EL-18-3119Miami Shores Village
10050 NE 2 Ave
Miami Shores FL 33138
305-795-2204
Location Address
rr,
C�
,.J
Issue Date: 11/05/2018
Permit NO.: EL-10-18-3119
Permit Type. Electrical - Residential
Work Classification: Generator
Permit Status: Approved
Expiration: 04/08/2019
Parcel Number
905 NE 92ND ST, Miami Shores, FL 33138
Contacts
GARRETT SCHAEFER
905 NE 92 ST, MIAMI SHORES, FL 33138
Mobile: 9178421768
Owner
Description: ELECTRICAL WORK FOR NEE 27KW GENERATOR
AND AUTOMATIC TRANSFER SWITCH .
Fees
Amount
Application Fee - Other
CCF
DBPR Fee
DCA Fee
Education Surcharge
Permit Fee
Scanning Fee
Structural Review ($45)
Technology Fee
$50.00
$10.20
$8.76
$5.84
$3.40
$533.91
$12.00
$45.00
$14.60
Total: $683.71
ALL QUALITY ELECTRICAL SERVICES, INC
SAMUEL LIGHTBOURNE
14500 NW 16 CT, MIAMI, FL 33167
Business: 3059687832
Contractor
Valuation: $ 16,683.00
Total Sq Feet: 0.00
1
Inspection Requests:
30062494
Payments
Total Fees
Credit Card
Credit Card
Amount Due:
Date Paid
10/10/2018
11/05/2018
Amt Paid
$683.71
$50.00
$633.71
$0.00
Building Department Copy
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores
Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate
permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
O • . RS AF D VIT: I certify that all thforego ng information is ccurate acid that all work will be done in compliance with all applicable laws
ing con .tru ti and zoning. Fut erm re I h rize the aqq��ve n me contr ctor to do the work stated.
a 6�✓7`� G (t)Kf
lilt /1V
Authorized Signature: Owner / Applicant / Contractor / Agent Date
November 05, 2018
Page 2 of 2
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Ave, Miami Shores, Florida 33138
Tel: 305-795-2204 Fax: 305-756-8972
Inspection Number: INSP-001924-2018
Permit Number: EL-10-18-3119
Scheduled Inspection Date: November 28, 2018
Inspector: DeVaney, Michael
Owner: GARRETT SCHAEFER
Address:
Project:
905 NE 92ND ST
Miami Shores, FL 33138
Contractor: ALL QUALITY ELECTRICAL SERVICES, INC
SAMUEL LIGHTBOURNE
Permit Type: Electrical - Residential
Inspection Type: Electrical Final
Work Classification: Generator
Phone Number: 9178421768
Parcel Number: 1132060050010
Phone Number: 3059687832
Building Department Comments
ELECTRICAL WORK FOR NEE 27KW GENERATOR AND AUTOMATIC TRANSFER SWITCH.
Checklist Item
General Comments
Passed
False
Comments
Inspector Comments
Passed
Failed
Correction
Needed
Re -Inspection
Fee
No Additional Inspections can be scheduled until
re -inspection fee is paid.
November 27, 2018 For Inspections please call: 305-762-4949
Page 20 of 33
I-
BUILDING
PERMIT APP9CATION
❑BUILDING ELECTRIC
❑PLUMBING ❑ MECHANICAL
JOB ADDRESS:
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
RECEIVE"_
T 10 018,
Cam "
FBC 20 1k
Master Permit No. GL.i
Sub Permit No.
❑ ROOFING El REVISION - ❑EXTENSION El RENEWAL
❑ PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑SHOP
CONTRACTOR DRAWINGS
ZIP:
Oty: Miami Shores County: Miami Dade 3(3f3,
Folio/Parcel#: �� 3 s - ga0�, %a Is the Building Historically Designated: Yes NO
Occupancy Type: S F Load: Construction Type: t 6S Flood Zone: /V BFE: FFE:
e/ t�OWNER: Name (Fee Simple Titleholder): CO/ ✓ YJ2C.' J t '. Phone#:
I'
( ///! "``--����
Address:
City:
Tenant/Lessee Name:
Email:
9178Y2/76(
: State: `•Zip: : 3 ! 3
Phone#:
CONTRACTOR: Company Name: WJ t� �{
Qualifier Name: c G G . �. v M �_ Phone#: 30r.
Certificate of Competency #: a5S-6OQ(9 - 7,
Phone#:
City: State: Zip:
j / f j
i d� /W Square/Linear Footage of Work: <d ., •s e✓t. -(
Addition ❑ Alteration New ElRepair/Replace ❑ Demolitiqn
• / /e/1.-
/2,eA4) ? 7 /6(.3 Q z v
Ad
dress: 7 % �t� .7, 10€4 r) fre
City: PSG �4LL / State: ! L •
.Q/b't-e"-ei-- 1'
State Certification or Registration #:
DESIGNER: Architect/Engineer
Address:
Value of Work for this ermit: $
Type of Work: Descrip ' n of Work: l i! (�/
G 1
cfya,n_s- I TG .
Phone#: Cr37 t; ;' 7132,
Zip: 33/ 47
Specify color of color thru tile: ,ij
Submittal Fee $ ' O Permit Fee $ _�-45; $ .r
CO/CC $
Scanning Fee $ Radon Fee $ �' DBPR $ e • _� Notary $
Technology Fee $ Training/Education Fee $ Double Fee $
Structural Reviews $
Bond $ i,—.Oo .
CA
(Revised02/24/2014)
TOTALFEE NOW DUE $ C.9..3 • /
I, I33- "
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
City State
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that ,all work, will be+done in compliance with all
applicable laws regulating construction and zoning.
:;..,
"WARNING''TO'OWNER: YOUR FAILURE TO RECORD,A. NOTICE- OF COMMENCEMENT MAY
RESULT IN YOUR_PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. It YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF,.COMMENCEMENT.'r. c.. ,
Notice to Applicant: As a condition to the issuance of o building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered tothe
person
whose property'is subject to attachment Also, a"certOed copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature
OWNER or AGENT
The for ing instru nt was ackn wledged before me this •
dr'of 20 I'zi' , by
dF e r , who is ersonallY known to
me or who has produced F(
r en awn an w o i a e an oa .
NOTARY PUBLIC:
Sign:
Prin
Sea
U u
F :nrr
- q —04t •
APPROVED B
Commission # FF 933693
My Comm. Expires Nov 4, 2019
Bonded through National Notary Assn.
Signature
CONTRACTOR
The fore g oing instruiti nt was acknifni'edged l efore me this
day gf
IT'
, 20 ___ . by
Nvho is.p'erseuallu_known to
as me or who has produced as
c
•
/ S
identification an w o t to a an oat
NOTARY PUBLIC:
Sign:
Prirft
i
Sea
jd B"L/ bans Examiner
.-��•s._e/ tit
. 41
Structural Review
• �- Notary Public -
State of Florida
. rrn t r r ; Commission # FF 933693
o?°'' My Comm.
Expires Nov 4, 2019
Bonded through National Notary Assn
**************
Zoning
Clerk
(Revtsed02/24/2014)
•
a
w
ry.
RECEIPT,NO''
• RENEWAL
5807970 ,,
^•y-•-w„�- .vu <lnaer.way�`fe ..'•a.r'S '_"_ ices-'i1�w
_. +• .ate..+. t
A d -
al FBusi ness Tax Face cat
iami,-;Dade County, State of'Florida:
-THISISNOTAB4-DO'HOT PAY,-
5567996::-'`
,BUSINESSNA M•E/LOCATION'
'ALL QUALITY ELECTRICAL, .'
SERVICES INC;
`14750:S'RIVER DR`
MLAMI;=FL' .33'167
,y
-=' -..
OWNER r• r" « SEC. TYPE OF BUSINESS
ALL QUALITY ELECTRICAL SVCStINC 196 i 'ELECTRICAL
}'' r I CONTRACTOR
HiArta
EX PI.RE,S
$EPTEMBER,30,. 2010[.
Must. be displayed at piece of • business'
Pursuant to'County�Code
Chapter 8A'- Art:'9•'8;10 y;" r�
•
I rt
IPAYMENT RECEIVED (A.' "
JBYTAX COLLECTOR }5 `'
.1'82 50 10/04/2018
,, 1orker(s) j 1 1 `, E 1''` , "' 05E000478' , a ' ` - 0200-19-000M I '
.,e, ; f.`'ThisLocalBusinessTaxlceiptodycon rmspaymentd.thelocalBusinessTax:Theoptisnotalibense,
"v' permit.oracerti^cationd he holder's qua' P'cations, todobusiness.Ibdermust oarplyWith any porerenta tel
V r' J ar! ixtgo er: men al regllataYlawsand rerrentswhich
�, , aPPlytotlietrainess.- P j
+ The Fittl3PTNQ above mat be displayed on all eonrrler'eial vehicles - Miami -Dade Code Sec 89-276..
' ForJmoireinfometion,visit wwwJT arnidade.gov/taxcollector' . ; •
0
M uni ci pal Contractor's Tax Re' cei cat
Miami -Dade County, State of •Florida:
-TtiiS'IS NOT,A BILL, :DO NOT PAY
CC NO:05E000471V .1.
• BUSINESS NAME/LOCATION
-
y ALL QUALITY a TRCAL aiRACES INC
14750 S FIVERDR
MIAMI, F6 33167 t,te. " 1,
OWNER
i.i
•
ALL QUAL IN. B.a1RCAL 91ICS INC ,
it r' q. ."€
�
�A# '' 1
MIAMMIADE
RECEIPT O.
7551815
t.
TYPE OF BUSINESS
'EXPIRES' ..
='SEP:TEM.BERL30,,201,9
BECTiaCAL CON1RAC"TORI -
,
Pursuant to County Code
Sec 10-24•
r
r-...
PAYMENT 'RECEIVED
BY TAX COLLECTOR • . 't
-'-04
200.00 T10/ 04/ 2018 1
oioa19-0000s4
E
For.•
6
6 :i 1 t 1 t,: ,
I . This receipt is not valid in thefdlawing Municipalities Avent ra, Dcral; Fialeeh, Key Biscayne,-
'•`""
f Miami Gardens, Miami lakes, Palmetto Bay, Pinecresn of Cutlert, Sunny Isles Beach, TON Bay
PLAN OF . SURVEY SCALE 1" =30'
to' farm Sly
'from Ka(
o11 0,,
- l0llL it rp�
j0'1 e 1 F �
l
1j,o ofvvAl Yti
(yona.010 t'DOVA. ill -VAT)
I Grw.— 13f.4"1 e
. kr.
F
-0uVO
,o/eG
ZS'
/
- SPA; z_e_rw- ,
ItCr
I
WOOF rcuCC
crYPlcAL)
LIPAI
11 o
Ic
u.E. 933(5T
• •
••
iy'A r P4YGY6zir--) ‘c>•
•
125'
15,8'
tn POOL
35.7'
= - = Tic,(S 41. - •• 3,0'
26.90' o . 24 30'
f.
86
o I STO Q/ C:B.S.
4.80'
m.
POLE
F, H,
45PJ192r
iIfC,
jAi `>.
/6.70' z5, ip /6.601
- n 1 h z220'
.srEP5
SPNAG
/29681_
f/z5oAteovA1
cis
•
•
• • • •
• • •
•
•••
• • •
•
•
•
•
•
•
•
k•••••• •
couvaile ar-A1Ce-
1--
Ea, YX 3'POOL j< co 2 *5
r�
,4',t8'4/C 0 t0i d
�ZfJbltTS) 117
AsPf4c r
eo u reo,
emuri,
w000 z o O
ce1JCE
.77
`;j/ � K) 0100 iz P/PE
(.10c i ))
'-POLE 46,etaL
Miami Shore3 Village
APPROVED
DATE
/3,00'
h
ti
M
•
•
•
(LV o) •
•
•
• • •
•• •
3x 3 FOOL PUNPs
•
4
N .. 9Zneisr �4` /
r
OCT. 1 0 2018
ING PINT
PLUMB ,��,7:� Aoo2�Y ,
Approved 9ZPialy/3� f
Selo:-gre, .33/B8
/
Disap �' wed
A ..ARC DISTANEE .. STRUCTURE O.U.L..OVERHEAD IITILTTY LINE CL..CU AR CA ---CENTER LINE
RAD...RAI IAL ENC.-ENCROACHMENT • RAN -RIGHT OF WAY... FIP...FOUND IRON PIPE O_H..,OVER HEAD - W.M_._WATER METER C_IL...CHORP
DISTANCE PIL..PROPERTY UNE CONC...CONCRETE F.H. FIRE HYDRANT - UP...UTIUTY POLE R_.RADIUS U.E...UTILTTY EASEMENT
A...CENTROL ANGLE R...RADIUS PL....PLANTER T..-TANGENT C.B.....CATCH BASIN MH.....MANHOLE CLF...CHAIN LINK FENCE W.F.....)NOOD FENCE
4' ZONING DEPT
BLDG DEPT
I I l.11 CT I (;OMPI IAr WITH ALL F
4-1 STAI 1= ANI) NOUN I Y RULES AND REGUI_AI IONS
�04-7 � 49 rt
A/C .AIR CONDTI7 IN CBS...CONCRETE BLOCK
T3VED
OT 0 18
PP-0
00it1D SPIKE
ou4SPHALT
PULE
F. H,
PLAN OF . SURVEY SCALE 1" =30'
26.70'
4.eo'
95P'/41r
%r tv 9a 51—
Ca e fi- Sc .11 ec. -i v'
IJ 1kLowh y
U.E. 93 st5i
.srEvs
o p4AC r
rZg681_
f/zsAmt AY
,.►
•
3z 3'PooL. O•4 PS
AsPp4G r
ti
NE. 92
ndsr ±H /PoveigeT-
FOUNDfi'piPF
60,9 c4,o)
ate
ate
el/4ijJ4/.Ukl re -wee
•
•
• • • •
•.•
•
••
• •
•• •
•
..>
•
• •
• • •
• •
•
••• • •
• • •
•. •
KD UIJD zPU°E
COO CAP)
POLE 4EVAL
"741E5
peQP k7/ADDfESS•
905 N. C. 9Z °'
A//, Ai / 5N OI E5, AZ . 33/678
A....ARC DISTANCE A/C...AIR CONDITIONING CBS...CONCRETE BLOCK STRUCTURE O.U.L...OVERHEAD UTILITY UNE CL...CLCAR C/L...CENTER UNE
RAD...RADIAL ENC..:ENCROACHMENT • RIW...RIGHT OF WAY... FIP...FOUND IRON PIPE O.H...OVER HEAD • W.M....WATER METER C.H.-CHORD
DISTANCE PIL...PROPERTY LINE CONC...CONCRETE F.H. FIRE HYDRANT UP...UTILITY POLE R...RADIUS U.E...UTIUTY EASEMENT
p...CENTRAL ANGLE R.. RADIUS • PL PLANTER T..-TANGENT C.B.....CATCH BASIN MH.....MANHOLE CLF...CHAIN. LINK FENCE W.F..„.WOOD FENCE
nor CORP
Service is our Foundation
Garrett Schaefer
905 NE 92 St.
Miami Shores, Fl. 33138
Dear Garrett,
RLV CORP is pleased to provide the following proposal:
1401 NE 101 St., Miami Shores, FI.33138
305-790-5899 bobvickers@bellsouth.net
Generac Dealer # 1020948
•
•
• •
....
Solution Description: RLV CORP will provide for a new RG02724ANAX - Commercial•Ssrnes: Brand.. • •
Protector Series Gaseous; Kilowatts - 27kW; Engine - 2.4 liter engine; Voltage - 120/240.1o; ue1 Type - •
Natural Gas; Enclosure - Aluminum Enclosure with matching whole house NEMA 3R 200.AM1: Single •
Phase Automatic Transfer Switch (ATS) with integrated Service Disconnect. • • • •
••. •
Scope of Installation: RLV CORP will provide for installation of generator on southweStcd▪ tller • side of"•
property, behind front wall line. 'A custom built concrete pad will be constructed having an3`inns of 70"'
long, 40" deep, by 10" high. RLV CORP will provide for and install all low and high voltage wiring lab., •: •
and materials. RLV CORP will supply all gas line labor and materials for connection betweenganeratoiaid•
TECO gas meter. Electric and Gai line trench'will be hand dug 36" deep from generator to 1`ECb/FPL• • • • •
meter area. RLV CORP will make every attempt to protect existing plant life, sprinkler, landscape lighting
and septic lines.
RLV CORP will provide for a 26R battery, system registration with Generac,: test and turn up, -documentation'
presentation, customer overview and acceptance. RLV CORP will apply for required Electric, Construction
and Plumbing permits. All permit fees assessed by city will be passed to customer.
Warranty: RLV CORP passes through Generac's limited 5 year warranty on generator and Transfer Switch.
RLV CORP warrants 'supplied installation materials and workmanship for a full 5 years. A one-year annual
service plan is included with this contract facilitating 2 site visits a year. Mobile 1 oil/filter change, fluid top
off lifetime battery and complete system check and test.
Material Description and Associated Labor:
Guardian Series Model RG02724ANAX -
200 AMP Single Phase, Automatic Transfer Switch, with Service Disconnect
Group 26R Battery
Gas line and electrical connections labor
Sub Total
7% Tax:
TOTAL:
$19,583.00
$1,370.81
$20,953.81
Installation Interval: Estimated installation time will take 60-90 days barring any unforeseen events
including material shortage, access limitations, acts of God, permitting delays and / or failure to make
scheduled payments.
A 60% deposit is required to start, with 40% due upon system test/turn up and customer acceptance.
We look forward to delivering a quality installation for you.
ACCEPTED AND AEED:
Signature:
G tt Schaefer - oi. 'V er
rt B. Vickers — President RLV Corp.
Quote valid for 30 days
Page 1 of 1 - 5/8/2018
Riser Diagram
Garrett Schaeffer
905 NE 92 St., Miami Shores, FI. 33138
Notes:
• All above ground conduit strapped with Unistrut
• Generator line buried from house wall to generator
36" deep
• Generator riser strapped with Unistrut to pad
• PVC conduit from ATS to generator is 2" with 2/0
wires for load
• PVC conduit from ATS to generator is 1" with 7
conductor low voltage wire for signaling
LASht5 l,-b-01,42 6-E 6 .Ldc 94
•
27kW:.Generator
10" High Concrete Pad
2" EMT Conduit w/ 2/0 wire 1 1 2" EMT Conduit w/ 2/0 wire
200 AMP
Automatic
Transfer
Switch with
Integrated
Service
Disconnect
2" Conduit w/ 2/0 wire for Toad, buried 36" •
Ci",dVhc
Q' qa,t✓ (tocL
• • • ••
•
• . •
• • • •
•• • ••• •• • • • ••
• ••• • ••• • •••
•• • • •• • • •• • •
• • • • • • • • •
• • • • • • • • • •
• • •• • • •• • • ••
• • • • • •
••. • • • • 0114, • •
• • • • • • • •
• • • 004 • • •
• • • • •
• •• •• • • • •• ••
••• • • • ••• • •
Interior
House Panel
All Quality Electrical Service Inc.
14750 S. River Dr.
Miami, FI. 33167
Qualifier:
Samuel Lightbourne
CC#05E000478
Job Name:
Residence of Garrett Schaeffer
905 NE 92 St.
Miami Shores, FI. 33138
Electrical Panel "A" Schedule
Type
Service
Voltage
Mounting
Poles
Square D
20, 3 wire
120/240V
Flush
20
Load Wire Breaker
1200 10 15A/1P
1500 12 20A/1P
5768 14 15A/1P
1500 12 20A/1P
14 15A/1P
14 15A/1P
14 15A/1P
1840 12 20A/2P
Equipment
Office
Lighting/Smoke D
Family Room Rec.
Bathroom
General Lighting
General Lighting
General Lighting
Pool Pump
Circuits
1
3
5
7
9
11
13
15
17
Main Bus
Nuetral
Mains
Location
A.I.C.
200 AMPS
FULL
M.L.O
Laundry
10,000A
Circuits Equipment Breaker Wire Load
2
4
6
8
10
12
14
16
18
Small Appli.
Small Appli.
A/C #1 Comp
Bath/Smk. Det
Dining Room
Mstr. Bedroom
Dishwasher
20A/1P
20A/1P
40A/2P
15A/1P
15A/1P
15A/1P
20A/1P
12
12
6
1500
1500
6500
14
14
14
12 1500
TOTAL WATTS LESS A/C UNITS - 19308 W
First 10000A at 100% = 10000W
Remainder at 40% = 3723W
A/C Units Load = 6500w
TOTAL PANEL LOAD = 19023 w / 240V = 78 AMPS
.. ..• . . . . . ..
•
• • .
• • • •
•
•• ••. •• • • • ••
• ... . ••• • •.•
• . . • • . •• ••
• •
• • • •• •• • •• •
• • • • •• •• • • •
• •
• • •• • • •• •• :•
• • • •
•
••• • • • • •.• • •
• • • • •• • • •
•
• • • ••• • • •
• •• • • • • •• •
• • •
• •• •• • • • •. ••
••• • • • ••• • •
All Quality Electrical Service Inc.
14750 S. River Dr.
Miami, FI. 33167
Qualifier:
Samuel Lightbourne
CC#05E000478
Job Name:
Residence of Garrett Schaeffer
905 NE 92 St.
Miami Shores, FI. 33138
Electrical Panel ' B" Schedule
Type
Service
Voltage
Mounting
Poles
Square D
20, 3 wire
120/240V
Flush
30
Load Wire Breaker
1840 12 20A/2P
5800 10 60A/2P AHU #1 Heat
4944 14 15A/1P
14 15A/1P
14 15A/1P
5800 8 20A/2P
Equipment
Sprinkler Pump
General Lighting
General Lighting
Master Bath
Dryer
spare
spare
spare
spare
spare
spare
Circuits
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
Main Bus
Nuetral
Mains
Location
A.I.C.
200 AMPS
FULL
M.L.O
Laundry
Hallway Add
Circuits Equipment
Breaker
Wire Load
2 A/C #2 Comp
4
6 Ext. Lights
8 Sprinkler
10 15A/1P
12 15A/1P
14 60A/2P
16
18
20
22
24
26
28
30
spare
spae
spare
spare
spare
spare
spare
40A/2P
15A/1P
20A/1P
Flood Lights
Gen. Lighting
AHU #2 Heat
6 5800
14
12 1840
14
14
10 5800
TOTAL WATTS LESS A/C UNITS - 29464 W
First 10000A at 100% = 10000W
Remainder at 40% = 7786W
A/C Units Load at 65% = 11600w
TOTAL PANEL LOAD = 17386 w / 240V = 92 AMPS
•
. .
- - - . - .
.. ... .. . . . ..
• ... • ... . 000
••
. . . • . . . . • . •
• . .. . . .. . . ..
• . • •
... • • • • ... • •
• • . •. •. • •
•
• • • ... • • •
• . . . . . ••
• • •
• .. .. • • • .. ..
000 • • • 000 . •
GENERAC®
Protector° QS PROTE T R®
pimiSC 0 QS SERIES
eries
Standby Generators
Liquid -Cooled Gaseous Engine
INCLUDES:
• Two Line LCD Multilingual Digital
EvolutionT' Controller (English/Spanish/
French/Portuguese) with external viewing
window for easy indication of generator
status and breaker position.
• True Power"' Electrical Technology
• Isochronous Electronic Governor
• Sound Attenuated Enclosure -
• Closed Coolant Recovery System
• Smart Battery Charger
• UV/Ozone Resistant Hoses
• -±1 % Voltage Regulation
• Natural Gas or LP Operation
• 5 Year Limited Warranty
• UL 2200 Listed
• Capability to be installed within 18"
(457) mm of a building*
*Only if located away from doors, windows, and fresh air
intakes, and unless otherwise directed by local codes.
'rotector® sT
1of11
Standby Power Rating
Model RG022 (Aluminum - Bisque) - 22 kW 60 Hz
-----Model RG027 (Aluminum - Bisque) -.27 R V 60 Hz
Model RG032 (Aluminun: - Qisque) -:Mk 60 I-L... •
Model RG038 (Aluminum - Bistiue) -.384 4 60 Hz • •
Model RG048 (Aluminum••bisque) - 481AN 60 112••••
•
•.•. •
•
• •
• . •
a�� • • .
mt.= _ - _
QUI
domale
••
•
Meets EPA Emission Regulations
22 & 27 kW are CA/MA emissions compliant
32 & 38 kW not for sale in CA / MA
•
FEATURES
O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of
GENERAC'S success in "IMPROVING POWER BY DESIGN." But it
doesn't stop there. Total commitment to component testing, reliability
testing, environmental testing, destruction and life testing, plus testing
to applicable CSA, NEMA, EGSA, and other standards, allows you to
choose GENERAC POWER SYSTEMS with the confidence that these
systems will provide superior performance.
O TEST CRITERIA:
1 PROTOTYPE TESTED
1 SYSTEM TORSIONAL TESTED
1 NEMA MG1-22 EVALUATION
1 MOTOR STARTING ABILITY
O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION.
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at ±1%.
O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
network provides parts and service know-how for the entire unit, from the
engine to the smallest electronic component.
O GENERAC TRANSFER SWITCHES. Long life and reliability are
synonymous with GENERAC POWER SYSTEMS. One reason for this
confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
GENERAC®
- 22.27.32.38.48kW
•••.
• ; • • yQLTAGE •
GENERAC®
application & engineering data
GENERATOR SPECIFICATIONS
•
O 000
•
Type
Synchronous
Rotor Insulation Class
H (22 & 27 kW) or
F (32, 38 & 48 kW)
Stator Insulation Class
H
Telephone Interference Factor (TIF)
<50
Alternator Output Leads 1-Phase
4 wire
Alternator Output Leads 3-Phase
6 wire
Bearings
Sealed Ball
Coupling • •
Flexible Disc
. jxcitation Slls%rr• ; •
- -
•
•
Direct
000
• •
•.• • •
•: • •GOVERNOR•SI=ECIFICATrdNd •
•
• • • •
•
•
7rpe
•
•
Electronic
.`
Sensing •
•
• • • •
Single Phase
•.
Re gulation
•.••
± 1%
.Type • •
•
•
•
Electronic
Foequency Regulation
•
• • ••
•
Isochronous
•-
Steady StateSeO j Mtion
•
• •
± 0.25%
ELECTRICAL SYSTEM
Battery Charge Alternator
12 Volt 30 Amp
Static Battery Charger
2.5 Amp
Recommended Battery (battery not included)
Group 26 (22, 27, 32 & 38 kW)
or Group 24F (48 kW), 525CCA
System Voltage
12 Volts
GENERATOR FEATURES
Revolving field heavy duty generator
Directly connected to the engine
Operating temperature rise 120 °C above a 40 °C ambient
Ciass H insulation is NEMA rated
Class F insulation is NEMA rated
AM models fully prototyped tested
ENCLOSURE FEATURES
Aluminum weather
protective enclosure
Ensures protection against mother nature.
Electrostatically applied textured epoxy paint for added
durability.
Enclosed critical grade
muffler
Quiet, critical grade muffler is mounted inside the unit
to prevent injuries.
Small, compact, attractive
Makes for an easy, eye appealing installation.
SAE
Sound attenuated enclosure ensures quiet operation.
(All ratings in accordance with BS5514, IS03046, IS08528, SAE J1349 and DIN6271)
ENGINE SPECIFICATIONS: 22, (27I 32 & 38 kW
Make
Generac
Model
In -line
Cylinders
4
Displacement (Liters)
' 2.4
Bore (in/mm)
3.41/86.5
Stroke (in/mm)
3.94/100
Compression Ratio
9.5:1
.
Intake Air System
Naturally Aspirated (22 & 27 kW) or
Turbocharged/Aftercooled
(32 & 38 kW)
Lifter Type
Hydraulic
ENGINE SPECIFICATIONS: 48 kW
e
enerac
Model
;
V-Type
Cylinders
8
Displacement (Liters)
5.4
Bore (in/mm)
3.55/90.2
Stroke (in/mm)
4.17/105.9
Compression Ratio
9:1
Intake Air Sys
Naturally Aspirated
Lifter
Hydraulic
ENGINE LUBRICATION SYSTEM
Oil Pump Type
Gear
Oil Filter Type
Full flow spin -on cartridge
Crankcase Capacity (qVl)
4/3.8 (22, 27, 32 & 38 kW) or
6/5.7 (48 kW)
ENGINE COOLING SYSTEM
Type
Closed
Water Pump
Belt driven
Fan Speed (rpm)
1980 - 22 & 27 kW
1500 - 32 & 38 kW
1954 - 48 kW
Fan Diameter (in/mm)
18.1/459.7 (22 & 27 kW) or
22/558.8 (32, 38 & 48 kW)
Fan Mode
Pusher (22 & 27 kW) or
Puller (32, 38 & 48 kW)
FUEL SYSTEM
Fuel Type
Natural gas, propane vapor
Carburetor
Down Draft
Secondary Fuel Regulator
Standard
Fuel Shut Off Solenoid
Standard
Operating Fuel Pressure
5-14" water column/9-26 mm HG
LP Fuel Pressure
11 -14" Water Column
NG Fuel Pressure
5 - 14" Water Column
GENERAC®
22.27.32.38.48,kW
operating data
GENERATOR OUTPUT VOLTAGE/kW - 60 Hz
kW LPG
Amp LPG
kW Nat. Gas
Amp Nat. Gas
CB Size (Both)
RG022
120/240 V, 10, 1.0 pf
22
92
22
92
100
120/208 V, 30, 0.8 pf
22
76
22
76
80
120/240 V, 30, 0.8 p1
22
66
22
66
80
RG027
120/240 V, 10, 1.0 pf
27
113
25
104
125
120/208 V, 30, 0.8 pf
27
94
,
25
87
100
120/240 V, 30, 0.8 pf
27
81
25
75
90
RG032
.
120/240 V, 10, 1.0 pf
32
133
32
133
150
120/208 V, 30, 0.8 pf
32
.• 111
•
,L1
32
111
- 125
•
120/240 V, 30, 0.8 pf
32
96
32
96 •
•• • • •1UQ
• •
277/480 V, 30, 0.8 p1
32
48
32
.
48 •. •
.00w
• • • G
0
RG038
120/240 V, 10, 1.0 pf
38
158
38
mi; • •
•
• • •195
• •
120/208 V, 30, 0.8 pf
38
132
38
ir
'150
; .
120/240 V, 30, 0.8 pf
38
114
38
••••
T1.4.•••
•
•••01126
•
277/480 V, 30, 0.8 pf
38
57
38
5Z • • • •
• • • 90
•.
RG048
120/240 V, 10, 1.0 pf
48
200
48
f200 • •
• • • • SOU
• .
120/208 V, 30, 0.8 pf
48
167
48
Z ff/' ; • ;
• 175
120/240 V, 30, 0.8 pf
48
144
48
144 •
: • • •: 1
• •
277/480 V, 30, 0.8 pf
48
72
48
•. •
7�
80
AA A
. •
SURGE CAPACITY IN AMPS
Voltage Dip @ < .4 pf
15% 30%
RG022
120/240 V, 10
55
135
120/208 V, 30
40
92
120/240 V, 30
35
80
RG027
120/240 V, 10
62
170
120/208 V, 30
70
120
120/240 V, 30
61
103
RG032
120/240 V, 10
75
180
120/208 V, 30
87
210
120/240 V, 30
75
182
277/480 V, 30
36
87
RG038
120/240 V, 10
75
180
120/208 V, 30
87
210
120/240 V, 30
75
182
277/480 V, 30
36
87
RG048
120/240 V, 10
85
195
120/208 V, 30
90
218
120/240 V, 30
78
189
277/480 V, 30
36
87
Note: Fuel pipe must be sized for full load.
For Btu content, multiply ft3/hr x 2520 (LP) or ft3/hr x 1000 (NG)
For megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG)
Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and
SCAOMD permitting purposes.
ENGINE FUEL CONSUMPTION
Natural Gas Propane
(ft3/hr) (m3/hr) (gal/hr) (I/hr) (ft3/hr)
•
•• •
RG022
Exercise cycle
34
1.0
0.4
1.4
13
25% of rated load
142
4.0
1.4
8.2
52.5
50% of rated load
207
5.9
2.1
7.8
78.6
75% of rated load
274.6
7.8
2.9
10.9
104
100% of rated load
342
9.7
3.6
13.7
129.7
RG027
Exercise cycle
40
1.1
0.4
1.7
15
25% of rated load
155
4.4
1.6
6.2
58.7
50% of rated load
233
6.6
2.6
9.5
90.4
75% of rated load
314
8.9
3.3
12.7
121
100% of rated load
396
11.2
4.1
15.7
149
RG032
Exercise cycle
44
1.3
0.5
2
19
25% of rated load
138.8
3.9
1.5
5.7
53
50% of rated load
218.8
6.2
2.6
10.2
94.9
75% of rated load
301
8.5
3.7
14.2
132
100% of rated load
380.6
10.8
4.6
17.6
166
RG038
Exercise cycle
44
1.3
0.5
2
19
25% of rated load
156
4.4
1.7
6.4
60
50% of rated load
260
7.4
3
11.4
107.8
75% of rated load
361.7
10.2
4.2
16.2
153
100% of rated load
444
12.6
5.4
20.4
192
RG048
Exercise cycle
63
2.0
0.9
3.3
31
25% of rated load
270.6
7.7
3.1
11.7
110.9
50% of rated load
425
12.0
5.0
19
151
75% of rated load
557.7
15.8
6.8
25.8
244.5
100% of rated load
638
18.5
8.7
33
312
3of11
• ••
� •
••••
•
••••
•
• ••
• •
•• •
� •
• • • •
•
••••
•
STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There
is no overload capability for this rating. Ratings are in accordance with IS0-3046-1. Design and specifications are subject to change without notice.
4 of 1
22.27.32•.38.48kW
ENGINE COOLING
14(/
22 kW
27 kW
GENERAC®
operating data
32 & 38 kW
48 kW
Air flow (inlet air including alternator and combustion air in cfm/cmm)
2400/68
2400/68
2200/62.3
4350/123.2
System coolant capacity (gal/liters)
2.5/9.5
2.5/9.5
2.5/9.5
3/11.4
Heat rejection to coolant (BTU per hr/MJ per hr)
9,000/104.
105,000/110.8
145,000/153
186,000/196.2
Maximum operation air temperature on radiator (°C/°F)
60/ 50
Maximum ambient temperature (°C/°F)
50/140
COMBUSTION REQUIREMENTS
t
Flow at rails w
r2cfnVcmm) _
6V.9
68/1.9
106d
16)(4j
• . • •
• • SOUND EMMONS • •
0004,
• • • •
•
Sound output in dB(A) at 23 ib(i ;Owl* generator in exercise mode
/ 61 `
61
3
Sound outgt:Ipso) at 23 ft.(? fit�0itp generator operating at normal load*
70
70
r
4
\
68
. •' ;' found levels are taken from the front of the generator. Sound levels taken from other sides of the generator may e higher dending on installation parameters
• • • •
. .
••••EXHAUST••"
• • • •
•
• •
•• ••
'Exhaust flowst ratedoutput (chrVcmm)• ''
165/4.7
\
180/5.1
300/8.5
414/11.7
••-••-
• haust temperature'at mufller�Ti1{pt (° F)
482/900
538/1000
579/1075
r
552/1025
• ENGINE PAfilr+IETERS
Rated Synchronous rpm
1800
POWER ADJUSTMENT FOR AMBIENT CONDITIONS
Temperature Deration 3% for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F
Altitude Deration (22, 27 & 48 kW) 1 % for every 100 m above 183 m or 3% for every 1000 ft above 600 ft
Altitude Deration (32 & 38 kW) 1 % for every 100 m above 915 m or 3% for every 1000 ft above 3000 ft
CONTROLLER FEATURES
2-Line Plain Text LCD Display Simple user interface for ease of operation.
Mode Switch: Auto Automatic Start on Utility failure. 7 day exerciser
Off Stops unit. Power is removed. Control and charger still operate.
Manual Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Programmable start delay between 10-30 seconds Standard
Engine Start Sequence Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration)
Engine Warm-up 5 sec
Engine Cool -Down 1 min
Starter Lock -out Starter cannot re-engage until 5 sec after engine has stopped.
Smart Battery Charger Standard
Automatic Voltage Regulation with Over and Under Voltage Protection Standard
Automatic Low Oil Pressure Shutdown Standard
Overspeed Shutdown Standard, 72 Hz
High Temperature Shutdown Standard
Overcrank Protection Standard
Safety Fused Standard
Failure to Transfer Protection Standard
Low Battery Protection Standard
50 Event Run Log Standard
Future Set Capable Exerciser Standard
Incorrect Wiring Protection Standard
Internal Fault Protection Standard
Common External Fault Capability Standard
Governor Failure Protection Standard
22 • 27 • 32 • 38 • 48 kW
GENERAL®
available accessories
Model # Product Description
GOt.:.3-4
--.
1 Mobile Link"
Generac's Mobile Link allows you to check the status of your generator from
anywhere that you have access to an Internet connection from a PC or with
any smart device. You will even be notified when a change in the generator's
status occurs via e-mail or text message. Note: Harness ' i apter Kit required.
Available in the U.S. only.
G006478-0
Harness Adapter Kit
The Harness Adapter Kit is required to make 'ouid-cooled units compatible
with Mobile Link".
G005630-1 - 22, 27, 32 & 38 kW
G005632-1- 48 kW
Colo leather Kit
If the temperature regularly falls b• ow 32 °F (0 °„C), install a cot&weather kit •
to maintain optimal battery to : • rature. Kit corftists' otbattery yva rper with
thermostat built into the wr. -. '•....' •
G005616-0 - 22, 27, 32 & 38 kW
G007088-0 - 48 kW
Extreme Cold
Weather Kit
• •
Recommended wher• e temperature regularlyJlllnielow 32; ,(Q;Q) for •
extended periods s ime. For liquid cooled units on1�' • •
•••• •.•
. • . .
G005651-0
Base Plug Kit
As ; base .. ugs to the base of the generator to keep oui debris. .. • •
•
•• • • • • •.
G005703-0 - Bisque.
Paint Kit
..• . •. �• •
If t • ge • rator enclosure is scratched or damaged, it is import,4t'tp'
ch-up-t •-paint to protect from future corrosion. The paint kit includes the
necessary p.t to properly maintain or touch-up a generator enclosure.
G005656-0 - 22 & 27 kW
G005984-0 - 32 & 38 kW
G006205-0 - 48 kW
Scheduled
Maintenance . •
The Liquid -Cool: i Scheduled Maintenance Kits offer all the hardware
necessary to perfI m complete maintenance on Generac liquid -cooled
generators.
G006664-0
Local W. eless
Monito
Completely wireless an. s attery powered, Generac's wireless remote monitor
provides you with instant • atus information without ever leaving the house.
G006665-0
reless Remote
xtension Harness
H
Recommended for use with th• Wireless Remote on units up to 60 kW,
required for use on units 70 kW s greater.
G006873-0
Smart Management
Module (50 Amps)
Smart Management Modules are us • I in conjunction with the Automatic
Transfer Switch to increase its power nagement capabilities. It provides
additional power management flexibility it found in any other power
management system.
G006510-0
E-Stop
E-stop allows for immediate fuel shutoff and ge : ator shutdown in the event
of an emergency.
'rotectory 0 erie,
5 of 11
••.•
•
•
•
••••
•
•
•••
•••
••••
•
•
•
....
•
••••
"
1
RADIATOR/EXHAUST
DISCHARGE AIR
(BOTH SIDES)
REMOVE COVE
FOR ACCESS TO
RADIATOR FILL CAP
427
[18.8]
141
[5.6]
EXHAUST MUFFLE
ENCLOSED WITHIN
GENERATOR ENCLOSURE
RADIATOR/EXHAUST
DISCHARGE AIR
BATTERY 12
GRP 26
NEGATIVE GROUND
P/N: 077483
48
AIR INTAKE
(BOTH SIDES)
629.9 [24.8]
CENTER OF GRAVITY
(SEE NOTE 5)
TOP VIEW
1040
[40.9]
SERVICE ITEM
2.4L
OIL FILL CAP
EITHER SIDE
OIL DIP STICK
RIGHT SIDE
OIL FILTER
RIGHT SIDE
OIL DRAIN HOSE
LEFT SIDE
RADIATOR DRAIN
LEFT SIDE
COOLANT RECOVERY BOTTLE
LEFT SIDE
RADIATOR FILL CAP
ROOF TOP
AIR CLEANER ELEMENT
LEFT SIDE
SPARK PLUGS
LEFT SIDE
MUFFLER
SEE NOTE 11
DRIVE BELT
EITHER SIDE
FAN BELT
SEE NOTE 11
BATTERY
LEFT SIDE
REFERENCE OWNERS MANUAL
FOR PERIODIC REPLACEMENT
PART LISTINGS.
CIRCUIT BREAKE
SEE NOTE 3
980
,,. [38.6]
�✓"- OVERALL
HEIGHT
[1.9] FUEL LINE CONNECTION
3/4" NPT FEMALE COUPLING
LEFT SIDE VIEW
776 . [30.6]
OVERALL WIDTH
REAR VIEW
•••
•
•
•
•• •
• • .•• •
• •• • • • •• •
• • • • • • •
• ••• • •
• • • • •
• • • ••• •
• • • • • •
• • •• • • •• • • ••
• • • • • • • • • •
• • • • • • • 6 •
• • • • • • • • •
• NLli56: • ••• • •••
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1092 (43") WIDE X 1885 (74.2") LONG.
REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT FOR CONCRETE PAD GUIDELINES
• 2. AL(j,r UFF� NT F,pOM QN ,ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SEI VIC4NG•THIt UO{IT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
• APPLIDASLE.NFRA 3i AND NPPA 10 STANDARDS AS WELL AS ANY OTHER FEDERAL,
• STATE, AND LOCAL OOD!S. • • •
• 3. CONTROL P1>NNt. / CIR JIT REtKEti ] ORMATION:
• •SE! �ECIrICATION SSHEE OR WNeRS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF GENERATOR.
4. REMOVE THE REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUB -UP AREAS AS. FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTION INCLUDING TRANSFER SWITCH CONTROL WIRES.
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
7. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
8. MOUNTING BOLTS OR STUDS TO MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
9. MUST ALLOW FREE FLOW OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC
SHEET FOR MINIMUM AIR FLOW AND MAXIMUM RESTRICTION REQUIREMENTS.
10. GENERATOR MUST BE INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE
AND THAT DISCHARGE AIR FROM RADIATOR IS NOT RECIRCULATED.
11. EXHAUST MUFFLER AND FAN BELT ENCLOSED WITHIN GENERATOR ENCLOSURE,
REMOVE FRONT PANEL TO ACCESS.
REAR ENCLOSURE •
COVER PANEL
SEE NOTE 4
CUSTOMER ACCESS
ASSEMBLY, CONTROL
PANEL ACCESS,
BATTERY CHARGER
LOCATED WITHIN
SEE NOTE 4
WEIGHT DATA
ENGINE/KW
ENCLOSURE
MATERIAL
WEIGHT
GEKG [LBSJ NSET ONLY
WEIGHT
SHIKG )LBS]PPING KID
SHIPPING WEIGHT
KG [LBS]
2.4L 22KW
AL
410.5 [905]
30 [66]
440 [971)
2.4L 27KW
AL
426 [940]
30 [66]
456 [1006]
48
[1.9)
TYP
45
[1.8]
TYP
DIMENSIONS: MM [INCH]
r_ 631 [24.8]
DOOR TYP
1490 [58.7) TYP
1580 [62.2]
OVERALL LENGTH
RIGHT SIDE VIEW
VICE ACTION LATCH,
ONE PER DOOR,
ONE LIFT OFF
DOOR PER SIDE
OF GENERATOR
0
m
Z
m
�o-
n
n
22 &
0-
Z
0z
F w
wUoa
zz
ZO
O5
U
W W
Z
< Z
J Q
OU
>
w
00
z
Z Q 0
= Z
:) Q
CC = J
Q
0ce
W
c Z
Qa%
aw
7 Y
mw
I-.
Cm
CO
0x
? U
co
GENERAC®
installation layout
Drawing #0K8624-B (2 of 2)
cG
z
w
U V) w
j. IZ O m >
mJ K
N o O W!
mZ ,-
• •
•
• • •
Q •• • ••.• •
•
•
• ••.•
• • •
1 • •.•
•
• • • •
I •
Protector® • S Serie
i 0(11
••••
cr.
• • • •
o �• •• ••••
.(,
N
• 15 • •
• • t •
• ~ • • •� •
••••
m
• •f • • •
• • •7
• • 46 • . • • •
N • • ,
z • • •
• •
N
N
co
m
N
w
0
LEFT SIDE VIEW
• 1
RADIATOR/EXHAUST
DISCHARGE AIR ,
(BOTH SIDES)
n
167
[6.6]
535
[21.1]
2.5" O.D. EXHAUST
OUTLET
REMOVE COVE
FOR ACCESS TO
RADIATOR FILL CAP
RADIATOR/EXHAUST
DISCHARGE AIR
AIR INTAKE
(BOTH SIDES) _
TOP VIEW
768 [30.2]
ER OF GRAVITY
OTE 5
ATTERY 12V, GRP 26
NEGATIVE GROUND
P/N: 077483
EXHAUST MUFFLER
ENCLOSED WITHIN
GENERATOR ENCLOSURE
i- Ip A
.._
i 7'
R 0 '
+
r :-.4'.:, .
P
1
t al"
f
_p_i
1 r
K
4- lI
. ssa�
FUEL LINE CONNECTIO 50 [2.0]
3/4" NPT FEMALE COUPLING
LEFT SIDE VIEW
LIFTING PROVISIONS
(4 PLACES)
SEE NOTES 5, 7 AND
CENTER OF GRAVITY DIMENSIONS
1000 [39.4]
SERVICE ITEM
2.4L
OIL FILL CAP
EITHER SIDE
OIL DIP STICK
RIGHT SIDE
OIL FILTER
RIGHT SIDE
OIL DRAIN HOSE
RIGHT SIDE
RADIATOR DRAIN HOSE
LEFT SIDE
COOLANT RECOVERY BOTTLE
LEFT SIDE
RADIATOR FILL CAP ACCESS
AIR CLEANER ELEMENT
SPARK PLUGS
MUFFLER
DRIVE BELT
FAN BELT
BATTERY
ROOF TOP
RIGHT SIDE
LEFT SIDE
SEE NOTE 11
EITHER SIDE
SEE NOTE 11
LEFT SIDE
REFERENCE OWNERS MANUAL
FOR PERIODIC REPLACEMENT
PART LISTINGS.
CIRCUIT BREAKE
SEE NOTE 3
1171[46.1]
OVERALL
HEIGHT
Fe— 888 [35.0]—►I
OVERALL WIDTH
REAR VIEW
/ WEIGHT DATA
ENGINE/KW
ENCLOSURE
MATERIAL
WEIGHT
GENSET ONLY
KG [LBS]
WEIGHT
SHIPPING SKID
KG [LBS]
SHIPPING WEIGHT
KG [LBS]
2.4L 32KW
AL
558 [1225]
44 [98]
600 (1323]
2.4L 38KW
AL
580 (1235]
44 [98]
605 [1333]
••• • •
• •• ••
• • • •
• •• •
•
•
••• •
• ••• • •
•• • • •
•• ••
• • •• •• • • •
••• • •• • •
• . •• •• ••
• • • • • • •
•
• • •
• • •• • •
• • • •
• • • • •
• • •
•
•
• NOTES•
• •
•
••
• •
•
••
• •
• • ••
• • •
• • •
• • •
• • • •
1. MINIMUM RECOMMENDED CONCRETE PAD
SIZE: 1194 (47") WIDE X 5 (88.8") LONG.
REFERENCE INSTALLATION GUIDE SUP_PJ.IED WITH UNIT FOR CON ETE PAD
tAN SERV INC. TA' ROOM L L.AL INS.I LLED IN ACC DOR F •WITH CURRER NTEELINES.
APll1 SERVICINb.[T�HIS NI I�ID
•AQQTE,ggAQQNgPPLICAEL LCC�����EEA �CO GG7 E��IIF T • ARDS AS WELL AS Y OTHER FEDERAL,
S- -SEE SPE ACATI NL ISHEET O OWNERSrMANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSE - Y DOOR ON REAR OF GENERATOR.
4. REMOVE THE REAR ENCLOSURE COVER PANEL T• ACCESS
THE STUB -UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC AAD LEAD CONDUIT CONNECTION, NEUTRAL
CONNECTION, AND BATTERY CHARGER 12OLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTION INCLUDING - ' NSFER SWITCH CONTROL WIRES.
5. CENTER OF GRAVITY AND WEIGHT M • HANGE DUE TO UNIT OPTIONS.
6. BOTTOM OF GENERATOR SET MUST ENCLOSED TO PREVENT PEST INTRUSION AND
RECIRCULATION OF DISCHARGE A - AND/OR IMPROPER COOLING AIR FLOW.
7. REFERENCE OWNERS MANUA ' •R LIFTING WARNINGS.
8. MOUNTING BOLTS OR STUD 0 MOUNTING SURFACE SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TOR . SPECS)
9. MUST ALLOW FREE FL• OF INTAKE AIR, DISCHARGE AIR AND EXHAUST. SEE SPEC
SHEET FOR MINIMUM : - FLOW AND MAXIMUM RESTRICTION REQUIREMENTS.
10. GENERATOR MU :E INSTALLED SUCH THAT FRESH COOLING AIR IS AVAILABLE
AND THAT DISC -GE AIR FROM RADIATOR IS NOT RECIRCULATED.
11. EXHAUST FLER AND FAN BELT ARE ENCLOSED WITHIN GENERATOR ENCLOSURE,
REMOVE F • T PANEL TO ACCESS.
REAR ENCLOSURE
COVER PANEL
SEE NOTE 4
USTOMER ACCESS
ASSEMBLY, CONTROL
PANEL ACCESS,
BATTERY CHARGER
LOCATED WITHIN
SEE NOTE 4
47
[1.8]
TYP
DIMENSIONS: MM [INCH]
-0-- 759 [29.9]
DOOR TYP
1857 [73.1] TYP
1950 [76.8]
OVERALL LENGTH
RIGHT SIDE VIEW
VICE ACTION LATCH,
ONE PER DOOR,
ONE LIFT OFF
DOOR PER SIDE
OF GENERATOR
58
[2.3]
TYP
CA)
co
MIME
rF
0•
PLAN OF - SURVEY
SCALE 1" =30'
ry
� 10r fv
401 fro 1 LL(
1,0" 141114 i
'L0. j'P
4L4
40// Wick •
IQ' fir°1/1 PVv
Iw1 'Oiionotow,Notiv-6,-0
4tuw— S l
�2
W J/I.M SP/tF
tfc
F"ODUL
p/eG
r 8 v
P4 Le
F,
45PHg[r
U.E. 93.5(5
/2.�.vg,
Afro/ea-)
POOL
•
n nI
sr6P3
pr1A[r
rl9 68"_
f/z5'4,erwAY
/3,00'
Fovni®rp/� -
1.0., Cuo cep)
.
• • •
• •
• •
• ..
.. •
3z 3'PooL pops
En- 3'X3'pooz
nou NOG
(tdlJtrs)
A5P//AC r
w00C
`Ed10E
.
•••
.
.
4r41rV 1/uu
rouiJo !a pipe
✓ [uo c_.4
h
POLE`W
-7:' 1_ vi r T
-3/q 1, icb Li i pz Ikuri, il,tteA & .9 ILK-M,a7n
3 b i/ p 20 pE 7y A0o1Es5.
f �3I`��� �i'� L'`� l905N. E. 92od iT
vi2N/A,u/ S:a02S5, F.L .33188
ADRADIAL ENC.ENCROACHMENT RAN...RIGHT OF WAY... FIP...FOUND IRON PIPE OH,OVER HEAD • WMWATER METERCANTER TTANGENT C.BCATCH BASIN MHMANHOLE CLFCHAIN.INK FENCE WFyV000
Le�D Ib 2 ,ems
.
.
...ARC DISTANCE A/C...AIR CONDmONING CBS...CONCRETE BLOCK STRUCTURE O.U.L...OVERHEAD UTILITY UNE CL..CLEAR CjL..CENT�R LINE
C.H-.-CHORD
STANCE P/L...PROPERTY LINE CONC...CONCRETE F.H. FIRE HYDRANT UP...UTILTTY POLE R...RADIUS U.E...UTIUTY EASEMENT
..CENTRAL ANGLE R.:.RADIUS PL....P .... .._ ... ... .._. FENCE
4
JOB :17-72731
LOCATION SKETCH 1 SCALE
—taor -CO
— am...
a.1�. 93ao ST
4
1 S.o �
l /
i !
1/1/1
Y's;
. . .
.. .
•
•
•
. •
....
04100
....
. . • .
.. .. ....
•
•
•
LEGAL :Lot A,COLDER GATE PARK ADDITION,according to the Ptat:thereof es recorded
in Plat Book 6,Page 130 of the Public Records of Miami -Dade Connty,Florida.- . •
. .
.
GENERAL NOTES
1) OWNERSHIP 1S SUBJECT TO OPINION OF TITLE. s
2) EXAMINATION OF THE ABSTRACT O: TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY, AFFECTING
THIS PROPERTY.
3) (2.22) DENOTES THOSE ELEVATIONS REFERRED TO NIA DATUM.
4) LOCATION AND IDENTIFICATION OF UTILITIES ON ANDIOR ADJACENT TO THE PROPERTY WERE NOT SECURED AS SUCH
INFORMATION WAS NOT REQUESTED.
5) THIS PROPERTY IS WITHIN THE LIMITS OF THE FLOOD ZONE X
6) NO UNDERGROUND LOCATIONS WERE DONE BY THIS COMPANY.
CER DT D TO: Centurion Title Services,LLC,WFG National Title DATE:
Insurance Company,Garrett Schaefer and Svetlana A. Lioutikoff June 27,2017
VE1ls,Fargo Bank,N.A.,ISAOA
APPLICABLE ZONING, UNDERGROUND, ZONING'AND BUILDING SET BACKS, MUST BE CHECKED BY OWNER,
ARCHITECT OR BUILDER BEFORE DESIGN OR CONSTRUCTION BEGINS ON THUS PROPERTY.
1 HEREBY CERTIFY: That theattached Plan of Survey of the above described propgrty is true
and correct to the best of my knowledge, information and belief, as recently/ surveyed a11d platted
under my direction, also that there"are not above -ground encroachments other than tho¢e shown.
This survey meets the minimum technical standards set forth by the Florida BoarJ of Land Surveyors
pursuant to Chapter 61G17-5, Florida Administrative Code, Section 472-027, Florida Statues.
SURVEYING, INC
LB. NO. 3333
6187 NW 167m STREET, His
MIAMI, FLORIDA 33015
3051512-4940
D. Alonso
i5sional Land Surveyor
Certificate I4p. 3590
- State of Florida
THIS IS A BOUNDARY SURVEY
•
NOT VALID UNLESS SEALED WITH AN EMBOSSED SURVEYOR'S3
Job Address
Job Description:
Contractor Information
905 NE 92 St.
Miami Shores, FL. 33138
Pour Concrete Pad for
27kw NG fired Generator
Pad weight = 3,800 Ibs
All Quality Electric
14500 NW 16 Ct
Miami, FI. 33167
305-968-7832
Owner Information
Residence of
Garrett Schaeffer
Residence of Garrett Schaeffer, 905 NE 92 St., Miam' Shores, FL. 33138
40" Wide
70" Long
0 0
0 0
Concrete Pad Notes:
✓ #5 Reinforcing Rebar
✓ Sakrete 3000 PSI Cement
✓ Weed block material applied prior to pour
✓ Generator mounted to pad with'/2" diameter x 4.5" long
Redhead concrete expansion bolts
✓ Pad weight after pour will be 3,800 Ibs.
6/11/2018
...... .
•
STRUCTUi REV
APPROVED
.
.. ... .. • ....
• ... . ... . ...
••
•
•
•
. • . . • . .. • • •
• . .. . . .. • . ••
• • .
... . • • . ... . .
• . •. •. •• . . •
.
• . . ... . • .
• . . • . . •. •
.. •
• •• .• • • • .. •.
... • • • ... • •
W
10" High
PLAN OF SURVEY
SCALE 1" =30'
G�ditW SPItl
04ASPW4LT
en?
10' fvv
st
,- (1; from Kul
— loll k' i k p44i .
101fLei
,fc/fmck —01 :4-
fireti la*
.p oftmkAl `N
D 2,
1161 (At.. . -)ItC610,0;f1 -' lc
�J v
Cvvinciolof`boviciV-L--T)
I
3
2 22 �,�,,,,_ �e t c
f IL"C�
F-aUL'O
spec
25'
POLE
F, H,
•
�
DI I eo
55/
W00' FEMCE
0-40/64
45014zr
E. 93Jts/,
1zs'
18,8'
` '�► POOL.
35.7'
15rO kY
1 Ari
/6.70 t, ,Q
' i1 ''� a? 0
6'=r!rsiU: I
.11
5ffo5
45 paiAL ,r
21-R5 '',etwAY
• •
• • •
•• •
€3-3'X3.POOL
eou t2Ot
4'r8•A/C
(Z fJbl! as)
w000
6EicE
84
7
1 KO w° yz pipe
Cue cis a0
`POLE t'41 ' L
AsP/vaC T
h
•
• ••
•••
•
••••
• •
• • • •
FOWL,
• •
•
4 •
e.
'•(s14W1i 4 4rt
•
••••
• • • •
•.• •••
44,• •••
3z 3'Pdoc u4.0s • b
•
...�
•• IN
J
• • •PL.•• •
•
• •
•
•
•
• •
• •
H
Nor. Szfi- T /`''F.,,wel.--t/ !-;
P20p ,?T/ADQ/I�sS.
905 N. E. 9Z /J0
.33/68
A....ARC DISTANCE AIC...AIR CONDmONING CBS...CONCRETE BLOCK STRUCTURE O.U.L...OVERHEAD UTIUTY UNE CL...CLEAR CjL_..CENTER UNE
RAD...RADIAL ENC..ENCROACHMENT RJW...RIGHT OF WAY... FIP...FOUND IRON PIPE - O.H..,OVER HEAD - W.M....WATER METER c.$....CHORD
DISTANCE P/L...PROPERTY UNE CONC...CONCRETE F.H. FIRE HYDRANT UP...UTWTY POLE R.RADIUS U.E._.UTILITY EASEMENT
A...CENTRAL ANGLE R...RADIUS- PL.....PLANTER T..-TANGENT C.B.._CATCH BASIN MH..._MANHOLE CLF...CHAIN LINK FENCE W.F.....}NOOD FENCE