Loading...
RF-18-2315Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Project Address mit Parcel Number tssee Date: 81 012018 Permit NO. RF-8-18-2315 Permit Type: Roof Work Classification: Tile Permit Status: APPROVED Expiration: 02/26/2019 Applicant 117 NE 91 Street Miami Shores, FL 33138- 1132060133310 Block: Lot: TERE & SADRI MEDINA Owner Information Address Phone Cell TERE & SADRI MEDINA 117 NE 91 Street MIAMI SHORES FL 33138- (786)486-6251 117 NE 91 Street MIAMI SHORES FL 33138- Contractor(s) AMADOR ROOFING CORP Phone Cell Phone (305)527-5524 Valuation: $ 17,365.45 Total Sq Feet: 1569 Type of Work: Re Roof Additional Info: RE -ROOF TILE Classification: Residential Scanning: 3 Fees Due Bond Type - Contractors Bond CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $500.00 $10.80 $4.13 $2.75 $3.60 $275.00 $9.00 $14.40 $819.68 Pay Date Pay Type Invoice # RF-8-18-68725 08/30/2018 Check #: 1265 $ 819.68 ^ $ 0.00 Bond #: 3874 Amt Paid Amt Due Available Inspections: Inspection Type: Up Lift Report Tin Cap Final Roof Tile In Progress Review Roof Renailing Affidavit Cap Sheet In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certii - I the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. re, I thorize the ove-named contractor to do the work stated. Authorize,/-ignature: Owner / Applicant / Contractor // Agent August 30, 2018 Date Building Department Copy August 30, 2018 1 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Ave, Miami Shores, Florida 33138 Tel: 305-795-2204 Fax: 305-756-8972 Inspection Number: INSP-001516-2018 Permit Number: RF-8-18-2315 Scheduled Inspection Date: November 08, 2018 Inspector: Naranjo, Ismael Owner: TERE & SADRI MEDINA Address: 117 NE 91 ST Project: Miami Shores , FL 33138 Contractor: AMADOR ROOFING CORP RICHARD AMADOR Permit Type: Roof Inspection Type: Roofing Final Work Classification: Tile Phone Number: 7864866261 Parcel Number: 1132060133310 Phone Number: 3055275524 Building Department Comments RE -ROOF TILE Checklist Item General Comments Passed Passed False Failed Correction Needed Re -Inspection Fee No Additional Inspections can be scheduled until re -inspection feeds paid. Comments Tile underlayment may not be expose at valleys. Provide open valley with mortar. Inspector Comments November 87, 2018 For Inspections please call: 305-762-4949 Page 18 of 38 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC El ROOFING ❑ REVISION ❑ EXTENSION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 RECEIVED AUG 3 0 2018 C FFBCr 20 P Master Permit No. IC, t— le - ? ej IS Sub Permit No. ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION CONTRACTOR JOB ADDRESS: I I -1 (\(E RI Sree+ City: Miami Shores County: Folio/Parcel#: 11. 3DU(7.013 • 3310 Occupancy Type: Load: Construction Type: Miami Dade Zip: ❑ RENEWAL ❑ SHOP DRAWINGS Is the Building Historically Designated: Yes NO Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Tere Medina. Address:111 NE 611 Sired - City: M I Qii7i I i State: FL Phone#: Zip3313o Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: Amactor Pow o3 Address:1331 N1N 54 Ttfd City: M I Qih i Imo. co,.1 State: Qualifier Name: R1rd ArrladOr" Corp. Phone#:1Ro •3q(• IS2lo 12e,\( • 9-2 Cv LOCI - 9-8 I L-( Zip: 33110(o Phone#:7S(o 1I • 1 State Certification or Registration #: CL�C 133I0(9q Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ 11,305. 45 Square/Linear Foo . - • ork: 1 5 q Type of Work: ❑ Additionn❑-Alteration. New Description of Work: 12 e - n Demolition Specify color of color thru tile: C,cID txiST Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding,Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signatur Signature ( OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this I51- day of L1jS`f , 20 IS , by Tere Mec le , who is personally known to me or who has produced FL 1�L identification and who did take an oath. NOTA • UBLIC: Si Print: Seal: rala as MY COMMISSION k FF970070 EXPIRES March 10, 2020 FIorNlaNrxl••ySorvraf. rorr APPROVED BY St day of A LUi" , 20 I8 , by cfQrct Ant Or, who is personally known to me or who has produced as identification and who did take an oath. NOTARk' DUBLIC: Sig'I!!Ii Print: Seal: Plans Examiner i ICA K KANE E MY COMMISSION # FF970070 of "P`EXPIRES March 10, 2020 140/)1Wt-0'53 FMxrlallotwySorvrr, cur Zoning (Revised02/24/2014) Structural Review Clerk 8/30/2018 Property Search Application - Miami -Dade County Summary Report Property Information Folio: 11-3206-013-3310 Property Address: 117 NE 91 ST Miami Shores, FL 33138-2809 Owner TERE MEDINA SADRI MEDINA Mailing Address 117 NE 91 ST MIAMI SHORES, FL 33138 USA PA Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds / Baths / Half 3/2/0 Floors 2 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 1,897 Sq.Ft Lot Size 9,825 Sq.Ft Year Built 1938 Assessment Information Year 2018 2017 2016 Land Value $245,690 $245,690 $245,690 Building Value $132,031 $132,031 $132,031 XF Value $1,246 $1,265 Market Value ] $378,967. $378,986 Assessed Value $322,405 $315,774 $309,280 Benefits Information Benefit Type 2018 2017 2016 Save Our Homes Cap Assessment Reduction $56,544 $63,193 $69,706 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 1 AMD PB 10-70 LOT 17 &W1/2 OF LOT 18 BLK 24 LOT SIZE 75.000 X 131 OR 13302-1679 0687 1 Generated On : 8/30/2018 Taxable Value Information 20181 20171 2016 County Exemption Value $50,000 $50,000 $50,000 Taxable Value $272,405 $265,774 $259,280 School Board Exemption Value $25,000 $25,000 $25,000 Taxable Value $297,405 $290,774 $284,280 City Exemption Value $50,000 $50,000 $50,000 Taxable Value $272,405 $265,774 $259,280 Regional Exemption Value $50,000 $272,405 $50,000 $50,000 Taxable Value $265,774 $259.280 Sales Information Previous Sale Price OR Book - Page Qualification Description 06/26/2014 $425,000 29209-3268 Qual by exam of deed 01/14/2014 $100 28990-4181 Corrective, tax or QCD; min consideration 06/01/1987 $97,000 13302-1679 Sales which are qualified 06/01/1982 $98,500 11471-1066 Other disqualified The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 •..., Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 • • • : • • • Asphaltic Shingles A,B,D 1,2,4,5,6,7 .... •.... .•. . -. .. Concrete or Clay Tile A,B,D,E 1.2.3.4.5,6,i .. . .. . : . .... • • Metal Roofs A,B,D 1,2,3,4,5,6,r • -: . Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 - • •' : • • •. • • • • Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Notice of Acceptance: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS 128 4. Other Component Notice of Acceptances 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Re -Roofing Only) 7. Any Required Roof Testing/Calculation Documentation . . . Florida Building Code 6th Edition (2017) Nigh-Veiodty Hurricane Zone Uniform Permit Application For Sgction A Menem! irdomudioni Master Ferntit No. Contractor's AMADOR ROOFING !lame Job Address 117 NE 91 ST O Low Slope O Asphaltic Shingles ROOF CATEGORY O Mechanically Fastened Tile Mortar/Adhesive Set:Tiles O Metal Panel/Shingles 0 Wood &tingles/Shakes O Prescriptive SUR-RAS 150 ROOF TYPE 1 1 1 1 1 1 1 1 1 1 1 1 0000 • • O New roof 0 Repair 0 Maintenance X Reroofing • . : Recovevris •••• • • • ROOF SYSTEM INFORMATION R E C E Roof Area (SF) QSteep Sloped Roof AREA (SSF) 1569 Total (SF) .1569 • • • • • .... . .. • • • AUG g 0 1018 Section B (Roof Plan) • • : ••••11.. Plan: illustrate all levels and sections, roof drains, sag:vela, overflow scup eis and drains trielude dirnen- • ns • • and levels. clearly identify trenensions of elevated pressure zones and tocaton. . • • i• N/A' Per.0*,ottAisst. WCPM; NA' • • .• •••••• 44,04.160. S•rt.e..*: .. • . • • 0 ZDN/NSDEPT F- w 0 _1 oUeJsCTY0QCWPLANCE rr) z 0 cc 0 20 27 32 19 13 9 12 25 FLAT N/A 20 FLORIDA BUILDING CODE - BUILDING. 6th EDITION (2017; 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ft Miarni Shores Village Building. Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: S? 112..clr• 10050 NE 2nd Ave ,,,, • •• • ▪ . Miami. Shores, FI 33138 • • • . • • . • . • • ••• • Re: Owner's Name: Mee Meth ()CI• •• • • Property Address: 11-1 NE 1 I Streefi I i i am; Shores , FL 3311F•` • • • • • • •• Roofing Permit Number: •••••• ••:••• Dear Building Official: ••• • • • • 1 Teri. Medi nn certify that I am not required to retrofit the rood 4o wall cone eetiogs of nay • •• • building because: X The just valuation for thestructure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Signature Tere Mccl i nG . Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this 15+ day of Al Uq US# , 2>01 1 Notary Public, Sate of Florida at Larg %' � I • Whenthe just valuation of the structure for.pu ad valorem taxation is equal to JESSICA K KANE # FF970070 EXPIRES March 70. 2020 trusted with FBC nor a 1994 SFBC. Then you must provide a buildng application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 SECTION 1524 HIGH VELOCITY HURRICANE ZONES - REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 2. enaiiing wood decks: When replacing roofing, the existing wood roof deck preynhve to be r+ir►a'led in accordance with the current provisions of Section R4403. (The roof de k is usu2fl5P• concealed prior to removing the existing roof system). •• • • • •• •• • . • • • Exposed Ceiling: Exposed, open beam ceilings are where the: urtre.,iiide of th4 rdcfjcking. • • • • can `tie viewed from' below. The owner may wish to maintain the architectural appeaoance;.therefore, ' • roofing nail penetration of the underside.of the decking may not be acceptable. hiss rovides 4he eption of maintaining the appearance. .' • • •. . 6. .Overflow scuppers :(wall :outlets): It is required that rainwater flows off so that'tbgtpof is n•t v=rloaded from a buildup of water: Perimeter/edge wall or other roof extension may block, this disc arge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 004» Owner/Agents; Signature Date Contractor Signature Date 111 NE GI Stet Property Address Miami shores, a 33138 Revised on 7/9/2009 LD;07/01/2015; Permit Number • . Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: BORAL ROOFING LLC. Notice of Acceptance Number: 16-0711.01 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): P1: 39.1 P2: -68.1 P3: 100.7 Maximum Design Pressure 29.3 (2 SMALL PADDY) (From the NOA Specific System): • • • • • • .. Method of tile attachment: ICP Adhesives Polyset two-componerIffoe n • ••.. .. • • • . Roof Slope: 3 :12 ...• . . .•• .. Steep Sloped Roof System Description. Deck Type: . • .• .. . •. . • • • • . • .• • •• . •• . . •• . • • • • • . • . • • • • .. • 5/8 PLYWOOD ype Underlayment: nsuiation: Ridge Ventilation? N/A ASTMD 226 TYPE II # 30 N/A ire Barrier. N/A astener Type & Spacing: 1 1/4" R/S & 5/8 TINCAP 6"LAPS 2 ROWS 12" O.0 FIELD dhesive Type: Mean Roof Height: 10' SELF -ADHERED BACKED NAILER maximum 6" o.c. W/TINCAP & 1 1/4 ype Cap Sheet: BORAL TILE SEAL oof Covering: BARCELONA 900 Type & Size Drip dge: 3X3 GALV. 26 GAUGE 1 1/4" R/S 4" O.0 Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compared the values for Mrwith the values from Mt. If the Mt values are greater than or equal to the Mr values, for each area of the root, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (pi: 39.1. z .301 .11.76 ) - Mg: 7.00 3 me 4.76 NOA Mr 29.3 (p2: -68.1. z a .301 = 20.49 ) - Mg: 7.00 = Me2 13.49 NOA ilk 29 3 0,3; 100.74 .301 = 30.31. ) - Mg: 7.00 ., 23____ _31 NOA Mr 99 3 Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance (Mr) From Table Below NOA 111i Mr Required Moment Resistance* • • • • • • • • . . Mean Roof Height •. • • • • • — Roof Slope 212l 34A 36.5 38.2 • • •3g'P 42.2 3:12 32.2 34.4 36.0 .' '13, :' •39* ' 4:12 30r4 32.2 33.8 311 1'1% • •. 5:12 28A 30.1 31.6 •' eV, • • .j1 6:12 26.4 28.0 29A . • 0.10.4 32.4 7:12 24.4 25.9 27.1 • 16l . 340 *Must be used ht conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compared the values for F' with the valves for F,. If the F' values are greater than or equal to the F, values, for each area of the roof, then the tile attachment method is acceptable. • • ••� • • ••• • .• . • • • . . .. • • Method 3 "Uplift Based Tile Calculations Per RAS 127" (Pi : z l: a z w: _ ) — W: z cos 8: = Fry: NOA F' (P2: x = w: )-W: zcos 9: = Fr2: NOA F' (P3 : z l: = z w: = ) - W: z cos 0: = Fri: NOA F' Where to Obtain Information Description Symbol Where to find Design Pressure P 1 orP2 or P3 RAS 127 Table 1 or by an a ngineeting analysis prepnrod by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope a Job Site Aerodynamic Multiplier a, NOA Restoring Moment due to Gravity Ma NOA Attachment Resistance Mr NOA Required Moment Resistance Mr Calculated Minimum Attachment Resistance F NOA Required Uplift Resistance Fr Calculated ATile Weight W NOA Tile Dimensions 1= length w= width NOA All calculations must be submitted to the Building Official at the time ofpermit application. MIAN DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.¢ov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Condo: C: ection (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve tlttepgh= to havv.thjs product or material tested for quality assurance purposes. If this product or material fails to perf .ree in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or • suspend the use of such product or material within their jurisdiction. RER reserves the right Id Ittpke thts%cdeptanc8, if it is determined by Miami -Dade County Product Control Section that this product or materia1'1'a 1s to meet fie requirements of the applicable building code. . . : .". This product is approved as described herein, and has been designed to comply with the Florid,41341ding Code including the High Velocity Hurricane Zone of the Florida Building Code. •• • • • DESCRIPTION: Barcelona 900 Concrete Roof Tile • • • •. .• . • •. • • .. .. . • . . • • .• LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.12-0222.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 1 of 7 Barcelona 900 Trim Pieces ROOFING ASSEMBLY APPROVAL Category: Sub -Category: Material: Roofing Roofing Tiles Concrete 1. SCOPE This approves a roofing system using Barcelona 900 Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product • • • • • . Applicant Dimensions Specifications Dwscrii3tion • • • • . • •• . Length = 17" TAS 112 High profile, interloekicpone-piaoe,:S' shaped,.:. Width = 13" Type — la high-pressure extrudttheoacrete roof tile • %" thick equipped with three J alrliples. f br d?i ct detk or battened nail -on, mecihanically fastened, . . mortar set or adhesiygsgtapplicaiir. •. TAS-112 Accessory trim, boostectBsaircelonconcrete. roof pieces for use 4 hips„rakesridges and • valley terminations maaufActure 1 reach tire profile. Length: varies Width: varies varying thickness 2.1 MANUFACTURING LOCATION 2.1.1. Lake Wales, FL 2.2 SUBMITTED EVIDENCE: Test Agency Redland Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies Test Identifier 7161-03 Appendix III 7161-03 Appendix II P0402 Letter Dated Aug. 1, 1994 P0631-01 Test Name/Report Static Uplift Testing TAS 102 & TAS 102(A) Wind Tunnel Testing TAS 108(Nail-On) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Date Dec. 1991 Dec. 1991 Sept. 1993 Aug. 1994 July 1994 • • NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 2 of 7 • . Professional Service Industries, Inc. IC-1320-94 Physical Properties Feb. 1995 TAS 112 The Center for Applied Engineering, Inc. 25-7688-3 TAS 101 (Adhesive Set) June 1996 25-7688-10 TAS 101 (Mortar Set) July 1996 The Center for Applied Engineering, Inc. 25-7688-5 Static Uplift Testing June 1996 TAS 102 (3" Headlap, Nails, Direct Deck, New Construction) The Center for Applied Engineering, Inc. 25-7688-4 Static Uplift Testing June 1996 TAS 102 (4" Headlap, Nails, Clips) Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services 520191-2-1 TAS 101 March 1999 Walker Engineering, Inc. Calculations Aerodynamic Multiplier 09/01/16 •..• Walker Engineering, Inc. Evaluation Restoring Moments Dtw to '. A.901/16 Calculations Gravity . • • • • .. • • American Test Lab of South Florida RT0617.03-16 TAS 112 • ' 906,29/16 •••• •.. • • •• • • 3. LIMITATIONS: •�:': ' • •• • • • 3.1 Fire classification is not part of this acceptance. • • • • • • • • 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance wittilAS 106 mad required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory tttp&rfbrm quarterly test jti • • •' accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Department of•R.gtitratory and Economic Development — Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 3 of 7 4. INSTALLATION 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length -I (ft) Width-w (ft) Barcelona 900 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers - A (ft3) Tile Profile A (ft3) Batten Application A (ft3) Direct Deck Application Barcelona 900 0.286 :0.fl,1 -••••- •••, •• • •.• Table 3: Restoring Moments due to Gravity - Mg (ft-Ibf) • •. • • •••. Tile Profile 2":12" 3":12" 4":12" 5":12" 6"11.2'•' . . : Pk.1'2" or.... : ,grater • • • • Barcelona 900 Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens, : l• aGect DeCk Batteps Direct De.• 6.42 6.19 7.07 6.19 7.00 6.19 6.90 6.06 6.76 5.92 • 6 60 %.76'• •• • •• • Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-lbf) •' ••• for Mechanically Attached Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct. Deck (min. 19/32" plywood) Battens Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4 1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 #8 Screw 20.7 20.7 18.1 2 #8 Screw 43.2 43.2 29.8 1-10d Smooth or Screw Shank Nail (Field Clip) 23.1 23.1 19.0 1-10d Smooth. or Screw Shank Nail (Eave Clip) 29.3 29.3 24.0 2-10d Smooth or • Screw Shank Nails (Field Clip) 27.6 27.6 38.6 2-1 od Srnooth or Screw Shank Nails (Eave Clip) 38.1 38.1 41.8 NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 4 of 7 •• • • • •• • • .• • • • • • Table 5: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Mechanically Attached Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Barcelona 900 2-10d Ring Shank Nails' 33.1 48.1 45.2 1 Installation with a 4" tile headlap and fasteners are located a min. of 2%z" from head of tile. Table 6: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barcelona 900 Adhesive' 29,3'••• 1 See manufactures component approval for installation requirements. • .•. •••• ••• 2 TILE BONDTM Roof Tile Adhesive; Average weight per paddy 10.7 grams. .".•. ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160; Average weight per pacici $•grams. . "" Table 7: Attachment Resistance Expressed as a Moment - Mf'(itripf) •• •'.. •• for Single Paddy Adhesive Set Systems • •• • •• • • • ..., ..: I Tile Profile Tile Application J% Lwjpum Attachment •• • Resistance • • •. Barcelona 900 ICP Adhesives Polyset AH-160 :•••�� 66'5� •••. ICP Adhesives Polyset AH-160 • 38.1;•.• • 3 Large paddyplacement of 63 grams of ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160. 4 Medium paddyplacement of 24 grams of lCP Adhesives and Sealants, Inc.'s ICP Adhesives Polvset AH-160. Table 8: Attachment Resistance Expressed as a Moment - Mf (ft-ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Barcelona 900 Mortar Set5 24.5 6 See specific mortar manufacturers Notice of Acceptance NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date; 10/27/16 Page 5 of 7 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". LABEL FOR BARCELONA 900 TILE (LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS • ... , • . . . 6.1 Application for building permit shall be accompanied by copies of the following~ • ; •; • •: • • 6.1.1 This Notice of Acceptance. . . 6.1.2 Any other documents required by the Building Official or applicable bu•ik4ing.code in order to • . properly evaluate the installation of this system. • • • • • • • . .. . . • . . .. .. •... • • . • .• • . . • . • •• • •• • . • .• NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 6 of 7 PROFILE DRAWING NAIL HOLES 17* UNDERLOCK OVERLOCK BARCELONA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE ®; ;s_tYLL.;_,d.�� APPROVED 13" 35/8m .... .... • . ... . .. . . ..• . • . • . .... .. . • ▪ .. . .... . • .. • .. . . . . . .. .. ..... • .. . • • • • • • • • • •• ▪ . ..• .. • • • • . .. . NOA No.: 16-0711.01 Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 7 of 7 MIAMIDADE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Boral Roofing LLC. 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.eov/economv This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Contrd Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve le rrAt to hava tl3is product or material tested for quality assurance purposes. If this product or material fails to pdffortn in tileageepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, mddif j', or suspend the use of such product or material within their jurisdiction. RER reserves the right o awoke this acoeptanoe, • • • if it is determined by Miami -Dade County Product Control Section that this product or mate?iajfails to rteettlte requirements of the applicable building code. • • • This product is approved as described herein, and has been designed to comply with the Florida•Buildingde including the High Velocity Hurricane Zone of the Florida Building Code. • •• DESCRIPTION: BORAL TileSeal • • • • • • • • • •• • • • • ••• • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. � • • • • • • •• • • • ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This new NOA consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 1 of 4 ROOFING COMPONENT APPROVAL Category: Sub -Category: Material: Roofing Underlayment SBS PRODUCTS DESCRIPTION: Product BORAL TileSeal Dimensions 36" x 36' rolls 36" x 72' rolls Boral Citadel Plus 36" x 72' rolls MANUFACTURIGN LOCATION: 1. Brentwood, NH. 2. Houston, TX. EVIDENCE SUBMITTED: Test Agency PRI Construction Materials Technologies, LLC. Trinity ERD Test Specification TAS 103 ASTM D1970 ASTM D1970 Test Identifier OCF-356-02-04 OCF-356-02-02 OCF-356-02-01 OCF-424-02-04 OCF-424-02-01 OCF-424-02-03 BRLRF-SC16810.11.17 Product Description SBS self -adhering asphalt sheet material with a white glass re -enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. SBS self -adhering asphalt sheet material with a poly film -facer; for use as a mid-Alyetittl,erlayment in sloped roof assemblies. • . • • • • • .... . . .... . . .. .. • . • Test Name/RepQrt . • • ASTM D1623 .• TAS 103 ASTM D1970 ASTM D1623 ASTM D1970 TAS 103 ASTM D 1876 .• . . • . ..• • ..• • .• • .• • .. • . •.... • • • . • • • • • • • Date • • „• Q9/25/18 07/24/18 07/26/18 07/25/18 07/25/18 07/25/18 11/28/17 NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 2 of 4 • • APPROVED ASSEMBLIES: Deck Type 1: Deck Description: System E(1): Base Sheet: Ply Sheet (Optional): Membrane: Surfacing: Wood, non -insulated I5/32" or greater plywood or wood plank Anchor sheet mechanically fastened deck, membrane adhered. One or more plies of ASTM D226 Type II or ASTM D2626 with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Apply one layer of Boral Citadel Plus over Base sheet as per current approval. One or more plies of BORAL TileSeal Underlayment with a minimum 3" head lap and minimum 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the metnbrape is applied. Vertical strapping of the roof with BORAL TileSeal Undei'laAcnt is Wei table. iL1•1t •; • end laps and laps without black selvage area shall be sealed under lap nssng an Sn.modified '. mastic. • . Note: When used in Tile roof systems BORAL TileSeal Underlaymeat sliall be:baoianailed.to.•.. • deck with approved annular ring shank nails and tin caps at a maxiititi it•l " o.c: tits side laps. No nails or tin caps shall be exposed. • • • • . . . Approved for Adhered Roof Tile using TILE BOND or AH-160, Kechapically pasterred Ropf Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle a�s�mblies•.. •.• • • • . • NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 3 of 4 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. • • • • •. 8. Tiles shall be stored on battens on roof pitches greater than 6:12". • • • • • • • •• • • 9. BORAL TileSeal underlayment may be used with any approved roof covering Notice af•AAeeptance•listing • BORAL TileSeal underlayment as a component part of an assembly in the Notice of ACeBhce. If BORAL • TileSeal underlayment is not listed, a request may be made to the Authority Having Juni'sdiction (AN.1i) dr.the • • Miami -Dade County Product Control Department for approval provided that appropriate • • provided to detail compatibility of the products, wind uplift resistance, and fire testing tg. •.:.. • 10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loQmQegking panels. Sweep • the deck thoroughly to remove any dust and debris prior to application. • 11. When applying the membrane in the valley, start at the low point and work to the high Iflt,3ollinglbe jnembr�ne• •; ipj from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment shall be applied over the underlayment, and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below A'.NKC EDI END OF THIS ACCEPTANCE NOA No.: 18-0502.03 Expiration Date: 08/02/23 Approval Date: 08/02/18 Page 4 of 4 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) ICP Adhesives and Sealants, Inc. 12505 NW 44th Street Coral Springs, FL. 33065 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 www.miamidade.gov/economv SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted vlanner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,:modiiy, or sf liehd the ¶i' : • of such product or material within their jurisdiction. RER reserves the right to revoke.this accaptaraco, if it is'. determined by Miami -Dade County Product Control Section that this product or material fajls.v.tneet the rgquiremgnts • of the applicable building code.• • •• . . •. . • This product is approved as described herein, and has been designed to comply with ttit'Florida•Butltling Catlr•. including the High Velocity Hurricane Zone of the Florida Building Code. . . •• . • DESCRIPTION: ICP Adhesives Polyset® AH-160 • • •. . • • • . • •. . • • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, statt i2d'following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Specifications Product Description .... • ICP Adhesives N/A TAS 101 Two component pglyuwethane •froml adheive• • • Polyset®AH-160 ICP Adhesives Foam N/A Dispensing Equipment.:.. • Dispenser RTF1000 • • • ICP Adhesives ProPack® N/A Dispensing Equipment"' ' •• . 30 & 100 .. . .. . • .. .. . • . PRODUCTS MANUFACTURED BY OTHERS: . . .. .. • • . • • • .• • .. • • • ...• • • • • Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which iisr'aitkhment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 Results 1.6 lbs./ft.3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft2 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 • EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier #94-060 257818-1 PA 25-743 8-3 25-7438-4 25-7438-7 25-7492 NB-589-631 9637-92 01-6743-011 01-6739-062b[1] 7050.02.96-1 P36700.04.12 P39740.02.12 528454-2-1 528454-9-1 528454-10-1 520109-1 520109-2 520109-3 520109-6 520109-7 520191-1 520109-2-1 Test Name/Report TAS 101 TAS 101 SSTD 11-93 SSTD 11-93 SSTD 11-93 ASTM D 1623 ASTM E 108 ASTM E 108 ASTM E 84 TAS 114 ASTM D 1623 TAS 101 TAS 123 TAS 101 TAS 101 • .. .. . . .... . . .... . . .. •. • . . • . • • • • . ..• Date 04/08/94 12/16/96 10/25/95 11/02/95 12/12/95 02/01/94 04/30/93 11/16/94 .01N46(95 .... M/44496 U4/418/12 .Q2/21/12 .. . • .. • •• 14/25/98 • • :898 • • • • • • . • • • • • TAS 101 03/02/99 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing. Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval. Date: 04/27/17 Page 3 of 11 • • INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160.shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component stall be mainine.between 1.0-1.15 (A): 1.0 (B). • • .. . •.. . . • 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenseai'RTP 1000 of 1CP Adhesives ProPack® 30. & 100 dispensing equipment only. • .... •• • 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. • •... 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minus i; ..ater ICIC eftnesives Polyset® AH-160 has been dispensed. . 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in actordaztce wigt1& • 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. • .. . .. . • . •..• • . • • • . . NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Area Minimum Paddy Gram Weight Eave Course - Flat, Low, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at head of tile 9-11 sq. inches at overlap 12 grams per paddy Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal edge) 20-25 sq. inches each. • bead •• • 17 grai•per bead • •.... • .. •. • •. • •• • • • • •• . . Two Piece Barrel (PanTile) Two Piece 65-70 inches • • sq.• • � • i4 grams under paa - - LABELING: .•.• •• •..• .. • •• . • • •• . • .. .. • . .•.. • 1• • • • • • All approved products listed herein shall be labeled and shall bear the imprint or identifiable ih%ittig of the • manufacturer's name or logo and following statement: "Miami -Dade County Product Control Apvroved'SoatKaMiathi• - Dade County Product Control Seal as shown below. • . •• • .•• BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. • •• NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. ... • Medium Profile / Double Pax file "" .. . .. . . . . • 1. Starting at the eave cowcown,:412ply a minjmum 2'; (50.8 mm) x 10" (254 mm),Y 1" (2S.4 nun) foam paddy onto the underlaymen positioned.as shows... under the pan portion df tt1ertjle cloge%t to.the overlock of the tile being s2t. • • • • . • 2. Continue in same manrjer. Insure agpmnemately.17 (109.7 cm2) — 23 (148.4 ,c,012),square Atcj1 adhesive • • contact with the underside of the tile.. • . • High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under: the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date:, 04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. • • • 3. Continue in same manner. krsurc approximately 10" .• (64.5 cm2) - 12 (77.4 cm2)44i e inch adhesive contact with the undersideof?1 a tile. • .... .. . •. .• •• •••••.• •. Medium Profile / Double Pap.TI• • •• • • • • • • 1. Starting at the eave course, apply a minimum 2" (54.8.:. mm) x 10" (254 mm) x 1'; (21.4•mm) foam paddy • • onto the underlayment positioned as shoeynder the • pan portion of the tile closest to the overloc'k of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown underthepan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. • •••• • .... • . . • .•• . •• . . 3. Continue in same mamier,iths.urg apprbXiiilately 17," • (109.7 cm2) - 19 (122.6 crxi)D9gt are inch adhesive . . contact with the undersidc,ef th tile. :•. • •••• • •• • • • •• • • • •• •• •••• • • •• • • • • • ••• • ••• . •• • • • • .• NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11