RC-17-2956Miami Shores Village
10050 N.E. 2nd Avenue NE
Miami Shores, FL 33138-0000
Phone: (305)795-2204
Project Address
P r lt..174 �12-17, -2956
Permit T pe Resid anti I Construction
INoncbassifc ition: Alteration
PertnitStatus: APPROVED
Issue oate::3/6/2018'
Expiration: 09/02/2018
Parcel Number
Applicant
551 NE 102 Street
Miami Shores, FL 33138-2454
1132060170980
Block: Lot:
CORY & LISA GITTNER
Owner Information
Address
Phone
CeII
CORY & LISA GITTNER
551 NE 102 Street
MIAMI SHORES FL 33138-2454
Contractor(s)
WILCON CO
Phone
(786)399-8855
CeII Phone
Valuation:
Total Sq Feet:
$ 30,000.00
250
Approved: In Review
Comments:
Date Approved: : In Review
Date Denied:
Type of Construction: NEW
Stories:
Front Setback:
Left Setback:
Bedrooms:
Plans Submitted: Yes
Certificate Date:
Bond Return :
CABINETS AND COUNTERTC
Occupancy: Single Family
Exterior:
Rear Setback:
Right Setback:
Bathrooms:
Certificate Status:
Additional Info:
Classification: Residential
Fees Due
Bond Type - Owners Bond
CCF
CO/CC Fee
DBPR Fee
DCA Fee
Education Surcharge
Notary Fee
Permit Fee
Plan Review Fee (Engineer)
Plan Review Fee (Engineer)
Scanning Fee
Technology Fee
Total:
Amount
$500.00
$18.00
$50.00
$13.50
$9.00
$6.00
$5.00
$900.00
$80.00
$120.00
$12.00
$24.00
$1,737.50
Pay Date Pay Type
Invoice # RC-12-17-65923
03/06/2018 Check #: 8099
12/15/2017 Check #: 8065
Bond #: 3680
Amt Paid Amt Due
$ 1,537.50 $ 200.00
$ 200.00 $ 0.00
Available Inspections:
Inspection Type:
Final PE Certification
Window Door Attachment
Framing
Insulation
Drywall Screw
Window and Door Buck
Fill Cells Columns
Review Electrical
Review Electrical
Review Electrical
Review Building
Review Building
Review Structural
Review Structural
Review Planning
Review Plumbing
Review Plumbing
Review Mechanical
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certi that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zo))ng. Futh;u . e I - uthorize the above -named contractor to do the work stated.
March 06, 2018
•,,. •,
Authorized Sig(tature.
/ Applicant / Contractor / Agent
Date
Building Department Copy
March 06, 2018
1
BUILDING
PERMIT APPLICATION
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
VFD
207
FBC 20MS44'
Master Permit No. n 2 / co
Sub Permit No.
BUILDING ❑ ELECTRIC ROOFING REVISION ❑ EXTENSION RENEWAL
• PLUMBING ❑ MECHANICAL PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS:
City: Miami Shores
Folio/Parcel#: - / / 32.00 O (7O' �O
Occupancy Type:
County: Miami Dade
Load: Construction Type:
Zip:
F7/ C
Is the Building Historically Designated: Yes NO r1—
Flood Zone:
BFE:
OWNER: Name (Fee Simple Titleholder): C O 12 G /T 7itier_ Phone#:
Address: S S1 VIE
C (�
City: U ` c A'- f t4-6 ✓L ki _5 State:
S 7 K,ErT
U ' L-
FFE:
Zip: 3 3 d
Tenant/Lessee Name: r 9 Phone#:
Email: GOjr1'� wt � d f'a 4-e. c-14 i a c 4 1 l✓D wl
CONTRACTOR: Company Name: t() 1 Z Coit) .
Address: 1113-4=. A/C c %1A,'-e . ( O
City: 01 1 D-i--(I 5 1 S State: 0
Qualifier Name:
(il it 1 i 4,,N) Crw 2 //
State Certification or Registration #: C /cJ-� 4Z Certificate of Competency #:
DESIGNER: Architect/Engineer. f� O FN (9 /Al J�6z 1, y Phone#:
(�j I , l ��y T ^Tj p
Address: [, t� l N ui q^^ / ` G l City: J"L. 4N r -T (D dI State: FL Zip: `3 P4
Value of Work for this Permit: $ P?V/ OW - 03 Square/Linear Footage of Work:
Type of Work: ❑ Addition Ii Alteration n New // ❑Repair/Replace ❑ Demolition
L) GC c
Description of Work: ,/ /1► 11 4 L ., r\Te p`/ 'Psy 12(�v vc w a /, .1:70bNie'l
Phone#:
/3q-
Phone#:
Specify color of color thru tile:
Submittal Fee
Scanning Fee $
Permit Fee $ AM. Q CCF $ 'CO CO/CC $g) '
Radon Fee $ 1 CAM DBPR $ ( . 50 Notary $ 5 •
Technology Fee $ ' ,,�
Structural Reviews $ S6 . Q
Training/Education Fee $ 6 Double Fee $
Bond $ 6
(Revised02/24/2014)
TOTAL FEE NOW DUE $ OS9 • JV
(-03T.3O
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City, State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be'delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved a a reinspection fee will be charged.
Signature
OWNER or AGENT
The foregoing instrument was acknowledged before me this
day of/i����C
C�U C ( /fit ` " who is personally known to
me or who has produced
i
identification and who did take an oath.
NOTARY PUBLIC:
‘ Old.4p3
•Pint: ^'v°�y :.
�, 4�a .�,
s
zr
, °<s�93/e . •o
'' ' • .0446944## R�,ks**********
APPROVED BY
(Revised02/24/2014)
_(4
VOL_ as
•
******************************************************************
The foregoing instrument was acknowledged before me this
, 20 (7 , by I day of 20 \� by
Cal U.I1C `1 Qi12-1.3-;., who is personally known to
me or who has produced L 1Pf2-(2--
identification and who did take an oath.
NOTARY PUBL
Sign:
Print:
Seal:
roe Notary Public State of Florida .(
Sindia Alvarez j.
Sc. ca My Commission FF 156750 1(
'4aFaoQ Expires09/03/2018 {L
Plans Examiner Zoning
Structural Review
Clerk
Property Search Application - Miami -Dade County
Page 1 of 2
Summary Report
Property Information
Folio:
11-3206-017-0980
Property Address:
551 NE 102 ST
Miami Shores, FL 33138-2454
Owner
CORY GITTNER &W
LISA B GITTNER
Mailing Address
551 NE 102 ST
MIAMI SHORES, FL 33138-2454
PA Primary Zone
1000 SGL FAMILY - 2101-2300 SQ
Primary Land Use
0101 RESIDENTIAL - SINGLE
FAMILY : 1 UNIT
Beds / Baths / Half
5/3/1
Floors
2
Living Units
1
Actual Area
Sq.Ft
Living Area
Sq.Ft
Adjusted Area
3,345 Sq.Ft
Lot Size
9,225 Sq.Ft
Year Built
1926
Assessment Information
Year
2017
2016
2015
Land Value
$276,617
$230,638
$221,738
Building Value
$212,950
$214,196
$215,442
XF Value
$636
$636
$516
Market Value
$490,203
$445,470
$437,696
Assessed Value
$284,946
$279,086
$277,146
Benefits Information
Benefit
Type
2017
2016
2015
Save Our Homes
Cap
Assessment
Reduction
$205,257
$166,384
$160,550
Homestead
Exemption
$25,000
$25,000
$25,000
Second
Homestead
Exemption
$25,000
$25,000
$25,000
Note: Not all benefits are applicable to all Taxable Values (i.e. County,
School Board, City, Regional).
Short Legal Description
MIAMI SHORES SEC 4 AMD PLAT
PB 15-14
LOT 19 & W1/2 LOT 20 BLK 93
LOT SIZE 75.000 X 123
OR 16041-0259 0893 1
Generated On : 12/15/2017
Taxable Value Information
2017
2016,2015
County
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$234,946
$229,086
$227,146
School Board
Exemption Value
$25,000
$25,000
$25,000
Taxable Value
$259,946
$254,086
$252,146
City
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$234,946
$229,086
$227,146
Regional
Exemption Value
$50,000
$50,000
$50,000
Taxable Value
$234,946
$229,086
$227,146
Sales Information
Previous
Sale
Price
OR Book -
Pa a
9
Qualification Description
06/01/2004
$0
22397-
2017
Sales which are disqualified as a result
of examination of the deed
08/01/1993
$100,000
16041
0259
Sales which are qualified
The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser
and Miami -Dade County assumes no liability. see full disclaimer and User Agreement at htto://www.miamidade.00v/info/disclaimer.aso
http://www.miamidade.gov/propertysearch/ 12/15/2017
IN &L INi
GENERAL CONTRACTOR
CONSTRUCTION MANAGEMENT
LICENSED & INSURED
CGC# 151264X
WIWAM CRUZ
9686 NE 9TN AVE RS.
UMW SNORES r . ,8196
OESISN-SUILD
Cat. 786-899.8859
OM= 306 4869988
wCRUZ$9@NOTMAILCO;
State of no/Lre/1--
County of Dade
Before me this day personally appeared_ 11111 /LCU4.- who, bed duly Skvotn, deposes and says:
That he or she will be the only person wowing on #t ro�eCt Ei l /�. ' /02 .
&/'
Sworn to (or affirmed) and subscribed before me this° day of 4ia&tl< ,234, by
`t/t//rn 1 PAtv/_
Penally Know
Or produced Identification
Type of Identification proms
Print, type or stamp of Ivry
Notary Public State of Ronda
} Siftdia Alvirez
Q¢ My Commission'
}�` 0 %042 Expires Oa/031201 s
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Notice to Owner — Workers' Compensation Insurance Exemption
Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat. § 440.05
allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to
obtaining a building permit. Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure:
An employer in the construction industry who employs one or more part-time or full -tithe
employees, including the owner, must obtain workers' compensation coverage. Corporate officers
or members of a limited liability company (LLC) in the construction industry may elect to be
exempt if:
1. The officer owns at least 10 percent of the stock of the corporation, or in the case of
an LLC, a statement attesting to the minimum 10 percent ownership;
2. The officer is listed as an officer of the corporation in the records of the Florida
Department of State, Division of Corporations; and
3. The corporation is registered and listed as active with the Florida Department of
State, Division of Corporations.
No more than three corporate officers per corporation or limited liability company members are
allowed to be exempt. Construction exemptions are valid for a period of two years or until a
voluntary revocation is filed or the exemption is revoked by the Division.
Your contractor is requesting a permit under this workers' compensation exemption and has acknowledge that he or she will not use
day labor, part-time employees or subcontractors for your project. The contractor has provided an affidavit stating that he or she will
be the only person allowed to work on your project. In these circumstances, Miami Shores Village does not require verification of
workers' compensation insurance coverage from the contractor's company for day labor, part-time employees or subcontractors.
BY SIGNING BE OW v ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS
CONTENTS.
Signature:
Owner
State of Florida
County of Miami -Dade
The foregoing was acknowledge before me this day of �Z—�— , 26 1
By CoL l to rrirj
Notary:
SEAL:
\\>> 11 IIIIIIIII/
\\�,�� k1ih opaliy known to me or has produced
yew s>>
a§`ide atio.6
•zN o a'V�
.u, � I.Q=
06/
///: *
4///111110111 0\`\\\
Structural Calculations
551 NE 102nd Street
Miami Shores, FL
Table of Contents
Steel Beams 1-4
....
Steel Columns .5,7• • •
.
Footing
Steel Base Plate
•
.. .
•
• 8-9 •
•
•••• •tQ-I'i,
•••• • ••
Connection at Tie Beam .....A .12,16
••• ••
•
. •
• •
•
• •
•
•
• . •
• •
•• • •• • • •
�',4%
'�1. �F .. •.. %RIDA .••' 4,v`..
,'� °NAL E$ �000`
�- j1/Itip a i8
Carlos E. yos, P.E. FL 81268
9812 NW 9th CT. Plantation, FI
(954) 815 2941
`‘‘###GAa�OS. . 'io
`�• •` GENSF. �J''.•
•
o g 1268
1*!
N„
T..
STATEof i
. 0 •.
Steel Beam
Lic. # : KW-06011976
Description : W8X40 (14.33 ft Span)
CODE REFERENCES
Licensee i Hoyos Engineering, KW-06011976
Calculations per AISC 360-10, IBC 2015, ASCE 7-10
Load Combination Set : ASCE 7-10
Material Properties
Analysis Methodlllowable Strength Design
Beam Bracing Completely Unbraced
Bending Axis : Major Axis Bending
Fy : Steel Yield 50.0 ksi
E: Modulus : 29,000.0 ksi
0(0.309 L(0.41)
r " _._,
W8x40
Span = 14.330 ft
• •
• •
�fi�
••••.
•
•
•
••
•
•
•
•
•
• •
••
• •
•
•
Applied Loads
Beam self weight calculated and added to loading
Uniform Load : D = 0.3080, L = 0.410 klft, Tributary Width = 1.0 ft
DESIGN SUMMARY
Maximum Bending Stress Ratio =
Section used for this span
Ma : Applied
Mn / Omega : Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
0.196: 1
W8x40
19.457 k-ft
99.301 k-ft
+D+L+H
7.165ft
Span # 1
•
•
Service loads entered. Load FaCtBi% IPbe applied tot calculations.• • •
Maximum Shear Stress Ratio =
0.092 in Ratio =
0.092 in Ratio =
0.171 in Ratio =
0.000 in Ratio =
Section used for this span
Va : Applied
Vn/Omega : Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
• • • •
• •
• • • •
•
•• ••
•• •
• • •
•
• • • •
1,863 >=360
1,863 >=360
1008 >=180
0 <180
• • •
• •
• •
• • •
•• •
Desi ' OK
•
• •
• • • •
••
• 0.091 : 1 • I
8x40 •
••••5!431 k,•••I
•• 59.40 k.•••
•••+U-1i+H IJ
13.000 ft
Span # 1
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values
Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega
+D+H
Dsgn. L = 14.33 ft 1
+D+L+H
Dsgn. L = 14.33 ft 1
+D+Lr+H
Dsgn. L = 14.33 ft 1
+D+S+H
Dsgn. L = 14.33 ft 1
+D+0.750Lr+0.750L+H
Dsgn. L = 14.33 ft 1
+D+0.750L+0.750S+H
Dsgn. L = 14.33 ft 1
+D+0.60W+H
Dsgn. L = 14.33 ft 1
+D+0.70E+H
Dsgn. L = 14.33 ft 1
+D+0.750Lr+0.750L+0.450W+H
Dsgn. L = 14.33 ft 1
+D+0.750L+0.750S+0.450W+H
Dsgn. L = 14.33 ft 1
+D+0.750L+0.750S+0.5250E+H
Dsgn. L = 14.33 ft 1
+0.60D+0.60W+0.60H
Dsgn. L = 14.33 ft 1
0.090
0.196
0.090
0.090
0.169
0.169
0.090
0.090
0.169
0.169
0.169
0.054
0.042
0.091
0.042
0.042
0.079
0.079
0.042
0.042
0.079
0.079
0.079
0.025
8.93
19.46
8.93
8.93
16.83
16.83
8.93
8.93
16.83
16.83
16.83
5.36
8.93
19.46
8.93
8.93
16.83
16.83
8.93
8.93
16.83
16.83
16.83
5.36
165.83
165.83
165.83
165.83
165.83
165.83
165.83
165.83
165.83
165.83
165.83
165.83
99.30 1.14 1.00
99.30 1.141.00
99.30 1.14 1.00
99.30 1.14 1.00
99.30 1.14 1.00
99.30 1.141.00
99.30 1.14 1.00
99.30 1.14 1.00
99.30 1.14 1.00
99.30 1.14 1.00
99.30 1.14 1.00
99.30 1.14 1.00
2.49
5.43
2.49
2.49
4.70
4.70
2.49
2.49
4.70
4.70
4.70
1.50
89.10
89.10
89.10
89.10
89.10
89.10
89.10
89.10
89.10
89.10
89.10
89.10
59.40
59.40
59.40
59.40
59.40
59.40
59.40
59.40
59.40
59.40
59.40
59.40
1
Steel Beam
Lic`# : KW-06011976 .-'" ' r. Licensee : Hoyos Engineering, KW-06011976
Description : W8X40 (14.33 ft Span)
Load Combination
Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega
Summary of Moment Values
Summary of Shear Values
Max Stress Ratios
+0.60D+0.70E+0.60H
Dsgn. L = 14.33 ft 1 0.054 0.025 5.36
Overall Maximum Deflections
5.36 165.83 99.30 1.14 1.00 1.50 89.10 59.40
Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
+D+L+H
Vertical Reactions
Load Combination
1 0.1706 7.206
Support 1 Support 2
0.0000 0.000
Support notation : Far left is #' Values in KIPS
Overall MAXimum 5.431 5.431
Overall MINimum 1.496 1.496
+D+H 2.493 2.493
+D+L+H 5.431 5.431
+D+Lr+H 2.493 2.493
+D+S+H 2.493 2.493
+D+0.750Lr+0.750L+H 4.697 4.697
+D+0.750L+0.750S+H 4.697 4.697
+D+0.60W+H 2.493 2.493
+D+0.70E+H 2.493 2.493
+D+0.750Lr+0.750L+0.450W+H 4.697 4.697
+D+0.750L+0.750S+0.450W+H 4.697 4.697
+D+0.750L+0.750S+0.5250E+H 4.697 4.697
+0.60D+0.60W+0.60H 1.496 1.496
+0.60D+0.70E+0.60H 1.496 1.496
D Only 2.493 2.493
Lr Only
L Only 2.938 2.938
S Only
W Only
E Only
H Only
• • • •
• •
• • .•..
• • •
•• • .. •
• . •
• ..
•
•
•
•
• • •
.... •• •
. . •
• • • • • ••
... •
• •
•• •• ••
•
• . •
• • • •
. .
• • • • •
• • •
•• • •. • • •
•
•• •
2
Steel Beam
Lic. # : KW-06011976
Description : W8x40 (11.5 ft Span)
CODE REFERENCES
Licensee : Hoyos Engineering, KW-06011976
Calculations per AISC 360-10, IBC 2015, ASCE 7-10
Load Combination Set : ASCE 7-10
Material Properties
Analysis MethoiAllowable Strength Design
Beam Bracing Completely Unbraced
Bending Axis : Major Axis Bending
Fy : Steel Yield 50.0 ksi
E: Modulus : 29,000.0 ksi
D(1.7?) L(3) '
II
D(0.446) L(0.266)
n
�
-, : ,W
.,4, t
A,,,
�1 '14
r. -
•
W8x40
Span =11.50ft
•
•
• • • •
••
••••
l•••al
•
•
••
•
•
•
•• •
• •
•
Applied Loads
Beam self weight calculated and added to loading
Uniform Load : D = 0.4460, L = 0.2660 k/ft, Tributary Width = 1.0 ft
Point Load : D = 1.760, L = 3.0 k @ 4.250 ft
DESIGN SUMMARY
Maximum Bending Stress Ratio = 0.245: 1
Section used for this span W8x40
Ma : Applied 24.325 k-ft
Mn / Omega : Allowable 99.301 k-ft
Load Combination +D+L+H
Location of maximum on span 4.271 ft
Span # where maximum occurs Span # 1
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
Service loads entered. Load Factdte y,Mbe appericalculatlener • • •
Maximum Shear Stress Ratio =
Section used for this span
Va : Applied
Vn/Omega : Allowable
Load Combination
Location of maximum on span
Span # where maximum occurs
0.060 in Ratio =
0.060 in Ratio =
0.126 in Ratio =
0.000 in Ratio =
• • • •
• •
• • • •
• •
•• ••
•
2,287 >=360
2,287 >=360
1091 >=180
0 <180
•• • • •
• • •
•
• • • •
• •
•
• •
••
-Design OK' ,icx
• •
• • •
•• •
•
• 0.123:1• •
•.W8x40 ;•••�:
Z3 ••••25 k
59.40 k
+D+L+H
0.000 ft
Span # 1
Maximum Forces & Stresses for Load Combinations
Load Combination Max Stress Ratios Summary of Moment Values
Segment Length Span # M V Mmax + Mmax - Ma Max Mnx Mnx/Omega Cb Rm
+D+H
Dsgn. L = 11.50 ft 1
+D+L+H
Dsgn. L = 11.50 ft 1
+D+Lr+H
Dsgn. L = 11.50 ft 1
+D+S+H
Dsgn. L = 11.50 ft 1
+D+0.750Lr+0.750L+H
Dsgn. L = 11.50 ft 1
+D+0.750L+0.750S+H
Dsgn. L = 11.50 ft 1
+D+0.60W+H
Dsgn. L = 11.50 ft 1
+D+0.70E+H
Dsgn. L = 11.50 ft 1
+D+0.750Lr+0.750L+0.450 W +H
Dsgn. L = 11.50 ft 1
+D+0.750L+0.750S+0.450W+H
Dsgn. L = 11.50 ft 1
+D+0.750L+0.750S+0.5250E+H
0.123
0.245
0.123
0.123
0.214
0.214
0.123
0.123
0.214
0.214
0.066
0.123
0.066
0.066
0.109
0.109
0.066
0.066
0.109
0.109
12.21
24.33
12.21
12.21
21.30
21.30
12.21
12.21
21.30
21.30
12.21
24.33
12.21
12.21
21.30
21.30
12.21
12.21
21.30
21.30
165.83
165.83
165.83
165.83
165.83
165.83
165.83
165.83
165.83
165.83
Summary of Shear Values
Va Max VnxVnx/Omega
99.30 1.18 1.00
99.30 1.23 1.00
99.30 1.18 1.00
99.30 1.18 1.00
99.30 1.22 1.00
99.30 1.22 1.00
99.30 1.18 1.00
99.30 1.18 1.00
99.30 1.22 1.00
99.30 1.22 1.00
3.90
7.32
3.90
3.90
6.47
6.47
3.90
3.90
6.47
6.47
89.10
89.10
89.10
89.10
89.10
89.10
89.10
89.10
89.10
89.10
59.40
59.40
59.40
59.40
59.40
59.40
59.40
59.40
59.40
59.40
Steel Beam
Lic. # : KW-06011976
Description : W8x40 (11.5 ft Span)
Load Combination
Segment Length
Max Stress Ratios
Licensee : Hoyos Engineering, KW-06011976
Summary of Moment Values
Span # M V Mmax + Mmax - Ma Max
Dsgn. L = 11.50 ft 1 0.214 0.109 21.30
+0.60D+0.60W+0.60H
Dsgn. L = 11.50 ft 1 0.074 0.039 7.33
+0.60D+0.70E+0.60H
Dsgn. L = 11.50 ft 1 0.074 0.039 7.33
Overall Maximum Deflections
Load Combination Span Max. "-" Defl Location in Span
21.30
7.33
7.33
Summary of Shear Values
Mnx Mnx/Omega Cb Rm Va Max VnxVnx/Omega
165.83 99.30 1.22 1.00 6.47 89.10
165.83 99.30 1.18 1.00 2.34 89.10
165.83 99.30 1.18 1.00 2.34 89.10
Load Combination
+D+L+H 1
Vertical Reactions
Load Combination
0.1265
Support 1 Support 2
5.586
Support notation : Far left is #'
59.40
59.40
59.40
Max. "+" Defl Location in Span
0.0000 0.000
Values in KIPS
Overall MAXimum
Overall MINimum
+D+H
+D+L+H
+D+Lr+H
+D+S+H
+D+0.750Lr+0.750L+H
+D+0.750L+0.750S+H
+D+0.60W+H
+D+0.70E+H
+D+0.750Lr+0.750L+0.450W+H
+D+0.750L+0.750S+0.450W+H
+D+0.750L+0.750S+0.5250E+H
+0.60D+0.60W+0.60H
+0.60D+0.70E+0.60H
D Only
Lr Only
L Only
S Only
W Only
E Only
H Only
7.325
2.342
3.904
7.325
3.904
3.904
6.470
6.470
3.904
3.904
6.470
6.470
6.470
2.342
2.342
3.904
6.083
2.067
3.445
6.083
3.445
3.445
5.424
5.424
3.445
3.445
5.424
5.424
5.424
2.067
2.067
3.445
3.421 2.638
• • •.••
• • •
•• •
.••.
• .
.•••
• •
.. •.
• • •
•
• • •
•. •
•. •
• . •
• .•
•
••
•
.• • • •
•
• ..
..• •
• •
• •
•
. ••
•
.. .
• • •
•• •
•
•
•
4
Description : Steel Column
Code References
Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used : ASCE 7-10
General Information
Steel Section Name : HSS4x4x3/8
Analysis Method : Allowable Strength
Steel Stress Grade
Fy : Steel Yield 36.0 ksi
E : Elastic Bending Modulus 29,000.0 ksi
Applied Loads
Column self weight included : 259.050 lbs * Dead Load Factor
AXIAL LOADS .. .
Axial Load at 15.0 ft, D = 3.445, L = 2.638 k
DESIGN SUMMARY
Bending & Shear Check Results
PASS Max. Axial+Bending Stress Ratio =
Load Combination
Location of max.above base
At maximum location values are .. .
Pa : Axial
Pn / Omega : Allowably
Ma-x : Applied
Mn-x / Omega : Allowable
Ma-y : Applied
Mn-y / Omega : Allowable
PASS Maximum Shear Stress Ratii
Load Combination
Location of max.above base
At maximum location values are ...
Va : Applied
Vn / Omega : Allowable
Load Combination Results
Load Combination
+D+H
+D+L+H
+D+Lr+H
+D+S+H
+D+0.750Lr+0.750L+H
+D+0.750L+0.750S+H
+D+0.60W+H
+D+0.70E+H
+D+0.750Lr+0.750L+0.450W+H
+D+0.750L+0.750S+0.450W+H
+D+0.750L+0.750S+0.5250E+H
+0.60D+0.60W+0.60H
+0.60D+0.70E+0.60H
Maximum Reactions
;c• .,; Licensee : Hoyos Engineering, KW-06011976
Overall Column Height 15.0 ft
Top & Bottom Fixity Top & Bottom Pinned
Brace condition for deflection (buckling) along columns :
X-X (width) axis :
Lu for X-X Axis buckling : 15 ft, K = 1.0
Y-Y (depth) axis :
Lu for Y-Y Axis buckling : 15 ft, K = 1.0
0.1355 : 1
+D+L+H
0.0 ft
6.342 k
46.796 k
0.0 k-ft
11.479 k-ft
0.0 k-ft
11.479 k-ft
0.0 : 1
0.0 ft
0.0 k
0.0 k
Service loads entered. Load Factors will be applied for calculations.
• •
•
•• •
Maximum Load Reactions.
Top along X-X
Bottom along X-X
Top along Y-Y
Bottom along Y-Y
•
•
• • • •
••••
• •
••••
•• •
• • "•
••
• •
0.Qk •
•
0.t k• •
0.0• •
0. • •
••
•
� •
• •
•• ••
Maximum Load Deflections•.a • • •
Along Y-Y 0.0 in at•
for load combination : • •
• • •
Along X-X 0.0 in • at •
for load combination :
Maximum Axial + Bending Stress Ratios
Stress Ratio Status Location
0.079 PASS
0.136 PASS
0.079 PASS
0.079 PASS
0.121 PASS
0.121 PASS
0.079 PASS
0.079 PASS
0.121 PASS
0.121 PASS
0.121 PASS
0.047 PASS
0.047 PASS
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
Axial Reaction X-X Axis Reaction
Load Combination @ Base @ Base @ Top
+D+H 3.704
•
•
•
• •
• •
40.0 ft • above bay : •
• • •
•d0tt•above Base •
Maximum Shear Ratios
Stress Ratio Status Location
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
•• •
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
0.00 ft
Note: Only non -zero reactions are listed.
k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
@ Base @ Top @ Base @ Top @ Base @ Top
5
Steel Column
Lic. # : KW-06011976
Description : Steel Column
Maximum Reactions
Load Combination
w,;; Licensee : Hoyos Engineering, KW-06011976
Note: Only non -zero reactions are listed.
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End Moments k-ft My - End Moments
@ Base @ Base @ Top @ Base @ Top @ Base @ Top @ Base @ Top
+D+L+H 6.342
+D+Lr+H 3.704
+D+S+H 3.704
+D+0.750Lr+0.750L+H 5.683
+D+0.750L+0.750S+H 5.683
+D+0.60W+H 3.704
+D+0.70E+H 3.704
+D+0.750Lr+0.750L+0.450W+H 5.683
+D+0.750L+0.7505+0.450W+H 5.683
+D+0.750L+0.7505+0.5250E+H 5.683
+0.600+0.60W+0.60H 2.222
+0.60D+0.70E+0.60H 2.222
D Only 3.704
LrOnly ••••••
L Only 2.638 • • ••••
SOnly ••
..• •
W Only
E Only
H Only
Extreme Reactions • • • • • • • • •
•
Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx - End MOft�fits k-ft 'My'End Momenta • •
Item Extreme Value @ Base @ Base @ Top @ Base @ Top @ Base• • @• pop •@.Base @ Top: • • •
Axial @ Base Maximum 6.342 • • • • • •
•
Minimum . • • • •
Reaction, X-X Axis Base Maximum 3.704 : • •
• •
Minimum 3.704 • • • • •
Reaction, Y-Y Axis Base Maximum 3.704 • • •
•• • •• • • •
Minimum 3.704 • •••
Reaction, X-X Axis Top Maximum 3.704
Minimum 3.704
Reaction, Y-Y Axis Top Maximum 3.704
Minimum 3.704
Moment, X-X Axis Base Maximum 3.704
Minimum 3.704
Moment, Y-Y Axis Base Maximum 3.704
Minimum 3.704
Moment, X-X Axis Top Maximum 3.704
Minimum 3.704
Moment, Y-Y Axis Top Maximum 3.704
Minimum 3.704
Steel Section Properties : HSS4x4x3/8 Depth = 4.000 in I xx = 10.30 104 J = 17.500104
Design Thick = 0.349 in S xx = 5.13 inA3
Width = 4.000 in R xx = 1.470 in
Wall Thick = 0.375 in Zx = 6.390 in^3
Area = 4.780 i02 I yy = 10.300 in^4 C = 9.140 in^3
Weight = 17.270 pif S yy = 5.130 iO3
R yy = 1.470 in
•
•
••
• •
Ycg
0.000 in
•• •
• • •
• ••
•
Steel Column
Lic. # : KW-06011976 Y-a7 Licensee : Hoyos Engineering, KW-06011976
Description : Steel Column
Sketches
c
0
0
/Load 1
4.00in
x
•••w
• j;.
• • •••
• • •
•• • ••
• •
• •
•
•
••
•
• •
•••• •• • • •
• • •• •
• •
••••• • •
••
• •
•• ••
••• •
••
••
• •
• • •
• • •
• • •
•• •
•
•
• •
•• • • •
• • •
General Footing
Lic. #: KW-06011976
Description : 3'x3'x1' Concentric Loading
Code References
Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used : ASCE 7-10
General Information
Material Properties
Pc : Concrete 28 day strength
fy : Rebar Yield
Ec : Concrete Elastic Modulus
Concrete Density
tp Values Flexure
Shear
Analysis Settings
Min Steel % Bending Reinf.
Min Allow % Temp Reinf. _
Min. Overturning Safety Factor
Min. Sliding Safety Factor =
Add Ftg Wt for Soil Pressure
Use ftg wt for stability, moments & shears :
Add Pedestal Wt for Soil Pressure
Use Pedestal wt for stability, mom & shear :
Dimensions
Width parallel to X-X Axis =
Length parallel to Z-Z Axis =
Footing Thickness
Pedestal dimensions...
px : parallel to X-X Axis
pz : parallel to Z-Z Axis
Height
Rebar Centerline to Edge of Concrete...
at Bottom of footing =
Reinforcing
Bars parallel to X-X Axis
Number of Bars
Reinforcing Bar Size
Bars parallel to Z-Z Axis
Number of Bars
Reinforcing Bar Size
3.0 ksi
= 60.0 ksi
3,122.0 ksi
145.0 pcf
0.90
0.750
Licensee : Hoyos Engineering; KW-06011976
Soil Design Values
Allowable Soil Beari
Increase Bearing By Footing Weight
Soil Passive Resistance (for Sliding)
Soil/Concrete Friction Coeff.
2.0 ksf
= No
= 250.0 pcf
0.30
Increases based on footing Depth
Footing base depth below soil surface =
Allow press. increase per foot of depth =
0.00180 when footing base is below =
1.0 : 1
1.0 : 1 Increases based on footing plan dimension • • • •
Yes Allowable pressure increase per foot of depth • • • •
Yes
No
3.0 ft
3.0 ft
12.0 in
in
in
in
3.0 in
5.0
# 5
5.0
# 5
Bandwidth Distribution Check (ACI 15.4.4.2)
Direction Requiring Closer Separatio n/a
# Bars required within zone n/a
# Bars required on each side of zone n/a
Applied Loads
P : Column Load
OB : Overburden
M-xx
M-zz
V-x
V-z
D
Lr
No
• • •_
when max. length or width is great* than
•
•
• • • •
••••"
• •
•. •.
•'• • •.•
•
•
•
•
•
•• •
• • •
• ••
•
•
••
• ••
..• -
• •
•.
•
• •
•
• •. •
• • •
X •• •
z
7-0'
X.X Sec. Loa..
L S W E
3.445 2.638
1.0 ft
ksf
ft
ksf
ft
H
k
ksf
•
.•
•
•
•
•
• •
•
•
•
•
•
k-ft
k-ft
k
k
-
Description : 3'x3'xV Concentric Loading
DESIGN SUMMARY
Min. Ratio
Item
Applied
Capacity
Licensee : Hoyos Engineering, KW-06011976.
Design OK
Governing Load Combination
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
0.4105
n/a
n/a
n/a
n/a
n/a
0.05289
0.05289
0.05289
0.05289
0.07847
0.07847
0.07847
0.07847
0.1471
Detailed Results
Soil Bearing
Rotation Axis &
Load Combination...
X-X, +D+H
X-X, +D+L+H
X-X, +D+Lr+H
X-X, +D+S+H
X-X, +D+0.750Lr+0.750L+H
X-X, +D+0.750L+0.750S+H
X-X, +D+0.60W+H
X-X, +D+0.70E+H
X-X, +D+0.750Lr+0.750L+0.450V1
X-X, +D+0.750L+0.7505+0.450W
X-X, +D+0.750L+0.7505+0.5250E
X-X, +0.60D+0.60W+0.60H
X-X, +0.60D+0.70E+0.60H
Z-Z, +D+H
Z-Z, +D+L+H
Z-Z, +D+Lr+H
Z-Z, +D+S+H
Z-Z, +D+0.750Lr+0.750L+H
Z-Z, +D+0.750L+0.750S+H
Z-Z, +D+0.60W+H
Z-Z, +D+0.70E+H
Z-Z, +D+0.750Lr+0.750L+0.450V1
Z-Z, +D+0.750L+0.7505+0.450W
Z-Z, +D+0.750L+0.750S+0.5250E
Z-Z, +0.60D+0.60W+0.60H
Z-Z, +0.60D+0.70E+0.60H
Soil Bearing 0.8209 ksf
Overturning - X-X 0.0 k-ft
Overturning - Z-Z 0.0 k-ft
Sliding - X-X 0.0 k
Sliding - Z-Z 0.0 k
Uplift 0.0 k
Z Flexure (+X) 1.044 k-ft/ft
Z Flexure (-X) 1.044 k-ft/ft
X Flexure (+Z) 1.044 k-ft/ft
X Flexure (-Z) 1.044 k-ft/ft
1-way Shear (+X) 6.447 psi
1-way Shear (-X) 6.447 psi
1-way Shear (+Z) 6.447 psi
1-way Shear (-Z) 6.447 psi
2-way Punching 24.175 psi
Xecc Zecc
Gross Allowable (in)
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
2.0 ksf
0.0 k-ft
0.0 k-ft
0.0 k
0.0 k
0.0 k
19.747 k-ft/ft
19.747 k-ft/ft
19.747 k-ft/ft
19.747 k-ft/ft
82.158 psi
82.158 psi
82.158 psi
82.158 psi
164.317 psi
+D+L+H about Z-Z axis
No Overturning
No Overturning
No Sliding
No Sliding
No Uplift
+1.20D+0.50Lr+1.60L+1.60 H
+1.20D+0.50Lr+1.60L+1.60 H
+1.20D+0.50 Lr+1.60L+1.60H
+1.20 D+0.50Lr+1.60L+1.60H
+ 1.20 D+0.50 L r+ 1.60 L+ 1.60 H
+1.20D+0.50Lr+1.60L+1.60H
+1.20 D+0.50Lr+1.60L+1.60H
+1.20D+0.50Lr+. der+•1.60H
+1:20100.50Lr+162t!t!+1.60 H
•• • •• •
• • •
• •
••
•
•
• •
• • •
Actual Soil Bearing Stress � tion • • Actual / a ctr:
Bottom, -Z Top, +Z Left, "n.. J ght, +t • • • • Ra1lp• • •
0.5278 0.5278 rWa • • • • n/a. • • 0,2 ..'
0.8209 0.8209 Na'..' nn/a /a ••: 0 11
0.5278 0.5278
0.5278 0.5278 rola • • • n/a ' 0.264• •
0.7476 0.7476 rt/a • nl� • • • • 007.1• • •
0.7476 0.7476 Ma • n 0.374 •
0.5278 0.5278 ii/a.' : n/a • •• 0: ' •
0.5278 0.5278 n/a n!a • • 0.264 •
0.7476 0.7476 n/a ne' ' 0.374
0.7476 0.7476 n/a n/a 0.374
0.7476 0.7476 n/a n/a 0.374
0.3167 0.3167 n/a n/a 0.158
0.3167 0.3167 n/a n/a 0.158
n/a n/a 0.5278 0.5278 0.264
n/a n/a 0.8209 0.8209 0.411
n/a n/a 0.5278 0.5278 0.264
n/a n/a 0.5278 0.5278 0.264
n/a n/a 0.7476 0.7476 0.374
n/a n/a 0.7476 0.7476 0.374
n/a n/a 0.5278 0.5278 0.264
n/a n/a 0.5278 0.5278 0.264
n/a n/a 0.7476 0.7476 0.374
n/a n/a 0.7476 0.7476 0.374
n/a n/a 0.7476 0.7476 0.374
n/a n/a 0.3167 0.3167 0.158
n/a n/a 0.3167 0.3167 0.158
9
SteelBase. Plate
Lic. # : KW-06011976
Description: -None--
Code Reference
Licensee : Hoyos Engineering, KW-06011976;.
Calculations per AISC Design Guide # 1, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set : ASCE 7-10
General Information
Material Properties
AISC Design Method-oad Resistance Factor Design
Steel Plate Fy = 36.0 ksi
Concrete Support fc = 3.0 ksi
Assumed Bearing A' -ring Area = P / Fp
Column & Plate
c : LRFD Resistance Fac
Allowable Bearing Fp per J8
Column Properties
Steel Sectic HSS3-1/2x3-1/2x3/8
Depth 3.5 in
Width 3.5 in
Flange Thickne 0.349 in
Web Thickne 0 in
Plate Dimensions
N : Length 12.0 in
B : Width 12.0 in
Thickness 1.0 in
Column assumed welded to base
Area
Ixx
lyy
4.09 inA2
6.49 in^4
6.49 in^4
Support Dimensions
Width along "X"
Length along "Z'
36.0 in
36.0 in
Applied Loads
M-X
P-Y
V-Z
D : Dead Load 3.445 k 0.0 k
L : Live 2.638 k 0.0 k
Lr: Roof Live 0.0 k 0.0 k
S:Snow 0.0k 0.0k
W : Wind 0.0 k 0.0 k
E: Earthquake 0.0 k 0.0 k
H : Lateral Earth 0.0 k 0.0 k 0.0 k-ft a �,Z,r5-�, `i-Z;
" P " = Gravity load, "+" sign is downwil�" Moments create higher soil pressure at +Z ec,:. ,� a . u__..,a .-.-.ems--: ,t.
"+" Shears push plate towards +Z edge
0.60
5.10 ksi
3'-0"
Anchor Bolts
Anchor Bolt or Rod Description 3/4
Max of Tension or Pullout Capacity
Shear Capacity
Edge distance : bolt to plate
Number of Bolts in each Row
Number of Bolt Rows
0.0 k
0.0 k
1.250 in
2.0
1.0
0.0 k-ft
0.0 k-ft
0.0 k-ft
0.0 k-ft
0.0 k-ft
0.0k-ft
x
Cistanat
x
Cistance
/0
Steel Base Plate
Description : —None—
GOVERN/NG DESIGN LOAD CASE SUMMARY
Plate Design Summary
Design Method Load Resistance Factor Design
Governing Load Combinat +1.20D+0.50Lr+1.60L+1.60H
Axial Load Only
1'-0" x 1'-0" x 1"
8.355 k
0.000 k-ft
Goveming Load Case Typ
Design Plate Size
Pu : Axial
Mu : Moment
,, t " Licensee : Hoyos Engineering, KW-06011976
Mu : Max. Moment
fb : Max. Bending Stress
Fb : Allowable :
Fy* Phi
Bending Stress Rati
0.009 k-in
0.038 ksi
32.400 ksi
0.001
Bending Stress OK
fu : Max. Plate Bearing Stress ....
Fp : Allowable ;
min( 0.85*fc•sgrt(A2JA1), 1.7* fc)*Phi
Bearing Stress Ratic
0.522 ksi
3.060 ksi
0.171
Bearing Stress OK
• •
• . .
.• •
• • • •
•.••
• •
•. •.
• . .
• .
• •
• . .
•. •
• .••
• •
••.•
.• •
• • •
• .•
•
•. •
• . •
• •.
•.• •
• .
•
.. .
• . •
� •
•
• •
� •
•
•
11
www.hilti.us
Company:
Specifier.
Address:
Phone I Fax:
E-Mail:
Profis Anchor 2.7.6
Page:
Project
Sub -Project I Pos. No.:
Date:
2/22/2018
Specifier's comments:
1 Input data
Anchor type and diameter:
Effective embedment depth:
Material:
Evaluation Service Report:
Issued I Valid:
Proof.
Stand-off installation:
Anchor plate:
Profile:
Base material:
Reinforcement
Seismic loads (cat C, D, E, or F)
Geometry [in.] & Loading [lb, in.ib]
KWIK HUS-EZ (KH-EZ) 3/4 (4)
her = 2.920 in., hnom = 4.000 in.
Carbon Steel
ESR-3027
2/1/2016 112/1/2017
Design method ACI 318 / AC193
eb = 0.000 in. (no stand-off); t = 0.500 in.
Ix x ly x t = 6.500 in. x 16.375 in. x 0.500 in.; (Recommended plate thickness: not calculated
no profile • •
uncracked concrete, 3000, fc' = 3,000 psi; h = 420.000 in. • • •
tension: condition B, shear. condition B; no supplemental splitting reinforcemeltesent
edge reinforcement: none or < No. 4 bar
•••• •.
no .• • • •
• • • •
• •
•• ••
• • •
• •
• •
• • •
•• •
• •••
• •
• • • •
•• •
• • •
• ••
•
• ••
• • • •
• •
••
•
• •
•
•• •
• • •
••
•
•
•
•
•
•
•�
•
•
•
•
Input data and results must be checked for agreement with the existing conditions and for plausibility)
PROFIS Anchor (c) 2003-2009 Hilti AG, FL-9494 Schaan Hilt is a registered Trademark of Hilti AG, Schaan
12
www.hilti.us
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project
Sub -Project I Pos. No.:
Date:
2 Load case/Resulting anchor forces
Load case: Design loads
Anchor reactions [ib]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 0 679 679 0
2 0 679 679 0
3 0 679 679 0
4 0 679 679 0
5 0 679 679 0
6 0 679 679 0
7 0 679 679 0
8 0 679 679 0
max. concrete compressive strain: - (Tool
max. concrete compressive stress: - [Psi)
resulting tension force in (x/y)=(0.000/0.000): 0 [Ib]
resulting compression force in (x/y)=(0.000/0.000): 0 [Ib]
Profis Anchor 2.7.6
2
2/22/2018
05
03
A
06
0 4
01 02
07 08
• •
• • •
•• •
•
• • • •
••.•
•. •
• • •
• ••
•
•••• •• •
3 Tension Toad • • •• •
•••• • .•
Load N. (Ib] Capacity 4, N„ (Ib] Utilization 0,1 =4.4 dN, ys Sta•
Steel Strength* N/A N/A N/A • • • • N/A ' •'
Pullout Strength* N/A N/A N/A , • N/A •
Concrete Breakout Strength' N/A N/A N/A • � • Hi • : •
•
•
* anchor having the highest loading '*anchor group (anchors in tension) • • • • ••
•. •
• • •
Dx
� •
•
•
•
•
• •
•
•
•
Input data and results must be checked far agreement with the existing conditions and for plausibility)
PROFIS Anchor ( c) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
_Iriii.nr"
www.hilti.us
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project
Sub -Project I Pos. No.:
Date:
Profis Anchor 2.7.6
3
2/22/2018
4 Shear Toad
Load V. [Ib] Capacity $ Vn (Ib] Utilization pv = V„a/$ Vn Status
Steel Strength* 679 9,996 7 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength" 5,431 34,603 16 OK
Concrete edge failure in direction x+** 5,431 7,557 72 OK
anchor having the highest loading '"anchor group (relevant anchors)
4.1 Steel Strength
Vm = ESR value
4 Veteel a V.
Variables
/4•,v [in.2]
refer to ICC-ES ESR-3027
ACI 318-08 Eq. (D-2)
fut. [psi]
0.39 81,600
Calculations
Vsa [lb]
16,660
Results
V5. [Ib]
16,660
4) steel 0 V. [lb] V. [Ib]
0.600 9,996 679
4.2 Pryout Strength 11 VV.„— "W [(^nANCO) W ec,N Ai/ed.N W c.N W cp,N Nb]
Vcpg 2 Vua
AN, see ACI 318-08, Part D.5.2.1, Fig. RD.5.2.1(b)
ANm = 9 hBf
1
W ac,N = ( 2 eN) s 1.0
1+3hef
Wed,N=0.7+0.3 (Vet) 51.0
1.5haf
W cp,N =MAX(—! "'n, 1.511ef) 5 1.0
`9c CaC
Nb = Ito Vrc heir
Variables
k, p he [in.] ect,N [in.]
2 2.920 0.000
W c,N [in.] kc
1.000 4.410 27
Calculations
ANc [in.2]
261.12
Results
V.g [lb]
49,432
Awe [in.2] W eel,N
76.74 1.000
4) conaete 41 Vcpg [Ib]
0.700 34,603
ACI 318-08 Eq. (D-31)
ACI 318-08 Eq. (D-2)
ACI 318-08 Eq. (D-6)
ACI 318-08 Eq. (D-9)
ACI 318-08 Eq. (D-11)
ACI 318-08 Eq. (D-13)
ACI 318-08 Eq. (D-7)
ed,N [in.]
0.000
1
Ca,rrn [in]
4.250
fc [psi]
3,000
• •
• • •
•• •
•
. • ••
• •
• • • •
•• •
• • •
• ••
•
• • • • •• •
• • • • .
• • • • • ••
. •
•• ••
• • •
• •
• •
• • •
•• •
• • • •
• •
••
•
•
•
•• •
• • •
•• •
W ec2,N W ed,N W cp.N Nb [Ibl
1.000 0.991 0.993 7,379
Vua [Ib]
5,431
•
• .
•
•
• •
•
••
•
•
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c) 2003-2009 HMI AG, FL-9494 Schwan Hitt' is a registered Trademark of Hiltl AG, Schaan
/4
1!!IIn - r
www.hiltii.us
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Page:
Project
Sub -Project I Pos. No.:
Date:
Profis Anchor 2.7.6
4
2/22/2018
4.3 Concrete edge failure In direction x+
Avc
Vac -(Avg)Wec,vWed,vWevWh,vIv lamely Vb
Vcbg 2 Vue
Av, see ACI 318-08, Part D.6.2.1, Fig. RD.6.2.1(b)
Av�o =4.5c
1
_ ( 2e„)51.0
kVeaV 1 + 3cat
W ed,v = 0.7 + 0.00 5 1.0
h.v
1.5cat Z 1.0
W - ha
0
Vb = (7 (aa)2 NZ) f c;.5
Variables
cat [in.]
4.250
ACI 318-08 Eq. (D-22)
ACI 318-08 Eq. (D-2)
ACI 318-08 Eq. (D-23)
ACI 318-08 Eq. (D-26)
ACI 318-08 Eq. (D-28)
ACI 318-08 Eq. (D-29)
ACI 318-08 Eq. (D-24)
ca2 [in.] ecv [in.] W c,v
0.000 1.400
le [in.] da [in.] fb [psi]
2.920 1.000 0.750 3,000
Calculations
Avc [in.2] Avco [in.2] W ec,V W ed,V
164.16 81.28 1.000 1.000
Results
Vcbg [Ib] concrete 4) Vcbe [Ib] Vaa [Ib]
10,795 0.700 7,557 5,431
ha [in.]
420.000
W parellel.V
1.000
W h.V
1.000
• •
• • •
•• •
•
• •
• •
•• ••
Vb (14 • •
3,816" •
• •
• • •
•• •
••••
• •
•• •
• • •
• ••
•
•• •
• • •
• ••
• • • •
• •
••
•
•
•
•• •
• • .
•• •
5 Warnings
The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re -distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
• Condition A applies when supplementary reinforcement is used. Them factor is increased for non -steel Design Strengths except Pullout
Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout
Strength. Refer to your local standard.
• Refer to the manufacturer's product literature for cleaning and installation instructions.
• Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant
standard!
Fastening meets the design criteria!
•.
•
•
•
•
•
• •
•
••
•
•
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hllti AG, Schaan
'5
www.hilti.us
Company:
Specifier.
Address:
Phone I Fax:
E-Mail:
Page:
Project
Sub -Project I Pos. No.:
Date:
Profis Anchor 2.7.6
5
2/22/2018
6 Installation data
Anchor plate, steel: -
Profile: no profile
Hole diameter in the fixture: df = 0.875 in.
Plate thickness (input): 0.500 in.
Recommended plate thickness: not calculated
Drilling method: Hammer drilled
Cleaning: Manual leaning of the drilled hole according
Anchor type and diameter. KWIK HUS-EZ (KH-EZ) 3/4 (4)
Installation torque: 1,380.002 in.lb
Hole diameter in the base material: 0.750 in.
Hole depth in the base material: 4.375 in.
Minimum thickness of the base material: 6.000 in.
to instructions for use is required.
6.1 Recommended accessories -
Drilling Cleaning
• Suitable Rotary Hammer • Manual blow-out pump
• Properly sized drill bit
3.250
3.250
0 6
to
0
co
co
Setting
• Torque wrench
iri
0
0
co
CO
co
OD
CO
1.500
3.500
1.500
Coordinates Anchor in.
Anchor x y c-x c+x
1 -1.750 -2.500 4.250 7.750
2 1.750 -2.500 7.750 4.250
3 -1.750 2.500 4.250 7.750
4 1.750 2.500 7.750 4.250
c-y
c+y
• •
• • 9
•• •
•
• • • •
• •
• • • •
• •
•• ••
• • •
••
••
• • •
••
Anchor x y c.x c+x
5 -1.750 6.500 4.250 7.750
6 1.750 6.500 7.750 4.250
7 -1.750 -6.500 4.250 7.750
8 1.750 -6.500 7.750 4.250
c.y
• • ••
• •
• • • •
•• •
• • •
• ••
•
•• •
• • •
• ••
• • • •
• •
••
•
••
•
•• •
..
C+y
•'
•
•
•
•
•
• •
•
•
•
•
•
•
•
Input data and results must be checked for agreement with the existing conditions and for plausibility)
PROFIS Anchor (c) 2003.2009 Hilh AG, FL-9494 Schaan HUB is a registered Trademark of Hilti AG, Schwan
/c+
10050 N.E. 2nd Ave, Miami Shores, Florida 33138
Tel: 305-795-2204 Fax: 305-756-8972
Description: NEW CABINETS AND COUNTERTOPS, REMOVE WALL, FLOORING
551 NE 102 ST
Miami Shores , FL 331382454
If the building is located in a special flood hazard area documentation of the as -built lowest floor
elevation or lowest horizontal structural member has been provided and is retained in the records of
Miami Shores Village.
This certificate issued pursuant to the requirements of the Florida Building Code certifying that at the
time of issuance this structure was in compliance with the various ordinances of the jurisdiction
regulating building construction or use.
Not Transferable
POST IN A CONSPICUOUS PLACE
Miami Shores Viiiage
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
AZZTel: (305) 795.2204 Name: j An/ Fax: (305) 756.8972
Permit # 2/ `2 2 QC
Email: C,J/CfiZ-Z3 �j 4 ra JcemPhone # Z 3 5F PST-
CERTIFICATE OF OCCUPANCY/COMPLETION
CHECK LIST
Building permit card.
❑ Surveys (2 copies) Final as built - Required Items: Elevations of buildings showing all intended
setbacks from property lines and other existing structures. Ingress+ Egress, required parking
spaces, Wheel stops, stripping, and all paving to exterior.
❑ Certificate of Elevation — (Sealed by surveyor). Expiration date required on the form.
❑ Certificate of Insulation.
❑ Certificate of Soil Treatment (Final treatment -original)\
CHAPTER 2913-5 TERMITE PROTECTION: "This Building has received a complete treatment
for the prevention of subterranean termites. Treatment is in accordance with the rules and
law as established by the Florida Department of Agriculture and Consumer Services."
❑ Health Department Approval Letter (On septic or private water).
Note: If the house is on septic tank, approval letter is required from Health Dpt.
El Soil Compaction Letter (Density report is required)
❑ Final certification letter from the Engineer/Architect (on masonry, trusses, special structure, etc)
❑ Backflow preventor certificate (Required on commercial projects only)
❑ Declaration of use. (Recorded in Miami -Dade Clerk of Courts)
PLEASE NOTE THAT THE SAME ITEMS ARE REQUIRED FOR TEMPORARY CO
— • - -Emergency-C-& fWithortt 24-Hrs Processing-) AdditionaFfee-is $80.00.
• Temporary CO (Up to 90 days max) $75.00.
• Residential CO $150.00
• Residential CC $50.00
• Commercial CO and CC $200.00
Permit: 1201— 2..95
Miami Shores Viiiage
Building Department
E-mail:
Phone:
N\V1
❑ Building permit card.
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
CERTIFICATE OF OCCUPANCY/COMPLETION
CHECK LIST
❑ Surveys (2 copies) Final as built - Required Items: Elevations of buildings showing all intended
setbacks from property lines and other existing structures. Ingress+ Egress, required parking
spaces, Wheel stops, stripping, and all paving to exterior.
❑ Certificate of Elevation — (Sealed by surveyor). Expiration date required on the form.
❑ Certificate of Insulation.
❑ Certificate of Soil Treatment (Final treatment -original)\
CHAPTER 2913-5 TERMITE PROTECTION: "This Building has received a complete treatment
for the prevention of subterranean termites. Treatment is in accordance with the rules and
law as established by the Florida Department of Agriculture and Consumer Services."
❑ Health Department Approval Letter (On septic or private water).
Note: If the house is on septic tank, approval letter is required from Health Dpt.
❑ Soil Compaction Letter (Density report is required)
❑ Final certification letter from the Engineer/Architect (on masonry, trusses, special structure, etc)
❑ Backflow preventor certificate (Required on commercial projects only)
❑ Declaration of use. (Recorded in Miami -Dade Clerk of Courts)
PLEASE NOTE THAT THE SAME ITEMS ARE REQUIRED FOR TEMPORARY CO
• Emergency CO (Without 24 Hrs Processing) Additional fee is $80.00.
• Temporary CO (Up to 90 days max) $75.00. ''
• Residential CO $150.00 � � �
• Residential CC $50.00 ,9 S �`
• Commercial CO and CC $200.00 F,
r
<001
i i i
Miami Shores Village
Building Department
10050 NE 2 Ave
Miami Shores FL 33138
Issue Date: 3/6/2018
it NO. RC 12-1F7.295
fiype: 3u(Id(ng (Residential)
Wort class:'Atteratlon
Permit Status: 'ApprOved
Expires: 01/16/2019
INSPECTION REQUESTS: (305)762-4949 or log on at https://bldg.msvfl.gov energov_prod/selfservice
Requests must be received by 3:30pm
WORK IS ALLOWED: MONDAY THROUGH FRIDAY, 8:OOAM - 7:OOPM
SATURDAY 8:OOAM - 6:OOPM.
NO WORK IS ALLOWED ON SUNDAY OR HOLIDAYS
BUILDING AND ROOFING INSPECTIONS ARE DONE MONDAYTHROUGH FRIDAY .
NO INSPECTION WILL BE MADE UNLESS THE PERMIT CARD IS DISPLAYED AND HAS BEEN APPROVED . PLANS ARE
READILY AVAILABLE . IT IS THE PERMIT APPLICANT'S RESPONSIBILITY TO ENSURE THAT WORK IS ACCESSIBLE AND
EXPOSED FOR INSPECTION PURPOSES. NEITHER THE BUILDING OFFICIAL NOR THE CITY SHALL BE LIABLE FOR
EXPENSE ENTAILED IN THE REMOVAL OR REPLACEMENT OF ANY MATERIAL REQUIRED TO ALLOW INSPECTION .
POST ON SITE
1132060170980
1
Owner's Name: CORY & LISA GITTNER
Job Address: 551 NE 102 ST
Miami Shores , FL 33138-2454
Owner's Phone:
Total Square Feet: 250
rotal Job Valuation : $ 30,000.00
Contractor(s)
WILCON CO
Phone
(786)399-8855
Address
9636 NE 5 AVE, MIAMI SHORES, FL 33138
Description: NEW CABINETS AND COUNTERTOPS, REMOVE WALL, FLOORING
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS
TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED
AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF
COMMENCEMENT.
Page 1 of 1
INSPECTION RECORD
Foundation
Stemwall
Slab
Columns (1st Lift)
Columns (2nd Lift)
Tie Beam
Truss/Rafters
Roof Sheathing
Bucks
Interior Framing
Insulation
Ceiling Grid
Drywall
Firewall
Wire Lath
Pool Steel
Pool Deck
Final Pool
Final Fence
Screen Enclosure
Driveway
Driveway Base
Tin Cap
Roof in Progress
Mop in Progress
Final Roof
Shutters Attachment
Final Shutters
Rails and Guardrails
ADA compliance
FINAL
DOCUMENTS
Soil Bearing Cert
Soil Treatment Cert
Floor Elevation Survey
Reinf Unit Mas Cert
Insulation Certificate
Spot Survey
Final Survey
Truss Certification
STRUCTURAL COMMENTS
WINDOWS & DOORS
INSPECTION DATE INSP
Attachment
FINAL
PUBLIC WORKS
INSPECTION
DATE
INSP
Excavation
ANAL
ELECTRICAL
INSPECTION
DATE
INSP
Temporary Pole
30 Day Temporary
Pool Bonding
Pool Deck Bonding
Pool Wet Niche
Underground
Footer Ground
Slab
Wall Rough
Ceiling Rough
Rough
Telephone Rough
Telephone Final
TV Rough
TV Final
Cable Rough
Cable Final
Intercom Rough
Intercom Final
Alarm Rough
Alarm Final
Fire Alarm Rough
Fire Alarm Final
Service Work With
FINAL
ELECTRICAL
COMMENTS
INSPECTION DATE INSP
Final Sprinkler
Final Alarm
FINAL
Rough
Water Service
2nd Rough
Top Out
Fire Sprinklers
Septic Tank
Sewer Hook-up
Roof Drains
Gas
LP Tank
Well
Lawn Sprinklers
Main Drain
Pool Piping
Backflow Preventor
Interceptor
Catch Basins
Condensate Drains
HRS Final
FINAL
PLUMBING COMMENTS
Ventilation Rough
Hood Rough
Pressure Test
Final Hood
Final Ventilation
Final Pool Heater
Final Vacuum
FINAL
MECHANICAL COMMENTS