Loading...
RF-18-2411Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address Issue Date: 9/12/20^18 Permit NO. RF-9-18-2411 Permit,fyype: Roof Work Classification: Metal Permit Status: APPROVED Expiration: 03/11/2019 Parcel Number Applicant 1301 NE 103 Street Miami Shores, FL 33138- 1132050300100 Block: Lot: ALFONSO DE ANDA LINA AMSH Owner Information Address Phone Cell ALFONSO DE ANDA LINA AMSHTA 1301 NE 103 Street MIAMI SHORES FL 33138- 1301 NE 103 Street MIAMI SHORES FL 33138- Contractor(s) Phone HURRICANE ROOFING OF FLORIDA II (954)483-7779 Cell Phone Valuation: Total Sq Feet: $ 37,000.00 4952 Type of Work: Re Roof Additional Info: RE -ROOF METAL & FLAT Classification: Residential Scanning: 3 Fees Due Bond Type - Contractors Bond CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $500.00 $22.20 $5.25 $3.50 $7.40 $350.00 $9.00 $29.60 $926.95 Pay Date Pay Type Invoice # RF-9-18-68837 09/12/2018 Check #: 1155 Bond #: 3887 Amt Paid Amt Due $ 926.95 $ 0.00 Available Inspections: Inspection Type: Tin Cap Final Roof Final Roof Cap Sheet Roof in Progress Renailing Affidavit Review Planning Review Roof In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. 7! Authorized Signature: Owner / giant / Contractor / Agent September 12, 2018 Date Building Department Copy September 12, 2018 1 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Ave, Miami Shores, Florida 33138 Tel: 305-795-2204 Fax: 305-756-8972 Inspection Number. INSP-001945-2018 Permit Number. RF-9-18-2411 Scheduled Inspection Date: November 29, 2018 Inspector Naranjo, Ismael Owner. ALFONSO DE ANDA LINA AMSHTA Address: 1301 NE 103 ST Project Miami Shores , FL 33138 Contractor. HURRICANE ROOFING OF FLORIDA INC EVGENIYA ALEXANDROVNA PAVLYUKOVA Permit Type: Roof Inspection Type: Roof Installation Work Classification: Metal Phone Number. Parcel Number 1132050300100 Phone Number. 9544837779 Building Department Comments RE -ROOF METAL & FLAT Checklist Item General Comments Passed False Comments Passed d Failed Correction Needed Re -Inspection Fee NoAdditional Inspections can be scheduled until re -Inspection fee is paid. Inspector Comments rimy( 1.1410), ot November 28, 2018 For Inspections please call: 30 -762-4949 Page 19 of 26 .6\ct-tAa-%\ -cot\►'7.`fi Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Honda 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION UNE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION El BUILDING ELECTRIC El ROOFING El PLUMBING ❑ MECHANICAL El PUBLIC WORKS Jos ADDRESS: 1301 NE 103 ST FBC 20 Master Permit No. I Tr- 18- 2411 Sub Permit No. ❑ REVISION ❑ EXTENSION ❑ RENEWAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS City: Miami Shores Folio/Parcel#:11-3205-030-0100 Occupancy Type: Load: County: Miami Dade Zia: 3 3 13S Is the Building Historically Designated: Yes NO X Construction Type: Flood Zone: BFE: OWNER: Name (Fee Simple Titleholder): LINA AMSHTA Address: 1301 NE 103 ST FFE: Phone#: city: MIAMI SHORES State: FL Zip: 33138 Tenant/Lessee Name:.. Phone#: 786.346.2966 Email: ROOF i > 31r o F- -Ft 0c2 A w^ , CONTRACTOR: Company Name: HURRICANE Phone#: 954.483.7779 Address :L 1301 NE 103-ST" City:MIAMI SHORES State: FL zip: 33138 Qualifier Name: T-\11'Qrn'i..( ct Po""l I(ju 2C)Nt ___ Phone#: ctS LI4 8 37`179 State Certification or Regration #: CCC1330213 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address:. City: State: 4 Zip: Value of Work for this Permit: .$ 3C7, O0 ..4' '' Square/Unear Footage of Work: q S 2- s Type of Work: ❑ Addition ❑ Alteration ❑ New Description of work: RE -ROOF 1,Aet J d F I c T Repair/Replace ❑ Demolition Specify color of color thru tile: -e_ c,R 21 Submittal Fee $ Permit Fee $ a s 0 cas 2 Z . 2-(.) co/cc $ p Scanning Fee $ i Radon Fee $ 3 , 5 d DBPR f h 5 • ZS Notary $ Technology Fee $ a • 6 —7 b Training/Education Fee $ L • 'tV Double Fee $ e0 Structural Reviews $ "'�1` Bond $ SO O . ° _, P, TOTAL FEE NOW DUE $ 42,‘ • aI (N (Revtsed02/24/2014) Bonding,Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. 1 understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR1NOTICE OF COMMENCEMENT." Notice to Applicont: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit Is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT The foregoing instrument was acknowledged before me this 2� day of 11--1--y' ,20 /e ,by S/'c—, who is personally known to me or who has produced D( 52 3- 5-3 :76--67a -Q identification and who did take an oath: NOTARY PUBUC: Sign: Print: Seal: Notary Public State of Florida Jessica Rivera My Commission GG 223853 0,001, Expires 05/31/2022 APPROVED BY Signature CONTRACTOR The foregoing instrument was acknowledged before me this `2 day of , 20 iS , by O P h,�� �a� �.t u l(�✓ who is personally known to ✓ me or who has producedas identification and, who did take an oath. NOTARY PUBLIC: Sign: Prin Qom►--z-1 CAP C L �P_vietce CAMI.Amc_ ' Seal VENEICE CAMMOCK p: : MY COMMISSION # GG 090702 EXPIRES: April 15, 2021 `,Rtrg.;'' Bonded Thru Notary Public Underwlters **s**************is**ss**IihrbsePif • swiPWWItIC * *******s*s*** Plans Examiner Zoning Structural Review Clerk (Revisedo2/24/2014) Property Search Application - Miami -Dade County 4 OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-3205-030-0100 Property Address: 1301 NE 103 ST Miami Shores, FL 33138-2623 Owner ALFONSO DE ANDA LINA M AMSHTA Mailing Address 1301 NE 103 STREET MIAMI SHORES, FL 33138 USA PA Primary Zone 1100 SGL FAMILY - 2301-2500 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds/Baths/Half 4/4/0 Floors 1 Living Units 1 Actual Area 3,963 Sq.Ft Living Area 3,167 Sq.Ft Adjusted Area 3,383 Sq.Ft Lot Size 10,350 Sq.Ft Year Built 1963 Assessment Information Year 2018 2017 2016 Land Value $372,579 $372,579 $347,118 Building Value $287,555 $312,843 $315,126 XF Value $2,151 $2,162 $2,173 Market Value $662,285 $687,584 $664,417 Assessed Value $545,710 $534,486 $523,493 Benefits Information Benefit Type 2018 2017 2016 Save Our Homes Cap Assessment Reduction $116,575 $153,098 $140,924 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description REPLAT OF TR B MIAMI SHORES BAY PARK ESTS PB 63-17 LOT 1 BLK 6 LOT SIZE 90.000 X 115 OR 17568-0805 0197 4 Page 1 of 1 Generated On : 7/25/2018 Taxable Value Information 2018 2017 2016 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $495,710 $484,486 $473,493 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value $520,710 $509,486 $498,493 City Exemption Value $50,000 $50,000 $50,000 Taxable Value $495,710 $484,486 $473,493 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value $495,710 $484,486 $473,493 Sales Information Previous Sale Price OR Book- Page Qualification Description 0429/2011 $700,000 27690 4108 Qual by exam of deed 01/01/1997 $0 17568- 0805 Sales which are disqualified as a result of examination of the deed 05/01/1993 $195,000 15614 Sales which are qualified 06/01/1989 $194,500 14531- 1741 Sales which are qualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disdaimer.asp Varese https://www.miamidade.gov/propertysearch/ 7/25/2018 • Miami Shores Vivage Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: Li N A to M S-1 T A Property Address: t �v o f NE" l 0 3 57. Date: Roofing Permit Number: Dear Building Official: I Mt AHAtscertify that I am not required to retrofit the roof to wall connections of my building because: The just valuation for the structure for purpose of ad valorem taxation is less than•$300,000.00. Please attach proof of ad valorem taxation. • o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 e ition of the South Florida Building Code (1994 SFBC) polo Signature r1/9 ANAS.t Print Name State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he/she is the owner for the Swom to and subscribed before me this S day of �w Notary Public, Sate of Florida at La ye property mentioned. Notary Public State of Florida Jessica Rivera My Commission GG 223853 Expires 05/31/2022 • When the Just valuation of the structure for purpose of ad vWloren taxation is equal to or more than S300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a buiding application from a Genial Contractor forte Roof to Wall connection Hurricane Milpation. Revised on 5/21/2009 kFcall Business Tax eceipt Miami -Dade County, State o Florida -THIS IS NOT A BILL - DO NOT PAY 7206987 BUSINESS NAME/LOCATION HURRICANE ROOFING OF FLORIDA INC 3438 W 84TH ST UNIT 1 1 1 HIALEAH FL 33018 OWNER HURRICANE ROOFING OF FLORIDA INC EVGENIYA PAVLYUKOVA Worker(s) 1 RECEIPT NO. RENEWAL 7490236 J EXPIRES SEPTEMBER 30, 201'9 Must be displayed at place of business Pursuant to County Code Chapter BA - Art. 9&10 SEC. TYPE OF BUSINESS 196 SPECIALTY BUILDING CONTRACTOR PAYMENT RECEIVED CCC1330213 SY TAX&CPLLECTOR- $45.00 08Y30/2018 CREDIN4 -.18 . 562 4 This Local Business Tax Receipt only confirms payment of the Local Business Tax. The Recetp�cn,= permit, or a certificationof the holder s ualificatio s, to do business.. Holder must comply - or nongovernniental regulatory laws and requirements which apply to the Justness. r ?- The RECEIPT NO. above � ,,, J { � must be displayed anal! commercial tees t# -.F�t! Forimore information; visit ro id ,gg f e r Act) Ref CERTIFICATE OF LIABILITY INSURANCE ' DATE (MM/D0fYYYY) 9/5/2018 • THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS • CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES • •BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN. THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(les) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on • . this certificate does net confer rights to the certificate holder in lieu of such endorsernent(s). PRODUCER Presidential Insurance Services, Inc. 2665 South Bayshore Drive #707 Miami, FL. 33133• •INSURER CONTACT Jeff Lampert NAME: PHONE MIC 14411131; 305-423-0350 ••1 rkuc, No), 305-423-0351 glatigss• jeff@insurancequotelive.com INSURER(S) AFFORDING COVERAGE NAIC A: Preferred Contractors Insurance Company INSURED Hurricane Roofing of Florida,Inc. 3438 W. 84th Street Bay 111 • Hialeah, FL..33018 INSURER B : INSURER C : INSURER D : INSURER E • INSURER F : COVERAGES: CERTIFICATE NUMBER: • THIS,IS TO CERTIFY -THAT THE POLICIES OF. INSURANCE LISTED BELOW HAVE BEEN'ISSUED TO THE INSURED NAMED ABOVE .FOR THE POLICY PERIOD. INDICATED. NOTWITHSTANDINGANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY. BE ISSUED OR MAY PERTAIN; THE INSURANCE AFFORDED BY THE POLICIES. DESCRIBED HEREIN • IS -SUBJECT .TO ALL THE • TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES,LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. • . INSR LTR ,- TYPE OF INSURANCE ADDL INSD SIM WV!) , ' • POLICY NUMBER • POLICY EFF - (MM/DDIYYYY) POLICY EXP (MWDDIYYYY) LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE ' 1 $ •. 1,000,000 CLAIMS -MADE X OCCUR • DAMAGE TO RENTED PREMISES fEa occurrence) $ 50,000 LIED EXP Any one person) S 5,000 • PC-88670-06 5/28/2018 5128/2019 PERSONAL & ADV 'INJURY •• 1,000.000 GEN'L AGGREGATE LIMIT APPLIES PER: •GENERAL AGGREGATE . - $ 2,000.000 X POLICY : L j LOC . • PRODUCTS • COMP/OP AGG $. 1,000,000 OTHER: • $ • AUTOMOBILE LIABILITY •(Ea COMBINED SINGLE LIMIT accidert) ANYAUTO . • BODILY INJURY (Per person) 3 OWNED AUTOS ONLY - SCHEDULED AUTOS BODILY INJURY ;Per neddenn $ HIRED • NON -OWNED AUTOS ONLY • • . PROPERTY DAMAGE . (Per e...10Lentl 1• $ $• UMBRELLALIAB• I OCCUR —; EACH OCCURRENCE $ • EXCESS LIAB • , I ciAlms_mA6E 1 AGGREGATE • DED I -I RETENTIONS •• $ • • WORKERS COMPENSATION . . AND EMPLOYERS' LIABILITY . - . : I PER 1 24"- • ANYPROPRIETOR/PARTNER/E.'XECUTIVE OFFICEFUMEMBER EXCLUDED? y IN N/A E.L. EACH ACCIDENT 3 • (Mandatory In Nil) • • if describe • E.L. DISEASE - EA EMPLOYEE $ yes, under DESCRIPTION OF OPERATIONS below E.L. DISEASE - POLICY LIMIT $ • . • DESCRIPTION OF OPERATIONS i LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required) . . • . . License# QCC1330213 • ....,, ..• .. . • CERTIFICATE HOLDER CANCELLATION • Village of Miami Shores . 10050 NE 2nd Ave. • Miami Shores, FL. 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION 'DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. •- • • AUTHO PRESENTATIVE 4 © 198 .2015 ACORD CORPORATION. All rights reserved. ACORD 26 (2016/03) The ACORD name and logo are register emarks of ACORD CERTIFICATE OF LIABILITY INSURANCE Date I 8/29/2018 Producer: Plymouth Insurance Agency 2739 U.S. Highway 19 N. Holiday, FL 34691 (727) 938-5562 This Certificate Is Issued as a matter of Information only and confers no rights upon the Certificate Holder. This Certificate does not amend, extend or alter the coverage afforded by the policies below. Insurers Affording Coverage NAIC # Insured: South East Personnel Leasing, Inc. & Subsidiaries 2739 U.S. Highway 19 N. Holiday, FL 34691 Insurer A: Lion Insurance Company 11075 Insurer B: Insurer C: Insurer D: Insurer E: Coverages The policies of insurance listed below have been issued to the insured named above for the policy penod indicated Notwithstanding any requirement term or condition of any contract or other document with respect to which this certificate may be issued or may pertain, the insurance afforded by the policies described herein is subject to all the terms, exclusions, and conditions of such policies. Aggregate limits shown may have been reduced by paid claims INSR LTR ADDL INSRD Type of Insurance Policy Number Policy Effective Date (MM/DD/YY) Policy Expiration Date (MM/DD/YY) Limits GENERAL LIABILITY Commercial General Liability Each Occurrence $ Darnage to rented premises (EA occurrence) Claims Made Occur Med Exp $ , General D Personal Adv Injury i. aggregate limit applies per: General Aggregate Policy ❑ Project ❑ LOC Products - Comp/Op Agg $ AUTOMOBILE LIABILITY Any Auto All Owned Autos Scheduled Autos Hired Autos Non -Owned Autos Combined Single Limit (EA Accident) $ e Bodily Injury (Per Person) $ Bodily Injury (Per Accident) $ v Property Damage (Per Accident) $ EXCESS/UMBRELLA LIABILITY Occur ❑ Claims Made Deductible Each Occurrence Aggregate A Workers Compensation and Employers' Liability Any proprietor/partner/executive officer/member excluded? NO If Yes, describe under special provisions below. WC 71949 01/01/2018 01/01/2019 X I WC Statu- tory Limits I OTH- ER E.L. Each Accident $1,000,000 E.L. Disease- Ea Employee $1,000,000 E.L. Disease- Policy Limits $1,000,000 Other Lion Insurance Company is A.M. Best Company rated A (Excellent). AMB # 12616 Descriptions of Operations/Locatlons/Vehicles/Excluslons added by Endorsement/Special Provisions: Client ID: 92-70-730 Coverage only applies to active employee(s) of South East Personnel Leasing, Inc. & Subsidiaries that are leased to the following "Client Company": Hurricane Roofing of Florida, Inc Coverage only applies to injuries incurred by South East Personnel Leasing, Inc. & Subsidiaries active employee(s), while working in: FL. Coverage does not apply to statutory employee(s) or independent contractor(s) of the Client Company or any other entity. A list of the active employee(s) leased to the Client Company can be obtained by faxing a request to (727) 937-2138 or by calling (727) 938-5562. Project Name: ISSUE 08-29-18 (KLR) Begin Date: 6/14/ 2018 CERTIFICATE HOLDER CANCELLATION VILLAGE OF MIAMI SHORES 10050 NE 2ND AVENUE MIAMI SHORES, FL 33138 Should any of the above described policies be cancelled before the expiration date thereof, the issuing insurer will endeavor to mail 30 days written notice to the certificate holder named to the left, but failure to do so shall impose no obligation or liability of any kind upon the insurer, its agents or representatives e v' r' f---. -- RICK SCOTT, GOVERNOR JONATHAN ZACHEM, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESSAND PROFESSIONAL REGULATION CONSTRUCTIOQN NDUSTRY=INCENSING BOARD 4 THE ROOFING CONTRACTORWHEREIN IS'CERTIFIEDUNDER THE PROVISIONS OF4CHARTER489 FLORIDANSTATUTES MfO. _.s ' PAVLYUK11_.f:._... ilk -141.i �.r =HURRICANE"RO FINE/OFF C RIDA IP �' P+4�p38tfN1&}Wyk-84TH ST��yUyNIT' 1i11 1/4 H IAL EAH F11, 33018 ley- 's, LICENSENNUMBERCC�C1r330213 +�c..s ...s RYa, ..sir EXPI RATION DATE` AUGUST 31, 2020 Always verify licenses online at MyFloridaLicense.com Do not alter this document in any form. DROVNA This is your license. It is unlawful for anyone other than the licensee to use this document. t. • ,a 01% Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Section A (General information) Master Permit No. Process No. Contractor's Name HURRICANE ROOFI Job Address 1301 NE 103 ST MIAMI S ROOF CATEGORY ® Low Slope 0 Mechanically Fastened Tile 0 Mortar/Adhesive Set Tile A s pha l ti c El Metal Metal Panel/Shingles 0 Wood Shinglesl8h Shingles re •••••• •••• A►re ❑ Prescriptive BUR-RAS 150 Gas Vhnnt $tackf. • •. • YYAa•1doS •••• ••••� ROOF TYPE Type: Nd Ltt dlU LPG)CC] :..., • • 0 New Roof CB Re -Roofing 0 Recovering 0 Repair 'D MaintOhance • . ROOF SYSTEM INFORMATION .. .. • .. • . . .••. Low Slope Roof Area (SF) Steep. Sloped Roof Area (SF) Total (eF) •• • 486SF 4466SF 4952SF • • • • • • Section B (Roof Plan) Sketch Roof Plan: illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include. dimensions of sections and level% dearly Identify dimensions of elevated pressure :ones and location of parapets. C■" ■■misammosamasom empansanssmCsananammsammmCCi■■■■CCC" =E mE■rows■C■Cw//■w■wwwwswwwwwm■ww■/w■w■■w■pommamm a■Maps amw■■■■ mmwmas%CCC:"mmamosCCCCCpa ummasiCaC Nammo mamma C IMENNEs CmCmmmsommm'�CmECECECnCCmaamaipapaswCCwa"■ECCCmCmaa Ts11 wall m m CwsmCaaw"CCCaammaaw"mCCE/sEwmm """"C E" "C" rww w ■wpw/C■Iwwwww/■■s "" CCma"/"aawsE m/m� w ■■/wmppw w/w ar ilmammas CCNaismaman EEamCC:■EEM:IN■:::B :NEEE:EC:E:mma"� ■■.ow..r ■■prop ■ �/C■/m■ mw m m■■//■■ p E C C C =E "ammamsmaaam"/■■m■■/Cam ■Cal■w■ w■p/ ■E/■ ■Ew�p rip: ■rowi 1111111s1.11.u'Cmm�Cam aC "a""m"ma/Cams""a" GC� :III Cm pro ■ __ m-: -SEE ATTACHED El a rr ///■■///■w/ w/ EC lameihearciippyirinuppuliplaNk C" moms C mm■a platy�' C■w■rO■■■■CwwwC■aawaw■m�pam■E■Eswam NCPil mE ri w ■. w .R. * ....G■ . G■w■www m w■w m■ MINI ■ma mom ■Isms row warp/ ■ _rowCCmCCCCai"ram"Cam""wCaCCw/"mmCaCmC :ma�i""row C"E w.' Y rpm Iw ■■w • a"UEsamaamaaam"Caaa "mImm` EE EE E s'r -- C---ii.ai.aiu:i.wi/ //p p■//Cmwa/w■p/m/ ///■/ml""C4m 1a — " C"a mC"a■Ca""m CCCEC CCC""CCCCm .i Cam:: "" ■ ■C FA s:■w*uusir.C"Caa CCmmEm CC" " mm "l a" "a _ _ _..-, Cial /C• i ■/C" w aG"■a"■ row■ w .m C Cu■"■a.. a"l ■■_ WIWI FIR " HIP "if-mw_ ■G CE /IlammammHalm■ - - ■■ ■wCCGCCCCMC■■ mid / GiwaCim irrapaprN ■ -`�- • ....4 00 0® roofcrders.corri ROOF PLANS FROM AERIAL IMAGERY . Edge Length Summary -;Edge•Type : h-grth"(Et4 °,. Eave 417.70 Rake 12.00 "lip 150.80 Valley 62.70 Ride 129.50 StepFlashing 9.60 ApronFlashing 16.90 Roof Area Summary Pitch Area 0 (Sq. Ft: e- 0/12 486 5/12 4466 Total 4952 Page #4: Edge Length ti 28.2 CO 28.2 t) A 1301 NE 103rd St Miami Shores FL 33138 OSA w 29.5 rim MIM. to. 0) 29.5 47.2 20.0 •• ••• • • • • . .. • • • • . •• N •• •• • • • •• O O • • •r• • • • • • • �•• ▪ •• •• • • • • �••• • • • • • • • • • 006 • • • • • • • • • • • • • 000 • 0 • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • 21.3 Note: Labels for Edge(s) less than 5 feet and Face(s) less than 25 square feet are not displayed for better readability. e SECTION 1524 HIGH VELOCITY HURRICANE ZONES -REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS • • • '•••• 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor i'o'provide thi owliir with • the required roofing permit, and to explain to the owner the content of the section. The" • •' of • • in R 4402 govern the minimum requirements and standards of the industryfor roofing system ins R'� 9 ys tailagpns. Addition*, the following items should be addressed as part of the agreement' between the owner ant tlaccirftractor; TM burner's initial in the designated space indicates .that the item has-been explained. 6. • . .... . Renalling wood decks: When replacing roofing, the existing rid if GIY Dave to be in accordance with the current provisions of Section R4403. (TherotQedc is dually • concealed prior to removing the existing roof system).• • • • • • •• • Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be •acceptable. This provides the option of maintaining the appearance. Overfeow scuppers (waft outlets): ft is required that rainwater flows off so that the roof is n . ' overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R44t'and R4413. D774c4 13o t Noe. to-3 T. Property Address Revised on 7/9/2009 LD;07/01/2015; -7h9,2te Contractor Signature Date Permit Number Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERM1.F. APPLICATION FORM AND ATTACH THE: REQUIRED DOCUMENTS AS NOTED BELOW: • • . . .... • ... • . • .. •. . •... • . . • Roof System Required Sections of the Permit Application Form Attachment6fttiquirpi..: See List BiidW • 1,2,3,4,5,6jji' :' ' • Low Slope Application A,B,C Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 ' • •' : .. •• . Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1.2.3.4.5,6,7 Metal Roofs A,B,D 1,2,3,4,5,6,7 Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Notice of Acceptance: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS 126 4. Other Component Notice of Acceptances 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Re -Roofing Only) 7. Any Required Roof Testing/Calculation Documentation ••• ••• • ••• • ••• • ••• ••• .• • ••• Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Slopej! Roof System) Fill in Specific Roof Assembly Components and identify Manufacturer (If a component is not used, identify as "NA-) System Manufacturer, GAF NOA No.: 14-1030.01 Design Wind Pressures, From RAS 128 or Calculations: Pmax1: -42.8 Prn x2: -71.7 Pmax3: -108.Q Max Design Prevsyae, From the Specific NOA System: -52.5 Decic Type- PLYWOOD Gauge/Thickness: 5/8 Slope: 1/4:12 Anchor/Base Sheet & No. of Ply(s): N/A Ancho NBes Sheet Fastener/Bonding Material: Insulation Base Layer. N/A Base insulation Size and Thickness: N/A Base Insulation/AastenetBonding Material: Top Insulation Layer: N/A Top Insulation Size and Thldcness: N/A Top Insulation Fastener/Bonding Material: N/A Base Sheet(s) s No. of Pty(s): #75 1 PLY Base Sheet Fastener/Bonding Material: 1.25" R.S. NAILS AND TIN t^.APS Fastener Spacing for AnchorlBase Sheet Attachment Field: oc @ Lap. # Rows ? ®_ 9• oc Perimeter:12 oc @ Lap, # Rows A_ ,_." oc Comer: .• oc to Lap, # Rows 4 @ _f22 oc Number of Fasteners Per Insulation • , , , , • • . . ..• . . .. • Field N/A Perimeter N/A oorwsr.. •N/A , Illustrate Components Noted and . Details as Applicable: • Woodblocktng, Gutter, Edge • *Termination, Strapping, Flashing, Continuous' •G�eet, Cant . Strip, Base Flashing, Counter- •Flashing, • Coping, Etc. • Wink: Mean Roof Height, Pass* >leight„ Height of Base Flashing, Component Matertdl, , • • • Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. Board Ply Sheet(s)4 No. of Ply(s): PLY 4, 2 PLY Ply Sheet Fastener/Bonding Material: APPROVED A$PHAI T Toppty: MINERAL SURFACED CAPSHEET Top Ply FPtenor/ Bonding Material: PROVED SPHALT Surfacing: N/A P Aerax.k -34 Zb6 "r 1 Y 7 1 Tt t 5/8" PLYWOOD SI Plis. it. -is-iw ecLpreci us, iyy°'R-S.> s pG.es o P i J o"c koopeci FT. Fr. N/A Parapet Height 9' Mean Roof Height Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section D (Steen Sloped Roof System) Roof -System Manufacturer: DREXEL METALS INC. Notice of AcceptanceNumber: 18-0807.01 • • • • . . • . • • • • • ••.. Minimum Design Wind Pressures, 11 Applicable (From RAS 12T•ei Calculations): P1: -9.1 P2: -68.1 P3: -inn 7 •••• • -..... • • •• •• 1• Maximum Design Pressure . (From the NOA Specific System): -106.75 PSF •• • •• • • ••.�.. Method of tile attachment: (2) #10 PANCAKE HEAD FASTEN.ERS'SPAOENkT 12" O.C. IN FIELD AND 6" O.C. IN PERIMETER AND CORNER ••• Roof Slope: 5 :12 Steep Sloped Roof System Description Deck Type: . ....• . •..•: •••.• • • • 5/8" PLYWOOD ype Underlayment: nsulatlon- Ridge Ventilation? N/A ASTM 226 TYPE II #30 1 PLY N/A 13 rner. VERSASHIELD astenerType & Spacing: 1.25" R.S. NAILS AND TIN CAPS 12" O.C. FIELDS 6" O.C. CO LAPS dhesive Type: Mean Roof Height: 12. N/A ype Cap Sheet. N/A oof Covering: DMC 150SS .032" ALUMINUM 16" WIDE PANEL Type & Size Drip dge: 3X3.40 ALUMINUM DRIP . • • MIAMID COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) GAF 1 Campus Drive Parsippany, NJ 07054 MIA14II-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315.2590 F (786) 31525.99 www.miamidade.eov/economy •••• • • • • • • • • •• • SCOPE: •. This NOA is being issued under the applicable rules and regulations governing the use of seustructioti • • . materials. The documentation submitted has been reviewed and accepted by Miami -Dade County REt - • Product Control Section to be used in Miami Dade County and other areas where allowed4rti Autlprrty: • ' Having Jurisdiction (AHJ). • . • • • This NOA shall not be valid after the expiration date stated below. The Miami Dade. County Pt'bduct • Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami DaJe County) ' • • reserve the right to have this product or material tested for quality assurance purposes. If this product•or •. material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built -Up Roof Systems for Wood Decks. • •• • .• • • • • • • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 13-1022.15 and consists of pages 1 through 31. The submitted documentation was reviewed by Jorge L. Acebo. I.APPROVED NOA No.: 14-1030.01 apiration Date: 11/04/18 pproval Date: 05/04/17 Page 1 of 31 Membrane Type: BUR Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank decks secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type E(1): Anchor sheet mechanically attached to roof deck. . . All General and System Limitations shall apply. •• . `. • • • • •. . . .. . Fire Barrier: (optional) Base sheet: Fastening Option #2: Maximum Design Pressure: Topcoat® FireOut"" Fire Barrier Coating, VersaShield® Fire Resis'tii.M ft ,of Deck"' • Protection, VersaShield® Solo" Fire -Resistant Slip Sheet installeil:�er!manufactucer'sli • installation instructions. • • GAFGLAS° #80 Ultima"' Base Sheet, Stratavent® Nailable Venth e Sheet,.Ri3.beroid®" "• M 20 Smooth, Ruberoid® SBS Heat -Weld"' Smooth or Ruberoid® SYS Mat -weir 25 base . sheet mechanically fastened to deck as described below; • • • • ' • • GAFGLAS® Flex Ply"' 6, GAFGLAS® #75 Base Sheet, Tri-Ply®;#7543ase Sheet or any of the above anchor sheets attached to deck with approved annular ring shank naifsagd'tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure 52.5 psi. See General Limitation #7) GAFGLAS® #80 Ultima"' Base Sheet, Ruberoid®20 Smooth or Ruberoid® Mop Smooth attached to deck with approved 11/4" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. (Maximum Design Pressure --60 psi: See General Limitation #7) Ply Sheet: One or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4 or GAFGLAS® #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfac Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or AFGLAS nergyCap'wMineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 galisq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. See Fastening Options NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 25 of 31 . • WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® Flex Ply' 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 'A" DensDeck" Roof Board or %" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: .. • 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Matcr.aals:Directo'rjrhbr fire • • • • • • ratings of this product. ...... • 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliand.with Produpt Control" Approval guidelines. All other layers shall be adhered in a fullmopping of approved aspl akepplied.within the ; • • • • EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattt to of the1411/er .. , .. 3. All standard panel sizes are acceptable for mechanical attachment. When applied in ap fd �lIasphaat. pplel size..:..' shall be 4' x 4' maximum. • .. • . . 4. An overlay and/or recovery board insulation panel is required on all applications over dosed cell foam insulations • when the base sheet is fully mopped. If no recovery board is used the base sheet shall be appjied usi ig €pot • .. • • • mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribboaa to {free royvrs, pne at ..... each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircfl ig't 'the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbsisq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (Le. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation N7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE r.i •,.��! 7 I ''.ail ^APPRCV'ED NOA No.:14-1030.01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 31 of 31 TGFU.R1306 - Roofing Systems Page 2 of 46 Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, 8 or C systems listed over C-15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does.not adversely affect the rating. The use of 1/2-In. minimum thick gypsum board is an acceptable alternate for minimum insulation over C-15/32 thick roof decks. The use of polystyrene Insulation board between minimum 3/4-In. thick periite board and deck with rosin paper (perlite/rosln paper/polystyrene/perlite) is a suitable alternate for polyisocyanurate board In the following Class A, B or C systems. Trumbull "Perms Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". "GAFGLAS® #80 Ultima"Base Sheet" may be used In any of the following systems. "GAFTEMP Permallte Recover Board" may be used in lieu of any partite insulation In any of the following NC Classifications. Unless otherwise Indicated, any of the °Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "United Coatings*" FireShleld MB Roof Coating" applied at a rate of 2-1/2 to 3-gal/100-ft2. • . • • • • • • Class A, B and C • • • •• • • •• Hot roofing asphalt, for use with glass felts or modified bitumen membranes. ... • • ' • • . •••• "RUBEROID® Heat Weld" SBS roofing membranes may be used in lieu of "RUBEROID® Mop" SBS roofing membranes in VW applicable • Classification. .... . . •• ••••.. Class A •••• • •••• •••••• _ • 1. Deck: C-15/32 Incline: 3 • ' •• - - - - - •• •• • Barrier Board (Optional): — One or more layers Georgle-Pacltk " �t es • Roofboard" or "DensDeck® DuraGuard"" Roofboard", minimum 1/4- n, . thick, or United States sRGypsum or. ECUROC ® Roof • Gypsum Co."SECUROCK® ReOf • Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX), minimum 1/4-In. thick. • • • • • • • • Insulation: — One or more layers perilte or wood fiber or glass fiber or polyisocyanurate or urethane or pMrjlWpotflsocyanurate • composite or perlite/urethane composite or wood fiber/potylsocyanurate composite or phenolic, any thickness. • • • Ply Sheet: — Three or more piles Type G1 "GAFGLAS® Ply 4" or " II -Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultwarnlexible Ply 6", fully adhered with hoot roofing asphalt. Surfacing: — Gravel. 2. Deck: C-15/32 Incline: 2 Barrier Board (Optional): — One or more layers Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuard'" Roofboard", minimum 1/4-in. thick, or United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX), minimum 1/4-in. thick. Insulation: — One or more layers petilte or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyenurate composite or perllte/urethene composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Ply Sheet: — Three or more plies Type G1 "GAFGLAS® Ply 4" or 'TM -Ply® PIy 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible PIy 6", fully adhered with hot roofing asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or'Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCap*" Mineral -Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 3. Deck: NC Incline: 2 Barrier Board (Optional): — One or more layers Georgia-Pacific Gypsum LLC "DensDeck® Roofboard" or "DensDeck® Prime Roofboard" or "DensDeck® DuraGuard'" Roofboard", minimum 1/4-in. thick, or United States Gypsum Co. "SECUROCK® Roof Board" (Type FRX-G) or "SECUROCK® Glass -Mat Roof Board" (Type SGMRX), minimum 1/4-In. thick. Insulation (Optional): — One or more layers petite or wood fiber or glass fiber or polyisocyanurate or urethane or periite/polyisocyanurate composite or periite/urethene composite or wood fiber/polylsocyanurate composite or phenolic, 2-in. maximum. Ply Sheets — Two or more plies Type G1 "GAFGLAS® Ply 4" or "Tri-Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6", fully adhered with hot roofing asphalt. Cap Sheet — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or "Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCap," O4.u Mineral-Surfaced Cap Sheet", fully adhered with hot rooting asphalt. C-15/32 Inclne:1 Slip Sheet G I): — Red rosin paper, nailed to deck. Insulation : — Any thickness peritte or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified Insulation adhesive. Base Sheet:. — One ply G2 "GAFGLAS® #75 Base Sheet" or'Tri-Ply® #75 Base Sheet" or "GAFGLAS® #80 Ultima*" Base Sheet" or "GAFGLAS® en a e en n chankally fastened. Ply Sheet: — One or more Mies Type G1 "GAFGLAS® PIy 4" or 'TA -Ply® Ply 4" or GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6", fully adhered with hot roang asphalt. Cap Sheet: — Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or'Tri-Ply® BUR Granule Cap Sheet" or "GAFGLAS® EnergyCap"" Mineral -Surfaced Cap Sheet", fully aonerea with hot roofing asphalt. Coating (Optional): — "United Coatings"' TOPCOAT® EnergyCote'M Roof Coating" or "TOPCOAT® MB Plus Coating" or "United Coatings' 000f M'a�e MB Plus Coating" applied at a rate of 2-gal./100-ft.2. 5. Deck: NC Incline: 3 Base Sheets — One ply Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Ply® #75 Base Sheet" or "GAFGLAS® #B0 Ultima"' Base Sheet" or "GAFGLAS® Stratavent® Nellable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet" or "GAFGLAS® Stretavent® Nailable Venting Base Sheet" or "GAFGLAS® Stratavent® Perforated Venting Base Sheet", mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet: — One or more plies Type G1 "GAFGLAS® Ply 4" or 'TM -Ply® Ply 4" or "GAFGLAS® Flex Ply 6" or "Tri-Ply® Ultra -Flexible Ply 6", fully adhered with hot roofing asphalt. •••••• 1 • •••••• • • ••••.• • • •••• • • ••••. •••••• • • OOOOO• • • •••••• • • http://database.ul.com/cgi-bin/XY V/template/LISEXT/ 1 FRAME/showpage.html7name=T... 5/24/2017 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) GAF 1 Campus Drive Parsippany, NJ 07054 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 www.mlamidade.eov/economv •... •. • • • • .... •..... . •. • o. . . This NOA is being issued under the applicable rules and regulations governing the use of cgri i ion materials. The• ........ • documentation submitted has been reviewed and accepted by Miami Dade County RER -Prods t•Control Secfion to be � •..: used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction 4 HJ). : ... • • • • This NOA shall not be valid after the expiration date stated below. The Miami -Dade County dtict C&ntwl.'Sectioit • : • • (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve 4be right to have this •' • • • product or material tested for quality assurance purposes. If this product or material fails t i p&rfbrm the accepted . manner, the manufacturer will incur the expense of such testing and the AHJ may immelliately. revo 'Modify, c suspend the use of such product or material within their jurisdiction. RER reserves the right ttt revoke this acceptanc4,• • • •: if it is determined by Miami -Dade County Product Control Section that this product or material faits• IS meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. SCOPE: DESCRIPTION: VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® Solon! Fire -Resistant Slip Sheet LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 14-1022.26 and consists of pages 1 through 3. The submitted documentation was reviewed by Alex Tigers. MIAMI. DE NOA No.: 16-1216.02 Expiration Date: 02/07/22 Approval Date: 02/02/17 Page 1 of 3 ROOFING ASSEMBLY APPROVAL Category: Sub -Category: Material: Roofing Underlayment Fiberglass SCOPE: This acceptance is for VersaShield® Fire -Resistant Roof Deck Protection (a.k.a "VersaShield® Underlayment") and VersaShield® Soloist Fire -Resistant Slip Sheet (a.k.a "VersaShield SoloTM"), as described in this Notice of Atttplance, for use with approved prepared roof assemblies. Designed to comply with the Florida Building bode and'iht High • Velocity Hurricane Zone of the Florida Building Code. PRODUCT DESCRIPTION: Manufactured by Agulicant VersaShield® Fire - Resistant Roof Deck Protection Dimensions 42" x 100' rolls VersaShield® Solon' 72" x 166.7' rolls Fire -Resistant Slip Sheet 36, x 166.7' rolls MANUFACTURING LOCATION: 1. Conover, NC EVIDENCE SUBMITTED: Test Agency PRI Construction Materials Technologies Underwriters Laboratories Inc. INSTALLATION: Test Sneci ications ASTM D 226 Type 11 ..... . OOOOOO . . • •... . . OOOOOO Prodder •: :.... pescaftidd - Non -Asphaltic fiberglass-8aseti ihiderliiytnegt and/or fire barrier. • ...... •.. • .. . • .. • . . .. . UL790 Non -Asphaltic fiberglass -based slip sheet and/or fire barrier. Test Identifier GAF-270-02-02 GAF-748-02-01 ELK-063-02-01 99NK45831 10NK11990 R19254 08CA37926 08CA49140 Test Name/Report ASTM D 226 ASTM D 226 TAS 100 UL790 UL790 ASTM D 226 UL790 Rite 11/15/10 12/12/16 09/27/01 03/21/00 05/18/11 09/13/01 09/23/09 1. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® So1oTM Fire -Resistant Slip Sheet shall be installed in strict compliance with applicable Building Code. 2. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® Solo TM Fire -Resistant Slip Sheet shall be installed with a minimum 4-inch head lap in a shingle layer fashion. 3. VersaShield® Fire -Resistant Roof Deck Protection shall be mechanically fastened with approved fasteners in compliance with Florida Building Code 1518.2 when used in lieu of a code prescribed ASTM D 226 Type I1 underlayment. ...... ..... . . ..... 000000 . • . ...... • • NOA No.: 16-1216.02 Expiration Date: 02/07/22 Approval Date: 02/02/17 Page 2 of 3 LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. VersaShield® Fire -Resistant Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application. VersaShie1dSo1oTM Fire -Resistant Slip Sheet shall not be left exposed to the weather. 4. VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® SoloTM Fire -Resistant Slip Shber pre a component used in roof assemblies. Roof assemblies are approved under specific assembly) Iehee of ycerance. .... ••• • 5. VersaShield® Fire -Resistant Roof Deck Protection or VersaShielde Solon( Fire -Resistant Si' Sheet tha3r.1.2e used with any approved roof covering Notice of Acceptance listing. VersaShielde Fire-Resistant4toof Deck Protections or VersaShield® So1oTM Fire -Resistant Slip Sheet may be used as a component part of an a.sfi1ly in Ike oi; . • • •; Acceptance. If VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoloTM Pfi•Resista it Ship Sheets ... is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the M �am�.bade C�yy roduct.:.. Control Department for approval provided that appropriate documentation is provided to oompatibility of the ........ • • products, wind uplift resistance, and fire testing results. ' •• • •• 6. VersaShield® Fire -Resistant Roof Deck Protection and VersaShield® So1oTM Fire-Resissant,S p ShJ fir 'a non asphaltic underlayment that may be used as a fire barrier for prepared roof assemblies. •For fire clef cation ds' • • • specific roof assemblies using VersaShield® Fire -Resistant Roof Deck Protection or VersaShield®•3oloTM Fire - Resistant Slip Sheet refer to a current Approved Roofing Materials Directory for fire ratings of this product. 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, yellow line to identify the ASTM Standard designation or logo, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMMADE COUNTY APPROVED BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this material. END OF THIS ACCEPTANCE r.-. APPROVED NOA No.: 16-1216.02 Expiration Date: 02/07/22 Approval Date: 02/02/17 Page 3 of 3 TGFU.R10689 - Roofing Systems Page 1 of 3 ONLINE CERTIFICATIONS DIRECTORY TGFU.R10689 Roofing Systems Roofing Systems See General Information for Rooflna Systems GAP 1 CAMPUS DR PARSIPPANY, NJ 07054 USA Any UL Classified peel and stick underiayment may be used in conjunction with "VersaShletd® Fire -Resistant Roof Deck Protection" ai • • ; • "VersaShield® Underlayment" in any of the following systems. "• • • • • R1068111. •• • • • 1. Dada C-15/32 or spaced sheathing • •• • • • •••• •••••• • OTHER SYSTEMS • • • • • • • dese A Incliner Unlimited • • • • • • • •••••• • • • • • • • • • ••••• • . • • • • • • • • • • • Underlayment: — One ply "VersaShield® Fire -Resistant Roof Deck Protection" or "VersaShield® Underfaym i" mechanically fastened. Ply Sheet: — One ply Type 30 base sheet or "VersaShield® Flre-Resistant Roof Deck Protection" or "VersaShield® Underlaipgpe'. mechanically fastened. Shingles or Panels: — UL aassifled or Usted Steel or copper. 2. Deck: C-15/32 Indine: Unlimited Underlayment: — One ply "VersaShield® Fire -Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Shingles: — UL Classified or Listed Class A asphalt glass fiber shingle. 3. Deck: C-15/32 Indlne: Unlimited Underlayment: — TWo plies "VersaShield® Fire -Resistant Roof Deck Protection" or "VersaShield® Underlayment." Shingles or Panels: — UL Classified or Listed Aluminum. 4. Deck: C-15/32 Incline: Unlimited Underlaymer:1: — Three piles "VersaShield® Fire -Resistant Roof Deck Protection" or "VersaShleld® Underlayment." Membrane•. — Endur -All "Cedar -shake." 5. Dedk: C-15/32 or Spaced Sheathing Incline: Unlimited Underlayment: — One or more plies "VersaShield® Fire -Resistant Roof Deck Protection" or 'VersaShield® Underlayment" mechanically fastened. Panels: — Any UL Usted or Classified standing seam steel, steel or copper. 6. Dada C-15/32 or Spaced Sheathing Incline: Unlimited Underlayment: — One ply "VersaShield® Fire -Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Shingles: — UL Usted stone coated, direct to deck, non -batten systems. 7. Dodo C-15/32 or Spaced Sheathing Incline: Unlimited Underlayment: — One or more plies "VersaShield® Fire -Resistant Roof Deck Protection" or "Versashleld® Underiayment" mechanically fastened. Roof Panels: — Steel panels, fastened to 2 x 2 wood battens 8. Deck: C-15/32 Incline: Unlimited Underlayment: — One or more plies "VersaShleid® Fire -Resistant Roof Deck Protection" or "Versashleld® Underlayment" mechanically fastened. Shingles: — UL Classified or Listed Class A asphalt glass fiber shingle. 9. Deck: C-15/32 Incline: See Note Underlayment: — One or more piles "WeatherWatch®" or "StormGuard®", mechanically fastened. Slip Sheet: — One or more plies "VersaShield® SOLO'" Fire -Resistant Slip Sheet", mechanically fastened. Surfacing: — Any GAF Building Integrated Photovoltaic (BIPV) system, mechanically fastened. • • • http ://database.ul. com/cgi-bin/XY V /template/LI SEXT/ 1 FRAME/showpage.html?name=TG... 9/5/2017 NAND ti:C'U T DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Hurricane Roofing of Florida, Inc. 3438 W. 84 Street, Unit 111 Hialeah, FL 33018 MIAMI DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.¢ov/economy .... •• . .•.. • .. SCOPE: • •• . • This NOA is being issued under the applicable rules and regulations governing the use of catnstsuation materials. The. . documentation submitted has been reviewed and accepted by Miami -Dade County RER - Prodxot.Qontrol Section to be. used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction•(14HJ). • This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Pieduct Controll gection• (In Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) resew jlrq right to have this product or material tested for quality assurance purposes. If this product or material fails td perform in nbe:tcepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately? revoke, modify, on suspend the use of such product or material within their jurisdiction. RER reserves the right to evoke this a; ciptance : if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: DMC 150 SS — 0.032" Aluminum Panel over Plywood deck LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. • INSPECTION: A.copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 10. The submitted documentation was reviewed by Alex Tigera. NOA No.: 18-0807.01 Expiration Date: 08/30/2023 Approval Date: 08/30/2018 Page 1 of 10 •• • • ROOFING SYSTEM APPROVAL: Category: Sub-Catesorv: Material: Deck Tvne: Maximum Desien Pressure Roofing Metal, Panels (Non -Structural) Aluminum Wood —180 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANII: Test Snecifications Descrintian Product Dimensions DMC 150 SS —.032 Aluminum Panel 26 ga. DMC 150SS Fixed Clip Continuous Clip 24 ga. DMC 150SS Fixed Clip 22 ga. DMC 150SS Fixed Clip Length: various Height: 1-1/2" Width: 16" Thickness 0.032" Min Yield Sttength: 16ksi Length: 2" Height: 1-5/8" Width: 3/4" Thickness: 26ga Base: Length: 120" Height: 1-1/4" Width: 1" Thickness: 24ga Upper Clip: Length: 5.045" Height: 0.929" Width: 0.40" Thickness: 26ga Length: 2-1/4" Height: 1-5/8" Base Width: 15/16" Thickness: 24ga Length: 6-1/4" Height: 1-5/8" Base Width: 3/4" Thickness: 22ga TAS 110 • • . • .. . • .... • .. •. • .... • Aluminum standing seam Mitt! panel' . . .. . • . . . . • . • . • • . ... .. . . • • • Stainless steel panel clip used for the field cbnditions of DMC 150 SS panel assembly System A. . • Two piece panel clip (base and upper clip) used for the perimeter and corner conditions of DMC 150 SS panel assembly System A. One piece panel clip used for the field conditions of DMC 150 SS panel assembly System B. One piece panel clip used for the perimeter and corner conditions of DMC 150 SS panel assembly System B. NOA No.: 18-0807.01 Expiration Date: 08/30/2023 Approval Date: 08/30/2018 Page 2 of 10 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Liming Dimensions Bostik 70-05A EVIDENCE SUBMITTED: Test Agency Akzo Nobel Coatings, Inc. PRI Asphalt Technologies, Inc. Architecural Testing Architecural Testing Hurricane Test Laboratory, Inc. .E• APPROVED' N/A Teat Specifications TAS 110 Test Identifier Lab Form AKZC-001-02-01 AKZC-001-02-02 AKZC-001-02-03 AKZC-001-02-04 AKZC-001-02-05 DMC-005-02-01 DMC-008-02-01 56842.01-122-18 56842.02-122-18 0287-0513-07 Product Description Heavy duty construction adhesive. Test Name/R Dort ASTM G 153.' : . .. ASTMB i rr:" .'f0/b8/02 • TAS 125 .... . . .... TAS 100: TAS 125: TAS 100 TAS 125 • • • • . • . . • 04/26/13 :.(eijg/13 .Q8/Q3/05 '••08/e2/o5 05/10/07 NOA No.: 18-0807.01 Expiration Date: 08/30/2023 Approval Date: 08/30/2018 Page 3 of 10 APPROVED ASSEMBLE - . System A: ' MC 150SS 0.032" Aluminum 16" wide Panel Deck Type: Wood, Non -insulated Deck Description: New Construction 19/32" or greater plywood or wood pl Slope Range: Maximum Uplift Pressure: 2": 12" or greater See Table A below *000 Deck Attachment: In cerdafe.witl applicable-Riiilding Code, but in no case shall it• a less thpnJannular •, ring shank nails spaced 6" o.c. In reroofing, where the deck tii:1 s than* i9Y32" thief (Minimum 15/32") The above attachment method must be in additiM Id Zr dstingattachment. • ;• Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed•with a•m �i umum 44 .1 side -lap and 6" end -laps. Underlayment shall be fastened with 4M:in resi n-cap8 • • • • and 12 gauge 1 '/." annular ring -shank nails, spaced 6" o.c. at Ern' liPs and t vo staggered . rows 12" o.c. in the field of the roll or any approved underlaymen!M4 a current NOA. •• Fire Barrier Board: Any• • ry l• • . approved fire barrier having a current NOA. Refer to a currcpt f�•directeist•ing fob fire ratings of this roofing system assembly as well as the location•ff tht fire bitriier.,withid the assembly. See Limitation # 1. • • • Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with the current published installation instructions and details in DMC Association of Regional Manufacturers Installation Manual. Metal Panels and Install the " DMC 150SS .032" Aluminum 16" wide Panel" including flashing penetrations, Accessories: valleys, end laps and accessories in compliance . "DMC Association of Regional Manufacturers" current, published installation instructions and in compliance with the minimum requirements detailed in Roofing Application Standard RAS 133. Field Conditions: Panels shall be secured along the male rib with approved clips fastened with two corrosion resistant #10 pancake head fasteners of sufficient length to penetrate through the sheathing a minimum of 3/16". The panel clips shall be located at the maximum spacing listed in Table A below. • TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perim and Corn Maximum Design Pressures —71.25 —106.75 Maximum Clip Spacing 12" o.c. " , Clip 26 ga. DMC 150SS Fixed Clip Continuous Clip Mechanical Seam 180° 180° 1. Extrapolation shall not be allowed 2. Screws are alternated between one (1) and two (2) at the o.c. spacing NOA No.: 18-0807.01 Expiration Date: 08/30i2023 Approval Date: 08/30R018 Page 4 of 10 . System B: DMC 150SS 0.032" Aluminum 16" wide Panel Deck Type: Wood, Non -insulated Deck Description: New Construction 19/32" or greater plywood or wood plank. Slope Range: 2": 12" or greater Maximum Uplift See Table B below Pressure: • ... Deck Attachment: In accordance with applicable BuildingCode, but in no case shall • Tole ldss th 8 • � � annular ring shank nails spaced at a maximum distance specified below ia.Table B. lin 3nrobfing, • where the deck is less than 19/32" thick (Minimum's/32") The above•atttaojmient method must. be in addition to existing attachment. • • • . •• • Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a u ininaum 4" • • side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resisiiit'tifi-caps and 12 gauge 1 'A" annular ring -shank nails, spaced 6" o.c. at al�•leps:and two staggered .' rows 12" o.c. in the field of the roll or any approved underlayment'having a curregt•NQA. • Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a currentfiie $irectory.listing for fire ratings of this roofing system assembly as well as the location of the fire b'arsies within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with the current published installation instructions and details in DMC Association of Regional Manufacturers Installation Manual. Metal Panels and Install the "DMC 150SS 0.032" Aluminum 16" wide Panel" including flashing penetrations, Accessories: valleys, end laps and accessories in compliance "DMC Association of Regional Manufacturers" current, published installation instructions and in compliance with . the minimum requirements detailed in Roofing Application Standard RAS 133. Panels shall be secured along the male rib with approved Panel clip listed below in. Table B with two corrosion resistant #10 pancake head fasteners of sufficient length to penetrate through the sheathing a minimum of 3/16". The panel clips are to be placed at a spacing listed below in Table B. The female rib of panel is placed over the male/clip assembly and seamed. See Detail B herein. TABLE B MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner' Maximum Design Pressures -90psf —180psf Plywood Fastener Spacing 6" o.c. 4 o.c. Clip Type 24 ga. DMC 150SS Fixed Clip 22 ga. DMC 150SS Fixed Clip Maximum Clip Spacing 16" o.c. 8" o.c. Bostik Seam Sealant None (1) 1/4" bead Mechanical Seam 180° 180° 1. Extrapolation shall not be allowed NOA No.: 18-0807.01 Expiration Date: 08/30/2023 Approval Date: 08/30/2018 Page 5 of 10 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced'fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners). • • 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum length; • Roofing Application Standard RAS 133 8 shall•be as de�eril�ed in • 4. All panels shall be permanently labeled with the manufacturer's name and/or logo„ thy*gnd stge,•nd the. . • following statement: "Miami -Dade County Product Control Approved" or with the Mianii-Dhde County Product Control Seal as seen below. All clips shall be permanently labeled with the manufactii 4, § name aridl& logo, • • and/or model. • • • • • •� MIAMEDADE COUNTY APPROVED • • • • . • • • • •••••• • • • • • • • •• • •• •• • •• • •• • • • • • •• • 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 6. Panels may be jobsite roll formed with machine model # SO7950318 from DMC Association of Regional Manufacturers. NOA No.: 18-0807.01 Expiration Date: 08/30/2023 Approval Date: 08/30/2018 Page 6 of 10 • PROFILE DRAWINGS 16" 1/2" 3/8" 1." DCM 150 SS .032" Aumerum PANEL 26 GA & 24 GA DMC 150SS FIXED CLIP ' ' CON nNuous CLIP • • • • • • • • ••.. • . • • • • • • • • • • • • • • • • • • • • •. • •• • • .• NOA No.: 18-0807.01 Expiration Date: 08/30/2023 Approval Date: 08/30/2018 Page 7of10 • • • • • • • •• • • • • 22 GA DMC 150SS FIXED CLIP • . • .. .. . • . . • .. .. • . . • • • • . . NOA No.: 18-0807.01 Expiration Date: 08/30/2023 Approval Date: 08/30/2018 Page 8 of 10 • • • • • • .� • • • DETAIL A 0.c. (Field Conditions) 6" o.c \c typ. \\Nl #10 pancake head screws alternating quantity between 2 and 1 every 6" o.c. typ. • .... . . . .. .. • • •• •• • • • • •••• • • • • • • • • • • • • • • • • • • • •• • (Perimeter and Corner Conditions) • • •• • • • • NOA No.: 18-0807.01 Expiration Date: 08/30/2023 Approval Date: 08/30/2018 Page 9 of 10 • • • • • • DETAIL B DMC 1508S PANEL DMC 15OSS CUP (2)#10-13x1"PHW UNDERLAYMENT SUBSTRATE (Field Condition Seam Detail) CORNER mNE SEAM ADHESIVE (I/4" BEAD BMOC 70.05A) DPAC 15088 PAhIEL DMC 150SS CLIP (2)810-13x1"PHW UNDERLAYMENT SUBSTRATE (Perimeter and Corner Condition Seam Detail) END OF THIS ACCEPTANCE .. APPROVED .... . • . .... • . .. . • .... .• .. • . • .•• • • .. .. . .... • • • . • •. • . •• • . • .. . . . .. . • • • NOA No.: 18-0807.01 Expiration Date: 08/30/2023 Approval Date: 08/30/2018 Page 10 of 10 • • • • • • • TGFU.R15279 - Roofing Systems Page 1 of 2 ONLINE_CERTIFICATIONS DIRE.CTORY Paoe Bot_ tom See general Information for Rooflno Systems DREXEL METALS, INC. 6930 SAN TOMAS RD, SUITE A ELKRIDGE, MD 21075 USA TGFU.R15279 Roofing Systems Roofing Systems OTHER SYSTEMS •.•.• • • • • • • • • .• • •• • • •• • • • • • • • • • • • • .••. a w • • • • • • • • • • • • •• •• • R11279• • • • • • • • • • • • • • • • • • • •• • •• • • • • . •• • Clap A Metal panels Identified as *DMC 5-V, DMC 200S, DMC 175S, DMC 150SL, DMC 150SS, DMC 100SS, DMC 450SL and DMC LOONS". One or more layers of Elk Corp. "VersaShleld Underlayment," mechanically fastened, may be used in lieu of the Barrier Board In all combustible Classifications. 1, Deck: C-15/32 Incline: Un&mlbed Impacts Class 4 Barrier Board: — 1/4 In. min. G-P Gypsum DensDeck® with all Joints staggered a min of 6 in. from the plywood Joints. Ply Sheet (Optional), My UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or GCP Applied Technologies Inc. 'Ice and Water Shield". Surfo:Inas — Coated Steel, aluminum or copper roofing panels, mechanically fastened or with steel screws when roof deck fasteners (panel dips) not required. 2. Decks NC Inclines Unlimited Impacts Class 4 Barrier Boards — 1/4 In. min. G-P Gypsum DensDeck®. Ply Sheet (Optional): — My UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or GCP Applied Technologies Inc. *Ice and Water Shield'. Surfacing: — Coated Steel, aluminum or copper roofing panels, mechanically fastened or with steel screws when roof deck fasteners (panel dips) not required. 3. Decks NC Incline: Unlimited Impacts pass 4 Barrier Boards — 7/16 OBS or 5/6 in. plywood over polyisocyanurate Insulation board or polyisocyanurate composite boad, any thickness, Ply Sheet (Optional): — Any UL Classified Type GI, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or GCP Applied Technologies Inc. "Ice and Water Shield*. Surfaclng: — Coated Steel, aluminum or copper roofing panels, mechanically fastened or with steel screws when roof deck fasteners (panel dips) not required. 4, Deck: NC Incline: Unlimited Impact: Class 4 Insulations — Polylsocyanurate, .glass fiber, perlite or wood fiber, any thickness. Ply Sheet (Optional)s — Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or GCP Apply Technologies Inc. "ice and Water Shield°. Surfacing' — Coated Steel, aluminum or copper roofing panels, mechanically fastened or with steel screws when roof deck fasteners (panel dips) not required. 5. Decks NC Incline: Unlimited Impact: Gass 4 Insulation: — None required, however any UL Classified insulations may be used over open puriin spans. Any combination and any total thickness of insulation may be used. Surfacing: — Coated Steel, aluminum or copper roofing panels, mechanically fastened or with steel screws when roof deck fasteners (panel dips) not required. 6. Decks C-15/32 Inclines Unlimited impacts Class 4 Barker Board: — 1/4 In. min. G-P Gypsum DensDeck® with all Joints staggered a min of 6 In. from the plywood Joints. Ply Sheet (Optional): — Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or GCP Applied Technologies Inc. Ice and Water Shield". http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=TG... 8/8/2018 TGFU.R15279 - Roofing Systems Page 2 of 2 Surfacing: — Coated Steel, aluminum or copper roofing panels, mechanically fastened or with steel screws when roof deck fasteners (panel dips) not required. Class C Coated steel panels (surfacing) Identified as "DMC 5-V", "DMC 200S", "DMC 175S", "DMC 150SL", "DMC 150SS", "DMC 450SL" and "DMC 100NS". Aluminum panels identified as "DMC 1755". Copper panels identified as "DMC 100SS". 1. Deck: C-15/32 Incline: Unlimited Surfadng: — Coated Steel, aluminum or copper roofing panels, mechanically fastened or with steel screws whgn roo(dedc fasttgyn • (panel clips) not required, ' • s • • Lealigiggad on 2017-10-13 Oussugne print this Dame Ierms of t65g •• • • •• • • Emile ••• • • • • • • • • • • • •••••• • • • • • "' C1 2018 UL LLC • • The appearance of a company's name or product In this database does not In Itself assure that products so Identified hove been • manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be C&efed and covered under UL's Follow -Up Service. Always look for the Mark on the product. • • • • • • UL permits the reproduction of the material contained In the Online Certification Directory subjectto the followlhg conditions: 1'1 awe • Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and is a non- • • misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from thebalit (prbf catiog§$,, Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must Incyudb a' • • • copyright notice In the following format: "® 2018 UL • • • http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=TG... 8/8/2018 • 111111111111111. Roofing Systems + Custom Fabrication e% Install Guide . . • • • • • • • • . .. • .. . .. • • • • • .• •• DMC150SS Over Plywood: • • • • • • • • • • • ••• • •• • • • • • •• •• • LAST UPDATED: 2/17 • • .• Louisville — Baltimore — Tampa — Denver — Philadelphia (p) 888.321.9630 www.drexelmetals.com (f) 877.321.9638 • • DMC 150SS - SOLID SUBSTRATE DMC 150SS PANEL DREXEL APPROVED SEALANT (OPTIONAL) --\\ (FIELD OR MACHINE APPLIED SEALANT) DMC 150SS BUTTERFLY CLIP (2) #10 - 13 x 1" PHW METSHIELD UNDERLAYMENT - 1/2" PLYWOOD MIN. /\ - \ \ \ ZOOMED IN VIEW - EFFECTIVE DATE: 01-11-13 NTS I • N i 1 CROSS SECTION CROSS SECTION CROSS SECTION \ BEFORE SEAMING 90° SEAMING 180° SEAMING SEAMER TOOL RENTAL SEAMER TOOLS, INC. 8265 HIGHWAY 178 OLIVE BRANCH, MS 38654 PH:(662)895-1222 FAX: (662)890-4775 RENT@SEAMERTOOLS.COM • .. ... . . . .. .. • . . • . • .. ... .. . . . .. • .•. ... ... •. • • . . ▪ . • • • . • .. • . • . • . • . • . .• •. •. . . . . • . INSTALLATION DETAIL• fL SUBJECT TO CHANGE WITHOUT NOTICE SCALE: 3" = 1'-0" : :. • Itc0Atoig Sys120$ Custom Fabrication DMC 150SS - PLYWOOD ZOOMED IN VIEW i EFFECTIVE DATE: 01-04-13 DMC 150SS PANEL / r— ---- -- #10 - 13 x 1" PHW (12" o.c.) / i — UNDERLAYMENT i — -�- -� ` DREXEL APPROVED TUBE SEALANT i / -7N (FIELD APPLIED BETWEEN PANEL RIBS) / -1_= METSHIELD UNDERLAYMENT i -i FIELD CUT & HEM PANEL 180° DRIP EDGE SUBJECT TO CHANGE WITHOUT NOTICE SCALE: 3" = 1'-0" DRIP EDGE FLASHING 1 FASCIA FLASHING • •• • • • • • . .. .. . . . . . .. ... .. . .... • .•. .....• .• . •. . . . . . • • • • •• •• •.. •.• • . . . •• • • .• .• • .. . . . . • • • • • • • • . Itobtag Systkis 3- Custom Fabrication ... . . . ... . . DMC 150SS - PLYWOOD ZOOMED IN VIEW EFFECTIVE DATE: 01-04-13 / / / / NTS ----- .__..._------_.-_- 1/8" - #43 POP RIVET (18" o.c.) ,r Z-CLOSURE FLASHING / i '---- DMC 150SS PANEL (FIELD CUTAND BEND) i-----____. #10 - 13 x 1" PHW (12" o.c.) /� / / -_. D.B. TAPE SEALANT �� / ��-- METSHIELD UNDERLAYMENT / /' i�• / , PLYWOOD SUBSTRATE (1/2" MIN.) GABLE FLASHING l/ /// #10 - 13 x 1" PHW (12" o.c.) GABLE CLEAT FLASHING FASCIA FLASHING GABLE SUBJECT TO CHANGE WITHOUT NOTICE SCALE: 3" = 1'-0" ON MODULE #12 - 14 x 1 1/2" DP3 SD DREXMET HEAD (12" o.c.) —FLOATING RAKE ANGLE --#10 - 13 x 1" PHW (12" o.c.) NOT TO BE TIGHTENED FLOATING GABLE •..•... . .. .. • • . • • • • • • •. •.• •. . • . .• • •.• .•. •.. .• • • • • • • • • • • ▪ •• • • • . • . ▪ • • • •. .. •• • . • • • • a\ • • � • •• :•.' • 8•obfihg $ystb�dsZ% ; Custom Fabrication - DMC 150SS - PLYWOOD CONT. BUTYL TAPE SEALANT NOTE: PROVIDE HEAT RATED SILICON ROOF BOOTS,, EFFECTIVE DATE: 01-18-2013 SUBJECT TO CHANGE WITHOUT NOTICE F A::'ENER2. l'. C. -- PA^1E! ._..` \ :N IJ(.C.RitTt APPROVED !oRF SEALANT DE7WEEN PIPE BOO( AND PANEL �/'--- ME?:-•l1IEI) I:NI)LR:Ar MFNT •• ••• • • • • • •• T • • • • . • • ••• ••• .• • • • •• - Cx:!-.T:NC PLYWOOD DECK; CUT HD: E IN FI[CK AT LEAST 2- GREATER THAN PPE HOOT TLANC): • ••• ••• ••• •• • • • • • • • • • • • • • • •• • • • • • • • • • •• •• •• • • •• • • • • • • • PIPE FLASHING DETAIL { `two= a SCALE: NTS •. • • Custom Fabrication =Ai" DMC 150SS - PLYWOOD EFFECTIVE DATE: 01-04-13 SUBJECT TO CHANGE WITHOUT NOTICE DMC 150SS PANEL __- 1/8" - #43 POP RIVET (18" o.c.) Z-CLOSURE FLASHING RIDGE / HIP FLASHING DREXELAPPROVED TUBE SEALANT — _ X BOX END OF PANEL z (SEE ZEE CLOSURE OPTIONS DETAIL) #10 - 13 x 1" PHW (5 PER PANEL) D.B. TAPE SEALANT METSHIELD UNDERLAYMENT - PLYWOOD SUBSTRATE (1/2" MIN.) #10-13x1" PHW (5 PER PANEL) FLUSH CUT ZEE CLOSURE TO BE INSTALLED BETWEEN PANE RIBS w/ TUBE SEALANT AT SIDES AND IN ANY VOIDS RIDGE / HIP SCALE: 3" =1'-0" ZOOMED IN VIEW ! I' • • ' • . • • •• • • • • •� • • • •• •. .,1.• . . • • • .• ti • .•• .•• ••• • • . • • . • • . • • . • • • . .• •. •• • . . • • • NTS • • • . • • • • q x., iy \ • • : •Doblifigoixstetart Custom Fabrication �//i DMC 150SS -PLYWOOD I DMC 150SS PANEL #10 - 13 x 1" PHW (12" o.c.) D.B. TAPE SEALANT OFFSET CLEAT FLASHING FIELD CUT & HEM PANEL 180° BOX END OF PANEL (SEE ZEE CLOSURE OPTIONS DETAIL) TRANSITION FLASHING 1/8" - #43 POP RIVET (18" o.c.) Z-CLOSURE —� \ #10 - 13 x 1" PHW (5 PER PANEL) \ • D.B. TAPE SEALANT 'Ny\ PLYWOOD SUBSTRATE (1/2" MIN.)•,� DMC 150SS PANEL 1 METSHIELD UNDERLAYMENT -- #10-13x1" PHW (5 PER PANEL) FLUSH CUT ZEE CLOSURE TO BE INSTALLED BETWEEN PANE RIBS w/ TUBE SEALANT AT SIDES AND IN ANY VOIDS EFFECTIVE DATE: 01-04-13 N 1\ / 1 1 % DREXEL APPROVED TUBE SEALANT (FIELD APPLIED BETWEEN PANEL RIBS) `ZOOMED IN VIEW / . n . 1 /__ • •• • • • • • • • • \ ZOOMED IN VIEW V-- 7 • • .•. • ••,�• • .; •• • • / / • • • NTS ••• • • •• •• • • • TRANSITION SUBJECT TO CHANGE WITHOUT NOTICE SCALE: 3" =11-0" • • • • • • • •• • • • • • •• • • • •• • • • • • • • .. • : • : • • ItobritwAtstOrnef Custom Fabrication DMC 150SS - PLYWOOD I DMC 150SS PANEL #10 - 13 x 1" PHW (12" o.c.) D.B. TAPE SEALANT OFFSET CLEAT FLASHING FIELD CUT & HEM PANEL 180° BOX END OF PANEL (SEE ZEE CLOSURE OPTIONS DETAIL) TRANSITION FLASHING 1/8" - #43 POP RIVET (18" o.c.) \ Z-CLOSURE #10 - 13 x 1" PHW (5 PER PANEL) D.B. TAPE SEALANT PLYWOOD SUBSTRATE (1/2" MIN.) - DMC 150SS PANEL - - - METSHIELD UNDERLAYMENT #10-13x1" PHW (5 PER PANEL) FLUSH CUT ZEE CLOSURE TO BE INSTALLED BETWEEN PANE RIBS w/ TUBE SEALANT AT SIDES AND IN ANY VOIDS EFFECTIVE DATE: 01-04-13 SUBJECT TO CHANGE WITHOUT NOTICE SCALE: 3" = / / DREXEL APPROVED TUBE SEALANT (FIELD APPLIED BETWEEN PANEL RIBS) ZOOMED INVIEW ) 7 • ZOOMED INVIEW / /• /•1 • •-•-• • ID • •.:.• • • • -..., ---' -...._ •-- • • • • • • • • • --- -1 • • • • NTS • • • • • • • • • • • • • • • • • • • • • • • • • • • • TRANSITION • • • • • • • 9 • • ' ;1;:10.' " '''k-'.4 4EW'.e'it ',..:N.qt, • • • • •'!-IVI: 0 : • : • ITh Otat Sikeil 4ustom Fabrication •• Drexel Roofing Systems + Custom FabdcaO �\ O Linen White a Granite O Aspen Bronze ❑ Midnight Green O Classic Bronze ❑ Nantucket Gray • ❑ Traditional Black ❑ Chestnut Brown ❑ Pine ❑ Autumn Red ❑ Antique Metal • It THE roof OVER YOUR HEAD Your home is your sanctuary. Where your favorite memories are made. It protects your family and is a reflection of who you are. The roof is a major focal point of your home's design and architecture. Whether your style is open and breezy by the bay, Spanish Colonial, Victorian, or anything in between, there is a metal roof to cap off the story of your home. D R E X E L METAL quality For over three decades of industry expertise, Drexel Metals has earned a reputation for producing roofing systems of exceptional quality, safety, energy efficiency and performance. Our depth of experience combines with a passion for delivering industry -advancing innovation, while maximizing cost efficiencies and sustainability. Best of all, Drexel Metals Roofing Systems are made locally for you. unmatched DURABILITY The roof in your home is a major line of defense against the power of mother nature. While a common choice is asphalt shingles, a metal roof is the premier product for strength, longevity and carefree maintenance. Asphalt roofing - primarily made of oil-pregnated paper or fiberglass - begins to deteriorate as soon as it's installed. Likewise, wood shingles dry out and crack over time, and concrete roof tile can fracture from freeze/thaw cycles. Beautiful and strong, Drexel Metals Roofing Systems are precision -engineered to withstand decades of extreme weather like gale and hurricane force winds, heavy snow, hailstorms, and even wildfires. It will not deteriorate and is virtually maintenance free. I � ARE � � � . � Thisisthe#iquestionwe�ctaskcd�Thc�ns�e,isnuOv,mof aetypka|�in��Urd � � over your attic space with insulation plus your roof deck and our underlayrnent, This makes our metal roofs no more noisy than other roofing materials on the market. LIGHT ASAFEATHER Well, maybe not afeather, but ametal 000fisonaveragc50%|ightc,thunanasphalt shingle roof and 75% lighter than concrete tile, fiber cement shakes and slate. ,"'�tal roofing is a popular choice for homes in areas with heavy snowfall. A metal roof " '�ecls snow quickly, thereby protecting the integrity of the roof and eliminating ice " damming at the eaves that can cause water back up and eventually leak into your home, � CUSTOM BEAUTY +APPEAL charming and traditional. We offer a broad scope of profiles, styles and colors to infuse Luxurious colors, dramatic lines and graceful curves - from sleek and modern to w — constructed with products proudly made inthe USA and F|R`c+--|GH'--TN�G--SA~—T~~»nN�� Metal roofs are safer than most roofing material in the evefit of a"llghfriing !�, The y are not combustible and are less likely to start a fire. Also, Drexel Metal�-' �— carry ULc|ass "A" fire rating for roof coverings., which to resist the spread DREXEL METALS HOME COLOR COLLECTION REGAL WHITE SANDSTONE SLATE BLUE AGED COPPER SR 65 BONE WHITE SR 49 SR .32 SR .45 SIERRA TAN PACIFIC BLUE PATINA GREEN SR .66 SR .29 SR .29 SR .36 ALMOND SR .54 BUCKSKIN SR .38 DEEP BLUE SEA SR .29 TEAL BLUE SR .29 HEMLOCK SR .28 FOREST GREEN SR .30 SR = Solar Reference HARTFORD GREEN SR .27 Find out more about the benefits of metal roofing. Visit drexelmetalshome.com. Get started on your roof today by contacting info@drexmet.com or calling 888-321-9630. PERFORMANCE + SAFETY STANDARDS At Drexel Metals, every product and every project begins with a focus on safety and performance. We strictly adhere to quality assurance standards to ensure our installed roofing systems meet or exceed local and national building code requirements. Our products are tested to withstand gale to hurricane force winds, hail, fire, and wind -driven rain through independent testing and certification. For a complete list of testing and performance data, please visit www.drexelmetals.com. Warranty Protection Drexel Metals stands behind our products with industry -leading warranties, including a 35-Year Gold Standard Warranty that covers labor, adhesion, chalk and fade protection and is transferable from owner to owner for the period of the warranty. For complete warranty information, including limitations, ask your contractor for a copy of the Drexel Metals Roofing Systems warranty. Roofing Systems + Custom Fabrication A COMPANY drexelmetals.com Toll Free: 888-321-9630 Fax: 877-321-9638 Better Homes and Gardens, "11 Ways to Boost Curb Appeal," www.bhg.com/home-improvement/exteriors/curb-appeal/boost-curb-appeal. ENERGY STAR PARTNER © 2017 Drexel Metals, Inc. All rights reserved. Trademarks mentioned in this document are the property of Drexel Metals, Inc., its affiliates, or their respective owners. Colors shown represent the actual color as closely as possible. To ensure exact color for final approval, a metal color chip is available. Warranty statements mentioned are outlines; complete Limited Warranty information is available upon request. No other warranty expressed or implied is applicable. Printed in the USA 2017. © 2017 The Valspar Corporation. All Rights Reserved. Drexel Metals is a division of Carlisle Companies (NYSE:CSL). DOVE GRAY TERRA COTTA MEDIUM BRONZE MATTE BLACK SR .31 SR .41 SLATE GRAY COLONIAL RED SR .37 CHARCOAL GRAY SR .27 SR .33 SR 30 MANSARD BROWN SR .27 SR .30 BURGUNDY DARK BRONZE SR .33 SR .29 PREMIUM COLLECTION BRILLIANCE RED premium SR .41 METALLIC COPPER premium SR .42 BRIGHT SILVER premium SR .53 CHAMPAGNE premium SR .35 PREWEATHERED GALVALUME" SR 35 premium LOW GLOSS COLLECTION LINEN WHITE AUTUMN RED SR .72 SR .32 PINE SR .31 CHESTNUT BROWN SR .28 NANTUCKET GRAY ASPEN BRONZE MIDNIGHT GREEN ANTIQUE METAL SPECIAL PRINTpremiurn SR.37 SR 30 CLASSIC BRONZE GRANITE SR .28 SR .27 SR .27 TRADITIONAL BLACK SR .30 SR .34 ROOFINOX TIN COATED STAINLESS NATURAL METALS VM ANTHRA ZINC VM ZINC QUARTZ - LIFESPAN COMPARISON - METAL j0-60 1eorr or wore NON-METAL NEW 10 yr 20 yr 30 yr 40 yr 50 yr WHILE THE INITIAL COSTS OF A METAL ROOF MAY BE HIGHER THAN ASPHALT SHINGLES, A METAL ROOF IS THE better investment IN THE LONG RUN. + FAST FACTS ENERGY EFFICIENT Drexel Metals Roofs reflect rather than absorb the sun's heat energy, which makes it one of the most energy efficient roof systems available. THE GREEN CHOICE Keeping your home warmer in winter and cooler in summer with reduced energy spending is just part of the green story. MADE OF 30-60% RECYCLED MATERIAL 100% RECYCLABLE LIFESPAN Metal roofs last 2 - 3 TIMES LONGER than asphalt roofs. Virtually maintenance free. No intermittent repair costs. ATTRACT POTENTIAL BUYERS A roof can account for 40% of a home's visual impact from the curb' and help attract potential buyers should you decide to sell. GOLD STANDARD TRANSFERABLE WARRANTY Drexel Metals is the ONLY metal roofing company that provides a warranty that can be transfered to the next owner if you sell your home. CREATE ROOF ENVY Drexel Metals Roofs are more than just smart, financially superior investments. They are visually stunning. You'll be the envy of the neighborhood.