EL-17-1936Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Pe mit Parcel Number Permit NO. EL-7-17-1' 936 Permit Type: Electrical - Residential Work Classification: Generator Permit Status: APPROVED Issue Date: 8121/2017 Expiration: 02/17/2018 Applicant 601 GRAND CONCOURSE Miami Shores, FL 1132060172140 Block: Lot: CARLOS FELIPE LEMOS Owner Information Address Phone Cell CARLOS FELIPE LEMOS 601 GRAND Concourse MIAMI SHORES FL 33138- 601 GRAND Concourse MIAMI SHORES FL 33138- Contractor(s) ELECTRICAL SERVICES JC INC Phone (305)244-8628 CeII Phone Valuation: Total Sq Feet: $ 2,500.00 0 Type of Work: INSTALL STANDBY GENERATOR Additional Info: Classification: Residential Scanning: 3 Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - Additions/Alterations Plan Review Fee Scanning Fee Technology Fee Total: Amount $1.80 $2.00 $2.00 $0.60 $100.00 $80.00 $9.00 $2.40 $197.80 Pay Date Pay Type Amt Paid Amt Due Invoice # EL-7-17-64721 08/21/2017 Credit Card $ 147.80 $ 50.00 07/28/2017 Credit Card $ 50.00 $ 0.00 Available Inspections: Inspection Type: Final Review Building Review Structural Review Electrical Review Planning Review Plumbing In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I ify t.. all t foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constru ion a th I - thorize the above -named contractor to do the work stated. August 21, 2017 orized gnature: Owner / Applicant / Contractor / Agent Date B ding ' epartment Copy August 21, 2017 1 4B.5\ R 3(>sA BUILDING PERMIT APPLICATION BUILDING ® ELECTRIC Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 ❑ ROOFING PLUMBING El MECHANICAL El PUBLIC WORKS JOB ADDRESS: 60 ( Gala CD/l)CiouRSe Master Permit No Sub Permit No. RECEIVED JUL 2 8 2017 FBC 20 ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑ CHANGE OF El CANCELLATION El SHOP CONTRACTOR DRAWINGS City: Miami Shores '/ County: Miami Dade Folio/Parcelth J/ 36706-017-2/ 1k Is the Building"`Historically Designated: Yes NO Occupancy Type: Load: Construction Type:kaVAT,4-Flood Zone: BFE: FFE: Zip: 33 / 3g OWNER: Name (Fee Simple Titleholder): OARLDS Fe/ipe Ge/Ll(7s Phone#: Address: �//J(d)/ ,2 ln-D (NnanU/QSe If City: M/ SJ 1)ie State: rL . Zip: 33/32 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: EZ C.7K /C/- L J pj2 IiCpS v C 1/t)C Address: V94 / pa) /02 Ave City: M/ei%i1J State: I L • Qualifier Name: 3iJA/i� C ii'D�T/ ri-D State Certification or Registration #: EC 13006560 Phone#:,g0S--iti -R022 hp: 334.5 .� Phone#: 30S- o�4' (oo4 2 Certificate of Competency #: DESIGNER: Architect/Engineer: -Phone#: Address: ,/ City: State: Zip: Value of Work for this Permit: $ vaa? 6, 4 ,-JG 0 Square/Unear Footage of Work: Type of Work: ❑ Addition IS Alteration ❑ New 0 Repair/Replace ❑ Demolition Description of Work: Tt16774-LL S; 'i DBy I1Pilee4-704e Specify color o color thru tile: -�1 Submittal Fee $ Permit Fee $ 'W • a) CCF $ Scanning Fee $ Radon Fee $ DBPR $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ 1 �� (Revised02/24/2014) CO/CC $ Notary $ OD Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address city State tip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS. AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR 'FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of o building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of su -osted notice, the inspection will not be approved and a reinspect fee will be charged. SignatureX c - �—�----fir--- . OWNER or'AGENT The foregoing instrument was acknowledged before me this day of I l)/ , 20 1 1 , by CGst0.5 I C M oS , who is personally known to me or who has produced Octv-ca' L is c n S as identification and who did take an oath. NOTARY PUBLIC Sign: /ice Print:.'OSTL4\ Seal: ,.Q`6yl 10; Josefina Jara :. ��, �'= Commission # GG109716 -�` = Expires: May 30, 2021 APPROVED BY (Revised02/24/2014) Signature CONTRACTOR The foregoing instrument was acknowledged before me this le} day of taily ,20 ,by TVYsc ii FI r< < la , who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBUC: Sign: ` Print: I v Seal: Plans Examiner Structural Review 40* , Josefina Jara �•� �_-_ Commission # GG109716 if Expires: May 30, 2021 ;„llll 1 11 (fld' f i nita 7/ (7 Zoning Clerk Property Search Application - Miami -Dade County Summary Report Property Information Folio: 11-3206-017-2140 Property Address: 601 GRAND CONC Miami Shores, FL 33138-2473 Owner CARLOS FELIPE LEMOS NICOLE OLINGER BROFMAN Mailing Address 601 GRAND CONCOURSE MIAMI SHORES, FL 33138 USA PA Primary Zone 1300 SGL FAMILY - 2801-3000 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds/Baths/Half 3/2/1 Floors 2 Living Units 1 Actual Area 2,968 Sq.Ft Living Area 2,244 Sq.Ft Adjusted Area 2,396 Sq.Ft Lot Size 14,324.7 Sq.Ft Year Built 1938 Assessment Information Year 2017 2016 2015 Land Value $504,147 $458,315 $315,580 Building Value $391,506 $396,059 $188,996 XF Value $10,716 $10,828 $8,054 Market Value $906,369 $865,202 $512,630 Assessed Value $883,371 $865,202 $382,386 Benefits Information Benefit Type 2017 2016 2015 Save Our Homes Cap Assessment Reduction $22,998 $130,244 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 65342PB15-14 AMD PL MIAMI SHORES SEC 4 LOT 13 & W2OFT LOT 14 BLK 103 LOT SIZE 110.190 X 130 OR 19293-1009 09 2000 1 Page 1 of 1 Generated On . 7/28/2017 Taxable Value Information 2017 20161 2015 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $833,371 $815,202 $332,386 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value $858,371 $840,202 $357,386 City Exemption Value $50,000 $50,000 $50,000 Taxable Value $833,371 $815,202 $332,386 Regional Exemption Value J $50,000 $50,000 $50,000 $833,371 $815,202 $332,386 Taxable Value Sales Information Previous Sale Price OR Book - Pa 9a Qualification Description 07/15/2015 $1,250,000 29699 3310 Qual by exam of deed 10/16/2009 $473,500 27059 4814 Qual by exam of deed 09/01/2000 $325,000 19293 1009 Sales which are qualified 01/01/1997 $0 18108- 4884 Sales which are disqualified as a result of examination of the deed The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: http://www.miamidade.gov/propertysearch/ 7/28/2017 a Congratulations! • With this license yyocru become one of the nearly ono million Floridians licensed by tiae Department 6f Business and Professional Regulation, Our professibnats and businesses range from.architects to yacht brokers, from boxers to barbeque .restaurants, and they keep Florida's economy strong. Eatery day we work to improve the way we do business in order to serve you better. For information about our services, please log onto wwvir myfloridalicerise.com_ There you can find rnore Information about our divisions and the regulations that impact you, subscribe to department newsletters and learn, more about . the Department's initiatives.. Our mission at the Department is: License EfRciently, Regulate Fairly. We constantly strive to serve you better so that you can Serve your customers. Thank you for doing business in Pbrida, and congratulations on your new license! RICK SCOTt, GOVERNOR RC 13006560 STATE or FLORIDA DEPARTMENT OF BUSINESS AND PROFESS d RCULATION EC13005560 • ay4. , `� JSE11`� ``� �O,3/14/2016 CERTIFIED ELF& PORTILLO, Jt1AIt,,, ELECTRICAL sEltiht, L •CONTl ctoR f. 1s CERTIFIED under the provislons.of Ch.468 FS_ flEOrs.uon data A(JC 71, Oie L16o$t400pti619 DETACH HERE KEN LAWSON; SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION ELECTRICAL CONTRACTORS LICENSING BOARD The ELECTRICAL CONTRACTOR Named below IS CERTIFIED Under the provisions of Chappter 489 FS. Expiration date: AUG 31, 2018 PORTILLO, JUAN CARLO$.:. . ELECTRICAL SERVICE-S:', 4401 SW 102ND AVENUJii zl 4x ,k?; ;:?;;': " MiAMI . FFL 334'. • • • c. 15. ::... ':.i I." ' • .'1C .je. tiy,t lay .;1• v 08/14/2010 �'"," �"` • DISPLAY AS REQUIRED BY LAW .octal Business Tax Receip Miami —Dade County, State of Flotilla =THISIS NOT ABILL -DO NOT PAY 04.1547 uSINSSS NAME/LOCATION `-ECTRICAL SERVICES JC INC 201 SW 102 AVE IA11,1I FL 33165 MUER ECFRICAL SERVICES JC INC -' i er(s) 1 RE No_ EXPIRES. • RENEWAL . •stParemBER.30,.2017 7326015/ Must be displayed at pace of lauslnete PUra{iant t0 County Code Chapter BA -Art 9 & 10 PAYNWN1 Ft4m1yui BY TAX COLt:PGT,OR :$75.00 07/18/2016 •CHEcK21- 1041.9t014 Thls Local Business Tax Receipt only confines pavnient Odle Boat kfiaieross Tax: Me Receipt's not a Iiioeate, !amok or a certification of tag holder's goaliflcaHons. to do business:- Holder meat comply *Mt any geventmenmi • SEC_ TYFlg CIF ISUSF4g*S • 196 ELECTRICAL CONTRACTOR Eel3605500 SEQ # L1608140004818 ,�mIc CERTIFICATE OF LIABILITY INSURANCE DAM ntma ;"'' THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT AIETWAEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: lithe oerdOcala holder to an ADDITIONAL INSURED, the pollay(I.e) must be Mdoraad. Ir SUBROGATION W WAIVED, subject to . the tenna and condldons Orthe Rangy. tartan polldas may require an anaorsemaDL A slidamont on Elk torINIcata do.. not wear Vita to Ma cerelloate Nadir In IN0 Of ouch ondor mont(e). PRODUCER Pandora Insurance 14578 SW Ss! Mlernl, FL 33184 Phone e06) 231-0895 Fax 06') 875-8034 r+ 1 q t4U*a Garcia till • . �. (305) 2314898 La.: (305) 675-8034 .,, : _ niuncespausorainstsenco.com INSUREToia1 APPORI1IMe DOVCRAVE _Wail mum Ascendant Carnmenc l Insurance MIMED ELECTRICAL SERVICES JC INC 4401 SW 102 AVE MIAMI FL 3316S Ntu i .o i Associated Industries Insurance Company !MUM D : Mrsum ID mu mi: THIS 1S TO CERTIFY TthAT THE POLICIES OF INSUM NcL LISTED BELOW {TRYST 8 ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICMEIp. NOTWITHSTANDING ANY REOUIREMENr, TERM OR cONDmQN OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY 8E ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES OFACR18ED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CENDttIONB OF SUCH POLICIES_ UNITS BN0iM'I MAY HAVE BEEN .REDUCED BY PAID CLAIM$. . 2 sae A TYPE OP INleURANCE Anolselaa mot Iwo • PQI JCY MOM ini5=1 AdiThIck um= — - - CONWERCr.I GEFORAL UAatuiY ❑ CIAII-MADE OCCUR CL-48540-2 07/01/ i017 07/01/2018 4 1,000,000.QD rdeD ExP Wna,.vw.oID $ 8.004.40 Pa:RBQNai, a Arm INJURY $ 1,000,000.00 $ 2,000,000.00 GEM. AGGReGATEGIft TPPp[I=fet 0 WC GENERAL At L AR • potmv • W PRpotulre-pp�'oPAoa 1 1,000,000.00 ❑� s ' • AUmVOBILE UAINUTY 1J ANTAure 0 ❑ eriCurrUP UTBODti r0 HIRED Amos 0 pg" .3_E 'ut40Ia oar a t100ULY INJURY (Per perm) 1 QE.ptidrnp s 0 s S . . . ' `'❑ Q uaraRELA UMOCOlAZ ❑ Min "MI CLAND4ORDE EACH OOCURAENGE $ „ A0OREOATE a nm; Q mowsWORMS " B ' COIUMMLosaaa 1 uAA �u,�n- I�E�00.uD�' glionogoof In NH) arn, dmalibe wider DESSORPTION OF OPEIATTONSbona trlN— NIA AWC1071002 10/30/2018 10/30/2017 ❑ eTIASiro{ 0 �R El- EACH ACCIO rf s 1,000,000,00 S 1,000,000.00 I 4 P1SP.ASE - EA EIIP EL DREAM - POLICY LAW a 1,000,000.00 COOCRIPfON License OF OPI XATIONS/ LOCATIONS / MIMES (Mach : EC130035110 • AMMO set. Makmel Rwmb &h..d% C mop spies M pgrlBed) CANCELLATION Meal Shores Village 10050 NE 2n0 Are Mlarnt SliOns, FL. 33138 Phone: 305-795-2207 I Paz: 305-755-0972 ENONL,D ANY OF THE AAOvE D11CR1BED POLICIES LIE CANCELLED. BEFORE TIE EXPIRATION PATE THEREOF, NOTES WILL. BE DIH.IVERED IN Ac@ORDANCE WITH THE POLICY PROVISIONS, AUTNOR D R1PRIDOENTATNE ACOND 25 (2014(011 OP • 19E3-2014 ACORD CORPORATION. All rights reserved. The ACORD name and logo tine registered marts of ACORD U.S. DEPARTMENT OF HOMELAND SECURITY Fede'r'al EP;k3rgenct Management Agency National Flood Insurance Program 'Job: 17-728 • • • •• • • • • • • • • • • • • ELEVATION CERTIFICATE • • . •.. 0MB No, 1060 V008 CX13,1 raion Bate* November 30, 2018 • • . . . ... Important: Follow the instructions on pag�S 1-6. • •' . •' • • • • • • • • • . • . . . . . . . Copy all pages of this Elevation Certificate and all attachments for (1) community official, (Q� fnsUrance 4 trtphipany,:and (3) building owner. SECTION A - PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name •.• • ••Pol�s Carlos Felipe Lemos & Nicole Olinger Brofman • • • • • • • •• • • •er Nu rtbi•• •• • ' • _ A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route anti : : Box No. 601 Grand Concourse • • • ' • • company LAIC Number: City State ZIP Code Miami Shores Florida 33183 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) PB 15-14 Lot 13 & W2OFT Lot 14, Block 103 of: "AMD PL MIAMI SHORES SEC 4", of Public Records of Miami -Dade Co., FL A4. Building Use (e.g., A5. Latitude/Longitude: A6. Attach at least 2 A7. Building Diagram A8. For a building with a) Square footage b) Number of permanent c) Total net area d) Engineered A9. For a building with a) Square footage b) Number of permanent c) Total net area d) Engineered Residential, Non -Residential, Addition, Lat. 25° 52' 02.48" N Long. Accessory, etc.) RESIDENTIAL 80° 11' 06.68" W Horizontal Datum: obtain flood insurance. 1.0 foot above adjacent above adjacent grade ❑ NAD 1927 grade x NAD 1983 3 photographs of the building if the Number 8 Certificate is being used to 2,396 sq ft a crawlspace of crawlspace flood of flood openings flood openings? an attached of attached flood of flood openings flood openings? or enclosure(s): or enclosure(s) openings in the crawlspace in A8.b 289 sq or enclosure(s) within in ft within 1.0 foot sq in 0 sq ❑Yes x No garage: garage 0 openings in the attached garage in A9.b 0 ❑Yes x No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number Village of Miami Shores - 120652 B2. County Name Miami -Dade County B3. State Florida B4. Map/Panel Number 12086C - 0306 B5. Suffix L B6. FIRM Index Date 09/11/2009 B7. FIRM Panel Effective/ Revised Date 09/11/2009 B8. Flood Zone(s) "X" B9. Base Flood Elevation(s) (Zone AO, use Base Flood Depth) N/A B10. Indicate the source ❑FIS Profile B11. Indicate elevation B12. Is the building Designation Date: of the Base Flood Elevation (BFE) Community Determined for BFE in Item B9: Coastal Barrier Resources ❑ CBRS data or base flood depth entered in Item B9: ❑Other/Source: x FIRM datum used located in a 1929 ❑ NAVD 1988 ❑ Other/Source: (CBRS) area or Otherwise Protected Area (OPA)? ❑ OPA x NGVD System Yes x No FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 1 of 6 ... • • • ••• •• • ELEVATION CE 2T1FtC3ij • .•••; OMB No. 1660-0008 Expiration Date: Nivember480, 2018 IMPORTANT: In theWsifaces' copy the 'corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. 601 Grand Conc3 rte '. ••• ••• :•. •.• Policy Number: City •• ••w. �. •'. • • State ZIP Code • • • . Miami Shores • • • • • • •. . ".' Florida 33183 Company NAIC Number SECTION C — _BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) 00 000 am - - • 1. Building elevations art:IA/ ji rn:: *A new Elevation Oer4ifioat; will C2. Elevations — Zones A1—A30, AE, Complete Items C2.a—h below Benchmark Utilized: N-802 •• Rico ;'• Oonstruction Drawings* ❑ Building Under Construction* x Finished Construction te.'re4uifed when construction of the building is complete. AH, A (with BFE), VE, V1—V30, V (with BFE), AR, AR/A, AR/AE, according to the building diagram specified in Item A7. In Puerto ELEV +8.97' Vertical Datum: NGVD 1929 AR/A1—A30, AR/AH, AR/AO. only, enter meters. Indicate elevation datum used for ❑ NAVD elevations floor horizontal of slab) machinery grade at lowest the elevations in items a) through h) below. 1988 ❑Other/Source: x NGVD 1929 Datum used for building a) Top of bottom floor (including b) Top of the next higher c) Bottom of the lowest d) Attached garage (top e) Lowest elevation of (Describe type of equipment f) Lowest adjacent (finished) g) Highest adjacent (finished) h) Lowest adjacent grade structural support must be the same as that used for the BFE. Check the measurement used. basement, crawlspace, or enclosure floor) 9.15 Qeet [meters 10.37 X feet ❑ meters structural member (V Zones only) N/A ❑ feet ❑ meters N/A ❑ feet ❑ meters or equipment servicing the building 9.50 X feet ❑ meters and location in Comments) next to building (LAG) 9.10 X feet ❑ m eters grade next to building (HAG) 9.27 X feet ❑ meters elevation of deck or stairs, including N/A ❑feet ❑ meters SECTION D — SURVEYOR, ENGINEER. OR ARCHITECT CERTIFICATION This certification is to be signed and / certify that the information on this statement may be punishable by fine Were latitude and longitude in Section sealed by a land surveyor, engineer, or architect authorized by Certificate represents my best efforts to interpret the data available. or imprisonment under 18 U.S. Code, Section 1001. law to certify elevation information. I understand that any false ❑Check here if attachments. A provided by a licensed land surveyor? x Yes No Certifier's Name License Number Armando F. Alvarez #5526 0 F • A4 Title Surveyor & Mapper SE NV �� Q G`O '�<c` ., ri 5526- 1' -,o. STATE.OF 4. m FLORIDA ,, s, - oi, 1,r.7, Company Name AFA & Company, Inc. Address 13050 SW 133rd Court City Miami State ZIP Code Florida 33186 Signature ,givmawuia Date Telephone r/ 5526 07/24/2017 (305) 234-0588 Copy all pages of thi do rtifi to and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) Average Crown Road + 9.27' C2.e) NC SLAB ELEV + 9.50' (NC SLAB LOCATED ON THE LEFT SIDE OF THE RES) A5) COORDINATES OBTAINED FROM GOOGLE EARTH FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6 ELEVATION CERTIFICATE BUILDING PHOTOGRAPHS OMB No. 1660-0008 See Instructions for Item A6. • • • E43,yratgn Lte:.November 30, 2018 • • • •4. IMPORTANT: In these spaces, copy the corresponding information from Section A. : : • PM IaISUItANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and lox N. • • I 601 Grand Concourse Ffolicy•Numl?er: • • City State ZIP Code. • • . .: i Miami Shores Florida 33183 • • • • • • 'Gorr any N iC Niumber • • •• • • • • • If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "ReV.tiew";:a ciiregjirrd,•"Fright Side View" and "Left Side View." When applicable, photographs must show the foundation with represenfetipe•exprules:of the•ffood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this pag%,se the LositisuatiornP1er .. .,. } i. I ,tily_ • I .f'. ✓,`4 .. ii 1.1 rr �R t. • • .nib, '.. ,.-.) {• �• .fir ` al IP ,w' 1 , ,. ;�11 to a ^IIMINIIM Photo One Caption FRONT VIEW (07/24/2017) • tf • ..s - - Photo Two Caption REAR VIEW f• 1111 �• 1 (07/24/2017) FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 5 of 6 IMPORTANT: In these spaces, copy the corresponding information from Section A.:. .: •: • FOR I1:1it..44 t COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box Nei. ; 601 Grand Concourse • • • • Poliyilumier: ; • • • • • • • • City State ZIP Code Miami Shores Florida 33183 . • • • •: •—• • . Company NAIC , • • • • • • • • Number • •: • • • • • • • • • • • • • • • ••• • • If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View." photographs must show the foundation with representative examples of the flood openinosrory a its•,v iodiotin • OOOOO • •• • • • • all photographs When applicable, Section A8. • a7i►' •�`', i . 's .r f. , • , II , W 1 1 , •. Photo One Caption RIGHT VIEW (07/24/2017) • e • • ' • }', :' fr r , , +►.. 4 StJ;s Photo Two Caption LEFT VIEW (07/24/2017) FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 6 of 6 16/20/22 kW • • ••• • • • ••• •• •• • • •• • •• •• • • GgN a OAC` • ••• • • •• ••• • •• •• • •• •• •• • •• •• •• ;•GUAHD(AIVa.SERIES Residential Standby Generators .... . . .. .. •• ;•;Air; ooI 8 Gas Engine • • • • • • • • • • • • • • • • • • • • • INCLUDES: • True Power'"" Electrical Technology • Two Line LCD Multilingual Digital Evolution TM Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. • Electronic Governor • System Status & Maintenance Interval LED Indicators • Sound Attenuated Enclosure • Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Capability to be installed within 18" (457 mm) of a building* Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-0, G007042-0 (Aluminum - Bisque) - 22 kW 60 Hz GENERAC cuts QUILT TEST Note: CUL certification only applies to unbundled units and units packaged with pre -wired switches. Units packaged with the Smart Switch are UL certified in the *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: PROTOTYPE TESTED NEMA MG1-22 EVALUATION SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY W GENERAC PROMISE O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. it provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1%. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. ISO * 55fl In the USA ui.p dome. e? epn 9.rte 16/20/22 kW Engine • Generac G-Force design • •"Spiny-lok" cast iron cylinder walls �• Electronic ignition/spark advance • Full pressure lubrication system • Low oil pressure shutdown system • High temperature shutdown • • •••• • • • ••• c. • • •• • •••.G1 • • • • • • •--its.-..,... features and benefits • • • • •�• •a• •• • • • •• • • • • • • • • • • • • • • • Maximizes engine "breathing" for increased fuel efficiency. Plateau honedcylinderwa4l9aiad plasma moIrnngs helps the engine run cooler, reducing oil consumption resulting in longer engine life. Rigid construction and added durability provide long engine life.• • • • • • • • • • .. These features combine to assure smooth, quick starting every time. • • • • • • • • • •• • • Pressurized lubrication to all vital bearings means better performancg,,less j 1aipteit udb a:d IQng:roagigeJi?e. Now featur- ing up to a 2 year/200 hour oil change interval. Shutdown protection prevents catastrophic engine damage due to low oil. Prevents damage due to overheating. Generator • Revolving field • Skewed stator • Displaced phase excitation • Automatic voltage regulation • UL 2200 listed Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. Produces a smooth output waveform for compatibility with electronic equipment. Maximizes motor starting capability. Regulates the output voltage to ±1 % prevents damaging voltage spikes. For your safety. Transfer Switch (if applicable) • Fully automatic • NEMA 3R • Remote mounting Transfers your vital electrical loads to the energized source of power. Can be installed inside or outside for maximum flexibility. Mounts near your existing distribution panel for simple, low-cost installation. Evolution-" Controls • Auto/Manual/0ff illuminated buttons • Two-line LCD multilingual display • Sealed, raised buttons • Utility voltage sensing • Generator voltage sensing • Utility interrupt delay • Engine warm-up • Engine cool -down • Programmable exercise • Smart battery charger • Main line circuit breaker • Electronic governor Selects the operating mode and provides easy, at -a -glance status indication in any condition. Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. Smooth, weather -resistant user interface for programming and operations. Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. Constantly monitors generator voltage to ensure the cleanest power delivered to the home. Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. Ensures engine is ready to'assume the load, setpoint approximately 5 seconds. Allows engine to cool prior to shutdown, setpoint approximately 1 minute. Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. Protects generator from overload. Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure • Enclosed critical grade muffler • Small, compact, attractive Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. Quiet; critical grade muffler is mounted inside the unit to prevent injuries. Makes for an easy, eye appealing installation, as close as 18" away from a building. Installation System • 1 ft (305 mm) flexible fuel line connector • Direct -to -dirt composite mounting pad • Integral sediment trap Absorbs any generator vibration when connected to rigid pipe. Complex lattice design prevents settling or sinking of the generator system. Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. 16/20/22 kW • • • • • • • • • • • • ••• •• •• • • • • • • • • . • .:17E11E ERAC' • • ••• • ._. .•_.---�., specifications Generator Model [Rated Maximum Continuous Power Capacity (LP) Rated Maximum Continuous Power Capacity (NG) iRated Voltage • • • • • • • • • • 0007035-0, GOO )31 0,: G007031-0, 00071139-0 • g001042-0, G007043-0 G007037-0 (16 kW) • •(2QkW)' " (22 kW) Rated Maximum Continuous Load Current — 240 Volts (LP/NG) rrTotal Harmonic Distortion Main Line Circuit Breaker [Phase Number of Rotor Poles (Rated AC Frequency Power Factor tarry (not included) 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum J Unit Weight (lb/kg) 406/186 448/203 466/211 (Dimensions (L x W x H) in/mm 48 x 25 x 29/1218 x 6387732 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal Toad" 66 Sound output io dB(A) at 23 ft (7 m) with generator in 0uiet-Test"' [ow -speed exercise mode"" 58 Exercise duration 5 min 16,000 Watts' 20,000 Watts' 22,000" 16,000 Watts* • • • • 18,0.00 Wittier... • • 19,500 240 • • • • 240 • • • • 240 66.6/66.6 • . : •: :83.3/7: • • : • • • 91.6/81.3 Less than 5% • •'!; :"List Grant%: -: • • • . • Less than 5% 70 Amp 100 Amp 100 Amp 1 1 1 2 2 2 60 Hz 60 Hz' " 60Hi J 1.0 1.0 1.0 66 .58-- 5 min 67 58 "l 5 min Engine Type of Engine !Number of Cylinders GENERAC G-Force 1000 Series GENERAC G-Force 1000 Series GENERAC G-Force 1000 Series Displacement [Cylinder Block _ _ Valve Arrangement Ignition System Governor System 2 999 cc 2 2 LComp "lion Ratio Starter Oil Capacity Including Filter Operating rpm Overhead Valve Solid-state w[Mag Electronic 9.5:1 999 cc Aluminum w/ Cast Iron Sleeve Overhead Valve neto Sold -state w/ Magneto Electronic 9.5:1 12 Vdc 12 Vdc Approx. 1.9 qt/1.8 L Approx.1.9 gt/1.8 L 3,600 3,600 999 cc Overhead Valve Solid-state w/ Mag'" neto 1 Electronic 9.51'T`-'� ApproxT1.9 1/1'8 L 3,600 Fuel Consumption Natural Gas Liquid Propane 218 (6.17) 204 (5.78) 216 (6.12) 309 (8.75) 301 (8.78) 310 (8.78) 91.6 (2.52) [9.53] 86 (2.37) [8.99] 93.2 (2.56) [9.70] Full Load 106.8 (2.94) [11.11] 129.6 (3.56) [13`48] 140 (3.87) [14.65]_ Note: Fuel pipe must be sized for lull load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7° water column (7-13 mm mercury) for natural gas,10-12" water column (19-22 mm mercury) for LP gas. For Btu content, multiply ft3/hr x 2500 (LP) or ft3/hr x 1000 (NG). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG) -�r Controls 2-Line Plain Text Multilingual LCD Display [Mode Buttons:Auto _ Manual [Off ft3/hr (m3/hr) 1/2 Load Full Load ft3/hr (gal/hr) [I/hrl 1/2 Load Simple user interface for ease of operation. Automatic Start on Utility failure. 7 day exerciser. Start with starter control, unit stays on. If utility fails, transfer to load takes place. Ready to RurvMaintenance Messages [Engine Run Hours Indication Programmable start delay between 2-1500 seconds [tltility Voltage Loss/Return to Utility Adjustable (Brownout Setting) Future Set Capable Exerciser/Exercise Set Error Warning 1 Stops unit. Power is removed. Control and charger still operate. Standard Standaid [RuWAIarnVMaintenance Loijs Engine Start Sequence [Starter Lock -out Smart Battery Charger (Charger Fault/Missing AC Warning _ Low Battery/Battery Problem Protection and Battery Condition Indication Automatic Voltage Regulation with Over r and UrideTVoRgtection Under-Frequency/Overload/Stepper Overcurrent Protection (Safety Fulreed#51Problem Protection Automatic Low Oil Pressure/High Oil Temperature Shutdown [0vercranWOverspeed (@ 72 Hz)/rpm Sense Loss Shutdown High Engine Temperature Shutdown [Internal Fault/Incorrect Wiring Protection - Common External Fault Capability (Field Upgradabie Firmware Standard (programmable by dealer only) From 140-171 V/190-216 V 1 Standard 50 Events Each Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). Starter cannot re-engage until 5 sec after engine has stopped. j Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard 1 1 "Sand levels are taken from the front of the generator. Sound levels taken from other sides of the generator maybe higher depending on installation parameters. Rating definitions - Standby: Applicable for supplying emergency power for the duration of ee utility power outage. No overload capability is available tor this rating. (Ali ratings in accordance with BS5514,1503046 and DIN6271). ' Masntxrnr Idlovolt amps and current are subject to and limited by such factors as fuel Btuftega)ale content, ambient lonperahre, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,003 teet (304.8 meters) above sea level; and also will decease about 1 percent for each 6 °C (10 °F) above 16 °C (60 `F). N N N CO T'" 3 of 5 16/20/22 kW Limited Circuits Switch Features • 16 circuits. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load, 100% equipment rated, both inductive and resistive. • 2 pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1" standard, tandem, GFCI and AFC' breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions 200 Amps 120/240,1 e Open Transition Service Rated Height Width Depth H1 H2 WI W2 in 27.24 30.0 11.4 13.5 7.09 mm 692.0 762.4 289.0 343.0 180.0 Note: The 50 amp switch is flush mountable. H1 and W1 refer to mounting hole spacing. H2 and W2 are cover dimensions. H3 and W3 are the enclosure dimensions without cover. Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 2/0-#14 2/0-#14 • • •• •• • • • • • • • ••• • • • •• •• • ' J switch siphons ••• • • • • • • • • • • • • _ • • • • • • • • • Model • • • • 6007036-0 (26kWt • v. a•.-•-•-- •«..�•�•�,.p.® [Nd:OOfP0I0S • • • • • • 2 • • • •""' Current Rating (Amps) 100 (Voltage Rating (VAC) 120/240,10 Utility Voltage Monitor (Fixed • • • •� •� • • s • • • --'"• • L -Pick-up • • 016 • -Dropout • • • • • • • • 05% : LRr elurn to Utility" • • •`• ••—p•imin! see • Exerciser bi-weekly for 12 minutes*t Standard i3L Listed Total of Pre -wired Circuits No. 15 A 120 V No. 20 A 120 V No. 20 A 240 V No. 30 A 240 V No.'40 A 240 V No. 50 A 240 V Tandem Breaker Capabifibes Standard 16 5 5 1 1 1 8 spaces Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts *Function of Evolution Controller Exercise can be set to weekly or monthly I- DEPTH -I HI W2 -1 10,000 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of Ioad, 100% equipment rated, both inductive and resis- tive. • Up to four more large (120/240 VAC) loads can be managed when used in con- junction with 50 amp Power Management Modules (PMM**). • 2 pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240, le Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 27.24 30.0 11.4 13.5 7.09 mm 692.0 762.4 289.0 343.0 180.0 Model rNo. of Poles__ Current Rating (Amps) [Voltage Rating (VAC) Utility Voltage Monitor (Fixed)" -Pick-up -Dropout G007037-0 (16 kW)/0007039-0 (20 kW)/ G007043-0 (22 kW) 2 J 200 120/240,10 80% 65% LR[ urn to Utility" approx.113 sec Exerciser weekly for 12 minutes* Standard ULLisied- S ndard Enclosure Type NEMA/UL 3R Cucud Brea r Protected ,000 Lug Range 250 MCM - #6 *Function of Evolution Controller DEPTH H2 w1� HI -- w2 • • 16/20/22 kW •. • available accessories Model # - Product Description • •• •• • - ' • • • • • • • • •••_• G006463-4 Mobile Link- • •••--,. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change in the generators status eocure. Availabig in:11B J1.% erfly. • • • •_ • • G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the sy tter ,. Generac rfertir rtcommendgd 26R wet cell battery for use with all air-cooled standby product Eexcludinb PowerPaet®,. • • • • • G007101-0 Battery Pad Warmer The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0°F. (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil fitter. Recommended for use if the temperature regularly falls below 0°F. G007103-0 Breather Warmer The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch Contact Kit The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load you may not need. Not compatible with 50 amp pre -wired switches. G007027-0 - Bisque Fascia Base Wrap Kit (Standard on 22 kW) The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. G005703-0 - Bisque Paint Kit If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Module (50 Amps) Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its power management capabilities. It provides additional power management flexibility not found in any other power management system. dimensions & UPCs Wig.; 12e,J 1 01 643mm r2E.6In) Dimensions shown are approximate. Refer to installation manual for exact dimensions. D0 NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. 121$ mm ru.° In) 1232 m° pe.s M LEFT SLOE VIEW FRONT VIEW GENERAL® Model UPC G007035-0 696471070354 G007036-0 696471070361 0007037-0 696471070378 0007038-0 696471070385 G007039-0 696471070392 0007042-0 696471070422 0007043-0 696471070439 Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 02016 Generac Power Systems, Inc. All rights reserved. At specifications are subject to change without notice. Part No. 10000000194-C 08/18/16 0AW1 a 0 d 0 O m J Lot 12, Block 103 0- a • LL :,5 Z • 3 P, r- / LL .. ••• cy • • •• .• • • • •v_" `.fir • • • • • • • • ••• • • • • •O_k • • • • • • aJ • • • • • •.• N18'04 29 • • • • •r • • ••• • S027616„ • • • North� r east 6th �4 venue ated q/`, ePha,1 Pay em Per Pe 15kanw-Oad 71> II 0 tL in, 10.76' Xy 29.05' gy 11.32' ., y Nh3 11411 I- 20238. Q\ J L JUL 282011 :ujJtL1;I;U CCM?1.IA E. wliii h ..TE Ww COUNTY RULES 4ND REG '!..A 1 (. a • \,° v\, ' cV 5 V 0 ct0► 5Iv\ Florida Power House, Inc - 12300 Sw 117th Ct Miami, FI 33186 License #LPG276O6 . . . . . .. • .... . • • • • • .. .... ... . • • •• • • •• • •• • • •. •. • • • • ••• • • • • • • • • • • • •• • ' . Vara � %' Commiis�sonn$:GG109716 % • "' 1 Expires: May 30, 2021 a ff4.„.�' Bonded thru Aaron otary • • *AII equipment is EXISTING unless otherwise noted as New. New Ground for Generator Frame only - #6 Cu to Ground Rod Also Fuel Pipe as per NEC 250.104 B • • ••• • •• •• • • • House' 200 Amp Meter Compaq • • • • -New 22kw Gen in WP Enclosure with 100 amp-2 Pole 240V-CB Gen • • • • • • • #4 CU New 3-#2AWG& 1 - #8 THWN (CU) in 1-1/4" Cond. CWP • • • • • • • • • ••• •• •• • •• • • •• •• • •• ••• •• • • • • • • • • 0 • • • • ••• INT EXT 41--0-Garage • • • ••• •• • • • ••• • •• •• • • • •• •• •• • • • • • •••• •• ••• • • • • • •• ••• •• • • • • • • 200A CB • •• • •• 1` • • • •• 3 - #2/0 AWG (CU) + 1- #6 THWN (Cu)(G) in 2" Cond. Ea. S.E. "200" Amp ATS INT INT Garage411-11" 1st Panel "A" 200 A 3#2/0 AWG (CU) Electrical Riser Diagram N.T.S General Load: Qty Description VIA 2244 Square feet (under air) @3v/a per sq foot: 6,732 2 Small Appliance Outlets : 3,000 1 Gas Hot Water Heater Igniter : 300 1 Washer : 1,500 1 Dryer : 4,500 1 Well Pump : 1,500 1 Refridgerator : 1,200 1 Microwave : 1,000 1 Gas Range : 500 1 Sprinkler Pump : 1,500 1 Garage Door Openers : 700 1 Dishwasher :1,200 1 Disposal : 600 Total General Load 24,232 First 10 kVA at 100% 10,000 Remainder at 40% 5,693 Subtotal General Load 15.693 No. of Units Air Conditioning I Heating VIA 1 A/C Unit 1 @ 100% 3,500 1 A/C Unit 2 @ 100% 2,500 Total A/C Load : 6000 Total Connected Load : 21,693 Total Connected Amps : 90.39 Floor Panel 100 A Panel 80 A 3-4AWG & 1 - #8 THWN (CU) in 1-1/4" Cond. 3 - 3 AWG & 1- #8 THWN (CU) in 1-1/4" Cond. Generator Power Requirement Phase Application Voltage Total Demand Amps Power Factor Watts Single 0 240v 90.39 1 21693 Total Generator KW into AMPS 22000 W 91.667 amps Total Demand Total Amps Available Total Amps to Shed 90.39 91.667 amps 0 Loads to be Shed (Watts) * see Ngtg 1 Amps Total *Note 1: Load Shedding will not be required. Total Amps to Shed 0 Total Gen Amps 91.667 Amps Total Managed Load 0 Total Gen Load After Shed 90.39 Amps 1. Bond Generator Frame and Gas Pipe only 2. Wire Generator as non-seperately derived system 3. Generator frame to be grounded as per NEC 250 4. Fuel pipe shall be bonded as per NEC 250-104 (B) 5. A permanent sign shall be placed at the electrical service entrance equipment that indicates the location of on -site optional standby power source 6. A permanent sign shall be placed at the transfer switch location indicating the sequence of operation to start the generator and transfer of the electrical Toads 7. Transfer switch is a non-seperately derived system *AII Equipment and Devices Shall be Mounted Above Flood Criteria as per chapter 11C-5(F)(4) ALL MAINS HAVE TO BE GROUPED AS PER NEC 230.72, 230.70, 225.31, 225.34. (SUITABLE FOR SERVICE EQUIPMENT NEC 225.6) TRANSFER SWITCH IS A 200A S.E. RATED SWITCH WITH A 200A CB THAT CAN BE DISCONNECTED BY MANUALLY TURNING OFF THE CB. A !il .,, Josefina Jara ,.�__ Commission # GG109716 "= Expires: May 30, 2021 ��ia /ftll\U�� Bonded tiro Aaron Notary LEMOS RESIDENCE - 601 GRAND CONCOURSE • • ••• • • • ••• •• •• • . • •• •• • • • • • • • • • • • • • • •.• • • • •• •• • • • • • • • • •.• • • • • ••• General Electrical Notes: • .•. • • • •.• • • • • • • • • • • • • • • • • • • • 1. All work shall be in accordance with the Florida Building; :dd, N.E.0 �Jr d a orsesponding:Municipality Codes 2. The contractor is responsible for evaluating field conditions by visting the site prior to commencing / bidding work. •• • • • •• ••• •• 3. The contractor shall satisfactorily repair / replace equipmerft,pr of stdicO r& damaged as a result of his work. Surfaces and • finished areas shall be restored to match adjacent areas. • •• • • • • • ••• •. 4. All material removed shall be disposed of as directed by owner. 5. All wiring indicating existing is based on original contract documents and is to be verified by contractor at job site. 6. All conductors shall be copper except as noted, all conductors shall be run in conduit. 7. All materials shall be U.L. approved. 8. New typewritten panel tally shall be furnished after job is completed reflecting all changes and additions. 9. All branch circuits shall be properly phase balanced. 10. Contractor shall seal all openings with a fire seal. 11. Fuses shall be dual element, time delat type unless otherwise noted. 12. Risers are diagrammatic only. They do not show every bend required for installation. 13. This drawing is a guide for installation of electrical service. The electrical contractor is responsible in providing a functional system. 14. All cables shall be run without splices except when otherwise noted. 15. All pull and junction boxes shall be accessible at all times. 16. Exact point and methods of connection shall be determined in field. 17. All work shall be done in a neat and workmanlike manner. 18. All underground conduit runs to have a minimum of 24" of cover. 19. all exterior electrical equipment shall be weather proof or shall be in a weather proof enclosure. 20. All trenching and backfilling shall be done by electrical contractor. 21. Conduit running under paving shall be 24" below finished grade as a minimum. 22. Coordinate all power utility work with local power company engineer. 23. The top elevation of the generator pad shall not be lower than the base flood elevation. Verify with survey and comply. 24. Generators and above -ground fuel tanks must be screened from public view by landscaping or other acceptable material. 25. Electrical Contractor shall verify all circuits in each panel. *y_ Commission # GG10971 Expires: May 30, 2021 a,' Bonded thru Aaron Notary LEMOS RESIDENCE - 601 GRAND CONCOURSE MASTER CONSULTING ENGINEERS, INC. 5523 WEST CYPRESS STREET SUITE 200 TAMPA, FLORIDA 33607 EB: 8426 JAMES R. MEHLTRETTER, P.E. FL # 33860 July 11, 2014 • ••. • • • ••• •• •• . • • •• •• • • • • • • • ••• • • •• • • • • ••• • •• •• • • • • • • • • • • ••• • • • • • ••• • ••• • • • ••• GENP1CD:-IUAR4CARE•Pi►DS FORGENERAC GENERATORS SOUTH 14.0:311§A (MIAMI• QADVBRO A 4RQ, PALM BEACH COUNTIES) • • • CLIENT: DIVERSITECH PROJECT: WIND ANALYSIS HURRICANE PADS MAX. WIND SPEED 175 MPH CODES: FLORID BI jILDJJVG CQDE 7I60 • • • • • ASCE 7-10 • • • • • • • • RISK O4TE • II • • • • • • MIAMI DbD IN �Y BISIQ WIND€PEED = 175 MPH BROMMRD SOIINTY 914SICINItt SPE& =190 MPH USE A BASIC WIND SPEED OF 175 MPH Kz- Kd= Kzt- Wind Speed V- qz= 0.00256'Kz'Kzl'Kd'V^2'I F= gz'G"CPAI (Eq. 6-28) G= 0.85 Cf= (Figure 6-21)ASCE 1.30 Wind Pressure F= Wind Pressure 'AI Af-LxH WIND SPEED 175.00 0.85 Exposure C ; Table 28.3-1 0.85 Table 26.6-1 1.00 Figure 26.8-1 175.00 56.57 62.51 PSF (4) 3/8" DIA 1 1/4" LONG ZINC COATED SET IN 4" SOLID CONCRETE PSF See Tables Pressure 62.51 PSF PULLOUT = 3899# ULT PER TEST (ASTM E-488-96 SEE NOTE 6) PULLOUT = 974# SERVICE (FS=4.0) INSTALL BOLTS THROUGH UNIT BASE PER MANUFACTURE'S SPECIFICATIONS GENPAD HURRICANE PAD 4" THICK MODEL# WEIGHT L W FG3154-4G 240 54 31 NOTES: 1 LOAD COMBINATION ASD PER 2.4.1 ASCE 7-10 0.6 x DEAD + 0.6 x WIND (ASCE 7-10; 2.4.1) 2 DESIGN IS BASED ON SECTION 29.5 OF ASCE 7-10 "OTHER STRUCTURES" UNITS ARE TO BE LOCATED ON THE GROUND. 3 ALL OTHER UNITS NOT SHOWN MUST BE DESIGNED ON A CASE BY CASE BASIS. 4 LARGER HURRICANE PAD USED IN SOME COMBINATIONS TO SATISFY DESIGN CHECK. 5 WINO PRESSURE ON UNITS IN ACCORDANCE WITH ASCE 7-10 FIGURE 29.5-1 6 ANCHOR TEST DATA BASED ON ARCHITECTURAL TESTING REPORT NUMBER 47207.01-106-31 DATED 03/04/2011. PAD .6(UNIT + PAD) MAXIMUM UNIT DIMENSIONS MINIMUM WEIGHT PAD WEIGHT WEIGHT .6xDEAD .6xWIND REMARKS W L H POUNDS MODEL # ASD DEAD LOAD MOMENT F ASD DESIGN WIND MOMENT SF DESIGN Allowable Pressure qz Allowable Wind Speed V NUMBER FT-# # FT-# OVERTURN CHECK PSF MPH MANUFACTURER MODEL GENERAC 8 kw 25.000 48.000 29.000 360 FG3154-4G 240 360 465.00 604.27 438.10 1.06 OK OK FOR 175 MPH 66.3 180 GENERAC 10 kw 25.000 48.000 29.000 407 FG3154-4G 240 388 501.43 604.27 438.10 1.14 OK OK FOR 175 MPH 71.5 187 GENERAC 14 kw 25.000 48.000 29.000 435 FG3154-4G 240 405 523.13 604.27 438.10 1.19 OK OK FOR 175 MPH 74.6 191 GENERAC 16 kw 25.000 48.000 29.000 448 F63154-40 240 413 533.20 604.27 438.10 1.22 OK OK FOR 175 MPH 76.1 193 GENERAC 16 kw 25.000 48.000 29.000 513 FG3154-46 240 452 583.58 604.27 438.10 1.33 OK OK FOR 175 MPH 83.3 202 GENERAC 17 kw 25.000 48.000 29.000 471 F53154-4G 240 427 551.03 604.27 438.10 1.26 OK OK FOR 175 MPH 78.6 196 GENERAC 17 kw 25.000 48.000 29.000 431 FG3154-4G 240 403 520.03 604.27 438.10 1.19 OK OK FOR 175 MPH 74.2 191 GENERAC 20 kw 25.000 48.000 29.000 516 FG3154-4G 240 454 585.90 604.27 438.10 1.34 OK OK FOR 175 MPH 83.6 202 GENERAC 22 kw 25.000 48.000 29.000 526 FG3154-40 240 460 593.65 604.27 438.10 1.36 OK OK FOR 175 MPH 84.7 204 53� 13p c, +".a FG3154-4G PAD 14DIA. SOLID CONCRETE @ BOLTS TYPICAL STRUCTURAL REVI APPROVE© LEMOS RESIDENCE - 601 GRAND CONCOURSE Page 1 of 1 S-1