Loading...
MC-16-153Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address I4sue Date: 1 Permit NO. MC-1-16-1'53 Permit Type: -Mechanical,- Residential Work Classification:A/C Replacement Permit Status: APPROVED 0/2016 Expiration: 05/29/2017 Parcel Number Applicant 1201 NE 94 Street Miami Shores, FL 33138- 1132050100010 Block: Lot: BERNARD LEE Owner Information Address Phone Cell BERNARD LEE 1201 NE 94 Street MIAMI SHORES FL 33138- (954)673-6513 1201 NE 94 Street MIAMI SHORES FL 33138- Contractor(s) DEDICATED COOLING LLC Phone (786)326-0911 Cell Phone Valuation: Total Sq Feet: $ 4,500.00 0 Tons: Additional Info: INSTALL 3 MINI SPLIT SYSTEMS WITH 2 Classification: Residential Approved: In Review Comments: Date Denied: Scanning: 3 Date Approved:: In Review Type of Work: Fees Due CCF DBPR Fee DCA Fee Education Surcharge Notary Fee Permit Fee Scanning Fee Technology Fee Total: -) Amount $3.00 $3.15 $3.15 $1.00 $5.00 $210.00 $9.00 $4.00 $238.30 Pay Date Pay Type Invoice # MC-1-16-58391 01/20/2016 Credit Card 11/30/2016 Credit Card Amt Paid Amt Due $ 50.00 $ 188.30 $ 188.30 $ 0.00 Available Inspections: Review Electrical Review Electrical Review Electrical Review Mechanical Review Mechanical In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required forELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. .-s OWNERS AFFIDAVI : I certii . all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction : -- rmore, I authorize the above -named contractor to do the work stated. Authorized natur::Owner / Applicant / Contractor / Agent Building Department Copy November 30, 2016 Date November 30, 2016 1 V\\`").- Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION JAN 20 2016 ' STD FBC20H Master Permit No. > Me ! G ! 53 Sub Permit No. ❑ EXTENSION ❑PLUMBING giMECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF CONTRACTOR JOB ADDRESS: VA A- City: Miami Shores County: Miami Dade ❑ CANCELLATION ❑ RENEWAL ❑ SHOP DRAWINGS Zip: ) 1 lb Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: OWNER: Name (Fee Simple Titleholder): Address: rat\ Nt ri'A Jt City: AA, O p 5k0tt) Construction Type: Flood Zone: BFE: FFE: 2-gtnnrA La State: FL Phone#: 673- CS13 Zip: ? 3 / 3 j Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: eA, [a\ CA ( Dot Ll, C Phone#: Address: 39 134 NV1 (1 +a,( City: 1-1Atteklf1 Qualifier Name: Luic State: r L RE BY: Phone#: State Certification or Registration #: Certificate of Competency #: DESIGNER: Architect/Engineer: , Phone#: -7)4, 3Li6 NS?) Zip: 3 3 (212 Address: CAc.i } 17011 Value of Work for this Permit: $ u - j WV % o IM. Square/Linear Footage of Work: 6“) Type of Work: ❑ Addition n n New ' Repair/Replace n Demolition City: State: Zip: Description of Work: ) h5'r•a\\ 3 mini e>►is A'1 i• r(i j': SiSVCw,c wr��, �— .Lvrt�rnSorI . • •.'.,,b,,r..-,.r.„. Specify color of color thru tile: ^� 1 Submittal Fee $ SO •W Permit Fee $ — V 0 CCF $ J: Scanning Fee $ Radon Fee $ DBPR $ Technology Fee $ Training/Education Fee $ Structural Reviews $ (Revised02/24/2014) So 2(5`11 CO/CC $, Notary $ 5 W Double Fee $ Bond $ 3®C`1l7 TOTAL FEE NOW DUE $ ) Seal: 4, Notary Public State of Florida Joanna M Feliciano c` My Commission FF 082753 ( Apr Expires 01 /12/2018 APPROVED BY Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City + State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT The foregoing instru ent was acknowledged before me this 13 day of Vary , 20 /lc , by who is personally known to rpL as me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sigh Signature• - CONTRACTOR The foregoing instrument was acknowledged before me this Osz, day of (l nn\ , 20 6 , by ' �.JJ(S f\ .(G , who is personally known to me or who has produced �� 1�1�►��as (identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: 12 ns Examiner NU A A.uv-A -, Notary :,,,Jtielie State of Florida Sindia Aivarez "' My Commission FF 156750 Expires 09/03/2018 * * * * *,* * ** Zoning (Revised02/24/2014) Structural Review Clerk AN 2�0,2016 rin r"imili Shores AP,.: OVPD ZO6,,!4 � xx DEPT; 16164, �k I 00 5-10b v►no.mkt.), LAN oho �vQ nee C(1n%CASaskt?. fow vt,tAlt, 10^00gh vva\\ �o 9 RQ_ib—F se' 4 Villige DATE BY BLDG DEPT .... . . • • • •••• • • • co'v uttoC • • • •_••••• •••• •••• • . •• •• • • • • • • • • • •• •• • Eon SUB.n i (; ( )MI'! IANCE W(TH ALL FEDERAL STATE n' ,I ) ' • " ; Y (?l 11 I=S AHD RTGUI_ATIONS yctratRA vi, Pete Mronll shotto RC 33(3b. • • •• • • • • • •••• • • •••• • • • •••• • •• • • • • • • • •• n o %- -r- •• › ...--,Y r- � 5,- 6' t7m rak 0 9 cto 3 -2 — 5— _v '-/( - rol„?,/-274;ee s 3 9' 0 Ca . • . • • .. • . ••. • • . •••• • . . . . • . . • •• •••• •• • • ••• • • ▪ •••• •••• • • • .... •• .• • • • • • • •• • • • • • • •••• • • • • • • • • • •• • 02 7sc7.2 Job Name/Location: Date: PO Nd.: Architect: For: File ❑r Resubmit r Approval ® Other GC: Engr: Mech: Rep: (Company) (Project Manager) LA090HVP Art CoolTM Gallery Single Zone Inverter Outdoor Unit (ODU) - LAU09OHVP Indoor Unit (IDU) - LAN090HVP Performance: Cooling: Capacity (Btu/h) SEER EER 9,000 16 12.5 SEER - Seasonal Energy Efficiency Ratio EER - Energy Efficiency Ratio Heating: Capacity (Btu/h) HSPF 10,800 8.2 HSPF - Heating Seasonal Performance Factor Cooling Nominal Test Conditions: Heating Nominal Test Conditions: Indoor: 80'F DB/67'F WB Indoor: 70'F DB/60'F WB Outdoor: 95'F DB/75'F WB Electrical: Outdoor Unit: Outdoor: 47•F DB/43•F WB Power Supply (VI/Hz/0) MCA (A) MOP (A) Rated Amps (A) Compressor (A) Fan Motor (A) 208-230/60/1 10 15 8.1 7.6 0.25 MOP - Maximum Overcurrent Protection MCA - Minimum Circuit Ampacity Indoor Unit: Power Supply (VI/Hz/0) Cooling Power Input (kW) Heating Power Input (kW) 208-230/60/1 0.72 0.85 Piping: Liquid Line (in, OD) Vapor Line (in, OD) Additional Refrigerant (oz/ft) Max Pipe Length (ft)2 Piping Length (no add'I refrigerant, ft) Max Elevation (ft) 1/4 3/8 0.22 49.2 24.6 22.9 Controls Features: •24-Hour on/off timer •Auto changeover •Auto restart •Auto sleep mode •Built-in low ambient standard down to 14°F (cooling mode) Optional Accessories: ea •Chaos Wind •Customizable art panel *Dehumidifying mode • Fan mode •Jet Cool/Jet Heat • Self-cleaning indoor coil •Three-way cooling LG Programmable Thermostat - PREMTB1OU Simple Controller with Mode (Black) - PQRCVCLOQ Ei Dry Contact for Third Party Thermostat - PQDSBNGCM1 For continual product development, LG reserves the right to change specifications without notice. ® LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Lite's Good" is a registered trademark of LG Corp. /www.Ighvac.com 0 LG Life's Good Operating Range: Outdoor Unit: • • • •.•• • •• • • • • • • • • • • • • • � • Cooling (°F DB) Heating (°F WB) • • • • • •• • • • • • • • • • : 14 111 14-7`1 • Indoor Unit: Cooling (°F DB) Heating (°F DB) 64-90 61-86 Unit Data: Refrigerant Type Refrigerant Control Refrigerant Charge (Ibs) ODU Sound Pressure Max ±3 dB(A)3 Indoor Sound Pressure (H/M/L) ±3 dB(A)3 ODU Net Weight (lbs) ODU Shipping Weight (lbs) IDU Net Weight (Ibs) IDU Shipping Weight (lbs) Heat Exchanger Coating R410A EEV 2.21 45 42/36/32 78 82 31 34 GoldFin'" Fan: ODU Type IDU Type Fan Speeds (Fan/Cooling/Heating) Quanity (ODU + IDU) Motor/Drive ODU Max Air Flow Rate (CFM) IDU Air Flow H/M/L (CFM) Dehumidification (pts/hr) Propeller Turbo 4/5/5 (1 + 1) Controlled/Direct 1,165 335/311/247 2.54 Notes: 1.Acceptable operating voltage: 187V-253V. 2.Piping lengths are equivalent. 3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 4.AII communication cable to be minimum 18 AWG, 4-conductor, stranded, shielded and must comply with applicable local and national code. 5.See Engineering Manual for sensible and latent capacities. 6.Power wiring cable size must comply with the applicable local and national code. 7.The indoor unit comes with a dry helium charge. 8.This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line and a 0 ft level difference between outdoor and indoor units. 9.Must follow installation instructions in the applicable LG Installation manual. u• Intertek Inverter ENERGY STAR Brushless Digitally an it T IFIT E tit ,,., t�X www atsr)directory 0t A1AiSta4clard 2101240 raruk aon r. . sO l•:ram b6teaNL% Uffer40,M,T aabms%axlit+,4a*r++Kas'x,rxmw.treillysMir' VRF-SB-AK-001-US 013D23 Page 1 of 2 Job Name/Location: LA090HVP Art CooITM Gallery Single Zone Inverter Outdoor Unit (ODU) - LAU090HVP Indoor Unit (IDU) - LAN090HVP Outdoor Unit 30.5/16 Indoor Unit Unit : inch Tag #: LG Date: Life's Good PO No.: err • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •• • • • • • •• •• • • • • Item No. cafe NaIi • •... Remarks • 1 Air Distdla•ge&dile •••• 2 Gas Pioe•C•n/J{tiop Port • • 3 Liow d P:Pe Caaon Port . • •--••• 4 Control gee • • 5 Earth Sc}ew • • a. • • • Item No. Part Name Remarks 1 Front penal 2 Display a Si receivor 3 Air discharge gripe 4 Krtbckov 1 hb l e.. For pipe and cable For continual product development, LG reserves the right to change specifications without notice. ® LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.Ighvac.com VRF-SB-AK-001-US 013D23 Page 2 of 2 Job Name/Location: Tag #: Date: PO NO: Architect: [For: ❑cu File ❑ Resubmit Li Approval ® Other GC: Engr: Mech: Rep: (Company) (Project Manager) LMU18CHV Multi F Inverter Heat Pump Outdoor Unit i { Performance: Nominal Cooling Capacity (Btu/h) Nominal Heating Capacity (Btu/h) Cooling Power Input (kW) Heating Power Input (kW) 15,600 17,000 1.31 2.04 Cooling Nominal Test Conditions: Indoor: 80°F DB/67•F WB Outdoor: 95'F DB/75•F WB Electrical: Heating Nominal Test Conditions: Indoor: 70'F DB/607 WB Outdoor: 477 DB/43°F WB Power Supply (V/Hz/() MOP (A) MCA (A) Cooling Rated Amps (A) Heating Rated Amps (A) Compressor (A) Fan Motor (A) 208-230/60/11 20 13.3 11.09 11.09 8.9 0.59 MOP - Maximum Overcurrent Protection MCA - Minimum Circuit Ampacity Piping: Refrigerant Charge (Ibs) Liquid Line (in, OD) Vapor Line (in, OD) Max Total Piping' (ft) Max ODU to IDU Piping (ft) Piping Length (no add"I refrigerant, ft) Max Elevation between ODU and IDU (ft) Max Elevation between IDU and IDU (ft) 3.97 1/4 x 2 3/8 x 2 164 82 49.2 49.2 24.6 ODU - Outdoor Unit IDU - Indoor Unit Controls Features: •Auto operation •Auto restart operation •Defrost/Deicing •Inverter (variable speed compressor) •Built-in low ambient standard down to 14F •Restart delay (3-minutes) •Self diagnosis •Soft start Optional Accessories: PI-485 Integration Board - PMNFP14A0 Ei AC Smart Premium - PQCSW421E0A E AC Ez - PQCSZ250S0 t`i Power Distribution Indicator - PQNUD1S00 For a complete list of available accessories, contact your LG representative. LG Life's Good Operating Range: • • •• •• • • •• • • • • • • • • • • • • • • Cooling (°F DB) • • • Heating (°F WB) • ••• • •• • • • • • INVLRTCR • • ••': • • • • `...' • ••• •• • • •..;ar• • •• • • 14138. • -4-64 •• • Unit Data: •••• • • • •• • • Refrigerant Type Refrigerant Control Sound Pressure' (Cool/Heat) ±3 dB(A) Net Unit Weight (Ibs) Shipping Weight (Ibs) Heat Exchanger Coating Min Number of Indoor Units Max Number of Indoor Units R410A EEV 49/52 100 108 GoldFinr" 2 2 Compressor: Quantity Type Oil/Type Fan: 1 Twin Rotary FVC68D Type Quantity Fan Motor/Drive Airflow Rate (CFM) Propeller 1 Brushless Digitally Controlled/Direct 1766 Notes: 1.Acceptable operating voltage: 187V-253V. 2.Piping lengths are equivalent. 3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 4.AII power/communication cable to be minimum 18 AWG, 4-conductor, stranded, shielded and must comply with applicable local and national code. 5.Power wiring cable size must comply with the applicable local and national code. 6.See Engineering Manual for sensible and latent capacities. 7.Power wiring cable size must comply with the applicable local and national code. 8.Thls data is rated 0 ft above sea level, with 24.6 ft of refrigerant line and a 0 ft level difference between outdoor and indoor units. All capacities are net with a combination ratio between 95 — 105%. 9.Refer to the Engineering Product Data Book for combination capacity tables. 10.Must follow Installation instructions in the applicable LG installation manual. cOus Intertek Inverter ne* :CERTIFIED ,TLbsu 7Xjx�'riww.eh�Idlraeloi7,or9 For continual product developmer t, LG reserves the right to change specifications without notice. ®LG Electronics U.S.A., Inc., Englewood Cliffs, Ni. All rights reserved. "LG Life's Good" Is a registered trademark of LG Corp. /www.lghvac.com. SB-MultiF-LMU18CHV-08-14 Page 1 of 2 rob Name/Location: LMUISCHV Multi F Inverter Heat Pump Outdoor Unit 31132 34-1/4 • L.—.t Lml 13-13/18 No. Part Name 1 Air discharge grille 2 Gas pipe connection 3 Liquid pipe connection 4 Power & transmission connection 5 Main service valve(Gas) 6 Main service valve(Liquid) 2-3/18 LGDate: Life's Good p0 No.: Unit: WA' : 6) Centerof•avity •.••-• . • •. • • ••.• • • • � • • • • •••• •• . • • • • • • • • • • •• .• • •.•. . • •.••. .•.• • • • •• • • • • • • • • • •. • • ••.. • . • • • • • •I • • For continual product development, LG reserves the right to change specifications without notice. ®LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.lghvac.com. SB-MultlF•LMU18CHV-08.14 Page 2 of 2 Job Name/Location: Tag #: Date: PO No.: Architect: For: E File ® Resubmit Approval 0 Other GC: Engr: Mech: Rep: (Company) (Project Manager) LANO9OHSV4 Multi F Art CooITM Mirror - Wall Mount 9,000 Btu/h Indoor Unit Performance: Nominal Cooling Capacity (Btu/h) Nominal Heating Capacity (Btu/h) 9,000 10,400 Cooling Nominal Test Conditions: Indoor: 80'F DB/67'F WB Outdoor: 95'F DB/75'F WB Electrical: Heating Nominal Test Conditions: Indoor: 70'F DB/60°F WB Outdoor: 47'F DB/43°F WB Power Supply (Vt/Hz/O) Rated Amps (A) 208-230/60/1 0.20 Pipe Connections: Liquid (in, OD) Vapor (in, OD) Drain OD, ID (in) Temperature Sensor 1/4 3/8 13/16, 5/8 Thermistor Controls Features: •4-Way auto swing •24-Hour on/off timer 'Auto operation •Auto restart •Chaos wind •Inverter (variable speed fan) •Jet Cool •3M HAF filter •Self-cleaning indoor coil •Sleep mode •Condensate sensor connection *Group control •Smart AC module *Compatible with Single Zone HSV4 ODU Included Accessories: •Wireless Remote Controller - AKB73835317 Optional Accessories: • LG Programmable Thermostat - PREMTB1OU E Simple Controller with Mode (Black) - PQRCVCLOQ E Simple Controller with Mode (White) - PQRCVCLOQW l] Simple Controller without Mode (Black) PQRCHCAOQ ® Simple Controller without Mode (White) - PQRCHCAOQW I1 AC Smart IV - PACS4B000 ® ACP IV-PACP4B000 g LonWorks® Gateway - PLNWKB100 ACP IV BACnet6 Gateway - PQNFB17C1 Dry Contact Unit (1 contact, 24 VAC external power) - PQDSB1 E Dry Contact Unit (2 input, power from indoor unit) - PQDSBC • Dry Contacts for third party thermostat - PQDSBNGCM1 or PDRYCB300 For a complete list of available accessories, contact your LG representative. LG Life's Good Entering Mixed Air: Cooling (°F WB) Heating (°F DB) Unit Data: eau ra)C.D49 trS1E7JV46123114 •u • • • • • • • • • • • • • 57-77 59-81 • • • •• • • • • • Refrigerant Type • Refrigerant Control • • • • • • • Sound Pressure2 H/M/L'(t311B(A)) • • • • Net Unit Weight (Ibs) ..• ..• Shipping Weight (Ibs) • • • • • • • • • • • • • • •• •�3 • • • • • • • •• • Fan: • • • • • • • • • • • • • • • • • Type Quantity Motor/Drive Cross Flow 1 Brushless Digitally Controlled/Direct Airflow Rate H/M/L (CFM) 247/230/212 Notes: 1Acceptable operating voltage: 187V - 253V. 2.Sound Pressure levels are tested in an anechoic chamber under 150 Standard 1996. 3.See Engineering Manual for sensible and latent capacities. 4.AIl power/communication cable to be minimum 18 AWG, 4-conductor, stranded, shielded and must comply with applicable local and national code. 5.Power wiring cable size must comply with the applicable local and national code. 6.This unit comes with a dry helium charge. 7.Corresponding refrigerant piping length is in accordance with standard length of each outdoor unit and the level difference is 0 ft. All capacities are net with a combination ratio between 95 —105% 8.Must follow Installation Instructions In the applicable LG Installation manual. Inverter c�llra Intertek ,CERTIFIED. Uniti4Small AC AV. fAHRt_Standard 210/240U n CwWhieK71`. on r n9m pnr mown ssslem b Need vet AWL; 6+iK§�+w.iJ+L9•e:t r:.+�+.it�a'R—;f For continual product development, LG reserves the right to change specifications without notice. ® LG Electronics U.SA., Inc., Englewood Cliffs, N.I. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.Ighvac.com SB-MultiF ArtCoolMirror-LANO9OHSV4-02-15 Page 1 of 2 • Job Name/Location: LAN090HSV4 Multi F Art CooITM Mirror - Wall Mount 9,000 Btu/h Indoor Unit a Jlt v3 94 s g. cr 7 I(I ktt O' A. CZN � 3 Z 0 Installation Plate Knockout hole Return Air Grille Display & Signal Receiver Front Panel Part Name T O to n' tD so n a m g co XI W 3 Jn LG Tag #: Date: Life's Good PO No.: 2.3/S • ... ..... .. • . • • •••• ••••UP • •• •C ••••4-. • • • • • • •. ..• • • • • • • • • • • • • • For continual product development, LG reserves the right to change specifications without notice. 0 LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.Ighvac.com SB-MultiF_ArtCoolMirror-LANO9OHSV4-02-15 Page 2 of 2 lob Name/Location: Date: PO No.: Architect: Engr: Rep: For: 0 File 0 Resubmit Mech: Tag #: Approval E Other (Company) (Project Manager) LMDN095HV Flex Multi Ceiling Concealed Duct 9,000 Btu/h Indoor Unit Performance: Nominal Capacity (Btu/h) 9,000 Cooling Nominal Test Conditions: Indoor: 80'F DB/67'F WB Outdoor: 95°F DB/757 W8 Electrical: Heating Nominal Test Conditions: Indoor: 70°F DB/60'F WB Outdoor: 47°F DB/43°F WB Power Supply (V1/Hz/0) Rated Amps (A) 208-230/60/1 0.25 Piping: Liquid Line (in, OD) Vapor Line (in, OD) Drain OD, ID (in) Temperature Sensor Max Length Each Pipe (ft) Max Elevation between ODU and IDU (ft) Max Elevation between IDU and IDU (ft) 1/4 3/8 1-1/4, 1 Thermistor 82 49.2 24.6 Features: • 2 Thermistor control • Auto operation •Auto restart *Control lock function *Internal Condensate Pump *Inverter (variable speed fan) Included Accessories: *Simple Controller with Mode (White) - PQRCVCLOQW Optional Accessories (sold separately) 7-Day Programmable Controller (Black) - PQRCVSLO • 7-Day Programmable Controller (White) - PQRCVSLOQW • Simple Controller with Mode (Black) - PQRCVCLOQ Simple Controller without Mode (Black) PQRCHCAOQ t» Simple Controller without Mode (White) - PQRCHCAOQW 0 AC Smart II - PQCSW320A1E ACP without Digital I/O - PQCPA11A03 El ACP with Digital I/O - PQCPB11A0E ✓ LonWorks Gateway - PQNFB16A1 • BACnet Gateway - PQNFB17B0 i.. AC Ez - PQCSZ25OS0 Dry Contact Unit Dry Contact Unit (1 contact, 24 VAC external power) - PQDSB1 O Dry Contact Unit Dry Contact Unit (2 input, power from indoor unit) - PQDSBC EJ Dry Contact for third party thermostat - PQDSBNGCM1 PQRCVCLOQW LG Operating Range: Cooling Max ("F WB) Heating Min ("F DB) • • ••.,i,, • • • • • • 76 59 Unit Data: • • • •• • • • Refrigerant Type Refrigerant Control • • • • Sound Pressure H/M/L•(±3dd(A)) Primary Filter • • •• •• • Net Unit Weight (Ibs) • • • Shipping Weight (Ibs) • • Communication Cable $N .itAWG) • •R410A• • • • • EEw ••• •• • . • •••• 31/iG/•2b • • lgellable PM -filter • • • •••• • • • 46 •• ••51• • • • Fan: •• • Type Quantity Motor/Drive Sirocco 3 Brushless Digitally Controlled/Direct Airflow Rate H/M/L (CFM) 300/265/229 Max External Static Pressure (in wg) 0.157 Dehumidification Rate (pts/h) 2.1 Standard Features: •Limited Warranty with LG Certified Installation •Limited Two Year Functional Parts Warranty Notes: 1.Acceptable operating voltage: 187V-253V. 2.See Engineering Manual for sensible and latent capacities. 3.Sound Pressure levels are tested In an anechoic chamber under ISO Standard 1996. 4.AII communication cable to be minimum 18 American wire gage (AWG), 2-conductor, stranded, shielded and must comply with applicable local and national code. 5.Power wiring cable size must comply with the applicable local and national code. 6.This unit comes with a dry helium charge. 7.This data Is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0 ft level difference between outdoor and Indoor units. All capacities are net with a combination ratio between 95 — 105%. 8.Must follow installation Instructions In the applicable LG installation manual. Inverter e Intertek am r ICERTIFIED:: www.ahr)dlrectory:org ttlnitary.SmaJIAC ANRI Stanford 210P240 C at$ a Oat *ban the aepids system is kW r9aAitP1. For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" Is a registered trademark of LG Corp. /www.lghvac.com DFS-SB-AD-008-US 012M17 Page 1 of 2 Job Name/Location: r LMDN095HV Flex Multi Ceiling Concealed Duct c 9,000 Btu/h Indoor Unit 217/32 2 3/8 4111 ton a • • • • • • • • 15 3/32 225/8 .................... _............... Tag #: LGDate: PO No.: UJ CT ut A W N Z 5) Power supply connection uotpauumadid uiwd r- Gas pipe connection Air discharge flange Air suction flange Part Name .3' c E v' ro 0 0 9 n C. 9 ro 3 ck v, • • • • • • • • • •••• • • •• V•••• • • • •• • • • • • • • • • • • • For continual product development, LG reserves the right to change specifications without notice. LG Electronics U.S.A., Inc., Englewood Cliffs, N1. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp. /www.Ighvac.com DFS-SB-AD-008-US 012M17 Page 2 of 2