WS-18-3008Miami Shores Village
Building Department
10050 NE 2 Ave
Miami Shores FL 33138
Permit NO. WS-10-18-3008
Type: Windows/Shutters
Workclass: Window/Door Replacement
Permit Status: Approved
Issue Date: 10/16/2018 Expires: 04/01/2019
INSPECTION REQUESTS: (305)762-4949 or log on at https://bldg.msvfl.gov energov_prod/selfservice
Requests must be received by 3:30pm
WORK IS ALLOWED: MONDAYTHROUGH FRIDAY, 8:OOAM - 7:OOPM
SATURDAY 8:OOAM - 6:00PM.
NO WORK IS ALLOWED ON SUNDAY OR HOLIDAYS
BUILDING AND ROOFING INSPECTIONS ARE DONE MONDAYTHROUGH FRIDAY .
NO INSPECTION WILL BE MADE UNLESS THE PERMIT CARD IS DISPLAYED AND HAS BEEN APPROVED . PLANS ARE
READILY AVAILABLE . IT IS THE PERMIT APPLICANT'S RESPONSIBILITY TO ENSURE THAT WORK IS ACCESSIBLE AND
EXPOSED FOR INSPECTION PURPOSES. NEITHER THE BUILDING OFFICIAL NOR THE CITY SHALL BE LIABLE FOR
EXPENSE ENTAILED IN THE REMOVAL OR REPLACEMENT OF ANY MATERIAL REQUIRED TO ALLOW INSPECTION .
POST ON SITE
1122320280490
Owner's Name: PETER KONEN
Job Address: 10674 NE 11TH CT
Miami Shores, FL 3313
Owner's Phone:
Total Square Feet: 0
Total Job Valuation: $ 2,707.83
Contractor(s) Phone
SOUTH FLORIDA RESTORATION INC (305)651-9660
Address
675 NW 116 ST, MIAMI, FL 33158
Description: IMPACT WINDOW INSTALLATION
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS
TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED
AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF
COMMENCEMENT.
Page 1 of 1
INSPECTION RECORD
STRUCTURAL
INSPECTION DATE
INSP
Foundation
Stemwall
Slab
Columns (1st Lift)
Columns (2nd Lift)
Tie Beam
Truss/Rafters
Roof Sheathing
Bucks
Interior Framing
Insulation
Ceiling Grid
Drywall
Firewall
Wire Lath
Pool Steel
Pool Deck
Final Pool
Final Fence
Screen Enclosure
Driveway
Driveway Base
Tin Cap
Roof in Progress
Mop in Progress
Final Roof
Shutters Attachment
Final Shutters
Rails and Guardrails
ADA compliance
DOCUMENTS
Soil Bearing Cert
Soil Treatment Cert
Floor Elevation Survey
Reinf unit ivias Cert
Insulation Certificate
Spot Survey
Final Survey
Truss Certification
STRUCTURAL COMMENTS
-WINDOWS & DOORS
INSPECTION DATE
INSP
Attachment I
FINAL
/l
PUBLIC WORKS
INSPECTION DATE
INSP
Excavation
FINAL
ELECTRICAL
INSPECTION
DATE
INSP
Temporary Pole
30 Day Temporary
Pool Bonding
Pool Deck Bonding
Pool Wet Niche
Underground
Footer Ground
Slab
Wall Rough
Ceiling Rough
Rough
Telephone Rough
Telephone Final
TV Rough
TV Final
Cable Rough
Cable Final
Intercom Rough
Intercom Final
Alarm Rough
Alarm Final
Fire Alarm Rough
Fire Alarm Final
Service Work With
FINAL
ELECTRICAL
COMMENTS
INSPECTION
FIRE
DATE
INSP
Final Sprinkler
Final Alarm
FINAL
Rough
Water Service
2nd Rough
Top Out
Fire Sprinklers
Septic Tank
Sewer Hook-up
Roof Drains
Gas
LP Tank
Weil
Lawn Sprinklers
Main Drain
Pool Piping
Backflow Preventor
Interceptor
Catch Basins
Condensate Drains
HRS Final
Oraimmou
PLUMBING COMMENTS
INSPECTION DATE INSP
Underground Pipe
Rough
Ventilation Rough
Hood Rough
Pressure Test
Final Hood
Final Ventilation
Final Pool Heater
Final Vacuum
FINAL
MECHANICAL COMMENTS
BUILDING
PERMIT APPLICATION
ElBUILDING D ELECTRIC
❑PLUMBING ❑ MECHANICAL
JOB ADDRESS: 10674 NE 11 CT
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
❑ ROOFING
El PUBLIC WORKS
Master Permit No.
Sub Permit No.
❑ REVISION ❑ EXTENSION ❑RENEWAL
RECEIVED
OCT 02 2018
FBC 201.4
WS -2c08
❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
City: • Miami Shores
Folio/Parcel#:11-2232-028-0490
County:
Occupancy Type:
Miami Dade Zip:
Is the Building Historically Designated: Yes' NO
Load:.. Construction Type: Flood Zone: BFE: FFE
OWNER: Name (Fee Simple Titleholder): PETER L KONEN
Address:10674.NE 11 CT
Phone#: (305) 505-1208
city:-MIAMI SHORES
State: FL Zip,' 33138
Tenant/Lessee Name:
Email: konenp@bellsouth.net
Phone#:
CONTRACTOR: Company Name: South Florida Restoration, Inc.
Address: 675 NW 116th Street
Phone#: 305-651-9660
City: Miami State: FL
Qualifier Name: David lannacone
State Certification or Registration #: CGC052795
DESIGNER: Architect/Engineer: Chris Casariego
Phone#:
Zip: 33168
954-253-6783
Certificate of Competency #:
954-275-0826
Phone#:
Address:4530 N. Hiatus RD Suite 101 City: Miami state: FL zip: 33168
Value of Work for this Permit: $ 2,707.83
Type of Work: ❑ Addition ❑ Alteration
Description of Work: Impact Window Installation
Square/Linear Footage of Work:
❑ New 0 Repair/Replace
7 Wlnle,w5
❑ Demolition
Specify color•ofcolor thrutile:
Submittal Fee $ Permit Fee $
Scanning Fee $
Radon Fee $
Technology Fee $
Structural Reviews $
CCF $ , . CO/CC.$.,
DBPR $'> . ' Notary $
Training/Education Fee $ Double Fee $
Bond $
TOTAL FEE NOW DUE $ 13
(Revised02/24/2014)
Bonding Company's Name (if applicable)
Bonding Company's Address E ¢ t r
City State
Mortgage Lender's Nettie -Of applicable) '
a +p '• f
Mortgage Lender's Address
City ' r, ., State' R. F,,E Zip
( �t
Zip
• "¢" '' . ' v: ''�d 4 _ 'I
t r1' 1 ,1 . p 1% , .' . Lr w1 1 . ,
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance. of„a.per`mit and that all work will be performed to meet the standards of, all laws • regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS,; TANKS, AIR CONDITIONERS, ETC.....;- - -
f�. 6. i • 1 . - $ , -, 1 I r , ill 1_ :L1., { { `+J I.
A* %' . 1 1 tt.t Ls". - t. z`- • 1
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.•
"WARNING TO OWNER: -YOUR FAILURE' TO RECORD -A:NOTICE ,OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE- FOR`IMPROVEMENTS-TO-YOUR.PROPERTY. IF -YOU INTEND
TO OBTAIN FINANCING;,CONSULT WITH YOUR.LENDER OR AN ATTORNEY -BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
-
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500; the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be -delivered to the person
•
whose property is subject to attachment -Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged. , (-1 ,
Signature _.
Signature
`OWNER orAGENT - - -" CONTRACTOR �A -'
The foregoing'instiument was acknowledged.befo-i--e'rne this ... -The foregoing instrument was acknowledged before me this
y of � daCy 20 (� _ _.-_by _ gtp day of _- C.) k_l' _._..' ,.' ;20'11 ,i by .. .
?tap:. � / j, who is personally known to . �-f'�Q
1V1(1 `Lrj(ir,CDr►�J who is ersonally know to
me or who has produced as ` me or who his -prod LI-c--e-d
identification and who did take In -Oath. -
NOTARY PUBLIC:
Sign:
Print: --•
Seal:
SHELLIE L FULFORD
1 , : Notary Public - State of Florida `
��{cf My Comm. Expires Feb 28, 2021- -
APPROVED BY
identification and who did take an oath.
f Y 1 ,9.
NOTARY PUBLIC: •
•
r
Sign:
- - Print:
Seal:
1 ,1. ..
Plans Examiner
401, J ,.
ILDA LOPEZ
c MY COMMISSION # GG056663
EXPIRES December 20,'2020-
J
• r�
as
Zoning
(Revised02/24/2014)
fi .
W
- :'
Structural Review y Clerk
• Miami Shores Viiiage
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Inspection requirements for:
Windows, Doors, Skylights or Fixed Glass (cladding) Permits
Upon issuance of permits for the scope of work involving the removal, changing and/or
replacement of any type of windows, doors, sidelites, skylights or fixed glass (cladding)
the permit holder or qualifier bearing his signature on the permit application shall abide
by the requirements of this department and comply with the following statement:
Upon obtaining window and/or door permits for the installation of same, it is the
responsibility of the permit holder to request window/door framing in -progress
inspection, prior to concealment of any horizontal or vertical clip mullion, bucks, shims,
etc. Inspector will also verify anchor type, edge distance, embedment and spacing. The
purpose for this inspection, is for the verification of conformance with Product
Approval (NOA).
Acknowledgement:
Qualif4Owner Signature Date Print Name
6e—+
1 '4 _Thv‘ d -4-an n.along2--
10/2/2018 Property Search Application - Miami -Dade County
Summary Report
Property Information
Folio:
11-2232-028-0490
Property Address:
10674 NE 11 CT
Miami Shores, FL 33138-2123
Owner
PETER L KONEN
MARISOL SARDINA
Mailing Address
10674 NE 11 CT
MIAMI SHORES, FL 33138 USA
PA Primary Zone
0800 SGL FAMILY - 1701-1900 SQ
Primary Land Use
0101 RESIDENTIAL - SINGLE
FAMILY : 1 UNIT
Beds / Baths / Half
3/2/0
Floors
1
Living Units
1
Actual Area
1,905 Sq.Ft
Living Area
1,472 Sq.Ft
Adjusted Area
1,683 Sq.Ft
Lot Size
9,750 Sq.Ft
Year Built
1952
Assessment Information
Year
2018
2017`
2016
Land Value
$239,085
$239,085
$177,606
Building Value
$98,960
$98,960
$98,960
XF Value
$0
$0
$0
Market Value
$338,045
$338,045
$276,566
Assessed Value
$183,456
$179,683
$175,988
Benefits Information
Benefit
Type
2018
2017
2016
Save Our Homes
Cap
Assessment
Reduction
$154,589
$158,362
$100,578
Homestead
Exemption
$25,000
$25,000
$25,000
Second Homestead
Exemption
$25,000
$25,000
$25,000
Note: Not all benefits are applicable to all Taxable Values (..e. County, School
Board, City, Regional).
Short Legal Description
MIAMI SHORES ESTATES PB 47-58
LOT 21 BLK 3
LOT SIZE 75.000 X 130
OR 19408-0757 12 2000 1
Generated On : 10/2/2018
Taxable Value Information
2018
i
20171 2016
County
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$133,456
$129,683
$125,988
School Board
Exemption Value
$25,000
$25,000
$25,000
Taxable Value
$158,456
$154,683
$150,988
City
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$133,456
$129,683
$125,988
Regional
Exemption Value
$50,000 $50,000
$50,000
$125988
Taxable Value
i $133,456 $129,683
Sales Information
Previous
price OR Book -
Qualification Description
Sale
e
Page
08/11/2014
$101,315 29276-1429
Corrective, tax or QCD; min
consideration
12/01/2000
$158,000 19408-0757
Sales which are qualified
07/01/1998
$112,800 18191-4239
Sales which are qualified
05/01/1992
$85,000 15529-4127
Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property
Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
Version:
T
MIAMI-DADE COUNTY
DUCT CONTROL SECTION
11805 SW 26 Street, Room 208
786) 315-2590 F (786) 315-2599
www.miamidade.aov/economy
•
reserves the right to revoke this acceptance, if it is determined by Miami -Dade, caunty PrQdunt Contras' • •
Section that this product or material fails to meet the requirements of the applicabre.bxilding coffin..'
This product is approved as described herein, and has been designed to comply with; he Ftarida puildin ' • • •
Code, including the High Velocity Hurricane Zone. • • • • • • •
DESCRIPTION:"Series "Eco-Guard,200" AIuminum Horiib al Rolling Window ; L.M,I.— •
APPROVAL DOCUMENT: Drawing No. W09-12, titled "Eco-Guard Series-20P Nev. Hotiz. Rolling •
Wdw. (L_M.I.)" sheets 1 through 7 of 7, dated 02/24/09, with revision F dated 10/19717, prepared b'.A1- •
Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Vroduct
Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade
County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 15-0728.05 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as
well as approval document mentioned above.
The submitted documentation was reviewed by Sifang Zhao, P.E.
4,2.
DEPARTMENT OF REGULATORY AND ECONOMIC R
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Eco Window Systems, LLC
8502 NW 80 Street
Medley, FL 33166
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) rq •eino-the right
to have this product or material tested for quality assurance purposes. If this itodj.ttt or n?aterial fails•tt? • •
perform in the accepted manner, the manufacturer will incur the expense of such'testing and WAHJ ma
immediately revoke, modify, or suspend the use of such product or material witl}ip• ,ir jurisdi ;tion. R• • •
(NOA No. 17-1102.23 —
ppiration Date:_ May 27, 2019
Approval Date: January 11, 2018
Page 1
•
Eco Window Systems, LLC.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Manufacturer's die drawings and sections.
(Submitted under NOA#09-0312.08)
2. Drawing No W09-12, titled "Eco-Guard Series-200 Alum. Horiz. Rolling Wdw.
(L.M.I.)", sheets 1 through 7 of 7, dated 02/24/09, with revision F dated 10/19/17,
prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E.
B. TESTS
1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94 • •
3) Cyclic Wind Pressure Loading per FBC, TT6.2Q3-94•
4) Forced Entry Test, per FBC 2411.3.2.1, and'tAS 202+9 : • • •
along with marked -up drawings and installation diagram of at; aluminum horizontal. •
sliding window, prepared by Fenestration Testing Laboratory, ine ;Test gvpurt No. • •
FTL-7635, dated 12/09/14, signed and sealed by Marlin D. BritigOn, P.E. • • • •
(Submitted under..:?J1#14. f 3.17?01)
2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 •'
2) Uniform Static Air Pressure Test, Loading per FtiC T 2-94 •
3) Water Resistance Test, per FBC, TAS 202:94 • • • •
•
4) Forced Entry Test, per FBC 2411 3.2.1, TA •202-94 • .. • . • •
along with marked -up drawings and installation diagram of a XOX aluminum
horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test
Report No. HETI-08-2226A, dated 01/15/09, signed and sealed by Candido F. Font,
P.E. (Submitted under NOA#09-0312.08)
3. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a XOX aluminum
horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test
Report No. HETI-08-2226B, dated 01/15/09, signed and sealed by Candido F. Font,
P.E. (Submitted under NOA#09-0312.08)
4. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
along with marked -up drawings and installation diagram of a XOX aluminum
horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test
Report No. HETI-08-2227, dated 01/15/09, signed and sealed by Candido F. Font,
P.E. (Submitted under NOA#09-0312.08)
VanZAaro
Sifang Zhao, P.E.
Product Control Examiner
NOA No. 17-1102.23
Expiration Date: May 27, 2019
Approval Date: January 11, 2018
E-1
Eco Window Systems, LLC.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS (CONTINUED)
5. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94
along with marked -up drawings and installation diagram of a XOX aluminum
horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test
Report No. HETI-08-2228A, dated 01/15/09, signed and sealed by Candido F. Font,
P.E. (Submitted under NOA#09-0312.08)
6. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94
2) Cyclic Wind Pressure Loading per FBC, Tg1.S,2Q3-94•
along with marked -up drawings and installation diagram of a XbX'alumirium • ' •
horizontal sliding window, prepared by Hurricane EngineeringAt Zesting, lac., Test.
Report No. HETI-08-2228B, dated 01/15/09, signed and seale d•loy Cand;ele•F.Font;
P.E. (Submitted undeeN9A#09-O512.08) . •
7. Test reports on: 1) Large Missile Impact Test per FBC, TAS 1Q;;34 •
2) Cyclic Wind Pressure Loading per FBC, TAS.203-94 ••
along with marked -up drawings and installation diagram of a kO)C:alumtippg. •
horizontal sliding window, prepared by Hurricane Engineerink &Testing, Inc., Test'
Report No HETI-08-2229, dated 01/15/09, signed and sealed Ty C•andidq'•ont, •
P.E. (Submitted under NOA#09-0312.08)
8. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a XOX aluminum
horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test
Report No. HETI-08-2230A, dated 01/15/09, signed and sealed by Candido F. Font,
P.E. (Submitted under NOA#09-0312.08)
9. Test reports on: 1) Large Missile Impact Test per FBC, TAS 201-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a XOX aluminum
horizontal sliding window, prepared by Hurricane Engineering & Testing, Inc., Test
Report No. HETI-08-2230B, dated 01/15/09, signed and sealed by Candido F. Font,
P.E. (Submitted under NOA#09-0312.08)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 5th
Edition (2014), dated 07/08/15, complying with FBC 6« Edition (2017), dated
10/12/17 prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E.
2. Glazing complies with ASTM E1300-09
Sifang Zhao, P.E.
Product Control Examiner
NOA No. 17-1102.23
Expiration Date: May 27, 2019
Approval Date: January 11, 2018
E-2
•
Eco Window Systems, LLC.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their
"Trosifol® Ultraclear, Clear and Color PVB Interlayers" dated 01/19/17, expiring
on 07/08/19.
2. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their
"SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on
07/04/18.
•
F. STATEMENTS
••
• • •
•
•••• •
• e •
1. Statement letter of conformance, complying with FBC 5th Editiea:E2014), with FBC
Edition (2017), and of no financial interest, dat d October 11'201.7, prOdfed by
Farooq Corporation, signed and sealed by Javad • • ad, P.E. "• • • • `•
• • • • •
••• •• ••
A`'•
.•. •
•
G. OTHER
1. Notice of Acceptance No. 15-0728.05, issued to Eco Window'Systthns, ILtufnr their
Series "Eco-Guard 200" Aluminum Horizontal Rolling Windom4M.I.4,ppproveci
on 09/03/15 and expiring on 05/27/19. ' '•
E-3
•'•
•
54 j M4'
Sifang Zhao, P.E.
Product Control Examiner
NOA No. 17-1102.23
Expiration Date: May 27, 2019
Approval Date: January 11, 2018
•
3 1/2" MAX.
HEAD/SILL
CORNERS
a_
O
0
FALSE MUNTINS
(SURFACE APPLIED)
MAY BE USED
I I
31 1/4"
72"
I I
I I
32 3/4"
D.L. OPG.
35 3/8"
VENT WIDTH
D.L. OPG.
3 1/2" MAX.
HEAD/SILL
CORNERS
111"
WINDOW WIDTH
10 5/8" MAX.
HEAD/SILL
CORNERS
/ 1 I I \
i
/1
•
•
•
WINDOW HEIGHT
58 3/4"
VENT HEIGHT
55 7/8"
'i
__
_4_
11
'I
_
i'
--/ _
-Z.-
/ '
o
O
_
=-err-1-�'-Im-=
i �1J.
1
_
1
_
=-�r----r
i/li
1
_
1
'%
C�m
V ,
-
3
•
1 ,1
It l `. I 1 el
I I \. 1
J
FALSE MUNTINS
(SURFACE APPLIED)
MAY BE USED
TYPICAL ELEVATIONS
0RESE-WINDOWS ,.ARE:RATED_FOR-LARGE.& =SMALL MISSILE -IMPACT:
:SHUTTERS:ARE_NOT REQUIRED-
1/8" HEAT STREN'D. GLASS
.090" Interlayer
Trosifol PVB
By 'Kuraray America, Inc.'
1/8" HEAT STREN'D. GLASS
SIUCONE
DOW CORNING 899 a
GE SCS 2000
z
AT 1/4 POINTS ON LITES
WIDER THAN 36" ONLY
GLASS TYPE 'A'
1/8" HEAT STREN'D. GLASS
.090" Interlayer
SentryGlas
By 'Kuraray America, Inc.'
1/8" HEAT STREN'D. GLASS
SILICONE
DOW CORNING 899
GE SCS 2000
AT 1/4 POINTS ON LEES
WIDER THAN 36" ONLY
GLASS TYPE 'B'
GLAZING OPTIONS
6" MIN. TYP.
cs
I \I
32 3/4"
D.L. OPG.
36 7/8"
VENT WIDTH
32 3/4"
j
1
D.L. OPG.
TO QUAUFY FOR SMALL MISSILE IMPACT RATING
EXTERIOR PLY OF GLASS TYPE 'C' MUST BE TEMPERED.
1/8" HEAT STREN'D. GLASS
5/16" AIR SPACE
1/8" HEAT STREN'D. GLASS
.090" Interlayer
Trosifol PVB
By 'Kuraray America, Inc.'
1/8" HEAT SIRE-N.D. GLASS
CARDINAL XL
EDGE SPACER
ST. STEEL
SIUCONE
DOW 899
AT /4 POINTS
ALL SIZES
GLASS TYPE 'C'
ECO— GUARD
(2)ANCHORS AT MTG. STILE ENDS TYP.
(4ANCHORS REQD. FOR SIZES AND LOADS
MARKED WITH '•' ON SHEET 2 ONLY
SERI
ALUMINUM HORIZ
0;
DESIGN LOAD RATINGS FOR
CHARTS SHOWN ON SHEETS
TAB
0
0
c
as
v
U
CO
CL
APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE
COMBINATIONS OF H.R./H.R. OR HORIZONTAL ROLUNG WITH OTHER___
WINDOW TYPES IN MODULES OF TWO -OR MORE WINDOWS USING
MIAMI-DADE COUNT`( ,APPROVED MULUONS IN BETWEEN.
LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL •.. •
WILL APPLY TO ENTIRE SYSTEM.
THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITHLTHE,
fREQUIREMENTS-OF - THE --2014-(5TH-EDITION)%2017}(6TH EDEION) .FLORIDA ."'•
BUILDING -CODE -INCLUDING -HIGH -VELOCITY HURRICANE ZONE (HVHZ). • • • •
1BY OR 28Y WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE
DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPUED PRODUCT LOAM • •
TO THE BUILDING STRUCTURE.
•
ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS •
AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE • •
MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. • •
A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY.
ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON -COMPRESSIBLE.
MATERIALS INCLUDING BUT NOT UMITED TO STEEL/METAL SCREWS, THAT
COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE
REQUIREMENTS OF THE 2014/2017 FLORIDA BLDG. CODE & ADOPTED STANDARDS.
THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION
FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY
OF STRUCTURE RECEIVING THIS PRODUCT AND SEAUNG AROUND OPENING FOR
WATER INFILTRATION RESISTANCE ETC.
CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY,
AND TO BE REVIEWED BY BUILDING OFFICIAL.
SETTING BLOCKS AT
LAM. GLASS AND INSUL LAM. GLASS
NOTCH GLAZING BEAD LEG TO CLEAR BLOCKS
PRODUCT
Ds comply ez2i ,vi , iate F :cr:do
Building Code
N011-1v F11-_z3
Expiration Date -Q&bi 1 Zo tR
By Zhao
14iami Dade Prxh.:.ct t'.en/roi
olo
60.
``J lllllt/��y'
70592
••
•
8
N
J
-J
Vi
v,
w
(/) V) co
T 0)
C3 OM
2 o3•. utj
FAX (305) 885-5902
••. •
in
0
in
.5
••
•
•
0
0.
.c
0
co
o
R.
•
4
0
g.
.0
0)
0
0
0
r
di
c,
0
c
0
O
W
L.
aV
N
0
v
0
N,
c
Q
EE
drawing no.
W09-12
(sheet 1 of 7
•
•
DESIGN LOAD CAPACITY - PSF (X0, OX OR XX SIZES)
WINDOW DIMS.
A
W/0 REINF.
WITH REINF.
GLASS TYPE
'A'
GLASS TYPE
'B'
GLASS TYPE
'C'
WIDTH
HEIGHT
EXT.(+)
INT.(-)
EXT.(+)
INT.(-)
EXT.(+)
INT.(-)
26-1/2"
37"
53-1/8"
74"
26"
(3)
4
70.0
80.0
80.0
90.0
70.0
80.0
4
70.0
80.0
80.0
90.0
70.0
80.0
6
70.0
80.0
80.0
90.0
70.0
80.0
8
70.0
80.0
80.0
90.0
70.0
80.0
26-1 /2"
37"
53-1/8"
74"
18-3/8"
4)
4
70.0
80.0
80.0
90.0
70.0
80.0
4
70.0
80.0
80.0
90.0
70.0
80.0
6
70.0
80.0
80.0
90.0
70.0
80.0
8
70.0
80.0
80.0
90.0
70.0
80.0
26-1/2"
37"
53-1/8"
74"
50-5/8"
(5)
4
70.0
80.0
80.0
90.0
70.0
80.0
4
70.0
80.0
80.0
90.0
70.0
80.0
6
70.0
80.0
80.0
90.0
70.0
80.0
8
70.0
80.0
80.0
90.0
70.0
80.0
26-1/2"
37"
53-1/8"
74"
63"
(6)
4
70.0
80.0
80.0
90.0
70.0
80.0
4
68.9
77.5
80.0
90.0
70.0
80.0
6
70.0
70.0
80.0
90.0
70.0
80.0
8
70.0
70.0
80.0
80.4 *
70.0
80.0
24"
36"
48"
60"
72"
�3)
4
70.0
80.0
80.0
90.0
70.0
80.0
4
70.0
80.0
80.0
90.0
70.0
80.0
6
70.0
80.0
80.0
90.0
70.0
80.0
6
70.0
80.0
80.0
90.0
70.0
80.0
8
70.0
80.0
80.0
90.0
70.0
80.0
24"
36"
48"
60"
72"
�4)
4
70.0
80.0
80.0
90.0
70.0
80.0
4
70.0
80.0
80.0
90.0
70.0
80.0
6
70.0
80.0
80.0
90.0
70.0
80.0
6
70.0
80.0
80.0
90.0
70.0
80.0
8
70.0
80.0
80.0
90.0
70.0
80.0
24"
36"
48"
60"
72"
48.
(5)
4
70.0
80.0
80.0
90.0
70.0
80.0
4
70.0
80.0
80.0
90.0
70.0
80.0
6
70.0
80.0
80.0
90.0
70.0
80.0
6
70.0
80.0
80.0
90.0
70.0
80.0
8
70.0
80.0
80.0
90.0
70.0
80.0
24"
36"
48"
60"
72"
(6)
4
70.0
80.0
80.0
90.0
70.0
80.0
4
70.0
80.0
80.0
90.0
70.0
80.0
6
70.0
70.0
80.0
90.0
70.0
80.0
6
70.0
70.0
80.0
90.0
70.0
80.0
8
70.0
70.0
80.0
87.6 *
70.0
80.0
A = NO.
( ) = NO.
OF ANCHORS
OF ANCHORS
* MAX.
WITH
PER HEAD & SILL
PER JAMB
LOAD FOR THESE SIZES IS -90.0 PSF
(4) ANCHORS AT MTG. STILE ENDS
4
LEFT AND RIGHT VENTS TO BE OF EQUAL GLASS DLO WIDTHS
'X0 OR OX'
DESIGN LOAD CAPACITY - PSF (XOX SIZES)
WINDOW DIMS.
A
W/O REINF.
WITH REINF.
GLASS TYPE
'A'
GLASS TYPE
'B'
GLASS TYPE
'C'
WIDTH
HEIGHT
EXT.(+)
INT.(-)
EXT.(+)
INT.(-)
EXT.(+)
INT.(-)
74"
106-1/4"
111"
26"
(3)
9
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
74"
106-1/4"
111"
38-3/8"
(4)
9
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
74"
106-1/4"
111"
50-5/8"
(5)
9
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
74"
106-1/4"
111"
"
(6)
9
70.0
70.0
80.0
90.0
70.0
80.0
12
70.0
70.0
80.0
82.6 *
70.0
80.0
12
70.0
70.0
80.0
80.4 *
70.0
80.0
72"
84"
96"
108"
24"
(3)
9
70.0
80.0
80.0
90.0
70.0
80.0
9
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
72"
84"
96"
108"
36"
(4)
9
70.0
80.0
80.0
90.0
70.0
80.0
9
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
72"
84"
96"
108"
48"
(5)
9
70.0
80.0
80.0
90.0
70.0
80.0
9
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
72"
84"
96"
108"
60"
(6)
9
70.0
70.0
80.0
90.0
70.0
80.0
9
70.0
70.0
80.0
90.0
70.0
80.0
12
70.0
70.0
80.0
90.0 *
70.0
80.0
12
70.0
70.0
80.0
87.6 *
70.0
80.0
A = NO. OF ANCHORS PER HEAD & SILL
( ) = NO. OF ANCHORS PER JAMB
* MAX. LOAD FOR THESE SIZES IS -90.0 PSF
WITH (4) ANCHORS AT MTG. STILE ENDS
(1/3W)
(1/3W).
(1/3w)
4
OPERATING VENTS TO BE 1/3 OF THE WINDOW WIDTH
'XOX'
DESIGN LOAD CAPACITY - PSF (XOX SIZES)
WINDOW DIMS.
A
W/0 REINF.
WITH REINF.
GLASS TYPE
'A'
GLASS TYPE
'B'
GLASS TYPE
'C'
WIDTH
HEIGHT
EXT.(+)
INT.(-)
EXT.(+)
INT.(-)
EXT.(+)
INT.(-)
74"
106-1/4"
111"
(3)
9
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
74"
106-1/4"
111"
38-3/8"
(4)
9
70.0
80.0
80.0
90.0
70.0
80.0
12
-
-
80.0
90.0
70.0
80.0
12
-
-
80.0
90.0
.70.0
80.0
74"
50-5/8"
(5)
9
70.0
80.0
80.0
90.0
70.0
80.0
74"
63"
(6)
9
70.0
70.0
80.0
90.0
70.0
80.0
72"
84"
96"
108"
24"
(3)
9
70.0
80.0
80.0
90.0
70.0
80.0
9
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
72"
84"
96"
108"
36"
(4)
9
70.0
80.0
80.0
90.0
70.0
80.0
9
70.0
80.0
80.0
90.0
70.0
80.0
12
70.0
80.0
80.0
90.0
70.0
80.0
-
-
80.0
90.0
70.0
80.0
72"
84")
96"
4-8"
9
70.0
80.0
80.0
90.0
70.0
80.0
9
70.0
70.0
80.0
90.0
70.0
80.0
12
70.0
70.0
80.0
90.0
70.0
80.0
72"
60'
(6)
9
70.0
70.0
80.0
90.0
70.0
80.0
ALL EXTERIOR(+) LOADS SHOWN ON THIS SHEET ARE
FOR WINDOWS WITH ADD -ON RISER AT FRAME SILL
FOR STD. SILL (NO RISER) LIMIT EXT.(+) LOADS TO 67.0 PSF
SEE SHEET 3 FOR DETAIL.
A = NO. OF ANCHORS PER HEAD & SILL
( ) = NO. OF ANCHORS PER JAMB
(1/4W)
4
OPERATING VENTS TO BE 1/4 OF THE WINDOW WIDTH
'XOX'
••
• •
••
•
•
• • • •
• • •
•
•• .•
• • •
• •
• •
• • •
.• •
NOTE:
GLASS CAPACITIES ON THIS SHEET ARE
BASED ON ASTM E1300-09 (3 SEC. GUSTS)
AND FLORIDA BUILDING COMMISSION
DECLARATORY STATEMENT DCAO5-DEC-219
fie c_:r,splrill_; ::'!'r=: c:::: Fif::1..4L;41
cs:lrsE i� `�:liyC
Ac aT;. icc 1-f}o2 5
Expirations Date __ 7t
BY S' ?1,1447
IVEiani Dscle 1'r net Contrc4P
,111111111//��'
EhNi40
ATE OF
OR10P. •
�NAttie`�
i`
z
• n.
Oego
4 11 ..
mot I.
Rr"
Clarct
O n. a
O 4 b Ei
rglqui
ZN-
QWC12
C
0
w
N
Q.
0
FAX (305) 885-5902
)
in
0
in
••
•
•
0.
0
co
to
0
•
.�
m0
N
n_
0
0
g
8
0
0
'0
0
0
0
C
0
0.
Ial
1
0
0
N
O
1
8
0
c
drawing no.
W09-12
(sheet 2 of 7
0
1BY
WOOD BUCK
• o
4 4 a'
a
4
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
EDGE. DIST: •
a
•
z
0
:I
II
it
EDGE DIST.
a
q
a. •
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
-J
U)
co
N
EDGE DIST.
METAL.
STRUCTURE
N
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
v. 1BY
WOOD BUCK
EDGE DIST.
MIAMI—DADE COUNTY APPROVED
MUWON do MUWON ANCHORS
SEE SEPARATE NOA
EDGE DIST.*
TYP CAL ANCHORS
SEE ELEV.
FOR SPACING
WEEPHOLES:
W1 = 3/8" X 2-1/4" WEEPHOLES AT EACH END
AND 37" O.C. MAX.
SEALANT:
ALL JOINTS AND FRAME CONNECTIONS SEALED WITH
JOINT SEALER.
v. ' >.
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
DIST
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
WOOD BUCKS AND METAL STRUCTURE NOT BY ECO WDW.
MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM
AND TRANSFER THEM TO THE BUILDING STRUCTURE.
TYPICAL ANCHORS: SEE ELEV. FOR SPACING
1/4" DIA. ULTRACON BY tELCO' (Fu-177 KSI, Fy-155 KSI)
INTO 2BY WOOD BUCKS OR WOOD STRUCTURES
1-1/2" MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS)
THRU 18Y BUCKS INTO CONC. OR BLOCKS
1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS)
1-1/4" MIN. EMBED INTO BLOCKS (JAMBS)
DIRECTLY INTO CONCRETE OR BLOCKS • •
1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS•••
1-1 /4" MIN. EMBED INTO BLOCKS (JAMBS)
#14 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS)
INTO MIAMI—DADE COUNTY APPROVED MUWONS
OR
INTO METAL STRUCTURES (HEAD/SILL/JAMBS)
(3) THREADS MIN. PENETRATION BEYOND SUBSTRATE
ALUMINUM: 1/8" THK. MIN. (6063—T5 MIN.)
STEEL: 1/8" THK. MIN. (Fy = 36 KSI MIN.)
(STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED)
TYPICAL EDGE DISTANCE
INTO CONCRETE AND MASONRY = 2-1/2" MIN.
INTO WOOD STRUCTURE = 1" MIN.
INTO METAL STRUCTURE = 3/4" MIN.
WOOD AT HEAD, SILL OR JAMBS SG = 0.55 MIN.
CONCRETE AT HEAD, SILL OR JAMBS f'c = 3000 PSI MIN.
C-90 HOLLOW/FILLED -BLOCK AT JAMBS fm = 2000 PSI MIN.
•
• • • •
• • • •
•
•• ••
PRODUCT REVISED
as con plying with the Florida
Building Code
Acceptance No
Expiration Date
Miami a ciProduct Control
1102.13
o111I111
. 70592
• • ,
•
• •
• •• .
•• 4
re"
V
COMP-ANL\W09-
c
FAX (305) 885-5902
m
u7
co
c
O
r
0
y
c
0
a
0
d
0
••
•
•
z
i
•
•
•
El
N
N
0
L
0
0
O
O
tri
O
0)
G
0
c
0
O
W
N
0
q
§a
0
u
drawing no.
W09-12
sheet 3 of 7
1/4" MAX.
HIMS
S
1
1
ft.
STEEL REINFORCING
AS REQD.
SEE SHEET 2 FOR CAPACITY
WINDOW WIDTH
1 /4" MAX.
SHIM
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
w
0
w
METAL
STRUCTURE
1/4" MAX.
SHIM
'TYPICAL ANCHORS
—SEE ELEV.
FOR SPACING
VENT WIDTH
D.L. OPG.
--SCREEN OPT
XO LAYOUT
EXTERIOR
MIAMI—DADE COUNTY
APPROVED MULLION
SEE SEPARATE NOA
D.L OPG.
WINDOW WIDTH
XOX LAYOUT
TYPICAL ANCHORS
SEE ELEV. FOR SPACING
• v
1BY
WOOD BUCKS
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
0
w
VENT WIDTH
SCREEN 0
STEEL REINFORCING
AS REQD.
SEE SHEET 2 FOR CAPACITY
e^J
SCREEN OPT.
WINDOW WIDTH
WINDOW WIDTH
1 /4" MAX.
SHIMS
1BY
WOOD BUCKS
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
PRODUCT J:F_VWSE:b
as complying with the Florida
Building Code
Acceptance No 1 /-1101. 2%3
Expiration Date iainizolq
By fta.+�
Miami Dade Jaic .r :l
• •
• • •
•• t
•...
•
••••
1
• 4
•• ••
• • •
•
• •
• • •
•• •
`��1llllllf�Qe
v.;•• VGEN •-••.
•
; No 70592 •
i =
0
U
FAX (305) 885-5902
885-5299
0
c
0
a
.`
0
to
N
311•
•
•
•
L
•
•
fl
2
0
•
a
•
N
0
c
j
f/)
0
d
t./
Q)
0
M
O
0
n
0i
0
0
C
0
0
L.
0,
0
0
ep
0
1
0
ATE OF : 41,/,::::
ORIDP .•t%�®`��
®NAL \‘`'
drawing no.
wog-12
(sheet 4 of 7
•
•
•
ALT.
• • \
EDGE DIST.
v•
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
TYPICAL. ANCHORS
SEE ELEV. FOR SPACING
x
to
METAL
STRUCTURE
EDGE
DIST.
78.1.1
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
MIAMI—DADE COUNTY APPROVED
MUWON & MULLION ANCHORS
SEE SEPARATE NOA
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
INSTALLATION DETAILS WITH FLUSH FRAME ADAPTER
PRODUCT REVISED
as complying with the Florida
Building Code
Acceptance Ak> '1- !OZ. . 3
Expiration Date R
By S% f4/15 2h4,0
Miami Dade Prot t Control
• •
• •
.. 4
.
• • • •
. •
• • • •
.
•.••
• • •
• •
• •
• • •
•• •
0
a
J I
J
o
0
W
w
v)m
Qrn
E L
o�o
••• 0
�
•
•.
in
C
•
•
C
O
o
a)
.0
•
N•
fl
a
0
0
0
4.
0
N_
a
N
c
O
0 •
1
N
U
G
•
N
0
W
drawing no.
W09-12
sheet 5 of 7
2.750
3.249
.813
.062
1.140 1.610 --a
01 FRAME HEAD
.500
1.718
3/16"
r-
tctl \.
12
O VENT TOP/BOTTOM RAIL
ri
STEEL REINFORCING
--1.140�1.610�
.813
3.876
-•-.078
1.058
2.501
.500
0
2.750
FRAME SILL
.045
GLAZING BEADS
0 JAMB STILE
0 MEETING RAIL
0
SILL TRACK
0
.1871
.062
2.812
.874 I..-
MOV. FRAME JAMB
Og FIXED MTG. RAIL
0 FIXED FRAME JAMB
2.688
28 FLUSH FRAME ADAPTER
ITEM
PART #
QUANTITY
DESCRIPTION
MATERIAL
MANP./SUPPLIER/REMARKS
1
FY201
1
FRAME HEAD
6063-T6
-
2
FY202
1
FRAME SILL
6083-T6
-
3
FY203
1
SILL TRACK INSERT
6063-T6
-
4
FY205
AS REQD.
MOV. FRAME JAMB
6063-T6
-
5
FY101
AS REQD.
FIXED FRAME JAMB
6063-T6
-
6
FY104
1/ VENT
FIXED MTG. RAIL
6063-T6
-
7
FY105
1/ VENT
VENT INTERLOCK
6063-T6
-
B
FY206
1/ VENT
JAMB STILE
6063-T6
-
9
FY107
2/ VENT
TOP AND BOTTOM RAIL
6063-T6
-
10
FY108
AS REQD.
GLAZING BEAD (LAM. GLASS)
6063-T6
-
10A
FY110
AS REQD.
GLAZING BEAD (INSUL. LAM. GLASS)
6063-T8
-
11
-
AS REQD.
REINFORCING BAR
STEEL
-
12
-
AS READ.
REINFORCING BAR
STEEL
-
13
FY204
AS RTEQD.
ADD -ON SILL RISER
6063-T6
USE AS REQD.
14
FY208
4/ VENT
ROLLER HOUSING & GUIDE
CELCON
-
15
FY209
2/ VENT
ROLLER
BRASS
-
16
FY210
2/ VENT
ROLLER PIN
ST. STEEL
-
17
#B X 1"
AS REQD.
FRAME/VENT ASSEMBLY SCREWS
CRS
P.H. SMS
18
#B X 3"
2/ VENT
FIX. RAIL SILL SCREWS (SILL END)
CRS
P.H. SMS
19
W23181
AS REQD.
FIN SEAL WSTRIPPING
-
ULTRAFAB
20
Q300T190
AS REQD.
BULB SEAL
Q-LON
SCHLEGEL
21
E207
AS REQD.
BULB SEAL
SANTOPRENE
ULTRAFAB, DUROMETER 65±5
22
E203
AS REQD.
GLAZING BEAD BULB
SANTOPRENE
ULTRAFAB, DUROMETER 65±5
23
FLB-50
AS REQD.
GLASS SPACER
SILICONE
FRANK LOWE
24
SL203P
2/ VENT
SWEEP LATCH
-
SULLIVAN & ASSOC.
25
#8 X 1/8"
2/ LATCH
LATCH INST. SCREW
ST. STEEL
OH SMS
26
WA2L
2/ WDW.
WEEP VALVE
-
PREFERRED ENG. PRODUCTS
27
-
1/ VENT
5/16" BOX SCREEN
-
OPTIONAL
28
FY120
-
FLUSH FRAME ADAPTER
6063-T6
OPTIONAL • 1
29
-
2/ LITE
SETTING BLOCK
EPDM
DUROMETER 80±5 SHORE A
PRODUCT REVISED
as complying with the Florida
Building Code_
Acceptance No
Expiation Date- q
By $:44nq Zhop
Etitk Ptg
•
•
• • • •
•
• • • •
• 1
•• ••
•
•
1
• 1
• •
• • 1
•• 1
c
a
0
1'
it;
C
0
0)
.5
L
•
•
c
0
0.
U
N
•
••
•
Qi
O
0
M
0
t
P4
tri
0
h
ai
0
O
C
U
w
N
0 O
•
a
0
C
drawing no.
W09 —12
sheet 6 of 7
•
•
FRAME TOP CORNER
VENT TOP/BOTTOM CORNERS
FRAME BOTTOM CORNER
FIXED MTG. RAIL CORNER
PRODUCT REVISED)
as cc a1!piy ag with the Florida
Building Code
Acceptance No ] 1 102.23
Expiyataun Date _0.5 J'j'i lib Pi
BY S:ar Za 110
Miami Dade Proc sot Control
• •
• • •
•• •
•
• • • •
•
• • •
•
•
•• ••
•
• • •
• •
• •
• • •
•• •
��'' �GE1dSF • �
m
tao
el 14'
CL le
� N
ag
0042
gqg
oLo_gri
• O
IL11-
Q Eo2
0
W
N_
rn
0
ZJ
a
4)
L
FAX (305) 885-5902
•• •
•
•
0
a
U
N
N
••
•
•
N
Z
d
n
O
N
O
u�
O
N
Of
O
V
0
W
ti
c
a
a
i
r
v
drawing no.
W09-12
(sheet 7 of 7