - 1001 CFM -371 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 1021 - 5% 491 - » Total System Loads - 26119 13988 - 17182 0 Central Cooling Coil - 26119 13988 - 0 0 Central Heating Coil - 0 - - 17182 - » Total Conditioning - 26119 13988 - 17182 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads •• •.• • • • • • •• • • • • • • • • • •• •.• •• • • • •• • .•• • • • • • • • • • • • • • • • • • • • • • • • • • • . • • . . • . • . •• • •• • • • • • • • • • • • • • • • . • • • • • • • • • • • • • . . • • • • •.. • • • • •- • • . • • Hourly Analysis Program 5.11•. • ; •. • • • • •• • • • • • • • • • • • • • Page 3 of 3 Air System Sizing Summary for FCU-9 Project Name: 18-068 Miami Shores Community Church 07/05/2018 Prepared by: RPJ, Inc. 04:05PM Air System Information Air System Name FCU-9 Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 762.4 ft2 Location Miami IAP, Florida Sizing Calculation Information Calculation Months .. Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 3.5 Tons Load occurs at Aug 1600 Total coil load 42.4 MBH OA DB / WB 90.7 / 76.9 °F Sensible coil load 29.5 MBH Entering DB / WB 79.0 / 66.7 °F Coil CFM at Aug 1600 1180 CFM Leaving DB / WB 55.9 / 54.8 °F Max block CFM 1180 CFM Coil ADP 53.3 °F Sum of peak zone CFM 1180 CFM Bypass Factor 0.100 Sensible heat ratio 0.697 Resulting RH 49 % CFM/Ton 334.3 Design supply temp. 55.0 °F ft2/Ton 216.0 Zone T-stat Check 1 of 1 OK BTU/(hrft2) 55.6 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise NIA Central Heating Coil Sizing Data Max coil load 19.5 MBH Load occurs at Des Htg Coil CFM at Des Htg 1180 CFM BTU/(hrft2) 25.5 Max coil CFM 1180 CFM Ent. DB / Lvg DB 64.1 / 79.3 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 1180 CFM Fan motor BHP 0.16 BHP Standard CFM 1180 CFM Fan motor kW 0.13 kW Actual max CFM/ft2 1.55 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 291 CFM CFM/person 14.57 CFM/person CFM/ft2 0.38 CFM/ft2 •• ••• • • • • • •• • • • • • . • • • •• ••* .• • • • .• • ••• • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • ••• • • • • ••• • • • • • • • • • • 0,0 • • Hourly Analysis Program 5.11' • • • • • • • • • • • • • • • • • • Page 1 of 3 Zone Sizing Summary for FCU-9 Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:05PM Air System Information Air System Name FCU-9 Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 762.4 ft2 Location Miami IAP, Florida Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) 0 Zone 1 1121 1121 1.47 0.0 - 0.0 - Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 23.8 Sep 1500 12.1 762.4 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 02 Classroom 19 1 10.3 Oct 1600 478 4.9 381.2 1.25 02 Classroom 19-1 1 13.9 Aug 1500 643 7.2 381.2 1.69 •• ••• • • • • • •• • • • • • • • • • Y• ••• •• • • • •• • ••• • ••• • • • • • • • • • • • • • • • • • • • • • • • • • It • • • • • • • • • • • • • • • • • • • • • • • • • • t • • • • • • • • • • • • • • • Hourly Analysis Program 5.11: • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • Page 2 of 3 Air System Design Load Summary for FCU-9 Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:05PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1600 COOLING OA DB / WB 90.7 °F / 76.9 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 198 ft2 3829 - 198 ft2 - - Wall Transmission 604 ft2 4559 - 604 ft2 5019 - Roof Transmission 762 ft2 1001 - 762 ft2 1016 - Window Transmission 198 ft2 2964 - 198 ft2 5132 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - DoorLoads 23 ft2 190 - 23 ft2 328 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 839 W 2861 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 762 W 2601 - 0 0 - People 20 4600 2400 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 5% 1130 120 5% 575 0 » Total Zone Loads - 23735 2520 - 12070 0 Zone Conditioning - 23056 2520 - 11767 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 1180 CFM 0 - 1180 CFM 0 - Ventilation Load 291 CFM 4856 10302 291 CFM 7545 0 Supply Fan Load 1180 CFM 437 - 1180 CFM -437 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 1187 - 5% 603 - » Total System Loads - 29536 12822 - 19478 0 Central Cooling Coil - 29536 12824 - 0 0 Central Heating Coil - 0 - - 19478 - » Total Conditioning - 29536 12824 - 19478 0 Key: Positive values are clg loads Negative values are htg Toads Positive values are htg loads Negative values are clg loads •. •.• • . • • • • .. • • • • • •• ••• • • • •• • • • •• • • • • • ••. • • • • • • • . • • • • • • • • • • • • • • • • • . • . • • • •• • •.• •• • • • • • ••. • • • . • Hourly Analysis Program 5:11 • • . • ;' • • • • • • • . • • • • • • • • • • • • • •• •• • . • .• •• • • • • • . .•. • • Page 3 ;of 3 Air System Sizing Summary for FCU-10A Project Name: 18-068 Miami Shores Community Church 07/05/2018 Prepared by: RPJ, Inc. 03:57PM Air System Information Air System Name FCU-10A Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 340.3 ft2 Location Miami IAP, Florida Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 1.9 Tons Load occurs at Aug 1500 Total coil load 23.1 MBH OA DB / WB 91.0 / 77.0 °F Sensible cot load 15.2 MBH Entering DB / WB 79.7 / 67.7 °F Coil CFM at Aug 1500 595 CFM Leaving DB / WB 56.0 / 55.0 °F Max block CFM 595 CFM Coil ADP 53.4 °F Sum of peak zone CFM 595 CFM Bypass Factor 0.100 Sensible heat ratio 0.660 Resulting RH 51 % CFM/Ton 309.8 Design supply temp. 55.0 °F ft2/Ton 177.0 Zone T-stat Check 0 of 1 OK BTU/(hrft2) 67.8 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 10.3 MBH Load occurs at Des Htg Coil CFM at Des Htg 595 CFM BTU/(hrft2) 30.3 Max coil CFM 595 CFM Ent. DB / Lvg DB 63.7 / 79.7 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 595 CFM Fan motor BHP 0.08 BHP Standard CFM 595 CFM Fan motor kW 0.06 kW Actual max CFM/ft2 1.75 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM ... 161 CFM CFM/person 13.40 CFM/person CFM/ft2 0.47 CFM/ft2 • •• ••• • • • • • •• • C 1 ` eeC�'') R • • • •.r� �'••'y • .e •• ••• •• • • • irej2g ` a,1 • ••• • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • •. • • • • • • • • •• • • • • ••• • Hourly Analysis Program 5:11 • • • • - • • • • • • • • • • • • • •• •• • • • •• .• ••• • • • •.• • • Page 1 of 3 Zone Sizing Summary for FCU-10A Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 03:57PM Air System Information Air System Name FCU-10A Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 340.3 ft2 Location Miami IAP, Florida Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 1 566 566 1.66 0.0 - 0.0 - 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 12.2 Aug 1500 6.0 340.3 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 02 Classroom 20 1 12.2 Aug 1500 566 6.0 340.3 1.66 • •. •.• • • • • • •• • . • • • • .• • • • •. • • • •• • • • • • • • • • • • • • • • • • . • • • • • • • • • • • . • • • • • • • • • • • •• • •• • • • • • • • • • . • • •• • ••• • Hourly Analysis Program 11- • • • . • • • • • ••• • • • • • • • . • • • • •• •• • • • •• • • • • • • • • • • • Page 2 of 3 Air System Design Load Summary for FCU-10A Projeci Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 03:57PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1500 COOLING OA DB 1 WB 91.0 °F / 77.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads , 66 ft2 1909 - 66 ft2 - - Wall Transmission 385 ft2 2753 - 385 ft2 3195 - Roof Transmission 340 ft2 406 - 340 ft2 453 - Window Transmission 66 ft2 995 - 66 ft2 1711 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 23 ft2 191 - 23 ft2 328 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 374 W 1277 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 340 W 1161 - 0 0 - People 12 2940 2460 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor " 5% / 5% 582 123 5% 284 0 » Total Zone Loads - 12214 2583 - 5971 0 Zone Conditioning - 11701 2583 - 6029 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load ' 0% 0 - 0 0 - Plenum Lighting Load L 0% 0 - 0 0 - Return Fan Load 595 CFM 0 - 595 CFM 0 - Ventilation Load I 161 CFM 2690 5263 161 CFM 4201 0 Supply Fan Load 9 595 CFM 221 - 595 CFM -221 - Space Fan Coil Fans ! - 0 - - 0 - Duct Heat Gain / Loss 5% 611 - 5% 299 - » Total System Loads - 15222 7846 - 10308 0 Central Cooling Coil 15222 7847 0 0 Central Heating Coil i -• 0 - - 10308 - » Total Conditioning j - 15222 7847 - 10308 0 Key: 1 Positive values are clg Toads Negative values are htg loads Positive values are htg loads Negative values are clg loads •• ...' • • • • • •• • • • • • •., • . • • ••• • • •' OOOOOO • •• .•.t •• • • • •. • ••. • • • • • • • • • • • • • • • • •• .. • • l••• • • • • . • • • • . • • • • • • • . • • • • • Hourly Analysis Program C(1 • �;• • • Page 3 of 3 • • • • • ••• • • • • • • • • • • • • • ••• •••• .• • • • .. •• • • ••• • • Air System Sizing Summary for FCU-1OB Project Name: 18-068 Miami Shores Community Church 07/05/2018 Prepared by: RPJ, Inc. 04:OOPM Air System Information Air System Name FCU-10B Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 578.2 ft2 Location Miami IAP, Florida Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 2.5 Tons Load occurs at Jul 1700 Total coil load 30.4 MBH OA DB / WB 89.9 / 76.7 °F Sensible coil load . 21.2 MBH Entering DB / WB 78.5 / 66.4 °F Coil CFM at Jul 1700 862 CFM Leaving DB / WB 55.6 / 54.6 °F Max block CFM 862 CFM Coil ADP 53.1 °F Sum of peak zone CFM 862 CFM Bypass Factor 0.100 Sensible heat ratio 0.698 Resulting RH 49 % CFM/Ton 340.2 Design supply temp. 55.0 °F ft2/Ton . 228.3 Zone T-stat Check 1 of 1 OK BTU/(hrft2) 52.6 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 13.8 MBH Load occurs at Des Htg Coil CFM at Des Htg .. . 862 CFM BTU/(hrft2) 23.8 Max coil CFM 862 CFM Ent. DB / Lvg DB 65.0 / 79.8 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 862 CFM Fan motor BHP 0.12 BHP Standard CFM 861 CFM Fan motor kW 0.09 kW Actual max CFM/ft2 1.49 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 189 CFM CFM/person 15.78 CFM/person CFM/ft2 0.33 CFM/ft2 .. •.• . . • . . •. • • • • • • • .. ... •• • • • ••• . • •• • • • • . • • • . • • • . .. • • • •.. . • • • • • • • • . •• • • • • . . . • . . • •• . • . • • • . . • . . .•• • • • . • . • • • Hourly Analysis Program 5:11 • • • • • • • • • • • •: ••• • • • ••• • • Page 1 of 3 Zone Sizing Summary for FCU-10B Project Name: 18-068 Miami Shores Community Church 07/05/2018 Prepared by: RPJ, Inc. 04:OOPM Air System Information Air System Name FCU-10B Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 578.2 ft2 Location Miami IAP, Florida Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 1 819 819 1.42 0.0 - 0.0 - 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 17.7 Aug 1700 8.5 578.2 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 02 Classroom 21/22 1 17.7 Aug 1700 819 8.5 578.2 1.42 •• ••• • • • • • • •• •• • • . • • •• ••• •• • • • •• • ••• • ••• • • • • • • • • • • • • • • • • • • •• • •• • • ••. • • • • • • • • • • • • • • • • • • • • Hourly Analysis Program51'I • • • • • • • • • • • • • • • • • • • ••• • • •• •• • • • •• •• • • • •• •• ••• • • • ••• • • Page 2 of 3 Air System Design Load Summary for FCU-10B Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:OOPM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1700 COOLING OA DB / WB 89.9 °F / 76.7 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 98 ft2 2753 - 98 ft2 - - Wall Transmission 493 ft2 4222 - 493 ft2 4092 - Roof Transmission 578 ft2 861 - 578 ft2 770 - Window Transmission 98 ft2 1422 - 98 ft2 2540 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 46 ft2 368 - 46 ft2 657 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 636 W 2170 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 578 W 1973 - 0 0 - People 12 2940 2460 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 5% 835 123 5% 403 0 » Total Zone Loads - 17543 2583 - 8462 0 Zone Conditioning - 17047 2583 - 8704 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Pienum Lighting Load 0% 0 - 0 0 - Return Fan Load 862 CFM 0 - 862 CFM 0 - Ventilation Load 189 CFM 2986 6585 189 CFM 4969 0 Supply Fan Load 862 CFM 319 - 862 CFM -319 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 877 - 5% 423 - » Total System Loads - 21229 9168 - 13777 0 Central Cooling Coil - 21229 9168 - 0 0 Central Heating Coil - 0 - - 13777 - » Total Conditioning - 21229 9168 - 13777 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg Toads Negative values are clg loads •• ••• • • • • • • • • . • • • • •• • •• ••• •• • • • •• • ••• • .•. • 111 • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • •• • • ••• • • • • • • Hourly Analysis 1 Program•9•.'1 • • . • • • • • • • . • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •. ••• • Page 3 of 3 Zone Sizing Summary for FCU-1A Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:OOPM Air System Information Air System Name FCU-1A Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 195.0 ft2 Location Miami IAP, Florida Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space Toads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 1 342 342 1.75 0.0 - 0.0 - 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 7.4 Jul 1800 5.0 195.0 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 01 School Office A 1 7.4 Jul 1800 342 5.0 195.0 1.75 •r ••• • • • • • • • • • • • ••• • • ••• •• • • • •• • ••• • ••• • • • • • • • • • • • • • • • • • • •• • •• • • ••• • • • • • • It • • • • • • • • • • • • ••• • • • • ••• • • • • • • a — Hourly Analysis Program 5 11 •• • • • •• • •• • • •• •• • • • •• • ••• • • • ••• • Page 2 'of 3 Air System Design Load Summary for FCU-1A Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:OOPM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1800 COOLING OA DB / WB 88.6 °F / 76.4 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTUIhr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 49 ft' 679 - 49 ft' - - Wall Transmission 331 ft' 2964 - 331 ft' 2751 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 49 ft' 671 - 49 ft' 1270 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads 23 ft2 173 - 23 ft' 328 - Floor Transmission 195 ft' 0 - 195 ft' 441 - Partitions ow 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 300 W 1024 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 300 W 1024 - 0 0 - People 2 490 410 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 5% 351 21 5% 240 0 » Total Zone Loads - 7376 431 - 5030 0 Zone Conditioning - 7003 431 - 4818 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 360 CFM 0 - 360 CFM 0 - Ventilation Load 22 CFM 308 785 22 CFM 559 0 Supply Fan Load 360 CFM 133 - 360 CFM -133 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 369 - 5% 252 - » Total System Loads - 7813 1216 - 5495 0 Central Cooling Coil - 7813 1215 - 0 0 Central Heating Coil - 0 - - 5495 - » Total Conditioning - 7813 1215 - 5495 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg Toads Negative values are clg loads • • • • • • • • • •• •• • • • • • • • • • • • • • • •• • • •• ••• •• • • • •• • ••• • ••• • • • • • • ••• • • • • •• •• • • • • • • • • • • • •• • •• • • • • • • ••• • • • 0-0-0 Hourly Analysis Program I11 • 0.0 • • • • • • • • • • • • • • • • •:• •• • • • •• •• •• • • ••• • • Page 3 of 3 Air System Sizing Summary for FCU-1 B Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:01 PM Air System Information Air System Name FCU•1B Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 189.6 ft2 Location Miami IAP, Florida Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space Toads Central Cooling Coil Sizing Data Total coil load 1.0 Tons Load occurs at Jul 1500 Total coil load 12.4 MBH OA DB / WB 91.0 / 77.0 °F Sensible coil load 7.9 MBH Entering DB / WB 79.9 / 68.2 °F Coil CFM at Jul 1500 304 CFM Leaving DB / WB 55.8 / 54.9 °F Max block CFM 304 CFM Coil ADP .. 53.1 °F Sum of peak zone CFM 304 CFM Bypass Factor 0.100 Sensible heat ratio 0.637 Resulting RH 52 % CFM/Ton 293.7 Design supply temp. 55.0 °F ft2/Ton 183.3 Zone T-stat Check 1 of 1 OK BTU/(hrft2) 65.4 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 5.7 MBH Load occurs at Des Htg Coil CFM at Des Htg 304 CFM BTU/(hrft2) 30.3 Max coil CFM 304 CFM Ent. DB / Lvg DB 62.6 / 80.1 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 304 CFM Fan motor BHP 0.04 BHP Standard CFM 304 CFM Fan motor kW 0.03 kW Actual max CFM/ft2 1.60 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 93 CFM CFM/person 13.25 CFM/person CFM/ft2 0.49 CFM/ft2 o 7 .• ... •• ti3O: • • • 71 • • • • 7. m°-11 ••' ••• •• • • • •• °P U,% 1v., ^ f`a • ••• •• L. • •• • • • • • • • • • • • • • • • • Ydet;4 • • • • • • • • • • • •• • •• • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • 000 • • • • • • • Hourly Analysis Program 5.11 • • • • • • 000 • • Page 1 of 3 Zone Sizing Summary for FCU-1 B Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:01 PM Air System Information Air System Name FCU-1B Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 189.6 ft2 Location Miami IAP, Florida Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 1 289 289 1.52 0.0 - 0.0 - ' 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 6.2 Oct 1500 3.4 189.6 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 01 School Office B 1 6.2 Oct 1500 289 3.4 189.6 1.52 •. •.• • • • • • •. • •• • • • • • • •. ... •. • . • .• • •.. • ••• • • • • . • • • • . • • • • • . • • • • • • • . • • • • • • •• • •• • • . • • • ••• . • • Hourly Analysis Program 5.11 ••• • • • • ••• • • • ••• • • • • • • • • • ••• • • • • • • • • • • • • •• • • • •• •• • • ••• • • Page 2 of 3 Air System Design Load Summary for FCU-1 B Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:01 PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 91.0 °F / 77.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 49 ft2 725 - 49 ft2 - - Wall Transmission 162 ft2 968 - 162 ft2 1347 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 49 ft2 739 - 49 ft2 1270 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 23 ft2 191 - 23 ft2 328 - Floor Transmission 190 ft2 0 - 190 ft2 319 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 209 W 712 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 190 W 647 - 0 0 - People 7 1715 1435 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 5% 285 72 5% 163 0 » Total Zone Loads - 5981 1507 - 3428 0 Zone Conditioning - 5895 1507 - 3294 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 304 CFM 0 - 304 CFM 0 - Ventilation Load 93 CFM 1599 2997 93 CFM 2388 0 Supply Fan Load 304 CFM 113 - 304 CFM -113 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 299 - 5% 171 - » Total System Loads - 7905 4504 - 5741 0 Central Cooling Coil - 7905 4504 - 0 0 Central Heating Coil - 0 - - 5741 - » Total Conditioning - 7905 4504 - 5741 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg Toads •• • • • • . • • • •• • • • • • • • • • .• • • • •• • . • •• • • • • • .•. • • • . • • • • . • • • . • • • • • • • • • • • • . • • • • • •• • .• • • • • • • •.• • • • • • • • . • .•• • Hourly Analysis Program 5.11 • • • • • • • • • • • • • • • • • • • • • • •• •• • • • •• • • . • • • • • • Page 3 of 3 Air System Sizing Summary for FCU-2 Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:01 PM Air System Information Air System Name FCU-2 Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 511.8 ft2 Location Miami IAP, Florida Sizing Calculation Information Calculation Months ... Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 2.2 Tons Load occurs at Aug 1700 Total coil load 26.2 MBH OA DB / WB 89.9 / 76.7 °F Sensible coil load 17.4 MBH Entering DB / WB 79.1 / 67.2 °F Coil CFM at Aug 1700 686 CFM Leaving DB / WB 55.6 / 54.6 °F Max block CFM 686 CFM Coil ADP 53.0 °F Sum of peak zone CFM 686 CFM Bypass Factor 0.100 Sensible heat ratio 0.666 Resulting RH 50 % CFM/Ton 315.0 Design supply temp. 55.0 °F ft2/Ton 234.8 Zone T-stat Check 1 of 1 OK BTU/(hr•ft2) 51.1 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 12.4 MBH Load occurs at Des Htg Coil CFM at Des Htg 686 CFM BTU/(hrft2) 24.2 Max coil CFM .. 686 CFM Ent. DB / Lvg DB 63.7 / 80.4 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 686 CFM Fan motor BHP 0.09 BHP Standard CFM 686 CFM Fan motor kW 0.07 kW Actual max CFM/ft2 1.34 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 181 CFM CFM/person 15.12 CFM/person CFM/ft2 0.35 CFM/ft2 • • 000 • • • • • • • : c• - .ii • •• ••• •• • • • •• °y g1i@'rldr do.%• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Hourly Analysis Program 5.11 • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • 000 • • • 000 • • Page 1 [of 3 Zone Sizing Summary for FCU-2 Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:01 PM Air System Information Air System Name FCU-2 Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 511.8 ft2 Location Miami IAP, Florida Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F ' Mixing Box Fan Airflow (CFM) Zone 1 652 652 1.27 0.0 - 0.0 - 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 14.1 Jul 1700 7.6 511.8 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 01 Classroom 1/2 1 14.1 Jul 1700 652 7.6 511.8 1.27 •• • • • • • . • . .. • • • • • . • • • .. ..• •• . . • .• • ••. • ••. • • • • . • • • . • . • • • . • • • . • • . • • • • • • • • . •. • •. • • • • • • ••. • • • ••. • • • • • • • . • • . • • • • •• • • • .•• • . • • • . • • • . • • • Hourly Analysis Program 5.11 • •• •. • • • •• •• .•• • • • • • • • • Page 2 of 3 Air System Design Load Summary for FCU-2 Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:01 PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1700 COOLING OA DB / WB 89.9 °F / 76.7 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 114 ft2 2070 - 114 ft2 - - Wall Transmission 349 ft2 2578 - 349 ft2 2899 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 114 ft2 1654 - 114 ft2 2955 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 46 ft2 368 - 46 ft2 657 - Floor Transmission 512 ft2 0 - 512 ft2 755 - Partitions 0 ft2 0 - • 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 563 W 1921 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 512 W 1746 - 0 0 - People 12 2940 2460 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 5% 664 123 5% 363 0 » Total Zone Loads - 13940 2583 - 7629 0 Zone Conditioning - 13593 2583 - 7554 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 686 CFM 0 - 686 CFM 0 - Ventilation Load 181 CFM 2867 6160 181 CFM 4714 0 Supply Fan Load 686 CFM 254 - 686 CFM -254 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 697 - 5% 381 - » Total System Loads - 17411 8743 - 12395 0 Central Cooling Coil - 17411 8743 - 0 0 Central Heating Coil - 0 - - 12395 - » Total Conditioning - 17411 8743 - 12395 0 Key: Positive values are clg Toads Negative values are htg Toads Positive values are htg Toads Negative values are clg loads .. •.• • • . • • •• • • • • • •• ..• .• • .. • •• • ••• . .•. • • • . • . • • . . • • • • . • . . • • • • • • . • . . • • • • • • • • • • • • • • • • • • • • MMA Hourly Analysis Program 5.11 • . . • • . • • • • • 000 • • • • • • • • • • • • • • • • . • • • • • • • • 000 . . • 000 • • Page 3 of 3 Air System Sizing Summary for FCU-3A Project Name: 18-068 Miami Shores Community Church 07/05/2018 Prepared by: RPJ, Inc. 04:02PM Air System Information Air System Name FCU•3A Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 481.3 ft2 Location Miami IAP, Florida Sizing Calculation Information Calculation Months Jan to Dec . Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 2.0 Tons Load occurs at Jul 1600 Total coil load 23.9 MBH OA DB / WB 90.7 / 76.9 °F Sensible coil load 15.5 MBH Entering DB / WB 79.8 / 67.9 °F Coil CFM at Jul 1600 603 CFM Leaving DB / WB 55.9 / 55.0 °F Max block CFM 603 CFM Coil ADP 53.3 °F Sum of peak zone CFM 603 CFM Bypass Factor 0.100 Sensible heat ratio 0.648 Resulting RH 51 % CFM/Ton 302.2 Design supply temp. 55.0 °F ft2/Ton 241.3 Zone T-stat Check 1 of 1 OK BTU/(hrft2) 49.7 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 11.4 MBH Load occurs at Des Htg Coil CFM at Des Htg 603 CFM BTU/(hr•ft2) 23.7 Max coil CFM 603 CFM Ent. DB / Lvg DB 63.1 / 80.6 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 603 CFM Fan motor BHP 0.08 BHP Standard CFM 602 CFM Fan motor kW 0.07 kW Actual max CFM/ft2 1.25 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 178 CFM CFM/person 14.81 CFM/person CFM/ft2 0.37 CFM/ft2 ,`,,O's.� e9 P E Nq:'ro I' 163 1 No }. ••• ••• • • • • • •• ..-„°°. • • •• nCo ,\y,•• ••• •• • • •• -,',•L'5 NI ai' y • ••• • ••• • • • • • • • • • • • • • . • • • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • Hourly Analysis Program 5.11 • • • • • • • • • • • • • • • • ••• • • • • • • • •• •• • • ••• • • • • • • • • •• • Page 1 of 3 Zone Sizing Summary for FCU-3A Project Name: 18-068 Miami Shores Community Church 07/05/2018 Prepared by: RPJ, Inc. 04:02PM Air System Information Air System Name FCU-3A Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 481.3 ft2 Location Miami IAP, Florida Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 1 573 573 1.19 0.0 - 0.0 - 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 12.4 Oct 1500 6.5 481.3 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 01 Classroom 3/4 1 12.4 Oct 1500 573 6.5 481.3 1.19 •. ••• • • • • • •• • • • • • • • • • •• ••• •• • • • •• • ••• • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • •• • • • • •• ••• • • • ••• • • • • I • • • • • • • • • • • • • • • ••• • • • • • • • • Hourly Analysis Program 5.11 ••• • • • ••• • • Page 2'of 3 Air System Design Load Summary for FCU-3A Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:02PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1600 COOLING OA DB / WB 90.7 °F / 76.9 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 98 ft2 1480 - 98 ft2 - - Wall Transmission 276 ft2 1752 - 276 ftZ 2296 - Roof Transmission 0 ftZ 0 - 0 ft2 0 - Window Transmission 98 ft2 1467 - 98 ft2 2540 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 46 ft2 379 - 46 ft2 657 - Floor Transmission 481 ft2 0 - 481 ft2 655 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 529 W 1806 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 481 W 1642 - 0 0 - People 12 2940 2460 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 5% 573 123 5% 307 0 » Total Zone Loads - 12041 2583 - 6455 0 Zone Conditioning - 11734 2583 - 6633 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 603 CFM 0 - 603 CFM 0 - Ventilation Load 178 CFM 2957 5835 178 CFM 4655 0 Supply Fan Load 603 CFM 223 - 603 CFM -223 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 602 - 5% 323 - » Total System Loads - 15517 8418 - 11387 0 Central Cooling Coil - 15517 8418 - 0 0 Central Heating Coil - 0 - - 11387 - » Total Conditioning - 15517 8418 - 11387 0 Key: Positive values are clg loads Negative values are htg Toads Positive values are htg loads Negative values are clg loads •• • 000 • • • • • • • • • • • • • • • •• ••• •• • • • •• • ••• • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • •• • • • • • • ••• IS • • Hourly Analysis Program 5.11 • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• 000 • • • 000 • • Page 3of3 Air System Sizing Summary for FCU-3B Project Name: 18-068 Miami Shores Community Church 07/05/2018 Prepared by: RPJ, Inc. 04:02PM Air System Information Air System Name FCU-3B Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 511.8 ft2 Location Miami IAP, Florida Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 2.2 Tons Load occurs at Jul 1500 Total coil load 25.9 MBH OA DB / WB 91.0 / 77.0 °F Sensible coil load 17.2 MBH Entering DB / WB 79.5 / 67.4 °F Coil CFM at Jul 1500 669 CFM Leaving DB / WB 55.6 / 54.6 °F Max block CFM 669 CFM Coil ADP 53.0 °F Sum of peak zone CFM 669 CFM Bypass Factor 0.100 Sensible heat ratio 0.664 Resulting RH 50 % CFM/Ton 309.4 Design supply temp. 55.0 °F ft2/Ton 236.7 Zone T-stat Check 1 of 1 OK BTU/(hrft2) 50.7 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 12.2 MBH Load occurs at Des Htg Coil CFM at Des Htg 669 CFM BTU/(hrft2) 23.8 Max coil CFM 669 CFM Ent. DB / Lvg DB 63.5 / 80.4 °F Water flow @ 20.0 °F drop . N/A Supply Fan Sizing Data Actual max CFM 669 CFM Fan motor BHP 0.09 BHP Standard CFM 669 CFM Fan motor kW 0.07 kW Actual max CFM/ft2 1.31 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 181 CFM CFM/person 15.12 CFM/person CFM/ft2 0.35 CFM/ft2 •• ••• • • • • • •• • • • • • • • • • •• ••• •• • • • •• • ••• • ••• • • • • • • • • • • • • • • . • • • • • • • • • • • • • • • • •• • •• • • • • • • ••• • • • Hourly Analysis Program 5.11 • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• .• ••• • • • ••• • • Page 1 of 3 Zone Sizing Summary for FCU-3B Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:02PM Air System Information Air System Name FCU-3B Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 511.8 ft2 Location Miami IAP, Florida Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM)_ Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm © 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm © 20.0 °F Mixing Box Fan Airflow (CFM) Zone 1 636 636 1.24 0.0 - 0.0 - 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 13.7 Oct 1500 7.6 511.8 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 01 Classroom 5/6 1 13.7 Oct 1500 636 7.6 511.8 1.24 • .• ••. • • • • . •• • • • • • • • • •• • • • •• • • • •• • • • • • • • • • • . • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • •• • • • • • • • • • • • • • • • • • • • ••. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Hourly Analysis Program 5.11 • • • • • • • • • • • Page 2 'of 3 Air System Design Load Summary for FCU-3B Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:02PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 91.0 °F / 77.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 114 ft2 1953 - 114 ft2 - - Wall Transmission 348 ft2 2256 - 348 ft2 2894 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 114 ft2 1718 - 114 ft2 2955 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 46 ft2 382 - 46 ft2 657 - Floor Transmission 512 ft2 0 - 512 ft2 697 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 563 VV 1921 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 512 W 1746 - 0 0 - People 12 2940 2460 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 5% 646 123 5% 360 0 » Total Zone Loads - 13563 2583 - 7562 0 Zone Conditioning. - 13218 2583 - 7359 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 669 CFM 0 - 669 CFM 0 - Ventilation Load 181 CFM 3088 6133 181 CFM 4708 0 Supply Fan Load 669 CFM 248 - 669 CFM -248 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 678 - 5% 378 - » Total System Loads - 17232 8716 - 12197 0 Central Cooling Coil - 17232 8716 - 0 0 Central Heating Coil - 0 - - 12197 - » Total Conditioning - 17232 8716 - 12197 0 Key: Positive values are clg loads Negative values are htg Toads Positive values are htg loads Negative values are clg loads •• •.. • • . . . .. • •. • • • • • • •. .•• •• • • • •• • ••. • .•. • • . • • • • • • • • • • • • • • • • • • • . • • . • • • •. • •• • • • • • • • • • • • • Hourly Analysis Program 5.11 • • • • • • • • . . . • • • ••. • • • • • . • • • • • • •• • • • •• •• • • • • • Page 3 'of 3 Air System Sizing Summary for FCU-4 Project Name: 18-068 Miami Shores Community Church 07/05/2018 Prepared by: RPJ, Inc. 04:03PM Air System Information Air System Name FCU-4 Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 782.0 ft2 Location Miami IAP, Florida Sizing Calculation Information Calculation Months ... Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 3.1 Tons Load occurs at Aug 1600 Total coil load 36.8 MBH OA DB / WB 90.7 / 76.9 °F Sensible coil load 26.7 MBH Entering DB / WB 78.2 / 65.9 °F Coil CFM at Aug 1600 1099 CFM Leaving DB / WB 55.8 / 54.7 °F Max block CFM 1099 CFM Coil ADP 53.3 °F Sum of peak zone CFM 1099 CFM Bypass Factor 0.100 Sensible heat ratio 0.725 Resulting RH 49 CFM/Ton 358.6 Design supply temp. 55.0 °F ft2/Ton 255.1 Zone T-stat Check 1 of 1 OK BTU/(hr•ft2) 47.0 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 19.5 MBH Load occurs at Des Htg Coil CFM at Des Htg 1099 CFM BTU/(hrft2) 25.0 Max coil CFM 1099 CFM Ent. DB / Lvg DB 65.5 / 81.9 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 1099 CFM Fan motor BHP 0.15 BHP Standard CFM 1099 CFM Fan motor kW 0.12 kW Actual max CFM/ft2 1.41 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 214 CFM CFM/person 17.82 CFM/person CFM/ft2 0.27 CFM/ft2 Qi,p®tRN9! •• ••• • • • • w I •3 • `• Q* ' 1b .�a • O • • •• ••• •• • • ;� •; • ••• • ••• •. <it • • • • • • 1, ia, • • • • • • • :• k..••,c • • • • • • • • • '� • /i (.\ I •• •••• • ••• • • • •:•�h • a. ••• • • • • ••• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • Hourly Analysis Program 5.11 • •• •• • • • •• •• ••• • • • ••• • • Page 1 of 3 Zone Sizing Summary for FCU-4 Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:03PM Air System Information Air System Name FCU-4 Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 782.0 ft2 Location Miami IAP, Florida Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) Zone 1 1044 1044 1.34 0.0 - 0.0 - 0 Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 22.5 Oct 1500 13.6 782.0 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ftZ) Space CFM/ft2 Zone 1 01 Classroom 7 1 22.5 Oct 1500 1044 13.6 782.0 1.34 •• ••• • • • • • •• • • • • • • • • • • • 000 • • • • • • • • 000 , • 000 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 000 • • • Hourly Analysis Program 5.11 000 • • • • 000 • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • 000 • • Page 2 of 3 Air System Design Load Summary for FCU-4 Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:03PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1600 COOLING OA DB / WB 90.7 °F / 76.9 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 198 ft2 3829 - 198 ft2 - - Wall Transmission 748 ft2 5636 - 748 ft2 6213 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 198 ft2 2964 - 198 ft2 5132 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 23 ft2 190 - 23 ft2 328 - Floor Transmission 782 ft2 0 - 782 ft2 1322 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 860 W 2935 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 782 W 2668 - 0 0 - People 12 2940 2460 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 5% 1058 123 5% 650 0 » Total Zone Loads - 22219 2583 - • 13645 0 Zone Conditioning - 21576 2583 - 13655 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 1099 CFM 0 - 1099 CFM 0 - Ventilation Load 214 CFM 3561 7552 214 CFM 5588 0 Supply Fan Load 1099 CFM 407 - 1099 CFM -407 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 1111 - 5% 682 - » Total System Loads - 26655 10135 - 19518 0 Central Cooling Coil - 26655 10136 - 0 0 Central Heating Coil - 0 - - 19518 - » Total Conditioning - 26655 10136 - 19518 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads • • 000 • • • • • • • • • • • • • • • •• • ••• •• • • • •• • • • • • 000 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • Hourly Analysis Program 5.11 • • • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• 000 • • • 000 • • Page 3 of 3 Air System Sizing Summary for FCU-5 Project Name: 18-068 Miami Shores Community Church 07/05/2018 Prepared by: RPJ, Inc. 04:03PM Air System Information Air System Name FCU-5 Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 578.2 ft2 Location .. Miami IAP, Florida Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 2.5 Tons Load occurs at Aug 1700 Total coil load 30.2 MBH OA DB / WB 89.9176.7 °F Sensible coil load 21.1 MBH Entering DB / WB 78.6 / 66.5 °F Coil CFM at Aug 1700 864 CFM Leaving DB / WB 56.0 / 54.9 °F Max block CFM 864 CFM Coil ADP 53.5 °F Sum of peak zone CFM 864 CFM Bypass Factor 0.100 Sensible heat ratio 0.699 Resulting RH 49 % CFM/Ton 343.7 Design supply temp. 55.0 °F ft2/Ton 230.1 Zone T-stat Check 1 of 1 OK BTU/(hrft2) 52.1 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 14.6 MBH Load occurs at Des Htg Coil CFM at Des Htg 864 CFM BTU/(hrft2) 25.2 Max coil CFM 864 CFM Ent. DB / Lvg DB 64.8 / 80.4 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 864 CFM Fan motor BHP 0.12 BHP Standard CFM 863 CFM Fan motor kW 0.09 kW Actual max CFM/ft2 1.49 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 189 CFM CFM/person 15.78 CFM/person CFM/ft2 0.33 CFM/ft2 • • • • :, e • • • .. ••"i • •• ••• •• • • • ;Ike. , n d......., �N u Z or-jr t rn •• ••• • • • • •�..ttb°`\ .-n • ••• • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• 0 •• • • • • • • ••• • • • •4e •r Hourly Analysis Program 5.11 ... . . . . ••. • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • Page 1 of 3 Zone Sizing Summary for FCU-5 Project -Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:03PM Air System Information Air System Name FCU-5 Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 578.2 ft2 Location Miami IAP, Florida Zone CFM Sizing Sum of space airflow rates Space CFM Sizing Individual peak space loads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box an Airflow (CFM) : 0 Zone 1 820 820 1.42 0.0 - 0.0 - Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 17.7 Aug 1700 9.5 578.2 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible IMBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 01 Classroom 8/9 1 17.7 Aug 1700 820 9.5 578.2 1.42 •• ••• • " • • • •• • • • • • • • • . •• ••• •• • • • •• • ••• • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • •• • • • • • • ••• • • • ••• • • • • ••• • • Hourly Analysis Program 5.11 • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• 000 • • • ••• • • Page 2 of 3 Air System Design Load Summary for FCU-5 Projeci Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:03PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Aug 1700 COOLING OA DB / WB 89.9 °F / 76.7 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F / 38.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 98 ft2 2722 - 98 ft2 - - Wall Transmission 591 ft2 5276 - 591 ft2 4906 - Roof Transmission 0 ft2 0 - 0 ft2 0 - Window Transmission 98 ft2 1422 - 98 ft2 2540 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 46 ft2 368 - 46 ft2 657 - Floor Transmission 578 ft2 0 - 578 ft2 992 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 636 W 2170 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 578 W 1973 - 0 0 - People 12 2940 2460 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 5% 844 123 5% 455 0 » Total Zone Loads - 17714 2583 - 9550 0 Zone Conditioning - 16931 2583 - 9470 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 864 CFM 0 - 864 CFM 0 - Ventilation Load 189 CFM 2948 6483 189 CFM 4923 0 Supply Fan Load 864 CFM 320 - 864 CFM -320 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 886 - 5% 477 - » Total System Loads - 21085 9066 - 14551 0 Central Cooling Coil - 21085 9068 - 0 0 Central Heating Coil - 0 - - 14551 - » Total Conditioning - 21085 9068 - 14551 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads • • •• • • • • • • • • •• •• • • • •• • • • •• • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • •• • • • • • • • • • • • • Hourly Analysis Program 5.11 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • •• •• • • • • • • • • • • • Page 3 ;of 3 Air System Sizing Summary for FCU-6 Projec,i Name: 18-068 Miami Shores Community Church 07/05/2018 Prepared by: RPJ, Inc. 04:04PM Air System Information Air System Name FCU-6 Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 383.3 ft2 Location Miami IAP, Florida Sizing Calculation Information Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space loads Central Cooling Coil Sizing Data Total coil load 2.0 Tons Load occurs at Jul 1700 Total coil load 24.4 MBH OA DB / WB 89.9176.7 °F Sensible coil load 16.3 MBH Entering DB / WB 79.0 / 67.2 °F Coil CFM at Jul 1700 650 CFM Leaving DB / WB 55.8 / 54.8 °F Max block CFM 650 CFM Coil ADP 53.2 °F Sum of peak zone CFM 650 CFM Bypass Factor 0.100 Sensible heat ratio 0.667 Resulting RH 51 CFM/Ton 319.2 Design supply temp. 55.0 °F ft2/Ton 188.2 Zone T-stat Check 1 of 1 OK BTU/(hrft2) 63.7 Max zone temperature deviation 0.0 °F Water flow @ 10.0 °F rise N/A Central Heating Coil Sizing Data Max coil load 11.6 MBH Load occurs at Des Htg Coil CFM at Des Htg 650 CFM BTU/(hrft2) 30.2 Max coil CFM 650 CFM Ent. DB / Lvg DB 63.8 / 80.4 °F Water flow @ 20.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 650 CFM Fan motor BHP 0.09 BHP Standard CFM 650 CFM Fan motor kW 0.07 kW Actual max CFM/ft2 1.70 CFM/ft2 Fan static 0.50 in wg Outdoor Ventilation Air Data Design airflow CFM 166 CFM CFM/person 13.83 CFM/person CFM/ft2 0.43 CFM/ft2 • • • • • • • • • • • • • • • • • • • • • • • • • • • • •. • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 1B411118., . o-' '�\ No 63`3 aG-. , v l 0 r .s:Nt, u Hourly Analysis Program 5.11 • • • • • • • • • • • • • • • • • • • • • • 0•• • • • 0•• • • Page 1 'of 3 Zone Sizing Summary for FCU-6 Project !Jame: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:04PM Air System Information Air System Name FCU-6 Equipment Class SPLT AHU Air System Type SZCAV Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone Terminal Sizing Data Number of zones 1 Floor Area 383.3 ft2 Location Miami IAP, Florida Zone CFM Sizing . Sum of space airflow rates Space CFM Sizing Individual peak space Toads Zone Name Design Supply Airflow (CFM) Minimum Supply Airflow (CFM) Zone CFM/ft2 Reheat Coil Load (MBH) Reheat Coil Water gpm @ 20.0 °F Zone Htg Unit Coil Load (MBH) Zone Htg Unit Water gpm @ 20.0 °F Mixing Box Fan Airflow (CFM) 0 Zone 1 617 617 1.61 0.0 - 0.0 - Zone Peak Sensible Loads Zone Name Zone Cooling Sensible (MBH) Time of Peak Sensible Cooling Load Zone Heating Load (MBH) Zone Floor Area (ft2) Zone 1 13.3 Jul 1800 7.4 383.3 Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Peak Sensible Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 1 02 Classroom 11/12 1 13.3 Jul 1800 617 7.4 383.3 1.61 111.0 000 • • • • e 100 • • • • • • • • . •• .•• •• • • • •• • ••• • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 0410 • • • Hourly Analysis Program 5.11 000 • • • • 000 • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • 000 • • • 000 • • Page 2 ;of 3 Air System Design Load Summary for FCU-6 Project Name: 18-068 Miami Shores Community Church Prepared by: RPJ, Inc. 07/05/2018 04:04PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1700 COOLING OA DB / WB 89.9 °F / 76.7 °F HEATING DATA AT DES HTG HEATING OA DB / WB 46.0 °F 138.6 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 98 ft2 1515 - 98 ft2 - - Wall Transmission 399 ft2 3081 - 399 ft2 3314 - Roof Transmission 383 ft2 571 - 383 ft2 511 - Window Transmission 98 ft2 1422 - 98 ft2 2540 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 46 ft2 368 - 46 ft2 657 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 422 W 1439 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 383 W 1308 - 0 0 - People 12 2940 2460 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 5% 632 123 5% 351 0 » Total Zone Loads - 13274 2583 - 7373 0 Zone Conditioning - 12786 2583 - 7171 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 650 CFM 0 - 650 CFM 0 - Ventilation Load 166 CFM 2610 5551 166 CFM 4294 0 Supply Fan Load 650 CFM 241 - 650 CFM -241 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 664 - 5% 369 - » Total System Loads - 16300 8134 - 11593 0 Central Cooling Coil - 16300 8135 - 0 0 Central Heating Coil - 0 - - 11593 - » Total Conditioning - 16300 8135 - 11593 0 Key: Positive values are clg loads Negative values are htg Toads Positive values are htg loads Negative values are clg loads •• • • • • • • • • •• • • • • • • •• • •• • • • •• • • • •• • • • • • • • • • • • • • • • • • • • • • • d • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • d • • • • • • • • • • • • • • Hourly Analysis Program 5.11 • • • • • • • • • • • •• •• • • • •• d• • • • • • • ••• • • Page 3 of 3